1
|
Mani SK, Kadolkar R, Prajapati T, Ahuja P, Shajahan M, Lee J, Tolosa M, McWilliams M, Welty C, Frey DD, Srinivasan V, Ujjain SK, Rao G. Microfluidic-electrochemical sensor utilizing statistical modeling for enhanced nitrate detection in surface water towards environmental monitoring. Analyst 2025. [PMID: 40241506 DOI: 10.1039/d5an00092k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/18/2025]
Abstract
The presence of nitrate (NO3-) in surface water and groundwater used for potable supply needs to be closely monitored since in elevated amounts it can adversely affect aquatic life and human health by causing hypoxia and methemoglobinemia. Many of the existing EPA-certified sensors used for environmental monitoring are expensive, bulky, and labor-intensive. To address these concerns, we have successfully developed a low-cost microfluidic electrochemical impedimetric sensor, consisting of a nitrate-binding nickel complex within a polyaniline/carbon nanocomposite (Ni@Pani/C) enabling nitrate monitoring in field samples. Under optimized conditions, our sensor demonstrated a high sensitivity of 2.31 ± 0.09 Ω ppm-1 cm-2 across a wide nitrate concentration range (0.6-10 ppm). It also showed a desirable low detection limit of 0.015 ppm and a swift response time under 20 seconds. It maintained repeatability over a wide temperature range (5-65 °C) and exhibited consistent performance over an extended period (∼1 month). The sensor exhibited high specificity towards nitrate when tested against potential interferences (SO42-, C2H3O2-, HCO3-, NH4+, Cl-) and showed good reproducibility for test water samples collected from various streams in Maryland, U.S.A. A statistical model was used to confirm the sensor's accuracy, which yielded a maximum standard deviation of ±0.6 ppm (absolute value). Our sensor was also benchmarked against a commercial SUNA device resulting in comparable performance.
Collapse
Affiliation(s)
- Sai Kiran Mani
- Center for Advanced Sensor Technology, Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.
| | - Revati Kadolkar
- Center for Advanced Sensor Technology, Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.
- Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA
| | - Tithi Prajapati
- Center for Advanced Sensor Technology, Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.
- Department of Biological Sciences, University of Maryland Baltimore County, Baltimore, MD, 21250, USA
| | - Preety Ahuja
- Center for Advanced Sensor Technology, Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.
| | - Mesha Shajahan
- Center for Advanced Sensor Technology, Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.
- Department of Biological Sciences, University of Maryland Baltimore County, Baltimore, MD, 21250, USA
| | - JungHun Lee
- Center for Advanced Sensor Technology, Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.
- Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA
| | - Michael Tolosa
- Center for Advanced Sensor Technology, Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.
| | - Mary McWilliams
- Center for Urban Environmental Research and Education, University of Maryland Baltimore County, Baltimore, MD 21250, USA
| | - Claire Welty
- Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA
- Center for Urban Environmental Research and Education, University of Maryland Baltimore County, Baltimore, MD 21250, USA
| | - Douglas D Frey
- Center for Advanced Sensor Technology, Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.
- Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA
| | - Venkatesh Srinivasan
- Center for Advanced Sensor Technology, Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.
| | - Sanjeev Kumar Ujjain
- Center for Advanced Sensor Technology, Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.
| | - Govind Rao
- Center for Advanced Sensor Technology, Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA.
- Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD 21250, USA
| |
Collapse
|
2
|
Sarvestani PS, Majdinasab M, Golmakani MT, Shaghaghian S, Eskandari MH. Development of a simple and rapid dipstick paper-based test strip for colorimetric determination of nitrate and nitrite in water and foodstuffs. Food Chem 2024; 461:140856. [PMID: 39173253 DOI: 10.1016/j.foodchem.2024.140856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2024] [Revised: 08/08/2024] [Accepted: 08/11/2024] [Indexed: 08/24/2024]
Abstract
A rapid user-friendly paper-based test strip using zinc microparticles in conjugation with Griess reagent was developed for nitrite and nitrate detection. Test strips were fabricated using a simple and fast method of step-by-step immersion into reagents so that each strip contained a single detection pad for nitrite detection and another separate pad for nitrate detection. To reduce nitrate to nitrite, zinc microparticles suspended in ethanolic solution of polyvinylpyrrolidone (PVP) were uniformly immobilized on the paper strips that were previously impregnated in the Griess reagent and dried. The Griess reagent components were optimized to reach the highest color intensity. The optimized test strip was able to determine both nitrite and nitrate with respective detection limits of 0.43 and 9.43 mg/kg and a detection time of 60 s. The performance of the new test strips was evaluated for the simultaneous colorimetric detection of nitrite and nitrate in water and different food samples.
Collapse
Affiliation(s)
- Parisa Shafeie Sarvestani
- Department of Food Science and Technology, School of Agriculture, Shiraz University, Shiraz 71441-65186, Iran
| | - Marjan Majdinasab
- Department of Food Science and Technology, School of Agriculture, Shiraz University, Shiraz 71441-65186, Iran.
| | - Mohammad-Taghi Golmakani
- Department of Food Science and Technology, School of Agriculture, Shiraz University, Shiraz 71441-65186, Iran
| | - Samaneh Shaghaghian
- Department of Food Science and Technology, School of Agriculture, Shiraz University, Shiraz 71441-65186, Iran
| | - Mohammad-Hadi Eskandari
- Department of Food Science and Technology, School of Agriculture, Shiraz University, Shiraz 71441-65186, Iran
| |
Collapse
|
3
|
Sousa LR, Moreira NS, Guinati BGS, Coltro WKT, Cortón E, Figueredo F. Improved sensitivity in paper-based microfluidic analytical devices using a pH-responsive valve for nitrate analysis. Talanta 2024; 277:126361. [PMID: 38878509 DOI: 10.1016/j.talanta.2024.126361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 05/31/2024] [Accepted: 06/03/2024] [Indexed: 07/19/2024]
Abstract
This paper presents an innovative application of chitosan material to be used as pH-responsive valves for the precise control of lateral flow in microfluidic paper-based analytical devices (μPADs). The fabrication of μPADs involved wax printing, while pH-responsive valves were created using a solution of chitosan in acetic acid. The valve-forming solution was applied, and ready when dry; by exposure to acidic solutions, the valve opens. Remarkably, the valves exhibited excellent compatibility with alkaline, neutral, and acidic solutions with a pH higher than 4. The valve opening process had no impact on the flow rate and colorimetric analysis. The potential of chitosan valves used for flow control was demonstrated for μPADs employed for nitrate determination. Valves were used to increase the conversion time of nitrate to nitrite, which was further analyzed using the Griess reaction. The μPAD showed a linear response in the concentration range of 10-100 μmol L-1, with a detection limit of 5.4 μmol L-1. As a proof of concept, the assay was successfully applied to detect nitrate levels in water samples from artificial lakes of recreational parks. For analyses that require controlled kinetics and involve multiple sequential steps, the use of chitosan pH-responsive valves in μPADs is extremely valuable. This breakthrough holds great potential for the development of simple and high-impact microfluidic platforms that can cater to a wide range of analytical chemistry applications.
Collapse
Affiliation(s)
- Lucas R Sousa
- Departamento de Química Biológica e IQUIBICEN -CONICET, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires (UBA), CABA, Argentina; Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil
| | - Nikaele S Moreira
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil
| | - Bárbara G S Guinati
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil
| | - Wendell K T Coltro
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica, 13084-971, Campinas, SP, Brazil
| | - Eduardo Cortón
- Departamento de Química Biológica e IQUIBICEN -CONICET, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires (UBA), CABA, Argentina
| | - Federico Figueredo
- Departamento de Química Biológica e IQUIBICEN -CONICET, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires (UBA), CABA, Argentina.
| |
Collapse
|
4
|
Kumar S, Kaushal JB, Lee HP. Sustainable Sensing with Paper Microfluidics: Applications in Health, Environment, and Food Safety. BIOSENSORS 2024; 14:300. [PMID: 38920604 PMCID: PMC11202065 DOI: 10.3390/bios14060300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 06/04/2024] [Accepted: 06/05/2024] [Indexed: 06/27/2024]
Abstract
This manuscript offers a concise overview of paper microfluidics, emphasizing its sustainable sensing applications in healthcare, environmental monitoring, and food safety. Researchers have developed innovative sensing platforms for detecting pathogens, pollutants, and contaminants by leveraging the paper's unique properties, such as biodegradability and affordability. These portable, low-cost sensors facilitate rapid diagnostics and on-site analysis, making them invaluable tools for resource-limited settings. This review discusses the fabrication techniques, principles, and applications of paper microfluidics, showcasing its potential to address pressing challenges and enhance human health and environmental sustainability.
Collapse
Affiliation(s)
- Sanjay Kumar
- Durham School of Architectural Engineering and Construction, University of Nebraska-Lincoln, Scott Campus, Omaha, NE 68182-0816, USA
| | - Jyoti Bala Kaushal
- Department of Biochemistry and Molecular Biology, University of Nebraska Medical Center, Omaha, NE 68198, USA
| | - Heow Pueh Lee
- Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117575, Singapore;
| |
Collapse
|
5
|
Uhlikova N, Almeida MIGS, McKelvie ID, Kolev SD. Microfluidic paper-based analytical device for the speciation of inorganic nitrogen species. Talanta 2024; 271:125671. [PMID: 38306810 DOI: 10.1016/j.talanta.2024.125671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Revised: 01/08/2024] [Accepted: 01/13/2024] [Indexed: 02/04/2024]
Abstract
A microfluidic paper-based analytical device (μPAD) utilizing gas-diffusion separation and solid-phase reduction was developed for the first time for the determination of both ammonium and nitrate, which are the dominant inorganic nitrogen species in environmental waters. The device consists of 3 filter paper layers accommodating the sample, reagent and detection zones. The reagent zone is separated from the detection zone by a semipermeable hydrophobic membrane and acts as a solid-phase reactor where nitrate is reduced to ammonia by Devarda's alloy microparticles, integrated into a μPAD for the first time. The detection zone incorporates the acid-base indicators bromothymol blue (BTB) or nitrazine yellow (NY) and changes colour in two steps. Initially the colour change is caused by ammonia generated by the reaction of ammonium and sodium hydroxide in the sample zone. This colour change is followed by a subsequent colour change as a result of the ammonia produced by the reduction of nitrate by the Devarda's alloy microparticles. The corresponding reflectance value changes are used for the quantification of the two inorganic nitrogen species in the ranges 6.5-100.0 or 2.1-15.0 mg N L-1 for ammonium and 18.2-100.0 or 4.2-15.0 mg N L-1 for nitrate when BTB or NY are used, respectively. Under optimal conditions the limits of quantification of ammonium and nitrate in the case of BTB were determined as 6.5 and 18.2 mg N L-1, respectively, while the corresponding values in the case of NY were found to be 2.1 and 4.2 mg N L-1. The newly developed μPAD was stable for 62 days when stored in a freezer and 1 day at ambient temperature. It was validated with a certified reference material and successfully applied to the determination of ammonium and nitrate in spiked environmental water samples and soil extracts.
Collapse
Affiliation(s)
- Natalie Uhlikova
- School of Chemistry, The University of Melbourne, Victoria 3010, Australia
| | - M Inês G S Almeida
- School of Chemistry, The University of Melbourne, Victoria 3010, Australia
| | - Ian D McKelvie
- School of Chemistry, The University of Melbourne, Victoria 3010, Australia
| | - Spas D Kolev
- School of Chemistry, The University of Melbourne, Victoria 3010, Australia; Department of Chemical Engineering, The University of Melbourne, Victoria 3010, Australia; Sofia University "St. Kl. Ohridski", Faculty of Chemistry and Pharmacy, 1 James Bourchier Blvd., Sofia 1164, Bulgaria.
| |
Collapse
|
6
|
Xu X, Nilghaz A, Wan X, Liu S, Xue M, Guo W, Tian J. A novel premixing strategy for highly sensitive detection of nitrite on paper-based analytical devices. Anal Chim Acta 2024; 1299:342417. [PMID: 38499414 DOI: 10.1016/j.aca.2024.342417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Revised: 02/04/2024] [Accepted: 02/25/2024] [Indexed: 03/20/2024]
Abstract
BACKGROUND Nitrite has been involved in many food processing techniques and its excessive consumption is closely related to the development of different diseases. Therefore, highly sensitive detection of nitrite is significant to ensure food safety. RESULT This study presents a simple and novel strategy for the highly sensitive detection of nitrite in food using paper-based analytical devices (PADs). In this proposed strategy, the nitrite present in the sample undergoes efficient diazotization when initially mixed with sulfanilamide solution before reacting with N-(1-naphthyl) ethylenediamine dihydrochloride (NED) coated on the detection region of the PAD, leading to the maximum production of colored azo compounds. Specifically, within the concentration range of 0.1-20 mg/L, the LOD and LOQ for the nitrite assay using the premixing strategy are determined as 0.053 mg/L and 0.18 mg/L, respectively which significantly surpass the corresponding values of 0.18 mg/L (LOD) and 0.61 mg/L (LOQ) achieved with the regular Griess reagent analysis. SIGNIFICANCE The study highlights the critical importance of the premixing strategy in nitrite detection. Under optimized conditions, the strategy demonstrates an excellent limit of detection (LOD) and limit of quantification (LOQ) for nitrite detection in eight different meat samples. In addition to its high precision, the strategy is applicable in the field of nitrite analysis. This strategy could facilitate rapid and cost-effective nitrite analysis in real food samples, ensuring food safety and quality analysis.
Collapse
Affiliation(s)
- Xiaohu Xu
- State Key Laboratory of Pulp and Paper Engineering, School of Light Industry and Engineering, South China University of Technology, Guangzhou, 510641, China
| | - Azadeh Nilghaz
- Institute for Frontier Materials, Deakin University, Waurn Ponds, Victoria, 3216, Australia; Drug Delivery, Disposition, and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia
| | - Xiaofang Wan
- State Key Laboratory of Pulp and Paper Engineering, School of Light Industry and Engineering, South China University of Technology, Guangzhou, 510641, China
| | - Shan Liu
- School of Medicine, South China University of Technology, Guangzhou, 510006, China; Guangdong Provincial Key Laboratory of Plant Resources Biorefinery, Guangzhou, 510006, China.
| | - Meigui Xue
- Dongguan Polytechnic, Dongguan, 523808, Guangdong, China
| | - Wan Guo
- Zhejiang Kan New Mat Co Ltd, Lishui, 323300, Zhejiang, China
| | - Junfei Tian
- State Key Laboratory of Pulp and Paper Engineering, School of Light Industry and Engineering, South China University of Technology, Guangzhou, 510641, China; Guangdong Provincial Key Laboratory of Plant Resources Biorefinery, Guangzhou, 510006, China.
| |
Collapse
|
7
|
Khachornsakkul K, Del-Rio-Ruiz R, Creasey H, Widmer G, Sonkusale SR. Gold Nanomaterial-Based Microfluidic Paper Analytical Device for Simultaneous Quantification of Gram-Negative Bacteria and Nitrite Ions in Water Samples. ACS Sens 2023; 8:4364-4373. [PMID: 37997658 DOI: 10.1021/acssensors.3c01769] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2023]
Abstract
This study presents a rapid microfluidic paper-based analytical device (μPAD) capable of simultaneously monitoring Gram-negative bacteria and nitrite ions (NO2-) for water quality monitoring. We utilize gold nanoparticles (AuNPs) functionalized with polymyxin molecules (AuNPs@polymyxin) to cause color change due to aggregation for the detection of Gram-negative bacteria, and antiaggregation in the presence of o-phenylenediamine (OPD) for NO2- detection. In this study, Escherichia coli (E. coli) serves as the model of a Gram-negative bacterium. Using the developed μPADs, the color changes resulting from aggregation and antiaggregation reactions are measured using a smartphone application. The linear detection ranges from 5.0 × 102 to 5.0 × 105 CFU/mL (R2 = 0.9961) for E. coli and 0.20 to 2.0 μmol/L (R2 = 0.995) for NO2-. The detection limits were determined as 2.0 × 102 CFU/mL for E. coli and 0.18 μmol/L for NO2-. Notably, the newly developed assay exhibited high selectivity with no interference from Gram-positive bacteria. Additionally, we obtained acceptable recovery for monitoring E. coli and NO2- in drinking water samples with no significant difference between our method and a commercial assay by t test validation. The sensor was also employed for assessing the quality of the pond and environmental water source. Notably, this approach can also be applied to human urine samples with satisfactory accuracy. Furthermore, the assay's stability is extended due to its reliance on AuNPs rather than reagents like antibodies and enzymes, reducing costs and ensuring long-term viability. Our cost-effective μPADs therefore provide a real-time analysis of both contaminants, making them suitable for assessing water quality in resource-limited settings.
Collapse
Affiliation(s)
- Kawin Khachornsakkul
- Department of Electrical and Computer Engineering, Tufts University, Medford, Massachusetts 02155, United States
- Nano Lab, Tufts University, Medford, Massachusetts 02155, United States
| | - Ruben Del-Rio-Ruiz
- Department of Electrical and Computer Engineering, Tufts University, Medford, Massachusetts 02155, United States
- Nano Lab, Tufts University, Medford, Massachusetts 02155, United States
| | - Hannah Creasey
- Department of Infectious Diseases and Global Health, Cummings School of Veterinary Medicine, Tufts University, North Grafton, Massachusetts 01536, United States
| | - Giovanni Widmer
- Department of Infectious Diseases and Global Health, Cummings School of Veterinary Medicine, Tufts University, North Grafton, Massachusetts 01536, United States
| | - Sameer R Sonkusale
- Department of Electrical and Computer Engineering, Tufts University, Medford, Massachusetts 02155, United States
- Nano Lab, Tufts University, Medford, Massachusetts 02155, United States
| |
Collapse
|
8
|
Macleod Briongos I, Call ZD, Henry CS, Bark DL. Maximizing flow rate in single paper layer, rapid flow microfluidic paper-based analytical devices. MICROFLUIDICS AND NANOFLUIDICS 2023; 27:70. [PMID: 37719231 PMCID: PMC10499984 DOI: 10.1007/s10404-023-02679-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Accepted: 08/26/2023] [Indexed: 09/19/2023]
Abstract
Small, single-layer microfluidic paper-based analytical devices (µPADs) offer potential for a range of point-of-care applications; however, they have been limited to low flow rates. Here, we investigate the role of laser cutting paper channels in maximizing flow rate in small profile devices with limited fluid volumes. We demonstrate that branching, laser-cut grooves can provide a 59.23-73.98% improvement in flow rate over a single cut, and a 435% increase over paper alone. These design considerations can be applied to more complex microfluidic devices with the aim of increasing the flow rate, and could be used in stand-alone channels for self-pumping. Supplementary Information The online version contains supplementary material available at 10.1007/s10404-023-02679-8.
Collapse
Affiliation(s)
- Iain Macleod Briongos
- School of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523 USA
| | - Zachary D. Call
- Department of Chemistry, Colorado State University, Fort Collins, CO 80523 USA
| | - Charles S. Henry
- Department of Chemistry, Colorado State University, Fort Collins, CO 80523 USA
| | - David L. Bark
- School of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523 USA
- Division of Hematology and Oncology, Department of Pediatrics, Washington University in St. Louis, St. Louis, MO 63108 USA
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, USA
| |
Collapse
|
9
|
Scarsi A, Pedone D, Pompa PP. A multi-line platinum nanozyme-based lateral flow device for the colorimetric evaluation of total antioxidant capacity in different matrices. NANOSCALE ADVANCES 2023; 5:2167-2174. [PMID: 37056622 PMCID: PMC10089119 DOI: 10.1039/d2na00931e] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 02/06/2023] [Indexed: 06/19/2023]
Abstract
The evaluation of Total Antioxidant Capacity (TAC), namely the complete pattern of antioxidant species in a complex medium, is of major interest in many fields ranging from health monitoring to quality control in the food industry. In this framework, point-of-care (POC) testing technologies are a promising diagnostic solution for rapid on-site analyses, unlike laboratory based-assays, which are often limited by centralized analyses, time-consuming and costly procedures, and invasiveness in the case of health diagnostics. In this work, we developed a POC methodology that evaluates TAC in different matrices, exploiting the peroxidase-like properties of 5 nm platinum nanoparticles (PtNPs), combined with a colorimetric paper-based device. Notably, we designed and optimized a multi-line PtNPs-based Lateral Flow Assay (LFA), which relies on three sequential test lines with increasing concentrations of platinum nanozymes, to get a non-invasive, accurate, and fast (10 minutes) colorimetric evaluation of the body TAC in saliva samples. Furthermore, we employed the device as a prototype of a quality control tool in the food industry, for the determination of the TAC in fruit juices.
Collapse
Affiliation(s)
- Anna Scarsi
- Nanobiointeractions & Nanodiagnostics, Istituto Italiano di Tecnologia (IIT) Via Morego 30 16163-Genova Italy
- Department of Chemistry and Industrial Chemistry, University of Genova Via Dodecaneso 31 16146-Genova Italy
| | - Deborah Pedone
- Nanobiointeractions & Nanodiagnostics, Istituto Italiano di Tecnologia (IIT) Via Morego 30 16163-Genova Italy
| | - Pier Paolo Pompa
- Nanobiointeractions & Nanodiagnostics, Istituto Italiano di Tecnologia (IIT) Via Morego 30 16163-Genova Italy
| |
Collapse
|
10
|
Ortiz-Gómez I, Rivadeneyra A, Salmerón JF, de Orbe-Payá I, Morales DP, Capitán-Vallvey LF, Salinas-Castillo A. Near-Field Communication Tag for Colorimetric Glutathione Determination with a Paper-Based Microfluidic Device. BIOSENSORS 2023; 13:267. [PMID: 36832033 PMCID: PMC9954394 DOI: 10.3390/bios13020267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 02/09/2023] [Accepted: 02/11/2023] [Indexed: 06/18/2023]
Abstract
Here, we propose a microfluidic paper-based analytical device (µPAD) implemented with a near-field communication (NFC) tag as a portable, simple and fast colorimetric method for glutathione (GSH) determination. The proposed method was based on the fact that Ag+ could oxidize 3,3',5,5'-tetramethylbenzidine (TMB) into oxidized blue TMB. Thus, the presence of GSH could cause the reduction of oxidized TMB, which resulted in a blue color fading. Based on this finding, we developed a method for the colorimetric determination of GSH using a smartphone. A µPAD implemented with the NFC tag allowed the harvesting of energy from a smartphone to activate the LED that allows the capture of a photograph of the µPAD by the smartphone. The integration between electronic interfaces into the hardware of digital image capture served as a means for quantitation. Importantly, this new method shows a low detection limit of 1.0 µM. Therefore, the most important features of this non-enzymatic method are high sensitivity and a simple, fast, portable and low-cost determination of GSH in just 20 min using a colorimetric signal.
Collapse
Affiliation(s)
- Inmaculada Ortiz-Gómez
- ECsens, Department of Analytical Chemistry, Faculty of Sciences, University of Granada, 18071 Granada, Spain
- Unit of Excellence in Chemistry Applied to Biomedicine and the Environment, Faculty of Science, University of Granada, 18071 Granada, Spain
| | - Almudena Rivadeneyra
- Unit of Excellence in Chemistry Applied to Biomedicine and the Environment, Faculty of Science, University of Granada, 18071 Granada, Spain
- Electronic Devices Research Group, Department of Electronics and Computer Technology, Faculty of Sciences, University of Granada, 18071 Granada, Spain
| | - José F. Salmerón
- Unit of Excellence in Chemistry Applied to Biomedicine and the Environment, Faculty of Science, University of Granada, 18071 Granada, Spain
- Electronic Devices Research Group, Department of Electronics and Computer Technology, Faculty of Sciences, University of Granada, 18071 Granada, Spain
| | - Ignacio de Orbe-Payá
- ECsens, Department of Analytical Chemistry, Faculty of Sciences, University of Granada, 18071 Granada, Spain
- Unit of Excellence in Chemistry Applied to Biomedicine and the Environment, Faculty of Science, University of Granada, 18071 Granada, Spain
| | - Diego P. Morales
- Unit of Excellence in Chemistry Applied to Biomedicine and the Environment, Faculty of Science, University of Granada, 18071 Granada, Spain
- Electronic Devices Research Group, Department of Electronics and Computer Technology, Faculty of Sciences, University of Granada, 18071 Granada, Spain
| | - Luis Fermín Capitán-Vallvey
- ECsens, Department of Analytical Chemistry, Faculty of Sciences, University of Granada, 18071 Granada, Spain
- Unit of Excellence in Chemistry Applied to Biomedicine and the Environment, Faculty of Science, University of Granada, 18071 Granada, Spain
| | - Alfonso Salinas-Castillo
- ECsens, Department of Analytical Chemistry, Faculty of Sciences, University of Granada, 18071 Granada, Spain
- Unit of Excellence in Chemistry Applied to Biomedicine and the Environment, Faculty of Science, University of Granada, 18071 Granada, Spain
| |
Collapse
|
11
|
Li Z, Liu H, Wang D, Zhang M, Yang Y, Ren TL. Recent advances in microfluidic sensors for nutrients detection in water. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2022.116790] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
12
|
Khosravi H, Mehrdel P, Martínez JAL, Casals-Terré J. Porous Cellulose Substrate Study to Improve the Performance of Diffusion-Based Ionic Strength Sensors. MEMBRANES 2022; 12:1074. [PMID: 36363629 PMCID: PMC9699251 DOI: 10.3390/membranes12111074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Revised: 10/26/2022] [Accepted: 10/27/2022] [Indexed: 06/16/2023]
Abstract
Microfluidic paper-based analytical devices (µPADs) are leading the field of low-cost, quantitative in-situ assays. However, understanding the flow behavior in cellulose-based membranes to achieve an accurate and rapid response has remained a challenge. Previous studies focused on commercial filter papers, and one of their problems was the time required to perform the test. This work studies the effect of different cellulose substrates on diffusion-based sensor performance. A diffusion-based sensor was laser cut on different cellulose fibers (Whatman and lab-made Sisal papers) with different structure characteristics, such as basis weight, density, pore size, fiber diameter, and length. Better sensitivity and faster response are found in papers with bigger pore sizes and lower basis weights. The designed sensor has been successfully used to quantify the ionic concentration of commercial wines with a 13.6 mM limit of detection in 30 s. The developed µPAD can be used in quantitative assays for agri-food applications without the need for any external equipment or trained personnel.
Collapse
Affiliation(s)
- Hamid Khosravi
- Mechanical Engineering Department—MicroTech Lab., Universitat Politècnica de Catalunya (UPC), C/Colom 7-11, 08222 Terrassa, Barcelona, Spain
| | - Pouya Mehrdel
- Mechanical Engineering Department—MicroTech Lab., Universitat Politècnica de Catalunya (UPC), C/Colom 7-11, 08222 Terrassa, Barcelona, Spain
| | - Joan Antoni López Martínez
- Department of Mining, Industrial and ICT Engineering (EMIT), Universitat Politècnica de Catalunya (UPC), AV. Bases de Manresa 61-73, 08240 Manresa, Barcelona, Spain
| | - Jasmina Casals-Terré
- Mechanical Engineering Department—MicroTech Lab., Universitat Politècnica de Catalunya (UPC), C/Colom 7-11, 08222 Terrassa, Barcelona, Spain
| |
Collapse
|
13
|
Pomili T, Gatto F, Pompa PP. A Lateral Flow Device for Point-of-Care Detection of Doxorubicin. BIOSENSORS 2022; 12:896. [PMID: 36291033 PMCID: PMC9599782 DOI: 10.3390/bios12100896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 10/18/2022] [Accepted: 10/18/2022] [Indexed: 06/16/2023]
Abstract
A simple, rapid, and sensitive point-of-care (POC) device for the on-site detection of doxorubicin was developed. The proposed method relies on the naked-eye detection of the intrinsic fluorescence of the drug in a lateral flow device (LFD) configuration, exploiting the biological recognition of DNA probes and avoiding the use of expensive antibodies and sophisticated instrumentations. The POC assay does not require any pre-treatment or purification step and provides an immediate visual readout, achieving a limit of detection as low as ca. 1 ng doxorubicin, outperforming several laboratory-based instrumental techniques. The POC method was proven useful for the detection of trace amounts of the drug both in the case of water solutions (to simulate surface contaminations) and in urine samples, opening promising perspectives for routine monitoring of doxorubicin, with potential benefit to healthcare workers and personalized chemotherapies.
Collapse
Affiliation(s)
- Tania Pomili
- Nanobiointeractions & Nanodiagnostics, Istituto Italiano di Tecnologia (IIT), Via Morego, 30-16163 Genova, Italy
- Department of Chemistry and Industrial Chemistry, University of Genova, Via Dodecaneso, 31-16146 Genova, Italy
| | - Francesca Gatto
- Nanobiointeractions & Nanodiagnostics, Istituto Italiano di Tecnologia (IIT), Via Morego, 30-16163 Genova, Italy
| | - Pier Paolo Pompa
- Nanobiointeractions & Nanodiagnostics, Istituto Italiano di Tecnologia (IIT), Via Morego, 30-16163 Genova, Italy
| |
Collapse
|
14
|
Wang J, Yang L, Wang H, Wang L. Application of Microfluidic Chips in the Detection of Airborne Microorganisms. MICROMACHINES 2022; 13:1576. [PMID: 36295928 PMCID: PMC9611547 DOI: 10.3390/mi13101576] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 09/14/2022] [Accepted: 09/17/2022] [Indexed: 06/16/2023]
Abstract
The spread of microorganisms in the air, especially pathogenic microorganisms, seriously affects people's normal life. Therefore, the analysis and detection of airborne microorganisms is of great importance in environmental detection, disease prevention and biosafety. As an emerging technology with the advantages of integration, miniaturization and high efficiency, microfluidic chips are widely used in the detection of microorganisms in the environment, bringing development vitality to the detection of airborne microorganisms, and they have become a research highlight in the prevention and control of infectious diseases. Microfluidic chips can be used for the detection and analysis of bacteria, viruses and fungi in the air, mainly for the detection of Escherichia coli, Staphylococcus aureus, H1N1 virus, SARS-CoV-2 virus, Aspergillus niger, etc. The high sensitivity has great potential in practical detection. Here, we summarize the advances in the collection and detection of airborne microorganisms by microfluidic chips. The challenges and trends for the detection of airborne microorganisms by microfluidic chips was also discussed. These will support the role of microfluidic chips in the prevention and control of air pollution and major outbreaks.
Collapse
Affiliation(s)
- Jinpei Wang
- College of Medicine, Xi’an International University, Xi’an 710077, China
- Engineering Research Center of Personalized Anti-Aging Health Product Development and Transformation, Universities of Shaanxi Province, Xi’an 710077, China
- Applied Research Center for Life Science, Xi’an International University, Xi’an 710077, China
| | - Lixia Yang
- College of Medicine, Xi’an International University, Xi’an 710077, China
- Engineering Research Center of Personalized Anti-Aging Health Product Development and Transformation, Universities of Shaanxi Province, Xi’an 710077, China
- Applied Research Center for Life Science, Xi’an International University, Xi’an 710077, China
| | - Hanghui Wang
- College of Medicine, Xi’an International University, Xi’an 710077, China
- Xi’an International Medical Center Hospital, Xi’an 710100, China
| | - Lin Wang
- College of Medicine, Xi’an International University, Xi’an 710077, China
- Engineering Research Center of Personalized Anti-Aging Health Product Development and Transformation, Universities of Shaanxi Province, Xi’an 710077, China
- Applied Research Center for Life Science, Xi’an International University, Xi’an 710077, China
| |
Collapse
|
15
|
Heidari-Bafroui H, Kumar A, Charbaji A, Smith W, Rahmani N, Anagnostopoulos C, Faghri M. A Parametric Study on a Paper-Based Bi-Material Cantilever Valve. MICROMACHINES 2022; 13:mi13091502. [PMID: 36144125 PMCID: PMC9506191 DOI: 10.3390/mi13091502] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Revised: 09/05/2022] [Accepted: 09/08/2022] [Indexed: 06/01/2023]
Abstract
The novel paper-based Bi-Material Cantilever (B-MaC) valve allows the autonomous loading and control of multiple fluid reagents which contributes to the accurate operation of paper-based microfluidic devices utilized for biological and chemical sensing applications. In this paper, an extensive parametric study is presented to evaluate the effects of key geometric parameters of the valve, such as paper direction, cantilever width, paper type, tape type, and sample volume, in addition to the effects of relative humidity and temperature on the functionality of the B-MaC and to provide a better understanding of the rate of fluid flow and resulting deflection of the cantilever. Machine direction, cantilever width, paper type, and tape type were found to be important parameters that affect the B-MAC's activation time. It was also observed that the rate of fluid imbibition in the B-MaC is considerably affected by change in humidity for high (55 °C) and low (25 °C) temperatures, while humidity levels have no significant effect during imbibition in the B-MaC at an ambient temperature of 45 °C. It was also found that a minimum distance of 4 mm is required between the B-MaC and the stationary component to prevent accidental activation of the B-MaC prior to sample insertion when relative humidity is higher than 90% and temperature is lower than 35 °C. The rate of fluid imbibition that determines the wetted length of the B-MaC and the final deflection of the cantilever are critical in designing and fabricating point-of-care microfluidic paper-based devices. The B-MaC valve can be utilized in a fluidic circuit to sequentially load several reagents, in addition to the sample to the detection area.
Collapse
|
16
|
Pham ATT, Tohl D, Hu Q, Li J, Reynolds KJ, Tang Y. Portable Colorimetric Device with Commercial Microplates for Quantitative Detection of Urine Biomarkers: Design, Development, and Clinical Evaluation. BIOSENSORS 2022; 12:723. [PMID: 36140108 PMCID: PMC9496577 DOI: 10.3390/bios12090723] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Revised: 08/29/2022] [Accepted: 08/31/2022] [Indexed: 12/04/2022]
Abstract
Urine biomarkers are important in monitoring diseases related to human kidney function. The current processes for measuring biomarker levels in urine samples require patients to regularly visit clinical facilities, which is inconvenient and sometimes impossible for patients in rural areas. Therefore, portable analysis devices for the measurement of urine biomarkers are urgently requested. In this study, a portable platform using colorimetry, a common and simple-to-operate chemical analysis technique, was developed to measure urine biomarkers. The device, using commercial test kits as recognising reagents and a 96-well microplate as a solution container, provides quantitative measures of biomarker concentration. Moreover, the proposed device introduces a calibration method to minimise the dependence of regular maintenance. The device's performance was evaluated with urine from 73 renal patients and its results matched with clinical results well. The device has the potential for measuring urine creatinine, in addition to performing a variety of commercial assays for biomarker detection in human body fluids in general.
Collapse
Affiliation(s)
- Anh Tran Tam Pham
- Australia-China Joint Research Centre for Personal Health Technologies, Medical Device Research Institute, Flinders University, Tonsley, SA 5042, Australia
| | - Damian Tohl
- Australia-China Joint Research Centre for Personal Health Technologies, Medical Device Research Institute, Flinders University, Tonsley, SA 5042, Australia
| | - Qi Hu
- Australia-China Joint Research Centre for Personal Health Technologies, Medical Device Research Institute, Flinders University, Tonsley, SA 5042, Australia
| | - Jordan Li
- Department of Renal Medicine, Flinders Medical Centre, College of Medicine and Public Health, Flinders University, Bedford Park, SA 5042, Australia
| | - Karen J. Reynolds
- Australia-China Joint Research Centre for Personal Health Technologies, Medical Device Research Institute, Flinders University, Tonsley, SA 5042, Australia
| | - Youhong Tang
- Australia-China Joint Research Centre for Personal Health Technologies, Medical Device Research Institute, Flinders University, Tonsley, SA 5042, Australia
| |
Collapse
|
17
|
Yakimov AS, Denisov IA, Bukatin AS, Lukyanenko KA, Belousov KI, Kukhtevich IV, Esimbekova EN, Evstrapov AA, Belobrov PI. Droplet Microfluidic Device for Chemoenzymatic Sensing. MICROMACHINES 2022; 13:1146. [PMID: 35888963 PMCID: PMC9325247 DOI: 10.3390/mi13071146] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 07/15/2022] [Accepted: 07/18/2022] [Indexed: 12/14/2022]
Abstract
The rapid detection of pollutants in water can be performed with enzymatic probes, the catalytic light-emitting activity of which decreases in the presence of many types of pollutants. Herein, we present a microfluidic system for continuous chemoenzymatic biosensing that generates emulsion droplets containing two enzymes of the bacterial bioluminescent system (luciferase and NAD(P)H:FMN-oxidoreductase) with substrates required for the reaction. The developed chip generates "water-in-oil" emulsion droplets with a volume of 0.1 μL and a frequency of up to 12 drops per minute as well as provides the efficient mixing of reagents in droplets and their distancing. The bioluminescent signal from each individual droplet was measured by a photomultiplier tube with a signal-to-noise ratio of up to 3000/1. The intensity of the luminescence depended on the concentration of the copper sulfate with the limit of its detection of 5 μM. It was shown that bioluminescent enzymatic reactions could be carried out in droplet reactors in dispersed streams. The parameters and limitations required for the bioluminescent reaction to proceed were also studied. Hereby, chemoenzymatic sensing capabilities powered by a droplet microfluidics manipulation technique may serve as the basis for early-warning online water pollution systems.
Collapse
Affiliation(s)
- Anton S. Yakimov
- Laboratory of Physical and Chemical Technologies for the Development of Hard-to-Recover Hydrocarbon Reserves, Siberian Federal University, 660041 Krasnoyarsk, Russia;
| | - Ivan A. Denisov
- Laboratory of Physical and Chemical Technologies for the Development of Hard-to-Recover Hydrocarbon Reserves, Siberian Federal University, 660041 Krasnoyarsk, Russia;
- Laboratory of Bioluminescent Biotechnologies, Siberian Federal University, 660041 Krasnoyarsk, Russia;
| | - Anton S. Bukatin
- Laboratory of Renewable Energy Sources, Alferov University, 194021 Saint Petersburg, Russia; (A.S.B.); (K.I.B.)
- Institute for Analytical Instrumentation RAS, 194021 Saint Petersburg, Russia;
| | - Kirill A. Lukyanenko
- Laboratory of Bioluminescent Biotechnologies, Siberian Federal University, 660041 Krasnoyarsk, Russia;
- Laboratory for Biomolecular and Medical Technologies, Prof. V.F. Voino-Yasenetsky Krasnoyarsk State Medical University, 660022 Krasnoyarsk, Russia
- Laboratory for Digital Controlled Drugs and Theranostics, Federal Research Center “Krasnoyarsk Science Center SB RAS”, 660036 Krasnoyarsk, Russia
| | - Kirill I. Belousov
- Laboratory of Renewable Energy Sources, Alferov University, 194021 Saint Petersburg, Russia; (A.S.B.); (K.I.B.)
| | - Igor V. Kukhtevich
- Institute of Silicate Chemistry of RAS, 199034 Saint Petersburg, Russia;
- Institute of Functional Epigenetics, Helmholtz Zentrum München, 85764 Neuherberg, Germany
| | - Elena N. Esimbekova
- Institute of Biophysics SB RAS, 660036 Krasnoyarsk, Russia;
- Department of Biophysics, Siberian Federal University, 660041 Krasnoyarsk, Russia;
| | | | - Peter I. Belobrov
- Department of Biophysics, Siberian Federal University, 660041 Krasnoyarsk, Russia;
| |
Collapse
|
18
|
Altahan MF, Esposito M, Achterberg EP. Improvement of On-Site Sensor for Simultaneous Determination of Phosphate, Silicic Acid, Nitrate plus Nitrite in Seawater. SENSORS (BASEL, SWITZERLAND) 2022; 22:3479. [PMID: 35591168 PMCID: PMC9104159 DOI: 10.3390/s22093479] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 04/27/2022] [Accepted: 04/29/2022] [Indexed: 02/05/2023]
Abstract
Accurate, on-site determinations of macronutrients (phosphate (PO43-), nitrate (NO3-), and silicic acid (H4SiO4)) in seawater in real time are essential to obtain information on their distribution, flux, and role in marine biogeochemical cycles. The development of robust sensors for long-term on-site analysis of macronutrients in seawater is a great challenge. Here, we present improvements of a commercial automated sensor for nutrients (including PO43-, H4SiO4, and NO2- plus NO3-), suitable for a variety of aquatic environments. The sensor uses the phosphomolybdate blue method for PO43-, the silicomolybdate blue method for H4SiO4 and the Griess reagent method for NO2-, modified with vanadium chloride as reducing agent for the determination of NO3-. Here, we report the optimization of analytical conditions, including reaction time for PO43- analysis, complexation time for H4SiO4 analysis, and analyte to reagent ratio for NO3- analysis. The instrument showed wide linear ranges, from 0.2 to 100 μM PO43-, between 0.2 and 100 μM H4SiO4, from 0.5 to 100 μM NO3-, and between 0.4 and 100 μM NO2-, with detection limits of 0.18 μM, 0.15 μM, 0.45 μM, and 0.35 μM for PO43-, H4SiO4, NO3-, and NO2-, respectively. The analyzer showed good precision with a relative standard deviation of 8.9% for PO43-, 4.8% for H4SiO4, and 7.4% for NO2- plus NO3- during routine analysis of certified reference materials (KANSO, Japan). The analyzer performed well in the field during a 46-day deployment on a pontoon in the Kiel Fjord (located in the southwestern Baltic Sea), with a water supply from a depth of 1 m. The system successfully collected 443, 440, and 409 on-site data points for PO43-, Σ(NO3- + NO2-), and H4SiO4, respectively. Time series data agreed well with data obtained from the analysis of discretely collected samples using standard reference laboratory procedures and showed clear correlations with key hydrographic parameters throughout the deployment period.
Collapse
Affiliation(s)
- Mahmoud Fatehy Altahan
- GEOMAR Helmholtz Centre for Ocean Research Kiel, 24148 Kiel, Germany;
- Central Laboratory for Environmental Quality Monitoring, National Water Research Center, El-Qanater El-Khairia 13621, Egypt
| | - Mario Esposito
- GEOMAR Helmholtz Centre for Ocean Research Kiel, 24148 Kiel, Germany;
| | | |
Collapse
|
19
|
In Situ Detection of Hydrogen Sulfide in 3D-Cultured, Live Prostate Cancer Cells Using a Paper-Integrated Analytical Device. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10010027] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
In this study, a paper-integrated analytical device that combined a paper-based colorimetric assay with a paper-based cell culture platform was developed for the in situ detection of hydrogen sulfide (H2S) in three-dimensional (3D)-cultured, live prostate cancer cells. Two kinds of paper substrates were fabricated using a simple wax-printing methodology to form the cell culture and detection zones, respectively. LNCaP cells were seeded directly on the paper substrate and grown in the paper-integrated analytical device. The cell viability and H2S production of LNCaP cells were assessed using a simple water-soluble tetrazolium salt colorimetric assay and H2S-sensing paper, respectively. The H2S-sensing paper showed good sensitivity (sensitivity: 6.12 blue channel intensity/μM H2S, R2 = 0.994) and a limit of quantification of 1.08 μM. As a result, we successfully measured changes in endogenous H2S production in 3D-cultured, live LNCaP cells within the paper-integrated analytical device while varying the duration of incubation and substrate concentration (L-cysteine). This paper-integrated analytical device can provide a simple and effective method to investigate H2S signaling pathways and drug screening in a 3D culture model.
Collapse
|
20
|
Heidari-Bafroui H, Charbaji A, Anagnostopoulos C, Faghri M. A Colorimetric Dip Strip Assay for Detection of Low Concentrations of Phosphate in Seawater. SENSORS (BASEL, SWITZERLAND) 2021; 21:3125. [PMID: 33946295 PMCID: PMC8125474 DOI: 10.3390/s21093125] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 04/20/2021] [Accepted: 04/22/2021] [Indexed: 12/12/2022]
Abstract
Nutrient pollution remains one of the greatest threats to water quality and imposes numerous public health and ecological concerns. Phosphate, the most common form of phosphorus, is one of the key nutrients necessary for plant growth. However, phosphate concentration in water should be carefully monitored for environmental protection requirements. Hence, an easy-to-use, field-deployable, and reliable device is needed to measure phosphate concentrations in the field. In this study, an inexpensive dip strip is developed for the detection of low concentrations of phosphate in water and seawater. In this device, ascorbic acid/antimony reagent was dried on blotting paper, which served as the detection zone, and was followed by a wet chemistry protocol using the molybdenum method. Ammonium molybdate and sulfuric acid were separately stored in liquid form to significantly improve the lifetime of the device and enhance the reproducibility of its performance. The device was tested with deionized water and Sargasso Sea seawater. The limits of detection and quantification for the optimized device using a desktop scanner were 0.134 ppm and 0.472 ppm for phosphate in water and 0.438 ppm and 1.961 ppm in seawater, respectively. The use of the portable infrared lightbox previously developed at our lab improved the limits of detection and quantification by a factor of three and were 0.156 ppm and 0.769 ppm for the Sargasso Sea seawater. The device's shelf life, storage conditions, and limit of detection are superior to what was previously reported for the paper-based phosphate detection devices.
Collapse
Affiliation(s)
- Hojat Heidari-Bafroui
- Microfluidics Laboratory, Department of Mechanical, Industrial and Systems Engineering, University of Rhode Island, Kingston, RI 02881, USA; (A.C.); (C.A.); (M.F.)
| | | | | | | |
Collapse
|
21
|
An Improved Algorithm for Measuring Nitrate Concentrations in Seawater Based on Deep-Ultraviolet Spectrophotometry: A Case Study of the Aoshan Bay Seawater and Western Pacific Seawater. SENSORS 2021; 21:s21030965. [PMID: 33535502 PMCID: PMC7867073 DOI: 10.3390/s21030965] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 01/27/2021] [Accepted: 01/29/2021] [Indexed: 12/14/2022]
Abstract
Nowadays, it is still a challenge for commercial nitrate sensors to meet the requirement of high accuracy in a complex water. Based on deep-ultraviolet spectral analysis and a regression algorithm, a different measuring method for obtaining the concentration of nitrate in seawater is proposed in this paper. The system consists of a deuterium lamp, an optical fiber splitter module, a reflection probe, temperature and salinity sensors, and a deep-ultraviolet spectrometer. The regression model based on weighted average kernel partial least squares (WA-KPLS) algorithm together with corrections for temperature and salinity (TSC) is established. After that, the seawater samples from Western Pacific and Aoshan Bay in Qingdao, China with the addition of various nitrate concentrations are studied to verify the reliability and accuracy of the method. The results show that the TSC-WA-KPLS algorithm shows the best results when compared against the multiple linear regression (MLR) and ISUS (in situ ultraviolet spectrophotometer) algorithms in the temperatures range of 4–25 °C, with RMSEP of 0.67 µmol/L for Aoshan Bay seawater and 1.08 µmol/L for Western Pacific seawater. The method proposed in this paper is suitable for measuring the nitrate concentration in seawater with higher accuracy, which could find application in the development of in-situ and real-time nitrate sensors.
Collapse
|