1
|
GRASP reconstruction amplified with view-sharing and KWIC filtering reduces underestimation of peak velocity in highly-accelerated real-time phase-contrast MRI: A preliminary evaluation in pediatric patients with congenital heart disease. Magn Reson Med 2024; 91:1965-1977. [PMID: 38084397 PMCID: PMC10950531 DOI: 10.1002/mrm.29974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 10/27/2023] [Accepted: 11/27/2023] [Indexed: 02/01/2024]
Abstract
PURPOSE To develop a highly-accelerated, real-time phase contrast (rtPC) MRI pulse sequence with 40 fps frame rate (25 ms effective temporal resolution). METHODS Highly-accelerated golden-angle radial sparse parallel (GRASP) with over regularization may result in temporal blurring, which in turn causes underestimation of peak velocity. Thus, we amplified GRASP performance by synergistically combining view-sharing (VS) and k-space weighted image contrast (KWIC) filtering. In 17 pediatric patients with congenital heart disease (CHD), the conventional GRASP and the proposed GRASP amplified by VS and KWIC (or GRASP + VS + KWIC) reconstruction for rtPC MRI were compared with respect to clinical standard PC MRI in measuring hemodynamic parameters (peak velocity, forward volume, backward volume, regurgitant fraction) at four locations (aortic valve, pulmonary valve, left and right pulmonary arteries). RESULTS The proposed reconstruction method (GRASP + VS + KWIC) achieved better effective spatial resolution (i.e., image sharpness) compared with conventional GRASP, ultimately reducing the underestimation of peak velocity from 17.4% to 6.4%. The hemodynamic metrics (peak velocity, volumes) were not significantly (p > 0.99) different between GRASP + VS + KWIC and clinical PC, whereas peak velocity was significantly (p < 0.007) lower for conventional GRASP. RtPC with GRASP + VS + KWIC also showed the ability to assess beat-to-beat variation and detect the highest peak among peaks. CONCLUSION The synergistic combination of GRASP, VS, and KWIC achieves 25 ms effective temporal resolution (40 fps frame rate), while minimizing the underestimation of peak velocity compared with conventional GRASP.
Collapse
|
2
|
Tricuspid Atresia with Absent Pulmonary Valve with Nearly Discontinuous Branch Pulmonary Arteries. Pediatr Cardiol 2024; 45:446-451. [PMID: 37955720 DOI: 10.1007/s00246-023-03331-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2023] [Accepted: 10/16/2023] [Indexed: 11/14/2023]
Abstract
Absent pulmonary valve with tricuspid atresia or tricuspid stenosis (APV-TA/TS) is an extremely rare congenital heart defect associated with significant morbidity and mortality. Compared to Tetralogy of Fallot with Absent Pulmonary Valve Syndrome, branch pulmonary arteries are not typically significantly dilated. We present the case of a newborn male prenatally diagnosed APV-TA with intact ventricular septum (IVS) and nearly discontinuous branch pulmonary arteries, the surgical strategy employed, and the salient hemodynamic factors considered in the medical decision-making.
Collapse
|
3
|
Cardiac magnetic resonance imaging in detection of progressive graft dysfunction in pediatric heart transplantation. Pediatr Transplant 2024; 28:e14652. [PMID: 38063266 PMCID: PMC10872936 DOI: 10.1111/petr.14652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 11/01/2023] [Accepted: 11/04/2023] [Indexed: 02/07/2024]
Abstract
BACKGROUND Chronic graft failure (CGF) in pediatric heart transplant (PHT) is multifactorial and may present with findings of fibrosis and microvessel disease (MVD) on endomyocardial biopsy (EMB). There is no optimal CGF surveillance method. We evaluated associations between cardiac magnetic resonance imaging (CMR) and historical/EMB correlates of CGF to assess CMR's utility as a surveillance method. METHODS Retrospective analysis of PHT undergoing comprehensive CMR between September 2015 and January 2022 was performed. EMB within 6 months was graded for fibrosis (scale 0-5) and MVD (number of capillaries with stenotic wall thickening per field of view). Correlation analysis and logistic regression were performed. RESULTS Forty-seven PHT with median age at CMR of 15.7 years (11.6, 19.3) and time from transplant of 6.4 years (4.1, 11.0) were studied. Cardiac allograft vasculopathy (CAV) was present in 11/44 (22.0%) and historical rejection in 14/41 (34.2%). CAV was associated with higher global T2 (49.0 vs. 47.0 ms; p = 0.038) and peak T2 (57.0 vs. 53.0 ms; p = 0.013) on CMR. Historical rejection was associated with higher global T2 (49.0 vs. 47.0 ms; p = 0.007) and peak T2 (57.0 vs. 53.0 ms; p = 0.03) as well as global extracellular volume (31.0 vs. 26.3%; p = 0.03). Higher fibrosis score on EMB correlated with smaller indexed left ventricular mass (rho = -0.34; p = 0.019) and greater degree of MVD with lower indexed left ventricular end-diastolic volume (rho = -0.35; p = 0.017). CONCLUSION Adverse ventricular remodeling and abnormal myocardial characteristics on CMR are present in PHT with CAV, historical rejection, as well as greater fibrosis and MVD on EMB. CMR has the potential use for screening of CGF.
Collapse
|
4
|
Ultra-rapid, Free-breathing, Real-time Cardiac Cine MRI Using GRASP Amplified with View Sharing and KWIC Filtering. Radiol Cardiothorac Imaging 2024; 6:e230107. [PMID: 38358330 PMCID: PMC10912880 DOI: 10.1148/ryct.230107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 12/06/2023] [Accepted: 01/02/2024] [Indexed: 02/16/2024]
Abstract
Purpose To achieve ultra-high temporal resolution (approximately 20 msec) in free-breathing, real-time cardiac cine MRI using golden-angle radial sparse parallel (GRASP) reconstruction amplified with view sharing (VS) and k-space-weighted image contrast (KWIC) filtering. Materials and Methods Fourteen pediatric patients with congenital heart disease (mean age [SD], 9 years ± 2; 13 male) and 10 adult patients with arrhythmia (mean age, 62 years ± 8; nine male) who underwent both standard breath-hold cine and free-breathing real-time cine using GRASP were retrospectively identified. To achieve high temporal resolution, each time frame was reconstructed using six radial spokes, corresponding to acceleration factors ranging from 24 to 32. To compensate for loss in spatial resolution resulting from over-regularization in GRASP, VS and KWIC filtering were incorporated. The blur metric, visual image quality scores, and biventricular parameters were compared between clinical and real-time cine images. Results In pediatric patients, the incorporation of VS and KWIC into GRASP (ie, GRASP + VS + KWIC) produced significantly (P < .05) sharper x-y-t (blur metric: 0.36 ± 0.03, 0.41 ± 0.03, 0.48 ± 0.03, respectively) and x-y-f (blur metric: 0.28 ± 0.02, 0.31 ± 0.03, 0.37 ± 0.03, respectively) component images compared with GRASP + VS and conventional GRASP. Only the noise score differed significantly between GRASP + VS + KWIC and clinical cine; all visual scores were above the clinically acceptable (3.0) cutoff point. Biventricular volumetric parameters strongly correlated (R2 > 0.85) between clinical and real-time cine images reconstructed with GRASP + VS + KWIC and were in good agreement (relative error < 6% for all parameters). In adult patients, the visual scores of all categories were significantly lower (P < .05) for clinical cine compared with real-time cine with GRASP + VS + KWIC, except for noise (P = .08). Conclusion Incorporating VS and KWIC filtering into GRASP reconstruction enables ultra-high temporal resolution (approximately 20 msec) without significant loss in spatial resolution. Keywords: Cine, View Sharing, k-Space-weighted Image Contrast Filtering, Radial k-Space, Pediatrics, Arrhythmia, GRASP, Compressed Sensing, Real-Time, Free-Breathing Supplemental material is available for this article. © RSNA, 2024.
Collapse
|
5
|
A Deep Learning Pipeline for Assessing Ventricular Volumes from a Cardiac MRI Registry of Patients with Single Ventricle Physiology. Radiol Artif Intell 2024; 6:e230132. [PMID: 38166332 PMCID: PMC10831511 DOI: 10.1148/ryai.230132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2023] [Revised: 10/05/2023] [Accepted: 10/30/2023] [Indexed: 01/04/2024]
Abstract
Purpose To develop an end-to-end deep learning (DL) pipeline for automated ventricular segmentation of cardiac MRI data from a multicenter registry of patients with Fontan circulation (Fontan Outcomes Registry Using CMR Examinations [FORCE]). Materials and Methods This retrospective study used 250 cardiac MRI examinations (November 2007-December 2022) from 13 institutions for training, validation, and testing. The pipeline contained three DL models: a classifier to identify short-axis cine stacks and two U-Net 3+ models for image cropping and segmentation. The automated segmentations were evaluated on the test set (n = 50) by using the Dice score. Volumetric and functional metrics derived from DL and ground truth manual segmentations were compared using Bland-Altman and intraclass correlation analysis. The pipeline was further qualitatively evaluated on 475 unseen examinations. Results There were acceptable limits of agreement (LOA) and minimal biases between the ground truth and DL end-diastolic volume (EDV) (bias: -0.6 mL/m2, LOA: -20.6 to 19.5 mL/m2) and end-systolic volume (ESV) (bias: -1.1 mL/m2, LOA: -18.1 to 15.9 mL/m2), with high intraclass correlation coefficients (ICCs > 0.97) and Dice scores (EDV, 0.91 and ESV, 0.86). There was moderate agreement for ventricular mass (bias: -1.9 g/m2, LOA: -17.3 to 13.5 g/m2) and an ICC of 0.94. There was also acceptable agreement for stroke volume (bias: 0.6 mL/m2, LOA: -17.2 to 18.3 mL/m2) and ejection fraction (bias: 0.6%, LOA: -12.2% to 13.4%), with high ICCs (>0.81). The pipeline achieved satisfactory segmentation in 68% of the 475 unseen examinations, while 26% needed minor adjustments, 5% needed major adjustments, and in 0.4%, the cropping model failed. Conclusion The DL pipeline can provide fast standardized segmentation for patients with single ventricle physiology across multiple centers. This pipeline can be applied to all cardiac MRI examinations in the FORCE registry. Keywords: Cardiac, Adults and Pediatrics, MR Imaging, Congenital, Volume Analysis, Segmentation, Quantification Supplemental material is available for this article. © RSNA, 2023.
Collapse
|
6
|
A Deep Learning Approach to Using Wearable Seismocardiography (SCG) for Diagnosing Aortic Valve Stenosis and Predicting Aortic Hemodynamics Obtained by 4D Flow MRI. Ann Biomed Eng 2023; 51:2802-2811. [PMID: 37573264 DOI: 10.1007/s10439-023-03342-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Accepted: 07/27/2023] [Indexed: 08/14/2023]
Abstract
In this paper, we explored the use of deep learning for the prediction of aortic flow metrics obtained using 4-dimensional (4D) flow magnetic resonance imaging (MRI) using wearable seismocardiography (SCG) devices. 4D flow MRI provides a comprehensive assessment of cardiovascular hemodynamics, but it is costly and time-consuming. We hypothesized that deep learning could be used to identify pathological changes in blood flow, such as elevated peak systolic velocity ([Formula: see text]) in patients with heart valve diseases, from SCG signals. We also investigated the ability of this deep learning technique to differentiate between patients diagnosed with aortic valve stenosis (AS), non-AS patients with a bicuspid aortic valve (BAV), non-AS patients with a mechanical aortic valve (MAV), and healthy subjects with a normal tricuspid aortic valve (TAV). In a study of 77 subjects who underwent same-day 4D flow MRI and SCG, we found that the [Formula: see text] values obtained using deep learning and SCGs were in good agreement with those obtained by 4D flow MRI. Additionally, subjects with non-AS TAV, non-AS BAV, non-AS MAV, and AS could be classified with ROC-AUC (area under the receiver operating characteristic curves) values of 92%, 95%, 81%, and 83%, respectively. This suggests that SCG obtained using low-cost wearable electronics may be used as a supplement to 4D flow MRI exams or as a screening tool for aortic valve disease.
Collapse
|
7
|
Highly accelerated compressed sensing 4D flow MRI in congenital and acquired heart disease: comparison of aorta and main pulmonary artery flow parameters with conventional 4D flow MRI in children and young adults. Pediatr Radiol 2023; 53:2597-2607. [PMID: 37882844 DOI: 10.1007/s00247-023-05788-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 09/19/2023] [Accepted: 09/28/2023] [Indexed: 10/27/2023]
Abstract
BACKGROUND Four-dimensional flow (4D flow) MRI has become a clinically utilized cardiovascular flow assessment tool. However, scans can be lengthy and may require anesthesia in younger children. Adding compressed sensing can decrease scan time, but its impact on hemodynamic data accuracy needs additional assessment. OBJECTIVE To compare 4D flow hemodynamics acquired with and without compressed sensing. MATERIALS AND METHODS Twenty-seven patients (median age: 13 [IQR: 9.5] years) underwent conventional and compressed sensing cardiovascular 4D flow following informed consent. Conventional 4D flow was performed using parallel imaging and an acceleration factor of 2. Compressed sensing 4D flow was performed with an acceleration factor of 7.7. Regions of interest were placed to compare flow parameters in the ascending aorta and main pulmonary artery. Paired Student's t-tests, Wilcoxon signed-rank tests, Bland-Altman plots, and intraclass correlation coefficients were conducted. A P-value of < 0.05 was considered statistically significant. RESULTS Mean scan acquisition time was reduced by 59% using compressed sensing (3.4 vs. 8.2 min, P < 0.001). Flow quantification was similar for compressed sensing and conventional 4D flow for the ascending aorta net flow: 47 vs. 49 ml/beat (P = 0.28); forward flow: 49 vs. 50 ml/beat (P = 0.07), and main pulmonary artery net flow: 49 vs. 51 ml/beat (P = 0.18); forward flow: 50 vs. 55 ml/beat (P = 0.07). Peak systolic velocity was significantly underestimated by compressed sensing 4D flow in the ascending aorta: 114 vs. 128 cm/s (P < 0.001) and main pulmonary artery: 106 vs. 112 cm/s (P = 0.02). CONCLUSION For both the aorta and main pulmonary artery, compressed sensing 4D flow provided equivalent net and forward flow values compared to conventional 4D flow but underestimated peak systolic velocity. By reducing scan time, compressed sensing 4D flow may decrease the need for anesthesia and increase scanner output without significantly compromising data integrity.
Collapse
|
8
|
Late-gadolinium enhancement is common in older pediatric heart transplant recipients and is associated with lower ejection fraction. J Cardiovasc Magn Reson 2023; 25:61. [PMID: 37932797 PMCID: PMC10626738 DOI: 10.1186/s12968-023-00971-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Accepted: 10/19/2023] [Indexed: 11/08/2023] Open
Abstract
BACKGROUND Chronic graft failure and cumulative rejection history in pediatric heart transplant recipients (PHTR) are associated with myocardial fibrosis on endomyocardial biopsy (EMB). Cardiovascular magnetic resonance imaging (CMR) is a validated, non-invasive method to detect myocardial fibrosis via the presence of late gadolinium enhancement (LGE). In adult heart transplant recipients, LGE is associated with increased risk of future adverse clinical events including hospitalization and death. We describe the prevalence, pattern, and extent of LGE on CMR in a cohort of PHTR and its associations with recipient and graft characteristics. METHODS This was a retrospective study of consecutive PHTR who underwent CMR over a 6-year period at a single center. Two independent reviewers assessed the presence and distribution of left ventricular (LV) LGE using the American Heart Association (AHA) 17-segment model. LGE quantification was performed on studies with visible fibrosis (LGE+). Patient demographics, clinical history, and CMR-derived volumetry and ejection fractions were obtained. RESULTS Eighty-one CMR studies were performed on 59 unique PHTR. Mean age at CMR was 14.8 ± 6.2 years; mean time since transplant was 7.3 ± 5.0 years. The CMR indication was routine surveillance (without a clinical concern based on laboratory parameters, echocardiography, or cardiac catheterization) in 63% (51/81) of studies. LGE was present in 36% (29/81) of PHTR. In these LGE + studies, patterns included inferoseptal in 76% of LGE + studies (22/29), lateral wall in 41% (12/29), and diffuse, involving > 4 AHA segments, in 21% (6/29). The mean LV LGE burden as a percentage of myocardial mass was 18.0 ± 9.0%. When reviewing only the initial CMR per PHTR (n = 59), LGE + patients were older (16.7 ± 2.9 vs. 12.8 ± 4.6 years, p = 0.001), with greater time since transplant (8.3 ± 5.4 vs. 5.7 ± 3.9 years, p = 0.041). These patients demonstrated higher LV end-systolic volume index (LVESVI) (34.7 ± 11.7 vs. 28.7 ± 6.1 ml/m2, p = 0.011) and decreased LV ejection fraction (LVEF) (56.2 ± 8.1 vs. 60.6 ± 5.3%, p = 0.015). There were no significant differences in history of moderate/severe rejection (p = 0.196) or cardiac allograft vasculopathy (CAV) (p = 0.709). CONCLUSIONS LV LGE was present in approximately one third of PHTR, more commonly in older patients with longer time since transplantation. Grafts with LGE have lower LVEF. CMR-derived LGE may aid in surveillance of chronic graft failure in PHTR.
Collapse
|
9
|
Right Ventricular Remodeling Assessed by
MRI
in Duchenne Muscular Dystrophy. J Magn Reson Imaging 2022. [PMID: 36354274 PMCID: PMC10169546 DOI: 10.1002/jmri.28521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 10/14/2022] [Accepted: 10/18/2022] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND In Duchenne muscular dystrophy (DMD), the right ventricle (RV) tends to be relatively well preserved, but characterization remains difficult due to its complex architecture. Tissue phase mapping (TPM) is a phase contrast cine MRI technique that allows for multidirectional assessment of myocardial velocities. PURPOSE To use TPM to elucidate relationships between myocardial structure, function, and clinical variables in DMD. STUDY TYPE Retrospective. SUBJECTS A total of 20 patients with muscular dystrophy (median age: 16 years); 18 age-matched normal controls (median age: 15 years). FIELD STRENGTH/SEQUENCE Three-directional velocity encoded cine gradient echo sequence (TPM) at 1.5 T, balanced steady-state free procession (bSSFP), T1 mapping with extracellular volume (ECV), and late gadolinium enhancement (LGE). ASSESSMENT TPM in basal, mid, and apical short-axis planes was performed as part of a standard MRI study with collection of clinical data. Radial, circumferential, and longitudinal velocities (Vr, Vφ, and Vz, respectively) and corresponding time to peak (TTP) velocities were quantified from TPM and used to calculate RV twist as well as intraventricular and interventricular dyssynchrony. The correlations between TPM velocities, myocardial structure/function, and clinical variables were assessed. STATISTICAL TEST Unpaired t-test, Wilcoxon rank-sum test, Bland-Altman analyses were used for comparisons between DMD patients and controls and between DMD subgroups. Pearson's test was used for correlations (r). Significance level: P < 0.05. RESULTS Compared to controls, DMD patients had preserved RV ejection fraction (RVEF 53% ± 8%) but significantly increased interventricular dyssynchrony (Vφ: 0.49 ± 0.21 vs. 0.72 ± 0.17). Within the DMD cohort, RV dyssynchrony significantly increased with lower LV ejection fraction (intraventricular Vr and Vz: r = -0.49; interventricular Vz: r = 0.48). In addition, RV intraventricular dyssynchrony significantly increased with older age (Vz: r = 0.67). DATA CONCLUSION RV remodeling in DMD occurs in the context of preserved RVEF. Within DMD, this abnormal RV deformation is associated with older age and decreased LVEF. EVIDENCE LEVEL 4. TECHNICAL EFFICACY Stage 2.
Collapse
|
10
|
Safety and Efficacy of Regadenoson for Pediatric Stress Perfusion Cardiac MRI with Quantification of Myocardial Blood Flow. CHILDREN (BASEL, SWITZERLAND) 2022; 9:children9091332. [PMID: 36138640 PMCID: PMC9497237 DOI: 10.3390/children9091332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 08/15/2022] [Accepted: 08/29/2022] [Indexed: 11/16/2022]
Abstract
Myocardial stress perfusion magnetic resonance imaging is a non-invasive tool to assess for myocardial ischemia and viability. Pediatric myocardial stress perfusion MRI can be challenging due to multiple intravenous lines, sedation, inadequate breath holding, fast heart rates, and complex anatomy. We performed a retrospective analysis in 39 children to evaluate safety and efficacy of regadenoson, a coronary vasodilator administered via a single intravenous line (6−10 mcg/kg), with respiratory motion correction (MOCO) and semi-quantitative blood flow analysis. Stress response data and adverse events were recorded, and image quality compared between native and MOCO reconstructions, assessing for perfusion deficits. Semi-quantitative analysis compared myocardial perfusion reserve index (MPRI) between patients who had a focal perfusion defect, patients who had undergone an orthotopic heart transplant, and non-transplant patients with no focal defects. Stress perfusion was completed in 38/39 patients (median age 15 years with a 41 ± 27% rise in heart rate (p < 0.005). Fifteen out of thirty-eight had transient minor side effects with no major adverse events. MOCO image quality was better than non-MOCO (4.63 vs. 4.01 at rest, p < 0.005: 4.41 vs. 3.84 at stress, p < 0.005). Reversible perfusion defects were seen in 4/38 patients with lower segmental mean MPRI in the area of the perfusion defect, nearing statistical significance when compared to non-transplant patients with no defects (0.78 ± 0.22 vs. 0.99 ± 0.36, p = 0.07). The global MPRI of the 16 patients who had undergone orthotopic heart transplant was significantly lower than the non-transplant patients (0.75 ± 0.22 vs. 0.92 ± 0.23, p = 0.03). Regadenoson is a safe and effective coronary vasodilator for pediatric stress perfusion MRI with MOCO producing better image quality and allowing for semi-quantitative assessment of perfusion deficits that correlate with qualitative assessment.
Collapse
|
11
|
The need for comprehensive multidisciplinary programs, complex interventions, and precision medicine for bicuspid aortic valve disease. Ann Cardiothorac Surg 2022; 11:369-379. [PMID: 35958531 PMCID: PMC9357958 DOI: 10.21037/acs-2021-bav-207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Accepted: 02/08/2022] [Indexed: 11/17/2022]
Abstract
Patients with bicuspid aortic valves commonly require an intervention on their valve and/or aorta. Because of their heterogeneous presentations, recommendations for imaging surveillance and surgery timing are highly individualized. Critical points in care include time of diagnosis, transition from adolescent to adult medicine, and surgery referral. To better support patients with bicuspid aortic valves, we developed a comprehensive program that utilizes the multidisciplinary care team, complex interventions, and translational research protocols. We describe our program structure and experience with this common and sometimes challenging diagnosis.
Collapse
|
12
|
Deep learning-based velocity antialiasing of 4D-flow MRI. Magn Reson Med 2022; 88:449-463. [PMID: 35381116 PMCID: PMC9050855 DOI: 10.1002/mrm.29205] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2021] [Revised: 01/13/2022] [Accepted: 02/07/2022] [Indexed: 01/03/2023]
Abstract
Purpose To develop a convolutional neural network (CNN) for the robust and fast correction of velocity aliasing in 4D‐flow MRI. Methods This study included 667 adult subjects with aortic 4D‐flow MRI data with existing velocity aliasing (n = 362) and no velocity aliasing (n = 305). Additionally, 10 controls received back‐to‐back 4D‐flow scans with systemically varied velocity‐encoding sensitivity (vencs) at 60, 100, and 175 cm/s. The no‐aliasing data sets were used to simulate velocity aliasing by reducing the venc to 40%–70% of the original, alongside a ground truth locating all aliased voxels (153 training, 152 testing). The 152 simulated and 362 existing aliasing data sets were used for testing and compared with a conventional velocity antialiasing algorithm. Dice scores were calculated to quantify CNN performance. For controls, the venc 175‐cm/s scans were used as the ground truth and compared with the CNN‐corrected venc 60 and 100 cm/s data sets Results The CNN required 176 ± 30 s to perform compared with 162 ± 14 s for the conventional algorithm. The CNN showed excellent performance for the simulated data compared with the conventional algorithm (median range of Dice scores CNN: [0.89–0.99], conventional algorithm: [0.84–0.94], p < 0.001, across all simulated vencs) and detected more aliased voxels in existing velocity aliasing data sets (median detected CNN: 159 voxels [31–605], conventional algorithm: 65 [7–417], p < 0.001). For controls, the CNN showed Dice scores of 0.98 [0.95–0.99] and 0.96 [0.87–0.99] for venc = 60 cm/s and 100 cm/s, respectively, while flow comparisons showed moderate‐excellent agreement. Conclusion Deep learning enabled fast and robust velocity anti‐aliasing in 4D‐flow MRI.
Collapse
|
13
|
Multi-parametric cardiovascular magnetic resonance with regadenoson stress perfusion is safe following pediatric heart transplantation and identifies history of rejection and cardiac allograft vasculopathy. J Cardiovasc Magn Reson 2021; 23:135. [PMID: 34809650 PMCID: PMC8607604 DOI: 10.1186/s12968-021-00803-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Accepted: 08/10/2021] [Indexed: 01/02/2023] Open
Abstract
BACKGROUND The progressive risk of graft failure in pediatric heart transplantation (PHT) necessitates close surveillance for rejection and coronary allograft vasculopathy (CAV). The current gold standard of surveillance via invasive coronary angiography is costly, imperfect and associated with complications. Our goal was to assess the safety and feasibility of a comprehensive multi-parametric CMR protocol with regadenoson stress perfusion in PHT and evaluate for associations with clinical history of rejection and CAV. METHODS We performed a retrospective review of 26 PHT recipients who underwent stress CMR with tissue characterization and compared with 18 age-matched healthy controls. CMR protocol included myocardial T2, T1 and extracellular volume (ECV) mapping, late gadolinium enhancement (LGE), qualitative and semi-quantitative stress perfusion (myocardial perfusion reserve index; MPRI) and strain imaging. Clinical, demographics, rejection score and CAV history were recorded and correlated with CMR parameters. RESULTS Mean age at transplant was 9.3 ± 5.5 years and median duration since transplant was 5.1 years (IQR 7.5 years). One patient had active rejection at the time of CMR, 11/26 (42%) had CAV 1 and 1/26 (4%) had CAV 2. Biventricular volumes were smaller and cardiac output higher in PHT vs. healthy controls. Global T1 (1053 ± 42 ms vs 986 ± 42 ms; p < 0.001) and ECV (26.5 ± 4.0% vs 24.0 ± 2.7%; p = 0.017) were higher in PHT compared to helathy controls. Significant relationships between changes in myocardial tissue structure and function were noted in PHT: increased T2 correlated with reduced LVEF (r = - 0.57, p = 0.005), reduced global circumferential strain (r = - 0.73, p < 0.001) and reduced global longitudinal strain (r = - 0.49, p = 0.03). In addition, significant relationships were noted between higher rejection score and global T1 (r = 0.38, p = 0.05), T2 (r = 0.39, p = 0.058) and ECV (r = 0.68, p < 0.001). The presence of even low-grade CAV was associated with higher global T1, global ECV and maximum segmental T2. No major side effects were noted with stress testing. MPRI was analyzed with good interobserver reliability and was lower in PHT compared to healthy controls (0.69 ± - 0.21 vs 0.94 ± 0.22; p < 0.001). CONCLUSION In a PHT population with low incidence of rejection or high-grade CAV, CMR demonstrates important differences in myocardial structure, function and perfusion compared to age-matched healthy controls. Regadenoson stress perfusion CMR could be safely and reliably performed. Increasing T2 values were associated with worsening left ventricular function and increasing T1/ECV values were associated with rejection history and low-grade CAV. These findings warrant larger prospective studies to further define the role of CMR in PHT graft surveillance.
Collapse
|
14
|
Segmentation of the Aorta and Pulmonary Arteries Based on 4D Flow MRI in the Pediatric Setting Using Fully Automated Multi-Site, Multi-Vendor, and Multi-Label Dense U-Net. J Magn Reson Imaging 2021; 55:1666-1680. [PMID: 34792835 DOI: 10.1002/jmri.27995] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Revised: 11/04/2021] [Accepted: 11/05/2021] [Indexed: 01/14/2023] Open
Abstract
BACKGROUND Automated segmentation using convolutional neural networks (CNNs) have been developed using four-dimensional (4D) flow magnetic resonance imaging (MRI). To broaden usability for congenital heart disease (CHD), training with multi-institution data is necessary. However, the performance impact of heterogeneous multi-site and multi-vendor data on CNNs is unclear. PURPOSE To investigate multi-site CNN segmentation of 4D flow MRI for pediatric blood flow measurement. STUDY TYPE Retrospective. POPULATION A total of 174 subjects across two sites (female: 46%; N = 38 healthy controls, N = 136 CHD patients). Participants from site 1 (N = 100), site 2 (N = 74), and both sites (N = 174) were divided into subgroups to conduct 10-fold cross validation (10% for testing, 90% for training). FIELD STRENGTH/SEQUENCE 3 T/1.5 T; retrospectively gated gradient recalled echo-based 4D flow MRI. ASSESSMENT Accuracy of the 3D CNN segmentations trained on data from single site (single-site CNNs) and data across both sites (multi-site CNN) were evaluated by geometrical similarity (Dice score, human segmentation as ground truth) and net flow quantification at the ascending aorta (Qs), main pulmonary artery (Qp), and their balance (Qp/Qs), between human observers, single-site and multi-site CNNs. STATISTICAL TESTS Kruskal-Wallis test, Wilcoxon rank-sum test, and Bland-Altman analysis. A P-value <0.05 was considered statistically significant. RESULTS No difference existed between single-site and multi-site CNNs for geometrical similarity in the aorta by Dice score (site 1: 0.916 vs. 0.915, P = 0.55; site 2: 0.906 vs. 0.904, P = 0.69) and for the pulmonary arteries (site 1: 0.894 vs. 0.895, P = 0.64; site 2: 0.870 vs. 0.869, P = 0.96). Qs site-1 medians were 51.0-51.3 mL/cycle (P = 0.81) and site-2 medians were 66.7-69.4 mL/cycle (P = 0.84). Qp site-1 medians were 46.8-48.0 mL/cycle (P = 0.97) and site-2 medians were 76.0-77.4 mL/cycle (P = 0.98). Qp/Qs site-1 medians were 0.87-0.88 (P = 0.97) and site-2 medians were 1.01-1.03 (P = 0.43). Bland-Altman analysis for flow quantification found equivalent performance. DATA CONCLUSION Multi-site CNN-based segmentation and blood flow measurement are feasible for pediatric 4D flow MRI and maintain performance of single-site CNNs. LEVEL OF EVIDENCE 3 TECHNICAL EFFICACY: Stage 2.
Collapse
|
15
|
Editorial for "Cardiac Magnetic Resonance Follow-Up of Children After Pediatric Inflammatory Multisystem Syndrome Temporally Associated with SARS-CoV-2 (PIMS-TS) and Initial Cardiac Involvement". J Magn Reson Imaging 2021; 55:892-894. [PMID: 34528325 PMCID: PMC8662045 DOI: 10.1002/jmri.27926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 09/09/2021] [Indexed: 11/18/2022] Open
|
16
|
Abstract
Myocarditis remains a clinical challenge in pediatrics. Originally, it was recognized at autopsy before the application of endomyocardial biopsy, which led to a histopathology-based diagnosis such as in the Dallas criteria. Given the invasive and low-sensitivity nature of endomyocardial biopsy, its diagnostic focus shifted to a reliance on clinical suspicion. With the advances of cardiac magnetic resonance, an examination of the whole heart in vivo has gained acceptance in the pursuit of a diagnosis of myocarditis. The presentation may vary from minimal symptoms to heart failure, life-threatening arrhythmias, or cardiogenic shock. Outcomes span full resolution to chronic heart failure and the need for heart transplantation with inadequate clues to predict the disease trajectory. The American Heart Association commissioned this writing group to explore the current knowledge and management within the field of pediatric myocarditis. This statement highlights advances in our understanding of the immunopathogenesis, new and shifting dominant pathogeneses, modern laboratory testing, and use of mechanical circulatory support, with a special emphasis on innovations in cardiac magnetic resonance imaging. Despite these strides forward, we struggle without a universally accepted definition of myocarditis, which impedes progress in disease-targeted therapy.
Collapse
|
17
|
Cardiovascular magnetic resonance imaging in children after recovery from symptomatic COVID-19 or MIS-C: a prospective study. J Cardiovasc Magn Reson 2021; 23:86. [PMID: 34193197 PMCID: PMC8245157 DOI: 10.1186/s12968-021-00786-5] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Accepted: 06/07/2021] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Cardiac evaluations, including cardiovascular magnetic resonance (CMR) imaging and biomarker results, are needed in children during mid-term recovery after infection with SARS-CoV-2. The incidence of CMR abnormalities 1-3 months after recovery is over 50% in older adults and has ranged between 1 and 15% in college athletes. Abnormal cardiac biomarkers are common in adults, even during recovery. METHODS We performed CMR imaging in a prospectively-recruited pediatric cohort recovered from COVID-19 and multisystem inflammatory syndrome in children (MIS-C). We obtained CMR data and serum biomarkers. We compared these results to age-matched control patients, imaged prior to the SARS-CoV-2 pandemic. RESULTS CMR was performed in 17 children (13.9 years, all ≤ 18 years) and 29 age-matched control patients without SARS-CoV-2 infection. Cases were recruited with symptomatic COVID-19 (11/17, 65%) or MIS-C (6/17, 35%) and studied an average of 2 months after diagnosis. All COVID-19 patients had been symptomatic with fever (73%), vomiting/diarrhea (64%), or breathing difficulty (55%) during infection. Left ventricular and right ventricular ejection fractions were indistinguishable between cases and controls (p = 0.66 and 0.70, respectively). Mean native global T1, global T2 values and segmental T2 maximum values were also not statistically different from control patients (p ≥ 0.06 for each). NT-proBNP and troponin levels were normal in all children. CONCLUSIONS Children prospectively recruited following SARS-CoV-2 infection had normal CMR and cardiac biomarker evaluations during mid-term recovery. Trial Registration Not applicable.
Collapse
|
18
|
Editorial for “Children With Acute Myocarditis Often Have Persistent Subclinical Changes as Revealed by Cardiac Magnetic Resonance”. J Magn Reson Imaging 2020; 52:497-498. [DOI: 10.1002/jmri.27186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Accepted: 04/21/2020] [Indexed: 11/10/2022] Open
|
19
|
Highly accelerated, real-time phase-contrast MRI using radial k-space sampling and GROG-GRASP reconstruction: a feasibility study in pediatric patients with congenital heart disease. NMR IN BIOMEDICINE 2020; 33:e4240. [PMID: 31977117 PMCID: PMC7165070 DOI: 10.1002/nbm.4240] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2019] [Revised: 11/04/2019] [Accepted: 11/19/2019] [Indexed: 06/10/2023]
Abstract
Retrospective electrocardiogram-gated, 2D phase-contrast (PC) flow MRI is routinely used in clinical evaluation of valvular/vascular disease in pediatric patients with congenital heart disease (CHD). In patients not requiring general anesthesia, clinical standard PC is conducted with free breathing for several minutes per slice with averaging. In younger patients under general anesthesia, clinical standard PC is conducted with breath-holding. One approach to overcome this limitation is using either navigator gating or self-navigation of respiratory motion, at the expense of lengthening scan times. An alternative approach is using highly accelerated, free-breathing, real-time PC (rt-PC) MRI, which to date has not been evaluated in CHD patients. The purpose of this study was to develop a 38.4-fold accelerated 2D rt-PC pulse sequence using radial k-space sampling and compressed sensing with 1.5 × 1.5 × 6.0 mm3 nominal spatial resolution and 40 ms nominal temporal resolution, and evaluate whether it is capable of accurately measuring flow in 17 pediatric patients (aortic valve, pulmonary valve, right and left pulmonary arteries) compared with clinical standard 2D PC (either breath-hold or free breathing). For clinical translation, we implemented an integrated reconstruction pipeline capable of producing DICOMs of the order of 2 min per time series (46 frames). In terms of association, forward volume, backward volume, regurgitant fraction, and peak velocity at peak systole measured with standard PC and rt-PC were strongly correlated (R2 > 0.76; P < 0.001). Compared with clinical standard PC, in terms of agreement, forward volume (mean difference = 1.4% (3.0% of mean)) and regurgitant fraction (mean difference = -2.5%) were in good agreement, whereas backward volume (mean difference = -1.1 mL (28.2% of mean)) and peak-velocity at peak systole (mean difference = -21.3 cm/s (17.2% of mean)) were underestimated by rt-PC. This study demonstrates that the proposed rt-PC with the said spatial resolution and temporal resolution produces relatively accurate forward volumes and regurgitant fractions but underestimates backward volumes and peak velocities at peak systole in pediatric patients with CHD.
Collapse
|
20
|
Fully automated 3D aortic segmentation of 4D flow MRI for hemodynamic analysis using deep learning. Magn Reson Med 2020; 84:2204-2218. [PMID: 32167203 DOI: 10.1002/mrm.28257] [Citation(s) in RCA: 74] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 02/18/2020] [Accepted: 02/24/2020] [Indexed: 12/18/2022]
Abstract
PURPOSE To generate fully automated and fast 4D-flow MRI-based 3D segmentations of the aorta using deep learning for reproducible quantification of aortic flow, peak velocity, and dimensions. METHODS A total of 1018 subjects with aortic 4D-flow MRI (528 with bicuspid aortic valve, 376 with tricuspid aortic valve and aortic dilation, 114 healthy controls) comprised the data set. A convolutional neural network was trained to generate 3D aortic segmentations from 4D-flow data. Manual segmentations served as the ground truth (N = 499 training, N = 101 validation, N = 418 testing). Dice scores, Hausdorff distance, and average symmetrical surface distance were calculated to assess performance. Aortic flow, peak velocity, and lumen dimensions were quantified at the ascending, arch, and descending aorta and compared using Bland-Altman analysis. Interobserver variability of manual analysis was assessed on a subset of 40. RESULTS Convolutional neural network segmentation required 0.438 ± 0.355 seconds versus 630 ± 254 seconds for manual analysis and demonstrated excellent performance with a median Dice score of 0.951 (0.930-0.966), Hausdorff distance of 2.80 (2.13-4.35), and average symmetrical surface distance of 0.176 (0.119-0.290). Excellent agreement was found for flow, peak velocity, and dimensions with low bias and limits of agreement less than 10% difference versus manual analysis. For aortic volume, limits of agreement were moderate within 16.3%. Interobserver variability (median Dice score: 0.950; Hausdorff distance: 2.45; and average symmetrical surface distance: 0.145) and convolutional neural network-based analysis (median Dice score: 0.953-0.959; Hausdorff distance: 2.24-2.91; and average symmetrical surface distance: 0.145-1.98 to observers) demonstrated similar reproducibility. CONCLUSIONS Deep learning enabled fast and automated 3D aortic segmentation from 4D-flow MRI, demonstrating its potential for efficient clinical workflows. Future studies should investigate its utility for other vasculature and multivendor applications.
Collapse
|
21
|
Eccentric Enlargement of the Aortic Sinuses in Pediatric and Adult Patients with Bicuspid Aortic Valves: A Cardiac MRI Study. Pediatr Cardiol 2020; 41:350-360. [PMID: 31858201 DOI: 10.1007/s00246-019-02264-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Accepted: 12/07/2019] [Indexed: 01/22/2023]
Abstract
Aortic root size and cusp fusion pattern have been related to disease outcomes in bicuspid aortic valve (BAV). This study seeks to characterize symmetry of the aortic sinuses in adult and pediatric BAV patients and its relationship to valvulopathy and root aortopathy. Aortic sinus-to-commissure (S-C) lengths were measured on cardiac MRI of adult and pediatric BAV patients with right-and-left coronary (RL) or right-and-non-coronary (RN) leaflet fusion and tricuspid aortic valve (TAV) controls. Coefficient of variance (CoV) of S-C lengths was calculated to quantify sinus asymmetry, or eccentricity. BAV cohort included 149 adults (48 ± 15 years) and 51 children (15 ± 5 years). TAV cohort included 40 adults (60 ± 13 years) and 20 children (15 ± 5 years). In adult and pediatric BAV patients, the non-fused aortic sinus was larger than either fused sinus. In RL fusion, the non-coronary S-C distance was larger than right or left S-C distances in adults (n = 121, p < 0.001) and larger than the right S-C distance in children (n = 41, p = 0.013). Sinus eccentricity (CoV) in BAV patients was higher than in TAV patients (p < 0.001) and did not correlate with age (p = 0.12). CoV trended higher in RL adults with aortic regurgitation (AR) compared to those without AR (p = 0.081), but was lower in RN adults with AR than without AR (p = 0.006). CoV did not correlate to root Z scores (p = 0.06-0.55) or ascending aortic (AAo) Z scores in adults (p = 0.45-0.55) but correlated negatively to AAo Z score in children (p = 0.005-0.03). Most adult and pediatric BAV patients with RL and RN leaflet fusion demonstrate eccentric dominance of the non-fused aortic sinus irrespective of age. The degree of eccentricity varies with valve dysfunction and BAV phenotype but does not relate to the degree of aortic root dilatation, nor does eccentricity correlate with ascending aorta dilatation in adults.
Collapse
|
22
|
Intraoperative Methadone Is Associated with Decreased Perioperative Opioid Use Without Adverse Events: A Case-Matched Cohort Study. J Cardiothorac Vasc Anesth 2019; 34:335-341. [PMID: 31699597 DOI: 10.1053/j.jvca.2019.09.033] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Revised: 09/21/2019] [Accepted: 09/25/2019] [Indexed: 11/11/2022]
Abstract
OBJECTIVE To determine if there is an association of intraoperative methadone use and total perioperative opioid exposure in patients undergoing congenital heart surgeries. DESIGN Retrospective, case-match cohort study. SETTING Single center quaternary care teaching hospital. PARTICIPANTS Seventy-four patients with congenital heart disease (CHD) undergoing surgical repair or palliative surgery. INTERVENTION Thirty-seven patients undergoing CHD surgeries receiving intraoperative methadone were matched to 37 patients based upon age and procedure who did not receive intraoperative methadone. The primary study outcome was to evaluate total opioid use in intravenous milligrams of morphine equivalents per kilogram (mg ME/kg) within the first 36-hours postoperatively. Mann-Whitney U test was used to compare total opioid exposure. MEASUREMENTS AND MAIN RESULTS The total opioid use was compared between groups. The methadone cohort required less opioids intraoperatively, in the first 12 hours postoperatively, and during the first 36 hours postoperatively (2.51 v 4.39 mg ME/kg, p < 0.001; 0.43 v 1.28 mg ME/kg, p = 0.001; and 0.83 v 1.91 mg ME/kg, p < 0.001) compared with the matched control cohort. There were no differences in clinical outcomes or adverse events. A dose-dependent reduction in opioid consumption in high- versus low-dose groups also was not observed. CONCLUSION Intraoperative methadone use was associated with a decrease in perioperative opioid exposure in patients undergoing congenital heart surgery and was not associated with adverse events or prolonged durations of mechanical ventilation or ICU stay.
Collapse
|
23
|
Myocardial velocity, intra-, and interventricular dyssynchrony evaluated by tissue phase mapping in pediatric heart transplant recipients. J Magn Reson Imaging 2019; 51:1212-1222. [PMID: 31515865 DOI: 10.1002/jmri.26916] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Accepted: 08/15/2019] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Endomyocardial biopsy (EMB) is the standard method for detecting allograft rejection in pediatric heart transplants (Htx). As EMB is invasive and carries a risk of complications, there is a need for a noninvasive alternative for allograft monitoring. PURPOSE To quantify left and right ventricular (LV & RV) peak velocities, velocity twist, and intra-/interventricular dyssynchrony using tissue phase mapping (TPM) in pediatric Htx compared with controls, and to explore the relationship between global cardiac function parameters and the number of rejection episodes to these velocities and intra-/interventricular dyssynchrony. STUDY TYPE Prospective. SUBJECTS Twenty Htx patients (age: 16.0 ± 3.1 years, 11 males) and 18 age- and sex-matched controls (age: 15.5 ± 4.3 years, nine males). FIELD STRENGTH/SEQUENCE 5T; 2D balanced cine steady-state free-precession (bSSFP), TPM (2D cine phase contrast with three-directional velocity encoding). ASSESSMENT LV and RV circumferential, radial, and long-axis velocity-time curves, global and segmental peak velocities were measured using TPM. Short-axis bSSFP images were used to measure global LV and RV function parameters. STATISTICAL TESTS A normality test (Lilliefors test) was performed on all data. For comparisons, a t-test was used for normally distributed data or a Wilcoxon rank-sum test otherwise. Correlations were determined by a Pearson correlation. RESULTS Htx patients had significantly reduced LV (P < 0.05-0.001) and RV (P < 0.05-0.001) systolic and diastolic global and segmental long-axis velocities, reduced RV diastolic peak twist (P < 0.01), and presented with higher interventricular dyssynchrony for long-axis and circumferential motions (P < 0.05-0.001). LV diastolic long-axis dyssynchrony (r = 0.48, P = 0.03) and RV diastolic peak twist (r = -0.64, P = 0.004) significantly correlated with the total number of rejection episodes. DATA CONCLUSION TPM detected differences in biventricular myocardial velocities in pediatric Htx patients compared with controls and indicated a relationship between Htx myocardial velocities and rejection history. LEVEL OF EVIDENCE 2 Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2020;51:1212-1222.
Collapse
|
24
|
Diagnostic performance of cardiovascular magnetic resonance native T1 and T2 mapping in pediatric patients with acute myocarditis. J Cardiovasc Magn Reson 2019; 21:40. [PMID: 31307467 PMCID: PMC6631973 DOI: 10.1186/s12968-019-0550-7] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Accepted: 06/14/2019] [Indexed: 01/06/2023] Open
Abstract
BACKGROUND Multiple studies in adult patients suggest that tissue mapping performed by cardiovascular magnetic resonance (CMR) has excellent diagnostic accuracy in acute myocarditis, however, these techniques have not been studied in depth in children. METHODS CMR data on 23 consecutive pediatric patients from 2014 to 2017 with a clinical diagnosis of acute myocarditis were retrospectively analyzed and compared to 39 healthy controls. The CMR protocol included native T1, T2, and extracellular volume fraction (ECV) in addition to standard Lake Louise Criteria (LLC) parameters on a 1.5 T scanner. RESULTS Mean global values for novel mapping parameters were significantly elevated in patients with clinically suspected acute myocarditis compared to controls, with native T1 1098 ± 77 vs 990 ± 34 ms, T2 52.8 ± 4.6 ms vs 46.7 ± 2.6 ms, and ECV 29.8 ± 5.1% vs 23.3 ± 2.6% (all p-values < 0.001). Ideal cutoff values were generated using corresponding ROC curves and were for global T1 1015 ms (AUC 0.936, sensitivity 91%, specificity 86%), for global T2 48.5 ms (AUC 0.908, sensitivity 91%, specificity 74%); and for ECV 25.9% (AUC 0.918, sensitivity 86%, specificity 89%). While the diagnostic yield of the LLC was 57% (13/23) in our patient cohort, 70% (7/10) of patients missed by the LLC demonstrated abnormalities across all three global mapping parameters (native T1, T2, and ECV) and another 20% (2/10) of patients demonstrated at least one abnormal mapping value. CONCLUSIONS Similar to findings in adults, pediatric patients with acute myocarditis demonstrate abnormal CMR tissue mapping values compared to controls. Furthermore, we found CMR parametric mapping techniques measurably increased CMR diagnostic yield when compared with conventional LLC alone, providing additional sensitivity and specificity compared to historical references. Routine integration of these techniques into imaging protocols may aid diagnosis in children.
Collapse
|
25
|
Caval to pulmonary 3D flow distribution in patients with Fontan circulation and impact of potential 4D flow MRI error sources. Magn Reson Med 2018; 81:1205-1218. [PMID: 30277276 DOI: 10.1002/mrm.27455] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2017] [Revised: 06/07/2018] [Accepted: 06/26/2018] [Indexed: 11/08/2022]
Abstract
PURPOSE Uneven flow distribution in patients with Fontan circulation is suspected to lead to complications. 4D flow MRI offers evaluation using time-resolved pathlines; however, the potential error is not well understood. The aim of this study was to systematically assess variability in flow distribution caused by well-known sources of error. METHODS 4D flow MRI was acquired in 14 patients with Fontan circulation. Flow distribution was quantified by the % of caval venous flow pathlines reaching the left and right pulmonary arteries. Impact of data acquisition and data processing uncertainties were investigated by (1) probabilistic 4D blood flow tracking at varying noise levels, (2) down-sampling to mimic acquisition at different spatial resolutions, (3) pathline calculation with and without eddy current correction, and (4) varied segmentation of the Fontan geometry to mimic analysis errors. RESULTS Averaged among the cohort, uncertainties accounted for flow distribution errors from noise ≤3.2%, low spatial resolution ≤2.3% to 3.8%, eddy currents ≤6.4%, and inaccurate segmentation ≤3.9% to 9.1% (dilation and erosion, respectively). In a worst-case scenario (maximum additive errors for all 4 sources), flow distribution errors were as high as 22.5%. CONCLUSION Inaccuracies related to postprocessing (segmentation, eddy currents) resulted in the largest potential error (≤15.5% combined) whereas errors related to data acquisition (noise, low spatial resolution) had a lower impact (≤5.5%-7.0% combined). Whereas it is unlikely that these errors will be additive or affect the identification of severe asymmetry, these results illustrate the importance of eddy current correction and accurate segmentation to minimize Fontan flow distribution errors.
Collapse
|
26
|
Giant coronary artery aneurysms in an infant with Kawasaki disease: Evaluation by echocardiography and computed tomographic angiography. Echocardiography 2018; 35:1692-1694. [PMID: 30099768 DOI: 10.1111/echo.14118] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Revised: 06/18/2018] [Accepted: 07/15/2018] [Indexed: 11/29/2022] Open
Abstract
Kawasaki disease (KD) is a vasculitis that affects medium-sized arteries and can lead to coronary artery aneurysms. KD should be considered in any infant presenting with prolonged fever. Delaying treatment beyond Day 10 of fever portends a high risk of coronary artery aneurysms. Echocardiography is often necessary to diagnose KD in young infants who frequently present without classic physical examination findings. We report on a case of KD with giant aneurysms in a 2-month-old infant. A combination of transthoracic echocardiography and CT angiography was utilized in the diagnosis as well as in the management of this infant.
Collapse
|
27
|
Aggregation of Markov flows I: theory. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2018; 376:rsta.2017.0232. [PMID: 29555805 PMCID: PMC5869541 DOI: 10.1098/rsta.2017.0232] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 01/08/2018] [Indexed: 05/29/2023]
Abstract
A Markov flow is a stationary measure, with the associated flows and mean first passage times, for a continuous-time regular jump homogeneous semi-Markov process on a discrete state space. Nodes in the state space can be eliminated to produce a smaller Markov flow which is a factor of the original one. Some improvements to the elimination methods of Wales are given. The main contribution of the paper is to present an alternative, namely a method to aggregate groups of nodes to produce a factor. The method can be iterated to make hierarchical aggregation schemes. The potential benefits are efficient computation, including recomputation to take into account local changes, and insights into the macroscopic behaviour.This article is part of the theme issue 'Hilbert's sixth problem'.
Collapse
|
28
|
Radiation dose management for pediatric cardiac computed tomography: a report from the Image Gently 'Have-A-Heart' campaign. Pediatr Radiol 2018; 48:5-20. [PMID: 29292481 PMCID: PMC6230472 DOI: 10.1007/s00247-017-3991-x] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2017] [Revised: 08/21/2017] [Accepted: 09/12/2017] [Indexed: 12/28/2022]
Abstract
Children with congenital or acquired heart disease can be exposed to relatively high lifetime cumulative doses of ionizing radiation from necessary medical imaging procedures including radiography, fluoroscopic procedures including diagnostic and interventional cardiac catheterizations, electrophysiology examinations, cardiac computed tomography (CT) studies, and nuclear cardiology examinations. Despite the clinical necessity of these imaging studies, the related ionizing radiation exposure could pose an increased lifetime attributable cancer risk. The Image Gently "Have-A-Heart" campaign is promoting the appropriate use of medical imaging studies in children with congenital or acquired heart disease while minimizing radiation exposure. The focus of this manuscript is to provide a comprehensive review of radiation dose management and CT performance in children with congenital or acquired heart disease.
Collapse
|
29
|
Preoperative Use of CT Angiography in Infants With Coarctation of the Aorta. World J Pediatr Congenit Heart Surg 2017; 8:196-202. [DOI: 10.1177/2150135116683929] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Background: Computed tomographic angiography (CTA) and echocardiography (echo) are used preoperatively in coarctation of the aorta to define arch hypoplasia and great vessel branching. We sought to determine differences in quantitative measurements, as well as surgical utility, between modalities. Methods: Infants (less than six months) with both CTA and echo prior to coarctation repair from 2004 to 2013 were included. Measurements were compared and correlated with surgical approach. Three surgeons reviewed de-identified images to predict approach and characterize utility. Computed tomographic angiography radiation dose was calculated. Results: Thirty-three patients were included. No differences existed in arch measurements between echo and CTA ( z-score: −2.59 vs −2.43; P = .47). No differences between modalities were seen for thoracotomy ( z-score: −2.48 [echo] vs −2.31 [CTA]; P = .48) or sternotomy ( z-score: −3.13 [echo] vs −3.08 [CTA]; P = .84). Computed tomographic angiography delineated great vessel branching pattern in two patients with equivocal echo findings ( P = .60). Surgeons rated CTA as far more useful than echo in understanding arch hypoplasia and great vessel branching in cases where CTA was done to resolve anatomical questions that remain after echo evaluation. Two of three surgeons were more likely to choose the surgical approach taken based on CTA (surgeon A, P = .02; surgeon B, P = .01). Radiation dose averaged 2.5 (1.6) mSv and trended down from 2.9 mSv (1.8 mSv; n = 20) to 1.6 mSv (0.5 mSv; n = 7) ( P = .06) with new technology. Conclusion: Although CTA and echo measurements of the aorta do not differ, CTA better delineates branching and surgeons strongly prefer it for three-dimensional arch anatomy. We recommend CTA for patients with anomalous arch branching patterns, diffuse or complex hypoplasia, or unusual arch morphology not fully elucidated by echo.
Collapse
|
30
|
Altered aortic 3D hemodynamics and geometry in pediatric Marfan syndrome patients. J Cardiovasc Magn Reson 2017; 19:30. [PMID: 28302143 PMCID: PMC5356404 DOI: 10.1186/s12968-017-0345-7] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2016] [Accepted: 02/16/2017] [Indexed: 01/16/2023] Open
Abstract
BACKGROUND Blood flow dynamics make it possible to better understand the development of aortopathy and cardiovascular events in patients with Marfan syndrome (MFS). Aortic 3D blood flow characteristics were investigated in relation to aortic geometry in children and adolescents with MFS. METHODS Twenty-five MFS patients (age 15.6 ± 4.0 years; 11 females) and 21 healthy controls (age 16.0 ± 2.6 years; 12 females) underwent magnetic resonance angiography and 4D flow CMR for assessment of thoracic aortic size and 3D blood flow velocities. Data analysis included calculation of aortic diameter and BSA-indexed aortic dimensions (Z-score) along the thoracic aorta, 3D mean systolic wall shear stress (WSSmean) in ten aortic segments and assessment of aortic blood flow patterns. RESULTS Aortic root (root), ascending (AAo) and descending (DAo) aortic size was significantly larger in MFS patients than healthy controls (Root Z-score: 3.56 ± 1.45 vs 0.49 ± 0.78, p < 0.001; AAo Z-score 0.21 ± 0.95 vs -0.54 ± 0.64, p = 0.004; proximal DAo Z-score 2.02 ± 1.60 vs 0.56 ± 0.66, p < 0.001). A regional variation in prevalence and severity of flow patterns (vortex and helix flow patterns) was observed, with the aortic root and the proximal DAo (pDAo) being more frequently affected in MFS. MFS patients had significantly reduced WSSmean in the proximal AAo (pAAo) outer segment (0.65 ± 0.12 vs. 0.73 ± 0.14 Pa, p = 0.029) and pDAo inner segment (0.74 ± 0.17 vs. 0.87 ± 0.21 Pa, p = 0.021), as well as higher WSSmean in the inner segment of the distal AAo (0.94 ± 0.14 vs. 0.84 ± 0.15 Pa, p = 0.036) compared to healthy subjects. An inverse relationship existed between pDAo WSSmean and both pDAo diameter (R = -0.53, p < 0.001) and % diameter change along the pDAo segment (R = -0.64, p < 0.001). CONCLUSIONS MFS children and young adults have altered aortic flow patterns and differences in aortic WSS that were most pronounced in the pAAo and pDAo, segments where aortic dissection or rupture often originate. The presence of vortex flow patterns and abnormal WSS correlated with regional size of the pDAo and are potentially valuable additional markers of disease severity.
Collapse
|
31
|
A comparison of real-time radial GRAPPA and standard cine imaging for the evaluation of cardiac function in children and young adults. J Cardiovasc Magn Reson 2016. [PMCID: PMC5032568 DOI: 10.1186/1532-429x-18-s1-o74] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
32
|
Evaluating the disease progression of pediatric bicuspid aortic valve patients using 4D flow MRI data. J Cardiovasc Magn Reson 2016. [PMCID: PMC5032329 DOI: 10.1186/1532-429x-18-s1-p170] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
33
|
Improved assessment of aortic hemodynamics by k-t accelerated dual-venc 4D flow MRI in pediatric patients. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE 2016. [PMCID: PMC5032482 DOI: 10.1186/1532-429x-18-s1-o96] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
34
|
Progressive Aortic Stenosis in Homozygous Familial Hypercholesterolemia After Liver Transplant. Pediatrics 2016; 138:peds.2016-0740. [PMID: 27940769 DOI: 10.1542/peds.2016-0740] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/28/2016] [Indexed: 11/24/2022] Open
Abstract
Early onset coronary artery disease and aortic calcifications are characteristic features of patients with homozygous familial hypercholesterolemia. Standard medical therapy includes dietary modification, pharmacotherapy, and lipoprotein apheresis to lower serum low-density lipoprotein cholesterol (LDL-C). Liver transplant is a surgical option for the treatment of homozygous familial hypercholesterolemia and can lead to normal cholesterol levels. Vascular calcifications are known to progress despite standard medical therapy and have been reported after liver transplant in the setting of rejection. We present the first report of progressive severe aortic valve stenosis in a patient despite liver transplant with normalization of lipid levels and no history of graft rejection.
Collapse
|
35
|
Evaluation of blood flow distribution asymmetry and vascular geometry in patients with Fontan circulation using 4-D flow MRI. Pediatr Radiol 2016; 46:1507-19. [PMID: 27350377 PMCID: PMC5039076 DOI: 10.1007/s00247-016-3654-3] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2016] [Revised: 05/04/2016] [Accepted: 06/02/2016] [Indexed: 11/26/2022]
Abstract
BACKGROUND Asymmetrical caval to pulmonary blood flow is suspected to cause complications in patients with Fontan circulation. The aim of this study was to test the feasibility of 4-D flow MRI for characterizing the relationship between 3-D blood flow distribution and vascular geometry. OBJECTIVE We hypothesized that both flow distribution and geometry can be calculated with low interobserver variability and will detect a direct relationship between flow distribution and Fontan geometry. MATERIALS AND METHODS Four-dimensional flow MRI was acquired in 10 Fontan patients (age: 16 ± 4 years [mean ± standard deviation], range: 9-21 years). The Fontan connection was isolated by 3-D segmentation to evaluate flow distribution from the inferior vena cava (IVC) and superior vena cava (SVC) to the left and right pulmonary arteries (LPA, RPA) and to characterize geometry (cross-sectional area, caval offset, vessel angle). RESULTS Flow distribution results indicated SVC flow tended toward the RPA while IVC flow was more evenly distributed (SVC to RPA: 78% ± 28 [9-100], IVC to LPA: 54% ± 28 [4-98]). There was a significant relationship between pulmonary artery cross-sectional area and flow distribution (IVC to RPA: R(2)=0.50, P=0.02; SVC to LPA: R(2)=0.81, P=0.0004). Good agreement was found between observers and for flow distribution when compared to net flow values. CONCLUSION Four-dimensional flow MRI was able to detect relationships between flow distribution and vessel geometry. Future studies are warranted to investigate the potential of patient specific hemodynamic analysis to improve diagnostic capability.
Collapse
|
36
|
Hemodynamic evaluation in patients with transposition of the great arteries after the arterial switch operation: 4D flow and 2D phase contrast cardiovascular magnetic resonance compared with Doppler echocardiography. J Cardiovasc Magn Reson 2016; 18:59. [PMID: 27659876 PMCID: PMC5034650 DOI: 10.1186/s12968-016-0276-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2016] [Accepted: 08/24/2016] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Peak velocity measurements are used to evaluate the significance of stenosis in patients with transposition of the great arteries after the arterial switch operation (TGA after ASO). 4D flow cardiovascular magnetic resonance (CMR) provides 3-directional velocity encoding and full volumetric coverage of the great arteries and may thus improve the hemodynamic evaluation in these patients. The aim of this study was to compare peak velocities measured by 4D flow CMR with 2D phase contrast (PC) CMR and the gold standard Doppler echocardiography (echo) in patients with TGA after ASO. METHODS Nineteen patients (mean age 13 ± 9 years, range 1-25 years) with TGA after ASO who underwent 2D PC CMR and 4D flow CMR were included in this study. Peak velocities were measured with 4D flow CMR in the aorta and pulmonary arteries and compared to peak velocities measured with 2D PC CMR and Doppler echo. 2D PC CMR data were available in the ascending aorta, main, right and left pulmonary arteries (AAO/MPA/RPA/LPA) for 19/18/17/17 scans, respectively, and Doppler echo data were available for 13/9/6/6 scans, respectively. Peak velocities were measured with: 1) a single cross section for 2D PC CMR, 2) velocity maximum intensity projections (MIPs) for 4D flow CMR and 3) Doppler echo. RESULTS Significantly higher peak velocities were found with 4D flow CMR than 2D PC CMR in the AAO (p = 0.003), MPA (p = 0.002) and RPA (p = 0.005) but not in the LPA (p = 0.200). No difference in peak velocity was found between 4D flow CMR and Doppler echo (p > 0.46) or 2D PC CMR and echo (p > 0.11) for all analyzed vessel segments. CONCLUSIONS 4D flow CMR evaluation of patients with TGA after ASO detected higher peak velocities than 2D PC CMR, indicating the potential of 4D flow CMR to provide improved stenosis assessment in these patients.
Collapse
|
37
|
Efficient method for volumetric assessment of peak blood flow velocity using 4D flow MRI. J Magn Reson Imaging 2016; 44:1673-1682. [PMID: 27192153 DOI: 10.1002/jmri.25305] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2016] [Revised: 04/22/2016] [Accepted: 04/25/2016] [Indexed: 12/31/2022] Open
Abstract
PURPOSE To test the feasibility and effectiveness of using maximum intensity plots (MIPs) based on 4D flow magnetic resonance imaging (MRI) velocity data to assess systolic peak velocities in a cohort of bicuspid aortic valve (BAV) patients. MATERIALS AND METHODS 4D flow MRI at 1.5T was performed on 51 BAV patients. MIPs were generated from the 4D flow MRI velocity data and used by two users to determine peak velocities in three regions of interest (ROIs): ascending aorta (AAo), aortic arch, and descending aorta. 4D flow MRI peak velocities in the AAo were compared to peak velocities recorded by 2D phase contrast MRI (2D PCMRI) in a subcohort of 36 patients and by Doppler echocardiography in a subcohort of 34 patients. 4D flow MRI peak velocities recorded by each observer were compared for all ROIs to test for interobserver variability. RESULTS 4D flow MRI recorded significantly higher velocities compared to 2D PCMRI (2.04 ± 0.71 m/s vs. 1.69 ± 0.79 m/s, 17.2% difference, P < 0.001) and similar velocities compared to Doppler echocardiography. There was excellent agreement between the observers, with a mean difference of 0.005 m/s and an intraclass correlation coefficient of 0.98. CONCLUSION 4D flow MRI velocity MIPs allow for efficient measurement of peak velocities in BAV patients with higher accuracy than 2D PCMRI and similar accuracy to Doppler echocardiography. J. Magn. Reson. Imaging 2016;44:1673-1682.
Collapse
|
38
|
Cardiovascular magnetic resonance techniques and findings in children with myocarditis: a multicenter retrospective study. J Cardiovasc Magn Reson 2015; 17:96. [PMID: 26576638 PMCID: PMC4650339 DOI: 10.1186/s12968-015-0201-6] [Citation(s) in RCA: 65] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2015] [Accepted: 11/02/2015] [Indexed: 01/05/2023] Open
Abstract
BACKGROUND Cardiovascular magnetic resonance (CMR) is increasingly used to diagnose myocarditis in adults but its use in children is not well-established. We sought to describe the presentation, CMR protocol and findings, and outcomes in a multicenter cohort of children with myocarditis. METHODS Thirteen hospitals retrospectively identified patients meeting the following inclusion criteria: 1) diagnosis of myocarditis by the managing physicians, 2) age <21 years, 3) CMR examination within 30 days of presentation, and 4) no congenital heart disease. Clinical data and test results, including CMR findings, were abstracted from the medical record. RESULTS For the 143 patients meeting inclusion criteria, the median age was 16.0 years (range, 0.1-20.3) and 139 (97 %) were hospitalized at the time of CMR. The median time from presentation to CMR was 2 days (0-28). The median left ventricular ejection fraction at CMR was 56 % (10-74), with 29 (20 %) below 45 %. The median right ventricular ejection fraction was 54 % (15-72), with 11 (8 %) below 40 %. There was significant variability among centers in the types of tissue characterization techniques employed (p < 0.001). Overall, late gadolinium enhancement (LGE) was used in 100 % of studies, followed by T2-weighted imaging (T2W) in 69 %, first-pass contrast perfusion (FPP) in 48 %, and early gadolinium enhancement (EGE) in 28 %. Abnormalities were most common with LGE (81 %), followed by T2W (74 %), EGE (55 %), and FPP (8 %). The CMR study was interpreted as positive for myocarditis in 117 patients (82 %), negative in 18 (13 %), and equivocal in 7 (5 %), yielding a sensitivity of 82 %. At a median follow-up of 7.1 months (0-87), all patients were alive and 5 had undergone cardiac transplantation. CMR parameters at presentation associated with persistent left ventricular dysfunction were larger left ventricular end-diastolic volume and lower left and right ventricular ejection fraction but not abnormal LGE. CONCLUSIONS Despite significant practice variation in imaging protocol among centers, CMR had a high sensitivity for the diagnosis of myocarditis in pediatric patients. Abnormalities were most often seen with LGE followed by T2W, EGE, and FPP. These findings should be useful in designing future prospective studies.
Collapse
|
39
|
Multi-Detector CTA of Anomalous Right Coronary Artery From Pulmonary Artery in a Five-Month-Old. World J Pediatr Congenit Heart Surg 2015; 6:672-3. [PMID: 26467887 DOI: 10.1177/2150135115593780] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
40
|
Right Ventricular Outflow Tract Growth in Infants With Palliated Tetralogy of Fallot. Ann Thorac Surg 2015; 99:1367-72. [DOI: 10.1016/j.athoracsur.2014.12.031] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2014] [Revised: 12/02/2014] [Accepted: 12/05/2014] [Indexed: 11/27/2022]
|
41
|
Modified single patch: are we still worried about subaortic stenosis? Ann Thorac Surg 2015; 99:1671-5; discussion 1675-6. [PMID: 25825201 DOI: 10.1016/j.athoracsur.2015.01.032] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2014] [Revised: 12/31/2014] [Accepted: 01/06/2015] [Indexed: 10/23/2022]
Abstract
BACKGROUND When the modified single-patch technique for atrioventricular septal defect (AVSD) repair was introduced by Dr Benson Wilcox, there was concern that these patients might be at risk for late subaortic stenosis and left ventricular outflow tract obstruction (LVOTO). This review evaluated our modified single-patch population for LVOTO in the postoperative period. METHODS Between January 2000 and 2013, 77 infants underwent AVSD repair with a modified single-patch technique. Median age was 4.2 months, and median weight was 5 kg. Eight patients had a prior repair of coarctation of the aorta via left thoracotomy in the newborn period. RESULTS The median hospital stay was 10 days. No patient required a pacemaker. The mean and median follow-up times were 4.6 and 3.7 years, respectively. Only 2 patients (2.5%) required reoperation for LVOTO; both had prior repair of coarctation of the aorta (2 of 8 vs 0 of 69, p = 0.01). A discrete fibrous subaortic membrane developed in the first patient that required resection at 3 and 7 years after repair. The other patient had LVOTO from accessory chordae of the left atrioventricular valve and required mitral valve replacement 5 months after repair. One early death occurred at 4 months postoperatively due to liver failure related to hyperalimentation. CONCLUSIONS At intermediate term follow-up, LVOTO does not appear to be a significant postoperative issue after modified single-patch repair of AVSD. Coarctation of the aorta was the most significant predictor of late LVOTO after repair of AVSD with the modified single-patch technique.
Collapse
|
42
|
Thoracic aorta 3D hemodynamics in pediatric and young adult patients with bicuspid aortic valve. J Magn Reson Imaging 2015; 42:954-63. [PMID: 25644073 DOI: 10.1002/jmri.24847] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2014] [Revised: 12/17/2014] [Accepted: 12/18/2014] [Indexed: 11/07/2022] Open
Abstract
BACKGROUND To evaluate the 3D hemodynamics in the thoracic aorta of pediatric and young adult bicuspid aortic valve (BAV) patients. METHODS 4D flow MRI was performed in 30 pediatric and young adult BAV patients (age: 13.9 ± 4.4 (range: [3.4, 20.7]) years old, M:F = 17:13) as part of this Institutional Review Board-approved study. Nomogram-based aortic root Z-scores were calculated to assess aortic dilatation and degree of aortic stenosis (AS) severity was assessed on MRI. Data analysis included calculation of time-averaged systolic 3D wall shear stress (WSSsys ) along the entire aorta wall, and regional quantification of maximum and mean WSSsys and peak systolic velocity (velsys ) in the ascending aorta (AAo), arch, and descending aorta (DAo). The 4D flow MRI AAo velsys was also compared with echocardiography peak velocity measurements. RESULTS There was a positive correlation with both mean and max AAo WSSsys and peak AAo velsys (mean: r = 0.84, P < 0.001, max: r = 0.94, P < 0.001) and AS (mean: rS = 0.43, P = 0.02, max: rS = 0.70, P < 0.001). AAo peak velocity was significantly higher when measured with echo compared with 4D flow MRI (2.1 ± 0.98 m/s versus 1.27 ± 0.49 m/s, P < 0.001). CONCLUSION In pediatric and young adult patients with BAV, AS and peak ascending aorta velocity are associated with increased AAo WSS, while aortic dilation, age, and body surface area do not significantly impact AAo hemodynamics. Prospective studies are required to establish the role of WSS as a risk-stratification tool in these patients.
Collapse
|
43
|
Right pulmonary artery to left atrial fistula in a neonate: case report and review of the literature. World J Pediatr Congenit Heart Surg 2015; 5:306-10. [PMID: 24668980 DOI: 10.1177/2150135113508562] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
A communication between the right pulmonary artery (RPA) and the left atrium is a rare congenital anomaly that presents with cyanosis and heart failure. We describe the surgical repair of an RPA to left atrial fistula using cardiopulmonary bypass in a neonate. Advanced imaging (computed tomography scan) guided the surgical approach. Although previous reports have associated a patent ductus arteriosus with high neonatal mortality, in our case, the ductus arteriosus was actually important for maintaining enough total pulmonary blood flow.
Collapse
|
44
|
Bicuspid aortic valve phenotype and aortopathy: nomenclature and role of aortic hemodynamics. JACC Cardiovasc Imaging 2014; 6:921. [PMID: 23948381 DOI: 10.1016/j.jcmg.2013.03.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2013] [Accepted: 03/29/2013] [Indexed: 01/29/2023]
|
45
|
Enhanced segmentation improves 4D blood flow quantification in patients with tetralogy of Fallot and pulmonary regurgitation. J Cardiovasc Magn Reson 2014. [PMCID: PMC4044186 DOI: 10.1186/1532-429x-16-s1-p118] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
46
|
Assessment of myocardial motion in children and young adults using High-temporal resolution MR tissue phase mapping. J Cardiovasc Magn Reson 2014. [PMCID: PMC4045725 DOI: 10.1186/1532-429x-16-s1-p328] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
47
|
Comparison of 4D flow and 2D PC MRI blood flow quantification in children and young adults with congenital heart disease. J Cardiovasc Magn Reson 2013. [PMCID: PMC3559415 DOI: 10.1186/1532-429x-15-s1-e90] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
48
|
Aortic coarctation augments changes in thoracic aortic hemodynamics in pediatric and young adult patients with bicuspid aortic valve. J Cardiovasc Magn Reson 2013. [PMCID: PMC3559987 DOI: 10.1186/1532-429x-15-s1-p300] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
49
|
In vivo quantification of blood mixing in single ventricle patients with Fontan circulation using 4D flow MRI. J Cardiovasc Magn Reson 2013. [PMCID: PMC3559408 DOI: 10.1186/1532-429x-15-s1-e88] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
50
|
4-dimensional magnetic resonance imaging of the levoatriocardinal vein. J Am Coll Cardiol 2012; 60:1291. [PMID: 23017534 PMCID: PMC5096731 DOI: 10.1016/j.jacc.2012.01.084] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2012] [Accepted: 01/31/2012] [Indexed: 11/23/2022]
|