1
|
Nam KM, Hendriks AD, Boer VO, Klomp DWJ, Wijnen JP, Bhogal AA. Proton metabolic mapping of the brain at 7 T using a two-dimensional free induction decay-echo-planar spectroscopic imaging readout with lipid suppression. NMR Biomed 2022; 35:e4771. [PMID: 35577344 PMCID: PMC9541868 DOI: 10.1002/nbm.4771] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 04/14/2022] [Accepted: 05/10/2022] [Indexed: 06/15/2023]
Abstract
The increased signal-to-noise ratio (SNR) and chemical shift dispersion at high magnetic fields (≥7 T) have enabled neuro-metabolic imaging at high spatial resolutions. To avoid very long acquisition times with conventional magnetic resonance spectroscopic imaging (MRSI) phase-encoding schemes, solutions such as pulse-acquire or free induction decay (FID) sequences with short repetition time and inner volume selection methods with acceleration (echo-planar spectroscopic imaging [EPSI]), have been proposed. With the inner volume selection methods, limited spatial coverage of the brain and long echo times may still impede clinical implementation. FID-MRSI sequences benefit from a short echo time and have a high SNR per time unit; however, contamination from strong extra-cranial lipid signals remains a problem that can hinder correct metabolite quantification. L2-regularization can be applied to remove lipid signals in cases with high spatial resolution and accurate prior knowledge. In this work, we developed an accelerated two-dimensional (2D) FID-MRSI sequence using an echo-planar readout and investigated the performance of lipid suppression by L2-regularization, an external crusher coil, and the combination of these two methods to compare the resulting spectral quality in three subjects. The reduction factor of lipid suppression using the crusher coil alone varies from 2 to 7 in the lipid region of the brain boundary. For the combination of the two methods, the average lipid area inside the brain was reduced by 2% to 38% compared with that of unsuppressed lipids, depending on the subject's region of interest. 2D FID-EPSI with external lipid crushing and L2-regularization provides high in-plane coverage and is suitable for investigating brain metabolite distributions at high fields.
Collapse
Affiliation(s)
- Kyung Min Nam
- Center for Image Sciences, Department of RadiologyUniversity Medical Centre UtrechtUtrecht
| | - Arjan D. Hendriks
- Center for Image Sciences, Department of RadiologyUniversity Medical Centre UtrechtUtrecht
| | - Vincent O. Boer
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and ResearchCopenhagen University Hospital HvidovreHvidovreDenmark
| | - Dennis W. J. Klomp
- Center for Image Sciences, Department of RadiologyUniversity Medical Centre UtrechtUtrecht
| | - Jannie P. Wijnen
- Center for Image Sciences, Department of RadiologyUniversity Medical Centre UtrechtUtrecht
| | - Alex A. Bhogal
- Center for Image Sciences, Department of RadiologyUniversity Medical Centre UtrechtUtrecht
| |
Collapse
|
2
|
Kumaragamage C, De Feyter HM, Brown P, McIntyre S, Nixon TW, de Graaf RA. ECLIPSE utilizing gradient-modulated offset-independent adiabaticity (GOIA) pulses for highly selective human brain proton MRSI. NMR Biomed 2021; 34:e4415. [PMID: 33001485 PMCID: PMC9472321 DOI: 10.1002/nbm.4415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Revised: 08/16/2020] [Accepted: 09/07/2020] [Indexed: 06/11/2023]
Abstract
A multitude of extracranial lipid suppression methods exist for proton MRSI acquisitions. Popular and emerging lipid suppression methods each have their inherent set of advantages and disadvantages related to the achievable level of lipid suppression, RF power deposition, insensitivity to B1+ field and lipid T1 heterogeneity, brain coverage, spatial selectivity, chemical shift displacement (CSD) errors and the reliability of spectroscopic data spanning the observed 0.9-4.7 ppm band. The utility of elliptical localization with pulsed second order fields (ECLIPSE) was previously demonstrated with a greater than 100-fold in extracranial lipid suppression and low power requirements utilizing 3 kHz bandwidth AFP pulses. Like all gradient-based localization methods, ECLIPSE is sensitive to CSD errors, resulting in a modified metabolic profile in edge-of-ROI voxels. In this work, ECLIPSE is extended with 15 kHz bandwidth second order gradient-modulated RF pulses based on the gradient offset-independent adiabaticity (GOIA) algorithm to greatly reduce CSD and improve spatial selectivity. An adiabatic double spin-echo ECLIPSE inner volume selection (TE = 45 ms) MRSI method and an ECLIPSE outer volume suppression (TE = 3.2 ms) FID-MRSI method were implemented. Both GOIA-ECLIPSE MRSI sequences provided artifact-free metabolite spectra in vivo, with a greater than 100-fold in lipid suppression and less than 2.6 mm in-plane CSD and less than 3.3 mm transition width for edge-of-ROI voxels, representing an ~5-fold improvement compared with the parent, nongradient-modulated method. Despite the 5-fold larger bandwidth, GOIA-ECLIPSE only required a 1.9-fold increase in RF power. The highly robust lipid suppression combined with low CSD and sharp ROI edge transitions make GOIA-ECLIPSE an attractive alternative to commonly employed lipid suppression methods. Furthermore, the low RF power deposition demonstrates that GOIA-ECLIPSE is very well suited for high field (≥3 T) MRSI applications.
Collapse
Affiliation(s)
- Chathura Kumaragamage
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, USA
| | - Henk M. De Feyter
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, USA
| | - Peter Brown
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, USA
| | - Scott McIntyre
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, USA
| | - Terence W. Nixon
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, USA
| | - Robin A. de Graaf
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, USA
- Department of Biomedical Engineering, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, CT, USA
| |
Collapse
|
3
|
Hassan Q, Dutta Majumdar R, Wu B, Lane D, Tabatabaei-Anraki M, Soong R, Simpson MJ, Simpson AJ. Improvements in lipid suppression for 1 H NMR-based metabolomics: Applications to solution-state and HR-MAS NMR in natural and in vivo samples. Magn Reson Chem 2018; 57:69-81. [PMID: 30520113 DOI: 10.1002/mrc.4814] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 11/28/2018] [Accepted: 11/29/2018] [Indexed: 06/09/2023]
Abstract
Proton nuclear magnetic resonance (NMR) spectra of intact biological samples often show strong contributions from lipids, which overlap with signals of interest from small metabolites. Pioneering work by Diserens et al. demonstrated that the relative differences in diffusivity and relaxation of lipids versus small metabolites could be exploited to suppress lipid signals, in high-resolution magic angle spinning (HR-MAS) NMR spectroscopy. In solution-state NMR, suspended samples can exhibit very broad water signals, which are challenging to suppress. Here, improved water suppression is incorporated into the sequence, and the Carr-Purcell-Meiboom-Gill sequence (CPMG) train is replaced with a low-power adiabatic spinlock that reduces heating and spectral artefacts seen with longer CPMG filters. The result is a robust sequence that works well in both HR-MAS as well as static solution-state samples. Applications are also extended to include in vivo organisms. For solution-state NMR, samples containing significant amount of fats such as milk and hemp hearts seeds are used to demonstrate the technique. For HR-MAS, living earthworms (Eisenia fetida) and freshwater shrimp (Hyalella azteca) are used for in vivo applications. Lipid suppression techniques are essential for non-invasive NMR-based analysis of biological samples with a high-lipid content and adds to the suite of experiments advantageous for in vivo environmental metabolomics.
Collapse
Affiliation(s)
- Qusai Hassan
- Environmental NMR Centre, Department of Physical and Environmental Sciences, University of Toronto, Toronto, Ontario, Canada
| | | | - Bing Wu
- Environmental NMR Centre, Department of Physical and Environmental Sciences, University of Toronto, Toronto, Ontario, Canada
| | - Daniel Lane
- Environmental NMR Centre, Department of Physical and Environmental Sciences, University of Toronto, Toronto, Ontario, Canada
| | - Maryam Tabatabaei-Anraki
- Environmental NMR Centre, Department of Physical and Environmental Sciences, University of Toronto, Toronto, Ontario, Canada
| | - Ronald Soong
- Environmental NMR Centre, Department of Physical and Environmental Sciences, University of Toronto, Toronto, Ontario, Canada
| | - Myrna J Simpson
- Environmental NMR Centre, Department of Physical and Environmental Sciences, University of Toronto, Toronto, Ontario, Canada
| | - Andre J Simpson
- Environmental NMR Centre, Department of Physical and Environmental Sciences, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
4
|
Tsai SY, Lin YR, Lin HY, Lin FH. Reduction of lipid contamination in MR spectroscopy imaging using signal space projection. Magn Reson Med 2018; 81:1486-1498. [PMID: 30277271 DOI: 10.1002/mrm.27496] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Revised: 06/22/2018] [Accepted: 07/25/2018] [Indexed: 12/27/2022]
Abstract
PURPOSE Lipid contamination can complicate the metabolite quantification in MR spectroscopic imaging (MRSI). In addition to various experimental methods demonstrated to be feasible for lipid suppression, the postprocessing method is beneficial in the flexibility of applications. In this study, the signal space projection (SSP) algorithm is proposed to suppress the lipid signal in the MRSI. METHODS The performance of lipid suppression using SSP and SSP combined with the Papoulis-Gerchberg (PG) algorithm (PG+SSP) is examined in 2D MRSI data and the results were compared with outer volume saturation (OVS) methods. Up to 10 lipid spatial components were extracted by SSP from lipid signals in the range of 0.8~1.5 ppm. RESULTS Our results show that most lipid signals were found in the first 4 to 5 components and that lipid signals on the spectra can be suppressed using 4 to 5 components. Metabolites concentrations were quantified using LCModel. Two regions of interest (ROIs) were manually selected on the peripheral and inner brain regions. The quantification of metabolites in terms of fitting reliability (CRLB) and spatial variations within ROIs (SpaVar) is improved using SSP. When 5 to 6 components were used in SSP and PG+SSP, the metabolite concentrations and the associated SpaVar and CRLB are at the same level as those from the OVS. CONCLUSION We have demonstrated that the SSP method can be used to suppress the lipid signals of MRSI and SSP with 5 to 6 components is suggested to have a similar suppression performance as the OVS method.
Collapse
Affiliation(s)
- Shang-Yueh Tsai
- Graduate Institute of Applied Physics, National Chengchi University, Taipei, Taiwan.,Research Center for Mind, Brain and Learning, National Chengchi University, Taipei, Taiwan
| | - Yi-Ru Lin
- Department of Electronic and Computer Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan
| | - Hsin-Yu Lin
- Department of Electronic and Computer Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan
| | - Fa-Hsuan Lin
- Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan
| |
Collapse
|
5
|
de Graaf RA, Brown PB, De Feyter HM, McIntyre S, Nixon TW. Elliptical localization with pulsed second-order fields (ECLIPSE) for robust lipid suppression in proton MRSI. NMR Biomed 2018; 31:e3949. [PMID: 29985532 PMCID: PMC6108906 DOI: 10.1002/nbm.3949] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2017] [Revised: 04/02/2018] [Accepted: 04/27/2018] [Indexed: 05/21/2023]
Abstract
Proton MRSI has great clinical potential for metabolic mapping of the healthy and pathological human brain. Unfortunately, the promise has not yet been fully achieved due to numerous technical challenges related to insufficient spectral quality caused by magnetic field inhomogeneity, insufficient RF transmit power and incomplete lipid suppression. Here a robust, novel method for lipid suppression in 1 H MRSI is presented. The method is based on 2D spatial localization of an elliptical region of interest using pulsed second-order spherical harmonic (SH) magnetic fields. A dedicated, high-amplitude second-order SH gradient setup was designed and constructed, containing coils to generate Z2, X2Y2 and XY magnetic fields. Simulations and phantom MRI results are used to demonstrate the principles of the method and illustrate the manifestation of chemical shift displacement. 1 H MRSI on human brain in vivo demonstrates high quality, robust suppression of extracranial lipids. The method allows a wide range of inner or outer volume selection or suppression and should find application in MRSI, reduced-field-of-view MRI and single-volume MRS.
Collapse
Affiliation(s)
- Robin A. de Graaf
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, Connecticut, USA
- Department of Biomedical Engineering, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Peter B. Brown
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Henk M. De Feyter
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Scott McIntyre
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Terence W. Nixon
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, Connecticut, USA
| |
Collapse
|
6
|
Bhattacharya I, Jacob M. Compartmentalized low-rank recovery for high-resolution lipid unsuppressed MRSI. Magn Reson Med 2016; 78:1267-1280. [PMID: 27851875 DOI: 10.1002/mrm.26537] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2015] [Revised: 09/16/2016] [Accepted: 10/10/2016] [Indexed: 11/10/2022]
Abstract
PURPOSE To introduce a novel algorithm for the recovery of high-resolution magnetic resonance spectroscopic imaging (MRSI) data with minimal lipid leakage artifacts, from dual-density spiral acquisition. METHODS The reconstruction of MRSI data from dual-density spiral data is formulated as a compartmental low-rank recovery problem. The MRSI dataset is modeled as the sum of metabolite and lipid signals, each of which is support limited to the brain and extracranial regions, respectively, in addition to being orthogonal to each other. The reconstruction problem is formulated as an optimization problem, which is solved using iterative reweighted nuclear norm minimization. RESULTS The comparisons of the scheme against dual-resolution reconstruction algorithm on numerical phantom and in vivo datasets demonstrate the ability of the scheme to provide higher spatial resolution and lower lipid leakage artifacts. The experiments demonstrate the ability of the scheme to recover the metabolite maps, from lipid unsuppressed datasets with echo time (TE) = 55 ms. CONCLUSION The proposed reconstruction method and data acquisition strategy provide an efficient way to achieve high-resolution metabolite maps without lipid suppression. This algorithm would be beneficial for fast metabolic mapping and extension to multislice acquisitions. Magn Reson Med 78:1267-1280, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Ipshita Bhattacharya
- Department of Electrical and Computer Engineering, The University of Iowa, Iowa City, Iowa, USA
| | - Mathews Jacob
- Department of Electrical and Computer Engineering, The University of Iowa, Iowa City, Iowa, USA
| |
Collapse
|
7
|
Esmaeili M, Bathen TF, Rosen BR, Andronesi OC. Three-dimensional MR spectroscopic imaging using adiabatic spin echo and hypergeometric dual-band suppression for metabolic mapping over the entire brain. Magn Reson Med 2016; 77:490-497. [PMID: 26840906 DOI: 10.1002/mrm.26115] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2015] [Revised: 12/14/2015] [Accepted: 12/16/2015] [Indexed: 11/12/2022]
Abstract
PURPOSE Large lipid and water signals in MR spectroscopic imaging (MRSI) complicate brain metabolite quantification. In this study, we combined adiabatic hypergeometric dual-band (HGDB) lipid and water suppression with gradient offset independent adiabatic (GOIA) spin echo to improve three-dimensional (3D) MRSI of the entire brain. METHODS 3D MRSI was acquired at 3T with a 32-channel coil. HGDB pulses were used before excitation and during echo time. A brain slab was selected with GOIA-W(16,4) pulses, weighted phase encoded stack of spirals, and real-time motion/shim correction. HGDB alone or in combination with OVS and MEGA (MEscher-GArwood) was compared with OVS only and no suppression. RESULTS The combined HGDB pulses suppressed lipids to 2%-3% of their full unsuppressed signal. The HGDB lipid suppression was on average 5 times better than OVS suppression. HGDB+MEGA provided 30% more suppression compared with a previously described HGDB+OVS scheme. The number of voxels with good metabolic fits was significantly larger in the HGDB data (91%-94%) compared with the OVS data (59%-80%). CONCLUSION HGDB pulses provided efficient lipid and water suppression for full brain 3D MRSI. The HGDB suppression is superior to traditional OVS, and it can be combined with adiabatic spin echo to provide a sequence that is robust to B1 inhomogeneity. Magn Reson Med 77:490-497, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Morteza Esmaeili
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.,Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
| | - Tone F Bathen
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
| | - Bruce R Rosen
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Ovidiu C Andronesi
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
8
|
Hangel G, Strasser B, Považan M, Gruber S, Chmelík M, Gajdošík M, Trattnig S, Bogner W. Lipid suppression via double inversion recovery with symmetric frequency sweep for robust 2D-GRAPPA-accelerated MRSI of the brain at 7 T. NMR Biomed 2015; 28:1413-25. [PMID: 26370781 PMCID: PMC4973691 DOI: 10.1002/nbm.3386] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2015] [Revised: 07/20/2015] [Accepted: 07/29/2015] [Indexed: 05/06/2023]
Abstract
This work presents a new approach for high-resolution MRSI of the brain at 7 T in clinically feasible measurement times. Two major problems of MRSI are the long scan times for large matrix sizes and the possible spectral contamination by the transcranial lipid signal. We propose a combination of free induction decay (FID)-MRSI with a short acquisition delay and acceleration via in-plane two-dimensional generalised autocalibrating partially parallel acquisition (2D-GRAPPA) with adiabatic double inversion recovery (IR)-based lipid suppression to allow robust high-resolution MRSI. We performed Bloch simulations to evaluate the magnetisation pathways of lipids and metabolites, and compared the results with phantom measurements. Acceleration factors in the range 2-25 were tested in a phantom. Five volunteers were scanned to verify the value of our MRSI method in vivo. GRAPPA artefacts that cause fold-in of transcranial lipids were suppressed via double IR, with a non-selective symmetric frequency sweep. The use of long, low-power inversion pulses (100 ms) reduced specific absorption rate requirements. The symmetric frequency sweep over both pulses provided good lipid suppression (>90%), in addition to a reduced loss in metabolite signal-to-noise ratio (SNR), compared with conventional IR suppression (52-70%). The metabolic mapping over the whole brain slice was not limited to a rectangular region of interest. 2D-GRAPPA provided acceleration up to a factor of nine for in vivo FID-MRSI without a substantial increase in g-factors (<1.1). A 64 × 64 matrix can be acquired with a common repetition time of ~1.3 s in only 8 min without lipid artefacts caused by acceleration. Overall, we present a fast and robust MRSI method, using combined double IR fat suppression and 2D-GRAPPA acceleration, which may be used in (pre)clinical studies of the brain at 7 T.
Collapse
Affiliation(s)
- Gilbert Hangel
- MR Centre of Excellence (MRCE), Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Bernhard Strasser
- MR Centre of Excellence (MRCE), Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Michal Považan
- MR Centre of Excellence (MRCE), Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Stephan Gruber
- MR Centre of Excellence (MRCE), Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Marek Chmelík
- MR Centre of Excellence (MRCE), Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Martin Gajdošík
- MR Centre of Excellence (MRCE), Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Siegfried Trattnig
- MR Centre of Excellence (MRCE), Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Medical University of Vienna, Vienna, Austria
| | - Wolfgang Bogner
- MR Centre of Excellence (MRCE), Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
9
|
Bilgic B, Chatnuntawech I, Fan AP, Setsompop K, Cauley SF, Wald LL, Adalsteinsson E. Fast image reconstruction with L2-regularization. J Magn Reson Imaging 2014; 40:181-91. [PMID: 24395184 PMCID: PMC4106040 DOI: 10.1002/jmri.24365] [Citation(s) in RCA: 87] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2013] [Accepted: 07/16/2013] [Indexed: 11/07/2022] Open
Abstract
PURPOSE We introduce L2-regularized reconstruction algorithms with closed-form solutions that achieve dramatic computational speed-up relative to state of the art L1- and L2-based iterative algorithms while maintaining similar image quality for various applications in MRI reconstruction. MATERIALS AND METHODS We compare fast L2-based methods to state of the art algorithms employing iterative L1- and L2-regularization in numerical phantom and in vivo data in three applications; (i) Fast Quantitative Susceptibility Mapping (QSM), (ii) Lipid artifact suppression in Magnetic Resonance Spectroscopic Imaging (MRSI), and (iii) Diffusion Spectrum Imaging (DSI). In all cases, proposed L2-based methods are compared with the state of the art algorithms, and two to three orders of magnitude speed up is demonstrated with similar reconstruction quality. RESULTS The closed-form solution developed for regularized QSM allows processing of a three-dimensional volume under 5 s, the proposed lipid suppression algorithm takes under 1 s to reconstruct single-slice MRSI data, while the PCA based DSI algorithm estimates diffusion propagators from undersampled q-space for a single slice under 30 s, all running in Matlab using a standard workstation. CONCLUSION For the applications considered herein, closed-form L2-regularization can be a faster alternative to its iterative counterpart or L1-based iterative algorithms, without compromising image quality.
Collapse
Affiliation(s)
- Berkin Bilgic
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
- A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
| | - Itthi Chatnuntawech
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Audrey P. Fan
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Kawin Setsompop
- A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Stephen F. Cauley
- A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
| | - Lawrence L. Wald
- A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
- Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Elfar Adalsteinsson
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
- Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| |
Collapse
|
10
|
Boer VO, van de Lindt T, Luijten PR, Klomp DWJ. Lipid suppression for brain MRI and MRSI by means of a dedicated crusher coil. Magn Reson Med 2014; 73:2062-8. [PMID: 24947343 DOI: 10.1002/mrm.25331] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2013] [Revised: 05/07/2014] [Accepted: 06/02/2014] [Indexed: 01/13/2023]
Abstract
PURPOSE Lipid suppression in MR brain imaging and spectroscopy has been a long-standing problem for which various techniques have been developed. Most methods are based on inversion recovery or spatially or spectrally selective excitation of the lipid signal followed by dephasing. All techniques require additional RF pulses, gradient crushers and delays, which increase the duration and complexity of sequences. In addition, the lipid signal is poorly shimmed, and is composed of different resonance frequencies that have different relaxation properties. METHODS In this work, a novel approach for suppression of extra cranial lipids is presented, by means of an outer volume crusher coil. It is based on the principle of surface spoiling gradients, which generate a very local and inhomogeneous magnetic field in the outer layer of the head, and thereby destroys the phase coherence of the extra cranial signals. RESULTS Dephasing of the signal can be incorporated in almost any sequence because it requires only a short pulse of the coil, and does not require additional RF pulses or delays. Examples of lipid suppression are shown in both gradient echo imaging and spectroscopic imaging. CONCLUSION Outer volume crushing allows for simple fat suppression and boosts scanning efficiency, which is particularly beneficial at ultra-high field strengths.
Collapse
Affiliation(s)
- Vincent O Boer
- Department of Radiology, University Medical Center Utrecht, The Netherlands
| | - Tessa van de Lindt
- Department of Radiology, University Medical Center Utrecht, The Netherlands
| | - Peter R Luijten
- Department of Radiology, University Medical Center Utrecht, The Netherlands
| | - Dennis W J Klomp
- Department of Radiology, University Medical Center Utrecht, The Netherlands
| |
Collapse
|
11
|
Boer VO, Luttje MP, Luijten PR, Klomp DWJ. Requirements for static and dynamic higher order B0 shimming of the human breast at 7 T. NMR Biomed 2014; 27:625-631. [PMID: 24615920 DOI: 10.1002/nbm.3096] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2013] [Revised: 01/09/2014] [Accepted: 01/23/2014] [Indexed: 06/03/2023]
Abstract
The increased magnetic susceptibility effects at higher magnetic fields increase the demands for shimming of the B0 field for in vivo MRI and MRS. Both static and dynamic techniques have been developed to compensate for susceptibility-induced field inhomogeneities. In this study, we investigate the impact of and need for both static and dynamic higher order B0 shimming of magnetic field homogeneities in clinical breast MRI at 7 T. Both global and local field variations at lipid-tissue interfaces were observed in the magnetic field using TE-optimized B0 mapping at 7 T. With static B0 shimming, a field homogeneity of 39 ± 11 Hz (n = 48) was reached in a single breast using second-order shimming. Further compensation of the residual local field inhomogeneities caused by lipid-tissue interfaces does not seem to be feasible with shallow spherical harmonic fields. For bilateral shimming, the shimming quality was significantly less at 62 ± 15 Hz (n = 22) over both breasts, even after (simulated) fourth-order shimming. In addition, a substantial time-dependent field instability of 30 Hz peak to peak, with significant higher order field contributions, was observed during regular breathing. In conclusion, TE-optimized B0 field mapping reveals substantial field variations in the lipid-rich environment of the human breast, in both space and time. The static field variations could be partially minimized by third-order B0 shimming, providing sufficient lipid suppression. However, in order to fully benefit from the increased spectral dispersion at high fields, the significant magnetic field variations during breathing need to be considered.
Collapse
Affiliation(s)
- Vincent O Boer
- Department of Radiology, University Medical Center Utrecht, the Netherlands
| | | | | | | |
Collapse
|
12
|
Lu J, Zhou J, Cai C, Cai S, Chen Z. Observation of true and pseudo NOE signals using CEST-MRI and CEST-MRS sequences with and without lipid suppression. Magn Reson Med 2014; 73:1615-22. [PMID: 24803172 DOI: 10.1002/mrm.25277] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2014] [Revised: 04/09/2014] [Accepted: 04/11/2014] [Indexed: 11/08/2022]
Abstract
PURPOSE To investigate the characteristics of nuclear Overhauser enhancement (NOE) imaging signals in the brain at 7T. METHODS Fresh hen eggs, as well as six healthy, and six C6 glioma-bearing Wistar rats were scanned using chemical exchange saturation transfer-magnetic resonance imaging (CEST-MRI) and chemical exchange saturation transfer-magnetic resonance spectroscopy (CEST-MRS) sequences (saturation duration 3 s, power 1.47 µT) with and without lipid suppression. CEST data were acquired over an offset range of -6 to +6 ppm relative to the water resonance in 0.5 ppm steps. RESULTS The water signals were not disrupted by other protons during the CEST-MRS sequences, and true NOE signals could be observed. Using the CEST-MRI sequence without lipid suppression, pseudo NOE imaging signals were observed in the lipid-containing regions (egg yolk, scalp, and even white matter). These pseudo NOE signals were almost (but incompletely) removed with the lipid suppression. Egg yolk results indicated the presence of the NOE to olefinic protons overlapping with the water signal. In vivo experiments showed that the amide proton transfer signal was larger in the tumor, whereas the NOE signal was larger in the normal white matter. CONCLUSIONS True NOE signals can be detected using MRS sequences, and considerable pseudo NOE imaging signals may be observed using MRI sequences.
Collapse
Affiliation(s)
- Jianhua Lu
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | | | | | | | | |
Collapse
|