1
|
殷 漫, 邓 曌, 苗 娅, 张 晓. [Investigation of the Biosafety of Commercially Available Natural Rubber Latex and Synthetic Polyurethane Condom Materials]. SICHUAN DA XUE XUE BAO. YI XUE BAN = JOURNAL OF SICHUAN UNIVERSITY. MEDICAL SCIENCE EDITION 2024; 55:958-963. [PMID: 39170021 PMCID: PMC11334296 DOI: 10.12182/20240760209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/23/2024] [Indexed: 08/23/2024]
Abstract
Objective To investigate the biological safety of commercially available natural rubber latex and synthetic polyurethane condoms. Methods Natural rubber latex condom brands of A1 and A2 and polyurethane condom brands of B1 and B2 were purchased from large chain pharmacies in Chengdu, with three packages randomly selected for each brand. The study assessed the toxic effects of condom extracts on L-929 mouse fibroblasts according to GB/T standards. Gross observation and histopathological evaluation were conducted to assess the irritation reactions of condoms on the vagina and penis of rabbits (3 rabbits were used for each brand), as well as their sensitization effects on guinea pig skin. Additionally, the impact of continuous perfusion of condom extracts of the vaginas of SD rats for 30 days on their reproductive systems was evaluated, following GB/T standards (5 rats were used for each brand). Results Extracts from natural rubber latex condom brands A1 and A2, at concentrations of 100% and 50%, exhibited significant cytotoxicity, with optical density (OD) values being significantly lower than those of the blank control group and the polyurethane condom brands B1 and B2 (P<0.01). There was no significant difference in cell morphology and OD values between the extracts of B1 and B2 and the blank control group (P>0.05). Vaginal congestion was found in 3 rabbits from A1 group and 1 rabbit from the A2 group, while no obvious congestion was noted in rabbits from the B1 and the B2 groups. Histopathological examination showed scattered inflammatory cell infiltration in the vaginal tissue of 3 rabbits from the A1 group and 2 rabbits from the A2 group, and slight congestion in the blood vessels of the lamina propria. No obvious pathological changes were observed in the vaginal tissue of polyurethane brand rabbits. Two rabbits from the A1 group and 1 rabbit from the A2 group showed transient and mild erythema on the penis during the experiment. Histopathological examination showed that 1 rabbit from A1 group had small foci of pericapillary lymphocytes in the dermis of the penis, while no significant pathological changes were observed in the penile tissue of A2, B1, and B2 groups. After 30 days of continuous vaginal perfusion with condom extract, 3 rats in A1 group and 2 rats in the A2 group had uterine congestion, with the degree of congestion being lower in the A2 group. No significant congestion or pathological changes were observed in the vaginal and penile tissues of rabbits, or in the uterine tissues of rats from the polyurethane groups. None of the 4 groups of guinea pigs showed significant skin allergic reactions to the condom extracts. Conclusion Significant differences in biosafety exist among condoms of various materials and brands. To ensure product safety, it is crucial to strengthen quality control and regulatory oversight after condoms become commercially available.
Collapse
Affiliation(s)
- 漫 殷
- 成都上锦南府医院/四川大学华西医院上锦医院 麻醉手术中心 (成都 611730)Anesthesia and Surgery Center, Shangjin Nanfu Hospital/Shangjin Hospital, West China Hospital, Sichuan University, Chengdu 611730, China
| | - 曌曦 邓
- 成都上锦南府医院/四川大学华西医院上锦医院 麻醉手术中心 (成都 611730)Anesthesia and Surgery Center, Shangjin Nanfu Hospital/Shangjin Hospital, West China Hospital, Sichuan University, Chengdu 611730, China
| | - 娅莉 苗
- 成都上锦南府医院/四川大学华西医院上锦医院 麻醉手术中心 (成都 611730)Anesthesia and Surgery Center, Shangjin Nanfu Hospital/Shangjin Hospital, West China Hospital, Sichuan University, Chengdu 611730, China
| | - 晓梅 张
- 成都上锦南府医院/四川大学华西医院上锦医院 麻醉手术中心 (成都 611730)Anesthesia and Surgery Center, Shangjin Nanfu Hospital/Shangjin Hospital, West China Hospital, Sichuan University, Chengdu 611730, China
| |
Collapse
|
2
|
Rolińska K, Bakhshi H, Balk M, Parzuchowski P, Mazurek-Budzyńska M. Influence of the hard segments content on the properties of electrospun aliphatic poly(carbonate-urethane-urea)s. RSC Adv 2024; 14:15766-15775. [PMID: 38752158 PMCID: PMC11094699 DOI: 10.1039/d4ra01726a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Accepted: 05/02/2024] [Indexed: 05/18/2024] Open
Abstract
The study investigated the impact of hard segments (HS) content on the morphology and thermomechanical properties of electrospun aliphatic poly(carbonate-urea-urethane)s (PCUUs). The obtained nonwovens exhibited surface porosity ranging from 50% to 57%, and fiber diameters between 0.59 and 0.71 μm. Notably, the PCUUs nonwovens with the highest HS content (18%) displayed superior mechanical properties compared to those with lower HS contents. This study highlights the ability to customize the properties of polymeric nonwovens based on their chemical compositions, offering tailored solutions for specific application needs.
Collapse
Affiliation(s)
- Karolina Rolińska
- Faculty of Chemistry, Warsaw University of Technology Noakowskiego 3 00-664 Warsaw Poland
- Faculty of Chemistry, University of Warsaw Pasteura 1 02-093 Warsaw Poland
- Łukasiewicz Research Network - Industrial Chemistry Institute Rydygiera 8 01-793 Warsaw Poland
| | - Hadi Bakhshi
- Department of Life Science and Bioprocesses, Fraunhofer Institute for Applied Polymer Research IAP Geiselbergstraße 69 14476 Potsdam Germany
| | - Maria Balk
- Institute of Active Polymers, Helmholtz-Zentrum Hereon Kantstraße 55 14513 Teltow Germany
| | - Paweł Parzuchowski
- Faculty of Chemistry, Warsaw University of Technology Noakowskiego 3 00-664 Warsaw Poland
| | | |
Collapse
|
3
|
Ciobotaru V, Batistella M, De Oliveira Emmer E, Clari L, Masson A, Decante B, Le Bret E, Lopez-Cuesta JM, Hascoet S. Aortic Valve Engineering Advancements: Precision Tuning with Laser Sintering Additive Manufacturing of TPU/TPE Submillimeter Membranes. Polymers (Basel) 2024; 16:900. [PMID: 38611158 PMCID: PMC11013727 DOI: 10.3390/polym16070900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 03/12/2024] [Accepted: 03/19/2024] [Indexed: 04/14/2024] Open
Abstract
Synthetic biomaterials play a crucial role in developing tissue-engineered heart valves (TEHVs) due to their versatile mechanical properties. Achieving the right balance between mechanical strength and manufacturability is essential. Thermoplastic polyurethanes (TPUs) and elastomers (TPEs) garner significant attention for TEHV applications due to their notable stability, fatigue resistance, and customizable properties such as shear strength and elasticity. This study explores the additive manufacturing technique of selective laser sintering (SLS) for TPUs and TPEs to optimize process parameters to balance flexibility and strength, mimicking aortic valve tissue properties. Additionally, it aims to assess the feasibility of printing aortic valve models with submillimeter membranes. The results demonstrate that the SLS-TPU/TPE technique can produce micrometric valve structures with soft shape memory properties, resembling aortic tissue in strength, flexibility, and fineness. These models show promise for surgical training and manipulation, display intriguing echogenicity properties, and can potentially be personalized to shape biocompatible valve substitutes.
Collapse
Affiliation(s)
- Vlad Ciobotaru
- Centre Hospitalier Universitaire de Nîmes, Service de Radiologie, Imagerie Cardiovasculaire, 4 Rue du Professeur Robert Debré, 30900 Nîmes, France
- Hôpital Marie Lannelongue, Groupe Hospitalier Paris Saint Joseph, Faculté de Médecine Paris-Saclay, Université Paris-Saclay, Inserm UMR-S 999, BME Lab, 133 Avenue de la Résistance, 92350 Le Plessis Robinson, France; (B.D.); (E.L.B.); (S.H.)
- 3DHeartModeling, 30132 Caissargues, France
| | - Marcos Batistella
- Polymers Composites and Hybrids Department, IMT Mines Alès, 30319 Ales, France; (M.B.); (E.D.O.E.); (L.C.); (A.M.); (J.-M.L.-C.)
| | - Emily De Oliveira Emmer
- Polymers Composites and Hybrids Department, IMT Mines Alès, 30319 Ales, France; (M.B.); (E.D.O.E.); (L.C.); (A.M.); (J.-M.L.-C.)
| | - Louis Clari
- Polymers Composites and Hybrids Department, IMT Mines Alès, 30319 Ales, France; (M.B.); (E.D.O.E.); (L.C.); (A.M.); (J.-M.L.-C.)
| | - Arthur Masson
- Polymers Composites and Hybrids Department, IMT Mines Alès, 30319 Ales, France; (M.B.); (E.D.O.E.); (L.C.); (A.M.); (J.-M.L.-C.)
| | - Benoit Decante
- Hôpital Marie Lannelongue, Groupe Hospitalier Paris Saint Joseph, Faculté de Médecine Paris-Saclay, Université Paris-Saclay, Inserm UMR-S 999, BME Lab, 133 Avenue de la Résistance, 92350 Le Plessis Robinson, France; (B.D.); (E.L.B.); (S.H.)
| | - Emmanuel Le Bret
- Hôpital Marie Lannelongue, Groupe Hospitalier Paris Saint Joseph, Faculté de Médecine Paris-Saclay, Université Paris-Saclay, Inserm UMR-S 999, BME Lab, 133 Avenue de la Résistance, 92350 Le Plessis Robinson, France; (B.D.); (E.L.B.); (S.H.)
| | - José-Marie Lopez-Cuesta
- Polymers Composites and Hybrids Department, IMT Mines Alès, 30319 Ales, France; (M.B.); (E.D.O.E.); (L.C.); (A.M.); (J.-M.L.-C.)
| | - Sebastien Hascoet
- Hôpital Marie Lannelongue, Groupe Hospitalier Paris Saint Joseph, Faculté de Médecine Paris-Saclay, Université Paris-Saclay, Inserm UMR-S 999, BME Lab, 133 Avenue de la Résistance, 92350 Le Plessis Robinson, France; (B.D.); (E.L.B.); (S.H.)
| |
Collapse
|
4
|
Bhattacharjee A, Savargaonkar AV, Tahir M, Sionkowska A, Popat KC. Surface modification strategies for improved hemocompatibility of polymeric materials: a comprehensive review. RSC Adv 2024; 14:7440-7458. [PMID: 38433935 PMCID: PMC10906639 DOI: 10.1039/d3ra08738g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 02/22/2024] [Indexed: 03/05/2024] Open
Abstract
Polymeric biomaterials are a widely used class of materials due to their versatile properties. However, as with all other types of materials used for biomaterials, polymers also have to interact with blood. When blood comes into contact with any foreign body, it initiates a cascade which leads to platelet activation and blood coagulation. The implant surface also has to encounter a thromboinflammatory response which makes the implant integrity vulnerable, this leads to blood coagulation on the implant and obstructs it from performing its function. Hence, the surface plays a pivotal role in the design and application of biomaterials. In particular, the surface properties of biomaterials are responsible for biocompatibility with biological systems and hemocompatibility. This review provides a report on recent advances in the field of surface modification approaches for improved hemocompatibility. We focus on the surface properties of polysaccharides, proteins, and synthetic polymers. The blood coagulation cascade has been discussed and blood - material surface interactions have also been explained. The interactions of blood proteins and cells with polymeric material surfaces have been discussed. Moreover, the benefits as well as drawbacks of blood coagulation on the implant surface for wound healing purposes have also been studied. Surface modifications implemented by other researchers to enhance as well as prevent blood coagulation have also been analyzed.
Collapse
Affiliation(s)
- Abhishek Bhattacharjee
- School of Advanced Material Discovery, Colorado State University Fort Collins CO 80523 USA
| | | | - Muhammad Tahir
- Department of Biomaterials and Cosmetic Chemistry, Faculty of Chemistry, Nicolaus Copernicus University Gagarina 7 87-100 Torun Poland
| | - Alina Sionkowska
- Department of Biomaterials and Cosmetic Chemistry, Faculty of Chemistry, Nicolaus Copernicus University Gagarina 7 87-100 Torun Poland
| | - Ketul C Popat
- School of Advanced Material Discovery, Colorado State University Fort Collins CO 80523 USA
- Department of Mechanical Engineering, Colorado State University Fort Collins CO 80523 USA
- Department of Bioengineering, George Mason University Fairfax VA 22030 USA
| |
Collapse
|
5
|
Drożdż K, Gołda-Cępa M, Chytrosz-Wróbel P, Kotarba A, Brzychczy-Włoch M. Improving Biocompatibility of Polyurethanes Apply in Medicine Using Oxygen Plasma and Its Negative Effect on Increased Bacterial Adhesion. Int J Biomater 2024; 2024:5102603. [PMID: 38434098 PMCID: PMC10907100 DOI: 10.1155/2024/5102603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 02/09/2024] [Accepted: 02/12/2024] [Indexed: 03/05/2024] Open
Abstract
Polyurethanes (PUs) are versatile polymers used in medical applications due to their high flexibility and fatigue resistance. PUs are widely used for synthetic blood vessels, wound dressings, cannulas, and urinary and cardiovascular catheters. Many scientific reports indicate that surface wettability is crucial for biocompatibility and bacterial adhesion. The use of oxygen plasma to modify PUs is advantageous because of its effectiveness in introducing oxygen-containing functional groups, thereby altering surface wettability. The purpose of this study was to investigate the effect of the modification of the oxygen plasma of polyurethane on its biocompatibility with lung tissue (A549 cell line) and the adhesion of Gram-positive bacteria (S. aureus and S. epidermidis). The results showed that the modification of polyurethane by oxygen plasma allowed the introduction of functional groups containing oxygen (-OH and -COOH), which significantly increased its hydrophilicity (change from 105° ± 2° to 9° ± 2°) of PUs. Surface analysis by atomic force microscopy (AFM) showed changes in PU topography (change in maximum height from ∼110.3 nm to ∼32.1 nm). Moreover, biocompatibility studies on A549 cells showed that on the PU-modified surface, the cells exhibited altered morphology (increases in cell surface area and length, and thus reduced circularity) without concomitant effects on cell viability. However, serial dilution and plate count and microscopic methods confirmed that plasma modification significantly increased the adhesion of S. aureus and S. epidermidis bacteria. This study indicate the important role of surface hydrophilicity in biocompatibility and bacterial adhesion, which is important in the design of new medical biomaterials.
Collapse
Affiliation(s)
- Kamil Drożdż
- Department of Molecular Medical Microbiology, Chair of Microbiology, Faculty of Medicine, Jagiellonian University Medical College, Krakow 31-121, Poland
| | - Monika Gołda-Cępa
- Faculty of Chemistry, Jagiellonian University, Krakow 31-007, Poland
| | | | - Andrzej Kotarba
- Faculty of Chemistry, Jagiellonian University, Krakow 31-007, Poland
| | - Monika Brzychczy-Włoch
- Department of Molecular Medical Microbiology, Chair of Microbiology, Faculty of Medicine, Jagiellonian University Medical College, Krakow 31-121, Poland
| |
Collapse
|
6
|
Wang H, Huddleston S, Yang J, Ameer GA. Enabling Proregenerative Medical Devices via Citrate-Based Biomaterials: Transitioning from Inert to Regenerative Biomaterials. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2306326. [PMID: 38043945 DOI: 10.1002/adma.202306326] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 10/03/2023] [Indexed: 12/05/2023]
Abstract
Regenerative medicine aims to restore tissue and organ function without the use of prosthetics and permanent implants. However, achieving this goal has been elusive, and the field remains mostly an academic discipline with few products widely used in clinical practice. From a materials science perspective, barriers include the lack of proregenerative biomaterials, a complex regulatory process to demonstrate safety and efficacy, and user adoption challenges. Although biomaterials, particularly biodegradable polymers, can play a major role in regenerative medicine, their suboptimal mechanical and degradation properties often limit their use, and they do not support inherent biological processes that facilitate tissue regeneration. As of 2020, nine synthetic biodegradable polymers used in medical devices are cleared or approved for use in the United States of America. Despite the limitations in the design, production, and marketing of these devices, this small number of biodegradable polymers has dominated the resorbable medical device market for the past 50 years. This perspective will review the history and applications of biodegradable polymers used in medical devices, highlight the need and requirements for regenerative biomaterials, and discuss the path behind the recent successful introduction of citrate-based biomaterials for manufacturing innovative medical products aimed at improving the outcome of musculoskeletal surgeries.
Collapse
Affiliation(s)
- Huifeng Wang
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
- Center for Advanced Regenerative Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Samantha Huddleston
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
- Center for Advanced Regenerative Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Jian Yang
- Biomedical Engineering Program, School of Engineering, Westlake University, Hangzhou, Zhejiang, 310030, China
- Research Center for Industries of the Future, Westlake University, Hangzhou, Zhejiang, 310030, China
| | - Guillermo A Ameer
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
- Center for Advanced Regenerative Engineering, Northwestern University, Evanston, IL, 60208, USA
- Department of Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
- Chemistry of Life Processes Institute, Northwestern University, Evanston, IL, 60208, USA
- Simpson Querrey Institute, Northwestern University, Chicago, IL, 60611, USA
- International Institute for Nanotechnology, Northwestern University, Evanston, IL, 60208, USA
| |
Collapse
|
7
|
Gidaro A, Quici M, Giustivi D, Pinelli F, Samartin F, Casella F, Cogliati C, Rizzi G, Salvi E, Bartoli A, Foschi A, Castelli R, Calloni M, Gemma M. Integrated short peripheral intravenous cannulas and risk of catheter failure: A systematic review and meta-analysis. J Vasc Access 2024:11297298231218468. [PMID: 38166435 DOI: 10.1177/11297298231218468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2024] Open
Abstract
BACKGROUND Short peripheral catheters (SPCs) are used to provide intravenous therapies in hospitalized patients. Recently, the category of SPC has become more complex, with the introduction in clinical practice of "integrated" SPCs (ISPCs), renewed regarding the material (polyurethane rather than polytetrafluoroethylene) and design (large wing; pre-assembled extension; preassembled needle-free connector (NFC)). METHODS This systematic review and meta-analysis aimed to analyze randomized controlled trials (RCTs) and quasi-randomized studies in hospitalized patients, analyzing the risk of overall catheter failure as well as the risk of each type of complication (occlusion, infiltration, thrombophlebitis, and dislodgement) for ISPCs compared to non-integrated SPCs. These systematic review and meta-analysis were registered on PROSPERO (CRD42022322970). DATA SOURCES We searched PUBMED®, EMBASE®, and the Cochrane Controlled Clinical Trials register from April to November 2022. RESULTS: INCLUDED STUDIES The research identified 1260 articles. After the abstract review, 13 studies were included for full manuscript review and, after that, six papers (4727 patients) were included in the meta-analysis. DESCRIPTION OF THE EFFECT We found a significantly reduced risk of catheter failure (pooling all complications) for ISPCs compared to SPCs (p = 0.002 RR 0.65; 95% CI 0.63-0.9). A significant reduction in the risks of occlusion (p = 0.007 RR 0.72; 95% CI 0.56-0.92) was observed. As regards the risk of infiltration, thrombophlebitis, and dislodgement, the analysis showed a trend in favor of ISPCs, though not statistically significant (respectively p = 0.2 RR 0.84; 95% CI 0.64-1.1; p = 0.25 RR 0.91; 95% CI 0.78-1.07; p = 0.06 RR 0.72; 95% CI 0.52-1.01). CONCLUSIONS ISPCs significantly reduce the risks of catheter failure (overall complications) and occlusion. More RCTs are needed to understand if the preassembled ISPC is better than the composted closed system (non-integrated SPC + extension line + NFC).
Collapse
Affiliation(s)
- Antonio Gidaro
- Department of Biomedical and Clinical Sciences "Luigi Sacco," University of Milan, Luigi Sacco Hospital, Milan, Italy
| | - Massimiliano Quici
- Department of Biomedical and Clinical Sciences "Luigi Sacco," University of Milan, Luigi Sacco Hospital, Milan, Italy
| | | | - Fulvio Pinelli
- Department of Infectious Diseases, Luigi Sacco Hospital, Milan, Italy
| | - Federica Samartin
- Department of Biomedical and Clinical Sciences "Luigi Sacco," University of Milan, Luigi Sacco Hospital, Milan, Italy
| | - Francesco Casella
- Department of Biomedical and Clinical Sciences "Luigi Sacco," University of Milan, Luigi Sacco Hospital, Milan, Italy
| | - Chiara Cogliati
- Department of Biomedical and Clinical Sciences "Luigi Sacco," University of Milan, Luigi Sacco Hospital, Milan, Italy
| | - Giulia Rizzi
- Department of Biomedical and Clinical Sciences "Luigi Sacco," University of Milan, Luigi Sacco Hospital, Milan, Italy
| | - Emanuele Salvi
- Department of Biomedical and Clinical Sciences "Luigi Sacco," University of Milan, Luigi Sacco Hospital, Milan, Italy
| | - Arianna Bartoli
- Department of Biomedical and Clinical Sciences "Luigi Sacco," University of Milan, Luigi Sacco Hospital, Milan, Italy
| | - Antonella Foschi
- Department of Infectious Diseases, Luigi Sacco Hospital, Milan, Italy
| | - Roberto Castelli
- Department of Medicine, Surgery and Pharmacy, University of Sassari, Sassari, Italy
| | - Maria Calloni
- Department of Biomedical and Clinical Sciences "Luigi Sacco," University of Milan, Luigi Sacco Hospital, Milan, Italy
| | - Marco Gemma
- UOC Intensive Care Unit-Neuroanesthesia and Reanimation IRCCS Carlo Besta Neurological Institute Foundation, Milan, Italy
| |
Collapse
|
8
|
Betancur MI, Case A, Ilich E, Mehta N, Meehan S, Pogrebivsky S, Keir ST, Stevenson K, Brahma B, Gregory S, Chen W, Ashley DM, Bellamkonda R, Mokarram N. A neural tract-inspired conduit for facile, on-demand biopsy of glioblastoma. Neurooncol Adv 2024; 6:vdae064. [PMID: 38813113 PMCID: PMC11135361 DOI: 10.1093/noajnl/vdae064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2024] Open
Abstract
Background A major hurdle to effectively treating glioblastoma (GBM) patients is the lack of longitudinal information about tumor progression, evolution, and treatment response. Methods In this study, we report the use of a neural tract-inspired conduit containing aligned polymeric nanofibers (i.e., an aligned nanofiber device) to enable on-demand access to GBM tumors in 2 rodent models. Depending on the experiment, a humanized U87MG xenograft and/or F98-GFP+ syngeneic rat tumor model was chosen to test the safety and functionality of the device in providing continuous sampling access to the tumor and its microenvironment. Results The aligned nanofiber device was safe and provided a high quantity of quality genomic materials suitable for omics analyses and yielded a sufficient number of live cells for in vitro expansion and screening. Transcriptomic and genomic analyses demonstrated continuity between material extracted from the device and that of the primary, intracortical tumor (in the in vivo model). Conclusions The results establish the potential of this neural tract-inspired, aligned nanofiber device as an on-demand, safe, and minimally invasive access point, thus enabling rapid, high-throughput, longitudinal assessment of tumor and its microenvironment, ultimately leading to more informed clinical treatment strategies.
Collapse
Affiliation(s)
| | - Ayden Case
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Ekaterina Ilich
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Nalini Mehta
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Sean Meehan
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Sabrina Pogrebivsky
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Stephen T Keir
- Department of Neurosurgery, Duke University, Durham, North Carolina, USA
| | - Kevin Stevenson
- Molecular Physiology Institute, Duke University, Durham, North Carolina, USA
| | - Barun Brahma
- Department of Neurosurgery, Emory University, Atlanta, Georgia, USA
| | - Simon Gregory
- Molecular Physiology Institute, Duke University, Durham, North Carolina, USA
| | - Wei Chen
- Center for Genomic and Computational Biology, Duke University, Durham, Georgia, USA
| | - David M Ashley
- Department of Neurosurgery, Duke University, Durham, North Carolina, USA
| | - Ravi Bellamkonda
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
- Department of Biology, Emory University, Atlanta, Georgia, USA
| | - Nassir Mokarram
- Department of Neurosurgery, Emory University, Atlanta, Georgia, USA
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| |
Collapse
|
9
|
Zhou H, Wu Q, Wu L, Zhao Y. In vitro hemodynamics of fabric composite membrane for cardiac valve prosthesis replacement. J Biomech 2024; 163:111956. [PMID: 38266534 DOI: 10.1016/j.jbiomech.2024.111956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 01/08/2024] [Accepted: 01/15/2024] [Indexed: 01/26/2024]
Abstract
This study aimed to investigate the hemodynamics of a novel fabric composite that can be used as a substitute for bovine pericardium. The structure is composed of ultrahigh molecular weight polyethylene (UHMWPE) fabric coated with thermoplastic polyurethane (TPU) membranes on both sides. In vitro experiments were carried out on two composite valve samples with different specifications and a bovine pericardial one with the same dimension and structure. Hemodynamic properties including the effective orifice area (EOA) and regurgitant fraction (RF) were obtained and compared through pulsatile-flow testing in a pulse duplicator. Using the particle image velocimetry (PIV) technique, frames of the downstream velocity field in the aortic valve chamber were captured during cardiac cycles. Then, the field of Reynolds shear stress (RSS), viscous shear stress (VSS), and turbulent kinetic energy (TKE) at peak systole were calculated. A fluid-structure interaction (FSI) model has also been used to verify the pulsatile-flow testing. Compared with the bovine pericardial valve, composite valves have nosuperiority regarding EOA and RF due to their slightly higher rigidity. However, shear stresses of composite valves were lower than those of the bovine pericardial valve indicating more stable blood flows, which means that composite leaflets have the potential to reduce the risks of thrombosis and hemolysis induced by the mechanical contact between the blood flow and leaflets of valve prostheses.
Collapse
Affiliation(s)
- Han Zhou
- Center for Composite Materials, Harbin Institute of Technology, Harbin 150001, China; National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, Harbin 150001, China
| | - Qianqian Wu
- Center for Composite Materials, Harbin Institute of Technology, Harbin 150001, China; National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, Harbin 150001, China.
| | - Linzhi Wu
- Center for Composite Materials, Harbin Institute of Technology, Harbin 150001, China; National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, Harbin 150001, China; Key Laboratory of Advanced Ship Materials and Mechanics, Harbin Engineering University, Harbin 150001, China
| | - Yang Zhao
- Center for Composite Materials, Harbin Institute of Technology, Harbin 150001, China; National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, Harbin 150001, China
| |
Collapse
|
10
|
Rolińska K, Bakhshi H, Balk M, Blocki A, Panwar A, Puchalski M, Wojasiński M, Mazurek-Budzyńska M. Electrospun Poly(carbonate-urea-urethane)s Nonwovens with Shape-Memory Properties as a Potential Biomaterial. ACS Biomater Sci Eng 2023; 9:6683-6697. [PMID: 38032398 PMCID: PMC10716822 DOI: 10.1021/acsbiomaterials.3c01214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 11/08/2023] [Accepted: 11/09/2023] [Indexed: 12/01/2023]
Abstract
Poly(carbonate-urea-urethane) (PCUU)-based scaffolds exhibit various desirable properties for tissue engineering applications. This study thus aimed to investigate the suitability of PCUU as polymers for the manufacturing of nonwoven mats by electrospinning, able to closely mimic the fibrous structure of the extracellular matrix. PCUU nonwovens of fiber diameters ranging from 0.28 ± 0.07 to 0.82 ± 0.12 μm were obtained with an average surface porosity of around 50-60%. Depending on the collector type and solution concentration, a broad range of tensile strengths (in the range of 0.3-9.6 MPa), elongation at break (90-290%), and Young's modulus (5.7-26.7 MPa) at room temperature of the nonwovens could be obtained. Furthermore, samples collected on the plate collector showed a shape-memory effect with a shape-recovery ratio (Rr) of around 99% and a shape-fixity ratio (Rf) of around 96%. Biological evaluation validated the inertness, stability, and lack of cytotoxicity of PCUU nonwovens obtained on the plate collector. The ability of mesenchymal stem cells (MSCs) and endothelial cells (HUVECs) to attach, elongate, and grow on the surface of the nonwovens suggests that the manufactured nonwovens are suitable scaffolds for tissue engineering applications.
Collapse
Affiliation(s)
- Karolina Rolińska
- Faculty
of Chemistry, Warsaw University of Technology, Noakowskiego 3, 00-664 Warsaw, Poland
- Faculty
of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
| | - Hadi Bakhshi
- Department
of Life Science and Bioprocesses, Fraunhofer
Institute for Applied Polymer Research IAP, Geiselbergstraße 69, 14476 Potsdam, Germany
| | - Maria Balk
- Institute
of Active Polymers, Helmholtz-Zentrum Hereon, Kantstraße 55, 14513 Teltow, Germany
| | - Anna Blocki
- Institute
for Tissue Engineering and Regenerative Medicine, The Chinese University
of Hong Kong, Shatin, New Territories 999077, Hong Kong
- School of
Biomedical Sciences, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, New Territories 999077, Hong Kong
- Center
for Neuromusculoskeletal Restorative Medicine, The Chinese University of Hong Kong, Shatin, New Territories 999077, Hong Kong
| | - Amit Panwar
- Institute
for Tissue Engineering and Regenerative Medicine, The Chinese University
of Hong Kong, Shatin, New Territories 999077, Hong Kong
- School of
Biomedical Sciences, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, New Territories 999077, Hong Kong
- Center
for Neuromusculoskeletal Restorative Medicine, The Chinese University of Hong Kong, Shatin, New Territories 999077, Hong Kong
| | - Michał Puchalski
- Institute
of Material Science of Textiles and Polymer Composites, Faculty of
Material Technologies and Textile Design, Lodz University of Technology, ul. Żeromskiego 116, 90-924 Łódź, Poland
| | - Michał Wojasiński
- Faculty
of Chemical and Process Engineering, Department of Biotechnology and
Bioprocess Engineering, Laboratory of Biomedical Engineering, Warsaw University of Technology, Waryńskiego 1, 00-645 Warsaw, Poland
| | | |
Collapse
|
11
|
Dimitrova M, Vlahova A, Kalachev Y, Zlatev S, Kazakova R, Capodiferro S. Recent Advances in 3D Printing of Polymers for Application in Prosthodontics. Polymers (Basel) 2023; 15:4525. [PMID: 38231950 PMCID: PMC10708542 DOI: 10.3390/polym15234525] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 11/15/2023] [Accepted: 11/22/2023] [Indexed: 01/19/2024] Open
Abstract
Contemporary mass media frequently depict 3D printing as a technology with widespread utilization in the creation of dental prosthetics. This paper endeavors to provide an evidence-based assessment of the current scope of 3D printing's integration within dental laboratories and practices. Its primary objective is to offer a systematic evaluation of the existing applications of 3D-printing technology within the realm of dental prosthetic restorations. Furthermore, this article delves into potential prospects, while also critically examining the sustained relevance of conventional dental laboratory services and manufacturing procedures. The central focus of this article is to expound upon the extent to which 3D printing is presently harnessed for crafting dental prosthetic appliances. By presenting verifiable data and factual insights, this article aspires to elucidate the actual implementation of 3D printing in prosthetic dentistry and its seamless integration into dental practices. The aim of this narrative review is twofold: firstly, to provide an informed and unbiased evaluation of the role that 3D printing currently plays within dental laboratories and practices; and secondly, to instigate contemplation on the transformative potential of this technology, both in terms of its contemporary impact and its future implications, while maintaining a balanced consideration of traditional dental approaches.
Collapse
Affiliation(s)
- Mariya Dimitrova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
| | - Angelina Vlahova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Yavor Kalachev
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
| | - Stefan Zlatev
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Rada Kazakova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Saverio Capodiferro
- Department of Interdisciplinary Medicine, Aldo Moro, University of Bari, 70100 Bari, Italy;
| |
Collapse
|
12
|
Borcan F, Vlase T, Vlase G, Popescu R, Soica CM. The Influence of an Isocyanate Structure on a Polyurethane Delivery System for 2'-Deoxycytidine-5'-monophosphate. J Funct Biomater 2023; 14:526. [PMID: 37888191 PMCID: PMC10607123 DOI: 10.3390/jfb14100526] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/16/2023] [Accepted: 10/17/2023] [Indexed: 10/28/2023] Open
Abstract
The delivery of nucleosides represents an interesting research trend in recent years due to their application in various viral infections. The main aims of this study were to develop and to characterize polyurethane particles that are intended to be used for the transport of nucleosides. Three samples have been prepared using aliphatic diisocyanates, a mixture of polyethylene glycol, polycaprolactone, and diols, respectively. The samples were characterized through refractivity measurements, drug loading efficacy, release and penetration rate investigations, FTIR and Raman spectroscopy, thermal analyses, Zetasizer, SEM, HDFa cells viability, and irritation tests on mice skin. The results indicate the obtaining of particles with sizes between 132 and 190 nm, positive Zeta potential values (28.3-31.5 mV), and a refractivity index around 1.60. A good thermal stability was found, and SEM images show a medium tendency to agglomerate. The samples' color, pH, and electrical conductivity have changed only to a small extent over time, and the evaluations indicate an almost 70% encapsulation efficacy, a prolonged release, and that around 70% of particles have penetrated an artificial membrane in the first 24 h. The synthesized products should be tested in further clinical trials, and the current tests on cell cultures and mice skin revealed no side effects.
Collapse
Affiliation(s)
- Florin Borcan
- Department I, Advanced Instrumental Screening Center, Faculty of Pharmacy, “Victor Babes” University of Medicine and Pharmacy, 2 E. Murgu Sq., 300041 Timisoara, Romania
| | - Titus Vlase
- Research Center “Thermal Analysis in Environmental Problems”, Faculty of Chemistry, Biology, Geography, West University of Timisoara, 16 Pestalozzi Str., 300115 Timisoara, Romania; (T.V.); (G.V.)
| | - Gabriela Vlase
- Research Center “Thermal Analysis in Environmental Problems”, Faculty of Chemistry, Biology, Geography, West University of Timisoara, 16 Pestalozzi Str., 300115 Timisoara, Romania; (T.V.); (G.V.)
| | - Roxana Popescu
- Department II, Faculty of Medicine, “Victor Babes” University of Medicine and Pharmacy, 14A T. Vladimirescu Str., 300041 Timisoara, Romania;
| | - Codruta M. Soica
- Department II, Faculty of Pharmacy, “Victor Babes” University of Medicine and Pharmacy, 2 E. Murgu Sq., 300041 Timisoara, Romania;
| |
Collapse
|
13
|
Grzęda D, Węgrzyk G, Nowak A, Idaszek J, Szczepkowski L, Ryszkowska J. Cytotoxic Properties of Polyurethane Foams for Biomedical Applications as a Function of Isocyanate Index. Polymers (Basel) 2023; 15:2754. [PMID: 37376400 DOI: 10.3390/polym15122754] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 06/04/2023] [Accepted: 06/14/2023] [Indexed: 06/29/2023] Open
Abstract
Polyurethane foams are widely used in biomedical applications due to their desirable mechanical properties and biocompatibility. However, the cytotoxicity of its raw materials can limit their use in certain applications. In this study, a group of open-cell polyurethane foams were investigated for their cytotoxic properties as a function of the isocyanate index, a critical parameter in the synthesis of polyurethanes. The foams were synthesized using a variety of isocyanate indices and characterized for their chemical structure and cytotoxicity. This study indicates that the isocyanate index highly influences the chemical structure of polyurethane foams, also causing changes in cytotoxicity. These findings have important implications for designing and using polyurethane foams as composite matrices in biomedical applications, as careful consideration of the isocyanate index is necessary to ensure biocompatibility.
Collapse
Affiliation(s)
- Dominik Grzęda
- Faculty of Materials Science and Engineering, Warsaw University of Technology, Wołoska 141, 02-507 Warsaw, Poland
| | - Grzegorz Węgrzyk
- Faculty of Materials Science and Engineering, Warsaw University of Technology, Wołoska 141, 02-507 Warsaw, Poland
| | - Adriana Nowak
- Department of Environmental Biotechnology, Lodz University of Technology, Wolczanska 171/173, 90-530 Lodz, Poland
| | - Joanna Idaszek
- Faculty of Materials Science and Engineering, Warsaw University of Technology, Wołoska 141, 02-507 Warsaw, Poland
| | | | - Joanna Ryszkowska
- Faculty of Materials Science and Engineering, Warsaw University of Technology, Wołoska 141, 02-507 Warsaw, Poland
| |
Collapse
|
14
|
Zhou H, Wu Q, Wu L, Zhao Y. Mechanical behaviors of high-strength fabric composite membrane designed for cardiac valve prosthesis replacement. J Mech Behav Biomed Mater 2023; 142:105863. [PMID: 37116312 DOI: 10.1016/j.jmbbm.2023.105863] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 04/15/2023] [Accepted: 04/16/2023] [Indexed: 04/30/2023]
Abstract
Bovine pericardium has been commonly used as leaflets in cardiac valve prosthesis replacement for decades because of its good short-term hemocompatibility and hemodynamic performance. However, fatigue, abrasion, permanent deformation, calcification, and many other failure modes have been reported as well. The degradation of the performance will have a serious impact on the function of valve prostheses, posing a risk to the patient's health. This study aimed to introduce a flexible fabric composite with better mechanical performance such that it can be employed as a substitute material for bioprosthetic valve leaflets. This composite has a multilayered thin film structure made of ultrahigh molecular weight polyethylene (UHMWPE) fabric and thermoplastic polyurethane (TPU) membranes. The mechanical properties of three specifications with different design parameters were tested. The tensile strength, shear behavior, tear resistance, and bending stiffness of the composites were characterized and compared to those of bovine pericardium. A constitutive model was also established to describe the composites' mechanical behaviors and predict their strength. According to the results of the tests, the composite could maintain a flexible bending stiffness with high in-plane tensile strength and tear strength. Therefore, bioprosthetic valve made of this substitute material can withstand harsher loads in the blood flow environment than those made of bovine pericardium. Moreover, all these test results and constitutive models can be used in future research to evaluate hemodynamic performance and clinical applications of fabric composite valve prostheses.
Collapse
Affiliation(s)
- Han Zhou
- Center for Composite Materials, Harbin Institute of Technology, Harbin, 150001, China; National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, Harbin, 150001, China
| | - Qianqian Wu
- Center for Composite Materials, Harbin Institute of Technology, Harbin, 150001, China; National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, Harbin, 150001, China.
| | - Linzhi Wu
- Center for Composite Materials, Harbin Institute of Technology, Harbin, 150001, China; National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, Harbin, 150001, China; Key Laboratory of Advanced Ship Materials and Mechanics, Harbin Engineering University, Harbin, 150001, China
| | - Yang Zhao
- Center for Composite Materials, Harbin Institute of Technology, Harbin, 150001, China; National Key Laboratory of Science and Technology on Advanced Composites in Special Environments, Harbin Institute of Technology, Harbin, 150001, China
| |
Collapse
|
15
|
Van Hecke M, Van Hoof L, Sikole M, Mufty H, Claus P, Verbrugghe P, Ely J, Berg GA, Roskams T, Meuris B. A Large-Diameter Vascular Graft Replacing Animal-Derived Sealants With an Elastomeric Polymer. J Surg Res 2023; 284:6-16. [PMID: 36527768 DOI: 10.1016/j.jss.2022.11.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 10/25/2022] [Accepted: 11/20/2022] [Indexed: 12/16/2022]
Abstract
INTRODUCTION To assess the safety and efficacy of an experimental large-diameter vascular graft externally sealed with an elastomeric polymer when used as an interposition graft in the descending aorta of sheep. METHODS The experimental vascular grafts as well as control gelatin sealed interposition grafts were inserted into the descending aorta of juvenile sheep. The grafts were assessed by time to hemostasis and blood loss during surgery and hematology and biochemistry panels at distinct time points. Magnetic resonance imaging (MRI) was performed at 3 and at 6 mo after surgery, after which the animals were euthanized and necropsies were carried out including macroscopic and microscopic examination of the grafts, anastomoses, and distal organs. RESULTS All animals survived the study period. There was no perceivable difference in the surgical handling of the grafts. The median intraoperative blood loss was 27.5 mL (range 10.0-125.0 mL) in the experimental group and 50.0 mL (range 10.0-75.0 mL) in the control group. The median time to hemostasis was 5.0 min (range 2.0-16.0 min) minutes in the experimental group versus 6.0 min (range 4.0-6.0 min) in the control group. MRI showed normal flow and graft patency in both groups. Healing and perianastomotic endothelialization was similar in both groups. CONCLUSIONS The experimental graft has a similar safety and performance profile and largely comparable necropsy results, in comparison to a commonly used prosthetic vascular graft, with the experimental grafts eliciting a nonadherent external fibrous capsule as the major difference compared to the control grafts that were incorporated into the periadventitia. Survival, hemostatic sealing, and hematologic and radiologic results were comparable between the study groups.
Collapse
Affiliation(s)
- Manon Van Hecke
- Department of Pathology, University Hospitals Leuven, Leuven, Belgium.
| | - Lucas Van Hoof
- Department of Cardiac Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Magdalena Sikole
- Department of Cardiac Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Hozan Mufty
- Department of Vascular Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Piet Claus
- KU Leuven, Department of Cardiovascular Sciences, Cardiovascular Imaging and Dynamics, Leuven, Belgium
| | - Peter Verbrugghe
- Department of Cardiac Surgery, University Hospitals Leuven, Leuven, Belgium
| | - John Ely
- RUA Life Sciences, Irvine, United Kingdom
| | | | - Tania Roskams
- Department of Pathology, University Hospitals Leuven, Leuven, Belgium
| | - Bart Meuris
- Department of Cardiac Surgery, University Hospitals Leuven, Leuven, Belgium
| |
Collapse
|
16
|
Constantino VRL, Figueiredo MP, Magri VR, Eulálio D, Cunha VRR, Alcântara ACS, Perotti GF. Biomaterials Based on Organic Polymers and Layered Double Hydroxides Nanocomposites: Drug Delivery and Tissue Engineering. Pharmaceutics 2023; 15:pharmaceutics15020413. [PMID: 36839735 PMCID: PMC9961265 DOI: 10.3390/pharmaceutics15020413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 01/18/2023] [Accepted: 01/19/2023] [Indexed: 01/28/2023] Open
Abstract
The development of biomaterials has a substantial role in pharmaceutical and medical strategies for the enhancement of life quality. This review work focused on versatile biomaterials based on nanocomposites comprising organic polymers and a class of layered inorganic nanoparticles, aiming for drug delivery (oral, transdermal, and ocular delivery) and tissue engineering (skin and bone therapies). Layered double hydroxides (LDHs) are 2D nanomaterials that can intercalate anionic bioactive species between the layers. The layers can hold metal cations that confer intrinsic biological activity to LDHs as well as biocompatibility. The intercalation of bioactive species between the layers allows the formation of drug delivery systems with elevated loading capacity and modified release profiles promoted by ion exchange and/or solubilization. The capacity of tissue integration, antigenicity, and stimulation of collagen formation, among other beneficial characteristics of LDH, have been observed by in vivo assays. The association between the properties of biocompatible polymers and LDH-drug nanohybrids produces multifunctional nanocomposites compatible with living matter. Such nanocomposites are stimuli-responsive, show appropriate mechanical properties, and can be prepared by creative methods that allow a fine-tuning of drug release. They are processed in the end form of films, beads, gels, monoliths etc., to reach orientated therapeutic applications. Several studies attest to the higher performance of polymer/LDH-drug nanocomposite compared to the LDH-drug hybrid or the free drug.
Collapse
Affiliation(s)
- Vera Regina Leopoldo Constantino
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes 748, CEP 05513-970, São Paulo 05513-970, SP, Brazil
- Correspondence: ; Tel.: +55-11-3091-9152
| | - Mariana Pires Figueiredo
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes 748, CEP 05513-970, São Paulo 05513-970, SP, Brazil
| | - Vagner Roberto Magri
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes 748, CEP 05513-970, São Paulo 05513-970, SP, Brazil
| | - Denise Eulálio
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes 748, CEP 05513-970, São Paulo 05513-970, SP, Brazil
| | - Vanessa Roberta Rodrigues Cunha
- Instituto Federal de Educação, Ciência e Tecnologia de Mato Grosso (IFMT), Linha J, s/n–Zona Rural, Juína 78320-000, MT, Brazil
| | | | - Gustavo Frigi Perotti
- Instituto de Ciências Exatas e Tecnologia, Universidade Federal do Amazonas, Rua Nossa Senhora do Rosário, 3863, Itacoatiara 69103-128, AM, Brazil
| |
Collapse
|
17
|
Wang J, Dai D, Xie H, Li D, Xiong G, Zhang C. Biological Effects, Applications and Design Strategies of Medical Polyurethanes Modified by Nanomaterials. Int J Nanomedicine 2022; 17:6791-6819. [PMID: 36600880 PMCID: PMC9807071 DOI: 10.2147/ijn.s393207] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Accepted: 12/20/2022] [Indexed: 12/30/2022] Open
Abstract
Polyurethane (PU) has wide application and popularity as medical apparatus due to its unique structural properties relationship. However, there are still some problems with medical PUs, such as a lack of functionality, insufficient long-term implantation safety, undesired stability, etc. With the rapid development of nanotechnology, the nanomodification of medical PU provides new solutions to these clinical problems. The introduction of nanomaterials could optimize the biocompatibility, antibacterial effect, mechanical strength, and degradation of PUs via blending or surface modification, therefore expanding the application range of medical PUs. This review summarizes the current applications of nano-modified medical PUs in diverse fields. Furthermore, the underlying mechanisms in efficiency optimization are analyzed in terms of the enhanced biological and mechanical properties critical for medical use. We also conclude the preparation schemes and related parameters of nano-modified medical PUs, with discussions about the limitations and prospects. This review indicates the current status of nano-modified medical PUs and contributes to inspiring novel and appropriate designing of PUs for desired clinical requirements.
Collapse
Affiliation(s)
- Jianrong Wang
- Stomatological Hospital, Southern Medical University, Guangzhou, 510280, People’s Republic of China
| | - Danni Dai
- Stomatological Hospital, Southern Medical University, Guangzhou, 510280, People’s Republic of China
| | - Hanshu Xie
- Stomatological Hospital, Southern Medical University, Guangzhou, 510280, People’s Republic of China
| | - Dan Li
- Stomatological Hospital, Southern Medical University, Guangzhou, 510280, People’s Republic of China
| | - Gege Xiong
- Stomatological Hospital, Southern Medical University, Guangzhou, 510280, People’s Republic of China
| | - Chao Zhang
- Stomatological Hospital, Southern Medical University, Guangzhou, 510280, People’s Republic of China
| |
Collapse
|
18
|
Bonelli J, Velasco-de Andrés M, Isidro N, Bayó C, Chumillas S, Carrillo-Serradell L, Casadó-Llombart S, Mok C, Benítez-Ribas D, Lozano F, Rocas J, Marchán V. Novel Tumor-Targeted Self-Nanostructured and Compartmentalized Water-in-Oil-in-Water Polyurethane-Polyurea Nanocapsules for Cancer Theragnosis. Pharmaceutics 2022; 15:pharmaceutics15010058. [PMID: 36678687 PMCID: PMC9862617 DOI: 10.3390/pharmaceutics15010058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 11/26/2022] [Accepted: 12/20/2022] [Indexed: 12/28/2022] Open
Abstract
Encapsulation of water-soluble bioactive compounds for enabling specific accumulation in tumor locations, while avoiding premature clearance and/or degradation in the bloodstream, is one of the main hallmarks in nanomedicine, especially that of NIR fluorescent probes for cancer theragnosis. The herein reported technology furnishes water-dispersible double-walled polyurethane-polyurea hybrid nanocapsules (NCs) loaded with indocyanine green (ICG-NCs), using a versatile and highly efficient one-pot and industrially scalable synthetic process based on the use of two different prepolymers to set up the NCs walls. Flow cytometry and confocal microscopy confirmed that both ICG-loaded NCs internalized in monocyte-derived dendritic cells (moDCs). The in vivo analysis of xenograft A375 mouse melanoma model revealed that amphoteric functionalization of NCs' surface promotes the selective accumulation of ICG-NCs in tumor tissues, making them promising agents for a less-invasive theragnosis of cancer.
Collapse
Affiliation(s)
- Joaquín Bonelli
- Departament de Química Inorgànica i Orgànica, Secció de Química Orgànica, Institut de Biomedicina de la Universitat de Barcelona (IBUB), Universitat de Barcelona (UB), Martí i Franquès 1-11, E-08028 Barcelona, Spain
- Nanobiotechnological Polymers Division Ecopol Tech, S.L., El Foix Business Park, Indústria 7, L'Arboç del Penedès, E-43720 Tarragona, Spain
| | - María Velasco-de Andrés
- Immunoreceptors del Sistema Innat i Adaptatiu, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Rosselló 149-151, E-08036 Barcelona, Spain
| | - Neus Isidro
- Nanobiotechnological Polymers Division Ecopol Tech, S.L., El Foix Business Park, Indústria 7, L'Arboç del Penedès, E-43720 Tarragona, Spain
| | - Cristina Bayó
- Servei d'Immunologia, Centre de Diagnòstic Biomèdic, Hospital Clínic de Barcelona, Villarroel 170, E-08036 Barcelona, Spain
| | - Sergi Chumillas
- Departament de Química Inorgànica i Orgànica, Secció de Química Orgànica, Institut de Biomedicina de la Universitat de Barcelona (IBUB), Universitat de Barcelona (UB), Martí i Franquès 1-11, E-08028 Barcelona, Spain
| | - Laura Carrillo-Serradell
- Immunoreceptors del Sistema Innat i Adaptatiu, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Rosselló 149-151, E-08036 Barcelona, Spain
| | - Sergi Casadó-Llombart
- Immunoreceptors del Sistema Innat i Adaptatiu, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Rosselló 149-151, E-08036 Barcelona, Spain
| | - Cheryl Mok
- Servei d'Immunologia, Centre de Diagnòstic Biomèdic, Hospital Clínic de Barcelona, Villarroel 170, E-08036 Barcelona, Spain
| | - Daniel Benítez-Ribas
- Servei d'Immunologia, Centre de Diagnòstic Biomèdic, Hospital Clínic de Barcelona, Villarroel 170, E-08036 Barcelona, Spain
| | - Francisco Lozano
- Immunoreceptors del Sistema Innat i Adaptatiu, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Rosselló 149-151, E-08036 Barcelona, Spain
- Servei d'Immunologia, Centre de Diagnòstic Biomèdic, Hospital Clínic de Barcelona, Villarroel 170, E-08036 Barcelona, Spain
- Departament de Biomedicina, Universitat de Barcelona (UB), Villarroel 170, E-08036 Barcelona, Spain
| | - Josep Rocas
- Nanobiotechnological Polymers Division Ecopol Tech, S.L., El Foix Business Park, Indústria 7, L'Arboç del Penedès, E-43720 Tarragona, Spain
| | - Vicente Marchán
- Departament de Química Inorgànica i Orgànica, Secció de Química Orgànica, Institut de Biomedicina de la Universitat de Barcelona (IBUB), Universitat de Barcelona (UB), Martí i Franquès 1-11, E-08028 Barcelona, Spain
| |
Collapse
|
19
|
Hodge JG, Zamierowski DS, Robinson JL, Mellott AJ. Evaluating polymeric biomaterials to improve next generation wound dressing design. Biomater Res 2022; 26:50. [PMID: 36183134 PMCID: PMC9526981 DOI: 10.1186/s40824-022-00291-5] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Accepted: 08/28/2022] [Indexed: 11/24/2022] Open
Abstract
Wound healing is a dynamic series of interconnected events with the ultimate goal of promoting neotissue formation and restoration of anatomical function. Yet, the complexity of wound healing can often result in development of complex, chronic wounds, which currently results in a significant strain and burden to our healthcare system. The advancement of new and effective wound care therapies remains a critical issue, with the current therapeutic modalities often remaining inadequate. Notably, the field of tissue engineering has grown significantly in the last several years, in part, due to the diverse properties and applications of polymeric biomaterials. The interdisciplinary cohesion of the chemical, biological, physical, and material sciences is pertinent to advancing our current understanding of biomaterials and generating new wound care modalities. However, there is still room for closing the gap between the clinical and material science realms in order to more effectively develop novel wound care therapies that aid in the treatment of complex wounds. Thus, in this review, we discuss key material science principles in the context of polymeric biomaterials, provide a clinical breadth to discuss how these properties affect wound dressing design, and the role of polymeric biomaterials in the innovation and design of the next generation of wound dressings.
Collapse
Affiliation(s)
- Jacob G Hodge
- Bioengineering Graduate Program, University of Kansas, Lawrence, KS, USA.,Department of Plastic Surgery, University of Kansas Medical Center, Kansas City, KS, USA
| | - David S Zamierowski
- Department of Plastic Surgery, University of Kansas Medical Center, Kansas City, KS, USA
| | - Jennifer L Robinson
- Department of Chemical and Petroleum Engineering, University of Kansas, Mail Stop: 3051, 3901 Rainbow Blvd, Lawrence, KS, 66160, USA
| | - Adam J Mellott
- Department of Plastic Surgery, University of Kansas Medical Center, Kansas City, KS, USA.
| |
Collapse
|
20
|
Kumar S, Bhowmik S. Potential use of natural fiber-reinforced polymer biocomposites in knee prostheses: a review on fair inclusion in amputees. IRANIAN POLYMER JOURNAL 2022. [DOI: 10.1007/s13726-022-01077-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
21
|
Ju DB, Lee JC, Hwang SK, Cho CS, Kim HJ. Progress of Polysaccharide-Contained Polyurethanes for Biomedical Applications. Tissue Eng Regen Med 2022; 19:891-912. [PMID: 35819712 PMCID: PMC9478012 DOI: 10.1007/s13770-022-00464-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2022] [Revised: 04/10/2022] [Accepted: 05/01/2022] [Indexed: 11/26/2022] Open
Abstract
Polyurethane (PU) has been widely examined and used for biomedical applications, such as catheters, blood oxygenators, stents, cardiac valves, drug delivery carriers, dialysis devices, wound dressings, adhesives, pacemaker, tissue engineering, and coatings for breast implants due to its mechanical flexibility, high tear strength, biocompatibility, and tailorable foams although bio-acceptability, biodegradability and controlled drug delivery to achieve the desired properties should be considered. Especially, during the last decade, the development of bio-based PUs has raised public awareness because of the concern with global plastic waste for creating more environmentally friended materials. Therefore, it is desirable to discuss polysaccharide (PS)-contained PU for the wound dressing and bone tissue engineering among bio-based PUs because PS has several advantages, such as biocompatibility, reproducibility from the natural resources, degradability, ease of incorporation of bioactive agents, ease of availability and cost-effectiveness, and structural feature of chemical modification to meet the desired needs to overcome the disadvantages of PU itself by containing the PS into the PU.
Collapse
Affiliation(s)
- Do-Bin Ju
- Department of Agricultural Biotechnology, Seoul National University, Seoul, 08824, Korea
| | - Jeong-Cheol Lee
- Department of Agricultural Biotechnology, Seoul National University, Seoul, 08824, Korea
| | - Soo-Kyung Hwang
- Research Institute of Agriculture and Life Sciences, Seoul National University, Seoul, 08824, Korea
- Program in Environmental Materials Science, Department of Agriculture, Forestry and Bioresources, Seoul National University, Seoul, 08824, Korea
| | - Chong-Su Cho
- Department of Agricultural Biotechnology, Seoul National University, Seoul, 08824, Korea.
- Research Institute of Agriculture and Life Sciences, Seoul National University, Seoul, 08824, Korea.
| | - Hyun-Joong Kim
- Research Institute of Agriculture and Life Sciences, Seoul National University, Seoul, 08824, Korea.
- Program in Environmental Materials Science, Department of Agriculture, Forestry and Bioresources, Seoul National University, Seoul, 08824, Korea.
| |
Collapse
|
22
|
Tigmeanu CV, Ardelean LC, Rusu LC, Negrutiu ML. Additive Manufactured Polymers in Dentistry, Current State-of-the-Art and Future Perspectives-A Review. Polymers (Basel) 2022; 14:3658. [PMID: 36080732 PMCID: PMC9460687 DOI: 10.3390/polym14173658] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 08/21/2022] [Accepted: 09/01/2022] [Indexed: 11/16/2022] Open
Abstract
3D-printing application in dentistry not only enables the manufacture of patient-specific devices and tissue constructs, but also allows mass customization, as well as digital workflow, with predictable lower cost and rapid turnaround times. 4D printing also shows a good impact in dentistry, as it can produce dynamic and adaptable materials, which have proven effective in the oral environment, under its continuously changing thermal and humidity conditions. It is expected to further boost the research into producing a whole tooth, capable to harmoniously integrate with the surrounding periodontium, which represents the ultimate goal of tissue engineering in dentistry. Because of their high versatility associated with the wide variety of available materials, additive manufacturing in dentistry predominantly targets the production of polymeric constructs. The aim of this narrative review is to catch a glimpse of the current state-of-the-art of additive manufacturing in dentistry, and the future perspectives of this modern technology, focusing on the specific polymeric materials.
Collapse
Affiliation(s)
- Codruta Victoria Tigmeanu
- Department of Technology of Materials and Devices in Dental Medicine, Faculty of Dental Medicine, Multidisciplinary Center for Research, Evaluation, Diagnosis and Therapies in Oral Medicine, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania
| | - Lavinia Cosmina Ardelean
- Department of Technology of Materials and Devices in Dental Medicine, Faculty of Dental Medicine, Multidisciplinary Center for Research, Evaluation, Diagnosis and Therapies in Oral Medicine, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania
| | - Laura-Cristina Rusu
- Department of Oral Pathology, Faculty of Dental Medicine, Multidisciplinary Center for Research, Evaluation, Diagnosis and Therapies in Oral Medicine, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania
| | - Meda-Lavinia Negrutiu
- Department of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, Research Center in Dental Medicine Using Conventional and Alternative Technologies, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania
| |
Collapse
|
23
|
Synthesis of diethylene glycol-based aliphatic polyester polyol and effect of glycerin crosslinker on its properties. JOURNAL OF POLYMER RESEARCH 2022. [DOI: 10.1007/s10965-022-03199-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
|
24
|
Xu C, Hong Y. Rational design of biodegradable thermoplastic polyurethanes for tissue repair. Bioact Mater 2022; 15:250-271. [PMID: 35386346 PMCID: PMC8940769 DOI: 10.1016/j.bioactmat.2021.11.029] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 11/09/2021] [Accepted: 11/24/2021] [Indexed: 12/25/2022] Open
Abstract
As a type of elastomeric polymers, non-degradable polyurethanes (PUs) have a long history of being used in clinics, whereas biodegradable PUs have been developed in recent decades, primarily for tissue repair and regeneration. Biodegradable thermoplastic (linear) PUs are soft and elastic polymeric biomaterials with high mechanical strength, which mimics the mechanical properties of soft and elastic tissues. Therefore, biodegradable thermoplastic polyurethanes are promising scaffolding materials for soft and elastic tissue repair and regeneration. Generally, PUs are synthesized by linking three types of changeable blocks: diisocyanates, diols, and chain extenders. Alternating the combination of these three blocks can finely tailor the physio-chemical properties and generate new functional PUs. These PUs have excellent processing flexibilities and can be fabricated into three-dimensional (3D) constructs using conventional and/or advanced technologies, which is a great advantage compared with cross-linked thermoset elastomers. Additionally, they can be combined with biomolecules to incorporate desired bioactivities to broaden their biomedical applications. In this review, we comprehensively summarized the synthesis, structures, and properties of biodegradable thermoplastic PUs, and introduced their multiple applications in tissue repair and regeneration. A whole picture of their design and applications along with discussions and perspectives of future directions would provide theoretical and technical supports to inspire new PU development and novel applications.
Collapse
Affiliation(s)
- Cancan Xu
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Yi Hong
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| |
Collapse
|
25
|
Jiang L, Chen M, Huang Y, Peng J, Zhao J, Chan F, Yu X. Effects of different treatment processes in four municipal wastewater treatment plants on the transport and fate of microplastics. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 831:154946. [PMID: 35364157 DOI: 10.1016/j.scitotenv.2022.154946] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 03/27/2022] [Accepted: 03/27/2022] [Indexed: 06/14/2023]
Abstract
The behavior of microplastics in wastewater treatment plants has been investigated, but specific effects of treatment process on microplastics' fate are still unclear due to varied analysis methods and regional differences. In this study, four wastewater treatment plants in Ningbo of southeastern China with different treatment processes were selected to investigate transport and fate of microplastics. Based on number of microplastic particles, fibers and fragments were the main microplastics types in wastewater, while synthetic cellulose represented the largest fraction. The dominance of fibers (76.7%-90.0%) and small particle sizes (<2.0 mm, 62.5%-81.5%) in effluents suggested that they escaped easily from the wastewater treatment plants. The abundance of microplastics particles decreased from 78.0 ± 2.9 items/L in influent to 6.0 ± 2.8 items/L in effluent for anaerobic-anoxic-oxic process, 100.0 ± 3.1 items/L to 4.3 ± 3.4 items/L for sequencing batch reactor activated sludge process, 105.0 ± 5.3 items/L to 3.5 ± 2.6 items/L for cyclic activated sludge technology, 65.0 ± 4.3 items/L to 3.0 ± 1.6 items/L for oxidation ditch process. The microplastics removal capacity of primary and secondary treatment processes for four wastewater treatment plants ranged from 83.7% to 96.3%. Application of different tertiary treatment processes (coagulation/flocculation, membrane related technology and disinfection) enhanced microplastics removal to achieve overall removal rate of 92.3%-96.7%. The removed microplastics from the wastewater treatment plants were mainly transferred to sludge (226.1 ± 95.7-896.0 ± 144.0 items/g dry weight). The biological treatment unit played an important role in microplastics removal with rates varying between 86.9%-95.2%, while tertiary treatment reduced daily microplastics emission 1.4 × 108-2.3 × 108 items/day. This study suggests that proper selection of wastewater treatment unit could significantly reduce the emission number of microplastics, which supports an efficient control strategy of microplastics in wastewater treatment plants.
Collapse
Affiliation(s)
- Li Jiang
- School of Civil and Environmental Engineering, Ningbo University, Ningbo 315211, PR China
| | - Minglong Chen
- School of Civil and Environmental Engineering, Ningbo University, Ningbo 315211, PR China
| | - Ying Huang
- School of Civil and Environmental Engineering, Ningbo University, Ningbo 315211, PR China
| | - Jinping Peng
- Faculty of Chemical Engineering and Light Industry, Guangdong University of Technology, Guangzhou 510006, PR China
| | - Jianliang Zhao
- School of Environment, South China Normal University, Guangzhou 510006, PR China
| | - Faith Chan
- School of Geographical Sciences, University of Nottingham Ningbo China, Ningbo 315100, PR China
| | - Xubiao Yu
- School of Civil and Environmental Engineering, Ningbo University, Ningbo 315211, PR China.
| |
Collapse
|
26
|
Lee AL, Hsieh HY, Chen YY, Tsai LH, Wey SL, Chen DS, Chen YJ, Young TH. Novel Application of Photo-Crosslinked Urocanic-Acid-Modified Chitosan in Corneal Wounds. ACS Biomater Sci Eng 2022; 8:2016-2027. [PMID: 35412808 DOI: 10.1021/acsbiomaterials.2c00050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In the last few years, the use of tissue adhesives in corneal perforation has gained immense popularity in clinical practices. The present study aimed to devise a new application of urocanic-acid-modified chitosan (CS) with methylene blue (MB) as a photosensitizer for the development of a photo-crosslinked tissue adhesive. In particular, the curing time was controlled with the aid of a 650 nm red diode. Under the same irradiation condition, the mechanical properties were tuned using the photosensitizer at different concentrations. In vitro tests revealed that the gel was ductile and biocompatible. The application of the gel to a perforated cornea model stopped the leakage of aqueous humor, immediately after the gel was photo-crosslinked. The blue appearance of the gel provided high precision when applied to corneal wounds. Importantly, the crosslinked gel became transparent within 24 h, owing to the dissipation of MB from tears, and the gel spontaneously sloughed off without artificial removal. Altogether, the study reported the development of a novel photo-crosslinkable urocanic-acid-modified CS gel that exhibited significant potential to be utilized in the healing of corneal perforation.
Collapse
Affiliation(s)
- An-Li Lee
- Department of Biomedical Engineering, National Taiwan University, Taipei 100, Taiwan.,Division of Plastic Surgery, Department of Surgery, MacKay Memorial Hospital, Taipei 104, Taiwan
| | - Hao-Ying Hsieh
- Department of Biomedical Engineering, National Taiwan University, Taipei 100, Taiwan.,Department of Dentistry, National Taiwan University Hospital, Taipei 100, Taiwan
| | - Yun-Yu Chen
- Department of Biomedical Engineering, National Taiwan University, Taipei 100, Taiwan
| | - Li-Hui Tsai
- Department of Biomedical Engineering, National Taiwan University, Taipei 100, Taiwan
| | - Shiuan-Li Wey
- Department of Pathology, Hsinchu MacKay Memorial Hospital, Hsinchu 30071, Taiwan
| | - Dai-Shi Chen
- Translational Cell Biology and Neurooncology Laboratory, Universitätsklinikum Erlangen (UKER), Friedrich-Alexander University of Erlangen-Nürnberg (FAU), Erlangen 91054, Germany
| | - Yi-Jane Chen
- Department of Dentistry, National Taiwan University Hospital, Taipei 100, Taiwan
| | - Tai-Horng Young
- Department of Biomedical Engineering, National Taiwan University, Taipei 100, Taiwan
| |
Collapse
|
27
|
Khadem E, Kharaziha M, Bakhsheshi-Rad HR, Das O, Berto F. Cutting-Edge Progress in Stimuli-Responsive Bioadhesives: From Synthesis to Clinical Applications. Polymers (Basel) 2022; 14:1709. [PMID: 35566878 PMCID: PMC9104595 DOI: 10.3390/polym14091709] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 03/31/2022] [Accepted: 04/08/2022] [Indexed: 02/04/2023] Open
Abstract
With the advent of "intelligent" materials, the design of smart bioadhesives responding to chemical, physical, or biological stimuli has been widely developed in biomedical applications to minimize the risk of wounds reopening, chronic pain, and inflammation. Intelligent bioadhesives are free-flowing liquid solutions passing through a phase shift in the physiological environment due to stimuli such as light, temperature, pH, and electric field. They possess great merits, such as ease to access and the ability to sustained release as well as the spatial transfer of a biomolecule with reduced side effects. Tissue engineering, wound healing, drug delivery, regenerative biomedicine, cancer therapy, and other fields have benefited from smart bioadhesives. Recently, many disciplinary attempts have been performed to promote the functionality of smart bioadhesives and discover innovative compositions. However, according to our knowledge, the development of multifunctional bioadhesives for various biomedical applications has not been adequately explored. This review aims to summarize the most recent cutting-edge strategies (years 2015-2021) developed for stimuli-sensitive bioadhesives responding to external stimuli. We first focus on five primary categories of stimuli-responsive bioadhesive systems (pH, thermal, light, electric field, and biomolecules), their properties, and limitations. Following the introduction of principal criteria for smart bioadhesives, their performances are discussed, and certain smart polymeric materials employed in their creation in 2015 are studied. Finally, advantages, disadvantages, and future directions regarding smart bioadhesives for biomedical applications are surveyed.
Collapse
Affiliation(s)
- Elham Khadem
- Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran;
| | - Mahshid Kharaziha
- Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran;
| | - Hamid Reza Bakhsheshi-Rad
- Advanced Materials Research Center, Department of Materials Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran;
| | - Oisik Das
- Structural and Fire Engineering Division, Department of Civil, Environmental and Natural Resources Engineering, Luleå University of Technology, 97187 Luleå, Sweden;
| | - Filippo Berto
- Department of Mechanical and Industrial Engineering, Norwegian University of Science and Technology, 7491 Trondheim, Norway
| |
Collapse
|
28
|
Abstract
Graphene material has a variety of excellent properties and applications in energy storage, biomaterials, photoelectric devices, and other fields. With the progress of nanotechnology, graphene nanomaterials have shown their advantages in the field of new nano-corrosion coatings with their high barrier structure. In addition, polyurethane is also widely used in the field of anti-corrosion coatings due to its excellent chemical resistance, mechanical properties, and weathering resistance. The preparation of composite coatings by combining graphene nanomaterials with traditional polyurethane (PU) coatings has opened up a new way for the research and development of new anticorrotic coatings. In this paper, graphene polyurethane composite coating was first used as the research object, and the mechanism of graphene material in the new composite coating was analyzed. Then, graphene oxide (GO), a commonly used precursor material, was used as an entry point for a detailed study of the properties of GO materials and the advantages and disadvantages of its application in composites, and two types of modifications, covalent and non-covalent, were analyzed. In addition, the preparation methods and processes of graphene polyurethane composite coatings were summarized. Finally, the future research directions and research focus of GO were prospected.
Collapse
|
29
|
Moreno-Lanceta A, Medrano-Bosch M, Edelman ER, Melgar-Lesmes P. Polymeric Nanoparticles for Targeted Drug and Gene Delivery Systems. NANOTECHNOLOGY IN THE LIFE SCIENCES 2022:561-608. [DOI: 10.1007/978-3-031-12658-1_19] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
|
30
|
Shih CY, Huang JZ, Chen MH, Hsu CC, Wu CI, Cheng IC, Chen JZ. The Influence of Helium Dielectric Barrier Discharge Jet (DBDjet) Plasma Treatment on Bathocuproine (BCP) in p-i-n-Structure Perovskite Solar Cells. Polymers (Basel) 2021; 13:4020. [PMID: 34833316 PMCID: PMC8622915 DOI: 10.3390/polym13224020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 11/15/2021] [Accepted: 11/17/2021] [Indexed: 01/06/2023] Open
Abstract
A bathocuproine (BCP) layer is typically used as the hole-blocking layer in p-i-n-structure perovskite solar cells (PSCs) between PC61BM and Ag electrodes. Before evaporating the Ag, we used a low-temperature (<40 °C) atmospheric-pressure dielectric barrier discharge jet (DBDjet) to treat the BCP with different scan rates. The main purpose of this was to change the contact resistance between the BCP layer and the Ag electrodes through surface modification using a DBDjet. The best power conversion efficiency (PCE) of 13.11% was achieved at a DBDjet scan rate of 2 cm/s. The He DBDjet treatment introduced nitrogen to form C-N bonds and create pits on the BCP layer. This deteriorated the interface between the BCP and the follow-up deposited-Ag top electrode. Compared to the device without the plasma treatment on the BCP layer, the He DBDjet treatment on the BCP layer reduced photocurrent hysteresis but deteriorated the fill factor and the efficiency of the PSCs.
Collapse
Affiliation(s)
- Chung-Yueh Shih
- Graduate Institute of Applied Mechanics, National Taiwan University, Taipei City 10617, Taiwan;
- Advanced Research Center for Green Materials Science and Technology, National Taiwan University, Taipei City 10617, Taiwan
| | - Jian-Zhi Huang
- Graduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei City 10617, Taiwan; (J.-Z.H.); (C.-I.W.); (I.-C.C.)
| | - Mei-Hsin Chen
- Department of Electro-Optical Engineering, National Taipei University of Technology, Taipei City 10608, Taiwan;
| | - Cheng-Che Hsu
- Department of Chemical Engineering, National Taiwan University, Taipei City 10617, Taiwan;
| | - Chih-I Wu
- Graduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei City 10617, Taiwan; (J.-Z.H.); (C.-I.W.); (I.-C.C.)
| | - I-Chun Cheng
- Graduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei City 10617, Taiwan; (J.-Z.H.); (C.-I.W.); (I.-C.C.)
- Department of Electrical Engineering, National Taiwan University, Taipei City 10617, Taiwan
- Innovative Photonics Advanced Research Center (i-PARC), National Taiwan University, Taipei City 10617, Taiwan
| | - Jian-Zhang Chen
- Graduate Institute of Applied Mechanics, National Taiwan University, Taipei City 10617, Taiwan;
- Advanced Research Center for Green Materials Science and Technology, National Taiwan University, Taipei City 10617, Taiwan
- Innovative Photonics Advanced Research Center (i-PARC), National Taiwan University, Taipei City 10617, Taiwan
| |
Collapse
|
31
|
Nakan U, Bieerkehazhi S, Tolkyn B, Mun GA, Assanov M, Nursultanov ME, Rakhmetullayeva RK, Toshtay K, Negim ES, Ydyrys A. Synthesis, Characterization and Antibacterial Application of Copolymers Based on N, N-Dimethyl Acrylamide and Acrylic Acid. MATERIALS 2021; 14:ma14206191. [PMID: 34683781 PMCID: PMC8540520 DOI: 10.3390/ma14206191] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 10/08/2021] [Accepted: 10/09/2021] [Indexed: 11/16/2022]
Abstract
Hydrogel copolymers based on N,N-dimethyl acrylamide (DMA) and acrylic acid (AAc) were synthesized using a solution polymerization technique with different monomer ratios and ammonium persulfate as an initiator. This paper investigates the thermal stability, physical and chemical properties of the hydrogel copolymer. Testing includes Fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), scanning electron microscopy (SEM) and elemental analysis (CHNS). The copolymer composition was determined by elemental analysis, and the reactivity ratios of monomers were calculated through linearization methods such as Fineman–Ross (FR), inverted Fineman–Ross (IFR), Kelen–Tudos (KT) and Mayo–Lewis (ML). Good agreement was observed between the results of all four methods. The ratio of r1 and r2 were 0.38 (r1) and 1.45 (r2) (FR), 0.38 (r1) and 1.46 (r2) (IFR), 0.38 (r1) and 1.43 (r2) (KT), and 0.38 (r1) and 1.45 (r2) (ML). Hydrogel copolymers exhibited good thermal stability, and SEM showed three-dimensional porous structures. Antibiotic-free and antibiotic-loaded hydrogels demonstrated antimicrobial properties against both Gram-positive and Gram-negative bacteria. As the ratio of DMA in hydrogel copolymer increased, the activity of copolymer against bacteria enhanced. The results indicated that these hydrogels have the potential to be used as antibacterial materials.
Collapse
Affiliation(s)
- Ulantay Nakan
- Institute of Geology and Oil & Gas Business, Satbayev University, Almaty 050013, Kazakhstan;
- Correspondence: ; Tel.: +7-701-165-89-36
| | - Shayahati Bieerkehazhi
- Ross Tilley Burn Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, ON M5S 1A1, Canada;
| | - Balgyn Tolkyn
- A.B. Bekturov Institute of Chemical Sciences, Street Ualihanov106, Almaty 050010, Kazakhstan;
| | - Grigoriy A. Mun
- Al-Farabi Kazakh National University, Almaty 050012, Kazakhstan; (G.A.M.); (M.A.); (R.K.R.); (K.T.)
| | - Mukhit Assanov
- Al-Farabi Kazakh National University, Almaty 050012, Kazakhstan; (G.A.M.); (M.A.); (R.K.R.); (K.T.)
| | - Merey E. Nursultanov
- Institute of Geology and Oil & Gas Business, Satbayev University, Almaty 050013, Kazakhstan;
| | | | - Kainaubek Toshtay
- Al-Farabi Kazakh National University, Almaty 050012, Kazakhstan; (G.A.M.); (M.A.); (R.K.R.); (K.T.)
| | - El-Sayed Negim
- Laboratory of Advanced Materials and Technology, Kazakh-British Technical University, 59 Tole bi St., Almaty 050000, Kazakhstan;
| | - Alibek Ydyrys
- Biomedical Research Centre, Al-Farabi Kazakh National University, al-Farabi 71, Almaty 050040, Kazakhstan;
| |
Collapse
|
32
|
Assessment of Electrospun Pellethane-Based Scaffolds for Vascular Tissue Engineering. MATERIALS 2021; 14:ma14133678. [PMID: 34279249 PMCID: PMC8269885 DOI: 10.3390/ma14133678] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 06/12/2021] [Accepted: 06/28/2021] [Indexed: 11/16/2022]
Abstract
We examined the physicochemical properties and the biocompatibility and hemocompatibility of electrospun 3D matrices produced using polyurethane Pellethane 2363-80A (Pel-80A) blends Pel-80A with gelatin or/and bivalirudin. Two layers of vascular grafts of 1.8 mm in diameter were manufactured and studied for hemocompatibility ex vivo and functioning in the infrarenal position of Wistar rat abdominal aorta in vivo (n = 18). Expanded polytetrafluoroethylene (ePTFE) vascular grafts of similar diameter were implanted as a control (n = 18). Scaffolds produced from Pel-80A with Gel showed high stiffness with a long proportional limit and limited influence of wetting on mechanical characteristics. The electrospun matrices with gelatin have moderate capacity to support cell adhesion and proliferation (~30–47%), whereas vascular grafts with bivalirudin in the inner layer have good hemocompatibility ex vivo. The introduction of bivalirudin into grafts inhibited platelet adhesion and does not lead to a change hemolysis and D-dimers concentration. Study in vivo indicates the advantages of Pel-80A grafts over ePTFE in terms of graft occlusion, calcification level, and blood velocity after 6 months of implantation. The thickness of neointima in Pel-80A–based grafts stabilizes after three months (41.84 ± 20.21 µm) and does not increase until six months, demonstrating potential for long-term functioning without stenosis and as a suitable candidate for subsequent preclinical studies in large animals.
Collapse
|
33
|
Clinical Outcomes of Self-Made Polyurethane-Covered Stent Implantation for the Treatment of Coronary Artery Perforations. J Interv Cardiol 2021; 2021:6661763. [PMID: 34104120 PMCID: PMC8143889 DOI: 10.1155/2021/6661763] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Accepted: 04/29/2021] [Indexed: 11/17/2022] Open
Abstract
Objectives The present study aimed to investigate the short- and long-term clinical outcomes of self-made polyurethane-covered stents (PU-CS) in patients for the management of coronary artery perforation (CAP) during percutaneous coronary intervention (PCI). Background Coronary artery perforation is reckoned as a serious complication in PCI and associated with considerable morbidity and mortality. Covered stents have been used for treating the life-threatening CAP during PCI. But in some catheterization laboratories, no commercial CS is immediately available when there is an urgent need for CS to rescue the coronary rupture site. Methods We retrospectively identified 24 patients who underwent 31 self-made PU-CS implantations due to CAP in Zhongshan Hospital, Fudan University, from June 2015 to January 2020. Results The total procedural success rate of CS to seal the perforation was 79.2%. Nine patients (37.5%) developed cardiac tamponade, of which 8 patients (33.3%) underwent pericardiocentesis and 4 patients (16.7%) underwent cardiac surgeries. Except for 4 cardiac death cases (16.7%), none of myocardial infarction (MI), target lesion revascularization (TLR), and stent thrombosis (ST) was reported during hospital stay. Data from 22 patients (91.7%) were available at 610.4 ± 420.9 days of follow-up. Major adverse cardiac events (MACE) occurred in 6 patients (27.3%), including 5 cases of cardiac death and one TLR case. Conclusions Self-made PU-CS demonstrates high rates of successful delivery and sealing of severe CAP during PCI. Although the in-hospital mortality remains high after PU-CS implantation, the long-term follow-up shows favorable clinical outcomes, indicating the feasibility of PU-CS in treating CAP.
Collapse
|
34
|
Olmos D, González-Benito J. Polymeric Materials with Antibacterial Activity: A Review. Polymers (Basel) 2021; 13:613. [PMID: 33670638 PMCID: PMC7922637 DOI: 10.3390/polym13040613] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2021] [Revised: 02/02/2021] [Accepted: 02/10/2021] [Indexed: 12/21/2022] Open
Abstract
Infections caused by bacteria are one of the main causes of mortality in hospitals all over the world. Bacteria can grow on many different surfaces and when this occurs, and bacteria colonize a surface, biofilms are formed. In this context, one of the main concerns is biofilm formation on medical devices such as urinary catheters, cardiac valves, pacemakers or prothesis. The development of bacteria also occurs on materials used for food packaging, wearable electronics or the textile industry. In all these applications polymeric materials are usually present. Research and development of polymer-based antibacterial materials is crucial to avoid the proliferation of bacteria. In this paper, we present a review about polymeric materials with antibacterial materials. The main strategies to produce materials with antibacterial properties are presented, for instance, the incorporation of inorganic particles, micro or nanostructuration of the surfaces and antifouling strategies are considered. The antibacterial mechanism exerted in each case is discussed. Methods of materials preparation are examined, presenting the main advantages or disadvantages of each one based on their potential uses. Finally, a review of the main characterization techniques and methods used to study polymer based antibacterial materials is carried out, including the use of single force cell spectroscopy, contact angle measurements and surface roughness to evaluate the role of the physicochemical properties and the micro or nanostructure in antibacterial behavior of the materials.
Collapse
Affiliation(s)
- Dania Olmos
- Department of Materials Science and Engineering and Chemical Engineering, Instituto de Química y Materiales Álvaro Alonso Barba (IQMAA), Universidad Carlos III de Madrid, Leganés, 28911 Madrid, Spain
| | - Javier González-Benito
- Department of Materials Science and Engineering and Chemical Engineering, Instituto de Química y Materiales Álvaro Alonso Barba (IQMAA), Universidad Carlos III de Madrid, Leganés, 28911 Madrid, Spain
| |
Collapse
|
35
|
Khan AS, Ur Rehman S, AlMaimouni YK, Ahmad S, Khan M, Ashiq M. Bibliometric Analysis of Literature Published on Antibacterial Dental Adhesive from 1996-2020. Polymers (Basel) 2020; 12:E2848. [PMID: 33260410 PMCID: PMC7761276 DOI: 10.3390/polym12122848] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2020] [Revised: 11/21/2020] [Accepted: 11/26/2020] [Indexed: 12/28/2022] Open
Abstract
This study aimed to investigate the current state of research on antibacterial dental adhesives. The interest in this field can be drawn from an increasing number of scholarly works in this area. However, there is still a lack of quantitative measurement of this topic. The main aim of this study was to consolidate the research published on the antibacterial adhesive from 1996 to 2020 in Web of Science indexed journals. The bibliometric method, a quantitative study of investigating publishing trends and patterns, was used for this study. The result has shown that a gradual increase in research was found, whereby a substantial increase was observed from 2013. A total of 248 documents were published in 84 journals with total citations of 5107. The highly cited articles were published mainly in Q1 category journals. Most of the published articles were from the USA, China, and other developed countries; however, some developing countries contributed as well. The authorship pattern showed an interdisciplinary and collaborative approach among researchers. The thematic evaluation of keywords along with a three-factor analysis showed that 'antibacterial adhesives' and 'quaternary ammonium' have been used commonly. This bibliometric analysis can provide direction not only to researchers but also to funding organizations and policymakers.
Collapse
Affiliation(s)
- Abdul Samad Khan
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia;
| | - Shafiq Ur Rehman
- Deanship of Library Affairs, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia;
| | - Yara Khalid AlMaimouni
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia;
| | - Shakil Ahmad
- Central Library, Prince Sultan University, Riyadh 11586, Saudi Arabia;
| | - Maria Khan
- Department of Oral Biology, University of Health Sciences, Lahore 54000, Pakistan;
| | - Murtaza Ashiq
- Islamabad Model College for Boys, H-9, Islamabad 44000, Pakistan;
| |
Collapse
|
36
|
Sun JT, Li JW, Tsou CH, Pang JC, Chung RJ, Chiu CW. Polyurethane/Nanosilver-Doped Halloysite Nanocomposites: Thermal, Mechanical Properties, and Antibacterial Properties. Polymers (Basel) 2020; 12:polym12112729. [PMID: 33213077 PMCID: PMC7698514 DOI: 10.3390/polym12112729] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2020] [Revised: 11/13/2020] [Accepted: 11/15/2020] [Indexed: 01/09/2023] Open
Abstract
In this study, the researchers successfully embellished the surface of halloysite (Ag/HNTs) with silver using halloysite, silver nitrate (AgNO3), and polyvinylpyrrolidone (PVP). The researchers then prepared polyurethane that contained pyridine ring by using 4,4′-diphenylmethane diisocyanate (MDI) and polytetramethylene glycol (PTMG) as the hard chain segment and the soft chain segment of polyurethane (PU), as well as 2,6-pyridinedimethanol (2,6-PDM) as the chain extension agent. This was followed by the preparation of Ag/HNTs/PUs nanocomposite thin films, achieved by mixing Ag/HNTs with different ratios into polyurethane that contains pyridine ring. First, the Ag/HNTs powders were analyzed using energy-dispersive X-ray spectroscopy, X-ray diffraction, and transmission electron microscopy. Subsequently, Fourier-transform infrared spectroscopy was used to examine the dispersibility of Ag/HNTs in PU, whereas the thermal stability and the viscoelasticity of Ag/HNTs/PU were examined using thermal gravimetric analysis, differential scanning calorimetry, and dynamic mechanical analysis. When the mechanical properties of Ag/HNTs/PU were tested using a universal strength tester, the results indicated a maximum increase of 109.5% in tensile strength. The researchers then examined the surface roughness and the hydrophobic ability of the Ag/HNTs/PU thin films by using atomic force microscopy and water contact angle. Lastly, antibacterial testing on Escherichia coli revealed that when the additive of Ag/HNTs reached 2.0 wt%, 99.3% of the E. coli were eliminated. These results indicated that the addition of Ag/HNTs into PU could enhance the thermal stability, mechanical properties, and antibacterial properties of PU, implying the potential of Ag/HNTs-02 as biomedicine material.
Collapse
Affiliation(s)
- Jui-Ting Sun
- Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan; (J.-T.S.); (J.-W.L.)
| | - Jia-Wun Li
- Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan; (J.-T.S.); (J.-W.L.)
| | - Chi-Hui Tsou
- Material Corrosion and Protection Key Laboratory of Sichuan Province, College of Materials Science and Engineering, Sichuan University of Science and Engineering, Zigong 643000, China;
| | - Jen-Chieh Pang
- Department of Biotechnology, Van-Nung University, Tao-Yuan 32061, Taiwan;
| | - Ren-Jei Chung
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 10608, Taiwan;
| | - Chih-Wei Chiu
- Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan; (J.-T.S.); (J.-W.L.)
- Correspondence: ; Tel.: +886-2-2737-6521; Fax: +886-2-2737-6544
| |
Collapse
|
37
|
Cao Y, Wang Q, Ruan Y, Wu R, Chen L, Zhang K, Lam PKS. Intra-day microplastic variations in wastewater: A case study of a sewage treatment plant in Hong Kong. MARINE POLLUTION BULLETIN 2020; 160:111535. [PMID: 32805536 DOI: 10.1016/j.marpolbul.2020.111535] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Revised: 07/27/2020] [Accepted: 07/30/2020] [Indexed: 05/26/2023]
Abstract
Wastewater treatment plants (WWTPs) in coastal region play a primary role in transferring microplastics into the marine environment. Wastewater is closely related to anthropogenic activities, thus the intra-day variation of abundance of microplastics in the influent should be large and could have significant impact on their estimation of the daily mass load. In this study, a 2-hour interval sampling campaign was conducted at a secondary WWTP in Hong Kong to investigate the intra-day variations and daily loads of microplastics in influent. Results show that the average microplastic abundances increased from 7.1 ± 6.0 to 12.8 ± 5.8 particles/L over time, with predominant particle sizes ranging 1-5 mm. Approximately 80% of the microplastics in samples collected from 9:30-15:00 were polyethylene and polyester, while most samples collected at 17:00 were polypropylene and polyurethane. Microplastic loads exhibited large intra-day variations ranging 6.60 × 108-1.16 × 109 particles/day, indicating that calculated daily microplastic loads based on a specific sampling period may inaccurately estimate the actual daily load.
Collapse
Affiliation(s)
- Yaru Cao
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Hong Kong, China; Department of Chemistry, City University of Hong Kong, Hong Kong, China
| | - Qi Wang
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Hong Kong, China; Department of Chemistry, City University of Hong Kong, Hong Kong, China; Research Centre for the Oceans and Human Health, The City University of Hong Kong Shenzhen Research Institute, Shenzhen, China
| | - Yuefei Ruan
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Hong Kong, China; Research Centre for the Oceans and Human Health, The City University of Hong Kong Shenzhen Research Institute, Shenzhen, China; Southern Marine Science and Engineering Guangdong Laboratory (Zhuhai), Zhuhai, China
| | - Rongben Wu
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Hong Kong, China; Department of Chemistry, City University of Hong Kong, Hong Kong, China; Research Centre for the Oceans and Human Health, The City University of Hong Kong Shenzhen Research Institute, Shenzhen, China
| | - Luoluo Chen
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Hong Kong, China
| | - Kai Zhang
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Hong Kong, China; Department of Chemistry, City University of Hong Kong, Hong Kong, China; Research Centre for the Oceans and Human Health, The City University of Hong Kong Shenzhen Research Institute, Shenzhen, China; Southern Marine Science and Engineering Guangdong Laboratory (Zhuhai), Zhuhai, China.
| | - Paul K S Lam
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Hong Kong, China; Department of Chemistry, City University of Hong Kong, Hong Kong, China; Research Centre for the Oceans and Human Health, The City University of Hong Kong Shenzhen Research Institute, Shenzhen, China; Southern Marine Science and Engineering Guangdong Laboratory (Zhuhai), Zhuhai, China
| |
Collapse
|
38
|
Villani M, Bertoglio F, Restivo E, Bruni G, Iervese S, Arciola CR, Carulli F, Iannace S, Bertini F, Visai L. Polyurethane-Based Coatings with Promising Antibacterial Properties. MATERIALS 2020; 13:ma13194296. [PMID: 32993029 PMCID: PMC7579457 DOI: 10.3390/ma13194296] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/25/2020] [Revised: 09/21/2020] [Accepted: 09/23/2020] [Indexed: 01/03/2023]
Abstract
In coatings technology, the possibility of introducing specific characteristics at the surface level allows for the manufacture of medical devices with efficient and prolonged antibacterial properties. This efficiency is often achieved by the use of a small amount of antibacterial molecules, which can fulfil their duty while limiting eventual releasing problems. The object of this work was the preparation and characterization of silver, titanium dioxide and chitosan polyurethane-based coatings. Coatings with the three antibacterials were prepared using different deposition techniques, using a brush or a bar coater automatic film applicator, and compared to solvent casted films prepared with the same components. For silver containing materials, an innovative strategy contemplating the use and preparation of silver nanoparticles in a single step-method was employed. This preparation was obtained starting from a silver precursor and using a single compound as the reducing agent and stabilizer. Ultraviolet-visible spectroscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy, contact angle measurements and adhesion test experiments were used to characterize the prepared coatings. Promising antibacterial properties, measured via direct and indirect methods, were registered for all the silver-based materials.
Collapse
Affiliation(s)
- Maurizio Villani
- Istituto di Scienze e Tecnologie Chimiche “Giulio Natta”—CNR, Via A. Corti 12, 20133 Milano, Italy; (F.C.); (S.I.); (F.B.)
- Correspondence: or (M.V.); (L.V.)
| | - Federico Bertoglio
- Department of Molecular Medicine (DMM), Center for Health Technologies (CHT), UdR INSTM, University of Pavia, Viale Taramelli 3/B, 27100 Pavia, Italy; (F.B.); (E.R.); (S.I.)
| | - Elisa Restivo
- Department of Molecular Medicine (DMM), Center for Health Technologies (CHT), UdR INSTM, University of Pavia, Viale Taramelli 3/B, 27100 Pavia, Italy; (F.B.); (E.R.); (S.I.)
| | - Giovanna Bruni
- Center for Colloid and Surfaces Science (C.S.G.I.), Department of Chemistry, Physical Chemistry Section, University of Pavia, viale Taramelli 16, 27100 Pavia, Italy;
| | - Stefano Iervese
- Department of Molecular Medicine (DMM), Center for Health Technologies (CHT), UdR INSTM, University of Pavia, Viale Taramelli 3/B, 27100 Pavia, Italy; (F.B.); (E.R.); (S.I.)
| | - Carla Renata Arciola
- Department of Experimental, Diagnostic and Specialty Medicine (DIMES), University of Bologna, Via S. Giacomo, 14, 40126 Bologna, Italy;
- Laboratorio di Patologia delle Infezioni Associate all’Impianto, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy
| | - Francesco Carulli
- Istituto di Scienze e Tecnologie Chimiche “Giulio Natta”—CNR, Via A. Corti 12, 20133 Milano, Italy; (F.C.); (S.I.); (F.B.)
| | - Salvatore Iannace
- Istituto di Scienze e Tecnologie Chimiche “Giulio Natta”—CNR, Via A. Corti 12, 20133 Milano, Italy; (F.C.); (S.I.); (F.B.)
| | - Fabio Bertini
- Istituto di Scienze e Tecnologie Chimiche “Giulio Natta”—CNR, Via A. Corti 12, 20133 Milano, Italy; (F.C.); (S.I.); (F.B.)
| | - Livia Visai
- Department of Molecular Medicine (DMM), Center for Health Technologies (CHT), UdR INSTM, University of Pavia, Viale Taramelli 3/B, 27100 Pavia, Italy; (F.B.); (E.R.); (S.I.)
- Department of Occupational Medicine, Toxicology and Environmental Risks, Istituti Clinici Scientifici Maugeri S.p.A Società Benefit, IRCCS, Via S. Boezio, 28, 27100 Pavia, Italy
- Correspondence: or (M.V.); (L.V.)
| |
Collapse
|
39
|
Zia A, Pentzer E, Thickett S, Kempe K. Advances and Opportunities of Oil-in-Oil Emulsions. ACS APPLIED MATERIALS & INTERFACES 2020; 12:38845-38861. [PMID: 32805925 DOI: 10.1021/acsami.0c07993] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Emulsions are mixtures of two immiscible liquids in which droplets of one are dispersed in a continuous phase of the other. The most common emulsions are oil-water systems, which have found widespread use across a number of industries, for example, in the cosmetic and food industries, and are also of advanced scientific interest. In addition, the past decade has seen a significant increase in both the design and application of nonaqueous emulsions. This has been primarily driven by developments in understanding the mechanism of effective stabilization of oil-in-oil (o/o) systems, either using block copolymers (BCPs) or solid (Pickering) particles with appropriate surface functionality. These systems, as highlighted in this review, have enabled emergent applications in areas such as pharmaceutical delivery, energy storage, and materials design (e.g., polymerization, monolith, and porous polymer synthesis). These o/o emulsions complement traditional emulsions that utilize an aqueous phase and allow the use of materials incompatible with water. We assess recent advances in the preparation and stabilization of o/o emulsions, focusing on the identity of the stabilizer (BCP or particle), the interplay between stabilizer and oils, and highlighting applications and opportunities associated with o/o emulsions.
Collapse
Affiliation(s)
- Aadarash Zia
- ARC Centre of Excellence in Convergent Bio-Nano Science & Technology and Drug Delivery Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia
| | - Emily Pentzer
- Department of Chemistry, Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77807, United States
| | - Stuart Thickett
- School of Natural Sciences (Chemistry), The University of Tasmania, Hobart, Tasmania 7001 Australia
| | - Kristian Kempe
- ARC Centre of Excellence in Convergent Bio-Nano Science & Technology and Drug Delivery Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia
- Materials Science and Engineering, Monash University, Clayton, Victoria 3800, Australia
| |
Collapse
|
40
|
Xu W, Zhang M, Liu Y, Zhang H, Chen M, Jiang H, Wang Y. Stress-Softening in Particle-Filled Polyurethanes under Cyclic Compressive Loading. Polymers (Basel) 2020; 12:polym12071588. [PMID: 32709010 PMCID: PMC7407950 DOI: 10.3390/polym12071588] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 07/13/2020] [Accepted: 07/14/2020] [Indexed: 01/13/2023] Open
Abstract
Elastomer compositions containing various particulate fillers can be formulated according to the specific functions required of them. Stress softening—which is also known as the Mullins effect—occurs during high loading and unloading paths in certain supramolecular elastomer materials. Previous experiments have revealed that the load–displacement response differs according to the filler used, demonstrating an unusual model of correspondence between the constitutive materials. Using a spherical indentation method and numerical simulation, we investigated the Mullins effect on polyurethane (PU) compositions subjected to cyclic uniaxial compressive load. The PU compositions comprised rigid particulate fillers (i.e., nano-silica and carbon black). The neo-Hooke model and the Ogden–Roxburgh Mullins model were used to describe the nonlinear deformation behavior of the soft materials. Based on finite element methods and parameter optimization, the load–displacement curves of various filled PUs were analyzed and fitted, enabling constitutive parameter prediction and inverse modeling. Hence, correspondence relationships between material components and constitutive parameters were established. Such relationships are instructive for the preparation of materials with specific properties. The method described herein is a more quantitative approach to the formulation of elastomer compositions comprising particulate fillers.
Collapse
Affiliation(s)
- Wenshuai Xu
- Key Laboratory of Microgravity, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China; (W.X.); (Y.L.); (Y.W.)
- School of Engineering Science, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Mangong Zhang
- Wuhan Second Ship Design and Research Institute, Wuhan 430064, China; (M.Z.); (H.Z.)
| | - Yu Liu
- Key Laboratory of Microgravity, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China; (W.X.); (Y.L.); (Y.W.)
- School of Engineering Science, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Hao Zhang
- Wuhan Second Ship Design and Research Institute, Wuhan 430064, China; (M.Z.); (H.Z.)
| | - Meng Chen
- Key Laboratory of Microgravity, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China; (W.X.); (Y.L.); (Y.W.)
- School of Engineering Science, University of Chinese Academy of Sciences, Beijing 100049, China
- Correspondence: (M.C.); (H.J.)
| | - Heng Jiang
- Key Laboratory of Microgravity, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China; (W.X.); (Y.L.); (Y.W.)
- School of Engineering Science, University of Chinese Academy of Sciences, Beijing 100049, China
- Correspondence: (M.C.); (H.J.)
| | - Yuren Wang
- Key Laboratory of Microgravity, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China; (W.X.); (Y.L.); (Y.W.)
- School of Engineering Science, University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|