Stikov N, Boudreau M, Levesque IR, Tardif CL, Barral JK, Pike GB. On the accuracy of T1 mapping: searching for common ground. Magn Reson Med 2014; 73:514-22. [PMID: 24578189 DOI: 10.1002/mrm.25135] [Citation(s) in RCA: 175] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2013] [Revised: 12/23/2013] [Accepted: 12/26/2013] [Indexed: 12/27/2022]
Abstract
PURPOSE There are many T1 mapping methods available, each of them validated in phantoms and reporting excellent agreement with literature. However, values in literature vary greatly, with T1 in white matter ranging from 690 to 1100 ms at 3 Tesla. This brings into question the accuracy of one of the most fundamental measurements in quantitative MRI. Our goal was to explain these variations and look into ways of mitigating them. THEORY AND METHODS We evaluated the three most common T1 mapping methods (inversion recovery, Look-Locker, and variable flip angle) through Bloch simulations, a white matter phantom and the brains of 10 healthy subjects (single-slice). We pooled the T1 histograms of the subjects to determine whether there is a sequence-dependent bias and whether it is reproducible across subjects. RESULTS We found good agreement between the three methods in phantoms, but poor agreement in vivo, with the white matter T1 histogram peak in healthy subjects varying by more than 30% depending on the method used. We also found that the pooled brain histograms displayed three distinct white matter peaks, with Look-Locker consistently underestimating, and variable flip angle overestimating the inversion recovery T1 values. The Bloch simulations indicated that incomplete spoiling and inaccurate B1 mapping could account for the observed differences. CONCLUSION We conclude that the three most common T1 mapping protocols produce stable T1 values in phantoms, but not in vivo. To improve the accuracy of T1 mapping, we recommend that sites perform in vivo validation of their T1 mapping method against the inversion recovery reference method, as the first step toward developing a robust calibration scheme.
Collapse
Affiliation(s)
- Nikola Stikov
- McConnel Brain Imaging Center, Montreal Neurological Institute, McGill University, Montreal, Canada
| | | | | | | | | | | |
Collapse
|
2
|
Barral JK, Overall WR, Nystrom MM, Feng X, Reeve Ingle R, Johnson KO, Hu BS, Santos JM. A novel platform for comprehensive CMR examination in a clinically feasible scan time. J Cardiovasc Magn Reson 2014. [PMCID: PMC4043422 DOI: 10.1186/1532-429x-16-s1-w10] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
|
3
|
Björk M, Ingle RR, Gudmundson E, Stoica P, Nishimura DG, Barral JK. Parameter estimation approach to banding artifact reduction in balanced steady-state free precession. Magn Reson Med 2013; 72:880-92. [PMID: 24166591 DOI: 10.1002/mrm.24986] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2013] [Revised: 08/13/2013] [Accepted: 09/02/2013] [Indexed: 11/11/2022]
Abstract
PURPOSE The balanced steady-state free precession (bSSFP) pulse sequence has shown to be of great interest due to its high signal-to-noise ratio efficiency. However, bSSFP images often suffer from banding artifacts due to off-resonance effects, which we aim to minimize in this article. METHODS We present a general and fast two-step algorithm for 1) estimating the unknowns in the bSSFP signal model from multiple phase-cycled acquisitions, and 2) reconstructing band-free images. The first step, linearization for off-resonance estimation (LORE), solves the nonlinear problem approximately by a robust linear approach. The second step applies a Gauss-Newton algorithm, initialized by LORE, to minimize the nonlinear least squares criterion. We name the full algorithm LORE-GN. RESULTS We derive the Cramér-Rao bound, a theoretical lower bound of the variance for any unbiased estimator, and show that LORE-GN is statistically efficient. Furthermore, we show that simultaneous estimation of T1 and T2 from phase-cycled bSSFP is difficult, since the Cramér-Rao bound is high at common signal-to-noise ratio. Using simulated, phantom, and in vivo data, we illustrate the band-reduction capabilities of LORE-GN compared to other techniques, such as sum-of-squares. CONCLUSION Using LORE-GN we can successfully minimize banding artifacts in bSSFP.
Collapse
Affiliation(s)
- Marcus Björk
- Department of Information Technology, Uppsala University, Uppsala, Sweden
| | | | | | | | | | | |
Collapse
|
4
|
Cho DY, Sinha SR, Gardner JM, Schaller MP, Pamnani RD, Felt SA, Barral JK, Messner AH. Effect of intratonsillar injection of steroids on the palatine tonsils of rabbits. Laryngoscope 2013; 124:2811-7. [PMID: 24114886 DOI: 10.1002/lary.24396] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Revised: 07/28/2013] [Accepted: 08/19/2013] [Indexed: 11/07/2022]
Abstract
OBJECTIVES/HYPOTHESIS Nasal steroids may significantly improve nasal obstructive symptoms with a reduction of adenoid size in children, but they do not consistently yield the same concurrent effect on enlarged palatine tonsils. Failure of nasal steroids to decrease the size of palatine tonsils is believed to be attributable to location and washout by saliva. The purpose of this study was to determine if direct application of steroid via intratonsillar injection would reduce the size of palatine tonsils in the rabbit model. STUDY DESIGN Prospective animal study. METHODS Eight rabbits (16 tonsils) were administered intratonsillar injections of fluticasone (n = 8, 1 mg/ml) or saline (n = 8, 0.1 ml) on days 0, 3, 7, 10, 14, and 17. Two rabbits (4 tonsils) received a single steroid injection to compare single versus multiple steroid injections. The rabbit's tonsil size was measured before each injection. After the fifty injections, the tonsils were harvested for histologic analysis. RESULTS A total of 16 tonsils were analyzed. After five steroid injections, the reduction (-7.7 mm(2) ± 4.27) in size was statistically significant when compared to reduction (6.12 mm(2) ± 6.57) in the saline injected group (P = 0.001). Repeated steroid injection was more potent than a single injection (-3.00 mm(2) ± 3.08) in reducing the size (P = 0.006). In histologic analysis, tonsils after repeated steroid injections were significantly smaller than saline-injected tonsils (P = 0.014), without obvious lymphoid follicles. CONCLUSION Repeated focal tonsillar injections of corticosteroids significantly reduced the size of palatine tonsils as compared to saline-injected controls. A single injection of corticosteroids appears to be effective, but not as effective, as multiple injections. LEVEL OF EVIDENCE N/A.
Collapse
Affiliation(s)
- Do-Yeon Cho
- Department of Otolaryngology-Head and Neck Surgery, Stanford University, School of Medicine, Stanford, California
| | | | | | | | | | | | | | | |
Collapse
|
5
|
Sasportas LS, Hosford DN, Sodini MA, Waters DJ, Zambricki EA, Barral JK, Graves EE, Brinton TJ, Yock PG, Le QT, Sirjani D. Cost-effectiveness landscape analysis of treatments addressing xerostomia in patients receiving head and neck radiation therapy. Oral Surg Oral Med Oral Pathol Oral Radiol 2013; 116:e37-51. [PMID: 23643579 PMCID: PMC4018820 DOI: 10.1016/j.oooo.2013.02.017] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2012] [Revised: 11/30/2012] [Accepted: 02/20/2013] [Indexed: 12/11/2022]
Abstract
Head and neck (H&N) radiation therapy (RT) can induce irreversible damage to the salivary glands thereby causing long-term xerostomia or dry mouth in 68%-85% of the patients. Not only does xerostomia significantly impair patients' quality-of-life (QOL) but it also has important medical sequelae, incurring high medical and dental costs. In this article, we review various measures to assess xerostomia and evaluate current and emerging solutions to address this condition in H&N cancer patients. These solutions typically seek to accomplish 1 of the 4 objectives: (1) to protect the salivary glands during RT, (2) to stimulate the remaining gland function, (3) to treat the symptoms of xerostomia, or (4) to regenerate the salivary glands. For each treatment, we assess its mechanisms of action, efficacy, safety, clinical utilization, and cost. We conclude that intensity-modulated radiation therapy is both the most widely used prevention approach and the most cost-effective existing solution and we highlight novel and promising techniques on the cost-effectiveness landscape.
Collapse
Affiliation(s)
- Laura S Sasportas
- Department of Bioengineering, Biodesign Innovation Program, Stanford University, Stanford, CA 94305, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Chung J, Dash R, Kee K, Barral JK, Kosuge H, Robbins RC, Nishimura D, Reijo-Pera RA, Yang PC. Theranostic effect of serial manganese-enhanced magnetic resonance imaging of human embryonic stem cell derived teratoma. Magn Reson Med 2011; 68:595-9. [PMID: 22190225 DOI: 10.1002/mrm.23262] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2011] [Accepted: 09/28/2011] [Indexed: 12/21/2022]
Abstract
Although human embryonic stem cell (hESC) hold therapeutic potential, teratoma formation has deterred clinical translation. Manganese (Mn(2+)) enters metabolically active cells through voltage-gated calcium channels and subsequently, induces T(1) shortening. We hypothesized that serial manganese-enhanced MRI would have theranostic effect to assess hESC survival, teratoma formation, and hESC-derived teratoma reduction through intracellular accumulation of Mn(2+). Firefly luciferase transduced hESCs (hESC-Lucs) were transplanted into severe combined immunodeficient mouse hindlimbs to form teratoma. The chemotherapy group was injected with MnCl(2) intraperitoneally three times a week. The control group was given MnCl(2) only prior to manganese-enhanced MRI. Longitudinal evaluation by manganese-enhanced MRI and bioluminescence imaging was performed. The chemotherapy group showed significant reduction in the teratoma volume and luciferase activity at weeks 6 and 8. Histology revealed increased proportion of dead cells and caspase 3 positive cells in the chemotherapy group. Systemic administration of MnCl(2) enabled simultaneous monitoring and elimination of hESC-derived teratoma cells by higher intracellular accumulation of Mn(2+).
Collapse
Affiliation(s)
- Jaehoon Chung
- Department of Medicine, Stanford University, Stanford, California, United States of America
| | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Chung J, Kee K, Barral JK, Dash R, Kosuge H, Wang X, Weissman I, Robbins RC, Nishimura D, Quertermous T, Reijo-Pera RA, Yang PC. In vivo molecular MRI of cell survival and teratoma formation following embryonic stem cell transplantation into the injured murine myocardium. Magn Reson Med 2011; 66:1374-81. [PMID: 21604295 DOI: 10.1002/mrm.22929] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2010] [Revised: 02/24/2011] [Accepted: 02/27/2011] [Indexed: 11/08/2022]
Abstract
Embryonic stem cells (ESCs) have shown the potential to restore cardiac function after myocardial injury. Superparamagnetic iron oxide nanoparticles (SPIO) have been widely employed to label ESCs for cellular MRI. However, nonspecific intracellular accumulation of SPIO limits long-term in vivo assessment of the transplanted cells. To overcome this limitation, a novel reporter gene (RG) has been developed to express antigens on the ESC surface. By employing SPIO-conjugated monoclonal antibody against these antigens (SPIO-MAb), the viability of transplanted ESCs can be detected in vivo. This study aims to develop a new molecular MRI method to assess in vivo ESC viability, proliferation, and teratoma formation. The RG is designed to express 2 antigens (hemagglutinin A and myc) and luciferase on the ESC surface. The two antigens serve as the molecular targets for SPIO-MAb. The human and mouse ESCs were transduced with the RG (ESC-RGs) and transplanted into the peri-infarct area using the murine myocardial injury model. In vivo MRI was performed following serial intravenous administration of SPIO-MAb. Significant hypointense signal was generated from the viable and proliferating ESCs and subsequent teratoma. This novel molecular MRI technique enabled in vivo detection of early ESC-derived teratoma formation in the injured murine myocardium.
Collapse
Affiliation(s)
- Jaehoon Chung
- Department of Medicine, Stanford University, Stanford, California, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Barral JK, Santos JM, Damrose EJ, Fischbein NJ, Nishimura DG. Real-time motion correction for high-resolution larynx imaging. Magn Reson Med 2011; 66:174-9. [PMID: 21695722 DOI: 10.1002/mrm.22773] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2010] [Revised: 11/16/2010] [Accepted: 11/24/2010] [Indexed: 11/11/2022]
Abstract
Motion--both rigid-body and nonrigid--is the main limitation to in vivo, high-resolution larynx imaging. In this work, a new real-time motion compensation algorithm is introduced. Navigator data are processed in real time to compute the displacement information, and projections are corrected using phase modulation in k-space. Upon automatic feedback, the system immediately reacquires the data most heavily corrupted by nonrigid motion, i.e., the data whose corresponding projections could not be properly corrected. This algorithm overcomes the shortcomings of the so-called diminishing variance algorithm by combining it with navigator-based rigid-body motion correction. Because rigid-body motion correction is performed first, continual bulk motion no longer impedes nor prevents the convergence of the algorithm. Phantom experiments show that the algorithm properly corrects for translations and reacquires data corrupted by nonrigid motion. Larynx imaging was performed on healthy volunteers, and substantial reduction of motion artifacts caused by bulk shift, swallowing, and coughing was achieved.
Collapse
Affiliation(s)
- Joëlle K Barral
- Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA.
| | | | | | | | | |
Collapse
|
9
|
Abstract
In this article, a robust methodology for in vivo T(1) mapping is presented. The approach combines a gold standard scanning procedure with a novel fitting procedure. Fitting complex data to a five-parameter model ensures accuracy and precision of the T(1) estimation. A reduced-dimension nonlinear least squares method is proposed. This method turns the complicated multi-parameter minimization into a straightforward one-dimensional search. As the range of possible T(1) values is known, a global grid search can be used, ensuring that a global optimal solution is found. When only magnitude data are available, the algorithm is adapted to concurrently restore polarity. The performance of the new algorithm is demonstrated in simulations and phantom experiments. The new algorithm is as accurate and precise as the conventionally used Levenberg-Marquardt algorithm but much faster. This gain in speed makes the use of the five-parameter model viable. In addition, the new algorithm does not require initialization of the search parameters. Finally, the methodology is applied in vivo to conventional brain imaging and to skin imaging. T(1) values are estimated for white matter and gray matter at 1.5 T and for dermis, hypodermis, and muscle at 1.5 T, 3 T, and 7 T.
Collapse
Affiliation(s)
- Joëlle K Barral
- Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA.
| | | | | | | | | | | |
Collapse
|
10
|
Kosuge H, Sherlock SP, Kitagawa T, Terashima M, Barral JK, Nishimura DG, Dai H, McConnell MV. FeCo/graphite nanocrystals for multi-modality imaging of experimental vascular inflammation. PLoS One 2011; 6:e14523. [PMID: 21264237 PMCID: PMC3021517 DOI: 10.1371/journal.pone.0014523] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2010] [Accepted: 12/16/2010] [Indexed: 01/23/2023] Open
Abstract
BACKGROUND FeCo/graphitic-carbon nanocrystals (FeCo/GC) are biocompatible, high-relaxivity, multi-functional nanoparticles. Macrophages represent important cellular imaging targets for assessing vascular inflammation. We evaluated FeCo/GC for vascular macrophage uptake and imaging in vivo using fluorescence and MRI. METHODS AND RESULTS Hyperlipidemic and diabetic mice underwent carotid ligation to produce a macrophage-rich vascular lesion. In situ and ex vivo fluorescence imaging were performed at 48 hours after intravenous injection of FeCo/GC conjugated to Cy5.5 (n = 8, 8 nmol of Cy5.5/mouse). Significant fluorescence signal from FeCo/GC-Cy5.5 was present in the ligated left carotid arteries, but not in the control (non-ligated) right carotid arteries or sham-operated carotid arteries (p = 0.03 for ligated vs. non-ligated). Serial in vivo 3T MRI was performed at 48 and 72 hours after intravenous FeCo/GC (n = 6, 270 µg Fe/mouse). Significant T2* signal loss from FeCo/GC was seen in ligated left carotid arteries, not in non-ligated controls (p = 0.03). Immunofluorescence staining showed colocalization of FeCo/GC and macrophages in ligated carotid arteries. CONCLUSIONS FeCo/GC accumulates in vascular macrophages in vivo, allowing fluorescence and MR imaging. This multi-functional high-relaxivity nanoparticle platform provides a promising approach for cellular imaging of vascular inflammation.
Collapse
Affiliation(s)
- Hisanori Kosuge
- Division of Cardiovascular Medicine, Stanford University, Stanford, California, United States of America
| | - Sarah P. Sherlock
- Department of Chemistry, Stanford University, Stanford, California, United States of America
| | - Toshiro Kitagawa
- Division of Cardiovascular Medicine, Stanford University, Stanford, California, United States of America
| | - Masahiro Terashima
- Division of Cardiovascular Medicine, Stanford University, Stanford, California, United States of America
| | - Joëlle K. Barral
- Electrical Engineering, Stanford University, Stanford, California, United States of America
| | - Dwight G. Nishimura
- Electrical Engineering, Stanford University, Stanford, California, United States of America
| | - Hongjie Dai
- Department of Chemistry, Stanford University, Stanford, California, United States of America
| | - Michael V. McConnell
- Division of Cardiovascular Medicine, Stanford University, Stanford, California, United States of America
- Electrical Engineering, Stanford University, Stanford, California, United States of America
- * E-mail:
| |
Collapse
|
11
|
Abstract
As a noninvasive modality, MR is attractive for in vivo skin imaging. Its unique soft tissue contrast makes it an ideal imaging modality to study the skin water content and to resolve the different skin layers. In this work, the challenges of in vivo high-resolution skin imaging are addressed. Three 3D Cartesian sequences are customized to achieve high-resolution imaging and their respective performance is evaluated. The balanced steady-state free precession (bSSFP) and gradient echo (GRE) sequences are fast but can be sensitive to off-resonance artifacts. The fast large-angle spin echo (FLASE) sequence provides a sharp depiction of the hypodermis structures but results in more specific absorption rate (SAR). The effect of increasing the field strength is assessed. As compared to 1.5 T, signal-to-noise ratio at 3 T slightly increases in the hypodermis and almost doubles in the dermis. The need for fat/water separation is acknowledged and a solution using an interleaved three-point Dixon method and an iterative reconstruction is shown to be effective. The effects of motion are analyzed and two techniques to prevent motion and correct for it are evaluated. Images with 117 x 117 x 500 microm(3) resolution are obtained in imaging times under 6 min.