1
|
Kupratis ME, Gonzalez U, Rahman A, Burris DL, Corbin EA, Price C. Exogenous Collagen Crosslinking is Highly Detrimental to Articular Cartilage Lubrication. J Biomech Eng 2024; 146:071001. [PMID: 38323667 PMCID: PMC11005859 DOI: 10.1115/1.4064663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 01/29/2024] [Accepted: 01/30/2024] [Indexed: 02/08/2024]
Abstract
Healthy articular cartilage is a remarkable bearing material optimized for near-frictionless joint articulation. Because its limited self-repair capacity renders it susceptible to osteoarthritis (OA), approaches to reinforce or rebuild degenerative cartilage are of significant interest. While exogenous collagen crosslinking (CXL) treatments improve cartilage's mechanical properties and increase its resistance to enzymatic degradation, their effects on cartilage lubrication remain less clear. Here, we examined how the collagen crosslinking agents genipin (GP) and glutaraldehyde (GTA) impact cartilage lubrication using the convergent stationary contact area (cSCA) configuration. Unlike classical configurations, the cSCA sustains biofidelic kinetic friction coefficients (μk) via superposition of interstitial and hydrodynamic pressurization (i.e., tribological rehydration). As expected, glutaraldehyde- and genipin-mediated CXL increased cartilage's tensile and compressive moduli. Although net tribological rehydration was retained after CXL, GP or GTA treatment drastically elevated μk. Both healthy and "OA-like" cartilage (generated via enzymatic digestion) sustained remarkably low μk in saline- (≤0.02) and synovial fluid-lubricated contacts (≤0.006). After CXL, μk increased up to 30-fold, reaching values associated with marked chondrocyte death in vitro. These results demonstrate that mechanical properties (i.e., stiffness) are necessary, but not sufficient, metrics of cartilage function. Furthermore, the marked impairment in lubrication suggests that CXL-mediated stiffening is ill-suited to cartilage preservation or joint resurfacing.
Collapse
Affiliation(s)
- Meghan E. Kupratis
- Biomedical Engineering, University of Delaware, Newark, DE 19713
- University of Delaware
| | - Uriel Gonzalez
- Biomedical Engineering, University of Delaware, Newark, DE 19713
- University of Delaware
| | - Atia Rahman
- Mechanical Engineering, University of Delaware, Newark, DE 19713
- University of Delaware
| | - David L. Burris
- Mechanical Engineering, University of Delaware, Newark, DE 19716
| | - Elise A. Corbin
- Biomedical Engineering, University of Delaware, Newark, DE 19713; Materials Science & Engineering, University of Delaware, Newark, DE 19716
- University of Delaware
| | - Christopher Price
- Biomedical Engineering, University of Delaware, Newark, DE 19713; Mechanical Engineering, University of Delaware, Newark, DE 19716
| |
Collapse
|
2
|
Kupratis ME, Rahman A, Burris DL, Corbin EA, Price C. Enzymatic digestion does not compromise sliding-mediated cartilage lubrication. Acta Biomater 2024; 178:196-207. [PMID: 38428511 DOI: 10.1016/j.actbio.2024.02.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 02/21/2024] [Accepted: 02/23/2024] [Indexed: 03/03/2024]
Abstract
Articular cartilage's remarkable low-friction properties are essential to joint function. In osteoarthritis (OA), cartilage degeneration (e.g., proteoglycan loss and collagen damage) decreases tissue modulus and increases permeability. Although these changes impair lubrication in fully depressurized and slowly slid cartilage, new evidence suggests such relationships may not hold under biofidelic sliding conditions more representative of those encountered in vivo. Our recent studies using the convergent stationary contact area (cSCA) configuration demonstrate that articulation (i.e., sliding) generates interfacial hydrodynamic pressures capable of replenishing cartilage interstitial fluid/pressure lost to compressive loading through a mechanism termed tribological rehydration. This fluid recovery sustains in vivo-like kinetic friction coefficients (µk<0.02 in PBS and <0.005 in synovial fluid) with little sensitivity to mechanical properties in healthy tissue. However, the tribomechanical function of compromised cartilage under biofidelic sliding conditions remains unknown. Here, we investigated the effects of OA-like changes in cartilage mechanical properties, modeled via enzymatic digestion of mature bovine cartilage, on its tribomechanical function during cSCA sliding. We found no differences in sliding-driven tribological rehydration behaviors or µk between naïve and digested cSCA cartilage (in PBS or synovial fluid). This suggests that OA-like cartilage retains sufficient functional properties to support naïve-like fluid recovery and lubrication under biofidelic sliding conditions. However, OA-like cartilage accumulated greater total tissue strains due to elevated strain accrual during initial load application. Together, these results suggest that elevated total tissue strains-as opposed to activity-mediated strains or friction-driven wear-might be the key biomechanical mediator of OA pathology in cartilage. STATEMENT OF SIGNIFICANCE: Osteoarthritis (OA) decreases cartilage's modulus and increases its permeability. While these changes compromise frictional performance in benchtop testing under low fluid load support (FLS) conditions, whether such observations hold under sliding conditions that better represent the joints' dynamic FLS conditions in vivo is unclear. Here, we leveraged biofidelic benchtop sliding experiments-that is, those mimicking joints' native sliding environment-to examine how OA-like changes in mechanical properties effect cartilage's natural lubrication. We found no differences in sliding-mediated fluid recovery or kinetic friction behaviors between naïve and OA-like cartilage. However, OA-like cartilage experienced greater strain accumulation during load application, suggesting that elevated tissue strains (not friction-driven wear) may be the primary biomechanical mediator of OA pathology.
Collapse
Affiliation(s)
| | - Atia Rahman
- Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - David L Burris
- Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - Elise A Corbin
- Biomedical Engineering, University of Delaware, Newark, DE, USA; Materials Science & Engineering, University of Delaware, Newark, DE, USA
| | - Christopher Price
- Biomedical Engineering, University of Delaware, Newark, DE, USA; Mechanical Engineering, University of Delaware, Newark, DE, USA.
| |
Collapse
|
3
|
Zou X, Zhang H, Benson JM, Gao H, Burris DL, Fox JM, Jia X. Modeling the Maturation of the Vocal Fold Lamina Propria Using a Bioorthogonally Tunable Hydrogel Platform. Adv Healthc Mater 2023; 12:e2301701. [PMID: 37530909 PMCID: PMC10834846 DOI: 10.1002/adhm.202301701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2023] [Revised: 07/10/2023] [Indexed: 08/03/2023]
Abstract
Toward the goal of establishing an engineered model of the vocal fold lamina propria (LP), mesenchymal stem cells (MSCs) are encapsulated in hyaluronic acid (HA)-based hydrogels employing tetrazine ligation with strained alkenes. To mimic matrix stiffening during LP maturation, diffusion-controlled interfacial bioorthogonal crosslinking is carried out on the soft cellular construct using HA modified with a ferocious dienophile, trans-cyclooctene (TCO). Cultures are maintained in MSC growth media for 14 days to afford a model of a newborn LP that is homogeneously soft (nLP), a homogeneously stiffened construct zero (sLP0) or 7 days (sLP7) post cell encapsulation, and a mature LP model (mLP) with a stiff top layer and a soft bottom layer. Installation of additional HA crosslinks restricts cell spreading. Compared to the nLP controls, sLP7 conditions upregulate the expression of fibrous matrix proteins (Col I, DCN, and FN EDA), classic fibroblastic markers (TNC, FAP, and FSP1), and matrix remodeling enzymes (MMP2, TIMP1, and HAS3). Day 7 stiffening also upregulates the catabolic activities, enhances ECM turnover, and promotes YAP expression. Overall, in situ delayed matrix stiffening promotes a fibroblast transition from MSCs and enhances YAP-regulated mechanosensing.
Collapse
Affiliation(s)
- Xiaoyu Zou
- Department of Materials Science and Engineering, University of Delaware, Newark, Delaware, USA
| | - He Zhang
- Department of Materials Science and Engineering, University of Delaware, Newark, Delaware, USA
| | - Jamie M. Benson
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware, USA
| | - Hanyuan Gao
- Department of Materials Science and Engineering, University of Delaware, Newark, Delaware, USA
| | - David L. Burris
- Department of Mechanical Engineering, University of Delaware, Newark, Delaware, USA
| | - Joseph. M. Fox
- Department of Materials Science and Engineering, University of Delaware, Newark, Delaware, USA
- Department of Chemistry and Biochemistry, University of Delaware, Newark, Delaware, USA
| | - Xinqiao Jia
- Department of Materials Science and Engineering, University of Delaware, Newark, Delaware, USA
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware, USA
- Delaware Biotechnology Institute, 590 Avenue 1743, Newark, Delaware, USA
| |
Collapse
|
4
|
Bomb K, Pradhan L, Zhang Q, Jarai BM, Bhattacharjee A, Burris DL, Kloxin AM, Fromen CA. Destructive fibrotic teamwork: how both microenvironment stiffness and profibrotic interleukin 13 impair alveolar macrophage phenotype and function. Biomater Sci 2022; 10:5689-5706. [PMID: 36018297 PMCID: PMC9632634 DOI: 10.1039/d2bm00828a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The pulmonary fibrotic microenvironment is characterized by increased stiffness of lung tissue and enhanced secretion of profibrotic soluble cues contributing to a feedback loop that leads to dysregulated wound healing and lung failure. Pinpointing the individual and tandem effects of profibrotic stimuli in impairing immune cell response remains difficult and is needed for improved therapeutic strategies. We utilized a statistical design of experiment (DOE) to investigate how microenvironment stiffness and interleukin 13 (IL13), a profibrotic soluble factor linked with disease severity, contribute to the impaired macrophage response commonly observed in pulmonary fibrosis. We used engineered bioinspired hydrogels of different stiffness, ranging from healthy to fibrotic lung tissue, and cultured murine alveolar macrophages (MH-S cells) with or without IL13 to quantify cell response and analyze independent and synergistic effects. We found that, while both stiffness and IL13 independently influence macrophage morphology, phenotype, phagocytosis and efferocytosis, these factors work synergistically to exacerbate impaired macrophage phenotype and efferocytosis. These unique findings provide insights into how macrophages in fibrotic conditions are not as effective in clearing debris, contributing to fibrosis initiation/progression, and more broadly inform how underlying drivers of fibrosis modulate immune cell response to facilitate therapeutic strategies.
Collapse
Affiliation(s)
- Kartik Bomb
- Chemical and Biomolecular Engineering, University of Delaware, Newark, DE, USA.
| | - Lina Pradhan
- Chemical and Biomolecular Engineering, University of Delaware, Newark, DE, USA.
| | - Qi Zhang
- Chemical and Biomolecular Engineering, University of Delaware, Newark, DE, USA.
| | - Bader M Jarai
- Chemical and Biomolecular Engineering, University of Delaware, Newark, DE, USA.
| | | | - David L Burris
- Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - April M Kloxin
- Chemical and Biomolecular Engineering, University of Delaware, Newark, DE, USA.
- Material Science and Engineering, University of Delaware, Newark, DE, USA
| | - Catherine A Fromen
- Chemical and Biomolecular Engineering, University of Delaware, Newark, DE, USA.
| |
Collapse
|
5
|
George OJ, Song J, Benson JM, Fang Y, Zhang H, Burris DL, Fox JM, Jia X. Tunable Synthesis of Hydrogel Microfibers via Interfacial Tetrazine Ligation. Biomacromolecules 2022; 23:3017-3030. [PMID: 35737940 PMCID: PMC10410669 DOI: 10.1021/acs.biomac.2c00504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Crosslinked, degradable, and cell-adhesive hydrogel microfibers were synthesized via interfacial polymerization employing tetrazine ligation, an exceptionally fast bioorthogonal reaction between strained trans-cyclooctene (TCO) and s-tetrazine (Tz). A hydrophobic trisTCO crosslinker and homo-difunctional poly(ethylene glycol) (PEG)-based macromers with the tetrazine group conjugated to PEG via a stable carbamate (PEG-bisTz1) bond or a labile hydrazone (PEG-bisTz2) linkage were synthesized. After laying an ethyl acetate solution of trisTCO over an aqueous solution of bisTz macromers, mechanically robust microfibers were continuously pulled from the oil-water interface. The resultant microfibers exhibited comparable mechanical and thermal properties but different aqueous stability. Combining PEG-bisTz2 and PEG-bisTz3 with a dangling arginine-glycine-aspartic acid (RGD) peptide in the aqueous phase yielded degradable fibers that supported the attachment and growth of primary vocal fold fibroblasts. The degradable and cell-adhesive hydrogel microfibers are expected to find utility in a wide array of tissue engineering applications.
Collapse
Affiliation(s)
- Olivia J. George
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
| | - Jiyeon Song
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
| | - Jamie M. Benson
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716, USA
| | - Yinzhi Fang
- Department of Chemistry and Biochemistry, University of Delaware, Newark, DE 19716, USA
| | - He Zhang
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
| | - David L. Burris
- Department of Mechanical Engineering, University of Delaware, Newark, DE, 19716, USA
| | - Joseph M. Fox
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
- Department of Chemistry and Biochemistry, University of Delaware, Newark, DE 19716, USA
| | - Xinqiao Jia
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716, USA
| |
Collapse
|
6
|
Kupratis ME, Gure AE, Benson JM, Ortved KF, Burris DL, Price C. Comparative tribology II-Measurable biphasic tissue properties have predictable impacts on cartilage rehydration and lubricity. Acta Biomater 2022; 138:375-389. [PMID: 34728427 DOI: 10.1016/j.actbio.2021.10.049] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 10/22/2021] [Accepted: 10/26/2021] [Indexed: 11/16/2022]
Abstract
Healthy articular cartilage supports load bearing and frictional properties unmatched among biological tissues and man-made bearing materials. Balancing fluid exudation and recovery under loaded and articulated conditions is essential to the tissue's biological and mechanical longevity. Our prior tribological investigations, which leveraged the convergent stationary contact area (cSCA) configuration, revealed that sliding alone can modulate cartilage interstitial fluid pressurization and the recovery and maintenance of lubrication under load through a mechanism termed 'tribological rehydration.' Our recent comparative assessment of tribological rehydration revealed remarkably consistent sliding speed-dependent fluid recovery and lubrication behaviors across femoral condyle cartilage from five mammalian species (equine/horse, bovine/cow, porcine/pig, ovine/sheep, and caprine/goat). In the present study, we identified and characterized key predictive relationships among tissue properties, sliding-induced tribological rehydration, and the modulation/recovery of lubrication within healthy articular cartilage. Using correlational analysis, we linked observed speed-dependent tribological rehydration behaviors to cartilage's geometry and biphasic properties (tensile and compressive moduli, and permeability). Together, these findings demonstrate that easily measurable biphasic tissue characteristics (e.g., bulk tissue material properties, compressive strain magnitude, and strain rates) can be used to predict cartilage's rehydration and lubricating abilities, and ultimately its function in vivo. STATEMENT OF SIGNIFICANCE: In healthy cartilage, articulation recovers fluid lost to static loading thereby sustaining tissue lubricity. Osteoarthritis causes changes to cartilage composition, stiffness, and permeability associated with faster fluid exudation and presumably poorer frictional outcomes. Yet, the relationship between mechanical properties and fluid recovery during articulation/sliding remains unclear. Through innovative, high-speed benchtop sliding and indentation experiments, we found that cartilage's tissue properties regulate its exudation/hydration under slow sliding speeds but have minimal effect at high sliding speeds. In fact, cartilage rehydration appears insensitive to permeability and stiffness under high fluid load support conditions. This new understanding of the balance of cartilage exudation and rehydration during activity, based upon comparative tribology studies, may improve prevention and rehabilitation strategies for joint injuries and osteoarthritis.
Collapse
Affiliation(s)
- Meghan E Kupratis
- Biomedical Engineering, University of Delaware, Newark, Delaware, USA
| | - Ahmed E Gure
- Biomedical Engineering, University of Delaware, Newark, Delaware, USA
| | - Jamie M Benson
- Biomedical Engineering, University of Delaware, Newark, Delaware, USA
| | - Kyla F Ortved
- Clinical Studies, New Bolton Center, University of Pennsylvania School of Veterinary Medicine, Kennett Square, Pennsylvania, USA
| | - David L Burris
- Biomedical Engineering, University of Delaware, Newark, Delaware, USA; Mechanical Engineering, University of Delaware, Newark, Delaware, USA
| | - Christopher Price
- Biomedical Engineering, University of Delaware, Newark, Delaware, USA; Mechanical Engineering, University of Delaware, Newark, Delaware, USA.
| |
Collapse
|
7
|
Kupratis ME, Gure A, Ortved KF, Burris DL, Price C. Comparative Tribology: Articulation-induced rehydration of cartilage across species. Biotribology (Oxf) 2021; 25:100159. [PMID: 37780679 PMCID: PMC10540460 DOI: 10.1016/j.biotri.2020.100159] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
Articular cartilage is a robust tissue that facilitates load distribution and wear-free articulation in diarthrodial joints. These biomechanical capabilities are fundamentally tied to tissue hydration, whereby high interstitial fluid pressures and fluid load support facilitate the maintenance of low tissue strains and frictions. Our recent ex vivo studies of cartilage sliding biomechanics using the convergent stationary contact area (cSCA) configuration, first introduced by Dowson and colleagues, unexpectedly demonstrated that sliding alone can promote recovery of interstitial pressure and lubrication lost to static compression through a mechanism termed 'tribological rehydration.' Although exclusively examined in bovine stifle cartilage to date, we hypothesized that tribological rehydration, i.e., the ability to recover/modulate tissue strains and lubrication through sliding, is a universal behavior of articular cartilage. This study aimed to establish if, and to what extent, sliding-induced tribological rehydration is conserved in articular cartilage across a number of preclinical animal species/models and diarthrodial joints. Using a comparative approach, we found that articular cartilage from equine, bovine, ovine, and caprine stifles, and porcine stifle, hip, and tarsal joints all exhibited remarkably consistent sliding speed-dependent compression/strain recovery and lubrication behaviors under matched contact stresses (0.25 MPa). All cartilage specimens tested supported robust, tribological rehydration during high-speed sliding (>30 mm/s), which as a result of competitive recovery of interstitial lubrication, promoted remarkable decreases in kinetic friction during continuous sliding. The conservation of tribological rehydration across mammalian quadruped articular cartilage suggests that sliding-induced recovery of interstitial hydration represents an important tissue adaptation and largely understudied contributor to the biomechanics of cartilage and joints.
Collapse
Affiliation(s)
| | - Ahmed Gure
- Bioengineering, University of Texas Arlington
| | - Kyla F. Ortved
- Clinical Studies, New Bolton Center, University of Pennsylvania
| | - David L. Burris
- Biomedical Engineering, University of Delaware
- Mechanical Engineering, University of Delaware
| | - Christopher Price
- Biomedical Engineering, University of Delaware
- Mechanical Engineering, University of Delaware
| |
Collapse
|
8
|
Benson JM, Kook C, Moore AC, Voinier S, Price C, Burris DL. Range-of-motion affects cartilage fluid load support: functional implications for prolonged inactivity. Osteoarthritis Cartilage 2021; 29:134-142. [PMID: 33227436 DOI: 10.1016/j.joca.2020.11.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 10/09/2020] [Accepted: 11/11/2020] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Joint movements sustain cartilage fluid load support (FLS) through a combination of contact migration and periodic bath exposure. Although there have been suggestions that small involuntary movements may disrupt load-induced exudation during prolonged inactivity, theoretical studies have shown otherwise. This work used well-controlled explant measurements to experimentally test an existing hypothesis that the range-of-motion must exceed the contact length to sustain non-zero FLS. METHOD Smooth glass spheres (1.2-3.2 mm radius) were slid at 1.5 mm/s (Péclet number >100) against bovine osteochondral explants under varying normal loads (0.05-0.1 N) and migration lengths (0.05-7 mm) using a custom instrument. In situ deformation measurements were used to quantify FLS. RESULTS Non-zero FLS was maintained at migration lengths as small as 0.05 mm or <10% the typical contact diameter. FLS peaked when track lengths exceeded 10 times the contact diameter. For migration lengths below this threshold, FLS decreased with increased contact stress. CONCLUSIONS Migration lengths far smaller than the contact diameter can sustain non-zero FLS, which, from a clinical perspective, indicates that fidgeting and drifting can mitigate exudation and loss of FLS during prolonged sitting and standing. Nonetheless, FLS decreased monotonically with decreased migration length when migration lengths were less than 10 times the contact diameter. The results demonstrate: (1) potential biomechanical benefits from small movement (e.g., drifting and fidgeting); (2) the quantitative limits of those benefits; (3) and how loads, movement patterns, and mobility likely impact long term FLS.
Collapse
Affiliation(s)
- J M Benson
- Department of Biomedical Engineering, USA
| | - C Kook
- Department of Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - A C Moore
- Department of Biomedical Engineering, USA
| | - S Voinier
- Department of Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - C Price
- Department of Biomedical Engineering, USA
| | - D L Burris
- Department of Biomedical Engineering, USA; Department of Mechanical Engineering, University of Delaware, Newark, DE, USA.
| |
Collapse
|
9
|
Abstract
Purpose/Aim: Epidemiological evidence suggests, contrary to popular mythos, that increased exercise/joint activity does not place articular cartilage at increased risk of disease, but instead promotes joint health. One explanation for this might be activity-induced cartilage rehydration; where joint articulation drives restoration of tissue hydration, thickness, and dependent tribomechanical outcomes (e.g., load support, stiffness, and lubricity) lost to joint loading. However, there have been no studies investigating how patterning of intermittent articulation influences the hydration and biomechanical functions of cartilage.Materials and Methods: Here we leveraged the convergent stationary contact area (cSCA) testing configuration and its unique ability to drive tribological rehydration, to elucidate how intermittency of activity affects the biomechanical functions of bovine stifle cartilage under well-controlled sliding conditions that have been designed to model a typical "day" of human joint activity.Results: For a fixed volume of "daily" activity (30 min) and sedentary time (60 min), breaking up intermittent activity into longer and less-frequent bouts (corresponding to longer continuous sedentary periods) resulted in the exposure of articular cartilage to markedly greater strains, losses of interstitial pressure, and friction coefficients.Conclusions: These results demonstrated that the regularity of ex vivo activity regimens, specifically the duration of sedentary bouts, had a dominant effect on the biomechanical functions of articular cartilage. In more practical terms, the results suggest that brief but regular movement patterns (e.g., every hour) may be biomechanically preferred to long and infrequent movement patterns (e.g., a long walk after a sedentary day) when controlling for daily activity volume (e.g., 30 min).
Collapse
Affiliation(s)
- Brian T Graham
- Department of Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - Axel C Moore
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| | - David L Burris
- Department of Mechanical Engineering, University of Delaware, Newark, DE, USA.,Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| | - Christopher Price
- Department of Mechanical Engineering, University of Delaware, Newark, DE, USA.,Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| |
Collapse
|
10
|
Qu J, Garabedian N, Burris DL, Martin DC. Durability of Poly(3,4-ethylenedioxythiophene) (PEDOT) films on metallic substrates for bioelectronics and the dominant role of relative shear strength. J Mech Behav Biomed Mater 2019; 100:103376. [DOI: 10.1016/j.jmbbm.2019.103376] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 07/19/2019] [Accepted: 07/30/2019] [Indexed: 01/07/2023]
|
11
|
Borovsky BP, Garabedian NT, McAndrews GR, Wieser RJ, Burris DL. Integrated QCM-Microtribometry: Friction of Single-Crystal MoS 2 and Gold from μm/s to m/s. ACS Appl Mater Interfaces 2019; 11:40961-40969. [PMID: 31604008 DOI: 10.1021/acsami.9b15764] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Two opposing microtribometry approaches have been developed over the past decade to help connect the dots between fundamental and practical tribology measurements: spring-based (e.g., AFM) approaches use low speed, low stiffness, and long relative slip length to quantify friction, while quartz crystal microbalance (QCM)-based approaches use high speed, high stiffness, and short relative slip length. Because the friction forces generated in these experiments are attributed to entirely different phenomena, it is unclear if or how the resulting friction forces are related. This study aims to resolve this uncertainty by integrating these distinct techniques into a single apparatus that allows two independent measurements of friction at a single interface. Alumina microspheres were tested against single-crystal MoS2, a model nominally wear-free solid lubricant, and gold, a model metal control, at loads between 0.01 and 1 mN. The combined results from both measurement approaches gave friction coefficients (mean ± standard error) of 0.087 ± 0.007 and 0.27 ± 0.02 for alumina-MoS2 and alumina-gold, respectively. The observed agreement between these methods for two different material systems suggests that friction in microscale contacts can be far less sensitive to external effects from compliance and slip speed than currently thought. Perhaps more importantly, this Article describes and validates a novel approach to closing the "tribology gap" while demonstrating how integration creates new opportunities for fundamental studies of practical friction.
Collapse
Affiliation(s)
- B P Borovsky
- Department of Physics , St. Olaf College , Northfield , Minnesota 55057 , United States
| | - N T Garabedian
- Department of Mechanical Engineering , University of Delaware , Newark , Delaware 19716 , United States
| | - G R McAndrews
- Department of Physics , St. Olaf College , Northfield , Minnesota 55057 , United States
| | - R J Wieser
- Department of Physics , St. Olaf College , Northfield , Minnesota 55057 , United States
| | - D L Burris
- Department of Mechanical Engineering , University of Delaware , Newark , Delaware 19716 , United States
| |
Collapse
|
12
|
Farnham MS, Larson RE, Burris DL, Price C. Effects of mechanical injury on the tribological rehydration and lubrication of articular cartilage. J Mech Behav Biomed Mater 2019; 101:103422. [PMID: 31527014 DOI: 10.1016/j.jmbbm.2019.103422] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Revised: 09/05/2019] [Accepted: 09/06/2019] [Indexed: 12/14/2022]
Abstract
Healthy articular cartilage is crucial to joint function, as it provides the low friction and load bearing surface necessary for joint articulation. Nonetheless, joint injury places patients at increased risk of experiencing both accelerated cartilage degeneration and wear, and joint dysfunction due to post-traumatic osteoarthritis (PTOA). In this study, we used our ex vivo convergent stationary contact area (cSCA) explant testing configuration to demonstrate that high-speed sliding of healthy tissues against glass could drive consistent and reproducible recovery of compression-induced cartilage deformation, through the mechanism of 'tribological rehydration'. In contrast, the presence of physical cartilage damage, mimicking those injuries known to precipitate PTOA, could compromise tribological rehydration and the sliding-driven recovery of cartilage function. Full-thickness cartilage injuries (i.e. fissures and chondral defects) markedly suppressed sliding-driven tribological rehydration. In contrast, impaction to cartilage, which caused surface associated damage, had little effect on the immediate tribomechanical response of explants to sliding (deformation/strain, tribological rehydration, and friction/lubricity). By leveraging the unique ability of the cSCA configuration to support tribological rehydration, this study permitted the first direct ex vivo investigation of injury-dependent strain and friction outcomes in cartilage under testing conditions that replicate and maintain physiologically-relevant levels of fluid load support and frictional outcomes under high sliding speeds (80 mm/s) and moderate compressive stresses (~0.3 MPa). Understanding how injury alters cartilage tribomechanics during sliding sheds light on mechanisms by which cartilage's long-term resilience and low frictional properties are maintained, and can guide studies investigating the functional consequences of physical injury and joint articulation on cartilage health, disease, and rehabilitation.
Collapse
Affiliation(s)
- Margot S Farnham
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA.
| | - Riley E Larson
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA.
| | - David L Burris
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA; Department of Mechanical Engineering, University of Delaware, Newark, DE, USA.
| | - Christopher Price
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA; Department of Mechanical Engineering, University of Delaware, Newark, DE, USA.
| |
Collapse
|
13
|
Dicker KT, Moore AC, Garabedian NT, Zhang H, Scinto SL, Akins RE, Burris DL, Fox JM, Jia X. Spatial Patterning of Molecular Cues and Vascular Cells in Fully Integrated Hydrogel Channels via Interfacial Bioorthogonal Cross-Linking. ACS Appl Mater Interfaces 2019; 11:16402-16411. [PMID: 30998317 PMCID: PMC6506358 DOI: 10.1021/acsami.9b04383] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Fully integrated hydrogel channels were fabricated via interfacial bioorthogonal cross-linking, a diffusion-controlled method for the creation and patterning of synthetic matrices based on the rapid bioorthogonal reaction between s-tetrazines (Tz) and trans-cyclooctene (TCO) dienophiles. Injecting an aqueous solution of a bisTCO cross-linker into a reservoir of tetrazine-modified hyaluronic acid (HA-Tz), while simultaneously drawing the syringe needle through the reservoir, yielded a cross-linked hydrogel channel that was mechanically robust. Fluorescent tags and biochemical signals were spatially patterned into the channel wall through time-dependent perfusion of TCO-conjugated molecules into the lumen of the channel. Different cell populations were spatially encapsulated in the channel wall via temporal alteration of cells in the HA-Tz reservoir. The interfacial approach enabled the spatial patterning of vascular cells, including human abdominal aorta endothelial cells, aortic vascular smooth muscle cells, and aortic adventitial fibroblasts, into the hydrogel channels with high viability and proper morphology in the anatomical order found in human arteries. The bioorthogonal platform does not rely on external triggers and represents the first step toward the engineering of functional and implantable arteries.
Collapse
Affiliation(s)
- Kevin T. Dicker
- Department of Materials Science and Engineering, University of Delaware, Newark, DE, 19716, USA
| | - Axel C. Moore
- Department of Biomedical Engineering, University of Delaware, Newark, DE, 19716, USA
| | | | - Han Zhang
- Department of Chemistry and Biochemistry, University of Delaware, Newark, DE, 19716, USA
| | - Samuel L. Scinto
- Department of Chemistry and Biochemistry, University of Delaware, Newark, DE, 19716, USA
| | - Robert E. Akins
- Department of Biomedical Research, A.I. DuPont Hospital for Children, Nemours Children’s Clinic, Wilmington, DE 19803, USA
| | - David L. Burris
- Department of Mechanical Engineering, University of Delaware, Newark, DE 19716, USA
| | - Joseph M. Fox
- Department of Materials Science and Engineering, University of Delaware, Newark, DE, 19716, USA
- Department of Chemistry and Biochemistry, University of Delaware, Newark, DE, 19716, USA
- Corresponding authors: ,
| | - Xinqiao Jia
- Department of Materials Science and Engineering, University of Delaware, Newark, DE, 19716, USA
- Department of Biomedical Engineering, University of Delaware, Newark, DE, 19716, USA
- Corresponding authors: ,
| |
Collapse
|
14
|
Graham BT, Wright AD, Burris DL, Axe MJ, Raisis LW, Price C. Quantification of solute diffusivity in osteoarthritic human femoral cartilage using correlation spectroscopy. J Orthop Res 2018; 36:3256-3267. [PMID: 30183098 DOI: 10.1002/jor.24138] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2018] [Accepted: 08/25/2018] [Indexed: 02/04/2023]
Abstract
Osteoarthritis is a chronic joint disease characterized by articular cartilage degeneration, pain, and disability. As an avascular tissue, the movement of water and solutes through the tissue is critical to cartilage health and function, and early changes in solute diffusivity due to micro-scale changes in the properties of cartilage's extracellular matrix might precede clinical symptoms. A diagnostic technique for quantifying alteration to the diffusive environment of cartilage that precedes macroscopic changes may allow for the earlier identification of osteoarthritic disease, facilitating earlier intervention strategies. Toward this end, we used two confocal microscopy-based correlation spectroscopy techniques, fluorescence correlation spectroscopy and raster image correlation spectroscopy, to quantify the diffusion of two small solutes, fluorescein and 3k dextran, within human osteoarthritic articular cartilage. Our goal was to determine if these relatively simple optical correlation spectroscopy techniques could detect changes in solute diffusivity associated with increasing cartilage damage as assessed by International Cartilage Repair Society scoring guidelines, and if these measures are correlated with mechanical and compositional measures of cartilage health. Our data show a modest, yet significant increase in solute diffusivity and cartilage permeability with increasing osteoarthritis score (grades 0-2), with a strong correlation between diffusion coefficients, permeability, and cartilage composition. The described correlation spectroscopy techniques are quick, simple, and easily adapted to existing laboratory workflow and equipment. Furthermore, the minimal solute concentrations and laser powers required for analysis, combined with recent advances in arthroscopic microscopy, suggest correlation spectroscopy techniques as translational candidates for development into early OA diagnosis tools. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:3256-3267, 2018.
Collapse
Affiliation(s)
- Brian T Graham
- Department of Mechanical Engineering, University of Delaware, Newark, Delaware
| | - Alison D Wright
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware
| | - David L Burris
- Department of Mechanical Engineering, University of Delaware, Newark, Delaware.,Department of Biomedical Engineering, University of Delaware, Newark, Delaware
| | - Michael J Axe
- Department of Physical Therapy, University of Delaware, Newark, Delaware.,First State Orthopaedics, Christiana Care Health System, Newark, Delaware
| | - Leo W Raisis
- Department of Physical Therapy, University of Delaware, Newark, Delaware.,First State Orthopaedics, Christiana Care Health System, Newark, Delaware
| | - Christopher Price
- Department of Mechanical Engineering, University of Delaware, Newark, Delaware.,Department of Biomedical Engineering, University of Delaware, Newark, Delaware
| |
Collapse
|
15
|
Liu S, Moore AC, Zerdoum AB, Zhang H, Scinto SL, Zhang H, Gong L, Burris DL, Rajasekaran AK, Fox JM, Jia X. Cellular interactions with hydrogel microfibers synthesized via interfacial tetrazine ligation. Biomaterials 2018; 180:24-35. [PMID: 30014964 PMCID: PMC6091885 DOI: 10.1016/j.biomaterials.2018.06.042] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2018] [Revised: 06/05/2018] [Accepted: 06/30/2018] [Indexed: 12/12/2022]
Abstract
Fibrous proteins found in the natural extracellular matrix (ECM) function as host substrates for migration and growth of endogenous cells during wound healing and tissue repair processes. Although various fibrous scaffolds have been developed to recapitulate the microstructures of the native ECM, facile synthesis of hydrogel microfibers that are mechanically robust and biologically active have been elusive. Described herein is the use of interfacial bioorthogonal polymerization to create hydrogel-based microfibrous scaffolds via tetrazine ligation. Combination of a trifunctional strained trans-cyclooctene monomer and a difunctional s-tetrazine monomer at the oil-water interface led to the formation of microfibers that were stable under cell culture conditions. The bioorthogonal nature of the synthesis allows for direct incorporation of tetrazine-conjugated peptides or proteins with site-selectively, genetically encoded tetrazines. The microfibers provide physical guidance and biochemical signals to promote the attachment, division and migration of fibroblasts. Mechanistic investigations revealed that fiber-guided cell migration was both F-actin and microtubule-dependent, confirming contact guidance by the microfibers. Prolonged culture of fibroblasts in the presence of an isolated microfiber resulted in the formation of a multilayered cell sheet wrapping around the fiber core. A fibrous mesh provided a 3D template to promote cell infiltration and tissue-like growth. Overall, the bioorthogonal approach led to the straightforward synthesis of crosslinked hydrogel microfibers that can potentially be used as instructive materials for tissue repair and regeneration.
Collapse
Affiliation(s)
- Shuang Liu
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
| | - Axel C Moore
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716, USA
| | - Aidan B Zerdoum
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716, USA
| | - Han Zhang
- Department of Chemistry and Biochemistry, University of Delaware, Newark, DE 19716, USA
| | - Samuel L Scinto
- Department of Chemistry and Biochemistry, University of Delaware, Newark, DE 19716, USA
| | - He Zhang
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
| | - Liang Gong
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
| | - David L Burris
- Department of Mechanical Engineering, University of Delaware, Newark, DE 19716, USA
| | | | - Joseph M Fox
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA; Department of Chemistry and Biochemistry, University of Delaware, Newark, DE 19716, USA.
| | - Xinqiao Jia
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA; Department of Biomedical Engineering, University of Delaware, Newark, DE 19716, USA.
| |
Collapse
|
16
|
Dicker KT, Song J, Moore AC, Zhang H, Li Y, Burris DL, Jia X, Fox JM. Core-shell patterning of synthetic hydrogels via interfacial bioorthogonal chemistry for spatial control of stem cell behavior. Chem Sci 2018; 9:5394-5404. [PMID: 30009011 PMCID: PMC6009435 DOI: 10.1039/c8sc00495a] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Accepted: 05/24/2018] [Indexed: 12/29/2022] Open
Abstract
A new technique is described for the patterning of cell-guidance cues in synthetic extracellular matrices (ECM) for tissue engineering applications. Using s-tetrazine modified hyaluronic acid (HA), bis-trans-cyclooctene (TCO) crosslinkers and monofunctional TCO conjugates, interfacial bioorthogonal crosslinking was used to covalently functionalize hydrogels as they were synthesized at the liquid-gel interface. Through temporally controlled introduction of TCO conjugates during the crosslinking process, the enzymatic degradability, cell adhesivity, and mechanical properties of the synthetic microenvironment can be tuned with spatial precision. Using human mesenchymal stem cells (hMSCs) and hydrogels with a core-shell structure, we demonstrated the ability of the synthetic ECM with spatially defined guidance cues to modulate cell morphology in a biomimetic fashion. This new method for the spatially resolved introduction of cell-guidance cues for the establishment of functional tissue constructs complements existing methods that require UV-light or specialized equipment.
Collapse
Affiliation(s)
- K T Dicker
- Department of Materials Science and Engineering , University of Delaware , DuPont Hall , Newark , DE 19716 , USA . ;
| | - J Song
- Department of Materials Science and Engineering , University of Delaware , DuPont Hall , Newark , DE 19716 , USA . ;
| | - A C Moore
- Department of Biomedical Engineering , University of Delaware , Colburn Lab , Newark , DE 19716 , USA
| | - H Zhang
- Department of Chemistry and Biochemistry , University of Delaware , Brown Lab , Newark , DE 19716 , USA
| | - Y Li
- Department of Chemistry and Biochemistry , University of Delaware , Brown Lab , Newark , DE 19716 , USA
| | - D L Burris
- Department of Biomedical Engineering , University of Delaware , Colburn Lab , Newark , DE 19716 , USA
- Department of Mechanical Engineering , University of Delaware , Spencer Lab , Newark , DE 19716 , USA
| | - X Jia
- Department of Materials Science and Engineering , University of Delaware , DuPont Hall , Newark , DE 19716 , USA . ;
- Department of Biomedical Engineering , University of Delaware , Colburn Lab , Newark , DE 19716 , USA
| | - J M Fox
- Department of Materials Science and Engineering , University of Delaware , DuPont Hall , Newark , DE 19716 , USA . ;
- Department of Chemistry and Biochemistry , University of Delaware , Brown Lab , Newark , DE 19716 , USA
| |
Collapse
|
17
|
Graham BT, Moore AC, Burris DL, Price C. Mapping the spatiotemporal evolution of solute transport in articular cartilage explants reveals how cartilage recovers fluid within the contact area during sliding. J Biomech 2018; 71:271-276. [PMID: 29454544 DOI: 10.1016/j.jbiomech.2018.01.041] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2017] [Revised: 01/12/2018] [Accepted: 01/28/2018] [Indexed: 01/25/2023]
Abstract
The interstitial fluid within articular cartilage shields the matrix from mechanical stresses, reduces friction and wear, enables biochemical processes, and transports solutes into and out of the avascular extracellular matrix. The balanced competition between fluid exudation and recovery under load is thus critical to the mechanical and biological functions of the tissue. We recently discovered that sliding alone can induce rapid solute transport into buried cartilage contact areas via a phenomenon termed tribological rehydration. In this study, we use in situ confocal microscopy measurements to track the spatiotemporal propagation of a small neutral solute into the buried contact area to clarify the fluid mechanics underlying the tribological rehydration phenomenon. Sliding experiments were interrupted by periodic static loading to enable scanning of the entire contact area. Spatiotemporal patterns of solute transport combined with tribological data suggested pressure driven flow through the extracellular matrix from the contact periphery rather than into the surface via a fluid film. Interestingly, these testing interruptions also revealed dynamic, repeatable and history-independent fluid loss and recovery processes consistent with those observed in vivo. Unlike the migrating contact area, which preserves hydration by moving faster than interstitial fluid can flow, our results demonstrate that the stationary contact area can maintain and actively recover hydration through a dynamic competition between load-induced exudation and sliding-induced recovery. The results demonstrate that sliding contributes to the recovery of fluid and solutes by cartilage within the contact area while clarifying the means by which it occurs.
Collapse
Affiliation(s)
- Brian T Graham
- Department of Mechanical Engineering, University of Delaware, Newark, DE, United States.
| | - Axel C Moore
- Department of Biomedical Engineering, University of Delaware, Newark, DE, United States.
| | - David L Burris
- Department of Mechanical Engineering, University of Delaware, Newark, DE, United States; Department of Biomedical Engineering, University of Delaware, Newark, DE, United States.
| | - Christopher Price
- Department of Mechanical Engineering, University of Delaware, Newark, DE, United States; Department of Biomedical Engineering, University of Delaware, Newark, DE, United States.
| |
Collapse
|
18
|
Emerson JA, Garabedian NT, Moore AC, Burris DL, Furst EM, Epps TH. Unexpected Tribological Synergy in Polymer Blend Coatings: Leveraging Phase Separation to Isolate Domain Size Effects and Reduce Friction. ACS Appl Mater Interfaces 2017; 9:34480-34488. [PMID: 28945331 DOI: 10.1021/acsami.7b10170] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
We employed a systematic processing approach to control phase separation in polymer blend thin films and significantly reduce dynamic friction coefficients (μ)s. We leveraged this modulation of phase separation to generate composite surfaces with dynamic friction coefficients that were substantially lower than expected on the basis of simple mixing rules, and in several cases, these friction coefficients were lower than those of both pure components. Using a model polyisoprene [PI]/polystyrene [PS] composite system, a minimum μ was found in films with PS mass fractions between 0.60 and 0.80 (μblend = 0.11 ± 0.03); that value was significantly lower than the friction coefficient of PS (μPS = 0.52 ± 0.01) or PI (μPI = 1.3 ± 0.09) homopolymers and was comparable to the friction coefficient of poly(tetrafluoroethylene) [PTFE] (μPTFE = 0.09 ± 0.01) measured under similar conditions. Additionally, through experiments in which the domain size was systematically varied at constant composition (through an annealing process), we demonstrated that μ decreased with decreasing characteristic domain size. Thus, the tribological synergy between PS and PI domains (discrete size, physical domain isolation, and overall film composition) was shown to play an integral role in the friction and wear of these PS/PI composites. Overall, our results suggest that even high friction polymers can be used to create low friction polymer blends by following appropriate design rules and demonstrate that engineering microstructure is critical for controlling the friction and adhesion properties of composite films for tribologically relevant coatings.
Collapse
Affiliation(s)
- Jillian A Emerson
- Department of Chemical & Biomolecular Engineering, University of Delaware , Newark, Delaware 19716, United States
| | - Nikolay T Garabedian
- Department of Mechanical Engineering, University of Delaware , Newark, Delaware 19716, United States
| | - Axel C Moore
- Department of Biomedical Engineering, University of Delaware , Newark, Delaware 19716, United States
| | - David L Burris
- Department of Mechanical Engineering, University of Delaware , Newark, Delaware 19716, United States
| | - Eric M Furst
- Department of Chemical & Biomolecular Engineering, University of Delaware , Newark, Delaware 19716, United States
| | - Thomas H Epps
- Department of Chemical & Biomolecular Engineering, University of Delaware , Newark, Delaware 19716, United States
- Department of Materials Science & Engineering, University of Delaware , Newark, Delaware 19716, United States
| |
Collapse
|
19
|
Moore AC, Burris DL. Tribological rehydration of cartilage and its potential role in preserving joint health. Osteoarthritis Cartilage 2017; 25:99-107. [PMID: 27693500 DOI: 10.1016/j.joca.2016.09.018] [Citation(s) in RCA: 73] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2016] [Revised: 09/15/2016] [Accepted: 09/22/2016] [Indexed: 02/02/2023]
Abstract
OBJECTIVE During exercise, cartilage recovers interstitial fluid lost during inactivity, which explains how tissue thickness and joint space are maintained over time. This recovery phenomenon is currently explained by a combination of osmotic swelling during intermittent bath exposure and sub-ambient pressurization during unloading. This paper tests an alternate hypothesis that cartilage can retain and recover interstitial fluid in the absence of bath exposure and unloading when physiological hydrodynamics are present. METHOD Stationary cartilage-on-flat experiments were conducted to eliminate intermittent bath exposure as a potential contributor to fluid uptake. In situ compression measurements were used to monitor the loss, retention, and recovery of interstitial fluid during testing in saline. Samples were left larger than the contact area to preserve a convergence zone for hydrodynamic pressurization. RESULTS Interstitial fluid lost during static loading was recovered during sliding in the absence of unloading and contact migration; fluid recovery in a stationary contact cannot be explained by biphasic theory and suggests a fundamentally new contributor to the recovery process. We call the phenomenon 'tribological rehydration' because recovery was induced by sliding rather than by unloading or migration. Sensitivities to sliding speed, surface permeability, and nature of the convergence wedge are consistent with the hypothesis that hydrodynamic effects underlie the tribological rehydration phenomenon. CONCLUSIONS This study demonstrates that cartilage can retain and recover interstitial fluid without migration or unloading. The results suggest that hydrodynamic effects in the joint are not only important contributors to lubrication, they are likely equally important to the preservation of joint space.
Collapse
Affiliation(s)
- A C Moore
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| | - D L Burris
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA; Department of Mechanical Engineering, University of Delaware, Newark, DE, USA.
| |
Collapse
|
20
|
Moore AC, DeLucca JF, Elliott DM, Burris DL. Quantifying Cartilage Contact Modulus, Tension Modulus, and Permeability With Hertzian Biphasic Creep. J Tribol 2016; 138:0414051-414057. [PMID: 27536012 PMCID: PMC4967882 DOI: 10.1115/1.4032917] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2015] [Revised: 02/11/2016] [Indexed: 05/05/2023]
Abstract
This paper describes a new method, based on a recent analytical model (Hertzian biphasic theory (HBT)), to simultaneously quantify cartilage contact modulus, tension modulus, and permeability. Standard Hertzian creep measurements were performed on 13 osteochondral samples from three mature bovine stifles. Each creep dataset was fit for material properties using HBT. A subset of the dataset (N = 4) was also fit using Oyen's method and FEBio, an open-source finite element package designed for soft tissue mechanics. The HBT method demonstrated statistically significant sensitivity to differences between cartilage from the tibial plateau and cartilage from the femoral condyle. Based on the four samples used for comparison, no statistically significant differences were detected between properties from the HBT and FEBio methods. While the finite element method is considered the gold standard for analyzing this type of contact, the expertise and time required to setup and solve can be prohibitive, especially for large datasets. The HBT method agreed quantitatively with FEBio but also offers ease of use by nonexperts, rapid solutions, and exceptional fit quality (R2 = 0.999 ± 0.001, N = 13).
Collapse
Affiliation(s)
- A C Moore
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716
| | - J F DeLucca
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716
| | - D M Elliott
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716
| | | |
Collapse
|
21
|
Ruggiero L, Zimmerman BK, Park M, Han L, Wang L, Burris DL, Lu XL. Roles of the Fibrous Superficial Zone in the Mechanical Behavior of TMJ Condylar Cartilage. Ann Biomed Eng 2015; 43:2652-62. [DOI: 10.1007/s10439-015-1320-9] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2015] [Accepted: 04/07/2015] [Indexed: 11/28/2022]
|
22
|
Abstract
In temporomandibular joints (TMJs), the disc and condylar cartilage function as load-bearing, shock-absorbing, and friction-reducing materials. The ultrastructure of the TMJ disc and cartilage is different from that of hyaline cartilage in other diarthrodial joints, and little is known about their lubrication mechanisms. In this study, we performed micro-tribometry testing on the TMJ disc and condylar cartilage to obtain their region- and direction-dependent friction properties. Frictional tests with a migrating contact area were performed on 8 adult porcine TMJs at 5 different regions (anterior, posterior, central, medial, and lateral) in 2 orthogonal directions (anterior-posterior and medial-lateral). Some significant regional differences were detected, and the lateral-medial direction showed higher friction than the anterior-posterior direction on both tissues. The mean friction coefficient of condylar cartilage against steel was 0.027, but the disc, at 0.074, displayed a significantly higher friction coefficient. The 2 tissues also exhibited different frictional dependencies on sliding speed and normal loading force. Whereas the friction of condylar cartilage decreased with increased sliding speed and was independent of the magnitude of normal force, friction of the disc showed no dependence on sliding speed but decreased as normal force increased. Further analysis of the Péclet number and frictional coefficients suggested that condylar cartilage relies on interstitial fluid pressurization to a greater extent than the corresponding contact area of the TMJ disc.
Collapse
Affiliation(s)
- B K Zimmerman
- Department of Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - E D Bonnevie
- Department of Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - M Park
- Department of Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - Y Zhou
- Department of Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - L Wang
- Department of Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - D L Burris
- Department of Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - X L Lu
- Department of Mechanical Engineering, University of Delaware, Newark, DE, USA
| |
Collapse
|
23
|
Khare HS, Burris DL. The extended wedge method: atomic force microscope friction calibration for improved tolerance to instrument misalignments, tip offset, and blunt probes. Rev Sci Instrum 2013; 84:055108. [PMID: 23742590 DOI: 10.1063/1.4804163] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
One of the major challenges in understanding and controlling friction is the difficulty in bridging the length and time scales of macroscale contacts and those of the single asperity interactions they comprise. While the atomic force microscope (AFM) offers a unique ability to probe tribological surfaces in a wear-free single-asperity contact, instrument calibration challenges have limited the usefulness of this technique for quantitative nanotribological studies. A number of lateral force calibration techniques have been proposed and used, but none has gained universal acceptance due to practical considerations, configuration limitations, or sensitivities to unknowable error sources. This paper describes a simple extension of the classic wedge method of AFM lateral force calibration which: (1) allows simultaneous calibration and measurement on any substrate, thus eliminating prior tip damage and confounding effects of instrument setup adjustments; (2) is insensitive to adhesion, PSD cross-talk, transducer/piezo-tube axis misalignment, and shear-center offset; (3) is applicable to integrated tips and colloidal probes; and (4) is generally applicable to any reciprocating friction coefficient measurement. The method was applied to AFM measurements of polished carbon (99.999% graphite) and single crystal MoS2 to demonstrate the technique. Carbon and single crystal MoS2 had friction coefficients of μ = 0.20 ± 0.04 and μ = 0.006 ± 0.001, respectively, against an integrated Si probe. Against a glass colloidal sphere, MoS2 had a friction coefficient of μ = 0.005 ± 0.001. Generally, the measurement uncertainties ranged from 10%-20% and were driven by the effect of actual frictional variation on the calibration rather than calibration error itself (i.e., due to misalignment, tip-offset, or probe radius).
Collapse
Affiliation(s)
- H S Khare
- 126 Spencer Laboratory, Department of Mechanical Engineering, University of Delaware, Newark, Delaware 19716, USA
| | | |
Collapse
|
24
|
Abstract
Cells sense and respond to their environment. Mechanotransduction is the process by which mechanical forces, stress, and strains are converted into biochemical signals that control cell behavior. In recent decades it has been shown that appropriate mechanical signals are essential to tissue health, but the role of friction and direct contact shearing across cell surfaces has been essentially unexplored. This, despite the obvious existence of numerous biological tissues whose express function depends on sliding contacts. In our studies on frictional interactions of corneal cells we find that the friction coefficients are on the order of mu = 0.03-0.06 for in vitro and in vivo experiments. Additionally, we observe cell death after single cycles of sliding at contact pressures estimated to be approximately 12 kPa. These experimental results suggest that frictional contact forces produce mechanical stresses and strains that are in the cellular mechanosensing ranges.
Collapse
Affiliation(s)
- T E Angelini
- Dept. of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL 32611, USA
| | | | | | | | | | | |
Collapse
|
25
|
Baro VJ, Bonnevie ED, Lai X, Price C, Burris DL, Wang L. Functional characterization of normal and degraded bovine meniscus: rate-dependent indentation and friction studies. Bone 2012; 51:232-40. [PMID: 22449445 PMCID: PMC3593088 DOI: 10.1016/j.bone.2012.03.009] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2011] [Revised: 02/25/2012] [Accepted: 03/06/2012] [Indexed: 11/24/2022]
Abstract
The menisci are known to play important roles in normal joint function and the development of diseases such as osteoarthritis. However, our understanding of meniscus' load bearing and lubrication properties at the tissue level remains limited. The objective of this investigation was to characterize the site- and rate-dependency of the compressive and frictional responses of the meniscus under a spherical contact load. Using a custom testing device, indentation tests with rates of 1, 10, 25, 50, and 100μm/s were performed on bovine medial meniscus explants, which were harvested from five locations including the femoral apposing surface at the anterior, central, and posterior locations and the central portion at the deep layer and at the tibial apposing surface (n=5 per location). Sliding tests with rates of 0.05, 0.25, 1, and 5mm/s were performed on the central femoral aspect and central tibial aspect superficial samples (n=6 per location). A separate set of superficial samples were subjected to papain digestion and tested prior to and post treatment. Our findings are: i) the Hertz contact model can be used to fit the force responses of meniscus under the conditions tested; ii) the anterior region is significantly stiffer than the posterior region and tissue modulus does not vary with tissue depth at the central region; iii) the friction coefficient of the meniscus is on the order of 0.02 under migratory contacts and the femoral apposing surface tends to show lower friction than the tibial apposing surface; iv) the meniscus exhibits increased modulus and lubrication with increased indentation and sliding rates; v) matrix degradation impedes the functional load support and lubrication properties of the tissue. The site- and rate-dependent properties of the meniscus may be attributed to spatial variations of the tissue's biphasic structure. These properties substantiate the role of the meniscus as one of the important bearing surfaces of the knee. These data contribute to an improved understanding of meniscus function, and its role in degenerative joint diseases. In addition, the results provide functional metrics for developing engineered tissue replacements. This article is part of a Special Issue entitled Osteoarthritis.
Collapse
Affiliation(s)
- Vincent J. Baro
- Center for Biomedical Engineering Research, Department of Mechanical Engineering, University of Delaware, Newark, DE 19716, USA
| | - Edward D. Bonnevie
- Center for Biomedical Engineering Research, Department of Mechanical Engineering, University of Delaware, Newark, DE 19716, USA
| | - Xiaohan Lai
- Center for Biomedical Engineering Research, Department of Mechanical Engineering, University of Delaware, Newark, DE 19716, USA
| | - Christopher Price
- Center for Biomedical Engineering Research, Department of Mechanical Engineering, University of Delaware, Newark, DE 19716, USA
| | - David L. Burris
- Center for Biomedical Engineering Research, Department of Mechanical Engineering, University of Delaware, Newark, DE 19716, USA
| | - Liyun Wang
- Center for Biomedical Engineering Research, Department of Mechanical Engineering, University of Delaware, Newark, DE 19716, USA
| |
Collapse
|
26
|
Bonnevie ED, Baro VJ, Wang L, Burris DL. Fluid load support during localized indentation of cartilage with a spherical probe. J Biomech 2012; 45:1036-41. [PMID: 22284430 DOI: 10.1016/j.jbiomech.2011.12.019] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2011] [Revised: 12/19/2011] [Accepted: 12/31/2011] [Indexed: 11/16/2022]
Abstract
Interstitial fluid pressurization, a consequence of a biphasic tissue structure, is essential to the load bearing and lubrication properties of articular cartilage. Focal tissue degradation may interfere with this protective mechanism, eventually leading to gross degeneration and osteoarthritis. Our long-term goal is to determine whether local contacts can be used as a means to probe local tissue integrity and functionality. In the present work, Hertzian rate-controlled microindentation was used as a model of the more complicated sliding system to directly determine the effects of contact radius and deformation rate on interstitial load support. During localized contact between a steel spherical probe and bovine articular cartilage, the equilibrium and non-equilibrium responses were well-fit by the Hertz model (R(2)>0.998) with a mean equilibrium contact modulus of 0.93 MPa. The effective contact modulus and fluid load fraction were independent of indentation depth, contact radius, and normal force; both increased monotonically with indentation rate. At 21 μm/s indentation rate, the cartilage was effectively stiffened by 6-fold with the fluid pressure supporting 85% of the contact force. The results motivated a simple analytical model that directly links the tribomechanical response (including fluid load support) and the Peclet number to measurable material properties and controllable experimental variables. This paper demonstrates that tribological contacts can be used to probe local functional properties. Such measurements can add important insights into the roles of focal tissue damage and impaired local functionality in the pathogenesis of osteoarthritis.
Collapse
Affiliation(s)
- E D Bonnevie
- Department of Mechanical Engineering, University of Delaware Newark, DE 19716, United States
| | | | | | | |
Collapse
|