1
|
Ocular surface information seen from the somatosensory thalamus and cortex. J Physiol 2024; 602:1405-1426. [PMID: 38457332 DOI: 10.1113/jp285008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 02/20/2024] [Indexed: 03/10/2024] Open
Abstract
Ocular Surface (OS) somatosensory innervation detects external stimuli producing perceptions, such as pain or dryness, the most relevant symptoms in many OS pathologies. Nevertheless, little is known about the central nervous system circuits involved in these perceptions, and how they integrate multimodal inputs in general. Here, we aim to describe the thalamic and cortical activity in response to OS stimulation of different modalities. Electrophysiological extracellular recordings in anaesthetized rats were used to record neural activity, while saline drops at different temperatures were applied to stimulate the OS. Neurons were recorded in the ophthalmic branch of the trigeminal ganglion (TG, 49 units), the thalamic VPM-POm nuclei representing the face (Th, 69 units) and the primary somatosensory cortex (S1, 101 units). The precise locations for Th and S1 neurons receiving OS information are reported here for the first time. Interestingly, all recorded nuclei encode modality both at the single neuron and population levels, with noxious stimulation producing a qualitatively different activity profile from other modalities. Moreover, neurons responding to new combinations of stimulus modalities not present in the peripheral TG subsequently appear in Th and S1, being organized in space through the formation of clusters. Besides, neurons that present higher multimodality display higher spontaneous activity. These results constitute the first anatomical and functional characterization of the thalamocortical representation of the OS. Furthermore, they provide insight into how information from different modalities gets integrated from the peripheral nervous system into the complex cortical networks of the brain. KEY POINTS: Anatomical location of thalamic and cortical ocular surface representation. Thalamic and cortical neuronal responses to multimodal stimulation of the ocular surface. Increasing functional complexity along trigeminal neuroaxis. Proposal of a new perspective on how peripheral activity shapes central nervous system function.
Collapse
|
2
|
Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users. Invest Ophthalmol Vis Sci 2023; 64:12. [PMID: 37938935 PMCID: PMC10637199 DOI: 10.1167/iovs.64.14.12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Accepted: 10/18/2023] [Indexed: 11/10/2023] Open
Abstract
Purpose The purpose of this study was to analyze the differences in corneal sensory nerve functionality in young asymptomatic (CL-A) and symptomatic (CL-S) contact lens (CL) users. Methods CL wearers (23.8 ± 1.0 years, n = 31) were classified as CL-S with an Ocular Surface Disease Index (OSDI) ≥ 13 (n = 14) or CL-A. Users of eye glasses (EG; 24.5 ± 0.8 years, n = 29) with OSDI < 13 participated as controls. The sensations evoked by mechanical, chemical (gas esthesiometer), and cold (4°C saline drops) stimuli were measured using the Visual Analogue Scales (VASs). Moreover, tear volume, tear break up time (TBUT), blinking frequency (BF), and ocular surface temperature (OST; IR thermography) were also measured. Results Mechanical and chemical stimuli produced similar scores in the CL-A and EG participants, although the CL-A subjects referred to stronger irritation (p < 0.05). Likewise, the VAS intensity in response to cold stimuli did not differ between CL-A and EG subjects, while the ability to detect cold was significantly worse in CL-S users (p < 0.05). CL-A users had a similar tear volume, a higher BF (p < 0.01) and shorter TBUT (p < 0.001) to EG wearers, and blinking and TBUT were also altered significantly in CL-S users (p < 0.01). Interestingly, the OST was significantly lower in CL-A users (p < 0.05) than in EG wearers, but not in CL-S users. Conclusions Using CLs modifies corneal sensitivity, blinking and tearing in young volunteers. Even if they have yet to develop clinical signs of inflammation, they display changes in corneal sensitivity consistent with the sensitization of corneal nociceptors and the inhibition cold thermoreceptors, phenomena that occur under inflammatory conditions. The differences in corneal sensitivity and OST between CL-A and CL-S users could reflect the extent of nerve damage and inflammation at the ocular surface.
Collapse
|
3
|
Cyclosporine A Decreases Dryness-Induced Hyperexcitability of Corneal Cold-Sensitive Nerve Terminals. Int J Mol Sci 2023; 24:13025. [PMID: 37629206 PMCID: PMC10455570 DOI: 10.3390/ijms241613025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 08/09/2023] [Accepted: 08/17/2023] [Indexed: 08/27/2023] Open
Abstract
Cyclosporine A (CsA) is used for the treatment of dry eye (DE) with good clinical results, improving tear secretion and decreasing subjective symptoms. These effects are attributed to the improved tear film dynamics, but there are no data on the effect of CsA on the abnormal sensory nerve activity characteristic in DE. Our purpose was to evaluate the CsA effect on the enhanced activity of corneal cold thermoreceptors in a tear-deficient DE animal model using in vitro extracellular recording of cold thermoreceptors nerve terminal impulses (NTIs) before and in the presence of CsA. NTI shape was also analyzed. Blinking frequency and tearing rate were also measured in awake animals before and after topical CsA. CsA increased the tearing and blinking of treated animals. CsA significantly decreased the peak response to cold of cold thermoreceptors. Neither their spontaneous NTIs discharge rate nor their cooling threshold were modified. CsA also seemed to reverse some of the changes in NTI shape induced by tear deficiency. These data suggest that, at least in part, the beneficial clinical effects of CsA in DE can be attributed to a direct effect on sensory nerve endings, although the precise mechanisms underlying this effect need further studies to be fully clarified.
Collapse
|
4
|
The Contribution of TRPA1 to Corneal Thermosensitivity and Blink Regulation in Young and Aged Mice. Int J Mol Sci 2023; 24:12620. [PMID: 37628800 PMCID: PMC10454529 DOI: 10.3390/ijms241612620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 07/31/2023] [Accepted: 08/04/2023] [Indexed: 08/27/2023] Open
Abstract
The role of TRPA1 in the thermosensitivity of the corneal cold thermoreceptor nerve endings was studied in young and aged mice. The contribution of the TRPA1-dependent activity to basal tearing and thermally-evoked blink was also explored. The corneal cold thermoreceptors' activity was recorded extracellularly in young (5-month-old) and aged (18-month-old) C57BL/6WT (WT) and TRPA1-/- knockout (TRPA1-KO) mice at basal temperature (34 °C) and during cooling (15 °C) and heating (45 °C) ramps. The blink response to cold and heat stimulation of the ocular surface and the basal tearing rate were also measured in young animals using orbicularis oculi muscle electromyography (OOemg) and phenol red threads, respectively. The background activity at 34 °C and the cooling- and heating-evoked responses of the cold thermoreceptors were similar in WT and TRPA1-KO animals, no matter the age. Similar to the aged WT mice, in the young and aged TRPA1-KO mice, most of the cold thermoreceptors presented low frequency background activity, a low cooling threshold, and a sluggish response to heating. The amplitude and duration of the OOemg signals correlated with the magnitude of the induced thermal change in the WT but not in the TRPA1-KO mice. The basal tearing was similar in the TRPA1-KO and WT mice. The electrophysiological data suggest that the TRPA1-dependent nerve activity, which declines with age, contributes to detecting the warming of the ocular surface and also to integrating the thermally-evoked reflex blink.
Collapse
|
5
|
Maximal tear secretion evoked by controlled stimulation of corneal sensory nerves in healthy individuals and dry eye subjects. Ocul Surf 2023; 27:80-88. [PMID: 36396021 DOI: 10.1016/j.jtos.2022.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Revised: 11/10/2022] [Accepted: 11/10/2022] [Indexed: 11/16/2022]
Abstract
PURPOSE To measure, the tear flow changes evoked in healthy subjects and dry eye disease (DED) patients by controlled sensory stimulation of the eye surface with i-Onion™, a new stimulation device. METHODS Sensory corneal nerves were stimulated with an instrument (i-Onion™) that ejects puffs of CO2 gas (99.9%) at 200 ml·min-1 for 3s, delivered 5 mm from the cornea. Using Schirmer test strips, tear volumes were measured over 3 min in the cornea of one eye before (basal tear volume -BTV) and in the other eye after stimulation of the sensory nerves with CO2 (stimulated tear volume -STV). These measurements were obtained from a control group of adults of either sex (17 students aged 20-30 and 29 subjects without signs of dry eye aged 25-61), a cohort of DED patients (aged 34-75) that included 12 asymptomatic, suspected DED subjects (Schirmer <7 mm and/or TBUT <10s), and 30 Sjögren's syndrome (SS) patients. RESULTS CO2 stimulation significantly increased the tear volume (BTV = 14.6 ± 1.0 mm, STV = 19.0 ± 1.1 mm: n = 46) in 78% of control subjects, reflecting a mean tear reserve volume (TRV = STV-BTV) of 4.4 ± 0.8 mm. Individual differences were wide, and while no increase in reflex tearing was evoked in 30% of subjects with a BTV >10 mm, the remaining 70% responded vigorously to stimulation, even those with a BTV >18 mm. Asymptomatic DED subjects displayed weaker responses to CO2 stimulation, with lower STVs. Both the BTV and STV of SS patients were low, significantly below those of the healthy controls. CONCLUSIONS Measuring the rise in reflex tearing volume evoked by controlled corneal stimulation provides objective information about the tear glands' secretory capacity in health and disease.
Collapse
|
6
|
Validation of the
CD11c‐DTR
transgenic mouse as a model to study neuroimmune interactions in the cornea. Acta Ophthalmol 2022. [DOI: 10.1111/j.1755-3768.2022.0596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
7
|
Effects of contact lens wearing on corneal sensitivity and reflex functions. Acta Ophthalmol 2022. [DOI: 10.1111/j.1755-3768.2022.0605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
8
|
Unilateral corneal insult also alters sensory nerve activity in the contralateral eye. Acta Ophthalmol 2022. [DOI: 10.1111/j.1755-3768.2022.15376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/11/2023]
|
9
|
An Experimental Model of Neuro-Immune Interactions in the Eye: Corneal Sensory Nerves and Resident Dendritic Cells. Int J Mol Sci 2022; 23:ijms23062997. [PMID: 35328417 PMCID: PMC8951464 DOI: 10.3390/ijms23062997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 02/28/2022] [Accepted: 03/04/2022] [Indexed: 12/04/2022] Open
Abstract
The cornea is an avascular connective tissue that is crucial, not only as the primary barrier of the eye but also as a proper transparent refractive structure. Corneal transparency is necessary for vision and is the result of several factors, including its highly organized structure, the physiology of its few cellular components, the lack of myelinated nerves (although it is extremely innervated), the tightly controlled hydration state, and the absence of blood and lymphatic vessels in healthy conditions, among others. The avascular, immune-privileged tissue of the cornea is an ideal model to study the interactions between its well-characterized and dense sensory nerves (easily accessible for both focal electrophysiological recording and morphological studies) and the low number of resident immune cell types, distinguished from those cells migrating from blood vessels. This paper presents an overview of the corneal structure and innervation, the resident dendritic cell (DC) subpopulations present in the cornea, their distribution in relation to corneal nerves, and their role in ocular inflammatory diseases. A mouse model in which sensory axons are constitutively labeled with tdTomato and DCs with green fluorescent protein (GFP) allows further analysis of the neuro-immune crosstalk under inflammatory and steady-state conditions of the eye.
Collapse
|
10
|
Editorial: Sensory Abnormalities and Primary Sensory Neurons. Front Cell Neurosci 2022; 16:852614. [PMID: 35185476 PMCID: PMC8854170 DOI: 10.3389/fncel.2022.852614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Accepted: 01/13/2022] [Indexed: 11/13/2022] Open
|
11
|
|
12
|
Unilateral Corneal Insult Also Alters Sensory Nerve Activity in the Contralateral Eye. Front Med (Lausanne) 2021; 8:767967. [PMID: 34869482 PMCID: PMC8634144 DOI: 10.3389/fmed.2021.767967] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 10/11/2021] [Indexed: 01/21/2023] Open
Abstract
After the unilateral inflammation or nerve lesion of the ocular surface, the ipsilateral corneal sensory nerve activity is activated and sensitized, evoking ocular discomfort, irritation, and pain referred to the affected eye. Nonetheless, some patients with unilateral ocular inflammation, infection, or surgery also reported discomfort and pain in the contralateral eye. We explored the possibility that such altered sensations in the non-affected eye are due to the changes in their corneal sensory nerve activity in the contralateral, not directly affected eye. To test that hypothesis, we recorded the impulse activity of the corneal mechano- and polymodal nociceptor and cold thermoreceptor nerve terminals in both eyes of guinea pigs, subjected unilaterally to three different experimental conditions (UV-induced photokeratitis, microkeratome corneal surgery, and chronic tear deficiency caused by removal of the main lacrimal gland), and in eyes of naïve animals ex vivo. Overall, after unilateral eye damage, the corneal sensory nerve activity appeared to be also altered in the contralateral eye. Compared with the naïve guinea pigs, animals with unilateral UV-induced mild corneal inflammation, showed on both eyes an inhibition of the spontaneous and stimulus-evoked activity of cold thermoreceptors, and increased activity in nociceptors affecting both the ipsilateral and the contralateral eye. Unilateral microkeratome surgery affected the activity of nociceptors mostly, inducing sensitization in both eyes. The removal of the main lacrimal gland reduced tear volume and increased the cold thermoreceptor activity in both eyes. This is the first direct demonstration that unilateral corneal nerve lesion, especially ocular surface inflammation, functionally affects the activity of the different types of corneal sensory nerves in both the ipsilateral and contralateral eyes. The mechanisms underlying the contralateral affectation of sensory nerves remain to be determined, although available data support the involvement of neuroimmune interactions. The parallel alteration of nerve activity in contralateral eyes has two main implications: a) in the experimental design of both preclinical and clinical studies, where the contralateral eyes cannot be considered as a control; and, b) in the clinical practice, where clinicians must consider the convenience of treating both eyes of patients with unilateral ocular conditions to avoid pain and secondary undesirable effects in the fellow eye.
Collapse
|
13
|
Deciphering the Action of Perfluorohexyloctane Eye Drops to Reduce Ocular Discomfort and Pain. Front Med (Lausanne) 2021; 8:709712. [PMID: 34765614 PMCID: PMC8577568 DOI: 10.3389/fmed.2021.709712] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Accepted: 09/28/2021] [Indexed: 12/24/2022] Open
Abstract
Perfluorohexyloctane (F6H8) eyedrops have been recently introduced in Europe as a product to treat dry eye disease, based on its ability to reduce tear film instability in Meibomian gland dysfunction and evaporative dry eye disease, although its mechanism of action is still unknown. In the present pilot study, we evaluated the effects of the ocular instillation of a single drop of commercial F6H8 eyedrops in 20 healthy humans (9 women/11 men), measuring: (a) Corneal surface temperature (CST) from infrared video images; (b) tear volume using phenol red threads; (c) blinking frequency; and (d) ocular surface sensations (cold, dryness, pricking, foreign body, burning, itching, gritty, eye fatigue, watering eyes, and light-evoked discomfort sensations; scored using 10 cm Visual Analog Scales), before and 5–60 min after F6H8 or saline treatment. CST decreased and tearing and blinking frequency increased significantly after F6H8 but not after saline solution. When applied unilaterally, CST decreased only in the F6H8-treated eye. No sensations were evoked after F6H8 or saline. The corneal surface temperature reduction produced by topical F6H8 does not evoke conscious ocular sensations but is sufficient to increase the activity of corneal cold thermoreceptors, leading to an increased reflex lacrimation and blinking that may relieve dry eye condition thus reducing ocular discomfort and pain.
Collapse
|
14
|
Contact lens and eye glass wearers with and witouth ocular symptoms: differences in corneal sensitivity, blinking, tearing and corneal surface temperature. Acta Ophthalmol 2019. [DOI: 10.1111/j.1755-3768.2019.5459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
15
|
Ocular thermography in ocular inflammation and dry eye. Acta Ophthalmol 2019. [DOI: 10.1111/j.1755-3768.2019.5004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
16
|
The role of brain biopsy in the clinical management of HIV-related focal brain lesions. HIV Med 2018; 19:673-678. [PMID: 30004180 DOI: 10.1111/hiv.12646] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/23/2018] [Indexed: 12/01/2022]
Abstract
OBJECTIVES Up to 20% of HIV-related focal brain lesion (FBL) diagnoses cannot be determined without invasive procedures. In such cases, brain biopsy is an important step in the evaluation algorithm. The aims of this study were to describe the clinical outcomes of patients with FBL, the proportion of diagnoses confirmed by brain biopsies and their aetiologies, and to analyse the proportion of patients in whom the biopsy motivated a change in therapeutic management. METHODS A retrospective cohort study was performed. The data from clinical records of patients with HIV-related FBL admitted between January 2005 and December 2015 were reviewed. RESULTS A total of 137 patients were included in the study. The median age was 39 years [interquartile range (IQR) 33-44.5 years]. The median CD4 count was 54 cells/μL (IQR 21-124 cells/μL). Cerebral brain biopsy was performed in 21.16% of patients (29 of 137); 68.9% of these individuals (20 of 29) were diagnosed by histology, with results of central nervous system (CNS) lymphoma in 20.6% (six of 29), progressive multifocal leucoencephalopathy in 6.8% (two of 29), toxoplasmosis in 6.8% (two of 29), tuberculoma in 6.8% (two of 29), and other diagnoses in 27.6% (eight of 29). In nine patients, the histology was nonspecific. In 75.8% of patients (22 of 29), the result of the biopsy led to a change in the therapeutic management. We did not observe higher rates of mortality related to the procedure. Overall mortality at 30 and 90 days was similar in patients who were and were not biopsied. CONCLUSIONS In this retrospective cohort study, cerebral biopsy was associated with significant adjustments in therapeutic management for a high percentage of patients.
Collapse
|
17
|
The Effect of Tear Supplementation with 0.15% Preservative-Free Zinc-Hyaluronate on Ocular Surface Sensations in Patients with Dry Eye. J Ocul Pharmacol Ther 2017; 33:487-492. [DOI: 10.1089/jop.2016.0194] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
18
|
Lacosamide diminishes dryness-induced hyperexcitability of corneal cold sensitive nerve terminals. Eur J Pharmacol 2016; 787:2-8. [PMID: 27263827 DOI: 10.1016/j.ejphar.2016.05.044] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2016] [Revised: 05/26/2016] [Accepted: 05/31/2016] [Indexed: 10/21/2022]
Abstract
Lacosamide is an anti-epileptic drug that is also used for the treatment of painful diabetic neuropathy acting through voltage-gated sodium channels. The aim of this work was to evaluate the effects of acute application of lacosamide on the electrical activity of corneal cold nerve terminals in lacrimo-deficient guinea pigs. Four weeks after unilateral surgical removal of the main lachrimal gland in guinea pigs, corneas were excised and superfused in vitro at 34°C for extracellular electrophysiological recording of nerve terminal impulse activity of cold thermosensitive nerve terminals. The characteristics of the spontaneous and the stimulus-evoked (cooling ramps from 34°C to 15°C) activity before and in presence of lacosamide 100µM and lidocaine 100µM were compared. Cold nerve terminals (n=34) recorded from dry eye corneas showed significantly enhanced spontaneous activity (8.0±1.1 vs. 5.2±0.7imp/s; P<0.05) and cold response (21.2±1.7 vs. 16.8±1.3imp/s; P<0.05) as well as reduced cold threshold (1.5±0.1 vs. 2.8±0.2 Δ°C; P<0.05) to cooling ramps compared to terminals (n=58) from control animals. Both lacosamide and lidocaine decreased spontaneous activity and peak response to cooling ramps significantly (P<0.05). Temperature threshold was increased by the addition of lidocaine (P<0.05) but not lacosamide (P>0.05) to the irrigation fluid. In summary, the application of lacosamide results in a significant decrease of the augmented spontaneous activity and responsiveness to cold of corneal sensory nerves from tear-deficient animals. Based on these promising results we speculate that lacosamide might be used to reduce the hyperexcitability of corneal cold receptors caused by prolonged ocular surface dryness due to hyposecretory or evaporative dry eye disease.
Collapse
|
19
|
Using chromosomal data in the phylogenetic and molecular dating framework: karyotype evolution and diversification in Nierembergia (Solanaceae) influenced by historical changes in sea level. PLANT BIOLOGY (STUTTGART, GERMANY) 2016; 18:514-526. [PMID: 26718314 DOI: 10.1111/plb.12430] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2015] [Accepted: 12/22/2015] [Indexed: 06/05/2023]
Abstract
Karyotype data within a phylogenetic framework and molecular dating were used to examine chromosome evolution in Nierembergia and to infer how geological or climatic processes have influenced in the diversification of this solanaceous genus native to South America and Mexico. Despite the numerous studies comparing karyotype features across species, including the use of molecular phylogenies, to date relatively few studies have used formal comparative methods to elucidate chromosomal evolution, especially to reconstruct the whole ancestral karyotypes. Here, we mapped on the Nierembergia phylogeny one complete set of chromosomal data obtained by conventional staining, AgNOR-, C- and fluorescent chromosome banding, and fluorescent in situ hybridisation. In addition, we used a Bayesian molecular relaxed clock to estimate divergence times between species. Nierembergia showed two major divergent clades: a mountainous species group with symmetrical karyotypes, large chromosomes, only one nucleolar organising region (NOR) and without centromeric heterochromatin, and a lowland species group with asymmetrical karyotypes, small chromosomes, two chromosomes pairs with NORs and centromeric heterochromatin bands. Molecular dating on the DNA phylogeny revealed that both groups diverged during Late Miocene, when Atlantic marine ingressions, called the 'Paranense Sea', probably forced the ancestors of these species to find refuge in unflooded areas for about 2 Myr. This split agrees with an increased asymmetry and heterochromatin amount, and decrease in karyotype length and chromosome size. Thus, when the two Nierembergia ancestral lineages were isolated, major divergences occurred in chromosomal evolution, and then each lineage underwent speciation separately, with relatively minor changes in chromosomal characteristics.
Collapse
|
20
|
Abnormal activity of corneal cold thermoreceptors underlies the unpleasant sensations in dry eye disease. Pain 2016; 157:399-417. [PMID: 26675826 PMCID: PMC4733818 DOI: 10.1097/j.pain.0000000000000455] [Citation(s) in RCA: 79] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2015] [Revised: 10/09/2015] [Accepted: 10/28/2015] [Indexed: 12/23/2022]
Abstract
Dry eye disease (DED) affects >10% of the population worldwide, and it provokes an unpleasant sensation of ocular dryness, whose underlying neural mechanisms remain unknown. Removal of the main lachrymal gland in guinea pigs caused long-term reduction of basal tearing accompanied by changes in the architecture and density of subbasal corneal nerves and epithelial terminals. After 4 weeks, ongoing impulse activity and responses to cooling of corneal cold thermoreceptor endings were enhanced. Menthol (200 μM) first excited and then inactivated this augmented spontaneous and cold-evoked activity. Comparatively, corneal polymodal nociceptors of tear-deficient eyes remained silent and exhibited only a mild sensitization to acidic stimulation, whereas mechanonociceptors were not affected. Dryness-induced changes in peripheral cold thermoreceptor responsiveness developed in parallel with a progressive excitability enhancement of corneal cold trigeminal ganglion neurons, primarily due to an increase of sodium currents and a decrease of potassium currents. In corneal polymodal nociceptor neurons, sodium currents were enhanced whereas potassium currents remain unaltered. In healthy humans, exposure of the eye surface to menthol vapors or to cold air currents evoked unpleasant sensations accompanied by increased blinking frequency that we attributed to cold thermoreceptor stimulation. Notably, stimulation with menthol reduced the ongoing background discomfort of patients with DED, conceivably due to use-dependent inactivation of cold thermoreceptors. Together, these data indicate that cold thermoreceptors contribute importantly to the detection and signaling of ocular surface wetness, and develop under chronic eye dryness conditions an injury-evoked neuropathic firing that seems to underlie the unpleasant sensations experienced by patients with DED.
Collapse
|
21
|
Corneal Sensitivity and Dry Eye Symptoms in Patients with Keratoconus. PLoS One 2015; 10:e0141621. [PMID: 26495846 PMCID: PMC4619831 DOI: 10.1371/journal.pone.0141621] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2015] [Accepted: 10/09/2015] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To investigate corneal sensitivity to selective mechanical, chemical, and thermal stimulation and to evaluate their relation to dry eye symptoms in patients with keratoconus. METHODS Corneal sensitivity to mechanical, chemical, and thermal thresholds were determined using a gas esthesiometer in 19 patients with keratoconus (KC group) and in 20 age-matched healthy subjects (control group). Tear film dynamics was assessed by Schirmer I test and by the non-invasive tear film breakup time (NI-BUT). All eyes were examined with a rotating Scheimpflug camera to assess keratoconus severity. RESULTS KC patients had significatly decreased tear secretion and significantly higher ocular surface disease index (OSDI) scores compared to controls (5.3±2.2 vs. 13.2±2.0 mm and 26.8±15.8 vs. 8.1±2.3; p<0.001). There was no significant difference in NI-BUT between the two groups (KC: 9.8±4.8 vs. control: 10.7±3.8; p>0.05). The mean threshold for selective mechanical (KC: 139.2±25.8 vs. control: 109.1±24.0 ml/min), chemical (KC: 39.4±3.9 vs. control: 35.2±1.9%CO2), heat (KC: 0.91±0.32 vs. control: 0.54±0.26 Δ°C) and cold (KC: 1.28±0.27 vs. control: 0.98±0.25 Δ°C) stimulation in the KC patients were significantly higher than in the control subjects (p<0.001, for all parameters). No correlation was found between age and mechanical, chemical, heat or cold thresholds in the patients with KC (p>0.05), whereas in the control subjects both mechanical (r = 0.52, p = 0.02), chemical (r = 0.47, p = 0.04), heat (r = 0.26, p = 0.04) and cold threshold (r = 0.40, p = 0.03) increased with age. In the KC group, neither corneal thickness nor tear flow, NI-BUT or OSDI correlated significantly with mechanical, chemical, heat or cold thresholds (p>0.05 for all variables). CONCLUSIONS Corneal sensitivity to different types of stimuli is decreased in patients with keratoconus independently of age and disease severity. The reduction of the sensory input from corneal nerves may contribute to the onset of unpleasant sensations in these patients and might lead to the impaired tear film dynamics.
Collapse
|
22
|
The Effect of Tear Supplementation on Ocular Surface Sensations during the Interblink Interval in Patients with Dry Eye. PLoS One 2015; 10:e0135629. [PMID: 26302222 PMCID: PMC4547761 DOI: 10.1371/journal.pone.0135629] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2015] [Accepted: 07/24/2015] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To investigate the characteristics of ocular surface sensations and corneal sensitivity during the interblink interval before and after tear supplementation in dry eye patients. METHODS Twenty subjects (41.88±14.37 years) with dry eye symptoms were included in the dry eye group. Fourteen subjects (39.13±11.27 years) without any clinical signs and/or symptoms of dry eye were included in the control group. Tear film dynamics was assessed by non-invasive tear film breakup time (NI-BUT) in parallel with continuous recordings of ocular sensations during forced blinking. Corneal sensitivity to selective stimulation of corneal mechano-, cold and chemical receptors was assessed using a gas esthesiometer. All the measurements were made before and 5 min after saline and hydroxypropyl-guar (HP-guar) drops. RESULTS In dry eye patients the intensity of irritation increased rapidly after the last blink during forced blinking, while in controls there was no alteration in the intensity during the first 10 sec followed by an exponential increase. Irritation scores were significantly higher in dry eye patients throughout the entire interblink interval compared to controls (p<0.004). NI-BUT significantly increased after HP-guar (p = 0.003) but not after saline drops (p = 0.14). In both groups, either after saline or HP-guar the shape of symptom intensity curves remained the same with significantly lower irritation scores (p<0.004), however after HP-guar the decrease was significantly more pronounced (p<0.004). Corneal sensitivity to selective mechanical, cold and chemical stimulation decreased significantly in both groups after HP-guar (p<0.05), but not after saline drops (p>0.05). CONCLUSION Ocular surface irritation responses due to tear film drying are considerably increased in dry eye patients compared to normal subjects. Although tear supplementation improves the protective tear film layer, and thus reduce unpleasant sensory responses, the rapid rise in discomfort is still maintained and might be responsible for the remaining complaints of dry eye patients despite the treatment.
Collapse
|
23
|
Abstract
Eye pain is an unpleasant sensory and emotional experience including sensory-discriminative, emotional, cognitive, and behavioral components and supported by distinct, interconnected peripheral and central nervous system elements. Normal or physiological pain results of the stimulation by noxious stimuli of sensory axons of trigeminal ganglion (TG) neurons innervating the eye. These are functionally heterogeneous. Mechano-nociceptors are only excited by noxious mechanical forces. Polymodal nociceptors also respond to heat, exogenous irritants, and endogenous inflammatory mediators, whereas cold thermoreceptors detect moderate temperature changes. Their distinct sensitivity to stimulating forces is determined by the expression of specific classes of ion channels: Piezo2 for mechanical forces, TRPV1 and TRPA1 for heat and chemical agents, and TRPM8 for cold. Pricking pain is evoked by mechano-nociceptors, while polymodal nociceptors are responsible of burning and stinging eye pain; sensations of dryness appear to be mainly evoked by cold thermoreceptors. Mediators released by local inflammation, increase the excitability of eye polymodal nociceptors causing their sensitization and the augmented pain sensations. During chronic inflammation, additional, long-lasting changes in the expression and function of stimulus-transducing and voltage-sensitive ion channels develop, thereby altering polymodal terminal's excitability and evoking chronic inflammatory pain. When trauma, infections, or metabolic processes directly damage eye nerve terminals, these display aberrant impulse firing due to an abnormal expression of transducing and excitability-modulating ion channels. This malfunction evokes 'neuropathic pain' which may also result from abnormal function of higher brain structures where ocular TG neurons project. Eye diseases or ocular surface surgery cause different levels of inflammation and/or nerve injury, which in turn activate sensory fibers of the eye in a variable degree. When inflammation dominates (allergic or actinic kerato-conjunctivitis), polymodal nociceptors are primarily stimulated and sensitized, causing pain. In uncomplicated photorefractive surgery and moderate dry eye, cold thermoreceptors appear to be mainly affected, evoking predominant sensations of unpleasant dryness.
Collapse
|
24
|
Retracing the evolutionary history of Nothofagus in its geo-climatic context: new developments in the emerging field of phylogeology. GEOBIOLOGY 2014; 12:497-510. [PMID: 25040174 DOI: 10.1111/gbi.12098] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2014] [Accepted: 06/24/2014] [Indexed: 06/03/2023]
Abstract
Phylogeographic studies have made a significant contribution to the interpretation of genetic lineage distribution in response to climate changes, such as during glaciation events of the Neogene. However, the effects of ancient landscapes associated with global sea level rises, tectonic processes, and climatology driving lineage evolution have been largely overlooked. These effects can be tested in widespread lineages of cold-tolerant species that have endured cooling, and thus, phylogeographic patterns may reflect large-scale processes that were not reset by the ice ages. We hereby combine geological evidence from marine sedimentary basins, Andean orogeny, and climatology with molecular dating and statistical phylogeography to infer how geological and climatic processes affected the distribution of lineages in cold-tolerant Nothofagus species during the Cenozoic. A total of 239 populations along the entire range of all species within the genus Nothofagus (N. antarctica, N. betuloides, N. dombeyi, N. nitida, and N. pumilio) were sampled and analyzed by sequencing three non-coding regions of the chloroplast. We found 30 chloroplast DNA haplotypes that were geographically structured. Molecular dating calibrated with fossils revealed that ancestral lineages appeared in Eocene/Oligocene, whereas most divergences took place during the Miocene; in turn, Bayesian skyline plots showed that population expansion occurred in the Early Pleistocene (1.5-1 million years ago). Lineage divergence from all wide-ranging Nothofagus was spatially and temporally concordant with episodic marine transgressions and warmer times in Patagonia during Eocene/Miocene Epochs. Long-lasting stable raised areas preserved haplotype diversity throughout Patagonia, from where cold-tolerant taxa expanded their ranges during pre-Quaternary times. The detailed study of such ancient divergences is novel and allows us to infer the effects of geological processes on distribution patterns of ancient lineages, that is, phylogeology.
Collapse
|
25
|
Corneal Sensory Nerve Activity in an Experimental Model of UV Keratitis. ACTA ACUST UNITED AC 2014; 55:3403-12. [DOI: 10.1167/iovs.13-13774] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
26
|
Corneal sensitivity in diabetic patients subjected to retinal laser photocoagulation. Invest Ophthalmol Vis Sci 2011; 52:6043-9. [PMID: 21447686 DOI: 10.1167/iovs.10-7054] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To determine the changes in corneal sensitivity to different stimulus modalities in diabetes mellitus (DM)1 and DM2 patients with retinopathy, and to explore whether argon laser photocoagulation exacerbates sensitivity loss in diabetic patients. METHODS Corneal sensitivity to different modalities of stimulus was determined in one randomized eye in 52 patients with DM1 (n = 35) or DM2 (n = 17), and in 27 healthy subjects. Medical history was obtained from all the patients, including age, sex, time from DM diagnosis, type of diabetes, time from onset of retinopathy, type of diabetic retinopathy, and type of argon laser treatment. Corneal sensitivity was determined using a gas esthesiometer. Mechanical, chemical, and thermal (heat and cold) stimuli were applied on the central cornea. RESULTS Sensitivity thresholds to selective mechanical, chemical, and cold stimulation were significantly higher in DM patients compared to controls. Sensitivity threshold to mechanical and chemical stimuli was higher in DM2 than in DM1 patients. In DM1 patients, mechanical threshold increased with time after DM diagnosis. No correlation was found between sensitivity thresholds to chemical or thermal stimulation and the age of the patient, type of retinopathy, or time from its diagnosis. Laser treatment generated a further impairment of corneal sensitivity. CONCLUSIONS Corneal sensitivity to mechanical, chemical, and thermal stimulation is decreased in DM patients, suggesting that diabetes affects homogeneously the different types of sensory neurons innervating the cornea. Corneal sensitivity appears to be more disturbed in DM2 than in DM1. Laser treatment of DM patients generates a further impairment in corneal sensitivity, probably as the result of physical damage to ciliary nerves.
Collapse
|
27
|
Ocular surface wetness is regulated by TRPM8-dependent cold thermoreceptors of the cornea. Nat Med 2010; 16:1396-9. [DOI: 10.1038/nm.2264] [Citation(s) in RCA: 222] [Impact Index Per Article: 15.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2010] [Accepted: 10/19/2010] [Indexed: 01/03/2023]
|
28
|
Hair analysis versus conventional methods of drug testing in substance abusers seeking organ transplantation. Am J Transplant 2010; 10:1305-11. [PMID: 20353476 DOI: 10.1111/j.1600-6143.2010.03090.x] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
As substance abusers need to demonstrate abstinence prior to transplant, valid/reliable drug tests are needed. Patients may deny use, fearing surgery will be delayed. Breath, blood and urine tests have brief detection windows that allow patients to evade detection. Routine laboratory tests do not include all substances of abuse. Hair analysis overcomes these barriers, increasing the likelihood that active users will be identified. This study compared results for alcohol, opioids and cocaine based on 445 self-report, breath, urine and hair samples from 42 patients who had been denied a transplant due to recent substance abuse. Compared to hair toxicology, sensitivity for conventional drug tests was moderate for cocaine and opioids, but poor for alcohol. Of positive hair tests, only half were corroborated through other tests. In contrast, specificity was high across tests and substances, with positive findings from conventional tests confirmed through hair toxicology. Based on a 90-day detection window for hair analysis, two negative tests suggest 6 months of continuous abstinence. Hair testing should be considered as an alternative approach for monitoring substance use in the transplant population, either as a routine procedure or when the veracity of findings from conventional tests is in doubt.
Collapse
|
29
|
Selective changes in human corneal sensation associated with herpes simplex virus keratitis. Invest Ophthalmol Vis Sci 2010; 51:4516-22. [PMID: 20375335 DOI: 10.1167/iovs.10-5225] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To determine corneal sensitivity to selective mechanical, chemical, and thermal (heat and cold) stimulation in patients with a history of herpes simplex virus (HSV) keratitis. METHODS Corneal sensitivity to different modalities of stimulus was determined in both eyes of 16 patients with unilateral HSV keratitis diagnosed 1 to 12 months before the study. On slit lamp examination, 13 HSV-affected eyes showed corneal scarring or opacities, and three had no signs of previous keratitis. Corneal sensitivity was determined with the Belmonte gas esthesiometer. Mechanical, chemical, heat, and cold stimuli were applied on the central cornea. Eyes from 10 healthy subjects served as controls. RESULTS In all control and contralateral eyes, selective mechanical, chemical, heat, and cold stimulation evoked sensations of subjective intensity proportional to the magnitude of the applied stimulus. In one HSV patient, the affected cornea was unresponsive to all types of stimuli, four lost only corneal sensitivity to mechanical stimulation, and three lost only sensitivity to heat. Mechanical (P<0.005) and heat (P<0.05) thresholds were raised in HSV eyes, whereas thresholds for CO2 were not modified. Also, HSV subjects identified poorly the intensity of mechanical, chemical, and heat stimuli, whereas sensitivity to cold stimulation was unaffected. CONCLUSIONS In eyes that had had HSV keratitis, corneal sensitivity to mechanical forces and heat was significantly impaired, suggesting that axonal damage and/or altered expression of membrane ion channels involved in transduction and membrane excitability affects primarily the mechano- and polymodal nociceptor terminals. Corneal cold-sensitive terminals remain largely unaffected.
Collapse
|
30
|
Regeneration of functional nerves within full thickness collagen-phosphorylcholine corneal substitute implants in guinea pigs. Biomaterials 2009; 31:2770-8. [PMID: 20042235 DOI: 10.1016/j.biomaterials.2009.12.031] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2009] [Accepted: 12/11/2009] [Indexed: 12/17/2022]
Abstract
Our objective was to evaluate promotion of tissue and nerve regeneration by extracellular matrix (ECM) mimics, using corneal implantation as a model system. Porcine type I collagen and 2-methacryloyloxyethyl phosphorylcholine (MPC) were crosslinked using 1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS) and moulded into appropriate corneal dimensions to serve as substitutes for natural corneal ECM. These were implanted as full thickness grafts by penetrating keratoplasty into the corneas of guinea pigs after removal of the host tissue, and tracked over eight months, by clinical examination, slit-lamp biomicroscopy, and esthesiometry. Histopathology and ex vivo nerve terminal impulse recordings were performed at three months and at eight months. The implants promoted regeneration of corneal cells, nerves and the tear film, while retaining optical clarity. After three months, electrophysiological recordings showed evidence of mechano-nociceptors, and polymodal units inside the implants, while cold-sensitive units were present only on the peripheral host cornea. Following eight months, the incidence of nerve activity and the frequency of spontaneous firing were higher than in control eyes as reported for regenerating fibers. Active cold nerve terminals also innervated the implant area. We show that ECM mimetic materials can promote regeneration of corneal cells and functional nerves. The simplicity in fabrication and demonstrated functionality shows potential for ECM substitutes in future clinical applications.
Collapse
|
31
|
|
32
|
Abstract
PURPOSE To evaluate the changes in spontaneous and stimulus-evoked nerve impulse activity of corneal polymodal and mechanonociceptor sensory fibers of the cornea after photorefractive keratectomy (PRK). METHODS A central corneal ablation 6 mm in diameter and 70 microm in depth was performed with an excimer laser in both eyes of three anesthetized cats, after removal of the corneal epithelium. Single nerve fiber activity was recorded in these animals 12 to 48 hours after surgery. Activity in corneal nerve fibers with receptive fields (RFs) within and/or close to the wound, as well as with RFs far from the lesioned area, was studied. Incidence and frequency of spontaneous discharges and nerve impulse firing responses to mechanical (Cochet-Bonet esthesiometer) and chemical (CO(2) gas pulses) stimuli were studied. RESULTS The incidence of nociceptor fibers exhibiting ongoing activity (15/35 vs. 1/9) and the frequency of their spontaneous firing (0.25 +/- 0.09 impulses [imp]/s versus 0.08 +/- 0.08 imp/s) was higher in fibers with RFs within and/or bordering the wounded area than in those with RFs far away from the wound. Mechanical responsiveness of fibers with RFs within or nearby the ablated area was often reduced. In these fibers, CO(2) pulses evoked a lower-frequency impulse discharge (0.9 +/- 0.2 imp/s inside, 2.3 +/- 0.7 imp/s outside the wound). CO(2)-evoked discharges recorded from fibers innervating the intact wound border were similar to those recorded in corneal fibers of intact cats. CONCLUSIONS The spontaneous impulse activity and the abnormal responsiveness shown by a part of the corneal nerve fibers innervating the injured cornea are presumably the neurophysiological substrate of the pain sensations experienced by human patients hours after PRK surgery.
Collapse
|
33
|
Abstract
Because vision plays a critical role in obtaining information from the external world, evolutionary development has provided the structures that sustain this function with special protection against injury. Thus, the cornea possesses the richest sensory innervation of the body to detect noxious stimuli. The trigeminal sensory neurons that innervate the eye vary in their chemical composition and electrophysiological properties, and can be classified according to the stimuli that activate them preferentially: mechanical forces, temperature, or irritant chemicals. Different classes of noxious stimuli (mechanical injuries, heat, extreme cold) activate to a different degree the various populations of sensory fibers of the ocular surface and evoke unpleasant sensations of distinct quality. When injured either accidentally or following ocular surgery, sensory nerve fibers of the ocular surface may form neuromas that develop abnormal activity and become the source of unpleasant sensations, such as pain, dryness, grittiness, etc. In parallel, their response to natural stimuli is diminished. The possibility of hypesthesia and dysaesthesias must be considered in the assessment of the risks of therapeutic procedures that involve damage to ocular sensory nerves.
Collapse
|
34
|
Relation between corneal innervation with confocal microscopy and corneal sensitivity with noncontact esthesiometry in patients with dry eye. Invest Ophthalmol Vis Sci 2007; 48:173-81. [PMID: 17197530 DOI: 10.1167/iovs.06-0127] [Citation(s) in RCA: 233] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE An alteration in corneal innervation has been described in dry eye associated with diabetes mellitus, contact lens use, and LASIK. The purpose of this study was to evaluate whether dry eye not related to Sjögren's syndrome (NSDE) and dry eye related to primary Sjögren's syndrome (PSDE) are associated with an alteration of the corneal nerves and sensation. METHODS Twenty-one patients with dry eye (10 NSDE and 11 PSDE) and 20 healthy volunteers were studied. Healthy volunteers were divided into two groups: one younger than 60 years (N<60) and the other 60 years of age or older (N> or =60). The study of the epithelium, stroma, and subbasal corneal nerves was performed with a confocal microscope. Mechanical, chemical, and thermal sensation was evaluated using the Belmonte noncontact esthesiometer. RESULTS A statistically significant decrease in the number and density of subbasal nerves (P < 0.0001) and the density of superficial epithelial cells (P < 0.0001) was observed in dry eyes. The number and density of subbasal nerves was higher in the N<60 group. A significant decrease was found with respect to mechanical, chemical, and thermal sensitivity (P < 0.0001). Sensibility was better in the healthy eyes. A strong correlation was found between the density of superficial epithelial cells and the nerves and between the number and density of subbasal nerves and sensation (P < 0.001). CONCLUSIONS The use of confocal microscopy and noncontact esthesiometry allow the detection of the presence of corneal neuropathy in patients with dry eye.
Collapse
|
35
|
Comparative effects of the nonsteroidal anti-inflammatory drug nepafenac on corneal sensory nerve fibers responding to chemical irritation. Invest Ophthalmol Vis Sci 2007; 48:182-8. [PMID: 17197531 DOI: 10.1167/iovs.06-0710] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To compare the corneal analgesic efficacy of the nonsteroidal anti-inflammatory drugs (NSAIDs) nepafenac, diclofenac, and ketorolac, and to evaluate the possibility that their inhibitory effects on corneal polymodal nociceptor fiber activity are partly mediated by a decrease in sodium currents. METHODS Corneal sensory afferent units were recorded in the anesthetized cat. The response of thin myelinated polymodal nociceptor fibers to mechanical and acidic stimulation (98.5% CO(2)) was recorded before and at various times after topical application of the vehicle or of nepafenac 0.1% (Nevanac; Alcon Laboratories, Ltd., Fort Worth, TX), diclofenac 0.1% (Voltaren; Novartis, Basel, Switzerland), and ketorolac 0.4% (Acular LS; Allergan, Irvine, CA). Voltage-clamp recordings were performed in cultured trigeminal ganglion neurons. RESULTS Nepafenac, diclofenac, and ketorolac reduced the mean frequency of the impulse response evoked by repeated CO(2) stimuli in polymodal nociceptor fibers. The progressive increase in ongoing activity, observed in vehicle-treated eyes after repeated acidic stimulation was also prevented. Nepafenac exhibited a more rapid and a slightly more pronounced effect on spontaneous and CO(2)-evoked activity than did diclofenac and ketorolac and did not affect the responsiveness of corneal mechanonociceptor or cold receptor fibers. In cultured mice trigeminal ganglion neurons, diclofenac significantly suppressed sodium currents, whereas nepafenac or its metabolite, amfenac, exhibited only minimal inhibitory effects. CONCLUSIONS The inhibition of polymodal nociceptor activity by nepafenac, a weak inhibitor of cyclooxygenase, is most likely due to its greater lipophilicity compared with diclofenac and ketorolac, leading to a rapid saturation of the corneal epithelium where nociceptor terminals are located. In contrast to diclofenac, nepafenac does not exhibit local anesthetic effects.
Collapse
|
36
|
Abstract
PURPOSE To analyze the levels of the diadenosine polyphosphates Ap4A and Ap5A in tears, in a set of control subjects and in groups of symptomatic and nonsymptomatic persons with dry eye. METHODS Ninety-seven subjects participated in the study. The subjects were divided into five experimental groups: control subjects; symptomatic patients with normal tear secretion; symptomatic patients with low tear secretion; forced blink; and corneal mechanical stimulation provided by a gas esthesiometer. The Schirmer I test was used to measure and collect tear secretions from each subject. All samples were processed by high pressure liquid chromatography (HPLC) and their Ap4A and Ap5A levels determined. RESULTS The levels of Ap4A and Ap5A in tears were greater in all symptomatic patients than in control subjects, especially in symptomatic subjects with low tear secretion. Within the symptomatic subjects with normal tear secretion, significant differences in concentrations of Ap4A and Ap5A were found between men and women. In the forced blink experiments, concentrations of the Ap4A and Ap5A rose with increasing blink frequency. When the cornea was mechanically stimulated, the levels of Ap4A and Ap5A rose significantly during both moderate and high-flow rate tests. CONCLUSIONS The increased levels of Ap4A and Ap5A in tears of patients with dry eye allow these dinucleotides to be used as objective biomarkers in dry eye conditions.
Collapse
|
37
|
Influence of age, gender and iris color on mechanical and chemical sensitivity of the cornea and conjunctiva. Exp Eye Res 2006; 83:932-8. [PMID: 16784741 DOI: 10.1016/j.exer.2006.04.018] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2006] [Revised: 04/13/2006] [Accepted: 04/26/2006] [Indexed: 11/25/2022]
Abstract
The purpose of this study was to establish the influence of age, gender and iris color on the mechanical and chemical sensitivity of the cornea and the conjunctiva. In 57 healthy subjects (27 males, 30 females; ages between 23 and 71 years), sensory thresholds to mechanical and chemical stimulation were measured in the central cornea and the temporal conjunctiva using a Belmonte's gas esthesiometer. Mechanical stimulation consisted of warmed air pulses of 3s duration at different flow rates (40-200 ml/min). For chemical (acidic) stimulation, 3-s warmed gas pulses containing 10% to 80% CO(2) in air were applied, at a flow below mechanical threshold flow. Corneal and conjunctival thresholds to mechanical and chemical stimuli increased with age. Premenopausal women were more sensitive to corneal stimulation than men of similar ages but overall differences in mechanical and chemical threshold between men and women were not significant. Individuals with blue eyes had significantly lower corneal chemical thresholds than those with brown or green eyes. Multiple linear regression analysis evidenced that corneal mechanical threshold depends on age and iris color according to the equation 58.2 ml/min+1.3.(Age-23 years)-9.7 if blue eyes. For chemical threshold, the equation was 28.6%CO(2)+05.(Age-23 years)-12.5 if blue eyes. In the case of the conjunctiva, only age determined mechanical and chemical thresholds according to the equations: 78.2 ml/min+1.4.(Age-23 years) and 41.6%CO(2)+0.8.(Age-23 years), respectively. Therefore, normal values of mechanical and chemical thresholds of the cornea and conjunctiva measured with the Belmonte gas esthesiometer can be predicted according to age and iris color. Variations of sensitivity with age, iris color and gender may reflect differences in innervation density and neural responsiveness associated with the hormonal status.
Collapse
|
38
|
Barium ions inhibit the dynamic response of guinea-pig corneal cold receptors to heating but not to cooling. J Physiol 2006; 575:573-81. [PMID: 16793903 PMCID: PMC1819461 DOI: 10.1113/jphysiol.2006.110130] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2006] [Accepted: 06/19/2006] [Indexed: 12/29/2022] Open
Abstract
An in vitro preparation of the guinea-pig cornea was used to study the effects of the K+ channel blockers 4-aminopyridine (4-AP), tetraethylammonium (TEA) and Ba2+ on nerve terminal impulses (NTIs) recorded extracellularly from cold sensory receptors. These receptors have an ongoing discharge of NTIs that is increased by cooling and decreased by heating. The K+ channel blocker 4-AP reduced the negative amplitude of the diphasic (positive-negative) NTIs, whereas TEA and Ba2+ prolonged the duration of the negative component. As the shape of the NTI is determined by the first derivative (dV/dt) of the membrane voltage change, these changes in the negative component are consistent with the blockade of K+ channels that contribute to action potential repolarization. Only TEA changed the basal activity of the receptors, increasing the likelihood of burst discharges. Ba2+ selectively reduced the response of the receptors to heating, whereas neither 4-AP nor TEA modified the response to heating or to cooling. The findings indicate that K+ channels blocked by 4-AP, TEA and Ba2+ contribute to action potential repolarization in corneal cold receptors, and that ionic mechanisms that underlie the reduction in NTI frequency in response to heating differ from those that increase activity in response to cooling.
Collapse
|
39
|
Abstract
PURPOSE To explore changes in corneal sensitivity that develop in patients with dry eye and the relationship between sensibility and severity of the dry eye disease. METHODS Experiments were performed in 44 patients with dry eye and 42 healthy individuals. Corneal sensitivity was measured with the Belmonte noncontact gas esthesiometer. Mechanical (air jets at flow rates from 0 to 200 mL/min, reaching the corneal surface at 34 degrees C), thermal (cold or warm air at subthreshold flow rates changing corneal basal temperature +/-1 degrees C), and chemical stimuli (air containing 0% to 50% CO2 at subthreshold flow rate and temperature at the cornea of 34 degrees C) were applied to the center of the cornea to determine the sensitivity threshold for each stimulus modality. The clinical state of the ocular surface was also explored, measuring the fluorescein tear break-up time, the degree of corneal staining with fluorescein and Lissamine green, and tear production with the Schirmer test. RESULTS Both in control subjects and patients with dry eye, the corneal thresholds for mechanical, chemical, and thermal stimulation increased with age. Moreover, the thresholds for the three modalities of stimuli were significantly higher in patients with dry eye than in control subjects. In both groups, individual mechanical, chemical, and thermal thresholds correlated significantly. Also, high thresholds in patients with dry eye correlated with the intensity of fluorescein and Lissamine green corneal staining but not with the results of the Schirmer test. CONCLUSIONS Patients with dry eye exhibit corneal hypoesthesia after mechanical, thermal, and chemical stimulation that appears to be related to damage to the corneal sensory innervation.
Collapse
|
40
|
Changes in mechanical, chemical, and thermal sensitivity of the cornea after topical application of nonsteroidal anti-inflammatory drugs. Invest Ophthalmol Vis Sci 2005; 46:282-6. [PMID: 15623785 DOI: 10.1167/iovs.04-0884] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE In addition to their well-known anti-inflammatory actions, some of the nonsteroidal anti-inflammatory drugs (NSAIDs) appear to have an analgesic effect. In human subjects, the changes in threshold and intensity of sensations evoked by mechanical, chemical, and thermal stimulation of the cornea induced by topical administration of two commercial NSAIDs, diclofenac sodium (Voltaren; Novartis, Basel, Switzerland) and flurbiprofen (Ocuflur; Allergan, Irvine, CA), were studied. METHODS Corneal sensitivity was measured in 10 young, healthy subjects with a gas esthesiometer. Chemical (10%-70% CO2 in air), mechanical (0-264 mL/min), and thermal (corneal temperature changes between -4.5 degrees C and +3 degrees C around the normal value) stimuli were applied to the center of the cornea. The intensity and perceived magnitude of the psychophysical attributes of the evoked sensation were scored at the end of the pulse in a 10-cm, continuous visual analog scale (VAS). The threshold was expressed as the stimulus intensity that evoked a VAS score >0.5. Sensitivity was measured in both eyes of each subject on two separate days, one without treatment and the other 30 minutes after topical application of 0.03% flurbiprofen (seven subjects) or 0.1% diclofenac sodium (six subjects). RESULTS Diclofenac attenuated significantly all the sensation parameters evoked by high-intensity mechanical, chemical, and thermal stimuli. Flurbiprofen produced a slight reduction of the sensations evoked by mechanical and chemical stimulation that became significant only for the irritation caused by chemical stimuli of maximum intensity (70% CO2). None of the drugs modified significantly the detection threshold of the different stimuli. CONCLUSIONS Flurbiprofen had a very limited effect on sensations evoked by corneal stimulation, whereas diclofenac reduced the intensity of sensations evoked by stimuli of different modality, suggesting a mild local anesthetic effect of this drug on all types of corneal sensory fibers. Such anesthetic action could explain the analgesic effect that has been reported after topical application of diclofenac in inflamed human eyes.
Collapse
|
41
|
Tear secretion induced by selective stimulation of corneal and conjunctival sensory nerve fibers. Invest Ophthalmol Vis Sci 2004; 45:2333-6. [PMID: 15223813 DOI: 10.1167/iovs.03-1366] [Citation(s) in RCA: 68] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To measure the increase in tear secretion evoked by selective stimulation of the different populations of sensory receptors of the cornea and conjunctiva by using moderate and intense mechanical, chemical, and cold stimuli. METHODS Six healthy subjects participated in the study. Tear secretion was measured in both eyes by the Schirmer's test conducted under control conditions and after stimulation of the center of the cornea and the temporal conjunctiva with a gas esthesiometer. Mechanical stimulation consisted in three pulses of 3 seconds' duration of warmed air (at 34 degrees C on the eye surface) applied at moderate (170 mL/min) and high (260 mL/min) flow rates. Cold thermal stimulation was made with cooled air that produced a corneal temperature drop of -1 degrees C or -4.5 degrees C. Chemical (acidic) stimulation was performed with a jet of gas containing a mixture of 80% CO(2) in air. RESULTS The basal volume of tear secretion increased significantly (P < 0.05, paired t-test) after stimulation of the cornea with high-flow mechanical stimuli (260 mL/min), intense cooling pulses (-4.5 degrees C), and chemical stimulation (80% CO(2)). The same stimuli were ineffective when applied to the conjunctiva. Moderate mechanical (170 mL/min) and cold (-1 degrees C) stimulation of the cornea or the conjunctiva did not change significantly the volume of tear secretion. CONCLUSIONS Reflex tear secretion caused by corneal stimulation seems to be chiefly due to activation of corneal polymodal nociceptors, whereas selective excitation of corneal mechanonociceptors or cold receptors appears to be less effective in evoking an augmented lacrimal secretion. Conjunctival receptors stimulated at equivalent levels do not evoke an increased tear secretion.
Collapse
|
42
|
Recovery of Corneal Sensitivity to Mechanical and Chemical Stimulation After Laser in situ Keratomileusis. J Refract Surg 2004; 20:229-35. [PMID: 15188899 DOI: 10.3928/1081-597x-20040501-06] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the time course of changes in corneal sensitivity to mechanical and chemical stimuli produced by laser in situ keratomileusis (LASIK) in humans. METHODS We performed a cross-sectional study of 17 LASIK-operated eyes (VisX S2, equipped with version 2.50-3.10 software) and 15 control eyes of 17 individuals to evaluate regeneration of corneal sensitivity after LASIK. Gas pulses of variable flow and compositions were applied to the cornea by a non-contact gas esthesiometer. Mechanical stimuli consisted of air puffs at flows from 0 to 200 ml/min. Chemical stimulation was made with gas pulses containing 0% to 80% CO2 in air at subthreshold flow. Mechanical and chemical thresholds and intensity-response curves for the evoked sensations were determined prior to surgery, and 7 to 9 days, 3 to 5 months, and 1.5 to 2.5 years after surgery. RESULTS Corneal sensitivity to mechanical stimulation was enhanced 7 to 9 days after surgery but subsequently dropped markedly and remained significantly below control levels 3 to 5 months after LASIK. Sensitivity to both mechanical and chemical types of stimuli was close to normal 2 years postoperatively. CONCLUSIONS Corneal sensitivity decreased immediately after LASIK but mechanical sensitivity showed a transient hyperesthesia 7 to 9 days afterward. Subsequently, a long-lasting and deep hypoesthesia to mechanical and chemical stimuli was observed. Gas esthesiometry revealed that disturbances of corneal sensation still exist at times when coarse mechanical sensitivity appeared to be normal.
Collapse
|
43
|
Abstract
A renewed interest in the characteristics and neural basis of corneal and conjunctival sensations is developing in recent years due to the high incidence of discomfort and altered sensitivity of the cornea following refractive surgery, use of contact lenses and dry eyes. Corneal nerves are functionally heterogeneous: about 20% respond exclusively to noxious mechanical forces (mechano-nociceptors); 70% are additionally excited by extreme temperatures, exogenous irritant chemicals and endogenous inflammatory mediators (polymodal nociceptors), and 10% are cold-sensitive and increase their discharge with moderate cooling of the cornea (cold receptors). Each of these types of sensory fibres contributes distinctly to corneal sensations. Mechano-nociceptors mediate, sharp acute pain produced by touching of the cornea. Polymodal nociceptors elicit the sustained irritation and pain that accompany corneal wounding; cold receptors evoke cooling sensations. Depending on the relative activation by the stimulus of each subpopulation of corneal sensory fibres, different subqualities of irritation and pain sensations are evoked. Corneal sensations can be explored experimentally in humans with a gas esthesiometer that applies controlled mechanical, chemical and thermal stimuli to the corneal surface. When the cornea is wounded, corneal nerves are excited and eventually severed in a variable degree and local inflammation is produced. Activated corneal nerves release neuropeptides (SP, CGRP) that contribute to the inflammatory reaction (neurogenic inflammation). They also become sensitized by local inflammatory mediators, such as prostaglandins or bradykinin and thus exhibit spontaneous activity, lowered threshold and enhanced responses to new stimuli. This leads to spontaneous pain and hyperalgesia. Nerves destroyed by injury soon start to regenerate and form microneuromas that exhibit abnormal responsiveness and spontaneous discharges, due to an altered expression of ion channel proteins in the soma and in regenerating nerve terminals. Presumably, this altered excitability is the origin of the lowered sensitivity and the spontaneous pain, dry eye sensations and other disaesthesias reported in patients following refractive surgery.
Collapse
|
44
|
Tobacco specific nitrosamines and potential reduced exposure products for smokers: a preliminary evaluation of Advance. Tob Control 2003; 12:317-21. [PMID: 12958395 PMCID: PMC1747748 DOI: 10.1136/tc.12.3.317] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
OBJECTIVE To develop a method for evaluating the carcinogen delivery of potential reduced exposure products (PREPs) like Advance, a PREP marketed to reduce smokers' exposure to one tobacco specific nitrosamine (TSN), NNK, a potent lung carcinogen. DESIGN, SETTING, AND PARTICIPANTS Latin square ordered, three condition, outpatient, crossover design with 12 smokers of light or ultra-light cigarettes (15 or more cigarettes/day). In each five day condition, participants either smoked own brand, Advance, or no cigarettes. Also, on the first and last day of each condition, participants smoked one cigarette in the laboratory. MAIN OUTCOME MEASURES Subject rated measures of tobacco/nicotine withdrawal, expired air carbon monoxide, urine concentrations of cotinine and NNAL (one TSN biomarker), puff volume, duration, number, and interpuff interval. RESULTS Relative to own brand, Advance produced similar withdrawal suppression, slightly lower carbon monoxide, equivalent cotinine, and 51% lower NNAL concentrations. The lowest cotinine and NNAL concentrations were observed in the no cigarette condition. Participants took fewer puffs when smoking Advance. CONCLUSIONS Past experience with PREPs that failed to reduce smoking's harm demonstrates the need for clinical methods in PREP evaluation. This study shows how assessing PREP induced changes in withdrawal and exposure to carbon monoxide, nicotine, and carcinogens may help predict PREP harm reduction potential. Adequate withdrawal suppression, slightly lower concentrations of carbon monoxide, and reduction of one TSN biomarker were observed for Advance. In the future, clinical methods like those described here may be valuable for evaluating PREPs before they are marketed publicly.
Collapse
|
45
|
Activation of scleral cold thermoreceptors by temperature and blood flow changes. Invest Ophthalmol Vis Sci 2003; 44:697-705. [PMID: 12556401 DOI: 10.1167/iovs.02-0226] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To study the response of scleral cold receptors located in areas of the eye unexposed to temperature and blood flow changes. METHODS In anesthetized cats, the neural activity was recorded from single, cold-sensory fibers of the ciliary nerves innervating the sclera and limbus. Controlled temperature changes of the receptive field were performed with a contact thermode. Ocular blood flow reductions were obtained by occluding the ipsilateral common carotid artery for 30 to 60 seconds with a compressor placed around the artery. Local blood flow was measured with a laser Doppler flowmeter. Temperature was measured with a microprobe introduced in the subscleral space. Ocular sympathetic stimulation was performed with a pair of silver electrodes placed on the preganglionic cervical sympathetic trunk. To induce local hypoxia, N(2) was applied on the scleral surface with a specially designed chamber. For systemic hypoxia the breathing air was replaced with a gas mixture containing 10% O(2) in N(2). RESULTS Sensory nerve fibers identified as cold receptors exhibited ongoing nerve activity in bursts at 35 degrees C and responded to cooling pulses applied to their receptive fields with an increase in the impulse discharge that reached a peak and decayed gradually to a lower level. When temperature was reduced from 35 degrees C to 34 degrees C, frequency increased monotonically with decreasing temperature of the sclera. Between 35 degrees C and 30 degrees C, peak and mean frequencies were roughly proportional to temperature of the sclera. The characteristics of burst discharges also depended on scleral temperature. Electrical stimulation of the cervical sympathetic trunk induced a decrease in blood flow and temperature and evoked an increase in the firing frequency of cold-sensory fibers that was proportional to the frequency of stimulating pulses. Carotid occlusion also elicited an increase of the discharge of cold thermoreceptor fibers that occurred in parallel with a decrease in blood flow and temperature in the receptive field area. Local or systemic hypoxia did not modify appreciably the spontaneous firing frequency of scleral cold-sensory fibers. CONCLUSIONS Scleral and episcleral cold-sensory fibers encoded as a change in their impulse frequency and firing pattern temperature reductions of less than 1 degrees C in scleral tissues. Activation of scleral and episcleral cold-sensory fibers by sympathetic vasoconstriction and acute arterial pressure reductions appear to be secondary to the temperature decrease that accompanies the reduction in ocular blood flow caused by these maneuvers. Scleral thermosensory fibers are located in ocular territories not directly exposed to external temperature changes. Thus, the sensory information on local blood flow variations provided by these receptors may be involved in a reflex regulation of choroidal blood flow that functions to maintain a constant temperature and blood supply to the retina.
Collapse
|
46
|
Abstract
In this paper, we consider the effect of attachment disruptions on severe adjustment problems in school-age boys. Three groups of 9-11-year-old boys were sampled based on their degree of risk for adjustment difficulties: (1) boys in regular classrooms, (2) boys in regular classrooms who are at risk due to poverty, and (3) boys who have been placed in special education classrooms as a result of serious emotional disturbance (SED). Attachment disruptions were categorized according to the severity of major separations from the biological mother. SED children experienced significantly more severe disruptions of their relationships with their biological mothers and fathers than either the high-risk or comparison boys. Teachers' ratings indicated that both the high-risk and SED boys experienced more externalizing symptoms than comparison boys in regular classrooms. However, SED children were most clearly discriminated from their high-risk and comparison counterparts by higher levels of dissociative symptoms. Regression analyses indicated that children who had experienced maternal attachment disruptions were more likely to show dissociative symptomatology in the classroom setting and were more likely to develop dependent relationships with their teachers after risk group status, child age and family structure were controlled. Implications of these findings for the treatment of SED children are discussed.
Collapse
|
47
|
Sensations evoked by selective mechanical, chemical, and thermal stimulation of the conjunctiva and cornea. Invest Ophthalmol Vis Sci 2001; 42:2063-7. [PMID: 11481273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/20/2023] Open
Abstract
PURPOSE To study the sensations evoked by selective mechanical, chemical, and thermal stimulation of the conjunctiva and compare them with those elicited by similar stimulation of the cornea. METHODS Six young subjects participated in the study. Using a gas esthesiometer, selective mechanical (air puffs at flows from 0 to 264 ml/min), chemical (0--80% CO(2) in air), and thermal (air at temperatures from -10 degrees C to +80 degrees C) stimulation was performed on the center of the cornea and on the temporal conjunctiva. The intensity, degree of irritation, stinging and burning pain components, and thermal characteristics of the evoked sensation were evaluated after each stimulus in separate, 10-cm continuous visual analogue scales (VASs). The ability of the subjects to identify the quality of the stimulus applied to the cornea and the conjunctiva was also studied. RESULTS The subjective intensity and thermal components (cooling or warming) of the sensation reported after mechanical, chemical, and heat stimulation were similar in the conjunctiva and cornea, although lower VAS scores were always reported in the conjunctiva for the irritation and the stinging and burning pain components. In the cornea, stimulation with low temperatures was perceived as a cooling sensation with an irritative component. In the conjunctiva, cooling was perceived as a purely cold sensation. Subjects showed similar discrimination capability in the cornea and the conjunctiva for the various types of stimuli. CONCLUSIONS Sensations evoked in the cornea by selective mechanical, chemical, and heat and cold stimulation always presented an irritation component. In the conjunctiva, stimuli of the same intensity are always perceived as less irritating than in the cornea. Cold and other non-noxious subqualities of sensation can be evoked in the conjunctiva.
Collapse
|
48
|
Sensory experiences in humans and single-unit activity in cats evoked by polymodal stimulation of the cornea. J Physiol 2001; 534:511-25. [PMID: 11454968 PMCID: PMC2278705 DOI: 10.1111/j.1469-7793.2001.t01-1-00511.x] [Citation(s) in RCA: 103] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2001] [Accepted: 03/13/2001] [Indexed: 11/26/2022] Open
Abstract
1. The cornea of human subjects and of anaesthetised cats was stimulated with a jet of air of controlled flow, temperature and CO(2) concentration delivered by a gas aesthesiometer. 2. In humans, the intensity and magnitude of various components of the sensory experience (intensity of the sensation, degree of irritation, magnitude of burning and stinging pain, magnitude of the cold and warm components of the sensation) were measured using separate visual analog scales. In anaesthetised cats, the impulse response to the same stimuli was recorded from single mechanosensory, polymodal and cold-sensitive corneal fibres in the ciliary nerves. 3. Intensity-response curves for mechanical stimulation showed that all parameters of the sensation experienced by humans increased with the intensity of the stimulus. Mechanical stimuli recruited mainly phasic mechanosensory and polymodal afferents in the cat. 4. Acidic stimulation with gas mixtures of increasing CO(2) concentration evoked irritation, burning and to a lesser extent stinging pain of a magnitude roughly proportional to the intensity of the stimulus in humans. CO(2) primarily recruited polymodal afferents and weakly excited cold-sensitive fibres in the cat's cornea. 5. Heat stimuli evoked in humans a sensation profile similar to CO(2) but accompanied by a warmth component. In the cat's cornea, heat excited only polymodal fibres and silenced cold-sensitive corneal units. 6. Cold stimuli applied to the human cornea elicited a sensation of cooling that became irritant at the lowest temperatures. Corneal cold-sensitive fibres of the cat were activated in a manner proportional to the temperature drop, while polymodal nociceptor fibres were recruited only by the lowest temperatures. Topical menthol (0.2 mM) applied to humans evoked and later eliminated cold sensations produced by cold stimuli while the irritation sensation caused by low temperature stimuli still persisted. 7. Human subjects were able to identify masked mechanical, thermal and chemical stimuli applied to the cornea. 8. Irritation and cold sensations can therefore be evoked separately from the cornea by selective activation of mechanosensory, polymodal and cold corneal sensory afferents. Stimulation with different forms of energy usually leads to combined activation and/or inhibition of the different populations of sensory afferent fibres, evoking blended sensations that include irritation and thermal components in a variable degree.
Collapse
|
49
|
Corneal morphology and sensitivity in lattice dystrophy type II (familial amyloidosis, Finnish type). Invest Ophthalmol Vis Sci 2001; 42:634-41. [PMID: 11222521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/19/2023] Open
Abstract
PURPOSE To describe the corneal abnormalities and to measure different modalities of corneal sensitivity in corneal lattice dystrophy type II (familial amyloidosis, Finnish type, also known as gelsolin-related amyloidosis and originally as Meretoja syndrome). METHODS Twenty eyes of 20 patients were examined by in vivo confocal microscopy and noncontact gas esthesiometry. RESULTS Pleomorphism of, and dense deposits between or posterior to, the basal epithelial cells were frequently observed, as well as a reduction of long nerve fiber bundles in the subbasal nerve plexus. The anterior stroma was altered in most cases, with fibrosis and abnormal extracellular matrix. In 15 corneas, thick anterior and midstromal filaments, corresponding to lattice lines, and in 11 corneas, thin undulated structures were observed. The average mechanical sensitivity threshold of 12 subjects was increased, and in the remaining 8 subjects there was no response, even to the highest intensity of stimuli used. Three patients did not respond to CO(2), 11 to heat, and 2 to cold, but those patients who responded had normal thresholds. Patients with more long nerve fiber bundles per confocal microscopic image had better mechanical and cold sensitivity than patients with fewer nerve fiber bundles. CONCLUSIONS Lattice lines seem to be related to amyloid material and not to corneal nerves. However, the subbasal nerve density appears reduced, which results mainly in a decrease in mechanical and, to a lesser extent, thermal sensitivity. The location of stromal filaments and undulated structures changes with increasing age.
Collapse
|
50
|
Systemically administered interleukin-10 reduces tumor necrosis factor-alpha production and significantly improves functional recovery following traumatic spinal cord injury in rats. J Neurotrauma 1999; 16:851-63. [PMID: 10547095 DOI: 10.1089/neu.1999.16.851] [Citation(s) in RCA: 303] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
In these studies, we examined the neuroprotective effects of the potent antiinflammatory cytokine interleukin-10 (IL-10) following spinal cord injury (SCI). Neuroprotection was assessed by using behavioral and morphological end points. We hypothesized that injury-induced inflammation contributes to the resulting neuropathology and subsequent loss of function. Therefore, by attenuating injury-induced inflammation, we should promote functional recovery. The New York University device was used to induce moderate SCI and study the resulting inflammatory response and functional consequences of inhibiting this response in rats. We determined that SCI induces the expression of tumor necrosis factor-alpha (TNF-alpha) in the spinal cord and by SCI-activated monocytes isolated from the peripheral circulation. IL-10 (5.0 microg) administered 30 minutes after-injury significantly reduced the expression of TNF-alpha protein in the spinal cord and in vitro by SCI-activated monocytes. Next, we investigated whether IL-10 would improve functional recovery after SCI. Randomized, double-blinded studies demonstrated that a single injection of IL-10 significantly improves hind limb motor function 2 months after injury, as determined by the Basso, Beattie and Bresnahan (BBB) open-field behavioral test. IL-10-treated animals had a mean BBB score of 18.0+/-0.5 (SEM, n = 9) compared with a score of 12.9+/-0.6 (SEM, n = 9) for the saline-treated controls. Morphological analysis demonstrated that IL-10 reduces lesion volume by approximately 49% 2 months after injury. These data suggest that acute administration of IL-10 reduces TNF-alpha synthesis in the spinal cord and by activated macrophages, is neuroprotective, and promotes functional recovery following SCI.
Collapse
|