1
|
Jurado CA, Tsujimoto A, Rojas-Rueda S, Mekled S, Alaqeely R, Alsayed HD, Alhotan A. Fracture resistance of ultratranslucent multilayered zirconia veneers with different facial thicknesses. Microsc Res Tech 2024; 87:2811-2817. [PMID: 39003769 DOI: 10.1002/jemt.24649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Revised: 05/22/2024] [Accepted: 06/30/2024] [Indexed: 07/16/2024]
Abstract
To assess the fracture resistance of computer-aided design and computer-aided manufacturing (CAD/CAM) ultratranslucent multilayered zirconia (5Y-YZP) veneers with varying facial thickness. Sixty translucent zirconia veneers were designed and milled using a chairside CAD/CAM system for maxillary central incisors. The butt joint incisal veneer tooth preparations consisted of 1.00 mm incisal reduction, 0.40 mm chamfer margin, and three different facial reductions; 0.50, 0.75, and 1 mm, respectively. The ceramic veneers were cemented to printed resin dies and subjected to thermal cycling. Subsequently, the restorations were loaded with compressive loading force, and fracture occurrences were recorded. Scanning electron microscope (SEM) images of the fractured specimens were captured. The fracture resistance varied among the veneers with different facial thicknesses. Ultratranslucent zirconia veneers with a facial thickness of 1.00 mm exhibited the highest fracture resistance values (742.15 N), followed by those with 0.75 mm facial thickness (673 N). Minimally invasive veneers with 0.50 mm thickness displayed similar fracture resistance as thicker veneers with 0.75 mm. However, veneers with 1.00 mm thickness displayed the highest values. SEM fracture patterns for 0.50 and 0.75 mm display similar and fewer crack lines than 1.00 mm veneers. RESEARCH HIGHLIGHTS: Minimally invasive zirconia veneers exhibit similar fracture resistance to thicker veneers.
Collapse
Affiliation(s)
- Carlos A Jurado
- Division of Operative Dentistry, Department of General Dentistry, University of Tennessee Health Science Center College of Dentistry, Memphis, Tennessee, USA
| | - Akimasa Tsujimoto
- Department of Operative Dentistry, Aichi Gakuin University School of Dentistry, Nagoya, Japan
- Department of Operative Dentistry, College of Dentistry, University of Iowa, Iowa City, Iowa, USA
- Department of General Dentistry, School of Dentistry, Creighton University, Omaha, Nebraska, USA
| | - Silvia Rojas-Rueda
- Division of Dental Biomaterials, Department of Restorative Sciences, University of Alabama at Birmingham School of Dentistry, Birmingham, Alabama, USA
| | - Salwa Mekled
- Temple University Kornberg School of Dentistry, Philadelphia, Pennsylvania, USA
| | - Razan Alaqeely
- Department of Periodontology and Community Dentsitry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Hussain D Alsayed
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Abdulaziz Alhotan
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
2
|
Zhou Y, Chen W, Zhu H, Liu X, Yang H, He F. Effect of machining method and margin design on the accuracy and margin quality of monolithic zirconia crowns. J Prosthet Dent 2024:S0022-3913(24)00701-7. [PMID: 39496534 DOI: 10.1016/j.prosdent.2024.10.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 10/04/2024] [Accepted: 10/10/2024] [Indexed: 11/06/2024]
Abstract
STATEMENT OF PROBLEM The machining accuracy and marginal integrity of monolithic zirconia crowns with minimal invasive preparations may impact the long-term survival rate of tooth and periodontal health, but studies on the effect of machining method are lacking. PURPOSE The purpose of this in vitro study was to digitally evaluate the machining accuracy and margin quality of monolithic zirconia crowns fabricated using gel deposition and conventional soft milling processes by comparing 2 different margin types. MATERIAL AND METHODS A total of 40 monolithic zirconia crowns were produced using gel deposition (Self-glazed Zirconia Group, SGG, n=20) and soft milling (Milled Zirconia Group, MG, n=20). Each group was further divided into 2 subgroups with different margin designs (chamfer and feather-edge). The trueness and fit of crowns were compared using root mean square (RMS) values. Furthermore, the margin quality was examined before and after final sintering with a scanning electron microscope (SEM). The Scheirer-Ray-Hare and 2-way ANOVA test analysis nonparametric and parametric data, respectively (α=.05). RESULTS The trueness analysis revealed that SGG had significantly lower RMS values for both the cameo and intaglio areas compared with MG (P<.001). In addition, crowns with a feather-edge margin exhibited significantly lower marginal RMS values than those with a chamfer margin (P<.01) according to the fit assessment. Followed by milling processes, SGG exhibited a constantly homogeneous microstructure compared with MG. Marginal defects were detected in both groups except for the SGG with the chamfer margin. CONCLUSIONS SGG exhibited better accuracy associated with ductile-regime machining than MG, and SGG with chamfer margins displayed flaw-free margin areas. Moreover, the feather-edge margin showed improved marginal fit compared with the chamfer margin.
Collapse
Affiliation(s)
- Yi Zhou
- Attending, Department of Prosthodontics, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, PR China
| | - Wenjia Chen
- Graduate student, Department of Prosthodontics, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, PR China
| | - Han Zhu
- Graduate student, Department of Prosthodontics, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, PR China
| | - Xiaochen Liu
- Associate Chief, Department of Prosthodontics, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, PR China
| | - Haiping Yang
- Associate Chief, Department of Prosthodontics, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, PR China
| | - Fuming He
- Professor, Department of Prosthodontics, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, PR China.
| |
Collapse
|
3
|
Opatragoon S, Klaisiri A, Sriamporn T, Thamrongananskul N. Comparison of the Shear Bond Strength Using Primers with Different Application Numbers on Dental Zirconia. Eur J Dent 2024; 18:1004-1011. [PMID: 39013446 PMCID: PMC11479738 DOI: 10.1055/s-0043-1777821] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/18/2024] Open
Abstract
OBJECTIVE This study examined the effect of the number of phosphate-containing primer applications on the shear bond strength (SBS) of zirconia to resin cement. MATERIALS AND METHODS 315 square specimens (10 × 10 × 4 mm3) were manufactured from Cercon ht presintered zirconia blocks. Alumina particles were used to sandblast zirconia specimens. These specimens were randomly divided into six primer-based groups: No primer application (NP), CLEARFIL CERAMIC PRIMER (C), PANAVIA V5 Tooth Primer (T), M&C PRIMER (MC), Monobond N (MN), and Z-PRIME plus (Z), and then separated into application number (1-4) groups (excluding NP). Each specimen was bonded with resin cement. The SBS was measured using a universal testing machine. The debonded surface was examined with a stereomicroscope. STATISTICAL ANALYSIS The SBSs were analyzed using two-way analysis of variance. RESULTS Applying the primer twice exhibited the highest SBSs in each group, with significant differences in the T, MN, and Z groups. However, the SBS in the MC group was significantly lower on the second application. One-hundred percent adhesive failure was observed in all groups. CONCLUSION Within the limitations of this study, prior to cementation, the sandblasted zirconia surface should be applied twice with a phosphate-containing primer other than MC to maximize the SBS at the zirconia-resin cement interface.
Collapse
Affiliation(s)
- Suphakit Opatragoon
- Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Awiruth Klaisiri
- Division of Restorative Dentistry, Faculty of Dentistry, Thammasat University, Pathum Thani, Thailand
| | - Tool Sriamporn
- Department of Prosthodontics, College of Dental Medicine, Rangsit University, Pathum Thani, Thailand
| | - Niyom Thamrongananskul
- Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
4
|
Alqutaibi AY, Alghauli MA, Almuzaini SA, Alharbi AF, Alsani AA, Mubarak AM, Alhajj MN. Failure and complication rates of different materials, designs, and bonding techniques of ceramic cantilever resin-bonded fixed dental prostheses for restoring missing anterior teeth: A systematic review and meta-analysis. J ESTHET RESTOR DENT 2024; 36:1396-1411. [PMID: 38623053 DOI: 10.1111/jerd.13238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2024] [Revised: 03/30/2024] [Accepted: 04/03/2024] [Indexed: 04/17/2024]
Abstract
OBJECTIVES The objective of this review was to assess clinical trials that have examined the materials, design, and bonding of ceramic cantilevered resin-bonded fixed dental prostheses (RBFDPs) as a potential option for replacing missing anterior teeth. The evaluation primarily focuses on the rate of restoration failure and clinical complications. MATERIALS AND METHODS A thorough search of databases including PubMed/MEDLINE, Scopus, and the Cochrane Library, was conducted. The most recent search was performed in October 2023. Clinical studies that compared ceramic cantilevered RBFDPs with double retainers or cantilevered RBFDPs using different ceramic materials or bonding systems were included. The outcome measures considered were restoration failure and complication rates. RESULTS Twelve studies met the eligibility criteria. The pooled data showed a statistically significant decrease in complication events when using cantilever designs compared with double retainer designs (p < 0.05); however, there were no differences found between the two designs in terms of restoration failure. The complication and failure rate of cantilever RBFDPs did not show a statistically significant difference with or without ceramic primer application before luting with phosphate monomer-containing luting resin (p > 0.05). CONCLUSIONS Ceramic cantilevered RBFDPs have lower complication rates compared with those with double retainers. The use of a ceramic primer prior to luting composite resin for ceramic cantilevered RBFDPs decreases the occurrence of complications and failures, although this effect was not statistically significant. Additional research is required to confirm these findings. Glass ceramic cantilever RBFDPs showed a decrease in success after 6 years, requiring ongoing monitoring, but both zirconia and glass-infiltrated alumina cantilever RBFDPs have demonstrated durability with excellent long-term success and survival rates for up to 10 and 15 years. CLINICAL SIGNIFICANCE Cantilever ceramic RBFDPs in the anterior region are a less invasive and valuable treatment option, providing good esthetic results.
Collapse
Affiliation(s)
- Ahmed Yaseen Alqutaibi
- Substitutive Dental Science Department, College of Dentistry, Taibah University, Al-Madinah, Saudi Arabia
- Department of Prosthodontics, Faculty of Dentistry, Ibb University, Ibb, Yemen
| | | | | | | | | | - Arwa M Mubarak
- College of Dentistry, Taibah University, Al-Madinah, Saudi Arabia
| | | |
Collapse
|
5
|
Borzangy S, Bahabri RH, Alsani AA, Alqutaibi AY, Alghauli MA, AbdElaziz MH. Cutting efficiency of different dental diamond rotary instruments for sectioning monolithic zirconia and lithium disilicate crowns. BMC Oral Health 2024; 24:1135. [PMID: 39334035 PMCID: PMC11437972 DOI: 10.1186/s12903-024-04901-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2024] [Accepted: 09/11/2024] [Indexed: 09/30/2024] Open
Abstract
BACKGROUND The aim of this study was to determine the cutting efficiency of different diamond rotary instrument types for sectioning monolithic zirconia and lithium disilicate anatomical crowns. MATERIALS AND METHODS The study used 30 diamond rotary instruments divided into three groups: Zirconia cutting diamond bur (White Z), super coarse grit diamond bur (KBlack), and medium coarse grit diamond bur (KBlue); Two subgroups were assigned based on the crown materials including monolithic zirconia (5YSZ) and lithium disilicate (e.max) ceramics. The cutting efficiency was assessed by measuring the time required to fully section the crowns, followed by scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS) of the dental burs before use and after every sectioned crown. A three-way ANOVA examined the effects of bur type, material type, and sectioning stage. If interaction exists, one-way ANOVA was used to compare the different subgroups, followed by the Tukey post hoc test. The significance level was assigned at α ≤ 0.05. RESULTS The results exhibited various cutting efficiencies among diamond rotary instruments and ceramic crown materials. White Z demonstrated superior cutting efficiency of zirconia crown compared with KBlack and KBlue for the first cutting cycles (p ≤ 0.05); the results tend to be more comparable at the third cutting cycle. However, the super coarse diamond bur exhibited higher efficiency in cutting lithium disilicate crowns than white Z and KBlue burs through all three cutting cycles(p ≤ 0.05). The diamond bur-cutting efficiency diminished after each use, irrespective of the bur type or the crown material (p ≤ 0.05); this was represented by the reduction of carbon and increased nickel matrix ratio after each bur usage. CONCLUSION White Z diamond bur showed higher cutting efficiency of zirconia in the first two cutting cycles; super coarse diamond bur is more efficient for cutting lithium disilicate crown in all of the cutting cycles. The amount of diamond on the burs reduced after each use, with no great impact on the material type when sectioning lithium disilicate and 5YSZ crowns. CLINICAL SIGNIFICANCE This study provides valuable insights for dental practitioners in selecting the appropriate diamond rotary instrument for crown sectioning. Practitioners can minimize the risk of damage and reduce the time required for crown removal, improving patient outcomes.
Collapse
Affiliation(s)
- Sary Borzangy
- Substitutive Dental Science Department, College of Dentistry, Taibah University, Al Madinah, Saudi Arabia
| | - Rayan Hassan Bahabri
- Department of Endodontics, College of Dentistry, Taibah University, Al Madinah, Saudi Arabia
| | | | - Ahmed Yaseen Alqutaibi
- Substitutive Dental Science Department, College of Dentistry, Taibah University, Al Madinah, Saudi Arabia.
- Department of Prosthodontics, College of Dentistry, Ibb University, Ibb, Yemen.
| | | | - Mohammed H AbdElaziz
- Substitutive Dental Science Department, College of Dentistry, Taibah University, Al Madinah, Saudi Arabia
- Crown and Bridge Department, Faculty of Dental Medicine, Al-Azhar University, Cairo, Egypt
| |
Collapse
|
6
|
Ansarifard E, Taghva M, Mosaddad SA, Akhlaghian M. The impact of various substrates, ceramic shades, and brands on the ultimate color and masking capacity of highly translucent monolithic zirconia: an in vitro study. Odontology 2024:10.1007/s10266-024-00996-0. [PMID: 39222097 DOI: 10.1007/s10266-024-00996-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Accepted: 08/15/2024] [Indexed: 09/04/2024]
Abstract
This study aimed to examine the impact of substrates, ceramic shades, and brands on the color and masking ability of highly translucent monolithic zirconia (HTMZ) using CIELab and CIEΔE2000 metrics. A total of 156 1-mm thick HTMZ disks in shades A1, A2, and A3 were produced using Dental Direkt and Kerox zirconia brands. Four 3-mm thick substrates (nickel-chromium alloy, non-precious gold alloy (NPG), zirconia shade A2, and resin composite shade A2) were prepared. HTMZ disks were overlaid on these substrates, and color measurements were taken with a spectrophotometer. Color differences (ΔE) were analyzed using CIELab and CIEΔE2000 formulas. The influence of brand, shade, substrate, and their interactions on ΔE values was assessed with a General Linear Model (GLM) and LSD pairwise comparison test. Spearman's correlation test examined the relationship between CIELab and CIEΔE2000 values. Results indicated that ΔEab was significantly influenced by substrate type and shade, while ΔE2000 was also affected by the ceramic brand. Mean color differences across ceramic-substrate groups were within clinically acceptable and perceptible ranges (clinically perceptible: ∆Eab ≥ 1.3 and ∆E2000 ≥ 0.8; clinically acceptable: 0.8 < ∆E2000 ≤ 1.8 and 1.3 < ∆Eab ≤ 2.7), except for NPG, which had ΔE values exceeding the perceptible range (ΔE2000: 1.1 ± 0.11 to 1.8 ± 0.31; ΔEab: 1.61 ± 0.15 to 2.16 ± 0.36). A significant correlation (r = 0.974, P < 0.001) was found between ΔEab and ΔE2000. Various ceramic brands and shades led to notable ΔE variations, yet average color differences within all ceramic-substrate groups remained clinically acceptable. Both ΔEab and ΔE2000 were reliable methods with a strong correlation for measuring color differences.
Collapse
Affiliation(s)
- Elham Ansarifard
- Department of Prosthodontics, Biomaterials Research Center, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Masumeh Taghva
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Seyed Ali Mosaddad
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
- Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India.
- Student Research Committee, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
- Department of Conservative Dentistry and Bucofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain.
| | - Marzieh Akhlaghian
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
| |
Collapse
|
7
|
Refaie A, Bourauel C, Elshazly T, Evers-Dietze B, Alhotan A, Aldesoki M. Trueness and precision of digital light processing fabricated 3D printed monolithic zirconia crowns. J Dent 2024; 148:105151. [PMID: 38909644 DOI: 10.1016/j.jdent.2024.105151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 06/18/2024] [Accepted: 06/21/2024] [Indexed: 06/25/2024] Open
Abstract
OBJECTIVES The present study aimed to evaluate the trueness and precision of monolithic zirconia crowns (MZCs) fabricated by 3D printing and milling techniques. METHODS A premolar crown was designed after scanning a prepared typodont. Twenty MZCs were fabricated using milling and 3D-printing techniques (n = 10). All the specimens were scanned with an industrial scanner, and the scanned data were analyzed using 3D measurement software to evaluate the trueness and precision of each group. Root mean square (RMS) deviations were measured and statistically analyzed (One-way ANOVA, Tukey's, p ≤ 0.05). RESULTS The trueness of the printed MZC group (140 ± 14 μm) showed a significantly higher RMS value compared to the milled MZCs (96 ± 27 μm,p < 0.001). At the same time, the precision of the milled MZCs (61 ± 17 μm) showed a significantly higher RMS value compared to that of the printed MZCs (31 ± 5 μm,p < 0.001). CONCLUSIONS The Fabrication techniques had a significant impact on the accuracy of the MZCs. Milled MZCs showed the highest trueness, while printed MZCs showed the highest precision. All the results were within the clinically acceptable error values. CLINICAL SIGNIFICANCE Although the trueness of the milled MZCs is higher, the manufacturing accuracy of the 3D-printed MZCs showed clinically acceptable results in terms of trueness and precision. However, additional clinical studies are recommended. Furthermore, the volumetric changes of the material should be considered.
Collapse
Affiliation(s)
- Ashraf Refaie
- Oral Technology, Dental School, University Hospital Bonn, Bonn, Germany; Department of Fixed Prosthodontics, Faculty of Dentistry, Fayoum University, Egypt.
| | | | - Tarek Elshazly
- Oral Technology, Dental School, University Hospital Bonn, Bonn, Germany
| | - Bernd Evers-Dietze
- Department of Electrical Engineering, Mechanical Engineering and Technical Journalism (EMT), Bonn-Rhein-Sieg University of Applied Sciences, Sankt Augustin, Germany
| | - Abdulaziz Alhotan
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Mostafa Aldesoki
- Oral Technology, Dental School, University Hospital Bonn, Bonn, Germany
| |
Collapse
|
8
|
Wang Y, Zhang J, Yu H, Ding N, Ma P, Zeng B. Photothermal modulation of gingival fibroblasts via polydopamine-coated zirconia: A novel approach for promoting peri-implant soft tissue integration. JOURNAL OF STOMATOLOGY, ORAL AND MAXILLOFACIAL SURGERY 2024; 125:101925. [PMID: 38815725 DOI: 10.1016/j.jormas.2024.101925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Accepted: 05/27/2024] [Indexed: 06/01/2024]
Abstract
Achieving robust soft tissue integration around dental implants is crucial for long-term clinical success, as it forms a protective biological seal against bacterial invasion. However, the soft tissue attachment to implants is relatively deficient compared to natural teeth, particularly in the connective tissue region lacking sufficient gingival fibroblasts and collagen fiber alignment. This study proposed an innovative strategy to enhance peri‑implant soft tissue integration by modulating gingival fibroblast behavior via photothermal conversion. Zirconia surfaces were coated with polydopamine (PDA), a melanin-like polymer exhibiting near-infrared (NIR) absorption for photothermal conversion. Under NIR irradiation, the PDA coating enabled mild hyperthermia (42-43 °C) on the zirconia surface. Remarkably, this mild photothermal stimulation significantly promoted human gingival fibroblast proliferation, adhesion, and collagen production compared to unmodified zirconia in vitro. By utilizing the photothermal properties of PDA coatings to modulate cellular behaviors beneficial for connective tissue formation, this approach provides a promising avenue to achieve improved soft tissue integration and long-term stability of dental implants. The findings highlight the innovative potential of combining biomaterial surface engineering with photothermal therapy for applications in implant dentistry.
Collapse
Affiliation(s)
- Yijia Wang
- School of Stomatology, Capital Medical University, Tiantan Xili No.4, Beijing 100050, PR China
| | - Jiebing Zhang
- School of Stomatology, Capital Medical University, Tiantan Xili No.4, Beijing 100050, PR China
| | - Haoyan Yu
- The First Clinical Faculty, Guangxi University of Chinese Medicine, Mingxiu East Road NO.179, Nanning 530000, PR China
| | - Ning Ding
- School of Stomatology, Capital Medical University, Tiantan Xili No.4, Beijing 100050, PR China
| | - Ping Ma
- School of Stomatology, Capital Medical University, Tiantan Xili No.4, Beijing 100050, PR China
| | - Baijin Zeng
- School of Stomatology, Capital Medical University, Tiantan Xili No.4, Beijing 100050, PR China.
| |
Collapse
|
9
|
Fathi A, Natanzian Y, Ghorbani M, Mosharraf R. Evaluation of the Bonding Shear Strength between Enamel and Dentin Feldspathic Porcelain and Two Different Monolithic Zirconia with Low and High Translucency. Int J Dent 2024; 2024:5921637. [PMID: 39148645 PMCID: PMC11326879 DOI: 10.1155/2024/5921637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 05/25/2024] [Accepted: 07/17/2024] [Indexed: 08/17/2024] Open
Abstract
Introduction The utilization of ceramics in the field of dentistry has seen a significant rise owing to their esthetic appeal and excellent functional properties. The use of ceramics in the field of dentistry has witnessed a notable surge, driven by their appealing esthetics and exceptional functional attributes. Zirconia, distinguished by its exceptional mechanical strength, plays a pivotal role in the fabrication of posterior crowns and bridges. Among zirconia variants, monolithic zirconia stands out, where the entire restoration is crafted from zirconia material. In parallel, feldspathic porcelain, chosen for its remarkable resemblance to natural tooth enamel, represents another significant ceramic type. This study aims to evaluate the shear bond strength (SBS) between two types of monolithic zirconia with two types of feldspathic porcelain. Methods and Materials Forty-four monolithic zirconia veneered discs with feldspathic porcelain were subjected to SBS testing. The dimensions of the discs were 7 mm in diameter and 5 mm in height (3 mm of zirconia and 2 mm of porcelain). Subsequently, the specimens were subjected to a universal testing machine at a speed of 0.5 mm/min until failure occurred. The type of failure was examined using scanning electron microscopy. One-way analysis of variance (ANOVA), two-way ANOVA, Fisher's test, and multiple Tukey comparisons were used as statistical analyses. Results The highest SBS was achieved by the high-translucency monolithic zirconia with enamel porcelain group (18.81 ± 3.18 MPa) and the high-translucency monolithic zirconia with dentin porcelain group (17.89 ± 2.75 MPa), followed by the low-translucency monolithic zirconia with dentin porcelain group (15.04 ± 2.24 MPa) and the low-translucency monolithic zirconia with enamel porcelain group (14.33 ± 2.00 MPa), respectively. Additionally, the most common type of failure pattern observed was mixed, followed by adhesive failure. Conclusion The translucency of the porcelain did not significantly affect SBS, while the type of monolithic zirconia used had a significant impact. Furthermore, there was no discernible relationship between the four groups in terms of the distribution of failure patterns.
Collapse
Affiliation(s)
- Amirhossein Fathi
- Department of Prosthodontics Dental Materials Research Center Isfahan University of Medical Sciences, Isfahan, Iran
| | - Yeganeh Natanzian
- Dental Students' Research Committee School of Dentistry Isfahan University of Medical Sciences, Isfahan, Iran
| | - Mahsa Ghorbani
- School of Dentistry Mashhad University of Medical Sciences, Mashhad, Iran
| | - Ramin Mosharraf
- Department of Prosthodontics Dental Materials Research Center Isfahan University of Medical Sciences, Isfahan, Iran
| |
Collapse
|
10
|
Alghauli MA, Alqutaibi AY, Wille S, Kern M. The physical-mechanical properties of 3D-printed versus conventional milled zirconia for dental clinical applications: A systematic review with meta-analysis. J Mech Behav Biomed Mater 2024; 156:106601. [PMID: 38810545 DOI: 10.1016/j.jmbbm.2024.106601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Revised: 05/12/2024] [Accepted: 05/23/2024] [Indexed: 05/31/2024]
Abstract
AIM OF STUDY This systematic review aimed to compare the physical-mechanical properties of 3D-printed (additively manufactured (AM)) zirconia compared to conventionally milled (subtractive manufactured: SM) zirconia specimens. MATERIALS AND METHODS A thorough search of Internet databases was conducted up to September 2023. The search retrieved studies that evaluated AM zirconia specimens and restorations regarding the physical-mechanical properties and mechanical behavior of zirconia. The main topic focused on 3Y-TZP. However, records of 4YSZ and 5YSZ were also included to gather more comprehensive evidence on additively manufactured zirconia ceramic. The quality of studies was assessed using the ROB2 tool, Newcastle Ottawa scale, and the Modified Consort Statement. Of 1736 records, 57 were assessed for eligibility, and 38 records were included in this review, only two clinical trials meet the inclusion criteria and 36 records were laboratory studies. There were no signs of mechanical complications and wear to antagonists with short-term clinical observation. SM thin specimens ≤1.5 mm showed statistically significant higher flexural strength than AM zirconia (p ≤ 0.01), while thicker specimens showed comparable outcomes (p > 0.5). The fracture resistance of dental restorations was dependent on the aging protocol, restoration type, and thickness. The bond strength of veneering ceramic to zirconia core was comparable. CONCLUSIONS The results pooled from two short-term clinical trials showed no signs of mechanical or biological complications of additively manufactured 3Y-TZP zirconia crowns. The flexural strength might depend on the specimens' thickness, but it showed promising results to be used in clinical applications, taking into account the printing technique and orientation, material composition (yttria content), solid loading, and sintering parameters. 3D-printed restorations fracture resistance improved when adhered to human teeth. The veneering ceramic bond was comparable to milled zirconia specimens. Long-term RCTs are recommended to confirm the mechanical behavior of 3D-printed restorations.
Collapse
Affiliation(s)
- Mohammed Ahmed Alghauli
- Department of Prosthodontic, Propaedeutic and Dental Materials, Faculty of Dentistry, Kiel University, Kiel, Germany; Department of Prosthodontics, Faculty of Dentistry, Ibb University, Ibb, Yemen.
| | - Ahmed Yaseen Alqutaibi
- Department of Prosthodontics, Faculty of Dentistry, Ibb University, Ibb, Yemen; Department of Substitutive Dental Science, College of Dentistry, Taibah University, Al-Madinah, Saudi Arabia
| | - Sebastian Wille
- Department of Prosthodontic, Propaedeutic and Dental Materials, Faculty of Dentistry, Kiel University, Kiel, Germany
| | - Matthias Kern
- Department of Prosthodontic, Propaedeutic and Dental Materials, Faculty of Dentistry, Kiel University, Kiel, Germany
| |
Collapse
|
11
|
Huang B, Chen M, Wang J, Zhang X. Advances in zirconia-based dental materials: Properties, classification, applications, and future prospects. J Dent 2024; 147:105111. [PMID: 38866229 DOI: 10.1016/j.jdent.2024.105111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 06/04/2024] [Accepted: 06/06/2024] [Indexed: 06/14/2024] Open
Abstract
OBJECTIVES Zirconia (ZrO2) ceramics are widely used in dental restorations due to their superior mechanical properties, durability, and ever-improving translucency. This review aims to explore the properties, classification, applications, and recent advancements of zirconia-based dental materials, highlighting their potential to revolutionize dental restoration techniques. STUDY SELECTION, DATA AND SOURCES The most recent literature available in scientific databases (PubMed and Web of Science) reporting advances of zirconia-based materials within the dental field is thoroughly examined and summarized, covering the major keywords "dental zirconia, classification, aesthetic, LTD, applications, manufacturing, surface treatments". CONCLUSIONS An exhaustive overview of the properties, classifications, and applications of dental zirconia was presented, alongside an exploration of future prospects and potential advances. This review highlighted the importance of addressing challenges such as low-temperature degradation resistance and optimizing the balance between mechanical strength and translucency. Also, innovative approaches to improve the performances of zirconia as dental material was discussed. CLINICAL SIGNIFICANCE This review provides a better understanding of zirconia-based dental biomaterials for dentists, helping them to make better choice when choosing a specific material to fabricate the restorations or to place the implant. Moreover, new generations of zirconia are still expected to make progress on key issues such as the long-term applications in dental materials while maintaining both damage resistance and aesthetic appeal, defining the directions for future research.
Collapse
Affiliation(s)
- Bo Huang
- State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan, China
| | - Mengbing Chen
- State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan, China
| | - Jian Wang
- State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan, China.
| | - Xin Zhang
- State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan, China.
| |
Collapse
|
12
|
Makwana SL, Vaishnav K, Joshi R, Patel TH, Vora NN, Sachde NH, Vala KA, Raval Z, Yohannan JA, Joshi VJ. The Surface Deterioration of Prefabricated Zirconia Crowns on Exposure to Acidulated Phosphate Fluoride Gel: An In Vitro Study. Cureus 2024; 16:e66371. [PMID: 39246859 PMCID: PMC11378743 DOI: 10.7759/cureus.66371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2024] [Accepted: 08/07/2024] [Indexed: 09/10/2024] Open
Abstract
Introduction Zirconia is a widely used restorative material in dentistry due to its superior aesthetic and mechanical properties. The oral cavity is a complex ecosystem with various components, which affect the teeth, as well as artificial restorative materials. Various personal and professional interventions carried out can severely affect the properties of restorative materials, thus altering the longevity of the prosthesis; 1.23% acidulated phosphate fluoride (APF) gel is one such professionally applied topical fluoride agent used to prevent caries. The interaction of this APF gel with highly aesthetic restorative material such as zirconia crowns is unknown. Objective The objective of this study is the evaluation of the surface deterioration of prefabricated zirconia crowns on exposure to deionised water and 1.23% acidulated phosphate fluoride (APF) gel with field emission scanning electron microscope (FE-SEM) and mass loss analysis. Material and method Sixty prefabricated paediatric zirconia crowns were taken, 10 samples were immersed in deionised water, 40 samples were immersed in 1.23% APF gel and 10 samples were used as control. Surface morphology and mass loss analysis were carried out at time intervals of four minutes, 24 hours, 48 hours and 72 hours using FE-SEM and digital weighing machine. Results No visual change was observed in the samples immersed in deionised water at the time interval of 72 hours. There was a marked visual change in samples immersed in 1.23% APF gel at the time interval of four minutes to 72 hours; this change involved a loss of gloss to the appearance of chalkiness. FE-SEM analysis for the control group and samples immersed in deionised water showed a smooth, continuous, undisrupted top layer, while samples immersed in 1.23% APF gel showed changes ranging from surface etching, to pinhole porosities, to crack formation and disruption of the surface depending upon the exposure time. Conclusions On the immersion of zirconia crowns in an aqueous acidic medium of 1.23% APF gel, the crowns showed flaws, imperfections and uneven superficial layers. It has been observed that surface grains are disrupted and micropores have been formed. This degraded superficial surface when undergoes cyclic mechanical loading can accelerate the ageing phenomenon of zirconia. Mechanical forces along with a dynamic electrochemical environment can degrade the material properties of zirconia.
Collapse
Affiliation(s)
- Sanidhya L Makwana
- Department of Prosthodontics, Crown and Bridge, Karnavati School of Dentistry, Gandhinagar, IND
| | - Kalpesh Vaishnav
- Department of Prosthodontics, Crown and Bridge, Karnavati School of Dentistry, Gandhinagar, IND
| | - Ravi Joshi
- Department of Prosthodontics, Crown and Bridge, Karnavati School of Dentistry, Gandhinagar, IND
| | - Tulsi H Patel
- Department of Prosthodontics, Crown and Bridge, Karnavati School of Dentistry, Gandhinagar, IND
| | - Neil N Vora
- Department of Prosthodontics, Crown and Bridge, Karnavati School of Dentistry, Gandhinagar, IND
| | - Nishit H Sachde
- Department of Dentistry, University of the Pacific, San Francisco, USA
| | - Keyur A Vala
- Department of Conservative Dentistry and Endodontics, Government Dental College and Hospital, Ahmedabad, IND
| | - Zalak Raval
- Department of Prosthodontics, Crown and Bridge, Karnavati School of Dentistry, Gandhinagar, IND
| | - Jinsa A Yohannan
- Department of Prosthodontics, Crown and Bridge, Karnavati School of Dentistry, Gandhinagar, IND
| | - Vidhi J Joshi
- Department of Paediatric and Preventive Dentistry, Karnavati School of Dentistry, Gandhinagar, IND
| |
Collapse
|
13
|
Zheng M, Ma X, Tan J, Zhao H, Yang Y, Ye X, Liu M, Li H. Enhancement of Biocompatibility of High-Transparency Zirconia Abutments with Human Gingival Fibroblasts via Cold Atmospheric Plasma Treatment: An In Vitro Study. J Funct Biomater 2024; 15:200. [PMID: 39057321 PMCID: PMC11277629 DOI: 10.3390/jfb15070200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2024] [Revised: 07/10/2024] [Accepted: 07/19/2024] [Indexed: 07/28/2024] Open
Abstract
The objective of this study was to explore the effects of cold atmospheric plasma (CAP) treatment on the biological behavior of human gingival fibroblasts (HGFs) cultured on the surface of high-transparency zirconia. Two types of zirconia, 3Y-ZTP and 4Y-PSZ, were subjected to a CAP treatment for various treatment durations. Analyses of the physical and chemical properties of 3Y-ZTP and 4Y-PSZ were conducted using scanning electron microscopy, contact angle measurements, and X-ray photoelectron spectroscopy, both before and after CAP treatment. The biological responses of HGFs on both surfaces were assessed using CCK-8 assay, confocal laser scanning microscopy, and real-time PCR. Initially, the oxygen and hydroxyl contents on the surface of 4Y-PSZ exceeded those on 3Y-ZTP. CAP treatment enhanced the surface hydrophilicity and the reactive oxygen species (ROS) content of 4Y-PSZ, while not altering the surface morphology. After CAP treatment, HGFs' adhesion on 4Y-PSZ was superior, with more pronounced effects compared to 3Y-ZTP. Notably, HGFs counts and the expression of adhesion-related genes on 4Y-PSZ peaked following the CAP exposures for 30 s and 60 s. Consequently, this study demonstrates that, following identical CAP treatments, 4Y-PSZ is more effective in promoting HGFs adhesion compared to traditional 3Y-ZTP zirconia.
Collapse
Affiliation(s)
- Miao Zheng
- Department of Stomatology, Peking University Third Hospital, Beijing 100191, China; (M.Z.); (X.M.)
| | - Xinrong Ma
- Department of Stomatology, Peking University Third Hospital, Beijing 100191, China; (M.Z.); (X.M.)
| | - Jianguo Tan
- Department of Prosthodontics, Peking University School and Hospital of Stomatology and National Center for Stomatology and National Clinical Research Center for Oral Diseases and National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, China; (J.T.); (Y.Y.); (X.Y.)
| | - Hengxin Zhao
- Department of Engineering Physics, Tsinghua University, Beijing 100084, China;
| | - Yang Yang
- Department of Prosthodontics, Peking University School and Hospital of Stomatology and National Center for Stomatology and National Clinical Research Center for Oral Diseases and National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, China; (J.T.); (Y.Y.); (X.Y.)
| | - Xinyi Ye
- Department of Prosthodontics, Peking University School and Hospital of Stomatology and National Center for Stomatology and National Clinical Research Center for Oral Diseases and National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, China; (J.T.); (Y.Y.); (X.Y.)
| | - Mingyue Liu
- First Clinical Division, Peking University School and Hospital of Stomatology, Beijing 100034, China
| | - Heping Li
- Department of Engineering Physics, Tsinghua University, Beijing 100084, China;
| |
Collapse
|
14
|
Pandey N, Karlin S, Bornstein MM, Rohr N. An Approach to Improve Specimen Processing for the Flexural Strength Testing of Zirconia. MATERIALS (BASEL, SWITZERLAND) 2024; 17:3479. [PMID: 39063771 PMCID: PMC11278445 DOI: 10.3390/ma17143479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Revised: 07/03/2024] [Accepted: 07/12/2024] [Indexed: 07/28/2024]
Abstract
Measuring the flexural strength of restorative materials such as zirconia is crucial for providing proper indications for clinical applications and predicting performance. Great variations in specimen preparation for flexural strength measurements exist among laboratories. The aim was to evaluate how the processing method, surface treatment, and test method of the specimens affect the flexural strength of zirconia. Zirconia specimens (VITA YZ HT) (n = 270) were processed using CAD/CAM or were conventionally milled with three different surface treatments (machined, ground, polished) and were measured with three-point bending (non-chamfered/chamfered) or biaxial flexural strength test. Weibull statistics were conducted. The mean flexural strength values ranged from 612 MPa (conventional, machined, three-point bending non-chamfered) to 1143 MPa (CAD/CAM, polished, biaxial flexural strength). The highest reliability is achieved when specimens are prepared using thoroughly controllable processing with CAD/CAM and subsequently polished. Higher strength values are achieved with the biaxial flexural strength test method because the stress concentration in relation to the effective volume is smaller. Polishing reduces surface microcracks and therefore increases the strength values.
Collapse
Affiliation(s)
- Nashib Pandey
- Biomaterials and Technology, Department Research, University Center for Dental Medicine Basel UZB, University of Basel, 4058 Basel, Switzerland
- Department of Periodontics & Oral Implantology, College of Medical Sciences, Bharatpur 44207, Nepal
| | - Sabrina Karlin
- Biomaterials and Technology, Department Research, University Center for Dental Medicine Basel UZB, University of Basel, 4058 Basel, Switzerland
| | - Michael Marc Bornstein
- Department of Oral Health & Medicine, University Center for Dental Medicine Basel UZB, University of Basel, 4058 Basel, Switzerland
| | - Nadja Rohr
- Biomaterials and Technology, Department Research, University Center for Dental Medicine Basel UZB, University of Basel, 4058 Basel, Switzerland
| |
Collapse
|
15
|
Munshi NM, Alsufayri M, Alzahrani A, Jurado CA, Hajjaj MS, Altassan M, Alzahrani SJ. Fracture Resistance of Zirconia Surveyed Crowns With Digitally Designed and Hand-Modified Occlusal Rest Seats. Cureus 2024; 16:e64423. [PMID: 39135816 PMCID: PMC11318952 DOI: 10.7759/cureus.64423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/12/2024] [Indexed: 08/15/2024] Open
Abstract
Background In light of the trend of using zirconia crowns, clinicians will likely face abutment included in removable partial dentures (RPD) designs with existing zirconia. However, the decision to replace the existing crown with a surveyed crown or modify the existing crown to accept the RPD is unclear. To the best of our knowledge, there is a lack of literature on the effect of preparing a rest seat on the existing monolithic zirconia crown in the patient's mouth on the fracture resistance of the crown. Therefore, in this study, we aimed to evaluate the fracture resistance of computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia surveyed crowns with digitally designed rest seats and hand-modified rest seats. Methods Thirty CAD/CAM zirconia surveyed crowns were digitally designed and fabricated and divided into groups (n=10 per group) as follows: Group 1 comprised surveyed crowns with no occlusal rest seat; Group 2 comprised surveyed crowns with a digitally designed mesial rest seat; and Group 3 comprised surveyed crowns with a hand-modified mesial rest seat. Then, with all the crowns cemented to metal dies, the specimens were subjected to a fracture resistance test using a universal testing machine (Model 8501 Instron, Norwood, MA, USA). Results Surveyed crowns without any rest seat and those with digitally created and hand-modified rest seats displayed different fracture resistances: crowns with no rest seat offered the highest fracture resistance (5831 ± 895.15 N), followed by those with a digitally designed and milled rest seat (5280 ± 1673.33 N). Crowns with a hand-modified rest seat provided the lowest fracture resistance (4976 ± 322.5 N). Based on our results, surveyed crowns without a rest seat displayed higher fracture resistance than those with a rest seat. Conclusion The fracture resistance of crowns with a digitally designed and milled rest seat was statistically similar to that of control crowns with no rest seat, whereas hand-modified rest seats significantly reduced the fracture resistance of surveyed zirconia crowns.
Collapse
Affiliation(s)
- Nabeel M Munshi
- Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, SAU
| | | | - Adham Alzahrani
- Department of General Dentistry, King Abdulaziz University, Jeddah, SAU
| | - Carlos A Jurado
- Department of General Dentistry, College of Dentistry, University of Tennessee Health Science Center, Memphis, USA
| | - Maher S Hajjaj
- Department of Restorative Dentistry, King Abdulaziz University, Jeddah, SAU
| | - Mosa Altassan
- Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, SAU
| | - Saeed J Alzahrani
- Department of Restorative Dentistry, King Abdulaziz University, Jeddah, SAU
| |
Collapse
|
16
|
Işisağ Ö, Pektaş N. Comparison of the fracture strengths of single-unit metal-ceramic and monolithic zirconium restorations in the molar region: a systematic review and meta-analysis. Odontology 2024; 112:751-760. [PMID: 38103151 DOI: 10.1007/s10266-023-00878-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Accepted: 11/17/2023] [Indexed: 12/17/2023]
Abstract
Despite the success of monolithic zirconia restorations (MZ), metal-ceramic restorations (MC) are still considered the gold standard for fixed prosthetics in the posterior region. This systematic review and meta-analysis aimed to compare the fracture strengths of single-unit MC and MZ in the molar region. This review was based on the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA, 2020) statement. All articles were searched from the PubMed and Web of Science databases until November 18, 2022. All in vitro studies evaluating the fracture strengths of MC and MZ were also included. Statistical analysis was performed with the Comprehensive Meta-Analysis program, with a significance level of 0.05. Out of 753 studies, five were selected. The fracture strengths of MZ and MC did not show any statistically significant difference for both tooth (95% CI - 1.589: 2.118, p = 0.779, z = 0.280) and implant (95% CI - 2.215: 2.191, p = 0.992 z = - 0.010) supported restorations. However, different abutment materials (p < 0.001) and aging treatments (p < 0.001) in tooth-supported restorations displayed a significant statistical difference. Additionally, a significant difference was also observed in subgroup analysis considering different cements (p = 0.001) and load speeds (p = 0.001) in implant-supported restorations. Fracture strengths of MZ and MC did not show a significant statistical difference in implant or tooth-supported single-unit posterior restorations. MZ may be a suitable alternative to MC in single-unit posterior restorations. The results should be interpreted with caution, as the included studies were in vitro.
Collapse
Affiliation(s)
- Özer Işisağ
- Department of Prosthodontics, Faculty of Dentistry, Afyonkarahisar Health Sciences University, Inonu Boulevard No: 4, Afyonkarahisar, Turkey.
| | - Nur Pektaş
- Department of Prosthodontics, Faculty of Dentistry, Afyonkarahisar Health Sciences University, Inonu Boulevard No: 4, Afyonkarahisar, Turkey
| |
Collapse
|
17
|
Alqutaibi AY, Alghauli MA, Dewedar K, AbdElaziz MH, Saker S. The influence of Zircos-E® etchant, silica coating, and alumina air-particle abrasion on the debonding resistance of endocrowns with three different preparation designs. Clin Exp Dent Res 2024; 10:e901. [PMID: 38770577 PMCID: PMC11106642 DOI: 10.1002/cre2.901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Revised: 04/25/2024] [Accepted: 05/06/2024] [Indexed: 05/22/2024] Open
Abstract
OBJECTIVES The study aimed to evaluate the debonding resistance of three different endocrown designs on molar teeth, using three different zirconia surface pretreatments. MATERIAL AND METHOD Ninety human mandibular first molars were divided into three main groups: endocrowns without ferrule, with 1 mm ferrule, and with 2 mm ferrule. The subgroups were defined by their surface pretreatment method used (n = 15): 50 μm alumina air-particle abrasion, silica coating using 30 μm Cojet™ particles, and Zircos-E® etching. The endocrowns were fabricated using multilayer zirconia ceramic, cemented with self-adhesive resin cement, and subjected to 5000 thermocycles (5-55°C) before debonding. The data obtained were analyzed using a two-way ANOVA. RESULTS All test specimens survived the thermocyclic aging. The results indicated that both the preparation design and the surface treatment had a significant impact on the resistance to debonding of the endocrowns (p < .001). The 2 mm ferrule followed by the 1 mm ferrule designs exhibited the highest debonding resistance, both were superior to the endocrown without ferrule. Zircos-E® etching and silica coating yielded comparable debonding resistance, which were significantly higher than alumina air-particle abrasion. All endocrowns demonstrated a favorable failure mode. CONCLUSIONS All designs and surface treatments showed high debonding resistance for a single restoration. However, ferrule designs with Zircos-E® etching or silica coating may represent better clinical options compared to the nonferrule design or alumina airborne-particle abrasion. Nonetheless, further research, including fatigue testing and evaluations with different luting agents is recommended.
Collapse
Affiliation(s)
- Ahmed Yaseen Alqutaibi
- Substitutive Dental Science Department, College of DentistryTaibah UniversityAl‐MadinahSaudi Arabia
- Department of Prosthodontics, Faculty of DentistryIbb UniversityIbbYemen
| | | | - Karim Dewedar
- Crown and Bridge Department, Faculty of Dental MedicineAl‐Azhar UniversityCairoEgypt
| | - Mohammed H. AbdElaziz
- Substitutive Dental Science Department, College of DentistryTaibah UniversityAl‐MadinahSaudi Arabia
- Crown and Bridge Department, Faculty of Dental MedicineAl‐Azhar UniversityCairoEgypt
| | - Samah Saker
- Fixed Prosthodontic Department, Faculty of DentistryMansoura UniversityMansouraEgypt
| |
Collapse
|
18
|
Mosaddad SA, Peláez J, Panadero RA, Ghodsi S, Akhlaghian M, Suárez MJ. Do 3D-printed and milled tooth-supported complete monolithic zirconia crowns differ in accuracy and fit? A systematic review and meta-analysis of in vitro studies. J Prosthet Dent 2024:S0022-3913(24)00283-X. [PMID: 38772783 DOI: 10.1016/j.prosdent.2024.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 04/03/2024] [Accepted: 04/04/2024] [Indexed: 05/23/2024]
Abstract
STATEMENT OF PROBLEM Additive (3-dimensional printing) and subtractive (milling) methods are digital approaches to fabricating zirconia restorations. Comparisons of their resultant fabrication accuracy and restoration fit are lacking. PURPOSE The purpose of this systematic review and meta-analysis was to evaluate the accuracy and fit of monolithic zirconia crowns fabricated by 3-dimensional printing and milling. MATERIAL AND METHODS The PubMed (Medline), Scopus, Embase, Web of Science, Cochrane Library, and Google Scholar databases were searched up to August 2023. Eligible records were included, and the standardized mean difference (SMD) analyzed 4 outcomes: marginal fit, intaglio fit, trueness, and precision. Publication bias was analyzed with Trim-and-fill, the Egger regression test, and Begg funnel plot. Methodological quality was rated using the QUIN tool. RESULTS A total of 15 publications were found eligible out of the initial 6539 records. The 3-dimensional printing group demonstrated a lower marginal fit (SMD=1.46, 95% CI=[0.67, 2.26], P<.001; I2=83%, P<.001) and trueness (SMD=0.69, 95% CI=[0.20, 1.18], P=.006; I2=88%, P<.001) and a significantly higher precision (SMD=-2.19, 95% CI=[-2.90, -1.48], P<.001; I2=56%, P=.045). The intaglio fit did not differ significantly across the study groups (SMD=0.77, 95% CI=[-0.22, 1.77], P=.127; I2=87%, P<.001). CONCLUSIONS Given the high degree of heterogeneity, it can be cautiously concluded that while 3-dimensional printing led to greater precision, the outcomes of the 2 accuracy and adaptation parameters most crucial to the longevity of the restorations-trueness and marginal fit-showed the superiority of the milling technique.
Collapse
Affiliation(s)
- Seyed Ali Mosaddad
- Researcher, Department of Conservative Dentistry and Bucofacial Prosthesis, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain; and Adjunct Faculty Member, Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India.
| | - Jesús Peláez
- Adjunct Professor, Department of Conservative Dentistry and Bucofacial Prosthesis, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain.
| | - Rubén Agustín Panadero
- Professor, Department of Stomatology, Faculty of Medicine and Dentistry, Valencia University, Valencia, Spain
| | - Safoura Ghodsi
- Associate Professor, Dental Research Center, Dentistry Research Institute, Department of Prosthodontics, Tehran University of Medical Sciences, Tehran, Iran
| | - Marzieh Akhlaghian
- Assistant Professor, Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - María J Suárez
- Professor, Department of Conservative Dentistry and Bucofacial Prosthesis, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain
| |
Collapse
|
19
|
Puengpaiboon U, Rattanapan N, Pasam VK, Sukjamsri C. Finite Element Analysis of Anterior Implant-Supported Restorations with Different CAD-CAM Restorative Materials. Eur J Dent 2024. [PMID: 38744334 DOI: 10.1055/s-0044-1785532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024] Open
Abstract
OBJECTIVES Due to the lack of literature concerning the selection of crown materials for the restoration of anterior teeth, this study aimed to investigate the effects of six distinct computer-aided design and computer-aided manufacturing (CAD-CAM) crown materials on stress and strain distribution within implant-supported maxillary central incisor restorations, employing finite element analysis (FEA). Furthermore, a comparative analysis was conducted between models that incorporated adjacent natural teeth and those that did not, intending to guide the selection of the most suitable modeling approach. MATERIALS AND METHODS Crown materials, including Lava Ultimate, Enamic, Emax CAD, Suprinity, Celtra Duo, and Cercon xt ML, were the subjects of the investigation. FEA models incorporating Coulomb friction were developed. These models were subjected to an oblique load, simulating the average maximum bite force experienced by anterior teeth. The potential for failure in titanium implant components and the prosthesis crown was evaluated through von Mises and principal stress, respectively. Furthermore, the failure of crestal bone was assessed through principal strain values. STATISTICAL ANALYSIS Stress values for each implant component and strain values of the bone were extracted from the models. To assess the impact of the six groups of crown materials, Kruskal-Wallis analysis of variance and post-hoc comparisons were conducted. Additionally, a statistical comparison between the two groups with Lava Ultimate and Cercon xt ML was performed using the Mann-Whitney U test to determine the difference in the two modeling approaches. RESULTS Higher crown material stiffness led to decreased stress in the abutment, fixture, and retaining screw, along with reduced strain in the surrounding bone. However, the decrease in stress and strain values became less significant with increasing crown stiffness. Additionally, the model with adjacent teeth showed significantly lower stress and strain concentrations compared to the model without adjacent teeth. CONCLUSION Crowns with a high elastic modulus were the optimal choice for anterior teeth restoration. Constructing FEA models with adjacent teeth was highly recommended to gain a deeper understanding of the mechanical behavior of dental implant restorations.
Collapse
Affiliation(s)
- Usanee Puengpaiboon
- Department of General Dentistry, Faculty of Dentistry, Srinakharinwirot University, Bangkok, Thailand
| | - Nichapat Rattanapan
- Department of Biomedical Engineering, Faculty of Engineering, Srinakharinwirot University, Nakhon Nayok, Thailand
| | - Vamsi Krishna Pasam
- Department of Mechanical Engineering, National Institute of Technology Warangal, Warangal, Telangana, India
| | - Chamaiporn Sukjamsri
- Department of Biomedical Engineering, Faculty of Engineering, Srinakharinwirot University, Nakhon Nayok, Thailand
| |
Collapse
|
20
|
Alghauli M, Alqutaibi AY, Wille S, Kern M. 3D-printed versus conventionally milled zirconia for dental clinical applications: Trueness, precision, accuracy, biological and esthetic aspects. J Dent 2024; 144:104925. [PMID: 38471580 DOI: 10.1016/j.jdent.2024.104925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 02/11/2024] [Accepted: 03/04/2024] [Indexed: 03/14/2024] Open
Abstract
OBJECTIVES This systematic review aimed to compare the clinical outcome, internal gap, trueness, precision, and biocompatibility of 3D-printed (AM) compared to milled (SM) zirconia restorations. DATA SOURCE A thorough search of Internet databases was conducted up to September 2023. The search retrieved studies compared AM zirconia to SM zirconia restorations regarding clinical outcome, fit, trueness, precision, and biocompatibility. STUDY SELECTION Of 1736 records, only 59 were screened for eligibility, and 22 records were included in this review. The quality of studies was assessed using the revised Cochrane risk-of-bias tool (ROB2), and the Modified Consort Statement. One clinical study exhibited a low risk of bias. All laboratory studies revealed some bias concerns. Short-term observation showed 100 % survival with no signs of periodontal complications. 3D-printed zirconia crowns showed statistically significant lower ΔE and a better match to adjacent teeth (p ≤ 0.5). The fit, trueness, and precision vary with the printing technique and the tooth surface. CONCLUSIONS 3D-printed zirconia crowns provide better aesthetic color and contour match to adjacent natural teeth than milled crowns. Both 3D printing and milling result in crowns within the clinically acceptable internal and marginal fit. Except for nanoparticle jetting, the marginal gap of SM crowns was smaller than AM crowns, however, both were clinically acceptable. Laminate veneers might be more accurately produced by 3D printing. 3D-printed axial surface trueness was better than milled axial surfaces. Long-term RCTs are recommended to confirm the clinical applicability of 3D-printed restorations. CLINICAL SIGNIFICANCE Internal fit and gap, precision, and trueness are fundamental requirements for successful dental restorations. Both techniques produce restorations with clinically acceptable marginal and internal fit. Axial surfaces and narrow or constricted areas favored 3D-printed than conventionally milled zirconia.
Collapse
Affiliation(s)
- Mohammed Alghauli
- Prosthodontics Department, College of Dentistry, Ibb University, Yemen; Department of Prosthodontic, Propaedeutic and Dental Materials, Faculty of Dentistry, Kiel University, Kiel, Germany.
| | - Ahmed Yaseen Alqutaibi
- Prosthodontics Department, College of Dentistry, Ibb University, Yemen; Prosthodontics Department, College of Dentistry, Taibah University, Al-Madinah, Saudi Arabia
| | - Sebastian Wille
- Department of Prosthodontic, Propaedeutic and Dental Materials, Faculty of Dentistry, Kiel University, Kiel, Germany
| | - Matthias Kern
- Department of Prosthodontic, Propaedeutic and Dental Materials, Faculty of Dentistry, Kiel University, Kiel, Germany
| |
Collapse
|
21
|
Branco AC, Santos T, Bessa LJ, Barahona I, Polido M, Colaço R, Serro AP, Figueiredo-Pina CG. Optimized 3D printed zirconia-reinforced leucite with antibacterial coating for dental applications. Dent Mater 2024; 40:629-642. [PMID: 38369404 DOI: 10.1016/j.dental.2024.02.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 01/17/2024] [Accepted: 02/12/2024] [Indexed: 02/20/2024]
Abstract
OBJECTIVES This study aims to produce by robocasting leucite/zirconia pieces with suitable mechanical and tribological performance, convenient aesthetics, and antibacterial properties to be used in dental crown replacement. METHODS Leucite pastes reinforced with 12.5%, 25%, and 37.5% wt. ZrO2 nanoparticles were prepared and used to print samples that after sintering were characterized in terms of density, shrinkage, morphology, porosity, mechanical and tribological properties and translucency. A coating of silver diamine fluoride (SDF) and potassium iodide (KI) was applied over the most promising material. The material's antibacterial activity and cytotoxicity were assessed. RESULTS It was found that the increase of ZrO2 reinforcement up to 25% enhanced both microhardness and fracture toughness of the sintered composite. However, for a superior content of ZrO2, the increase of the porosity negatively affected the mechanical behaviour of the composite. Moreover, the composite with 25% ZrO2 exhibited neglectable wear in chewing simulator tests and induced the lowest wear on the antagonist dental cusps. Although this composite exhibited lower translucency than human teeth, it was three times higher than the ZrO2 glazed material. Coating this composite material with SDF+KI conferred antibacterial properties without inducing cytotoxicity. SIGNIFICANCE Robocasting of leucite reinforced with 25% ZrO2 led to best results. The obtained material revealed superior optical properties and tribomechanical behaviour compared to glazed ZrO2 (that is a common option in dental practice). Moreover, the application of SDF+KI coating impaired S. aureus proliferation, which anticipates its potential benefit for preventing pathogenic bacterial complications associated with prosthetic crown placement.
Collapse
Affiliation(s)
- A C Branco
- CQE, Centro de Química Estrutural, Institute of Molecular Sciences, Departamento de Engenharia Química, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal; CDP2T, Centro de Desenvolvimento de Produto e Transferência de Tecnologia, Escola Superior de Tecnologia de Setúbal, Instituto Politécnico de Setúbal, Setúbal, Portugal; CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal
| | | | - L J Bessa
- CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal
| | - I Barahona
- CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal
| | - M Polido
- CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal
| | - R Colaço
- IDMEC e Departamento de Engenharia Mecânica, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - A P Serro
- CQE, Centro de Química Estrutural, Institute of Molecular Sciences, Departamento de Engenharia Química, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal; CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal.
| | - C G Figueiredo-Pina
- CDP2T, Centro de Desenvolvimento de Produto e Transferência de Tecnologia, Escola Superior de Tecnologia de Setúbal, Instituto Politécnico de Setúbal, Setúbal, Portugal; CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal; CeFEMA, Centro de Física e Engenharia de Materiais Avançados, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| |
Collapse
|
22
|
Alarcón-Sánchez MA, Castro-Alarcón N, Sandoval-Guevara D, Vázquez-Villamar M, Fernández-Acosta K, Méndez-Gómez MY, Parra-Rojas I, Romero-Castro NS. Analysis of subgingival microbiota and IL-1β, TNF-α and CX3CL1 levels in gingival crevicular fluid of fixed dental prostheses. Dent Mater J 2024; 43:235-246. [PMID: 38417861 DOI: 10.4012/dmj.2023-136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/01/2024]
Abstract
Prosthetic biomaterials can affect the composition of the subgingival microbiota and consequently the production of proinflammatory cytokines, causing damage to the periodontium. A total of 40 patients were divided into two groups: 20 with monolithic zirconia (MZ) prostheses and 20 with porcelain fused to metal (PFM) with nickel-chromium (Ni-Cr) alloy prostheses. Subgingival plaque and gingival crevicular fluid samples were taken. The Checkerboard technique for DNA-DNA hybridization and the enzyme-linked immunosorbent assay technique were performed. Teeth with MZ presented a lower percentage of bleeding on probing and tooth mobility compared to teeth with PFM with Ni-Cr alloy. Prosthodontic teeth harbored higher total levels of the 18 bacterial species than non-prosthodontic teeth. There was a higher prevalence of S. gordonii and V. parvula species in PFM with Ni-Cr alloy compared to MZ. There was an increase in IL-1β, TNF-α and CX3CL1 levels in PFM with Ni-Cr alloy compared to MZ. MZ is a candidate biomaterial with fewer negative effects on the periodontium, allowing for longer prostheses longevity in the mouth.
Collapse
Affiliation(s)
| | - Natividad Castro-Alarcón
- Department of Microbiology, Faculty of Chemical-Biological Sciences, Autonomous University of Guerrero
| | - Daniel Sandoval-Guevara
- Department of Implantology and Oral Rehabilitation, Faculty of Dentistry, Autonomous University of Guerrero
| | - Mirna Vázquez-Villamar
- Agricultural Microbiology Laboratory, Faculty of Agricultural and Environmental Science, Autonomous University of Guerrero
| | - Karla Fernández-Acosta
- Department of Implantology and Oral Rehabilitation, Faculty of Dentistry, Autonomous University of Guerrero
| | - Mayra Yanet Méndez-Gómez
- Department of Implantology and Oral Rehabilitation, Faculty of Dentistry, Autonomous University of Guerrero
| | - Isela Parra-Rojas
- Obesity and Diabetes Research Laboratory, Faculty of Chemical-Biological Sciences, Autonomous University of Guerrero
| | | |
Collapse
|
23
|
Farghal A, Dewedar K, AbdElaziz MH, Saker S, Hassona M, Algabri R, Alqutaibi AY. Effect of ceramic materials and tooth preparation design on computer-aided design and computer-aided manufacturing endocrown adaptation and retentive strength: An in vitro study. Clin Exp Dent Res 2024; 10:e843. [PMID: 38345492 PMCID: PMC10828905 DOI: 10.1002/cre2.843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 11/23/2023] [Accepted: 01/04/2024] [Indexed: 02/15/2024] Open
Abstract
OBJECTIVES To evaluate how various tooth preparation designs impact the adaptation-both at the margins and internally-and the retentive strength of computer-aided design and computer-aided manufacturing (CAD/CAM) produced endocrowns. MATERIALS AND METHODS 60 extracted human mandibular first molars were endodontically treated and assigned into three groups (n = 20) according to the tooth preparation design: Group N: butt joint design, Group F and F1 received 1- and 2-mm circumferential ferrule preparation, respectively. Endocrowns were milled using either lithium disilicate glass-ceramic (IPS emax ceramic) or monolithic zirconia. The internal and marginal adaptation of the endocrowns were evaluated using the replica technique. After cementation, the endocrowns of all test groups were dislodged axially at 0.5 mm/min using a universal testing machine. A 2-way ANOVA and the independent samples t-test (α = .05) were performed to statistically analyze the data. RESULTS The effect of changing the design of the tooth preparation (butt joint, ferrule) on the marginal and internal gap was shown to be statistically significant (p < .05); the lower gap values were recorded at the axial followed by cervical, marginal, and pulpal floor walls in both ceramic groups regardless of the teeth preparation design. The ANOVA test revealed similar average removal forces and stresses for the two types of tested ceramic materials. CONCLUSION IPS emax ceramic adapted better than monolithic zirconia ceramic, regardless of the preparation design. Ferrule preparation design is more retentive than butt joint preparation, regardless of the type of ceramic material used.
Collapse
Affiliation(s)
- Ahmed Farghal
- Substitutive Dental Science, College of DentistryTaibah UniversityMadinahSaudi Arabia
| | - Karim Dewedar
- Crown and Bridge Department, Faculty of Dental MedicineAl‐Azhar UniversityCairoEgypt
| | - Mohammed H. AbdElaziz
- Substitutive Dental Science, College of DentistryTaibah UniversityMadinahSaudi Arabia
- Crown and Bridge Department, Faculty of Dental MedicineAl‐Azhar UniversityCairoEgypt
| | - Samah Saker
- Fixed Prosthodontics, Faculty of DentistryMansoura UniversityMansouraEgypt
| | - Mahy Hassona
- Fixed Prosthodontics, Faculty of DentistryMansoura UniversityMansouraEgypt
| | - Radwan Algabri
- Prosthodontic Department, Faculty of DentistryIbb UniversityIbbYemen
- Prosthodontic Department, Faculty of DentistryNational University, Ibb branchIbbYemen
| | - Ahmed Yaseen Alqutaibi
- Substitutive Dental Science, College of DentistryTaibah UniversityMadinahSaudi Arabia
- Prosthodontic Department, Faculty of DentistryIbb UniversityIbbYemen
| |
Collapse
|
24
|
Yigit BS, Al-Akkad M, Mounajjed R. Zirconia Ceramics. ACTA MEDICA (HRADEC KRALOVE) 2024; 67:39-45. [PMID: 39434669 DOI: 10.14712/18059694.2024.18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2024]
Abstract
Zirconia ceramics have become popular among other dental ceramics thanks to their biological, mechanical, optical, and aesthetic properties. CAD/CAM (computer-aided design/ computer-aided manufacturing) technology improvement has played a vital role in the increased popularity of zirconia ceramics; easy computer manipulation significantly expanded the possibility of using different types of restorations. Zirconia ceramics have a broad spectrum of indications in prosthetic dentistry, from simple restorations to complex structures supported by dental implants. A good orientation in the classification, features, and manipulation of zirconia ceramics is the main key to success.
Collapse
Affiliation(s)
- Bedirhan Savas Yigit
- Institute of Dentistry and Oral Sciences, Palacky University Olomouc, Olomouc, Czech Republic
| | - Marwan Al-Akkad
- Institute of Dentistry and Oral Sciences, Palacky University Olomouc, Olomouc, Czech Republic
| | - Radek Mounajjed
- Institute of Dentistry and Oral Sciences, Palacky University Olomouc, Olomouc, Czech Republic.
- Private Clinician, DCM Clinic, Hradec Králové, Czech Republic.
| |
Collapse
|
25
|
Liang Y, Leng Y, Zhang J. Influence of clinical zirconia surface treatments on microscopic characteristics and adhesion-proliferation behavior of human gingival fibroblasts. JOURNAL OF STOMATOLOGY, ORAL AND MAXILLOFACIAL SURGERY 2023; 124:101564. [PMID: 37453567 DOI: 10.1016/j.jormas.2023.101564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Revised: 07/10/2023] [Accepted: 07/12/2023] [Indexed: 07/18/2023]
Abstract
Zirconia is favored in dental implant applications due to its biocompatibility, mechanical properties, and esthetic appeal, particularly in its interaction with soft oral tissues such as the gingiva. To optimize zirconia for clinical use, surface treatments like sanding and polishing are essential. The aim of this study was to investigate the effects of clinical surface treatments on the microscopic characteristics of zirconia and the adhesion and proliferation of human gingival fibroblasts (HGFs). Scanning electron microscopy (SEM) and fluorescence microscopy were utilized to examine the microscopic morphology and roughness resulting from various clinical surface treatment procedures on zirconia and to assess their impact on the microscopic appearance and behavior of HGFs. The results showed that the application of surface treatment procedures, particularly polishing treatments, resulted in the formation of a regular shallow groove morphology and a significant reduction in roughness in zirconia. This was accompanied by improved cell proliferation, cell adhesion, and the expression of integrin β1 in HGFs. The results suggest that smoother zirconia surfaces promote better cell-material interactions, potentially improving the clinical success of dental implants. This research contributes to our understanding of the optimal surface roughness for soft tissue adhesion and the effect of different micro-morphologies on HGF attachment.
Collapse
Affiliation(s)
- Yajing Liang
- School of Stomatology, Capital Medical University, Beijing, PR China
| | - Yanjun Leng
- School of Stomatology, Central South University, Changsha, PR China
| | - Jiebing Zhang
- School of Stomatology, Capital Medical University, Beijing, PR China.
| |
Collapse
|
26
|
Du Q, Cui T, Niu G, Qui J, Yang B. Improving Bond Strength of Translucent Zirconia Through Surface Treatment With SiO2-ZrO2 Coatings. Oper Dent 2023; 48:666-676. [PMID: 37961015 DOI: 10.2341/22-121-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/13/2023] [Indexed: 11/15/2023]
Abstract
BACKGROUND Translucent monolithic zirconia ceramics have been applied in dental clinics due to their esthetic translucent formulations and mechanical properties. Considering inherent ceramic brittleness, adhesive bonding with resin composite increases the fracture resistance of ceramic restorations. However, zirconia is a chemically stable material that is difficult to adhesively bond with resin. OBJECTIVES To investigate the influences of SiO2-ZrO2 coatings on adhesive bonding of zirconia and the surface characterization of those coatings. METHODS AND MATERIALS Translucent zirconia discs were classified into groups based on surface treatments: CT (control), SB (sandblasting), C21(SiO2:ZrO2=2:1), C11(SiO2:ZrO2=1:1), and C12 (SiO2:ZrO2=1:2) (n=10). Surface characterization of coatings on zirconia were analyzed by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), surface roughness assessment (Ra), X-ray diffraction (XRD), water contact angle (WCA), translucency parameter (TP), and shear bond strength (SBS). Two-way ANOVA for shear bond strength results and ANOVA for Ra and WCA were performed. RESULTS SEM images revealed SiO2 islands on zirconia disks coated with SiO2-ZrO2. Surface roughness of C12, C11, and C21 groups was significantly larger than those of groups SB and CT (p<0.05). XRD results showed that phase transformation of zirconia disks was detected only in the SB group. In addition, SiO2-ZrO2 coatings reduced WCA. The translucency decreased only in group C21. Group C11 showed the highest shear bond strength under both aging conditions. CONCLUSION SiO2-ZrO2 coating is a promising method to enhance the adhesive resin bonding of translucent zirconia without causing phase transformation of translucent zirconia.
Collapse
Affiliation(s)
- Q Du
- †Qiao Du, DDS, Department of Stomatology, Beijing Integrated Traditional Chinese and Western Medicine Hospital, Beijing, China
| | - T Cui
- †Tiehan Cui, DDS, Department of Oral and Maxillofacial Surgery, The First Affiliated Hospital of Nanchang University, Nanchang, China
| | - G Niu
- *Guangliang Niu, DDS, Department of Stomatology,Beijing Integrated Traditional Chinese and Western Medicine Hospital, Beijing, China
| | - J Qui
- *Jiaxuan Qui, DDS, Department of Oral and Maxillofacial Surgery, The First Affiliated Hospital of Nanchang University, Nanchang, China
| | - B Yang
- *Bin Yang, DDS, Restorative Department, College of Dentistry, University of Illinois at Chicago, IL, USA
| |
Collapse
|
27
|
Karimi M, Hashemikamangar SS, Farahani S. Veneer crowns in anterior endodontically-treated teeth: A case report with 1-year follow-up. Clin Case Rep 2023; 11:e8084. [PMID: 37908785 PMCID: PMC10613717 DOI: 10.1002/ccr3.8084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 09/01/2023] [Accepted: 10/01/2023] [Indexed: 11/02/2023] Open
Abstract
Key Clinical Message Veneer crowns can be used in anterior endodontically-treated teeth with light occlusal force and enamel substrate consideration as a more conservative approach instead of conventional all ceramic crowns. Abstract All-ceramic anterior crowns and veneers have been used widely in dentistry with high clinical success rate. The development of new reinforced ceramics in recent years has led to more use of extended defect-oriented preparation designs, that is, extended veneers, instead of full crown preparations which are less invasive. A veneer crown is simply a veneer that covers the entire tooth. The preparation preserves remaining enamel and uses a conservative preparation design. Its indication should be carefully raised taking into consideration various factors. The preparation design is crucial to ensure longevity of such restoration. The balance is between sufficient preparation for the material thickness and adequate strength against occlusal load and the enamel preservation. A 24-year-old man referred to the restorative department of the Dentistry School of Tehran University of Medical Sciences complaining from his poor esthetics in the maxillary incisors. In clinical and radiographic evaluation, he had open bite, composite discoloration due to corrosion of the pre-fabricated posts in all four incisors, a periapical lesion in tooth 21 and under-filled root canal therapy in tooth 22. All four posts and composite restorations were removed and teeth 21 and 22 were retreated. Although the amount of remaining tooth tissue was low, it had enough enamel thickness, especially in the buccal area. Taking into consideration this mixed enamel and dentin substrate, endodontics access, esthetics needs and canine guidance occlusion with no parafunction history, bonded lithium disilicate veneer crowns were selected to restore the maxillary incisors. A 12-month follow-up showed promising clinical (healthy gingival tissue and successful restorations) and radiographic (reduced periapical lesion) outcomes.
Collapse
Affiliation(s)
- Mandana Karimi
- Department of Restorative Dentistry, Dental SchoolTehran University of Medical SciencesTehranIran
| | | | - Shakiba Farahani
- Department of Restorative Dentistry, Dental SchoolTehran University of Medical SciencesTehranIran
| |
Collapse
|
28
|
Cagna DR, Donovan TE, McKee JR, Eichmiller F, Metz JE, Marzola R, Murphy KG, Troeltzsch M. Annual review of selected scientific literature: A report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2023; 130:453-532. [PMID: 37453884 DOI: 10.1016/j.prosdent.2023.06.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 06/02/2023] [Accepted: 06/05/2023] [Indexed: 07/18/2023]
Abstract
The Scientific Investigation Committee of the American Academy of Restorative Dentistry offers this review of the 2022 dental literature to briefly touch on several topics of interest to modern restorative dentistry. Each committee member brings discipline-specific expertise in their subject areas that include (in order of the appearance in this report): prosthodontics; periodontics, alveolar bone, and peri-implant tissues; dental materials and therapeutics; occlusion and temporomandibular disorders; sleep-related breathing disorders; oral medicine and oral and maxillofacial surgery; and dental caries and cariology. The authors focused their efforts on reporting information likely to influence the daily dental treatment decisions of the reader with an emphasis on innovations, new materials and processes, and future trends in dentistry. With the tremendous volume of literature published daily in dentistry and related disciplines, this review cannot be comprehensive. Instead, its purpose is to update interested readers and provide valuable resource material for those willing to subsequently pursue greater detail on their own. Our intent remains to assist colleagues in navigating the tremendous volume of newly minted information produced annually. Finally, we hope that readers find this work helpful in managing patients.
Collapse
Affiliation(s)
- David R Cagna
- Professor, Associate Dean, Chair, and Residency Director, Department of Prosthodontics, University of Tennessee Health Sciences Center College of Dentistry, Memphis, Tenn.
| | - Terence E Donovan
- Professor, Department of Comprehensive Oral Health, University of North Carolina School of Dentistry, Chapel Hill, NC
| | - James R McKee
- Private practice, Restorative Dentistry, Downers Grove, Ill
| | - Frederick Eichmiller
- Vice President and Science Officer (Emeritus), Delta Dental of Wisconsin, Stevens Point, Wis
| | - James E Metz
- Private practice, Restorative Dentistry, Columbus, Ohio
| | | | - Kevin G Murphy
- Associate Clinical Professor, Department of Periodontics, University of Maryland College of Dentistry, Baltimore, Md
| | - Matthias Troeltzsch
- Private practice, Oral, Maxillofacial, and Facial Plastic Surgery, Ansbach, Germany; Department of Oral and Maxillofacial Surgery and Facial Plastic Surgery, University Hospital, Ludwig Maximilian University of Munich (LMU), Munich, Germany
| |
Collapse
|
29
|
Altayyar S, Al‐zordk W, Algabri R, Rajah E, Al‐baadani A, Alqutaibi AY, Madina MA, Ghazy MH. Prospective evaluation of implants-supported, tooth-implant supported, and teeth-supported 3-unit posterior monolithic zirconia fixed restorations: Bite force and patient satisfaction. Clin Exp Dent Res 2023; 9:810-819. [PMID: 37703213 PMCID: PMC10582233 DOI: 10.1002/cre2.780] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 08/12/2023] [Accepted: 08/27/2023] [Indexed: 09/15/2023] Open
Abstract
OBJECTIVES This study aimed to evaluate the maximum bite force (MBF) and satisfaction of patients restored with implants, combined tooth-implants, and teeth-supported monolithic zirconia fixed dental prostheses (FDPs). MATERIALS AND METHODS Thirty partially edentulous patients in need of three units of FDPs in their mandibular posterior region were divided into three equal groups (n = 10) as follows: Group-1 patients received two implants for each at the second premolar and second molar regions, Group-2 patients received one implant for each at the second molar region, and Group-3 patients with missing lower first molar. All the restorations were constructed from monolithic zirconia. Patients were evaluated 1 week after placement of restorations (baseline) and then after 6, 12, and 24-month intervals for MBF using force transducer occlusal force meter and satisfaction (function, esthetic, and overall satisfaction) using a visual analog scale. RESULTS The mean MBF for Group 1 was higher than Group 2 (p = .044) but not that of Group 3 (p = .923). Additionally, Group 3 displayed a higher MBF than Group 2, although this difference was not statistically significant (p = .096). Concerning patient satisfaction, all study groups reported high levels of satisfaction across all satisfaction elements, and no significant differences were observed between the groups. CONCLUSION Within the limitations of this study, it can be concluded that Group 1 gives comparable anticipated treatment outcomes as Group 3 concerning biting force and patient satisfaction. However, Group 2 gives comparable satisfaction results with biting force value within the normal range; thus, it might be used as a treatment option in a specific situation.
Collapse
Affiliation(s)
- Sadeq Altayyar
- Prosthodontic Department, Faculty of DentistryIBB UniversityIbbYemen
| | - Walid Al‐zordk
- Fixed Prosthodontic Department, Faculty of DentistryMansoura UniversityMansouraEgypt
| | - Radwan Algabri
- Prosthodontic Department, Faculty of DentistryIBB UniversityIbbYemen
- Prosthodontic Department, National UniversityIbb‐BranchIbbYemen
| | - Eshraq Rajah
- Prosthodontic Department, Faculty of DentistrySana'a UniversitySana'aYemen
| | | | - Ahmed Yaseen Alqutaibi
- Department of Prosthodontic and Implant Dentistry, College of DentistryTaibah UniversityAl MadinahSaudi Arabia
- Department of Prosthodontics, College of DentistryIbb UniversityIbbYemen
| | - Manal Abo Madina
- Fixed Prosthodontic Department, Faculty of DentistryMansoura UniversityMansouraEgypt
| | - Mohammed H. Ghazy
- Fixed Prosthodontic Department, Faculty of DentistryMansoura UniversityMansouraEgypt
| |
Collapse
|
30
|
Kongkiatkamon S, Rokaya D, Kengtanyakich S, Peampring C. Current classification of zirconia in dentistry: an updated review. PeerJ 2023; 11:e15669. [PMID: 37465158 PMCID: PMC10351515 DOI: 10.7717/peerj.15669] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Accepted: 06/09/2023] [Indexed: 07/20/2023] Open
Abstract
Zirconia, a crystalline oxide of zirconium, holds good mechanical, optical, and biological properties. The metal-free restorations, mostly consisting of all-ceramic/zirconia restorations, are becoming popular restorative materials in restorative and prosthetic dentistry choices for aesthetic and biological reasons. Dental zirconia has increased over the past years producing wide varieties of zirconia for prosthetic restorations in dentistry. At present, literature is lacking on the recent zirconia biomaterials in dentistry. Currently, no article has the latest information on the various zirconia biomaterials in dentistry. Hence, the aim of this article is to present an overview of recent dental zirconia biomaterials and tends to classify the recent zirconia biomaterials in dentistry. This article is useful for dentists, dental technicians, prosthodontists, academicians, and researchers in the field of dental zirconia.
Collapse
Affiliation(s)
- Suchada Kongkiatkamon
- Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| | - Dinesh Rokaya
- Faculty of Dentistry, Zarqa University, Zarqa, Jordan
| | - Santiphab Kengtanyakich
- Prosthodontic Section, Department of Restorative Dentistry, Naresuan University, Phitsanulok, Thailand
| | - Chaimongkon Peampring
- Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| |
Collapse
|
31
|
Sun J, Pu T, Ding Q, Xu H, Kang Y, Zhang L. Digital replication and transfer of interim to definitive complete arch implant-supported fixed prostheses by using a laboratory scanner. J Prosthet Dent 2023:S0022-3913(23)00361-X. [PMID: 37453885 DOI: 10.1016/j.prosdent.2023.05.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 05/02/2023] [Accepted: 05/03/2023] [Indexed: 07/18/2023]
Abstract
The present technique describes an effective digital approach for the replication and transfer of occlusion, maxillomandibular relationship, and esthetic parameters from interim to definitive complete arch implant-supported fixed prostheses by laboratory scanning with transfer plates. Monolithic zirconia complete arch implant prostheses have been fabricated with satisfactory functional and esthetic outcomes.
Collapse
Affiliation(s)
- Jiao Sun
- Graduate student, Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, PR China
| | - Tingting Pu
- Dental Technician, Denture Processing Center, Peking University School and Hospital of Stomatology, Beijing, PR China
| | - Qian Ding
- Resident, Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, PR China.
| | - Hong Xu
- Dental Technician, Denture Processing Center, Peking University School and Hospital of Stomatology, Beijing, PR China
| | - Yanfeng Kang
- MDS Graduate, Department of Prosthodontics and Center for Oral Functional Diagnosis, Treatment and Research, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, PR China
| | - Lei Zhang
- Professor, Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, PR China
| |
Collapse
|
32
|
Wang J, Yang J, Lv K, Zhang H, Huang H, Jiang X. Can we use the translucency parameter to predict the CAD/CAM ceramic restoration aesthetic? Dent Mater 2023; 39:e1-e10. [PMID: 36841746 DOI: 10.1016/j.dental.2023.01.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 01/03/2023] [Accepted: 01/10/2023] [Indexed: 02/26/2023]
Abstract
OBJECTIVES To evaluate the effects of background color, ceramic type and coping thickness on masking ability (ΔE) and translucency parameter (TP) of CAD/CAM lithium disilicate glass-ceramic/monolithic zirconia and, to determine the correlations between coping thickness, TP and ΔE. METHODS A total of 120 ceramic specimens (2 mm, 1 mm and 0.5 mm thickness; n = 10) of four CAD/CAM ceramics: IPS e.max, IPS ZirCAD, Upcera Li CAD and Upcera TT CAD, were studied. Specimens were tested over nine fabricated backgrounds: A1, A2, A3.5, ND2 and ND7 shade resin-based composites, cobalt-chromium alloy (CC), medium precious alloy (MPA), black (B) and white (W). CIELab values (L*, a* and b*), color difference (ΔE) and translucency parameter (TP) were measured and calculated using a digital spectrophotometer (color i7, X-Rite, Pantone®). Data were analyzed using the Shapiro-Wilk test, one-way ANOVA, three-way ANOVA, independent t-tests and Tukey post-hoc tests (p < 0.05). RESULTS 2 mm CAD/CAM ceramics showed ideal color matching (ΔE<2.6) over different backgrounds, except for CC, B and W backgrounds. Monolithic zirconia had lower ΔE values than lithium disilicate glass-ceramics. ΔE and TP values significantly reduced with the increased coping thickness (p < 0.05). Regardless of ceramic type and thickness, a strong TP-SD of ΔE correlation was observed. SIGNIFICANCE CAD/CAM ceramic restoration color was significantly affected by background color, ceramic type and coping thickness. TP is a promising predictor for appropriate ceramic selection to receive an acceptable CAD/CAM ceramic restoration aesthetic.
Collapse
Affiliation(s)
- Jie Wang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China; College of Stomatology, Shanghai Jiao Tong University, Shanghai, China; National Center for Stomatology, Shanghai, China; National Clinical Research Center for Oral Diseases, Shanghai, China; Shanghai Key Laboratory of Stomatology, Shanghai, China; Shanghai Research Institute of Stomatology, Shanghai, China
| | - Jiawei Yang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China; College of Stomatology, Shanghai Jiao Tong University, Shanghai, China; National Center for Stomatology, Shanghai, China; National Clinical Research Center for Oral Diseases, Shanghai, China; Shanghai Key Laboratory of Stomatology, Shanghai, China; Shanghai Research Institute of Stomatology, Shanghai, China
| | - Kaige Lv
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China; College of Stomatology, Shanghai Jiao Tong University, Shanghai, China; National Center for Stomatology, Shanghai, China; National Clinical Research Center for Oral Diseases, Shanghai, China; Shanghai Key Laboratory of Stomatology, Shanghai, China; Shanghai Research Institute of Stomatology, Shanghai, China
| | - Hongming Zhang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China; College of Stomatology, Shanghai Jiao Tong University, Shanghai, China; National Center for Stomatology, Shanghai, China; National Clinical Research Center for Oral Diseases, Shanghai, China; Shanghai Key Laboratory of Stomatology, Shanghai, China; Shanghai Research Institute of Stomatology, Shanghai, China
| | - Hui Huang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China; College of Stomatology, Shanghai Jiao Tong University, Shanghai, China; National Center for Stomatology, Shanghai, China; National Clinical Research Center for Oral Diseases, Shanghai, China; Shanghai Key Laboratory of Stomatology, Shanghai, China; Shanghai Research Institute of Stomatology, Shanghai, China.
| | - Xinquan Jiang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China; College of Stomatology, Shanghai Jiao Tong University, Shanghai, China; National Center for Stomatology, Shanghai, China; National Clinical Research Center for Oral Diseases, Shanghai, China; Shanghai Key Laboratory of Stomatology, Shanghai, China; Shanghai Research Institute of Stomatology, Shanghai, China.
| |
Collapse
|
33
|
Potential Impact of Prosthetic Biomaterials on the Periodontium: A Comprehensive Review. Molecules 2023; 28:molecules28031075. [PMID: 36770741 PMCID: PMC9921997 DOI: 10.3390/molecules28031075] [Citation(s) in RCA: 22] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 01/14/2023] [Accepted: 01/17/2023] [Indexed: 01/24/2023] Open
Abstract
The success of a prosthetic treatment is closely related to the periodontal health of the individual. The aim of this article was to review and present the importance of prosthetic restorative materials on the condition of the periodontium, the changes that occur in the composition of the subgingival microbiota and the levels of inflammatory markers in gingival crevicular fluid. Articles on the influence of different prosthetic restorative materials on subgingival microbiota and proinflammatory cytokines were searched for using the keywords "prosthetic biomaterials", "fixed prosthesis", "periodontal health", "subgingival microbiota", "periodontal biomarkers" and "gingival crevicular fluid" in PubMed/Medline, Science Direct, Scopus and Google Scholar. The type of material used for prosthesis fabrication together with poor marginal and internal fit can result in changes in the composition of the subgingival microbiota, as well as increased accumulation and retention of dentobacterial plaque, thus favoring the development of periodontal disease and prosthetic treatment failure. Biological markers have helped to understand the inflammatory response of different prosthetic materials on periodontal tissues with the main purpose of improving their clinical application in patients who need them. Metal-free ceramic prostheses induce a lower inflammatory response regardless of the fabrication method; however, the use of CAD/CAM systems is recommended for their fabrication. In addition, it is presumed that metal-ceramic prostheses cause changes in the composition of the subgingival microbiota producing a more dysbiotic biofilm with a higher prevalence of periodontopathogenic bacteria, which may further favor periodontal deterioration.
Collapse
|
34
|
Nonaka K, Teramae M, Pezzotti G. Effect of Ga 2O 3 Dopant on High Speed Sintered 5 mol% Y 2O 3 Stabilized Dental Zirconia. MATERIALS (BASEL, SWITZERLAND) 2023; 16:714. [PMID: 36676451 PMCID: PMC9866617 DOI: 10.3390/ma16020714] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 01/05/2023] [Accepted: 01/05/2023] [Indexed: 06/17/2023]
Abstract
The high-speed sintering of zirconia has become essential for ceramic dental prosthesis treatment in a single visit. Previous studies have shown that 5 mol% yttria-stabilized zirconia (5Y zirconia), with the exception of some types, loses strength and translucency with high-speed sintering. In this study, 0.15-0.92 wt% Ga2O3, which is expected to promote the sintering of zirconia, was added to improve the properties of 5Y zirconia high-speed sintered bodies, and the effect of its addition was evaluated. The specimens were characterized by density and translucency measurements, a three-point bending test, X-ray diffraction (XRD), scanning electron microscopy (SEM), and shrinkage measurement. The addition of Ga2O3 improved both translucency and flexural strength of 5Y zirconia high-speed sintered bodies. XRD and SEM observations revealed that this improvement in properties was due to the change in the crystal phase composition and the decrease in the amount and size of pores due to the addition of Ga2O3. Shrinkage measurements also revealed that the addition of Ga2O3 changed the sintering behavior of 5Y zirconia, suggesting that this change led to a reduction in porosity. From the above results, it was concluded that Ga2O3 addition is effective in improving the properties of 5Y zirconia high-speed sintered bodies.
Collapse
Affiliation(s)
- Kazumichi Nonaka
- Department of Research and Development, SHOFU INC., Higashiyama-ku, Kyoto 605-0983, Japan
| | - Mitsuji Teramae
- Department of Research and Development, SHOFU INC., Higashiyama-ku, Kyoto 605-0983, Japan
| | - Giuseppe Pezzotti
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585, Japan
| |
Collapse
|
35
|
Saravi B, Flohr A, Patzelt SB, Spies BC, Hazard D, Kohal RJ. Fatigue and Fracture Resistance Testing of Polyether Ether Ketone (PEEK) Implant Abutments in an Ex Vivo Chewing Simulator Model. MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15196927. [PMID: 36234281 PMCID: PMC9573129 DOI: 10.3390/ma15196927] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 09/26/2022] [Accepted: 10/01/2022] [Indexed: 05/26/2023]
Abstract
Polyether ether ketone (PEEK) has been introduced into implant dentistry as a viable alternative to current implant abutment materials. However, data on its physico-mechanical properties are still scarce. The present study sought to shed light on this topic utilizing an ex vivo chewing simulator model. A total of 48 titanium two-piece implants were allocated into three groups (n = 16 per group): (1) implants with PEEK abutments and an internal butt-joint connection (PBJ), (2) implants with PEEK abutments and an internal conical implant-abutment connection (PC), and (3) implants with zirconia abutments and an internal butt-joint connection (ZA). All abutments were restored with a non-precious metal alloy crown mimicking the upper right central incisor. A dynamic chewing simulation of half (n = 8) of the specimens per group was performed with 5 × 106 cycles and a load of 49 N at a frequency of 1.7 Hz with thermocycling between 5 and 55 °C. The other eight specimens served as unloaded controls. Surface roughness, implant-abutment connection microgaps (IACMs), and the titanium base-abutment interface microgaps (TAIMs) in the loaded groups were evaluated. Finally, a quasi-static loading test was performed in a universal testing machine with all samples to evaluate fracture resistance. Overall, 23 samples survived the artificial chewing process. One abutment screw fracture was observed in the PC group. The ZA group showed higher surface roughness values than PEEK abutments. Furthermore, ZA revealed lower TAIM values compared to PEEK abutments. Similarly, ZA was associated with lower IACM values compared to PBJ. Fracture loads/bending moments were 1018 N/704 N cm for PBJ, 966 N/676 N cm for PC, and 738 N/508 N cm for ZA, with no significant differences compared to the unloaded references. Artificial loading did not significantly affect fracture resistance of the examined materials. PEEK abutments were associated with better load-bearing properties than zirconia abutments, although they showed higher microgap values. PEEK abutments could, therefore, be feasible alternatives to zirconia abutments based on the present ex vivo findings resembling 20 years of clinical service.
Collapse
Affiliation(s)
- Babak Saravi
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine, University of Freiburg, Medical Center—University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany
| | - Anselm Flohr
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center—University of Freiburg, Center for Dental Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany
| | - Sebastian B. Patzelt
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center—University of Freiburg, Center for Dental Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany
- Private Dental Clinic, Am Dorfplatz 3, 78658 Zimmern ob Rottweil, Germany
| | - Benedikt C. Spies
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center—University of Freiburg, Center for Dental Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany
| | - Derek Hazard
- Institute of Medical Biometry and Medical Statistics, Faculty of Medicine, Medical Center—University of Freiburg, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany
| | - Ralf J. Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center—University of Freiburg, Center for Dental Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany
| |
Collapse
|
36
|
Rutkunas V, Borusevicius R, Balciunas E, Jasinskyte U, Alksne M, Simoliunas E, Zlatev S, Ivanova V, Bukelskiene V, Mijiritsky E. The Effect of UV Treatment on Surface Contact Angle, Fibroblast Cytotoxicity, and Proliferation with Two Types of Zirconia-Based Ceramics. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:11113. [PMID: 36078826 PMCID: PMC9518570 DOI: 10.3390/ijerph191711113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 08/31/2022] [Accepted: 09/02/2022] [Indexed: 06/15/2023]
Abstract
UV photofunctionalization of Zirconia-based materials for abutment fabrication is a promising approach that might influence the formation of a sound peri-implant seal, thus promoting long-term soft and hard tissue implant integration. This study aimed to evaluate the effect of UV treatment of test specimens made by two different ZnO2-based ceramic materials on the hydrophilicity, cell cytotoxicity, and proliferation of human gingival fibroblasts (HGFs). Two Zirconia-based materials, high-translucent and ultra-translucent multi-layered Zirconia (Katana, Kuraray Noritake, Japan), were used to prepare a total of 40 specimens distributed in two equally sized groups based on the material (n = 20). The same surface finishing protocol was applied for all specimens, as suggested by the manufacturer. Half the specimens from each group were treated with UV-C light for 48 h. Water contact angle (WCA), fibroblast cytotoxicity, and proliferation were investigated. The WCA values for the high-translucent Zirconia ranged from 69.9° ± 6.4° to 73.7° ± 13.9° for the treated/non-treated specimens and from 79.5° ± 12.8° to 83.4° ± 11.4° for the ultra-translucent multi-layered Zirconia, respectively. However, the difference was insignificant (F(16) = 3.50, p = 0.292). No significant difference was observed for the fibroblast cytotoxicity test. The results for proliferation revealed a significant difference, which was material-dependent (F(8) = 9.58, p = 0.005). We found that UV surface photofunctionalization of ZrO2-based materials alters the human gingival fibroblast cell viability, which might produce favourable results for cell proliferation.
Collapse
Affiliation(s)
- Vygandas Rutkunas
- Institute of Odontology, Faculty of Medicine, Vilnius University, 03101 Vilnius, Lithuania
| | - Rokas Borusevicius
- Institute of Odontology, Faculty of Medicine, Vilnius University, 03101 Vilnius, Lithuania
| | - Evaldas Balciunas
- Institute of Biochemistry, Life Sciences Center, Vilnius University, 03101 Vilnius, Lithuania
| | - Urte Jasinskyte
- Institute of Biochemistry, Life Sciences Center, Vilnius University, 03101 Vilnius, Lithuania
| | - Milda Alksne
- Institute of Biochemistry, Life Sciences Center, Vilnius University, 03101 Vilnius, Lithuania
| | - Egidijus Simoliunas
- Institute of Biochemistry, Life Sciences Center, Vilnius University, 03101 Vilnius, Lithuania
| | - Stefan Zlatev
- CAD/CAM Center of Dental Medicine at the Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Vasilena Ivanova
- Oral Surgery Department, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Virginija Bukelskiene
- Institute of Biochemistry, Life Sciences Center, Vilnius University, 03101 Vilnius, Lithuania
| | - Eitan Mijiritsky
- Head and Neck Maxillofacial Surgery, Tel-Aviv Sourasky Medical Center, Department of Otolaryngology, Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv 699350, Israel
| |
Collapse
|
37
|
Amer A, Mohsen C, Hashem R. Effect of Nanosilica Incorporation on Flexural Strength, Shear Bond Strength, and Color of Veneering Porcelain after Thermocycling. Open Access Maced J Med Sci 2022. [DOI: 10.3889/oamjms.2022.10390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
AIM: The focus of this research was to see how silica nanoparticles changed veneering porcelain over a zirconia core affected flexure strength, shear bond strength, and color.
METHODS: A total number of 30 zirconia core veneer samples were constructed and classified according to silica nanoparticles modification of veneering porcelain into two groups: Group 1 (control group) veneering porcelain without any modification (n = 15) and Group 2 (modified group) veneering porcelain modified by silica nanoparticles (n = 15). Silica nanoparticles were added to the veneering porcelain powder at a rate of 5% by weight. Silica nanoparticles powder and veneering porcelain powder were manually crushed for about 10 min using a pestle and mortar then the mixed powder was combined with the porcelain moldings liquid to make a paste. After thermal cycling, each group was examined for flexural strength, shear bond strength, and color measurement (n = 5). Universal testing equipment was used to determine flexural and shear bond strength. The color shift was measured using a spectrophotometer.
RESULTS: Flexural strength levels in the modified group (280.9 ± 29.85 Mpa) were substantially higher than in the control group (431.78 ± 22.73 Mpa). Shear bond strength values in the modified group (34.31 ± 5.6) were significantly higher than in the control group (26.97 ± 4.03). Color change was within the clinical acceptable range (1.71 ± 0.32).
CONCLUSIONS: The addition of silica nanoparticles to veneering porcelain improved the flexural and shear bond strength, as well as, color change was within the clinical acceptable limits.
Collapse
|
38
|
Nonaka K, Teramae M, Pezzotti G. Evaluation of the Effect of High-Speed Sintering and Specimen Thickness on the Properties of 5 mol% Yttria-Stabilized Dental Zirconia Sintered Bodies. MATERIALS (BASEL, SWITZERLAND) 2022; 15:5685. [PMID: 36013827 PMCID: PMC9412651 DOI: 10.3390/ma15165685] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 08/08/2022] [Accepted: 08/13/2022] [Indexed: 06/15/2023]
Abstract
High-speed sintering of zirconia has become essential to single-visit dental prosthetic treatments. This important prosthetic dentistry technique demands a translucent material tougher than porcelain. Previous studies on high-speed sintered zirconia did not take heat and material thickness into consideration. We evaluated pre-sintered specimen thickness and the effect of high-speed sintering on the properties of 5 mol% Y2O3-stabilized zirconia (5Y zirconia). High-speed sintered bodies of 5Y zirconia were evaluated by density measurements, translucency measurements, three-point flexural and fracture toughness tests, X-ray diffraction (XRD), and scanning electron microscopy (SEM). High-speed sintering reduced the translucency and mechanical properties of 5Y zirconia. XRD and SEM observation results clarified that these reductions were due to the change in crystal phase composition and to the increase in residual pores, respectively, both resulting from high-speed sintering. Moreover, in high-speed sintering, as the thickness of the specimen increased, the number and size of internal pores increased, and the translucency and strength decreased. The threshold value for avoiding a reduction in translucency and mechanical properties was found to lie at ~4.4 mm. From the above results, it was concluded that 5Y zirconia is not suitable for high-speed sintering applications.
Collapse
Affiliation(s)
- Kazumichi Nonaka
- Department of Research and Development, SHOFU INC, Higashiyama-ku, Kyoto 605-0983, Japan
| | - Mitsuji Teramae
- Department of Research and Development, SHOFU INC, Higashiyama-ku, Kyoto 605-0983, Japan
| | - Giuseppe Pezzotti
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585, Japan
| |
Collapse
|
39
|
Insights and Advancements in Biomaterials for Prosthodontics and Implant Dentistry. Molecules 2022; 27:molecules27165116. [PMID: 36014357 PMCID: PMC9414069 DOI: 10.3390/molecules27165116] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 08/10/2022] [Indexed: 12/19/2022] Open
|