Jina A, Tierney MJ, Tamada JA, McGill S, Desai S, Chua B, Chang A, Christiansen M. Design, development, and evaluation of a novel microneedle array-based continuous glucose monitor. J Diabetes Sci Technol 2014; 8:483-7. [PMID: 24876610 PMCID: PMC4455438 DOI: 10.1177/1932296814526191] [Citation(s) in RCA: 103] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The development of accurate, minimally invasive continuous glucose monitoring (CGM) devices has been the subject of much work by several groups, as it is believed that a less invasive and more user-friendly device will result in greater adoption of CGM by persons with insulin-dependent diabetes. This article presents the results of preliminary clinical studies in subjects with diabetes of a novel prototype microneedle-based continuous glucose monitor. In this device, an array of tiny hollow microneedles is applied into the epidermis from where glucose in interstitial fluid (ISF) is transported via passive diffusion to an amperometric glucose sensor external to the body. Comparison of 1396 paired device glucose measurements and fingerstick blood glucose readings for up to 72-hour wear in 10 diabetic subjects shows the device to be accurate and well tolerated by the subjects. Overall mean absolute relative difference (MARD) is 15% with 98.4% of paired points in the A+B region of the Clarke error grid. The prototype device has demonstrated clinically accurate glucose readings over 72 hours, the first time a microneedle-based device has achieved such performance.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Anna Chang
- John Muir Physician Network Clinical Research Center, Concord, CA USA
| | | |
Collapse
|
2
|
Abstract
Glucose transport through human skin can be facilitated by electroosmotic flow that results from the application of an electric current across the skin (iontophoresis). A series of studies on human volunteers examined how formulation factors (buffer type, pH, ionic strength, and buffer concentration) affect the amount of glucose extracted from interstitial fluid through the skin. Sampling cells were placed on subjects' forearms and a current of 0.25 mA/cm(2) was passed across the skin for 5 h. Samples were collected every 20 min and analyzed for glucose concentration. Two methods were used. In one method, subjects ingested glucose and one formulation was tested in each pair of sampling cells for the study duration. The ratio of transdermal glucose flux to blood glucose was determined and compared across formulations. In another method, subjects fasted through the study, and different formulations were sequentially tested in each sampling cell. Citrate was found to give higher flux than bicarbonate or phosphate buffers. Transport increased with increasing pH from 4.5 to 6.5 for citrate buffer and 6.5 to 7.5 for bicarbonate buffer. Increased salt concentration in the formulation decreased transport. Increased phosphate concentration increased transport. These results can be used to optimize electroosmotic transport through the skin.
Collapse
Affiliation(s)
- Janet A Tamada
- Alexza Molecular Delivery Corporation, 1001 East Meadow Circle, Palo Alto, CA 94303, USA.
| | | |
Collapse
|
3
|
Abstract
OBJECTIVE The purpose of this study was to characterize the distribution of the rate of change of blood glucose for a diabetic population. RESEARCH DESIGN AND METHODS The study population consisted of 124 adults with type 1 or type 2 diabetes requiring insulin. Study participants applied a GlucoWatch Biographer during the day at home for 5 consecutive days and took finger-prick blood glucose measurements hourly. Subjects kept a diary of meals. The Biographer frequently and automatically measured glucose up to three times per hour for up 12 h. Rates of glucose change were calculated for both Biographer and blood glucose measurements. Rates of glucose change during a separate study of 134 subjects were determined for daytime and nighttime use. RESULTS -Mean (+/-SD) rates of change of glucose of -0.36 +/- 0.95 and 0.36 +/- 0.99 mg. dl(-1). min(-1) were found before and after lunch using blood glucose data and -0.31 +/- 1.23 and 0.43 +/- 1.26 using Biographer data. For both types of diabetes, rates of glucose change exceeded 2 mg. dl(-1). min(-1) before and after meals approximately 10% of the time. Periprandial glucose patterns showed some significant differences between type 1 and type 2 diabetic subjects. Glucose levels changed more gradually at night than during the day. CONCLUSIONS Glucose values were almost equally unstable before and after meals. Glycemic instability around dinner was different in type 1 and type 2 diabetes. The GlucoWatch Biographer was found to be effective in tracking trends in glucose levels and yielded similar results as obtained by finger-prick blood samples.
Collapse
|
4
|
Tamada JA, Davis TL, Leptien AD, Lee J, Wang B, Lopatin M, Wei C, Wilson D, Comyns K, Eastman RC. The effect of preapplication of corticosteroids on skin irritation and performance of the GlucoWatch G2 Biographer. Diabetes Technol Ther 2004; 6:357-67. [PMID: 15198839 DOI: 10.1089/152091504774198052] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Skin irritation due to iontophoresis may limit the frequency of use of devices for drug delivery or transdermal extraction of analytes of clinical interest. This study examined whether preapplication of corticosteroid preparations could reduce skin irritation from iontophoresis used by the GlucoWatch G2 Biographer (Cygnus, Inc., Redwood City, CA) in monitoring interstitial glucose levels frequently and automatically. Numerous corticosteroid preparations were screened to identify formulations that did not interfere with adhesion of the Biographer to the skin or glucose sensing. Kenalog (Westwood-Squibb Pharmaceuticals, Inc., Buffalo, NY) (triamcinolone acetonide) and Cortizone-10 Quick Shot (Pfizer, Inc., New York, NY) (hydrocortisone) sprays were selected and, in a double-masked, randomized, controlled trial, were applied to the forearms of 66 subjects with diabetes and allowed to dry. Biographers were applied and worn for 15 h, and home blood glucose measurements were taken every 30 min to assess accuracy. Irritation was assessed periodically by trained observers and study subjects. Skin irritation was reduced by both corticosteroid sprays, with the fraction of subjects who experienced moderate irritation reduced by 57% and 43% for the Kenalog and Cortizone-10 Quick Shot sprays, respectively. The treatment effect persisted at the 1-week assessment. Preapplication of these preparations did not affect the clinical utility of interstitial glucose readings. Preapplication of Kenalog or Cortizone-10 Quick Shot sprays significantly reduced skin irritation due to iontophoresis, and did not interfere with glucose measurements. This approach may enable the minority of users who experience moderate to severe skin irritation to use the Biographer more frequently for diabetes management.
Collapse
|
5
|
Abstract
OBJECTIVE This study investigated whether glucose readings from a sensor sampling in interstitial fluid differ substantially from blood glucose (BG) values measured at the same time. RESEARCH DESIGN AND METHODS We have evaluated the relationship between BG and glucose extracted from interstitial fluid using the GlucoWatch (Cygnus, Redwood City, CA) biographer, a device that collects glucose from subcutaneous interstitial space through intact skin by application of a low electric current. We evaluated the relative change in the interstitial glucose (IG) signal (IGS) as measured by the biographer versus BG using a normalized two-point sensitivity index (NSI). RESULTS The results show that biographer measures of IG differ in time and magnitude from the corresponding BG values. In particular, the biographer values were shifted in time due to instrumental and physiological lag. Results show an average total lag of 17.2 +/- 7.2 min for all subjects evaluated. The instrumental lag was 13.5 min, suggesting that physiological lag is approximately 5 min. In addition, when glucose was increasing, the change in IGS was less than that in BG, while when BG was decreasing, the change in IGS was greater than that in BG. CONCLUSIONS Similar results have been reported for other measures of IG, suggesting that differences reflect physiological variation in glucose uptake, utilization, and elimination in blood and interstitial space. This further evidence of the difference between IG and BG should be considered when interpreting glucose measurements from devices that sample interstitial fluid.
Collapse
|
6
|
Eastman RC, Chase HP, Buckingham B, Hathout EH, Fuller-Byk L, Leptien A, Van Wyhe MM, Davis TL, Fermi SJ, Pechler H, Sahyun G, Lopatin M, Wang BY, Wei C, Bartkowiak M, Ginsberg BH, Tamada JA, Pitzer KR. Use of the GlucoWatch biographer in children and adolescents with diabetes. Pediatr Diabetes 2002; 3:127-34. [PMID: 15016152 DOI: 10.1034/j.1399-5448.2002.30302.x] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE This study was done to evaluate the accuracy and safety of measuring glucose with the GlucoWatch biographer in children and adolescents with diabetes. METHODS Accuracy was assessed by comparing biographer glucose measurements with hourly blood glucose measurements using the HemoCue (Aktiebolaget Leo, Helsingborg, Sweden) Photometer for up to 12 h of monitoring. Safety was evaluated by examining the biographer application sites immediately upon removal of the devices, and then at regular intervals. RESULTS Sixty-six subjects each wore three biographers at sites including the forearm, upper arm, leg, and torso. For forearm biographers, the mean absolute relative difference between biographer readings and blood glucose was 21%. Ninety-five per cent of biographer readings fell into the A or B regions of the Clarke error grid, and 97.3% into the A or B regions of the consensus error grid. Data from biographers worn at the alternative sites were similar to data from the forearm biographers. Two strong reactions to the adhesive pad of the biographer AutoSensor were observed. Most skin reactions were mild. CONCLUSIONS The GlucoWatch biographer is well tolerated by children and adolescents with diabetes. Performance is similar when the device is worn at different anatomical sites, and is similar to the performance on the forearm, previously reported in adults.
Collapse
|
7
|
Tamada JA, King CJ. Extraction of carboxylic acids with amine extractants. 2. Chemical interactions and interpretation of data. Ind Eng Chem Res 2002. [DOI: 10.1021/ie00103a036] [Citation(s) in RCA: 240] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
8
|
Tamada JA, Kertes AS, King CJ. Extraction of carboxylic acids with amine extractants. 1. Equilibria and law of mass action modeling. Ind Eng Chem Res 2002. [DOI: 10.1021/ie00103a035] [Citation(s) in RCA: 326] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
9
|
Tamada JA, King CJ. Extraction of carboxylic acids with amine extractants. 3. Effect of temperature, water coextraction, and process considerations. Ind Eng Chem Res 2002. [DOI: 10.1021/ie00103a037] [Citation(s) in RCA: 183] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
10
|
Abstract
Glucose can be extracted through intact skin by electro-osmotic flow (a process called 'reverse iontophoresis') upon the application of a low-level electrical current. Recently we have combined iontophoretic extraction with an in situ glucose sensor in a device called the GlucoWatch biographer. Clinical results with this device show close tracking of blood glucose over a range of 2.2 to 22.2 mmol/l for up to 12 h using a single blood glucose value as calibration. The biographer readings lag behind blood glucose values by an average of 18 min. An analysis of data from 92 diabetic subjects in a controlled clinical setting shows a linear relationship (r=0.88) between GlucoWatch biographer readings and blood glucose. The mean absolute relative difference between the two measurements was 15.6% and more than 96% of the data fell in the (A+B) regions of the Clarke error grid. Similar results have been obtained from subjects using the GlucoWatch biographer in an uncontrolled home environment. The automatic, frequent, and non-invasive measurements obtained with the GlucoWatch biographer provide substantially more information about glucose levels than do the current fingerstick methods. This information can be used for improved decisions about all aspects of diabetes management.
Collapse
Affiliation(s)
- Russell O Potts
- Cygnus, Inc., 400 Penobscot Drive, Redwood City, CA 94063, USA.
| | | | | |
Collapse
|
11
|
Tierney MJ, Tamada JA, Potts RO, Jovanovic L, Garg S. Clinical evaluation of the GlucoWatch biographer: a continual, non-invasive glucose monitor for patients with diabetes. Biosens Bioelectron 2001; 16:621-9. [PMID: 11679237 DOI: 10.1016/s0956-5663(01)00189-0] [Citation(s) in RCA: 181] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
A device providing frequent, automatic, and non-invasive glucose measurements for persons with diabetes has been developed: the GlucoWatch biographer. This device extracts glucose through intact skin via reverse iontophoresis where it is detected by an amperometric biosensor. The biographer can provide glucose readings every 20 min for 12 h. The performance of this device was evaluated in two large clinical studies in a controlled clinical environment (n=231), and the home environment (n=124). Accuracy of the biographer was evaluated by comparing the automatic biographer readings to serial finger-stick blood glucose (BG) measurements. Biographer performance was comparable in both environments. Mean difference between biographer and finger-stick measurements was -0.01 and 0.26 mmol l(-1) for the clinical and home environments, respectively. The mean absolute value of the relative difference was 1.06 and 1.18 mmol l(-1) for the same studies. Correlation coefficient (r) between biographer and finger-stick measurements was 0.85 and 0.80 for the two studies. In both studies, over 94% of the biographer readings were in the clinically acceptable A+B region of the Clarke Error Grid. A slight positive bias is observed for the biographer readings at low BG levels. Biographer accuracy is relatively constant over all rates of BG changes, except when BG decreases more than 10 mmol l(-1) h(-1), which occurred for only 0.2% of points in the home environment study. Biographer precision, as measured by CV%, is approx. 10%. Skin irritation, characterized by erythema and edema, was either non-existent or mild in >90% of subjects and resolved in virtually all subjects without treatment in several days.
Collapse
Affiliation(s)
- M J Tierney
- Cygnus, Inc., 400 Penobscot Drive, 94063, Redwood City, CA 94063, USA.
| | | | | | | | | |
Collapse
|
12
|
Abstract
OBJECTIVE Hypoglycemia is a common acute complication of diabetes therapy. The GlucoWatch biographer provides frequent and automatic glucose measurements with an adjustable low-glucose alarm. We have analyzed the performance of the biographer low-glucose alarm relative to hypoglycemia as defined by blood glucose < or = 3.9 mmol/l. RESEARCH DESIGN AND METHODS The analysis was based on 1,091 biographer uses from four clinical trials. which generated 14,487 paired (biographer and blood glucose) readings. RESULTS The results show that as the low-glucose alert level of the biographer is increased, the number of true positive alerts (alarm sounds and blood glucose < or = 3.9 mmol/l) and false positive alerts (alarm sounds but blood glucose >3.9 mmol/l) increased. When analyzed as a function of varying low-glucose alert levels, the results show receiver operator characteristic curves consistent with a highly useful diagnostic tool. Setting the alert level from 1.1 to 1.7 mmol/l above the level of concern is likely to optimize the trade-off between true positives and false positives for each user. When the same blood glucose data are analyzed for typical monitoring practices (two or four measurements per day), the results show that fewer hypoglycemic events are detected than those detected with the biographer.
Collapse
Affiliation(s)
- K R Pitzer
- Cygnus Incorporated, Redwood City, California 94063, USA.
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Abstract
The GlucoWatch (Cygnus, Inc, Redwood City, CA, USA) biographer provides automatic, frequent and noninvasive blood glucose measurements for up to 12 h. The device extracts glucose through intact skin where it is measured by an amperometric biosensor. Clinical trials in a variety of environments have shown that the biographer provides accurate and precise glucose measurements when compared with serial fingerstick blood glucose measurements. Mean difference between these measurements was 0.26 mmol/L in the home environment (r = 0.80). Over 94% of biographer readings were in the clinically acceptable A+B region of the Clarke Error Grid. A slight positive bias is observed for the biographer readings at low glucose levels. Biographer precision, as measured by coefficient of variation (CV)%, is approximately 10%. The low glucose alert function of the biographer was able to detect up to 75% of hypoglycaemic episodes with a low false alert level. Skin irritation, characterized by erythema and oedema was either nonexistent or mild in over 87% of subjects and resolved in virtually all subjects without treatment in several days. The GlucoWatch biographer has been shown to be a safe and effective method to track glucose level trends and patterns, which should enable improved glycaemic control for many patients.
Collapse
|
14
|
Lu L, Peter SJ, Lyman MD, Lai HL, Leite SM, Tamada JA, Uyama S, Vacanti JP, Langer R, Mikos AG. In vitro and in vivo degradation of porous poly(DL-lactic-co-glycolic acid) foams. Biomaterials 2000; 21:1837-45. [PMID: 10919687 DOI: 10.1016/s0142-9612(00)00047-8] [Citation(s) in RCA: 529] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
This study investigated the in vitro degradation of porous poly(DL-lactic-co-glycolic acid) (PLGA) foams during a 20-week period in pH 7.4 phosphate-buffered saline (PBS) at 37 degrees C and their in vivo degradation following implantation in rat mesentery for up to 8 weeks. Three types of PLGA 85 : 15 and three types of 50 : 50 foams were fabricated using a solvent-casting, particulate-leaching technique. The two types had initial salt weight fraction of 80 and 90%, and a salt particle size of 106-150 microm, while the third type had 90% initial weight fraction of salt in the size range 0-53 microm. The porosities of the resulting foams were 0.82, 0.89, and 0.85 for PLGA 85 : 15, and 0.73, 0.87, and 0.84 for PLGA 50 : 50 foams, respectively. The corresponding median pore diameters were 30, 50, and 17 microm for PLGA 85: 15, and 19, 17, and 17 microm for PLGA 50 : 50. The in vitro and in vivo degradation kinetics of PLGA 85: 15 foams were independent of pore morphology with insignificant variation in foam weight, thickness, pore distribution, compressive creep behavior, and morphology during degradation. The in vitro foam half-lives based on the weight average molecular weight were 11.1 +/- 1.8 (80%, 106-150 microm), 12.0 +/- 2.0 (90%, 106-150 microm), and 11.6 +/- 1.3 (90%, 0-53 microm) weeks, similar to the corresponding values of 9.4 +/- 2.2, 14.3 +/- 1.5, and 13.7 +/- 3.3 weeks for in vivo degradation. In contrast, all PLGA 50 : 50 foams exhibited significant change in foam weight, water absorption, and pore distribution after 6-8 weeks of incubation with PBS. The in vitro foam half-lives were 3.3 +/- 0.3 (80%, 106-150 microm), 3.0 +/- 0.3 (90%, 106-150 microm), and 3.2 +/- 0.1 (90%, 0-53 microm) weeks, and the corresponding in vivo half-lives were 1.9 micro 0.1, 2.2 +/- 0.2, and 2.4 +/- 0.2 weeks. The significantly shorter half-lives of PLGA 50: 50 compared to 85: 15 foams indicated their faster degradation both in vitro and in vivo. In addition, PLGA 50: 50 foams exhibited significantly faster degradation in vivo as compared to in vitro conditions due to an autocatalytic effect of the accumulated acidic degradation products in the medium surrounding the implants. These results suggest that the polymer composition and environmental conditions have significant effects on the degradation rate of porous PLGA foams.
Collapse
Affiliation(s)
- L Lu
- Department of Bioengineering, Rice University, Houston, TX 77005-1892, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Abstract
This study investigated the in vitro degradation of porous poly(L-lactic acid) (PLLA) foams during a 46-week period in pH 7.4 phosphate-buffered saline at 37 degrees C. Four types of PLLA foams were fabricated using a solvent-casting, particulate-leaching technique. The three types had initial salt weight fraction of 70, 80, and 90%, and a salt particle size of 106-150 microm, while the fourth type had 90% initial weight fraction of salt in the size range 0-53 microm. The porosities of the resulting foams were 0.67, 0.79, 0.91, and 0.84, respectively. The corresponding median pore diameters were 33, 52, 91, and 34 microm. The macroscopic degradation of PLLA foams was independent of pore morphology with insignificant variation in foam weight, thickness, pore distribution, compressive creep behavior, and morphology during degradation. However, decrease in melting temperature and slight increase in crystallinity were observed at the end of degradation. The foam half-lives based on the weight average molecular weight were 11.6+/-0.7 (70%, 106-150 microm), 15.8+/-1.2 (80%, 106-150 microm), 21.5+/-1.5 (90%, 106-150 microm), and 43.0+/-2.7 (90%, 0-53 microm) weeks. The thicker pore walls of foams prepared with 70 or 80% salt weight fraction as compared to those with 90% salt weight fraction contributed to an autocatalytic effect resulting in faster foam degradation. Also, the increased pore surface/volume ratio of foams prepared with salt in the range 0-53 microm enhanced the release of degradation products thus diminishing the autocatalytic effect and resulting in slower foam degradation compared to those with salt in the range 106-150 microm. Formation and release of crystalline PLLA particulates occurred for foams fabricated with 90% salt weight fraction at early stages of degradation. These results suggest that the degradation rate of porous foams can be engineered by varying the pore wall thickness and pore surface/volume ratio.
Collapse
Affiliation(s)
- L Lu
- Department of Bioengineering, Rice University, Houston, TX 77005-1892, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Tierney MJ, Garg S, Ackerman NR, Fermi SJ, Kennedy J, Lopatin M, Potts RO, Tamada JA. Effect of acetaminophen on the accuracy of glucose measurements obtained with the GlucoWatch biographer. Diabetes Technol Ther 2000; 2:199-207. [PMID: 11469259 DOI: 10.1089/15209150050025140] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND Improved glycemic control significantly reduces long-term microvascular complications of diabetes mellitus associated with chronic hyperglycemia. The GlucoWatch biographer is designed to facilitate intensive diabetes management by providing automatic, frequent, and noninvasive glucose readings up to three times per hour for as long as 12 hours. METHODS The device extracts glucose through intact skin using reverse iontophoresis and measures the extracted glucose with an electrochemical biosensor. A clinical trial was performed to assess the effect of acetaminophen, a potential interference for traditional blood glucose meters, on the accuracy of the GlucoWatch biographer in adult subjects with diabetes (n = 18). One thousand milligram doses of acetaminophen were administered to subjects in two groups: one to achieve Cmax (peak acetominophen concentration) at the time of biographer calibration and the other to achieve Cmax during the measurement period. The biographer readings were compared to serial fingerstick blood glucose measurements. RESULTS Time profiles over 9 hours show close tracking of the biographer glucose results with fingerstick blood glucose measurements for all groups. The mean difference between the two measurements is between 8 and 12 mg/dL for all groups. The mean absolute value of the relative difference is less than 20%, and more than 93% of the points were in the clinically acceptable (A+B) region of the Clarke Error Grid. No statistically significant differences were found for any accuracy measurement across all groups. CONCLUSIONS The GlucoWatch Biographer provides frequent measurements of glucose over a 12-hour period with high accuracy. No effect of therapeutic dosage of acetaminophen on the accuracy of the glucose readings was found.
Collapse
Affiliation(s)
- M J Tierney
- Cygnus, Inc, Redwood City, California 94063, USA.
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Abstract
CONTEXT Intensive diabetes management using frequent blood glucose measurements to guide therapy has been shown to significantly improve short- and long-term outcomes. Development of a device that makes possible frequent, automatic, painless, and accurate measurements of glucose would facilitate intensive management. OBJECTIVE To determine the accuracy of the GlucoWatch automatic glucose biographer (Cygnus Inc) compared with that of serial blood glucose measurements. DESIGN Multicenter comparative study of the GlucoWatch biographer and the HemoCue blood glucose analyzer (Aktiebolaget Leo) performed between August 29 and October 17, 1998. Participants wore up to 2 biographers during the 15-hour study session and performed 2 fingersticks per hour for comparative blood glucose measurements. The biographers were calibrated with a single HemoCue measurement after a 3-hour warm-up period. Diet and insulin were manipulated to produce a broad glycemic range during the study. SETTING Controlled clinical environment at 2 diabetes centers and 3 contract research organizations in the United States. PARTICIPANTS A total of 92 subjects (mean [SD] age, 42.1 [15.1] years; 59.8% women) with type 1 or 2 diabetes requiring treatment with insulin. MAIN OUTCOME MEASURES Mean error, mean absolute error, correlation, slope, and intercept using Deming regression, and clinical significance of differences between biographer readings and blood glucose measurements using the Clarke error grid. RESULTS Results showed close tracking of blood glucose over a range of 2.2 to 22.2 mmol/L (40-400 mg/dL) for up to 12 hours using a single point calibration. The biographer readings lagged behind serial blood glucose values by a mean of 18 minutes. An analysis of 2167 data pairs shows a linear relationship (r = 0.88; slope = 1.03; intercept = -0.33 mmol/L [-6 mg/dL]) between biographer readings and serial glucose measurements. The mean absolute error between the 2 measurements was 15.6% (mean error [SD], -0.07 [1.82] mmol/L [-1 [33] mg/dL]), and 96.8% of the data fell in the therapeutically relevant regions of the error grid analysis. CONCLUSION These results demonstrate close agreement between GlucoWatch biographer readings and blood glucose measurements using repeated fingerstick blood samples. The automatic, frequent, and noninvasive measurements obtained with the biographer provides more information about glucose levels than the current standard of care.
Collapse
Affiliation(s)
- J A Tamada
- Cygnus Inc, Redwood City, Calif 94063, USA
| | | | | | | | | | | |
Collapse
|
18
|
Garg SK, Potts RO, Ackerman NR, Fermi SJ, Tamada JA, Chase HP. Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes. Diabetes Care 1999; 22:1708-14. [PMID: 10526740 DOI: 10.2337/diacare.22.10.1708] [Citation(s) in RCA: 166] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVE The purpose of this study was to compare measurements of glucose obtained via iontophoretic extraction with the GlucoWatch automatic glucose biographer (Cygnus, Inc., Redwood City, CA) with capillary blood glucose values that were determined 1) in a controlled outpatient clinic setting and 2) in a home setting. RESEARCH DESIGN AND METHODS There were 76 GlucoWatch biographers used on 28 different young adults (21 women and 7 men) with type 1 diabetes (age 30.9 +/- 6.9 years and duration of diabetes 18.4 +/- 8.1 years [mean +/- SD]) in a controlled outpatient clinic setting. Some subjects participated on multiple days. Subjects wore two GlucoWatch biographers, each on the forearm (ventral aspect). Comparisons were made to HemoCue blood glucose analyzer (Aktiebolgat Leo, Helsingborg, Sweden) capillary blood glucose measurements. In addition, GlucoWatch biographers (one each day for 3 consecutive days) were used by 12 subjects (8 women, 4 men) in a home setting. Comparisons were made to capillary blood glucose values determined using the One Touch Profile meter (Johnson & Johnson, New Brunswick, NJ). RESULTS GlucoWatch biographer glucose values correlated well with capillary blood glucose values determined using the HemoCue analyzer in the clinic setting (r = 0.90, 1,554 paired data points) and using the One Touch Profile meter in the home setting (r = 0.85, 204 paired data points). When 36 subjects wore two biographers simultaneously, the correlation between the two biographers was r = 0.94. The error grid analysis demonstrated that > 96% of biographer glucose values determined in the clinic or home setting were in the clinically acceptable A and B regions. CONCLUSIONS This study confirms the accuracy and precision of glucose values as determined using the GlucoWatch biographer in clinic and home settings.
Collapse
Affiliation(s)
- S K Garg
- Department of Pediatrics, Barbara Davis Center for Childhood Diabetes, University of Colorado Health Sciences Center, Denver 80262, USA.
| | | | | | | | | | | |
Collapse
|
19
|
Potts RO, Bommannan D, Wong O, Tamada JA, Riviere JE, Monteiro-Riviere NA. Transdermal peptide delivery using electroporation. Pharm Biotechnol 1997; 10:213-38. [PMID: 9160374 DOI: 10.1007/0-306-46803-4_8] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Affiliation(s)
- R O Potts
- Cygnus, Inc., Redwood City, California 94063, USA
| | | | | | | | | | | |
Collapse
|
20
|
Abstract
Results from the Diabetes Care and Complications Trial show that tight blood glucose control significantly reduces the long-term complications of diabetes mellitus. In that study, frequent self-testing of glucose and insulin administration resulted in a significant reduction in long-term complications. This protocol, however, also resulted in a threefold increase in the frequency of hypoglycaemic incidents. Currently, self-testing requires a drop of blood for each measurement. The pain and inconvenience of self-testing, along with the fear and danger of hypoglycaemia has led to poor patient acceptance of a tight control regimen, despite the clear long-term advantages. A continuously worn, noninvasive method to periodically measure glucose would provide a convenient and comfortable means of frequent self-testing. A continuously worn device could also alert the user of low glucose levels, thereby reducing the incidence of hypoglycaemia. Guy et al. demonstrated a noninvasive method to transport glucose through the skin using low-level electrical current. To provide a quantitative measurement, the flux of glucose extracted across the skin must correlate with serum glucose in a predictive manner. The results presented here show a quantitative relationship between serum and transdermally extracted glucose in diabetics.
Collapse
Affiliation(s)
- J A Tamada
- Cygnus Therapeutic Systems, Redwood City, California 94063, USA
| | | | | |
Collapse
|
21
|
Wu MP, Tamada JA, Brem H, Langer R. In vivo versus in vitro degradation of controlled release polymers for intracranial surgical therapy. J Biomed Mater Res 1994; 28:387-95. [PMID: 8077254 DOI: 10.1002/jbm.820280314] [Citation(s) in RCA: 79] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Intracranial studies to analyze the degradation kinetics of the bioerodible polymer poly[bis(p-carboxyphenoxy)propane-sebacic acid] [p(CPP-SA) 20:80] copolymer wafers were conducted in a rat model. Rats were separated into four groups: those receiving 1) polymer, 2) polymer loaded with the chemotherapeutic agent BCNU, 3) drug-loaded polymer with previous tumor implantation, and 4) polymer and an absorbable hemostatic material. A polymer wafer was surgically implanted into the brain of each animal. Residual polymer was harvested at varying times for chromatographic analysis. In vitro effects of pH, mixing, and water availability on degradation were also studied. The results of in vitro and in vivo studies were compared to understand the behavior of polymers in a clinical setting. We found that degradation of p(CPP-SA) initially occurred more slowly in vivo than in vitro. The presence of BCNU, tumor, and absorbable hemostatic material did not affect the ultimate time of polymer degradation in vivo, and the intrinsic polymer degradation time of 1 mm thick p(CPP-SA) 20:80 disks in vivo was 6-8 weeks.
Collapse
Affiliation(s)
- M P Wu
- Harvard-M.I.T. Division of Health Sciences and Technology, Cambridge 02139
| | | | | | | |
Collapse
|
22
|
Abstract
Degradable polymers are beginning to play an increasing role as materials for environmental and medical applications. Understanding factors that control erosion, such as bond cleavage and the dissolution and diffusion of degradation products, will be critical to the future development of these materials. Erosion kinetics, photomicroscopy, and infrared spectroscopy were used to understand the erosion mechanism of two families of degradable polymers, polyanhydrides and polyesters. Polyanhydrides exhibit behavior more characteristic of surface erosion, whereas the polyesters exhibit bulk erosion patterns. Control of erosion times from a few days to several years can be achieved by a judicious choice of monomer units and bond selection.
Collapse
Affiliation(s)
- J A Tamada
- Massachusetts Institute of Technology, Department of Chemical Engineering, Cambridge 02139
| | | |
Collapse
|
23
|
Abstract
We report a study of the effects of polymer molecular weight on the erosion of polyanhydride copolymer matrices composed of 1,3-bis(p-carboxyphenoxy)-propane (CPP) and sebacic acid (SA) in aqueous solution. The erosion profile characteristically displays an induction period during which the erosion rate is relatively slow. The length of this period depends on the initial molecular weight of the polymer. The induction period may be characterized as a time during which a rapid decrease in polymer molecular weight occurs, the end of this period correlating with the time required for the polymer molecular weight to decrease to below a value of approximately 5000 (MW).
Collapse
Affiliation(s)
- A D'Emanuele
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge 02139
| | | | | | | | | |
Collapse
|
24
|
Sluzky V, Tamada JA, Klibanov AM, Langer R. Kinetics of insulin aggregation in aqueous solutions upon agitation in the presence of hydrophobic surfaces. Proc Natl Acad Sci U S A 1991; 88:9377-81. [PMID: 1946348 PMCID: PMC52720 DOI: 10.1073/pnas.88.21.9377] [Citation(s) in RCA: 376] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
The stability of protein-based pharmaceuticals (e.g., insulin) is important for their production, storage, and delivery. To gain an understanding of insulin's aggregation mechanism in aqueous solutions, the effects of agitation rate, interfacial interactions, and insulin concentration on the overall aggregation rate were examined. Ultraviolet absorption spectroscopy, high-performance liquid chromatography, and quasielastic light scattering analyses were used to monitor the aggregation reaction and identify intermediate species. The reaction proceeded in two stages; insulin stability was enhanced at higher concentration. Mathematical modeling of proposed kinetic schemes was employed to identify possible reaction pathways and to explain greater stability at higher insulin concentration.
Collapse
Affiliation(s)
- V Sluzky
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge 02139
| | | | | | | |
Collapse
|
25
|
Abstract
Biomaterials have made a great impact on medicine. However, numerous challenges remain. This paper discusses three representative areas involving important medical problems. First, drug delivery systems; major considerations include drug-polymer interactions, drug transformation, diffusion properties of drugs and, if degradation occurs, of polymer degradation products through polymer matrices developing a more complete understanding of matrix degradation in the case of erodible polymers and developing new engineered polymers designed for specific purposes such as vaccination or pulsatile release. Second, cell-polymer interactions, including the fate of inert polymers, the use of polymers as templates for tissue regeneration and the study of polymers which aid cell transplantation. Third, orthopaedic biomaterials, including basic research in the behaviour of chondrocytes, osteocytes and connective tissue-free interfaces and applied research involving computer-aided design of biomaterials and the creation of orthopaedic biomaterials.
Collapse
Affiliation(s)
- R Langer
- Massachusetts Institute of Technology, Department of Chemical Engineering, Cambridge 02139
| | | | | | | |
Collapse
|