1
|
Taymour N, Abd El-Fattah A, Kandil S, Fahmy AE, Al-Qahtani NH, Khaled A, Al-Dulaijan YA, Gepreel MAH. Revolutionizing Dental Polymers: The Versatility and Future Potential of Polyetheretherketone in Restorative Dentistry. Polymers (Basel) 2024; 17:80. [PMID: 39795483 PMCID: PMC11723045 DOI: 10.3390/polym17010080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2024] [Revised: 12/22/2024] [Accepted: 12/28/2024] [Indexed: 01/13/2025] Open
Abstract
Polyetheretherketone (PEEK) has emerged as a revolutionary material in modern dentistry because of its unique combination of mechanical strength, biocompatibility, and versatility. This literature review examines the current applications and future potential of PEEK in various dental disciplines. PEEK's favorable properties, including its low specific weight, high strength-to-weight ratio, and ability to be easily machined, have led to its adoption in prosthetics, implantology, and dental esthetic restorations. This material has shown promise for fabricating crowns, bridges, removable partial denture frameworks, and implant components. PEEK's radiolucency and bone-like elastic modulus make it particularly suitable for dental implants and abutments. Additionally, its resistance to degradation and compatibility with various surface treatments enhances its long-term performance in the oral environment. While challenges such as bonding to other dental materials and aesthetic limitations exist, ongoing research is addressing these issues through surface modifications and composite formulations. As the dental field continues to evolve, PEEK's adaptability and biocompatibility position it a key player in the development of next-generation dental materials and techniques, potentially transforming patient care and treatment outcomes in dentistry.
Collapse
Affiliation(s)
- Noha Taymour
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia;
| | - Ahmed Abd El-Fattah
- Department of Materials Science, Institute of Graduate Studies and Research, Alexandria University, El-Shatby, Alexandria 21526, Egypt or (A.A.E.-F.); (S.K.)
- Department of Chemistry, College of Science, University of Bahrain, Sakhir P.O. Box 32038, Bahrain
| | - Sherif Kandil
- Department of Materials Science, Institute of Graduate Studies and Research, Alexandria University, El-Shatby, Alexandria 21526, Egypt or (A.A.E.-F.); (S.K.)
| | - Amal E. Fahmy
- Department of Dental Materials, Faculty of Dentistry, Alexandria University, Azarita, Alexandria 21526, Egypt;
| | - Naif H. Al-Qahtani
- College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia;
| | - Abdulrahman Khaled
- Department of Materials Science, Institute of Graduate Studies and Research, Alexandria University, El-Shatby, Alexandria 21526, Egypt or (A.A.E.-F.); (S.K.)
| | - Yousif A. Al-Dulaijan
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia;
| | - Mohamed Abdel-Hady Gepreel
- Department of Materials Science and Engineering, Egypt-Japan University of Science and Technology (E-JUST), New Borg El-Arab City 21934, Egypt;
| |
Collapse
|
2
|
Karakaya K, Mutluay Ünal S. Evaluation of stress distribution of different marginal designs on PEEK and PEKK substructure materials, cortical and cancellous Bone:A finite element analysis. Comput Biol Med 2024; 178:108708. [PMID: 38861895 DOI: 10.1016/j.compbiomed.2024.108708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 06/01/2024] [Accepted: 06/03/2024] [Indexed: 06/13/2024]
Abstract
BACKGROUND High-performance polymers are used in different fixed prosthesis treatments due to their many advantages such as biocompatibility, shock absorption ability, high fracture resistance. The effects of marginal design on the forces on high-performance polymers are unknown. This study aimed was to investigate the stress distribution of different marginal designs on Polyetheretherketone (PEEK) and Polyetherketoneketone (PEKK) substructure materials, cortical bone and cancellous bone by finite element analysis. METHODS A first maxillary molar tooth was modeled in 3D using the "3D Complex Render" method. Considering the ideal preparation conditions (Taper angle was 6°, step depth was 1 mm, occlusal reduction was 2 mm), four different configurations were modeled by changing the marginal design (chamfer, deep chamfer, shoulder 90°, shoulder 135°). PEEK, PEKK substructure, and composite superstructure were designed on created models. A total of 150 N oblique force from two points and a total of 300 N vertical force from three points were applied from occlusall. and the maximum principal stress, minimum principal stress, von Mises stress findings in the cortical bone, spongiose bone, and substructure were examined. The study was carried out by static linear analysis with a three-dimensional finite element stress analysis method. RESULTS The highest maximum principal stress value in the cortical bone was observed when the PEEK + Shoulder 135° step at vertical force. The highest minimum principal stress value in the cortical bone was observed when the PEEK + Shoulder 90° step, and PEEK + deep chamfer step at oblique force. The highest maximum principal stress value in spongiose bone was observed when the PEEK + Shoulder 90° step. The highest minimum principal stress value in spongiose bone was observed when the PEEK + deep chamfer step at vertical force. The highest von Mises stress value in the substructure was observed when the PEKK + Deep chamfer step at oblique force. The lowest maximum principal stress value in the cortical bone was observed when the PEKK + Shoulder 135° step at oblique force. The lowest minimum principal stress value in the cortical bone was observed when the PEEK + Shoulder 135° step, and PEKK + shoulder 135° step at vertical force. The lowest maximum principal stress value in spongiose bone was observed when the PEEK + Shoulder 90° step. The lowest minimum principal stress value in spongiose bone was observed when the PEEK + Shoulder 135° step and PEKK + Shoulder 135° step at vertical force. The lowest von Mises stress value in the substructure was observed when the PEEK + Deep chamfer step at vertical force. CONCLUSION When cortical and spongiose bone stress were evaluated, no destructive stress was observed. Considering the stresses occurring in the substructure the highest stress was observed in the chamfer step.
Collapse
Affiliation(s)
- Kevser Karakaya
- Afyonkarahisar Health Sciences University, Faculty of Dentistry, Department of Prosthodontics, Afyonkarahisar, Turkey.
| | - Server Mutluay Ünal
- Afyonkarahisar Health Sciences University, Faculty of Dentistry, Department of Prosthodontics, Afyonkarahisar, Turkey.
| |
Collapse
|
3
|
Sultan SES, Salloum MG. Comparative Analysis of the Color Stability of Machined Denture Base Materials: An In-Vitro Approach. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES 2024; 16:S2482-S2484. [PMID: 39346189 PMCID: PMC11426752 DOI: 10.4103/jpbs.jpbs_332_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2024] [Revised: 04/03/2024] [Accepted: 04/09/2024] [Indexed: 10/01/2024] Open
Abstract
Background Color stability is a crucial aspect in the selection of denture base materials as it directly impacts the esthetic appeal and longevity of dental prostheses. This study aimed to compare the color stability of different denture base materials through an in vitro approach. Materials and Methods Three machined denture base materials including polymethyl methacrylate (PMMA), Acetal (AC), and polyether ether ketone (PEEK) were subjected to artificial aging using a xenon-arc lamp. Color measurements were taken before and after aging using a spectrophotometer. Statistical analysis was performed to determine any significant differences among the materials. Results The color stability of the denture base materials was quantitatively assessed using parameters such as ΔE values. PEEK exhibited the least color change (ΔE = 2.1 ± 0.3), followed by AC (ΔE = 3.5 ± 0.4), while PMMA showed the highest color change (ΔE = 5.9 ± 0.7). Conclusion In this in vitro study, PEEK demonstrated superior color stability compared to AC and PMMA denture base materials under artificial aging conditions. These findings emphasize the importance of material selection in achieving long-term esthetic outcomes in dental prostheses.
Collapse
Affiliation(s)
- Sherif El Sayed Sultan
- Department of Prosthetic Dental Sciences, College of Dentistry, Jouf University, Sakakah, Saudi Arabia
| | - Mahmoud Gamal Salloum
- Department of Substitutive Dental Sciences, College of Dentistry and Pharmacy, Buraydah Private Colleges, Buraydah, Saudi Arabia
| |
Collapse
|
4
|
Chang CL, Karmakar R, Mukundan A, Lu SH, Choomjinda U, Chen MM, Chen YL, Wang HC. Mechanical Integrity of All-on-Four Dental Implant Systems: Finite Element Simulation of Material Properties of Zirconia, Titanium, and PEEK. Open Dent J 2024; 18. [DOI: 10.2174/0118742106325708240614044708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2024] [Revised: 06/07/2024] [Accepted: 06/07/2024] [Indexed: 08/15/2024] Open
Abstract
Background
Dental implants are critical for restoring functionality and aesthetics in patients with missing teeth. The all-on-four treatment concept utilizes four dental implants to support a full-arch prosthesis. Material choice for these implants plays a crucial role in the long-term success of the treatment, affecting everything from biomechanical stability to osseointegration and patient comfort.
Aim
The purpose of this study is to analyze the biomechanical performance of three different materials used in all-on-four dental implant designs through finite element analysis (FEA). The aim is to determine which material optimally balances stress and deformation under various loading conditions.
Objective
The main objective of this research is to evaluate the effects of stress, strain, and deformation on all-on-four dental implants made from titanium, zirconia, and polyether ether ketone (PEEK). The study seeks to identify which material demonstrates the best mechanical properties under simulated functional loads.
Methods
A 3D model simulating the dental implants integrated with cancellous and cortical bone was developed. Finite element analysis was conducted to assess the biomechanical performance of the implants made from titanium, zirconia, and PEEK. A perpendicular load of 100 N was applied to the tips of the implants, followed by an oblique load of 100 N at a 30-degree angle, to simulate different chewing forces.
Results
The deformation analysis indicated that implants made of zirconia exhibited significantly lower maximum and average deformation compared to those made from titanium and PEEK. Although PEEK implants showed lower maximum and average stress, they did not perform well in stress dissipation compared to zirconia. Similar patterns of stress and deformation were observed under both perpendicular and oblique loading conditions.
Conclusion
Zirconia implants outperformed titanium and PEEK in terms of deformation and stress distribution under simulated loading conditions. This suggests that zirconia could be a superior material for all-on-four dental implants, offering better mechanical stability and potentially enhancing the longevity and success of dental restorations. Further clinical trials are recommended to validate these findings and assess the long-term outcomes of zirconia-based implants.
Collapse
|
5
|
Dobrota CT, Florea AD, Racz CP, Tomoaia G, Soritau O, Avram A, Benea HRC, Rosoiu CL, Mocanu A, Riga S, Kun AZ, Tomoaia-Cotisel M. Dynamics of Dental Enamel Surface Remineralization under the Action of Toothpastes with Substituted Hydroxyapatite and Birch Extract. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2038. [PMID: 38730845 PMCID: PMC11084803 DOI: 10.3390/ma17092038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 04/18/2024] [Accepted: 04/24/2024] [Indexed: 05/13/2024]
Abstract
To address tooth enamel demineralization resulting from factors such as acid erosion, abrasion, and chronic illness treatments, it is important to develop effective daily dental care products promoting enamel preservation and surface remineralization. This study focused on formulating four toothpastes, each containing calcined synthetic hydroxyapatite (HAP) in distinct compositions, each at 4%, along with 1.3% birch extract. Substitution elements were introduced within the HAP structure to enhance enamel remineralization. The efficacy of each toothpaste formulation was evaluated for repairing enamel and for establishing the dynamic of the remineralization. This was performed by using an in vitro assessment of artificially demineralized enamel slices. The structural HAP features explored by XRD and enamel surface quality by AFM revealed notable restorative properties of these toothpastes. Topographic images and the self-assembly of HAP nanoparticles into thin films on enamel surfaces showcased the formulations' effectiveness. Surface roughness was evaluated through statistical analysis using one-way ANOVA followed by post-test Bonferroni's multiple comparison test with a p value < 0.05 significance setting. Remarkably, enamel nanostructure normalization was observed within a short 10-day period of toothpaste treatment. Optimal remineralization for all toothpastes was reached after about 30 days of treatment. These toothpastes containing birch extract also have a dual function of mineralizing enamel while simultaneously promoting enamel health and restoration.
Collapse
Affiliation(s)
- Cristina Teodora Dobrota
- Research Center of Excellence in Physical Chemistry, Faculty of Chemistry and Chemical Engineering, Babeş-Bolyai University, 11 Arany Janos St., 400028 Cluj-Napoca, Romania; (C.T.D.); (A.-D.F.); (C.-P.R.); (A.A.); (A.M.); (S.R.); (A.-Z.K.)
- Department of Molecular Biology and Biotechnology, Faculty of Biology and Geology, Babeş-Bolyai University, 44 Republicii St., 400015 Cluj-Napoca, Romania;
| | - Alexandra-Diana Florea
- Research Center of Excellence in Physical Chemistry, Faculty of Chemistry and Chemical Engineering, Babeş-Bolyai University, 11 Arany Janos St., 400028 Cluj-Napoca, Romania; (C.T.D.); (A.-D.F.); (C.-P.R.); (A.A.); (A.M.); (S.R.); (A.-Z.K.)
| | - Csaba-Pal Racz
- Research Center of Excellence in Physical Chemistry, Faculty of Chemistry and Chemical Engineering, Babeş-Bolyai University, 11 Arany Janos St., 400028 Cluj-Napoca, Romania; (C.T.D.); (A.-D.F.); (C.-P.R.); (A.A.); (A.M.); (S.R.); (A.-Z.K.)
| | - Gheorghe Tomoaia
- Department of Orthopedics and Traumatology, Iuliu Hatieganu University of Medicine and Pharmacy, 47 General Traian Mosoiu St., 400132 Cluj-Napoca, Romania; (G.T.)
- Academy of Romanian Scientists, 3 Ilfov St., 050044 Bucharest, Romania
| | - Olga Soritau
- Oncology Institute of Cluj-Napoca, 34-36 Republicii St., 400015 Cluj-Napoca, Romania;
| | - Alexandra Avram
- Research Center of Excellence in Physical Chemistry, Faculty of Chemistry and Chemical Engineering, Babeş-Bolyai University, 11 Arany Janos St., 400028 Cluj-Napoca, Romania; (C.T.D.); (A.-D.F.); (C.-P.R.); (A.A.); (A.M.); (S.R.); (A.-Z.K.)
| | - Horea-Rares-Ciprian Benea
- Department of Orthopedics and Traumatology, Iuliu Hatieganu University of Medicine and Pharmacy, 47 General Traian Mosoiu St., 400132 Cluj-Napoca, Romania; (G.T.)
| | - Cristina Lavinia Rosoiu
- Department of Molecular Biology and Biotechnology, Faculty of Biology and Geology, Babeş-Bolyai University, 44 Republicii St., 400015 Cluj-Napoca, Romania;
| | - Aurora Mocanu
- Research Center of Excellence in Physical Chemistry, Faculty of Chemistry and Chemical Engineering, Babeş-Bolyai University, 11 Arany Janos St., 400028 Cluj-Napoca, Romania; (C.T.D.); (A.-D.F.); (C.-P.R.); (A.A.); (A.M.); (S.R.); (A.-Z.K.)
| | - Sorin Riga
- Research Center of Excellence in Physical Chemistry, Faculty of Chemistry and Chemical Engineering, Babeş-Bolyai University, 11 Arany Janos St., 400028 Cluj-Napoca, Romania; (C.T.D.); (A.-D.F.); (C.-P.R.); (A.A.); (A.M.); (S.R.); (A.-Z.K.)
- Academy of Romanian Scientists, 3 Ilfov St., 050044 Bucharest, Romania
| | - Attila-Zsolt Kun
- Research Center of Excellence in Physical Chemistry, Faculty of Chemistry and Chemical Engineering, Babeş-Bolyai University, 11 Arany Janos St., 400028 Cluj-Napoca, Romania; (C.T.D.); (A.-D.F.); (C.-P.R.); (A.A.); (A.M.); (S.R.); (A.-Z.K.)
| | - Maria Tomoaia-Cotisel
- Research Center of Excellence in Physical Chemistry, Faculty of Chemistry and Chemical Engineering, Babeş-Bolyai University, 11 Arany Janos St., 400028 Cluj-Napoca, Romania; (C.T.D.); (A.-D.F.); (C.-P.R.); (A.A.); (A.M.); (S.R.); (A.-Z.K.)
- Academy of Romanian Scientists, 3 Ilfov St., 050044 Bucharest, Romania
| |
Collapse
|
6
|
Kaya N, Sasany R, Yanıkoglu N, Tosun B. Investigation of color and physicomechanical properties of peek and pekk after storage in a different medium. Sci Rep 2024; 14:5357. [PMID: 38438417 PMCID: PMC10912655 DOI: 10.1038/s41598-024-54695-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Accepted: 02/15/2024] [Indexed: 03/06/2024] Open
Abstract
The aim of this study is to assess color stability, solubility, and water sorption on polyether ether ketone (PEEK) and polyether ketone ketone (PEKK) after immersion in different storage conditions. Material and Methods Ninety disc-shaped specimens (8 × 2) were obtained from CAD/CAM blocks [PEEK (n = 45) and PEKK (n = 45)]. Before immersion, baseline color value data were recorded with a spectrophotometer. The specimens were soaked in three solutions red wine, coffee, and distilled water at 37 °C for 28 days. Following immersion, color values were remeasured, and color-change values (ΔE) were calculated. Water sorption and solubility were assessed by mass gain or loss after storage in water for 28 days. The Kruskal-Wallis and the Mann-Whitney U test were used for analysis (P = 0.05). Results ΔE00 between PEEK and PEKK was significantly different statistically (P < 0.001). PEEK presented higher water sorption than PEKK (P = 0.005). The difference in solubility between PEEK and PEKK was not statistically significant (P = 0.163). The materials and storage medium types had a statistically significant impact (P = 0.100). In terms of staining potential, the solutions tested in this experiment were ranked as: coffee > red wine > distilled water. The results of this study demonstrated that PEKK was more successful in polymer-containing CAD/CAM materials as it exhibited less color change and water absorption.
Collapse
Affiliation(s)
- Nihan Kaya
- Department of Prosthodontics, Faculty of Dentistry, University of Giresun, Giresun, Turkey
| | - Rafat Sasany
- Department of Prosthodontics, Faculty of Dentistry, University of Biruni, İstanbul, Turkey.
| | - Nuran Yanıkoglu
- Department of Prosthodontics, Faculty of Dentistry, University of Ataturk, Erzurum, Turkey
| | - Busra Tosun
- Department of Prosthodontics, Faculty of Dentistry, University of Abant İzzet Baysal, Bolu, Turkey
| |
Collapse
|
7
|
N J, Ahmed N, Rattan R. Evaluation and Assessment of the Colour Stability of Modified Polymethyl Methacrylate Denture Base Materials and Polyether Ether Ketone in a Cast Partial Denture Framework: An In-Vitro Study. Cureus 2023; 15:e48189. [PMID: 38054115 PMCID: PMC10694397 DOI: 10.7759/cureus.48189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Accepted: 11/01/2023] [Indexed: 12/07/2023] Open
Abstract
Background One of the frequent aesthetic issues patients confront is the loss of colour and lifeless appearance of the dentures of the base materials of their dentures after regular use. This leads to a lack of motivation to use the denture regularly. Due to the drawbacks of conventional PMMA, polyether ether ketone (PEEK) and newer polymethyl methacrylate (PMMA)-based materials have now started being used in cast partial denture frameworks due to their superior physical and biological properties. The lack of long-lasting colour is one of the main reasons for the repeat of dental prostheses. Hence, the need for the study is to help clinicians decide which would be the most suitable denture base material to be used based on colour stability. Aim To assess and compare the colour stability of PEEK, polyan, and biodentaplast denture base materials (DBMs) upon staining with distilled water, tea, coffee, and turmeric solutions after one day, seven days, and 30 days. Methods A total of 20 cuboidal specimens were constructed and immersed in distilled water, tea, coffee, and turmeric (five specimens of each material in each solution, a total of 60 specimens): Group 1: PEEK, Group 2: polyan, Group 3: biodentaplast. All specimens were subjected to colour measurements before exposure to beverage solutions, after 24 hours, on the seventh day and 30th day with a colour reflectance spectrophotometer with computer software. A one-way ANOVA test followed by post hoc Tukey's honestly significant difference (HSD) was performed for comparison of colour stability between the DBMs, revealing a significant difference between PEEK and polyan and PEEK and biodentaplast. Polyan showed the highest delta E values, followed by biodentaplast and PEEK. A two-way ANOVA test, followed by Tukey's HSD post hoc, was done to compare the staining ability of various staining solutions. Turmeric had the highest delta E values, followed by coffee, tea, and distilled water. Data were assessed using Statistical Product and Service Solutions (SPSS, version 23) (IBM SPSS Statistics for Windows, Armonk, NY) software. Results The highest mean delta E value at T1 was seen in biodentaplast immersed in turmeric (12.3900+/-0.442), and the least value at T1 was obtained for PEEK immersed in distilled water (0.4460+/-0.036). The highest mean delta E value at T2 was seen in polyan immersed in turmeric (13.0160+/-0.28962), and the least value at T2 was obtained for PEEK immersed in distilled water (0.5860+/-0.051). At T3, the highest mean delta E value was seen in polyan immersed in turmeric (16.8600+/-0.49845), and the least value at T3 was obtained for PEEK immersed in distilled water (0.700+/-0.037). Conclusion PEEK had the highest colour stability when compared with polyan and biodentaplast.
Collapse
Affiliation(s)
- Joshua N
- Department of Prosthodontics, Saveetha Dental College, Saveetha Institute of Medical and Technical Sciences (SIMATS) Saveetha University, Chennai, IND
| | - Nabeel Ahmed
- Department of Prosthodontics, Saveetha Dental College, Saveetha Institute of Medical and Technical Sciences (SIMATS) Saveetha University, Chennai, IND
| | - Rekha Rattan
- Department of Prosthodontics, Saveetha Dental College, Saveetha Institute of Medical and Technical Sciences (SIMATS) Saveetha University, Chennai, IND
| |
Collapse
|
8
|
Le Bars P, Bandiaky ON, Le Guéhennec L, Clouet R, Kouadio AA. Different Polymers for the Base of Removable Dentures? Part I: A Narrative Review of Mechanical and Physical Properties. Polymers (Basel) 2023; 15:3495. [PMID: 37688123 PMCID: PMC10490543 DOI: 10.3390/polym15173495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 08/14/2023] [Accepted: 08/17/2023] [Indexed: 09/10/2023] Open
Abstract
Even before considering their introduction into the mouth, the choice of materials for the optimization of the prosthesis depends on specific parameters such as their biocompatibility, solidity, resistance, and longevity. In the first part of this two-part review, we approach the various mechanical characteristics that affect this choice, which are closely related to the manufacturing process. Among the materials currently available, it is mainly polymers that are suitable for this use in this field. Historically, the most widely used polymer has been polymethyl methacrylate (PMMA), but more recently, polyamides (nylon) and polyether ether ketone (PEEK) have provided interesting advantages. The incorporation of certain molecules into these polymers will lead to modifications aimed at improving the mechanical properties of the prosthetic bases. In the second part of the review, the safety aspects of prostheses in the oral ecosystem (fragility of the undercuts of soft/hard tissues, neutral pH of saliva, and stability of the microbiota) are addressed. The microbial colonization of the prosthesis, in relation to the composition of the material used and its surface conditions (roughness, hydrophilicity), is of primary importance. Whatever the material and manufacturing process chosen, the coating or finishes dependent on the surface condition remain essential (polishing, non-stick coating) for limiting microbial colonization. The objective of this narrative review is to compile an inventory of the mechanical and physical properties as well as the clinical conditions likely to guide the choice between polymers for the base of removable prostheses.
Collapse
Affiliation(s)
- Pierre Le Bars
- Department of Prosthetic Dentistry, Faculty of Dentistry, Nantes University, 1 Place Alexis Ricordeau, 44042 Nantes, France; (L.L.G.); (R.C.); (A.A.K.)
- Oniris, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, RMeS, Nantes Université, UMR 1229, 44000 Nantes, France;
| | - Octave Nadile Bandiaky
- Oniris, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, RMeS, Nantes Université, UMR 1229, 44000 Nantes, France;
| | - Laurent Le Guéhennec
- Department of Prosthetic Dentistry, Faculty of Dentistry, Nantes University, 1 Place Alexis Ricordeau, 44042 Nantes, France; (L.L.G.); (R.C.); (A.A.K.)
- Oniris, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, RMeS, Nantes Université, UMR 1229, 44000 Nantes, France;
| | - Roselyne Clouet
- Department of Prosthetic Dentistry, Faculty of Dentistry, Nantes University, 1 Place Alexis Ricordeau, 44042 Nantes, France; (L.L.G.); (R.C.); (A.A.K.)
- Oniris, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, RMeS, Nantes Université, UMR 1229, 44000 Nantes, France;
| | - Alain Ayepa Kouadio
- Department of Prosthetic Dentistry, Faculty of Dentistry, Nantes University, 1 Place Alexis Ricordeau, 44042 Nantes, France; (L.L.G.); (R.C.); (A.A.K.)
- Department of Prosthetic Dentistry, Faculty of Dentistry, University Hospital Center, Abidjan P.O. Box 612, Côte d’Ivoire
| |
Collapse
|
9
|
He Z, Wu Q, Zhang N, Yang X, Lu Y, Yan P, Yue L, Yu H. A digital chairside repair protocol for removable partial dentures with polyetheretherketone frameworks. J Prosthet Dent 2023:S0022-3913(23)00486-9. [PMID: 37604753 DOI: 10.1016/j.prosdent.2023.07.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 07/09/2023] [Accepted: 07/11/2023] [Indexed: 08/23/2023]
Abstract
Polyetheretherketone (PEEK) has become popular for removable partial denture (RPD) frameworks but reports on their clinical follow-up and repair are lacking. Two defective PEEK-framework RPDs were repaired with computer-aided design and manufacturing technology, saving costs and time and simplifying the treatment process.
Collapse
Affiliation(s)
- Zijing He
- Graduate student, Department of Prosthodontics, State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China
| | - Qin Wu
- Graduate student, Department of Prosthodontics, State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China
| | - Na Zhang
- Graduate student, Department of Prosthodontics, State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China
| | - Xingqiang Yang
- Technician, Department of Dental Technology, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China
| | - Yuqing Lu
- Graduate student, Department of Prosthodontics, State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China
| | - Pengtao Yan
- Graduate student, R&D Department, Jilin University, Sion-Dentex Co., Ltd, Changchun, PR China
| | - Li Yue
- Senior Technician, Department of Dental Technology, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China
| | - Haiyang Yu
- Professor, Department of Prosthodontics, State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China..
| |
Collapse
|
10
|
Lu WJ, Chen WC, Srimaneepong V, Chen CS, Huang CH, Lin HC, Tung OH, Huang HH. Fracture Characteristics of Commercial PEEK Dental Crowns: Combining the Effects of Aging Time and TiO 2 Content. Polymers (Basel) 2023; 15:2720. [PMID: 37376366 DOI: 10.3390/polym15122720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 06/16/2023] [Accepted: 06/16/2023] [Indexed: 06/29/2023] Open
Abstract
Polyetheretherketone (PEEK) is an emerging thermoplastic polymer with good mechanical properties and an elastic modulus similar to that of alveolar bone. PEEK dental prostheses for computer-aided design/computer-aided manufacturing (CAD/CAM) systems on the market often have additives of titanium dioxide (TiO2) to strengthen their mechanical properties. However, the effects of combining aging, simulating a long-term intraoral environment, and TiO2 content on the fracture characteristics of PEEK dental prostheses have rarely been investigated. In this study, two types of commercially available PEEK blocks, containing 20% and 30% TiO2, were used to fabricate dental crowns by CAD/CAM systems and were aged for 5 and 10 h based on the ISO 13356 specifications. The compressive fracture load values of PEEK dental crowns were measured using a universal test machine. The morphology and crystallinity of the fracture surface were analyzed by scanning electron microscopy and an X-ray diffractometer, respectively. Statistical analysis was performed using the paired t-test (α = 0.05). Results showed no significant difference in the fracture load value of the test PEEK crowns with 20% and 30% TiO2 after 5 or 10 h of aging treatment; all test PEEK crowns have satisfactory fracture properties for clinical applications. Fracture surface analysis revealed that all test crowns fractured from the lingual side of the occlusal surface, with the fracture extending along the lingual sulcus to the lingual edge, showing a feather shape at the middle part of the fracture extension path and a coral shape at the end of the fracture. Crystalline analysis showed that PEEK crowns, regardless of aging time and TiO2 content, remained predominantly PEEK matrix and rutile phase TiO2. We would conclude that adding 20% or 30% TiO2 to PEEK crowns may have been sufficient to improve the fracture properties of PEEK crowns after 5 or 10 h of aging. Aging times below 10 h may still be safe for reducing the fracture properties of TiO2-containing PEEK crowns.
Collapse
Affiliation(s)
- Wen-Ju Lu
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
| | - Wei-Cheng Chen
- Department of Medicine, MacKay Medical College, New Taipei City 252, Taiwan
- Division of Sports Medicine & Surgery, Department of Orthopedic Surgery, MacKay Memorial Hospital, Taipei 104, Taiwan
| | - Viritpon Srimaneepong
- Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok 10330, Thailand
| | - Chiang-Sang Chen
- Department of Orthopedic Surgery, Far Eastern Memorial Hospital, New Taipei City 220, Taiwan
- Department of Materials and Textiles, Asia Eastern University of Science and Technology, New Taipei City 220, Taiwan
| | - Chang-Hung Huang
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Medical Research, MacKay Memorial Hospital, Taipei 251, Taiwan
| | - Hui-Ching Lin
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Stomatology, Taipei City Hospital, Zhongxing Branch, Taipei 103, Taiwan
- General Education Center, University of Taipei, Taipei 106, Taiwan
| | - Oi-Hong Tung
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Stomatology, Taipei Veterans General Hospital, Taipei 112, Taiwan
| | - Her-Hsiung Huang
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Stomatology, Taipei Veterans General Hospital, Taipei 112, Taiwan
- Institute of Oral Biology, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Medical Research, China Medical University Hospital, China Medical University, Taichung 404, Taiwan
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung 413, Taiwan
- School of Dentistry, Kaohsiung Medical University, Kaohsiung 807, Taiwan
- Department of Education and Research, Taipei City Hospital, Taipei 103, Taiwan
| |
Collapse
|
11
|
Gouda A, Sherif A, Wahba M, Morsi T. Effect of veneering material type and thickness ratio on flexural strength of bi-layered PEEK restorations before and after thermal cycling. Clin Oral Investig 2023; 27:2629-2639. [PMID: 36602589 PMCID: PMC10264476 DOI: 10.1007/s00784-022-04829-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Accepted: 12/18/2022] [Indexed: 01/06/2023]
Abstract
OBJECTIVE The purpose of this study was evaluating the biaxial strength of bi-layered PEEK restorations before and after aging using different veneering materials in different thickness ratios. MATERIAL AND METHODS Ninety specimens of thickness 1.5 mm were divided into three groups according to their veneering material. Group (CAD LD): BioHPP discs veneered with CAD milled lithium disilicate (n=30), group (CAD C): BioHPP discs veneered with CAD milled composite (n=30), and group (LC): BioHPP discs veneered with conventionally layered composite (n=30). Each group was subdivided into 3 subgroups (n=10) according to the different thickness ratios between the core and the veneering material (TC:TV). Subgroup 1: TC:TV=1:0.5, subgroup 2: TC:TV=0.7:0.8, and subgroup 3: TC:TV=0.5:1. Half of the specimens of each subgroup were subjected to thermocycling, and the bi-axial flexural strength of all specimens was tested before and after aging. Three-way ANOVA followed by Bonferroni's post hoc test were used for data analysis. The significance level was set at P ≤ 0.05. RESULTS Material, thickness ratio, and aging all had a significant effect on biaxial flexural strength. (LC) group had the highest biaxial flexural strength. TC:TV=0.5:1 showed the lowest biaxial flexural strength. All groups showed significant decrease in biaxial flexural strength after aging. CONCLUSIONS Veneering material for PEEK together with the thickness ratio between the core and veneering material greatly affect the flexural strength of bi-layered restorations. Thermocycling negatively impacts the flexural strength of PEEK bi-layered restorations. CLINICAL SIGNIFICANCE According to the results of that study, PEEK cores are best veneered with conventionally layered composite with core to veneering thickness ratio being 1:0.5.
Collapse
Affiliation(s)
- Ahmed Gouda
- Postgraduate Student, Faculty of Oral and Dental Medicine, Future University in Egypt, Cairo, Egypt
| | - Ashraf Sherif
- Fixed Prosthodontics Department, Faculty of Oral and Dental Medicine, Future University in Egypt, Cairo, Egypt
| | - Mennatallah Wahba
- Fixed Prosthodontics Department, Faculty of Oral and Dental Medicine, Future University in Egypt, Cairo, Egypt
| | - Tarek Morsi
- Fixed Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
- Vice Dean Postgraduate Affairs. Faculty of Oral and Dental Medicine, Misr International University, Cairo, Egypt
| |
Collapse
|
12
|
Toma FR, Moleriu LC, Porojan L. Micro-CT Marginal and Internal Fit Evaluation of CAD/CAM High-Performance Polymer Onlay Restorations. Polymers (Basel) 2023; 15:polym15071715. [PMID: 37050329 PMCID: PMC10096728 DOI: 10.3390/polym15071715] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 03/20/2023] [Accepted: 03/27/2023] [Indexed: 04/14/2023] Open
Abstract
(1) Background: The use of high-performance polymers for fixed restorations requires additional studies regarding their adaptability and processing with CAD/CAM technology. This in vitro study aims to assess the marginal and internal fit of PEEK and PEKK materials using microcomputed tomography. (2) Methods: Twenty-four (n = 8) MOD onlays made of PEKK (Pekkton ivory), unmodified PEEK (Juvora medical), and modified PEEK (BioHPP) were investigated. A typodont mandibular left first molar was scanned to achieve 24 resin, 3D printed abutment teeth. The onlays were fabricated with a five-axis milling machine, and after cementation of the specimens, the marginal (MG) and internal gaps (IG) were evaluated at twelve points in the mesio-distal section and thirteen points in the bucco-lingual section using microcomputed tomography. For statistical data analysis, Wilcoxon signed-rank/paired Student t-Test, Mann-Whitney/unpaired Student t-Test, and one-way ANOVA test were applied. (3) Results: Significant differences (p < 0.05; α = 0.05) were reported between the MG and IG for each material for all three polymers and also among two materials in terms of the MG and IG (except Juvora-BioHPP). The highest IG values were recorded in angular areas (axio-gingival line angle) in the mesio-distal section for all the polymers. (4) Conclusions: For all the materials, MG < IG. The type of polymer influenced the adaptability; the lowest marginal and internal gap mean values were recorded for BioHPP. The analyzed polymer used for onlays are clinically acceptable in terms of adaptability.
Collapse
Affiliation(s)
- Flavia Roxana Toma
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, "Victor Babeș" University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania
| | - Lavinia Cristina Moleriu
- Department of Functional Science, "Victor Babeș" University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania
| | - Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, "Victor Babeș" University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania
| |
Collapse
|
13
|
Wiessner A, Wassmann T, Wiessner JM, Schubert A, Wiechens B, Hampe T, Bürgers R. In Vivo Biofilm Formation on Novel PEEK, Titanium, and Zirconia Implant Abutment Materials. Int J Mol Sci 2023; 24:ijms24021779. [PMID: 36675292 PMCID: PMC9865206 DOI: 10.3390/ijms24021779] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 12/16/2022] [Accepted: 01/11/2023] [Indexed: 01/18/2023] Open
Abstract
The formation of biofilms on the surface of dental implants and abutment materials may lead to peri-implantitis and subsequent implant failure. Recently, innovative materials such as polyether-ether-ketone (PEEK) and its modifications have been used as abutment materials. However, there is limited knowledge on microbial adhesion to PEEK materials. The aim of this in vivo study was to investigate biofilm formation on the surface of conventional (titanium and zirconia) and PEEK implant abutment materials. Split specimens of titanium, zirconia, PEEK, and modified PEEK (PEEK-BioHPP) were manufactured, mounted in individual removable acrylic upper jaw splints, and worn by 20 healthy volunteers for 24 h. The surface roughness was determined using widefield confocal microscopy. Biofilm accumulation was investigated by fluorescence microscopy and quantified by imaging software. The surface roughness of the investigated materials was <0.2 µm and showed no significant differences between the materials. Zirconia showed the lowest biofilm formation, followed by titanium, PEEK, and PEEK-BioHPP. Differences were significant (p < 0.001) between the investigated materials, except for the polyether-ether-ketones. Generally, biofilm formation was significantly higher (p < 0.05) in the posterior region of the oral cavity than in the anterior region. The results of the present study show a material-dependent susceptibility to biofilm formation. The risk of developing peri-implantitis may be reduced by a specific choice of abutment material.
Collapse
Affiliation(s)
- Andreas Wiessner
- Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany
| | - Torsten Wassmann
- Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany
- Correspondence:
| | - Johanna Maria Wiessner
- Department of Orthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany
| | - Andrea Schubert
- Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany
| | - Bernhard Wiechens
- Department of Orthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany
| | - Tristan Hampe
- Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany
| | - Ralf Bürgers
- Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany
| |
Collapse
|
14
|
Demirci F, Bahce E. The effects of HAp coating layer on mechanical and optical properties at bonding interface of high-performance polymers. J Mech Behav Biomed Mater 2023; 137:105539. [PMID: 36343522 DOI: 10.1016/j.jmbbm.2022.105539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 10/17/2022] [Accepted: 10/19/2022] [Indexed: 11/06/2022]
Abstract
PURPOSE The effect of hydroxyapatite (HAp) coating layer on mechanical and optical properties at bonding interface of high-performance polymers (HPPs) used in computer-aided design (CAD)/computer-aided manufacture (CAM) technology was investigated in this in vitro study. MATERIALS AND METHODS Two hundred-twenty specimens were divided into two material groups (n = 110): polyetheretherketone (PEEK, KERA® starPEEK) and polyetherketoneketone (PEKK, Pekkton® ivory). For mechanical testing, each group was divided into five surface pretreatment subgroups and a control group (n = 10): HAp coating (1%,3%, 5%, and 10% concentrations) and sandblasting with 110-μm Al2O3 particles. For optical testing, each group was divided into five subgroups (n = 10): HAp coating (1%, 3%, 5%, and 10% concentrations) and control. The effects of the HAp coating on the optical changes and shear bond strength (SBS) of the specimens were investigated. Data was statistically analyzed by one-way ANOVA and Tukey's post-hoc test. Failure modes and surface properties of the specimens were examined by scanning electron microscopy (SEM) and coupled electron dispersive spectroscopy (EDS). RESULTS Average translucency and color change values increased with increasing HAp coating concentration in HPPs. As a result of the data, statistically significant differences were observed in terms of the effect of the HAp coating on SBS of HPPs (p < 0.05). Failure modes were examined, and mixed failure mode was observed. CONCLUSION HAp coating can contribute to the improvement of both the optical properties and bond strength of the HPPs to resin composite. CLINICAL SIGNIFICANCE Adhesion and color problems of high performance polymers are still under discussion. In order to solve these problems, generally focused on surface modifications of these polymers, but the effect of the HAp coating has not been investigated.
Collapse
Affiliation(s)
- Fatih Demirci
- Department of Prosthodontics, Faculty of Dentistry, Inonu University, Malatya, 44280, Turkey
| | - Erkan Bahce
- Department of Mechanical Engineering, Faculty of Engineering, Inonu University, Malatya, Turkey.
| |
Collapse
|
15
|
Al Ahmari NM, Alahmari MA, Al Moaleem MM, Alshahrani RSA, Alqahtani FF, Mohammed WS, Al-Makramani BMA, Mehta V, Meto A, Meto A. Physical, Optical, and Mechanical Properties of Ceramic Materials after Coffee Immersion and Evaluation of Cleaning Impact with Different Oral Hygiene Tools. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:15047. [PMID: 36429767 PMCID: PMC9690395 DOI: 10.3390/ijerph192215047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 11/13/2022] [Accepted: 11/13/2022] [Indexed: 06/16/2023]
Abstract
This study aimed to evaluate the effect of three oral hygiene tools, a regular toothbrush, an electronic toothbrush, and mouthwash, on the color stability of three different computer-aided design (CAD) and computer-aided manufactured (CAM) ceramic blocks. Feldspathic ceramic (Vita Triluxe Forte), hybrid resin ceramic (Vita Enamic), and lithium disilicate glass-ceramic (IPS e.max CAD) were used in this study. A CAD/CAM system and 81 (27 of each material) samples of ceramic blocks were used. All samples were immersed in black coffee for 15 days, and the coffee was changed twice per day. Using a spectrophotometer probe, samples on a grey background were scanned, and physical properties like surface hardness and depth were measured using interferometry and a 3D non-contact surface metrology. After 30 days of application of oral hygiene tools, instruments were used to measure various physical, mechanical, and optical properties. Vita Triluxe had the highest average color variation values (ΔE00) after 15 and 30 days of immersion in coffee in both regular and electronic toothbrushes. Moreover, IPS e.max CAD had the least ΔE00 values with no significant differences among the groups. The surface roughness (Ra) of the Vita Enamic ceramic increased when using a regular toothbrush, and the surface height (Rz) for the Vita Enamic ceramic increased when an electronic toothbrush was used. IPS e.max CAD had the greatest modules of elasticity forces, and Vita Triluxe Forte had the lowest when used with a regular toothbrush. The ΔE00 values of the tested materials were minimally increased or decreased after 30 days of cleaning, and all were clinically acceptable. Ra and Rz were the highest for Vita Enamic in comparison to the other groups. The highest percentage in IPS e.max CAD was associated with a type 1 fracture, whereas type 3 was predominantly observed with Vita Enamic, and type 2 in the Vita Triluxe group without significant differences.
Collapse
Affiliation(s)
- Nasser M. Al Ahmari
- Prosthetic Department, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia
| | - Maram A. Alahmari
- Saudi Board Prosthodontic Resident, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia
| | - Mohammed M. Al Moaleem
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia
- Faculty of Dentistry, University of Ibn al-Nafis for Medical Sciences, Sana’a 4337, Yemen
| | | | - Fatimah F. Alqahtani
- Dental Interns, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia
| | - Waad Saeed Mohammed
- Dental Interns, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia
| | - Bandar M. A. Al-Makramani
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia
| | - Vini Mehta
- Department of Public Health Dentistry, Dr. D.Y. Patil Dental College and Hospital, Dr. D.Y. Patil Vidyapeeth, Pune 411018, India
| | - Aida Meto
- Department of Dentistry, Faculty of Dental Sciences, University of Aldent, 1007 Tirana, Albania
- Clinical Microbiology, School of Dentistry, University of Modena and Reggio Emilia, 41125 Modena, Italy
| | - Agron Meto
- Department of Dentistry, Faculty of Dental Sciences, University of Aldent, 1007 Tirana, Albania
| |
Collapse
|
16
|
Liu Y, Fang M, Zhao R, Liu H, Li K, Tian M, Niu L, Xie R, Bai S. Clinical Applications of Polyetheretherketone in Removable Dental Prostheses: Accuracy, Characteristics, and Performance. Polymers (Basel) 2022; 14:polym14214615. [PMID: 36365609 PMCID: PMC9654455 DOI: 10.3390/polym14214615] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/19/2022] [Accepted: 10/25/2022] [Indexed: 11/06/2022] Open
Abstract
The high-performance thermoplastic polyetheretherketone (PEEK) has excellent mechanical properties, biocompatibility, chemical stability, and radiolucency. The present article comprehensively reviews various applications of PEEK in removable dental prostheses, including in removable partial dentures (RPDs) (frameworks and clasps), double-crown RPDs, and obturators. The clinical performance of PEEK in removable dental prostheses is shown to be satisfactory and promising based on the short-term clinical evidence and technical complications are scarce. Moreover, the accuracy of RPDs is a vital factor for their long-term success rate. PEEK in removable dental prostheses is fabricated using the conventional lost-wax technique and CAD/CAM milling, which produces a good fit. Furthermore, fused deposition modeling is considered to be one of the most practical additive techniques. PEEK in removable prostheses produced by this technique exhibits good results in terms of the framework fit. However, in light of the paucity of evidence regarding other additive techniques, these manufacturers cannot yet be endorsed. Surface roughness, bacterial retention, color stability, and wear resistance should also be considered when attempting to increase the survival rates of PEEK removable prostheses. In addition, pastes represent an effective method for PEEK polishing to obtain a reduced surface roughness, which facilitates lower bacterial retention. As compared to other composite materials, PEEK is less likely to become discolored or deteriorate due to wear abrasion.
Collapse
Affiliation(s)
- Yuchen Liu
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Ming Fang
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Correspondence: (M.F.); (S.B.)
| | - Ruifeng Zhao
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Hengyan Liu
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Kangjie Li
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Min Tian
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Lina Niu
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Rui Xie
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Shizhu Bai
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Correspondence: (M.F.); (S.B.)
| |
Collapse
|
17
|
Optical Behavior and Surface Analysis of Dental Resin Matrix Ceramics Related to Thermocycling and Finishing. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12094346] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Color preservation of esthetic dental restorative materials in the oral environment represents, besides longevity, a concern, and there is still limited knowledge related to the effect of aging on the optical behavior of resin matrix ceramics. The study analyzed the finishing and thermocycling of resin matrix ceramic material surfaces, in order to assess their consequences on optical properties. Five resin matrix CAD/CAM ceramics, namely a polymer-infiltrated ceramic and four types of nanoparticle-filled resins, were selected for the study, and finished by polishing and glazing. Thermocycling was chosen as the in vitro aging method. Surface microroughness, optical and hardness evaluations were achieved before and after artificial aging. Statistical analyses were performed with IBM SPSS Statistics software at a significance value of p < 0.05. Micro-roughness values increased after thermocycling, but were kept under the clinically accepted values. The optical characteristics of resin matrix ceramics were not significantly modified by thermocycling. Values of the glazed samples became closer to those of the polished ones, after hydrothermal aging, even if the differences were insignificant. Thermocycling significantly decreased the microhardness, mainly for glazed samples. This could be the consequence of glaze removal during thermocycling, which means that glazes provide a surface protection for a limited time.
Collapse
|
18
|
Applications and Clinical Behavior of BioHPP in Prosthetic Dentistry: A Short Review. JOURNAL OF COMPOSITES SCIENCE 2022. [DOI: 10.3390/jcs6030090] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
(1) Background: BioHPP® (Bredent, UK) is a partially crystalline poly ether ether ketone (PEEK) that is strengthened using ceramic. PEEK and its various formulations represent a very interesting alternative, and has been in-depth with its literature in recent years; (2) Methods: A PubMed and Scopus search for the term “BioHPP” yielded 73 results and 42 articles which were included in this short review. Considering the scarce literature on the subject, each article was considered in this review; (3) Results: the articles analyzed are very recent, all published in the last 5 years. Their clinical evaluation of BioHPP® highlights many positive aspects, and few articles have highlighted critical issues in its multiple clinical applications; (4) Conclusions: this material is not only extremely interesting for the future, but possesses characteristics suitable for clinical application today, for endocrowns, small adhesive bridges, temporary prostheses and for immediate loads on implant restorations. The excellent aesthetics and the possibility of simple reprocessing of the restorations made with this material invite its clinical application.
Collapse
|