1
|
Park SY, Trinh KTL, Song YJ, Lee NY. Pipette-free field-deployable molecular diagnostic kit for bimodal visual detection of infectious RNA viruses. Biotechnol J 2024; 19:e2300521. [PMID: 38403439 DOI: 10.1002/biot.202300521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 12/22/2023] [Accepted: 01/08/2024] [Indexed: 02/27/2024]
Abstract
Here, we developed a field-deployable molecular diagnostic kit for the detection of RNA viruses that operates in a pipette-free manner. The kit is composed of acrylic sticks, PCR tubes, and palm-sized three-dimensional(3D)-printed heaters operated by batteries. The kit performs RNA extraction, reverse transcriptase loop-mediated isothermal amplification (RT-LAMP), and visual detection in one kit. An acrylic stick was engraved with one shallow and one deep cylindrical chamber at each end for the insertion of an FTA card and ethidium homodimer-1 (EthD-1), respectively, to perform RNA extraction/purification and bimodal visual detection of the target amplicons. First, an intercalation of EthD-1 into the target DNA initially produces fluorescence upon UV illumination. Next, the addition of a strong oxidant, in this case sodium (meta) periodate (NaIO4 ), produces intense aggregates in the presence of EthD-1-intercalated DNA, realized by electrostatic interaction. In the absence of the target amplicon, no fluorescence or aggregates are observed. Using this kit, two major infectious viruses-severe fever with thrombocytopenia syndrome virus (SFTSV) and severe acute respiratory syndrome coronavirus (SARS-CoV-2)-were successfully detected in 1 h, and the limits of detection (LOD) were approximately 1 virus μL-1 for SFTSV and 103 copies μL-1 for SARS-CoV-2 RNA. The introduced kit is portable, end-user-friendly, and can be operated in a pipette-free manner, paving the way for simple and convenient virus detection in resource-limited settings.
Collapse
Affiliation(s)
- So Yeon Park
- Department of BioNano Technology, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea
| | - Kieu The Loan Trinh
- BioNano Applications Research Center, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea
| | - Yoon-Jae Song
- Department of Life Science, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea
| |
Collapse
|
2
|
Cerda A, Rivera M, Armijo G, Ibarra-Henriquez C, Reyes J, Blázquez-Sánchez P, Avilés J, Arce A, Seguel A, Brown AJ, Vásquez Y, Cortez-San Martín M, Cubillos FA, García P, Ferres M, Ramírez-Sarmiento CA, Federici F, Gutiérrez RA. An Open One-Step RT-qPCR for SARS-CoV-2 detection. PLoS One 2024; 19:e0297081. [PMID: 38271448 PMCID: PMC10810446 DOI: 10.1371/journal.pone.0297081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 12/26/2023] [Indexed: 01/27/2024] Open
Abstract
The COVID-19 pandemic has resulted in millions of deaths globally, and while several diagnostic systems were proposed, real-time reverse transcription polymerase chain reaction (RT-PCR) remains the gold standard. However, diagnostic reagents, including enzymes used in RT-PCR, are subject to centralized production models and intellectual property restrictions, which present a challenge for less developed countries. With the aim of generating a standardized One-Step open RT-qPCR protocol to detect SARS-CoV-2 RNA in clinical samples, we purified and tested recombinant enzymes and a non-proprietary buffer. The protocol utilized M-MLV RT and Taq DNA pol enzymes to perform a Taqman probe-based assay. Synthetic RNA samples were used to validate the One-Step RT-qPCR components, demonstrating sensitivity comparable to a commercial kit routinely employed in clinical settings for patient diagnosis. Further evaluation on 40 clinical samples (20 positive and 20 negative) confirmed its comparable diagnostic accuracy. This study represents a proof of concept for an open approach to developing diagnostic kits for viral infections and diseases, which could provide a cost-effective and accessible solution for less developed countries.
Collapse
Affiliation(s)
- Ariel Cerda
- ANID—Millennium Science Initiative Program—Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- FONDAP Center for Genome Regulation, Departamento de Genética Molecular y Microbiología, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Maira Rivera
- ANID—Millennium Science Initiative Program—Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Grace Armijo
- ANID—Millennium Science Initiative Program—Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- FONDAP Center for Genome Regulation, Departamento de Genética Molecular y Microbiología, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Catalina Ibarra-Henriquez
- ANID—Millennium Science Initiative Program—Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- FONDAP Center for Genome Regulation, Departamento de Genética Molecular y Microbiología, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Javiera Reyes
- ANID—Millennium Science Initiative Program—Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Paula Blázquez-Sánchez
- ANID—Millennium Science Initiative Program—Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Javiera Avilés
- ANID—Millennium Science Initiative Program—Millennium Institute for Integrative Biology (iBio), Santiago, Chile
| | - Aníbal Arce
- ANID—Millennium Science Initiative Program—Millennium Institute for Integrative Biology (iBio), Santiago, Chile
| | - Aldo Seguel
- ANID—Millennium Science Initiative Program—Millennium Institute for Integrative Biology (iBio), Santiago, Chile
| | - Alexander J. Brown
- Department of Biomedical Research, National Jewish Health, Denver, CO, United States of America
- Department of Immunology & Microbiology, University of Colorado Anschutz Medical Campus, Aurora, CO, United States of America
| | - Yesseny Vásquez
- Escuela de Ciencias Médicas, Facultad de Medicina, Universidad de Santiago de Chile, USACH, Santiago, Chile
| | - Marcelo Cortez-San Martín
- Departamento de Biología, Facultad de Química y Biología, Universidad de Santiago de Chile, USACH, Santiago, Chile
| | - Francisco A. Cubillos
- ANID—Millennium Science Initiative Program—Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- Departamento de Biología, Facultad de Química y Biología, Universidad de Santiago de Chile, USACH, Santiago, Chile
| | - Patricia García
- Departamento de Laboratorios Clínicos, Escuela de Medicina, Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Marcela Ferres
- Departamento de Laboratorios Clínicos, Escuela de Medicina, Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - César A. Ramírez-Sarmiento
- ANID—Millennium Science Initiative Program—Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Fernán Federici
- ANID—Millennium Science Initiative Program—Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- FONDAP Center for Genome Regulation, Departamento de Genética Molecular y Microbiología, Pontificia Universidad Católica de Chile, Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Rodrigo A. Gutiérrez
- ANID—Millennium Science Initiative Program—Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- FONDAP Center for Genome Regulation, Departamento de Genética Molecular y Microbiología, Pontificia Universidad Católica de Chile, Santiago, Chile
| |
Collapse
|
3
|
Amaral C, Pimentel C. Direct Detection of SARS-CoV-2 RNA in Saliva with Colorimetric RT-LAMP. Methods Mol Biol 2024; 2822:39-50. [PMID: 38907910 DOI: 10.1007/978-1-0716-3918-4_4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/24/2024]
Abstract
RT-LAMP is an effective alternative to RT-PCR-based diagnostics, offering high specificity, sensitivity, and rapid results. One notable advantage is the robustness of its enzymes, allowing for direct amplification from crude samples without the need for prior isolation of RNA. Colorimetric LAMP is particularly attractive as it eliminates the need for complex instrumentation, making it suitable for point-of-care applications. Here, we present a comprehensive step-by-step protocol for establishing an RT-LAMP-based test for direct detection of SARS-CoV-2 genomic RNA in saliva samples using different colorimetric detection methods. Importantly, this versatile test can be easily adapted to detect emerging pathogens.
Collapse
Affiliation(s)
- Catarina Amaral
- Instituto de Tecnologia Química e Biológica António Xavier, Universidade Nova de Lisboa, Oeiras, Portugal
| | - Catarina Pimentel
- Instituto de Tecnologia Química e Biológica António Xavier, Universidade Nova de Lisboa, Oeiras, Portugal.
| |
Collapse
|
4
|
de Souza LR, da Silva IEP, Celis-Silva G, Raddatz BW, Imamura LM, Kim EYS, Valderrama GV, Riedi HDP, Rogal SR, de Almeida BMM, Figueredo MVM, Bengtson MH, Massirer KB. Improved protocol for Bst polymerase and reverse transcriptase production and application to a point-of-care diagnostics system. Exp Biol Med (Maywood) 2023; 248:1671-1683. [PMID: 38088106 PMCID: PMC10723028 DOI: 10.1177/15353702231215815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2023] Open
Abstract
The pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has raised awareness in the scientific community about the importance of being prepared for sanitary emergencies. Many measures implemented during the COVID pandemic are now being expanded to other applications. In the field of molecular and immunological diagnostics, the need to massively test the population worldwide resulted in the application of a variety of methods to detect viral infection. Besides gold standard reverse transcription quantitative polymerase chain reaction (RT-qPCR), the use of reverse transcription loop-mediated isothermal amplification (RT-LAMP) arose as an alternative and sensitive method to amplify and detect viral genetic material. We have used openly available protocols and have improved the protein production of RT-LAMP enzymes Bst polymerase and HIV-reverse transcriptase. To optimize enzyme production, we tested different protein tags, and we shortened the protein purification protocol, resulting in reduced processing time and handling of the enzymes and, thus, preserved the protein activity with high purity. The enzymes showed significant stability at 4 °C and 25 °C, over 60 days, and were highly reliable when used as a one-step RT-LAMP reaction in a portable point-of-care device with clinical samples. The enzymes and the reaction setup can be further expanded to detect other infectious diseases agents.
Collapse
Affiliation(s)
- Lucas Rodrigo de Souza
- Center for Molecular Biology and Genetic Engineering (CBMEG), Universidade Estadual de Campinas (UNICAMP), Campinas/SP 13083-875, Brazil
- Center for Medicinal Chemistry (CQMED), Universidade Estadual de Campinas (UNICAMP), Campinas/SP 13083-886, Brazil
| | - Italo Esposti Poly da Silva
- Center for Molecular Biology and Genetic Engineering (CBMEG), Universidade Estadual de Campinas (UNICAMP), Campinas/SP 13083-875, Brazil
- Center for Medicinal Chemistry (CQMED), Universidade Estadual de Campinas (UNICAMP), Campinas/SP 13083-886, Brazil
- Department of Biochemistry and Tissue Biology, Institute of Biology, Universidade Estadual de Campinas (UNICAMP), Campinas/SP 13083-862, Brazil
| | - Gabriele Celis-Silva
- Center for Molecular Biology and Genetic Engineering (CBMEG), Universidade Estadual de Campinas (UNICAMP), Campinas/SP 13083-875, Brazil
- Center for Medicinal Chemistry (CQMED), Universidade Estadual de Campinas (UNICAMP), Campinas/SP 13083-886, Brazil
| | | | | | | | - Gabriel Vieira Valderrama
- Center for Molecular Biology and Genetic Engineering (CBMEG), Universidade Estadual de Campinas (UNICAMP), Campinas/SP 13083-875, Brazil
- Center for Medicinal Chemistry (CQMED), Universidade Estadual de Campinas (UNICAMP), Campinas/SP 13083-886, Brazil
| | | | | | | | | | - Mario Henrique Bengtson
- Center for Medicinal Chemistry (CQMED), Universidade Estadual de Campinas (UNICAMP), Campinas/SP 13083-886, Brazil
- Department of Biochemistry and Tissue Biology, Institute of Biology, Universidade Estadual de Campinas (UNICAMP), Campinas/SP 13083-862, Brazil
| | - Katlin Brauer Massirer
- Center for Molecular Biology and Genetic Engineering (CBMEG), Universidade Estadual de Campinas (UNICAMP), Campinas/SP 13083-875, Brazil
- Center for Medicinal Chemistry (CQMED), Universidade Estadual de Campinas (UNICAMP), Campinas/SP 13083-886, Brazil
| |
Collapse
|
5
|
Liu Y, Kumblathan T, Tao J, Xu J, Feng W, Xiao H, Hu J, Huang CV, Wu Y, Zhang H, Li XF, Le XC. Recent advances in RNA sample preparation techniques for the detection of SARS-CoV-2 in saliva and gargle. Trends Analyt Chem 2023; 165:117107. [PMID: 37317683 PMCID: PMC10204347 DOI: 10.1016/j.trac.2023.117107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Revised: 05/19/2023] [Accepted: 05/19/2023] [Indexed: 06/16/2023]
Abstract
Molecular detection of SARS-CoV-2 in gargle and saliva complements the standard analysis of nasopharyngeal swabs (NPS) specimens. Although gargle and saliva specimens can be readily obtained non-invasively, appropriate collection and processing of gargle and saliva specimens are critical to the accuracy and sensitivity of the overall analytical method. This review highlights challenges and recent advances in the treatment of gargle and saliva samples for subsequent analysis using reverse transcription polymerase chain reaction (RT-PCR) and isothermal amplification techniques. Important considerations include appropriate collection of gargle and saliva samples, on-site inactivation of viruses in the sample, preservation of viral RNA, extraction and concentration of viral RNA, removal of substances that inhibit nucleic acid amplification reactions, and the compatibility of sample treatment protocols with the subsequent nucleic acid amplification and detection techniques. The principles and approaches discussed in this review are applicable to molecular detection of other microbial pathogens.
Collapse
Affiliation(s)
- Yanming Liu
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
| | - Teresa Kumblathan
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
| | - Jeffrey Tao
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
| | - Jingyang Xu
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
| | - Wei Feng
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
| | - Huyan Xiao
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
| | - Jianyu Hu
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
| | - Camille V Huang
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
| | - Yiping Wu
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
| | - Hongquan Zhang
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
| | - Xing-Fang Li
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
| | - X Chris Le
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, T6G 2G3, Canada
| |
Collapse
|
6
|
Cabral KMDS, Baptista RCG, Castineiras TMPP, Tanuri A, Carneiro FA, Almeida MDS, Montero-Lomeli M. Accuracy of a raw saliva-based COVID-19 RT-LAMP diagnostic assay. Braz J Infect Dis 2023; 27:102790. [PMID: 37478898 PMCID: PMC10391658 DOI: 10.1016/j.bjid.2023.102790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 06/02/2023] [Accepted: 07/04/2023] [Indexed: 07/23/2023] Open
Abstract
The Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) pandemic demanded rapid diagnosis to isolate new COVID-19 cases and prevent disease transmission. Quantitative Real-Time Polymerase Chain Reaction (qRT-PCR) rapidly became the gold standard for diagnosis. However, due to the high cost and delay of the results, other types of diagnosis were implemented, such as COVID-19 Ag Rapid Tests and Reverse Transcription Technique followed by Loop-Mediated isothermal Amplification (RT-LAMP). In this work, we validated the use of RT-LAMP in saliva samples rather than nasopharyngeal swabs, as the collection is more comfortable. First, we selected 5 primer sets based on the limit of detection for SARS-CoV-2 RNA, then validated their sensitivity and specificity in patient samples. A total of 117 samples were analyzed by fluorometric RT-LAMP and compared with qRT-PCR results. Our results show that the use of a high-sensitive primer ORF1-a, together with a low-sensitive primer set Gene E (time to threshold of 22.9 and 36.4 minutes, respectively, using 200 copies of viral RNA), achieved sensitivity in purified RNA from saliva samples of 95.2% (95% CI 76.1‒99.8) with 90.5% specificity (95% CI 69.6‒98.8) (n = 42).As RNA purification increases the turnaround time, we tested the outcome of RT-LAMP utilizing raw saliva samples without purification. The test achieved a sensitivity of 81.8% (95% CI 59.7‒94.8) and a specificity of 90.9% (95% CI 70.8‒98.8). As a result, the accuracy of 92.9% (95% CI 80.5‒98.5) in purified RNA-saliva samples was lowered to an acceptable level of 86.4% (95% CI 72.6‒94.8) in raw saliva. Although mass vaccination has been implemented, new strains and low vaccination progress helped to spread COVID-19. This study shows that it is feasible to track new COVID-19 cases in a large population with the use of raw saliva as sample in RT-LAMP assay which yields accurate results and offers a less invasive test.
Collapse
Affiliation(s)
- Kátia Maria Dos Santos Cabral
- Universidade Federal do Rio de Janeiro (UFRJ), Instituto de Bioquímica Médica-Leopoldo de Meis, Rio de Janeiro, RJ, Brazil; Centro Nacional de Biologia Estrutural e Bioimagem, Plataforma Avançada de Biomoléculas, Rio de Janeiro, RJ, Brazil
| | - Ramon Cid Gismonti Baptista
- Universidade Federal do Rio de Janeiro (UFRJ), Instituto de Bioquímica Médica-Leopoldo de Meis, Rio de Janeiro, RJ, Brazil
| | | | - Amilcar Tanuri
- Universidade Federal do Rio de Janeiro (UFRJ), Instituto de Biologia, Departamento de Genética, Rio de Janeiro, RJ, Brazil
| | - Fabiana Avila Carneiro
- Centro de Pesquisa de Medicina de Precisão, Instituto de Biofísica Carlos Chagas Filho, Rio de Janeiro, RJ, Brazil; Núcleo de Pesquisa (Numpex-Bio), Campus Duque de Caxias Professor Geraldo Cidade, Duque de Caxias, RJ, Brazil
| | - Marcius da Silva Almeida
- Universidade Federal do Rio de Janeiro (UFRJ), Instituto de Bioquímica Médica-Leopoldo de Meis, Rio de Janeiro, RJ, Brazil; Centro Nacional de Biologia Estrutural e Bioimagem, Plataforma Avançada de Biomoléculas, Rio de Janeiro, RJ, Brazil
| | - Monica Montero-Lomeli
- Universidade Federal do Rio de Janeiro (UFRJ), Instituto de Bioquímica Médica-Leopoldo de Meis, Rio de Janeiro, RJ, Brazil.
| |
Collapse
|
7
|
Gao L, Li L, Fang B, Fang Z, Xiang Y, Zhang M, Zhou J, Song H, Chen L, Li T, Xiao H, Wan R, Jiang Y, Peng H. Carryover Contamination-Controlled Amplicon Sequencing Workflow for Accurate Qualitative and Quantitative Detection of Pathogens: a Case Study on SARS-CoV-2. Microbiol Spectr 2023; 11:e0020623. [PMID: 37098913 PMCID: PMC10269707 DOI: 10.1128/spectrum.00206-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Accepted: 04/02/2023] [Indexed: 04/27/2023] Open
Abstract
Carryover contamination during amplicon sequencing workflow (AMP-Seq) put the accuracy of the high-throughput detection for pathogens at risk. The purpose of this study is to develop a carryover contaminations-controlled AMP-Seq (ccAMP-Seq) workflow to enable accurate qualitative and quantitative detection for pathogens. By using the AMP-Seq workflow to detect SARS-CoV-2, Aerosols, reagents and pipettes were identified as potential sources of contaminations and ccAMP-Seq was then developed. ccAMP-Seq used filter tips and physically isolation of experimental steps to avoid cross contamination, synthetic DNA spike-ins to compete with contaminations and quantify SARS-CoV-2, dUTP/uracil DNA glycosylase system to digest the carryover contaminations, and a new data analysis procedure to remove the sequencing reads from contaminations. Compared to AMP-Seq, the contamination level of ccAMP-Seq was at least 22-folds lower and the detection limit was also about an order of magnitude lower-as low as one copy/reaction. By testing the dilution series of SARS-CoV-2 nucleic acid standard, ccAMP-Seq showed 100% sensitivity and specificity. The high sensitivity of ccAMP-Seq was further confirmed by the detection of SARS-CoV-2 from 62 clinical samples. The consistency between qPCR and ccAMP-Seq was 100% for all the 53 qPCR-positive clinical samples. Seven qPCR-negative clinical samples were found to be positive by ccAMP-Seq, which was confirmed by extra qPCR tests on subsequent samples from the same patients. This study presents a carryover contamination-controlled, accurate qualitative and quantitative amplicon sequencing workflow that addresses the critical problem of pathogen detection for infectious diseases. IMPORTANCE Accuracy, a key indicator of pathogen detection technology, is compromised by carryover contamination in the amplicon sequencing workflow. Taking the detection of SARS-CoV-2 as case, this study presents a new carryover contamination-controlled amplicon sequencing workflow. The new workflow significantly reduces the degree of contamination in the workflow, thereby significantly improving the accuracy and sensitivity of the SARS-CoV-2 detection and empowering the ability of quantitative detection. More importantly, the use of the new workflow is simple and economical. Therefore, the results of this study can be easily applied to other microorganism, which has great significance for improving the detection level of microorganism.
Collapse
Affiliation(s)
- Lifen Gao
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Lun Li
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Bin Fang
- Hubei Provincial Centers for Disease Control and Prevention, Wuhan, Hubei, People’s Republic of China
| | - Zhiwei Fang
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Yanghai Xiang
- Yueyang Central Hospital, Yueyang, Hunan, People’s Republic of China
| | - Min Zhang
- Yueyang Central Hospital, Yueyang, Hunan, People’s Republic of China
| | - Junfei Zhou
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Huiyin Song
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Lihong Chen
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Tiantian Li
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Huafeng Xiao
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Renjing Wan
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
| | - Yongzhong Jiang
- Hubei Provincial Centers for Disease Control and Prevention, Wuhan, Hubei, People’s Republic of China
| | - Hai Peng
- Institute for Systems Biology, Jianghan University, Wuhan, Hubei, People’s Republic of China
- Mingliao Biotechnology Co., Ltd., Wuhan, Hubei, People’s Republic of China
| |
Collapse
|
8
|
Szobi A, Buranovská K, Vojtaššáková N, Lovíšek D, Özbaşak HÖ, Szeibeczederová S, Kapustian L, Hudáčová Z, Kováčová V, Drobná D, Putaj P, Bírová S, Čirková I, Čarnecký M, Kilián P, Jurkáček P, Čabanová V, Boršová K, Sláviková M, Vaňová V, Klempa B, Čekan P, Paul ED. Vivid COVID-19 LAMP is an ultrasensitive, quadruplexed test using LNA-modified primers and a zinc ion and 5-Br-PAPS colorimetric detection system. Commun Biol 2023; 6:233. [PMID: 36864129 PMCID: PMC9979146 DOI: 10.1038/s42003-023-04612-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 02/20/2023] [Indexed: 03/04/2023] Open
Abstract
Sensitive and rapid point-of-care assays have been crucial in the global response to SARS-CoV-2. Loop-mediated isothermal amplification (LAMP) has emerged as an important diagnostic tool given its simplicity and minimal equipment requirements, although limitations exist regarding sensitivity and the methods used to detect reaction products. We describe the development of Vivid COVID-19 LAMP, which leverages a metallochromic detection system utilizing zinc ions and a zinc sensor, 5-Br-PAPS, to circumvent the limitations of classic detection systems dependent on pH indicators or magnesium chelators. We make important strides in improving RT-LAMP sensitivity by establishing principles for using LNA-modified LAMP primers, multiplexing, and conducting extensive optimizations of reaction parameters. To enable point-of-care testing, we introduce a rapid sample inactivation procedure without RNA extraction that is compatible with self-collected, non-invasive gargle samples. Our quadruplexed assay (targeting E, N, ORF1a, and RdRP) reliably detects 1 RNA copy/µl of sample (=8 copies/reaction) from extracted RNA and 2 RNA copies/µl of sample (=16 copies/reaction) directly from gargle samples, making it one of the most sensitive RT-LAMP tests and even comparable to RT-qPCR. Additionally, we demonstrate a self-contained, mobile version of our assay in a variety of high-throughput field testing scenarios on nearly 9,000 crude gargle samples. Vivid COVID-19 LAMP can be an important asset for the endemic phase of COVID-19 as well as preparing for future pandemics.
Collapse
Affiliation(s)
- Adrián Szobi
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Katarína Buranovská
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Nina Vojtaššáková
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Daniel Lovíšek
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Halil Önder Özbaşak
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Sandra Szeibeczederová
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Liudmyla Kapustian
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Zuzana Hudáčová
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
- Stanford University, 730 Escondido Rd., Stanford, CA, 94305, USA
| | - Viera Kováčová
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
- University of Cologne, Institute for Biological Physics, Zülpicher Str. 77, 50937, Köln, Germany
| | - Diana Drobná
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Piotr Putaj
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Stanislava Bírová
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Ivana Čirková
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Martin Čarnecký
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Peter Kilián
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Peter Jurkáček
- AstonITM s.r.o., Račianska 153, 831 54, Bratislava, Slovakia
| | - Viktória Čabanová
- Biomedical Research Center, Slovak Academy of Sciences, Institute of Virology, Dúbravská cesta 9, 845 05, Bratislava, Slovakia
| | - Kristína Boršová
- Biomedical Research Center, Slovak Academy of Sciences, Institute of Virology, Dúbravská cesta 9, 845 05, Bratislava, Slovakia
| | - Monika Sláviková
- Biomedical Research Center, Slovak Academy of Sciences, Institute of Virology, Dúbravská cesta 9, 845 05, Bratislava, Slovakia
| | - Veronika Vaňová
- Biomedical Research Center, Slovak Academy of Sciences, Institute of Virology, Dúbravská cesta 9, 845 05, Bratislava, Slovakia
- Department of Microbiology and Virology, Faculty of Natural Sciences, Comenius University, Ilkovičova 6, 842 15, Bratislava, Slovakia
| | - Boris Klempa
- Biomedical Research Center, Slovak Academy of Sciences, Institute of Virology, Dúbravská cesta 9, 845 05, Bratislava, Slovakia
- Department of Microbiology and Virology, Faculty of Natural Sciences, Comenius University, Ilkovičova 6, 842 15, Bratislava, Slovakia
| | - Pavol Čekan
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia.
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA.
| | - Evan D Paul
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia.
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA.
| |
Collapse
|
9
|
Huang X, Xiao F, Jia N, Sun C, Fu J, Xu Z, Cui X, Huang H, Qu D, Zhou J, Wang Y. Loop-mediated isothermal amplification combined with lateral flow biosensor for rapid and sensitive detection of monkeypox virus. Front Public Health 2023; 11:1132896. [PMID: 37033067 PMCID: PMC10080115 DOI: 10.3389/fpubh.2023.1132896] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 03/07/2023] [Indexed: 04/11/2023] Open
Abstract
The ongoing outbreak of the monkeypox, caused by monkeypox virus (MPXV), has been a public health emergency of international concern, indicating an urgent need for rapid and sensitive MPXV detection. Here, we designed a diagnostic test based on loop-mediated isothermal amplification (LAMP) and nanoparticle-based lateral flow biosensor(LFB)for diagnosis of MPXV infection, termed MPX-LAMP-LFB. A set of six LAMP primers was designed based the ATI gene of MPXV, and LAMP amplification of MPXV templates was performed at 63°C for only 40 min. The results were rapidly and visually decided using the LFB test within 2 min. The MPX-LAMP-LFB assay can specifically detect MPXV strains without cross-reaction with non-MPXV pathogens. The sensitivity of the MPX-LAMP-LFB assay is as low as 5 copies/μl of plasmid template and 12.5 copies/μl of pseudovirus in human blood samples. The whole process of the MPX-LAMP-LFB assay could be completed ~1 h, including rapid template preparation (15 min), LAMP reaction (40 min)and result reporting (<2 min). Collectively, MPX-LAMP-LFB assay developed here is a useful tool for rapid and reliable diagnosis of MPXV infection.
Collapse
Affiliation(s)
- Xiaolan Huang
- Experimental Research Center, Capital Institute of Pediatrics, Beijing, China
| | - Fei Xiao
- Experimental Research Center, Capital Institute of Pediatrics, Beijing, China
| | - Nan Jia
- Experimental Research Center, Capital Institute of Pediatrics, Beijing, China
| | - Chunrong Sun
- Experimental Research Center, Capital Institute of Pediatrics, Beijing, China
| | - Jin Fu
- Experimental Research Center, Capital Institute of Pediatrics, Beijing, China
| | - Zheng Xu
- Experimental Research Center, Capital Institute of Pediatrics, Beijing, China
| | - Xiaodai Cui
- Experimental Research Center, Capital Institute of Pediatrics, Beijing, China
| | - Hui Huang
- Department of Infectious Diseases, Children’s Hospital Affiliated Capital Institute of Pediatrics, Beijing, China
- *Correspondence: Hui Huang,
| | - Dong Qu
- Department of Critical Medicine, Children’s Hospital Affiliated Capital Institute of Pediatrics, Beijing, China
- Dong Qu,
| | - Juan Zhou
- Experimental Research Center, Capital Institute of Pediatrics, Beijing, China
- Juan Zhou,
| | - Yi Wang
- Experimental Research Center, Capital Institute of Pediatrics, Beijing, China
- Yi Wang,
| |
Collapse
|
10
|
Abstract
INTRODUCTION The SARS-CoV-2 pandemic, and the subsequent limitations on standard diagnostics, has vastly expanded the user base of Reverse Transcription Loop-mediated isothermal Amplification (RT-LAMP) in fundamental research and development. RT-LAMP has also penetrated commercial markets, with emergency use authorizations for clinical diagnosis. AREAS COVERED This review discusses the role of RT-LAMP within the context of other technologies like RT-qPCR and rapid antigen tests, progress in sample preparation strategies to enable simplified workflow for RT-LAMP directly from clinical specimens, new challenges with primer and assay design for the evolving pandemic, prominent detection modalities including colorimetric and CRISPR-mediated methods, and translational research and commercial development of RT-LAMP for clinical applications. EXPERT OPINION RT-LAMP occupies a middle ground between RT-qPCR and rapid antigen tests. The simplicity approaches that of rapid antigen tests, making it suitable for point-of-care use, but the sensitivity nears that of RT-qPCR. RT-LAMP still lags RT-qPCR in fundamental understanding of the mechanism, and the interplay between sample preparation and assay performance. Industry is now beginning to address issues around scalability and usability, which could finally enable LAMP and RT-LAMP to find future widespread application as a diagnostic for other conditions, including other pathogens with pandemic potential.
Collapse
Affiliation(s)
- Gihoon Choi
- Biotechnology & Bioengineering Department, Sandia National Laboratories, Livermore, CA, USA
| | - Taylor J Moehling
- Biotechnology & Bioengineering Department, Sandia National Laboratories, Livermore, CA, USA
| | - Robert J Meagher
- Biotechnology & Bioengineering Department, Sandia National Laboratories, Livermore, CA, USA
| |
Collapse
|
11
|
Oscorbin IP, Novikova LM, Filipenko ML. Comparison of Reverse Transcriptase (RT) Activities of Various M-MuLV RTs for RT-LAMP Assays. BIOLOGY 2022; 11:biology11121809. [PMID: 36552320 PMCID: PMC9775983 DOI: 10.3390/biology11121809] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/10/2022] [Accepted: 12/12/2022] [Indexed: 12/15/2022]
Abstract
Reverse transcriptases (RTs) are a family of enzymes synthesizing DNA using RNA as a template and serving as indispensable tools in studies related to RNA. M-MuLV RT and its analogs are the most commonly used RTs. RTs are widely applied in various diagnostics methods, including reverse-transcription loop-mediated isothermal amplification (RT-LAMP). However, the performance of different RTs in LAMP remains relatively unknown. Here, we report on the first direct comparison of various M-MuLV RTs in RT-LAMP, including enzymes with a different number of mutations and fusions with Sto7d. Several parameters were assessed, namely: optimal reaction temperature, enzyme concentration, reverse transcription time, a minimal amount of RNA template, and tolerance to inhibitors. Mutations increased the optimal reaction temperature from 55 °C to 60-65 °C. All of the RTs were suitable for RT-LAMP with RNA templates in the range of 101-106 copies per reaction. Highly mutated enzymes were 1.5-3-fold more tolerant to whole blood, blood plasma, and guanidinium, but they were two-fold more sensitive to high concentrations of NaCl. The comparison of different RTs presented here could be helpful for selecting the optimal enzyme when developing novel LAMP-based diagnostic tests.
Collapse
|
12
|
Development of an optimized colorimetric RT-LAMP for SARS-CoV-2 assay with enhanced procedure controls for remote diagnostics. Sci Rep 2022; 12:21424. [PMID: 36503901 PMCID: PMC9741705 DOI: 10.1038/s41598-022-25872-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 12/06/2022] [Indexed: 12/14/2022] Open
Abstract
The coronavirus pandemic accentuated the need for molecular diagnostic tests. A technique highly used to this end is the Polymerase Chain Reaction (PCR)-a sensitive and specific technique commonly used as the gold standard for molecular diagnostics. However, it demands highly trained personnel and high-maintenance equipment and is relatively time-consuming. An alternative is the Loop-Mediated Isothermal Amplification (LAMP) technique, which doesn't need sample purification or expensive equipment, and is similar to PCR when compared in sensitivity and specificity. In this paper, we developed an optimized colorimetric Reverse Transcriptase Loop-Mediated Isothermal Amplification (RT-LAMP) Point-of-Care test using a portable device to diagnose COVID-19. Variables such as concentration of primers, magnesium sulfate, betaine, hydrochloride guanidine, Bst, and temperature of the reactions were tested. We also created a pipetting quality control system-using a combination of dyes-to avoid false negatives due to a lack of samples added to the reaction test tube. Mineral oil was incorporated in the composition of the RT-LAMP reactions to avoid evaporation when a heating lid isn't available. The final RT-LAMP test is tenfold more sensitive when compared to the WarmStart Colorimetric Master mix from New England Biolabs with a sensitivity of 5 copies per μL.
Collapse
|
13
|
Tsang NNY, So HC, Cowling BJ, Leung GM, Ip DKM. Performance of saline and water gargling for SARS-CoV-2 reverse transcriptase PCR testing: a systematic review and meta-analysis. Eur Respir Rev 2022; 31:31/165/220014. [PMID: 36130785 DOI: 10.1183/16000617.0014-2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Accepted: 06/21/2022] [Indexed: 11/05/2022] Open
Abstract
The performance of gargling for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) reverse transcriptase (RT)-PCR testing has not been previously reviewed. This review systematically assessed the performance of saline and water gargling for SARS-CoV-2 RT-PCR testing in the settings of diagnosing and monitoring viral shedding.We included original studies comparing the performance of gargling and (oropharyngeal-)nasopharyngeal swabs for SARS-CoV-2 RT-PCR testing. Studies conducted in either suspected individuals or confirmed cases were included and analysed separately. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were examined using random-effects models.Gargles achieved a high overall sensitivity (91%), specificity (97%), PPV (95%) and NPV (91%) for SARS-CoV-2 RT-PCR testing. Studies using saline gargle and water gargle have an overall sensitivity of 97% and 86%, respectively. The sensitivity values were largely maintained for saline and water gargling on stratified analysis, for both diagnosis (96% and 92%) and viral shedding monitoring (98% and 78%). A higher sensitivity was also reported by studies using sterile saline (100%), a smaller amount of gargling solution (92% versus 87%) and a longer gargling duration (95% versus 86%).Our results supported the use of gargling as a sampling approach for SARS-CoV-2 RT-PCR testing, which achieved a high sensitivity for both diagnosis and viral shedding monitoring purposes. Further investigation on the comparative performance of different gargling mediums is needed to draw a definitive conclusion.
Collapse
Affiliation(s)
- Nicole Ngai Yung Tsang
- WHO Collaborating Centre for Infectious Disease Epidemiology and Control, School of Public Health, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Hau Chi So
- WHO Collaborating Centre for Infectious Disease Epidemiology and Control, School of Public Health, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Benjamin J Cowling
- WHO Collaborating Centre for Infectious Disease Epidemiology and Control, School of Public Health, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Gabriel M Leung
- WHO Collaborating Centre for Infectious Disease Epidemiology and Control, School of Public Health, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Dennis Kai Ming Ip
- WHO Collaborating Centre for Infectious Disease Epidemiology and Control, School of Public Health, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region, China
| |
Collapse
|
14
|
Kosnik IG, Dermota U, Golle A, Cretnik TZ. Rapid antigen test for SARS-CoV-2: results of validation and use in real life. Future Virol 2022. [PMID: 36186521 PMCID: PMC9514382 DOI: 10.2217/fvl-2022-0045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Accepted: 09/12/2022] [Indexed: 11/24/2022]
Abstract
Aim: To verify a SARS-CoV-2 rapid antigen test (RAT) compared with PCR. Materials & methods: Validation of RAT included 2295 subjects. Next matching of RAT with the PCR was checked in 13,852 subjects referred to PCR after being positive in RAT. Results: Sensitivity and specificity of RAT were 77.38 and 99.10%, respectively. A 74.60% of RAT positive results were confirmed with PCR. Conclusion: The test met WHO susceptibility criteria in a group of symptomatic subjects. In terms of specificity, it met requirements in all subjects. The concordance of RAT with PCR in real life was in line with our verification data.
Collapse
Affiliation(s)
- Irena Grmek Kosnik
- National Laboratory for Health, Environment & Food, Prvomajska 2, 2000, Maribor, Slovenia
| | - Urska Dermota
- National Laboratory for Health, Environment & Food, Prvomajska 2, 2000, Maribor, Slovenia
| | - Andrej Golle
- National Laboratory for Health, Environment & Food, Prvomajska 2, 2000, Maribor, Slovenia
| | - Tjasa Zohar Cretnik
- National Laboratory for Health, Environment & Food, Prvomajska 2, 2000, Maribor, Slovenia
| |
Collapse
|
15
|
Delgado-Diaz DJ, Sakthivel D, Nguyen HHT, Farrokzhad K, Hopper W, Narh CA, Richards JS. Strategies That Facilitate Extraction-Free SARS-CoV-2 Nucleic Acid Amplification Tests. Viruses 2022; 14:v14061311. [PMID: 35746782 PMCID: PMC9230587 DOI: 10.3390/v14061311] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Revised: 06/12/2022] [Accepted: 06/13/2022] [Indexed: 02/01/2023] Open
Abstract
The COVID-19 pandemic has resulted in an unprecedented global demand for in vitro diagnostic reagents. Supply shortages and hoarding have impacted testing capacity which has led to inefficient COVID-19 case identification and transmission control, predominantly in developing countries. Traditionally, RNA extraction is a prerequisite for conducting SARS-CoV-2 nucleic acid amplification tests (NAAT); however, simplified methods of sample processing have been successful at bypassing typical nucleic acid extraction steps, enabling extraction-free SARS-CoV-2 NAAT workflows. These methods involve chemical and physical approaches that are inexpensive and easily accessible alternatives to overcome extraction kit supply shortages, while offering acceptable test performance. Here we provide an overview of three main sample preparation strategies that have been shown to facilitate extraction-free SARS-CoV-2 NAATs.
Collapse
Affiliation(s)
- David J. Delgado-Diaz
- ZIP Diagnostics Pty Ltd., Collingwood, VIC 3066, Australia; (D.S.); (H.H.T.N.); (K.F.); (W.H.); (C.A.N.); (J.S.R.)
- Correspondence:
| | - Dhanasekaran Sakthivel
- ZIP Diagnostics Pty Ltd., Collingwood, VIC 3066, Australia; (D.S.); (H.H.T.N.); (K.F.); (W.H.); (C.A.N.); (J.S.R.)
| | - Hanh H. T. Nguyen
- ZIP Diagnostics Pty Ltd., Collingwood, VIC 3066, Australia; (D.S.); (H.H.T.N.); (K.F.); (W.H.); (C.A.N.); (J.S.R.)
| | - Khashayar Farrokzhad
- ZIP Diagnostics Pty Ltd., Collingwood, VIC 3066, Australia; (D.S.); (H.H.T.N.); (K.F.); (W.H.); (C.A.N.); (J.S.R.)
| | - William Hopper
- ZIP Diagnostics Pty Ltd., Collingwood, VIC 3066, Australia; (D.S.); (H.H.T.N.); (K.F.); (W.H.); (C.A.N.); (J.S.R.)
| | - Charles A. Narh
- ZIP Diagnostics Pty Ltd., Collingwood, VIC 3066, Australia; (D.S.); (H.H.T.N.); (K.F.); (W.H.); (C.A.N.); (J.S.R.)
- Department of Medicine, University of Melbourne, Melbourne, VIC 3010, Australia
- Department of Infectious Diseases, Monash University, Melbourne, VIC 3004, Australia
| | - Jack S. Richards
- ZIP Diagnostics Pty Ltd., Collingwood, VIC 3066, Australia; (D.S.); (H.H.T.N.); (K.F.); (W.H.); (C.A.N.); (J.S.R.)
- Department of Medicine, University of Melbourne, Melbourne, VIC 3010, Australia
- Department of Infectious Diseases, Monash University, Melbourne, VIC 3004, Australia
| |
Collapse
|
16
|
Dignan LM, Turiello R, Layne TR, O'Connell KC, Hickey J, Chapman J, Poulter MD, Landers JP. An ultrafast SARS-CoV-2 virus enrichment and extraction method compatible with multiple modalities for RNA detection. Anal Chim Acta 2021; 1180:338846. [PMID: 34538333 PMCID: PMC8277111 DOI: 10.1016/j.aca.2021.338846] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 06/10/2021] [Accepted: 07/06/2021] [Indexed: 01/08/2023]
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a zoonotic RNA virus characterized by high transmission rates and pathogenicity worldwide. Continued control of the COVID-19 pandemic requires the diversification of rapid, easy to use, sensitive, and portable methods for SARS-CoV-2 sample preparation and analysis. Here, we propose a method for SARS-CoV-2 viral enrichment and enzymatic extraction of RNA from clinically relevant matrices in under 10 min. This technique utilizes affinity-capture hydrogel particles to concentrate SARS-CoV-2 from solution, and leverages existing PDQeX technology for RNA isolation. Characterization of our method is accomplished with reverse transcription real-time polymerase chain reaction (RT-PCR) for relative, comparative RNA detection. In a double-blind study analyzing viral transport media (VTM) obtained from clinical nasopharyngeal swabs, our sample preparation method demonstrated both comparable results to a routinely used commercial extraction kit and 100% concordance with laboratory diagnoses. Compatibility of eluates with alternative forms of analysis was confirmed using microfluidic RT-PCR (μRT-PCR), recombinase polymerase amplification (RPA), and loop-mediated isothermal amplification (LAMP). The alternative methods explored here conveyed successful amplification from all RNA eluates originating from positive clinical samples. Finally, this method demonstrated high performance within a saliva matrix across a broad range of viral titers and dilutions up to 90% saliva matrix, and sets the stage for miniaturization to the microscale.
Collapse
Affiliation(s)
- Leah M. Dignan
- Departments of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
| | - Rachelle Turiello
- Departments of Chemistry, University of Virginia, Charlottesville, VA 22904, USA,Corresponding author
| | - Tiffany R. Layne
- Departments of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
| | - Killian C. O'Connell
- Departments of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
| | - Jeff Hickey
- MicroGEM International PLC., Charlottesville, VA 22904, USA
| | - Jeff Chapman
- MicroGEM International PLC., Charlottesville, VA 22904, USA
| | - Melinda D. Poulter
- Departments of Pathology, University of Virginia, Charlottesville, VA 22904, USA
| | - James P. Landers
- Departments of Chemistry, University of Virginia, Charlottesville, VA 22904, USA,MicroGEM International PLC., Charlottesville, VA 22904, USA,Departments of Pathology, University of Virginia, Charlottesville, VA 22904, USA,Departments of Clinical Microbiology, University of Virginia, Charlottesville, VA 22904, USA,Departments of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA 22904, USA
| |
Collapse
|
17
|
Matute T, Nuñez I, Rivera M, Reyes J, Blázquez-Sánchez P, Arce A, Brown AJ, Gandini C, Molloy J, Ramírez-Sarmiento CA, Federici F. Homebrew reagents for low-cost RT-LAMP. J Biomol Tech 2021; 32:114-120. [PMID: 35027869 PMCID: PMC8730520 DOI: 10.7171/jbt.21-3203-006] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/18/2023]
Abstract
Reverse transcription-loop-mediated isothermal amplification (RT-LAMP) has gained popularity for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The high specificity, sensitivity, simple protocols, and potential to deliver results without the use of expensive equipment has made it an attractive alternative to RT-PCR. However, the high cost per reaction, the centralized manufacturing of required reagents, and their distribution under cold chain shipping limit RT-LAMP's applicability in low-income settings. The preparation of assays using homebrew enzymes and buffers has emerged worldwide as a response to these limitations and potential shortages. Here, we describe the production of Moloney murine leukemia virus reverse transcriptase and BstLF DNA polymerase for the local implementation of RT-LAMP reactions at low cost. These reagents compared favorably to commercial kits, and optimum concentrations were defined in order to reduce time to threshold, increase ON/OFF range, and minimize enzyme quantities per reaction. As a validation, we tested the performance of these reagents in the detection of SARS-CoV-2 from RNA extracted from clinical nasopharyngeal samples, obtaining high agreement between RT-LAMP and RT-PCR clinical results. The in-house preparation of these reactions results in an order of magnitude reduction in costs; thus, we provide protocols and DNA to enable the replication of these tests at other locations. These results contribute to the global effort of developing open and low-cost diagnostics that enable technological autonomy and distributed capacities in viral surveillance.
Collapse
Affiliation(s)
- Tamara Matute
- ANID – Millennium Science Initiative Program – Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Isaac Nuñez
- ANID – Millennium Science Initiative Program – Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Maira Rivera
- ANID – Millennium Science Initiative Program – Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Javiera Reyes
- ANID – Millennium Science Initiative Program – Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Paula Blázquez-Sánchez
- ANID – Millennium Science Initiative Program – Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Aníbal Arce
- ANID – Millennium Science Initiative Program – Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Alexander J. Brown
- Department of Immunology and Genomic Medicine, National Jewish Health, Denver, Colorado, USA
- Department of Immunology & Microbiology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Chiara Gandini
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, United Kingdom
| | - Jennifer Molloy
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, United Kingdom
| | - César A. Ramírez-Sarmiento
- ANID – Millennium Science Initiative Program – Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Fernán Federici
- ANID – Millennium Science Initiative Program – Millennium Institute for Integrative Biology (iBio), Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
- FONDAP Center for Genome Regulation, Departamento de Genética Molecular y Microbiología, Pontificia Universidad Católica de Chile, Santiago 8331150, Chile
| |
Collapse
|