1
|
[Bioinformatics-based analysis of the effect of general Transcription Factor IIH on prognosis of Prostate cancer]. ZHONGHUA YI XUE ZA ZHI 2024; 104:1410-1417. [PMID: 38644292 DOI: 10.3760/cma.j.cn112137-20231228-01504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 04/23/2024]
Abstract
Objective: To investigate the genetic and expression characteristics of transcription factor IIH (TFIIH) in pre-initiationcomplex in prostate cancer (PCa) and its relationship with prostate cancer progression. Methods: Analyzing the expression characteristics and clinical signification of TFIIH subunits about 495 cases of PCa and 52 cases of adjacent cancer in The Cancer Genome Atlas-Prostate adenocarcinoma (TCGA-PRAD) database. PCa microarray chip was used to verify the correlation between the key factor General Transcription Factor IIH Subunit 4 (GTF2H4) in TFIIH and clinical features. Results: The 495 patients with PCa were (61.01±6.82) years old.The mRNA expression of ERCC3、GTF2H4 and MNAT1 were high in PCa tissues with GS≥8(P<0.05). The expression of GTF2H4 and MNAT1 were relevant to the pathological stages(P<0.05). High expression of GTF2H4 has higher biochemical recurrence (BCR) rate in PCa patients(HR=2.47, 95%CI:1.62-3.77, P<0.001), which has better predictive effect of BCR in PCa patients(The 3rd, 5th, and 7th year AUC all>0.7) than other subunits, and it has been verified in four additional databases. Single-factor Cox regression analysis showed that GTF2H4 were risk factors for BCR (HR=2.470, 95%CI:1.620-3.767, P<0.001) and GTF2H5 were protective factors(HR=0.506,95%CI: 0.336-0.762, P=0.001). The results of immunohistochemical staining showed that the protein expression of GTF2H4 was correlated with the clinical features of PCa patients.The differences of the above results were statistically significant. Conclusion: GTF2H4, the key factor of TFIIH, is highly expressed in PCa and indicates a poor prognosis.
Collapse
|
2
|
[Clinicopathological features and prognosis of breast cancer with human epidermal growth factor receptor 2 low expression]. BEIJING DA XUE XUE BAO. YI XUE BAN = JOURNAL OF PEKING UNIVERSITY. HEALTH SCIENCES 2023; 55:243-253. [PMID: 37042134 PMCID: PMC10091245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 04/13/2023]
Abstract
OBJECTIVE There is an increasing interest in human epidermal growth factor receptor 2 (HER2) low expression breast cancer with the result of novel anti-HER2 antibody-drug conjugates for breast cancer. HER2 low expression breast cancer is expected to become a new type of breast cancer. This study analyzed and compared the clinicopathological features and survival data of breast cancer with HER2 low expression group [immunohistochemistry (IHC) 1+ or IHC 2+, and fluorescence in situ hybridization (FISH) negative] and HER2 zero expression group (IHC 0), in order to explore the difference in clinical biology of HER2 low expression breast cancers. METHODS Among 1 250 female patients with primary non-metastatic breast cancer admitted to the Breast Disease Center of Peking University First Hospital from January 2014 to December 2017, 969 cases were HER2 negative (IHC 0, 1+, 2+, and FISH was not amplified). The clinicopathologic features and prognosis of the patients with HER2 low expression (IHC 1+ or 2+, and unamplified by FISH) and HER2 zero expression (IHC 0) were analyzed. Disease free survival (DFS) and overall survival (OS) were evaluated, survival rates were calculated by Kaplan-Meier curve, and survival differences were compared by Log-rank test. Cox regression analysis of univariate and multivariate prognostic factors. Bilateral test was used, and P < 0.05 was considered statistically significant. RESULTS In the 969 patients with HER2 negative breast cancer, 606 had HER2 low expression (62.54%) and 363 had HER2 zero expression (37.46%). Compared with breast cancer with HER2 zero expression, those with HER2 low expression had higher N stage (P=0.001) and TNM stage (P=0.044), the proportion of non-specific histological types was higher (82.7% vs. 79.1%, P=0.009), the histological grade was higher (P=0.048), and the positive rate of hormone receptor was higher (83.2% vs. 75.2%, P=0.003). The percentage of Ki-67 value index >30% was lower (30.4% vs. 36.6%, P=0.044). There was no significant difference in DFS and OS between the two groups (P>0.05). In the 969 cases, 777 were hormone receptor positive and 192 were hormone receptor negative (triple negative cancer). Among the 777 cases with hormone receptor positive, 504 (64.9%) were HER2 low expression, and 273 (35.1%) were HER2 zero expression. Compared with breast cancer with HER2 zero expression group, the HER2 low expression group had a younger age (P=0.016), a higher proportion of premenopausal patients (P=0.029), more lymph node involvement (P=0.002), and a higher total TNM stage (P=0.031), and less frequent histological types of lobular and mucinous carcinoma (3.6% vs. 7.3%, 4.8% vs. 10.6%, P=0.001). There was no difference in DFS and OS between HER2 low expression and zero expression (P>0.05). Among 192 patients with hormone receptor negative, there were 102 cases (53.1%) with HER2 low expression and 90 cases (46.9%) with HER2 zero expression. Compared with the HER2 zero expression groups, HER2 low expression group was older (P=0.001), the proportion of premenopausal patients was low (P=0.029), the histological grade was lower (P < 0.001), the Ki-67 value index was lower (P < 0.001), and androgen receptor positive rate was higher (58.8% vs. 34.4%, P < 0.001). DFS was better than HER2 zero expression group (P=0.038), but there was no difference in OS between the two groups (P>0.05). CONCLUSION HER2 low expression breast cancer accounts for about half of all breast cancers, and the incidence is much higher than that of HER2 positive breast cancer. Its clinicopathologic features are heterogeneous, and the status of hormone receptor expression has an impact on the clinical biology of this group.
Collapse
|
3
|
[PD-1 inhibitor in chronic active Epstein-Barr virus infection: a report of six cases and literature review]. ZHONGHUA XUE YE XUE ZA ZHI = ZHONGHUA XUEYEXUE ZAZHI 2023; 44:165-168. [PMID: 36948875 PMCID: PMC10033261 DOI: 10.3760/cma.j.issn.0253-2727.2023.02.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Subscribe] [Scholar Register] [Indexed: 03/24/2023]
|
4
|
[Establishment and preliminary application of quantitative real-time PCR assay for the detection of SARS-CoV-2 subgenomic nucleocapsid RNA]. ZHONGHUA YU FANG YI XUE ZA ZHI [CHINESE JOURNAL OF PREVENTIVE MEDICINE] 2023; 57:268-272. [PMID: 36797587 DOI: 10.3760/cma.j.cn112150-20220407-00331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 02/18/2023]
Abstract
Objective: To establish a rapid and specific quantitative real-time PCR (qPCR) method for the detection of SARS-CoV-2 subgenomic nucleocapsid RNA (SgN) in patients with COVID-19 or environmental samples. Methods: The qPCR assay was established by designing specific primers and TaqMan probe based on the SARS-CoV-2 genomic sequence in Global Initiative of Sharing All Influenza Data (GISAID) database. The reaction conditions were optimized by using different annealing temperature, different primers and probe concentrations and the standard curve was established. Further, the specificity, sensitivity and repeatability were also assessed. The established SgN and genomic RNA (gRNA) qPCR assays were both applied to detect 21 environmental samples and 351 clinical samples containing 48 recovered patients. In the specimens with both positive gRNA and positive SgN, 25 specimens were inoculated on cells. Results: The primers and probes of SgN had good specificity for SARS-CoV-2. The minimum detection limit of the preliminarily established qPCR detection method for SgN was 1.5×102 copies/ml, with a coefficient of variation less than 1%. The positive rate of gRNA in 372 samples was 97.04% (361/372). The positive rates of SgN in positive environmental samples and positive clinical samples were 36.84% (7/19) and 49.42% (169/342), respectively. The positive rate and copy number of SgN in Wild strain were lower than those of SARS-CoV-2 Delta strain. Among the 25 SgN positive samples, 12 samples within 5 days of sampling time were all isolated with virus; 13 samples sampled for more than 12 days had no cytopathic effect. Conclusion: A qPCR method for the detection of SARS-CoV-2 SgN has been successfully established. The sensitivity, specificity and repeatability of this method are good.
Collapse
|
5
|
[Comparison of the efficacy and safety of 2 low-dose rituximab regimens in the second-line treatment of primary immune thrombocytopenia in children]. ZHONGHUA ER KE ZA ZHI = CHINESE JOURNAL OF PEDIATRICS 2022; 60:1185-1190. [PMID: 36319155 DOI: 10.3760/cma.j.cn112140-20220418-00340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Objective: To compare the efficacy and safety of 2 low-dose rituximab regimens in the treatment of children with primary immune thrombocytopenia (ITP). Methods: A total of 90 ITP children admitted to the Hematology Oncology Center of Beijing Children's Hospital from January 2018 to March 2021 were enrolled in this prospective cohort study. In the single-dose group, rituximab was given with a single dose of 375 mg/m2 (maximum dose 600 mg). In the 4-dose group, rituximab was given with a dose of 100 mg weekly (if body weight of the patient ≥ 30 kg, increase dosage to 200 mg weekly) for 4 weeks. Wilcoxon Mann-Whitney test, Chi-square test and Fisher's exact test were used to analyze the difference in efficacy, safety and treatment burden between two groups. Results: Among the 90 children, 41 were male and 49 were female, and the age of medication was 6.8 (4.1,10.0) years. There were 27 cases in the single-dose group and 63 cases in the 4-dose group.There were no significant differences in overall response rate, complete response rate and partial response rate between the single-dose group and 4-dose group (41% (11/27) vs. 33% (21/63), 26% (7/27) vs. 19% (12/63), 15% (4/27) vs. 14%(9/63), χ2=0.45, 0.54, 0.00, all P>0.05). The single-dose group was earlier to get overall response than the 4-dose group (1 (1, 1) vs. 3 (2, 6) weeks, Z=-3.24, P=0.001). There were no significant differences in the sustained response rate, the overall response rate in 1 year, the complete response rate in 1 year, and the partial response rate in 1 year between the single-dose group and the 4-dose group (33% (9/27) vs. 30% (19/63), 30% (8/27) vs. 24% (15/63), 19% (5/27) vs. 14% (9/63), 11% (3/27) vs. 10% (6/63), χ2=0.09, 0.34, 0.04, 0.00, all P>0.05). There were no significant differences in the duration of overall response, recurrence rate within half a year and one year, recurrence time and rate of adverse events between the single-dose group and 4-dose group (all P>0.05). The number of hospitalizations, the duration of hospital stays and the dosage of the single-dose group were significantly lower than those of the 4-dose group (1 (1, 1) vs. 4 (4, 4) times, 5 (4, 7) vs. 8 (5, 8) d, 400 (250, 500) vs. 400 (400, 800) mg, Z=-8.67, -3.03, -4.05, all P<0.05). Conclusions: The single-dose rituximab regimen is comparable to 4-dose rituximab regimen in effectiveness and safety for treatment of children ITP, but more economical and convenient. The single-dose rituximab regimen is more suitable for the second-line treatment of children ITP.
Collapse
|
6
|
Search for Subsolar-Mass Binaries in the First Half of Advanced LIGO's and Advanced Virgo's Third Observing Run. PHYSICAL REVIEW LETTERS 2022; 129:061104. [PMID: 36018635 DOI: 10.1103/physrevlett.129.061104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 03/18/2022] [Accepted: 06/07/2022] [Indexed: 06/15/2023]
Abstract
We report on a search for compact binary coalescences where at least one binary component has a mass between 0.2 M_{⊙} and 1.0 M_{⊙} in Advanced LIGO and Advanced Virgo data collected between 1 April 2019 1500 UTC and 1 October 2019 1500 UTC. We extend our previous analyses in two main ways: we include data from the Virgo detector and we allow for more unequal mass systems, with mass ratio q≥0.1. We do not report any gravitational-wave candidates. The most significant trigger has a false alarm rate of 0.14 yr^{-1}. This implies an upper limit on the merger rate of subsolar binaries in the range [220-24200] Gpc^{-3} yr^{-1}, depending on the chirp mass of the binary. We use this upper limit to derive astrophysical constraints on two phenomenological models that could produce subsolar-mass compact objects. One is an isotropic distribution of equal-mass primordial black holes. Using this model, we find that the fraction of dark matter in primordial black holes in the mass range 0.2 M_{⊙}<m_{PBH}<1.0 M_{⊙} is f_{PBH}≡Ω_{PBH}/Ω_{DM}≲6%. This improves existing constraints on primordial black hole abundance by a factor of ∼3. The other is a dissipative dark matter model, in which fermionic dark matter can collapse and form black holes. The upper limit on the fraction of dark matter black holes depends on the minimum mass of the black holes that can be formed: the most constraining result is obtained at M_{min}=1 M_{⊙}, where f_{DBH}≡Ω_{DBH}/Ω_{DM}≲0.003%. These are the first constraints placed on dissipative dark models by subsolar-mass analyses.
Collapse
|
7
|
[Perfect refractive cataract surgery: still a long way to go]. [ZHONGHUA YAN KE ZA ZHI] CHINESE JOURNAL OF OPHTHALMOLOGY 2022; 58:481-486. [PMID: 35796120 DOI: 10.3760/cma.j.cn112142-20220411-00172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Refractive cataract surgery has evolved considerably in recent years owing to the rapid development in precise ocular biometry, surgical technique and instrumentation, and various astigmatism-correcting and multifocal intraocular lenses. However, inherent defects of these premium intraocular lenses should not be underestimated and neither should imperfections of measuring devices. Cataract surgery complications such as posterior capsular opacification and dry eye, which were originally infrequent or minor, are becoming increasingly prominent. Surgeons must properly understand and conduct refractive cataract surgery and there is still a long way to go before perfection.
Collapse
|
8
|
[Comparison of tolerance to decentration and tilt in the early postoperative period between the continuous range and bifocal intraocular lens implantation in myopic eyes]. [ZHONGHUA YAN KE ZA ZHI] CHINESE JOURNAL OF OPHTHALMOLOGY 2022; 58:513-520. [PMID: 35796124 DOI: 10.3760/cma.j.cn112142-20220403-00154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Objective: To compare decentration and tilt tolerances between continuous range intraocular lens (IOL) and bifocal IOL in myopia during the early stages post intraocular implantation. Method: A retrospective cohort study was conducted using follow-up data of 145 patients (145 eyes) who underwent phacoemulsification combined with IOL implantation in the Eye & ENT Hospital of Fudan University from January 2018 to December 2020. According to whether the axial length was less than 24.5 mm, patients were divided into non-myopic and myopic groups. According to IOL type, patients were divided into extend depth of focus (EDOF) ZXR00 IOL group (myopic 38 eyes, non-myopic 41 eyes) and bifocal ZMB00 IOL group (myopic 23 eyes, non-myopic 43 eyes). The distance and near visual acuity (log of the minimum angle of resolution visual acuity), IOL tilt and decentration, intraocular high-order aberration (HOA), coma, trefoil, spherical aberrations, modulation transfer function (MTF), as well as VF-14 index and the incidence of dysphotopsia were compared between the 2 groups at 3 months after surgery. Statistics were performed using Student's t-test, χ2 test, Pearson correlation analysis and multiple linear regression analysis. Results: In either the myopic or non-myopic group, no significant differences were found in age, gender, eye laterality, axial length and IOL degree between eyes with the two different types of IOLs (all P>0.05). At 3 months after surgery, there was no significant difference in uncorrected and best-corrected distance visual acuity between the ZXR00 IOL group and the ZXR00 IOL group, while uncorrected near visual acuity was better in the ZMB00 IOL group than the ZXR00 IOL group (t=10.41, P<0.01). The total postoperative IOL decentration in the ZXR00 IOL group and ZMB00 IOL group in myopic eyes were (0.32±0.17) and (0.38±0.16) mm, respectively, which were greater than those in non-myopic eyes [(0.22±0.12), (0.28±0.12) mm; t=3.16, 2.57; both P<0.05]. However, there were no significant differences in IOL tilt between myopic and non-myopic eyes in the 2 groups (both P>0.05). There were no significant differences in postoperative IOL tilt and decentration between the 2 groups regardless of myopia or non-myopia (all P>0.05). In myopic eyes, HOA, coma aberration and spherical aberration in the ZXR00 IOL group were significantly lower than those in the ZMB00 IOL group, while the total ocular MTF (38.15±10.12) was significantly higher than that in the ZMB00 IOL group (30.46±10.53) (all P<0.05). Pearson correlation analysis and multiple linear regression analysis showed a positive correlation between postoperative HOA and both IOL tilt and decentration in the ZMB00 IOL group (r=0.627, 0.726; β=0.446, 0.587; all P<0.01). However, no such relationship was found in the ZXR00 IOL group (all P>0.05). In myopic eyes, when the IOL tilt aberration and decentration were greater than the median, the HOAs in the ZXR00 IOL group [(0.33±0.14), (0.27±0.11) μm] were lower than those in the ZMB00 IOL group [(0.88±0.56), (0.96±0.45) μm], while the total ocular MTF (42.87±10.97, 40.22±9.30) were higher than those in the ZMB00 IOL group (25.02±8.99, 29.87±10.19) (all P<0.05). In myopic eyes, the proportion of patients with visual interference symptoms in the ZXR00 IOL group [42.11% (16/38)] was significantly lower than that in the ZMB00 IOL group [78.26%(18/23), χ²=7.59, P<0.05]. Conclusion: During the early stages after IOL implantation in myopic eyes, EDOF IOL is more tolerant to decentration and tilt than bifocal IOL.
Collapse
|
9
|
[The influence of residual astigmatism on the postoperative visual quality in patients with implantation of an extended depth of focus intraocular lens]. [ZHONGHUA YAN KE ZA ZHI] CHINESE JOURNAL OF OPHTHALMOLOGY 2022; 58:334-339. [PMID: 35511659 DOI: 10.3760/cma.j.cn112142-20210918-00435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Objective: To investigate the influence of residual astigmatism on the postoperative visual acuity in cataract patients with implantation of an extended depth of focus intraocular lens (IOL). Methods: Retrospective cohort study. A total of 56 eyes of 56 cataract patients who underwent phacoemulsification combined with extended depth of focus IOL implantation from January 2019 to December 2020 at Eye & ENT Hospital of Fudan University were included. There were 29 males and 27 females in all patients, and the age was (65±9) years. Patients were divided into two groups according to their postoperative residual astigmatism: low astigmatism group (<0.75 D, 28 eyes) and high astigmatism group (0.75 to 1.50 D, 28 eyes). At 3 months after surgery, measurements were completed, including postoperative uncorrected distance (5 m) visual acuity, uncorrected intermediate (80 cm) visual acuity, uncorrected near (40 cm) visual acuity, best corrected visual acuity (all the visual acuity was converted to the logarithm of the minimum angle of resolution visual acuity), defocus curves, quick contrast sensitivity function, wavefront aberration, and VF-14 questionnaire scores. The independent samples t-test and Mann-Whitney U test were used for data analysis. Results: The low astigmatism group and high astigmatism group's uncorrected distance visual acuity [M (Q1, Q3)] were 0.05 (-0.06, 0.10), 0.08 (0.00, 0.22), their uncorrected intermediate visual acuity were 0.11 (0.00, 0.20), 0.14 (0.10, 0.21), their uncorrected near visual acuity were 0.28 (0.20, 0.32), 0.26 (0.20, 0.30), and their best corrected visual acuity were 0.17 (0.05, 0.30), 0.14 (0.04, 0.22), respectively. The differences were not statistically significant (all P>0.05). No significant difference was found in the defocus curves from +1.00 to -4.00 D, at intervals of +0.50 D, between the two groups (all P>0.05). No significant difference was found in the quick contrast sensitivity of low, middle and high frequency of dark vision between the low astigmatism group and high astigmatism group (all P>0.05), and the area under Log contrast sensitivity function of the two groups were 0.87±0.28 and 0.77±0.30 (P>0.05). The total whole-eye aberrations were 0.59±0.18 and 0.74±0.51, and the total higher-order aberrations were 0.30±0.13 and 0.37±0.25 in the two groups at 4.0-mm pupil diameter. The differences were not statistically significant when the total whole-eye aberration, total higher-order aberration, coma, cloverleaf aberration, and spherical aberration were compared (all P>0.05). The differences of the total VF-14 visual scores, near visual acuity scores and the distance visual acuity scores of the two groups were not statistically significant (all P>0.05). Conclusion: Cataract patients with residual postoperative astigmatism 0.75 to 1.50 D can obtain as good visual quality as those with postoperative residual astigmatism<0.75 D after implantation of an extended depth of focus IOL.
Collapse
|
10
|
[Comparative analysis of work-related musculoskeletal disorders catalogues]. ZHONGHUA LAO DONG WEI SHENG ZHI YE BING ZA ZHI = ZHONGHUA LAODONG WEISHENG ZHIYEBING ZAZHI = CHINESE JOURNAL OF INDUSTRIAL HYGIENE AND OCCUPATIONAL DISEASES 2022; 40:311-315. [PMID: 35545604 DOI: 10.3760/cma.j.cn121094-20210126-00054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Work-related musculoskeletal disorders (WMSDs) refer to musculoskeletal disorders caused by work or work as the main cause, which are characterized by high prevalence and heavy burden of disease as a global problem. The classification and catalog of occupational diseases is of great significance for guiding the prevention and control of occupational diseases and safeguarding the rights and interests of workers. The types of WMSDs included in the list of occupational diseases vary greatly from country to country, and the regulations on specific pathogenic factors are also inconsistent. By sorting out and analyzing the lists and characteristics of WMSDs at home and abroad, and using the International Statistical Classification of Diseases and Related Health Problems (ICD-10) in occupational health to standardize of WMSDs in various countries, which would lay the foundation for future multi-country WMSDs occupational health registration and disease burden research, and provide a reference for China to revise the WMSDs list.
Collapse
|
11
|
[Drought and Heat Stress-Mediated Modulation of Alternative Splicing in the Genes Involved in Biosynthesis of Metabolites Related to Tea Quality]. Mol Biol (Mosk) 2022; 56:321-322. [PMID: 35403623 DOI: 10.31857/s0026898422020057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2021] [Accepted: 07/31/2021] [Indexed: 06/14/2023]
Abstract
Alternative splicing (AS) regulates mRNAs at the post-transcriptional level to affect both their amounts and the protein function. However, little is known about the roles of AS in regulation of biosynthesis of amino acids, flavonoids, and volatile compounds in tea plants. In this study, we used Iso-seq and transcriptome deep sequencing (RNA-seq) to identify AS events, and analyzed the expression of respective mRNAs in tea plants under drought (DS), heat stress (HS), and their combination (HD). By RT-PCR, we validated the AS events in nine genes involved in the biosynthesis of amino acids and flavonoids. The genes accumulating AS transcripts under DS, HS, and HD conditions included those encoding for anthocyanidin reductase (ANR), dihydrofavonol-4-reductase-like (DFRA), and chalcone isomerase (CHI). Similarly, genes directly or indirectly involved in the biosynthesis of volatile compounds such as lipoxygenase (LOX), terpenoid/terpene synthase (TPS), and 1-deoxy-D-xylulose 5-phosphate reductoisomerase (DXR) also had AS events. Our study revealed that AS might specifically regulate the biosynthesis of amino acids in tea plants under stressful conditions. Moreover, we suggest that the AS events within the ANR and DFRA transcripts might play an important role in the regulation of flavonoid biosynthesis under DS, HS, and HD conditions. This study improved our understanding of the genetic drivers of the changes in the content of bioactive ingredients of tea plants subjected to abiotic stresses.
Collapse
|
12
|
[Relationship between pesticide exposure and lipid metabolism in population]. ZHONGHUA LAO DONG WEI SHENG ZHI YE BING ZA ZHI = ZHONGHUA LAODONG WEISHENG ZHIYEBING ZAZHI = CHINESE JOURNAL OF INDUSTRIAL HYGIENE AND OCCUPATIONAL DISEASES 2022; 40:24-27. [PMID: 35255557 DOI: 10.3760/cma.j.cn121094-20210126-00053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Objective: To investigate the effect of pesticides and herbicides on lipid metabolism. Methods: In November 2020, Based on the data of the national health and Nutrition Survey (NHANES) (2011-2014) , select the population aged 20~65 who have demographic information, pesticide use and data of four lipid metabolism indicators [total cholesterol (TC) , triglyceride (TG) , high density lipoprotein cholesterol (HDLC) and low density lipoprotein cholesterol (LDLC) ] (n=3039) . The subjects were divided into insecticide group (320 people) and non insecticide group (2719) according to the use of insecticides, and herbicide group (156 people) and non herbicide group according to the use of herbicides. Results: Among the 3039 subjects, the males and female were 1509 (49.7%) and 1530 (50.3%) respectively. The males age was (39.7±12.0) years and the females age was (40.2±12.0) years The concentration of HDLC in the NHANES (55.4±15.0) mg/dl was lower than that of (58.2±14.2) mg/dL in the non herbicide group (P<0.05) (b=-0.044, P<0.05) . The results showed that the use of herbicides was related to the decrease of HDLC and the increase of LDLC and LDLC/HDLC in female population (b=-0.050, 0.062, 0.067, all P<0.05) . Conclusion: Herbicide exposure can cause the change of lipid metabolism, and the effect on female population is more obvious.
Collapse
|
13
|
[Refractory ceramic fibers induced changes in serum Clara cell protein 16 and surfactant protein D levels in rats]. ZHONGHUA LAO DONG WEI SHENG ZHI YE BING ZA ZHI = ZHONGHUA LAODONG WEISHENG ZHIYEBING ZAZHI = CHINESE JOURNAL OF INDUSTRIAL HYGIENE AND OCCUPATIONAL DISEASES 2021; 39:887-892. [PMID: 35164415 DOI: 10.3760/cma.j.cn121094-20210506-00236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Objective: To explore the effect of refractory ceramic fibers (RCFs) on the serum Clara cell protein 16 (CC16) and surfactant protein D (SP-D) levels in Wistar rats. Methods: In October 2020, 96 healthy adult male Wistar rats were randomly divided into control group (equal volume of normal saline) , low-dose group (5 mg/ml RCFs) , medium-dose group (10 mg/ml RCFs) and high-dose group (20 mg/ml RCFs) , and subjected to non-exposure tracheal instillation. After intraperitoneal anesthesia, the rats were instilled with 200 μl of RCFs suspension or normal saline, once every 3 days for a total of 4 times. At 7, 14, 28, and 90 days after exposure, 6 rats were sacrificed by blood sampling through the abdominal aorta. The organs were separated, histopathological changes of lungs were observed and lung injury scores were performed. The contents of serum CC16 and SP-D were determined by enzyme-linked immunosorbent assay (ELISA) . Results: RCFs could cause inflammatory cells in rat lung tissues, widening of the lung septum and destruction of alveolar structure. 7 days after exposure, the lung injury scores of rats in each dose group were higher than control group, and the lung injury score of the high-dose group was higher than low-dose group (P<0.05) . 14 and 90 days after exposure, the lung injury scores of the medium-dose and high-dose groups were higher than control group (P<0.05) . 28 days after exposure, the lung injury score of the high-dose group was higher than control group (P<0.05) . 7 days after exposure, the serum CC16 and SP-D concentrations of rats in the medium-dose and high-dose groups were significantly higher than control and low-dose groups (P<0.05) . 28 days after exposure, the serum CC16 concentrations of rats in the low-dose and medium-dose groups were significantly lower than those of the control and high-dose groups (P<0.05) . After 90 days of exposure, the serum CC16 concentrations of rats decreased with the increase of the exposure dose (F=28.853, P<0.01) , and the concentrations of SP-D increased with the increase of the exposure dose (F=25.636, P<0.01) . Conclusion: RCFs exposure may cause certain damage to rat Clara cells and alveolar-capillary barrier. The severity of lung injury can be indirectly understood through the dynamic changes of serum CC16 and SP-D.
Collapse
|
14
|
[A case of oculocutaneous albinism with cataract]. [ZHONGHUA YAN KE ZA ZHI] CHINESE JOURNAL OF OPHTHALMOLOGY 2021; 57:787-790. [PMID: 34619951 DOI: 10.3760/cma.j.cn112142-20210518-00235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
A female patient with totally white hair and pink skin had gradual visual loss to hand motion in the right eye within one year. Upon her visit to the Department of Ophthalmology, she was found to have a totally white cataract and a family history of intermarriage, and was finally diagnosed with oculocutaneous albinism and complicated cataract in the right eye. The best corrected visual acuity of her right eye increased to 0.15 at 6 months after phacoemulsification and intraocular lens implantation. Clear choroidal vessels could be seen in the ultra-widefield color fundus image and autofluorescence image. No macular fovea structure was found on optical coherence tomography of the fundus. (Chin J Ophthalmol, 2021, 57: 787-790).
Collapse
|
15
|
Constraints on Cosmic Strings Using Data from the Third Advanced LIGO-Virgo Observing Run. PHYSICAL REVIEW LETTERS 2021; 126:241102. [PMID: 34213926 DOI: 10.1103/physrevd.97.102002] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 03/31/2021] [Accepted: 05/23/2021] [Indexed: 05/21/2023]
Abstract
We search for gravitational-wave signals produced by cosmic strings in the Advanced LIGO and Virgo full O3 dataset. Search results are presented for gravitational waves produced by cosmic string loop features such as cusps, kinks, and, for the first time, kink-kink collisions. A template-based search for short-duration transient signals does not yield a detection. We also use the stochastic gravitational-wave background energy density upper limits derived from the O3 data to constrain the cosmic string tension Gμ as a function of the number of kinks, or the number of cusps, for two cosmic string loop distribution models. Additionally, we develop and test a third model that interpolates between these two models. Our results improve upon the previous LIGO-Virgo constraints on Gμ by 1 to 2 orders of magnitude depending on the model that is tested. In particular, for the one-loop distribution model, we set the most competitive constraints to date: Gμ≲4×10^{-15}. In the case of cosmic strings formed at the end of inflation in the context of grand unified theories, these results challenge simple inflationary models.
Collapse
|
16
|
Constraints on Cosmic Strings Using Data from the Third Advanced LIGO-Virgo Observing Run. PHYSICAL REVIEW LETTERS 2021; 126:241102. [PMID: 34213926 DOI: 10.1103/physrevlett.126.241102] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 03/31/2021] [Accepted: 05/23/2021] [Indexed: 06/13/2023]
Abstract
We search for gravitational-wave signals produced by cosmic strings in the Advanced LIGO and Virgo full O3 dataset. Search results are presented for gravitational waves produced by cosmic string loop features such as cusps, kinks, and, for the first time, kink-kink collisions. A template-based search for short-duration transient signals does not yield a detection. We also use the stochastic gravitational-wave background energy density upper limits derived from the O3 data to constrain the cosmic string tension Gμ as a function of the number of kinks, or the number of cusps, for two cosmic string loop distribution models. Additionally, we develop and test a third model that interpolates between these two models. Our results improve upon the previous LIGO-Virgo constraints on Gμ by 1 to 2 orders of magnitude depending on the model that is tested. In particular, for the one-loop distribution model, we set the most competitive constraints to date: Gμ≲4×10^{-15}. In the case of cosmic strings formed at the end of inflation in the context of grand unified theories, these results challenge simple inflationary models.
Collapse
|
17
|
[Minutes of the 2020 China Rhinology Annual Meeting]. ZHONGHUA ER BI YAN HOU TOU JING WAI KE ZA ZHI = CHINESE JOURNAL OF OTORHINOLARYNGOLOGY HEAD AND NECK SURGERY 2021; 56:548-552. [PMID: 34011018 DOI: 10.3760/cma.j.cn115330-20210224-00085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
18
|
Identification of hub genes and pathways in the development of gastric cancer by gene co‑expression network analysis. J BIOL REG HOMEOS AG 2021; 35:35-44. [PMID: 33601878 DOI: 10.23812/20-478-a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
There are many risk factors for gastric cancer (GC), including chronic atrophic gastritis, which involves multiple genes and signaling pathways. Weighted gene co-expression network analysis (WGCNA) was performed on GSE111762 to construct free-scale gene co-expression networks and identified four significant modules that consisted of blue, dark orange, dark red and dark violet. In each module, genes with the most connectivity were selected as hub genes, including G antigen 12J (GAGE12J) in blue, proline, histidine and glycine rich 1 (PHGR1) in dark orange, DNA polymerase gamma 2, accessory subunit (POLG2) in dark red and collagen type XXI alpha 1 chain (COL21A1) in dark violet. The transcription level of COL21A1 and GAGE12J was up-regulated in atrophic gastritis vs normal gastric mucosa, but down-regulated in GC vs atrophic gastritis. PHGR1 was consistently down-regulated from normal gastric mucosa to GC, while POLG2 was up-regulated. Gene set enrichment analysis (GSEA) was then conducted to study the biological functions of hub genes in the development of GC. It showed that multiple tumorigenesis-related pathways were enriched, including peroxisome, DNA repair and KRAS signaling pathway in COL21A1, IL6-JAK-STAT3, epithelial mesenchymal transition (EMT) and TNFα-NF-κB signaling pathway in PHGR1, MYC targets, E2F targets and angiogenesis in POLG2 and peroxisome, Notch signaling pathway and androgen response in GAGE12J. The identified four genes, especially for COL21A1, PHGR1 and POLG2, were important in GC tumorigenesis and affected many cancer-related pathways.
Collapse
|
19
|
GW190521: A Binary Black Hole Merger with a Total Mass of 150 M_{⊙}. PHYSICAL REVIEW LETTERS 2020; 125:101102. [PMID: 32955328 DOI: 10.1103/physrevlett.125.101102] [Citation(s) in RCA: 73] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Revised: 06/19/2020] [Accepted: 07/09/2020] [Indexed: 06/08/2023]
Abstract
On May 21, 2019 at 03:02:29 UTC Advanced LIGO and Advanced Virgo observed a short duration gravitational-wave signal, GW190521, with a three-detector network signal-to-noise ratio of 14.7, and an estimated false-alarm rate of 1 in 4900 yr using a search sensitive to generic transients. If GW190521 is from a quasicircular binary inspiral, then the detected signal is consistent with the merger of two black holes with masses of 85_{-14}^{+21} M_{⊙} and 66_{-18}^{+17} M_{⊙} (90% credible intervals). We infer that the primary black hole mass lies within the gap produced by (pulsational) pair-instability supernova processes, with only a 0.32% probability of being below 65 M_{⊙}. We calculate the mass of the remnant to be 142_{-16}^{+28} M_{⊙}, which can be considered an intermediate mass black hole (IMBH). The luminosity distance of the source is 5.3_{-2.6}^{+2.4} Gpc, corresponding to a redshift of 0.82_{-0.34}^{+0.28}. The inferred rate of mergers similar to GW190521 is 0.13_{-0.11}^{+0.30} Gpc^{-3} yr^{-1}.
Collapse
|
20
|
Application of multidirectional stitching technology in a laparoscopic suturing instructional program: a randomized controlled trial. BMC MEDICAL EDUCATION 2020; 20:248. [PMID: 32753043 PMCID: PMC7409432 DOI: 10.1186/s12909-020-02146-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Accepted: 07/09/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND Surgeon suturing technology plays a pivotal role in patient recovery after laparoscopic surgery. Intracorporal suturing and knot tying in minimally invasive surgery are particularly challenging and represent a key skill for advanced procedures. In this study, we compared the application of multidirectional stitching technology with application of the traditional method in a laparoscopic suturing instructional program. METHODS We selected forty residents within two years of graduation to assess the specialized teaching of laparoscopic suturing with laparoscopic simulators. The forty students were randomly divided into two groups, a control group and an experimental group, with twenty students in each group. The control group was scheduled to learn the traditional suture method, and the experimental group applied multidirectional stitching technology. The grades for suturing time, thread length, accuracy of needle entry, stability of the knot, tissue integrity, and tightness of the tissue before and after the training program were calculated. RESULTS There was no significant difference between the two groups before the learning intervention. After the program, both groups significantly improved in each subject. There were significant differences between the control group and the experimental group in suture time (P = 0.001), accuracy of needle entry and exit (P = 0.035), and whether the suture tissue had cracks (P = 0.030). However, the two groups showed non-significant differences in thread length (P = 0.093), stablity of the knot (P = 0.241), or tightness of the tissue (P = 0.367). CONCLUSIONS Multidirectional stitching technology improves the efficiency and effectiveness of traditional laparoscopic suture instructional programs. It might be a practicable, novel training method for acquiring proficiency in manual laparoscopic skills in a training setting.
Collapse
|
21
|
Unmedicated patients with schizophrenia in economically underdeveloped areas of China. Asian J Psychiatr 2020; 47:101865. [PMID: 31743835 DOI: 10.1016/j.ajp.2019.101865] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Revised: 11/01/2019] [Accepted: 11/01/2019] [Indexed: 12/22/2022]
Abstract
OBJECTIVES Untreated schizophrenia commonly leads to poor prognosis. The medication treatment rate of schizophrenia patients in economically underdeveloped areas of China has not been well-studied. This study aimed to examine the pattern of unmedicated schizophrenia patients in economically underdeveloped rural and urban areas of China. METHOD A total of 4240 schizophrenia patients in Lanzhou (1720 rural and 2520 urban patients) registered in the community mental-health service system in Lanzhou, Gansu province were included. Their socio-demographic and clinical characteristics including medication treatment status were collected and analyzed. RESULTS The proportion of unmedicated schizophrenia patients was 22.5% (n = 953) in the whole sample, with 32.3% (556/1720) in rural and 15.8% (397/2520) in urban patients (X2=161.1, P < 0.001). Multiple logistic regression analyses revealed that unmedicated schizophrenia patients in rural area were more likely to be older (OR=1.02, 95%CI: 1.01-1.03), male (OR=1.35, 95%CI: 1.07-1.71), unmarried (OR=0.71, 95%CI: 0.55-0.91), and have lower educational level (OR=0.39, 95%CI: 0.24-0.65), longer illness duration (OR=1.01, 95%CI: 1.00-1.02) and less frequent admissions (OR=0.46, 95%CI: 0.38-0.54). In contrast, unmedicated patients in urban area were more likely to be older (OR=1.01, 95%CI: 1.00-1.02), unmarried (OR=0.77, 95%CI: 0.61-0.98), employed (OR=2.38, 95%CI: 1.87-3.04), and have lower educational level (OR=0.49, 95%CI: 0.37-0.65), better financial status (OR=0.60, 95%CI: 0.48-0.76) and less frequent admissions (OR=0.81, 95%CI: 0.75-0.87). CONCLUSIONS The rate of unmedicated schizophrenia patients is high in economically underdeveloped areas of China, particularly in rural areas. Effective policies and measures should be implemented urgently to improve the treatment rate in this population.
Collapse
|
22
|
Search for Subsolar Mass Ultracompact Binaries in Advanced LIGO's Second Observing Run. PHYSICAL REVIEW LETTERS 2019; 123:161102. [PMID: 31702344 DOI: 10.1103/physrevlett.123.161102] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2019] [Indexed: 06/10/2023]
Abstract
We present a search for subsolar mass ultracompact objects in data obtained during Advanced LIGO's second observing run. In contrast to a previous search of Advanced LIGO data from the first observing run, this search includes the effects of component spin on the gravitational waveform. We identify no viable gravitational-wave candidates consistent with subsolar mass ultracompact binaries with at least one component between 0.2 M_{⊙}-1.0 M_{⊙}. We use the null result to constrain the binary merger rate of (0.2 M_{⊙}, 0.2 M_{⊙}) binaries to be less than 3.7×10^{5} Gpc^{-3} yr^{-1} and the binary merger rate of (1.0 M_{⊙}, 1.0 M_{⊙}) binaries to be less than 5.2×10^{3} Gpc^{-3} yr^{-1}. Subsolar mass ultracompact objects are not expected to form via known stellar evolution channels, though it has been suggested that primordial density fluctuations or particle dark matter with cooling mechanisms and/or nuclear interactions could form black holes with subsolar masses. Assuming a particular primordial black hole (PBH) formation model, we constrain a population of merging 0.2 M_{⊙} black holes to account for less than 16% of the dark matter density and a population of merging 1.0 M_{⊙} black holes to account for less than 2% of the dark matter density. We discuss how constraints on the merger rate and dark matter fraction may be extended to arbitrary black hole population models that predict subsolar mass binaries.
Collapse
|
23
|
Tests of General Relativity with GW170817. PHYSICAL REVIEW LETTERS 2019; 123:011102. [PMID: 31386391 DOI: 10.1103/physrevlett.123.011102] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2018] [Revised: 03/21/2019] [Indexed: 06/10/2023]
Abstract
The recent discovery by Advanced LIGO and Advanced Virgo of a gravitational wave signal from a binary neutron star inspiral has enabled tests of general relativity (GR) with this new type of source. This source, for the first time, permits tests of strong-field dynamics of compact binaries in the presence of matter. In this Letter, we place constraints on the dipole radiation and possible deviations from GR in the post-Newtonian coefficients that govern the inspiral regime. Bounds on modified dispersion of gravitational waves are obtained; in combination with information from the observed electromagnetic counterpart we can also constrain effects due to large extra dimensions. Finally, the polarization content of the gravitational wave signal is studied. The results of all tests performed here show good agreement with GR.
Collapse
|
24
|
Abstract
The purpose of this study was to evaluate the application of multimodal intraoperative monitoring (MIOM) system in patients with congenital scoliosis (CS) and adolescent idiopathic scoliosis (AIS).Twelve patients who underwent posterior surgical correction of scoliosis for CS and AIS from June 2014 to July 2018 were enrolled in this study. During the operation, we monitored the functional status of the spinal cord by MIOM. An abnormal somatosensory evoked potential was defined as a prolonged latency of more than 10% or a peak-to-peak amplitude decline of more than 50% when compared to baseline. An abnormal transcranial motor evoked potential (TcMEP) was defined as a TcMEP amplitude decrease of more than 50%. A normal triggered electromyography response, which presented with the absence of an electrical response on stimulation at 8.2 mA, indicated that the pedicle screw was not in contact with the spinal cord or nerve root.A total of 12 patients underwent MIOM surgery, of which 9 patients with negative MIOM had no significant deterioration of neurological function postoperatively, and exhibited satisfactory surgical correction of scoliosis during follow-ups. However, the remaining 3 patients suffered from MIOM events, 2 patients had normal neurological function, and 1 patient had deteriorated neurological function postoperatively.Using MIOM in CS and AIS surgery could promptly detect iatrogenic neurological injury at the early stage. Therefore, rapid response by appropriate intraoperative interventions can be taken to minimize the injury. Besides, stable MIOM recordings encourage surgeons to correct scoliosis even when the Cobb angle of scoliosis was extremely large.
Collapse
|
25
|
Abstract
The Wnt ligands display varied spatiotemporal expression in the epithelium and mesenchyme in the developing tooth. Thus far, the actions of these differentially expressed Wnt ligands on tooth development are not clear. Shh expression specifies the odontogenic epithelium during initiation and is consistently restricted to the dental epithelium during tooth development. In this study, we inactivate Wntless ( Wls), the key regulator for Wnt trafficking, by Shh-Cre to investigate how the Wnt ligands produced in the dental epithelium lineage act on tooth development. We find that conditional knockout of Wls by Shh-Cre leads to defective ameloblast and odontoblast differentiation. WlsShh-Cre teeth display reduced canonical Wnt signaling activity in the inner enamel epithelium and the underlying mesenchyme at the early bell stage, as exhibited by target gene expression and BAT-gal staining. The expression of Wnt5a and Wnt10b is not changed in WlsShh-Cre teeth. By contrast, Wnt10a expression is significantly increased in response to epithelial Wls deficiency. In addition, the expression of Hedgehog signaling pathway components Shh, Gli1, and Patched1 was greatly decreased in WlsShh-Cre teeth. Epithelial Wls loss of function in Shh lineage also leads to aberrant cell proliferation in dental epithelium and mesenchyme at embryonic day 16.5; however, the cell apoptosis is unaffected. Moreover, we find that Decorin and Col1a1, the key markers for odontoblast differentiation that are downregulated in WlsShh-Cre teeth, act as direct downstream targets of the canonical Wnt signaling pathway by chromatin immunoprecipitation analysis. Additionally, Decorin and Col1a1 expression can be increased by lithium chloride (LiCl) treatment in the in vitro tooth explants. Taken together, our results suggest that the spatial expression of Wnt ligands within the dental epithelial lineage regulates the differentiation of tooth structures in later stages.
Collapse
|
26
|
[Analysis of occupational poisoning in Jiangsu Province, from 2006-2015]. ZHONGHUA LAO DONG WEI SHENG ZHI YE BING ZA ZHI = ZHONGHUA LAODONG WEISHENG ZHIYEBING ZAZHI = CHINESE JOURNAL OF INDUSTRIAL HYGIENE AND OCCUPATIONAL DISEASES 2019; 36:622-625. [PMID: 30317816 DOI: 10.3760/cma.j.issn.1001-9391.2018.08.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: Analysis of occupational poisoning character and laws in Jiangsu Province from 2006-2015, so as to provide scientific basis for the formulation of effective intervention measures and prevention strategies. Methods: According to the data of Jiangsu province occupational poisoning cases reports of year 2006 to 2015, by EXCEL arranged, using SPSS software to do epidemiological data statistical analysis. Results: In the past ten years, the number of occupational poisoning cases reported in Jiangsu province increased first and then declined. 547 cases of acute occupational poisoning reported in Jiangsu province from 2006-2015 years (35.82% of the total poisoning cases, the same below) , 980 cases of chronic occupational poisoning (64.18%) . The ratio of male and female in acute poisoning was 2.48, while 1.55 of chronic poisoning. The cases of poisoning reported were young and middle-aged, and working years was mainly in 5 years. The cases reported in the south of Jiangsu (mainly is chronic poisoning) is higher than that in the northern part of Jiangsu (mainly is acute poisoning) , which is more economically underdeveloped.. The reported highest mortality rate of occupational poisoning is asphyxia gas poisoning (5.43%) , followed by irritating gas poisoning (2.99%) and organic solvent poisoning (0.47%) . Many more occupational poisoning cases reported from large, joint-stock enterprises, especially chronic poisoning. Meanwhile more cases of acute poisoning reported from small, micro private enterprises. Conclusion: Although a decline in occupational poisoning cases in Jiangsu, the prevention and treatment measures are still not lax. According to the species of toxic, regional economic differences, the scale of the enterprises and the type of economy, the characteristic key classification and prevention should be carried out. Expand the coverage of hospitals in the diagnosis and reporting of occupational poisoning diseases, and strive to improve the quality of occupational disease reports.
Collapse
|
27
|
[Analysis on the relationship between Occupational Stress Factors and Psychological Stress Reaction among Petrochemical Workers]. ZHONGHUA LAO DONG WEI SHENG ZHI YE BING ZA ZHI = ZHONGHUA LAODONG WEISHENG ZHIYEBING ZAZHI = CHINESE JOURNAL OF INDUSTRIAL HYGIENE AND OCCUPATIONAL DISEASES 2019; 36:863-867. [PMID: 30646657 DOI: 10.3760/cma.j.issn.1001-9391.2018.11.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: Analyze the detection rates of occupational contraindication and suspected occupational disease from the employee exposure to noise and describe the distribution characteristics. Methods: According to the Technical Specifications for Occupational Health Surveillance (GBZ 188-2014) 、Diagnosis of Occupational Noise-induced Deafness (GBZ 49-2014) and Guideline of Identification of Contraindication to Job Placement (GBZ/T 260-2014) , calculate and analyze the occupational contraindication and suspected occupational disease detection rates of 149 271 workers from January 1st to December 31st in 2015 who were exposed to noise. Analyze the detection rates distribution characteristics between different gender, age, seniority, industry and enterprise scale. Results: The detection rates of occupational contraindication is 2.08%. The suspected occupational disease detection rates of absences workers (2.13%) is higher than during (2.03%) . The occupational contraindication detection rates of< age 20 (2.64%) , 41~50 years old (2.48%) and<1 working years (5.35%) , are higher than others. The detection rates of suspected occupational disease increases with the growth of ages and working years. The occupational contraindication detection rates of scientific research and technology services industry (10.46%) is the highest. The suspected occupational disease detection rates of transportation warehousing and postal services (5.88%) is the highest. The occupational contraindication detection rates of medium-sized enterprise (2.27%) is the highest, meanwhile, the microenterprise's (1.60%) is the lowest. The suspected occupational disease detection rates of large-scale enterprise (3.21%) is the highest, meanwhile, the microenterprise's (1.33%) is the lowest. Conclusion: Enterprise should insist on regular occupational health examination, strengthen screening of occupational contraindication in new workers, especially pre-job workers and detect the occupational disease patients early. Focus on non-traditional noise industries above mentioned, improve intensity of noise hazards prevention and control. The detection rates of occupational contraindication and suspected occupational disease can be used as a reference standard for the quality control of occupational examination and report of medical institutions.
Collapse
|
28
|
[Tyrosine kinase inhibitors discontinuation for chronic myeloid leukemia: a multicenter retrospective analysis in China]. ZHONGHUA XUE YE XUE ZA ZHI = ZHONGHUA XUEYEXUE ZAZHI 2019; 39:994-997. [PMID: 30612400 PMCID: PMC7348222 DOI: 10.3760/cma.j.issn.0253-2727.2018.12.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
目的 回顾性分析中国慢性髓性白血病(CML)酪氨酸激酶抑制剂(TKI)自动停药患者的临床特征及转归情况。 方法 回顾性分析2005年6月1日至2018年3月1日国内7家单位109例自动停用TKI的慢性期CML患者临床资料,将其中具有明确停药结局及相对完整临床资料的91例患者进行统计分析,观察患者自动停药后获得无治疗缓解(TFR)情况及其影响因素。 结果 91例患者累积服用TKI中位时间为65(7~138)个月,其中21例患者有减停药史;患者达到主要分子学缓解(MMR)中位时间为开始服用TKI后6(3~57)个月;全部患者停药前达MR4.0。停药后中位随访9(1~72)个月,53例(58.2%)患者继续维持MMR,获得TFR;38例(41.8%)失去MMR。12个月和25个月的TFR率分别为61.4%和52.6%。31例停药后复发的患者再启动药物治疗,用药后再获得MMR的中位时间为3(1~12)个月。对比分析发现,Sokal评分(P=0.294)、累积服用TKI时间(P=0.827)、获得MMR所需时间(P=0.553),是否减停TKI(P=0.125)等因素对复发无明显影响。而停药前MMR维持时间越长(≥24个月)患者后期复发率越低(P=0.027)。 结论 达停药标准的中国CML患者能够安全停用TKI,停药后TFR率与国外报道相当。停药前MMR时间维持越长,停药后复发率越低。
Collapse
|
29
|
Constraining the p-Mode-g-Mode Tidal Instability with GW170817. PHYSICAL REVIEW LETTERS 2019; 122:061104. [PMID: 30822067 DOI: 10.1103/physrevlett.122.061104] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Revised: 10/30/2018] [Indexed: 06/09/2023]
Abstract
We analyze the impact of a proposed tidal instability coupling p modes and g modes within neutron stars on GW170817. This nonresonant instability transfers energy from the orbit of the binary to internal modes of the stars, accelerating the gravitational-wave driven inspiral. We model the impact of this instability on the phasing of the gravitational wave signal using three parameters per star: an overall amplitude, a saturation frequency, and a spectral index. Incorporating these additional parameters, we compute the Bayes factor (lnB_{!pg}^{pg}) comparing our p-g model to a standard one. We find that the observed signal is consistent with waveform models that neglect p-g effects, with lnB_{!pg}^{pg}=0.03_{-0.58}^{+0.70} (maximum a posteriori and 90% credible region). By injecting simulated signals that do not include p-g effects and recovering them with the p-g model, we show that there is a ≃50% probability of obtaining similar lnB_{!pg}^{pg} even when p-g effects are absent. We find that the p-g amplitude for 1.4 M_{⊙} neutron stars is constrained to less than a few tenths of the theoretical maximum, with maxima a posteriori near one-tenth this maximum and p-g saturation frequency ∼70 Hz. This suggests that there are less than a few hundred excited modes, assuming they all saturate by wave breaking. For comparison, theoretical upper bounds suggest ≲10^{3} modes saturate by wave breaking. Thus, the measured constraints only rule out extreme values of the p-g parameters. They also imply that the instability dissipates ≲10^{51} erg over the entire inspiral, i.e., less than a few percent of the energy radiated as gravitational waves.
Collapse
|
30
|
Search for Subsolar-Mass Ultracompact Binaries in Advanced LIGO's First Observing Run. PHYSICAL REVIEW LETTERS 2018; 121:231103. [PMID: 30576173 DOI: 10.1103/physrevlett.121.231103] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2018] [Indexed: 05/21/2023]
Abstract
We present the first Advanced LIGO and Advanced Virgo search for ultracompact binary systems with component masses between 0.2 M_{⊙}-1.0 M_{⊙} using data taken between September 12, 2015 and January 19, 2016. We find no viable gravitational wave candidates. Our null result constrains the coalescence rate of monochromatic (delta function) distributions of nonspinning (0.2 M_{⊙}, 0.2 M_{⊙}) ultracompact binaries to be less than 1.0×10^{6} Gpc^{-3} yr^{-1} and the coalescence rate of a similar distribution of (1.0 M_{⊙}, 1.0 M_{⊙}) ultracompact binaries to be less than 1.9×10^{4} Gpc^{-3} yr^{-1} (at 90% confidence). Neither black holes nor neutron stars are expected to form below ∼1 M_{⊙} through conventional stellar evolution, though it has been proposed that similarly low mass black holes could be formed primordially through density fluctuations in the early Universe and contribute to the dark matter density. The interpretation of our constraints in the primordial black hole dark matter paradigm is highly model dependent; however, under a particular primordial black hole binary formation scenario we constrain monochromatic primordial black hole populations of 0.2 M_{⊙} to be less than 33% of the total dark matter density and monochromatic populations of 1.0 M_{⊙} to be less than 5% of the dark matter density. The latter strengthens the presently placed bounds from microlensing surveys of massive compact halo objects (MACHOs) provided by the MACHO and EROS Collaborations.
Collapse
|
31
|
Accuracy and safety of percutaneous periacetabular screw insertion using screw view model of navigation in acetabular fracture: A case report. Medicine (Baltimore) 2018; 97:e13316. [PMID: 30544391 PMCID: PMC6310583 DOI: 10.1097/md.0000000000013316] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
RATIONALE The purpose of this study was to estimate the efficacy and safety of percutaneous periacetabular screw (PPS) insertion assisted by screw view model of navigation (SVMN) to treat fracture of acetabulum. PATIENT CONCERNS A 61-year-old male patient was injured in a motorcycle accident, which caused pain, swelling, deformity and limited mobility on his right hip. DIAGNOSES He was diagnosed with fracture of acetabulum. INTERVENTIONS We used PPS insertion assisted by SVMN to treat fracture of acetabulum in this patient. OUTCOMES The follow up lasted 24 months. Totally 2 screws were inserted into anterior and posterior column of acetabulum respectively and both of them displayed grade 0. Compared with the preoperative gap and step of fracture displacement, the postoperative ones were significantly reduced. It took 11.7 minutes for designing the screws, 6.7 minutes for implanting the guide wire, and 45.5 minutes for placing the screws. Intraoperative blood loss was 29 mL and total fluoroscopic time was 4.1 minutes. No clinical complications such as nerve vascular injury, infection and screw loosening were found after the operation. LESSONS The study indicated that SVMN is favorable to the PPS insertion for acetabular fracture. Our lesson is that the relative position between the acetabular and the patient tracker must be static to ensure the accuracy of the entire system throughout the operation.
Collapse
|
32
|
A screw-view model of navigation aid retrograde transpubic screw fixation for anterior pelvic ring fracture: A case report with 28 months follow-up and technical note. Medicine (Baltimore) 2018; 97:e13646. [PMID: 30572479 PMCID: PMC6320056 DOI: 10.1097/md.0000000000013646] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
Abstract
RATIONALE The purpose of this study was to evaluate the accuracy of a retrograde transpubic screw fixation assisted by a screw-view model of navigation in treating a pelvic fracture. PATIENT CONCERNS A 30-year-old female patient injured in a motor vehicle accident, displayed symptoms characterized by swelling and pain of the pudendum. DIAGNOSES The patient was diagnosed with a fracture of the pubic ramus. INTERVENTIONS We used a screw-view model of navigation to assist our retrograde transpubic screw fixation in this patient. OUTCOMES In total, 2 screws were inserted into the bilateral pubic ramus and both were excellently positioned. It took 7.4 minutes to design the screws, 8.1 minutes to implant the guidewire, and 39.3 minutes to place the screws. Intraoperative blood loss amounted to 21 mL and the total fluoroscopic time was 3.8 minutes. No clinical complications, such as neurologic, vascular, or urologic injury, infection, screw loosening, or loss of reduction, were found after the operation. Follow-up lasted 28 months. LESSONS The outcome of our study suggests that the screw-view model of navigation maximizes the retrograde transpubic screw insertion accuracy in the treatment of a pubic ramus fracture, which is made efficient by pain relief and early out-of-bed mobilization. Our suggestion is, therefore, that the relative position between the pubic ramus and the patient tracker must be static to ensure the accuracy of the entire system throughout the operation.
Collapse
|
33
|
GW170817: Measurements of Neutron Star Radii and Equation of State. PHYSICAL REVIEW LETTERS 2018; 121:161101. [PMID: 30387654 DOI: 10.1103/physrevlett.121.161101] [Citation(s) in RCA: 186] [Impact Index Per Article: 31.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Revised: 07/25/2018] [Indexed: 06/08/2023]
Abstract
On 17 August 2017, the LIGO and Virgo observatories made the first direct detection of gravitational waves from the coalescence of a neutron star binary system. The detection of this gravitational-wave signal, GW170817, offers a novel opportunity to directly probe the properties of matter at the extreme conditions found in the interior of these stars. The initial, minimal-assumption analysis of the LIGO and Virgo data placed constraints on the tidal effects of the coalescing bodies, which were then translated to constraints on neutron star radii. Here, we expand upon previous analyses by working under the hypothesis that both bodies were neutron stars that are described by the same equation of state and have spins within the range observed in Galactic binary neutron stars. Our analysis employs two methods: the use of equation-of-state-insensitive relations between various macroscopic properties of the neutron stars and the use of an efficient parametrization of the defining function p(ρ) of the equation of state itself. From the LIGO and Virgo data alone and the first method, we measure the two neutron star radii as R_{1}=10.8_{-1.7}^{+2.0} km for the heavier star and R_{2}=10.7_{-1.5}^{+2.1} km for the lighter star at the 90% credible level. If we additionally require that the equation of state supports neutron stars with masses larger than 1.97 M_{⊙} as required from electromagnetic observations and employ the equation-of-state parametrization, we further constrain R_{1}=11.9_{-1.4}^{+1.4} km and R_{2}=11.9_{-1.4}^{+1.4} km at the 90% credible level. Finally, we obtain constraints on p(ρ) at supranuclear densities, with pressure at twice nuclear saturation density measured at 3.5_{-1.7}^{+2.7}×10^{34} dyn cm^{-2} at the 90% level.
Collapse
|
34
|
DS1/OsEMF1 interacts with OsARF11 to control rice architecture by regulation of brassinosteroid signaling. RICE (NEW YORK, N.Y.) 2018; 11:46. [PMID: 30084027 PMCID: PMC6082143 DOI: 10.1186/s12284-018-0239-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Accepted: 07/27/2018] [Indexed: 05/05/2023]
Abstract
BACKGROUND Plant height and leaf angle are important determinants of yield in rice (Oryza sativa L.). Genes involved in regulating plant height and leaf angle were identified in previous studies; however, there are many remaining unknown factors that affect rice architecture. RESULTS In this study, we characterized a dwarf mutant named ds1 with small grain size and decreased leaf angle,selected from an irradiated population of ssp. japonica variety Nanjing35. The ds1 mutant also showed abnormal floral organs. ds1 plants were insensitive to BL treatment and expression of genes related to BR signaling was changed. An F2 population from a cross between ds1 and indica cultivar 93-11 was used to fine map DS1 and to map-based clone the DS1 allele, which encoded an EMF1-like protein that acted as a transcriptional regulator. DS1 was constitutively expressed in various tissues, and especially highly expressed in young leaves, panicles and seeds. We showed that the DS1 protein interacted with auxin response factor 11 (OsARF11), a major transcriptional regulator of plant height and leaf angle, to co-regulate D61/OsBRI1 expression. These findings provide novel insights into understanding the molecular mechanisms by which DS1 integrates auxin and brassinosteroid signaling in rice. CONCLUSION The DS1 gene encoded an EMF1-like protein in rice. The ds1 mutation altered the expression of genes related to BR signaling, and ds1 was insensitive to BL treatment. DS1 interacts with OsARF11 to co-regulate OsBRI1 expression.
Collapse
|
35
|
Search for Tensor, Vector, and Scalar Polarizations in the Stochastic Gravitational-Wave Background. PHYSICAL REVIEW LETTERS 2018; 120:201102. [PMID: 29864331 DOI: 10.1103/physrevlett.120.201102] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Revised: 03/30/2018] [Indexed: 06/08/2023]
Abstract
The detection of gravitational waves with Advanced LIGO and Advanced Virgo has enabled novel tests of general relativity, including direct study of the polarization of gravitational waves. While general relativity allows for only two tensor gravitational-wave polarizations, general metric theories can additionally predict two vector and two scalar polarizations. The polarization of gravitational waves is encoded in the spectral shape of the stochastic gravitational-wave background, formed by the superposition of cosmological and individually unresolved astrophysical sources. Using data recorded by Advanced LIGO during its first observing run, we search for a stochastic background of generically polarized gravitational waves. We find no evidence for a background of any polarization, and place the first direct bounds on the contributions of vector and scalar polarizations to the stochastic background. Under log-uniform priors for the energy in each polarization, we limit the energy densities of tensor, vector, and scalar modes at 95% credibility to Ω_{0}^{T}<5.58×10^{-8}, Ω_{0}^{V}<6.35×10^{-8}, and Ω_{0}^{S}<1.08×10^{-7} at a reference frequency f_{0}=25 Hz.
Collapse
|
36
|
GW170817: Implications for the Stochastic Gravitational-Wave Background from Compact Binary Coalescences. PHYSICAL REVIEW LETTERS 2018; 120:091101. [PMID: 29547330 DOI: 10.1103/physrevlett.120.091101] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2017] [Revised: 01/16/2018] [Indexed: 06/08/2023]
Abstract
The LIGO Scientific and Virgo Collaborations have announced the event GW170817, the first detection of gravitational waves from the coalescence of two neutron stars. The merger rate of binary neutron stars estimated from this event suggests that distant, unresolvable binary neutron stars create a significant astrophysical stochastic gravitational-wave background. The binary neutron star component will add to the contribution from binary black holes, increasing the amplitude of the total astrophysical background relative to previous expectations. In the Advanced LIGO-Virgo frequency band most sensitive to stochastic backgrounds (near 25 Hz), we predict a total astrophysical background with amplitude Ω_{GW}(f=25 Hz)=1.8_{-1.3}^{+2.7}×10^{-9} with 90% confidence, compared with Ω_{GW}(f=25 Hz)=1.1_{-0.7}^{+1.2}×10^{-9} from binary black holes alone. Assuming the most probable rate for compact binary mergers, we find that the total background may be detectable with a signal-to-noise-ratio of 3 after 40 months of total observation time, based on the expected timeline for Advanced LIGO and Virgo to reach their design sensitivity.
Collapse
|
37
|
Abstract
This study aims to evaluate the application of multimodal intraoperative monitoring (MIOM) in surgical treatment for spine burst fracture and dislocation (SBFD) patients.Eleven patients who underwent posterior reduction and instrumentation (PRI) for SBFD from June 2014 to July 2016 were included into the study. The function of the spinal cord was monitored by MIOM. The muscle strength of the lower extremities and American Spinal Injury Association (ASIA) scores were, respectively, evaluated (before surgery, and at 1, 3, 6, and 12 months after surgery). Furthermore, the extent of reduction was also assessed.Muscle strength recovery, ASIA score changes, and the extent of reduction were correlated with MIOM results. Among the 11 patients who received surgery under MIOM, 8 patients with negative MIOM results during the operation did not demonstrate neurological deterioration postoperatively and exhibited improvements in ASIA scores during follow-ups. However, among the 3 patients who encountered MIOM events (case 4, 7, and 8), 2 patients avoided nerve lesion and 1 patient suffered from neurologic deterioration postoperatively.The application of MIOM technology during PRI surgery may detect spinal cord impairment at the early stage, and operative schemes can be modified before permanent nerve compromise is triggered by surgical manipulation.
Collapse
|
38
|
[Determination of Hair Shafts by InnoTyper® 21 Kit]. FA YI XUE ZA ZHI 2018; 33:615-618. [PMID: 29441770 DOI: 10.3969/j.issn.1004-5619.2017.06.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 04/15/2016] [Indexed: 11/18/2022]
Abstract
OBJECTIVES To explore the application value of InnoTyper® 21 kit in forensic practice. METHODS Samples of hair shafts and saliva were collected from 8 unrelated individuals. Template DNA was extracted by AutoMate Express™ forensic DNA automatic extraction system. DNA was amplified by InnoTyper® 21 kit and AmpFℓSTR™ Identifiler™ Plus kit, respectively, and then the results were compared. RESULTS After the amplification by InnoTyper® 21 kit, complete specific genotyping could be detected from the saliva samples, and the peak value of genotyping profiles of hair shafts without sheath cells was 57-1 219 RFU. Allelic gene deletion could be found sometimes. When amplified by AmpFℓSTR™ Identifiler™ Plus kit, complete specific genotyping could be detected from the saliva samples, and the specific fragment was not detected in hair shafts without sheath cells. CONCLUSIONS The InnoTyper® 21 kit has certain application value in the cases of hair shafts without sheath cells.
Collapse
|
39
|
First Search for Nontensorial Gravitational Waves from Known Pulsars. PHYSICAL REVIEW LETTERS 2018; 120:031104. [PMID: 29400511 DOI: 10.1103/physrevlett.120.031104] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2017] [Revised: 11/16/2017] [Indexed: 06/07/2023]
Abstract
We present results from the first directed search for nontensorial gravitational waves. While general relativity allows for tensorial (plus and cross) modes only, a generic metric theory may, in principle, predict waves with up to six different polarizations. This analysis is sensitive to continuous signals of scalar, vector, or tensor polarizations, and does not rely on any specific theory of gravity. After searching data from the first observation run of the advanced LIGO detectors for signals at twice the rotational frequency of 200 known pulsars, we find no evidence of gravitational waves of any polarization. We report the first upper limits for scalar and vector strains, finding values comparable in magnitude to previously published limits for tensor strain. Our results may be translated into constraints on specific alternative theories of gravity.
Collapse
|
40
|
GW170817: Observation of Gravitational Waves from a Binary Neutron Star Inspiral. PHYSICAL REVIEW LETTERS 2017; 119:161101. [PMID: 29099225 DOI: 10.1103/physrevlett.119.161101] [Citation(s) in RCA: 848] [Impact Index Per Article: 121.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Indexed: 05/21/2023]
Abstract
On August 17, 2017 at 12∶41:04 UTC the Advanced LIGO and Advanced Virgo gravitational-wave detectors made their first observation of a binary neutron star inspiral. The signal, GW170817, was detected with a combined signal-to-noise ratio of 32.4 and a false-alarm-rate estimate of less than one per 8.0×10^{4} years. We infer the component masses of the binary to be between 0.86 and 2.26 M_{⊙}, in agreement with masses of known neutron stars. Restricting the component spins to the range inferred in binary neutron stars, we find the component masses to be in the range 1.17-1.60 M_{⊙}, with the total mass of the system 2.74_{-0.01}^{+0.04}M_{⊙}. The source was localized within a sky region of 28 deg^{2} (90% probability) and had a luminosity distance of 40_{-14}^{+8} Mpc, the closest and most precisely localized gravitational-wave signal yet. The association with the γ-ray burst GRB 170817A, detected by Fermi-GBM 1.7 s after the coalescence, corroborates the hypothesis of a neutron star merger and provides the first direct evidence of a link between these mergers and short γ-ray bursts. Subsequent identification of transient counterparts across the electromagnetic spectrum in the same location further supports the interpretation of this event as a neutron star merger. This unprecedented joint gravitational and electromagnetic observation provides insight into astrophysics, dense matter, gravitation, and cosmology.
Collapse
|
41
|
GW170814: A Three-Detector Observation of Gravitational Waves from a Binary Black Hole Coalescence. PHYSICAL REVIEW LETTERS 2017; 119:141101. [PMID: 29053306 DOI: 10.1103/physrevlett.119.141101] [Citation(s) in RCA: 163] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2017] [Indexed: 05/21/2023]
Abstract
On August 14, 2017 at 10∶30:43 UTC, the Advanced Virgo detector and the two Advanced LIGO detectors coherently observed a transient gravitational-wave signal produced by the coalescence of two stellar mass black holes, with a false-alarm rate of ≲1 in 27 000 years. The signal was observed with a three-detector network matched-filter signal-to-noise ratio of 18. The inferred masses of the initial black holes are 30.5_{-3.0}^{+5.7}M_{⊙} and 25.3_{-4.2}^{+2.8}M_{⊙} (at the 90% credible level). The luminosity distance of the source is 540_{-210}^{+130} Mpc, corresponding to a redshift of z=0.11_{-0.04}^{+0.03}. A network of three detectors improves the sky localization of the source, reducing the area of the 90% credible region from 1160 deg^{2} using only the two LIGO detectors to 60 deg^{2} using all three detectors. For the first time, we can test the nature of gravitational-wave polarizations from the antenna response of the LIGO-Virgo network, thus enabling a new class of phenomenological tests of gravity.
Collapse
|
42
|
Metformin reduces SATB2-mediated osteosarcoma stem cell-like phenotype and tumor growth via inhibition of N-cadherin/NF-kB signaling. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES 2017; 21:4516-4528. [PMID: 29131265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
OBJECTIVE To investigate the role of SATB2 in stem cell-like properties of osteosarcoma and identify new strategies to eliminate cancer stem cells of osteosarcoma. MATERIALS AND METHODS Osteosarcoma cancer stem cells were derived by sarcosphere generation or chemo drug enrichment. SATB2 and pluripotency-associated gene expression in osteosarcoma CSCs were analyzed using qRT-PCR and Western blotting. The sphere formation assay, cell counting kit-8 assay and anti-chemotherapy proteins were used to measure the effects of altered SATB2, N-cadherin expression or metformin treatment in CSCs. Nude mice were injected with SATB2-deficient U2OS/MTX cells to assess the role of SATB2 in osteosarcoma growth and chemoresistance in vivo. Bioinformatics analyses were performed to identify SATB2 downstream target genes and immunochemistry to determine the correlation between SATB2 expression and patient outcome. Western blotting and luciferase reporter assays were used to examine the effects of N-cadherin and SATB2 inhibition on the NF-kB pathway. RESULTS SATB2 was upregulated in osteosarcoma stem cells. Knockdown of SATB2 decreased sarcosphere formation, cell proliferation and stem cell-like gene expression in vitro, meanwhile reduced tumor growth and chemoresistance in vivo. High SATB2 expression in osteosarcoma patient samples was associated with poor clinical outcome. N-cadherin was one critical downstream target gene of SATB2 that mediated the stem cell-like phenotype. Reduction of SATB2 or N-cadherin resulted in NF-kB inactivation, which led to impaired osteosarcoma sphere formation and tumor cell proliferation. Metformin treatment of osteosarcoma cells enhanced the effects of chemotherapy via suppression of N-cadherin. CONCLUSIONS SATB2 plays an important role in regulating osteosarcoma stem cell-like properties and tumor growth. The combination of conventional chemotherapy and metformin may be a promising therapeutic strategy for osteosarcoma patients.
Collapse
|
43
|
[Intraocular lens power calculation for high myopic eyes with cataract: comparison of three formulas]. [ZHONGHUA YAN KE ZA ZHI] CHINESE JOURNAL OF OPHTHALMOLOGY 2017; 53:260-265. [PMID: 28412798 DOI: 10.3760/cma.j.issn.0412-4081.2017.04.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To compare the accuracy of three different formulas for intraocular lens power calculation in high myopic eyes with cataract and analyze their influencial factors. Methods: One hundred and three high myopic patients of cataract (103 eyes), with average age of 60.2±8.8 years old (39.0-77.0), including 45 male and 54 female and with axial length ≥ 26 mm were enrolled in this retrospective case-series study. All of them underwent routine ocular examination and IOLMastermeasurement preoperatively and then underwent phacoemulsification through temporal clear-corneal incision with implantation of HumanOptic posterior chamber Intraocular lens (IOL). All analyses were conducted using SPSS version 19.0. Repeated-measures analysis of variance was applied to compare the refractive results one month postoperatively with the predicted IOL powers calculated by SRK/T, Holladay 1, or Haigis formula before surgery. The differences were further compared based on different grouping of axial length (AXL), corneal curvature (K) and corneal astigmatism (CA). The accuracies of the three formulas were analyzed using Bland-Altman analyses and the possible error sources of each formula were analyzed using multiple regression model. Results: The majority of patients enrolled had hyperopic shift after cataract surgery. The mean errors (ME) of the three formulas were SRK/T: 0.70±0.89D, Holladay 1: (1.20±0.88) D and Haigis: (0.60±0.88) D; the mean absolute errors (MAE) of the three formulas were (0.81±0.79) D, (1.23±0.84) D and (0.76±0.74) D, respectively. Both ME and MAE of Holladay formula were significantly greater than the other two formulas (F=86.31, P<0.01). Besides, the proportion of patients having a prediction error within 0.50 D was lower in those using Holladay formula (20.4%, 21/103) than the other two (SRK/T: 38.8%, 40/103, χ(2)=8.41, P<0.01, Haigis: 45.6%, 47/103, χ(2)=14.84, P<0.01). Bland-Altman analyses showed that the accuracies of all the three formulas were acceptable in patients of cataract with high myopia in clinical practice. ME and MAE tended to be larger with longer axial length, larger corneal curvature and astigmatism of the patients in all three formulas. However, in eyes with axial length> 30 mm or corneal curvature ≤43.00 D, the MAE of Haigis formula was lower than that of SRK/T formula (F=63.26,63.94, both P<0.01). The prediction error of SRK/T formula was positively correlated with axial length and corneal astigmatism (F=33.97, r=0.66, β=0.48, P<0.01 and β=0.42, P<0.01), while for Holladay and Haigis formulas, in addition to the previous two factors, the errors were also positively correlated with mean corneal curvature (Holladay 1: F=31.26, r=0.72, AXL: β=0.52, P<0.01, K: β=0.20, P<0.05 and CA: β=0.37, P<0.01; Haigis: F=30.96, r=0.72, AXL: β=0.33, P<0.01, K: β=0.40, P<0.01 and CA: β=0.37, P<0.01). Conclusions: In the selection of IOL formula for high myopic patients with cataract, Haigis or SRK/T would reduce the prediction error and serve as the more accurate formulas than Holladay 1. Haigis formula may be more accurate than SRK/T formula in case of AXL>30 mm or K≤43.00 D. (Chin J Ophthalmol, 2017, 53: 260-265).
Collapse
|
44
|
[Exploratory analysis on burden of disease attributable to asbestosis from 2006 to 2015]. ZHONGHUA LAO DONG WEI SHENG ZHI YE BING ZA ZHI = ZHONGHUA LAODONG WEISHENG ZHIYEBING ZAZHI = CHINESE JOURNAL OF INDUSTRIAL HYGIENE AND OCCUPATIONAL DISEASES 2017; 35:429-432. [PMID: 28780818 DOI: 10.3760/cma.j.issn.1001-9391.2017.06.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Objective: To analyze the levels and trends of the burden of disease attributable to asbestosis from 2006 to 2015. Methods: Theincidence of asbestosis from 2006 to 2015 was used for calculation, with data of disability weight and remission rate from Global burden of disease study 2015 (GBD 2015) and DisMoD-MR 2.1 software for the calculation of duration and age of year onset. The reference template of GBD was adopted to calculate disability adjusted life year (DALY) , year of life lost (YLL) and year of lived with disability (YLD) value in order to analyze the level and changing trend of burden of disease attributable to asbestosis. Results: A total YLD attributable to asbestosis during 2006 and 2015 in China was 39632. The YLD burden of female was more severe than male, which accounted for 20361 in female and 19271 in male. In 2015, DALY attributable to asbestosis decreased from 8623.76 in 2006 to 6436. Among that, in 2015, YLD was 6436 and YLL was 73.76. 2006 had a highest level of DALY and 2008 had the lowest level of DALY, which accounted for 8623.76 in 2006 and 1558 in 2008. DALY during 2008 and 2015 had a fluctuant increase, and both male and female had such trend. Conclusion: The level of burden of disease attributable to asbestosis is higher in male than in female during 2006 and 2015. Between 2006 and 2015, burden of disease attributable to asbestosis has a fluctuant increase trend.
Collapse
|
45
|
GW170104: Observation of a 50-Solar-Mass Binary Black Hole Coalescence at Redshift 0.2. PHYSICAL REVIEW LETTERS 2017; 118:221101. [PMID: 28621973 DOI: 10.1103/physrevlett.118.221101] [Citation(s) in RCA: 220] [Impact Index Per Article: 31.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2017] [Indexed: 05/21/2023]
Abstract
We describe the observation of GW170104, a gravitational-wave signal produced by the coalescence of a pair of stellar-mass black holes. The signal was measured on January 4, 2017 at 10∶11:58.6 UTC by the twin advanced detectors of the Laser Interferometer Gravitational-Wave Observatory during their second observing run, with a network signal-to-noise ratio of 13 and a false alarm rate less than 1 in 70 000 years. The inferred component black hole masses are 31.2_{-6.0}^{+8.4}M_{⊙} and 19.4_{-5.9}^{+5.3}M_{⊙} (at the 90% credible level). The black hole spins are best constrained through measurement of the effective inspiral spin parameter, a mass-weighted combination of the spin components perpendicular to the orbital plane, χ_{eff}=-0.12_{-0.30}^{+0.21}. This result implies that spin configurations with both component spins positively aligned with the orbital angular momentum are disfavored. The source luminosity distance is 880_{-390}^{+450} Mpc corresponding to a redshift of z=0.18_{-0.07}^{+0.08}. We constrain the magnitude of modifications to the gravitational-wave dispersion relation and perform null tests of general relativity. Assuming that gravitons are dispersed in vacuum like massive particles, we bound the graviton mass to m_{g}≤7.7×10^{-23} eV/c^{2}. In all cases, we find that GW170104 is consistent with general relativity.
Collapse
|
46
|
Association of interleukin-6 gene polymorphisms and circulating levels with keloid scars in a Chinese Han population. GENETICS AND MOLECULAR RESEARCH 2017; 16:gmr-16-02-gmr.16029110. [PMID: 28437551 DOI: 10.4238/gmr16029110] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
The aim of the present study is to explore the effect of IL-6 gene polymorphisms on the development of keloid scar (KS) in the Chinese Han population. Genotyping of IL-6 was performed by the polymerase chain reaction (PCR), followed by restriction fragment length polymorphism assays (PCR-RFLP). Serum level of IL-6 was measured using enzyme-linked immunosorbent assay (ELISA). Results indicated that when the IL-6 -572 CC homozygote genotype was used as the reference group, the GG genotype was found to be associated with a significantly increased risk of KS (GG vs CC: OR = 2.097, 95%CI = 1.100-3.995, P = 0.025). When the IL-6 -572 C allele was used as the reference group, the G allele was found to be associated with significantly increased risk of KS (G vs C: OR = 1.317, 95%CI = 1.002-1.730, P = 0.048). Furthermore, we observed a marked increase in serum IL-6 levels in KS patients with GG genotypes when compared to KS patients harboring the CC genotype. In conclusion, our results suggest that IL-6 gene polymorphism was associated with keloid scars in the southeastern Chinese Han population.
Collapse
|
47
|
Upper Limits on the Stochastic Gravitational-Wave Background from Advanced LIGO's First Observing Run. PHYSICAL REVIEW LETTERS 2017; 118:121101. [PMID: 28388180 DOI: 10.1103/physrevlett.118.121101] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Indexed: 05/14/2023]
Abstract
A wide variety of astrophysical and cosmological sources are expected to contribute to a stochastic gravitational-wave background. Following the observations of GW150914 and GW151226, the rate and mass of coalescing binary black holes appear to be greater than many previous expectations. As a result, the stochastic background from unresolved compact binary coalescences is expected to be particularly loud. We perform a search for the isotropic stochastic gravitational-wave background using data from Advanced Laser Interferometer Gravitational Wave Observatory's (aLIGO) first observing run. The data display no evidence of a stochastic gravitational-wave signal. We constrain the dimensionless energy density of gravitational waves to be Ω_{0}<1.7×10^{-7} with 95% confidence, assuming a flat energy density spectrum in the most sensitive part of the LIGO band (20-86 Hz). This is a factor of ∼33 times more sensitive than previous measurements. We also constrain arbitrary power-law spectra. Finally, we investigate the implications of this search for the background of binary black holes using an astrophysical model for the background.
Collapse
|
48
|
Directional Limits on Persistent Gravitational Waves from Advanced LIGO's First Observing Run. PHYSICAL REVIEW LETTERS 2017; 118:121102. [PMID: 28388200 DOI: 10.1103/physrevlett.118.121102] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Indexed: 06/07/2023]
Abstract
We employ gravitational-wave radiometry to map the stochastic gravitational wave background expected from a variety of contributing mechanisms and test the assumption of isotropy using data from the Advanced Laser Interferometer Gravitational Wave Observatory's (aLIGO) first observing run. We also search for persistent gravitational waves from point sources with only minimal assumptions over the 20-1726 Hz frequency band. Finding no evidence of gravitational waves from either point sources or a stochastic background, we set limits at 90% confidence. For broadband point sources, we report upper limits on the gravitational wave energy flux per unit frequency in the range F_{α,Θ}(f)<(0.1-56)×10^{-8} erg cm^{-2} s^{-1} Hz^{-1}(f/25 Hz)^{α-1} depending on the sky location Θ and the spectral power index α. For extended sources, we report upper limits on the fractional gravitational wave energy density required to close the Universe of Ω(f,Θ)<(0.39-7.6)×10^{-8} sr^{-1}(f/25 Hz)^{α} depending on Θ and α. Directed searches for narrowband gravitational waves from astrophysically interesting objects (Scorpius X-1, Supernova 1987 A, and the Galactic Center) yield median frequency-dependent limits on strain amplitude of h_{0}<(6.7,5.5, and 7.0)×10^{-25}, respectively, at the most sensitive detector frequencies between 130-175 Hz. This represents a mean improvement of a factor of 2 across the band compared to previous searches of this kind for these sky locations, considering the different quantities of strain constrained in each case.
Collapse
|
49
|
[Anti-β(2)GPⅠantibodies accelerate the formation of atherosclerosis in high fat diet fed ApoE deficient mice]. ZHONGHUA XIN XUE GUAN BING ZA ZHI 2017; 45:44-48. [PMID: 28100345 DOI: 10.3760/cma.j.issn.0253-3758.2017.01.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To investigate the effects of anti-β(2) glycoprotein Ⅰ(β(2)GPⅠ) antibody on atherosclerosis in ApoE deficient mice. Methods: A total of 24 male ApoE deficient mice of specific pathogen free level(six to eight-week old)were divided into normal control group, high fat diet group, high fat diet with anti-β(2)GPⅠ group, high fat diet with homologous control antibody group (n=6 each group). During the feeding period, mice were weighed every 2 weeks and were intraperitoneally injected with anti-β(2)GPⅠIgG (100 μg/per) and homologous control IgG (100 μg/per) according to grouping once a week. At the 16th week, the carotid arterial lipid deposition was observed by small animal magnetic resonance imaging, and blood samples were collected from internal vein of eyeball and the concentrations of TC, TG, HDL-C and LDL-C in plasma were measured after EDTA anticoagulant treatment. AI was calculated. The mice were then sacrificed and carotid arteries were removed, hematoxylin-eosin staining was used to observe the atherosclerotic lesions near the bifurcation of carotid artery and to calculate lesion size. Results: (1) The body weight of mice was significantly higher in the high fat diet group compared to other 3 groups(all P<0.05), which was similar among high fat diet+ anti-β(2)GPⅠantibody group, high fat diet+ homologous control IgG group and normal diet control group (P>0.05). (2) After 16 weeks, plasma concentrations of TC and LDL-C in high fat diet group, high fat diet+ anti-β(2)GPⅠantibody group and high fat diet+ homologous control IgG group were significantly higher than in normal diet group (all P<0.05), there was no significant difference among high fat diet groups. The level of HDL-C was significantly higher in high fat diet control group than in normal diet control group. The concentration of TG was similar among groups. However, the value of AI in high fat+ anti-β(2)GPⅠ antibody group was significantly higher than in other groups (all P<0.05). (3) After 16 weeks, magnetic resonance imaging revealed that mice in high fat diet+ anti-β(2)GPⅠ antibody group had more obviously lipid deposition in the carotid arteries, it was significantly higher than that in the other groups, and the cross sections of carotid arteries stained with HE also demonstrated obviously carotid lumen stenosis and the percentage of carotid plaque area to carotid artery was (37.545±1.351)% in the high fat diet+ anti-β(2)GPⅠ antibody group, it was significantly higher than normal diet group ((1.235±0.460)%), high fat diet control group((11.635±2.751)%) and high fat diet+ homologous control IgG group ((11.815±2.623)%), all P<0.01. In high fat diet+ anti-β(2)GPⅠ antibody group, the area of carotid plaque was (3.121±0.124)×10(4) μm(2,) it was also significantly higher than normal diet group ((0.094±0.015)×10(4) μm(2)), high fat diet control group ((1.309±0.147)×10(4) μm(2)) and high fat diet+ homologous control IgG group ((1.027±0.228)×10(4)μm(2)), all P<0.01. Conclusion: Anti-β(2)GPⅠ antibody can promote atherosclerotic plaque formation in high fat diet fed ApoE deficient mice.
Collapse
|
50
|
[Autocorrelation analysis of pneumoconiosis in China]. ZHONGHUA LAO DONG WEI SHENG ZHI YE BING ZA ZHI = ZHONGHUA LAODONG WEISHENG ZHIYEBING ZAZHI = CHINESE JOURNAL OF INDUSTRIAL HYGIENE AND OCCUPATIONAL DISEASES 2016; 34:830-834. [PMID: 28043271 DOI: 10.3760/cma.j.issn.1001-9391.2016.11.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Objective: Using spatial autocorrelation analysis to study spatial distribution characteristics of pneumoconiosis in China. Methods: The incidence of pneumoconiosis of each province from 2009 to 2013 was calculated by reported data of pneumoconiosis and the number of employment in mining and manufacturing of each province from Chinese statistical yearbook. The global and local spatial autocorrelation analysis was im-plemented by global and local's Moran's I index respectively. Results: A total of 112 066 new cases of pneumo-coniosis were reported from 2009 to 2013 in China, Global Moran's I from 2009 to 2013 was -0.114、0.179、0.199、0.259 and 0.241 respectively. A total of 15 space units with statistical significance were detected by local spatial autocorrelation analysis, which were mainly high-high regions. Conclusion: There was weak global spa-tial autocorrelation relationship of the incidence of pneumoconiosis from 2010 to 2013 among the provinces in China. The results of local spatial autocorrelation analysis suggested that there were clustering regions of pneumo-coniosis in the southwest and central south of China.
Collapse
|