1
|
Towards a comprehensive biomechanical assessment of the elderly combining in vivo data and in silico methods. Front Bioeng Biotechnol 2024; 12:1356417. [PMID: 38770274 PMCID: PMC11102974 DOI: 10.3389/fbioe.2024.1356417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 04/18/2024] [Indexed: 05/22/2024] Open
Abstract
The aging process is commonly accompanied by a general or specific loss of muscle mass, force and/or function that inevitably impact on a person's quality of life. To date, various clinical tests and assessments are routinely performed to evaluate the biomechanical status of an individual, to support and inform the clinical management and decision-making process (e.g., to design a tailored rehabilitation program). However, these assessments (e.g., gait analysis or strength measures on a dynamometer) are typically conducted independently from one another or at different time points, providing clinicians with valuable yet fragmented information. We hereby describe a comprehensive protocol that combines both in vivo measurements (maximal voluntary isometric contraction test, superimposed neuromuscular electrical stimulation, electromyography, gait analysis, magnetic resonance imaging, and clinical measures) and in silico methods (musculoskeletal modeling and simulations) to enable the full characterization of an individual from the biomechanical standpoint. The protocol, which requires approximately 4 h and 30 min to be completed in all its parts, was tested on twenty healthy young participants and five elderlies, as a proof of concept. The implemented data processing and elaboration procedures allowing for the extraction of several biomechanical parameters (including muscle volumes and cross-sectional areas, muscle activation and co-contraction levels) are thoroughly described to enable replication. The main parameters extracted are reported as mean and standard deviation across the two populations, to highlight the potential of the proposed approach and show some preliminary findings (which were in agreement with previous literature).
Collapse
|
2
|
Development and validation of a semi-automated and unsupervised method for femur segmentation from CT. Sci Rep 2024; 14:7403. [PMID: 38548805 PMCID: PMC10978861 DOI: 10.1038/s41598-024-57618-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 03/20/2024] [Indexed: 04/01/2024] Open
Abstract
Quantitative computed tomography (QCT)-based in silico models have demonstrated improved accuracy in predicting hip fractures with respect to the current gold standard, the areal bone mineral density. These models require that the femur bone is segmented as a first step. This task can be challenging, and in fact, it is often almost fully manual, which is time-consuming, operator-dependent, and hard to reproduce. This work proposes a semi-automated procedure for femur bone segmentation from CT images. The proposed procedure is based on the bone and joint enhancement filter and graph-cut algorithms. The semi-automated procedure performances were assessed on 10 subjects through comparison with the standard manual segmentation. Metrics based on the femur geometries and the risk of fracture assessed in silico resulting from the two segmentation procedures were considered. The average Hausdorff distance (0.03 ± 0.01 mm) and the difference union ratio (0.06 ± 0.02) metrics computed between the manual and semi-automated segmentations were significantly higher than those computed within the manual segmentations (0.01 ± 0.01 mm and 0.03 ± 0.02). Besides, a blind qualitative evaluation revealed that the semi-automated procedure was significantly superior (p < 0.001) to the manual one in terms of fidelity to the CT. As for the hip fracture risk assessed in silico starting from both segmentations, no significant difference emerged between the two (R2 = 0.99). The proposed semi-automated segmentation procedure overcomes the manual one, shortening the segmentation time and providing a better segmentation. The method could be employed within CT-based in silico methodologies and to segment large volumes of images to train and test fully automated and supervised segmentation methods.
Collapse
|
3
|
Variability of intervertebral joint stiffness between specimens and spine levels. Front Bioeng Biotechnol 2024; 12:1372088. [PMID: 38486868 PMCID: PMC10937554 DOI: 10.3389/fbioe.2024.1372088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Accepted: 02/19/2024] [Indexed: 03/17/2024] Open
Abstract
Introduction: Musculoskeletal multibody models of the spine can be used to investigate the biomechanical behaviour of the spine. In this context, a correct characterisation of the passive mechanical properties of the intervertebral joint is crucial. The intervertebral joint stiffness, in particular, is typically derived from the literature, and the differences between individuals and spine levels are often disregarded. Methods: This study tested if an optimisation method of personalising the intervertebral joint stiffnesses was able to capture expected stiffness variation between specimens and between spine levels and if the variation between spine levels could be accurately captured using a generic scaling ratio. Multibody models of six T12 to sacrum spine specimens were created from computed tomography data. For each specimen, two models were created: one with uniform stiffnesses across spine levels, and one accounting for level dependency. Three loading conditions were simulated. The initial stiffness values were optimised to minimize the kinematic error. Results: There was a range of optimised stiffnesses across the specimens and the models with level dependent stiffnesses were less accurate than the models without. Using an optimised stiffness substantially reduced prediction errors. Discussion: The optimisation captured the expected variation between specimens, and the prediction errors demonstrated the importance of accounting for level dependency. The inaccuracy of the predicted kinematics for the level-dependent models indicated that a generic scaling ratio is not a suitable method to account for the level dependency. The variation in the optimised stiffnesses for the different loading conditions indicates personalised stiffnesses should also be considered load-specific.
Collapse
|
4
|
Chronological Changes in Sagittal Femoral Bowing after Primary Cementless Total Hip Arthroplasty: A Comparative 3D CT Study. J Pers Med 2023; 13:1704. [PMID: 38138931 PMCID: PMC10744357 DOI: 10.3390/jpm13121704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 11/15/2023] [Accepted: 12/07/2023] [Indexed: 12/24/2023] Open
Abstract
Little is known about dynamic changes of femoral anatomy after total hip arthroplasty (THA), in particular about sagittal femoral bowing (SFB). A 3D CT study was designed to evaluate the chronological changes of SFB after cementless femoral stem implantation for primary THA. Ten patients who underwent unilateral primary THA with a cementless femoral stem, with 2 consecutive CT scans (extending from the fourth lumbar vertebra to the tibial plateaus), performed before THA and at least 3 years after THA, were enrolled. The 3D models of femurs were created using image segmentation software. Using the two CT scans, SFB values of the proximal and middle thirds were calculated on the replaced and untreated sides by two different observers. Eight anatomical stems and two conical stems were involved. The post-operative CT was performed at an average follow-up of 6.5 years after THA (range: 3-12.5). The measurements performed by the two observers did not differ in the proximal and middle regions. A significant difference between the pre-operative and post-operative SFB compared to the untreated side was found in the proximal femur segment (p = 0.004). Use of a cementless stem in THA induced chronological changes in SFB of the proximal femur, after a minimum timespan of 3 years.
Collapse
|
5
|
A multiscale orchestrated computational framework to reveal emergent phenomena in neuroblastoma. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 241:107742. [PMID: 37572512 DOI: 10.1016/j.cmpb.2023.107742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 07/19/2023] [Accepted: 07/31/2023] [Indexed: 08/14/2023]
Abstract
Neuroblastoma is a complex and aggressive type of cancer that affects children. Current treatments involve a combination of surgery, chemotherapy, radiotherapy, and stem cell transplantation. However, treatment outcomes vary due to the heterogeneous nature of the disease. Computational models have been used to analyse data, simulate biological processes, and predict disease progression and treatment outcomes. While continuum cancer models capture the overall behaviour of tumours, and agent-based models represent the complex behaviour of individual cells, multiscale models represent interactions at different organisational levels, providing a more comprehensive understanding of the system. In 2018, the PRIMAGE consortium was formed to build a cloud-based decision support system for neuroblastoma, including a multi-scale model for patient-specific simulations of disease progression. In this work we have developed this multi-scale model that includes data such as patient's tumour geometry, cellularity, vascularization, genetics and type of chemotherapy treatment, and integrated it into an online platform that runs the simulations on a high-performance computation cluster using Onedata and Kubernetes technologies. This infrastructure will allow clinicians to optimise treatment regimens and reduce the number of costly and time-consuming clinical trials. This manuscript outlines the challenging framework's model architecture, data workflow, hypothesis, and resources employed in its development.
Collapse
|
6
|
Position paper From the digital twins in healthcare to the Virtual Human Twin: a moon-shot project for digital health research. IEEE J Biomed Health Inform 2023; PP:1-11. [PMID: 37819828 DOI: 10.1109/jbhi.2023.3323688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/13/2023]
Abstract
The idea of a systematic digital representation of the entire known human pathophysiology, which we could call the Virtual Human Twin, has been around for decades. To date, most research groups focused instead on developing highly specialised, highly focused patient-specific models able to predict specific quantities of clinical relevance. While it has facilitated harvesting the low-hanging fruits, this narrow focus is, in the long run, leaving some significant challenges that slow the adoption of digital twins in healthcare. This position paper lays the conceptual foundations for developing the Virtual Human Twin (VHT). The VHT is intended as a distributed and collaborative infrastructure, a collection of technologies and resources (data, models) that enable it, and a collection of Standard Operating Procedures (SOP) that regulate its use. The VHT infrastructure aims to facilitate academic researchers, public organisations, and the biomedical industry in developing and validating new digital twins in healthcare solutions with the possibility of integrating multiple resources if required by the specific context of use. Healthcare professionals and patients can also use the VHT infrastructure for clinical decision support or personalised health forecasting. As the European Commission launched the EDITH coordination and support action to develop a roadmap for the development of the Virtual Human Twin, this position paper is intended as a starting point for the consensus process and a call to arms for all stakeholders.
Collapse
|
7
|
Comparative validation of two patient-specific modelling pipelines for predicting knee joint forces during level walking. J Biomech 2023; 159:111758. [PMID: 37659354 DOI: 10.1016/j.jbiomech.2023.111758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 07/28/2023] [Accepted: 08/07/2023] [Indexed: 09/04/2023]
Abstract
Over the past few years, the use of computer models and simulations tailored to the patient's physiology to assist clinical decision-making has increased enormously.While several pipelines to develop personalized models exist, their adoption on a large scale is still limited due to the required niche computational skillset and the lengthy operations required. Novel toolboxes, such as STAPLE, promise to streamline and expedite the development of image-based skeletal lower limb models. STAPLE-generated models can be rapidly generated, with minimal user input, and present similar joint kinematics and kinetics compared to models developed employing the established INSIGNEO pipeline. Yet, it is unclear how much the observed discrepancies scale up and affect joint contact force predictions. In this study, we compared image-based musculoskeletal models developed (i) with the INSIGNEO pipeline and (ii) with a semi-automated pipeline that combines STAPLE and nmsBuilder, and assessed their accuracy against experimental implant data.Our results showed that both pipelines predicted similar total knee joint contact forces between one another in terms of profiles and average values, characterized by a moderately high level of agreement with the experimental data. Nonetheless, the Student t-test revealed statistically significant differences between both pipelines. Of note, the STAPLE-based pipeline required considerably less time than the INSIGNEO pipeline to generate a musculoskeletal model (i.e., 60 vs 160 min). This is likely to open up opportunities for the use of personalized musculoskeletal models in clinical practice, where time is of the essence.
Collapse
|
8
|
Modeling Human Suboptimal Control: A Review. J Appl Biomech 2023; 39:294-303. [PMID: 37586711 DOI: 10.1123/jab.2023-0015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 07/03/2023] [Accepted: 07/03/2023] [Indexed: 08/18/2023]
Abstract
This review paper provides an overview of the approaches to model neuromuscular control, focusing on methods to identify nonoptimal control strategies typical of populations with neuromuscular disorders or children. Where possible, the authors tightened the description of the methods to the mechanisms behind the underlying biomechanical and physiological rationale. They start by describing the first and most simplified approach, the reductionist approach, which splits the role of the nervous and musculoskeletal systems. Static optimization and dynamic optimization methods and electromyography-based approaches are summarized to highlight their limitations and understand (the need for) their developments over time. Then, the authors look at the more recent stochastic approach, introduced to explore the space of plausible neural solutions, thus implementing the uncontrolled manifold theory, according to which the central nervous system only controls specific motions and tasks to limit energy consumption while allowing for some degree of adaptability to perturbations. Finally, they explore the literature covering the explicit modeling of the coupling between the nervous system (acting as controller) and the musculoskeletal system (the actuator), which may be employed to overcome the split characterizing the reductionist approach.
Collapse
|
9
|
Credibility assessment of computational models according to ASME V&V40: Application to the Bologna Biomechanical Computed Tomography solution. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 240:107727. [PMID: 37523955 DOI: 10.1016/j.cmpb.2023.107727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 07/17/2023] [Accepted: 07/18/2023] [Indexed: 08/02/2023]
Abstract
BACKGROUND AND OBJECTIVE When a computational model aims to be adopted beyond research purposes, e.g. to inform a clinical or regulatory decision, trust must be placed in its predictive accuracy. This practically translates into the need to demonstrate its credibility. In fact, prior to its adoption for regulatory purposes, an in silico methodology should be proven credible enough for the scope. This has become especially relevant as, although evidence of the safety and efficacy of new medical products or interventions has been traditionally provided to the regulator experimentally, i.e., in vivo or ex vivo, recently the idea to inform a regulatory decision in silico has made its way in the regulatory scenario. While a harmonised technical standard is currently missing in the EU regulatory system, in 2018 the ASME issued V&V40-2018, where a risk-based framework to assess the credibility of a computational model through the performance of predefined credibility activities is provided. The credibility framework is here applied to Bologna Biomechanical Computed Tomography (BBCT) solution, which predicts the absolute risk of fracture at the femur for a subject. BBCT has recently been the object of a qualification advice request to the European Medicine Agency. METHODS The full implementation of ASME V&V40-2018 framework on BBCT is shown. Starting from BBCT proposed context of use the whole credibility plan is presented and the credibility activities (Verification, Validation, Applicability) described together with the achieved credibility levels. RESULTS BBCT risk is judged medium, and the credibility levels achieved considered acceptable. The uncertainties intrinsically present in the material properties assignment affected BBCT predictions to the highest extent. CONCLUSIONS This work provides the practical application of the ASME V&V40-2018 risk-based credibility assessment framework, which could be applied to demonstrate model credibility in any field and support future regulatory submissions and foster the adoption of In Silico Trials.
Collapse
|
10
|
Impact of previous lumbar spine surgery on total hip arthroplasty and vice versa: How long should we be concerned about mechanical failure? EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2023; 32:2949-2958. [PMID: 37498345 DOI: 10.1007/s00586-023-07866-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 06/13/2023] [Accepted: 07/11/2023] [Indexed: 07/28/2023]
Abstract
INTRODUCTION This registry study aims to assess the prevalence and demographic characteristics of patients with lumbar spine (LS) surgical procedures who undergo total hip arthroplasty (THA), to compare the long-term survival and causes of failure of THA in patients who previously underwent LS fusion and non-fusion surgical procedures, and to evaluate the risk of undergoing a revision LS surgery after THA. MATERIALS AND METHODS Patients who underwent LS surgery followed by THA were identified by cross-referencing data from the Orthopedic Prosthetic Implants Registry and the Regional Hospital Discharge Database. Three groups of THA patients were identified: patients who underwent previous lumbar surgery with fusion (LS fusion-THA), without fusion (LS non-fusion-THA), and a control group with only THA (No LS surgery-THA). Demographic data, THA survival, number and causes of failure, and data on revision procedures on THA and LS were collected. RESULTS Of the total of 79,984 THA, 2.2% of patients had a history of LS procedures. THA only patients showed better results, while patients in the LS fusion-THA group had worse implant survival at 5-year follow-up. In the LS fusion-THA and LS non-fusion-THA, mechanical THA failures were more frequent in the first two years after implantation. There were no differences between groups regarding the risk of undergoing LS revision surgery. CONCLUSIONS LS surgery negatively affects THA survivorship. In patients who previously underwent LS fusion and non-fusion surgical procedures, most THA failure occurs in the first two years after implant. The study contributes to the understanding of the relationship between the hip and the LS and provides useful guidance for clinical practice.
Collapse
|
11
|
Cost-Effectiveness Analysis of CT-Based Finite Element Modeling for Osteoporosis Screening in Secondary Fracture Prevention: An Early Health Technology Assessment in the Netherlands. MDM Policy Pract 2023; 8:23814683231202993. [PMID: 37900721 PMCID: PMC10605708 DOI: 10.1177/23814683231202993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Accepted: 08/20/2023] [Indexed: 10/31/2023] Open
Abstract
Objective. To conduct cost-utility analyses for Computed Tomography To Strength (CT2S), a novel osteoporosis screening service, compared with dual-energy X-ray absorptiometry (DXA), treat all without screening, and no screening methods for Dutch postmenopausal women referred to fracture liaison service (FLS). CT2S uses CT scans to generate femur models and simulate sideways fall scenarios for bone strength assessment. Methods. Early health technology assessment (HTA) was adopted to evaluate CT2S as a novel osteoporosis screening tool for secondary fracture prevention. We constructed a 2-dimensional simulation model considering 4 strategies (no screening, treat all without screening, DXA, CT2S) together with screening intervals (5 y, 2 y), treatments (oral alendronate, zoledronic acid), and discount rate scenarios among Dutch women in 3 age groups (60s, 70s, and 80s). Strategy comparisons were based on incremental cost-effectiveness ratios (ICERs), considering an ICER below €20,000 per QALY gained as cost-effective in the Netherlands. Results. Under the base-case scenario, CT2S versus DXA had estimated ICERs of €41,200 and €14,083 per QALY gained for the 60s and 70s age groups, respectively. For the 80s age group, CT2S was more effective and less costly than DXA. Changing treatment from weekly oral alendronate to annual zoledronic acid substantially decreased CT2S versus DXA ICERs across all age groups. Setting the screening interval to 2 y increased CT2S versus DXA ICERs to €100,333, €55,571, and €15,750 per QALY gained for the 60s, 70s, and 80s age groups, respectively. In all simulated populations and scenarios, CT2S was cost-effective (in some cases dominant) compared with the treat all strategy and cost-saving (more effective and less costly) compared with no screening. Conclusion. CT2S was estimated to be potentially cost-effective in the 70s and 80s age groups considering the willingness-to-pay threshold of the Netherlands. This early HTA suggests CT2S as a potential novel osteoporosis screening tool for secondary fracture prevention. Highlights For postmenopausal Dutch women who have been referred to the FLS, direct access to CT2S may be cost-effective compared with DXA for age groups 70s and 80s, when considering the ICER threshold of the Netherlands. This study positions CT2S as a potential novel osteoporosis-screening tool for secondary fracture prevention in the clinical setting.A shorter screening interval of 2 y increases the effectiveness of both screening strategies, but the ICER of CT2S compared with DXA also increased substantially, which made CT2S no longer cost-effective for the 70s age group; however, it remains cost-effective for individuals in their 80s.Annual zoledronic acid treatment with better adherence may contribute to a lower cost-effectiveness ratio when comparing CT2S to DXA screening and the treat all strategies for all age groups.
Collapse
|
12
|
Magnetic resonance-based hip muscles retrospective analysis shows deconditioning and recovery after total hip arthroplasty surgery. INTERNATIONAL ORTHOPAEDICS 2023; 47:1441-1447. [PMID: 36914844 DOI: 10.1007/s00264-023-05762-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 03/01/2023] [Indexed: 03/16/2023]
Abstract
PURPOSE The purpose of this study is to estimate the effect of unilateral hip osteoarthritis (OA) on hip muscle volume and fatty infiltration and to evaluate changes of muscles after total hip arthroplasty (THA) surgery. METHODS A retrospective analysis was conducted on patients with unilateral hip OA subjected to THA with perioperative pelvic girdle 1.5 T magnetic resonance imaging (MRI). Thirty-five patients were included. Ten of these have also postoperative MRIs. Medius gluteus (MG) and iliopsoas (IP) muscles were manually segmented on the MRI scans, the corresponding 3D muscle geometries were reconstructed, and the volumes extracted. Muscle quality was assessed using the Goutallier classification on coronal MRI images. Volume and muscle quality differences were calculated between healthy and affected side. RESULTS Pre-operatively, MG and IP on the affected side presented a mean muscle volume 17.5 ± 18% (p < 0.001) and 14.4 ± 15.8% (p < 0.001) smaller than the healthy counterpart, respectively. Muscles on the affected side showed a significant higher grade of fatty infiltration compared to the healthy side (p < 0.05 for MG; p < 0.001 for IP). At an average follow-up of 13 ± 5.3 months after THA, MG, and IP muscles of the affected hip showed an average 22.8% (p < 0.001) and 28.2% (p < 0.001) volume increase after THA. Also, the healthy side showed a significant increase of muscle volume for IP (17.1% p < 0.001). No significant change for MG muscle was observed. CONCLUSIONS The study demonstrated preoperative reduced muscle volume and higher fatty infiltration at the muscles of the OA hip compared to the contralateral healthy one. A significant positive effect of THA on hip muscle volume was observed. These findings give an interesting insight on muscle deconditioning and recovery in patients undergoing THA.
Collapse
|
13
|
Statistical Properties of a Virtual Cohort for In Silico Trials Generated with a Statistical Anatomy Atlas. Ann Biomed Eng 2023; 51:117-124. [PMID: 36066781 PMCID: PMC9832093 DOI: 10.1007/s10439-022-03050-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Accepted: 08/06/2022] [Indexed: 01/28/2023]
Abstract
Osteoporosis-related hip fragility fractures are a catastrophic event for patient lives but are not frequently observed in prospective studies, and therefore phase III clinical trials using fractures as primary clinical endpoint require thousands of patients enrolled for several years to reach statistical significance. A novel answer to the large number of subjects needed to reach the desired evidence level is offered by In Silico Trials, that is, the simulation of a clinical trial on a large cohort of virtual patients, monitoring the biomarkers of interest. In this work we investigated if statistical aliasing from a custom anatomy atlas could be used to expand the patient cohort while retaining the original biomechanical characteristics. We used a pair-matched cohort of 94 post-menopausal women (at the time of the CT scan, 47 fractured and 47 not fractured) to create a statistical anatomy atlas through principal component analysis, and up-sampled the atlas in order to obtain over 1000 synthetic patient models. We applied the biomechanical computed tomography pipeline to the resulting virtual cohort and compared its fracture risk distribution with that of the original physical cohort. While the distribution of femoral strength values in the non-fractured sub-group was nearly identical to that of the original physical cohort, that of the fractured sub-group was lower than in the physical cohort. Nonetheless, by using the classification threshold used for the original population, the synthetic population was still divided into two parts of approximatively equal number.
Collapse
|
14
|
A Credibility Assessment Plan for an In Silico Model that Predicts the Dose-Response Relationship of New Tuberculosis Treatments. Ann Biomed Eng 2023; 51:200-210. [PMID: 36115895 PMCID: PMC9483464 DOI: 10.1007/s10439-022-03078-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2022] [Accepted: 09/06/2022] [Indexed: 01/13/2023]
Abstract
Tuberculosis is one of the leading causes of death in several developing countries and a public health emergency of international concern. In Silico Trials can be used to support innovation in the context of drug development reducing the duration and the cost of the clinical experimentations, a particularly desirable goal for diseases such as tuberculosis. The agent-based Universal Immune System Simulator was used to develop an In Silico Trials environment that can predict the dose-response of new therapeutic vaccines against pulmonary tuberculosis, supporting the optimal design of clinical trials. But before such in silico methodology can be used in the evaluation of new treatments, it is mandatory to assess the credibility of this predictive model. This study presents a risk-informed credibility assessment plan inspired by the ASME V&V 40-2018 technical standard. Based on the selected context of use and regulatory impact of the technology, a detailed risk analysis is described together with the definition of all the verification and validation activities and related acceptability criteria. The work provides an example of the first steps required for the regulatory evaluation of an agent-based model used in the context of drug development.
Collapse
|
15
|
Effect of particularisation size on the accuracy and efficiency of a multiscale tumours' growth model. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2022; 38:e3657. [PMID: 36282099 DOI: 10.1002/cnm.3657] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 10/05/2022] [Indexed: 06/16/2023]
Abstract
In silico, medicine models are frequently used to represent a phenomenon across multiples space-time scales. Most of these multiscale models require impracticable execution times to be solved, even using high performance computing systems, because typically each representative volume element in the upper scale model is coupled to an instance of the lower scale model; this causes a combinatory explosion of the computational cost, which increases exponentially as the number of scales to be modelled increases. To attenuate this problem, it is a common practice to interpose between the two models a particularisation operator, which maps the upper-scale model results into a smaller number of lower-scale models, and an operator, which maps the fewer results of the lower-scale models on the whole space-time homogenisation domain of upper-scale model. The aim of this study is to explore what is the simplest particularisation / homogenisation scheme that can couple a model aimed to predict the growth of a whole solid tumour (neuroblastoma) to a tissue-scale model of the cell-tissue biology with an acceptable approximation error and a viable computational cost. Using an idealised initial dataset with spatial gradients representative of those of real neuroblastomas, but small enough to be solved without any particularisation, we determined the approximation error and the computational cost of a very simple particularisation strategy based on binning. We found that even such simple algorithm can significantly reduce the computational cost with negligible approximation errors.
Collapse
|
16
|
Lateral unicompartmental knee arthroplasty (UKA) showed a lower risk of failure compared to medial unicompartmental knee arthroplasty in the Register of Prosthetic Orthopedic Implants (RIPO). Arch Orthop Trauma Surg 2022; 143:3363-3368. [PMID: 36156122 DOI: 10.1007/s00402-022-04631-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2022] [Accepted: 09/18/2022] [Indexed: 02/09/2023]
Abstract
INTRODUCTION The present study aimed to investigate differences in survivorship between medial and lateral unicompartmental knee arthroplasty (UKA) by analyzing the data of an Italian regional registry. The hypothesis was that, according to recent literature, lateral implants have comparable survivorship with regard to the medial implants. MATERIALS AND METHODS The Register of Orthopaedic Prosthetic Implants (RIPO) of Emilia-Romagna (Italy) database was searched for all UKAs between July 1, 2000, and December 31, 2019. For both cohorts, subject demographics and reasons for revision were presented as a percentage of the total cohort. Kaplan-Meier survivorship analysis was performed using revision of any component as the endpoint and survival times of unrevised UKAs taken as the last observation date (December 31, 2019, or date of death). RESULTS Patients living outside the region and symmetrical implants (which do not allow the compartment operated to be traced) were excluded. 5571 UKAs implanted on 5172 patients (5215 medial UKAs and 356 lateral UKAs) were included in the study. The survivorship analysis revealed 13 failures out of 356 lateral UKAs (3.7%) at a mean follow-up of 6.3 years and 495 failures out of 5215 medial UKAs (9.5%) at a mean follow-up of 6.7 years. The medial UKAs had a significantly higher risk of failure, with a Hazard Ratio of 2.6 (CI 95% 1.6-4.8; p < 0.001), adjusted for age, gender, weight, and mobility of the insert. Both the groups revealed a good survival rate, with 95.2% of lateral implants and 87.5% of medial implants still in situ at 10 years of follow-up. CONCLUSIONS Lateral UKA is a safe procedure showing longer survivorship than medial UKAs (95.2% and 87.5% at 10 years, respectively) in the present study. LEVEL OF EVIDENCE Level 3, therapeutic study.
Collapse
|
17
|
On the use of wearable sensors as mobility biomarkers in the marketing authorization of new drugs: A regulatory perspective. Front Med (Lausanne) 2022; 9:996903. [PMID: 36213641 PMCID: PMC9533102 DOI: 10.3389/fmed.2022.996903] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Accepted: 09/01/2022] [Indexed: 11/13/2022] Open
Abstract
The loss of mobility is a common trait in multiple health conditions (e.g., Parkinson's disease) and is associated with reduced quality of life. In this context, being able to monitor mobility in the real world, is important. Until recently, the technology was not mature enough for this; but today, miniaturized sensors and novel algorithms promise to monitor mobility accurately and continuously in the real world, also in pathological populations. However, before any such methodology can be employed to support the development and testing of new drugs in clinical trials, they need to be qualified by the competent regulatory agencies (e.g., European Medicines Agency). Nonetheless, to date, only very narrow scoped requests for regulatory qualification were successful. In this work, the Mobilise-D Consortium shares its positive experience with the European regulator, summarizing the two requests for Qualification Advice for the Mobilise-D methodologies submitted in October 2019 and June 2020, as well as the feedback received, which resulted in two Letters of Support publicly available for consultation on the website of the European Medicines Agency. Leveraging on this experience, we hereby propose a refined qualification strategy for the use of digital mobility outcome (DMO) measures as monitoring biomarkers for mobility in drug trials.
Collapse
|
18
|
Toward a Regulatory Pathway for the Use of in Silico Trials in The Ce Marking of Medical Devices. IEEE J Biomed Health Inform 2022; 26:5282-5286. [PMID: 35951559 DOI: 10.1109/jbhi.2022.3198145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
In Silico Trials methodologies will play a growing and fundamental role in the development and de-risking of new medical devices in the future. While the regulatory pathway for Digital Patient and Personal Health Forecasting solutions is clear, it is more complex for In Silico Trials solutions, and therefore deserves a deeper analysis. In this position paper, we investigate the current state of the art towards the regulatory system for in silico trials applied to medical devices while exploring the European regulatory system toward this topic. We suggest that the European regulatory system should start a process of innovation: in principle to limit distorted quality by different internal processes within notified bodies, hence avoiding that the more innovative and competitive companies focus their attention on the needs of other large markets, like the USA, where the use of such radical innovations is already rapidly developing.
Collapse
|
19
|
A Theoretical Analysis of the Scale Separation in a Model to Predict Solid Tumour Growth. J Theor Biol 2022; 547:111173. [DOI: 10.1016/j.jtbi.2022.111173] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 03/27/2022] [Accepted: 05/19/2022] [Indexed: 11/27/2022]
|
20
|
Personalised 3D Assessment of Trochanteric Soft Tissues Improves HIP Fracture Classification Accuracy. Ann Biomed Eng 2022; 50:303-313. [PMID: 35103867 PMCID: PMC8847196 DOI: 10.1007/s10439-022-02924-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2021] [Accepted: 01/19/2022] [Indexed: 01/09/2023]
Abstract
Passive soft tissues surrounding the trochanteric region attenuate fall impact forces and thereby control hip fracture risk. The degree of attenuation is related to Soft Tissue Thickness (STT). STT at the neutral hip impact orientation, estimated using a regression relation in body mass index (BMI), was previously shown to influence the current absolute risk of hip fracture (ARF0) and its fracture classification accuracy. The present study investigates whether fracture classification using ARF0 improves when STT is determined from the subject’s Computed-Tomography (CT) scans (i.e. personalised) in an orientation-specific (i.e. 3D) manner. STT is calculated as the shortest distance along any impact orientation between a semi-automatically segmented femur surface and an automatically segmented soft tissue/air boundary. For any subject, STT along any of the 33 impact orientations analysed always exceeds the value estimated using BMI. Accuracy of fracture classification using ARF0 improves when using personalised 3D STT estimates (AUC = 0.87) instead of the BMI-based STT estimate (AUC = 0.85). The improvement is smaller (AUC = 0.86) when orientation-specificity of CT-based STT is suppressed and is nil when personalisation is suppressed instead. Thus, fracture classification using ARF0 improves when CT is used to personalise STT estimates and improves further when, in addition, the estimates are orientation specific.
Collapse
|
21
|
|
22
|
Computational modelling of the scoliotic spine: A literature review. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2021; 37:e3503. [PMID: 34114367 PMCID: PMC8518780 DOI: 10.1002/cnm.3503] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Revised: 05/26/2021] [Accepted: 06/04/2021] [Indexed: 06/12/2023]
Abstract
Scoliosis is a deformity of the spine that in severe cases requires surgical treatment. There is still disagreement among clinicians as to what the aim of such treatment is as well as the optimal surgical technique. Numerical models can aid clinical decision-making by estimating the outcome of a given surgical intervention. This paper provided some background information on the modelling of the healthy spine and a review of the literature on scoliotic spine models, their validation, and their application. An overview of the methods and techniques used to construct scoliotic finite element and multibody models was given as well as the boundary conditions used in the simulations. The current limitations of the models were discussed as well as how such limitations are addressed in non-scoliotic spine models. Finally, future directions for the numerical modelling of scoliosis were addressed.
Collapse
|
23
|
Delivering computationally-intensive digital patient applications to the clinic: An exemplar solution to predict femoral bone strength from CT data. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 208:106200. [PMID: 34107372 DOI: 10.1016/j.cmpb.2021.106200] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Accepted: 05/19/2021] [Indexed: 06/12/2023]
Abstract
BACKGROUND AND OBJECTIVE Whilst fragility hip fractures commonly affect elderly people, often causing permanent disability or death, they are rarely addressed in advance through preventive techniques. Quantification of bone strength can help to identify subjects at risk, thus reducing the incidence of fractures in the population. In recent years, researchers have shown that finite element models (FEMs) of the hip joint, derived from computed tomography (CT) images, can predict bone strength more accurately than other techniques currently used in the clinic. The specialised hardware and trained personnel required to perform such analyses, however, limits the widespread adoption of FEMs in clinical contexts. In this manuscript we present CT2S (Computed Tomography To Strength), a system developed in collaboration between The University of Sheffield and Sheffield Teaching Hospitals, designed to streamline access to this complex workflow for clinical end-users. METHODS The system relies on XNAT and makes use of custom apps based on open source software. Available through a website, it allows doctors in the healthcare environment to benefit from FE based bone strength estimation without being exposed to the technical aspects, which are concealed behind a user-friendly interface. Clinicians request the analysis of CT scans of a patient through the website. Using XNAT functionality, the anonymised images are automatically transferred to the University research facility, where an operator processes them and estimates the bone strength through FEM using a combination of open source and commercial software. Following the analysis, the doctor is provided with the results in a structured report. RESULTS The platform, currently available for research purposes, has been deployed and fully tested in Sheffield, UK. The entire analysis requires processing times ranging from 3.5 to 8 h, depending on the available computational power. CONCLUSIONS The short processing time makes the system compatible with current clinical workflows. The use of open source software and the accurate description of the workflow given here facilitates the deployment in other centres.
Collapse
|
24
|
Using Musculoskeletal Models to Estimate in vivo Total Knee Replacement Kinematics and Loads: Effect of Differences Between Models. Front Bioeng Biotechnol 2021; 9:703508. [PMID: 34395407 PMCID: PMC8357266 DOI: 10.3389/fbioe.2021.703508] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Accepted: 06/23/2021] [Indexed: 01/29/2023] Open
Abstract
Total knee replacement (TKR) is one of the most performed orthopedic surgeries to treat knee joint diseases in the elderly population. Although the survivorship of knee implants may extend beyond two decades, the poor outcome rate remains considerable. A recent computational approach used to better understand failure modes and improve TKR outcomes is based on the combination of musculoskeletal (MSK) and finite element models. This combined multiscale modeling approach is a promising strategy in the field of computational biomechanics; however, some critical aspects need to be investigated. In particular, the identification and quantification of the uncertainties related to the boundary conditions used as inputs to the finite element model due to a different definition of the MSK model are crucial. Therefore, the aim of this study is to investigate this problem, which is relevant for the model credibility assessment process. Three different generic MSK models available in the OpenSim platform were used to simulate gait, based on the experimental data from the fifth edition of the "Grand Challenge Competitions to Predict in vivo Knee Loads." The outputs of the MSK analyses were compared in terms of relative kinematics of the knee implant components and joint reaction (JR) forces and moments acting on the tibial insert. Additionally, the estimated knee JRs were compared with those measured by the instrumented knee implant so that the "global goodness of fit" was quantified for each model. Our results indicated that the different kinematic definitions of the knee joint and the muscle model implemented in the different MSK models influenced both the motion and the load history of the artificial joint. This study demonstrates the importance of examining the influence of the model assumptions on the output results and represents the first step for future studies that will investigate how the uncertainties in the MSK models propagate on disease-specific finite element model results.
Collapse
|
25
|
Verification of an agent-based disease model of human Mycobacterium tuberculosis infection. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2021; 37:e3470. [PMID: 33899348 PMCID: PMC8365724 DOI: 10.1002/cnm.3470] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Revised: 03/23/2021] [Accepted: 04/23/2021] [Indexed: 05/12/2023]
Abstract
Agent-based models (ABMs) are a powerful class of computational models widely used to simulate complex phenomena in many different application areas. However, one of the most critical aspects, poorly investigated in the literature, regards an important step of the model credibility assessment: solution verification. This study overcomes this limitation by proposing a general verification framework for ABMs that aims at evaluating the numerical errors associated with the model. A step-by-step procedure, which consists of two main verification studies (deterministic and stochastic model verification), is described in detail and applied to a specific mission critical scenario: the quantification of the numerical approximation error for UISS-TB, an ABM of the human immune system developed to predict the progression of pulmonary tuberculosis. Results provide indications on the possibility to use the proposed model verification workflow to systematically identify and quantify numerical approximation errors associated with UISS-TB and, in general, with any other ABMs.
Collapse
|
26
|
Possible Contexts of Use for In Silico trials methodologies: a consensus- based review. IEEE J Biomed Health Inform 2021; 25:3977-3982. [PMID: 34161248 DOI: 10.1109/jbhi.2021.3090469] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The term In Silico Trial indicates the use of computer modelling and simulation to evaluate the safety and efficacy of a medical product, whether a drug, a medical device, a diagnostic product or an advanced therapy medicinal product. Predictive models are positioned as new methodologies for the development and the regulatory evaluation of medical products. New methodologies are qualified by regulators such as FDA and EMA through formal processes, where a first step is the definition of the Context of Use (CoU), which is a concise description of how the new methodology is intended to be used in the development and regulatory assessment process. As In Silico Trials are a disruptively innovative class of new methodologies, it is important to have a list of possible CoUs highlighting potential applications for the development of the relative regulatory science. This review paper presents the result of a consensus process that took place in the InSilicoWorld Community of Practice, an online forum for experts in in silico medicine. The experts involved identified 46 descriptions of possible CoUs which were organised into a candidate taxonomy of nine CoU categories. Examples of 31 CoUs were identified in the available literature; the remaining 15 should, for now, be considered speculative.
Collapse
|
27
|
Effect of Suboptimal Neuromuscular Control on the Risk of Massive Wear in Total Knee Replacement. Ann Biomed Eng 2021; 49:3349-3355. [PMID: 34076785 PMCID: PMC8671275 DOI: 10.1007/s10439-021-02795-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Accepted: 05/12/2021] [Indexed: 11/21/2022]
Abstract
The optimal neuromuscular control (muscle activation strategy that minimises the consumption of metabolic energy) during level walking is very close to that which minimises the force transmitted through the joints of the lower limbs. Thus, any suboptimal control involves an overloading of the joints. Some total knee replacement patients adopt suboptimal control strategies during level walking; this is particularly true for patients with co-morbidities that cause neuromotor control degeneration, such as Parkinson’s Disease (PD). The increase of joint loading increases the risk of implant failure, as reported in one study in PD patients (5.44% of failures at 9 years follow-up). One failure mode that is directly affected by joint loading is massive wear of the prosthetic articular surface. In this study we used a validated patient-specific biomechanical model to estimate how a severely suboptimal control could increase the wear rate of total knee replacements. Whereas autopsy-retrieved implants from non-PD patients typically show average polyethylene wear of 17 mm3 per year, our simulations suggested that a severely suboptimal control could cause a wear rate as high as of 69 mm3 per year. Assuming the risk of implant failure due to massive wear increase linearly with the wear rate, a severely suboptimal control could increase the risk associated to that failure mode from 0.1% to 0.5%. Based on these results, such increase would not be not sufficient to justify alone the higher incidence rate of revision in patients affected by Parkinson’s Disease, suggesting that other failure modes may be involved.
Collapse
|
28
|
A systematic approach to the scale separation problem in the development of multiscale models. PLoS One 2021; 16:e0251297. [PMID: 34003842 PMCID: PMC8130972 DOI: 10.1371/journal.pone.0251297] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Accepted: 04/25/2021] [Indexed: 11/19/2022] Open
Abstract
Throughout engineering there are problems where it is required to predict a quantity based on the measurement of another, but where the two quantities possess characteristic variations over vastly different ranges of time and space. Among the many challenges posed by such 'multiscale' problems, that of defining a 'scale' remains poorly addressed. This fundamental problem has led to much confusion in the field of biomedical engineering in particular. The present study proposes a definition of scale based on measurement limitations of existing instruments, available computational power, and on the ranges of time and space over which quantities of interest vary characteristically. The definition is used to construct a multiscale modelling methodology from start to finish, beginning with a description of the system (portion of reality of interest) and ending with an algorithmic orchestration of mathematical models at different scales within the system. The methodology is illustrated for a specific but well-researched problem. The concept of scale and the multiscale modelling approach introduced are shown to be easily adaptable to other closely related problems. Although out of the scope of this paper, we believe that the proposed methodology can be applied widely throughout engineering.
Collapse
|
29
|
Abstract
AIMS Total hip arthroplasty (THA) patients undergoing or having a prior lumbar spine fusion (LSF) have an increased risk of mechanical complications. The aim of this registry-based, retrospective comparative cohort study is to assess the longer term survival of THA in patients who have undergone a LSF during a 17-year period (2000 to 2017). METHODS A registry-based population study was conducted on 679 patients who underwent both THA and LSF surgeries. Patients were identified from the regional arthroplasty data base and cross linked to patients with LSF from the regional hospital discharge database between 2000 and 2017. Demographic data, diagnosis leading to primary THA, primary implant survival, perioperative complications, number and causes of failure, and patients requiring revision arthroplasty were collated and compared. For comparison, data from 67,919 primary THAs performed during the same time time period were also retrieved and analyzed. RESULTS Patients undergoing THA and LSF showed homogeneous demographic data compared to those undergoing THA alone, but a significantly lower eight-year THA implant survival (96.7 vs 96.0, p = 0.024) was observed. Moreover, THA plus LSF patients showed increased incidence of mechanical complications in the first two years after THA surgery compared to THA alone patients. CONCLUSION This registry-based population study shows that approximately 679 (1%) THA patients were subjected to LSF. Patients undergoing THA and LSF have an increased risk of mechanical complications with their THA and a slightly increased risk of revision arthroplasty. Cite this article: Bone Joint J 2021;103-B(3):486-491.
Collapse
|
30
|
Femoral neck strain prediction during level walking using a combined musculoskeletal and finite element model approach. PLoS One 2021; 16:e0245121. [PMID: 33524024 PMCID: PMC7850486 DOI: 10.1371/journal.pone.0245121] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Accepted: 12/22/2020] [Indexed: 01/19/2023] Open
Abstract
Recently, coupled musculoskeletal-finite element modelling approaches have emerged as a way to investigate femoral neck loading during various daily activities. Combining personalised gait data with finite element models will not only allow us to study changes in motion/movement, but also their effects on critical internal structures, such as the femur. However, previous studies have been hampered by the small sample size and the lack of fully personalised data in order to construct the coupled model. Therefore, the aim of this study was to build a pipeline for a fully personalised multiscale (body-organ level) model to investigate the strain levels at the femoral neck during a normal gait cycle. Five postmenopausal women were included in this study. The CT and MRI scans of the lower limb, and gait data were collected for all participants. Muscle forces derived from the body level musculoskeletal models were used as boundary constraints on the finite element femur models. Principal strains were estimated at the femoral neck region during a full gait cycle. Considerable variation was found in the predicted peak strain among individuals with mean peak first principal strain of 0.24% ± 0.11% and mean third principal strain of -0.29% ± 0.24%. For four individuals, two overall peaks of the maximum strains were found to occur when both feet were in contact with the floor, while one individual had one peak at the toe-off phase. Both the joint contact forces and the muscular forces were found to substantially influence the loading at the femoral neck. A higher correlation was found between the predicted peak strains and the gluteus medius (R2 ranged between 0.95 and 0.99) than the hip joint contact forces (R2 ranged between 0.63 and 0.96). Therefore, the current findings suggest that personal variations are substantial, and hence it is important to consider multiple subjects before deriving general conclusions for a target population.
Collapse
|
31
|
Evaluation of patient tissue selection methods for deriving equivalent density calibration for femoral bone quantitative CT analyses. Bone 2021; 143:115759. [PMID: 33212317 DOI: 10.1016/j.bone.2020.115759] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Revised: 10/30/2020] [Accepted: 11/13/2020] [Indexed: 01/22/2023]
Abstract
Osteoporosis affects an increasing number of people every year and patient specific finite element analysis of the femur has been proposed to identify patients that could benefit from preventative treatment. The aim of this study was to demonstrate, verify, and validate an objective process for selecting tissues for use as the basis of phantomless calibration to enable patient specific finite element analysis derived hip fracture risk prediction. Retrospective reanalysis of patient computed tomography (CT) scans has the potential to yield insights into more accurate prediction of osteoporotic fracture. Bone mineral density (BMD) specific calibration scans are not typically captured during routine clinical practice. Tissue-based BMD calibration can therefore empower the retrospective study of patient CT scans captured during routine clinical practice. Together the method for selecting tissues as the basis for phantomless calibration coupled with the post-processing steps for deriving a calibration equation using the selected tissues provide an estimation of quantitative equivalent density results derived using calibration phantoms. Patient tissues from a retrospective cohort of 211 patients were evaluated. The best phantomless calibration resulted in a femoral strength (FS) [N] bias of 0.069 ± 0.07% over FS derived from inline calibration and a BMD [kg/cm3] bias of 0.038 ± 0.037% over BMD derived from inline calibration. The phantomless calibration slope for the best method presented was within the range of patient specific calibration curves available for comparison and demonstrated a small bias of 0.028 ± 0.054 HU/(mg/cm3), assuming the Mindways Model 3 BMD inline calibration phantom as the gold standard. The presented method of estimating a calibration equation from tissues showed promise for CT-based femoral fracture analyses of retrospective cohorts without readily available calibration data.
Collapse
|
32
|
Generation of digital patients for the simulation of tuberculosis with UISS-TB. BMC Bioinformatics 2020; 21:449. [PMID: 33308156 PMCID: PMC7733699 DOI: 10.1186/s12859-020-03776-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Accepted: 09/22/2020] [Indexed: 01/11/2023] Open
Abstract
BACKGROUND The STriTuVaD project, funded by Horizon 2020, aims to test through a Phase IIb clinical trial one of the most advanced therapeutic vaccines against tuberculosis. As part of this initiative, we have developed a strategy for generating in silico patients consistent with target population characteristics, which can then be used in combination with in vivo data on an augmented clinical trial. RESULTS One of the most challenging tasks for using virtual patients is developing a methodology to reproduce biological diversity of the target population, ie, providing an appropriate strategy for generating libraries of digital patients. This has been achieved through the creation of the initial immune system repertoire in a stochastic way, and through the identification of a vector of features that combines both biological and pathophysiological parameters that personalise the digital patient to reproduce the physiology and the pathophysiology of the subject. CONCLUSIONS We propose a sequential approach to sampling from the joint features population distribution in order to create a cohort of virtual patients with some specific characteristics, resembling the recruitment process for the target clinical trial, which then can be used for augmenting the information from the physical the trial to help reduce its size and duration.
Collapse
|
33
|
Moving forward through the in silico modeling of tuberculosis: a further step with UISS-TB. BMC Bioinformatics 2020; 21:458. [PMID: 33308139 PMCID: PMC7733696 DOI: 10.1186/s12859-020-03762-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Accepted: 09/17/2020] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND In 2018, about 10 million people were found infected by tuberculosis, with approximately 1.2 million deaths worldwide. Despite these numbers have been relatively stable in recent years, tuberculosis is still considered one of the top 10 deadliest diseases worldwide. Over the years, Mycobacterium tuberculosis has developed a form of resistance to first-line tuberculosis treatments, specifically to isoniazid, leading to multi-drug-resistant tuberculosis. In this context, the EU and Indian DBT funded project STriTuVaD-In Silico Trial for Tuberculosis Vaccine Development-is supporting the identification of new interventional strategies against tuberculosis thanks to the use of Universal Immune System Simulator (UISS), a computational framework capable of predicting the immunity induced by specific drugs such as therapeutic vaccines and antibiotics. RESULTS Here, we present how UISS accurately simulates tuberculosis dynamics and its interaction within the immune system, and how it predicts the efficacy of the combined action of isoniazid and RUTI vaccine in a specific digital population cohort. Specifically, we simulated two groups of 100 digital patients. The first group was treated with isoniazid only, while the second one was treated with the combination of RUTI vaccine and isoniazid, according to the dosage strategy described in the clinical trial design. UISS-TB shows to be in good agreement with clinical trial results suggesting that RUTI vaccine may favor a partial recover of infected lung tissue. CONCLUSIONS In silico trials innovations represent a powerful pipeline for the prediction of the effects of specific therapeutic strategies and related clinical outcomes. Here, we present a further step in UISS framework implementation. Specifically, we found that the simulated mechanism of action of RUTI and INH are in good alignment with the results coming from past clinical phase IIa trials.
Collapse
|
34
|
In silico trial to test COVID-19 candidate vaccines: a case study with UISS platform. BMC Bioinformatics 2020; 21:527. [PMID: 33308153 PMCID: PMC7733700 DOI: 10.1186/s12859-020-03872-0] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Accepted: 11/09/2020] [Indexed: 02/07/2023] Open
Abstract
Background SARS-CoV-2 is a severe respiratory infection that infects humans. Its outburst entitled it as a pandemic emergence. To get a grip on this outbreak, specific preventive and therapeutic interventions are urgently needed. It must be said that, until now, there are no existing vaccines for coronaviruses. To promptly and rapidly respond to pandemic events, the application of in silico trials can be used for designing and testing medicines against SARS-CoV-2 and speed-up the vaccine discovery pipeline, predicting any therapeutic failure and minimizing undesired effects. Results We present an in silico platform that showed to be in very good agreement with the latest literature in predicting SARS-CoV-2 dynamics and related immune system host response. Moreover, it has been used to predict the outcome of one of the latest suggested approach to design an effective vaccine, based on monoclonal antibody. Universal Immune System Simulator (UISS) in silico platform is potentially ready to be used as an in silico trial platform to predict the outcome of vaccination strategy against SARS-CoV-2. Conclusions In silico trials are showing to be powerful weapons in predicting immune responses of potential candidate vaccines. Here, UISS has been extended to be used as an in silico trial platform to speed-up and drive the discovery pipeline of vaccine against SARS-CoV-2.
Collapse
|
35
|
Computational biomedicine. Part II: organs and systems. Interface Focus 2020. [DOI: 10.1098/rsfs.2020.0082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
36
|
A Roadmap to Inform Development, Validation and Approval of Digital Mobility Outcomes: The Mobilise-D Approach. Digit Biomark 2020; 4:13-27. [PMID: 33442578 DOI: 10.1159/000512513] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Accepted: 10/23/2020] [Indexed: 12/19/2022] Open
Abstract
Health care has had to adapt rapidly to COVID-19, and this in turn has highlighted a pressing need for tools to facilitate remote visits and monitoring. Digital health technology, including body-worn devices, offers a solution using digital outcomes to measure and monitor disease status and provide outcomes meaningful to both patients and health care professionals. Remote monitoring of physical mobility is a prime example, because mobility is among the most advanced modalities that can be assessed digitally and remotely. Loss of mobility is also an important feature of many health conditions, providing a read-out of health as well as a target for intervention. Real-world, continuous digital measures of mobility (digital mobility outcomes or DMOs) provide an opportunity for novel insights into health care conditions complementing existing mobility measures. Accepted and approved DMOs are not yet widely available. The need for large collaborative efforts to tackle the critical steps to adoption is widely recognised. Mobilise-D is an example. It is a multidisciplinary consortium of 34 institutions from academia and industry funded through the European Innovative Medicines Initiative 2 Joint Undertaking. Members of Mobilise-D are collaborating to address the critical steps for DMOs to be adopted in clinical trials and ultimately health care. To achieve this, the consortium has developed a roadmap to inform the development, validation and approval of DMOs in Parkinson's disease, multiple sclerosis, chronic obstructive pulmonary disease and recovery from proximal femoral fracture. Here we aim to describe the proposed approach and provide a high-level view of the ongoing and planned work of the Mobilise-D consortium. Ultimately, Mobilise-D aims to stimulate widespread adoption of DMOs through the provision of device agnostic software, standards and robust validation in order to bring digital outcomes from concept to use in clinical trials and health care.
Collapse
|
37
|
The Uncontrolled Manifold Theory Could Explain Part of the Inter-Trial Variability of Knee Contact Force During Level Walking. IEEE Trans Neural Syst Rehabil Eng 2020; 28:1800-1807. [DOI: 10.1109/tnsre.2020.3003559] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
38
|
In silico clinical trials: concepts and early adoptions. Brief Bioinform 2020; 20:1699-1708. [PMID: 29868882 DOI: 10.1093/bib/bby043] [Citation(s) in RCA: 98] [Impact Index Per Article: 24.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Revised: 04/18/2018] [Indexed: 02/07/2023] Open
Abstract
Innovations in information and communication technology infuse all branches of science, including life sciences. Nevertheless, healthcare is historically slow in adopting technological innovation, compared with other industrial sectors. In recent years, new approaches in modelling and simulation have started to provide important insights in biomedicine, opening the way for their potential use in the reduction, refinement and partial substitution of both animal and human experimentation. In light of this evidence, the European Parliament and the United States Congress made similar recommendations to their respective regulators to allow wider use of modelling and simulation within the regulatory process. In the context of in silico medicine, the term 'in silico clinical trials' refers to the development of patient-specific models to form virtual cohorts for testing the safety and/or efficacy of new drugs and of new medical devices. Moreover, it could be envisaged that a virtual set of patients could complement a clinical trial (reducing the number of enrolled patients and improving statistical significance), and/or advise clinical decisions. This article will review the current state of in silico clinical trials and outline directions for a full-scale adoption of patient-specific modelling and simulation in the regulatory evaluation of biomedical products. In particular, we will focus on the development of vaccine therapies, which represents, in our opinion, an ideal target for this innovative approach.
Collapse
|
39
|
PRIMAGE project: predictive in silico multiscale analytics to support childhood cancer personalised evaluation empowered by imaging biomarkers. Eur Radiol Exp 2020; 4:22. [PMID: 32246291 PMCID: PMC7125275 DOI: 10.1186/s41747-020-00150-9] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Accepted: 02/24/2020] [Indexed: 03/12/2023] Open
Abstract
PRIMAGE is one of the largest and more ambitious research projects dealing with medical imaging, artificial intelligence and cancer treatment in children. It is a 4-year European Commission-financed project that has 16 European partners in the consortium, including the European Society for Paediatric Oncology, two imaging biobanks, and three prominent European paediatric oncology units. The project is constructed as an observational in silico study involving high-quality anonymised datasets (imaging, clinical, molecular, and genetics) for the training and validation of machine learning and multiscale algorithms. The open cloud-based platform will offer precise clinical assistance for phenotyping (diagnosis), treatment allocation (prediction), and patient endpoints (prognosis), based on the use of imaging biomarkers, tumour growth simulation, advanced visualisation of confidence scores, and machine-learning approaches. The decision support prototype will be constructed and validated on two paediatric cancers: neuroblastoma and diffuse intrinsic pontine glioma. External validation will be performed on data recruited from independent collaborative centres. Final results will be available for the scientific community at the end of the project, and ready for translation to other malignant solid tumours.
Collapse
|
40
|
Effect of size and location of simulated lytic lesions on the structural properties of human vertebral bodies, a micro-finite element study. Bone Rep 2020; 12:100257. [PMID: 32551335 PMCID: PMC7292861 DOI: 10.1016/j.bonr.2020.100257] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 01/07/2020] [Accepted: 03/06/2020] [Indexed: 11/25/2022] Open
Abstract
Currently, the Spinal Instability Neoplastic Score system is used in clinics to evaluate the risk of fracture in patients with spinal metastases. This method, however, does not always provide a clear guideline due to the complexity in accounting for the effect of metastatic lesions on vertebral stability. The aim of this study was to use a validated micro Finite Element (microFE) modelling approach to analyse the effect of the size and location of lytic metastases on the mechanical properties of human vertebral bodies. Micro Computed Tomography based microFE models were generated with and without lytic lesions simulated as holes within a human vertebral body. Single and multiple lytic lesions were simulated with four different sizes and in five different locations. Bone was assumed homogenous, isotropic and linear elastic, and each vertebra was loaded in axial compression. It was observed that the size of lytic lesions was linearly related with the reduction in structural properties of the vertebral body (reduction of stiffness between 3% and 30% for lesion volume between 4% and 35%). The location of lytic lesions did not show a clear effect on predicted structural properties. Single or multiple lesions with the same volume provided similar results. Locally, there was a homogeneous distribution of axial principal strains among the models with and without lytic lesions. This study highlights the potential of microFE models to study the effect of lesions on the mechanical properties of the human vertebral body. MicroFE models can show the effect of lytic lesions on vertebral properties. The size of the lesions was more critical than the location of the lesions. Lesions affecting the cortical shell had a larger effect on the local strains. Multiple lesions showed a similar effect to single lesions.
Collapse
|
41
|
An extended discrete element method for the estimation of contact pressure at the ankle joint during stance phase. Proc Inst Mech Eng H 2020; 234:507-516. [PMID: 32036769 PMCID: PMC7469707 DOI: 10.1177/0954411920905434] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Abnormalities in the ankle contact pressure are related to the onset of osteoarthritis. In vivo measurements are not possible with currently available techniques, so computational methods such as the finite element analysis (FEA) are often used instead. The discrete element method (DEM), a computationally efficient alternative to time-consuming FEA, has also been used to predict the joint contact pressure. It describes the articular cartilage as a bed of independent springs, assuming a linearly elastic behaviour and absence of relative motion between the bones. In this study, we present the extended DEM (EDEM) which is able to track the motion of talus over time. The method was used, with input data from a subject-specific musculoskeletal model, to predict the contact pressure in the ankle joint during gait. Results from EDEM were also compared with outputs from conventional DEM. Predicted values of contact area were larger in EDEM than they were in DEM (4.67 and 4.18 cm2, respectively). Peak values of contact pressure, attained at the toe-off, were 7.3 MPa for EDEM and 6.92 MPa for DEM. Values predicted from EDEM fell well within the ranges reported in the literature. Overall, the motion of the talus had more effect on the extension and shape of the pressure distribution than it had on the magnitude of the pressure. The results indicated that EDEM is a valid methodology for the prediction of ankle contact pressure during daily activities.
Collapse
|
42
|
In silico trials: Verification, validation and uncertainty quantification of predictive models used in the regulatory evaluation of biomedical products. Methods 2020; 185:120-127. [PMID: 31991193 PMCID: PMC7883933 DOI: 10.1016/j.ymeth.2020.01.011] [Citation(s) in RCA: 92] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Revised: 11/10/2019] [Accepted: 01/14/2020] [Indexed: 02/03/2023] Open
Abstract
Regulators now consider also evidences produced in silico. We need accepted methods to evaluate the credibility of models. In this paper we describe the use of the ASME V&V-40 technical standard. We also discuss its application to various types of modelling methods.
Historically, the evidences of safety and efficacy that companies provide to regulatory agencies as support to the request for marketing authorization of a new medical product have been produced experimentally, either in vitro or in vivo. More recently, regulatory agencies started receiving and accepting evidences obtained in silico, i.e. through modelling and simulation. However, before any method (experimental or computational) can be acceptable for regulatory submission, the method itself must be considered “qualified” by the regulatory agency. This involves the assessment of the overall “credibility” that such a method has in providing specific evidence for a given regulatory procedure. In this paper, we describe a methodological framework for the credibility assessment of computational models built using mechanistic knowledge of physical and chemical phenomena, in addition to available biological and physiological knowledge; these are sometimes referred to as “biophysical” models. Using guiding examples, we explore the definition of the context of use, the risk analysis for the definition of the acceptability thresholds, and the various steps of a comprehensive verification, validation and uncertainty quantification process, to conclude with considerations on the credibility of a prediction for a specific context of use. While this paper does not provide a guideline for the formal qualification process, which only the regulatory agencies can provide, we expect it to help researchers to better appreciate the extent of scrutiny required, which should be considered early on in the development/use of any (new) in silico evidence.
Collapse
|
43
|
Predicting the artificial immunity induced by RUTI® vaccine against tuberculosis using universal immune system simulator (UISS). BMC Bioinformatics 2019; 20:504. [PMID: 31822272 PMCID: PMC6904993 DOI: 10.1186/s12859-019-3045-5] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Accepted: 08/21/2019] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Tuberculosis (TB) represents a worldwide cause of mortality (it infects one third of the world's population) affecting mostly developing countries, including India, and recently also developed ones due to the increased mobility of the world population and the evolution of different new bacterial strains capable to provoke multi-drug resistance phenomena. Currently, antitubercular drugs are unable to eradicate subpopulations of Mycobacterium tuberculosis (MTB) bacilli and therapeutic vaccinations have been postulated to overcome some of the critical issues related to the increase of drug-resistant forms and the difficult clinical and public health management of tuberculosis patients. The Horizon 2020 EC funded project "In Silico Trial for Tuberculosis Vaccine Development" (STriTuVaD) to support the identification of new therapeutic interventions against tuberculosis through novel in silico modelling of human immune responses to disease and vaccines, thereby drastically reduce the cost of clinical trials in this critical sector of public healthcare. RESULTS We present the application of the Universal Immune System Simulator (UISS) computational modeling infrastructure as a disease model for TB. The model is capable to simulate the main features and dynamics of the immune system activities i.e., the artificial immunity induced by RUTI® vaccine, a polyantigenic liposomal therapeutic vaccine made of fragments of Mycobacterium tuberculosis cells (FCMtb). Based on the available data coming from phase II Clinical Trial in subjects with latent tuberculosis infection treated with RUTI® and isoniazid, we generated simulation scenarios through validated data in order to tune UISS accordingly to STriTuVaD objectives. The first case simulates the establishment of MTB latent chronic infection with some typical granuloma formation; the second scenario deals with a reactivation phase during latent chronic infection; the third represents the latent chronic disease infection scenario during RUTI® vaccine administration. CONCLUSIONS The application of this computational modeling strategy helpfully contributes to simulate those mechanisms involved in the early stages and in the progression of tuberculosis infection and to predict how specific therapeutical strategies will act in this scenario. In view of these results, UISS owns the capacity to open the door for a prompt integration of in silico methods within the pipeline of clinical trials, supporting and guiding the testing of treatments in patients affected by tuberculosis.
Collapse
|
44
|
Correction to: Are CT-Based Finite Element Model Predictions of Femoral Bone Strength Clinically Useful? Curr Osteoporos Rep 2019; 17:580. [PMID: 29934754 PMCID: PMC7050568 DOI: 10.1007/s11914-018-0466-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The original version "Are CT-Based Finite Element Model Predictions of Femoral Bone Strengthening Clinically Useful?"
Collapse
|
45
|
Linking Joint Impairment and Gait Biomechanics in Patients with Juvenile Idiopathic Arthritis. Ann Biomed Eng 2019; 47:2155-2167. [PMID: 31111329 PMCID: PMC6838035 DOI: 10.1007/s10439-019-02287-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2019] [Accepted: 05/08/2019] [Indexed: 11/27/2022]
Abstract
Juvenile Idiopathic Arthritis (JIA) is a paediatric musculoskeletal disease of unknown aetiology, leading to walking alterations when the lower-limb joints are involved. Diagnosis of JIA is mostly clinical. Imaging can quantify impairments associated to inflammation and joint damage. However, treatment planning could be better supported using dynamic information, such as joint contact forces (JCFs). To this purpose, we used a musculoskeletal model to predict JCFs and investigate how JCFs varied as a result of joint impairment in eighteen children with JIA. Gait analysis data and magnetic resonance images (MRI) were used to develop patient-specific lower-limb musculoskeletal models, which were evaluated for operator-dependent variability (< 3.6°, 0.05 N kg-1 and 0.5 BW for joint angles, moments, and JCFs, respectively). Gait alterations and JCF patterns showed high between-subjects variability reflecting the pathology heterogeneity in the cohort. Higher joint impairment, assessed with MRI-based evaluation, was weakly associated to overall joint overloading. A stronger correlation was observed between impairment of one limb and overload of the contralateral limb, suggesting risky compensatory strategies being adopted, especially at the knee level. This suggests that knee overloading during gait might be a good predictor of disease progression and gait biomechanics should be used to inform treatment planning.
Collapse
|
46
|
Abstract
Different research communities have developed various approaches to assess the credibility of predictive models. Each approach usually works well for a specific type of model, and under some epistemic conditions that are normally satisfied within that specific research domain. Some regulatory agencies recently started to consider evidences of safety and efficacy on new medical products obtained using computer modelling and simulation (which is referred to as In Silico Trials); this has raised the attention in the computational medicine research community on the regulatory science aspects of this emerging discipline. But this poses a foundational problem: in the domain of biomedical research the use of computer modelling is relatively recent, without a widely accepted epistemic framing for model credibility. Also, because of the inherent complexity of living organisms, biomedical modellers tend to use a variety of modelling methods, sometimes mixing them in the solution of a single problem. In such context merely adopting credibility approaches developed within other research communities might not be appropriate. In this paper we propose a theoretical framing for assessing the credibility of a predictive models for In Silico Trials, which accounts for the epistemic specificity of this research field and is general enough to be used for different type of models.
Collapse
|
47
|
Predicting bone strength from CT data: Clinical applications. Morphologie 2019; 103:180-186. [PMID: 31630964 DOI: 10.1016/j.morpho.2019.09.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Accepted: 09/17/2019] [Indexed: 10/25/2022]
Abstract
In this review we summarise over 15 years of research and development around the prediction of whole bones strength from Computed Tomography data, with particular reference to the prediction of the risk of hip fracture in osteoporotic patients. We briefly discuss the theoretical background, and then provide a summary of the laboratory and clinical validation of these modelling technologies. We then discuss the three current clinical applications: in clinical research, in clinical trials, and in clinical practice. On average the strength predicted with finite element models (QCT-FE) based on computed tomography is 7% more accurate that that predicted with areal bone mineral density from Dual X-ray Absorptiometry (DXA-aBMD), the current standard of care, both in term of laboratory validation on cadaver bones and in terms of stratification accuracy on clinical cohorts of fractured and non-fractured women. This improved accuracy makes QCT-FE superior to DXA-aBMD in clinical research and in clinical trials, where the its use can cut in half the number of patients to be enrolled to get the same statistical power. For routine clinical use to decide who to treat with antiresorptive drugs, QCT-FE is more accurate but less cost-effective than DXA-aBMD, at least when the decision is on first line treatment like bisphosphonates. But the ability to predict skeletal strength from medical imaging is now opening a number of other applications, for example in paediatrics and oncology.
Collapse
|
48
|
Investigating rolling as mechanism for humeral fractures in non-ambulant infants: a preliminary finite element study. Clin Radiol 2019; 75:78.e9-78.e16. [PMID: 31590914 DOI: 10.1016/j.crad.2019.08.026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Accepted: 08/29/2019] [Indexed: 11/27/2022]
Abstract
AIM To use personalised computed tomography (CT)-based finite element models to quantitatively investigate the likelihood of self-inflicted humeral fracture in non-ambulant infants secondary to rolling. MATERIALS AND METHODS Three whole-body post-mortem CT examinations of children at the age of rolling (two 4-month-old and one 6-month-old) were used. The mechanical moment needed by each infant to perform a rolling manoeuvre was calculated and applied to the finite element model in order to simulate spontaneous rolling from the prone to the supine position. RESULTS The maximum predicted strains were found to be substantially lower (with a difference of >80%) than the elastic limit of the bone. CONCLUSION Results of this study challenge the plausibility of self-inflicted humeral fracture caused by rolling in non-ambulant infants and indicate that it is unlikely for a humeral fracture to result from this mechanism without the assistance of an external force.
Collapse
|
49
|
Biomechanical assessment of vertebrae with lytic metastases with subject-specific finite element models. J Mech Behav Biomed Mater 2019; 98:268-290. [DOI: 10.1016/j.jmbbm.2019.06.027] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 06/18/2019] [Accepted: 06/27/2019] [Indexed: 12/25/2022]
|
50
|
Muscle recruitment strategies can reduce joint loading during level walking. J Biomech 2019; 97:109368. [PMID: 31606129 DOI: 10.1016/j.jbiomech.2019.109368] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2019] [Revised: 09/18/2019] [Accepted: 09/22/2019] [Indexed: 10/25/2022]
Abstract
Joint inflammation, with consequent cartilage damage and pain, typically reduces functionality and affects activities of daily life in a variety of musculoskeletal diseases. Since mechanical loading is an important determinant of the disease process, a possible conservative treatment is the unloading of joints. In principle, a neuromuscular rehabilitation program aimed to promote alternative muscle recruitments could reduce the loads on the lower-limb joints during walking. The extent of joint load reduction one could expect from this approach remains unknown. Furthermore, assuming significant reductions of the load on the affected joint can be achieved, it is unclear whether, and to what extent, the other joints will be overloaded. Using subject-specific musculoskeletal models of four different participants, we computed the muscle recruitment strategies that minimised the hip, knee and ankle contact force, and predicted the contact forces such strategies induced at the other joints. Significant reductions of the peak force and impulse at the knee and hip were obtained, while only a minimal effect was found at the ankle joint. Adversely, the peak force and the impulse in non-targeted joints increased when aiming to minimize the load in an adjacent joint. These results confirm the potential of alternative muscle recruitment strategies to reduce the loading at the knee and the hip, but not at the ankle. Therefore, neuromuscular rehabilitation can be targeted to reduce the loading at affected joints but must be considered carefully in patients with multiple joints affected due to the potential adverse effects in non-targeted joints.
Collapse
|