1
|
EFFECTS OF SUPPLEMENTS CONTAINING CURCUMIN, OMEGA FATTY ACIDS, GAMMA LINOLENIC ACID, VITAMIN E, VITAMIN D, HYDROXYTYROSOL, AND ASTAXANTHIN ON CARDIOVASCULAR HEALTH: A RANDOMIZED, DOUBLE-BLIND, PLACEBO-CONTROLLED CLINICAL TRIAL. Am J Prev Cardiol 2023. [DOI: 10.1016/j.ajpc.2022.100401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023] Open
|
2
|
Coronary computed tomography angiography evaluation of plaque morphology and its relationship to HDL and total cholesterol to HDL ratio. J Clin Lipidol 2022; 16:715-724. [DOI: 10.1016/j.jacl.2022.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Revised: 06/05/2022] [Accepted: 06/13/2022] [Indexed: 11/25/2022]
|
3
|
Radiation Doses in Patients Undergoing Computed Tomographic Coronary Artery Calcium Evaluation With a 64-Slice Scanner Versus a 256-Slice Scanner. Tex Heart Inst J 2022; 49:478371. [PMID: 35244722 DOI: 10.14503/thij-18-6793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Computed tomographic coronary artery calcium scanning enables cardiovascular risk stratification; however, exposing patients to high radiation levels is an ongoing concern. New-generation computed tomographic systems use lower radiation doses than older systems do. To quantify comparative doses of radiation exposure, we prospectively acquired images from 220 patients with use of a 64-slice GE LightSpeed VCT scanner (control group, n=110) and a 256-slice GE Revolution scanner (study group, n=110). The groups were matched for age, sex, and body mass index; statistical analysis included t tests and linear regression. The mean dose-length product was 21% lower in the study group than in the control group (60.2 ± 27 vs 75.9 ± 22.6 mGy·cm; P <0.001) and also in each body mass index subgroup. Similarly, the mean effective radiation dose was 21% lower in the study group (0.84 ± 0.38 vs 1.06 ± 0.32 mSv) and lower in each weight subgroup. After adjustment for sex, women in the study group had a lower dose-length product (50.4 ± 23.4 vs 64.7 ± 27.6 mGy·cm) than men did and received a lower effective dose (0.7 ± 0.32 vs 0.9 ± 0.38 mSv) (P=0.009). As body mass index and waist circumference increased, so did doses for both scanners. Our study group was exposed to radiation doses lower than the previously determined standard of 1 mSv, even after adjustment for body mass index and waist circumference. In 256-slice scanning for coronary artery calcium, radiation doses are now similar to those in lung cancer screening and mammography.
Collapse
|
4
|
ASSOCIATION BETWEEN CORONARY ARTERY CALCIUM SCORE, TOTAL PLAQUE BURDEN, AND NON-CALCIFIED PLAQUE: A POST HOC ANALYSIS OF SERIAL CORONARY COMPUTED TOMOGRAPHY ANGIOGRAPHY (CCTA) STUDIES. J Am Coll Cardiol 2022. [DOI: 10.1016/s0735-1097(22)02229-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
5
|
Serum Thyrotropin Elevation and Coronary Artery Calcification in Hemodialysis Patients. Cardiorenal Med 2022; 12:106-116. [PMID: 35551382 PMCID: PMC9452456 DOI: 10.1159/000525037] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2021] [Accepted: 05/03/2022] [Indexed: 01/31/2023] Open
Abstract
INTRODUCTION Hypothyroidism is highly prevalent in end-stage kidney disease patients, and emerging data show that lower circulating thyroid hormone levels lead to downregulation of vascular calcification inhibitors and coronary artery calcification (CAC) in this population. To date, no studies have examined the association of serum thyrotropin (TSH), the most sensitive and specific single biochemical metric of thyroid function, with CAC risk in hemodialysis patients. METHODS In secondary analyses of patients from the Anti-Inflammatory and Anti-Oxidative Nutrition in Hypoalbuminemic Dialysis Patients trial, we examined serum TSH levels and CAC risk assessed by cardiac computed tomography scans collected within a 90-day period. We evaluated the relationship between serum TSH with CAC Volume (VS) and Agatston score (AS) (defined as >100 mm3 and >100 Houndsfield Units, respectively) using multivariable logistic regression. RESULTS Among 104 patients who met eligibility criteria, higher TSH levels in the highest tertile were associated with moderately elevated CAC VS and AS in case-mix-adjusted analyses (ref: lowest tertile): adjusted ORs (95% CIs) 4.26 (1.18, 15.40) and 5.53 (1.44, 21.30), respectively. TSH levels >3.0 mIU/L (ref: ≤3.0 mIU/L) were also associated with moderately elevated CAC VS and AS. In secondary analyses, point estimates of incrementally lower direct free thyroxine levels trended toward elevated CAC VS and AS, although associations did not achieve statistical significance. CONCLUSIONS In hemodialysis patients, higher serum TSH was associated with elevated CAC VS and AS. Further studies are needed to determine if thyroid hormone supplementation can attenuate CAC burden in this population.
Collapse
|
6
|
Elevated serum thyrotropin levels and endothelial dysfunction in a prospective hemodialysis cohort. Hemodial Int 2022; 26:57-65. [PMID: 34231302 PMCID: PMC10753993 DOI: 10.1111/hdi.12964] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 06/13/2021] [Accepted: 06/19/2021] [Indexed: 01/07/2023]
Abstract
INTRODUCTION Thyroid dysfunction is a highly prevalent yet under-recognized complication in hemodialysis patients. In the general population, hypothyroidism has been associated with endothelial dysfunction due to impaired vasodilator synthesis and activity. Little is known about the association of serum thyrotropin (TSH), the most sensitive and specific single biochemical metric of thyroid function, with endothelial function in hemodialysis patients. METHODS In a secondary analysis of 99 patients from the Anti-inflammatory and anti-oxidative nutrition in hypoalbuminemic dialysis patients (AIONID) trial, we examined measurements of serum TSH and endothelial function ascertained by fingertip digital thermal monitoring (DTM), a novel method used to measure micro-vascular reactivity, collected within a 90-day period. DTM was used to measure changes in fingertip temperature during and after an ischemic stimulus (blood pressure cuff occlusion) as an indicator of changes in blood flow, and two DTM indices were assessed, namely adjusted (a) Temperature Rebound (TR), defined as the maximum temperature rebound post-cuff deflation, and adjusted (b) Area Under the Temperature Curve (TMP-AUC), defined as area under the curve between the maximum and minimum temperatures. We examined the relationship between serum TSH with impaired TR (separately) and TMP-AUC (both defined as less than the median level of observed values) using multivariable logistic regression. FINDINGS In unadjusted and case-mix analyses, higher serum TSH levels (defined as the three highest quartiles) were associated with lower (worse) TR (ref: lowest TSH quartile): ORs (95% CI) 2.64 (1.01-6.88) and 2.85 (1.08-7.57), respectively. In unadjusted and case-mix analyses, higher TSH levels were associated with lower (worse) TMP-AUC: ORs (95% CI) 2.64 (1.01-6.88) and 2.79 (1.06-7.38), respectively. DISCUSSION In HD patients, higher serum TSH levels were associated with worse micro-vascular reactivity measured by DTM. Further studies are needed to determine if thyroid hormone supplementation improves endothelial function in hemodialysis patients with lower levels of thyroid function.
Collapse
|
7
|
Coronary CT Angiography Predicts Major Adverse Events In Dialysis Dependent End-stage Renal Disease Patients. J Cardiovasc Comput Tomogr 2021. [DOI: 10.1016/j.jcct.2021.06.282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
8
|
COVID-19 IgG/IgM antibody testing in Los Angeles County, California. Eur J Clin Microbiol Infect Dis 2021; 40:457-459. [PMID: 33241444 PMCID: PMC7688294 DOI: 10.1007/s10096-020-04111-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Accepted: 11/20/2020] [Indexed: 11/26/2022]
Abstract
Evidence suggests that asymptomatic and mild SARS-CoV-2 infections comprise > 95% of all cases. Developing a test that indicates past infection and possible immunity against the virus is important. We administered 244 antibody tests to three groups of high-risk population. The test consisted of an IgG component and an IgM component. The overall IgM/IgG positivity for patients with none, mild, moderate, and severe symptoms were 21.1%, 21.8%, 14.2%, and 26.9%, respectively. Those with moderate or severe symptoms were no more or less likely to have positive antibody tests than those with no or mild symptoms.
Collapse
|
9
|
The relationship between coronary artery calcium density and optical coherence tomography-derived plaque characteristics. Atherosclerosis 2020; 311:30-36. [PMID: 32919282 DOI: 10.1016/j.atherosclerosis.2020.08.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 07/14/2020] [Accepted: 08/25/2020] [Indexed: 01/07/2023]
Abstract
BACKGROUND AND AIMS Although coronary artery calcium (CAC) density has been associated with plaque stability, pathological evidence is lacking. We investigated the relationship between coronary computed tomography (CCT)-derived CAC density and multiple calcified and high-risk plaque (HRP) characteristics using optical coherence tomography (OCT). METHODS We analyzed 83 plaques from 33 stable angina patients who underwent both CCT and OCT. CAC density was measured at calcium plaques with ≥90 Hounsfield units (HU) and ≥130 HU using custom CT software. The correlation between median CAC density and OCT-derived calcium size (thickness and area) was assessed. To investigate whether median CAC densities measured at the 90 HU threshold were associated with plaque vulnerability, OCT-derived plaque characteristics and HRP characteristics were compared between the low (90-129 HU), intermediate (130-199 HU) and high (≥200 HU) CAC HU groups. RESULTS Median CAC densities at 130 HU were moderately associated with calcium thickness (R = 0.573, p < 0.001) and area (R = 0.560, p < 0.001). Similar results were observed at 90 HU (thickness, R = 0.615, p < 0.001; area, R = 0.612, p < 0.001). Among groups with low, intermediate and high HU levels, calcium thickness (0.42 ± 0.14 mm, 0.60 ± 0.17 mm and 0.77 ± 0.19 mm, respectively; p < 0.001) and area (0.55 ± 0.29 mm2, 1.20 ± 0.58 mm2 and 1.78 ± 0.87 mm2, respectively; p < 0.001) were significantly greater in the high HU group. HRP characteristics, however, did not differ among the three groups. CONCLUSIONS OCT-derived calcium size, but not HRP characteristics, were associated with CAC density, suggesting that CAC density is driven mainly by calcified plaque size but not local plaque vulnerability.
Collapse
|
10
|
Atherosclerosis As A Systemic Disease: The Correlation Of Carotid And Coronary Artery Plaques. J Cardiovasc Comput Tomogr 2020. [DOI: 10.1016/j.jcct.2020.06.147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
11
|
Association of high-density lipoprotein levels with baseline coronary plaque volumes by coronary CTA in the EVAPORATE trial. Atherosclerosis 2020; 305:34-41. [PMID: 32615321 DOI: 10.1016/j.atherosclerosis.2020.05.014] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 04/24/2020] [Accepted: 05/20/2020] [Indexed: 01/18/2023]
Abstract
BACKGROUND AND AIMS Dyslipidemia with elevated triglycerides (TGL) and low high-density lipoprotein cholesterol (HDL-C) predicts residual cardiovascular risk, despite goal LDL-C levels and optimal statin therapy. Coronary plaque characterization by CCTA can provide mechanistic understanding of coronary artery disease and associated prognosis. The role of HDL-C in the pathogenesis of atherosclerosis is not well understood in statin-treated patients with elevated TGL. We sought to examine the association of HDL-C levels with baseline coronary plaque volumes, namely total plaque (TP) and total non-calcified plaque (TNCP) volumes by CCTA in participants enrolled in the EVAPORATE trial. METHODS We analyzed 80 participants who were enrolled in the trial. Linear regression analysis as a univariate and multivariate model adjusted for significant cardiovascular risk factors was performed to evaluate independent association of HDL-C and baseline coronary plaque volumes. In an exploratory analysis, stratified by sex, we compared the association of serum HDL-C levels with baseline coronary plaque volumes in males and females. RESULTS Mean (SD) age of participants (n = 80) was 57.1 (8.6) years and 43% were male. Median (Inter Quartile Range/IQR) log-TNCP volume was 83.0 (0.1-7.3) mm3 and median (IQR) log-TP volume was 144.8 (0.1-7.1) mm3. After adjustment for relevant clinical covariates including age, gender, BMI, hypertension, diabetes, past smoking and baseline TGL levels, increasing levels of HDL-C remain independently associated with lower baseline log-TNCP volumes (β: 0.043 ± 0.021, p = 0.042) and baseline log-TP volumes (β: 0.046 ± 0.022, p = 0.035) on CCTA. On stratifying by sex in a multivariable regression analysis, HDL-C levels were inversely associated with baseline log-TNCP volumes (β: 0.066 ± 0.026, p = 0.018) and log-TP volumes (β: 0.077 ± 0.025, p = 0.004) in females, but not in males (log-TNCP volumes β: 0.038 ± 0.034, p = 0.282) and log-TP volumes (β: -0.033 ± 0.036, p = 0.364). CONCLUSIONS In a cohort of statin treated patients with known atherosclerosis and residually elevated TGL, there was a significant inverse relationship between HDL-C levels and baseline coronary plaque, TP and TNCP volumes on CCTA. Our findings provide more detailed mechanistic evidence regarding the protective role of HDL-C in coronary atherosclerosis in a high-risk cohort. Further investigation to evaluate the interaction of HDL-C levels and coronary plaque volumes on differential CVD risk in statin-treated patients with elevated TGL levels is warranted.
Collapse
|
12
|
A novel density-volume calcium score by non-contrast CT predicts coronary plaque burden on coronary CT angiography: Results from the MACS (Multicenter AIDS cohort study). J Cardiovasc Comput Tomogr 2020; 14:266-271. [PMID: 31564631 PMCID: PMC7089811 DOI: 10.1016/j.jcct.2019.09.016] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Revised: 11/30/2018] [Accepted: 09/23/2019] [Indexed: 01/07/2023]
Abstract
BACKGROUND The purpose of this study is to determine if a new score calculated with coronary artery calcium (CAC) density and volume is associated with total coronary artery plaque burden and composition on coronary CT angiography (CCTA) compared to the Agatston score (AS). METHODS We identified 347 men enrolled in the Multicenter AIDS cohort study who underwent contrast and non-contrast CCTs, and had CAC>0. CAC densities (mean Hounsfield Units [HU]) per plaque) and volumes on non-contrast CCT were measured. A Density-Volume Calcium score was calculated by multiplying the plaque volume by a factor based on the mean HU of the plaque (4, 3, 2 and 1 for 130-199, 200-299, 300-399, and ≥400HU). Total Density-Volume Calcium score was determined by the sum of these individual scores. The semi-quantitative partially calcified and total plaque scores (PCPS and TPS) on CCTA were calculated. The associations between Density-Volume Calcium score, PCPS and TPS were examined. RESULTS Overall, 2879 CAC plaques were assessed. Multivariable linear regression models demonstrated a stronger association between the log Density-Volume Calcium score and both the PCPS (β 0.99, 95%CI 0.80-1.19) and TPS (β 2.15, 95%CI 1.88-2.42) compared to the log of AS (PCPS: β 0.77, 95%CI 0.61-0.94; TPS: β 1.70, 95%CI 1.48-1.94). Similar results were observed for numbers of PC or TP segments. CONCLUSION The new CAC score weighted towards lower density demonstrated improved correlation with semi-quantitative PC and TP burden on CCTA compared to the traditional AS, which suggests it has utility as an alternative measure of atherosclerotic burden.
Collapse
|
13
|
Lower Radiation Dosing in Cardiac CT Angiography: The CONVERGE Registry. J Nucl Med Technol 2020; 48:58-62. [DOI: 10.2967/jnmt.119.229500] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Accepted: 08/05/2019] [Indexed: 11/16/2022] Open
|
14
|
ASSOCIATION OF INFLAMMATORY MARKERS WITH BASELINE CORONARY PLAQUE VOLUMES BY CORONARY COMPUTED TOMOGRAPHY ANGIOGRAPHY (CCTA) FROM EVAPORATE (EFFECT OF VASCEPA ON IMPROVING CORONARY ATHEROSCLEROSIS IN PEOPLE WITH HIGH TRIGLYCERIDES TAKING STATIN THERAPY) TRIAL. J Am Coll Cardiol 2020. [DOI: 10.1016/s0735-1097(20)32347-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
15
|
CORONARY ARTERY CALCIUM (CAC) AND GENOMIC RISK SCORES (GRS): ANALYTICAL APPROACH OF PILOT STUDY BASED CARDIOVASCULAR RISK. J Am Coll Cardiol 2020. [DOI: 10.1016/s0735-1097(20)32567-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
16
|
Lower Radiation Dosing in Cardiac Computed Tomographic Angiography: the CONVERGE Registry. J Nucl Med Technol 2019:jnumed.119.229500. [PMID: 31604891 DOI: 10.2967/jnumed.119.229500] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Accepted: 08/05/2019] [Indexed: 11/16/2022] Open
Abstract
Intro: Coronary artery disease is the leading cause for morbidity and mortality. Tools have been developed to accurately diagnose and evaluate coronary artery disease. Coronary computed tomographic angiography (CCTA) scans provide detailed imaging along with analysis to in order to deliver precise analysis and prognostic information. We sought to evaluate the radiation doses of the 256 detector CT scanner to a 64 slice scanner across a similar profile of patients. Methods: Consecutive patients were screened, enrolled, and consented for the Converge Registry study, in accordance with the Institutional Review Board (IRB) approved protocol. 110 patients underwent CCTA using the GE Revolution 256 detector CT scanner. We matched patients by age, gender and body mass index (BMI) who underwent 64 slice CT scanning. Results: We compared 110 patients in each group. We found that mean dose length product (DLP, presented also in the tables below in millisieverts (mSv)) was significantly lower in the Revolution 256 detector group compared to the 64 slice control group (p<0.05). The radiation dose was reduced 32% with use of Revolution 256 detector scanner for BMI between 18.5 and 24.9 (DLP = 111.2 vs 76.1; 1.56 vs 1.07 mSv; p<0.05). For each BMI subgroup, there was a significant decrease in dose. Regression analysis found that with the increase in BMI both scanners experienced a significant increase in DLP. Conclusion: We are able to demonstrate that the 256 slice CT scanner is able to provide CCTA scans at significantly lower radiation doses compared to the 64 row scanner at different BMI groups, with all other variables accounted for. Lower radiation exposures along with lower contrast requirements can provide quality imaging with high diagnostic accuracy and less risk to the patient.
Collapse
|
17
|
Apixaban versus warfarin in evaluation of progression of atherosclerotic and calcified plaques (prospective randomized trial). Am Heart J 2019; 212:129-133. [PMID: 31002997 DOI: 10.1016/j.ahj.2019.02.014] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2018] [Accepted: 02/23/2019] [Indexed: 01/23/2023]
Abstract
Warfarin has been showed to increase vascular calcification. Apixaban, a direct factor Xa inhibitor, has no interaction with vitamin K and its effect on coronary plaques is unknown. We randomized and compared warfarin and apixaban on progression of coronary atherosclerotic plaques measured by coronary computed tomographic angiography in 66 subjects with non-valvular atrial fibrillation over the period of one-year follow up. There was significant higher total, calcified and low attenuation plaque volume in the group randomized to warfarin as compared to apixaban (all P < .05). Greater volume of total (β2 = 28.54; P = .03), low attenuation plaque (β2 = 3.58; P = .02) and calcified (β2 = 14.10; P = .005) plaque progression was observed in the VKA_group.
Collapse
|
18
|
Non-contrast cardiac CT-based quantitative evaluation of epicardial and intra-thoracic fat in healthy, recently menopausal women: Reproducibility data from the Kronos Early Estrogen Prevention Study. J Cardiovasc Comput Tomogr 2019; 14:55-59. [PMID: 31078511 DOI: 10.1016/j.jcct.2019.05.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2019] [Accepted: 05/02/2019] [Indexed: 01/25/2023]
Abstract
BACKGROUND Cardiac fat is emerging as an important parameter for cardiovascular risk stratification. Accurate and reproducible volumetric measurements can facilitate in the serial assessment of cardiac fat by computed tomography (CT). We assessed the intra- and inter-observer variability of cardiac fat volumetric measurements using a semi-automated CT software. METHODS We used non-contrast coronary calcium CT scans to quantify epicardial and intra-thoracic fat volumes. Two expert readers analyzed baseline and follow up CT scans of 45 subjects by using a semi-automated CT software (QFAT 2.0, Cedars Sinai-Medical Center). Correlation and Bland-Altman analysis was performed for both intra- and inter-observer comparisons for each cardiac fat type. RESULTS The intra-observer correlation coefficients ranged between 0.86 to 0.99 and 0.87 to 0.99 for epicardial (median fat per reader (cm3) 20.9 to 25.7) and intra-thoracic (median fat per reader (cm3) 27.1 to 31.6) fat volumes respectively, with no significant differences between individual data points (all p > 0.38). The inter-observer correlation coefficient was 0.99 (p < 0.0001 for correlation) for both epicardial and intra-thoracic fat. By Bland-Altman analysis for epicardial fat measurements, mean difference of intra-observer was 0.90 cm3 with 95% confidence intervals (0.22,1.7) and -1.8 cm3 for inter-observer, with 95% CI (-2.9, -0.69). Bland-Altman plots for intra-thoracic fat measurements were similarly impressive for both inter- and intra-observer reads. CONCLUSIONS Our data showed that measuring epicardial and intra-thoracic fat volumes by CT using a semi-automated software has excellent intra-observer and inter-observer reliability. Cardiac fat volumes can be obtained easily and reproducibly from routine calcium scoring scans and may help in assessing cardiovascular risk. CLINICAL TRIAL REGISTRATION URL: https://www.clinicaltrials.gov. Unique identifier: NCT00154180; Keywords: Epicardial fat volume; intra-thoracic fat volume; computed tomography; intra-observer; inter-observer.
Collapse
|
19
|
CORONARY PLAQUE PROGRESSION WITH ADVANCING AGE. J Am Coll Cardiol 2019. [DOI: 10.1016/s0735-1097(19)32159-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
20
|
Changes in Coronary Plaque Volume: Comparison of Serial Measurements on Intravascular Ultrasound and Coronary Computed Tomographic Angiography. Tex Heart Inst J 2018; 45:84-91. [PMID: 29844740 DOI: 10.14503/thij-15-5212] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Serial measurements of coronary plaque volume have been used to evaluate drug efficacy in atherosclerotic progression. However, the usefulness of computed tomography for this purpose is unknown. We investigated whether the change in total plaque volume on coronary computed tomographic angiography is associated with the change in segment plaque volume on intravascular ultrasound. We prospectively enrolled 11 consecutive patients (mean age, 56.3 ± 5 yr; 6 men) who were to undergo serial invasive coronary angiographic examinations with use of grayscale intravascular ultrasound and coronary computed tomography, performed <180 days apart at baseline and from 1 to 2 years later. Subjects underwent 186 serial measurements of total plaque volume on coronary computed tomography and 22 of segmental plaque volume on intravascular ultrasound. We used semiautomated software to examine percentage relationships and changes between total plaque and segmental plaque volumes. No significant correlations were found between percentages of total coronary and segment coronary plaque volume, nor between normalized coronary plaque volume. However, in the per-patient analysis, there were strong correlations between the imaging methods for changes in total coronary and segment coronary plaque volume (r=0.62; P=0.04), as well as normalized plaque volume (r=0.82; P=0.002). Per-patient change in plaque volume on coronary computed tomography is significantly associated with that on intravascular ultrasound. Computed tomographic angiography may be safer and more widely available than intravascular ultrasound for evaluating atherosclerotic progression in coronary arteries. Larger studies are warranted.
Collapse
|
21
|
Automated estimation of image quality for coronary computed tomographic angiography using machine learning. Eur Radiol 2018; 28:4018-4026. [PMID: 29572635 DOI: 10.1007/s00330-018-5348-8] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Revised: 01/15/2018] [Accepted: 01/23/2018] [Indexed: 11/24/2022]
Abstract
OBJECTIVES Our goal was to evaluate the efficacy of a fully automated method for assessing the image quality (IQ) of coronary computed tomography angiography (CCTA). METHODS The machine learning method was trained using 75 CCTA studies by mapping features (noise, contrast, misregistration scores, and un-interpretability index) to an IQ score based on manual ground truth data. The automated method was validated on a set of 50 CCTA studies and subsequently tested on a new set of 172 CCTA studies against visual IQ scores on a 5-point Likert scale. RESULTS The area under the curve in the validation set was 0.96. In the 172 CCTA studies, our method yielded a Cohen's kappa statistic for the agreement between automated and visual IQ assessment of 0.67 (p < 0.01). In the group where good to excellent (n = 163), fair (n = 6), and poor visual IQ scores (n = 3) were graded, 155, 5, and 2 of the patients received an automated IQ score > 50 %, respectively. CONCLUSION Fully automated assessment of the IQ of CCTA data sets by machine learning was reproducible and provided similar results compared with visual analysis within the limits of inter-operator variability. KEY POINTS • The proposed method enables automated and reproducible image quality assessment. • Machine learning and visual assessments yielded comparable estimates of image quality. • Automated assessment potentially allows for more standardised image quality. • Image quality assessment enables standardization of clinical trial results across different datasets.
Collapse
|
22
|
RELIABILITY OF CARDIAC FAT VOLUMES MEASURED BY NON-CONTRAST CORONARY CALCIUM COMPUTED TOMOGRAPHY USING A SEMI-AUTOMATED CARDIAC FAT ANALYSIS SOFTWARE. J Am Coll Cardiol 2018. [DOI: 10.1016/s0735-1097(18)32227-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
23
|
The relationship between cardio-ankle vascular index and subclinical atherosclerosis evaluated by cardiac computed tomographic angiography. Clin Cardiol 2017; 40:549-553. [PMID: 28272814 DOI: 10.1002/clc.22695] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2016] [Revised: 01/30/2017] [Accepted: 02/01/2017] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND The cardio-ankle vascular index (CAVI) is a new noninvasive index to evaluate arterial stiffness. We investigated whether CAVI can predict severity, extent, and burden of coronary artery disease by comparing results with cardiac computed tomographic angiography (CCTA). HYPOTHESIS CAVI may predict the presence of subclinical atherosclerosis. METHODS We prospectively enrolled 95 patients (66% male; mean age, 50 ± 16 years) who underwent both CCTA and CAVI consecutively. We evaluated if CAVI correlated with (1) severe stenosis (≥50%); (2) plaque extent, determined by a segment-involvement score (SIS), defined by the total number of coronary artery segments containing any plaque; and (3) plaque burden, determined by a segment-stenosis score (SSS), defined by the extent of obstruction of coronary luminal diameter in individual coronary artery segments. RESULTS Bivariate analysis showed a statistically significant relationship not only between CAVI and SIS, but also between CAVI and SSS (r2 = 0.4, P < 0.0001 for SIS; r2 = 0.36, P < 0.0001 for SSS). Multivariable logistic analysis demonstrated that CAVI is significantly associated with SSS >5 (odds ratio [OR]: 2.3, 95% confidence interval [CI]: 1.1-7.8, P = 0.03) and SIS >5 (OR: 2.3, 95% CI: 1.1-5.8, P = 0.02), but not severe stenosis (OR: 1.7, 95% CI: 0.9-4.3, P = 0.13), after adjusting for age, sex, chest pain, hypertension, dyslipidemia, family history, diabetes, and current smoking. CONCLUSIONS We demonstrated that CAVI had a significant relationship with subclinical coronary atherosclerosis evaluated by CCTA, especially in relation to plaque burden and plaque extent, but not severe stenosis. Thus, CAVI may reflect coronary atherosclerosis burden more than severity.
Collapse
|
24
|
Plaque progression assessed by a novel semi-automated quantitative plaque software on coronary computed tomography angiography between diabetes and non-diabetes patients: A propensity-score matching study. Atherosclerosis 2016; 255:73-79. [PMID: 27835741 DOI: 10.1016/j.atherosclerosis.2016.11.004] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2016] [Revised: 10/26/2016] [Accepted: 11/02/2016] [Indexed: 12/31/2022]
Abstract
BACKGROUND AND AIMS We aimed at investigating whether diabetes is associated with progression in coronary plaque components. METHODS We identified 142 study subjects undergoing serial coronary computed tomography angiography. The resulting propensity score was applied 1:1 to match diabetic patients to non-diabetic patients for clinical risk factors, prior coronary stenting, coronary artery calcium (CAC) score and the serial scan interval, resulting in the 71 diabetes and 71 non-diabetes patients. Coronary plaque (total, calcified, non-calcified including fibrous, fibrous-fatty and low attenuation plaque [LAP]) volume normalized by total coronary artery length was measured using semi-automated plaque software and its change overtime between diabetic and non-diabetic patients was evaluated. RESULTS The matching was successful without significant differences between the two groups in all matched variables. The baseline volumes in each plaque also did not differ. During a mean scan interval of 3.4 ± 1.8 years, diabetic patients showed a 2-fold greater progression in normalized total plaque volume (TPV) than non-diabetes patients (52.8 mm3vs. 118.3 mm3, p = 0.005). Multivariable linear regression model revealed that diabetes was associated with normalized TPV progression (β 72.3, 95%CI 24.3-120.3). A similar trend was observed for the non-calcified components, but not calcified plaque (β 3.8, 95%CI -27.0-34.7). Higher baseline CAC score was found to be associated with total, non-calcified and calcified plaque progression. However, baseline non-calcified volume but not CAC score was associated with LAP progression. CONCLUSIONS The current study among matched patients indicates diabetes is associated with a greater plaque progression. Our results show the need for strict adherence of diabetic patients to the current preventive guidelines.
Collapse
|
25
|
THE IMPACT OF DIABETES ON CORONARY PLAQUE PROGRESSION ASSESSED BY NOVEL SEMI-AUTOMATED QUANTITATIVE PLAQUE SOFTWARE ON CORONARY COMPUTED TOMOGRAPHIC ANGIOGRAPHY. J Am Coll Cardiol 2016. [DOI: 10.1016/s0735-1097(16)31750-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
26
|
Aged Garlic Extract Reduces Low Attenuation Plaque in Coronary Arteries of Patients with Metabolic Syndrome in a Prospective Randomized Double-Blind Study. J Nutr 2016; 146:427S-432S. [PMID: 26764322 DOI: 10.3945/jn.114.202424] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2014] [Accepted: 04/01/2015] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Although several previous studies have demonstrated that aged garlic extract (AGE) inhibits the progression of coronary artery calcification, its effect on noncalcified plaque (NCP) has been unclear. OBJECTIVE This study investigated whether AGE reduces coronary plaque volume measured by cardiac computed tomography angiography (CCTA) in patients with metabolic syndrome (MetS). METHODS Fifty-five patients with MetS (mean ± SD age: 58.7 ± 6.7 y; 71% men) were prospectively assigned to consume 2400 mg AGE/d (27 patients) or placebo (28 patients) orally. Both groups underwent CCTA at baseline and follow-up 354 ± 41 d apart. Coronary plaque volume, including total plaque volume (TPV), dense calcium (DC), NCP, and low-attenuation plaque (LAP), were measured based upon predefined intensity cutoff values. Multivariable linear regression analysis, adjusted for age, gender, number of risk factors, hyperlipidemia medications, history of coronary artery disease, scan interval time, and baseline %TPV, was performed to examine whether AGE affected each plaque change. RESULTS The %LAP change was significantly reduced in the AGE group compared with the placebo group (-1.5% ± 2.3% compared with 0.2% ± 2.0%, P = 0.0049). In contrast, no difference was observed in %TPV change (0.3% ± 3.3% compared with 1.6% ± 3.0%, P = 0.13), %NCP change (0.2% ± 3.3% compared with 1.4% ± 2.9%, P = 0.14), and %DC change (0.2% ± 1.4%, compared with 0.2% ± 1.7%, P = 0.99). Multivariable linear regression analysis found a beneficial effect of AGE on %LAP regression (β: -1.61; 95% CI: -2.79, -0.43; P = 0.008). CONCLUSIONS This study indicates that the %LAP change was significantly greater in the AGE group than in the placebo group. Further studies are needed to evaluate whether AGE has the ability to stabilize vulnerable plaque and decrease adverse cardiovascular events. This trial was registered at clinicaltrials.gov as NCT01534910.
Collapse
|
27
|
All-cause mortality by age and gender based on coronary artery calcium scores. Eur Heart J Cardiovasc Imaging 2015; 17:1305-1314. [PMID: 26705490 PMCID: PMC6392424 DOI: 10.1093/ehjci/jev328] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2015] [Accepted: 11/19/2015] [Indexed: 01/07/2023] Open
Abstract
AIMS Although coronary artery calcium (CAC) has been established as a robust tool for predicting total mortality during intermediate follow-up, less is known about the long-term predictive value of CAC. METHODS AND RESULTS This study included 13 092 asymptomatic patients without known cardiovascular disease who underwent a clinically indicated CAC scan. CAC was categorized as an Agatson score of 0, 1-99, 100-399, and ≥400. We used multivariable Cox proportional hazards to calculate adjusted hazard ratios (HRs) for mortality stratified by age (younger, intermediate, or older) and gender. The mean age of participants was 58 ± 11 years and 67% were men. During a median follow-up of 11.0 ± 3.2 years, there were 522 deaths (4.0%). Compared with CAC = 0, increasing CAC was associated with higher mortality rate: 1-99 [HR: 1.5, 95% confidence interval (95% CI): 1.1-2.1]; 100-399 (HR: 1.8, 95% CI: 1.3-2.5); ≥400 (HR: 2.6, 95% CI: 1.9-3.6). Relative risk according to CAC category did not differ between genders. The strongest associations between CAC and mortality were observed for young and intermediate age participants. Nonetheless, the mortality rate of the older patients with CAC = 0 was far lower than that of the general US population. CAC was more predictive of long-term (15 years) than intermediate-term (5 years) mortality for men [receiver operator characteristics (ROC): 0.723 vs. 0.702] and women (ROC: 0.69 vs. 0.65). CONCLUSION CAC is strongly associated with the long-term risk of mortality in young- and middle-aged men and women. In older patients, the long-term risk stratification of CAC is lower, due principally to increased mortality rate in patients with low calcium scores; however, even in the older patients, those with absent or low CAC are at a significantly lower risk of mortality compared with the general population.
Collapse
|
28
|
CORONARY ARTERY CALCIUM SCORE PREDICTS THE LONG-TERM MORTALITY AMONG PATIENTS WITH NO OR MINIMAL CORONARY ARTERY RISK FACTOR DURING 20 YEARS OBSERVATION. J Am Coll Cardiol 2014. [DOI: 10.1016/s0735-1097(14)60979-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|