1
|
Soo JC, Wei CH, Chen JK, Dong GC, Liu ZS, Chou HC, Perez RL, Adhikari A, Chen YC. Assessment of inhalation exposure to microplastic particles when disposable masks are repeatedly used. Sci Total Environ 2024; 912:169428. [PMID: 38104815 DOI: 10.1016/j.scitotenv.2023.169428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 12/12/2023] [Accepted: 12/14/2023] [Indexed: 12/19/2023]
Abstract
Wearing masks to prevent infectious diseases, especially during the COVID-19 pandemic, is common. However, concerns arise about inhalation exposure to microplastics (MPs) when disposable masks are improperly reused. In this study, we assessed whether disposable masks release inhalable MPs when reused in simulated wearing conditions. All experiments were conducted using a controlled test chamber setup with a constant inspiratory flow. Commercially available medical masks with a three-layer material, composition comprising polypropylene (PP in the outer and middle layers) and polyethylene (PE in the inner layer), were used as the test material. Brand-new masks with and without hand rubbing, as well as reused medical masks, were tested. Physical properties (number, size, and shape) and chemical composition (polymers) were identified using various analytical techniques such as fluorescence staining, fluorescence microscopy, and micro-Fourier Transform Infrared Spectroscopy (μFTIR). Scanning Electron Microscopy (SEM) was used to scrutinize the surface structure of reused masks across different layers, elucidating the mechanism behind the MP generation. The findings revealed that brand-new masks subjected to hand rubbing exhibited a higher cumulative count of MPs, averaging approximately 1.5 times more than those without hand rubbing. Fragments remained the predominant shape across all selected size classes among the released MPs from reused masks, primarily through a physical abrasion mechanism, accounting for >90 % of the total MPs. The numbers of PE particles were higher than PP particles, indicating that the inner layer of the mask contributed more inhalable MPs than the middle and outer layers combined. The released MPs from reused masks reached their peak after 8 h of wearing. This implies that regularly replacing masks serves as a preventive measure and mitigates associated health risks of inhalation exposure to MPs.
Collapse
Affiliation(s)
- Jhy-Charm Soo
- Department of Biostatistics, Epidemiology and Environmental Health Sciences, Jiann-Ping Hsu College Public Health, Georgia Southern University, Statesboro, GA 30460, USA
| | - Chun-Hsuan Wei
- National Institute of Environmental Health Sciences, National Health Research Institutes, Miaoli, Taiwan
| | - Jen-Kun Chen
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan
| | - Guo-Chung Dong
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan
| | - Zhen-Shu Liu
- Department of Safety, Health and Environmental Engineering, Ming Chi University of Technology, New Taipei City, Taiwan
| | - Hsiu-Chuan Chou
- Institute of Analytical and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan
| | - Rocio L Perez
- Department of Chemistry, Biochemistry and Physics, College of Science and Mathematics, Georgia Southern University, Statesboro, GA 30460, USA
| | - Atin Adhikari
- Department of Biostatistics, Epidemiology and Environmental Health Sciences, Jiann-Ping Hsu College Public Health, Georgia Southern University, Statesboro, GA 30460, USA
| | - Yu-Cheng Chen
- National Institute of Environmental Health Sciences, National Health Research Institutes, Miaoli, Taiwan; Department of Occupational Safety and Health, China Medical University, 91 Hsueh-Shih Road, Taichung, Taiwan; Department of Safety, Health and Environmental Engineering, National United University, Miaoli, Taiwan.
| |
Collapse
|
2
|
Myers WR, Yang W, Ryan KJ, Bergman MS, M Fisher E, Soo JC, Zhuang Z. Total outward leakage of half-mask respirators and surgical masks used for source control. J Occup Environ Hyg 2023; 20:610-620. [PMID: 37682702 DOI: 10.1080/15459624.2023.2257254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/10/2023]
Abstract
Both respirators and surgical masks (SM) are used as source control devices. During the COVID-19 pandemic, there was much interest in understanding the extent of particle total outward leakage (TOL) from these devices. The objective of this study was to quantify the TOL for five categories of devices: SMs, National Institute for Occupational Safety and Health (NIOSH) Approved N95 filtering facepiece respirators (FFRs) without exhalation valves, NIOSH Approved N95 FFRs with exhalation valves (N95 FFRV), NIOSH Approved elastomeric half-mask respirators (EHMRs) with exhalation valves, and NIOSH Approved EHMRs with an SM covering the exhalation valve (EHMRSM). A benchtop test system was designed to test two models of each device category. Each device was mounted on a headform at three faceseal levels (0% faceseal, 50% faceseal, and 100% faceseal). At each faceseal level, the TOL was assessed at three flow rates of minute ventilations of 17, 28, and 39 L/min. The experimental design was a split-split-plot configuration. Device type, faceseal level, flow rate, and the interaction of device type and faceseal level were found to have a significant effect (p - value < 0.05) on the TOL. This study found that the N95 FFRs without exhalation valves had the lowest mean TOL. The SMs had about three times higher TOL than the N95 FFRs without exhalation valves. The TOL of the N95 FFRV was comparable to that of the SM at 0% and 50% faceseal on average overall conditions, but the N95 FFRV had a significantly higher TOL than the SM at a 100% faceseal. The EHMRs had the highest TOL because of the exhalation valve. Using an SM to cover the exhalation valve did not improve the EHMRs' efficiency in mitigating the TOL. Caution should be exercised when using N95 FFRVs as a source control measure against respiratory activities with heavy work rates, such as performing CPR. Results of this study showed that reduced faceseal leakage for N95 FFRs and SMs improves source control.
Collapse
Affiliation(s)
- Warren R Myers
- Department of Industrial and Management Systems Engineering, West Virginia University, Morgantown, West Virginia
| | - Weihua Yang
- Department of Industrial and Management Systems Engineering, West Virginia University, Morgantown, West Virginia
| | - Kenneth J Ryan
- Department of Statistics, West Virginia University, Morgantown, West Virginia
| | - Michael S Bergman
- Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, Pennsylvania
| | - Edward M Fisher
- Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, Pennsylvania
| | - Jhy-Charm Soo
- Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, Pennsylvania
| | - Ziqing Zhuang
- Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, Pennsylvania
| |
Collapse
|
3
|
Hsu CY, Soo JC, Lin SL, Wu CD, Chi KH, Hsu WC, Tseng CC, Chen YC. Using cluster algorithms with a machine learning technique and PMF models to quantify local-specific origins of PM 2.5 and associated metals in Taiwan. Environ Pollut 2023; 316:120652. [PMID: 36375582 DOI: 10.1016/j.envpol.2022.120652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 11/07/2022] [Accepted: 11/10/2022] [Indexed: 06/16/2023]
Abstract
The influence of long-range transport (LRT) of air pollutants on neighboring regions and countries has been documented. The magnitude of LRT aerosols and related constituents can misdirect control strategies for local air quality management. In this study, we aimed to quantify PM2.5 (diameter less than 2.5 μm, PM2.5) and associated metals derived from local sources and LRT in different geographic locations in Taiwan using advanced receptor models. We collected daily PM2.5 samples (n = ∼1000) and analyzed 28 metals every three days from 2016 to 2018 in the northern, central-south, eastern, and southern areas of Taiwan. We first used a machine learning technique with a cluster algorithm coupled with a backward trajectory to classify local, regional, and LRT-related aerosols. We then quantified the source contributions with a positive matrix factorization (PMF) model for Taiwan weighted by region-specific populations. The northern and eastern regions were found to be more vulnerable to LRT-related PM2.5 and metals than the central-south and southern regions in Taiwan. The LRT increased Pb and As concentrations by 90-200% and ∼40% in the northern and central-south regions. Ambient PM2.5-metals mainly originated from local traffic-related emissions in the northern, central-south, and southern regions, whereas oil combustion was the primary source of PM2.5-metals in the eastern region. By subtracting the influence from the LRT, the contributions of domestic emission sources to ambient PM2.5 metals in Taiwan were 35% from traffic-related emission, 17% from non-ferrous metallurgy, 13% from iron ore and steel factories, 12% from coal combustion, 12% from oil combustion, 10% from incinerator emissions, and <1% from cement manufacturing emissions. This study proposed an advanced method for refining local source contributions to ambient PM2.5 metals in Taiwan, which provides useful information on regional control strategies.
Collapse
Affiliation(s)
- Chin-Yu Hsu
- Department of Safety, Health and Environmental Engineering, Ming Chi University of Technology, 84 Gungjuan Rd., Taishan Dist., New Taipei City, Taiwan; Center for Environmental Sustainability and Human Health, Ming Chi University of Technology, 84 Gungjuan Rd., Taishan Dist., New Taipei City, Taiwan
| | - Jhy-Charm Soo
- Department of Biostatistics, Epidemiology and Environmental Health Sciences, Jiann Ping Hsu College Public Health, Georgia Southern University, Statesboro, GA, USA
| | - Sheng-Lun Lin
- School of Mechanical Engineering, Beijing Institute of Technology, Beijing, China
| | - Chih-Da Wu
- National Institute of Environmental Health Sciences, National Health Research Institutes, 35 Keyan Road, Zhunan Town, Miaoli, Taiwan; Department of Geomatics, National Cheng Kung University, Taiwan
| | - Kai Hsien Chi
- Institute of Environmental and Occupational Health Sciences, National Yang-Ming University, 1 Daxue Road., East District., Tainan City, Taiwan
| | - Wen-Chang Hsu
- Department of Civil Engineering and Resource Management, Dahan Institute of Technology, 1 Shuren Street, Xincheng Township, Hualien County, 971, Taiwan
| | - Chun-Chieh Tseng
- Department of Public Health, Tzu Chi University, 701, Zhongyang Road, Hualien City, Hualien County, Taiwan
| | - Yu-Cheng Chen
- National Institute of Environmental Health Sciences, National Health Research Institutes, 35 Keyan Road, Zhunan Town, Miaoli, Taiwan; Department of Occupational Safety and Health, China Medical University, 91 Hsueh-Shih Road, Taichung, Taiwan; Research Center for Environmental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan.
| |
Collapse
|
4
|
O'Brien DC, Lee EG, Soo JC, Friend S, Callaham S, Carr MM. Surgical Team Exposure to Cautery Smoke and Its Mitigation during Tonsillectomy. Otolaryngol Head Neck Surg 2020; 163:508-516. [PMID: 32450780 DOI: 10.1177/0194599820917394] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVES To assess the exposure of surgical personnel to known carcinogens during pediatric tonsillectomy and adenoidectomy (T&A) and compare the efficacy of surgical smoke evacuation systems during T&A. STUDY DESIGN Prospective, case series. SETTING Tertiary children's hospital. SUBJECTS AND METHODS The present study assessed operating room workers' exposure to chemical compounds and aerosolized particulates generated during T&A. We also investigated the effect of 3 different smoke-controlling methods: smoke-evacuator pencil cautery (SE), cautery with suction held by an assistant (SA), and cautery without suction (NS). RESULTS Thirty cases were included: 12 in the SE group, 9 in SA, and 9 in NS. The chemical exposure levels were lower than or similar to baseline background concentrations, with the exception of methylene chloride and acetaldehyde. Within the surgical plume, none of the chemical compounds exceeded the corresponding occupational exposure limit (OEL). The mean particulate number concentration in the breathing zone during tonsillectomy was 508 particles/cm3 for SE compared to 1661 particles/cm3 for SA and 8208 particles/cm3 for NS cases. NS was significantly different compared to the other two methods (P = .0009). CONCLUSIONS Although the exposure levels to chemicals were considerably lower than the OELs, continuous exposures to these chemicals could cause adverse health effects to surgical personnel. These findings suggest that the use of a smoke-evacuator pencil cautery or an attentive assistant with handheld suction would reduce exposure levels to the aerosolized particles during routine T&A, compared to the use of cautery without suction.
Collapse
Affiliation(s)
- Daniel C O'Brien
- Department of Otolaryngology Head and Neck Surgery, University of West Virginia, Morgantown, West Virginia, USA
| | - Eun Gyung Lee
- Health Effects Laboratory Division, Exposure Assessment Branch, National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA
| | - Jhy-Charm Soo
- Health Effects Laboratory Division, Exposure Assessment Branch, National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA
| | - Sherri Friend
- Health Effects Laboratory Division, Pathology and Physiology Research Branch, National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA
| | - Sarah Callaham
- School of Medicine, West Virginia University, Morgantown, West Virginia, USA
| | - Michele M Carr
- Department of Otolaryngology Head and Neck Surgery, University of West Virginia, Morgantown, West Virginia, USA
| |
Collapse
|
5
|
Carr MM, Patel VA, Soo JC, Friend S, Lee EG. Effect of Electrocautery Settings on Particulate Concentrations in Surgical Plume during Tonsillectomy. Otolaryngol Head Neck Surg 2020; 162:867-872. [PMID: 32228131 DOI: 10.1177/0194599820914275] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVES To describe the effect of monopolar electrocautery (EC) settings on surgical plume particulate concentration during pediatric tonsillectomy. STUDY DESIGN Cross-sectional study. SETTING Tertiary medical center. SUBJECTS AND METHODS During total tonsillectomy exclusively performed with EC, air was sampled with a surgeon-worn portable particle counter. The airborne mean and maximum particle concentrations were compared for tonsillectomy performed with EC at 12 W vs 20 W, with smoke evacuation system (SES) and no smoke evacuation (NS). RESULTS A total of 36 children were included in this analysis: 9 cases with EC at 12 W and SES (12SES), 9 cases with EC at 20 W and SES (20SES), 9 cases with EC at 12 W without SES (12NS), and 9 cases with EC at 20 W without SES (20NS). Mean particle number concentration in the breathing zone during tonsillectomy was 1661 particles/cm3 for 12SES, 5515 particles/cm3 for 20SES, 8208 particles/cm3 for 12NS, and 78,506 particles/cm3 for 20NS. There was a statistically significant difference in the particle number concentrations among the 4 groups. The correlation between the particle number concentration and EC time was either moderate (for 12SES) or negative (for remaining groups). CONCLUSION Airborne particle concentrations during tonsillectomy are over 9.5 times higher when EC is set at 20 W vs 12 W with NS, which is mitigated to 3.3 times with SES. Applying lower EC settings with SES during pediatric tonsillectomy significantly reduces surgical plume exposure for patients, surgeons, and operating room personnel, which is a well-known occupational health hazard.
Collapse
Affiliation(s)
- Michele M Carr
- Department of Otolaryngology-Head and Neck Surgery, West Virginia University, Morgantown, West Virginia, USA
| | - Vijay A Patel
- Department of Otolaryngology, The Pennsylvania State University, Hershey, Pennsylvania, USA
| | - Jhy-Charm Soo
- National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA
| | - Sherri Friend
- National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA
| | - Eun Gyung Lee
- National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA
| |
Collapse
|
6
|
Soo JC, Lebouf RF, Chisholm WP, Nelson J, Roberts J, Kashon ML, Lee EG, Harper M. Evaluation of Sorbent Sampling and Analysis Procedures for Acetone in Workplace Air: Variations of Concentration and Relative Humidity. Ann Work Expo Health 2020; 64:96-105. [PMID: 31786604 DOI: 10.1093/annweh/wxz087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 08/22/2019] [Accepted: 10/30/2019] [Indexed: 11/14/2022] Open
Abstract
This study experimentally evaluates the performance of different sorbent tubes for sampling acetone vapor in workplace air. A dynamic atmosphere system produced an acetone alone and a mixture with other analytes containing ~73, 483, and 1898 µg acetone mass loading at 25, 50, and 75% relative humidity (RH) at 25°C. Sorbent samples were analyzed in accordance with OSHA Method 69 (Carbosieve S-III) and NMAM 1501, modified to use Anasorb 747 sorbent. Both methods were modified to include the additional analytes. Additional extraction procedures with and without 1% dimethylformamide and anhydrous magnesium sulfate were included in the modified NMAM 1501 using Anasorb 747. Silica gel sorbent tubes analyzed according to NMAM 2027 were included. There were significant reductions in the recovery of acetone from both Anasorb 747 and Carbosieve S-III collected from air at 75% RH, relative to collection at 25 or 50% RH at very low loading compared with that of samples collected at mid to high loading. Silica gel provided a consistent recovery of acetone at all RHs and in the presence of other chemical interferences at 75% RH. The likely cause of mass dependence may arise from the humidity effect on acetone adsorption onto both beaded active carbon and carbon molecular sieve either in sampling or in analysis. The present study confirms not only previous observations but also adds to the literature showing carbonaceous sorbents are not well suited for sampling ketones at high humidity and low concentration.
Collapse
Affiliation(s)
- Jhy-Charm Soo
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health (NIOSH), Centers for Disease Control and Prevention (CDC), MS, Morgantown, WV, USA
| | - Ryan F Lebouf
- Respiratory Health Division, NIOSH, CDC, Morgantown, WV, USA
| | - William P Chisholm
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health (NIOSH), Centers for Disease Control and Prevention (CDC), MS, Morgantown, WV, USA
| | - John Nelson
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health (NIOSH), Centers for Disease Control and Prevention (CDC), MS, Morgantown, WV, USA
| | - Jennifer Roberts
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health (NIOSH), Centers for Disease Control and Prevention (CDC), MS, Morgantown, WV, USA
| | - Michael L Kashon
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health (NIOSH), Centers for Disease Control and Prevention (CDC), MS, Morgantown, WV, USA
| | - Eun Gyung Lee
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health (NIOSH), Centers for Disease Control and Prevention (CDC), MS, Morgantown, WV, USA
| | - Martin Harper
- Zefon International, Inc., Ocala, FL, USA
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, FL, USA
| |
Collapse
|
7
|
Sisler JD, Shaffer J, Soo JC, LeBouf RF, Harper M, Qian Y, Lee T. In vitro toxicological evaluation of surgical smoke from human tissue. J Occup Med Toxicol 2018; 13:12. [PMID: 29619075 PMCID: PMC5879936 DOI: 10.1186/s12995-018-0193-x] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Accepted: 03/21/2018] [Indexed: 01/01/2023] Open
Abstract
Background Operating room personnel have the potential to be exposed to surgical smoke, the by-product of using electrocautery or laser surgical device, on a daily basis. Surgical smoke is made up of both biological by-products and chemical pollutants that have been shown to cause eye, skin and pulmonary irritation. Methods In this study, surgical smoke was collected in real time in cell culture media by using an electrocautery surgical device to cut and coagulate human breast tissues. Airborne particle number concentration and particle distribution were determined by direct reading instruments. Airborne concentration of selected volatile organic compounds (VOCs) were determined by evacuated canisters. Head space analysis was conducted to quantify dissolved VOCs in cell culture medium. Human small airway epithelial cells (SAEC) and RAW 264.7 mouse macrophages (RAW) were exposed to surgical smoke in culture media for 24 h and then assayed for cell viability, lactate dehydrogenase (LDH) and superoxide production. Results Our results demonstrated that surgical smoke-generated from human breast tissues induced cytotoxicity and LDH increases in both the SAEC and RAW. However, surgical smoke did not induce superoxide production in the SAEC or RAW. Conclusion These data suggest that the surgical smoke is cytotoxic in vitro and support the previously published data that the surgical smoke may be an occupational hazard to healthcare workers.
Collapse
Affiliation(s)
- Jennifer D Sisler
- 1Pathology and Physiology Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1095 Willowdale Road, Morgantown, West Virginia 26505 USA
| | - Justine Shaffer
- 1Pathology and Physiology Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1095 Willowdale Road, Morgantown, West Virginia 26505 USA
| | - Jhy-Charm Soo
- 2Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1095 Willowdale Road, Morgantown, West Virginia 26505 USA
| | - Ryan F LeBouf
- 3Field Study Branch, Respiratory Health Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1095 Willowdale Road, Morgantown, West Virginia 26505 USA
| | - Martin Harper
- 2Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1095 Willowdale Road, Morgantown, West Virginia 26505 USA.,Zefon International, Inc., 5350 SW 1st Lane, Ocala, FL USA.,5Department of Environmental Engineering Sciences, University of Florida, Gainesville, FL USA
| | - Yong Qian
- 1Pathology and Physiology Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1095 Willowdale Road, Morgantown, West Virginia 26505 USA
| | - Taekhee Lee
- 2Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1095 Willowdale Road, Morgantown, West Virginia 26505 USA
| |
Collapse
|
8
|
Lee T, Soo JC, LeBouf RF, Burns D, Schwegler-Berry D, Kashon M, Bowers J, Harper M. Surgical smoke control with local exhaust ventilation: Experimental study. J Occup Environ Hyg 2018; 15:341-350. [PMID: 29283318 PMCID: PMC6460469 DOI: 10.1080/15459624.2017.1422082] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
This experimental study aimed to evaluate airborne particulates and volatile organic compounds (VOCs) from surgical smoke when a local exhaust ventilation (LEV) system is in place. Surgical smoke was generated from human tissue in an unoccupied operating room using an electrocautery surgical device for 15 min with 3 different test settings: (1) without LEV control; (2) control with a wall irrigation suction unit with an in-line ultra-low penetration air filter; and (3) control with a smoke evacuation system. Flow rate of LEVs was approximately 35 L/min and suction was maintained within 5 cm of electrocautery interaction site. A total of 6 experiments were conducted. Particle number and mass concentrations were measured using direct reading instruments including a condensation particle counter (CPC), a light-scattering laser photometer (DustTrak DRX), a scanning mobility particle sizer (SMPS), an aerodynamic particle sizer (APS), and a viable particle counter. Selected VOCs were collected using evacuated canisters using grab, personal and area sampling techniques. The largest average particle and VOCs concentrations were found in the absence of LEV control followed by LEV controls. Average ratios of LEV controls to without LEV control ranged 0.24-0.33 (CPC), 0.28-0.39 (SMPS), 0.14-0.31 (DustTrak DRX), and 0.26-0.55 (APS). Ethanol and isopropyl alcohol were dominant in the canister samples. Acetaldehyde, acetone, acetonitrile, benzene, hexane, styrene, and toluene were detected but at lower concentrations (<500 μg/m3) and concentrations of the VOCs were much less than the National Institute for Occupational Safety and Health recommended exposure limit values. Utilization of the LEVs for surgical smoke control can significantly reduce but not completely eliminate airborne particles and VOCs.
Collapse
Affiliation(s)
- Taekhee Lee
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| | - Jhy-Charm Soo
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| | - Ryan F. LeBouf
- Field Study Branch Respiratory Health Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| | - Dru Burns
- Field Study Branch Respiratory Health Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| | - Diane Schwegler-Berry
- Pathology and Physiology Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| | - Michael Kashon
- Biostatistics and Epidemiology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| | - Jay Bowers
- West Virginia University Ruby Memorial Hospital, Morgantown, West Virginia
| | - Martin Harper
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| |
Collapse
|
9
|
Soo JC, Gyung Lee E, LeBouf RF, Kashon ML, Chisholm W, Harper M. Evaluation of a portable gas chromatograph with photoionization detector under variations of VOC concentration, temperature, and relative humidity. J Occup Environ Hyg 2018; 15:351-360. [PMID: 29333991 PMCID: PMC6379918 DOI: 10.1080/15459624.2018.1426860] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The objective of this present study was to evaluate the performance of a portable gas chromatograph-photoionization detector (GC-PID), under various test conditions to determine if it could be used in occupational settings. A mixture of 7 volatile organic compounds (VOCs)-acetone, ethylbenzene, methyl isobutyl ketone, toluene, m-xylene, p-xylene, and o-xylene-was selected because its components are commonly present in paint manufacturing industries. A full-factorial combination of 4 concentration levels (exposure scenarios) of VOC mixtures, 3 different temperatures (25°C, 30°C, and 35°C), and 3 relative humidities (RHs; 25%, 50%, and 75%) was conducted in a full-size controlled environmental chamber. Three repetitions were conducted for each test condition allowing for estimation of accuracy. Time-weighted average exposure data were collected using solid sorbent tubes (Anasorb 747, SKC Inc.) as the reference sampling medium. Calibration curves of Frog-4000 using the dry gases showed R2 > 0.99 for all analytes except for toluene (R2 = 0.97). Frog-4000 estimates within a test condition showed good consistency for the performance of repeated measurement. However, there was ∼41-64% reduction in the analysis of polar acetone with 75% RH relative to collection at 25% RH. Although Frog-4000 results correlated well with solid sorbent tubes (r = 0.808-0.993, except for toluene) most of the combinations regardless of analyte did not meet the <25% accuracy criterion recommended by NIOSH. The effect of chromatographic co-elution can be seen with m, p-xylene when the results are compared to the sorbent tube sampling technique with GC-flame ionization detector. The results indicated an effect of humidity on the quantification of the polar compounds that might be attributed to the pre-concentrator placed in the selected GC-PID. Further investigation may resolve the humidity effect on sorbent trap with micro GC pre-concentrator when water vapor is present. Although this instrument does not fulfill the accuracy criterion specified in the NIOSH technical report No. 2012-162, it can be used as a screening tool for range finding monitoring with dry gases calibration in the occupational setting rather than compliance monitoring.
Collapse
Affiliation(s)
- Jhy-Charm Soo
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| | - Eun Gyung Lee
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| | - Ryan F. LeBouf
- Respiratory Health Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| | - Michael L. Kashon
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| | - William Chisholm
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| | - Martin Harper
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida
| |
Collapse
|
10
|
Woodall GM, Hoover MD, Williams R, Benedict K, Harper M, Soo JC, Jarabek AM, Stewart MJ, Brown JS, Hulla JE, Caudill M, Clements AL, Kaufman A, Parker AJ, Keating M, Balshaw D, Garrahan K, Burton L, Batka S, Limaye VS, Hakkinen PJ, Thompson B. Interpreting Mobile and Handheld Air Sensor Readings in Relation to Air Quality Standards and Health Effect Reference Values: Tackling the Challenges. Atmosphere (Basel) 2017; 8:182. [PMID: 29093969 PMCID: PMC5662140 DOI: 10.3390/atmos8100182] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The US Environmental Protection Agency (EPA) and other federal agencies face a number of challenges in interpreting and reconciling short-duration (seconds to minutes) readings from mobile and handheld air sensors with the longer duration averages (hours to days) associated with the National Ambient Air Quality Standards (NAAQS) for the criteria pollutants-particulate matter (PM), ozone, carbon monoxide, lead, nitrogen oxides, and sulfur oxides. Similar issues are equally relevant to the hazardous air pollutants (HAPs) where chemical-specific health effect reference values are the best indicators of exposure limits; values which are often based on a lifetime of continuous exposure. A multi-agency, staff-level Air Sensors Health Group (ASHG) was convened in 2013. ASHG represents a multi-institutional collaboration of Federal agencies devoted to discovery and discussion of sensor technologies, interpretation of sensor data, defining the state of sensor-related science across each institution, and provides consultation on how sensors might effectively be used to meet a wide range of research and decision support needs. ASHG focuses on several fronts: improving the understanding of what hand-held sensor technologies may be able to deliver; communicating what hand-held sensor readings can provide to a number of audiences; the challenges of how to integrate data generated by multiple entities using new and unproven technologies; and defining best practices in communicating health-related messages to various audiences. This review summarizes the challenges, successes, and promising tools of those initial ASHG efforts and Federal agency progress on crafting similar products for use with other NAAQS pollutants and the HAPs. NOTE: The opinions expressed are those of the authors and do not necessary represent the opinions of their Federal Agencies or the US Government. Mention of product names does not constitute endorsement.
Collapse
Affiliation(s)
- George M. Woodall
- Environmental Protection Agency, Research Triangle Park, NC 27711, USA
| | - Mark D. Hoover
- National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA
| | - Ronald Williams
- Environmental Protection Agency, Research Triangle Park, NC 27711, USA
| | - Kristen Benedict
- Environmental Protection Agency, Research Triangle Park, NC 27711, USA
| | - Martin Harper
- National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA
| | - Jhy-Charm Soo
- National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA
| | - Annie M. Jarabek
- Environmental Protection Agency, Research Triangle Park, NC 27711, USA
| | | | - James S. Brown
- Environmental Protection Agency, Research Triangle Park, NC 27711, USA
| | | | - Motria Caudill
- Agency for Toxic Substances and Disease Registry, Atlanta, GA 30329, USA
| | | | - Amanda Kaufman
- Environmental Protection Agency, Research Triangle Park, NC 27711, USA
| | - Alison J. Parker
- ORISE Fellow hosted by U.S. Environmental Protection Agency, Washington, DC 20004, USA
| | - Martha Keating
- Environmental Protection Agency, Research Triangle Park, NC 27711, USA
| | - David Balshaw
- National Institute for Environmental Health Sciences, Research Triangle Park, NC 27709, USA
| | - Kevin Garrahan
- Environmental Protection Agency, Washington, DC 20004, USA
| | - Laureen Burton
- Environmental Protection Agency, Washington, DC 20004, USA
| | - Sheila Batka
- Environmental Protection Agency, Chicago, IL 60605, USA
| | | | | | - Bob Thompson
- Environmental Protection Agency, Research Triangle Park, NC 27711, USA
| |
Collapse
|
11
|
Soo JC, Lee T, Chisholm WP, Farcas D, Schwegler-Berry D, Harper M. Treated and untreated rock dust: Quartz content and physical characterization. J Occup Environ Hyg 2016; 13:D201-7. [PMID: 27314444 PMCID: PMC5009645 DOI: 10.1080/15459624.2016.1200195] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Rock dusting is used to prevent secondary explosions in coal mines, but inhalation of rock dusts can be hazardous if the crystalline silica (e.g., quartz) content in the respirable fraction is high. The objective of this study is to assess the quartz content and physical characteristics of four selected rock dusts, consisting of limestone or marble in both treated (such as treatment with stearic acid or stearates) and untreated forms. Four selected rock dusts (an untreated and treated limestone and an untreated and treated marble) were aerosolized in an aerosol chamber. Respirable size-selective sampling was conducted along with particle size-segregated sampling using a Micro-Orifice Uniform Deposit Impactor. Fourier Transform Infrared spectroscopy and scanning electron microscopy with energy-dispersive X-ray (SEM-EDX) analyses were used to determine quartz mass and particle morphology, respectively. Quartz percentage in the respirable dust fraction of untreated and treated forms of the limestone dust was significantly higher than in bulk samples, but since the bulk percentage was low the enrichment factor would not have resulted in any major change to conclusions regarding the contribution of respirable rock dust to the overall airborne quartz concentration. The quartz percentage in the marble dust (untreated and treated) was very low and the respirable fractions showed no enrichment. The spectra from SEM-EDX analysis for all materials were predominantly from calcium carbonate, clay, and gypsum particles. No free quartz particles were observed. The four rock dusts used in this study are representative of those presented for use in rock dusting, but the conclusions may not be applicable to all available materials.
Collapse
Affiliation(s)
- Jhy-Charm Soo
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, USA
| | - Taekhee Lee
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, USA
| | - William P. Chisholm
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, USA
| | - Daniel Farcas
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, USA
| | - Diane Schwegler-Berry
- Pathology and Physiology Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, USA
| | - Martin Harper
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, USA
| |
Collapse
|
12
|
Farcas D, Lee T, Chisholm WP, Soo JC, Harper M. Replacement of filters for respirable quartz measurement in coal mine dust by infrared spectroscopy. J Occup Environ Hyg 2016; 13:D16-22. [PMID: 26375614 PMCID: PMC4706796 DOI: 10.1080/15459624.2015.1091962] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
The objective of this article is to compare and characterize nylon, polypropylene (PP), and polyvinyl chloride (PVC) membrane filters that might be used to replace the vinyl/acrylic co-polymer (DM-450) filter currently used in the Mine Safety and Health Administration (MSHA) P-7 method (Quartz Analytical Method) and the National Institute for Occupational Safety and Health (NIOSH) Manual of Analytical Methods 7603 method (QUARTZ in coal mine dust, by IR re-deposition). This effort is necessary because the DM-450 filters are no longer commercially available. There is an impending shortage of DM-450 filters. For example, the MSHA Pittsburgh laboratory alone analyzes annually approximately 15,000 samples according to the MSHA P-7 method that requires DM-450 filters. Membrane filters suitable for on-filter analysis should have high infrared (IR) transmittance in the spectral region 600-1000 cm(-1). Nylon (47 mm, 0.45 µm pore size), PP (47 mm, 0.45 µm pore size), and PVC (47 mm, 5 µm pore size) filters meet this specification. Limits of detection and limits of quantification were determined from Fourier transform infrared spectroscopy (FTIR) measurements of blank filters. The average measured quartz mass and coefficient of variation were determined from test filters spiked with respirable α-quartz following MSHA P-7 and NIOSH 7603 methods. Quartz was also quantified in samples of respirable coal dust on each test filter type using the MSHA and NIOSH analysis methods. The results indicate that PP and PVC filters may replace the DM-450 filters for quartz measurement in coal dust by FTIR. PVC filters of 5 µm pore size seemed to be suitable replacement although their ability to retain small particulates should be checked by further experiment.
Collapse
Affiliation(s)
- Daniel Farcas
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, 26505 USA
| | - Taekhee Lee
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, 26505 USA
| | - William P. Chisholm
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, 26505 USA
| | - Jhy-Charm Soo
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, 26505 USA
| | - Martin Harper
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, 26505 USA
| |
Collapse
|
13
|
Soo JC, Monaghan K, Lee T, Kashon M, Harper M. Air sampling filtration media: Collection efficiency for respirable size-selective sampling. Aerosol Sci Technol 2016; 50:76-87. [PMID: 26834310 PMCID: PMC4729392 DOI: 10.1080/02786826.2015.1128525] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
The collection efficiencies of commonly used membrane air sampling filters in the ultrafine particle size range were investigated. Mixed cellulose ester (MCE; 0.45, 0.8, 1.2, and 5 μm pore sizes), polycarbonate (0.4, 0.8, 2, and 5 μm pore sizes), polytetrafluoroethylene (PTFE; 0.45, 1, 2, and 5 μm pore sizes), polyvinyl chloride (PVC; 0.8 and 5 μm pore sizes), and silver membrane (0.45, 0.8, 1.2, and 5 μm pore sizes) filters were exposed to polydisperse sodium chloride (NaCl) particles in the size range of 10-400 nm. Test aerosols were nebulized and introduced into a calm air chamber through a diffusion dryer and aerosol neutralizer. The testing filters (37 mm diameter) were mounted in a conductive polypropylene filter-holder (cassette) within a metal testing tube. The experiments were conducted at flow rates between 1.7 and 11.2 l min-1. The particle size distributions of NaCl challenge aerosol were measured upstream and downstream of the test filters by a scanning mobility particle sizer (SMPS). Three different filters of each type with at least three repetitions for each pore size were tested. In general, the collection efficiency varied with airflow, pore size, and sampling duration. In addition, both collection efficiency and pressure drop increased with decreased pore size and increased sampling flow rate, but they differed among filter types and manufacturer. The present study confirmed that the MCE, PTFE, and PVC filters have a relatively high collection efficiency for challenge particles much smaller than their nominal pore size and are considerably more efficient than polycarbonate and silver membrane filters, especially at larger nominal pore sizes.
Collapse
Affiliation(s)
- Jhy-Charm Soo
- Health Effects Laboratory Division, Exposure Assessment Branch, National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA
| | - Keenan Monaghan
- Health Effects Laboratory Division, Exposure Assessment Branch, National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA
| | - Taekhee Lee
- Health Effects Laboratory Division, Exposure Assessment Branch, National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA
| | - Mike Kashon
- Health Effects Laboratory Division, Biostatistics and Epidemiology Branch, National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA
| | - Martin Harper
- Health Effects Laboratory Division, Exposure Assessment Branch, National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA
| |
Collapse
|
14
|
Soo JC, Lee EG, Lee LA, Kashon ML, Harper M. Evaluation of pump pulsation in respirable size-selective sampling: Part III. Investigation of European standard methods. Ann Occup Hyg 2014; 58:1006-17. [PMID: 25053700 DOI: 10.1093/annhyg/meu047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Lee et al. (Evaluation of pump pulsation in respirable size-selective sampling: part I. Pulsation measurements. Ann Occup Hyg 2014a;58:60-73) introduced an approach to measure pump pulsation (PP) using a real-world sampling train, while the European Standards (EN) (EN 1232-1997 and EN 12919-1999) suggest measuring PP using a resistor in place of the sampler. The goal of this study is to characterize PP according to both EN methods and to determine the relationship of PP between the published method (Lee et al., 2014a) and the EN methods. Additional test parameters were investigated to determine whether the test conditions suggested by the EN methods were appropriate for measuring pulsations. Experiments were conducted using a factorial combination of personal sampling pumps (six medium- and two high-volumetric flow rate pumps), back pressures (six medium- and seven high-flow rate pumps), resistors (two types), tubing lengths between a pump and resistor (60 and 90 cm), and different flow rates (2 and 2.5 l min(-1) for the medium- and 4.4, 10, and 11.2 l min(-1) for the high-flow rate pumps). The selection of sampling pumps and the ranges of back pressure were based on measurements obtained in the previous study (Lee et al., 2014a). Among six medium-flow rate pumps, only the Gilian5000 and the Apex IS conformed to the 10% criterion specified in EN 1232-1997. Although the AirChek XR5000 exceeded the 10% limit, the average PP (10.9%) was close to the criterion. One high-flow rate pump, the Legacy (PP=8.1%), conformed to the 10% criterion in EN 12919-1999, while the Elite12 did not (PP=18.3%). Conducting supplemental tests with additional test parameters beyond those used in the two subject EN standards did not strengthen the characterization of PPs. For the selected test conditions, a linear regression model [PPEN=0.014+0.375×PPNIOSH (adjusted R2=0.871)] was developed to determine the PP relationship between the published method (Lee et al., 2014a) and the EN methods. The 25% PP criterion recommended by Lee et al. (2014a), average value derived from repetitive measurements, corresponds to 11% PPEN. The 10% pass/fail criterion in the EN Standards is not based on extensive laboratory evaluation and would unreasonably exclude at least one pump (i.e. AirChek XR5000 in this study) and, therefore, the more accurate criterion of average 11% from repetitive measurements should be substituted. This study suggests that users can measure PP using either a real-world sampling train or a resistor setup and obtain equivalent findings by applying the model herein derived. The findings of this study will be delivered to the consensus committees to be considered when those standards, including the EN 1232-1997, EN 12919-1999, and ISO 13137-2013, are revised.
Collapse
Affiliation(s)
- Jhy-Charm Soo
- 1.Exposure Assessment Branch (EAB), Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH), 1095 Willowdale Road, Morgantown, WV 26505, USA
| | - Eun Gyung Lee
- 1.Exposure Assessment Branch (EAB), Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH), 1095 Willowdale Road, Morgantown, WV 26505, USA
| | - Larry A Lee
- 1.Exposure Assessment Branch (EAB), Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH), 1095 Willowdale Road, Morgantown, WV 26505, USA
| | - Michael L Kashon
- 2.Biostatistics and Epidemiology Branch (BEB), HELD, NIOSH, 1095 Willowdale Road, Morgantown, WV 26505, USA
| | - Martin Harper
- 1.Exposure Assessment Branch (EAB), Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH), 1095 Willowdale Road, Morgantown, WV 26505, USA
| |
Collapse
|
15
|
Abstract
The objective of the present study is to quantify quartz mass in coal dust deposited on the internal cassette surface of respirable size-selective samplers. Coal dust was collected with four different respirable size-selective samplers (10 mm Dorr-Oliver nylon [Sensidyne, St. Petersburg, Fla.], SKC Aluminum [SKC Inc., Eighty Four, Pa.], BGI4L [BGI USA Inc., Waltham, Mass.], and GK2.69 cyclones [BGI USA Inc.]) with two different cassette types (polystyrene and static-dissipative polypropylene cassettes). The coal dust was aerosolized in a calm air chamber by using a fluidized bed aerosol generator without neutralization under the assumption that the procedure is similar to field sampling conditions. The mass of coal dust was measured gravimetrically and quartz mass was determined by Fourier transform infrared spectroscopy according to the National Institute for Occupational Safety and Health (NIOSH) Manual of Analytical Methods, Method 7603. The mass fractions of the total quartz sample on the internal cassette surface are significantly different between polystyrene and static-dissipative cassettes for all cyclones (p < 0.05). No consistent relationship between quartz mass on cassette internal surface and coal dust filter mass was observed. The BGI4L cyclone showed a higher (but not significantly) and the GK2.69 cyclone showed a significantly lower (p < 0.05) internal surface deposit quartz mass fraction for polystyrene cassettes compared to other cyclones. This study confirms previous observations that the interior surface deposits in polystyrene cassettes attached to cyclone pre-selectors can be a substantial part of the sample, and therefore need to be included in any analysis for accurate exposure assessment. On the other hand, the research presented here supports the position that the internal surface deposits in static-dissipative cassettes used with size-selective cyclones are negligible and that it is only necessary to analyze the filter catch.
Collapse
Affiliation(s)
- Jhy-Charm Soo
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| | - Taekhee Lee
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| | - Michael Kashon
- Biostatistics and Epidemiology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| | - Mohannad Kusti
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| | - Martin Harper
- Exposure Assessment Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia
| |
Collapse
|
16
|
Soo JC, Tsai PJ, Chen CH, Chen MR, Hsu HI, Wu TN. Influence of compressive strength and applied force in concrete on particles exposure concentrations during cutting processes. Sci Total Environ 2011; 409:3124-3128. [PMID: 21621248 DOI: 10.1016/j.scitotenv.2011.05.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2011] [Revised: 05/02/2011] [Accepted: 05/08/2011] [Indexed: 05/30/2023]
Abstract
The objective of this research was to identify the influence of applied force (AF) and the compressive strength (CS) of concrete on particle exposure concentrations during concrete cutting processes. Five cutting conditions were selected with AF varied between 9.8 and 49 N and CS varied between 2500 and 6000 psi. For each selected cutting condition, the measured total dust concentrations (C(tot)) were used to further determine the corresponding three health-related exposure concentrations of the inhalable (C(inh)), thoracic (C(thor)), and respirable fraction (C(res)). Results show that particle size distribution was consistently in a bimodal form under all selected cutting conditions. An increase in CS resulted in an increase in coarse particle generations leading to an increase in the four measured particle exposure levels. An increase in AF resulted in an increase in exposure concentrations with a higher fraction of fine particles (i.e., C(tho) and C(res)) However, for particle exposure concentrations with a higher fraction of coarse particles (i.e., C(tot) and C(inh)), an increase in AF resulted in an initial increase, followed by a decrease in concentration. Finally, the above inferences were further confirmed through the use of fixed-effect models to determine the influence of both CS and AF on the four exposure concentrations. These results provide a reference for industries to initiate appropriate control strategies to reduce the exposure levels encountered by workers.
Collapse
Affiliation(s)
- Jhy-Charm Soo
- Department of Environmental and Occupational Health, Medical College, National Cheng Kung University, 138, Sheng-Li Road, Tainan 70428, Taiwan
| | | | | | | | | | | |
Collapse
|
17
|
Soo JC, Tsai PJ, Lee SC, Lu SY, Chang CP, Liou YW, Shih TS. Establishing aerosol exposure predictive models based on vibration measurements. J Hazard Mater 2010; 178:306-311. [PMID: 20153113 DOI: 10.1016/j.jhazmat.2010.01.079] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2009] [Revised: 01/14/2010] [Accepted: 01/14/2010] [Indexed: 05/28/2023]
Abstract
This paper establishes particulate exposure predictive models based on vibration measurements under various concrete drilling conditions. The whole study was conducted in an exposure chamber using a full-scale mockup of concrete drilling simulator to simulate six drilling conditions. For each drilling condition, the vibration of the three orthogonal axes (i.e., a(x), a(y), and a(z)) was measured from the hand tool. Particulate exposure concentrations to the total suspended particulate (C(TSP)), PM(10) (C(PM10)), and PM(2.5) (C(PM2.5)) were measured at the downwind side of the drilling simulator. Empirical models for predicting C(TSP), C(PM10) and C(PM2.5) were done based on measured a(x), a(y), and a(z) using the generalized additive model. Good agreement between measured aerosol exposures and vibrations was found with R(2)>0.969. Our results also suggest that a(x) was mainly contributed by the abrasive wear. On the other hand, a(y) and a(z) were mainly contributed by both the impact wear and brittle fracture wear. The approach developed from the present study has the potential to provide a cheaper and convenient method for assessing aerosol exposures from various emission sources, particularly when conducting conventional personal aerosol samplings are not possible in the filed.
Collapse
Affiliation(s)
- Jhy-Charm Soo
- Department of Environmental and Occupational Health, Medical College, National Cheng Kung University, 138, Sheng-Li Road, Tainan 70428, Taiwan
| | | | | | | | | | | | | |
Collapse
|
18
|
Chen CH, Tsaia PJ, Lai CY, Peng YL, Soo JC, Chen CY, Shih TS. Effects of uniformities of deposition of respirable particles on filters on determining their quartz contents by using the direct on-filter X-ray diffraction (DOF XRD) method. J Hazard Mater 2010; 176:389-394. [PMID: 20006439 DOI: 10.1016/j.jhazmat.2009.11.042] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2009] [Revised: 11/05/2009] [Accepted: 11/07/2009] [Indexed: 05/28/2023]
Abstract
In this study, field samplings were conducted in three workplaces of a foundry plant, including the molding, demolding, and bead blasting, respectively. Three respirable aerosol samplers (including a 25-mm aluminum cyclone, nylon cyclone, and IOSH cyclone) were used side-by-side to collect samples from each selected workplace. For each collected sample, the uniformity of the deposition of respirable dusts on the filter was measured and its free silica content was determined by both the DOF XRD method and NIOSH 7500 XRD method (i.e., the reference method). A same trend in measured uniformities can be found in all selected workplaces: 25-mm aluminum cyclone>nylon cyclone>IOSH cyclone. Even for samples collected by the sampler with the highest uniformity (i.e., 25-mm aluminum cyclone), the use of the DOF XRD method would lead to the measured free silica concentrations 1.15-2.89 times in magnitude higher than that of the reference method. A new filter holder should be developed with the minimum uniformity comparable to that of NIOSH 7500 XRD method (=0.78) in the future. The use of conversion factors for correcting quartz concentrations obtained from the DOF XRD method based on the measured uniformities could be suitable for the foundry industry at this stage.
Collapse
Affiliation(s)
- Ching-Hwa Chen
- Department of Environmental and Occupational Health, Medical College, National Cheng Kung University, Tainan, Taiwan
| | | | | | | | | | | | | |
Collapse
|
19
|
Soo JC, Tsai PJ, Chen CH, Hsu DJ, Dai YT, Chang CP. Establishing aerosol exposure predictive models based on noise measurements--using concrete drilling as an example. J Environ Monit 2009; 11:1523-1528. [PMID: 19657538 DOI: 10.1039/b905476f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
This study used a full scale mockup of a concrete drilling simulator to simulate drilling processes in an exposure chamber. Six drilling conditions were selected with rotating speeds and drill bit sizes varied from 265 to 587 rpm and 16 to 32 mm, respectively. For each drilling condition, the emitted noise power spectrums were measured and dust exposure concentrations of the fractions of the total (C(tot)), inhalable (C(inh)), thoracic (C(tho)), and respirable (C(res)) were estimated. We find that neither the resultant dust exposure levels nor the noise levels can be explained simply by the involved drilling mechanical energy. By dividing the emitted noise power spectrums into the high and low frequency noise (i.e., W(H) and W(L)), we find that 86.3%, 85.6%, 81.5%, and 77.6% variations of C(tot), C(inh), C(tho), and C(res) could be explained by the combination of W(H) and W(L), respectively. We also find that the emissions of coarse particles and W(L) were possibly contributed by two mechanisms of the impact wear and brittle fracture wear, whereas fine particles and W(H) could be contributed by the mechanism of abrasive wear. Although the predictive models obtained from this study could not be directly used in other dust emission sources, the developed methodology would be beneficial to industries in the future for aerosol exposure assessment, particularly when conducting conventional personal aerosol samplings is not possible in the field.
Collapse
Affiliation(s)
- Jhy-Charm Soo
- Department of Environmental and Occupational Health, Medical College, National Cheng Kung University, Tainan, Taiwan
| | | | | | | | | | | |
Collapse
|
20
|
Shih TS, Lu PY, Chen CH, Soo JC, Tsai CL, Tsai PJ. Exposure profiles and source identifications for workers exposed to crystalline silica during a municipal waste incinerator relining period. J Hazard Mater 2008; 154:469-475. [PMID: 18063296 DOI: 10.1016/j.jhazmat.2007.10.047] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2007] [Revised: 10/15/2007] [Accepted: 10/15/2007] [Indexed: 05/25/2023]
Abstract
In this study, respirable crystalline silica exposures to furnace relining workers of 7 exposure groups were assessed by conducting personal respirable dust samplings. All possible pollutant sources were identified for each exposure group through field observations, and bulk samples were randomly collected from each identified pollutant source. All collected samples were analyzed for their tridymite, cristobalite, and quartz contents by using the X-ray diffraction method. Results show that quartz was the only detectable crystalline silica content. We found that the resultant respirable quartz exposure levels presented in sequence for the 7 exposure groups (sand blasting>bottom ash cleaning>wall demolishing>relining>others>grid repairing>scaffold establishing) were different from that of the corresponding respirable dust exposure levels (bottom ash cleaning>wall demolishing>sand blasting>relining>grid repairing>scaffold establishing>others). 87.3-100% of workers' respirable quartz exposures of the 7 exposure groups exceeded the TLV-TWA (0.025 mg m(-3)) indicating appropriate control strategies should be taken immediately. By comparing the fractions of quartz contained in personal respirable dust samples with that contained in all possible pollutant sources for each exposure group, this study identified main pollutant sources for each exposure group as: bottom ash cleaning and scaffold establishing: bottom ash; sand blasting: blasting sand; wall demolishing: refractory cement+wall ash; wall relining: refractory brick; grid repairing: wall ash+refractory cement; grid repairing: wall ash+refractory cement; others: blasting sand+bottom ash. Finally, effective control strategies were proposed for exposure reduction by using above information together with our field observations.
Collapse
Affiliation(s)
- Tung-Sheng Shih
- Institute of Occupational Safety and Health, Council of Labor Affairs, Executive Yuan, 99, Lane 407, Heng-Ke Road, Shijr, Taipei 217, Taiwan
| | | | | | | | | | | |
Collapse
|