1
|
Xi H, Ross KE, Hinds J, Molino PJ, Whiley H. Efficacy of chlorine-based disinfectants to control Legionella within premise plumbing systems. WATER RESEARCH 2024; 259:121794. [PMID: 38824796 DOI: 10.1016/j.watres.2024.121794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 05/14/2024] [Accepted: 05/16/2024] [Indexed: 06/04/2024]
Abstract
Legionella is an opportunistic waterborne pathogen that causes Legionnaires' disease. It poses a significant public health risk, especially to vulnerable populations in health care facilities. It is ubiquitous in manufactured water systems and is transmitted via inhalation or aspiration of aerosols/water droplets generated from water fixtures (e.g., showers and hand basins). As such, the effective management of premise plumbing systems (building water systems) in health care facilities is essential for reducing the risk of Legionnaires' disease. Chemical disinfection is a commonly used control method and chlorine-based disinfectants, including chlorine, chloramine, and chlorine dioxide, have been used for over a century. However, the effectiveness of these disinfectants in premise plumbing systems is affected by various interconnected factors that can make it challenging to maintain effective disinfection. This systematic literature review identifies all studies that have examined the factors impacting the efficacy and decay of chlorine-based disinfectant within premise plumbing systems. A total of 117 field and laboratory-based studies were identified and included in this review. A total of 20 studies directly compared the effectiveness of the different chlorine-based disinfectants. The findings from these studies ranked the typical effectiveness as follows: chloramine > chlorine dioxide > chlorine. A total of 26 factors were identified across 117 studies as influencing the efficacy and decay of disinfectants in premise plumbing systems. These factors were sorted into categories of operational factors that are changed by the operation of water devices and fixtures (such as stagnation, temperature, water velocity), evolving factors which are changed in-directly (such as disinfectant concentration, Legionella disinfectant resistance, Legionella growth, season, biofilm and microbe, protozoa, nitrification, total organic carbon(TOC), pH, dissolved oxygen(DO), hardness, ammonia, and sediment and pipe deposit) and stable factors that are not often changed(such as disinfectant type, pipe material, pipe size, pipe age, water recirculating, softener, corrosion inhibitor, automatic sensor tap, building floor, and construction activity). A factor-effect map of each of these factors and whether they have a positive or negative association with disinfection efficacy against Legionella in premise plumbing systems is presented. It was also found that evaluating the effectiveness of chlorine disinfection as a water risk management strategy is further complicated by varying disinfection resistance of Legionella species and the form of Legionella (culturable/viable but non culturable, free living/biofilm associated, intracellular replication within amoeba hosts). Future research is needed that utilises sensors and other approaches to measure these key factors (such as pH, temperature, stagnation, water age and disinfection residual) in real time throughout premise plumbing systems. This information will support the development of improved models to predict disinfection within premise plumbing systems. The findings from this study will inform the use of chlorine-based disinfection within premise plumbing systems to reduce the risk of Legionnaires disease.
Collapse
Affiliation(s)
- Hao Xi
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia; Enware Pty Ltd, Caringbah, NSW, Australia.
| | - Kirstin E Ross
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
| | - Jason Hinds
- ARC Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia; Enware Pty Ltd, Caringbah, NSW, Australia
| | | | - Harriet Whiley
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia; ARC Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia
| |
Collapse
|
2
|
Zayed AR, Burghal M, Butmeh S, Samba-Louaka A, Steinert M, Bitar DM. Legionella pneumophila Presence in Dental Unit Waterlines: A Cultural and Molecular Investigation in the West Bank, Palestine. Trop Med Infect Dis 2023; 8:490. [PMID: 37999609 PMCID: PMC10675536 DOI: 10.3390/tropicalmed8110490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 10/15/2023] [Accepted: 10/25/2023] [Indexed: 11/25/2023] Open
Abstract
A Legionella pneumophila bacterium is ubiquitous in water distribution systems, including dental unit waterlines (DUWLs). Legionellosis is atypical pneumonia, including Legionnaires' disease (LD) and the less acute form of Pontiac fever. Legionellosis occurs as a result of inhalation/aspiration of aerosolized Legionella-contaminated water by susceptible patients, health workers, and dentists. In this study, we undertook to determine the prevalence of Legionella in water and biofilm samples from Tap and DUWLs collected from five sites of dental clinics and faculties across the West Bank. Water samples were tested for physical and chemical parameters. The study samples included 185 samples, 89 (48%) water samples, and 96 (52%) biofilm swabs, which were analyzed by cultivation-dependent analysis (CDA) and by the cultivation-independent technique (CIA). Also, partial sequencing of the 16S rRNA gene for fifteen L. pneumophila isolates was performed for quality assurance and identification. L. pneumophila was isolated from 28 (15%) of 185 samples using CDA and was detected in 142 (77%) of 185 samples using CIA. The abundance of culturable L. pneumophila was low in DUWL of the sampling sites (range: 27-115 CFU/Liter). PCR was 5× more sensitive than the culture technique. L. pneumophila Sg 1 was detected in (75%) of the isolates, while (25%) isolates were L. pneumophila Sg 2-14. All fifteen sequenced Legionella isolates were identified as L. pneumophila ≥ 94.5%. The analysis of phylogenetic tree showed that L. pneumophila branch clearly identified and distinguished from other branches. These results show that DUWLs of the examined dental clinics and faculties are contaminated with L. pneumophila. This finding reveals a serious potential health risk for infection of immunocompromised patients and dentists' post-exposure.
Collapse
Affiliation(s)
- Ashraf R. Zayed
- Department of Biomedical Sciences, Faculty of Medicine and Health Sciences, An-Najah National University, Nablus P.O. Box 7, Palestine
| | - Mutasem Burghal
- Microbiology Research Laboratory, Faculty of Medicine, Al-Quds University, Abu-Dies, East Jerusalem P.O. Box 51000, Palestine; (M.B.); (S.B.)
| | - Suha Butmeh
- Microbiology Research Laboratory, Faculty of Medicine, Al-Quds University, Abu-Dies, East Jerusalem P.O. Box 51000, Palestine; (M.B.); (S.B.)
| | - Ascel Samba-Louaka
- Laboratoire Ecologie et Biologie des Interactions, Université de Poitiers, UMR CNRS 7267, 86000 Poitiers, France;
| | - Michael Steinert
- Institut für Mikrobiologie, Technische Universität Braunschweig, 38106 Braunschweig, Germany;
| | - Dina M. Bitar
- Microbiology Research Laboratory, Faculty of Medicine, Al-Quds University, Abu-Dies, East Jerusalem P.O. Box 51000, Palestine; (M.B.); (S.B.)
| |
Collapse
|
3
|
Song Y, Finkelstein R, Rhoads W, Edwards MA, Pruden A. Shotgun Metagenomics Reveals Impacts of Copper and Water Heater Anodes on Pathogens and Microbiomes in Hot Water Plumbing Systems. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:13612-13624. [PMID: 37643149 PMCID: PMC10501123 DOI: 10.1021/acs.est.3c03568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 07/24/2023] [Accepted: 07/25/2023] [Indexed: 08/31/2023]
Abstract
Hot water building plumbing systems are vulnerable to the proliferation of opportunistic pathogens (OPs), including Legionella pneumophila and Mycobacterium avium. Implementation of copper as a disinfectant could help reduce OPs, but a mechanistic understanding of the effects on the microbial community under real-world plumbing conditions is lacking. Here, we carried out a controlled pilot-scale study of hot water systems and applied shotgun metagenomic sequencing to examine the effects of copper dose (0-2 mg/L), orthophosphate corrosion control agent, and water heater anode materials (aluminum vs magnesium vs powered anode) on the bulk water and biofilm microbiome composition. Metagenomic analysis revealed that, even though a copper dose of 1.2 mg/L was required to reduce Legionella and Mycobacterium numbers, lower doses (e.g., ≤0.6 mg/L) measurably impacted the broader microbial community, indicating that the OP strains colonizing these systems were highly copper tolerant. Orthophosphate addition reduced bioavailability of copper, both to OPs and to the broader microbiome. Functional gene analysis indicated that both membrane damage and interruption of nucleic acid replication are likely at play in copper inactivation mechanisms. This study identifies key factors (e.g., orthophosphate, copper resistance, and anode materials) that can confound the efficacy of copper for controlling OPs in hot water plumbing.
Collapse
Affiliation(s)
- Yang Song
- Civil
and Environmental Engineering, Virginia
Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, Virginia 24061, United States
- Utilities
Department, Town of Cary, 316 N. Academy St., Cary, North Carolina 27512, United States
| | - Rachel Finkelstein
- Civil
and Environmental Engineering, Virginia
Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, Virginia 24061, United States
- AECOM, 3101 Wilson Boulevard, Arlington, Virginia 22201, United States
| | - William Rhoads
- Civil
and Environmental Engineering, Virginia
Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, Virginia 24061, United States
- Black
& Veatch, 8400 Ward
Pkwy, Kansas City, Missouri 64114, United States
| | - Marc A. Edwards
- Civil
and Environmental Engineering, Virginia
Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, Virginia 24061, United States
| | - Amy Pruden
- Civil
and Environmental Engineering, Virginia
Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, Virginia 24061, United States
| |
Collapse
|
4
|
Gea-Izquierdo E, Gil-de-Miguel Á, Rodríguez-Caravaca G. Legionella pneumophila Risk from Air–Water Cooling Units Regarding Pipe Material and Type of Water. Microorganisms 2023; 11:microorganisms11030638. [PMID: 36985212 PMCID: PMC10053303 DOI: 10.3390/microorganisms11030638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Revised: 02/27/2023] [Accepted: 02/28/2023] [Indexed: 03/06/2023] Open
Abstract
Legionellosis is a respiratory disease related to environmental health. There have been manifold studies of pipe materials, risk installations and legionellosis without considering the type of transferred water. The objective of this study was to determine the potential development of the causative agent Legionella pneumophila regarding air–water cooling units, legislative compliance, pipe material and type of water. Forty-four hotel units in Andalusia (Spain) were analysed with respect to compliance with Spanish health legislation for the prevention of legionellosis. The chi-square test was used to explain the relationship between material–water and legislative compliance, and a biplot of the first two factors was generated. Multiple correspondence analysis (MCA) was performed on the type of equipment, legislative compliance, pipe material and type of water, and graphs of cases were constructed by adding confidence ellipses by categories of the variables. Pipe material–type of water (p value = 0.29; p < 0.05) and legislative compliance were not associated (p value = 0.15; p < 0.05). Iron, stainless steel, and recycled and well water contributed the most to the biplot. MCA showed a global pattern in which lead, iron and polyethylene were well represented. Confidence ellipses around categories indicated significant differences among categories. Compliance with Spanish health legislation regarding the prevention and control of legionellosis linked to pipe material and type of water was not observed.
Collapse
Affiliation(s)
- Enrique Gea-Izquierdo
- Preventive Medicine and Public Health, Rey Juan Carlos University, 28922 Madrid, Spain
- Maria Zambrano Program, European Union, Spain
- Correspondence:
| | - Ángel Gil-de-Miguel
- Preventive Medicine and Public Health, Rey Juan Carlos University, 28922 Madrid, Spain
- CIBER of Respiratory Diseases (CIBERES), Instituto de Salud Carlos III, 28029 Madrid, Spain
| | - Gil Rodríguez-Caravaca
- Preventive Medicine and Public Health, Rey Juan Carlos University, 28922 Madrid, Spain
- Department of Preventive Medicine, Hospital Universitario Fundación Alcorcón, Universidad Rey Juan Carlos, 28922 Madrid, Spain
| |
Collapse
|
5
|
Molina JJ, Bennassar M, Palacio E, Crespi S. Impact of prolonged hotel closures during the COVID-19 pandemic on Legionella infection risks. Front Microbiol 2023; 14:1136668. [PMID: 36910223 PMCID: PMC9998907 DOI: 10.3389/fmicb.2023.1136668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 02/10/2023] [Indexed: 03/14/2023] Open
Abstract
In general, it is accepted that water stagnation and lack or poor maintenance in buildings are risk factors for Legionella growth. Then, in theory, the prolonged hotel closures due to the COVID-19 pandemic may have increased the risk of Legionella infections. However, there are very few field studies comparing the level of Legionella colonization in buildings before the pandemic and the new situation created after the lockdown. The objective of this study was to analyze these differences in a group of hotels that experienced prolonged closures in 2020 due to the COVID-19 pandemic. We have studied the Legionella spp. results, analyzed by standard culture, from the domestic water distribution systems of 73 hotels that experienced closures (from 1 to >4 months) during 2020, immediately after the reopening. The results were compared with those obtained in similar samplings of 2019. For the comparative analysis, we divided the hotels in two groups: Group A that have suffered closures for ≤3 months and Group B that remained closed for more than 3 months, both in relation to the opening period of 2019. In the Group B (36 sites), the frequency of positive samples in the hot water system increased from 6.7% in 2019 to 14.0% in 2020 (p < 0.05). In the Group A (37 sites), no significant differences were observed. No statistically significant differences were observed in terms of positive sites (defined as hotels with at least 1 positive sample), Legionella spp. concentrations and prevalence of Legionella pneumophila sg1 between the samplings of the two periods studied. The results suggest that hotels that suffered the longest prolonged closures (> 3 months) could have carried a higher risk of exposure to Legionella in the domestic hot water system. These findings highlight the importance of adequate preopening cleaning and disinfection procedures for hotel water systems, and the convenience of considering the most effective disinfection methods especially for hot water systems and after prolonged closure periods.
Collapse
Affiliation(s)
- Jhon J. Molina
- Environmental Health and Laboratory Services, Biolinea Int., Palma, Spain
- Environmental Analytical Chemistry Laboratory, Department of Chemistry, University of the Balearic Islands, Palma, Spain
| | | | - Edwin Palacio
- Environmental Analytical Chemistry Laboratory, Department of Chemistry, University of the Balearic Islands, Palma, Spain
| | - Sebastian Crespi
- Environmental Health and Laboratory Services, Biolinea Int., Palma, Spain
| |
Collapse
|
6
|
Ezell JM, Chase EC. Forming a Critical Race Theory of Environmental Disaster: Understanding social meanings and health threat perception in the Flint Water Crisis. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2022; 320:115886. [PMID: 36056493 DOI: 10.1016/j.jenvman.2022.115886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 07/20/2022] [Accepted: 07/25/2022] [Indexed: 06/15/2023]
Abstract
A Critical Race Theory of Environmental Disaster can aid researchers in better contextualizing racially disproportionate environmental disasters and their intricate social meanings to survivors. Such a theory, as proposed and operationalized here, incorporates interpretations of the causes and consequences of environmental disaster. In so doing, this theory weighs the racial and economic stratification often preceding environmental disaster and that which reflexively becomes more embedded in the aftermath. Focusing on the water crisis in the racially diverse, socioeconomically diminished city of Flint, Michigan, this article examines survey data from research conducted with city residents. The analysis considers residents' attitudes and beliefs around the crisis' scope and its intentionality and residents' health outcomes. Results suggest that various institutional and community-level mechanisms contribute to processes of meaning-making during crisis, or "crisis-making," finding consistent variation in residents' understanding of the nature and scope of the water crisis that is associated with specific cultural and health-related experiences. This construction substantiates that a Critical Race Theory of Environmental Disaster must consider not only race, but class in the context of race, as instrumental in developing social understandings of, and experiences with, environmental disaster.
Collapse
Affiliation(s)
- Jerel M Ezell
- General Internal Medicine, Weill Cornell Medicine, New York, NY, USA; Center for Cultural Humility, Cornell University, Ithaca, NY, USA.
| | - Elizabeth C Chase
- Department of Biostatistics, School of Public Health, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
7
|
McLaren SJ, Sahli MW, Selig S, Masten SJ, Page WH. The drinking water crises of Flint and Havelock North: a failure of public health risk management. JOURNAL OF WATER AND HEALTH 2022; 20:1314-1328. [PMID: 36170188 DOI: 10.2166/wh.2022.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Between 2014 and 2016, there were two severe community water system (CWS) failures in Flint, Michigan (MI), USA and Havelock North, Hawkes Bay, New Zealand. These events had profound implications for public health in their respective countries. While the nature of both crises was different, certain aspects of the failings were strikingly similar. These included: failure of authorities to protect the integrity of their source water, 'wait-and-see approach' to address problems if and when they occurred, negligent approach to regulatory oversight and responsibility, substandard facilities and lack of knowledge and training of staff, failure of consultants and advisory services engaged by suppliers, and failure of government agencies to enforce regulations. The lessons from both incidents must be learned, or similar tragic events are likely to reoccur. The six principles identified in the Government Inquiry into the Havelock North outbreak are an essential first step. The next step is to implement them throughout the drinking water sector.
Collapse
Affiliation(s)
- S J McLaren
- College of Health, Massey University, Wellington, New Zealand
| | - M W Sahli
- Department of Public Health and Health Sciences, Coolege of Health Sciences, University of Michigan-Flint, Flint, MI, USA
| | - S Selig
- Department of Public Health and Health Sciences, Coolege of Health Sciences, University of Michigan-Flint, Flint, MI, USA
| | - S J Masten
- Department of Civil and Environmental Engineering, Michigan State University, East Lansing, MI, USA E-mail:
| | - W H Page
- College of Health, Massey University, Wellington, New Zealand
| |
Collapse
|
8
|
Jereb G, Eržen I, Oder M, Poljšak B. Phosphate drinking water softeners promote Legionella growth. JOURNAL OF WATER AND HEALTH 2022; 20:1084-1090. [PMID: 35902990 DOI: 10.2166/wh.2022.055] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Phosphate-based drinking water softeners are commonly used to prevent scale formation in drinking water distribution infrastructure. The main reason for drinking water softening is primarily economic (protection of pipes and extension of equipment life), while the health aspect of such treatment is usually neglected. The aim of this work is to investigate the effects of phosphate-based drinking water softeners on growth stimulation of Legionella pneumophila. Bacterial growth was observed at two different phosphate concentrations. On average, an increase in growth of 1.19-1.28 log CFU/mL was observed in selected samples with added phosphates compared with the control. The results of the in vitro experiment confirmed that the added phosphates stimulate the growth of L. pneumophila; growth stimulation could therefore be expected in drinking water distribution systems (DWDS) when phosphates are used as well. The availability of phosphorus in DWDS may be a crucial limiting factor for biofouling control. Consequently, phosphate-based chemicals for drinking water should be avoided or used with prudence, especially in drinking water with high concentrations of other nutrients.
Collapse
Affiliation(s)
- Gregor Jereb
- Faculty of Health Sciences, University of Ljubljana, Zdravstvena pot 5, 1000 Ljubljana, Slovenia E-mail: ; Faculty of Medicine, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia
| | - Ivan Eržen
- Faculty of Medicine, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia; The National Institute of Public Health, Trubarjeva 2, 1000 Ljubljana, Slovenia
| | - Martina Oder
- Faculty of Health Sciences, University of Ljubljana, Zdravstvena pot 5, 1000 Ljubljana, Slovenia E-mail:
| | - Borut Poljšak
- Faculty of Health Sciences, University of Ljubljana, Zdravstvena pot 5, 1000 Ljubljana, Slovenia E-mail:
| |
Collapse
|
9
|
Talapko J, Frauenheim E, Juzbašić M, Tomas M, Matić S, Jukić M, Samardžić M, Škrlec I. Legionella pneumophila-Virulence Factors and the Possibility of Infection in Dental Practice. Microorganisms 2022; 10:microorganisms10020255. [PMID: 35208710 PMCID: PMC8879694 DOI: 10.3390/microorganisms10020255] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 01/08/2022] [Accepted: 01/21/2022] [Indexed: 02/07/2023] Open
Abstract
Legionella pneumophila is defined as a bacterium that can cause severe pneumonia. It is found in the natural environment and in water, and is often found in water tanks. It can be an integral part of biofilms in nature, and the protozoa in which it can live provide it with food and protect it from harmful influences; therefore, it has the ability to move into a sustainable but uncultured state (VBNC). L. pneumophila has been shown to cause infections in dental practices. The most common transmission route is aerosol generated in dental office water systems, which can negatively affect patients and healthcare professionals. The most common way of becoming infected with L. pneumophila in a dental office is through water from dental instruments, and the dental unit. In addition to these bacteria, patients and the dental team may be exposed to other harmful bacteria and viruses. Therefore, it is vital that the dental team regularly maintains and decontaminates the dental unit, and sterilizes all accessories that come with it. In addition, regular water control in dental offices is necessary.
Collapse
Affiliation(s)
- Jasminka Talapko
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
| | - Erwin Frauenheim
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
| | - Martina Juzbašić
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
| | - Matej Tomas
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
| | - Suzana Matić
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
- Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, Josipa Huttlera 4, HR-31000 Osijek, Croatia
| | - Melita Jukić
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
- General Hospital Vukovar, Županijska 35, HR-32000 Vukovar, Croatia
| | - Marija Samardžić
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
| | - Ivana Škrlec
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
- Correspondence:
| |
Collapse
|
10
|
Optimal Placement and Operation of Chlorine Booster Stations: A Multi-Level Optimization Approach. ENERGIES 2021. [DOI: 10.3390/en14185806] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Chlorine demand as a disinfectant for water utility impacts on unintended energy consumption from electrolysis manufacture; thus, diminishing the chlorine consumption also reduces the environmental impact and energy consumption. Problems of disinfectant distribution and uniformity in Water Distribution Networks (WDN) are associated with the exponential urban growth and the physical and biochemical difficulties within the network. This study optimizes Chlorine Booster Stations (CBS) location on a network with two main objectives; (1) to deliver minimal Free Residual Chlorine (FRC) throughout all demand nodes according to country regulations, and (2) to reduce day chlorine mass concentration supplied in the system by applying an hour time pattern in CBS, consequently associated economic, energy and environmental impacts complying with regulatory standards. The application is demonstrated on a real-world WDN modeled from Guanajuato, Mexico. The resulting optimal location and disinfectant dosage schedule in CBS provided insights on maintaining disinfectant residuals throughout all the WDN to prevent health issues and diminishing chlorine consumption.
Collapse
|
11
|
Roy S, Mosteller K, Mosteller M, Webber K, Webber V, Webber S, Reid L, Walters L, Edwards MA. Citizen science chlorine surveillance during the Flint, Michigan federal water emergency. WATER RESEARCH 2021; 201:117304. [PMID: 34107367 DOI: 10.1016/j.watres.2021.117304] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/25/2020] [Revised: 04/30/2021] [Accepted: 05/24/2021] [Indexed: 05/12/2023]
Abstract
Rising incidence of waterborne diseases including Legionellosis linked to low chlorine residuals in buildings and the availability of inexpensive testing options, create an opportunity for citizen science chorine monitoring to complement sampling done by water utilities. University researchers and Flint residents coordinated a citizen science chlorine surveillance campaign in Flint, Michigan in 2015-19, that helped expose the nature of two deadly Legionnaires Disease outbreaks in 2014-2015 during the Flint Water Crisis and progress of system recovery during the Federal emergency. Results obtained with an inexpensive color wheel were in agreement with a digital colorimeter (R2 =0.99; p = 2.81 × 10-21) at 15 sites geographically distributed across Flint. Blinded tests revealed good agreement between official (n = 2051) and citizen (n = 654) data in terms of determining whether regulatory guidelines for chlorine were met, but a discovery that the citizen data were statistically lower than the city's (p<0.00001) especially in warm summer months led to recommendations for increased flushing of service lines before measurements. This work suggests that expanded citizen surveillance of chlorine, site specific flushing advice, and guidance on decisions about water heater set point could help consumers reduce Legionella risks in their homes. Citizen science initiatives for chlorine monitoring offer a unique opportunity for mutually beneficial collaborations between consumers and utilities to reduce the main source of waterborne disease in developed countries.
Collapse
Affiliation(s)
- Siddhartha Roy
- Civil and Environmental Engineering, Virginia Tech, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Causes, Factors, and Control Measures of Opportunistic Premise Plumbing Pathogens—A Critical Review. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11104474] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
This review critically analyses the chemical and physical parameters that influence the occurrence of opportunistic pathogens in the drinking water distribution system, specifically in premise plumbing. A comprehensive literature review reveals significant impacts of water age, disinfectant residual (type and concentration), temperature, pH, and pipe materials. Evidence suggests that there is substantial interplay between these parameters; however, the dynamics of such relationships is yet to be elucidated. There is a correlation between premise plumbing system characteristics, including those featuring water and energy conservation measures, and increased water quality issues and public health concerns. Other interconnected issues exacerbated by high water age, such as disinfectant decay and reduced corrosion control efficiency, deserve closer attention. Some common features and trends in the occurrence of opportunistic pathogens have been identified through a thorough analysis of the available literature. It is proposed that the efforts to reduce or eliminate their incidence might best focus on these common features.
Collapse
|
13
|
Bédard E, Trigui H, Liang J, Doberva M, Paranjape K, Lalancette C, Allegra S, Faucher SP, Prévost M. Local Adaptation of Legionella pneumophila within a Hospital Hot Water System Increases Tolerance to Copper. Appl Environ Microbiol 2021; 87:e00242-21. [PMID: 33674435 PMCID: PMC8117758 DOI: 10.1128/aem.00242-21] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 02/25/2021] [Indexed: 11/20/2022] Open
Abstract
In large-building water systems, Legionella pneumophila is exposed to common environmental stressors such as copper. The aim of this study was to evaluate the susceptibility to copper of L. pneumophila isolates recovered from various sites: two clinical and seven environmental isolates from hot water system biofilm and water and from cooling tower water. After a 1-week acclimation in simulated drinking water, strains were exposed to various copper concentrations (0.8 to 5 mg/liter) for over 672 h. Complete loss of culturability was observed for three isolates following copper exposure to 5 mg/liter for 672 h. Two sequence type 1427 (ST1427)-like isolates were highly sensitive to copper, while the other two, isolated from biofilm samples, maintained higher culturability. The expression of the copper resistance gene copA evaluated by reverse transcription-quantitative PCR (RT-qPCR) was significantly higher for the biofilm isolates. All four ST1427-like isolates were recovered from the same water system during an outbreak. Whole-genome sequencing results confirmed that the four isolates are very close phylogenetically, differing by only 29 single nucleotide polymorphisms, suggesting in situ adaptation to microenvironmental conditions, possibly due to epigenetic regulation. These results indicate that the immediate environment within a building water distribution system influences the tolerance of L. pneumophila to copper. Increased contact of L. pneumophila biofilm strains with copper piping or copper alloys in the heat exchanger might lead to local adaptation. The phenotypic differences observed between water and biofilm isolates from the hot water system of a health care facility warrants further investigation to assess the relevance of evaluating disinfection performances based on water sampling alone.IMPORTANCELegionella pneumophila is a pathogen indigenous to natural and large building water systems in the bulk and the biofilm phases. The immediate environment within a system can impact the tolerance of L. pneumophila to environmental stressors, including copper. In health care facilities, copper levels in water can vary, depending on water quality, plumbing materials, and age. This study evaluated the impact of the isolation site (water versus biofilm, hot water system versus cooling tower) within building water systems. Closely related strains isolated from a health care facility hot water system exhibited variable tolerance to copper stress, shown by differential expression of copA, with biofilm isolates displaying highest expression and tolerance. Relying on the detection of L. pneumophila in water samples following exposure to environmental stressors such as copper may underestimate the prevalence of L. pneumophila, leading to inappropriate risk management strategies and increasing the risk of exposure for vulnerable patients.
Collapse
Affiliation(s)
- Emilie Bédard
- Department of Civil Engineering, Polytechnique Montréal, Montréal, Quebec, Canada
- Department of Natural Resource Sciences, Faculty of Agricultural and Environmental Sciences, McGill University, Sainte-Anne-de-Bellevue, Quebec, Canada
| | - Hana Trigui
- Department of Civil Engineering, Polytechnique Montréal, Montréal, Quebec, Canada
| | - Jeffrey Liang
- Department of Natural Resource Sciences, Faculty of Agricultural and Environmental Sciences, McGill University, Sainte-Anne-de-Bellevue, Quebec, Canada
| | - Margot Doberva
- Department of Civil Engineering, Polytechnique Montréal, Montréal, Quebec, Canada
| | - Kiran Paranjape
- Department of Natural Resource Sciences, Faculty of Agricultural and Environmental Sciences, McGill University, Sainte-Anne-de-Bellevue, Quebec, Canada
| | - Cindy Lalancette
- Laboratoire de Santé Publique du Québec, Sainte-Anne-de-Bellevue, Quebec, Canada
| | - Séverine Allegra
- University of Lyon, UJM-Saint-Etienne, UMR 5600 CNRS, EVS-ISTHME, Saint-Etienne, France
| | - Sebastien P Faucher
- Department of Natural Resource Sciences, Faculty of Agricultural and Environmental Sciences, McGill University, Sainte-Anne-de-Bellevue, Quebec, Canada
| | - Michèle Prévost
- Department of Civil Engineering, Polytechnique Montréal, Montréal, Quebec, Canada
| |
Collapse
|
14
|
Chambers ST, Slow S, Scott-Thomas A, Murdoch DR. Legionellosis Caused by Non- Legionella pneumophila Species, with a Focus on Legionella longbeachae. Microorganisms 2021; 9:291. [PMID: 33572638 PMCID: PMC7910863 DOI: 10.3390/microorganisms9020291] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/23/2021] [Accepted: 01/26/2021] [Indexed: 12/13/2022] Open
Abstract
Although known as causes of community-acquired pneumonia and Pontiac fever, the global burden of infection caused by Legionella species other than Legionella pneumophila is under-recognised. Non-L. pneumophila legionellae have a worldwide distribution, although common testing strategies for legionellosis favour detection of L. pneumophila over other Legionella species, leading to an inherent diagnostic bias and under-detection of cases. When systematically tested for in Australia and New Zealand, L. longbeachae was shown to be a leading cause of community-acquired pneumonia. Exposure to potting soils and compost is a particular risk for infection from L. longbeachae, and L. longbeachae may be better adapted to soil and composting plant material than other Legionella species. It is possible that the high rate of L. longbeachae reported in Australia and New Zealand is related to the composition of commercial potting soils which, unlike European products, contain pine bark and sawdust. Genetic studies have demonstrated that the Legionella genomes are highly plastic, with areas of the chromosome showing high levels of recombination as well as horizontal gene transfer both within and between species via plasmids. This, combined with various secretion systems and extensive effector repertoires that enable the bacterium to hijack host cell functions and resources, is instrumental in shaping its pathogenesis, survival and growth. Prevention of legionellosis is hampered by surveillance systems that are compromised by ascertainment bias, which limits commitment to an effective public health response. Current prevention strategies in Australia and New Zealand are directed at individual gardeners who use potting soils and compost. This consists of advice to avoid aerosols generated by the use of potting soils and use masks and gloves, but there is little evidence that this is effective. There is a need to better understand the epidemiology of L. longbeachae and other Legionella species in order to develop effective treatment and preventative strategies globally.
Collapse
Affiliation(s)
- Stephen T. Chambers
- Department of Pathology and Biomedical Science, University of Otago, Christchurch 8011, New Zealand; (S.S.); (A.S.-T.); (D.R.M.)
| | | | | | | |
Collapse
|
15
|
Editorial Comments to the Special Issue: " Legionella Contamination in Water Environment". Pathogens 2020; 9:pathogens9121017. [PMID: 33276607 PMCID: PMC7761553 DOI: 10.3390/pathogens9121017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 12/01/2020] [Indexed: 11/29/2022] Open
|
16
|
Cullom AC, Martin RL, Song Y, Williams K, Williams A, Pruden A, Edwards MA. Critical Review: Propensity of Premise Plumbing Pipe Materials to Enhance or Diminish Growth of Legionella and Other Opportunistic Pathogens. Pathogens 2020; 9:E957. [PMID: 33212943 PMCID: PMC7698398 DOI: 10.3390/pathogens9110957] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 11/12/2020] [Accepted: 11/13/2020] [Indexed: 12/20/2022] Open
Abstract
Growth of Legionella pneumophila and other opportunistic pathogens (OPs) in drinking water premise plumbing poses an increasing public health concern. Premise plumbing is constructed of a variety of materials, creating complex environments that vary chemically, microbiologically, spatially, and temporally in a manner likely to influence survival and growth of OPs. Here we systematically review the literature to critically examine the varied effects of common metallic (copper, iron) and plastic (PVC, cross-linked polyethylene (PEX)) pipe materials on factors influencing OP growth in drinking water, including nutrient availability, disinfectant levels, and the composition of the broader microbiome. Plastic pipes can leach organic carbon, but demonstrate a lower disinfectant demand and fewer water chemistry interactions. Iron pipes may provide OPs with nutrients directly or indirectly, exhibiting a high disinfectant demand and potential to form scales with high surface areas suitable for biofilm colonization. While copper pipes are known for their antimicrobial properties, evidence of their efficacy for OP control is inconsistent. Under some circumstances, copper's interactions with premise plumbing water chemistry and resident microbes can encourage growth of OPs. Plumbing design, configuration, and operation can be manipulated to control such interactions and health outcomes. Influences of pipe materials on OP physiology should also be considered, including the possibility of influencing virulence and antibiotic resistance. In conclusion, all known pipe materials have a potential to either stimulate or inhibit OP growth, depending on the circumstances. This review delineates some of these circumstances and informs future research and guidance towards effective deployment of pipe materials for control of OPs.
Collapse
Affiliation(s)
- Abraham C. Cullom
- Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, VA 24061, USA; (A.C.C.); (R.L.M.); (Y.S.); (A.P.)
| | - Rebekah L. Martin
- Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, VA 24061, USA; (A.C.C.); (R.L.M.); (Y.S.); (A.P.)
- Civil and Environmental Engineering, Virginia Military Institute, Lexington, VA 24450, USA
| | - Yang Song
- Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, VA 24061, USA; (A.C.C.); (R.L.M.); (Y.S.); (A.P.)
| | | | - Amanda Williams
- c/o Marc Edwards, Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, VA 24061, USA;
| | - Amy Pruden
- Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, VA 24061, USA; (A.C.C.); (R.L.M.); (Y.S.); (A.P.)
| | - Marc A. Edwards
- Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, VA 24061, USA; (A.C.C.); (R.L.M.); (Y.S.); (A.P.)
| |
Collapse
|