1
|
De Marco A, Sicard P, Feng Z, Agathokleous E, Alonso R, Araminiene V, Augustatis A, Badea O, Beasley JC, Branquinho C, Bruckman VJ, Collalti A, David‐Schwartz R, Domingos M, Du E, Garcia Gomez H, Hashimoto S, Hoshika Y, Jakovljevic T, McNulty S, Oksanen E, Omidi Khaniabadi Y, Prescher A, Saitanis CJ, Sase H, Schmitz A, Voigt G, Watanabe M, Wood MD, Kozlov MV, Paoletti E. Strategic roadmap to assess forest vulnerability under air pollution and climate change. Glob Chang Biol 2022; 28:5062-5085. [PMID: 35642454 PMCID: PMC9541114 DOI: 10.1111/gcb.16278] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 03/02/2022] [Accepted: 05/18/2022] [Indexed: 05/13/2023]
Abstract
Although it is an integral part of global change, most of the research addressing the effects of climate change on forests have overlooked the role of environmental pollution. Similarly, most studies investigating the effects of air pollutants on forests have generally neglected the impacts of climate change. We review the current knowledge on combined air pollution and climate change effects on global forest ecosystems and identify several key research priorities as a roadmap for the future. Specifically, we recommend (1) the establishment of much denser array of monitoring sites, particularly in the South Hemisphere; (2) further integration of ground and satellite monitoring; (3) generation of flux-based standards and critical levels taking into account the sensitivity of dominant forest tree species; (4) long-term monitoring of N, S, P cycles and base cations deposition together at global scale; (5) intensification of experimental studies, addressing the combined effects of different abiotic factors on forests by assuring a better representation of taxonomic and functional diversity across the ~73,000 tree species on Earth; (6) more experimental focus on phenomics and genomics; (7) improved knowledge on key processes regulating the dynamics of radionuclides in forest systems; and (8) development of models integrating air pollution and climate change data from long-term monitoring programs.
Collapse
Affiliation(s)
| | | | - Zhaozhong Feng
- Key Laboratory of Agro‐Meteorology of Jiangsu Province, School of Applied MeteorologyNanjing University of Information Science & TechnologyNanjingChina
| | - Evgenios Agathokleous
- Key Laboratory of Agro‐Meteorology of Jiangsu Province, School of Applied MeteorologyNanjing University of Information Science & TechnologyNanjingChina
| | - Rocio Alonso
- Ecotoxicology of Air Pollution, CIEMATMadridSpain
| | - Valda Araminiene
- Lithuanian Research Centre for Agriculture and ForestryKaunasLithuania
| | - Algirdas Augustatis
- Faculty of Forest Sciences and EcologyVytautas Magnus UniversityKaunasLithuania
| | - Ovidiu Badea
- “Marin Drăcea” National Institute for Research and Development in ForestryVoluntariRomania
- Faculty of Silviculture and Forest Engineering“Transilvania” UniversityBraşovRomania
| | - James C. Beasley
- Savannah River Ecology Laboratory and Warnell School of Forestry and Natural ResourcesUniversity of GeorgiaAikenSouth CarolinaUSA
| | - Cristina Branquinho
- Centre for Ecology, Evolution and Environmental Changes, Faculdade de CiênciasUniversidade de LisboaLisbonPortugal
| | - Viktor J. Bruckman
- Commission for Interdisciplinary Ecological StudiesAustrian Academy of SciencesViennaAustria
| | | | | | - Marisa Domingos
- Instituto de BotanicaNucleo de Pesquisa em EcologiaSao PauloBrazil
| | - Enzai Du
- Faculty of Geographical ScienceBeijing Normal UniversityBeijingChina
| | | | - Shoji Hashimoto
- Department of Forest SoilsForestry and Forest Products Research InstituteTsukubaJapan
| | | | | | | | - Elina Oksanen
- Department of Environmental and Biological SciencesUniversity of Eastern FinlandJoensuuFinland
| | - Yusef Omidi Khaniabadi
- Department of Environmental Health EngineeringIndustrial Medial and Health, Petroleum Industry Health Organization (PIHO)AhvazIran
| | | | - Costas J. Saitanis
- Lab of Ecology and Environmental ScienceAgricultural University of AthensAthensGreece
| | - Hiroyuki Sase
- Ecological Impact Research DepartmentAsia Center for Air Pollution Research (ACAP)NiigataJapan
| | - Andreas Schmitz
- State Agency for Nature, Environment and Consumer Protection of North Rhine‐WestphaliaRecklinghausenGermany
| | | | - Makoto Watanabe
- Institute of AgricultureTokyo University of Agriculture and Technology (TUAT)FuchuJapan
| | - Michael D. Wood
- School of Science, Engineering and EnvironmentUniversity of SalfordSalfordUK
| | | | - Elena Paoletti
- Department of Forest SoilsForestry and Forest Products Research InstituteTsukubaJapan
| |
Collapse
|
2
|
Hachenberg J, Sauerwald A, Brunke H, Ludwig S, Scaal M, Prescher A, Eichler C. Suturing methods in prolapse surgery: a biomechanical analysis. Int Urogynecol J 2021; 32:1539-1544. [PMID: 33263782 PMCID: PMC8203505 DOI: 10.1007/s00192-020-04609-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 11/10/2020] [Indexed: 11/07/2022]
Abstract
INTRODUCTION Pelvic organ prolapse is a common problem in urogynecological surgery. Abdominal and laparoscopic sacrocolpopexy is currently considered to be the gold standard of treatment. The main problem remains the anatomical point of fixation as well as how sutures are placed. We evaluated the biomechanical difference between an in-line ligament suture versus an orthogonal ligament suture and a single suture versus a continuous suture at the anterior longitudinal ligament in an in-vitro, sacrocolpopexy model. METHODS Biomechanical in-vitro testing was performed on human, non-embalmed, female cadaver pelvises. An Instron test frame (tensinometer) was used for load/ displacement analysis. The average patient age was 75 years. Ligament preparation yielded 15 ligaments available for testing. Recorded parameters were the ultimate load, failure displacement, and stiffness. RESULTS This in-vitro analysis of different suturing methods showed the difference between an orthogonal and an in-line approach to be the ultimate load. Orthogonal sutures displayed an ultimate load of 80 N while in-line suturing yielded only 57 N (p < 0.05). For the anterior longitudinal ligament, this study demonstrated that continuous suture is significantly superior to a single suture regarding failure displacement (p < 0.05). CONCLUSION We established baseline biomechanical parameters for the sacrospinous ligament and anterior longitudinal ligament. An orthogonal suture is superior to an in-line suture in an in-vitro model. A continuous suture is superior to a single suture at the anterior longitudinal ligament. Clinical trials might be able to evaluate whether any clinical significance can be established from these findings.
Collapse
Affiliation(s)
- J Hachenberg
- Department of Gynecology and Obstetrics, Hannover Medical School, Hannover, Germany.
| | - A Sauerwald
- Department of Gynecology and Obstetrics, St. Marien Hospital Düren, Düren, Germany
| | - H Brunke
- Department of Gynecology and Obstetrics, Frauenklinik Holweide, Kliniken der Stadt Köln, Cologne, Germany
| | - S Ludwig
- Department of Gynecology and Obstetrics, University of Cologne, Cologne, Germany
| | - M Scaal
- Department of Anatomy II, University of Cologne, Cologne, Germany
| | - A Prescher
- Department of Anatomy, RWTH Aachen University, Aachen, Germany
| | - C Eichler
- Department of Gynecology and Obstetrics, St. Marien Hospital Düren, Düren, Germany
- Department of Gynecology and Obstetrics, University of Cologne, Cologne, Germany
- DZMGS (German Center for Material Science in Gynecology and Senology), Cologne, Germany
| |
Collapse
|
3
|
Möhlhenrich SC, Ernst K, Peters F, Kniha K, Chhatwani S, Prescher A, Danesh G, Hölzle F, Modabber A. Immediate dental and skeletal influence of distractor position on surgically assisted rapid palatal expansion with or without pterygomaxillary disjunction. Int J Oral Maxillofac Surg 2020; 50:649-656. [PMID: 33131988 DOI: 10.1016/j.ijom.2020.10.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 08/18/2020] [Accepted: 10/08/2020] [Indexed: 10/23/2022]
Abstract
The outcome of surgically assisted rapid palatal expansion (SARPE) can be affected by pterygomaxillary disjunction (PMD) and the distractor position. In this study, SARPE was performed, with or without PMD, in 20 fresh cadaver heads. Transverse expansion was conducted twice using a bone-borne distractor in the anterior and posterior positions, resulting in four groups (n=10). Cone beam computed tomography scans were completed before and after SARPE to evaluate maxillary changes. A comparative anterior decrease and posterior increase in midpalatal opening resulted from SARPE with PMD combined with a posteriorly placed distractor. Significant differences in the internal transverse changes were found between the two SARPE techniques combined with an anterior distractor at the level of the premolars and molars for alveolar ridge width (P=0.040, P=0.024), and at the level of the molars for the dental crown width (P=0.017) and corresponding tooth cusp width (P=0.018). In contrast, using a posteriorly placed distractor led to a significant difference for tooth cusp width only (P=0.050). No statistically significant differences were found between external transverse changes or between distractor positions. PMD is more important in achieving a more uniform and parallel transverse expansion pattern than the distractor position. However, a posterior distractor seems to intensify the effects of PMD.
Collapse
Affiliation(s)
- S C Möhlhenrich
- Department of Orthodontics, University of Witten/Herdecke, Witten, Germany; Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Aachen, Germany.
| | - K Ernst
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Aachen, Germany
| | - F Peters
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Aachen, Germany
| | - K Kniha
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Aachen, Germany
| | - S Chhatwani
- Department of Orthodontics, University of Witten/Herdecke, Witten, Germany
| | - A Prescher
- Institute of Molecular and Cellular Anatomy, Medical Faculty of RWTH-Aachen, Aachen, Germany
| | - G Danesh
- Department of Orthodontics, University of Witten/Herdecke, Witten, Germany
| | - F Hölzle
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Aachen, Germany
| | - A Modabber
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Aachen, Germany
| |
Collapse
|
4
|
Bock A, Modabber A, Hölzle F, Prescher A, Classen-Linke I. Improvement of anatomical knowledge and surgical skills in head and neck region — An interdisciplinary hands-on course for clinical students. Ann Anat 2019; 224:97-101. [DOI: 10.1016/j.aanat.2019.03.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Revised: 02/22/2019] [Accepted: 03/25/2019] [Indexed: 11/26/2022]
|
5
|
Karius T, Deborre C, Wirtz DC, Burger C, Prescher A, Fölsch A, Kabir K, Pflugmacher R, Goost H. Radiofrequency-activated PMMA-augmentation through cannulated pedicle screws: A cadaver study to determine the biomechanical benefits in the osteoporotic spine. Technol Health Care 2017; 25:327-342. [PMID: 27886018 DOI: 10.3233/thc-161273] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
INTRODUCTION PMMA-augmentation of pedicle screws strengthens the bone-screw-interface reducing cut-out risk. Injection of fluid cement bears a higher risk of extravasation, with difficulty of application because of inconsistent viscosity and limited injection time. OBJECTIVE To test a new method of cement augmentation of pedicle screws using radiofrequency-activated PMMA, which is suspected to be easier to apply and have less extravasations. METHODS Twenty-seven fresh-frozen human cadaver lumbar spines were divided into 18 osteoporotic (BMD ≤ 0.8 g/cm2) and 9 non-osteoporotic (BMD > 0.8 g/cm2) vertebral bodies. Bipedicular cannulated pedicle screws were implanted into the vertebral bodies; right screws were augmented with ultra-high viscosity PMMA, whereas un-cemented left pedicle screws served as negative controls. Cement distribution was controlled with fluoroscopy and CT scans. Axial pullout forces of the screws were measured with a material testing machine, and results were analyzed statistically. RESULTS Fluoroscopy and CT scans showed that in all cases an adequately big cement depot with homogenous form and no signs of extravasation was injected. Pullout forces showed significant differences (p < 0.001) between the augmented and non-augmented pedicle screws for bone densities below 0.8 g/cm2 (661.9 N ± 439) and over 0.8 g/cm2 (744.9 N ± 415). CONCLUSIONS Pullout-forces were significantly increased in osteoporotic as well as in non-osteoporotic vertebral bodies without a significant difference between these groups using this standardized, simple procedure with increased control and less complications like extravasation.
Collapse
Affiliation(s)
- T Karius
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany.,Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - C Deborre
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany.,Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - D C Wirtz
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - C Burger
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - A Prescher
- Institute of Anatomy, University Hospital RWTH Aachen, Aachen, Germany
| | - A Fölsch
- Department of Orthopaedics, University Hospital Marburg, Marburg, Germany
| | - K Kabir
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - R Pflugmacher
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - H Goost
- Department of Orthopaedics and Trauma Surgery, Hospital Wermelskirchen, Wermelskirchen, Germany
| |
Collapse
|
6
|
Hackl M, Andermahr J, Staat M, Bremer I, Borggrefe J, Prescher A, Müller LP, Wegmann K. Suture button reconstruction of the central band of the interosseous membrane in Essex-Lopresti lesions: a comparative biomechanical investigation. J Hand Surg Eur Vol 2017; 42:370-376. [PMID: 27573130 DOI: 10.1177/1753193416665943] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
UNLABELLED Surgical reconstruction of the interosseous membrane may restore longitudinal forearm stability in Essex-Lopresti lesions. This study aimed to compare the longitudinal stability of the intact forearm with a single-bundle and a double-bundle reconstruction of the central band of the interosseous membrane using digital image correlation with a three-dimensional camera system. Single and cyclic axial loading of eight fresh-frozen forearm specimens was carried out in the intact state, after creation of an Essex-Lopresti lesion, after a single-bundle and after a double-bundle reconstruction of the central band using a TightRope® (Arthrex GmbH, Munich, Germany) construct. Instability significantly increased after creation of an Essex-Lopresti lesion. The stability of intact specimens was similar to both reconstruction techniques. The results of this study suggest that TightRope® reconstruction of the central band restores longitudinal forearm stability. However, the single-bundle technique may be less reliable than double-bundle reconstruction. LEVEL OF EVIDENCE Basic Science Study.
Collapse
Affiliation(s)
- M Hackl
- 1 Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Cologne, Germany.,2 Cologne Center for Musculoskeletal Biomechanics (CCMB), University of Cologne, Cologne, Germany
| | - J Andermahr
- 3 Department of Orthopedic and Trauma Surgery, Hospital of the University of Bonn, Bonn, Germany
| | - M Staat
- 4 Institute of Bioengineering, Aachen University of Applied Sciences, Jülich, Germany
| | - I Bremer
- 3 Department of Orthopedic and Trauma Surgery, Hospital of the University of Bonn, Bonn, Germany
| | - J Borggrefe
- 5 Department of Radiology, University Medical Center of Cologne, Cologne, Germany
| | - A Prescher
- 6 Institute of Molecular and Cellular Anatomy, Medical Faculty of RWTH-Aachen, Aachen, Germany
| | - L P Müller
- 1 Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Cologne, Germany.,2 Cologne Center for Musculoskeletal Biomechanics (CCMB), University of Cologne, Cologne, Germany
| | - K Wegmann
- 1 Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Cologne, Germany.,2 Cologne Center for Musculoskeletal Biomechanics (CCMB), University of Cologne, Cologne, Germany
| |
Collapse
|
7
|
Michalik R, Schrading S, Dirrichs T, Prescher A, Kuhl CK, Tingart M, Rath B. New approach for predictive measurement of knee cartilage defects with three-dimensional printing based on CT-arthrography: A feasibility study. J Orthop 2016; 14:95-103. [PMID: 27829733 DOI: 10.1016/j.jor.2016.10.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2016] [Accepted: 10/13/2016] [Indexed: 11/26/2022] Open
Abstract
PURPOSE The aim was to prove the possibility of creating an exact module of knee cartilage defects using 3D printing. METHODS Defects were created in cadaver knees. CT-arthrography and 3-Tesla MRI were performed. Based on CTA images a model of the cartilage was created using 3D printing. Defect-sizes in the imaging modalities were compared. RESULTS Estimated lesion area in 3D model differed approximately 5% comparing to the defect sizes in knees. MRI underestimated the defect on average of 12%, whereas the CTA overestimated the defect about 3%. CONCLUSIONS We proved the feasibility of creating an accurate module of knee cartilage.
Collapse
Affiliation(s)
- R Michalik
- Department of Orthopaedic Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - S Schrading
- Department of Diagnostic and Interventional Radiology, University Hospital RWTH Aachen, Aachen, Germany
| | - T Dirrichs
- Department of Diagnostic and Interventional Radiology, University Hospital RWTH Aachen, Aachen, Germany
| | - A Prescher
- Institute of Molecular and Cellular Anatomy, University RWTH Aachen, Aachen, Germany
| | - C K Kuhl
- Department of Diagnostic and Interventional Radiology, University Hospital RWTH Aachen, Aachen, Germany
| | - M Tingart
- Department of Orthopaedic Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - B Rath
- Department of Orthopaedic Surgery, University Hospital RWTH Aachen, Aachen, Germany
| |
Collapse
|
8
|
Sauerwald A, Niggl M, Puppe J, Prescher A, Scaal M, Noé GK, Schiermeier S, Warm M, Eichler C. Laparoscopic Pectopexy: A Biomechanical Analysis. PLoS One 2016; 11:e0144143. [PMID: 26844890 PMCID: PMC4741420 DOI: 10.1371/journal.pone.0144143] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2015] [Accepted: 10/13/2015] [Indexed: 11/18/2022] Open
Abstract
Introduction Pectopexy, a laparoscopic method for prolapse surgery, showed promising results in recent literature. Further improving this approach by reducing surgical time may decrease complication rates and patient morbidity. Since laparoscopic suturing is a time consuming task, we propose a single suture /mesh ileo-pectineal ligament fixation as opposed to the commonly used continues approach. Methods Evaluation was performed on human non-embalmed, fresh cadaver pelves. A total of 33 trials was performed. Eight female pelves with an average age of 75, were used. This resulted in 16 available ligaments. Recorded parameters were ultimate load, displacement at failure and stiffness. Results The ultimate load for the mesh + simplified single “interrupted” suture (MIS) group was 35 (± 12) N and 48 (± 7) N for the mesh + continuous suture (MCS) group. There was no significant difference in the ultimate load between both groups (p> 0.05). This was also true for displacement at failure measured at 37 (± 12) mm and 36 (±5) mm respectively. There was also no significant difference in stiffness and failure modes. Conclusion Given the data above we must conclude that a continuous suture is not necessary in laparoscopic mesh / ileo-pectineal ligament fixation during pectopexy. Ultimate load and displacement at failure results clearly indicate that a single suture is not inferior to a continuous approach. The use of two single sutures may improve ligamental fixation. However, overall stability should not benefit since the surgical mesh remains the limiting factor.
Collapse
Affiliation(s)
- A. Sauerwald
- Department of Gynecology and Obstetrics, Hospital Düren GmbH, Düren, Germany
| | - M. Niggl
- Breast Cancer Center, Municipal Hospital Holweide, Cologne, Germany
- Department of Gynecology and Obstetrics, Municipal Hospital Holweide, Cologne, Germany
| | - J. Puppe
- Department of Gynecology and Obstetrics, University of Cologne, Cologne, Germany
| | - A. Prescher
- Department of Anatomy, RWTH Aachen University, Aachen, Germany
| | - M. Scaal
- Department of Anatomy II, University of Cologne, Cologne, Germany
| | - G. K. Noé
- Dep. Ob/Gyn Hospitals Rhein-Kreis-Neuss, Faculty University of Witten/Herdecke, Witten, Germany
| | | | - M. Warm
- Breast Cancer Center, Municipal Hospital Holweide, Cologne, Germany
- Department of Gynecology and Obstetrics, University of Cologne, Cologne, Germany
| | - C. Eichler
- Breast Cancer Center, Municipal Hospital Holweide, Cologne, Germany
- Department of Gynecology and Obstetrics, Municipal Hospital Holweide, Cologne, Germany
- * E-mail: ;
| |
Collapse
|
9
|
Abstract
BACKGROUND High-resolution ultrasonography of the lips offers the opportunity to investigate the orbicularis oris muscle (OOM) and evaluate its morphology and function. OBJECTIVES The goals of this paper are verification of the lip structures visible on ultrasound images by using histological section preparations and recommendation of uniform standards for sonographic examinations of the lips. MATERIALS AND METHODS The lips of 78 healthy volunteers (age 4-77 years) where scanned with a Hitachi Hi Vision Avius ultrasound device equipped with a linear transducer (L75, variable frequency range 5.0-18.0 MHz). Systematic B-mode examination was performed at five defined points, and the lips where also scanned dynamically in multiple directions. The ultrasonography findings were verified by using histologic samples from five male body donors (age 72-83 years). RESULTS All parts of the OOM could be well distinguished from one another both histologically and ultrasonographically. Sonographically visible lip structures could be verified histologically. Labial glands and blood vessels of the mucosa could be identified with both methods. CONCLUSION Ultrasonography allows identification of lip structures and all parts of the OOM. Scars, injuries and atrophy of the lip musculature are well detectable. Functional examinations can visualize muscular dysfunctions and may support the diagnosis of dystonic or hypotonic functional deficits. The following parameters are mandatory for a standardized examination of the lips: sagittal and transverse images of upper and lower lips; use of anatomical "landmarks"; functional diagnostics in tensed and relaxed conditions.
Collapse
Affiliation(s)
- F L Lefarth
- Selbständiger Funktionsbereich für Phoniatrie und Pädaudiologie, Univ.-Klinikum Düsseldorf, Moorenstr. 5/Geb. 13.77, 40225, Düsseldorf, Deutschland,
| | | | | |
Collapse
|
10
|
Goost H, Deborre C, Wirtz D, Burger C, Prescher A, Fölsch C, Pflugmacher R, Kabir K. PMMA-augmentation of incompletely cannulated pedicle screws: A cadaver study to determine the benefits in the osteoporotic spine. Technol Health Care 2014; 22:607-15. [DOI: 10.3233/thc-140815] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- H. Goost
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - C. Deborre
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - D.C. Wirtz
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - C. Burger
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - A. Prescher
- Institute of Anatomy, University Hospital RWTH-Aachen, Aachen, Germany
| | - C. Fölsch
- Department of Orthopaedics, University Hospital Marburg, Marburg, Germany
| | - R. Pflugmacher
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - K. Kabir
- Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| |
Collapse
|
11
|
Abstract
Papillary tumors of the middle and inner ear have been interpreted histogenetically in many ways. In 1989 Heffner proposed the endolymphatic sac epithelium as a possible origin. These rare tumors are clinically aggressive and can cause extensive temporal bone destruction. Because of this behavior, endolymphatic sac tumors (ELST) were classified as low-grade adenocarcinomas, although metastasis has not yet been documented. Two papillary neoplasms of the temporal bone are presented, which we believe are examples of adenomatous tumors arising from the epithelium of the endolymphatic sac. One was associated with a pituitary adenoma. A third case of a papillary middle ear neoplasm is described that shows histologic features similar to the other two, but it was located in the tympanum and had no connection to the endolymphatic sac. This report focuses on clinical, radiologic, and histologic findings of papillary tumors of the temporal bone with additional emphasis on modern concepts of histogenesis and aspects of differential diagnosis.
Collapse
|
12
|
Prescher A, Brors D, von Ammon K. New anatomical description of the cavernous sinus surface and its significance in microsurgery. Skull Base Surg 2011; 7:183-91. [PMID: 17171029 PMCID: PMC1656644 DOI: 10.1055/s-2008-1058594] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
The anatomical and surgical approach to the sella region is of special interest for microsurgeons involved in ear, nose, and throat surgery, neurosurgery, ophthalmology, maxillofacial surgery, and skull base surgery. We investigated the surface morphology of the cavernous sinus and the sella turcica in 48 adult and 2 neonate specimens. To simplify the morphometric recording, distances between anatomical landmarks were defined. In addition, three triangles-the preinfundibular, the parasellar, and the internal carotid artery triangle-are introduced. These triangles are defined in order to determine the location where cranial nerves III, IV, V, and VI penetrate the dura with respect to the anterior and posterior clinoid processes and the tuberculum and dorsum sellae. The triangles were found to be symmetrical, with identical bilateral measurements, and the entry points of the cranial nerves were found to be constant. In 17 cases (34%), we found a dehiscence of the sellar diaphragm, and in 15 cases (30%), rope-like adhesions at the pituitary stalk.
Collapse
|
13
|
Abstract
Four typical manifestations of the occipital vertebra are described from both an anatomic and a radiologic point of view; the basilar process, the condylus tertius, the paracondylar process, and the isolated prebasioccipital arch. The clinical importance of the described variants is discussed.
Collapse
|
14
|
Abstract
OBJECTIVE The cause of haemorrhoidal disease is unknown, epidemiological data and histopathological findings support the hypothesis that reduced connective tissue stability is associated with the incidence of haemorrhoids. Therefore the aim of this study was to analyse the quantity and quality of collagen formation in the corpus cavernosum recti in patients with III°/IV° haemorrhoids in comparison with persons without haemorrhoids. METHOD Haemorrhoidectomy specimens of 31 patients with III°/IV° haemorrhoids were examined. The specimens of 20 persons who died a natural death and who had no haemorrhoidal disease served as the controls. The amount of collagen was estimated photometrically by calculating the collagen/protein ratio. The collagen I/III ratio served as parameter for the quality of collagen formation and was calculated using cross polarization spectroscopy. RESULTS Patients with haemorrhoids had a significantly reduced collagen/protein ratio (42.2 ± 16.2μg/mg vs 72.5±31.0μg/mg; P= 0.02) and a significantly reduced collagen I/III ratio (2.0±0.1 vs 4.6±0.3; P<0.001) compared with persons without haemorrhoidal disease. There was no correlation with patients' age or gender. CONCLUSIONS There is a fundamental disorder of collagen metabolism in patients with haemorrhoidal disease. It remains unclear whether this is due to exogenous or endogenous influences.
Collapse
Affiliation(s)
- S Willis
- Department of Surgery, Klinikum Ludwigshafen, Germany.
| | | | | | | | | |
Collapse
|
15
|
Abstract
Detailed knowledge of the complicated anatomy and topography of the paranasal sinuses is an essential requirement for successful surgery in this region. The topographical relationship to essential neighbouring structures (vessels, nerves and spaces) must be borne in mind. Typical landmarks play a particularly important role, especially for reliable orientation in endoscopic procedures. Therefore, it must be stressed that detailed anatomical knowledge of the complicated nasal and paranasal architecture is very important for the success of nasal and paranasal surgery, as well as for the avoidance of serious complications. However, this knowledge can only be acquired by performing numerous dissections of the nasal and paranasal system once a good theoretical grasp of the various structures, regions and their nomenclature has been gained. Common anatomical variations, which may lead to complicated and hazardous changes in normal anatomy, are also of particular importance and the surgeon must be familiar with these variations.
Collapse
Affiliation(s)
- A Prescher
- Institut für Molekulare und Zelluläre Anatomie der RWTH Aachen, Prosektur, Wendlingweg 2, 52074, Aachen.
| |
Collapse
|
16
|
Weisskopf M, Maus U, Ohnsorge JAK, Prescher A, Pandorf T, Birnbaum K. [Influence of disc prosthesis position on segmental motion in the lumbar spine]. Z Orthop Unfall 2010; 148:453-8. [PMID: 20135599 DOI: 10.1055/s-0029-1186189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
AIM OF THE STUDY Total disc arthroplasty is reported to maintain segmental motion. From finite element studies a rather posterior and central implantation of the prosthesis is recommended. However, there is yet no in vitro study with cadaveric specimens investigating the topic of implant positioning. METHODS Ten human lumbar spines were subjected to biomechanical testing. Flexion/extension and side-bending moments were applied from 2.5-7.5 Nm on a spine load simulator. First, the intact specimens were tested in 3 load cycles while motion was monitored with regard to the facet joints under different loads by an ultrasound-based system. An unconstrained total disc prosthesis was then implanted in a central position and the different load cycles were repeated. Finally the implant was positioned in a decentral position with an average offset of 6.2 mm for repetitive data acquisition. RESULTS Comparison of the facet joint motion in central and eccentric prosthesis positions resulted in the following averaged differences. During flexion of the lumbar spine an average difference of the reference point excursions of 0.38 mm was recorded on the ipsilateral facet joint with reference to the decentral position. For extension, the difference was 0.33 mm on average, for right side bending a difference of 0.63 mm was recorded while left side bending resulted in an average difference of 0.24 mm. The deviation of the reference markers on the contralateral facet joint showed the following average differences: for flexion 0.23 mm and for extension 0.54 mm, respectively. For side bending right/left the differences amounted to 0.18 mm and 0.39 mm. With regard to segmental motion there was no statistically significant difference for both the ipsilateral (p = 0.0564) and the contralateral (p = 0.2593) reference marker. CONCLUSIONS The comparison of the segmental motion after central and decentral implantation of a lumbar total disc prosthesis reveals differences that have, nevertheless, no statistical significance. However, for clinical use it is recommended to strive for a central position of the implant.
Collapse
Affiliation(s)
- M Weisskopf
- Abteilung Orthopädie, Sektion Wirbelsäule, Orthopädische Fachklinik Schwarzach.
| | | | | | | | | | | |
Collapse
|
17
|
Grottke O, Ntouba A, Ullrich S, Liao W, Fried E, Prescher A, Deserno T, Kuhlen T, Rossaint R. Virtual reality-based simulator for training in regional anaesthesia. Br J Anaesth 2009; 103:594-600. [DOI: 10.1093/bja/aep224] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
18
|
Birnbaum K, Phoa T, Maus U, Prescher A, Weißkopf M. Biomechanische Analyse der Lendenwirbelsäule nach Implantation einer Bandscheibenendoprothese sowie ergänzender Spondylodese als Komplikationsmanagement. Z Orthop Unfall 2009; 147:493-500. [DOI: 10.1055/s-0029-1185738] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
19
|
Gerressen M, Ghassemi A, Prescher A, van der Ven D, Riediger D. Knochentransplantate aus der proximalen Tibia im Vergleich zum klassischen Beckenkammtransplantat bei 15 Frischleichen. Zentralbl Chir 2009. [DOI: 10.1055/s-0029-1238126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
20
|
Sönmez TT, Ghassemi A, Prescher A, Hilgers RD, Riediger D. Eine vergleichende osteometrisch-morphometrische Studie zu wichtigen Spenderregionen Beckenkamm, Fibula, Skapula und Rippen. Zentralbl Chir 2009. [DOI: 10.1055/s-0029-1238163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
21
|
Birnbaum K, Pandorf T, Prescher A, Niethard F, Weißkopf M. Die hüftkopfzentrierenden Kräfte des Tractus iliotibialis bei variierendem Schenkelhalswinkel. Z Orthop Unfall 2009; 147:341-9. [DOI: 10.1055/s-2008-1039298] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
22
|
Lehnert B, Prescher A, Neuschaefer-Rube C. Is laryngeal mask airway-related vocal chord palsy always laryngeal mask airway-related? Br J Anaesth 2008; 101:882. [DOI: 10.1093/bja/aen304] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
23
|
Abstract
HISTORY AND ADMISSION FINDINGS A 66-year-old man was found to have a medullary plasmocytoma the year before admission, after sustaining a pathological fracture of the femur. During treatment for sciatica his general condition deteriorated and he developed abdominal pain. Laboratory tests suggested a septic process. INVESTIGATIONS The clinical and sonographic findings and computed tomography suggested an acute cholecystitis. TREATMENT AND COURSE A cholecystectomy was performed. Microscopic examination revealed metastatic infiltration of the gall bladder by a medullary plasmocytoma. CONCLUSION Secondary tumours of the gallbladder considered are thought to be rare. Since 1863 only 95 cases have been reported. The case discussed here is only the second one in which the metastatic tumor was a medullary plasmocytoma. But a search for published and confirmed cases indicates that secondary tumors of the gall bladder are not so rare. Metastatic tumors of the gall bladder should be kept in mind in the differential diagnosis of acute cholecystitis, especially in patients with an advanced primary tumor.
Collapse
Affiliation(s)
- D Schuster
- Institut für Neuroanatomie, RWTH Aachen.
| | | | | | | |
Collapse
|
24
|
O'Dey DM, Prescher A, Pallua N. Ein anatomischer Ansatz zur Durchblutungsverbesserung des Mamillen-Areola-Komplexes am Beispiel der vertikalen Mammareduktion. HANDCHIR MIKROCHIR P 2006; 38:370-7. [PMID: 17219320 DOI: 10.1055/s-2006-955939] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
Abstract
AIM This anatomic study is intended to point out the most regular and reproducible vessels supplying the nipple-areola complex (NAC) for use in vertical mammaplasty. BACKGROUND The superior pedicle technique routinely performed within the context of vertical mammaplasty procedures bears some risk for vascular dependent complications of the NAC especially in large breasts. Concerning vasculature, the supposedly most eligible pedicle to use should meet equally the best vascular requirements and technical demands necessary for maintaining both viability of the NAC and plasticity of the entire breast tissue. METHODS Based on an anatomic microdissection study of the thoracic vessel system of seven female corpses, a modification of the superior pedicle approach to carry the NAC was anatomically evaluated and tailored to vertical mammaplasty performed in the L-technique. RESULTS Out of six vascular sources responsible for the blood supply to the breast the branches originating from the lateral thoracic artery and concomitant veins appeared to reflect the major source of blood supply to the NAC due to their regularity and reproducibility. Especially the full-thickness glandular-dermal superolaterally-based pedicle should safely enclose these dominant branches, as well as supplementary vessels deriving from minor important sources in this region, while keeping plasticity of the vertically reduced breast. CONCLUSION The superolaterally-based full-thickness glandular-dermal pedicle mobilized epipectorally to carry the NAC proves to be anatomically a safe and reliable procedure eligible as an integral part of vertical mammaplasty.
Collapse
Affiliation(s)
- D M O'Dey
- Klinik für Plastische Chirurgie, Hand- und Verbrennungschirurgie, Universitätsklinik RWTH Aachen.
| | | | | |
Collapse
|
25
|
Abstract
The anatomy of the lateral cervical region is described and revisited. The three topographical regions where the neurovascular bundle can be easily compressed by surrounding structures are highlighted. Furthermore, the paper focuses on the anatomical variations which are able to produce a thoracic outlet syndrome (TOS).
Collapse
Affiliation(s)
- A Prescher
- Institut für Neuroanatomie, Medizinische Fakultät der RWTH Aachen.
| | | |
Collapse
|
26
|
von Lüdinghausen M, Fahr M, Prescher A, Schindler G, Kenn W, Weiglein A, Yoshimura K, Kageyama I, Kobayashi K, Tsuchimochi M. Accessory joints between basiocciput and atlas/axis in the median plane. Clin Anat 2005; 18:558-71. [PMID: 16092124 DOI: 10.1002/ca.20103] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
To explore the many osseous irregularities that are found in the area between the basiocciput, the anterior arch of the atlas and the tip of the dens axis we studied 99 cadaver specimens using magnetic resonance tomography (MRT), computed tomography (CT), median saw-cut sections, and histological sections. Additionally, "dry" specimens of the skull (n = 110), atlas (n = 56), and axis (n = 33) were investigated. In the median plane, the dry and cadaver specimens exhibited osteoarthritis-related osseous outgrowths and osteophytes of the articular surfaces of the median atlanto-axial joint (n = 63), and the presence of congenitally developed free ossicles (n = 22) and of third occipital condyles (n = 3). The largest osteophytes (giant osteophytes) (n = 4) of the anterior arch of the atlas formed osseous contact zones with the basiocciput that were visible histologically as real joints and were designated accessory median atlanto-occipital joints. The third occipital condyles also formed osseous contact zones, visible histologically as real joints, with the anterior arch of the atlas or with the tip of the dens, and were designated accessory atlanto-occipital or occipito-odontoid joints. Frequent free ossicles, incorporated into the accessory joint, were found by histological examination to be covered with hyaline cartilage.
Collapse
Affiliation(s)
- M von Lüdinghausen
- Institute of Anatomy and Cell Biology, University of Würzburg, Würzburg, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Draf W, Prescher A, Steigerwald C, Bockmühl U. The Cervicopterygoidal Approach to the Central Skull Base. Skull Base 2005. [DOI: 10.1055/s-2005-916509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
28
|
Spangenberg P, Prescher A. Boundaries of the Cleavage Plane between the Temporal Dura Stratum Meningeale and Periostale. Skull Base 2005. [DOI: 10.1055/s-2005-916547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
29
|
Ohnsorge JAK, Siebert CH, Schkommodau E, Mahnken AH, Prescher A, Weisskopf M. [Minimally-invasive computer-assisted fluoroscopic navigation for kyphoplasty]. Z Orthop Ihre Grenzgeb 2005; 143:195-203. [PMID: 15849639 DOI: 10.1055/s-2005-836514] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
AIM The transpedicular placement of a hollow needle into vertebral bodies for kyphoplasty requires utmost accuracy and thereby permanent multiplanar X-ray control. Facing the increasing number of vertebral compression fractures, the aim of this work was the implementation of computer-assistance to optimise the issue. Prior to clinical implementation, experimental trials were undertaken to analyse the quality-improving options of the technique. METHOD The virtual image of the planning and the puncture were correlated with the postoperative X-ray image of the needle. The real canal in the bone was then correlated with the preoperative planning in a CT-based 3D model and differences were calculated. As a measure of accuracy the deviation of the needle from the ideal intruding vector and the distance between its top and the centre of a predefined target were scrutinised and related to the indications of the navigation system. Operating time, radiation exposure and general applicability were additionally assessed. All data were compared with those of a conventional control group. RESULTS Planning and navigation could be executed with high accuracy. With an exactly transpedicular approach, neural structures were safely circumnavigated without once missing the target. In the control group the distance fault was up to 9 mm. The navigated drilling differed from the ideal trajectory by 1 degrees to max. 4 degrees. Conventional C-arm control led to a divergence of 4 degrees to 8 degrees . Radiation exposure could be reduced through computer assistance by 76 % to a fourth of the conventionally resulting amount and the pure operating time thereby decreased by 40 %. The inconvenient course of repeated positioning of the C-arm was overcome. CONCLUSION In challenging cases of deteriorated anatomy and difficult radiomorphologic orientation, especially of the lower thoracic spine, the CAOS-procedure succeeds in finding the optimal pedicular approach to the vertebral body, helps to avoid collateral damage and minimises the overall risk of the procedure. High accuracy and reduced radiation exposure justify the clinical use of fluoroscopic navigation for transpedicular instrumentation.
Collapse
|
30
|
Abstract
BACKGROUND Rhinogenous brain abscesses usually originate from a frontal sinusitis, rarely from the ethmoidal system or the maxillary sinus. However, there are different pathways that can lead to the transfer of a maxillary infection to the endocranial compartment. PATIENT A patient with frontal brain abscesses originating from a maxillary sinus infection is presented and diagnostic steps, therapy as well as pathophysiology are discussed. PATHOPHYSIOLOGY The venous plexus of the maxillary sinus drains through the posterior wall of the antrum of Highmore into the deep facial vein that leads into the pterygoid plexus and then through the rete foraminis ovalis into the cavernous sinus. In addition, numerous small veins perforate the osseous roof of the maxillary sinus and enter the orbit joining the superior or inferior ophthalmic vein. They are also connected to the cavernous sinus or the pterygoid plexus. A number of veins perforate the anterior wall of the maxillary sinus communicating with the angular vein that drains into the superior ophthalmic vein and into the cavernous sinus. From the cavernous sinus, the blood arrives at the deep middle cerebral vein that usually communicates through the white substance towards the brain's superficial venous system. CONCLUSION The presence of these maxillo-cerebral venous anastomoses explains the spread of infection from the maxillary sinus to the white substance of the brain without any direct association with the base of the skull.
Collapse
Affiliation(s)
- S Dazert
- Universitäts-HNO-Klinik Essen, Universität Duisburg-Essen.
| | | | | | | | | |
Collapse
|
31
|
Abstract
Divergent descriptions of the anatomic location and biomechanical function of the iliotibial tract (IT) can be found in the literature. This study attempted to obtain exact data regarding the anatomic course and material characteristics including the biomechanical properties of this structure. The following were its aims: (1) anatomical investigations of the IT; (2) mechanical properties of the IT; (3) femoral head centralizing force of the IT and subligamentous forces in the height of the greater trochanter in different joint positions by using a custom-made measuring prosthesis and a subligamentous positioned sensor; (4) construction of a finite element model of the proximal femur including the IT and measuring the femoral neck angle under variation. The hip joints and IT in a total of 18 unfixed corpses were evaluated. We studied the anatomic relationship to surrounding structures, as well as the material properties with the help of tensile strength testing utilizing an uniaxial apparatus. During the test, a load-displacement curve was registered, documenting the maximum load and deformation of the IT. To measure the subligamentous pressure at the height of the greater trochanter, a custom-made sensor with a power-recording instrument was constructed. Furthermore, an altered hip prosthesis with a pressure gauge at the height of the femoral neck was used to measure the forces which are directed at the acetabulum. The investigations were done in neutral-0 position and ab/adduction of the hip joint of the unfixed corpse. In addition, we varied the femoral neck angle between 115 degrees and 155 degrees in 5 degrees steps. To confirm the subligamentous forces, we did the same measurements intraoperatively at the height of the greater trochanter before and after hip joint replacement in 12 patients. We constructed a finite element model of the proximal femur and considering the IT. The acquisition of the data was done at physiological (128 degrees), varus (115 degrees), and valgus (155 degrees) femoral neck angles. The influencing forces of the IT at the height of the greater trochanter and the forces at the femoral head or the acetabulum could be measured. Our anatomical investigations revealed a splitting of the IT into a superficial and a deep portion, which covers the tensor fasciae latae. The tensor fasciae latae has an insertion on the IT. The IT continues down the femur, passing over the greater trochanter without developing an actual fixation to the bone. Part of the insertion of the gluteus maximus radiates into the IT. The IT passes over the vastus lateralis and inserts at the infracondylar tubercle of the tibia or Gerdy's tubercle, at the head of the fibula, as well as at the lateral intermuscular septum. Portions also insert on the transverse and longitudinal retinaculum of the patella. Concerning the material properties of the IT, we found a structural stiffness of 17 N/mm extension on average (D = 17 N/mm). The subligamentous measurements at the height of the greater trochanter in the unfixed corpse and intraoperatively during hip joint replacement showed an increase of the forces during adduction and a decrease during abduction of the hip joint. We found thereby a maximum increase up to 106 N with 40 degrees adduction. Concerning the femoral neck angle, we can state that valgus leads to lower subligamentous forces and varus to higher subligamentous forces. The forces directed at the acetabulum, which were measured by the prosthesis with a sensor along the femoral neck, showed a decrease with varus angles and an increase with valgus angles. The highest force of 624 N was measured with 40 degrees adduction and an angle of 155 degrees. The finite element model of the proximal femur showed a sole hip joint-centralizing force of the IT of 655 N with a femoral neck angle of 128 degrees after subtraction of the gluteal muscle force and the body weight. At 115 degrees, we found an increase up to 997 N and a decrease to 438 N at 155 degrees. Concerning the resulting forces in the acetabulum, we found opposite forces in comparison with the force of the IT at the height of the greater trochanter: at 115 degrees, a femoral head-centralizing force of 1601 N; at 128 degrees, 2360 N; and at 155 degrees, 2422 N. By our investigations, we can approximately prove the hip joint-centralizing force of the IT. By variation of the femoral neck angle and the position of the hip joint, we can predict the subligamentous force of the IT and the resulting force at the femoral head or at the acetabulum. The intraoperative measurement of the subligamentous forces of the IT is a good monitoring mechanism for the persistent hip-centralizing function of the IT in the course of hip joint replacement. The surgeon has the opportunity to check the stability of the hip joint after replacement. The finite element model gives the opportunity to check the divergent relative strength by variation of the femoral neck angle and the tension of the IT. In this way, the changes in the forces induced by a displacement osteotomy could be estimated preoperatively.
Collapse
Affiliation(s)
- K Birnbaum
- Orthopedic Department, Technical University Aachen, Pauwelsstrasse 30, 52074 Aachen, Germany.
| | | | | | | | | | | |
Collapse
|
32
|
Abstract
This anatomical study investigated the connection of the muscles of the abdominal wall to the transversalis fascia in the groin. In six unfixed male corpses we prepared the single levels of the inguinal abdominal wall and examined their interrelationships. Of special interest were the direction of the force vectors determined by the direction of the muscular fibers in relation to the transversalis fascia. We found no confirmation of a direct connection between the muscles of the abdominal wall and the transversalis fascia in the inguinal region. No force vector of the different muscular layers points away from the triangle of Hesselbach. By contraction each muscle thus relaxes the transversalis fascia of the Hesselbach triangle.
Collapse
Affiliation(s)
- C Peiper
- Surgical Clinic, Evangelisches Krankenhaus Witten, Pferdebachstrasse 27, 58455 Witten, Germany.
| | | | | | | | | |
Collapse
|
33
|
Conze J, Prescher A, Kisielinski K, Klinge U, Schumpelick V. Technical consideration for subxiphoidal incisional hernia repair. Hernia 2004; 9:84-7. [PMID: 15257447 DOI: 10.1007/s10029-004-0239-0] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2003] [Accepted: 04/15/2004] [Indexed: 10/26/2022]
Abstract
BACKGROUND The main principle of incisional hernia repair with mesh augmentation is a wide overlap of at least 5 cm in all directions. This is complicated when cartilaginous or osseous structures border the fascial defect, most notably at the xiphoid after sternotomy or in large proximal incisional hernias. METHOD We performed an anatomic investigation of this "problematic" area with its different structures and layers that form the retroxiphoidal space. RESULTS AND CONCLUSION The posterior lamina of the rectus sheath inserts on the posterior side of the xiphoid. This lamina inhibits a sufficient mesh placement. By sharp dissection dorsal the xiphoid process, the posterior lamina of the rectus sheath can be detached. This way the retroxiphoidal space can be opened. Further development of this space can be made by blunt dissection. In some cases, with retroxiphoidal scar formation after sternotomy, a sharp dissection might be necessary. This enables a combined retromuscular-retroxiphoid mesh augmentation repair with a sufficient underlay of at least 5 cm, according to the principles of sublay technique.
Collapse
Affiliation(s)
- J Conze
- Surgical Department and Institute for Anatomy, Rhenish Westphalian Technical University, Pauwelsstrasse 30, 52074 Aachen, Germany.
| | | | | | | | | |
Collapse
|
34
|
O'Dey DM, Heimburg DV, Prescher A, Pallua N. The arterial vascularisation of the abdominal wall with special regard to the umbilicus. ACTA ACUST UNITED AC 2004; 57:392-7. [PMID: 15191818 DOI: 10.1016/j.bjps.2004.02.008] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2003] [Accepted: 02/17/2004] [Indexed: 11/19/2022]
Abstract
AIM In order to prevent wound healing problems around the transposed umbilicus following abdominoplasty, we investigated the arterial vascularisation of the abdominal wall with special regard to the umbilicus. The aim was to optimise the planning of the umbilical stalk and flap design. METHOD The inferior and superior epigastric arteries of 12 cadavers (mean age 83 years) were injected with barium-sulphate, lead-mennige and gelatine. The abdominal walls were resected en bloc and X-ray photographs were taken by conventional and mammographic technique. RESULTS The radiographic examination showed that the main trunks of the epigastric vessels follow an "hour-glass" or "rhomboid" pattern around the centromedial umbilicus. Each main trunk splits into two obligate branches one medial and one lateral. The anastomosis between the inferior and superior epigastric artery is located above the umbilicus. The umbilicus is nourished by separate axial vessels originating from the inferior epigastric artery. It was also shown that the inferior intercostal arteries anastomose with the branches of the inferior and superior epigastric artery. CONCLUSION Dividing the abdominal wall into four quadrants around the central umbilicus, the lateral areas of the lower quadrants show the weakest vascularisation by the inferior epigastric artery. This fact may cause healing problems after surgery in this area. The axial vascularisation of the umbilicus makes any torsion or traction a potential hazard to the umbilical flap during abdominoplasty especially by re-siting the umbilicus. The anatomical study showed clearly the benefit of preparing a broad base fat layer with a generous diameter of incision line around the umbilicus.
Collapse
Affiliation(s)
- D M O'Dey
- Department of Plastic Surgery, Hand and Burn Surgery, University Hospital Aachen, Pauwelsstrasse 30, D-52057 Aachen, Germany.
| | | | | | | |
Collapse
|
35
|
Conze J, Prescher A, Klinge U, Saklak M, Schumpelick V. Pitfalls in retromuscular mesh repair for incisional hernia: The importance of the ?fatty triangle? Hernia 2004; 8:255-9. [PMID: 15185126 DOI: 10.1007/s10029-004-0235-4] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2003] [Accepted: 04/01/2004] [Indexed: 11/25/2022]
Abstract
Open retromuscular mesh repair has become a standard procedure in incisional hernia repair. This technique led to a significant decrease of recurrences. Recurrences after this technique typically occur at the upper mesh border and are a result of the technical complexity of reaching the postulated underlay of 5 cm in the region of the linea alba. We performed an anatomical study in human corpses to investigate the abdominal wall with its different structures, with emphasis on the overlap of the mesh under the linea alba. The overlap can be achieved by incision of the posterior lamina of the rectus sheath, on both sides close to the linea alba. The incision opens the preperitoneal space and appears in the shape of a "fatty triangle". The anterior lamina of the rectus sheath above the hernia defect remains intact and facilitates a sufficient thrust bearing for a retromuscular mesh implantation. Knowledge of the anatomy and preparation of the "fatty triangle" enables a mesh positioning according to the principles of retromuscular mesh repair.
Collapse
Affiliation(s)
- J Conze
- Surgical Department, Rhenish Westphalian Technical University, Pauwelsstrasse 30, 52074, Aachen, Germany.
| | | | | | | | | |
Collapse
|
36
|
Schälte G, van den Berg P, Beckers S, Bickenbach J, Prescher A, Kuhlen R. Der LaryVent™ – Entwicklung eines Prototypen zur laryngealen Maskenbeatmung. Anasthesiol Intensivmed Notfallmed Schmerzther 2004. [DOI: 10.1055/s-2004-828692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
37
|
Conze J, Krones CJ, Prescher A, Ulmer F, Kisielinski K, Schumpelick V. [Foreign body-induced disruption of the gastrointestinal tract-anatomy of the ileocoecal opening]. Chirurg 2004; 75:525-8. [PMID: 15141297 DOI: 10.1007/s00104-003-0789-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
INTRODUCTION Over 75% of ingested foreign bodies pass the gastrointestinal tract without any complications. Blunt foreign bodies may lead to a disruption of the intestinal passage, mainly in the area of the ileocoecal opening. The size of the reported foreign bodies varies considerably. The aim of this study was the anatomic investigation to clarify the possible causes of obstruction and its influence on the diameter of the ileocoecal opening. MATERIAL AND METHOD We investigate anatomically and describe the ileocoecal opening on the basis of 27 specimens. RESULTS We found not a flap mechanism but a valve mechanism in the ileocoecal junction. The median diameter of the formalin-fixated specimens was 10.9 mm respectively 21.8 mm according to an assumed correction factor of 2. The cause for intestinal obstruction most probably is the ingestion of blunt, angular foreign bodies in the ostium ileale. CONCLUSION The intraindividual differences as well as the considerable size of foreign bodies that pass the ileoceocal opening support the hypothesis, that the complications described are more a consequence of an ingestion of blunt, cornered foreign bodies in the ostium ileale independent ofn the size of the ileocoecal opening itself.
Collapse
Affiliation(s)
- J Conze
- Chirurgische Klinik und Poliklinik, RWTH Aachen.
| | | | | | | | | | | |
Collapse
|
38
|
Krombach GA, Schmitz-Rode T, Haage P, DiMartino E, Prescher A, Kinzel S, Günther RW. Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT. Neuroradiology 2004; 46:326-31. [PMID: 15024531 DOI: 10.1007/s00234-003-0948-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2002] [Accepted: 12/24/2002] [Indexed: 10/26/2022]
Abstract
We assessed the value of MRI for delineation of dehiscence of the superior or posterior semicircular canal, as compared with CT, the current standard study for this entity. We reviewed heavily T2-weighted fast spin-echo images and high-resolution CT of the temporal bones of 185 patients independently semicircular canal dehiscence and its extent. In 30 patients (19 men, 11 women) we identified dehiscence of the bone over the superior and/or posterior semicircular canal on MRI. In 27 of these cases CT also showed circumscribed bone defects. In one patient dehiscence of the superior semicircular canal was initially overlooked on MRI, but seen on CT. MRI imaging thus had a sensitivity of 96% and specificity of 98%. Knowledge of the appearances of this entity on MRI may contribute to early diagnosis in patients with vertigo due to semicircular canal dehiscence.
Collapse
Affiliation(s)
- G A Krombach
- Department of Diagnostic Radiology, University of Technology, Pauwelstrasse 30, 52057 Aachen, Germany.
| | | | | | | | | | | | | |
Collapse
|
39
|
Abstract
BACKGROUND Medial nasal fistulas are rare congenital malformations that mostly become obvious by recurrent infections such as secretion from the fistula opening or swelling of the nasal tissues. In rare cases, these fistulas may extend intracranially with meningeal irritations. PATIENT PRESENTATION Three patients with medial nasal fistulas were operated during the last two years in our department. In two children, the fistulas ended at the glabella. In one older boy, the fistula revealed an intracranial extension. In the last case, a combined rhino- and neurosurgical approach was applied to perform a complete resection of the fistula. DISCUSSION During the second embryonic month of facial development, the medial nasal processes approach each other with a fusion of their epithelial covering that completely disappears during later stages. If parts of this epithelial fusion zone persist, epithelial remnants may develop into nasal fistulas or dermoids. The adequate therapy of these nasal malformations consists of a complete surgical removal.
Collapse
Affiliation(s)
- S Dazert
- Universitätsklinik für Hals-Nasen-Ohrenheilkunde und Kopf- und Halschirurgie, Ruhr-Universität Bochum, St. Elisabeth-Hospital, Bochum, Germany.
| | | | | | | | | |
Collapse
|
40
|
Dazert S, Sivec D, Radü HJ, Schönweiler R, Prescher A. Untersuchungen zum Pathomechanismus der Aryknorpelluxation. Laryngorhinootologie 2004. [DOI: 10.1055/s-2004-823351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
41
|
Bertram C, Prescher A, Fürderer S, Eysel P. Anheftungspunkte des Lig. longitudinale posterius und deren Bedeutung f�r Wirbelk�rperfrakturen. Der Orthop�de 2003; 32:848-51. [PMID: 14579015 DOI: 10.1007/s00132-003-0529-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Spine fractures with damage of the posterior wall of the vertebra often can be anatomically reconstructed by indirect reduction. Whether the posterior longitudinal ligament (PLL) is responsible for the reduction is still subject to debate. The aim of our investigation was to ascertain the role of the PLL in closed reduction of spine fractures by identifying the bony attachment points of this ligament. We performed a gross anatomical dissection, a light- and polarized microscopic investigation on 22 human cadaverous thoracic and lumbar spines to determine the points of attachment of the PLL. We found two layers of the PLL. The superficial layer runs from the first thoracic down to the third lumbar vertebra with a width of 0.4-1.0 cm and from there descends as a thin rudiment to the sacrum. The deep layer shows a segmental rhomboid structure. Lateral fibers are attached to the annulus fibrosus and at the rim of the adjacent vertebrae. Medial fibers are attached additionally to the posterior wall of the vertebral bodies by bridging the foramina basivertebralia. Since these foramina become enlarged in the caudal parts of the vertebral column, the number of attachment points at the posterior wall of the vertebral bodies decreases caudally. Good results for reconstruction of the posterior wall in vertebral fractures of the thoracic and upper lumbar spine can be explained by the anatomical situation of the PLL and stress the important role of the PLL in indirect reduction of spine fractures.
Collapse
Affiliation(s)
- C Bertram
- Klinik und Poliklinik für Orthopädie, Universität, Cologne.
| | | | | | | |
Collapse
|
42
|
Conze J, Krones CJ, Prescher A, Schumpelick V. [Partial intestinal obstruction after swallowing a self-expanding sponge for weight reduction]. Dtsch Med Wochenschr 2003; 128:1706-8. [PMID: 12920668 DOI: 10.1055/s-2003-41337] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
HISTORY AND ADMISSION FINDINGS A 21-year-old woman presented with predominantly right-sided cramp-like abdominal pain which had started the previous day. The abdomen was soft on palpation, the peristaltic sounds increased. Body temperature was normal. INVESTIGATIONS Routine laboratory tests were unremarkable, including white cell count (4.5 G/l). and C-reactive protein. TREATMENT AND COURSE She was admitted to hospital for observation. Because the symptoms persisted she underwent a right lower laparotomy because acute appendicitis was suspected. Intraperitoneal examination of the intestines revealed a soft, sponge-like foreign body just above the ileocecal valve. The overlying ileum was incised and a sponge removed. Postoperatively the patient reported having taken 4 capsules of CM3, a weight-reducing preparation, about 14 days ago. These capsules dissolve in the stomach and each releases a small sponge which expands and mechanically induces a feeling of satiation. The further course was unremarkable and she was discharged on the 8th postoperative day. CONCLUSION When producing weight-reducing preparations that act according to physico-mechanical principles, anatomical circumstances should be considered, and they should only be taken under medical supervision.
Collapse
Affiliation(s)
- J Conze
- Chirurgische Klinik und Poliklinik, Rheinisch Westfälischen Technischen Hochshule, Aachen.
| | | | | | | |
Collapse
|
43
|
Ohnsorge JAK, Portheine F, Mahnken AH, Prescher A, Wirtz DC, Siebert CH. [Computer-assisted retrograde drilling of osteochondritic lesions of the talus with the help of fluoroscopic navigation]. Z Orthop Ihre Grenzgeb 2003; 141:452-8. [PMID: 12929004 DOI: 10.1055/s-2003-41558] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
AIM Due to the narrow access to the talar dome and the proximity of osteochondritic lesions to the joint surface, the therapeutic retrograde drilling often requires multiple attempts and repeated intraoperative X-ray-control. The advantages of a fluoroscopy-based computer-assisted navigation system regarding efficient planning and easy performance of the ideal drill path are evaluated in respect to accuracy and radiation exposure, as well as to time requirements. METHOD A 5 mm spherical target was subcortically implanted in the medial aspect of the talar dome of 16 human cadaver specimens. Free-hand drilling was performed using the FluoroNav TM system in one group and conventional repetitive C-arm control in the other. The computed evaluation of the operative results was realized in a CT-generated 3D-model with the help of the DISOS planning and calculation program. The distance of the tip of the drill to the center of the lesion was measured, as well as X-ray exposure and total operating time. RESULTS The CAS procedure missed the lesion only once. The mean deviation of the computer-guided drill path was measured to be 2 mm, whereas the conventional method led to a mean distance of 5 mm from the target. Conventional drilling failed to reach the target in 5 cases, violating the articular cartilage twice. Navigation reduced the traditionally required multiple attempts of the intervention to just one drill canal and reduced radiation time to 25 %. Despite the increased technical preparation required, the navigated procedure only exceeded the conventional operating time by 2 minutes. CONCLUSION Thanks to the significantly increased accuracy, fluoroscopic navigation offers a high degree of safety and efficacy for this minimally invasive procedure. The operation can easily be performed successfully causing only minimal collateral damage to the bone, preserving the joint surface. The inherent risks of the retrograde drilling of osteochondritic lesions are lower with navigation, while the radiation exposure of the patient and the staff is significantly reduced.
Collapse
|
44
|
Krombach GA, DiMartino E, Schmitz-Rode T, Prescher A, Haage P, Kinzel S, Günther RW. Posterior semicircular canal dehiscence: a morphologic cause of vertigo similar to superior semicircular canal dehiscence. Eur Radiol 2003; 13:1444-50. [PMID: 12764665 DOI: 10.1007/s00330-003-1828-5] [Citation(s) in RCA: 66] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2002] [Revised: 12/04/2002] [Accepted: 01/02/2003] [Indexed: 11/30/2022]
Abstract
The aim of this study was to assess imaging findings of posterior semicircular dehiscence on computed tomography and to evaluate incidence of posterior and superior semicircular canal dehiscence in patients presenting with vertigo, sensorineuronal hearing loss or in a control group without symptoms related to the inner ear. Computed tomography was performed in 507 patients presenting either with vertigo ( n=128; 23 of these patients suffered also from sensorineuronal hearing loss), other symptoms related to the inner ear, such as hearing loss or tinnitus ( n=183) or symptoms unrelated to the labyrinth ( n=196). All images were reviewed for presence of dehiscence of the bone, overlying the semicircular canals. Twenty-nine patients had superior semicircular canal dehiscence. Of these patients, 83% presented with vertigo, 10% with hearing loss or tinnitus and the remaining 7% with symptoms unrelated to the inner ear. In 23 patients dehiscence of the posterior semicircular canal was encountered. Of these patients, 86% presented with vertigo, 9% with hearing loss or tinnitus and 5% with symptoms unrelated to the inner ear. Defects of the bony overly are found at the posterior semicircular canal, in addition to the recently introduced superior canal dehiscence syndrome. Significant prevalence of vertigo in these patients suggests that posterior semicircular canal dehiscence can cause vertigo, similar to superior semicircular canal dehiscence.
Collapse
Affiliation(s)
- G A Krombach
- Department of Diagnostic Radiology, University of Technology, Pauwelstrasse 30, 52057, Aachen, Germany.
| | | | | | | | | | | | | |
Collapse
|
45
|
Ohnsorge JAK, Schkommodau E, Wirtz DC, Wildberger JE, Prescher A, Siebert CH. [Accuracy of fluoroscopically navigated drilling procedures at the hip]. Z Orthop Ihre Grenzgeb 2003; 141:112-9. [PMID: 12605340 DOI: 10.1055/s-2003-37305] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
AIM Many orthopaedic procedures require an accurate drilling in bone. The outcome is frequently dependent on the geometric accuracy of this surgical step. The precision of such a procedure can be improved with the help of fluoroscopic navigation. Reliability, accuracy and benefit of this new method for the patient, as well as for the surgical staff, need to be analysed. METHOD In a standardised in vitro trial, the drilling of a 5 mm spherical lesion implanted in an artificial femoral head was performed using a navigated drill-guide and a navigated drill. In groups A and B, the distance of the tip of the drill to the center of the lesion was analysed in a 3D CT-generated model and in macroscopic cross section. Additionally, in group B the actual direction of the drill canal was measured. RESULTS The mean distance in group A was measured to be 1 mm, with all results ranging between 0 and 2.5 mm. In group B the planned direction of the canal was reproduced with a deviation of 0 degrees to 7 degrees, the target only being missed by a mean distance of 2.5 mm and a maximum of 3.5 mm. Compared to the macroscopic and 3D-CT findings, the correlation of the data calculated by the navigation system was accurate up to a difference of 4 degrees or 2 mm. CONCLUSION The fluoroscopically assisted freehand navigation used during the drilling of bone led to a high accuracy of three-dimensional tip placement while reducing radiation exposure to a minimum. It represents a promising and efficient application for a variety of procedures in orthopaedic surgery.
Collapse
|
46
|
Krombach GA, Schmitz-Rode T, Prescher A, DiMartino E, Weidner J, Günther RW. The petromastoid canal on computed tomography. Eur Radiol 2002; 12:2770-5. [PMID: 12386772 DOI: 10.1007/s00330-002-1306-5] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2001] [Revised: 11/22/2001] [Accepted: 12/03/2001] [Indexed: 10/25/2022]
Abstract
The objective was to assess visibility and anatomy of the petromastoid canal in high-resolution CT. Computed tomography images of 188 patients were reviewed for delineation of the petromastoid canal. This bony canal connects the mastoid antrum with the cranial cavity and houses the subarcuate artery and vein. The diameter, obtained in the middle portion of the canal, was compared with the diameter of the vestibular and cochlear aqueduct in all patients, and absolute values measured in 20 cases. Collimation was 1 mm in 164 and 2 mm in 24 examinations. Additionally, temporal bone of a cadaver was imaged and microdissected. The petromastoid canal was identified bilaterally in all 164 scans that were obtained with a slice thickness of 1 mm. In 5 of the 24 patients imaged with a collimation of 2 mm, the canal was not visible, most probably due to partial-volume effects. The petromastoid canal had the same diameter as the cochlear aqueduct in 42/44 (right/left), exceeded it in 66/61 and was smaller in 75/78 cases. In comparison to the vestibular aqueduct it had an equal diameter in 38/41 (right/left), exceeded it in 63/61, and was rated as smaller in 82/81 temporal bones. Diameters for the canals were: petromastoid canal 0.51+/-0.04 mm; cochlear aqueduct 0.57+/-0.03; and vestibular aqueduct 0.63+/-0.06 mm. Microdissection of the specimen revealed the entire course of the canal and demonstrated a similar appearance of the structure as in the images. The petromastoid canal can easily be identified on high-resolution, thin-slice CT images. Knowledge of the anatomy of this bony canal prevents misinterpretation as pathological structure, such as fracture line, which might occur if this structure is not known.
Collapse
Affiliation(s)
- G A Krombach
- Department of Diagnostic Radiology, University of Technology, Pauwelstrasse 30, 52057 Aachen, Germany.
| | | | | | | | | | | |
Collapse
|
47
|
Kisielinski K, Willis S, Prescher A, Klosterhalfen B, Schumpelick V. A simple new method to calculate small intestine absorptive surface in the rat. Clin Exp Med 2002; 2:131-5. [PMID: 12447610 DOI: 10.1007/s102380200018] [Citation(s) in RCA: 131] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The rat is an established model for studying intestinal adaptations following abdominal surgery. In the study of functional and morphological adaptations of the small intestine, it is helpful to estimate the mucosal surface area. In order to simplify measurements and calculation we developed a new mathematical model for calculation of the mucosal surface area on histological sections. In contrast to other methods, it requires only cross-sections of small intestine and includes the measurement of only three histological parameters: length and width of villus and width of crypt. The new approach was compared with the most commonly used procedures, the Harris and the Fisher-Parsons methods, under experimental conditions. An animal study including single-pass perfusion, fixation, staining and subsequent histomorphometry of jejunum and ileum using these different methods was performed. The new method showed the least work and presented no significant differences compared with the precise Harris method. In conclusion, the method described is an adequate tool to estimate the mucosal surface area with less work and with comparable results to established methods. The less-complex method may be a valuable tool in experimental research of small intestine adaptations in rats.
Collapse
Affiliation(s)
- K Kisielinski
- Department of Surgery, University Hospital Aachen, Germany, Pauwelsstrasse 30, 52074 Aachen, Germany.
| | | | | | | | | |
Collapse
|
48
|
Abstract
BACKGROUND Even though numerous theories have speculated either on the vascular or fibrous tumour component as tissue of origin, aetiology of angiofibroma still remain unclear. Histological investigations recently led Beham and coworkers to the assumption that angiofibromas have to be considered as vascular malformations. METHODS After giving a literature review of the various theories on tumour origin the proposal to consider angiofibromas as vascular malformations is discussed on an embryological base. Taking typical clinical features of the tumour and knowledge of vasculogenesis into account a new explanation for origin of the vascular tumour component is presented. RESULTS The vascular component of angiofibromas can be explained embryologically due to incomplete regression of the first branchial arch artery (vascular atavism). This vessel arises regularly between embryological day 22 and 24 and recedes during regular development completely until delivery via temporary formation of a vascular plexus. In the late stages of embryological development remnants of the plexus are found at the area of the sphenopalatine foramen, the typical site of angiofibroma origin. Incomplete regression of the vascular plexus of the former first branchial arch artery may form the vascular component of an angiofibroma arising due to growth stimulation at the time of adolescents. CONCLUSIONS Incomplete regression of the first branchial arch artery presenting an atavism is suited to explain the vascular tumour component of angiofibromas considering main tumour characteristics (origin in the posterior nasal cavity close to the sphenopalatine foramen, main blood supply from the maxillary artery with possible feeders arising from the internal carotid artery). Our embryological contributions support to define angiofibromas as vascular malformations.
Collapse
Affiliation(s)
- B Schick
- Klinik für HNO-Krankheiten, Kopf- und Halschirurgie, Universitätskliniken des Saarlandes, Homburg/Saar.
| | | | | |
Collapse
|
49
|
Abstract
The case of an 87-year old man with widespread prostatic cancer is reported. During the autopsy macroscopically visible metastases were found within the frontal sinuses. These tumor masses destroyed the posterior osseous wall of the frontal sinus and formed polypoid bulging masses. In contrast to the macroscopically unaffected mucous membrane of the sphenoid sinus the maceration specimen of the skull base demonstrated a spongious-mossy, osteoplastic metastasis, lining the sphenoid sinus like a tapestry. This affection started from an exhaustive osteoplastic metastasis within the clivus. No metastases could be found in both antrums or the ethmoids. Retrospectively no symptoms from the paranasal sinuses could be eruated, only occasional pain of the frontal bone. The review of the world literature with 123 reports revealed 169 cases. Renal cell carcinomas most frequently metastasize into the paranasal sinuses (67 cases), followed by bronchogenic carcinomas (15 cases). Thyroid cancers and cancers of the mammary gland are responsible for 13 respectively 14 cases. The prostate also adds 12 cases. The paranasal sinuses are affected in diminishing frequency: maxillary sinus (55 cases), sphenoid sinus (37 cases), ethmoidal cells (23 cases) and frontal sinus (15 cases). In 38 cases exhaustive metastases affecting two or more paranasal sinuses are reported. The statement of literature, that metastases affecting the paranasal sinuses are much more frequent than reported, cannot be supported by our study, because the intensive autoptic investigation of 50 skulls of patients suffering from widespread cancers revealed no further cases of metastatic processes of the paranasal sinuses.
Collapse
Affiliation(s)
- A Prescher
- Institut für Anatomie I, Universitätsklinikum der RWTH Aachen, Aachen
| | | |
Collapse
|
50
|
Wirtz D, Sellei RM, Portheine F, Prescher A, Weber M. [Effect of femoral intramedullary irrigation on periprosthetic cement distribution: jet lavage versus syringe lavage]. Z Orthop Ihre Grenzgeb 2001; 139:410-4. [PMID: 11605292 DOI: 10.1055/s-2001-17983] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
INTRODUCTION The purpose of this experimental study was to determine quantitatively the cement penetration into periprosthetic femoral bone by Icomparing the use of jet-lavage with the conventional syringe irrigation. METHODS 10 pairs of fresh-frozen human cadaver femora were used for cemented stem implantation, The left femora were irrigated with a syringe device, the right femora with a jet-lavage system. After implantation, all femora were cut into 5-mm slices from proximal to distal with a diamond saw. The scanned slices were analysed using an image processing system which provided a discrimination between implant, cement, and bone as well as an exact determination of the cement area. RESULTS In all 10 femora, a recognizable improvement of the cement penetration into the periprosthetic bone was demonstrated using the jet-lavage. In the proximal part, the mean cement penetration was 8.6% higher in the jet-lavage group than in the syringe device group. An equivalent tendency towards the jet-lavage pretreated femora was seen in the middle part with 8.7% on average mean and in the distal part with 6.4% on average. Also, when subdividing the periprosthetic area into 4 quadrants, a significant improvement of the cement penetration was found with the exception of the ventro-medial region. CONCLUSION Cement distribution and penetration is improved using the jet-lavage technique for cleaning the medullary canal of the femur. Therefore, the jet-lavage should be used as a standard procedure in clinical cementing techniques.
Collapse
Affiliation(s)
- D Wirtz
- Orthopädische Universitätsklinik der RWTH Aachen.
| | | | | | | | | |
Collapse
|