Michel P, Boudenne JL, Coulomb B, Robert-Peillard F. Spectrofluorimetric determination of acetone in water samples with solid-phase extraction and a new benzaldehyde derivative. Talanta 2024; 282:126984. [PMID: 39368330 DOI: 10.1016/j.talanta.2024.126984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2024] [Revised: 09/20/2024] [Accepted: 10/02/2024] [Indexed: 10/07/2024]
Abstract
A new method is described for acetone (C(CH3)2O) determination in water samples. The method is based on the reaction with 4-(dimethylamino)benzaldehyde (DMAB) in dimethyl sulfoxide (DMSO) in slightly basic medium, resulting in a highly fluorescent compound with fluorescent wavelengths undisturbed by other common fluorescent compounds. Experimental conditions were optimized (reagents concentrations, reaction time) to reach optimal sensitivity. For the analysis of aqueous samples, a preconcentration step of acetone by solid-phase extraction (SPE) followed by an elution step in DMSO was optimized using Isolute ENV + columns. A highly satisfactory low detection limit of 0.014 μM (0.8 μg L-1) was achieved by combining these two steps, with a linear range from 0.048 to 5 μM and relative standard deviations between 5.7 % and 6.9 %. The protocol was validated on complex real water samples such as river water and wastewater, and our fluorimetric method with DMAB was in good agreement with the reference LC-UV method with DNPH.
Collapse
Affiliation(s)
- P Michel
- Aix Marseille Univ, LCE, Marseille, France
| | | | - B Coulomb
- Aix Marseille Univ, LCE, Marseille, France
| | | |
Collapse
|
2
|
Chaudhary V, Taha BA, Lucky, Rustagi S, Khosla A, Papakonstantinou P, Bhalla N. Nose-on-Chip Nanobiosensors for Early Detection of Lung Cancer Breath Biomarkers. ACS Sens 2024; 9:4469-4494. [PMID: 39248694 PMCID: PMC11443536 DOI: 10.1021/acssensors.4c01524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/10/2024]
Abstract
Lung cancer remains a global health concern, demanding the development of noninvasive, prompt, selective, and point-of-care diagnostic tools. Correspondingly, breath analysis using nanobiosensors has emerged as a promising noninvasive nose-on-chip technique for the early detection of lung cancer through monitoring diversified biomarkers such as volatile organic compounds/gases in exhaled breath. This comprehensive review summarizes the state-of-the-art breath-based lung cancer diagnosis employing chemiresistive-module nanobiosensors supported by theoretical findings. It unveils the fundamental mechanisms and biological basis of breath biomarker generation associated with lung cancer, technological advancements, and clinical implementation of nanobiosensor-based breath analysis. It explores the merits, challenges, and potential alternate solutions in implementing these nanobiosensors in clinical settings, including standardization, biocompatibility/toxicity analysis, green and sustainable technologies, life-cycle assessment, and scheming regulatory modalities. It highlights nanobiosensors' role in facilitating precise, real-time, and on-site detection of lung cancer through breath analysis, leading to improved patient outcomes, enhanced clinical management, and remote personalized monitoring. Additionally, integrating these biosensors with artificial intelligence, machine learning, Internet-of-things, bioinformatics, and omics technologies is discussed, providing insights into the prospects of intelligent nose-on-chip lung cancer sniffing nanobiosensors. Overall, this review consolidates knowledge on breathomic biosensor-based lung cancer screening, shedding light on its significance and potential applications in advancing state-of-the-art medical diagnostics to reduce the burden on hospitals and save human lives.
Collapse
Affiliation(s)
- Vishal Chaudhary
- Physics Department, Bhagini Nivedita College, University of Delhi, 110043 Delhi, India
- Centre for Research Impact & Outcome, Chitkara University, Punjab 140401, India
| | - Bakr Ahmed Taha
- Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, UKM, 43600 Bangi, Malaysia
| | - Lucky
- Dr. B. R. Ambedkar Center for Biomedical Research, University of Delhi, 110007 Delhi, India
| | - Sarvesh Rustagi
- School of Applied and Life Sciences, Uttaranchal University, Dehradun, Uttarakhand 248007, India
| | - Ajit Khosla
- School of Advanced Materials and Nanotechnology, Xidian University, Xi'an 710126, China
| | - Pagona Papakonstantinou
- Nanotechnology and Integrated Bioengineering Centre (NIBEC), School of Engineering, Ulster University, 2-24 York Street, Belfast, Northern Ireland BT15 1AP, United Kingdom
| | - Nikhil Bhalla
- Nanotechnology and Integrated Bioengineering Centre (NIBEC), School of Engineering, Ulster University, 2-24 York Street, Belfast, Northern Ireland BT15 1AP, United Kingdom
- Healthcare Technology Hub, Ulster University, 2-24 York Street, Belfast, Northern Ireland BT15 1AP, United Kingdom
| |
Collapse
|
3
|
Gashimova E, Temerdashev A, Perunov D, Porkhanov V, Polyakov I. Diagnosis of Lung Cancer Through Exhaled Breath: A Comprehensive Study. Mol Diagn Ther 2024:10.1007/s40291-024-00744-8. [PMID: 39299985 DOI: 10.1007/s40291-024-00744-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/03/2024] [Indexed: 09/22/2024]
Abstract
OBJECTIVES Exhaled breath analysis is an attractive lung cancer diagnostic tool. However, various factors that are not related to the disease status, comorbidities, and other diseases must be considered to obtain a reliable diagnostic model. METHODS Exhaled breath samples from 646 individuals including 273 patients with lung cancer (LC), 90 patients with cancer of other localizations (OC), 150 patients with noncancer lung diseases (NLD), and 133 healthy controls (HC) were analyzed using gas chromatography-mass spectrometry (GC-MS). The samples were collected in Tedlar bags. Volatile organic compounds (VOCs) were preconcentrated on Tenax TA sorbent tubes with subsequent two-stage thermal desorption followed by GC-MS analysis. The influence of age, gender, smoking status, time since last food consumption, and comorbidities on exhaled breath were evaluated. Also, the effect of histology, TNM, tumor localization, treatment status, and the presence of a tumor on VOC profile of patients with lung cancer were assessed. Intergroup statistics were estimated, diagnostic models were created using artificial neural networks (ANNs) and gradient boosted decision trees (GBDTs). RESULTS Smoking status and food consumption affect exhaled breath VOC profile: benzene, ethylbenzene, toluene, 1,3-pentadiene 1,4-pentadiene acetonitrile, and some ratios are significantly different in exhaled breath of smokers and nonsmokers; the ratios 2,3-butandione/2-pentanone, 2,3-butandione/dimethylsulfide, and 2-butanone/2-pentanone are affected by time since last food consumption. Exhaled breath of LC is affected by the form of the disease and comorbidities. One-pentanol and 2-butanone were different in exhaled breath of patients with various tumor localization; 2-butanone was different in exhaled breath of patients before and during treatment. Diabetes as a comorbidity affects the pentanal level in exhaled breath; obesity affects the ratios of 2,3-butanedione/dimethylsulfide and 2-butanone/isoprene. Sensitivity and specificity of diagnostic models aimed to discriminate LC and HC, OC, and NLD were 78.7% and 51.0%, 62.2% and 53.4%, and 60.4% and 58.0%, respectively. HC and patients, regardless of the disease, can be classified with sensitivity of 76.6% and specificity of 68.2%. CONCLUSIONS The models created to diagnose lung cancer can also classify OC and NLD as patients with lung cancer. Additionally, the influence of comorbidities and factors not related to the disease status must be considered before the creation of diagnostic models to avoid false results.
Collapse
Affiliation(s)
- Elina Gashimova
- Kuban State University, Stavropol'skaya St. 149, Krasnodar, 350040, Russia.
| | - Azamat Temerdashev
- Kuban State University, Stavropol'skaya St. 149, Krasnodar, 350040, Russia
| | - Dmitry Perunov
- Research Institute, Regional Clinical Hospital, No 1 n.a. Prof. S.V. Ochapovsky, 1 May St. 167, Krasnodar, 350086, Russia
| | - Vladimir Porkhanov
- Research Institute, Regional Clinical Hospital, No 1 n.a. Prof. S.V. Ochapovsky, 1 May St. 167, Krasnodar, 350086, Russia
| | - Igor Polyakov
- Research Institute, Regional Clinical Hospital, No 1 n.a. Prof. S.V. Ochapovsky, 1 May St. 167, Krasnodar, 350086, Russia
| |
Collapse
|
4
|
Suchorska-Woźniak P, Teterycz H. ZnO Hexagonal Nano- and Microplates Modified with Nanomaterials as a Gas-Sensitive Material for DMS Detection-Extended Studies. SENSORS (BASEL, SWITZERLAND) 2024; 24:5690. [PMID: 39275601 PMCID: PMC11398269 DOI: 10.3390/s24175690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2024] [Revised: 08/20/2024] [Accepted: 08/27/2024] [Indexed: 09/16/2024]
Abstract
The detection of dimethyl sulphide (DMS) at levels between ppb and ppm is a significant area of research due to the necessity of monitoring the presence of this gas in a variety of environments. These include environmental protection, industrial safety and medical diagnostics. Issues related to certain uncertainties concerning the influence of high humidity on DMS measurements with resistive gas sensors, e.g., in the detection of this marker in exhaled air, of the still unsatisfactory lower detection limit of DMS are the subject of intensive research. This paper presents the results of modifying the composition of the ZnO-based sensor layer to develop a DMS sensor with higher sensitivity and lower detection limit (LOD). Improved performance was achieved by using ZnO in the form of hexagonal nano- and microplates doped with gold nanoparticles (0.75 wt.%) and by using a well-proven sepiolite-based passive filter. The modification of the layer composition with respect to the authors' previous studies contributed to the development of a sensor that is highly sensitive to 1 ppm DMS (S = 11.4) and achieves an LOD of up to 406 ppb, despite the presence of a high water vapour content (90% RH) in the analysed atmosphere.
Collapse
Affiliation(s)
- Patrycja Suchorska-Woźniak
- Faculty of Electronics, Photonics and Microsystems, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
| | - Helena Teterycz
- Faculty of Electronics, Photonics and Microsystems, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
| |
Collapse
|
5
|
Mirzaei A, Kim JY, Kim HW, Kim SS. Resistive Gas Sensors Based on 2D TMDs and MXenes. Acc Chem Res 2024; 57:2395-2413. [PMID: 39101684 DOI: 10.1021/acs.accounts.4c00323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/06/2024]
Abstract
ConspectusGas sensors are used in various applications to sense toxic gases, mainly for enhanced safety. Resistive sensors are particularly popular owing to their ability to detect trace amounts of gases, high stability, fast response times, and affordability. Semiconducting metal oxides are commonly employed in the fabrication of resistive gas sensors. However, these sensors often require high working temperatures, bringing about increased energy consumption and reduced selectivity. Furthermore, they do not have enough flexibility, and their performance is significantly decreased under bending, stretching, or twisting. To address these challenges, alternative materials capable of operating at lower temperatures with high flexibility are needed. Two-dimensional (2D) materials such as MXenes and transition-metal dichalcogenides (TMDs) offer high surface area and conductivity owing to their unique 2D structure, making them promising candidates for realization of resistive gas sensors. Nevertheless, their sensing performance in pristine form is typically weak and unacceptable, particularly in terms of response, selectivity, and recovery time (trec). To overcome these drawbacks, several strategies can be employed to enhance their sensing properties. Noble-metal decoration such as (Au, Pt, Pd, Rh, Ag) is a highly promising method, in which the catalytic effects of noble metals as well as formation of potential barriers with MXenes or TMDs eventually contribute to boosted response. Additionally, bimetallic noble metals such as Pt-Pd and Au/Pd with their synergistic properties can further improve sensor performance. Ion implantation is another feasible approach, involving doping of sensing materials with the desired concentration of dopants through control over the energy and dosage of the irradiation ions as well as creation of structural defects such as oxygen vacancies through high-energy ion-beam irradiation, contributing to enhanced sensing capabilities. The formation of core-shell structures is also effective, creating numerous interfaces between core and shell materials that optimize the sensing characteristics. However, the shell thickness needs to be carefully optimized to achieve the best sensing output. To reduce energy consumption, sensors can operate in a self-heating condition where an external voltage is applied to the electrodes, significantly lowering the power requirements. This enables sensors to function in energy-constrained environments, such as remote or low-energy areas. An important advantage of 2D MXenes and TMDs is their high mechanical flexibility. Unlike semiconducting metal oxides that lack mechanical flexibility, MXenes and TMDs can maintain their sensing performance even when integrated onto flexible substrates and subjected to bending, tilting, or stretching. This flexibility makes them ideal for fabricating flexible and portable gas sensors that rigid sensors cannot achieve.
Collapse
Affiliation(s)
- Ali Mirzaei
- Department of Materials Science and Engineering, Shiraz University of Technology, Shiraz 715557-13876, Islamic Republic of Iran
| | - Jin-Young Kim
- Department of Materials Science and Engineering, Inha University, Incheon 22212, Republic of Korea
| | - Hyoun Woo Kim
- Division of Materials Science and Engineering, Hanyang University, Seoul 04763, Republic of Korea
| | - Sang Sub Kim
- Department of Materials Science and Engineering, Inha University, Incheon 22212, Republic of Korea
| |
Collapse
|
6
|
Mohammadzadeh MR, Hasani A, Hussain T, Ghanbari H, Fawzy M, Abnavi A, Ahmadi R, Kabir F, De Silva T, Rajapakse RKND, Adachi MM. Enhanced Sensitivity in Photovoltaic 2D MoS 2/Te Heterojunction VOC Sensors. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024:e2402464. [PMID: 39058241 DOI: 10.1002/smll.202402464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 07/08/2024] [Indexed: 07/28/2024]
Abstract
Volatile organic compound (VOC) sensors have a broad range of applications including healthcare monitoring, product quality control, and air quality management. However, many such applications are demanding, requiring sensors with high sensitivity and selectivity. 2D materials are extensively used in many VOC sensing devices due to their large surface-to-volume ratio and fascinating electronic properties. These properties, along with their exceptional flexibility, low power consumption, room-temperature operation, chemical functionalization potential, and defect engineering capabilities, make 2D materials ideal for high-performance VOC sensing. Here, a 2D MoS2/Te heterojunction is reported that significantly improves the VOC detection compared to MoS2 and Te sensors on their own. Density functional theory (DFT) analysis shows that the MoS2/Te heterojunction significantly enhances the adsorption energy and therefore sensing sensitivity of the sensor. The sensor response, which denotes the percentage change in the sensor's conductance upon VOC exposure, is further enhanced under photo-illumination and zero-bias conditions to values up to ≈7000% when exposed to butanone. The MoS2/Te heterojunction is therefore a promising device architecture for portable and wearable sensing applications.
Collapse
Affiliation(s)
| | - Amirhossein Hasani
- School of Engineering Science, Simon Fraser University, Burnaby, British Columbia, V5A 1S6, Canada
- Department of Physics and MonArk NSF Quantum Foundry, Montana State University, Bozeman, MT, 59717, USA
| | - Tanveer Hussain
- School of Science and Technology, University of New England, Armidale, New South Wales, 2351, Australia
| | - Hamidreza Ghanbari
- School of Engineering Science, Simon Fraser University, Burnaby, British Columbia, V5A 1S6, Canada
| | - Mirette Fawzy
- Department of Physics, Simon Fraser University, Burnaby, British Columbia, V5A 1S6, Canada
| | - Amin Abnavi
- School of Engineering Science, Simon Fraser University, Burnaby, British Columbia, V5A 1S6, Canada
| | - Ribwar Ahmadi
- School of Engineering Science, Simon Fraser University, Burnaby, British Columbia, V5A 1S6, Canada
| | - Fahmid Kabir
- School of Engineering Science, Simon Fraser University, Burnaby, British Columbia, V5A 1S6, Canada
| | - Thushani De Silva
- School of Engineering Science, Simon Fraser University, Burnaby, British Columbia, V5A 1S6, Canada
| | - R K N D Rajapakse
- School of Engineering Science, Simon Fraser University, Burnaby, British Columbia, V5A 1S6, Canada
- Faculty of Engineering, Sri Lanka Institute of Information Technology, New Kandy Road, Malabe, 10115, Sri Lanka
| | - Michael M Adachi
- School of Engineering Science, Simon Fraser University, Burnaby, British Columbia, V5A 1S6, Canada
| |
Collapse
|
7
|
Yoshinaga K, Imasaka T, Imasaka T. Femtosecond Laser Ionization Mass Spectrometry for Online Analysis of Human Exhaled Breath. Anal Chem 2024; 96:11542-11548. [PMID: 38972070 DOI: 10.1021/acs.analchem.4c02214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/09/2024]
Abstract
A variety of organic compounds in human exhaled breath were measured online by mass spectrometry using the fifth (206 nm) and fourth (257 nm) harmonic emissions of a femtosecond ytterbium (Yb) laser as the ionization source. Molecular ions were enhanced significantly by means of resonance-enhanced, two-color, two-photon ionization, which was useful for discrimination of analytes against the background. The limit of detection was 0.15 ppm for acetone in air. The concentration of acetone in exhaled breath was determined for three subjects to average 0.31 ppm, which lies within the range of normal healthy subjects and is appreciably lower than the range for patients with diabetes mellitus. Many other constituents, which could be assigned to acetaldehyde, ethanol, isoprene, phenol, octane, ethyl butanoate, indole, octanol, etc., were observed in the exhaled air. Therefore, the present approach shows potential for use in the online analysis of diabetes mellitus and also for the diagnosis of various diseases, such as COVID-19 and cancers.
Collapse
Affiliation(s)
- Katsunori Yoshinaga
- Faculty of Design, Kyushu University, 4-9-1, Shiobaru, Minami-ku, Fukuoka 815-8540:744 Motooka, Nishi-ku Fukuoka 819-0395, Japan
| | - Totaro Imasaka
- Kyushu University, 744 Motooka, Nishi-ku Fukuoka 819-0395, Japan
- Hikari Giken, Co., 2-10-30, Sakurazaka, Chuou-ku Fukuoka 810-0024, Japan
| | - Tomoko Imasaka
- Faculty of Design, Kyushu University, 4-9-1, Shiobaru, Minami-ku, Fukuoka 815-8540:744 Motooka, Nishi-ku Fukuoka 819-0395, Japan
| |
Collapse
|
8
|
Yan T, Weng F, Ming Y, Zhu S, Zhu M, Wang C, Guo C, Zhu K. Luminescence Probes in Bio-Applications: From Principle to Practice. BIOSENSORS 2024; 14:333. [PMID: 39056609 PMCID: PMC11274413 DOI: 10.3390/bios14070333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2024] [Revised: 07/03/2024] [Accepted: 07/04/2024] [Indexed: 07/28/2024]
Abstract
Bioanalysis based on optical imaging has gained significant progress in the last few decades. Luminescence probes are capable of detecting, monitoring, and tracing particular biomolecules in complex biological systems to figure out the roles of these molecules in organisms. Considering the rapid development of luminescence probes for bio-applications and their promising future, we have attempted to explore the working principles and recent advances in bio-applications of luminescence probes, in the hope of helping readers gain a detailed understanding of luminescence probes developed in recent years. In this review, we first focus on the current widely used luminescence probes, including fluorescence probes, bioluminescence probes, chemiluminescence probes, afterglow probes, photoacoustic probes, and Cerenkov luminescence probes. The working principles for each type of luminescence probe are concisely described and the bio-application of the luminescence probes is summarized by category, including metal ions detection, secretion detection, imaging, and therapy.
Collapse
Affiliation(s)
| | | | | | | | | | - Chunsheng Wang
- Department of Cardiovascular Surgery, Zhongshan Hospital Fudan University, Shanghai 200032, China; (T.Y.); (F.W.); (Y.M.); (S.Z.); (M.Z.)
| | - Changfa Guo
- Department of Cardiovascular Surgery, Zhongshan Hospital Fudan University, Shanghai 200032, China; (T.Y.); (F.W.); (Y.M.); (S.Z.); (M.Z.)
| | - Kai Zhu
- Department of Cardiovascular Surgery, Zhongshan Hospital Fudan University, Shanghai 200032, China; (T.Y.); (F.W.); (Y.M.); (S.Z.); (M.Z.)
| |
Collapse
|
9
|
Obeidat YM, Bany Hamad N, Rawashdeh AM. A solid state electrolyte based enzymatic acetone sensor. Sci Rep 2024; 14:15461. [PMID: 38965300 PMCID: PMC11224388 DOI: 10.1038/s41598-024-66498-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Accepted: 07/02/2024] [Indexed: 07/06/2024] Open
Abstract
This paper introduces a novel solid-state electrolyte-based enzymatic sensor designed for the detection of acetone, along with an examination of its performance under various surface modifications aimed at optimizing its sensing capabilities. To measure acetone concentrations in both liquid and vapor states, cyclic voltammetry and amperometry techniques were employed, utilizing disposable screen-printed electrodes consisting of a platinum working electrode, a platinum counter electrode, and a silver reference electrode. Four different surface modifications, involving different combinations of Nafion (N) and enzyme (E) layers (N + E; N + E + N; N + N + E; N + N + E + N), were tested to identify the most effective configuration for a sensor that can be used for breath acetone detection. The sensor's essential characteristics, including linearity, sensitivity, reproducibility, and limit of detection, were thoroughly evaluated through a range of experiments spanning concentrations from 1 µM to 25 mM. Changes in acetone concentration were monitored by comparing currents readings at different acetone concentrations. The sensor exhibited high sensitivity, and a linear response to acetone concentration in both liquid and gas phases within the specified concentration range, with correlation coefficients ranging from 0.92 to 0.98. Furthermore, the sensor achieved a rapid response time of 30-50 s and an impressive detection limit as low as 0.03 µM. The results indicated that the sensor exhibited the best linearity, sensitivity, and limit of detection when four layers were employed (N + N + E + N).
Collapse
Affiliation(s)
- Yusra M Obeidat
- Department of Electronics Engineering, Hijjawi Faculty for Engineering Technology, Yarmouk University, Irbid, Jordan.
| | - Nour Bany Hamad
- Department of Chemistry, Faculty of Science and Arts, JUST University, Irbid, Jordan
| | - Abdel Monem Rawashdeh
- Department of Chemistry, Faculty of Sciences, Yarmouk University, P.O. Box 566, Irbid, Jordan
| |
Collapse
|
10
|
Sakane N. Innovations and applications of ketone body monitoring in diabetes care. Diabetol Int 2024; 15:370-378. [PMID: 39101172 PMCID: PMC11291811 DOI: 10.1007/s13340-024-00735-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Accepted: 05/18/2024] [Indexed: 08/06/2024]
Abstract
Ketone bodies, comprising β-hydroxybutyric acid (BHB), acetoacetate (AcAc), and acetone, play a vital role as essential energy substrates. In individuals with diabetes, ketone bodies can be elevated under various conditions, including diabetic ketoacidosis, use of sodium-glucose transporter type 2 (SGLT2) inhibitors, and extreme carbohydrate restriction. There are three methods for measuring ketone bodies. Urine ketone analysis (AcAc) is a standard clinical test, whereas blood ketone testing (BHB+AcAc) is valuable in identifying or resolving diabetic ketoacidosis. Recently, technology for measuring breath acetone has been introduced, which provides an easy means of monitoring ketogenic diets in obese individuals. The basic breath alcohol detector also reacts with breath acetone. Therefore, it is important for professional drivers taking SGLT2 inhibitors to be cautious as workplace breath alcohol detectors may show false-positive results. Conversely, if a positive result is obtained, a detailed examination of ketosis is necessary. This review provides an overview of ketone body measurements in individuals with diabetes.
Collapse
Affiliation(s)
- Naoki Sakane
- Division of Preventive Medicine, Clinical Research Institute, National Hospital Organization Kyoto Medical Center, 1-1 Mukaihata-cho, Fukakusa, Fushimi-ku, Kyoto, 612-8555 Japan
| |
Collapse
|
11
|
Wang S, Jiao C, Gerlach G, Körner J. Porosity Engineering of Dried Smart Poly( N-isopropylacrylamide) Hydrogels for Gas Sensing. Biomacromolecules 2024; 25:2715-2727. [PMID: 38047737 PMCID: PMC11094736 DOI: 10.1021/acs.biomac.3c00738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2023] [Revised: 11/18/2023] [Accepted: 11/20/2023] [Indexed: 12/05/2023]
Abstract
A recent study unveiled the potential of acrylamide-based stimulus-responsive hydrogels for volatile organic compound detection in gaseous environments. However, for gas sensing, a large surface area, that is, a highly porous material, offering many adsorption sites is crucial. The large humidity variation in the gaseous environment constitutes a significant challenge for preserving an initially porous structure, as the pores tend to be unstable and irreversibly collapse. Therefore, the present investigation focuses on enhancing the porosity of smart PNiPAAm hydrogels under the conditions of a gaseous environment and the preservation of the structural integrity for long-term use. We have studied the influence of polyethylene glycol (PEG) as a porogen and the application of different drying methods and posttreatment. The investigations lead to the conclusion that only the combination of PEG addition, freeze-drying, and subsequent conditioning in high relative humidity enables a long-term stable formation of a porous surface and inner structure of the material. The significantly enhanced swelling response in a gaseous environment and in the test gas acetone is confirmed by gravimetric experiments of bulk samples and continuous measurements of thin films on piezoresistive pressure sensor chips. These measurements are furthermore complemented by an in-depth analysis of the morphology and microstructure. While the study was conducted for PNiPAAm, the insights and developed processes are general in nature and can be applied for porosity engineering of other smart hydrogel materials for VOC detection in gaseous environments.
Collapse
Affiliation(s)
- Sitao Wang
- Institute
of Solid-State Electronics, Dresden University
of Technology, 01062 Dresden, Germany
| | - Chen Jiao
- Leibniz-Institut
für Polymerforschung Dresden e.V., Hohe Straße 6, 01069 Dresden, Germany
| | - Gerald Gerlach
- Institute
of Solid-State Electronics, Dresden University
of Technology, 01062 Dresden, Germany
| | - Julia Körner
- Institute
of Electrical Engineering and Measurement Technology, Leibniz Universität Hannover, 30167 Hannover, Germany
| |
Collapse
|
12
|
Molinier B, Arata C, Katz EF, Lunderberg DM, Ofodile J, Singer BC, Nazaroff WW, Goldstein AH. Bedroom Concentrations and Emissions of Volatile Organic Compounds during Sleep. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:7958-7967. [PMID: 38656997 PMCID: PMC11080066 DOI: 10.1021/acs.est.3c10841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 04/09/2024] [Accepted: 04/10/2024] [Indexed: 04/26/2024]
Abstract
Because humans spend about one-third of their time asleep in their bedrooms and are themselves emission sources of volatile organic compounds (VOCs), it is important to specifically characterize the composition of the bedroom air that they experience during sleep. This work uses real-time indoor and outdoor measurements of volatile organic compounds (VOCs) to examine concentration enhancements in bedroom air during sleep and to calculate VOC emission rates associated with sleeping occupants. Gaseous VOCs were measured with proton-transfer reaction time-of-flight mass spectrometry during a multiweek residential monitoring campaign under normal occupancy conditions. Results indicate high emissions of nearly 100 VOCs and other species in the bedroom during sleeping periods as compared to the levels in other rooms of the same residence. Air change rates for the bedroom and, correspondingly, emission rates of sleeping-associated VOCs were determined for two bounding conditions: (1) air exchange between the bedroom and outdoors only and (2) air exchange between the bedroom and other indoor spaces only (as represented by measurements in the kitchen). VOCs from skin oil oxidation and personal care products were present, revealing that many emission pathways can be important occupant-associated emission factors affecting bedroom air composition in addition to direct emissions from building materials and furnishings.
Collapse
Affiliation(s)
- Betty Molinier
- Department
of Civil and Environmental Engineering, University of California, Berkeley, California 94720, United States
| | - Caleb Arata
- Department
of Chemistry, University of California, Berkeley, California 94720, United States
- Department
of Environmental Science, Policy and Management, University of California, Berkeley, California 94720, United States
| | - Erin F. Katz
- Department
of Chemistry, University of California, Berkeley, California 94720, United States
| | - David M. Lunderberg
- Department
of Chemistry, University of California, Berkeley, California 94720, United States
- Department
of Environmental Science, Policy and Management, University of California, Berkeley, California 94720, United States
| | - Jennifer Ofodile
- Department
of Environmental Science, Policy and Management, University of California, Berkeley, California 94720, United States
| | - Brett C. Singer
- Indoor
Environment Group and Residential Building Systems Group, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| | - William W Nazaroff
- Department
of Civil and Environmental Engineering, University of California, Berkeley, California 94720, United States
| | - Allen H. Goldstein
- Department
of Civil and Environmental Engineering, University of California, Berkeley, California 94720, United States
- Department
of Environmental Science, Policy and Management, University of California, Berkeley, California 94720, United States
| |
Collapse
|
13
|
Wei S, Li Z, Murugappan K, Li Z, Lysevych M, Vora K, Tan HH, Jagadish C, Karawdeniya BI, Nolan CJ, Tricoli A, Fu L. Nanowire Array Breath Acetone Sensor for Diabetes Monitoring. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2309481. [PMID: 38477429 PMCID: PMC11109654 DOI: 10.1002/advs.202309481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 02/18/2024] [Indexed: 03/14/2024]
Abstract
Diabetic ketoacidosis (DKA) is a life-threatening acute complication of diabetes characterized by the accumulation of ketone bodies in the blood. Breath acetone, a ketone, directly correlates with blood ketones. Therefore, monitoring breath acetone can significantly enhance the safety and efficacy of diabetes care. In this work, the design and fabrication of an InP/Pt/chitosan nanowire array-based chemiresistive acetone sensor is reported. By incorporation of chitosan as a surface-functional layer and a Pt Schottky contact for efficient charge transfer processes and photovoltaic effect, self-powered, highly selective acetone sensing is achieved. The sensor has exhibited an ultra-wide acetone detection range from sub-ppb to >100 000 ppm level at room temperature, covering those in the exhaled breath from healthy individuals (300-800 ppb) to people at high risk of DKA (>75 ppm). The nanowire sensor has also been successfully integrated into a handheld breath testing prototype, the Ketowhistle, which can successfully detect different ranges of acetone concentrations in simulated breath samples. The Ketowhistle demonstrates the immediate potential for non-invasive ketone monitoring for people living with diabetes, in particular for DKA prevention.
Collapse
Affiliation(s)
- Shiyu Wei
- Australian Research Council Centre of Excellence for Transformative Meta‐Optical SystemsDepartment of Electronic Materials EngineeringResearch School of PhysicsThe Australian National UniversityCanberraACT2600Australia
| | - Zhe Li
- Australian Research Council Centre of Excellence for Transformative Meta‐Optical SystemsDepartment of Electronic Materials EngineeringResearch School of PhysicsThe Australian National UniversityCanberraACT2600Australia
| | - Krishnan Murugappan
- Commonwealth Scientific and Industrial Research Organisation (CSIRO)Mineral ResourcesPrivate Bag 10Clayton SouthVIC3169Australia
- Nanotechnology Research LaboratoryResearch School of ChemistryCollege of ScienceThe Australian National UniversityCanberraACT2600Australia
| | - Ziyuan Li
- Australian Research Council Centre of Excellence for Transformative Meta‐Optical SystemsDepartment of Electronic Materials EngineeringResearch School of PhysicsThe Australian National UniversityCanberraACT2600Australia
| | - Mykhaylo Lysevych
- Australian National Fabrication FacilityThe Australian National UniversityCanberraACT2600Australia
| | - Kaushal Vora
- Australian National Fabrication FacilityThe Australian National UniversityCanberraACT2600Australia
| | - Hark Hoe Tan
- Australian Research Council Centre of Excellence for Transformative Meta‐Optical SystemsDepartment of Electronic Materials EngineeringResearch School of PhysicsThe Australian National UniversityCanberraACT2600Australia
| | - Chennupati Jagadish
- Australian Research Council Centre of Excellence for Transformative Meta‐Optical SystemsDepartment of Electronic Materials EngineeringResearch School of PhysicsThe Australian National UniversityCanberraACT2600Australia
| | - Buddini I Karawdeniya
- Australian Research Council Centre of Excellence for Transformative Meta‐Optical SystemsDepartment of Electronic Materials EngineeringResearch School of PhysicsThe Australian National UniversityCanberraACT2600Australia
| | - Christopher J Nolan
- School of Medicine and PsychologyCollege of Health and MedicineThe Australian National UniversityCanberraACT2600Australia
- Department of Diabetes and EndocrinologyThe Canberra HospitalGarranACT2605Australia
| | - Antonio Tricoli
- Nanotechnology Research LaboratoryResearch School of ChemistryCollege of ScienceThe Australian National UniversityCanberraACT2600Australia
- Nanotechnology Research LaboratoryFaculty of EngineeringThe University of SydneyCamperdown2006Australia
| | - Lan Fu
- Australian Research Council Centre of Excellence for Transformative Meta‐Optical SystemsDepartment of Electronic Materials EngineeringResearch School of PhysicsThe Australian National UniversityCanberraACT2600Australia
| |
Collapse
|
14
|
Glöckler J, Jaeschke C, Padilla M, Mitrovics J, Mizaikoff B. Ultratrace eNose Sensing of VOCs toward Breath Analysis Applications Utilizing an eNose-Based Analyzer. ACS MEASUREMENT SCIENCE AU 2024; 4:184-187. [PMID: 38645578 PMCID: PMC11027196 DOI: 10.1021/acsmeasuresciau.3c00053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 01/11/2024] [Accepted: 01/16/2024] [Indexed: 04/23/2024]
Abstract
This proof-of-principle study presents the ability of the recently developed iLovEnose to measure ultratrace levels of volatile organic compounds (VOCs) in simulated human breath based on the combination of multiple gas sensors. The iLovEnose was developed by our research team as a test bed for gas sensors that can be hosted in three serially connected compact low-volume and temperature-controlled compartments. Herein, the eNose system was equipped with conventional semiconducting metal oxide (MOX) gas sensors using a variety of base technologies providing 11 different sensor signals that were evaluated to determine six VOCs of interest at eight low to ultralow concentration levels (i.e., ranging from 3 to 0.075 ppm) at humid conditions (90% rh at 22 °C). The measurements were randomized and performed four times over a period of 2 weeks. Partial least-squares regression analysis was applied to estimate the concentration of these six analytes. It was shown that the iLovEnose system is able to discriminate between these VOCs and provide reliable quantitative information relevant for future applications in exhaled breath analysis as a diagnostic disease detection or monitoring device.
Collapse
Affiliation(s)
- Johannes Glöckler
- Institute
of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | - Carsten Jaeschke
- Institute
of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | - Marta Padilla
- JLM
Innovation GmbH, Vor
dem Kreuzberg 17, 72070 Tübingen, Germany
| | - Jan Mitrovics
- JLM
Innovation GmbH, Vor
dem Kreuzberg 17, 72070 Tübingen, Germany
| | - Boris Mizaikoff
- Institute
of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
- Hahn-Schickard, Sedanstrasse
14, 89077 Ulm, Germany
| |
Collapse
|
15
|
Oghenetega O, Fulvio P, Bobbitt NS, Walton KS. Single-Component Adsorption Equilibria of CO 2, CH 4, Water, and Acetone on Tapered Porous Carbon Molecular Sieves. JOURNAL OF CHEMICAL AND ENGINEERING DATA 2024; 69:1411-1422. [PMID: 38505328 PMCID: PMC10945479 DOI: 10.1021/acs.jced.3c00368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 10/17/2023] [Accepted: 10/30/2023] [Indexed: 03/21/2024]
Abstract
Engineered carbon molecular sieves (CMSs) with tapered pores, high surface area, and high total pore volume were investigated for their CO2, CH4, water, and acetone adsorption properties at 288.15, 298.15, 308.15 K, and pressures of <1 bar. The results were compared with BPL carbon. The samples exhibited higher adsorption capacity for CO2 compared to BPL carbon, with Carboxen 1005 being the highest due to the presence of ultramicropores (pores smaller than 0.8 nm). Similar observations were made for CH4 except at 288.15 K. Although the CMSs exhibited higher hydrophobicity than BPL carbon, the latter had the highest acetone uptake for all investigated temperatures due to its higher oxygen content, which facilitates stronger interactions with polar VOC molecules. Heats of adsorption were calculated using the Clausius-Clapeyron equation after fitting the isotherms with the dual-site Langmuir-Freundlich model, and results largely corroborated the order of adsorption capacities of CO2, CH4, and water on the carbon materials.
Collapse
Affiliation(s)
- Ojuolape
O. Oghenetega
- School
of Chemical & Biomolecular Engineering Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Pasquale Fulvio
- School
of Chemical & Biomolecular Engineering Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - N. Scott Bobbitt
- Sandia
National Laboratories, Albuquerque, New Mexico 87185, United States
| | - Krista S. Walton
- School
of Chemical & Biomolecular Engineering Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| |
Collapse
|
16
|
Das P, Marvi PK, Ganguly S, Tang XS, Wang B, Srinivasan S, Rajabzadeh AR, Rosenkranz A. MXene-Based Elastomer Mimetic Stretchable Sensors: Design, Properties, and Applications. NANO-MICRO LETTERS 2024; 16:135. [PMID: 38411801 PMCID: PMC10899156 DOI: 10.1007/s40820-024-01349-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Accepted: 01/09/2024] [Indexed: 02/28/2024]
Abstract
Flexible sensors based on MXene-polymer composites are highly prospective for next-generation wearable electronics used in human-machine interfaces. One of the motivating factors behind the progress of flexible sensors is the steady arrival of new conductive materials. MXenes, a new family of 2D nanomaterials, have been drawing attention since the last decade due to their high electronic conductivity, processability, mechanical robustness and chemical tunability. In this review, we encompass the fabrication of MXene-based polymeric nanocomposites, their structure-property relationship, and applications in the flexible sensor domain. Moreover, our discussion is not only limited to sensor design, their mechanism, and various modes of sensing platform, but also their future perspective and market throughout the world. With our article, we intend to fortify the bond between flexible matrices and MXenes thus promoting the swift advancement of flexible MXene-sensors for wearable technologies.
Collapse
Affiliation(s)
- Poushali Das
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON, L8S 4L8, Canada
| | - Parham Khoshbakht Marvi
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON, L8S 4L8, Canada
| | - Sayan Ganguly
- Department of Chemistry and Waterloo Institute for Nanotechnology (WIN), University of Waterloo, 200 University Ave West, Waterloo, ON, Canada
- Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Shatin, Hong Kong, People's Republic of China
| | - Xiaowu Shirley Tang
- Department of Chemistry and Waterloo Institute for Nanotechnology (WIN), University of Waterloo, 200 University Ave West, Waterloo, ON, Canada
- Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Shatin, Hong Kong, People's Republic of China
| | - Bo Wang
- Chair of Functional Materials, Department of Materials Science and Engineering, Saarland University, Saarbrücken, Germany
| | - Seshasai Srinivasan
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON, L8S 4L8, Canada.
- W Booth School of Engineering Practice and Technology, McMaster University, 1280 Main Street West, Hamilton, ON, L8S 4L7, Canada.
| | - Amin Reza Rajabzadeh
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON, L8S 4L8, Canada.
- W Booth School of Engineering Practice and Technology, McMaster University, 1280 Main Street West, Hamilton, ON, L8S 4L7, Canada.
| | - Andreas Rosenkranz
- Department for Chemical Engineering, Biotechnology and Materials, University of Chile, Santiago, Chile.
| |
Collapse
|
17
|
Bajo-Fernández M, Souza-Silva ÉA, Barbas C, Rey-Stolle MF, García A. GC-MS-based metabolomics of volatile organic compounds in exhaled breath: applications in health and disease. A review. Front Mol Biosci 2024; 10:1295955. [PMID: 38298553 PMCID: PMC10828970 DOI: 10.3389/fmolb.2023.1295955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 12/05/2023] [Indexed: 02/02/2024] Open
Abstract
Exhaled breath analysis, with particular emphasis on volatile organic compounds, represents a growing area of clinical research due to its obvious advantages over other diagnostic tests. Numerous pathologies have been extensively investigated for the identification of specific biomarkers in exhalates through metabolomics. However, the transference of breath tests to clinics remains limited, mainly due to deficiency in methodological standardization. Critical steps include the selection of breath sample types, collection devices, and enrichment techniques. GC-MS is the reference analytical technique for the analysis of volatile organic compounds in exhalates, especially during the biomarker discovery phase in metabolomics. This review comprehensively examines and compares metabolomic studies focusing on cancer, lung diseases, and infectious diseases. In addition to delving into the experimental designs reported, it also provides a critical discussion of the methodological aspects, ranging from the experimental design and sample collection to the identification of potential pathology-specific biomarkers.
Collapse
Affiliation(s)
- María Bajo-Fernández
- Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
| | - Érica A. Souza-Silva
- Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
- Departmento de Química, Universidade Federal de São Paulo (UNIFESP), Diadema, Brazil
| | - Coral Barbas
- Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
| | - Ma Fernanda Rey-Stolle
- Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
| | - Antonia García
- Centro de Metabolómica y Bioanálisis (CEMBIO), Facultad de Farmacia, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain
| |
Collapse
|
18
|
Schanzmann H, Ruzsanyi V, Ahmad-Nejad P, Telgheder U, Sielemann S. A novel coupling technique based on thermal desorption gas chromatography with mass spectrometry and ion mobility spectrometry for breath analysis. J Breath Res 2023; 18:016009. [PMID: 38100823 DOI: 10.1088/1752-7163/ad1615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Accepted: 12/15/2023] [Indexed: 12/17/2023]
Abstract
Exhaled breath analysis is evolving into an increasingly important non-invasive diagnostic tool. Volatile organic compounds (VOCs) in breath contain information about health status and are promising biomarkers for several diseases, including respiratory infections caused by bacteria. To monitor the composition of VOCs in breath or the emission of VOCs from bacteria, sensitive analytical techniques are required. Next to mass spectrometry, ion mobility spectrometry (IMS) is considered a promising analytical tool for detecting gaseous analytes in the parts per billion by volume to parts per trillion by volume range. This work presents a new, dual coupling of thermal desorption gas chromatography to a quadrupole mass spectrometer (MS) and an IMS by operating a simple splitter. Nearly identical retention times can be reached in the range of up to 30 min with slight deviations of 0.06 min-0.24 min. This enables the identification of unknown compounds in the IMS chromatogram using unambiguous mass spectral identification, as there are still no commercially available databases for IMS. It is also possible to discriminate one of the detectors using the splitter to improve detection limits. Using a test liquid mixture of seven ketones, namely 2-butanone, 2-pentanone, 2-hexanone, 2-heptanone, 2-octanone, 2-nonanone, and 2-decanone with a concentration of 0.01 g l-1reproducibilities ranging from 3.0% to 7.6% for MS and 2.2%-5.3%, for IMS were obtained, respectively. In order to test the system optimized here for the field of breath analysis, characteristic VOCs such as ethanol, isoprene, acetone, 2-propanol, and 1-propanol were successfully identified in exhaled air using the dual detector system due to the match of the corresponding IMS, and MS spectra. The presented results may be considered to be a starting point for the greater use of IMS in combination with MS within the medical field.
Collapse
Affiliation(s)
- Hannah Schanzmann
- Laboratory of Applied Instrumental Analytical Chemistry, Hamm-Lippstadt University of Applied Sciences, Hamm, Germany
- Faculty of Chemistry, Instrumental Analytical Chemistry, University of Duisburg-Essen, Essen, Germany
- Institute for Medical Laboratory Diagnostics, Center for Clinical and Translational Research, Helios University Hospital Wuppertal, Witten/Herdecke University, Wuppertal, Germany
| | - Veronika Ruzsanyi
- Institute for Breath Research, Leopold-Franzens-Universität Innsbruck, Innsbruck, Austria
| | - Parviz Ahmad-Nejad
- Institute for Medical Laboratory Diagnostics, Center for Clinical and Translational Research, Helios University Hospital Wuppertal, Witten/Herdecke University, Wuppertal, Germany
| | - Ursula Telgheder
- Faculty of Chemistry, Instrumental Analytical Chemistry, University of Duisburg-Essen, Essen, Germany
| | - Stefanie Sielemann
- Laboratory of Applied Instrumental Analytical Chemistry, Hamm-Lippstadt University of Applied Sciences, Hamm, Germany
| |
Collapse
|
19
|
Osorio Perez O, Nguyen NA, Hendricks A, Victor S, Mora SJ, Yu N, Xian X, Wang S, Kulick D, Forzani E. A Novel Acetone Sensor for Body Fluids. BIOSENSORS 2023; 14:4. [PMID: 38248381 PMCID: PMC10813317 DOI: 10.3390/bios14010004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 12/10/2023] [Accepted: 12/11/2023] [Indexed: 01/23/2024]
Abstract
Ketones are well-known biomarkers of fat oxidation produced in the liver as a result of lipolysis. These biomarkers include acetoacetic acid and β-hydroxybutyric acid in the blood/urine and acetone in our breath and skin. Monitoring ketone production in the body is essential for people who use caloric intake deficit to reduce body weight or use ketogenic diets for wellness or therapeutic treatments. Current methods to monitor ketones include urine dipsticks, capillary blood monitors, and breath analyzers. However, these existing methods have certain disadvantages that preclude them from being used more widely. In this work, we introduce a novel acetone sensor device that can detect acetone levels in breath and overcome the drawbacks of existing sensing approaches. The critical element of the device is a robust sensor with the capability to measure acetone using a complementary metal oxide semiconductor (CMOS) chip and convenient data analysis from a red, green, and blue deconvolution imaging approach. The acetone sensor device demonstrated sensitivity of detection in the micromolar-concentration range, selectivity for detection of acetone in breath, and a lifetime stability of at least one month. The sensor device utility was probed with real tests on breath samples using an established blood ketone reference method.
Collapse
Affiliation(s)
- Oscar Osorio Perez
- School of Engineering for Matter, Transport and Energy, Arizona State University, Tempe, AZ 85287, USA; (O.O.P.); (N.A.N.); (A.H.)
- Center for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, 1001 S McAllister Ave., Tempe, AZ 85281, USA; (S.V.); (S.J.M.); (N.Y.); (X.X.); (S.W.)
| | - Ngan Anh Nguyen
- School of Engineering for Matter, Transport and Energy, Arizona State University, Tempe, AZ 85287, USA; (O.O.P.); (N.A.N.); (A.H.)
- Center for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, 1001 S McAllister Ave., Tempe, AZ 85281, USA; (S.V.); (S.J.M.); (N.Y.); (X.X.); (S.W.)
| | - Asher Hendricks
- School of Engineering for Matter, Transport and Energy, Arizona State University, Tempe, AZ 85287, USA; (O.O.P.); (N.A.N.); (A.H.)
- Center for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, 1001 S McAllister Ave., Tempe, AZ 85281, USA; (S.V.); (S.J.M.); (N.Y.); (X.X.); (S.W.)
| | - Shaun Victor
- Center for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, 1001 S McAllister Ave., Tempe, AZ 85281, USA; (S.V.); (S.J.M.); (N.Y.); (X.X.); (S.W.)
| | - Sabrina Jimena Mora
- Center for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, 1001 S McAllister Ave., Tempe, AZ 85281, USA; (S.V.); (S.J.M.); (N.Y.); (X.X.); (S.W.)
| | - Nanxi Yu
- Center for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, 1001 S McAllister Ave., Tempe, AZ 85281, USA; (S.V.); (S.J.M.); (N.Y.); (X.X.); (S.W.)
- School of Molecular Sciences, Arizona State University, Tempe, AZ 85287, USA
| | - Xiaojun Xian
- Center for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, 1001 S McAllister Ave., Tempe, AZ 85281, USA; (S.V.); (S.J.M.); (N.Y.); (X.X.); (S.W.)
- Department of Electrical Engineering and Computer Science, South Dakota State University, Brookings, SD 57007, USA
| | - Shaopeng Wang
- Center for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, 1001 S McAllister Ave., Tempe, AZ 85281, USA; (S.V.); (S.J.M.); (N.Y.); (X.X.); (S.W.)
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ 85287, USA
| | | | - Erica Forzani
- School of Engineering for Matter, Transport and Energy, Arizona State University, Tempe, AZ 85287, USA; (O.O.P.); (N.A.N.); (A.H.)
- Center for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, 1001 S McAllister Ave., Tempe, AZ 85281, USA; (S.V.); (S.J.M.); (N.Y.); (X.X.); (S.W.)
- Mayo Clinic, Scottsdale, AZ 85289, USA;
| |
Collapse
|
20
|
Sánchez F, Gutiérrez M, Douhal A. Taking Advantage of a Luminescent ESIPT-Based Zr-MOF for Fluorochromic Detection of Multiple External Stimuli: Acid and Base Vapors, Mechanical Compression, and Temperature. ACS APPLIED MATERIALS & INTERFACES 2023; 15:56587-56599. [PMID: 37983009 DOI: 10.1021/acsami.3c14348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2023]
Abstract
Luminescent materials responsive to external stimuli have captivated great attention owing to their potential implementation in noninvasive photonic sensors. Luminescent metal-organic frameworks (LMOFs), a type of porous crystalline material, have emerged as one of the most promising candidates for these applications. Moreover, LMOFs constructed with organic linkers that undergo excited-state intramolecular proton-transfer (ESIPT) reactions are particularly relevant since changes in the surrounding environment induce modifications in their emission properties. Herein, an ESIPT-based LMOF, UiO-66-(OH)2, has been synthesized, spectroscopically and photodynamically characterized, and tested for detecting multiple external stimuli. First, the spectroscopic and photodynamic characterization of the organic linker (2,5-dihydroxyterephthalic acid (DHT)) and the UiO-66-(OH)2 MOF demonstrates that the emission properties are mainly governed by the enol → keto tautomerization, occurring in the organic linker via the ESIPT reaction. Afterward, the UiO-66-(OH)2 MOF proves for the first time to be a promising candidate to detect vapors of acid (HCl) and base (Et3N) toxic chemicals, changes in the mechanical compression (exercised pressure), and changes in the temperature. These results shed light on the potential of ESIPT-based LMOFs to be implemented in the development of advanced optical materials and luminescent sensors.
Collapse
Affiliation(s)
- Francisco Sánchez
- Departamento de Química Física, Facultad de Ciencias Ambientales y Bioquímica, INAMOL, Universidad de Castilla-La Mancha, Avenida Carlos III, S/N, 45071 Toledo, Spain
| | - Mario Gutiérrez
- Departamento de Química Física, Facultad de Ciencias Ambientales y Bioquímica, INAMOL, Universidad de Castilla-La Mancha, Avenida Carlos III, S/N, 45071 Toledo, Spain
| | - Abderrazzak Douhal
- Departamento de Química Física, Facultad de Ciencias Ambientales y Bioquímica, INAMOL, Universidad de Castilla-La Mancha, Avenida Carlos III, S/N, 45071 Toledo, Spain
| |
Collapse
|
21
|
Kistenev YV, Borisov AV, Zasedatel VS, Spirina LV. Diabetes noninvasive diagnostics and monitoring through volatile biomarkers analysis in the exhaled breath using optical absorption spectroscopy. JOURNAL OF BIOPHOTONICS 2023; 16:e202300198. [PMID: 37643222 DOI: 10.1002/jbio.202300198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 08/22/2023] [Accepted: 08/22/2023] [Indexed: 08/31/2023]
Abstract
The review is aimed on the analysis the abilities of noninvasive diagnostics and monitoring of diabetes mellitus (DM) and DM-associated complications through volatile molecular biomarkers detection in the exhaled breath. The specific biochemical reactions in the body of DM patients and their associations with volatile molecular biomarkers in the breath are considered. The applications of optical spectroscopy methods, including UV, IR, and terahertz spectroscopy for DM-associated volatile molecular biomarkers measurements, are described. The applications of similar technique combined with machine learning methods in DM diagnostics using the profile of DM-associated volatile molecular biomarkers in exhaled air or "pattern-recognition" approach are discussed.
Collapse
Affiliation(s)
- Yury V Kistenev
- Laboratory of Laser Molecular Imaging and Machine Learning, Tomsk State University, Tomsk, Russia
- Laboratory for Remote Sensing of the Environment, V.E. Zuev Institute of Atmospheric Optics SB RAS, Tomsk, Russia
| | - Alexey V Borisov
- Laboratory of Laser Molecular Imaging and Machine Learning, Tomsk State University, Tomsk, Russia
| | - Vyacheslav S Zasedatel
- Laboratory of Laser Molecular Imaging and Machine Learning, Tomsk State University, Tomsk, Russia
| | - Liudmila V Spirina
- Division of Biochemistry and Molecular Biology, Siberian State Medical University, Tomsk, Russia
- Laboratory of Tumor Biochemistry, Cancer Research Institute, National Research Medical Center, Tomsk, Russia
| |
Collapse
|
22
|
Prakash Biswal D, Singha D, Panda J, Kumar Rana M. Post-Synthetic Modification of Zr-based Metal-Organic Frameworks with Imidazole: Variable Optical Behavior and Sensing. Chemphyschem 2023; 24:e202300311. [PMID: 37578308 DOI: 10.1002/cphc.202300311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 08/11/2023] [Accepted: 08/14/2023] [Indexed: 08/15/2023]
Abstract
UiO-66-NH2 -IM, a fluorescent metal-organic framework (MOF), was synthesized by post-synthetic modification of UiO-66-NH2 with 2-imidazole carboxaldehyde via a Schiff base reaction. It was examined using various characterization techniques (PXRD, FTIR, NMR, SEM, TGA, UV-Vis DRS, and photoluminescence spectroscopy). The emissive feature of UiO-66-NH2 -IM was utilized to detect volatile organic compounds (VOCs), metal ions, and anions, such as acetone, Fe3+ , and carbonate (CO3 2- ). Acetone turns off the high luminescence of UiO-66-NH2 -IM in DMSO, with the limit of detection (LOD) being 3.6 ppm. Similarly, Fe3+ in an aqueous medium is detected at LOD=0.67 μM (0.04 ppm) via quenching. On the contrary, CO3 2- in an aqueous medium significantly enhances the luminescence of UiO-66-NH2 -IM, which is detected with extremely high sensitivity (LOD=1.16 μM, i. e., 0.07 ppm). Large Stern-Volmer constant, Ksv , and low LOD values indicate excellent sensitivity of the post-synthetic MOF. Experimental data supported by density functional theory (DFT) calculations discern photo-induced electron transfer (PET), resonance energy transfer (RET), inner filter effect (IFE), or proton abstraction as putative sensing mechanisms. NMR and computational studies propose a proton abstraction mechanism for luminescence enhancement with CO3 2- . Moreover, the optical behavior of the post-synthetic material toward analytes is recyclable.
Collapse
Affiliation(s)
- Dibya Prakash Biswal
- Department of Chemical Sciences, Indian Institute of Science Education and Research (IISER), Berhampur, Berhampur, 760010, Odisha, India
| | - Dipankar Singha
- Department of Chemical Sciences, Indian Institute of Science Education and Research (IISER), Berhampur, Berhampur, 760010, Odisha, India
| | - Jagannath Panda
- Department of Chemical Sciences, Indian Institute of Science Education and Research (IISER), Berhampur, Berhampur, 760010, Odisha, India
| | - Malay Kumar Rana
- Department of Chemical Sciences, Indian Institute of Science Education and Research (IISER), Berhampur, Berhampur, 760010, Odisha, India
| |
Collapse
|
23
|
Nyabadza A, McCarthy É, Makhesana M, Heidarinassab S, Plouze A, Vazquez M, Brabazon D. A review of physical, chemical and biological synthesis methods of bimetallic nanoparticles and applications in sensing, water treatment, biomedicine, catalysis and hydrogen storage. Adv Colloid Interface Sci 2023; 321:103010. [PMID: 37804661 DOI: 10.1016/j.cis.2023.103010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 08/30/2023] [Accepted: 09/24/2023] [Indexed: 10/09/2023]
Abstract
This article provides an in-depth analysis of various fabrication methods of bimetallic nanoparticles (BNP), including chemical, biological, and physical techniques. The review explores BNP's diverse uses, from well-known applications such as sensing water treatment and biomedical uses to less-studied areas like breath sensing for diabetes monitoring and hydrogen storage. It cites results from over 1000 researchers worldwide and >300 peer-reviewed articles. Additionally, the article discusses current trends, actionable recommendations, and the importance of synthetic analysis for industry players looking to optimize manufacturing techniques for specific applications. The article also evaluates the pros and cons of various fabrication methods, highlighting the potential of plant extract synthesis for mass production of capped BNPs. However, it warns that this method may not be suitable for certain applications requiring ligand-free surfaces. In contrast, physical methods like laser ablation offer better control and reactivity, especially for applications where ligand-free surfaces are critical. The report underscores the environmental benefits of plant extract synthesis compared to chemical methods that use hazardous chemicals and pose risks to extraction, production, and disposal. The article emphasizes the need for life cycle assessment (LCA) articles in the literature, given the growing volume of research on nanotechnology materials. This article caters to researchers at all stages and applies to various fields applying nanomaterials.
Collapse
Affiliation(s)
- Anesu Nyabadza
- I-Form Advanced Manufacturing Centre Research, Dublin City University, Glasnevin, Dublin 9, Ireland; EPSRC & SFI Centre for Doctoral Training (CDT) in Advanced Metallic Systems, School of Mechanical & Manufacturing Engineering, School of Chemical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland; Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9, Ireland.
| | - Éanna McCarthy
- I-Form Advanced Manufacturing Centre Research, Dublin City University, Glasnevin, Dublin 9, Ireland; Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Mayur Makhesana
- Mechanical Engineering Department, Institute of Technology, Nirma University, Ahmedabad, Gujarat 382481, India
| | - Saeid Heidarinassab
- I-Form Advanced Manufacturing Centre Research, Dublin City University, Glasnevin, Dublin 9, Ireland; EPSRC & SFI Centre for Doctoral Training (CDT) in Advanced Metallic Systems, School of Mechanical & Manufacturing Engineering, School of Chemical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland; Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Anouk Plouze
- Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9, Ireland; Conservatoire National des arts et Métiers (CNAM), 61 Rue du Landy, 93210 Saint-Denis, France
| | - Mercedes Vazquez
- I-Form Advanced Manufacturing Centre Research, Dublin City University, Glasnevin, Dublin 9, Ireland; EPSRC & SFI Centre for Doctoral Training (CDT) in Advanced Metallic Systems, School of Mechanical & Manufacturing Engineering, School of Chemical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland; Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Dermot Brabazon
- I-Form Advanced Manufacturing Centre Research, Dublin City University, Glasnevin, Dublin 9, Ireland; EPSRC & SFI Centre for Doctoral Training (CDT) in Advanced Metallic Systems, School of Mechanical & Manufacturing Engineering, School of Chemical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland; Advanced Processing Technology Research Centre, Dublin City University, Glasnevin, Dublin 9, Ireland
| |
Collapse
|
24
|
Kimakova T, Kondrakhova D, Ovodok E, Ivanovskaya M, Kormosh V, Vorobiov S, Lisnichuk M, Bilanych V, Komanicky V. Sensors Based on Tin and Indium Oxides for the Determination of Acetone in Human Breath. ACS OMEGA 2023; 8:40078-40086. [PMID: 37929141 PMCID: PMC10620925 DOI: 10.1021/acsomega.3c02125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Accepted: 09/15/2023] [Indexed: 11/07/2023]
Abstract
The properties of planar sensors based on tin dioxide and indium oxide used for the determination of acetone vapors have been studied. Sensors based on synthesized SnO2 and In2O3 nanopowders showed high sensitivity to low concentrations of acetone in a humid environment which simulates human exhalation. The addition of a small amount of AuIII ions to hydroxide sols significantly increases the threshold sensitivity and the sensor response in a wide range of acetone concentrations. In2O3-Au sensors have the maximum sensitivity at an operating temperature of 325 °C. The In2O3-Au-sensors reliably record the change in acetone concentration in the concentration range from a minimum of 0.1 to 5 ppm with high accuracy, which is necessary for rapid diagnostics of the condition of patients with diabetes (1.8-5.0 ppm). The high sensitivity of the obtained sensors is explained by the structural features and the surface conditions of oxides and gold nanoparticles, which depend on the sample synthesis conditions.
Collapse
Affiliation(s)
- Tatiana Kimakova
- Faculty
of Medicine, Pavol Jozef Šafárik
University, Kosice 04001, Slovakia
| | - Daria Kondrakhova
- Faculty
of Science, Pavol Jozef Šafárik
University, Kosice 04001, Slovakia
| | - Evgeni Ovodok
- Research
Institute for Physical-Chemical Problems of the Belarusian State University, Minsk 220030, Belarus
| | - Marya Ivanovskaya
- Research
Institute for Physical-Chemical Problems of the Belarusian State University, Minsk 220030, Belarus
| | - Valentina Kormosh
- Research
Institute of Analytical Technique of Uzhhorod National University, Uzhhorod 88000, Ukraine
| | - Serhii Vorobiov
- Faculty
of Science, Pavol Jozef Šafárik
University, Kosice 04001, Slovakia
| | - Maksym Lisnichuk
- Faculty
of Science, Pavol Jozef Šafárik
University, Kosice 04001, Slovakia
| | - Vitalij Bilanych
- Faculty
of Science, Pavol Jozef Šafárik
University, Kosice 04001, Slovakia
- Faculty
of Physics, Uzhhorod National University, Uzhhorod 88000, Ukraine
| | - Vladimir Komanicky
- Faculty
of Science, Pavol Jozef Šafárik
University, Kosice 04001, Slovakia
| |
Collapse
|
25
|
Li Y, Wei X, Zhou Y, Wang J, You R. Research progress of electronic nose technology in exhaled breath disease analysis. MICROSYSTEMS & NANOENGINEERING 2023; 9:129. [PMID: 37829158 PMCID: PMC10564766 DOI: 10.1038/s41378-023-00594-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 08/16/2023] [Accepted: 08/17/2023] [Indexed: 10/14/2023]
Abstract
Exhaled breath analysis has attracted considerable attention as a noninvasive and portable health diagnosis method due to numerous advantages, such as convenience, safety, simplicity, and avoidance of discomfort. Based on many studies, exhaled breath analysis is a promising medical detection technology capable of diagnosing different diseases by analyzing the concentration, type and other characteristics of specific gases. In the existing gas analysis technology, the electronic nose (eNose) analysis method has great advantages of high sensitivity, rapid response, real-time monitoring, ease of use and portability. Herein, this review is intended to provide an overview of the application of human exhaled breath components in disease diagnosis, existing breath testing technologies and the development and research status of electronic nose technology. In the electronic nose technology section, the three aspects of sensors, algorithms and existing systems are summarized in detail. Moreover, the related challenges and limitations involved in the abovementioned technologies are also discussed. Finally, the conclusion and perspective of eNose technology are presented.
Collapse
Affiliation(s)
- Ying Li
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192 China
- Laboratory of Intelligent Microsystems, Beijing Information Science and Technology University, Beijing, 100192 China
| | - Xiangyang Wei
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192 China
- Laboratory of Intelligent Microsystems, Beijing Information Science and Technology University, Beijing, 100192 China
| | - Yumeng Zhou
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192 China
| | - Jing Wang
- School of Electronics and Information Engineering, Changchun University of Science and Technology, Changchun, 130022 China
| | - Rui You
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192 China
- Laboratory of Intelligent Microsystems, Beijing Information Science and Technology University, Beijing, 100192 China
| |
Collapse
|
26
|
Jang WB, Yi D, Nguyen TM, Lee Y, Lee EJ, Choi J, Kim YH, Choi EJ, Oh JW, Kwon SM. Artificial Neural Processing-Driven Bioelectronic Nose for the Diagnosis of Diabetes and Its Complications. Adv Healthc Mater 2023; 12:e2300845. [PMID: 37449876 DOI: 10.1002/adhm.202300845] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 07/10/2023] [Accepted: 07/11/2023] [Indexed: 07/18/2023]
Abstract
Diabetes and its complications affect the younger population and are associated with a high mortality rate; however, early diagnosis can contribute to the selection of appropriate treatment regimens that can reduce mortality. Although diabetes diagnosis via exhaled breath has great potential for early diagnosis, research on such diagnosis is restricted to disease detection, requiring in-depth examination to diagnose and classify diseases and their complications. This study demonstrates the use of an artificial neural processing-based bioelectronic nose to accurately diagnose diabetes and classify diabetic types (type I and II) and their complications, such as heart disease. Specifically, an M13 phage-based electronic nose (e-nose) is used to explore the features of subjects with diabetes at various levels of cellular and organismal organization (cells, liver organoids, and mice). Exhaled breath samples are collected during culturing and exposed to the phage-based e-nose. Compared with cells, liver organoids cultured under conditions mimicking a diabetic environment display properties that closely resemble the characteristics of diabetic mice. Using neural pattern separation, the M13 phage-based e-nose achieves a classification success rate of over 86% for four conditions in mice, namely, type 1 diabetes, type 2 diabetes, diabetic cardiomyopathy, and cardiomyopathy.
Collapse
Affiliation(s)
- Woong Bi Jang
- Laboratory for Vascular Medicine and Stem Cell Biology, Department of Physiology, Medical Research Institute, School of Medicine, Pusan National University, Yangsan, 50612, Republic of Korea
- Convergence Stem Cell Research Center, Pusan National University, Yangsan, 50612, Republic of Korea
| | - Dongwon Yi
- Division of Endocrinology and Metabolism, Department of Internal Medicine, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, 50612, Republic of Korea
| | - Thanh Mien Nguyen
- Bio-IT Fusion Technology Research Institute, Pusan National University, Busan, 46241, Republic of Korea
| | - Yujin Lee
- Department of Nano Fusion Technology, Pusan National University, Busan, 46214, Republic of Korea
| | - Eun Ji Lee
- Laboratory for Vascular Medicine and Stem Cell Biology, Department of Physiology, Medical Research Institute, School of Medicine, Pusan National University, Yangsan, 50612, Republic of Korea
- Convergence Stem Cell Research Center, Pusan National University, Yangsan, 50612, Republic of Korea
| | - Jaewoo Choi
- Laboratory for Vascular Medicine and Stem Cell Biology, Department of Physiology, Medical Research Institute, School of Medicine, Pusan National University, Yangsan, 50612, Republic of Korea
- Convergence Stem Cell Research Center, Pusan National University, Yangsan, 50612, Republic of Korea
| | - You Hwan Kim
- Department of Nano Fusion Technology, Pusan National University, Busan, 46214, Republic of Korea
| | - Eun-Jung Choi
- Department of Nano Fusion Technology, Pusan National University, Busan, 46214, Republic of Korea
| | - Jin-Woo Oh
- Bio-IT Fusion Technology Research Institute, Pusan National University, Busan, 46241, Republic of Korea
- Department of Nano Fusion Technology, Pusan National University, Busan, 46214, Republic of Korea
- Korea Nanobiotechnology Center, Pusan National University, Busan, 46241, Republic of Korea
| | - Sang-Mo Kwon
- Laboratory for Vascular Medicine and Stem Cell Biology, Department of Physiology, Medical Research Institute, School of Medicine, Pusan National University, Yangsan, 50612, Republic of Korea
- Convergence Stem Cell Research Center, Pusan National University, Yangsan, 50612, Republic of Korea
| |
Collapse
|
27
|
Swargiary K, Jitpratak P, Pathak AK, Viphavakit C. Low-Cost ZnO Spray-Coated Optical Fiber Sensor for Detecting VOC Biomarkers of Diabetes. SENSORS (BASEL, SWITZERLAND) 2023; 23:7916. [PMID: 37765971 PMCID: PMC10536205 DOI: 10.3390/s23187916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 09/09/2023] [Accepted: 09/14/2023] [Indexed: 09/29/2023]
Abstract
A non-invasive optical fiber sensor for detecting volatile organic compounds (VOCs) as biomarkers of diabetes is proposed and experimentally demonstrated. It offers a low-cost and straightforward fabrication approach by implementing a one-step spray coating of a ZnO colloidal solution on a glass optical fiber. The structure of the optical fiber sensor is based on a single-mode fiber-coreless silica fiber-single-mode fiber (SMF-CSF-SMF) structure, where the CSF is the sensor region spliced between two SMFs. The ZnO layer of a higher refractive index coated over the sensing region improves the light interaction with the surrounding medium, leading to sensitivity enhancement. The optical properties, morphology, and elemental composition of the ZnO layer were analyzed. The sensing mechanism of the developed sensor is based on a wavelength interrogation technique showing wavelength shifts when the sensor is exposed to various VOC vapor concentration levels. Various concentrations of the three VOCs (including acetone, isopropanol, and ethanol) ranging from 20% to 100% were tested and analyzed. The sensor noticeably shows a significant response towards acetone vapor, with a better sensitivity of 0.162 nm/% vapor than for isopropanol (0.082 nm/% vapor) and ethanol (0.075 nm/% vapor) vapors. The high sensitivity and selectivity towards acetone, a common biomarker for diabetes, offers the potential for further development of this sensor as a smart healthcare system for monitoring diabetic conditions.
Collapse
Affiliation(s)
- Kankan Swargiary
- International School of Engineering (ISE), Intelligent Control Automation of Process Systems Research Unit, Chulalongkorn University, Bangkok 10330, Thailand
| | - Pannathorn Jitpratak
- Biomedical Engineering Program, Faculty of Engineering, Chulalongkorn University, Bangkok 10330, Thailand
| | - Akhilesh Kumar Pathak
- Center for Smart Structures and Materials, Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Charusluk Viphavakit
- International School of Engineering (ISE), Intelligent Control Automation of Process Systems Research Unit, Chulalongkorn University, Bangkok 10330, Thailand
| |
Collapse
|
28
|
Bratu AM, Bojan M, Banita S, Petrus M, Popa C. NIR and THz spectroscopy: An experimental investigation toward nicotine-related devices. JOURNAL OF BIOPHOTONICS 2023; 16:e202300120. [PMID: 37260323 DOI: 10.1002/jbio.202300120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 05/15/2023] [Accepted: 05/24/2023] [Indexed: 06/02/2023]
Abstract
This study examined the content of nicotine-delivery products using terahertz time-domain spectroscopy (THz-TDS) and breath ethylene investigated with CO2 laser photoacoustic spectroscopy (CO2 LPAS) system as a biomarker of oxidative stress after smoking. The THz-TDS method provided valuable information on the transmission spectra of tobacco and nicotine in smoking products. From the CO2 LPAS data it was observed that in cigarette (TC) smoking the mean breath ethylene was 687 parts per billion (ppb), while in electronic cigarettes and tobacco heating devices smoking the mean ethylene was 56 ppb and 48 ppb, respectively. The main finding was that TC showed higher transmission in the THz region producing a higher oxidative stress on the body.
Collapse
Affiliation(s)
- Ana-Maria Bratu
- National Institute for Laser, Plasma and Radiation Physics, Bucharest, PO, Romania
| | - Mihaela Bojan
- National Institute for Laser, Plasma and Radiation Physics, Bucharest, PO, Romania
| | - Stefan Banita
- National Institute for Laser, Plasma and Radiation Physics, Bucharest, PO, Romania
| | - Mioara Petrus
- National Institute for Laser, Plasma and Radiation Physics, Bucharest, PO, Romania
| | - Cristina Popa
- National Institute for Laser, Plasma and Radiation Physics, Bucharest, PO, Romania
| |
Collapse
|
29
|
Lagopati N, Valamvanos TF, Proutsou V, Karachalios K, Pippa N, Gatou MA, Vagena IA, Cela S, Pavlatou EA, Gazouli M, Efstathopoulos E. The Role of Nano-Sensors in Breath Analysis for Early and Non-Invasive Disease Diagnosis. CHEMOSENSORS 2023; 11:317. [DOI: 10.3390/chemosensors11060317] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/11/2023]
Abstract
Early-stage, precise disease diagnosis and treatment has been a crucial topic of scientific discussion since time immemorial. When these factors are combined with experience and scientific knowledge, they can benefit not only the patient, but also, by extension, the entire health system. The development of rapidly growing novel technologies allows for accurate diagnosis and treatment of disease. Nanomedicine can contribute to exhaled breath analysis (EBA) for disease diagnosis, providing nanomaterials and improving sensing performance and detection sensitivity. Through EBA, gas-based nano-sensors might be applied for the detection of various essential diseases, since some of their metabolic products are detectable and measurable in the exhaled breath. The design and development of innovative nanomaterial-based sensor devices for the detection of specific biomarkers in breath samples has emerged as a promising research field for the non-invasive accurate diagnosis of several diseases. EBA would be an inexpensive and widely available commercial tool that could also be used as a disease self-test kit. Thus, it could guide patients to the proper specialty, bypassing those expensive tests, resulting, hence, in earlier diagnosis, treatment, and thus a better quality of life. In this review, some of the most prevalent types of sensors used in breath-sample analysis are presented in parallel with the common diseases that might be diagnosed through EBA, highlighting the impact of incorporating new technological achievements in the clinical routine.
Collapse
Affiliation(s)
- Nefeli Lagopati
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
- Biomedical Research Foundation, Academy of Athens, 11527 Athens, Greece
| | - Theodoros-Filippos Valamvanos
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
- Medical Physics Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, 12462 Athens, Greece
| | - Vaia Proutsou
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
- Medical Physics Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, 12462 Athens, Greece
| | - Konstantinos Karachalios
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
- Medical Physics Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, 12462 Athens, Greece
| | - Natassa Pippa
- Section of Pharmaceutical Technology, Department of Pharmacy, School of Health Sciences, National and Kapodistrian University of Athens, 15771 Athens, Greece
| | - Maria-Anna Gatou
- Laboratory of General Chemistry, School of Chemical Engineering, National Technical University of Athens, Zografou Campus, 15772 Athens, Greece
| | - Ioanna-Aglaia Vagena
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
| | - Smaragda Cela
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
- Medical Physics Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, 12462 Athens, Greece
| | - Evangelia A. Pavlatou
- Laboratory of General Chemistry, School of Chemical Engineering, National Technical University of Athens, Zografou Campus, 15772 Athens, Greece
| | - Maria Gazouli
- Laboratory of Biology, Department of Basic Medical Sciences, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
- School of Science and Technology, Hellenic Open University, 26335 Patra, Greece
| | - Efstathios Efstathopoulos
- Biomedical Research Foundation, Academy of Athens, 11527 Athens, Greece
- School of Science and Technology, Hellenic Open University, 26335 Patra, Greece
| |
Collapse
|
30
|
Alkhuder K. Fourier-transform infrared spectroscopy: a universal optical sensing technique with auspicious application prospects in the diagnosis and management of autoimmune diseases. Photodiagnosis Photodyn Ther 2023; 42:103606. [PMID: 37187270 DOI: 10.1016/j.pdpdt.2023.103606] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 04/27/2023] [Accepted: 05/09/2023] [Indexed: 05/17/2023]
Abstract
Autoimmune diseases (AIDs) are poorly understood clinical syndromes due to breakdown of immune tolerance towards specific types of self-antigens. They are generally associated with an inflammatory response mediated by lymphocytes T, autoantibodies or both. Ultimately, chronic inflammation culminates in tissue damages and clinical manifestations. AIDs affect 5% of the world population, and they represent the main cause of fatality in young to middle-aged females. In addition, the chronic nature of AIDs has a devastating impact on the patient's quality of life. It also places a heavy burden on the health care system. Establishing a rapid and accurate diagnosis is considered vital for an ideal medical management of these autoimmune disorders. However, for some AIDs, this task might be challenging. Vibrational spectroscopies, and more particularly Fourier-transform infrared (FTIR) spectroscopy, have emerged as universal analytical techniques with promising applications in the diagnosis of various types of malignancies and metabolic and infectious diseases. The high sensitivity of these optical sensing techniques and their minimal requirements for test reagents qualify them to be ideal analytical techniques. The aim of the current review is to explore the potential applications of FTIR spectroscopy in the diagnosis and management of most common AIDs. It also aims to demonstrate how this technique has contributed to deciphering the biochemical and physiopathological aspects of these chronic inflammatory diseases. The advantages that can be offered by this optical sensing technique over the traditional and gold standard methods used in the diagnosis of these autoimmune disorders have also been extensively discussed.
Collapse
|
31
|
Orasugh JT, Saasa V, Ray SS, Mwakikunga B. Supersensitive metal free in-situ synthesized graphene oxide@cellulose nanocrystals acetone sensitive bioderived sensors. Int J Biol Macromol 2023; 241:124514. [PMID: 37086769 DOI: 10.1016/j.ijbiomac.2023.124514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 03/31/2023] [Accepted: 04/15/2023] [Indexed: 04/24/2023]
Abstract
A series of graphene oxide@cellulose nanocrystal (GO@CNC) nanoparticles (NPs) were synthesized in this study using a room temperature-based simple modified hummers process. The morphological structures, as well as chemical characteristics of these materials were characterized using, transmission electron microscopy (TEM), X-ray diffraction (XRD), and other techniques. The results show that the as-prepared nanoparticles are made up of crystallite grains with an average size of around 7.82, 14.69, 10.77, 7.82, and 12.51 nm for GO, CNC, GO1@CNC1, GO2@CNC3, and GO3@CNC3 respectively, and OH &COOH functionalities on the NPs' surfaces. GO@CNC NPs exhibit significantly better sensing characteristics towards acetone when compared to virgin GO nanoplatelets; specifically, the optimal sensor based on GO3@CNC3 NPs showed the highest response (60.88 at 5 ppm), which was higher than that of the virgin GO sensor at 200 °C operating temperature and including those reported. Furthermore, the sensors have a high sensitivity towards acetone in sub-ppm concentrations as well as a detection limit of 5 ppm, making it a viable candidate for diabetes breath testing.
Collapse
Affiliation(s)
- Jonathan Tersur Orasugh
- Department of Chemical Sciences, University of Johannesburg, Doorfontein, Johannesburg 2028, South Africa; Centre for Nanostructures and Advanced Materials, DSI-CSIR Nanotechnology Innovation Centre, Council for Scientific and Industrial Research, Pretoria 0001, South Africa.
| | - Valentine Saasa
- Centre for Nanostructures and Advanced Materials, DSI-CSIR Nanotechnology Innovation Centre, Council for Scientific and Industrial Research, Pretoria 0001, South Africa
| | - Suprakas Sinha Ray
- Department of Chemical Sciences, University of Johannesburg, Doorfontein, Johannesburg 2028, South Africa; Centre for Nanostructures and Advanced Materials, DSI-CSIR Nanotechnology Innovation Centre, Council for Scientific and Industrial Research, Pretoria 0001, South Africa.
| | - Bonex Mwakikunga
- Centre for Nanostructures and Advanced Materials, DSI-CSIR Nanotechnology Innovation Centre, Council for Scientific and Industrial Research, Pretoria 0001, South Africa; Department of Physics, Arcadia Campus, Tshwane University of Technology, Pretoria 0001, South Africa
| |
Collapse
|
32
|
Davis D, Narayanan SK, Ajeev A, Nair J, Jeeji J, Vijayan A, Viyyur Kuttyadi M, Nelliparambil Sathian A, Arulraj AK. Flexible Paper-Based Room-Temperature Acetone Sensors with Ultrafast Regeneration. ACS APPLIED MATERIALS & INTERFACES 2023. [PMID: 37075219 DOI: 10.1021/acsami.2c21712] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Paper-based lightweight, degradable, low-cost, and eco-friendly substrates are extensively used in wearable biosensor applications, albeit to a lesser extent in sensing acetone and other gas-phase analytes. Generally, rigid substrates with heaters have been employed to develop acetone sensors due to the high operating/recovery temperature (typically above 200 °C), limiting the use of papers as substrates in such sensing applications. In this work, we proposed fabricating the paper-based, room-temperature-operatable acetone sensor using ZnO-polyaniline-based acetone-sensing inks by a facile fabrication method. The fabricated paper-based electrodes showed good electrical conductivity (80 S/m) and mechanical stability (∼1000 bending cycles). The acetone sensors showed a sensitivity of 0.02/100 ppm and 0.6/10 μL with an ultrafast response (4 s) and recovery time (15 s) at room temperature. The sensors delivered a broad sensitivity over a physiological range of 260 to >1000 ppm with R2 > 0.98 under atmospheric conditions. Further, the role of the surface, interfacial, microstructure, electrical, and electromechanical properties of the paper-based sensor devices has been correlated with the sensitivity and room-temperature recovery observed in our system. These versatile, green, flexible electronic devices would be ideal for low-cost, highly regenerative, room-/low-temperature-operable wearable sensor applications.
Collapse
Affiliation(s)
- Disiya Davis
- Centre for Materials for Electronics Technology (C-MET), Shornur Road, Athani, MG Kavu Post, Thrissur 680581, Kerala, India
| | - Swathi Krishna Narayanan
- Centre for Materials for Electronics Technology (C-MET), Shornur Road, Athani, MG Kavu Post, Thrissur 680581, Kerala, India
| | - Arya Ajeev
- Centre for Materials for Electronics Technology (C-MET), Shornur Road, Athani, MG Kavu Post, Thrissur 680581, Kerala, India
| | - Jayashree Nair
- Centre for Materials for Electronics Technology (C-MET), Shornur Road, Athani, MG Kavu Post, Thrissur 680581, Kerala, India
| | - Jithin Jeeji
- Centre for Materials for Electronics Technology (C-MET), Shornur Road, Athani, MG Kavu Post, Thrissur 680581, Kerala, India
| | - Ananthu Vijayan
- Centre for Materials for Electronics Technology (C-MET), Shornur Road, Athani, MG Kavu Post, Thrissur 680581, Kerala, India
| | - Midhun Viyyur Kuttyadi
- Centre for Materials for Electronics Technology (C-MET), Shornur Road, Athani, MG Kavu Post, Thrissur 680581, Kerala, India
| | - Arun Nelliparambil Sathian
- Centre for Materials for Electronics Technology (C-MET), Shornur Road, Athani, MG Kavu Post, Thrissur 680581, Kerala, India
| | - Arul Kashmir Arulraj
- Centre for Materials for Electronics Technology (C-MET), Shornur Road, Athani, MG Kavu Post, Thrissur 680581, Kerala, India
| |
Collapse
|
33
|
Maiti KS. Non-Invasive Disease Specific Biomarker Detection Using Infrared Spectroscopy: A Review. Molecules 2023; 28:2320. [PMID: 36903576 PMCID: PMC10005715 DOI: 10.3390/molecules28052320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 02/22/2023] [Accepted: 02/22/2023] [Indexed: 03/06/2023] Open
Abstract
Many life-threatening diseases remain obscure in their early disease stages. Symptoms appear only at the advanced stage when the survival rate is poor. A non-invasive diagnostic tool may be able to identify disease even at the asymptotic stage and save lives. Volatile metabolites-based diagnostics hold a lot of promise to fulfil this demand. Many experimental techniques are being developed to establish a reliable non-invasive diagnostic tool; however, none of them are yet able to fulfil clinicians' demands. Infrared spectroscopy-based gaseous biofluid analysis demonstrated promising results to fulfil clinicians' expectations. The recent development of the standard operating procedure (SOP), sample measurement, and data analysis techniques for infrared spectroscopy are summarized in this review article. It has also outlined the applicability of infrared spectroscopy to identify the specific biomarkers for diseases such as diabetes, acute gastritis caused by bacterial infection, cerebral palsy, and prostate cancer.
Collapse
Affiliation(s)
- Kiran Sankar Maiti
- Max–Planck–Institut für Quantenoptik, Hans-Kopfermann-Straße 1, 85748 Garching, Germany; ; Tel.: +49-289-14054
- Lehrstuhl für Experimental Physik, Ludwig-Maximilians-Universität München, Am Coulombwall 1, 85748 Garching, Germany
- Laser-Forschungslabor, Klinikum der Universität München, Fraunhoferstrasse 20, 82152 Planegg, Germany
| |
Collapse
|
34
|
Gladding PA, Cooper M, Young R, Loader S, Smith K, Zarate E, Green S, Villas Boas SG, Shepherd P, Kakadiya P, Thorstensen E, Keven C, Coe M, Jüllig M, Zhang E, Schlegel TT. Metabolomics and a Breath Sensor Identify Acetone as a Biomarker for Heart Failure. Biomolecules 2022; 13:biom13010013. [PMID: 36671398 PMCID: PMC9856097 DOI: 10.3390/biom13010013] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 12/13/2022] [Accepted: 12/13/2022] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Multi-omics delivers more biological insight than targeted investigations. We applied multi-omics to patients with heart failure with reduced ejection fraction (HFrEF). METHODS 46 patients with HFrEF and 20 controls underwent metabolomic profiling, including liquid/gas chromatography mass spectrometry (LC-MS/GC-MS) and solid-phase microextraction (SPME) volatilomics in plasma and urine. HFrEF was defined using left ventricular global longitudinal strain, ejection fraction and NTproBNP. A consumer breath acetone (BrACE) sensor validated results in n = 73. RESULTS 28 metabolites were identified by GCMS, 35 by LCMS and 4 volatiles by SPME in plasma and urine. Alanine, aspartate and glutamate, citric acid cycle, arginine biosynthesis, glyoxylate and dicarboxylate metabolism were altered in HFrEF. Plasma acetone correlated with NT-proBNP (r = 0.59, 95% CI 0.4 to 0.7), 2-oxovaleric and cis-aconitic acid, involved with ketone metabolism and mitochondrial energetics. BrACE > 1.5 ppm discriminated HF from other cardiac pathology (AUC 0.8, 95% CI 0.61 to 0.92, p < 0.0001). CONCLUSION Breath acetone discriminated HFrEF from other cardiac pathology using a consumer sensor, but was not cardiac specific.
Collapse
Affiliation(s)
- Patrick A. Gladding
- Cardiology Department, Waitemata District Health Board, Auckland 0620, New Zealand; (M.C.); (R.Y.); (S.L.)
- Auckland Bioengineering Institute, Auckland 1142, New Zealand
- Correspondence:
| | - Maxine Cooper
- Cardiology Department, Waitemata District Health Board, Auckland 0620, New Zealand; (M.C.); (R.Y.); (S.L.)
| | - Renee Young
- Cardiology Department, Waitemata District Health Board, Auckland 0620, New Zealand; (M.C.); (R.Y.); (S.L.)
| | - Suzanne Loader
- Cardiology Department, Waitemata District Health Board, Auckland 0620, New Zealand; (M.C.); (R.Y.); (S.L.)
| | - Kevin Smith
- Clinical Laboratory, Waitemata District Health Board, Auckland 0622, New Zealand;
| | - Erica Zarate
- School of Biological Science, University of Auckland, Auckland 1010, New Zealand; (E.Z.); (S.G.); (S.G.V.B.)
| | - Saras Green
- School of Biological Science, University of Auckland, Auckland 1010, New Zealand; (E.Z.); (S.G.); (S.G.V.B.)
| | - Silas G. Villas Boas
- School of Biological Science, University of Auckland, Auckland 1010, New Zealand; (E.Z.); (S.G.); (S.G.V.B.)
| | - Phillip Shepherd
- Grafton Genomics Ltd., Liggins Institute, University of Auckland, Auckland 1010, New Zealand; (P.S.); (P.K.)
| | - Purvi Kakadiya
- Grafton Genomics Ltd., Liggins Institute, University of Auckland, Auckland 1010, New Zealand; (P.S.); (P.K.)
| | - Eric Thorstensen
- Liggins Institute, University of Auckland, Auckland 1010, New Zealand; (E.T.); (C.K.); (M.C.)
| | - Christine Keven
- Liggins Institute, University of Auckland, Auckland 1010, New Zealand; (E.T.); (C.K.); (M.C.)
| | - Margaret Coe
- Liggins Institute, University of Auckland, Auckland 1010, New Zealand; (E.T.); (C.K.); (M.C.)
| | - Mia Jüllig
- Paper Dog Ltd., Waiheke Island, Auckland 1081, New Zealand;
| | - Edmond Zhang
- Precision Driven Health Initiative, Auckland 1021, New Zealand;
| | - Todd T. Schlegel
- Karolinska Institutet, 17177 Stockholm, Sweden;
- Nicollier-Schlegel Sàrl, 1270 Trélex, Switzerland
| |
Collapse
|
35
|
Mao X, Ji X, Tan Y, Ye H, Wang X. High-sensitivity all-optical PA spectrometer based on fast swept laser interferometry. PHOTOACOUSTICS 2022; 28:100391. [PMID: 36042699 PMCID: PMC9420372 DOI: 10.1016/j.pacs.2022.100391] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/29/2022] [Revised: 08/11/2022] [Accepted: 08/15/2022] [Indexed: 06/15/2023]
Abstract
A high-sensitivity all-optical photoacoustic spectroscopy based on fast swept laser interferometry is proposed to trace gas detection. The momentary cavity length of the fiber-optic Fabry-Perot microphone is demodulated by a fast swept-laser interferometry with an instantaneous frequency demodulation algorithm. The all-optical photoacoustic spectroscopy based on the designed microphone was tested for trace acetylene gas detection in the near-infrared region. The normalized noise equivalent absorption coefficient for acetylene gas is achieved to be 1.06 × 10-9 cm-1 W Hz-1∕2.
Collapse
|
36
|
Sensing properties of acetone gas on the two-dimensional orthorhombic diboron dinitride sheet: A DFT Investigation. COMPUT THEOR CHEM 2022. [DOI: 10.1016/j.comptc.2022.113935] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
37
|
Asad M, Muhammad N, Khan N, Shah M, Khan M, Khan M, Badshah A, Latif Z, Nishan U. Colorimetric acetone sensor based on ionic liquid functionalized drug-mediated silver nanostructures. J Pharm Biomed Anal 2022; 221:115043. [PMID: 36155483 DOI: 10.1016/j.jpba.2022.115043] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 09/08/2022] [Accepted: 09/10/2022] [Indexed: 11/25/2022]
Abstract
The current work reports the drug-mediated synthesis of silver nanoparticles (AgNPs) and their functionalization with ionic liquid (IL) for acetone determination. The rationale behind the selection of the Augmentin drug was the aromaticity in its structure and the functional groups attached. These properties are not only supposed to work in the synthesis of the nanoparticles but also enhance their electron density. The nanoparticles were further coated with 1-H-3-methylimidazolium acetate IL, having conductivity and aromaticity in their structure. The synthesized nanoparticles have been characterized by different techniques such as FTIR, XRD, SEM, and EDX. Colorimetric determination of acetone was done by using IL capped AgNPs with the assistance of NaCl solution and results were analyzed by UV-Vis spectrophotometry. Low-cost, stable eosin dye works as a substrate and is consumed resulting in a color change from brown to transparent. The IL capped AgNPs act as a reducing agent for the production of reduced radical form of acetone which act on the carboxylate moiety and bubble it out in the form of CO2. Different parameters such as (concentrations, loading of nanoparticles, time and pH, etc.) were optimized to get the best results of the proposed sensor. The sensor shows a wide linear range of (1 ×10-8-2.40 ×10-6 M), low limit of detection 2.66 × 10-9 M, and limit of quantification 8.86 × 10-9 M with an R2 value of 0.997. The proposed sensor has been successfully applied to diabetic patient's urine samples for acetone detection with a visible colorimetric change. It showed good sensitivity and selectivity towards acetone detection.
Collapse
Affiliation(s)
- Muhammad Asad
- Department of Chemistry, Kohat University of Science and Technology, Kohat 26000, KP, Pakistan
| | - Nawshad Muhammad
- Department of Dental Materials, Institute of Basic Medical Sciences Khyber Medical University, Peshawar, KP, Pakistan
| | - Naeem Khan
- Department of Chemistry, Kohat University of Science and Technology, Kohat 26000, KP, Pakistan
| | - Mohibullah Shah
- Department of Biochemistry, Bahauddin Zakariya University, Multan 66000, Pakistan.
| | - Muslim Khan
- Department of Chemistry, Kohat University of Science and Technology, Kohat 26000, KP, Pakistan
| | - Mansoor Khan
- Department of Chemistry, Kohat University of Science and Technology, Kohat 26000, KP, Pakistan
| | - Amir Badshah
- Department of Chemistry, Kohat University of Science and Technology, Kohat 26000, KP, Pakistan
| | - Zahina Latif
- Regional Blood Center Hayatabad, Peshawar, KP, Pakistan
| | - Umar Nishan
- Department of Chemistry, Kohat University of Science and Technology, Kohat 26000, KP, Pakistan.
| |
Collapse
|
38
|
A user preference analysis of commercial breath ketone sensors to inform the development of portable breath ketone sensors for diabetes management in young people. PLoS One 2022; 17:e0269925. [PMID: 35877679 PMCID: PMC9312428 DOI: 10.1371/journal.pone.0269925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Accepted: 05/31/2022] [Indexed: 11/25/2022] Open
Abstract
Background Portable breath ketone sensors may help people with Type 1 Diabetes Mellitus (T1DM) avoid episodes of diabetic ketoacidosis; however, the design features preferred by users have not been studied. We aimed to elucidate breath sensor design preferences of young people with T1DM (age 12 to 16) and their parents to inform the development of a breath ketone sensor prototype that would best suit their diabetes management needs. Research designs and methods To elicit foundational experiences from which design preference ideas could be generated, two commercially available breath ketone sensors, designed for ketogenic diet monitoring, were explored over one week by ten young people with T1DM. Participants interacted with the breath ketone sensing devices, and undertook blood ketone testing, at least twice daily for five days to simulate use within a real life and ambulatory care setting. Semi-structured interviews were conducted post-testing with the ten young participants and their caregivers (n = 10) to elicit preferences related to breath sensor design and use, and to inform the co-design of a breath ketone sensor prototype for use in T1DM self-management. We triangulated our data collection with key informant interviews with two diabetes educators working in pediatric care about their perspectives related to young people using breath ketone sensors. Results Participants acknowledged the non-invasiveness of breath sensors as compared to blood testing. Affordability, reliability and accuracy were identified as prerequisites for breath ketone sensors used for diabetes management. Design features valued by young people included portability, ease of use, sustainability, readability and suitability for use in public. The time required to use breath sensors was similar to that for blood testing. The requirement to maintain a 10-second breath exhalation posed a challenge for users. Diabetes educators highlighted the ease of use of breath devices especially for young people who tended to under-test using blood ketone strips. Conclusions Breath ketone sensors for diabetes management have potential that may facilitate ketone testing in young people. Our study affirms features for young people that drive usability of breath sensors among this population, and provides a model of user preference assessment.
Collapse
|
39
|
Obeidat Y, Rawashdeh AM, Hammoudeh A, Al-Assi R, Dagamseh A, Qananwah Q. Acetone sensing in liquid and gas phases using cyclic voltammetry. Sci Rep 2022; 12:11010. [PMID: 35773395 PMCID: PMC9247076 DOI: 10.1038/s41598-022-15135-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Accepted: 06/20/2022] [Indexed: 02/02/2023] Open
Abstract
This paper presents the use of cyclic voltammetry to measure acetone concentration in liquid and vapor forms at disposable screen-printed electrodes of platinum working electrode, platinum counter electrode, and silver/silver chloride reference electrode. The main characteristics of the acetone sensor including its linearity, sensitivity, reproducibility, and limit of detection (LOD) were studied by doing different experiments to test both liquid and vapor samples in the physiological range of 1 µM to 10 mM. The change in acetone concentration was monitored by comparing the lineshape of butterfly region before and after injecting the acetone sample in the baseline solution that contains 0.5 M H2SO4. The sensor was shown to have a good sensitivity, reproducibility, and a linear response with respect to the acetone concentration in both liquid and gas phases over a range of 1 µM to 10 mM with R2 > 0.97 and LOD of 0.1 µM. The system stability was improved by building a closed glass system to reduce the exchange of acetone with the surrounding air in an open environment. The closed system was tested using vapor samples and the error bars in the calibration curve were reduced to more than half of their values before using the closed system. The new system will be used extensively in future for an enzyme-based acetone sensor that will be used for diabetes monitoring.
Collapse
Affiliation(s)
- Yusra Obeidat
- grid.14440.350000 0004 0622 5497Electronic Engineering Department, Hijjawi Faculty for Engineering Technology, Yarmouk University, Irbid, 21163 Jordan
| | - Abdel Monem Rawashdeh
- grid.14440.350000 0004 0622 5497Department of Chemistry, Faculty of Sciences, Yarmouk University, P.O. Box 566, Irbid, Jordan
| | - Ayman Hammoudeh
- grid.14440.350000 0004 0622 5497Department of Chemistry, Faculty of Sciences, Yarmouk University, P.O. Box 566, Irbid, Jordan
| | - Rawan Al-Assi
- grid.14440.350000 0004 0622 5497Department of Biomedical Systems and Informatics Engineering, Hijjawi Faculty for Engineering Technology, Yarmouk University, Irbid, 21163 Jordan
| | - Ahmad Dagamseh
- grid.14440.350000 0004 0622 5497Electronic Engineering Department, Hijjawi Faculty for Engineering Technology, Yarmouk University, Irbid, 21163 Jordan
| | - Qasem Qananwah
- grid.14440.350000 0004 0622 5497Department of Biomedical Systems and Informatics Engineering, Hijjawi Faculty for Engineering Technology, Yarmouk University, Irbid, 21163 Jordan
| |
Collapse
|
40
|
Lee P, Kim H, Kim Y, Choi W, Zitouni MS, Khandoker A, Jelinek HF, Hadjileontiadis L, Lee U, Jeong Y. Beyond Pathogen Filtration: Possibility of Smart Masks as Wearable Devices for Personal and Group Health and Safety Management. JMIR Mhealth Uhealth 2022; 10:e38614. [PMID: 35679029 PMCID: PMC9217147 DOI: 10.2196/38614] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2022] [Revised: 05/20/2022] [Accepted: 06/08/2022] [Indexed: 12/15/2022] Open
Abstract
Face masks are an important way to combat the COVID-19 pandemic. However, the prolonged pandemic has revealed confounding problems with the current face masks, including not only the spread of the disease but also concurrent psychological, social, and economic complications. As face masks have been worn for a long time, people have been interested in expanding the purpose of masks from protection to comfort and health, leading to the release of various "smart" mask products around the world. To envision how the smart masks will be extended, this paper reviewed 25 smart masks (12 from commercial products and 13 from academic prototypes) that emerged after the pandemic. While most smart masks presented in the market focus on resolving problems with user breathing discomfort, which arise from prolonged use, academic prototypes were designed for not only sensing COVID-19 but also general health monitoring aspects. Further, we investigated several specific sensors that can be incorporated into the mask for expanding biophysical features. On a larger scale, we discussed the architecture and possible applications with the help of connected smart masks. Namely, beyond a personal sensing application, a group or community sensing application may share an aggregate version of information with the broader population. In addition, this kind of collaborative sensing will also address the challenges of individual sensing, such as reliability and coverage. Lastly, we identified possible service application fields and further considerations for actual use. Along with daily-life health monitoring, smart masks may function as a general respiratory health tool for sports training, in an emergency room or ambulatory setting, as protection for industry workers and firefighters, and for soldier safety and survivability. For further considerations, we investigated design aspects in terms of sensor reliability and reproducibility, ergonomic design for user acceptance, and privacy-aware data-handling. Overall, we aim to explore new possibilities by examining the latest research, sensor technologies, and application platform perspectives for smart masks as one of the promising wearable devices. By integrating biomarkers of respiration symptoms, a smart mask can be a truly cutting-edge device that expands further knowledge on health monitoring to reach the next level of wearables.
Collapse
Affiliation(s)
- Peter Lee
- KAIST Institute for Health Science and Technology, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Heepyung Kim
- KAIST Institute for Health Science and Technology, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Yongshin Kim
- Graduate School of Data Science, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Woohyeok Choi
- Information & Electronics Research Institute, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - M Sami Zitouni
- Department of Biomedical Engineering, Khalifa University of Science and Technology, Abu Dhabi, United Arab Emirates
- Healthcare Engineering Innovation Center, Khalifa University of Science and Technology, Abu Dhabi, United Arab Emirates
| | - Ahsan Khandoker
- Department of Biomedical Engineering, Khalifa University of Science and Technology, Abu Dhabi, United Arab Emirates
- Healthcare Engineering Innovation Center, Khalifa University of Science and Technology, Abu Dhabi, United Arab Emirates
| | - Herbert F Jelinek
- Department of Biomedical Engineering, Khalifa University of Science and Technology, Abu Dhabi, United Arab Emirates
- Healthcare Engineering Innovation Center, Khalifa University of Science and Technology, Abu Dhabi, United Arab Emirates
| | - Leontios Hadjileontiadis
- Department of Biomedical Engineering, Khalifa University of Science and Technology, Abu Dhabi, United Arab Emirates
- Healthcare Engineering Innovation Center, Khalifa University of Science and Technology, Abu Dhabi, United Arab Emirates
- Department of Electrical and Computer Engineering, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Uichin Lee
- KAIST Institute for Health Science and Technology, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
- School of Computing, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Yong Jeong
- KAIST Institute for Health Science and Technology, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| |
Collapse
|
41
|
Bio-Alcohol Sensor Based on One-Dimensional Photonic Crystals for Detection of Organic Materials in Wastewater. MATERIALS 2022; 15:ma15114012. [PMID: 35683310 PMCID: PMC9182233 DOI: 10.3390/ma15114012] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 04/16/2022] [Accepted: 05/09/2022] [Indexed: 11/17/2022]
Abstract
In this work, we have explored a novel application of one–dimensional (1D) photonic crystals (PCs) as a biomarker for the detection of organic materials in wastewater. The high concentration of organic materials may lead to adverse impact on human life. In order to save human life from these adverse effects, we have investigated the bio-alcohol sensing properties of a 1D multilayer periodic structure (AB)N/C/(AB)N capable of detecting organic materials in wastewater. The proposed structure works on the principle to detect a very small change in the refractive index of the wastewater sample under investigation by means of producing a shift in the position of the defect mode inside the photonic band gap (PBG) of the proposed structure. The transfer matrix method (TMM) has been used to investigate the transmission properties of the proposed design with the help of MATLAB software. We have also studied the effect of changes in the defect layer’s thickness, the volume fraction of the nanocomposite material and the incident angle on the sensitivity of our proposed bio-alcohol sensing design. Our bio-alcohol sensor shows a high sensitivity value of 500 nm/RIU and a low detection limit value of 1 × 10−5 RIU. The figure of merit and quality factor values of our bio-alcohol sensor are 5 × 103 and 5.236 × 103, respectively. The damping rate of the design is ξ=95.4927×10−5.
Collapse
|
42
|
Mogharbel AT, Pashameah RA, Alluhaybi AA, Almahri A, Abumelha HM, Habeebullah TM, El-Metwaly NM. Development of a “Turn-off” fluorescent sensor for acetone from rice straw-derived carbon dots immobilized onto textile cotton mask. J Mol Liq 2022. [DOI: 10.1016/j.molliq.2022.119666] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
43
|
Rudie A, Schornack AM, Wu Q, Zhang Q, Wang D. Two-Dimensional Ti 3C 2 MXene-Based Novel Nanocomposites for Breath Sensors for Early Detection of Diabetes Mellitus. BIOSENSORS 2022; 12:332. [PMID: 35624633 PMCID: PMC9139044 DOI: 10.3390/bios12050332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 05/02/2022] [Accepted: 05/07/2022] [Indexed: 11/16/2022]
Abstract
The rates of diabetes throughout the world are rising rapidly, impacting nearly every country. New research is focused on better ways to monitor and treat this disease. Breath acetone levels have been defined as a biomarker for diabetes. The development of a method to monitor and diagnose diabetes utilizing breath acetone levels would provide a fast, easy, and non-invasive treatment option. An ideal material for point-of-care diabetes management would need to have a high response to acetone, high acetone selectivity, low interference from humidity, and be able to operate at room temperature. Chemiresistive gas sensors are a promising method for sensing breath acetone due to their simple fabrication and easy operation. Certain semiconductor materials in chemiresistive sensors can react to acetone in the air and produce changes in resistance that can be correlated with acetone levels. While these materials have been developed and show strong responses to acetone with good selectivity, most of them must operate at high temperatures (compared to RT), causing high power consumption, unstable device operation, and complex device design. In this paper, we systematically studied a series of 2-dimensional MXene-based nanocomposites as the sensing materials in chemiresistive sensors to detect 2.86 ppm of acetone at room temperature. Most of them showed great sensitivity and selectivity for acetone. In particular, the 1D/2D CrWO/Ti3C2 nanocomposite showed the best sensing response to acetone: nine times higher sensitivity than 1D KWO nanowires. To determine the sensing selectivity, a CrWO/Ti3C2 nanocomposite-based sensor was exposed to various common vapors in human breath. The result revealed that it has excellent selectivity for acetone, and far lower responses to other vapors. All these preliminary results indicate that this material is a promising candidate for the creation of a point-of-care diabetes management device.
Collapse
Affiliation(s)
- Anna Rudie
- Department of Electrical and Computer Engineering, North Dakota State University, Fargo, ND 58102, USA; (A.R.); (Q.Z.)
| | - Anna Marie Schornack
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55902, USA;
| | - Qiang Wu
- Department of Mathematics, Physics, and Electrical Engineering, Northumbria University, Newcastle NE1 8ST, UK;
| | - Qifeng Zhang
- Department of Electrical and Computer Engineering, North Dakota State University, Fargo, ND 58102, USA; (A.R.); (Q.Z.)
- Materials and Nanotechnology Program, North Dakota State University, Fargo, ND 58102, USA
| | - Danling Wang
- Department of Electrical and Computer Engineering, North Dakota State University, Fargo, ND 58102, USA; (A.R.); (Q.Z.)
- Materials and Nanotechnology Program, North Dakota State University, Fargo, ND 58102, USA
| |
Collapse
|
44
|
Fabrication of chemiresistive nanosensor using molecularly imprinted polymers for acetone detection in gaseous state. IRANIAN POLYMER JOURNAL 2022. [DOI: 10.1007/s13726-022-01044-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
45
|
Hee Cho C, Choe YS, Chae S, Il Lee T. Highly sensitive breath sensor based on sonochemically synthesized cobalt-doped zinc oxide spherical beads. ULTRASONICS SONOCHEMISTRY 2022; 84:105956. [PMID: 35190351 PMCID: PMC8861145 DOI: 10.1016/j.ultsonch.2022.105956] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Revised: 01/22/2022] [Accepted: 02/14/2022] [Indexed: 06/14/2023]
Abstract
In this study, we introduce cobalt (Co)-doped zinc oxide (ZnO) spherical beads (SBs), synthesized using a sonochemical process, and their utilization for an acetone sensor that can be applied to an exhalation diagnostic device. The sonochemically synthezied Co-doped ZnO SBs were polycrystalline phases with sizes of several hundred nanometers formed by the aggregation of ZnO nanocrystals. As the Co doping concentration increased, the amount of substitutionally doped Co2+ in the ZnO nanocrystals increased, and we observed that the fraction of Co3+ in the Co-doped ZnO SBs increased while the fraction of oxygen vacancies decreased. At an optimal Co-doping concentration of 2 wt%, the sensor operating temperature decreased from 300 to 250 °C, response to 1 ppm acetone improved from 3.3 to 7.9, and minimum acetone detection concentration was measured at 43 ppb (response, 1.75). These enhancements are attributed to the catalytic role of Co3+ in acetone oxidation. Finally, a sensor fabricated using 2 wt% Co-doped ZnO SBs was installed in a commercially available exhalation diagnostic device to successfully measure the concentration of acetone in 1 ml of exhaled air from a healthy adult, returning a value of 0.44 ppm.
Collapse
Affiliation(s)
- Chang Hee Cho
- Department of Materials Science and Engineering, Gachon University, Seong-nam, Gyeonggi 13120, Korea
| | - Yong-Sahm Choe
- iSenLab Inc. Dunchondae-ro 545, Jungwong-gu, Seong-nam, Gyeonggi, Korea
| | - Soosang Chae
- IPF - Leibniz-Institut für Polymerforschung Dresden e.V, Institute of Physical Chemistry and Polymer Physics, 01069 Dresden, Germany.
| | - Tae Il Lee
- Department of Materials Science and Engineering, Gachon University, Seong-nam, Gyeonggi 13120, Korea.
| |
Collapse
|
46
|
Sha M, Maurya MR, Shafath S, Cabibihan JJ, Al-Ali A, Malik RA, Sadasivuni KK. Breath Analysis for the In Vivo Detection of Diabetic Ketoacidosis. ACS OMEGA 2022; 7:4257-4266. [PMID: 35155918 PMCID: PMC8830064 DOI: 10.1021/acsomega.1c05948] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2021] [Accepted: 01/10/2022] [Indexed: 06/14/2023]
Abstract
Human breath analysis of volatile organic compounds has gained significant attention recently because of its rapid and noninvasive potential to detect various metabolic diseases. The detection of ketones in the breath and blood is key to diagnosing and managing diabetic ketoacidosis (DKA) in patients with type 1 diabetes. It may also be of increasing importance to detect euglycemic ketoacidosis in patients with type 1 or type 2 diabetes or heart failure, treated with sodium-glucose transporter-2 inhibitors (SGLT2-i). The present research evaluates the efficiency of colorimetry for detecting acetone and ethanol in exhaled human breath with the response time, pH effect, temperature effect, concentration effect, and selectivity of dyes. Using the proposed multidye system, we obtained a detection limit of 0.0217 ppm for acetone and 0.029 ppm for ethanol in the detection range of 0.05-50 ppm. A smartphone-assisted unit consisting of a portable colorimetric device was used to detect relative red/green/blue values within 60 s of the interface for practical and real-time application. The developed method could be used for rapid, low-cost detection of ketones in patients with type 1 diabetes and DKA and patients with type 1 or type 2 diabetes or heart failure treated with SGLT2-I and euglycemic ketoacidosis.
Collapse
Affiliation(s)
- Mizaj
Shabil Sha
- Center
for Advanced Materials, Qatar University, P.O. Box 2713, Doha 2713, Qatar
| | - Muni Raj Maurya
- Center
for Advanced Materials, Qatar University, P.O. Box 2713, Doha 2713, Qatar
- Department
of Mechanical and Industrial Engineering, Qatar University, P.O. Box 2713, Doha 2713, Qatar
| | - Sadiyah Shafath
- Center
for Advanced Materials, Qatar University, P.O. Box 2713, Doha 2713, Qatar
- Department
of Chemical Engineering, Qatar University, P.O. Box 2713, Doha 2713, Qatar
| | - John-John Cabibihan
- Department
of Mechanical and Industrial Engineering, Qatar University, P.O. Box 2713, Doha 2713, Qatar
| | - Abdulaziz Al-Ali
- Department
of Computer Science and Engineering, Qatar
University, P.O. Box 2713, Doha 2713, Qatar
- KINDI
Center for Computing Research, Qatar University, Doha 2713, Qatar
| | - Rayaz A. Malik
- Weill Cornell
Medicine-Qatar, Qatar Foundation-Education
City, P.O. Box 24144, Doha 2713, Qatar
| | | |
Collapse
|
47
|
Lan K, Wang Z, Yang X, Wei J, Qin Y, Qin G. Flexible silicon nanowires sensor for acetone detection on plastic substrates. NANOTECHNOLOGY 2022; 33:155502. [PMID: 34963109 DOI: 10.1088/1361-6528/ac46b3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2021] [Accepted: 12/27/2021] [Indexed: 06/14/2023]
Abstract
Acetone commonly exists in daily life and is harmful to human health, therefore the convenient and sensitive monitoring of acetone is highly desired. In addition, flexible sensors have the advantages of light-weight, conformal attachable to irregular shapes, etc. In this study, we fabricated high performance flexible silicon nanowires (SiNWs) sensor for acetone detection by transferring the monocrystalline Si film and metal-assisted chemical etching method on polyethylene terephthalate (PET). The SiNWs sensor enabled detection of gaseous acetone with a concentration as low as 0.1 parts per million (ppm) at flat and bending states. The flexible SiNWs sensor was compatible with the CMOS process and exhibited good sensitivity, selectivity and repeatability for acetone detection at room temperature. The flexible sensor showed performance improvement under mechanical bending condition and the underlying mechanism was discussed. The results demonstrated the good potential of the flexible SiNWs sensor for the applications of wearable devices in environmental safety, food quality, and healthcare.
Collapse
Affiliation(s)
- Kuibo Lan
- School of Microelectronics, Tianjin University, Tianjin 300072, People's Republic of China
- Tianjin Key Laboratory of Imaging and Sensing Microelectronic Technology, Tianjin University, Tianjin 300072, People's Republic of China
| | - Zhi Wang
- School of Microelectronics, Tianjin University, Tianjin 300072, People's Republic of China
| | - Xiaodong Yang
- School of Microelectronics, Tianjin University, Tianjin 300072, People's Republic of China
| | - Junqing Wei
- School of Microelectronics, Tianjin University, Tianjin 300072, People's Republic of China
| | - Yuxiang Qin
- School of Microelectronics, Tianjin University, Tianjin 300072, People's Republic of China
- Tianjin Key Laboratory of Imaging and Sensing Microelectronic Technology, Tianjin University, Tianjin 300072, People's Republic of China
| | - Guoxuan Qin
- School of Microelectronics, Tianjin University, Tianjin 300072, People's Republic of China
- Tianjin Key Laboratory of Imaging and Sensing Microelectronic Technology, Tianjin University, Tianjin 300072, People's Republic of China
| |
Collapse
|
48
|
di Nunzio MR, Gutiérrez M, Moreno JM, Corma A, Díaz U, Douhal A. Interrogating the Behaviour of a Styryl Dye Interacting with a Mesoscopic 2D-MOF and Its Luminescent Vapochromic Sensing. Int J Mol Sci 2021; 23:ijms23010330. [PMID: 35008756 PMCID: PMC8745538 DOI: 10.3390/ijms23010330] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 12/21/2021] [Accepted: 12/23/2021] [Indexed: 12/14/2022] Open
Abstract
In this contribution, we report on the solid-state-photodynamical properties and further applications of a low dimensional composite material composed by the luminescent trans-4-(dicyanomethylene)-2-methyl-6-(4-dimethylaminostyryl)-4H-pyran (DCM) dye interacting with a two-dimensional-metal organic framework (2D-MOF), Al-ITQ-HB. Three different samples with increasing concentration of DCM are synthesized and characterized. The broad UV-visible absorption spectra of the DCM/Al-ITQ-HB composites reflect the presence of different species of DCM molecules (monomers and aggregates). In contrast, the emission spectra are narrower and exhibit a bathochromic shift upon increasing the DCM concentration, in agreeance with the formation of adsorbed aggregates. Time-resolved picosecond (ps)-experiments reveal multi-exponential behaviors of the excited composites, further confirming the heterogeneous nature of the samples. Remarkably, DCM/Al-ITQ-HB fluorescence is sensitive to vapors of electron donor aromatic amine compounds like aniline, methylaniline, and benzylamine due to a H-bonding-induced electron transfer (ET) process from the analyte to the surface-adsorbed DCM. These findings bring new insights on the photobehavior of a well-known dye when interacting with a 2D-MOF and its possible application in sensing aniline derivatives.
Collapse
Affiliation(s)
- Maria Rosaria di Nunzio
- Departamento de Química Física, Facultad de Ciencias Ambientales y Bioquímica, and INAMOL, Universidad de Castilla-La Mancha, Av. Carlos III, s/n, 45071 Toledo, Spain; (M.R.d.N.); (M.G.)
| | - Mario Gutiérrez
- Departamento de Química Física, Facultad de Ciencias Ambientales y Bioquímica, and INAMOL, Universidad de Castilla-La Mancha, Av. Carlos III, s/n, 45071 Toledo, Spain; (M.R.d.N.); (M.G.)
| | - José María Moreno
- Instituto de Tecnología Química, Universitat Politécnica de Valéncia-Consejo Superior de Investigaciones Científicas (UPV-CSIC), Av. de los Naranjos, s/n, 46022 Valencia, Spain; (J.M.M.); (A.C.); (U.D.)
| | - Avelino Corma
- Instituto de Tecnología Química, Universitat Politécnica de Valéncia-Consejo Superior de Investigaciones Científicas (UPV-CSIC), Av. de los Naranjos, s/n, 46022 Valencia, Spain; (J.M.M.); (A.C.); (U.D.)
| | - Urbano Díaz
- Instituto de Tecnología Química, Universitat Politécnica de Valéncia-Consejo Superior de Investigaciones Científicas (UPV-CSIC), Av. de los Naranjos, s/n, 46022 Valencia, Spain; (J.M.M.); (A.C.); (U.D.)
| | - Abderrazzak Douhal
- Departamento de Química Física, Facultad de Ciencias Ambientales y Bioquímica, and INAMOL, Universidad de Castilla-La Mancha, Av. Carlos III, s/n, 45071 Toledo, Spain; (M.R.d.N.); (M.G.)
- Correspondence:
| |
Collapse
|
49
|
Zhang J, Lei C, Liang T, Liu R, Zhao Z, Qi L, Ghaffar A, Xiong J. Acetone Sensor Based on FAIMS-MEMS. MICROMACHINES 2021; 12:1531. [PMID: 34945383 PMCID: PMC8703384 DOI: 10.3390/mi12121531] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 12/02/2021] [Accepted: 12/05/2021] [Indexed: 12/02/2022]
Abstract
In this paper, to address the problems of large blood draws, long testing times, and the inability to achieve dynamic detection of invasive testing for diabetes, stemming from the principle that type 1 diabetic patients exhale significantly higher levels of acetone than normal people, a FAIMS-MEMS gas sensor was designed to detect acetone, which utilizes the characteristics of high sensitivity, fast response, and non-invasive operation. It is prepared by MEMS processes, such as photolithography, etching, and sputtering, its specific dimensions are 4000 μm in length, 3000 μm in width and 800 μm in height and the related test system was built to detect acetone gas. The test results show that when acetone below 0.8 ppm is introduced, the voltage value detected by the sensor basically does not change, while when acetone gas exceeds 1.8 ppm, the voltage value detected by the sensor increases significantly. The detection accuracy of the sensor prepared by this method is about 0.02 ppm/mV, and the voltage change can reach 1 V with a response time of 3 s and a recovery time of 4 s when tested under 20 ppm acetone environment; this has good repeatability and stability, and has great prospects in the field of non-invasive detection of type 1 diabetes.
Collapse
Affiliation(s)
- Junna Zhang
- State Key Laboratory of Dynamic Measurement Technology, North University of China, Taiyuan 030051, China; (J.Z.); (Z.Z.); (J.X.)
| | - Cheng Lei
- State Key Laboratory of Dynamic Measurement Technology, North University of China, Taiyuan 030051, China; (J.Z.); (Z.Z.); (J.X.)
| | - Ting Liang
- State Key Laboratory of Dynamic Measurement Technology, North University of China, Taiyuan 030051, China; (J.Z.); (Z.Z.); (J.X.)
| | - Ruifang Liu
- State Key Laboratory of Bioelectronics, Southeast University, Nanjing 210096, China;
| | - Zhujie Zhao
- State Key Laboratory of Dynamic Measurement Technology, North University of China, Taiyuan 030051, China; (J.Z.); (Z.Z.); (J.X.)
| | - Lei Qi
- North Automatic Control Technology Institute, Taiyuan 030006, China;
| | - Abdul Ghaffar
- State Key Laboratory of Geomechanics and Geotechnical Engineering, Institute of Rock and Soil Mechanics, Chinese Academy of Sciences, Wuhan 430071, China;
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jijun Xiong
- State Key Laboratory of Dynamic Measurement Technology, North University of China, Taiyuan 030051, China; (J.Z.); (Z.Z.); (J.X.)
| |
Collapse
|
50
|
Dixit K, Fardindoost S, Ravishankara A, Tasnim N, Hoorfar M. Exhaled Breath Analysis for Diabetes Diagnosis and Monitoring: Relevance, Challenges and Possibilities. BIOSENSORS 2021; 11:476. [PMID: 34940233 PMCID: PMC8699302 DOI: 10.3390/bios11120476] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 11/18/2021] [Accepted: 11/20/2021] [Indexed: 05/15/2023]
Abstract
With the global population prevalence of diabetes surpassing 463 million cases in 2019 and diabetes leading to millions of deaths each year, there is a critical need for feasible, rapid, and non-invasive methodologies for continuous blood glucose monitoring in contrast to the current procedures that are either invasive, complicated, or expensive. Breath analysis is a viable methodology for non-invasive diabetes management owing to its potential for multiple disease diagnoses, the nominal requirement of sample processing, and immense sample accessibility; however, the development of functional commercial sensors is challenging due to the low concentration of volatile organic compounds (VOCs) present in exhaled breath and the confounding factors influencing the exhaled breath profile. Given the complexity of the topic and the skyrocketing spread of diabetes, a multifarious review of exhaled breath analysis for diabetes monitoring is essential to track the technological progress in the field and comprehend the obstacles in developing a breath analysis-based diabetes management system. In this review, we consolidate the relevance of exhaled breath analysis through a critical assessment of current technologies and recent advancements in sensing methods to address the shortcomings associated with blood glucose monitoring. We provide a detailed assessment of the intricacies involved in the development of non-invasive diabetes monitoring devices. In addition, we spotlight the need to consider breath biomarker clusters as opposed to standalone biomarkers for the clinical applicability of exhaled breath monitoring. We present potential VOC clusters suitable for diabetes management and highlight the recent buildout of breath sensing methodologies, focusing on novel sensing materials and transduction mechanisms. Finally, we portray a multifaceted comparison of exhaled breath analysis for diabetes monitoring and highlight remaining challenges on the path to realizing breath analysis as a non-invasive healthcare approach.
Collapse
Affiliation(s)
- Kaushiki Dixit
- Department of Electronics and Electrical Communication Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India;
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada; (S.F.); (A.R.); (N.T.)
| | - Somayeh Fardindoost
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada; (S.F.); (A.R.); (N.T.)
| | - Adithya Ravishankara
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada; (S.F.); (A.R.); (N.T.)
| | - Nishat Tasnim
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada; (S.F.); (A.R.); (N.T.)
- Faculty of Engineering and Computer Science, University of Victoria, Victoria, BC V8W 2Y2, Canada
| | - Mina Hoorfar
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada; (S.F.); (A.R.); (N.T.)
- Faculty of Engineering and Computer Science, University of Victoria, Victoria, BC V8W 2Y2, Canada
| |
Collapse
|