1
|
Ahmad MI, Amorim CG, Abu Qatouseh LF, Montenegro MCBSM. Nanobody-based immunosensor for the detection of H. pylori in saliva. Biosens Bioelectron 2024; 260:116423. [PMID: 38810413 DOI: 10.1016/j.bios.2024.116423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 05/20/2024] [Accepted: 05/22/2024] [Indexed: 05/31/2024]
Abstract
Helicobacter pylori (H. pylori) infection is highly prevalent worldwide, affecting more than 43% of world population. The infection can be transmitted through different routes, like oral-oral, fecal-oral, and gastric-oral. Electrochemical sensors play a crucial role in the early detection of various substances, including biomolecules. In this study, the development of nanobody (Nb)-based immunosensor for the detection of H. pylori antigens in saliva samples was investigated. The D2_Nb was isolated and characterized using Western blot and ELISA and employed in the fabrication of the immunosensor. The sensor was prepared using gold screen-printed electrodes, with the immobilization of Nb achieved through chemical linkage using cysteamine-glutaraldehyde. The surface of the electrode was characterized using EIS, FTIR and SEM. Initially, the Nb-based immunosensor's performance was evaluated through cyclic voltammetry (CV), differential pulse voltammetry (DPV), and square wave voltammetry (SWV). The sensor exhibited excellent linearity with an R2 value of 0.96. However, further assessment with the DPV technique revealed both a low limit of detection (5.9 ng/mL, <1 cfu/mL) and high selectivity when exposed to a mixture of similar antigens. Moreover, the immunosensor demonstrated robust recovery rates (96.2%-103.4%) when spiked into artificial saliva and maintained its functionality when stored at room temperature for 24 days.
Collapse
Affiliation(s)
- Mohammad Ia Ahmad
- LAQV-REQUIMTE, Department of Chemical Sciences, Faculty of Pharmacy, University of Porto, Porto, Portugal
| | - Célia G Amorim
- LAQV-REQUIMTE, Department of Chemical Sciences, Faculty of Pharmacy, University of Porto, Porto, Portugal.
| | - Luay F Abu Qatouseh
- Department of Pharmacology and Biomedical Sciences, Faculty of Pharmacy and Medical Sciences, University of Petra, Amman, Jordan.
| | - Maria C B S M Montenegro
- LAQV-REQUIMTE, Department of Chemical Sciences, Faculty of Pharmacy, University of Porto, Porto, Portugal
| |
Collapse
|
2
|
Jaradat H, Hryniewicz BM, Pašti IA, Valério TL, Al-Hamry A, Marchesi LF, Vidotti M, Kanoun O. Detection of H. pylori outer membrane protein (HopQ) biomarker using electrochemical impedimetric immunosensor with polypyrrole nanotubes and carbon nanotubes nanocomposite on screen-printed carbon electrode. Biosens Bioelectron 2024; 249:115937. [PMID: 38211465 DOI: 10.1016/j.bios.2023.115937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 12/15/2023] [Accepted: 12/16/2023] [Indexed: 01/13/2024]
Abstract
Helicobacter pylori (H. pylori) is classified as a class I carcinogen that colonizes the human gastrointestinal (GI) tract. The detection at low concentrations is crucial in combatting H. pylori. HopQ protein is located on H. pylori's outer membrane and is expressed at an early stage of contamination, which signifies it as an ideal biomarker. In this study, we presented the development of an electrochemical impedimetric immunosensor for the ultra-sensitive detection of HopQ at low concentrations. The sensor employed polypyrrole nanotubes (PPy-NTs) and carboxylated multi-walled carbon nanotubes (MWCNT-COOH) nanocomposite. PPy-NTs were chosen for their excellent conductivity, biocompatibility, and redox capabilities, simplifying sample preparation by eliminating the need to add redox probes upon measurement. MWCNT-COOH provided covalent binding sites for HopQ antibodies (HopQ-Ab) on the biosensor surface. Characterization of the biosensor was performed using scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), contact angle measurements, and electrochemical impedance spectroscopy (EIS), complemented by numerical semiempirical quantum calculations. The results demonstrated a dynamic linear range of 5 pg/mL to 1.063 ng/mL and an excellent selectivity, with the possibility of excluding interference using EIS data, specifically charge transfer resistance and double-layer capacitance as multivariants for the calibration curve. Using two EIS components, the limit of detection is calculated to be 2.06 pg/mL. The biosensor was tested with a spiked drinking water sample and showed a signal recovery of 105.5% when detecting 300 pg/mL of HopQ. This novel H. pylori biosensor offers reliable, simple, portable, and rapid screening of the bacteria.
Collapse
Affiliation(s)
- Hussamaldeen Jaradat
- Professorship of Measurement and Sensor Technology, Faculty of Electrical Engineering and Information Technology, Chemnitz University of Technology, 09126, Chemnitz, Germany.
| | - Bruna M Hryniewicz
- Grupo de Pesquisa em Macromoléculas e Interfaces, Departamento de Química, Universidade Federal do Paraná (UFPR), Curitiba, 81531-980, PR, Brazil.
| | - Igor A Pašti
- University of Belgrade-Faculty of Physical Chemistry, Studentski trg 12-16, 11158, Belgrade, Serbia.
| | - Tatiana L Valério
- Grupo de Pesquisa em Macromoléculas e Interfaces, Departamento de Química, Universidade Federal do Paraná (UFPR), Curitiba, 81531-980, PR, Brazil.
| | - Ammar Al-Hamry
- Professorship of Measurement and Sensor Technology, Faculty of Electrical Engineering and Information Technology, Chemnitz University of Technology, 09126, Chemnitz, Germany.
| | - Luís F Marchesi
- Grupo de Estudos em Espectroscopia de Impedância Eletroquímica (GEIS), Universidade Tecnológica Federal Do Paraná, Rua Dr. Washington Subtil Chueire, 330 - Jd. Carvalho, CEP 84017-220, Ponta Grossa, PR, Brazil.
| | - Marcio Vidotti
- Grupo de Pesquisa em Macromoléculas e Interfaces, Departamento de Química, Universidade Federal do Paraná (UFPR), Curitiba, 81531-980, PR, Brazil.
| | - Olfa Kanoun
- Professorship of Measurement and Sensor Technology, Faculty of Electrical Engineering and Information Technology, Chemnitz University of Technology, 09126, Chemnitz, Germany.
| |
Collapse
|