1
|
Development of an MR-Guided Focused Ultrasound (MRgFUS) Lesioning Approach for the Fornix in the Rat Brain. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:920-926. [PMID: 38521695 DOI: 10.1016/j.ultrasmedbio.2024.02.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 02/01/2024] [Accepted: 02/26/2024] [Indexed: 03/25/2024]
Abstract
OBJECTIVE High-intensity magnetic resonance-guided focused ultrasound (MRgFUS) is a non-invasive therapy to lesion brain tissue, used clinically in patients and pre-clinically in several animal models. Challenges with focused ablation in rodent brains can include skull and near-field heating and accurately targeting small and deep brain structures. We overcame these challenges by creating a novel method consisting of a craniectomy skull preparation, a high-frequency transducer (3 MHz) with a small ultrasound focal spot, a transducer positioning system with an added manual adjustment of ∼0.1 mm targeting accuracy, and MR acoustic radiation force imaging for confirmation of focal spot placement. METHODS The study consisted of two main parts. First, two skull preparation approaches were compared. A skull thinning approach (n = 7 lesions) was compared to a craniectomy approach (n = 22 lesions), which confirmed a craniectomy was necessary to decrease skull and near-field heating. Second, the two transducer positioning systems were compared with the fornix chosen as a subcortical ablation target. We evaluated the accuracy of targeting using histologic methods from a high-frequency transducer with a small ultrasound focal spot and MR acoustic radiation force imaging. RESULTS Comparing a motorized adjustment system (∼1 mm precision, n = 17 lesions) to the motorized system with an added micromanipulator (∼0.1 mm precision, n = 14 lesions), we saw an increase in the accuracy of targeting the fornix by 133%. CONCLUSIONS The described work allows for repeatable and accurate targeting of small and deep structures in the rodent brain, such as the fornix, enabling the investigation of neurological disorders in chronic disease models.
Collapse
|
2
|
Validation of single reference variable flip angle (SR-VFA) dynamic T 1 mapping with T 2 * correction using a novel rotating phantom. Magn Reson Med 2024; 91:1419-1433. [PMID: 38115639 PMCID: PMC10872756 DOI: 10.1002/mrm.29944] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 10/12/2023] [Accepted: 11/09/2023] [Indexed: 12/21/2023]
Abstract
PURPOSE To validate single reference variable flip angle (SR-VFA) dynamic T1 mapping with and without T2 * correction against inversion recovery (IR) T1 measurements. METHODS A custom cylindrical phantom with three concentric compartments was filled with variably doped agar to produce a smooth spatial gradient of the T1 relaxation rate as a function of angle across each compartment. IR T1 , VFA T1 , and B1 + measurements were made on the phantom before rotation, and multi-echo stack-of-radial dynamic images were acquired during rotation via an MRI-compatible motor. B1 + -corrected SR-VFA and SR-VFA-T2 * T1 maps were computed from the sliding window reconstructed images and compared against rotationally registered IR and VFA T1 maps to determine the percentage error. RESULTS Both VFA and SR-VFA-T2 * T1 maps fell within 10% of IR T1 measurements for a low rotational speed, with a mean accuracy of 2.3% ± 2.6% and 2.8% ± 2.6%, respectively. Increasing rotational speed was found to decrease the accuracy due to increasing temporal smoothing over ranges where the T1 change had a nonconstant slope. SR-VFA T1 mapping was found to have similar accuracy as the SR-VFA-T2 * and VFA methods at low TEs (˜<2 ms), whereas accuracy degraded strongly with later TEs. T2 * correction of the SR-VFA T1 maps was found to consistently improve accuracy and precision, especially at later TEs. CONCLUSION SR-VFA-T2 * dynamic T1 mapping was found to be accurate against reference IR T1 measurements within 10% in an agar phantom. Further validation is needed in mixed fat-water phantoms and in vivo.
Collapse
|
3
|
MR-Guided Focused Ultrasound Thalamotomy in the Setting of Aneurysm Clip. AJNR Am J Neuroradiol 2024; 45:302-304. [PMID: 38272573 DOI: 10.3174/ajnr.a8109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 12/04/2023] [Indexed: 01/27/2024]
Abstract
We report on a 75-year-old woman with a history of right MCA aneurysm clipping and medically refractive right-hand tremor. We successfully performed focused ultrasound thalamotomy of the left ventral intermediate nucleus under MR imaging-guidance at 3T. A thorough pretreatment evaluation of MR thermometry was critical to ensure that adequate precision could be achieved at the intended target. The tremor showed a 75% decrease at 24 hours postprocedure and a 50% decrease at a 3-month follow-up. There were no immediate adverse events.
Collapse
|
4
|
The influence of bone model geometries on the determination of skull acoustic properties. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3779. [PMID: 37794748 PMCID: PMC10841890 DOI: 10.1002/cnm.3779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 04/06/2023] [Accepted: 09/04/2023] [Indexed: 10/06/2023]
Abstract
In this study, we investigated the impact of various simulated skull bone geometries on the determination of skull speed of sound and acoustic attenuation values via optimization using transmitted pressure amplitudes beyond the bone. Using the hybrid angular spectrum method (HAS), we simulated ultrasound transmission through four model sets of different geometries involving sandwiched layers of diploë and cortical bone in addition to three models generated from CT images of ex-vivo human skull-bones. We characterized cost-function solution spaces for each model and, using optimization, found that when a model possessed appreciable variations in resolvable layer thickness, the predefined attenuation coefficients could be found with low error (RMSE < 0.01 Np/cm). However, we identified a spatial frequency cutoff in the models' geometry beyond which the accuracy of the property determination begins to fail, depending on the frequency of the ultrasound source. There was a large increase in error of the attenuation coefficients determined by the optimization when the variations in layer thickness were above the identified spatial frequency cutoffs, or when the lateral variations across the model were relatively low in amplitude. For our limited sample of three CT-image derived bone models, the attenuation coefficients were determined successfully. The speed of sound values were determined with low error for all models (including the CT-image derived models) that were tested (RMSE < 0.4 m/s). These results illustrate that it is possible to determine the acoustic properties of two-component models when the internal bone structure is taken into account and the structure satisfies the spatial frequency constraints discussed.
Collapse
|
5
|
Evaluation of methemoglobin as an intravascular contrast agent: T1 relaxation time effect in a rabbit model. Magn Reson Imaging 2023; 103:1-7. [PMID: 37392804 PMCID: PMC10530177 DOI: 10.1016/j.mri.2023.06.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 06/28/2023] [Indexed: 07/03/2023]
Abstract
OBJECTIVE Alternative contrast agents for MRI are needed for individuals who may respond adversely to gadolinium, and need an intravascular agent for specific indications. One potential contrast agent is intracellular methemoglobin, a paramagnetic molecule that is normally present in small amounts in red blood cells. An animal model was used to determine whether methemoglobin modulation with intravenous sodium nitrite transiently changes the T1 relaxation of blood. METHODS Four adult New Zealand white rabbits were treated with 30 mg intravenous sodium nitrite. 3D TOF and 3D MPRAGE images were acquired before (baseline) and after methemoglobin modulation. T1 of blood was measured with 2D ss EPl acquisitions with inversion recovery preparation performed at two-minute intervals up to 30 min. T1 maps were calculated by fitting the signal recovery curve within major blood vessels. RESULTS Baseline T1 was 1758 ± 53 ms in carotid arteries and 1716 ± 41 ms in jugular veins. Sodium nitrite significantly changed intravascular T1 relaxation. The mean minimum value of T1 was 1126 ± 28 ms in carotid arteries 8 to 10 min after the injection of sodium nitrite. The mean minimum value of T1 was 1171 ± 52 ms in jugular veins 10 to 14 min after the injection of sodium nitrite. Arterial and venous T1 recovered to baseline after a period of 30 min. CONCLUSION Methemoglobin modulation produces intravascular contrast on T1-weighted MRI in vivo. Additional studies are needed to safely optimize methemoglobin modulation and sequence parameters for maximal tissue contrast.
Collapse
|
6
|
Influence of cerebrospinal fluid on power absorption during transcranial magnetic resonance-guided focused ultrasound treatment. Med Phys 2023; 50:3245-3257. [PMID: 37078516 PMCID: PMC10330438 DOI: 10.1002/mp.16427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 04/06/2023] [Accepted: 04/06/2023] [Indexed: 04/21/2023] Open
Abstract
BACKGROUND Ultrasound beam aberration correction is vital when focusing ultrasound through the skull bone in transcranial magnetic resonance-guided focused ultrasound (tcMRgFUS) applications. Current methods make transducer element phase adjustments to compensate for the variation in skull properties (shape, thickness, and acoustic properties), but do not account for variations in the internal brain anatomy. PURPOSE Our objective is to investigate the effect of cerebrospinal fluid (CSF) and brain anatomy on beam focusing in tcMRgFUS treatments. METHODS Simulations were conducted with imaging data from 20 patients previously treated with focused ultrasound for disabling tremor. The Hybrid Angular Spectrum (HAS) method was used to test the effect of including cerebral spinal fluid (CSF) and brain anatomy in determining the element phases used for aberration correction and beam focusing. Computer tomography (CT) and magnetic resonance imaging (MRI) images from patient treatments were used to construct a segmented model of each patient's head. The segmented model for treatment simulation consisted of water, skin, fat, brain, CSF, diploë, and cortical bone. Transducer element phases used for treatment simulation were determined using time reversal from the desired focus, generating a set of phases assuming a homogeneous brain in the intracranial volume, and a second set of phases assigning CSF acoustic properties to regions of CSF. In addition, for three patients, the relative effect of separately including CSF speed of sound values compared to CSF attenuation values was found. RESULTS We found that including CSF acoustic properties (speed of sound and attenuation) during phase planning compared to phase correction without considering CSF increased the absorbed ultrasound power density ratios at the focus over a range of 1.06 to 1.29 (mean of 17% ± 6%) for 20 patients. Separately considering the CSF speed of sound and CSF attenuation showed that the increase was due almost entirely to including the CSF speed of sound; considering only the CSF attenuation had a negligible effect. CONCLUSIONS Based on HAS simulations, treatment planning phase determination using morphologically realistic CSF and brain anatomy yielded an increase of up to 29% in the ultrasound focal absorbed power density. Future work will be required to validate the CSF simulations.
Collapse
|
7
|
Simultaneous proton resonance frequency T 1 - MR shear wave elastography for MR-guided focused ultrasound multiparametric treatment monitoring. Magn Reson Med 2023; 89:2171-2185. [PMID: 36656135 PMCID: PMC10940047 DOI: 10.1002/mrm.29587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 12/21/2022] [Accepted: 12/30/2022] [Indexed: 01/20/2023]
Abstract
PURPOSE To develop an efficient MRI pulse sequence to simultaneously measure multiple parameters that have been shown to correlate with tissue nonviability following thermal therapies. METHODS A 3D segmented EPI pulse sequence was used to simultaneously measure proton resonance frequency shift (PRFS) MR thermometry (MRT), T1 relaxation time, and shear wave velocity induced by focused ultrasound (FUS) push pulses. Experiments were performed in tissue mimicking gelatin phantoms and ex vivo bovine liver. Using a carefully designed FUS triggering scheme, a heating duty cycle of approximately 65% was achieved by interleaving FUS ablation pulses with FUS push pulses to induce shear waves in the tissue. RESULTS In phantom studies, temperature increases measured with PRFS MRT and increases in T1 correlated with decreased shear wave velocity, consistent with material softening with increasing temperature. During ablation in ex vivo liver, temperature increase measured with PRFS MRT initially correlated with increasing T1 and decreasing shear wave velocity, and after tissue coagulation with decreasing T1 and increasing shear wave velocity. This is consistent with a previously described hysteresis in T1 versus PRFS curves and increased tissue stiffness with tissue coagulation. CONCLUSION An efficient approach for simultaneous and dynamic measurements of PRSF, T1 , and shear wave velocity during treatment is presented. This approach holds promise for providing co-registered dynamic measures of multiple parameters, which correlates to tissue nonviability during and following thermal therapies, such as FUS.
Collapse
|
8
|
Validation of a drift-corrected 3D MR temperature imaging sequence for breast MR-guided focused ultrasound treatments. Magn Reson Imaging 2023; 96:126-134. [PMID: 36496098 PMCID: PMC9810259 DOI: 10.1016/j.mri.2022.12.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 11/11/2022] [Accepted: 12/04/2022] [Indexed: 12/12/2022]
Abstract
Real-time temperature monitoring is critical to the success of thermally ablative therapies. This work validates a 3D thermometry sequence with k-space field drift correction designed for use in magnetic resonance-guided focused ultrasound treatments for breast cancer. Fiberoptic probes were embedded in tissue-mimicking phantoms, and temperature change measurements from the probes were compared with the magnetic resonance temperature imaging measurements following heating with focused ultrasound. Precision and accuracy of measurements were also evaluated in free-breathing healthy volunteers (N = 3) under a non-heating condition. MR temperature measurements agreed closely with those of fiberoptic probes, with a 95% confidence interval of measurement difference from -2.0 °C to 1.4 °C. Field drift-corrected measurements in vivo had a precision of 1.1 ± 0.7 °C and were accurate within 1.3 ± 0.9 °C across the three volunteers. The field drift correction method improved precision and accuracy by an average of 46 and 42%, respectively, when compared to the uncorrected data. This temperature imaging sequence can provide accurate measurements of temperature change in aqueous tissues in the breast and support the use of this sequence in clinical investigations of focused ultrasound treatments for breast cancer.
Collapse
|
9
|
Correction of heat-induced susceptibility changes in respiratory-triggered 2D-PRF-based thermometry for monitoring of magnetic resonance-guided hepatic microwave ablation in a human-like in vivo porcine model. Int J Hyperthermia 2022; 39:1387-1396. [DOI: 10.1080/02656736.2022.2138987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
|
10
|
A k-space-based method to measure and correct for temporal B 0 field variations in MR temperature imaging. Magn Reson Med 2022; 88:1098-1111. [PMID: 35576148 PMCID: PMC11034809 DOI: 10.1002/mrm.29275] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 03/29/2022] [Accepted: 04/01/2022] [Indexed: 11/10/2022]
Abstract
PURPOSE Present a method to use change in phase in repeated Cartesian k-space measurements to monitor the change in magnetic field for dynamic MR temperature imaging. METHODS The method is applied to focused ultrasound heating experiments in a gelatin phantom and an ex vivo salt pork sample, without and with simulated respiratory motion. RESULTS In each experiment, phase variations due to B0 field drift and respiration were readily apparent in the measured phase difference. With correction, the SD of the temperature over time was reduced from 0.18°C to 0.14°C (no breathing) and from 0.81°C to 0.22°C (with breathing) for the gelatin phantom, and from 0.68°C to 0.13°C (no breathing) and from 1.06°C to 0.17°C (with breathing) for the pork sample. The accuracy in nonheated regions, assessed as the RMS error deviation from 0°C, improved from 1.70°C to 1.11°C (no breathing) and from 4.73°C to 1.47°C (with breathing) for the gelatin phantom, and from 5.95°C to 0.88°C (no breathing) and from 13.40°C to 1.73°C (with breathing) for the pork sample. The correction did not affect the temperature measurement accuracy in the heated regions. CONCLUSION This work demonstrates that phase changes resulting from variations in B0 due to drift and respiration, commonly seen in MR thermometry applications, can be measured directly from 3D Cartesian acquisition methods. The correction of temporal field variations using the presented technique improved temperature accuracy, reduced variability in nonheated regions, and did not reduce accuracy in heated regions.
Collapse
|
11
|
MRI-compatible electromagnetic servomotor for image-guided medical robotics. COMMUNICATIONS ENGINEERING 2022; 1:4. [PMID: 36700241 PMCID: PMC9873480 DOI: 10.1038/s44172-022-00001-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Accepted: 02/22/2022] [Indexed: 02/01/2023]
Abstract
The soft-tissue imaging capabilities of magnetic resonance imaging (MRI) combined with high precision robotics has the potential to improve the precision and safety of a wide range of image-guided medical procedures. However, functional MRI-compatible robotics have not yet been realized in part because conventional electromagnetic servomotors can become dangerous projectiles near the strong magnetic field of an MRI scanner. Here we report an electromagnetic servomotor constructed from non-magnetic components, where high-torque and controlled rotary actuation is produced via interaction between electrical current in the servomotor armature and the magnetic field generated by the superconducting magnet of the MRI scanner itself. Using this servomotor design, we then build and test an MRI-compatible robot which can achieve the linear forces required to insert a large-diameter biopsy instrument in tissue during simultaneous MRI. Our electromagnetic servomotor can be safely operated (while imaging) in the patient area of a 3 Tesla clinical MRI scanner.
Collapse
|
12
|
Effects of T 2 * on accuracy and precision of dynamic T 1 measurements using the single reference variable flip angle method - a simulation study. Med Phys 2022; 49:2396-2412. [PMID: 35066898 PMCID: PMC9007881 DOI: 10.1002/mp.15476] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 01/05/2021] [Accepted: 01/07/2021] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To study in simulation and in theory the accuracy and precision of dynamic T1 measurements obtained using the previously published single-reference variable flip angle (SR-VFA) technique, with a focus on the effects of dynamic changes in T2 * on the calculation. METHODS Monte Carlo simulations were performed over 1000 noisy iterations for the VFA method, the SR-VFA method, and a proposed method, SR-VFA with a T2 * correction (SR-VFA-T2 *). Dynamic T1 estimates were calculated analytically for each method, with signals modeled by the steady-state spoiled gradient echo equation. The mean and standard deviation of these estimates were calculated and compared to truth, while varying repetition time (TR), baseline and dynamic T1 , echo time (TE), baseline and dynamic T2 *, flip angles, and the number of averages on baseline scans. Additionally, the variance of T1 in the SR-VFA and SR-VFA-T2 * methods was derived analytically based on the theory of propagation of errors. This equation was used to produce an inverse-variance weighted linear combination to improve T1 mapping precision in the SR-VFA-T2 * method. Flip angle sensitivity of dynamic T1 precision in the SR-VFA and SR-VFA-T2 * methods was also performed. RESULTS Substantial bias can be produced by the SR-VFA method when the ratio of the T2 * decay of the dynamic signal versus that of the baseline signals deviates from 1, with a 0.01 deviation leading to approximately a 1% bias in cases of high SNR and TR ≫ T1 . This bias can be corrected by estimating the baseline and dynamic T2 * values in this ratio via multi-echo measurements. The bias and precision of the SR-VFA-T2 * method, when normalized to scan time, is found to rival and sometimes improve upon the two flip angle VFA method when an inverse variance weighted linear combination is applied across its multi-echo T1 maps. The analytic variance equation presented is found to be accurate within 1% relative to the Monte Carlo simulations over a broad parameter space. Flip angle ranges that maximize SR-VFA and SR-VFA-T2 * T1 precision over a broad parameter space are given, and each is defined relative to TR and T1 . CONCLUSIONS Multi-echo SR-VFA-T2 * T1 mapping is found in simulation and theory to be a promising alternative to the VFA method that maintains speed of the SR-VFA method with accuracy and precision similar to the VFA method. This article is protected by copyright. All rights reserved.
Collapse
|
13
|
Improving image quality in transcranial magnetic resonance guided focused ultrasound using a conductive screen. Magn Reson Imaging 2021; 83:41-49. [PMID: 34242694 PMCID: PMC8449813 DOI: 10.1016/j.mri.2021.07.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Accepted: 07/03/2021] [Indexed: 10/20/2022]
Abstract
Transcranial Magnetic Resonance guided Focused Ultrasound (TcMRgFUS) has been proven to be an effective treatment for some neurological disorders such as essential and Parkinson's tremor. However, magnetic resonance guidance at 3 Tesla (3T) frequencies and using the large hemispherical transducers required for TcMRgFUS results in artifactual low-signal bands that pass through key regions of the brain. The purpose of this work was to investigate the use of a circular conductive Radio Frequency (RF) screen, that is bent to have a 12 cm radius in one direction and positioned near the top or back of the head, to reduce or remove these artifactual low-signal bands in TcMRgFUS. The impact of using an RF screen to remove these low signal bands was studied in both imaging experiments and electromagnetic simulations. Hydrophone measurements of the acoustic transparency of the bronze 2 mm diameter square mesh screen used in the imaging studies were compared with temperature measurements with and without the screen in heating studies in the TcMRgFUS system. The imaging and simulation studies both show that for the different screen configurations studied in this work, RF screen removes the low-signal bands and increases both homogeneity and signal-to-noise ratio (SNR) throughout the region of the brain. Hydrophone and heating studies indicate that even a 2 mm wire mesh provides minimal attenuation to the ultrasound beam. Simulation results also suggest that a 1 cm mesh will provide adequate artifact suppression with even less ultrasound attenuation. An RF screen that disrupts the natural waveguide nature of the transducer in the 3T MR environment can change the electromagnetic field profile to reduce unwanted artifacts and provide an imaging region which has more homogeneity and higher SNR throughout the brain.
Collapse
|
14
|
Differentiation of symptomatic and asymptomatic carotid intraplaque hemorrhage using 3D high-resolution diffusion-weighted stack of stars imaging. NMR IN BIOMEDICINE 2021; 34:e4582. [PMID: 34296793 DOI: 10.1002/nbm.4582] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Revised: 06/14/2021] [Accepted: 06/15/2021] [Indexed: 06/13/2023]
Abstract
Ischemic events related to carotid disease are far more strongly associated with plaque instability than stenosis. 3D high-resolution diffusion-weighted (DW) imaging can provide quantitative diffusion measurements on carotid atherosclerosis and may improve detection of vulnerable intraplaque hemorrhage (IPH). The 3D DW-stack of stars (SOS) sequence was implemented with 3D SOS acquisition combined with DW preparation. After simulation of signals created from 3D DW-SOS, phantom studies were performed. Three healthy subjects and 20 patients with carotid disease were recruited. Apparent diffusion coefficient (ADC) values were statistically analyzed on three subgroups by using a two-group comparison Wilcoxon-Mann-Whitney U test with p values less than 0.05: symptomatic versus asymptomatic; IPH-positive versus IPH-negative; and IPH-positive symptomatic versus asymptomatic plaques to determine the relationship with plaque vulnerability. ADC values calculated by 3D DW-SOS provided values similar to those calculated from other techniques. Mean ADC of symptomatic plaque was significantly lower than asymptomatic plaque (0.68 ± 0.18 vs. 0.98 ± 0.16 x 10-3 mm2 /s, p < 0.001). ADC was also significantly lower in IPH-positive versus IPH-negative plaque (0.68 ± 0.13 vs. 1.04 ± 0.11 x 10-3 mm2 /s, p < 0.001). Additionally, ADC was significantly lower in symptomatic versus asymptomatic IPH-positive plaque (0.57 ± 0.09 vs. 0.75 ± 0.11 x 10-3 mm2 /s, p < 0.001). Our results provide strong evidence that ADC measurements from 3D DW-SOS correlate with the symptomatic status of extracranial internal carotid artery plaque. Further, ADC improved discrimination of symptomatic plaque in IPH. These data suggest that diffusion characteristics may improve detection of destabilized plaque leading to elevated stroke risk.
Collapse
|
15
|
Carotid Compliance and Parahippocampal and Hippocampal Volume over a 20-Year Period. Dement Geriatr Cogn Dis Extra 2021; 11:227-234. [PMID: 34721500 PMCID: PMC8543351 DOI: 10.1159/000518234] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 06/30/2021] [Indexed: 11/21/2022] Open
Abstract
INTRODUCTION We evaluated the association between carotid compliance, a measure of arterial stiffness, to parahippocampal volume (PHV) and hippocampal volume (HV) over 20 years later in the Atherosclerosis Risk in the Community study. METHODS We included participants with common carotid compliance measurements at visit 1 (1987-1989) and volumetric brain MRI at visit 5 (2011-2013). The primary outcomes are pooled bilateral PHV and HV. We performed linear regression models adjusting for age, sex, vascular risk factors, and total brain volume. RESULTS Of the 614 participants, higher compliance was correlated with higher PHV (R = 0.218[0.144-0.291], p < 0.001) and HV (R = 0.181 [0.105-0.255, p < 0.001]). The association was linear and significant after adjusting for confounders. At follow-up MRI, 30 patients with dementia had lower PHV and HV than patients without dementia (p < 0.001 and p < 0.001, respectively). CONCLUSION Carotid compliance is associated with higher PHV and HV when measured 20 years later, further supporting the link between arterial stiffness and cognitive decline.
Collapse
|
16
|
A T1-based correction method for proton resonance frequency shift thermometry in breast tissue. Med Phys 2021; 48:4719-4729. [PMID: 34265109 DOI: 10.1002/mp.15085] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 05/30/2021] [Accepted: 06/01/2021] [Indexed: 11/06/2022] Open
Abstract
PURPOSE Develop and evaluate the effectiveness of a T1-based correction method for errors in proton resonant frequency shift thermometry due to non-local field effects caused by heating in fatty breast tissues. METHODS Computational models of human breast tissue were created by segmenting MRI data from a healthy human volunteer. MR-guided focused ultrasound (MRgFUS) heating and MR thermometry measurements were simulated in several locations in the heterogeneous segmented breast models. A T1-based correction method for PRF thermometry errors was applied and the maximum positive and negative errors and the root mean squared error (RMSE) in a region around each heating location was evaluated with and without correction. The method uses T1 measurements to estimate the temperature change in fatty tissues and correct for their influence. Experimental data from a heating study in cadaver breast tissue were analyzed, and the expected PRFS error computed. RESULTS The simulated MR thermometry had maximum single voxel errors ranging between 10% and 18% when no correction was applied. Applying the correction led to a considerable improvement, lowering the maximum error range to 2%-5%. The 5th to 95th percentile interval of the temperature error distribution was also lowered with correction, from approximately 3.5 to 1°C. This correction worked even when T1 times were uniformly raised or lowered by 5%-10%. The experimental data showed predicted errors of 15%. CONCLUSIONS This simulation study demonstrates that the T1-based correction method reduces MR thermometry errors due to non-local effects from heating in fatty tissues, potentially improving the accuracy of thermometry measurements during MRgFUS treatments. The presented correction method is reliant on having a patient-specific 3D model of the breast, and may be limited by the accuracy of the fat temperatures which in turn may be limited by noise or bias present in the T1 measurements.
Collapse
|
17
|
Rabbit models of intracranial atherosclerotic disease for pathological validation of vessel wall MRI. Neuroradiol J 2021; 34:193-199. [PMID: 33325806 PMCID: PMC8165905 DOI: 10.1177/1971400920980153] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
INTRODUCTION Vessel wall magnetic resonance imaging can improve the evaluation of intracranial atherosclerotic disease. However, pathological validation is needed to improve vessel wall magnetic resonance imaging techniques. Human pathology samples are not practical for such analysis, so an animal model is therefore needed. MATERIALS AND METHODS Watanabe heritable hyperlipidemic rabbits and apolipoprotein E knockout rabbits were evaluated against New Zealand white wild-type rabbits. Evaluation of intracranial arteries was performed with vessel wall magnetic resonance imaging and pathological analysis, rating the presence and severity of disease in each segment. Two-tailed t-tests were performed to compare disease occurrence and severity prevalence among rabbit subtypes. Sensitivity and specificity were calculated to assess the diagnostic accuracy of vessel wall magnetic resonance imaging. RESULTS Seventeen rabbits (five Watanabe heritable hyperlipidemic, four apolipoprotein E knockout and eight New Zealand white) were analysed for a total of 51 artery segments. Eleven segments (five Watanabe heritable hyperlipidemic and six apolipoprotein E knockout) demonstrated intracranial atherosclerotic disease on pathology. Disease model animals had lesions more frequently than New Zealand white animals (P<0.001). The sensitivity and specificity of vessel wall magnetic resonance imaging for the detection of intracranial atherosclerotic disease were 68.8% and 95.2%, respectively. When excluding mild cases to assess vessel wall magnetic resonance imaging accuracy for detecting moderate to severe intracranial atherosclerotic disease lesions, sensitivity improved to 100% with unchanged specificity. CONCLUSION Intracranial atherosclerotic disease can be reliably produced and detected using 3T vessel wall magnetic resonance imaging-compatible Watanabe heritable hyperlipidemic and ApoE rabbit models. Further analysis is needed to characterize better the development and progression of the disease to correlate tissue-validated animal findings with those in human vessel wall magnetic resonance imaging studies.
Collapse
|
18
|
Quasistatic Solutions versus Full-Wave Solutions of Single-Channel Circular RF Receive Coils on Phantoms of Varying Conductivities at 3 Tesla. CONCEPTS IN MAGNETIC RESONANCE. PART B, MAGNETIC RESONANCE ENGINEERING 2021; 2021:6638576. [PMID: 34899097 PMCID: PMC8665417 DOI: 10.1155/2021/6638576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
PURPOSE Although full-wave simulations could be used to aid in RF coil design, the algorithms may be too slow for an iterative optimization algorithm. If quasistatic simulations are accurate within the design tolerance, then their use could reduce simulation time by orders of magnitude compared to full-wave simulations. This paper examines the accuracy of quasistatic and full-wave simulations at 3 Tesla. METHODS Three sets of eight coils ranging from 3-10 cm (24 total) were used to measure SNR on three phantoms with conductivities of 0.3, 0.6, and 0.9 S/m. The phantom conductivities were chosen to represent those typically found in human tissues. The range of coil element sizes represents the sizes of coil elements seen in typical coil designs. SNR was determined using the magnetic and electric fields calculated by quasistatic and full-wave simulations. Each simulated SNR dataset was scaled to minimize the root mean squared error (RMSE) when compared against measured SNR data. In addition, the noise values calculated by each simulation were compared against benchtop measured noise values. RESULTS The RMSE was 0.285 and 0.087 for the quasistatic and full-wave simulations, respectively. The maximum and minimum quotient values, when taking the ratio of simulated to measured SNR values, were 1.69 and 0.20 for the quasistatic simulations and 1.29 and 0.75 for the full-wave simulations, respectively. The ratio ranges, for the calculated quasistatic and full-wave total noise values compared to benchtop measured noise values, were 0.83-1.06 and 0.27-3.02, respectively. CONCLUSIONS Full-wave simulations were on average 3x more accurate than the quasistatic simulations. Full-wave simulations were more accurate in characterizing the wave effects within the sample, though they were not able to fully account for the skin effect when calculating coil noise.
Collapse
|
19
|
A Breast-Specific MR Guided Focused Ultrasound Platform and Treatment Protocol: First-in-Human Technical Evaluation. IEEE Trans Biomed Eng 2021; 68:893-904. [PMID: 32784128 PMCID: PMC7878578 DOI: 10.1109/tbme.2020.3016206] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
OBJECTIVE This paper presents and evaluates a breast-specific magnetic resonance guided focused ultrasound (MRgFUS) system. A first-in-human evaluation demonstrates the novel hardware, a sophisticated tumor targeting algorithm and a volumetric magnetic resonance imaging (MRI) protocol. METHODS At the time of submission, N = 10 patients with non-palpable T0 stage breast cancer have been treated with the breast MRgFUS system. The described tumor targeting algorithm is evaluated both with a phantom test and in vivo during the breast MRgFUS treatments. Treatments were planned and monitored using volumetric MR-acoustic radiation force imaging (MR-ARFI) and temperature imaging (MRTI). RESULTS Successful technical treatments were achieved in 80 % of the patients. All patients underwent the treatment with no sedation and 60 % of participants had analgesic support. The total MR treatment time ranged from 73 to 114 minutes. Mean error between desired and achieved targeting in a phantom was 2.9 ±1.8 mm while 6.2 ±1.9 mm was achieved in patient studies, assessed either with MRTI or MR-ARFI measurements. MRTI and MR-ARFI were successful in 60 % and 70 % of patients, respectively. CONCLUSION The targeting accuracy allows the accurate placement of the focal spot using electronic steering capabilities of the transducer. The use of both volumetric MRTI and MR-ARFI provides complementary treatment planning and monitoring information during the treatment, allowing the treatment of all breast anatomies, including homogeneously fatty breasts.
Collapse
|
20
|
Magnetic resonance shear wave elastography using transient acoustic radiation force excitations and sinusoidal displacement encoding. Phys Med Biol 2021; 66. [PMID: 33352538 DOI: 10.1088/1361-6560/abd5ce] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Accepted: 12/22/2020] [Indexed: 12/31/2022]
Abstract
A magnetic resonance (MR) shear wave elastography technique that uses transient acoustic radiation force impulses from a focused ultrasound (FUS) transducer and a sinusoidal-shaped MR displacement encoding strategy is presented. Using this encoding strategy, an analytic expression for calculating the shear wave speed in a heterogeneous medium was derived. Green's function-based simulations were used to evaluate the feasibility of calculating shear wave speed maps using the analytic expression. Accuracy of simulation technique was confirmed experimentally in a homogeneous gelatin phantom. The elastography measurement was compared to harmonic MR elastography in a homogeneous phantom experiment and the measured shear wave speed values differed by less than 14%. This new transient elastography approach was able to map the position and shape of inclusions sized from 8.5 to 14 mm in an inclusion phantom experiment. These preliminary results demonstrate the feasibility of using a straightforward analytic expression to generate shear wave speed maps from MR images where sinusoidal-shaped motion encoding gradients are used to encode the displacement-time history of a transiently propagating wave-packet. This new measurement technique may be particularly well suited for performing elastography before, during, and after MR-guided FUS therapies since the same device used for therapy is also used as an excitation source for elastography.
Collapse
|
21
|
Abstract
Background Stenosis has historically been the major factor used to determine carotid stroke sources. Recent evidence suggests that specific plaque features detected on imaging may be more highly associated with ischemic stroke than stenosis. We sought to determine computed tomography angiography (CTA) imaging features of carotid plaque that optimally discriminate ipsilateral stroke sources. Methods and Results In this institutional review board-approved retrospective cross-sectional study, 494 ipsilateral carotid CTA-brain magnetic resonance imaging pairs were available for analysis after excluding patients with alternative stroke sources. Carotid CTA and clinical markers were recorded, a multivariable Poisson regression model was fitted, and backward elimination was performed with a 2-sided threshold of P<0.10. Discriminatory value was determined using receiver operating characteristic analysis, area under the curve, and bootstrap validation. The final CTA carotid-source stroke prediction model included intraluminal thrombus (prevalence ratio, 2.8 [P<0.001]; 95% CI, 1.6-4.9), maximum soft plaque thickness (prevalence ratio, 1.2 [P<0.001]; 95% CI, 1.1-1.4), and the rim sign (prevalence ratio, 2.0 [P=0.007]; 95% CI, 1.2-3.3). The final discriminatory value (area under the curve=78.3%) was higher than intraluminal thrombus (56.4%, P<0.001), maximum soft plaque thickness (76.4%, P=0.007), or rim sign alone (69.9%, P=0.001). Furthermore, NASCET (North American Symptomatic Carotid Endarterectomy Trial) stenosis categories (cutoffs of 50% and 70%) had lower stroke discrimination (area under the curve=67.4%, P<0.001). Conclusions Optimal discrimination of ipsilateral carotid sources of stroke requires information on intraluminal thrombus, maximum soft plaque thickness, and the rim sign. These results argue against the sole use of carotid stenosis to determine stroke sources on CTA, and instead suggest these alternative markers may better diagnose vulnerable carotid plaque and guide treatment decisions.
Collapse
|
22
|
Capacitive versus Overlap Decoupling of Adjacent Radio Frequency Phased Array Coil Elements: An Imaging Robustness Comparison When Sample Load Varies for 3 Tesla MRI. CONCEPTS IN MAGNETIC RESONANCE. PART B, MAGNETIC RESONANCE ENGINEERING 2020; 2020:8828047. [PMID: 34867110 PMCID: PMC8640609 DOI: 10.1155/2020/8828047] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Phased array (PA) receive coils are built such that coil elements approximate independent antenna behavior. One method of achieving this goal is to use an available decoupling method to decouple adjacent coil elements. The purpose of this work was to compare the relative performance of two decoupling methods as a function of variation in sample load. Two PA receive coils with 5 channels (5-ch) each, equal outer dimensions, and formed on 12 cm diameter cylindrical phantoms of conductivities 0.3, 0.6, and 0.9 S/m were evaluated for relative signal-to-noise ratio (SNR) and parallel imaging performance. They were only tuned and matched to the 0.6 S/m phantom. Simulated and measured axial, sagittal, and coronal 5-ch PA coil SNR ratios were compared by dividing the overlap by the capacitive decoupled coil SNR results. Issues related to the selection of capacitor values for the two decoupling methods were evaluated by taking the ratio of the match and tune capacitors for large and small 2 channel (2-ch) PA coils. The SNR ratios showed that the SNR of the two decoupling methods were very similar. The inverse geometry-factor maps showed similar but better overall parallel imaging performance for the capacitive decoupled method. The quotients for the 2-ch PA coils' maximum and minimum capacitor value ratios are 3.28 and 1.38 for the large and 3.28 and 2.22 for the small PA. The results of this paper demonstrate that as the sample load varies, the capacitive and overlap decoupling methods are very similar in relative SNR and this similarity continues for parallel imaging performance. Although, for the 5-ch coils studied, the capacitive decoupling method has a slight SNR and parallel imaging advantage and it was noted that the capacitive decoupled coil is more likely to encounter unbuildable PA coil configurations.
Collapse
|
23
|
Development and characterization of a tissue mimicking psyllium husk gelatin phantom for ultrasound and magnetic resonance imaging. Int J Hyperthermia 2020; 37:283-290. [PMID: 32204632 DOI: 10.1080/02656736.2020.1739345] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
Abstract
Purpose: To develop and characterize a tissue-mimicking phantom that enables the direct comparison of magnetic resonance (MR) and ultrasound (US) imaging techniques useful for monitoring high-intensity focused ultrasound (HIFU) treatments. With no additions, gelatin phantoms produce little if any scattering required for US imaging. This study characterizes the MR and US image characteristics as a function of psyllium husk concentration, which was added to increase US scattering.Methods: Gelatin phantoms were constructed with varying concentrations of psyllium husk. The effects of psyllium husk concentration on US B-mode and MR imaging were evaluated at nine different concentrations. T1, T2, and T2* MR maps were acquired. Acoustic properties (attenuation and speed of sound) were measured at frequencies of 0.6, 1.0, 1.8, and 3.0 MHz using a through-transmission technique. Phantom elastic properties were evaluated for both time and temperature dependence.Results: Ultrasound image echogenicity increased with increasing psyllium husk concentration while quality of gradient-recalled echo MR images decreased with increasing concentration. For all phantoms, the measured speed of sound ranged between 1567-1569 m/s and the attenuation ranged between 0.42-0.44 dB/(cm·MHz). Measured T1 ranged from 974-1051 ms. The T2 and T2* values ranged from 97-108 ms and 48-88 ms, respectively, with both showing a decreasing trend with increased psyllium husk concentration. Phantom stiffness, measured using US shear-wave speed measurements, increased with age and decreased with increasing temperature.Conclusions: The presented dual-use tissue-mimicking phantom is easy to manufacture and can be used to compare and evaluate US-guided and MR-guided HIFU imaging protocols.
Collapse
|
24
|
Corrections to "The Role of Viscosity in the Impulse Diffraction Field of Elastic Waves Induced by the Acoustic Radiation Force" and "Supersonic Shear Imaging: A New Technique for Soft Tissue Elasticity Mapping". IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:1492-1494. [PMID: 32070952 PMCID: PMC7819482 DOI: 10.1109/tuffc.2020.2973565] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
This article presents corrections to J. Bercoff et al., "The role of viscosity in the impulse diffraction field of elastic waves induced by the acoustic radiation force," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 51, no. 11, pp. 1523-1536, Nov. 2004, and J. Bercoff et al., "Supersonic shear imaging: A new technique for soft tissue elasticity mapping," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 51, no. 4, pp. 396-409, Apr. 2004.
Collapse
|
25
|
Technical Note: Effect of transducer position and ground plane configuration on image quality in MR-guided focused ultrasound therapies. Med Phys 2020; 47:2350-2355. [PMID: 32170866 DOI: 10.1002/mp.14138] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2019] [Revised: 02/26/2020] [Accepted: 02/27/2020] [Indexed: 12/21/2022] Open
Abstract
PURPOSE To evaluate the effect of a focused ultrasound transducer position and ground plane configuration on magnetic resonance image quality. METHODS The effect of transducer position with respect to the MRI B0 field and the radiofrequency receive coils was evaluated in a breast-specific MRgFUS system with an integrated RF phased-array coil. Image signal-to-noise ratio was evaluated at different transducer locations. The effect of ultrasound transducer ground plane configuration was evaluated using a replica transducer with 12 ground plane configurations. All evaluations were performed at 3 Tesla. RESULTS Both transducer position and ground plane configuration were found to have a considerable effect on overall image SNR. A 67% increase in SNR was achieved by positioning the transducer face perpendicular to the B0 field. A 25% increase in SNR was achieved by segmenting the replica transducer ground plane from one continuous plane to nine individual segments. CONCLUSIONS Advances in focused ultrasound hardware allow for integrated radiofrequency MRI coils as well as adjustable transducer positioning. The placement of the ultrasound transducer with respect to both the magnetic field and RF coils can have a considerable effect on image SNR and the resulting MR images that are used for MR-guided focused ultrasound treatment planning, monitoring and assessment.
Collapse
|
26
|
Methemoglobin Modulation as an Intravascular Contrast Agent for Magnetic Resonance Imaging: Proof of Concept. Front Vet Sci 2019; 6:416. [PMID: 32039242 PMCID: PMC6988812 DOI: 10.3389/fvets.2019.00416] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2019] [Accepted: 11/07/2019] [Indexed: 11/16/2022] Open
Abstract
Objective: The aim of this feasibility study was to investigate methemoglobin modulation in vivo as a potential magnetic resonance imaging (MRI) gadolinium based contrast agent (GBCA) alternative. Recently, gadolinium tissue deposition was identified and safety concerns were raised after adverse effects were discovered in canines and humans. Because of this, alternative contrast agents are warranted. One potential alternative is methemoglobinemia induction, which can create T1-weighted signal in vitro. Canines with hereditary methemoglobinemia represent a unique opportunity to investigate methemoglobin modulation. Our objective was to determine if methemoglobinemia could create high intravascular T1-signal in vivo with reversal using methylene blue. Methods: To accomplish this study, a 1.5-year-old male-castrated mixed breed canine with hereditary methemoglobinemia underwent 3T-MRI/MRA with T1-weighted sequences including 3D-T1-weighted Magnetization Prepared Rapid Acquisition Gradient Echo (MPRAGE) and 3D-Time-Of-Flight (TOF). Images were acquired during baseline methemoglobinemia and rescued using intravenous methylene blue (1 mg/kg). Intravascular T1-signal was compared between baseline methemoglobinemia and post-methylene blue. N = 10 separate T1-signal measurements were acquired for each vascular structure, normalized to muscle. Significance was determined using paired two-tailed t-tests and threshold alpha = 0.05. Fold-change was also calculated using the ratio of T1-signal between methemoglobinemia and post-methylene blue states. Results: At baseline, methemoglobin levels measured 19.5% and decreased to 4.9% after methylene blue. On 3D-T1-weighted MPRAGE, visible signal change was present in internal vertebral venous plexus (IVVP, 1.34 ± 0.09 vs. 0.83 ± 0.05, p < 0.001, 1.62 ± 0.06-fold) and external jugular veins (1.54 ± 0.07 vs. 0.87 ± 0.06, p < 0.001, 1.78 ± 0.10-fold). There was also significant change in ventral spinal arterial signal (1.21 ± 0.11 vs. 0.79 ± 0.07, p < 0.001, 1.54 ± 0.16-fold) but not in carotid arteries (2.12 ± 0.10 vs. 2.16 ± 0.11, p = 0.07, 0.98 ± 0.03-fold). On 3D-TOF, visible signal change was in IVVP (1.64 ± 0.14 vs. 1.09 ± 0.11, p < 0.001, 1.50 ± 0.11-fold) and there was moderate change in external jugular vein signal (1.51 ± 0.13 vs. 1.19 ± 0.08, p < 0.001, 1.27 ± 0.07-fold). There were also small but significant differences in ventral spinal arterial signal (2.00 ± 0.12 vs. 1.78 ± 0.10, p = 0.002, 1.13 ± 0.10-fold) but not carotid arteries (2.03 ± 0.17 vs. 1.99 ± 0.17, p = 0.15, 1.02 ± 0.04-fold). Conclusion: Methemoglobin modulation produces intravascular contrast on T1-weighted MRI in vivo. Additional studies are warranted to optimize methemoglobinemia induction, sequence parameters for maximal tissue contrast, and safety parameters prior to clinical implementation.
Collapse
|
27
|
Magnetic Resonance Imaging and Clinical Factors Associated With Ischemic Stroke in Patients Suspected of Cervical Artery Dissection. Stroke 2019; 49:2337-2344. [PMID: 30355108 DOI: 10.1161/strokeaha.118.021868] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background and Purpose- Cervical artery dissection is a major cause of ischemic stroke in the young and presents with various imaging findings, including stenosis and intramural hematoma (IMH). Our goal was to determine the relative contribution of lumen findings and IMH to acute ischemic stroke and whether a heavily T1-weighted sequence could more reliably detect IMH. Methods- Institutional review board approval was obtained for this retrospective study of 254 patients undergoing magnetic resonance imaging/magnetic resonance angiography for suspected dissection. Imaging included standard turbo spin-echo (TSE) T1-fat saturation and heavily T1-weighted flow-suppressed magnetization-prepared rapid acquisition gradient-recalled echo sequences. Subjects with stents (1) or atherosclerotic disease (26) were excluded, leaving 227 subjects. Kappa analysis was used to determine IMH interrater reliability on magnetization-prepared rapid acquisition gradient-recalled echo and T1-fat saturation in 4 vessels per subject. Lumen findings, cardiovascular risk factors, medications, and nondissection stroke sources were recorded. Mixed-effects multivariate Poisson regression was used to determine the prevalence ratio of each factor with acute ischemic stroke, accounting for 4 vessels per patient with backward elimination to a threshold P value of 0.10. Results- Patients were 41.9% men, mean age of 47.3±16.6 years, with 114 dissections and 107 strokes. IMH interrater reliability was significantly higher for magnetization-prepared rapid acquisition gradient-recalled echo (κ=0.83; 95% CI, 0.78-0.86) versus T1-fat saturation (0.58; 95% CI, 0.57-0.68). The final acute stroke prediction model included magnetization-prepared rapid acquisition gradient-recalled echo-detected IMH (prevalence ratio, 2.0; 95% CI, 1.1-3.9; P=0.034), stenosis, pseudoaneurysm, male sex, current smoking, and nondissection stroke sources. The final model had high discrimination for acute stroke (area under the curve, 0.902; 95% CI, 0.872-0.932), compared with models without stenosis (0.861; 95% CI, 0.821-0.902), and without stenosis and IMH (0.831; 95% CI, 0.783-0.879). All 3 models were significantly different at P<0.05. Conclusions- Along with stenosis, IMH detection significantly contributed to acute ischemic stroke pathogenesis in patients with suspected cervical artery dissection. In addition, IMH detection can be made more reliable with heavily T1-weighted sequences.
Collapse
|
28
|
Effect of Time Elapsed since Gadolinium Administration on Atherosclerotic Plaque Enhancement in Clinical Vessel Wall MR Imaging Studies. AJNR Am J Neuroradiol 2019; 40:1709-1711. [PMID: 31515211 DOI: 10.3174/ajnr.a6191] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Accepted: 07/17/2019] [Indexed: 11/07/2022]
Abstract
Vessel wall MR imaging is a useful tool for the evaluation of intracranial atherosclerotic disease. Enhancement can be particularly instructive. This study investigated the impact of the duration between contrast administration and image acquisition. The cohort with the longest duration had the greatest increase in signal intensity change. When using vessel wall MR imaging to assess intracranial atherosclerotic disease, protocols should be designed to maximize the duration between contrast administration and image acquisition to best demonstrate enhancement.
Collapse
|
29
|
Efficient shear wave elastography using transient acoustic radiation force excitations and MR displacement encoding. Magn Reson Med 2019; 81:3153-3167. [PMID: 30663806 PMCID: PMC6414262 DOI: 10.1002/mrm.27647] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Revised: 11/21/2018] [Accepted: 12/05/2018] [Indexed: 12/29/2022]
Abstract
PURPOSE To present a novel MR shear wave elastography (MR-SWE) method that efficiently measures the speed of propagating wave packets generated using acoustic radiation force (ARF) impulses. METHODS ARF impulses from a focused ultrasound (FUS) transducer were applied sequentially to a preselected set of positions and motion encoded MRI was used to acquire volumetric images of the propagating shear wavefront emanating from each point. The wavefront position at multiple propagation times was encoded in the MR phase image using a train of motion encoding gradient lobes. Generating a transient propagating wavefront at multiple spatial positions and sampling each at multiple time-points allowed for shear wave speed maps to be efficiently created. MR-SWE was evaluated in tissue mimicking phantoms and ex vivo bovine liver tissue before and after ablation. RESULTS MR-SWE maps, covering an in-plane area of ~5 × 5 cm, were acquired in 12 s for a single slice and 144 s for a volumetric scan. MR-SWE detected inclusions of differing stiffness in a phantom experiment. In bovine liver, mean shear wave speed significantly increased from 1.65 ± 0.18 m/s in normal to 2.52 ± 0.18 m/s in ablated region (n = 581 pixels; P-value < 0.001). CONCLUSION MR-SWE is an elastography technique that enables precise targeting and excitation of the desired tissue of interest. MR-SWE may be particularly well suited for treatment planning and endpoint assessment of MR-guided FUS procedures because the same device used for therapy can be used as an excitation source for tissue stiffness quantification.
Collapse
|
30
|
Magnetic resonance thermometry and its biological applications - Physical principles and practical considerations. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2019; 110:34-61. [PMID: 30803693 PMCID: PMC6662927 DOI: 10.1016/j.pnmrs.2019.01.003] [Citation(s) in RCA: 66] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Accepted: 01/23/2019] [Indexed: 05/25/2023]
Abstract
Most parameters that influence the magnetic resonance imaging (MRI) signal experience a temperature dependence. The fact that MRI can be used for non-invasive measurements of temperature and temperature change deep inside the human body has been known for over 30 years. Today, MR temperature imaging is widely used to monitor and evaluate thermal therapies such as radio frequency, microwave, laser, and focused ultrasound therapy. In this paper we cover the physical principles underlying the biological applications of MR temperature imaging and discuss practical considerations and remaining challenges. For biological tissue, the MR signal of interest comes mostly from hydrogen protons of water molecules but also from protons in, e.g., adipose tissue and various metabolites. Most of the discussed methods, such as those using the proton resonance frequency (PRF) shift, T1, T2, and diffusion only measure temperature change, but measurements of absolute temperatures are also possible using spectroscopic imaging methods (taking advantage of various metabolite signals as internal references) or various types of contrast agents. Currently, the PRF method is the most used clinically due to good sensitivity, excellent linearity with temperature, and because it is largely independent of tissue type. Because the PRF method does not work in adipose tissues, T1- and T2-based methods have recently gained interest for monitoring temperature change in areas with high fat content such as the breast and abdomen. Absolute temperature measurement methods using spectroscopic imaging and contrast agents often offer too low spatial and temporal resolution for accurate monitoring of ablative thermal procedures, but have shown great promise in monitoring the slower and usually less spatially localized temperature change observed during hyperthermia procedures. Much of the current research effort for ablative procedures is aimed at providing faster measurements, larger field-of-view coverage, simultaneous monitoring in aqueous and adipose tissues, and more motion-insensitive acquisitions for better precision measurements in organs such as the heart, liver, and kidneys. For hyperthermia applications, larger coverage, motion insensitivity, and simultaneous aqueous and adipose monitoring are also important, but great effort is also aimed at solving the problem of long-term field drift which gets interpreted as temperature change when using the PRF method.
Collapse
|
31
|
Assessment of quantitative methods for enhancement measurement on vessel wall magnetic resonance imaging evaluation of intracranial atherosclerosis. Neuroradiology 2019; 61:643-650. [PMID: 30675639 DOI: 10.1007/s00234-019-02167-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Accepted: 01/11/2019] [Indexed: 11/29/2022]
Abstract
PURPOSE Quantitative measures of vessel wall magnetic resonance imaging (vwMRI) for the evaluation of intracranial atherosclerotic disease (ICAD) offers standardization not available with previously used qualitative approaches that may be difficult to replicate. METHODS vwMRI studies performed to evaluate ICAD that had caused a stroke were analyzed. Two blinded reviewers qualitatively rated culprit lesions for the presence of enhancement on T1 delay alternating with nutation for tailored excitation (DANTE) SPACE images. At least 3 months later, quantitative analysis was performed of the same images, comparing lesion enhancement to reference structures. Cohen's kappa and intraclass correlation coefficients were calculated to assess agreement. Ratios of enhancement of lesions to references were compared to qualitative ratings. RESULTS Studies from 54 patients met inclusion criteria. A mean of 49 (90.7%) lesions were qualitatively rated as enhancing, with good inter-rater agreement (κ = 0.783). Among reference structure candidates, low infundibulum demonstrated the highest inter-rater agreement on pre- and post-contrast imaging. The ratio of percentage increase in plaque signal following contrast to the same measure in low infundibulum demonstrated the highest agreement with qualitative assessment, with highest agreement seen with a ratio of 0.8 set as a threshold (κ = 0.675). CONCLUSION Quantitative metrics can yield objective data to better standardize techniques and acceptance of vwMRI evaluation of ICAD. The low infundibulum had the highest inter-rater agreement on both pre- and post-contrast images and is best suited as a normally enhancing reference structure. Such quantitative techniques should be implemented in future research of vwMRI for the evaluation of ICAD.
Collapse
|
32
|
Simultaneous proton resonance frequency shift thermometry and T 1 measurements using a single reference variable flip angle T 1 method. Magn Reson Med 2019; 81:3138-3152. [PMID: 30652347 DOI: 10.1002/mrm.27643] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Revised: 11/20/2018] [Accepted: 11/29/2018] [Indexed: 12/31/2022]
Abstract
PURPOSE Implement simultaneous proton resonance frequency (PRF) shift and T1 measurements with equivalent temporal resolution using a single reference variable flip angle method. This novel method allows for simultaneous thermometry in both aqueous and fatty tissue. METHODS This method acquires a single reference image at the lower flip angle and all dynamic images at the higher angle. T1 is calculated using a single reference variable flip angle method, which accounts for the reference image temperature remaining constant. Monte Carlo simulations determined the optimal dynamic flip angle for combined PRF and T1 measurements. This method was evaluated in MR-guided focused ultrasound heating experiments using a gelatin phantom and human cadaver breasts. In vivo measurement precision was demonstrated in healthy female volunteers under nonheating conditions. RESULTS Temperature rise during MR-guided focused ultrasound heating was measured in aqueous tissue with both PRF and T1 . Both measures show good qualitative agreement in both space and time in aqueous tissue. The T1 change due to temperature increase was measured in fat, demonstrating the expected temporal response. The dynamic flip angle that produces optimal SNR for PRF measurements is lower than the optimal angle for T1 measurements, necessitating the selection of a compromise angle. CONCLUSION The single reference variable flip angle method provides a reliable way to simultaneously measure PRF temperature and T1 change and overcomes PRF's inability to simultaneously monitor temperature in aqueous and adipose tissues. Future work will calibrate T1 change to temperature, enabling real-time temperature in fat and increasing patient safety and treatment efficacy during thermal interventional treatments.
Collapse
|
33
|
Improved MR thermometry for laser interstitial thermotherapy. Lasers Surg Med 2019; 51:286-300. [PMID: 30645017 DOI: 10.1002/lsm.23049] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/28/2018] [Indexed: 12/24/2022]
Abstract
OBJECTIVES To develop, test and evaluate improved 2D and 3D protocols for proton resonance frequency shift magnetic resonance temperature imaging (MRTI) of laser interstitial thermal therapy (LITT). The objective was to develop improved MRTI protocols in terms of temperature measurement precision and volume coverage compared to the 2D MRTI protocol currently used with a commercially available LITT system. METHODS Four different 2D protocols and four different 3D protocols were investigated. The 2D protocols used multi-echo readouts to prolong the total MR sampling time and hence the MRTI precision, without prolonging the total acquisition time. The 3D protocols provided volumetric thermometry by acquiring a slab of 12 contiguous slices in the same acquisition time as the 2D protocols. The study only considered readily available pulse sequences (Cartesian 2D and 3D gradient recalled echo and echo planar imaging [EPI]) and methods (partial Fourier and parallel imaging) to ensure wide availability and rapid clinical implementation across vendors and field strengths. In vivo volunteer studies were performed to investigate and compare MRTI precision and image quality. Phantom experiments with LITT heating were performed to investigate and compare MRTI precision and accuracy. Different coil setups were used in the in vivo studies to assess precision differences between using local (such as flex and head coils) and non-local (i.e., body coil) receive coils. Studies were performed at both 1.5 T and 3 T. RESULTS The improved 2D protocols provide up to a factor of two improvement in the MRTI precision in the same acquisition time, compared to the currently used clinical protocol. The 3D echo planar imaging protocols provide comparable precision as the currently used 2D clinical protocol, but over a substantially larger field of view, without increasing the acquisition time. As expected, local receive coils perform substantially better than the body coil, and 3 T provides better MRTI accuracy and precision than 1.5 T. 3D data can be zero-filled interpolated in all three dimensions (as opposed to just two dimensions for 2D data), reducing partial volume effects and measuring higher maximum temperature rises. CONCLUSIONS With the presented protocols substantially improved MRTI precision (for 2D imaging) or greatly improved field of view coverage (for 3D imaging) can be achieved in the same acquisition time as the currently used protocol. Only widely available pulse sequences and acquisition methods were investigated, which should ensure quick translation to the clinic. Lasers Surg. Med. 51:286-300, 2019. © 2019 Wiley Periodicals, Inc.
Collapse
|
34
|
Multiple-point magnetic resonance acoustic radiation force imaging. Magn Reson Med 2018; 81:1104-1117. [PMID: 30257059 PMCID: PMC6642829 DOI: 10.1002/mrm.27477] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Revised: 07/09/2018] [Accepted: 07/11/2018] [Indexed: 12/13/2022]
Abstract
PURPOSE To implement and evaluate an efficient multiple-point MR acoustic radiation force imaging pulse sequence that can volumetrically measure tissue displacement and evaluate tissue stiffness using focused ultrasound (FUS) radiation force. METHODS Bipolar motion-encoding gradients were added to a gradient-recalled echo segmented EPI pulse sequence with both 2D and 3D acquisition modes. Multiple FUS-ON images (FUS power > 0 W) were interleaved with a single FUS-OFF image (FUS power = 0 W) on the TR level, enabling simultaneous measurements of volumetric tissue displacement (by complex subtraction of the FUS-OFF image from the FUS-ON images) and proton resonance frequency shift MR thermometry (from the OFF image). Efficiency improvements included partial Fourier acquisition, parallel imaging, and encoding up to 4 different displacement positions into a single image. Experiments were performed in homogenous and dual-stiffness phantoms, and in ex vivo porcine brain. RESULTS In phantoms, 16-point multiple-point magnetic resonance acoustic radiation force imaging maps could be acquired in 5 s to 10 s for a 2D slice, and 60 s for a 3D volume, using parallel imaging and encoding 2 displacement positions/image. In ex vivo porcine brain, 16-point multiple-point magnetic resonance acoustic radiation force imaging maps could be acquired in 20 s for a 3D volume, using partial Fourier and parallel imaging and encoding 4 displacement positions/image. In 1 experiment it was observed that tissue displacement in ex vivo brain decreased by approximately 22% following FUS ablation. CONCLUSION With the described efficiency improvements it is possible to acquire volumetric multiple-point magnetic resonance acoustic radiation force imaging maps, with simultaneous proton resonance frequency shift MR thermometry maps, in clinically acceptable times.
Collapse
|
35
|
Effect of k-space-weighted image contrast and ultrasound focus size on the accuracy of proton resonance frequency thermometry. Magn Reson Med 2018; 81:247-257. [PMID: 30058224 DOI: 10.1002/mrm.27383] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 05/07/2018] [Accepted: 05/08/2018] [Indexed: 12/30/2022]
Abstract
PURPOSE To construct a predictive model that describes how the duration and symmetry of a k-space-weighted image contrast (KWIC) window affects the temporal resolution of differently sized ultrasound foci when using a pseudo-golden angle stack-of-stars acquisition. METHODS We performed a modulation analysis of proton resonance frequency temperature measurements to create the temporal modulation transfer function for KWIC windows of different symmetry and temporal duration. We reconstructed simulated ultrasound heating trajectories and stack-of-stars k-space data as well as experimental phantom data using the same trajectories. Images were reconstructed using symmetric and asymmetric KWIC windows of 3 different temporal durations. Simulated results were compared against temporal modulation transfer function predictions, experimental results, and the original simulated temperatures. RESULTS The temporal modulation transfer function shows that temporal resolution with KWIC reconstructions depend on the object size. The KWIC window duration affected SNR and severity of undersampling artifacts. Accuracy and response delay improved as the KWIC window duration decreased or the size of the heated region within the KWIC plane increased. Precision worsened as the window duration decreased. Using a symmetric window eliminated the response delay to heated region size but introduced a large reconstruction delay. CONCLUSION The accuracy and precision of proton resonance frequency temperature measurements from a stack-of-stars acquisition using a sliding KWIC window reconstruction are dependent on the size of the KWIC window and the size and shape of the heated region. The temporal modulation transfer function of KWIC reconstructions for any object size can predict the temporal response to changes in signal being acquired, such as temperature and contrast enhancement.
Collapse
|
36
|
3D-specific absorption rate estimation from high-intensity focused ultrasound sonications using the Green's function heat kernel. Med Phys 2018; 45:3109-3119. [PMID: 29772066 DOI: 10.1002/mp.12978] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2017] [Revised: 03/12/2018] [Accepted: 04/19/2018] [Indexed: 11/12/2022] Open
Abstract
PURPOSE To evaluate a numerical inverse Green's function method for deriving specific absorption rates (SARs) from high-intensity focused ultrasound (HIFU) sonications using tissue parameters (thermal conductivity, specific heat capacity, and mass density) and three-dimensional (3D) magnetic resonance imaging (MRI) temperature measurements. METHODS SAR estimates were evaluated using simulations and MR temperature measurements from HIFU sonications. For simulations, a "true" SAR was calculated using the hybrid angular spectrum method for ultrasound simulations. This "true" SAR was plugged into a Pennes bioheat transfer equation (PBTE) solver to provide simulated temperature maps, which were then used to calculate the SAR estimate using the presented method. Zero mean Gaussian noise, corresponding to temperature precisions between 0.1 and 2.0°C, was added to the temperature maps to simulate a variety of in vivo situations. Experimental MR temperature maps from HIFU sonications in a gelatin phantom monitored with a 3D segmented echo planar imaging MRI pulse sequence were also used. To determine the accuracy of the simulated and phantom data, we reconstructed temperature maps by plugging in the estimated SAR to the PBTE solver. In both simulations and phantom experiments, the presented method was compared to two previously published methods of determining SAR, a linear and an analytical method. The presented numerical method utilized the full 3D data simultaneously, while the two previously published methods work on a slice-by-slice basis. RESULTS In the absence of noise, SAR distribution estimates obtained from the simulated heating profiles match closely (within 10%) to the initial true SAR distribution. The resulting temperature distributions also match closely to the corresponding initial temperature distributions (<0.2°C RMSE). In the presence of temperature measurement noise, the SAR distributions have noise amplified by the inverse convolution process, while the resulting temperature distributions still match closely to the initial "true" temperature distributions. In general, temperature RMSE was observed to be approximately 20-30% higher than the level of the added noise. By contrast, the previously published linear method is less sensitive to noise, but significantly underpredicts the SAR. The analytic method is also less sensitive to noise and matches SAR in the central plane, but greatly underpredicts in the longitudinal direction. Similar observations are made from the phantom studies. The described numerical inverse Green's function method is very fast - at least two orders of magnitude faster than the compared methods. CONCLUSION The presented numerical inverse Green's function method is computationally fast and generates temperature maps with high accuracy. This is true despite generally overestimating the true SAR and amplifying the input noise.
Collapse
|
37
|
Technical Note: The effect of 2D excitation profile on T1 measurement accuracy using the variable flip angle method with an average flip angle assumption. Med Phys 2017; 44:5930-5937. [PMID: 28796308 DOI: 10.1002/mp.12513] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Revised: 07/26/2017] [Accepted: 07/26/2017] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To study the accuracy and precision of T1 estimates using the Variable Flip Angle (VFA) method in 2D and 3D acquisitions. METHODS Excitation profiles were simulated using numerical implementation of the Bloch equations for Hamming-windowed sinc excitation pulses with different time-bandwidth products (TBP) of 2, 6, and 10 and for T1 values of 295 ms and 1045 ms. Experimental data were collected in 5° increments from 5° to 90° for the same T1 and TBP values. T1 was calculated for every combination of flip angle with and without a correction for B1 and slice profile variation. Calculations were also made for flat slice profile such as obtained in 3D acquisition. Monte Carlo simulations were performed to obtain T1 measurement uncertainty. RESULTS VFA T1 measurements in 2D without correction can result in a 40-80% underestimation of true T1 . Flip angle correction can reduce the underestimation, but results in accurate measurements of T1 only within a narrow band of flip angle combinations. The narrow band of accuracy increases with TBP, but remains too narrow for any practical range of T1 values or B1 variation. Simulated noisy VFA T1 measurements in 3D were accurate as long as the two angles chosen are on either side of the Ernst angle. CONCLUSIONS Accurate T1 estimates from VFA 2D acquisitions are possible, but only a narrow range of T1 values within a narrow range of flip angle combinations can be accurately calculated using a 2D slice. Unless a better flip angle correction method is used, these results demonstrate that accurate measurements of T1 in 2D cannot be obtained robustly enough for practical use and are more likely obtained by a thin slab 3D VFA acquisition than from multiple-slice 2D acquisitions. VFA T1 measurements in 3D are accurate for wide ranges of flip angle combinations and T1 values.
Collapse
|
38
|
Simultaneous MR thermometry and acoustic radiation force imaging using interleaved acquisition. Magn Reson Med 2017; 79:1515-1524. [PMID: 28795419 DOI: 10.1002/mrm.26827] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2017] [Revised: 05/15/2017] [Accepted: 06/15/2017] [Indexed: 12/25/2022]
Abstract
PURPOSE A novel and practical method for simultaneously performing MR acoustic radiation force imaging (ARFI) and proton resonance frequency (PRF)-shift thermometry has been developed and tested. This could be an important tool for evaluating the success of MR-guided focused ultrasound procedures for which MR-thermometry measures temperature and thermal dose and MR-ARFI detects changes in tissue mechanical properties. METHODS MR imaging was performed using a gradient recalled echo segmented echo-planar imaging pulse sequence with bipolar motion encoding gradients (MEG). Images with ultrasound pulses (ON) and without ultrasound pulses (OFF) during the MEG were interleaved at the repetition time (TR) level. ARFI displacements were calculated by complex subtraction of ON-OFF images, and PRF temperature maps were calculated by baseline subtraction. Evaluations in tissue-mimicking phantoms and ex vivo porcine brain tissue were performed. Constrained reconstruction improved the temporal resolution of dynamic measurements. RESULTS Simultaneous maps of displacement and temperature were acquired in 2D and 3D while keeping tissue heating < 1°C. Accuracy of the temperature maps was comparable to the standard PRF sequence. Using constrained reconstruction and subsampled k-space (R = 4.33), 3D simultaneous temperature and displacement maps can be acquired every 4.7 s. CONCLUSION This new sequence acquires simultaneous temperature and displacement maps with minimal tissue heating, and can be applied dynamically for monitoring tissue mechanical properties during ablation procedures. Magn Reson Med 79:1515-1524, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
|
39
|
Multiecho pseudo-golden angle stack of stars thermometry with high spatial and temporal resolution using k-space weighted image contrast. Magn Reson Med 2017. [PMID: 28643383 DOI: 10.1002/mrm.26797] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
PURPOSE Implement and evaluate a 3D MRI method to measure temperature changes with high spatial and temporal resolution and large field of view. METHODS A multiecho pseudo-golden angle stack-of-stars (SOS) sequence with k-space weighted image contrast (KWIC) reconstruction was implemented to simultaneously measure multiple quantities, including temperature, initial signal magnitude M(0), transverse relaxation time ( T2*), and water/fat images. Respiration artifacts were corrected using self-navigation. KWIC artifacts were removed using a multi-baseline library. The phases of the multiple echo images were combined to improve proton resonance frequency precision. Temperature precision was tested through in vivo breast imaging (N = 5 healthy volunteers) using both coronal and sagittal orientations and with focused ultrasound (FUS) heating in a pork phantom using a breast specific MR-guided FUS system. RESULTS Temperature measurement precision was significantly improved after echo combination when compared with the no echo combination case (spatial average of the standard deviation through time of 0.3-1.0 and 0.7-1.9°C, respectively). Temperature measurement accuracy during heating was comparable to a 3D seg-EPI sequence. M(0) and T2* values showed temperature dependence during heating in pork adipose tissue. CONCLUSION A self-navigated 3D multiecho SOS sequence with dynamic KWIC reconstruction is a promising thermometry method that provides multiple temperature sensitive quantitative values. Magn Reson Med 79:1407-1419, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
|
40
|
Low-intensity ultrasound activates vestibular otolith organs through acoustic radiation force. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 141:4209. [PMID: 28618821 PMCID: PMC5552392 DOI: 10.1121/1.4984287] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2017] [Revised: 05/11/2017] [Accepted: 05/15/2017] [Indexed: 06/03/2023]
Abstract
The present study examined the efficacy of 5 MHz low-intensity focused ultrasound (LiFU) as a stimulus to remotely activate inner ear vestibular otolith organs. The otolith organs are the primary sensory apparati responsible for detecting orientation of the head relative to gravity and linear acceleration in three-dimensional space. These organs also respond to loud sounds and vibration of the temporal bone. The oyster toadfish, Opsanus tau, was used to facilitate unobstructed acoustic access to the otolith organs in vivo. Single-unit responses to amplitude-modulated LiFU were recorded in afferent neurons identified as innervating the utricle or the saccule. Neural responses were equivalent to direct mechanical stimulation, and arose from the nonlinear acoustic radiation force acting on the otolithic mass. The magnitude of the acoustic radiation force acting on the otolith was measured ex vivo. Results demonstrate that LiFU stimuli can be tuned to mimic directional forces occurring naturally during physiological movements of the head, loud air conducted sound, or bone conducted vibration.
Collapse
|
41
|
|
42
|
Magnetic Resonance Imaging Detection of Intraplaque Hemorrhage. MAGNETIC RESONANCE INSIGHTS 2017; 10:1-8. [PMID: 28469441 PMCID: PMC5348123 DOI: 10.1177/1178623x17694150] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2016] [Accepted: 01/25/2017] [Indexed: 11/16/2022]
Abstract
Carotid artery atherosclerosis is a major cause of ischemic stroke. For more than 30 years, future stroke risk and carotid stroke etiology have been determined using percent diameter stenosis based on clinical trials in the 1990s. In the past 10 years, magnetic resonance imaging (MRI) sequences have been developed to detect carotid intraplaque hemorrhage. By detecting carotid intraplaque hemorrhage, MRI identifies potential stroke sources that are often overlooked by lumen imaging. In addition, MRI can dramatically improve assessment of future stroke risk beyond lumen stenosis alone. In this review, we discuss the use of heavily T1-weighted MRI sequences used to detect carotid intraplaque hemorrhage. In addition, advances in ciné imaging, motion robust techniques, and specialized neck coils will be reviewed. Finally, the clinical use and future impact of MRI plaque hemorrhage imaging will be discussed.
Collapse
|
43
|
Interchangeable neck shape-specific coils for a clinically realizable anterior neck phased array system. Magn Reson Med 2017; 78:2460-2468. [PMID: 28185303 DOI: 10.1002/mrm.26632] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2016] [Revised: 12/22/2016] [Accepted: 01/11/2017] [Indexed: 11/08/2022]
Abstract
PURPOSE To demonstrate the interchangeable neck shape-specific (NSS) coil concept that supplements standard commercial spine and head/neck coils to provide simultaneous high-resolution (hi-res) head/neck imaging with high signal-to-noise ratio (SNR). METHODS Two NSS coils were constructed on formers designed to fit two different neck shapes. A 7-channel (7ch) ladder array was constructed on a medium neck former, and a 9-channel (9ch) ladder array was constructed on large neck former. Both coils were interchangeable with the same preamp housing. RESULTS The 7ch and 9ch coils demonstrate SNR gains of approximately 4 times and 3 times over the Siemens 20-channel head/neck coil in the carotid arteries of our volunteers, respectively. Coupling between the Siemens 32-channel spine coil, Siemens 20-channel head/neck coil, and the NSS coils was negligible, allowing for simultaneous hi-res head/neck imaging with high SNR. CONCLUSIONS This study demonstrates that supplementing existing commercial spine and head/neck coils with an NSS coil allows uniform simultaneous hi-res imaging with high SNR in the anterior neck, while maintaining SNR of the commercial coil in the head and posterior neck. Magn Reson Med 78:2460-2468, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
|
44
|
MR thermometry for focused ultrasound monitoring utilizing model predictive filtering and ultrasound beam modeling. J Ther Ultrasound 2016; 4:23. [PMID: 27688881 PMCID: PMC5032243 DOI: 10.1186/s40349-016-0067-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2016] [Accepted: 09/02/2016] [Indexed: 12/28/2022] Open
Abstract
Background A major challenge in using magnetic resonance temperature imaging (MRTI) to monitor focused ultrasound (FUS) applications is achieving high spatio-temporal resolution over a large field of view (FOV). This is important to accurately monitor all ultrasound (US) power depositions. Magnetic resonance (MR) subsampling in conjunction with thermal model-based reconstruction of the MRTI utilizing Pennes bioheat transfer equation (PBTE) is one promising approach. The thermal properties used in the thermal model are often estimated from a pre-treatment, low-power sonication. Methods In this proof-of-concept study we investigate the use of US simulations computed using the hybrid angular spectrum (HAS) method to estimate the US power deposition density Q, thereby avoiding the pre-treatment sonication and any potential tissue damage. MRTI reconstructions are performed using a thermal model-based reconstruction method called model predictive filtering (MPF). Experiments are performed in a homogeneous gelatin phantom and in a gelatin phantom with embedded plastic skull. MPF reconstructions are compared to separate sonications imaged with fully sampled data over a smaller FOV. Temperature root-mean-square errors (RMSE) and focal spot positions and shapes are evaluated. Results HAS simulations accurately predict the location of the focal spot (to within 1 mm) in both phantoms. Accurate temperature maps (RMSE below 1 °C), where the location of the focal spot agrees well with fully sampled “truth” (to within 1 mm), are also achieved in both phantoms. Conclusions HAS simulations can be used to accurately predict the focal spot location in homogeneous media and when focusing through an aberrating plastic skull. The HAS simulated power deposition (Q) patterns can be used in the MPF thermal model-based reconstruction to obtain accurate temperature maps with high spatio-temporal resolution over large FOVs.
Collapse
|
45
|
Sensitivity of tissue properties derived from MRgFUS temperature data to input errors and data inclusion criteria: ex vivo study in porcine muscle. Phys Med Biol 2016; 61:N373-85. [PMID: 27385508 DOI: 10.1088/0031-9155/61/15/n373] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
This study evaluates the sensitivity of two magnetic resonance-guided focused ultrasound (MRgFUS) thermal property estimation methods to errors in required inputs and different data inclusion criteria. Using ex vivo pork muscle MRgFUS data, sensitivities to required inputs are determined by introducing errors to ultrasound beam locations (r error = -2 to 2 mm) and time vectors (t error = -2.2 to 2.2 s). In addition, the sensitivity to user-defined data inclusion criteria is evaluated by choosing different spatial (r fit = 1-10 mm) and temporal (t fit = 8.8-61.6 s) regions for fitting. Beam location errors resulted in up to 50% change in property estimates with local minima occurring at r error = 0 and estimate errors less than 10% when r error < 0.5 mm. Errors in the time vector led to property estimate errors up to 40% and without local minimum, indicating the need to trigger ultrasound sonications with the MR image acquisition. Regarding the selection of data inclusion criteria, property estimates reached stable values (less than 5% change) when r fit > 2.5 × FWHM, and were most accurate with the least variability for longer t fit. Guidelines provided by this study highlight the importance of identifying required inputs and choosing appropriate data inclusion criteria for robust and accurate thermal property estimation. Applying these guidelines will prevent the introduction of biases and avoidable errors when utilizing these property estimation techniques for MRgFUS thermal modeling applications.
Collapse
|
46
|
Prediction of Carotid Intraplaque Hemorrhage Using Adventitial Calcification and Plaque Thickness on CTA. AJNR Am J Neuroradiol 2016; 37:1496-503. [PMID: 27102316 DOI: 10.3174/ajnr.a4765] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2015] [Accepted: 01/28/2016] [Indexed: 12/21/2022]
Abstract
BACKGROUND AND PURPOSE Carotid intraplaque hemorrhage is associated with stroke, plaque thickness, stenosis, ulceration, and adventitial inflammation. Conflicting data exist on whether calcification is a marker of plaque instability, and no data exist on adventitial calcification. Our goal was to determine whether adventitial calcification and soft plaque (a rim sign) help predict carotid intraplaque hemorrhage. MATERIALS AND METHODS This was a retrospective cohort study of 96 patients who underwent carotid MRA and CTA within 1 month, from 2009 to 2016. We excluded occlusions (n = 4) and near occlusions (n = 0), leaving 188 carotid arteries. Intraplaque hemorrhage was detected by using MPRAGE. Calcification, adventitial pattern, stenosis, maximum plaque thickness (total, soft, and hard), ulceration, and intraluminal thrombus on CTA were recorded. Atherosclerosis risk factors and medications were recorded. We used mixed-effects multivariable Poisson regression, accounting for 2 vessels per patient. For the final model, backward elimination was used with a threshold of P < .10. Receiver operating characteristic analysis determined intraplaque hemorrhage by using the area under the curve. RESULTS Our final model included the rim sign (prevalence ratio = 11.9, P < .001) and maximum soft-plaque thickness (prevalence ratio = 1.2, P = .06). This model had excellent intraplaque hemorrhage prediction (area under the curve = 0.94), outperforming the rim sign, maximum soft-plaque thickness, NASCET stenosis, and ulceration (area under the curve = 0.88, 0.86, 0.77, and 0.63, respectively; P < .001). Addition of the rim sign performed better than each marker alone, including maximum soft-plaque thickness (area under the curve = 0.94 versus 0.86, P < .001), NASCET stenosis (area under the curve = 0.90 versus 0.77, P < .001), and ulceration (area under the curve = 0.90 versus 0.63, P < .001). CONCLUSIONS The CTA rim sign of adventitial calcification with internal soft plaque is highly predictive of carotid intraplaque hemorrhage.
Collapse
|
47
|
Focal point determination in magnetic resonance-guided focused ultrasound using tracking coils. Magn Reson Med 2016; 77:2424-2430. [PMID: 27418429 DOI: 10.1002/mrm.26294] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2016] [Revised: 05/07/2016] [Accepted: 05/11/2016] [Indexed: 11/08/2022]
Abstract
PURPOSE To develop a method for rapid prediction of the geometric focus location in MR coordinates of a focused ultrasound (US) transducer with arbitrary position and orientation without sonicating. METHODS Three small tracker coil circuits were designed, constructed, attached to the transducer housing of a breast-specific MR-guided focused US (MRgFUS) system with 5 degrees of freedom, and connected to receiver channel inputs of an MRI scanner. A one-dimensional sequence applied in three orthogonal directions determined the position of each tracker, which was then corrected for gradient nonlinearity. In a calibration step, low-level heating located the US focus in one transducer position orientation where the tracker positions were also known. Subsequent US focus locations were determined from the isometric transformation of the trackers. The accuracy of this method was verified by comparing the tracking coil predictions to thermal center of mass calculated using MR thermometry data acquired at 16 different transducer positions for MRgFUS sonications in a homogeneous gelatin phantom. RESULTS The tracker coil predicted focus was an average distance of 2.1 ± 1.1 mm from the thermal center of mass. The one-dimensional locator sequence and prediction calculations took less than 1 s to perform. CONCLUSION This technique accurately predicts the geometric focus for a transducer with arbitrary position and orientation without sonicating. Magn Reson Med 77:2424-2430, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
|
48
|
Motion-insensitive carotid intraplaque hemorrhage imaging using 3D inversion recovery preparation stack of stars (IR-prep SOS) technique. J Magn Reson Imaging 2016; 45:410-417. [PMID: 27383756 DOI: 10.1002/jmri.25365] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2016] [Accepted: 06/15/2016] [Indexed: 11/11/2022] Open
Abstract
PURPOSE Carotid artery imaging is important in the clinical management of patients at risk for stroke. Carotid intraplaque hemorrhage (IPH) presents an important diagnostic challenge. 3D magnetization prepared rapid acquisition gradient echo (MPRAGE) has been shown to accurately image carotid IPH; however, this sequence can be limited due to motion- and flow-related artifact. The purpose of this work was to develop and evaluate an improved 3D carotid MPRAGE sequence for IPH detection. We hypothesized that a radial-based k-space trajectory sequence such as "Stack of Stars" (SOS) incorporated with inversion recovery preparation would offer reduced motion sensitivity and more robust flow suppression by oversampling of central k-space. MATERIALS AND METHODS A total of 31 patients with carotid disease (62 carotid arteries) were imaged at 3T magnetic resonance imaging (MRI) with 3D IR-prep Cartesian and SOS sequences. Image quality was determined between SOS and Cartesian MPRAGE in 62 carotid arteries using t-tests and multivariable linear regression. Kappa analysis was used to determine interrater reliability. RESULTS In all, 25 among 62 carotid plaques had carotid IPH by consensus from the reviewers on SOS compared to 24 on Cartesian sequence. Image quality was significantly higher with SOS compared to Cartesian (mean 3.74 vs. 3.11, P < 0.001). SOS acquisition yielded sharper image features with less motion (19.4% vs. 45.2%, P < 0.002) and flow artifact (27.4% vs. 41.9%, P < 0.089). There was also excellent interrater reliability with SOS (kappa = 0.89), higher than that of Cartesian (kappa = 0.84). CONCLUSION By minimizing flow and motion artifacts and retaining high interrater reliability, the SOS MPRAGE has important advantages over Cartesian MPRAGE in carotid IPH detection. LEVEL OF EVIDENCE 1 J. Magn. Reson. Imaging 2017;45:410-417.
Collapse
|
49
|
Vitamin D and Vulnerable Carotid Plaque. AJNR Am J Neuroradiol 2016; 37:2092-2099. [PMID: 27313129 DOI: 10.3174/ajnr.a4849] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2015] [Accepted: 04/26/2016] [Indexed: 12/18/2022]
Abstract
BACKGROUND AND PURPOSE MR imaging-detected carotid intraplaque hemorrhage indicates vulnerable plaque with high stroke risk. Angiotensin II stimulates intraplaque hemorrhage in animal models, and the angiotensin system is highly regulated by vitamin D. Our purpose was to determine whether low vitamin D levels predict carotid intraplaque hemorrhage in humans. MATERIALS AND METHODS In this cross-sectional study, 65 patients with carotid disease underwent carotid MR imaging and blood draw. Systemic clinical confounders and local lumen imaging markers were recorded. To determine the association of low vitamin D levels with MR imaging detected intraplaque hemorrhage, we performed multivariable Poisson regression by using generalized estimating equations to account for up to 2 carotid arteries per patient and backward elimination of confounders. MR imaging detected intraplaque hemorrhage volume was also correlated with vitamin D levels and maximum plaque thickness. Thirty-five patients underwent carotid endarterectomy, and histology-detected intraplaque hemorrhage was correlated with vitamin D levels and total plaque area. RESULTS Low vitamin D levels (<30 ng/mL, prevalence ratio = 2.05, P = .03) were a significant predictor of MR imaging detected intraplaque hemorrhage, along with plaque thickness (prevalence ratio = 1.40, P < .001). MR imaging detected intraplaque hemorrhage volume linearly correlated with plaque thickness (partial r = 0.45, P < .001) and low vitamin D levels (partial r = 0.26, P = .003). Additionally, histology-detected intraplaque hemorrhage area linearly correlated with plaque area (partial r = 0.46, P < .001) and low vitamin D levels (partial r = 0.22, P = .03). The association of intraplaque hemorrhage volume with low vitamin D levels was also higher with ischemic stroke. CONCLUSIONS Low vitamin D levels and plaque thickness predict carotid intraplaque hemorrhage and outperform lumen markers of vulnerable plaque. This research demonstrates a significant link between low vitamin D levels and carotid intraplaque hemorrhage.
Collapse
|
50
|
Phase aberration simulation study of MRgFUS breast treatments. Med Phys 2016; 43:1374-84. [PMID: 26936722 PMCID: PMC4769272 DOI: 10.1118/1.4941013] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2015] [Revised: 01/11/2016] [Accepted: 01/18/2016] [Indexed: 01/24/2023] Open
Abstract
PURPOSE This simulation study evaluates the effects of phase aberration in breast MR-guided focused ultrasound (MRgFUS) ablation treatments performed with a phased-array transducer positioned laterally to the breast. A quantification of these effects in terms of thermal dose delivery and the potential benefits of phase correction is demonstrated in four heterogeneous breast numerical models. METHODS To evaluate the effects of varying breast tissue properties on the quality of the focus, four female volunteers with confirmed benign fibroadenomas were imaged using 3T MRI. These images were segmented into numerical models with six tissue types, with each tissue type assigned standard acoustic properties from the literature. Simulations for a single-plane 16-point raster-scan treatment trajectory centered in a fibroadenoma in each modeled breast were performed for a breast-specific MRgFUS system. At each of the 16 points, pressure patterns both with and without applying a phase correction technique were determined with the hybrid-angular spectrum method. Corrected phase patterns were obtained using a simulation-based phase aberration correction technique to adjust each element's transmit phase to obtain maximized constructive interference at the desired focus. Thermal simulations were performed for both the corrected and uncorrected pressure patterns using a finite-difference implementation of the Pennes bioheat equation. The effect of phase correction was evaluated through comparison of thermal dose accumulation both within and outside a defined treatment volume. Treatment results using corrected and uncorrected phase aberration simulations were compared by evaluating the power required to achieve a 20 °C temperature rise at the first treatment location. The extent of the volumes that received a minimum thermal dose of 240 CEM at 43 °C inside the intended treatment volume as well as the volume in the remaining breast tissues was also evaluated in the form of a dose volume ratio (DVR), a DVR percent change between corrected and uncorrected phases, and an additional metric that measured phase spread. RESULTS With phase aberration correction applied, there was an improvement in the focus for all breast anatomies as quantified by a reduction in power required (13%-102%) to reach 20 °C when compared to uncorrected simulations. Also, the DVR percent change increased by 5%-77% in seven out of eight cases, indicating an improvement to the treatment as measured by a reduction in thermal dose deposited to the nontreatment tissues. Breast compositions with a higher degree of heterogeneity along the ultrasound beam path showed greater reductions in thermal dose delivered outside of the treatment volume with correction applied than beam trajectories that propagated through more homogeneous breast compositions. An increasing linear trend was observed between the DVR percent change and the phase-spread metric (R(2) = 0.68). CONCLUSIONS These results indicate that performing phase aberration correction for breast MRgFUS treatments is beneficial for the small-aperture transducer (14.4 × 9.8 cm) evaluated in this work. While all breast anatomies could benefit from phase aberration correction, greater benefits are observed in more heterogeneous anatomies.
Collapse
|