1
|
Choi MH, Booth W, Edwards B, Timperman AT. Electroneutral Layer Dynamics Drive Ion Migration in Low Frequency AC Electrophoresis Below the Water Electrolysis Threshold. Anal Chem 2024. [PMID: 39010789 DOI: 10.1021/acs.analchem.4c01501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/17/2024]
Abstract
Low-frequency AC electrophoresis lies in a regime between DC microchannel electrophoresis and dielectrophoresis, which typically utilizes frequencies above 1000 Hz. Although few electrophoretic methods have been reported in this ≤100 Hz range, traveling wave electrophoresis (TWE) and transverse AC electrophoresis (TrACE) operate in this frequency range, and use low voltages to avoid bubble formation from water electrolysis. TWE provides molecular separations with enhanced control and TrACE provides multiplexed, multiparameter particle characterization. However, two related fundamental questions remain about the mechanisms of electrophoretic migration in these systems. First, particle electrophoresis in TrACE is largely captured by a simple model that combines the alternating electric field with DC electrokinetics, but a deviation from the model is observed for applied square electric field waves that increases with decreasing frequency. Second, although electrode charging is believed to drive ion migration in TWE, the estimated electrode charging time is about 2-3 orders of magnitude faster than the wave period. In this study, a 1D finite numerical model that excludes Faradaic reactions simulates ion and particle migration across the microchannel width in TrACE. The 1D model results show good agreement with both particle and ion migration in TrACE systems. Furthermore, although ion migration between the pair of electrodes slows during each excursion of a 1 Hz square wave, there is substantial ion migration throughout the 0.5 s half-period. This modeling result agrees with experimental observations in TWE. Therefore, the clarification of the mechanisms of ion migration in these low-frequency and low-voltage AC electrophoresis is expected to expand their applications.
Collapse
Affiliation(s)
- M Hannah Choi
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - William Booth
- The Terra Academy, Vernal, Utah 84078, United States
| | - Boyd Edwards
- Department of Physics, Utah State University, Logan, Utah 84322, United States
| | - Aaron T Timperman
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
- Department of Biochemistry and Biophysics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| |
Collapse
|
2
|
Wang Y, Chen J, Zhang Y, Yang Z, Zhang K, Zhang D, Zheng L. Advancing Microfluidic Immunity Testing Systems: New Trends for Microbial Pathogen Detection. Molecules 2024; 29:3322. [PMID: 39064900 PMCID: PMC11279515 DOI: 10.3390/molecules29143322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Revised: 07/10/2024] [Accepted: 07/12/2024] [Indexed: 07/28/2024] Open
Abstract
Pathogenic microorganisms play a crucial role in the global disease burden due to their ability to cause various diseases and spread through multiple transmission routes. Immunity tests identify antigens related to these pathogens, thereby confirming past infections and monitoring the host's immune response. Traditional pathogen detection methods, including enzyme-linked immunosorbent assays (ELISAs) and chemiluminescent immunoassays (CLIAs), are often labor-intensive, slow, and reliant on sophisticated equipment and skilled personnel, which can be limiting in resource-poor settings. In contrast, the development of microfluidic technologies presents a promising alternative, offering automation, miniaturization, and cost efficiency. These advanced methods are poised to replace traditional assays by streamlining processes and enabling rapid, high-throughput immunity testing for pathogens. This review highlights the latest advancements in microfluidic systems designed for rapid and high-throughput immunity testing, incorporating immunosensors, single molecule arrays (Simoas), a lateral flow assay (LFA), and smartphone integration. It focuses on key pathogenic microorganisms such as SARS-CoV-2, influenza, and the ZIKA virus (ZIKV). Additionally, the review discusses the challenges, commercialization prospects, and future directions to advance microfluidic systems for infectious disease detection.
Collapse
Affiliation(s)
- Yiran Wang
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Jingwei Chen
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Yule Zhang
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Zhijin Yang
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Kaihuan Zhang
- 2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
| | - Dawei Zhang
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China
- Shanghai Engineering Research Center of Environmental Biosafety Instruments and Equipment, University of Shanghai for Science and Technology, Shanghai 200093, China
- Shanghai Institute of Intelligent Science and Technology, Tongji University, Shanghai 200092, China
| | - Lulu Zheng
- Engineering Research Center of Optical Instrument and System, The Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China
- Shanghai Engineering Research Center of Environmental Biosafety Instruments and Equipment, University of Shanghai for Science and Technology, Shanghai 200093, China
| |
Collapse
|
3
|
Boonkaew S, Szot-Karpińska K, Niedziółka-Jönsson J, de Marco A, Jönsson-Niedziółka M. NFC Smartphone-Based Electrochemical Microfluidic Device Integrated with Nanobody Recognition for C-Reactive Protein. ACS Sens 2024; 9:3066-3074. [PMID: 38877998 PMCID: PMC11217940 DOI: 10.1021/acssensors.4c00249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 06/04/2024] [Accepted: 06/07/2024] [Indexed: 06/29/2024]
Abstract
Point-of-care testing (POCT) devices play a crucial role as tools for disease diagnostics, and the integration of biorecognition elements with electronic components into these devices widens their functionalities and facilitates the development of complex quantitative assays. Unfortunately, biosensors that exploit large conventional IgG antibodies to capture relevant biomarkers are often limited in terms of sensitivity, selectivity, and storage stability, considerably restricting the use of POCT in real-world applications. Therefore, we used nanobodies as they are more suitable for fabricating electrochemical biosensors with near-field communication (NFC) technology. Moreover, a flow-through microfluidic device was implemented in this system for the detection of C-reactive protein (CRP), an inflammation biomarker, and a model analyte. The resulting sensors not only have high sensitivity and portability but also retain automated sequential flow properties through capillary transport without the need for an external pump. We also compared the accuracy of CRP quantitative analyses between commercial PalmSens4 and NFC-based potentiostats. Furthermore, the sensor reliability was evaluated using three biological samples (artificial serum, plasma, and whole blood without any pretreatment). This platform will streamline the development of POCT devices by combining operational simplicity, low cost, fast analysis, and portability.
Collapse
Affiliation(s)
- Suchanat Boonkaew
- Institute
of Physical Chemistry, Polish Academy of
Sciences, Kasprzaka 44/52, Warsaw 01-224, Poland
| | - Katarzyna Szot-Karpińska
- Institute
of Physical Chemistry, Polish Academy of
Sciences, Kasprzaka 44/52, Warsaw 01-224, Poland
| | | | - Ario de Marco
- Laboratory
for Environmental and Life Sciences, University
of Nova Gorica, Vipavska
cesta 13, 5000 Nova
Gorica, Slovenia
| | | |
Collapse
|
4
|
Rasekh M, Harrison S, Schobesberger S, Ertl P, Balachandran W. Reagent storage and delivery on integrated microfluidic chips for point-of-care diagnostics. Biomed Microdevices 2024; 26:28. [PMID: 38825594 DOI: 10.1007/s10544-024-00709-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/02/2024] [Indexed: 06/04/2024]
Abstract
Microfluidic-based point-of-care diagnostics offer several unique advantages over existing bioanalytical solutions, such as automation, miniaturisation, and integration of sensors to rapidly detect on-site specific biomarkers. It is important to highlight that a microfluidic POC system needs to perform a number of steps, including sample preparation, nucleic acid extraction, amplification, and detection. Each of these stages involves mixing and elution to go from sample to result. To address these complex sample preparation procedures, a vast number of different approaches have been developed to solve the problem of reagent storage and delivery. However, to date, no universal method has been proposed that can be applied as a working solution for all cases. Herein, both current self-contained (stored within the chip) and off-chip (stored in a separate device and brought together at the point of use) are reviewed, and their merits and limitations are discussed. This review focuses on reagent storage devices that could be integrated with microfluidic devices, discussing further issues or merits of these storage solutions in two different sections: direct on-chip storage and external storage with their application devices. Furthermore, the different microvalves and micropumps are considered to provide guidelines for designing appropriate integrated microfluidic point-of-care devices.
Collapse
Affiliation(s)
- Manoochehr Rasekh
- College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge, UB8 3PH, UK.
| | - Sam Harrison
- College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge, UB8 3PH, UK
| | - Silvia Schobesberger
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry, Vienna University of Technology, Getreidemarkt 9, 1060, Vienna, Austria
| | - Peter Ertl
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry, Vienna University of Technology, Getreidemarkt 9, 1060, Vienna, Austria
| | - Wamadeva Balachandran
- College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge, UB8 3PH, UK.
| |
Collapse
|
5
|
Yang C, Yin D, Zhang H, Badea I, Yang SM, Zhang W. Cell Migration Assays and Their Application to Wound Healing Assays-A Critical Review. MICROMACHINES 2024; 15:720. [PMID: 38930690 PMCID: PMC11205366 DOI: 10.3390/mi15060720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 05/20/2024] [Accepted: 05/24/2024] [Indexed: 06/28/2024]
Abstract
In recent years, cell migration assays (CMAs) have emerged as a tool to study the migration of cells along with their physiological responses under various stimuli, including both mechanical and bio-chemical properties. CMAs are a generic system in that they support various biological applications, such as wound healing assays. In this paper, we review the development of the CMA in the context of its application to wound healing assays. As such, the wound healing assay will be used to derive the requirements on CMAs. This paper will provide a comprehensive and critical review of the development of CMAs along with their application to wound healing assays. One salient feature of our methodology in this paper is the application of the so-called design thinking; namely we define the requirements of CMAs first and then take them as a benchmark for various developments of CMAs in the literature. The state-of-the-art CMAs are compared with this benchmark to derive the knowledge and technological gap with CMAs in the literature. We will also discuss future research directions for the CMA together with its application to wound healing assays.
Collapse
Affiliation(s)
- Chun Yang
- School of Mechanical Engineering, Donghua University, Shanghai 200051, China;
- Division of Biomedical Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Di Yin
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237, China; (D.Y.); (H.Z.)
| | - Hongbo Zhang
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237, China; (D.Y.); (H.Z.)
| | - Ildiko Badea
- College of Pharmacy and Nutrition, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada;
| | - Shih-Mo Yang
- School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200444, China
| | - Wenjun Zhang
- School of Mechanical Engineering, Donghua University, Shanghai 200051, China;
- Division of Biomedical Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| |
Collapse
|
6
|
Chen W, Li J, Wang P, Ma S, Li B. Study on the Flow Field Distribution in Microfluidic Cells for Surface Plasmon Resonance Array Detection. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2426. [PMID: 38793492 PMCID: PMC11122974 DOI: 10.3390/ma17102426] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 04/19/2024] [Accepted: 04/25/2024] [Indexed: 05/26/2024]
Abstract
This research is dedicated to optimizing the design of microfluidic cells to minimize mass transfer effects and ensure a uniform flow field distribution, which is essential for accurate SPR array detection. Employing finite element simulations, this study methodically explored the internal flow dynamics within various microfluidic cell designs to assess the impact of different contact angles on flow uniformity. The cells, constructed from Polydimethylsiloxane (PDMS), were subjected to micro-particle image velocimetry to measure flow velocities in targeted sections. The results demonstrate that a contact angle of 135° achieves the most uniform flow distribution, significantly enhancing the capability for high-throughput array detection. While the experimental results generally corroborated the simulations, minor deviations were observed, likely due to fabrication inaccuracies. The microfluidic cells, evaluated using a custom-built SPR system, showed consistent repeatability.
Collapse
Affiliation(s)
- Wanwan Chen
- Department of Precision Instrument, Tsinghua University, Beijing 100084, China; (P.W.)
| | - Jing Li
- College of Mechanical Engineering, Yangzhou University, Yangzhou 225012, China
| | - Peng Wang
- Department of Precision Instrument, Tsinghua University, Beijing 100084, China; (P.W.)
| | - Shuai Ma
- College of Environmental Science and Engineering, Yangzhou University, Yangzhou 225012, China
| | - Bin Li
- Department of Precision Instrument, Tsinghua University, Beijing 100084, China; (P.W.)
- Research Institute of Tsinghua, Pearl River Delta, Guangzhou 510530, China
| |
Collapse
|
7
|
Smith S, Sypabekova M, Kim S. Double-Sided Tape in Microfluidics: A Cost-Effective Method in Device Fabrication. BIOSENSORS 2024; 14:249. [PMID: 38785723 PMCID: PMC11118809 DOI: 10.3390/bios14050249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Revised: 04/17/2024] [Accepted: 05/09/2024] [Indexed: 05/25/2024]
Abstract
The demand for easy-to-use, affordable, accessible, and reliable technology is increasing in biological, chemical, and medical research. Microfluidic devices have the potential to meet these standards by offering cost-effective, highly sensitive, and highly specific diagnostic tests with rapid performance and minimal sample volumes. Traditional microfluidic device fabrication methods, such as photolithography and soft lithography, are time-consuming and require specialized equipment and expertise, making them costly and less accessible to researchers and clinicians and limiting the applicability and potential of microfluidic devices. To address this, researchers have turned to using new low-cost materials, such as double-sided tape for microfluidic device fabrication, which offers simple and low-cost processes. The innovation of low-cost and easy-to-make microfluidic devices improves the potential for more devices to be transitioned from laboratories to commercialized products found in stores, offices, and homes. This review serves as a comprehensive summary of the growing interest in and use of double-sided tape-based microfluidic devices in the last 20 years. It discusses the advantages of using double-sided tape, the fabrication techniques used to create and bond microfluidic devices, and the limitations of this approach in certain applications.
Collapse
Affiliation(s)
| | | | - Seunghyun Kim
- Department of Electrical & Computer Engineering, Baylor University, Waco, TX 76798, USA; (S.S.); (M.S.)
| |
Collapse
|
8
|
Xu F, Ma L, Fan Y. Air trap and removal on a pressure driven PDMS-based microfluidic device. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2024; 95:055003. [PMID: 38739426 DOI: 10.1063/5.0190337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 04/23/2024] [Indexed: 05/14/2024]
Abstract
With the development of microfluidic technology, microfluidic chips have played a positive role in applications such as cell culture, microfluidic PCR, and nanopore gene sequencing. However, the presence of bubbles interferes with fluid flow and has a significant impact on experimental results. There are many reasons for the generation of bubbles in microfluidic chips, such as pressure changes inside the chip, air vibration inside the chip, and the open chip guiding air into the chip when driving fluid. This study designed and prepared a microfluidic device based on polydimethylsiloxane. First, air was actively introduced into the microfluidic chip, and bubbles were captured through the microfluidic device to simulate the presence of bubbles inside the chip in biological experiments. To remove bubbles trapped in the microfluidic chip, distilled water, distilled water containing surfactants, and mineral oil were pumped into the microfluidic chip. We compared and discussed the bubble removal efficiency under different driving fluids, driving pressures, and open/closed channel configurations. This study helps to understand the mechanism of bubble formation and removal in microfluidic devices, optimize chip structure design and experimental reagent selection, prevent or eliminate bubbles, and reduce the impact of bubbles on experiments.
Collapse
Affiliation(s)
- Fan Xu
- School of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing 100029, China
| | - Liang Ma
- Department of Clinical Laboratory, China-Japan Friendship Hospital, Beijing 100029, China
| | - Yiqiang Fan
- School of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing 100029, China
| |
Collapse
|
9
|
Liu Y, Su G, Wang W, Wei H, Dang L. A novel multifunctional SERS microfluidic sensor based on ZnO/Ag nanoflower arrays for label-free ultrasensitive detection of bacteria. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2085-2092. [PMID: 38511545 DOI: 10.1039/d4ay00018h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/22/2024]
Abstract
This study proposes a microfluidic platform for rapid enrichment and ultrasensitive SERS detection of bacteria. The platform comprises ZnO nanoflower arrays decorated with silver nanoparticles to enhance the SERS sensitivity. The ZnO nanoflower array substrate with a 3D reticular columnar structure is prepared using the hydrothermal method. SEM analysis depicts the 3.05 μm gap distribution of the substrate array to intercept the most bacteria in the particle sizes range of 0.5 to 3 μm. Then, silver nanoparticles are deposited on the ZnO nano-array surface by liquid evaporation self-assembly. TEM and SEM analysis indicate nanosize of Ag particles, evenly distributed on the substrate, enhancing the SERS efficiency and improving sensing reproducibility. The probe molecules (R6G) are tested to demonstrate the high SERS activity of the proposed microfluidic sensor. Then, Escherichia coli, Staphylococcus aureus, Enterococcus faecalis, and Bacillus subtilis are selected, demonstrating the sensor's excellent bacterial capture and sensitive recognition capabilities, with a detection limit as low as 102 CFU mL-1. Additionally, the antibacterial properties of ZnO/Ag heterojunction nanostructures are studied, suggesting their ability to inactivate bacteria. Compared with the traditional Au-enhanced chip, the sensor preparation is easy, safe, reliable, and low-cost. Moreover, the ZnO nano-array exhibits a large specific surface area, high interception ability, stronger and uniform SERS performance, and effective and reliable detection of trace pathogens. This work provides potential future ZnO/Ag microfluidic SERS sensor applications for rapid, unlabeled, and trace pathogens detection in clinical and environmental applications, potentially achieving breakthroughs in early detection, prevention, and treatment.
Collapse
Affiliation(s)
- Yue Liu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, China.
| | - Guanwen Su
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, China.
| | - Wei Wang
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, China.
| | - Hongyuan Wei
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, China.
| | - Leping Dang
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, China.
| |
Collapse
|
10
|
Sengupta J, Hussain CM. Point-of-care devices engaging green graphene: an eco-conscious and sustainable paradigm. NANOSCALE 2024; 16:6900-6914. [PMID: 38511341 DOI: 10.1039/d3nr06367d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/22/2024]
Abstract
The healthcare landscape has experienced a profound and irreversible transformation, primarily driven by the emergence of nanomaterial-assisted point-of-care (POC) devices. The inclusion of nanomaterials in POC devices has revolutionized healthcare by enabling rapid, on-site diagnostics with minimal infrastructure requirements. Among the materials poised to lead this technological revolution, green graphene emerges as a compelling contender. It possesses a unique combination of exceptional material properties and environmentally conscious attributes. These attributes include its substantial surface area, unparalleled electrical conductivity, and inherent biocompatibility. This article embarks on an exploration of POC devices incorporating green graphene. It meticulously dissects the intricacies of their design, performance characteristics, and diverse applications. Throughout the exposition, the transformative impact of green graphene on the advancement of POC diagnostics takes centre stage. It underscores the material's potential to drive sustainable and effective healthcare solutions, marking a significant milestone in the evolution of healthcare technology.
Collapse
Affiliation(s)
- Joydip Sengupta
- Department of Electronic Science, Jogesh Chandra Chaudhuri College, Kolkata-700033, India.
| | - Chaudhery Mustansar Hussain
- Department of Chemistry and Environmental Science, New Jersey Institute of Technology, Newark, 07102, New Jersey, USA.
| |
Collapse
|
11
|
Han DH, Lee G, Oh U, Choi Y, Park JK. Evaluation of Fluid Behaviors in a Pushbutton-Activated Microfluidic Device for User-Independent Flow Control. MICROMACHINES 2024; 15:465. [PMID: 38675276 PMCID: PMC11052212 DOI: 10.3390/mi15040465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 03/27/2024] [Accepted: 03/28/2024] [Indexed: 04/28/2024]
Abstract
Although numerous studies have been conducted to realize ideal point-of-care testing (POCT), the development of a user-friendly and user-independent power-free microfluidic platform is still a challenge. Among various methods, the finger-actuation method shows a promising technique that provides a user-friendly and equipment-free way of delivering fluid in a designated manner. However, the design criteria and elaborate evaluation of the fluid behavior of a pushbutton-activated microfluidic device (PAMD) remain a critical bottleneck to be widely adopted in various applications. In this study, we have evaluated the fluid behavior of the PAMD based on various parameters, such as pressing velocity and depth assisted by a press machine. We have further developed a user-friendly and portable pressing block that reduces user variation in fluid behavior based on the evaluation.
Collapse
Affiliation(s)
- Dong Hyun Han
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea; (D.H.H.); (G.L.); (U.O.); (Y.C.)
| | - Gihyun Lee
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea; (D.H.H.); (G.L.); (U.O.); (Y.C.)
| | - Untaek Oh
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea; (D.H.H.); (G.L.); (U.O.); (Y.C.)
| | - Yejin Choi
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea; (D.H.H.); (G.L.); (U.O.); (Y.C.)
| | - Je-Kyun Park
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea; (D.H.H.); (G.L.); (U.O.); (Y.C.)
- KI for Health Science and Technology, KAIST Institutes (KI), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
- KI for NanoCentury, KAIST Institutes (KI), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| |
Collapse
|
12
|
Kumar AS, Venkatesalu S, Dilliyappan S, Pasupulla AP, Prathap L, Palaniyandi T, Baskar G, Ravi M, Sugumaran A. Microfluidics as diagnostic tools. Clin Chim Acta 2024; 556:117841. [PMID: 38395126 DOI: 10.1016/j.cca.2024.117841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Revised: 02/17/2024] [Accepted: 02/18/2024] [Indexed: 02/25/2024]
Abstract
The challenges in the management of human diseases are largely determined by the precision, speed and ease of diagnostic procedures available. Developments in biomedical engineering technologies have greatly helped in transforming human health care, especially for disease diagnosis which in turn lead to better patient outcomes. One such development is in the form of microfluidic chip technology which has transformed various aspects of human health care. We present in this review, a comprehensive account on the utility of microfluidic chip technologies for the diagnosis of autoimmune disorders, cardiovascular diseases (CVDs), infectious diseases, and neurodegenerative conditions. We have included the diseases posing global threat such as rheumatoid arthritis, diabetes, pernicious anemia, tuberculosis, COVID-19, influenza, alzheimer's, multiple sclerosis, and epilepsy. Apart from discussing the ways of microfluidic chip in diagnosis, we included a section presenting electrochemical, electrical, optical, and acoustic detection technologies for the precise diagnosis of CVDs. Microfluidics platforms have thus revolutionized novel capabilities in addressing the requirements of point-of-care diagnostics enabling miniaturization by integrating multiple laboratory functions into a single chip resulting in "one flow - one solution" systems. Hence, the precision and early diagnoses of diseases are now possible due to the advancements of microfluidics-based technology.
Collapse
Affiliation(s)
- Avanthika Satish Kumar
- Department of Biotechnology, Dr. M.G.R. Educational and Research Institute, Chennai, India
| | - Sneha Venkatesalu
- Department of Biotechnology, Dr. M.G.R. Educational and Research Institute, Chennai, India
| | | | - Ajay Prakash Pasupulla
- Oral and Maxillofacial Pathologist, School of Medicine, College of Health Sciences, Nigist Eleni Comprehensive Specialized Hospital, Wachemo University, Hossana, Ethiopia, East Africa
| | - Lavanya Prathap
- Department of Anatomy, Biomedical Research Unit and Laboratory Animal Centre, Saveetha Dental College and Hospital, SIMATS, Saveetha University, Chennai, India
| | - Thirunavukkarasu Palaniyandi
- Department of Biotechnology, Dr. M.G.R. Educational and Research Institute, Chennai, India; Department of Anatomy, Biomedical Research Unit and Laboratory Animal Centre, Saveetha Dental College and Hospital, SIMATS, Saveetha University, Chennai, India.
| | - Gomathy Baskar
- Department of Biotechnology, Dr. M.G.R. Educational and Research Institute, Chennai, India
| | - Maddaly Ravi
- Department of Human Genetics, Sri Ramachandra Institute of Higher Education and Research, Chennai, India
| | - Abimanyu Sugumaran
- Department of Pharmaceutical Sciences, Assam University, Silchar, Assam, India
| |
Collapse
|
13
|
Zhou X, Liu X, Zhao H, Guo G, Jiang X, Liu S, Sun X, Yang H. Research advances in microfluidic collection and detection of virus, bacterial, and fungal bioaerosols. Mikrochim Acta 2024; 191:132. [PMID: 38351367 DOI: 10.1007/s00604-024-06213-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Accepted: 01/14/2024] [Indexed: 02/16/2024]
Abstract
Bioaerosols are airborne suspensions of fine solid or liquid particles containing biological substances such as viruses, bacteria, cellular debris, fungal spores, mycelium, and byproducts of microbial metabolism. The global Coronavirus disease 2019 (COVID-19) pandemic and the previous emergence of severe acute respiratory syndrome (SARS), Middle East respiratory syndrome (MERS), and influenza have increased the need for reliable and effective monitoring tools for bioaerosols. Bioaerosol collection and detection have aroused considerable attention. Current bioaerosol sampling and detection techniques suffer from long response time, low sensitivity, and high costs, and these drawbacks have forced the development of novel monitoring strategies. Microfluidic technique is considered a breakthrough for high performance analysis of bioaerosols. In recent years, several emerging methods based on microfluidics have been developed and reported for collection and detection of bioaerosols. The unique advantages of microfluidic technique have enabled the integration of bioaerosol collection and detection, which has a higher efficiency over conventional methods. This review focused on the research progress of bioaerosol collection and detection methods based on microfluidic techniques, with special attention on virus aerosols and bacterial aerosols. Different from the existing reviews, this work took a unique perspective of the targets to be collected and detected in bioaerosols, which would provide a direct index of bioaerosol categories readers may be interested in. We also discussed integrated microfluidic monitoring system for bioaerosols. Additionally, the application of bioaerosol detection in biomedicine was presented. Finally, the current challenges in the field of bioaerosol monitoring are presented and an outlook given of future developments.
Collapse
Affiliation(s)
- Xinyue Zhou
- Department of Respiratory Medicine, The Fourth Hospital of China Medical University, No. 4, Chongshan East Road, Huanggu District, Shenyang, 110032, Liaoning, China
| | - Xin Liu
- Department of Respiratory Medicine, The Fourth Hospital of China Medical University, No. 4, Chongshan East Road, Huanggu District, Shenyang, 110032, Liaoning, China
| | - Haiyang Zhao
- Teaching Center for Basic Medical Experiment, China Medical University, No.77, Puhe Road, Shenyang, 110122, Liaoning Province, China
| | - Guanqi Guo
- Teaching Center for Basic Medical Experiment, China Medical University, No.77, Puhe Road, Shenyang, 110122, Liaoning Province, China
| | - Xiran Jiang
- School of Intelligent Medicine, China Medical University, No.77, Puhe Road, Shenyang, 110122, Liaoning Province, China.
| | - Shuo Liu
- Department of Respiratory Medicine, The Fourth Hospital of China Medical University, No. 4, Chongshan East Road, Huanggu District, Shenyang, 110032, Liaoning, China.
| | - Xiaoting Sun
- School of Forensic Medicine, China Medical University, No.77, Puhe Road, Shenyang, 110122, Liaoning Province, China.
| | - Huazhe Yang
- School of Intelligent Medicine, China Medical University, No.77, Puhe Road, Shenyang, 110122, Liaoning Province, China.
| |
Collapse
|
14
|
Louw CJ, de Haan P, Verpoorte E, Baker P. Efficient Electrochemiluminescence Sensing in Microfluidic Biosensors: A Review. Crit Rev Biomed Eng 2024; 52:41-62. [PMID: 38523440 DOI: 10.1615/critrevbiomedeng.2023049565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/26/2024]
Abstract
Microfluidic devices are capable of handling 10-9 L to 10-18 L of fluids by incorporating tiny channels with dimensions of ten to hundreds of micrometers, and they can be fabricated using a wide range of materials including glass, silicon, polymers, paper, and cloth for tailored sensing applications. Microfluidic biosensors integrated with detection methods such as electrochemiluminescence (ECL) can be used for the diagnosis and prognosis of diseases. Coupled with ECL, these tandem devices are capable of sensing biomarkers at nanomolar to picomolar concentrations, reproducibly. Measurement at this low level of concentration makes microfluidic electrochemiluminescence (MF-ECL) devices ideal for biomarker detection in the context of early warning systems for diseases such as myocardial infarction, cancer, and others. However, the technology relies on the nature and inherent characteristics of an efficient luminophore. The luminophore typically undergoes a redox process to generate excited species which emit energy in the form of light upon relaxation to lower energy states. Therefore, in biosensor design the efficiency of the luminophore is critical. This review is focused on the integration of microfluidic devices with biosensors and using electrochemiluminescence as a detection method. We highlight the dual role of carbon quantum dots as a luminophore and co-reactant in electrochemiluminescence analysis, drawing on their unique properties that include large specific surface area, easy functionalization, and unique luminescent properties.
Collapse
Affiliation(s)
- Clementine Juliat Louw
- SensorLab, Chemistry Department, University of the Western Cape, Cape Town, South Africa; Pharmaceutical Analysis, Groningen Research Institute of Pharmacy, University of Groningen, Groningen, the Netherlands
| | - Pim de Haan
- Pharmaceutical Analysis, Groningen Research Institute of Pharmacy, University of Groningen, Groningen, the Netherlands
| | - Elisabeth Verpoorte
- Pharmaceutical Analysis, Groningen Research Institute of Pharmacy, University of Groningen, Groningen, the Netherlands
| | - Priscilla Baker
- Department of Chemistry, University of the Western Cape Bellville, 7535, Republic of South Africa
| |
Collapse
|
15
|
Zhang L, Guo W, Lv C. Modern technologies and solutions to enhance surveillance and response systems for emerging zoonotic diseases. SCIENCE IN ONE HEALTH 2023; 3:100061. [PMID: 39077381 PMCID: PMC11262286 DOI: 10.1016/j.soh.2023.100061] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 10/29/2023] [Indexed: 07/31/2024]
Abstract
Background Zoonotic diseases originating in animals pose a significant threat to global public health. Recent outbreaks, such as coronavirus disease 2019 (COVID-19), have caused widespread illness, death, and socioeconomic disruptions worldwide. To cope with these diseases effectively, it is crucial to strengthen surveillance capabilities and establish rapid response systems. Aim The aim of this review to examine the modern technologies and solutions that have the potential to enhance zoonotic disease surveillance and outbreak responses and provide valuable insights into how cutting-edge innovations could be leveraged to prevent, detect, and control emerging zoonotic disease outbreaks. Herein, we discuss advanced tools including big data analytics, artificial intelligence, the Internet of Things, geographic information systems, remote sensing, molecular diagnostics, point-of-care testing, telemedicine, digital contact tracing, and early warning systems. Results These technologies enable real-time monitoring, the prediction of outbreak risks, early anomaly detection, rapid diagnosis, and targeted interventions during outbreaks. When integrated through collaborative partnerships, these strategies can significantly improve the speed and effectiveness of zoonotic disease control. However, several challenges persist, particularly in resource-limited settings, such as infrastructure limitations, costs, data integration and training requirements, and ethical implementation. Conclusion With strategic planning and coordinated efforts, modern technologies and solutions offer immense potential to bolster surveillance and outbreak responses, and serve as a critical resource against emerging zoonotic disease threats worldwide.
Collapse
Affiliation(s)
- Li Zhang
- Huazhong Agricultural University, Wuhan 430070, China
| | - Wenqiang Guo
- Huazhong Agricultural University, Wuhan 430070, China
| | - Chenrui Lv
- Huazhong Agricultural University, Wuhan 430070, China
| |
Collapse
|
16
|
Kikkeri K, Naba FM, Voldman J. Rapid, low-cost fabrication of electronic microfluidics via inkjet-printing and xurography (MINX). Biosens Bioelectron 2023; 237:115499. [PMID: 37473550 DOI: 10.1016/j.bios.2023.115499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 06/23/2023] [Accepted: 06/24/2023] [Indexed: 07/22/2023]
Abstract
Microfluidics has shown great promise for point-of-care assays due to unique chemical and physical advantages that occur at the micron scale. Furthermore, integration of electrodes into microfluidic systems provides additional capabilities for assay operation and electronic readout. However, while these systems are abundant in biological and biomedical research settings, translation of microfluidic devices with embedded electrodes are limited. In part, this is due to the reliance on expensive, inaccessible, and laborious microfabrication techniques. Although innovative prior work has simplified microfluidic fabrication or inexpensively patterned electrodes, low-cost, accessible, and robust methods to incorporate all these elements are lacking. Here, we present MINX, a low-cost <1 USD and rapid (∼minutes) fabrication technique to manufacture microfluidic device with embedded electrodes. We characterize the structures created using MINX, and then demonstrate the utility of the approach by using MINX to implement an electrochemical bead-based biomarker detection assay. We show that the MINX technique enables the scalable, inexpensive fabrication of microfluidic devices with electronic sensors using widely accessible desktop machines and low-cost materials.
Collapse
Affiliation(s)
- Kruthika Kikkeri
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Feven Moges Naba
- Department of Biomedical Engineering, Columbia University, New York, NY, 10027, USA
| | - Joel Voldman
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA.
| |
Collapse
|
17
|
Lakbar I, Singer M, Leone M. 2030: will we still need our microbiologist? Intensive Care Med 2023; 49:1232-1234. [PMID: 37606739 DOI: 10.1007/s00134-023-07186-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 07/30/2023] [Indexed: 08/23/2023]
Affiliation(s)
- Ines Lakbar
- Anesthesiology and Intensive Care, Anesthesia and Critical Care Department B, Département d'Anesthésie Réanimation B (DAR B), Saint Eloi Teaching Hospital, PhyMedExp, University of Montpellier, INSERM U1046, 1, 80 Avenue Augustin Fliche, 34295, Montpellier Cedex 5, France.
| | - Mervyn Singer
- Bloomsbury Institute of Intensive Care Medicine, University College London, London, UK
| | - Marc Leone
- Department of Anesthesiology and Intensive Care Unit, North Hospital, Assistance Publique Hôpitaux, Service D'anesthésie Et de Réanimation, Hôpital Nord, Chemin Des Bourrely, Universitaires de Marseille, Aix Marseille University, 13015, Marseille, France
- Centre for Nutrition and Cardiovascular Disease (C2VN), INSERM, INRAE, Aix Marseille University, 13005, Marseille, France
| |
Collapse
|
18
|
Fang Q, Cao S, Qin H, Yin R, Zhang W, Zhang H. A Novel Mechanomyography (MMG) Sensor Based on Piezo-Resistance Principle and with a Pyramidic Microarray. MICROMACHINES 2023; 14:1859. [PMID: 37893296 PMCID: PMC10609147 DOI: 10.3390/mi14101859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 09/08/2023] [Accepted: 09/25/2023] [Indexed: 10/29/2023]
Abstract
Flexible piezoresistive sensors built by printing nanoparticles onto soft substrates are crucial for continuous health monitoring and wearable devices. In this study, a mechanomyography (MMG) sensor was developed using a flexible piezoresistive MMG signal sensor based on a pyramidal polydimethylsiloxane (PDMS) microarray sprayed with carbon nanotubes (CNTs). The experiment was conducted, and the results show that the sensitivity of the sensor can reach 0.4 kPa-1 in the measurement range of 0~1.5 kPa, and the correlation reached 96%. This has further implications for the possibility that muscle activation can be converted into mechanical movement. The integrity of the sensor in terms of its MMG signal acquisition was tested based on five subjects who were performing arm bending and arm extending movements. The results of this test were promising.
Collapse
Affiliation(s)
- Qize Fang
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Shuchen Cao
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Haotian Qin
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Ruixue Yin
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Wenjun Zhang
- Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada;
| | - Hongbo Zhang
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237, China
| |
Collapse
|
19
|
Laman A, Das D, Priye A. Miniaturized Non-Contact Heating and Transmitted Light Imaging Using an Inexpensive and Modular 3D-Printed Platform for Molecular Diagnostics. SENSORS (BASEL, SWITZERLAND) 2023; 23:7718. [PMID: 37765775 PMCID: PMC10535971 DOI: 10.3390/s23187718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 09/04/2023] [Accepted: 09/05/2023] [Indexed: 09/29/2023]
Abstract
The ability to simultaneously heat and image samples using transmitted light is crucial for several biological applications. However, existing techniques such as heated stage microscopes, thermal cyclers equipped with imaging capabilities, or non-contact heating systems are often bulky, expensive, and complex. This work presents the development and characterization of a Miniaturized Optically-clear Thermal Enclosure (MOTE) system-an open-source, inexpensive, and low-powered modular system-capable of convectively heating samples while simultaneously imaging them with transmitted light. We develop and validate a computational fluid dynamics (CFD) model to design and optimize the heating chamber. The model simulates velocity and temperature profiles within the heating chamber for various chamber materials and sizes. The computational model yielded an optimal chamber dimension capable of achieving a stable temperature ranging from ambient to 95 °C with a spatial discrepancy of less than 1.5 °C, utilizing less than 8.5 W of power. The dual-functionality of the MOTE system, enabling synchronous heating and transmitted light imaging, was demonstrated through the successful execution of paper-based LAMP reactions to detect λ DNA samples in real-time down to 10 copies/µL of the target concentration. The MOTE system offers a promising and flexible platform for various applications, from molecular diagnostics to biochemical analyses, cell biology, genomics, and education.
Collapse
Affiliation(s)
- Alex Laman
- Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH 45221, USA;
| | - Debayan Das
- Chemical Engineering Department, NIT Durgapur, Mahatma Gandhi Rd., A-Zone, Durgapur 713209, West Bengal, India;
| | - Aashish Priye
- Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH 45221, USA;
- Digital Futures, University of Cincinnati, Cincinnati, OH 45221, USA
| |
Collapse
|
20
|
Voit F, Erber J, Feuerherd M, Fries H, Bitterlich N, Diehl-Wiesenecker E, Gladis S, Lieb J, Protzer U, Schneider J, Geisler F, Somasundaram R, Schmid RM, Bauer W, Spinner CD. Rapid point-of-care detection of SARS-CoV-2 infection in exhaled breath using ion mobility spectrometry: a pilot study. Eur J Med Res 2023; 28:318. [PMID: 37660038 PMCID: PMC10474630 DOI: 10.1186/s40001-023-01284-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Accepted: 08/12/2023] [Indexed: 09/04/2023] Open
Abstract
BACKGROUND An effective testing strategy is essential for pandemic control of the novel Coronavirus disease 2019 (COVID-19) caused by infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Breath gas analysis can expand the available toolbox for diagnostic tests by using a rapid, cost-beneficial, high-throughput point-of-care test. We conducted a bi-center clinical pilot study in Germany to evaluate breath gas analysis using multi-capillary column ion mobility spectrometry (MCC-IMS) to detect SARS-CoV-2 infection. METHODS Between September 23, 2020, and June 11, 2021, breath gas measurements were performed on 380 patients (SARS-CoV-2 real-time polymerase chain reaction (PCR) positive: 186; PCR negative: 194) presenting to the emergency department (ED) with respiratory symptoms. RESULTS Breath gas analysis using MCC-IMS identified 110 peaks; 54 showed statistically significant differences in peak intensity between the SARS-CoV-2 PCR-negative and PCR-positive groups. A decision tree analysis classification resulted in a sensitivity of 83% and specificity of 86%, but limited robustness to dataset changes. Modest values for the sensitivity (74%) and specificity (52%) were obtained using linear discriminant analysis. A systematic search for peaks led to a sensitivity of 77% and specificity of 67%; however, validation by transferability to other data is questionable. CONCLUSIONS Despite identifying several peaks by MCC-IMS with significant differences in peak intensity between PCR-negative and PCR-positive samples, finding a classification system that allows reliable differentiation between the two groups proved to be difficult. However, with some modifications to the setup, breath gas analysis using MCC-IMS may be a useful diagnostic toolbox for SARS-CoV-2 infection. TRIAL REGISTRATION This study was registered at ClinicalTrials.gov on September 21, 2020 (NCT04556318; Study-ID: HC-N-H-2004).
Collapse
Affiliation(s)
- Florian Voit
- Department of Internal Medicine II, University Hospital Rechts Der Isar, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.
| | - J Erber
- Department of Internal Medicine II, University Hospital Rechts Der Isar, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - M Feuerherd
- Institute of Virology, Helmholtz Center Munich, TUM, School of Medicine, Munich, Germany
- Division of Gastroenterology, Massachusetts General Hospital and Harvard Medical School, Boston, USA
| | - H Fries
- B. Braun Melsungen AG, Melsungen, Germany
| | - N Bitterlich
- ABX-CRO Advanced Pharmaceutical Services Forschungsgesellschaft mbH, Dresden, Germany
| | - E Diehl-Wiesenecker
- Department of Emergency Medicine, Charité-Universitätsmedizin Berlin, Freie Universität Berlin and Humboldt-Universität Zu Berlin, Berlin, Germany
| | - S Gladis
- Department of Internal Medicine II, University Hospital Rechts Der Isar, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - J Lieb
- Department of Internal Medicine II, University Hospital Rechts Der Isar, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - U Protzer
- Institute of Virology, Helmholtz Center Munich, TUM, School of Medicine, Munich, Germany
- German Center for Infection Research (DZIF), Munich Partner Site, Munich, Germany
| | - J Schneider
- Department of Internal Medicine II, University Hospital Rechts Der Isar, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - F Geisler
- Department of Internal Medicine II, University Hospital Rechts Der Isar, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - R Somasundaram
- Department of Emergency Medicine, Charité-Universitätsmedizin Berlin, Freie Universität Berlin and Humboldt-Universität Zu Berlin, Berlin, Germany
| | - R M Schmid
- Department of Internal Medicine II, University Hospital Rechts Der Isar, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - W Bauer
- Department of Emergency Medicine, Charité-Universitätsmedizin Berlin, Freie Universität Berlin and Humboldt-Universität Zu Berlin, Berlin, Germany
| | - C D Spinner
- Department of Internal Medicine II, University Hospital Rechts Der Isar, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
- German Center for Infection Research (DZIF), Munich Partner Site, Munich, Germany
| |
Collapse
|
21
|
Shen Q, Fang C, Serpe MJ. Microgel-based etalon immunoassay for IgG detection. Anal Bioanal Chem 2023; 415:5645-5656. [PMID: 37421438 DOI: 10.1007/s00216-023-04834-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 06/26/2023] [Accepted: 06/29/2023] [Indexed: 07/10/2023]
Abstract
We developed an immunoassay for mouse immunoglobulin (IgG) quantitation using poly(N-isopropylacrylamide-co-acrylic acid) (pNIPAm-co-AAc) microgel-based etalon devices. To achieve this, a biotinylated primary antibody specific to mouse IgG was immobilized on the top Au layer of an etalon device via its interaction with a streptavidin-modified etalon surface. Mouse IgG captured on the etalon surface from the solution was quantified using an HRP-conjugated secondary antibody. HRP catalyzed the oxidation of 4-chloro-1-naphthol (4CN) to form insoluble 4-chloro-1-naphthon (4CNP), resulting in a concentration change of 4CN in solution. The etalon was able to detect the 4CN concentration change by monitoring the extent of the etalon's reflectance peak shift, which allows the quantitation of mouse IgG. The etalon-based assay can detect mouse IgG down to 0.018 nM with a linear range of 0.02-5 nM.
Collapse
Affiliation(s)
- Qiming Shen
- Department of Chemistry, University of Alberta, Edmonton, Alberta, T6G 2G2, Canada
| | - Changhao Fang
- Department of Chemistry, University of Alberta, Edmonton, Alberta, T6G 2G2, Canada
| | - Michael J Serpe
- Department of Chemistry, University of Alberta, Edmonton, Alberta, T6G 2G2, Canada.
| |
Collapse
|
22
|
Gao S, Rui X, Zeng X, Zhou J. EWOD Chip with Micro-Barrier Electrode for Simultaneous Enhanced Mixing during Transportation. SENSORS (BASEL, SWITZERLAND) 2023; 23:7102. [PMID: 37631640 PMCID: PMC10459807 DOI: 10.3390/s23167102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 08/03/2023] [Accepted: 08/10/2023] [Indexed: 08/27/2023]
Abstract
Digital microfluidic platforms have been extensively studied in biology. However, achieving efficient mixing of macromolecules in microscale, low Reynolds number fluids remains a major challenge. To address this challenge, this study presents a novel design solution based on dielectric electro-wetting (EWOD) by optimizing the geometry of the transport electrode. The new design integrates micro-barriers on the electrodes to generate vortex currents that promote mixing during droplet transport. This design solution requires only two activation signals, minimizing the number of pins required. The mixing performance of the new design was evaluated by analyzing the degree of mixing inside the droplet and quantifying the motion of the internal particles. In addition, the rapid mixing capability of the new platform was demonstrated by successfully mixing the sorbitol solution with the detection solution and detecting the resulting reaction products. The experimental results show that the transfer electrode with a micro-barrier enables rapid mixing of liquids with a six-fold increase in mixing efficiency, making it ideal for the development of EWOD devices.
Collapse
Affiliation(s)
- Shang Gao
- School of Microelectronics, Fudan University, Shanghai 200433, China; (S.G.); (X.R.)
| | - Xichuan Rui
- School of Microelectronics, Fudan University, Shanghai 200433, China; (S.G.); (X.R.)
- Department of Micro/Nano Electronics State Key Laboratory of Radio Frequency Heterogeneous Integration, Shanghai Jiao Tong University, Shanghai 200433, China
| | - Xiangyu Zeng
- School of Microelectronics, Fudan University, Shanghai 200433, China; (S.G.); (X.R.)
| | - Jia Zhou
- School of Microelectronics, Fudan University, Shanghai 200433, China; (S.G.); (X.R.)
| |
Collapse
|
23
|
Pillai S, Kwan JC, Yaziji F, Yu H, Tran SD. Mapping the Potential of Microfluidics in Early Diagnosis and Personalized Treatment of Head and Neck Cancers. Cancers (Basel) 2023; 15:3894. [PMID: 37568710 PMCID: PMC10417175 DOI: 10.3390/cancers15153894] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 07/24/2023] [Accepted: 07/27/2023] [Indexed: 08/13/2023] Open
Abstract
Head and neck cancers (HNCs) account for ~4% of all cancers in North America and encompass cancers affecting the oral cavity, pharynx, larynx, sinuses, nasal cavity, and salivary glands. The anatomical complexity of the head and neck region, characterized by highly perfused and innervated structures, presents challenges in the early diagnosis and treatment of these cancers. The utilization of sub-microliter volumes and the unique phenomenon associated with microscale fluid dynamics have facilitated the development of microfluidic platforms for studying complex biological systems. The advent of on-chip microfluidics has significantly impacted the diagnosis and treatment strategies of HNC. Sensor-based microfluidics and point-of-care devices have improved the detection and monitoring of cancer biomarkers using biological specimens like saliva, urine, blood, and serum. Additionally, tumor-on-a-chip platforms have allowed the creation of patient-specific cancer models on a chip, enabling the development of personalized treatments through high-throughput screening of drugs. In this review, we first focus on how microfluidics enable the development of an enhanced, functional drug screening process for targeted treatment in HNCs. We then discuss current advances in microfluidic platforms for biomarker sensing and early detection, followed by on-chip modeling of HNC to evaluate treatment response. Finally, we address the practical challenges that hinder the clinical translation of these microfluidic advances.
Collapse
Affiliation(s)
| | | | | | | | - Simon D. Tran
- McGill Craniofacial Tissue Engineering and Stem Cell Laboratory, Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal, QC H3A 0C7, Canada; (S.P.); (J.C.K.); (F.Y.); (H.Y.)
| |
Collapse
|
24
|
Pusterla N, Naranatt P, Swadia H, Winfield L, Hartwig A, Barnum S, Mendonsa E. Multi-Centered Field Evaluation of a Salmonella spp. Point-of-Care PCR Assay Using Equine Feces and Environmental Samples. J Equine Vet Sci 2023; 126:104538. [PMID: 37150233 DOI: 10.1016/j.jevs.2023.104538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 04/28/2023] [Accepted: 05/02/2023] [Indexed: 05/09/2023]
Abstract
The introduction of microfluidic card technology has opened the field for rapid point-of-care (POC) molecular assays, including fecal and environmental Salmonella spp. testing. The purpose of this study was to evaluate a novel POC PCR assay for the detection of Salmonella spp. in feces and environmental samples. A total of 143 fecal samples and 132 environmental samples were collected for POC PCR Salmonella spp. testing as well as qPCR testing. Each sample was inoculated into selenite broth and incubated for 18 to 24 hours. For the POC PCR assay, 14 μl of selenite broth were mixed with 126 μl of PCR reaction mix and pipetted into a microfluidic test card targeting the invA and ttrC gene of Salmonella enterica. For qPCR analysis, 200 µl of the selenite broth were processed for DNA purification and Salmonella spp. testing targeting the invA gene. The overall agreement between the POC PCR Salmonella spp. assay and qPCR assay was 88.1% for feces and 97.0% for environmental samples. Strong agreement and short turn-around-time make the POC device the first molecular diagnostic platform allowing detection of Salmonella spp. in a hospital setting without having to ship out samples to a veterinary diagnostic laboratory. The availability of an accurate POC PCR assay for the detection of Salmonella spp. will enhance the diagnostic capability of equine veterinarians to timely support a diagnosis of salmonellosis and also monitor the environment in order to reduce the risk of nosocomial infections.
Collapse
Affiliation(s)
- Nicola Pusterla
- Department of Medicine and Epidemiology, School of Veterinary Medicine, University of California, Davis, CA.
| | | | | | | | | | - Samantha Barnum
- Department of Medicine and Epidemiology, School of Veterinary Medicine, University of California, Davis, CA
| | | |
Collapse
|
25
|
Dorta-Gorrín A, Navas-Méndez J, Gozalo-Margüello M, Miralles L, García-Hevia L. Detection of SARS-CoV-2 Based on Nucleic Acid Amplification Tests (NAATs) and Its Integration into Nanomedicine and Microfluidic Devices as Point-of-Care Testing (POCT). Int J Mol Sci 2023; 24:10233. [PMID: 37373381 DOI: 10.3390/ijms241210233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 06/10/2023] [Accepted: 06/14/2023] [Indexed: 06/29/2023] Open
Abstract
The coronavirus SARS-CoV-2 has highlighted the criticality of an accurate and rapid diagnosis in order to contain the spread of the virus. Knowledge of the viral structure and its genome is essential for diagnosis development. The virus is still quickly evolving and the global scenario could easily change. Thus, a greater range of diagnostic options is essential to face this threat to public health. In response to the global demand, there has been a rapid advancement in the understanding of current diagnostic methods. In fact, innovative approaches have emerged, leveraging the benefits of nanomedicine and microfluidic technologies. Although this development has been incredibly fast, several key areas require further investigation and optimization, such as sample collection and preparation, assay optimization and sensitivity, cost effectiveness, scalability device miniaturization, and portability and integration with smartphones. Addressing these gaps in the knowledge and these technological challenges will contribute to the development of reliable, sensitive, and user-friendly NAAT-based POCTs for the diagnosis of SARS-CoV-2 and other infectious diseases, facilitating rapid and effective patient management. This review aims to provide an overview of current SARS-CoV-2 detection methods based on nucleic acid detection tests (NAATs). Additionally, it explores promising approaches that combine nanomedicine and microfluidic devices with high sensitivity and relatively fast 'time to answer' for integration into point-of-care testing (POCT).
Collapse
Affiliation(s)
- Alexis Dorta-Gorrín
- Department of Molecular Biology, Faculty of Medicine, University of Cantabria (UC), 39011 Santander, Spain
- Instituto de Investigación Valdecilla (IDIVAL), 39011 Santander, Spain
- Environmental Genetics Department, Ecohydros S.L., 39600 Maliaño, Spain
| | - Jesús Navas-Méndez
- Department of Molecular Biology, Faculty of Medicine, University of Cantabria (UC), 39011 Santander, Spain
- Instituto de Investigación Valdecilla (IDIVAL), 39011 Santander, Spain
| | - Mónica Gozalo-Margüello
- Instituto de Investigación Valdecilla (IDIVAL), 39011 Santander, Spain
- Microbiology Service of University Hospital Marqués de Valdecilla (HUMV), 39008 Santander, Spain
- CIBER de Enfermedades Infecciosas-CIBERINFEC (CB21/13/00068), Instituto de Salud Carlos III, 28029 Madrid, Spain
| | - Laura Miralles
- Environmental Genetics Department, Ecohydros S.L., 39600 Maliaño, Spain
- Department of Functional Biology, Area of Genetics, Faculty of Medicine, University of Oviedo, 33006 Oviedo, Spain
| | - Lorena García-Hevia
- Department of Molecular Biology, Faculty of Medicine, University of Cantabria (UC), 39011 Santander, Spain
- Instituto de Investigación Valdecilla (IDIVAL), 39011 Santander, Spain
| |
Collapse
|
26
|
Luttikhuis N, Wiebe KS. Analyzing SDG interlinkages: identifying trade-offs and synergies for a responsible innovation. SUSTAINABILITY SCIENCE 2023; 18:1-19. [PMID: 37363308 PMCID: PMC10214325 DOI: 10.1007/s11625-023-01336-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Accepted: 04/17/2023] [Indexed: 06/28/2023]
Abstract
This paper responds to recent calls to address the indivisible nature of the Sustainable Development Goal (SDG) framework and the related knowledge gap on how SDG targets interlink with each other. It examines how SDG targets interact in the context of a specific technology, point of care (PoC) microfluidics, and how this relates to the concept of responsible innovation (RI). The novel SDG interlinkages methodology developed here involves several steps to filter the relevant interlinkages and a focus group of experts for discussing these interlinkages. The main findings indicate that several social synergies occur when deploying PoC microfluidics, but that the environmental trade-offs may jeopardize the total progress toward the SDGs. More specifically, the environmental sacrifices (use of plastics and lack of recyclability) resulted in the product being cheaper and, thus, better accessible. This work suggests that attention should be given (and prioritized) to the use of renewable and recyclable materials without jeopardizing the accessibility of the product. This should minimize the identified trade-offs. These findings inform how analyzing SDG interlinkages relates to the responsibilities and dimensions of RI in several ways. First, analyzing SDG interlinkages helps to execute the governance responsibility by using the RI dimensions (anticipation, reflexivity, inclusion and responsiveness). Second, analyzing SDG interlinkages gives insights into if and how a technology relates to the do-good and avoid-harm responsibility. This is important to assess the responsiveness of the technology to ensure that the technology can become truly sustainable and leaves no one behind.
Collapse
Affiliation(s)
- Nikki Luttikhuis
- Sustainable Energy Technology, SINTEF, Torgarden, P.O. Box 4760, 7465 Trondheim, Norway
- Department of Industrial Economics and Technology Management, Norwegian University of Science and Technology (NTNU), 7491 Trondheim, Norway
| | - Kirsten S. Wiebe
- Sustainable Energy Technology, SINTEF, Torgarden, P.O. Box 4760, 7465 Trondheim, Norway
| |
Collapse
|
27
|
Sokolov P, Samokhvalov P, Sukhanova A, Nabiev I. Biosensors Based on Inorganic Composite Fluorescent Hydrogels. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:nano13111748. [PMID: 37299650 DOI: 10.3390/nano13111748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 05/23/2023] [Accepted: 05/25/2023] [Indexed: 06/12/2023]
Abstract
Fluorescent hydrogels are promising candidate materials for portable biosensors to be used in point-of-care diagnosis because (1) they have a greater capacity for binding organic molecules than immunochromatographic test systems, determined by the immobilization of affinity labels within the three-dimensional hydrogel structure; (2) fluorescent detection is more sensitive than the colorimetric detection of gold nanoparticles or stained latex microparticles; (3) the properties of the gel matrix can be finely tuned for better compatibility and detection of different analytes; and (4) hydrogel biosensors can be made to be reusable and suitable for studying dynamic processes in real time. Water-soluble fluorescent nanocrystals are widely used for in vitro and in vivo biological imaging due to their unique optical properties, and hydrogels based on these allow the preservation of these properties in bulk composite macrostructures. Here we review the techniques for obtaining analyte-sensitive fluorescent hydrogels based on nanocrystals, the main methods used for detecting the fluorescent signal changes, and the approaches to the formation of inorganic fluorescent hydrogels via sol-gel phase transition using surface ligands of the nanocrystals.
Collapse
Affiliation(s)
- Pavel Sokolov
- Life Improvement by Future Technologies (LIFT) Center, Skolkovo, 143025 Moscow, Russia
- Laboratory of Nano-Bioengineering, National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), 115522 Moscow, Russia
| | - Pavel Samokhvalov
- Life Improvement by Future Technologies (LIFT) Center, Skolkovo, 143025 Moscow, Russia
- Laboratory of Nano-Bioengineering, National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), 115522 Moscow, Russia
| | - Alyona Sukhanova
- Laboratoire de Recherche en Nanosciences, LRN-EA4682, Université de Reims Champagne-Ardenne, 51100 Reims, France
| | - Igor Nabiev
- Life Improvement by Future Technologies (LIFT) Center, Skolkovo, 143025 Moscow, Russia
- Laboratory of Nano-Bioengineering, National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), 115522 Moscow, Russia
- Laboratoire de Recherche en Nanosciences, LRN-EA4682, Université de Reims Champagne-Ardenne, 51100 Reims, France
| |
Collapse
|
28
|
Bălan AM, Bodolea C, Trancă SD, Hagău N. Trends in Molecular Diagnosis of Nosocomial Pneumonia Classic PCR vs. Point-of-Care PCR: A Narrative Review. Healthcare (Basel) 2023; 11:healthcare11091345. [PMID: 37174887 PMCID: PMC10177880 DOI: 10.3390/healthcare11091345] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 04/23/2023] [Accepted: 05/05/2023] [Indexed: 05/15/2023] Open
Abstract
Nosocomial pneumonia is one of the most frequent hospital-acquired infections. One of the types of nosocomial pneumonia is ventilator-associated pneumonia, which occurs in endotracheally intubated patients in intensive care units (ICU). Ventilator-associated pneumonia may be caused by multidrug-resistant pathogens, which increase the risk of complications due to the difficulty in treating them. Pneumonia is a respiratory disease that requires targeted antimicrobial treatment initiated as early as possible to have a good outcome. For the therapy to be as specific and started sooner, diagnostic methods have evolved rapidly, becoming quicker and simpler to perform. Polymerase chain reaction (PCR) is a rapid diagnostic technique with numerous advantages compared to classic plate culture-based techniques. Researchers continue to improve diagnostic methods; thus, the newest types of PCR can be performed at the bedside, in the ICU, so-called point of care testing-PCR (POC-PCR). The purpose of this review is to highlight the benefits and drawbacks of PCR-based techniques in managing nosocomial pneumonia.
Collapse
Affiliation(s)
- Andrei-Mihai Bălan
- Department of Anaesthesia and Intensive Care 2, "Iuliu Hatieganu", University of Medicine and Pharmacy Cluj-Napoca, 400012 Cluj-Napoca, Romania
- Department of Anaesthesia and Intensive Care, Municipal Clinical Hospital, 400139 Cluj-Napoca, Romania
| | - Constantin Bodolea
- Department of Anaesthesia and Intensive Care 2, "Iuliu Hatieganu", University of Medicine and Pharmacy Cluj-Napoca, 400012 Cluj-Napoca, Romania
- Department of Anaesthesia and Intensive Care, Municipal Clinical Hospital, 400139 Cluj-Napoca, Romania
| | - Sebastian Daniel Trancă
- Department of Anaesthesia and Intensive Care 2, "Iuliu Hatieganu", University of Medicine and Pharmacy Cluj-Napoca, 400012 Cluj-Napoca, Romania
- Emergency Department, The Emergency County Hospital Cluj, 400347 Cluj-Napoca, Romania
| | - Natalia Hagău
- Department of Anaesthesia and Intensive Care 2, "Iuliu Hatieganu", University of Medicine and Pharmacy Cluj-Napoca, 400012 Cluj-Napoca, Romania
- Department of Anaesthesia and Intensive Care, "Regina Maria" Hospital, 400221 Cluj-Napoca, Romania
| |
Collapse
|
29
|
Ahmad NN, Ghazali NNN, Abdul Rani AT, Othman MH, Kee CC, Jiwanti PK, Rodríguez-Gómez A, Wong YH. Finger-Actuated Micropump of Constant Flow Rate without Backflow. MICROMACHINES 2023; 14:881. [PMID: 37421113 DOI: 10.3390/mi14040881] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2023] [Revised: 04/15/2023] [Accepted: 04/16/2023] [Indexed: 07/09/2023]
Abstract
This paper presents a finger-actuated micropump with a consistent flow rate and no backflow. The fluid dynamics in interstitial fluid (ISF) extraction microfluidics are studied through analytical, simulation, and experimental methods. Head losses, pressure drop, diodocity, hydrogel swelling, criteria for hydrogel absorption, and consistency flow rate are examined in order to access microfluidic performance. In terms of consistency, the experimental result revealed that after 20 s of duty cycles with full deformation on the flexible diaphragm, the output pressure became uniform and the flow rate remained at nearly constant levels of 2.2 μL/min. The flow rate discrepancy between the experimental and predicted flow rates is around 22%. In terms of diodicity, when the serpentine microchannel and hydrogel-assisted reservoir are added to the microfluidic system integration, the diodicity increases by 2% (Di = 1.48) and 34% (Di = 1.96), respectively, compared to when the Tesla integration (Di = 1.45) is used alone. A visual and experimentally weighted analysis finds no signs of backflow. These significant flow characteristics demonstrate their potential usage in many low-cost and portable microfluidic applications.
Collapse
Affiliation(s)
- NurFarrahain Nadia Ahmad
- Department of Mechanical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Federal Territory, Malaysia
- School of Mechanical Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia
| | - Nik Nazri Nik Ghazali
- Department of Mechanical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Federal Territory, Malaysia
| | - Ahmad Taufiq Abdul Rani
- Industrial and Mechanical Design, Faculty of Engineering, German-Malaysian Institute, Jalan Ilmiah, Taman Universiti, Kajang 43000, Selangor, Malaysia
| | - Mohammad Hafiz Othman
- Department of Process & Food Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia
| | - Chia Ching Kee
- Centre for Advance Materials and Intelligent Manufacturing, Faculty of Engineering, Built Environment & Information Technology, SEGi University, Petaling Jaya 47810, Selangor, Malaysia
| | - Prastika Krisma Jiwanti
- Nanotechnology Engineering, Faculty of Advanced Technology and Multidiscipline, Universitas Airlangga, Surabaya 60115, Indonesia
| | - Arturo Rodríguez-Gómez
- Instituto de Física, Universidad Nacional Autónoma de México, Circuito de la Investigación Científica s/n, Ciudad Universitaria, A.P. 20-364, Coyoacán, Ciudad de México 04510, Mexico
| | - Yew Hoong Wong
- Department of Mechanical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Federal Territory, Malaysia
| |
Collapse
|
30
|
Scarsi A, Pedone D, Pompa PP. A multi-line platinum nanozyme-based lateral flow device for the colorimetric evaluation of total antioxidant capacity in different matrices. NANOSCALE ADVANCES 2023; 5:2167-2174. [PMID: 37056622 PMCID: PMC10089119 DOI: 10.1039/d2na00931e] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 02/06/2023] [Indexed: 06/19/2023]
Abstract
The evaluation of Total Antioxidant Capacity (TAC), namely the complete pattern of antioxidant species in a complex medium, is of major interest in many fields ranging from health monitoring to quality control in the food industry. In this framework, point-of-care (POC) testing technologies are a promising diagnostic solution for rapid on-site analyses, unlike laboratory based-assays, which are often limited by centralized analyses, time-consuming and costly procedures, and invasiveness in the case of health diagnostics. In this work, we developed a POC methodology that evaluates TAC in different matrices, exploiting the peroxidase-like properties of 5 nm platinum nanoparticles (PtNPs), combined with a colorimetric paper-based device. Notably, we designed and optimized a multi-line PtNPs-based Lateral Flow Assay (LFA), which relies on three sequential test lines with increasing concentrations of platinum nanozymes, to get a non-invasive, accurate, and fast (10 minutes) colorimetric evaluation of the body TAC in saliva samples. Furthermore, we employed the device as a prototype of a quality control tool in the food industry, for the determination of the TAC in fruit juices.
Collapse
Affiliation(s)
- Anna Scarsi
- Nanobiointeractions & Nanodiagnostics, Istituto Italiano di Tecnologia (IIT) Via Morego 30 16163-Genova Italy
- Department of Chemistry and Industrial Chemistry, University of Genova Via Dodecaneso 31 16146-Genova Italy
| | - Deborah Pedone
- Nanobiointeractions & Nanodiagnostics, Istituto Italiano di Tecnologia (IIT) Via Morego 30 16163-Genova Italy
| | - Pier Paolo Pompa
- Nanobiointeractions & Nanodiagnostics, Istituto Italiano di Tecnologia (IIT) Via Morego 30 16163-Genova Italy
| |
Collapse
|
31
|
Thwala LN, Ndlovu SC, Mpofu KT, Lugongolo MY, Mthunzi-Kufa P. Nanotechnology-Based Diagnostics for Diseases Prevalent in Developing Countries: Current Advances in Point-of-Care Tests. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:1247. [PMID: 37049340 PMCID: PMC10096522 DOI: 10.3390/nano13071247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 03/24/2023] [Accepted: 03/27/2023] [Indexed: 06/19/2023]
Abstract
The introduction of point-of-care testing (POCT) has revolutionized medical testing by allowing for simple tests to be conducted near the patient's care point, rather than being confined to a medical laboratory. This has been especially beneficial for developing countries with limited infrastructure, where testing often involves sending specimens off-site and waiting for hours or days for results. However, the development of POCT devices has been challenging, with simplicity, accuracy, and cost-effectiveness being key factors in making these tests feasible. Nanotechnology has played a crucial role in achieving this goal, by not only making the tests possible but also masking their complexity. In this article, recent developments in POCT devices that benefit from nanotechnology are discussed. Microfluidics and lab-on-a-chip technologies are highlighted as major drivers of point-of-care testing, particularly in infectious disease diagnosis. These technologies enable various bioassays to be used at the point of care. The article also addresses the challenges faced by these technological advances and interesting future trends. The benefits of point-of-care testing are significant, especially in developing countries where medical care is shifting towards prevention, early detection, and managing chronic conditions. Infectious disease tests at the point of care in low-income countries can lead to prompt treatment, preventing infections from spreading.
Collapse
Affiliation(s)
- Lungile Nomcebo Thwala
- National Laser Centre, Council for Scientific and Industrial Research, P.O. Box 395, Pretoria 0001, South Africa
| | - Sphumelele Colin Ndlovu
- National Laser Centre, Council for Scientific and Industrial Research, P.O. Box 395, Pretoria 0001, South Africa
| | - Kelvin Tafadzwa Mpofu
- National Laser Centre, Council for Scientific and Industrial Research, P.O. Box 395, Pretoria 0001, South Africa
| | - Masixole Yvonne Lugongolo
- National Laser Centre, Council for Scientific and Industrial Research, P.O. Box 395, Pretoria 0001, South Africa
| | - Patience Mthunzi-Kufa
- National Laser Centre, Council for Scientific and Industrial Research, P.O. Box 395, Pretoria 0001, South Africa
- College of Agriculture, Engineering and Science, School of Chemistry and Physics, University of Kwa-Zulu Natal, University Road, Westville, Durban 3630, South Africa
| |
Collapse
|
32
|
García-Hernández LA, Martínez-Martínez E, Pazos-Solís D, Aguado-Preciado J, Dutt A, Chávez-Ramírez AU, Korgel B, Sharma A, Oza G. Optical Detection of Cancer Cells Using Lab-on-a-Chip. BIOSENSORS 2023; 13:bios13040439. [PMID: 37185514 PMCID: PMC10136345 DOI: 10.3390/bios13040439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/23/2023] [Accepted: 03/28/2023] [Indexed: 05/17/2023]
Abstract
The global need for accurate and efficient cancer cell detection in biomedicine and clinical diagnosis has driven extensive research and technological development in the field. Precision, high-throughput, non-invasive separation, detection, and classification of individual cells are critical requirements for successful technology. Lab-on-a-chip devices offer enormous potential for solving biological and medical problems and have become a priority research area for microanalysis and manipulating cells. This paper reviews recent developments in the detection of cancer cells using the microfluidics-based lab-on-a-chip method, focusing on describing and explaining techniques that use optical phenomena and a plethora of probes for sensing, amplification, and immobilization. The paper describes how optics are applied in each experimental method, highlighting their advantages and disadvantages. The discussion includes a summary of current challenges and prospects for cancer diagnosis.
Collapse
Affiliation(s)
- Luis Abraham García-Hernández
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Parque Tecnológico Querétaro, Pedro Escobedo, Querétaro C.P. 76703, Mexico
| | | | - Denni Pazos-Solís
- Tecnologico de Monterrey, School of Engineering and Sciences, Centre of Bioengineering, Campus Queretaro, Querétaro C.P. 76130, Mexico
| | - Javier Aguado-Preciado
- Tecnologico de Monterrey, School of Engineering and Sciences, Centre of Bioengineering, Campus Queretaro, Querétaro C.P. 76130, Mexico
| | - Ateet Dutt
- Instituto de Investigaciones en Materiales, Circuito Exterior S/N Ciudad Universitaria, Mexico City C.P. 04510, Mexico
| | - Abraham Ulises Chávez-Ramírez
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Parque Tecnológico Querétaro, Pedro Escobedo, Querétaro C.P. 76703, Mexico
| | - Brian Korgel
- McKetta Department of Chemical Engineering and Texas Materials Institute, The University of Texas at Austin, Austin, TX 78712-1062, USA
| | - Ashutosh Sharma
- Tecnologico de Monterrey, School of Engineering and Sciences, Centre of Bioengineering, Campus Queretaro, Querétaro C.P. 76130, Mexico
| | - Goldie Oza
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Parque Tecnológico Querétaro, Pedro Escobedo, Querétaro C.P. 76703, Mexico
| |
Collapse
|
33
|
Chen F, Hu Q, Li H, Xie Y, Xiu L, Zhang Y, Guo X, Yin K. Multiplex Detection of Infectious Diseases on Microfluidic Platforms. BIOSENSORS 2023; 13:bios13030410. [PMID: 36979622 PMCID: PMC10046538 DOI: 10.3390/bios13030410] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/15/2023] [Accepted: 03/20/2023] [Indexed: 05/31/2023]
Abstract
Infectious diseases contribute significantly to the global disease burden. Sensitive and accurate screening methods are some of the most effective means of identifying sources of infection and controlling infectivity. Conventional detecting strategies such as quantitative polymerase chain reaction (qPCR), DNA sequencing, and mass spectrometry typically require bulky equipment and well-trained personnel. Therefore, mass screening of a large population using conventional strategies during pandemic periods often requires additional manpower, resources, and time, which cannot be guaranteed in resource-limited settings. Recently, emerging microfluidic technologies have shown the potential to replace conventional methods in performing point-of-care detection because they are automated, miniaturized, and integrated. By exploiting the spatial separation of detection sites, microfluidic platforms can enable the multiplex detection of infectious diseases to reduce the possibility of misdiagnosis and incomplete diagnosis of infectious diseases with similar symptoms. This review presents the recent advances in microfluidic platforms used for multiplex detection of infectious diseases, including microfluidic immunosensors and microfluidic nucleic acid sensors. As representative microfluidic platforms, lateral flow immunoassay (LFIA) platforms, polymer-based chips, paper-based devices, and droplet-based devices will be discussed in detail. In addition, the current challenges, commercialization, and prospects are proposed to promote the application of microfluidic platforms in infectious disease detection.
Collapse
Affiliation(s)
- Fumin Chen
- School of Global Health, Chinese Center for Tropical Diseases Research, Shanghai Jiao Tong University School of Medicine, No. 227 Chongqing South Road, Shanghai 200025, China
- One Health Center, Shanghai Jiao Tong University—The University of Edinburgh, Shanghai 200025, China
| | - Qinqin Hu
- School of Global Health, Chinese Center for Tropical Diseases Research, Shanghai Jiao Tong University School of Medicine, No. 227 Chongqing South Road, Shanghai 200025, China
- One Health Center, Shanghai Jiao Tong University—The University of Edinburgh, Shanghai 200025, China
| | - Huimin Li
- School of Global Health, Chinese Center for Tropical Diseases Research, Shanghai Jiao Tong University School of Medicine, No. 227 Chongqing South Road, Shanghai 200025, China
- One Health Center, Shanghai Jiao Tong University—The University of Edinburgh, Shanghai 200025, China
| | - Yi Xie
- School of Global Health, Chinese Center for Tropical Diseases Research, Shanghai Jiao Tong University School of Medicine, No. 227 Chongqing South Road, Shanghai 200025, China
- One Health Center, Shanghai Jiao Tong University—The University of Edinburgh, Shanghai 200025, China
| | - Leshan Xiu
- School of Global Health, Chinese Center for Tropical Diseases Research, Shanghai Jiao Tong University School of Medicine, No. 227 Chongqing South Road, Shanghai 200025, China
- One Health Center, Shanghai Jiao Tong University—The University of Edinburgh, Shanghai 200025, China
| | - Yuqian Zhang
- Department of Surgery, Division of Surgery Research, Mayo Clinic, Rochester, MN 55905, USA
- Microbiome Program, Center for Individualized Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Xiaokui Guo
- School of Global Health, Chinese Center for Tropical Diseases Research, Shanghai Jiao Tong University School of Medicine, No. 227 Chongqing South Road, Shanghai 200025, China
- One Health Center, Shanghai Jiao Tong University—The University of Edinburgh, Shanghai 200025, China
| | - Kun Yin
- School of Global Health, Chinese Center for Tropical Diseases Research, Shanghai Jiao Tong University School of Medicine, No. 227 Chongqing South Road, Shanghai 200025, China
- One Health Center, Shanghai Jiao Tong University—The University of Edinburgh, Shanghai 200025, China
| |
Collapse
|
34
|
Liu L, Ma W, Wang X, Li S. Recent Progress of Surface-Enhanced Raman Spectroscopy for Bacteria Detection. BIOSENSORS 2023; 13:350. [PMID: 36979564 PMCID: PMC10046079 DOI: 10.3390/bios13030350] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 02/28/2023] [Accepted: 02/28/2023] [Indexed: 06/18/2023]
Abstract
There are various pathogenic bacteria in the surrounding living environment, which not only pose a great threat to human health but also bring huge losses to economic development. Conventional methods for bacteria detection are usually time-consuming, complicated and labor-intensive, and cannot meet the growing demands for on-site and rapid analyses. Sensitive, rapid and effective methods for pathogenic bacteria detection are necessary for environmental monitoring, food safety and infectious bacteria diagnosis. Recently, benefiting from its advantages of rapidity and high sensitivity, surface-enhanced Raman spectroscopy (SERS) has attracted significant attention in the field of bacteria detection and identification as well as drug susceptibility testing. Here, we comprehensively reviewed the latest advances in SERS technology in the field of bacteria analysis. Firstly, the mechanism of SERS detection and the fabrication of the SERS substrate were briefly introduced. Secondly, the label-free SERS applied for the identification of bacteria species was summarized in detail. Thirdly, various SERS tags for the high-sensitivity detection of bacteria were also discussed. Moreover, we emphasized the application prospects of microfluidic SERS chips in antimicrobial susceptibility testing (AST). In the end, we gave an outlook on the future development and trends of SERS in point-of-care diagnoses of bacterial infections.
Collapse
Affiliation(s)
- Lulu Liu
- College of Chemistry and Chemical Engineering, Chongqing University of Science and Technology, Chongqing 401331, China
| | - Wenrui Ma
- Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China
- Key Disciplines Laboratory of Novel Micro-Nano Devices and System Technology, College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China
| | - Xiang Wang
- Department of Mechanical Engineering, Dongguan University of Technology, Dongguan 523808, China
| | - Shunbo Li
- Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China
- Key Disciplines Laboratory of Novel Micro-Nano Devices and System Technology, College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China
| |
Collapse
|
35
|
Clemente F, Antonacci A, Giardi MT, Frisulli V, Tambaro FP, Scognamiglio V. Last Trends in Point-of-Care (POC) Diagnostics for the Management of Hematological Indices in Home Care Patients. BIOSENSORS 2023; 13:345. [PMID: 36979557 PMCID: PMC10046198 DOI: 10.3390/bios13030345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 02/28/2023] [Accepted: 03/01/2023] [Indexed: 06/18/2023]
Abstract
Today, complete blood count (CBC) analyses are highly automated and allow for high throughput and accurate and reliable results. However, new analytical tools are in great demand to provide simple, rapid and cost-effective management of hematological indices in home care patients. Chronic disease monitoring at home has become a benefit for patients who are finding cost savings in programs designed to monitor/treat patients in offsite locations. This review reports the latest trends in point-of-care (POC) diagnostics useful for home testing of key hematological counts that may be affected during home therapy treatment.
Collapse
Affiliation(s)
- Fabrizio Clemente
- Department of Chemical Sciences and Materials Technologies, Institute of Crystallography (IC-CNR), Via Salaria Km 29.300, 00015 Monterotondo, Italy
- Institute of Crystallography (IC-CNR), Department of Chemical Sciences and Materials Technologies, URT Naples c/o Azienda Ospedialiera di Rilievo Nazionale (AORN) Santobono-Pausilipon Via Teresa Ravaschieri 8, 80112 Naples, Italy
| | - Amina Antonacci
- Department of Chemical Sciences and Materials Technologies, Institute of Crystallography (IC-CNR), Via Salaria Km 29.300, 00015 Monterotondo, Italy
| | - Maria Teresa Giardi
- Department of Chemical Sciences and Materials Technologies, Institute of Crystallography (IC-CNR), Via Salaria Km 29.300, 00015 Monterotondo, Italy
| | - Valeria Frisulli
- Department of Chemical Sciences and Materials Technologies, Institute of Crystallography (IC-CNR), Via Salaria Km 29.300, 00015 Monterotondo, Italy
| | - Francesco Paolo Tambaro
- Struttura Semplice Dipartimentale Trapianto di Midollo Osseo-Azienda Ospedialiera di Rilievo Nazionale (AORN), Santobono-Pausilipon, 80129 Napoli, Italy
| | - Viviana Scognamiglio
- Department of Chemical Sciences and Materials Technologies, Institute of Crystallography (IC-CNR), Via Salaria Km 29.300, 00015 Monterotondo, Italy
| |
Collapse
|
36
|
Chen L, Guo X, Sun X, Zhang S, Wu J, Yu H, Zhang T, Cheng W, Shi Y, Pan L. Porous Structural Microfluidic Device for Biomedical Diagnosis: A Review. MICROMACHINES 2023; 14:547. [PMID: 36984956 PMCID: PMC10051279 DOI: 10.3390/mi14030547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 02/21/2023] [Accepted: 02/22/2023] [Indexed: 06/18/2023]
Abstract
Microfluidics has recently received more and more attention in applications such as biomedical, chemical and medicine. With the development of microelectronics technology as well as material science in recent years, microfluidic devices have made great progress. Porous structures as a discontinuous medium in which the special flow phenomena of fluids lead to their potential and special applications in microfluidics offer a unique way to develop completely new microfluidic chips. In this article, we firstly introduce the fabrication methods for porous structures of different materials. Then, the physical effects of microfluid flow in porous media and their related physical models are discussed. Finally, the state-of-the-art porous microfluidic chips and their applications in biomedicine are summarized, and we present the current problems and future directions in this field.
Collapse
Affiliation(s)
| | | | - Xidi Sun
- Correspondence: (X.S.); (Y.S.); (L.P.)
| | | | | | | | | | | | - Yi Shi
- Correspondence: (X.S.); (Y.S.); (L.P.)
| | - Lijia Pan
- Correspondence: (X.S.); (Y.S.); (L.P.)
| |
Collapse
|
37
|
A Preliminary Experimental Study of Polydimethylsiloxane (PDMS)-To-PDMS Bonding Using Oxygen Plasma Treatment Incorporating Isopropyl Alcohol. Polymers (Basel) 2023; 15:polym15041006. [PMID: 36850290 PMCID: PMC9958961 DOI: 10.3390/polym15041006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 02/13/2023] [Accepted: 02/14/2023] [Indexed: 02/22/2023] Open
Abstract
Polydimethylsiloxane (PDMS) is a widely used material for soft lithography and microfabrication. PDMS exhibits some promising properties suitable for building microfluidic devices; however, bonding PDMS to PDMS and PDMS to other materials for multilayer structures in microfluidic devices is still challenging due to the hydrophobic nature of the surface of PDMS. This paper presents a simple yet effective method to increase the bonding strength for PDMS-to-PDMS using isopropyl alcohol (IPA). The experiment was carried out to evaluate the bonding strength for both the natural-cured and the heat-cured PDMS layer. The results show the effectiveness of our approach in terms of the improved irreversible bonding strength, up to 3.060 MPa, for the natural-cured PDMS and 1.373 MPa for the heat-cured PDMS, while the best bonding strength with the existing method in literature is 1.9 MPa. The work is preliminary because the underlying mechanism is only speculative and open for future research.
Collapse
|
38
|
Kiani MJ, Dehghan A, Saadatbakhsh M, Jamali Asl S, Nouri NM, Pishbin E. Robotic digital microfluidics: a droplet-based total analysis system. LAB ON A CHIP 2023; 23:748-760. [PMID: 36606624 DOI: 10.1039/d2lc00849a] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Developing automated platforms for point-of-need testing is a crucial global demand. Digital microfluidics is a promising solution for expanding integrated testing devices featuring ultimate control over the chemical and biological reactions in micro/nanoliter droplets. In this study, robotic digital microfluidics (RDMF) is introduced for the mechanical manipulation of the droplets precisely and inexpensively. A controllable and multifunctional arm equipped with several actuators is responsible for dispensing and manipulating droplets on a disposable superhydrophobic cartridge. The platform has been demonstrated with diverse functions, including droplet dispensing, transport, mixing, aliquoting, and splitting. Moreover, incorporating magnetic and heating modules into the system can realize particle manipulation and droplet heating. The liquid handling operations are investigated from both experimental and modeling perspectives. Handling a wide range of droplet sizes without needing high-voltage electric sources, integrability with different detection techniques, and ease of manufacturing are the main advantages of the RDMF platform compared to conventional digital microfluidic systems. The availability of a complete fluidic toolbox and multiple detection choices make RDMF promising for droplet-based total analysis technology. The system was applied for a urinalysis test to show its versatility in handling complex biochemical assays. The results entirely matched those obtained based on laboratory gold standard techniques.
Collapse
Affiliation(s)
- Mohammad Javad Kiani
- School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - Amin Dehghan
- School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
| | | | - Shahin Jamali Asl
- School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - Norouz Mohammad Nouri
- School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - Esmail Pishbin
- Bio-microfluidics Laboratory, Department of Electrical Engineering and Information Technology, Iranian Research Organization for Science and Technology (IROST), Tehran, Iran.
| |
Collapse
|
39
|
Stauss M, Htay H, Kooman JP, Lindsay T, Woywodt A. Wearables in Nephrology: Fanciful Gadgetry or Prêt-à-Porter? SENSORS (BASEL, SWITZERLAND) 2023; 23:1361. [PMID: 36772401 PMCID: PMC9919296 DOI: 10.3390/s23031361] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Revised: 01/20/2023] [Accepted: 01/24/2023] [Indexed: 06/18/2023]
Abstract
Telemedicine and digitalised healthcare have recently seen exponential growth, led, in part, by increasing efforts to improve patient flexibility and autonomy, as well as drivers from financial austerity and concerns over climate change. Nephrology is no exception, and daily innovations are underway to provide digitalised alternatives to current models of healthcare provision. Wearable technology already exists commercially, and advances in nanotechnology and miniaturisation mean interest is also garnering clinically. Here, we outline the current existing wearable technology pertaining to the diagnosis and monitoring of patients with a spectrum of kidney disease, give an overview of wearable dialysis technology, and explore wearables that do not yet exist but would be of great interest. Finally, we discuss challenges and potential pitfalls with utilising wearable technology and the factors associated with successful implementation.
Collapse
Affiliation(s)
- Madelena Stauss
- Department of Nephrology, Lancashire Teaching Hospitals NHS Foundation Trust, Preston PR2 9HT, UK
| | - Htay Htay
- Department of Renal Medicine, Singapore General Hospital, Singapore 169608, Singapore
| | - Jeroen P. Kooman
- Department of Internal Medicine, Division of Nephrology, Maastricht University, 6229 HX Maastricht, The Netherlands
| | - Thomas Lindsay
- Department of Nephrology, Lancashire Teaching Hospitals NHS Foundation Trust, Preston PR2 9HT, UK
| | - Alexander Woywodt
- Department of Nephrology, Lancashire Teaching Hospitals NHS Foundation Trust, Preston PR2 9HT, UK
| |
Collapse
|
40
|
Grootveld M, Page G, Bhogadia M, Hunwin K, Edgar M. Updates and Original Case Studies Focused on the NMR-Linked Metabolomics Analysis of Human Oral Fluids Part III: Implementations for the Diagnosis of Non-Cancerous Disorders, Both Oral and Systemic. Metabolites 2023; 13:metabo13010066. [PMID: 36676991 PMCID: PMC9864626 DOI: 10.3390/metabo13010066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Revised: 12/27/2022] [Accepted: 12/28/2022] [Indexed: 01/03/2023] Open
Abstract
This communication represents Part III of our series of reports based on the applications of human saliva as a useful and conveniently collectable medium for the discovery, identification and monitoring of biomarkers, which are of some merit for the diagnosis of human diseases. Such biomarkers, or others reflecting the dysfunction of specific disease-associated metabolic pathways, may also be employed for the prognostic pathological tracking of these diseases. Part I of this series set the experimental and logistical groundwork for this report, and the preceding paper, Part II, featured the applications of newly developed metabolomics technologies to the diagnosis and severity grading of human cancer conditions, both oral and systemic. Clearly, there are many benefits, both scientific and economic, associated with the donation of human saliva samples (usually as whole mouth saliva) from humans consenting to and participating in investigations focused on the discovery of biomolecular markers of diseases. These include usually non-invasive collection protocols, relatively low cost when compared against blood sample collection, and no requirement for clinical supervision during collection episodes. This paper is centred on the employment and value of 'state-of-the-art' metabolomics technologies to the diagnosis and prognosis of a wide range of non-cancerous human diseases. Firstly, these include common oral diseases such as periodontal diseases (from type 1 (gingivitis) to type 4 (advanced periodontitis)), and dental caries. Secondly, a wide range of extra-oral (systemic) conditions are covered, most notably diabetes types 1 and 2, cardiovascular and neurological diseases, and Sjögren's syndrome, along with a series of viral infections, e.g., pharyngitis, influenza, HIV and COVID-19. Since the authors' major research interests lie in the area of the principles and applications of NMR-linked metabolomics techniques, many, but not all, of the studies reviewed were conducted using these technologies, with special attention being given to recommended protocols for their operation and management, for example, satisfactory experimental model designs; sample collection and laboratory processing techniques; the selection of sample-specific NMR pulse sequences for saliva analysis; and strategies available for the confirmation of resonance assignments for both endogenous and exogenous molecules in this biofluid. This article also features an original case study, which is focussed on the use of NMR-based salivary metabolomics techniques to provide some key biomarkers for the diagnosis of pharyngitis, and an example of how to 'police' such studies and to recognise participants who perceive that they actually have this disorder but do not from their metabolic profiles and multivariate analysis pattern-based clusterings. The biochemical and clinical significance of these multidimensional metabolomics investigations are discussed in detail.
Collapse
|
41
|
Pittman TW, Decsi DB, Punyadeera C, Henry CS. Saliva-based microfluidic point-of-care diagnostic. Theranostics 2023; 13:1091-1108. [PMID: 36793864 PMCID: PMC9925318 DOI: 10.7150/thno.78872] [Citation(s) in RCA: 23] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 01/11/2023] [Indexed: 02/04/2023] Open
Abstract
There has been a long-standing interest in point-of-care (POC) diagnostics as a tool to improve patient care because it can provide rapid, actionable results near the patient. Some of the successful examples of POC testing include lateral flow assays, urine dipsticks, and glucometers. Unfortunately, POC analysis is somewhat limited by the ability to manufacture simple devices to selectively measure disease specific biomarkers and the need for invasive biological sampling. Next generation POCs are being developed that make use of microfluidic devices to detect biomarkers in biological fluids in a non-invasive manner, addressing the above-mentioned limitations. Microfluidic devices are desirable because they can provide the ability to perform additional sample processing steps not available in existing commercial diagnostics. As a result, they can provide more sensitive and selective analysis. While most POC methods make use of blood or urine as a sample matrix, there has been a growing push to use saliva as a diagnostic medium. Saliva represents an ideal non-invasive biofluid for detecting biomarkers because it is readily available in large quantities and analyte levels reflect those in blood. However, using saliva in microfluidic devices for POC diagnostics is a relatively new and an emerging field. The overarching aim of this review is to provide an update on recent literature focused on the use of saliva as a biological sample matrix in microfluidic devices. We will first cover the characteristics of saliva as a sample medium and then review microfluidic devices that are developed for the analysis of salivary biomarkers.
Collapse
Affiliation(s)
- Trey W Pittman
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA
| | - Daniel Balazs Decsi
- Centre for Biomedical Technologies, School of Biomedical Sciences, Faculty of Health, QUT.,Griffith Institute for Drug Discover, Griffith University, Nathan, Australia
| | - Chamindie Punyadeera
- Griffith Institute for Drug Discover, Griffith University, Nathan, Australia.,Menzies Health Institute, Griffith University, Gold Coast, Australia.,Translational Research Institute, Woolloongabba, Australia
| | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA.,Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Rd., Pathumwan, Bangkok 10330, Thailand
| |
Collapse
|
42
|
Oliveira MJ, Dalot A, Fortunato E, Martins R, Byrne HJ, Franco R, Águas H. Microfluidic SERS devices: brightening the future of bioanalysis. DISCOVER MATERIALS 2022; 2:12. [PMID: 36536830 PMCID: PMC9751519 DOI: 10.1007/s43939-022-00033-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 11/29/2022] [Indexed: 06/17/2023]
Abstract
A new avenue has opened up for applications of surface-enhanced Raman spectroscopy (SERS) in the biomedical field, mainly due to the striking advantages offered by SERS tags. SERS tags provide indirect identification of analytes with rich and highly specific spectral fingerprint information, high sensitivity, and outstanding multiplexing potential, making them very useful in in vitro and in vivo assays. The recent and innovative advances in nanomaterial science, novel Raman reporters, and emerging bioconjugation protocols have helped develop ultra-bright SERS tags as powerful tools for multiplex SERS-based detection and diagnosis applications. Nevertheless, to translate SERS platforms to real-world problems, some challenges, especially for clinical applications, must be addressed. This review presents the current understanding of the factors influencing the quality of SERS tags and the strategies commonly employed to improve not only spectral quality but the specificity and reproducibility of the interaction of the analyte with the target ligand. It further explores some of the most common approaches which have emerged for coupling SERS with microfluidic technologies, for biomedical applications. The importance of understanding microfluidic production and characterisation to yield excellent device quality while ensuring high throughput production are emphasised and explored, after which, the challenges and approaches developed to fulfil the potential that SERS-based microfluidics have to offer are described.
Collapse
Affiliation(s)
- Maria João Oliveira
- CENIMAT|i3N, Department of Materials Science, School of Science and Technology, NOVA University Lisbon and, CEMOP/UNINOVA, Caparica, Portugal
- Associate Laboratory i4HB—Institute for Health and Bioeconomy, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal
- UCIBIO—Applied Molecular Biosciences Unit, Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal
| | - Ana Dalot
- CENIMAT|i3N, Department of Materials Science, School of Science and Technology, NOVA University Lisbon and, CEMOP/UNINOVA, Caparica, Portugal
- Associate Laboratory i4HB—Institute for Health and Bioeconomy, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal
- UCIBIO—Applied Molecular Biosciences Unit, Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal
| | - Elvira Fortunato
- CENIMAT|i3N, Department of Materials Science, School of Science and Technology, NOVA University Lisbon and, CEMOP/UNINOVA, Caparica, Portugal
| | - Rodrigo Martins
- CENIMAT|i3N, Department of Materials Science, School of Science and Technology, NOVA University Lisbon and, CEMOP/UNINOVA, Caparica, Portugal
| | - Hugh J. Byrne
- FOCAS Research Institute, Technological University Dublin, Camden Row, Dublin 8, Dublin, Ireland
| | - Ricardo Franco
- Associate Laboratory i4HB—Institute for Health and Bioeconomy, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal
- UCIBIO—Applied Molecular Biosciences Unit, Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal
| | - Hugo Águas
- CENIMAT|i3N, Department of Materials Science, School of Science and Technology, NOVA University Lisbon and, CEMOP/UNINOVA, Caparica, Portugal
| |
Collapse
|
43
|
CRISPR-Cas-mediated diagnostics. Trends Biotechnol 2022; 40:1326-1345. [PMID: 35595574 DOI: 10.1016/j.tibtech.2022.04.006] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 04/06/2022] [Accepted: 04/12/2022] [Indexed: 01/21/2023]
Abstract
An ideal molecular diagnostic method should be sensitive, specific, low cost, rapid, portable, and easy to operate. Traditional nucleic acid detection methods based mainly on PCR technology have not only high sensitivity and specificity, but also some limitations, such as the need for expensive equipment and skilled technicians, being both time and labor intensive, and difficult to implement in some regions. However, with the continuous development of CRISPR-Cas technology and its application in molecular diagnosis, new approaches have been used for the construction of molecular diagnostic systems. In this review, we discuss recent advances in CRISPR-based molecular diagnostic technologies and highlight the revolution they bring to the field of molecular diagnostics.
Collapse
|
44
|
Current Trends and Challenges in Point-of-care Urinalysis of Biomarkers in Trace Amounts. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
45
|
Theel EK, Schwaminger SP. Microfluidic Approaches for Affinity-Based Exosome Separation. Int J Mol Sci 2022; 23:ijms23169004. [PMID: 36012270 PMCID: PMC9409173 DOI: 10.3390/ijms23169004] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 08/09/2022] [Accepted: 08/10/2022] [Indexed: 12/13/2022] Open
Abstract
As a subspecies of extracellular vesicles (EVs), exosomes have provided promising results in diagnostic and theranostic applications in recent years. The nanometer-sized exosomes can be extracted by liquid biopsy from almost all body fluids, making them especially suitable for mainly non-invasive point-of-care (POC) applications. To achieve this, exosomes must first be separated from the respective biofluid. Impurities with similar properties, heterogeneity of exosome characteristics, and time-related biofouling complicate the separation. This practical review presents the state-of-the-art methods available for the separation of exosomes. Furthermore, it is shown how new separation methods can be developed. A particular focus lies on the fabrication and design of microfluidic devices using highly selective affinity separation. Due to their compactness, quick analysis time and portable form factor, these microfluidic devices are particularly suitable to deliver fast and reliable results for POC applications. For these devices, new manufacturing methods (e.g., laminating, replica molding and 3D printing) that use low-cost materials and do not require clean rooms are presented. Additionally, special flow routes and patterns that increase contact surfaces, as well as residence time, and thus improve affinity purification are displayed. Finally, various analyses are shown that can be used to evaluate the separation results of a newly developed device. Overall, this review paper provides a toolbox for developing new microfluidic affinity devices for exosome separation.
Collapse
Affiliation(s)
- Eike K. Theel
- Bioseparation Engineering Group, School of Engineering and Design, Technical University of Munich, Boltzmannstraße 15, 85748 Garching bei München, Germany
| | - Sebastian P. Schwaminger
- Bioseparation Engineering Group, School of Engineering and Design, Technical University of Munich, Boltzmannstraße 15, 85748 Garching bei München, Germany
- Division of Medicinal Chemistry, Otto Loewi Research Center, Medical University of Graz, Neue Stiftingtalstraße 6, 8010 Graz, Austria
- Correspondence:
| |
Collapse
|
46
|
Sande MG, Ferreira D, Rodrigues JL, Melo LDR, Linke D, Silva CJ, Moreira FTC, Sales MGF, Rodrigues LR. Electrochemical Aptasensor for the Detection of the Key Virulence Factor YadA of Yersinia enterocolitica. BIOSENSORS 2022; 12:bios12080614. [PMID: 36005012 PMCID: PMC9405658 DOI: 10.3390/bios12080614] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 08/02/2022] [Accepted: 08/06/2022] [Indexed: 05/31/2023]
Abstract
New point-of-care (POC) diagnosis of bacterial infections are imperative to overcome the deficiencies of conventional methods, such as culture and molecular methods. In this study, we identified new aptamers that bind to the virulence factor Yersinia adhesin A (YadA) of Yersinia enterocolitica using cell-systematic evolution of ligands by exponential enrichment (cell-SELEX). Escherichia coli expressing YadA on the cell surface was used as a target cell. After eight cycles of selection, the final aptamer pool was sequenced by high throughput sequencing using the Illumina Novaseq platform. The sequencing data, analyzed using the Geneious software, was aligned, filtered and demultiplexed to obtain the key nucleotides possibly involved in the target binding. The most promising aptamer candidate, Apt1, bound specifically to YadA with a dissociation constant (Kd) of 11 nM. Apt1 was used to develop a simple electrochemical biosensor with a two-step, label-free design towards the detection of YadA. The sensor surface modifications and its ability to bind successfully and stably to YadA were confirmed by cyclic voltammetry, impedance spectroscopy and square wave voltammetry. The biosensor enabled the detection of YadA in a linear range between 7.0 × 104 and 7.0 × 107 CFU mL−1 and showed a square correlation coefficient >0.99. The standard deviation and the limit of detection was ~2.5% and 7.0 × 104 CFU mL−1, respectively. Overall, the results suggest that this novel biosensor incorporating Apt1 can potentially be used as a sensitive POC detection system to aid the diagnosis of Y. enterocolitica infections. Furthermore, this simple yet innovative approach could be replicated to select aptamers for other (bacterial) targets and to develop the corresponding biosensors for their detection.
Collapse
Affiliation(s)
- Maria G. Sande
- CEB—Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga, Portugal
| | - Débora Ferreira
- CEB—Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga, Portugal
| | - Joana L. Rodrigues
- CEB—Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga, Portugal
| | - Luís D. R. Melo
- CEB—Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga, Portugal
| | - Dirk Linke
- Section for Genetics and Evolutionary Biology, Department of Biosciences, University of Oslo, 0316 Oslo, Norway
| | - Carla J. Silva
- CENTI—Center for Nanotechnology and Smart Materials, Rua Fernando Mesquita 278, 4760-034 Vila Nova de Famalicão, Portugal
- CITEVE—Technological Center for the Textile and Clothing Industries of Portugal, Rua Fernando Mesquita 2785, 4760-034 Vila Nova de Famalicão, Portugal
| | - Felismina T. C. Moreira
- CEB—Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga, Portugal
- BioMark-CINTESIS/ISEP, School of Engineering, Polytechnic Institute of Porto, 4219-015 Porto, Portugal
| | - Maria Goreti F. Sales
- CEB—Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga, Portugal
- BioMark-CINTESIS/ISEP, School of Engineering, Polytechnic Institute of Porto, 4219-015 Porto, Portugal
| | - Ligia R. Rodrigues
- CEB—Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga, Portugal
| |
Collapse
|
47
|
Point-of-Care Diagnostics for Farm Animal Diseases: From Biosensors to Integrated Lab-on-Chip Devices. BIOSENSORS 2022; 12:bios12070455. [PMID: 35884258 PMCID: PMC9312888 DOI: 10.3390/bios12070455] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 06/22/2022] [Accepted: 06/23/2022] [Indexed: 02/06/2023]
Abstract
Zoonoses and animal diseases threaten human health and livestock biosecurity and productivity. Currently, laboratory confirmation of animal disease outbreaks requires centralized laboratories and trained personnel; it is expensive and time-consuming, and it often does not coincide with the onset or progress of diseases. Point-of-care (POC) diagnostics are rapid, simple, and cost-effective devices and tests, that can be directly applied on field for the detection of animal pathogens. The development of POC diagnostics for use in human medicine has displayed remarkable progress. Nevertheless, animal POC testing has not yet unfolded its full potential. POC devices and tests for animal diseases face many challenges, such as insufficient validation, simplicity, and portability. Emerging technologies and advanced materials are expected to overcome some of these challenges and could popularize animal POC testing. This review aims to: (i) present the main concepts and formats of POC devices and tests, such as lateral flow assays and lab-on-chip devices; (ii) summarize the mode of operation and recent advances in biosensor and POC devices for the detection of farm animal diseases; (iii) present some of the regulatory aspects of POC commercialization in the EU, USA, and Japan; and (iv) summarize the challenges and future perspectives of animal POC testing.
Collapse
|
48
|
Rahman M, Islam KR, Islam MR, Islam MJ, Kaysir MR, Akter M, Rahman MA, Alam SMM. A Critical Review on the Sensing, Control, and Manipulation of Single Molecules on Optofluidic Devices. MICROMACHINES 2022; 13:968. [PMID: 35744582 PMCID: PMC9229244 DOI: 10.3390/mi13060968] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Revised: 05/19/2022] [Accepted: 05/23/2022] [Indexed: 02/06/2023]
Abstract
Single-molecule techniques have shifted the paradigm of biological measurements from ensemble measurements to probing individual molecules and propelled a rapid revolution in related fields. Compared to ensemble measurements of biomolecules, single-molecule techniques provide a breadth of information with a high spatial and temporal resolution at the molecular level. Usually, optical and electrical methods are two commonly employed methods for probing single molecules, and some platforms even offer the integration of these two methods such as optofluidics. The recent spark in technological advancement and the tremendous leap in fabrication techniques, microfluidics, and integrated optofluidics are paving the way toward low cost, chip-scale, portable, and point-of-care diagnostic and single-molecule analysis tools. This review provides the fundamentals and overview of commonly employed single-molecule methods including optical methods, electrical methods, force-based methods, combinatorial integrated methods, etc. In most single-molecule experiments, the ability to manipulate and exercise precise control over individual molecules plays a vital role, which sometimes defines the capabilities and limits of the operation. This review discusses different manipulation techniques including sorting and trapping individual particles. An insight into the control of single molecules is provided that mainly discusses the recent development of electrical control over single molecules. Overall, this review is designed to provide the fundamentals and recent advancements in different single-molecule techniques and their applications, with a special focus on the detection, manipulation, and control of single molecules on chip-scale devices.
Collapse
Affiliation(s)
- Mahmudur Rahman
- Department of Electrical and Electronic Engineering, Dhaka University of Engineering & Technology, Gazipur 1707, Bangladesh; (M.R.); (K.R.I.); (M.R.I.); (M.A.); (M.A.R.)
| | - Kazi Rafiqul Islam
- Department of Electrical and Electronic Engineering, Dhaka University of Engineering & Technology, Gazipur 1707, Bangladesh; (M.R.); (K.R.I.); (M.R.I.); (M.A.); (M.A.R.)
| | - Md. Rashedul Islam
- Department of Electrical and Electronic Engineering, Dhaka University of Engineering & Technology, Gazipur 1707, Bangladesh; (M.R.); (K.R.I.); (M.R.I.); (M.A.); (M.A.R.)
| | - Md. Jahirul Islam
- Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh;
| | - Md. Rejvi Kaysir
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada;
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada
| | - Masuma Akter
- Department of Electrical and Electronic Engineering, Dhaka University of Engineering & Technology, Gazipur 1707, Bangladesh; (M.R.); (K.R.I.); (M.R.I.); (M.A.); (M.A.R.)
| | - Md. Arifur Rahman
- Department of Electrical and Electronic Engineering, Dhaka University of Engineering & Technology, Gazipur 1707, Bangladesh; (M.R.); (K.R.I.); (M.R.I.); (M.A.); (M.A.R.)
| | - S. M. Mahfuz Alam
- Department of Electrical and Electronic Engineering, Dhaka University of Engineering & Technology, Gazipur 1707, Bangladesh; (M.R.); (K.R.I.); (M.R.I.); (M.A.); (M.A.R.)
| |
Collapse
|
49
|
Ghafouri T, Manavizadeh N. Design and simulation of a millifluidic device for differential detection of SARS-CoV-2 and H1N1 based on triboelectricity. Bioelectrochemistry 2022; 145:108096. [PMID: 35316730 PMCID: PMC8923711 DOI: 10.1016/j.bioelechem.2022.108096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 03/09/2022] [Accepted: 03/13/2022] [Indexed: 12/02/2022]
Abstract
Differential diagnosis of pathogenic diseases, presently coronavirus disease 2019 (COVID-19) and influenza, is crucial with due attention to their superspreading events, presumably long incubation period, particular complications, and treatments. In this paper, a label-free, self-powered, and ultrafast immunosensor device working based on triboelectric effect is proposed. Equilibrium constants of specific antibody-antigen reactions are accompanied by IEP-relevant electric charges of antigens to recognize SARS-CoV-2 and H1N1. Simulation attributes including fluid flow and geometrical parameters are optimized so that the maximum capture efficiency of 85.63% is achieved. Accordingly, antibody-antigen complexes form electric double layers (EDLs) across the channel interfaces. The resultant built-in electric field affects the following external electric field derived from triboelectricity, leading to the variation of open-circuit voltage as a sensing metric. The device is flexible to operate in conductor-to-dielectric single-electrode and contact-separation modes simultaneously. While the detection limit is reduced utilizing the single-electrode mode compared to the latter one, surface treatment of the triboelectric pair contributes to the sensitivity enhancement. A threshold value equal to −4.113 V is featured to discriminate these two viruses in a vast detectable region; however, further surface engineering can allow the on-site detection of any electrically-charged pathogen applying the emerging triboelectric immunosensor enjoying a lower detection limit.
Collapse
|
50
|
Stauss M, Keevil B, Woywodt A. Point-of-Care Testing: Home Is Where the Lab Is. KIDNEY360 2022; 3:1285-1288. [PMID: 35919524 PMCID: PMC9337901 DOI: 10.34067/kid.0000942022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Accepted: 05/06/2022] [Indexed: 01/11/2023]
Affiliation(s)
- Madelena Stauss
- Department of Nephrology, Lancashire Teaching Hospitals NHS Foundation Trust, Preston, United Kingdom
| | - Brian Keevil
- Department of Biochemistry, Manchester University Foundation Trust, Wythenshawe, Manchester, United Kingdom
| | - Alexander Woywodt
- Department of Nephrology, Lancashire Teaching Hospitals NHS Foundation Trust, Preston, United Kingdom
| |
Collapse
|