In Situ Drift Monitoring and Calibration of Field-Deployed Potentiometric Sensors Using Temperature Supervision. ACS Sens 2023; 8:2799-2808. [PMID: 37350462 DOI: 10.1021/acssensors.3c00735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/24/2023]
Abstract
Potentiometric ion-selective electrodes (ISEs) have broad applications in personalized healthcare, smart agriculture, oil/gas exploration, and environmental monitoring. However, high-precision potentiometric sensing is difficult with field-deployed sensors due to time-dependent voltage drift and the need for frequent calibration. In the laboratory setting, these issues are resolved by repeated calibration by measuring the voltage response at multiple standard solutions at a constant temperature. For field-deployed sensors, it is difficult to frequently interrupt operation and recalibrate with standard solutions. Moreover, the constant surrounding temperature constraint imposed by the traditional calibration process makes it unsuitable for temperature-varying field use. To address the challenges of traditional calibration for field-deployed sensors, in this study, we propose a novel in situ calibration approach in which we use natural/external temperature variation in the field to obtain the time-varying calibration parameters, without having to relocate the sensors or use any complex system. We also develop a temperature-supervised monitoring method to detect the drift of the sensor during operation. Collectively, the temperature-based drift monitoring and in situ calibration methods allow us to monitor the drift of sensors and correct them periodically to achieve high-precision sensing. We demonstrate our approach in three testbeds: (1) under controlled temperature variation in the lab, (2) under natural temperature variation in a greenhouse, and (3) in the field to monitor nitrate activity of an agricultural site. In the laboratory study, we validate that the calibration parameters of printed nitrate ISEs can be reproduced by our proposed calibration process; therefore, it can serve as an alternative to traditional calibration processes. In the greenhouse, we show the use of natural temperature variation to calibrate the sensors and detect the drift in a fixed concentration nitrate solution. Finally, we demonstrate the use of the method to monitor the nitrate activity of an agricultural field within 10% of laboratory-based measurements (i.e., a sensitivity of 0.03 mM) for a period of 22 days. The findings highlight the prospect of temperature-based calibration and drift monitoring for high-precision sensing with field-deployed ISEs.
Collapse
|
2
|
Optimization of Castor Oil-Based Ion Selective Electrode ( ISE) with Active Agent 1,10-Phenanthroline for Aqueous Pb 2+ Analysis. MEMBRANES 2022; 12:987. [PMID: 36295746 PMCID: PMC9611885 DOI: 10.3390/membranes12100987] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 09/28/2022] [Accepted: 10/05/2022] [Indexed: 06/16/2023]
Abstract
This research has successfully fabricated ion selective electrode (ISE) for Pb2+ using castor oil (Ricinus communis L.)-based polyurethane (PU) membrane with 1,10-phenanthroline as the active agent. The sensitivity of the Pb2+ ISE obtained is 27.25 mV/decade with a linear range of [Pb(NO3)2] of 10−10−10−5 M and a coefficient of determination (R2) of 0.959. The system response reaches stability after 25 s of measurement. The Pb2+ has a detection limit of 10−10 M and gives a stable response at pH 7−8 with a 15-day lifetime. The investigation of the selectivity of the ISE was performed using the mixed solution method with log Kij values of <1. The selectivity order of Pb2+ ISE against the foreign ions is Ag2+ > Ca2+ > K+ > Mg2+ > Cu2+ > Fe3+ > Cr3+> Zn2+ > Cd2+. The Pb2+ ISE shows acceptable reproducibility and repeatability with standard deviation values of 0.065 and 0.0079, respectively. Fourier transform infrared (FT-IR) spectra confirmed that 1,10-phenanthroline was responsible for the formation of the Pb2+ ion entrapment via complexation. Other characterizations (crystallinity, micro-surface morphology, and mechanical strength) suggest the degradation of the membrane structure integrity after the application. The analysis results of Pb levels using the Pb2+ ISE in artificial and wastewater samples were not significantly different from the atomic absorption spectroscopy (AAS) measurement.
Collapse
|
3
|
Temperature Self-Calibration of Always-On, Field-Deployed Ion-Selective Electrodes Based on Differential Voltage Measurement. ACS Sens 2022; 7:2661-2670. [PMID: 36074898 DOI: 10.1021/acssensors.2c01163] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Originally developed for use in controlled laboratory settings, potentiometric ion-selective electrode (ISE) sensors have recently been deployed for continuous, in situ measurement of analyte concentration in agricultural (e.g., nitrate), environmental (e.g., ocean acidification), industrial (e.g., wastewater), and health-care sectors (e.g., sweat sensors). However, due to uncontrolled temperature and lack of frequent calibration in these field applications, it has been difficult to achieve accuracy comparable to the laboratory setting. In this paper, we propose a novel temperature self-calibration method where the ISE sensors can serve as their own thermometer and therefore precisely measure the analyte concentration in the field condition by compensating for the temperature variations. We validate the method with controlled experiments using pH and nitrate ISEs, which use the Nernst principle for electrochemical sensing. We show that, using temperature self-calibration, pH and nitrate can be measured within 0.3% and 5% of the true concentration, respectively, under varying concentrations and temperature conditions. Moreover, we perform a field study to continuously monitor the nitrate concentration of an agricultural field over a period of 6 days. Our temperature self-calibration approach determines the nitrate concentration within 4% of the ground truth measured by laboratory-based high-precision nitrate sensors. Our approach is general and would allow battery-free temperature-corrected analyte measurement for all Nernst principle-based sensors being deployed as wearable or implantable sensors.
Collapse
|
4
|
(In)direct chloride ISE measurements, room for improvement. Clin Chem Lab Med 2022; 60:e168-e171. [PMID: 35512217 DOI: 10.1515/cclm-2022-0220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Accepted: 04/13/2022] [Indexed: 11/15/2022]
|
5
|
Rbfox2 mediates exon 11 inclusion in insulin receptor pre-mRNA splicing in hepatoma cells. Biochimie 2021; 187:25-32. [PMID: 34022289 DOI: 10.1016/j.biochi.2021.05.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 05/10/2021] [Accepted: 05/14/2021] [Indexed: 11/27/2022]
Abstract
Insulin receptor (IR) pre-mRNA undergoes alternative splicing that produces two isoforms, IR-A and IR-B. The ratio of IR-A to IR-B varies among tissues, which strongly suggests that IR mRNA alternative splicing is regulated in a tissue-specific manner. However, the precise molecular mechanism for IR alternative splicing remains to be elucidated, especially in liver. In this study, we have analyzed IR alternative splicing mechanism by preparing a mini-gene splicing reporter with rat genomic DNA. The splicing reporter that contains exon 11 and its flanking intronic sequences could reproduce alternative splicing pattern in rat hepatoma H4IIE cells. Introducing several deletions in introns of the reporter revealed that intron 11 contains the region near exon 11 essential to promote exon 11 inclusion. This region contains an UGCAUG sequence, a specific binding site for the Rbfox splicing regulator, and mutation in this sequence results in exon 11 skipping. Furthermore, RbFox2 knockdown in H4IIE cells enhanced exon 11 skipping of endogenous IR pre-mRNA. Lastly mutations in the SRSF3 binding site of exon11 together with the Rbfox2 binding site completely abolished exon 11 inclusion with a mini-gene reporter pre-mRNA. Our results indicate that RbFox2 and SRSF3 proteins mediate exon 11 inclusion in rat hepatoma cells.
Collapse
|
6
|
Pseudohyperkalemia and Pseudohyponatremia in Two Children with T-Cell Acute Lymphoblastic Leukemia. J Pediatr 2021; 232:294-298. [PMID: 33493492 DOI: 10.1016/j.jpeds.2021.01.044] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 01/15/2021] [Accepted: 01/19/2021] [Indexed: 01/19/2023]
Abstract
Pseudohyperkalemia and pseudohyponatremia are phenomena in which hematologic disorders with high cell counts result in factitious electrolyte measurements that can result in inappropriate treatment. We describe 2 children with leukemia presenting with both disturbances to highlight the importance of correlating electrolyte results from plasma with those from whole blood before intervening.
Collapse
|
7
|
Discrepancies in Electrolyte Measurements by Direct and Indirect Ion Selective Electrodes due to Interferences by Proteins and Lipids. J Lab Physicians 2020; 12:84-91. [PMID: 32905238 PMCID: PMC7467836 DOI: 10.1055/s-0040-1713690] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Objectives
We aim to report the simultaneous effect of different protein and lipid concentrations on sodium (Na
+
) and potassium (K
+
) measurement by direct and indirect ion selective electrodes (dISE and iISE) in patient samples.
Materials and Methods
Na
+
and K
+
were measured in 195 serum samples received in the laboratory using iISE by Roche Modular P800 autoanalyzer and using dISE by XI-921 ver. 6.0 Caretium electrolyte analyzer. Serum total protein (TP), cholesterol (Chol), and triglycerides (TG) were measured using conventional photometric methods on Roche Modular P800 autoanalyzer. Differences for each pair of results for Na
+
(Diff_Na
+
= [Na
+dISE–
Na
+iISE
]) and K
+
(Diff_K
+
= [K
+dISE–
K
+iISE
]) were calculated. Patient subgroups with high, normal, or low TP (< 5, 5–7.9, or ≥ 8 g/dL), Chol (< 150, 150–299, or ≥300 mg/dL), or TG (< 150, 150–299, or ≥300 mg/dL) were compared using analysis of variance. Note that 95% confidence interval of Diff_Na
+
and Diff_K
+
were calculated to see the number of samples showing clinically significant differences.
Results
Diff_Na
+
(
p
= 0.007) and Diff_K
+
(
p
= 0.002) were found significant between samples with normal and high TP. However, effect of TG was not significant. Chol concentration affected Diff_Na
+
significantly between low versus normal (
p
= 0.002), and high versus normal (
p
= 0.031) Chol groups. Diff_K
+
was significant (
p
= 0.009) between low versus normal Chol. Clinically relevant disagreement of ≥|5| mmol/L for Na
+
was observed in high percentage of samples including all subcategories; however, for K
+
only 3.6% of the total samples showed disagreement of ≥ |0.5| mmol/L. A multivariate regression equation based on fit regression model was also derived.
Conclusion
Summarily, interchangeable use of electrolyte results from dISE and iISE is not advisable, especially in a setting of hyperproteinemia (≥8 g/dL) or hypercholesterolemia (≥300 mg/dL); more so for Na
+
.
Collapse
|
8
|
GNSS- ISE: Instruction Set Extension for GNSS Baseband Processing. SENSORS 2020; 20:s20020465. [PMID: 31947573 PMCID: PMC7027023 DOI: 10.3390/s20020465] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 01/10/2020] [Accepted: 01/11/2020] [Indexed: 11/17/2022]
Abstract
This work presents the results of research toward designing an instruction set extension dedicated to Global Navigation Satellite System (GNSS) baseband processing. The paper describes the state-of-the-art techniques of GNSS receiver implementation. Their advantages and disadvantages are discussed. Against this background, a new versatile instruction set extension for GNSS baseband processing is presented. The authors introduce improved mechanisms for instruction set generation focused on multi-channel processing. The analytical approach used by the authors leads to the introduction of a GNSS-instruction set extension (ISE) for GNSS baseband processing. The developed GNSS-ISE is simulated extensively using PC software and field-programmable gate array (FPGA) emulation. Finally, the developed GNSS-ISE is incorporated into the first-in-the-world, according to the authors’ best knowledge, integrated, multi-frequency, and multi-constellation microcontroller with embedded flash memory. Additionally, this microcontroller may serve as an application processor, which is a unique feature. The presented results show the feasibility of implementing the GNSS-ISE into an embedded microprocessor system and its capability of performing baseband processing. The developed GNSS-ISE can be implemented in a wide range of applications including smart IoT (internet of things) devices or remote sensors, fostering the adaptation of multi-frequency and multi-constellation GNSS receivers to the low-cost consumer mass-market.
Collapse
|
9
|
Investigation of Polyurethane Matrix Membranes for Salivary Nitrate ISFETs to Prevent the Drift. SENSORS 2019; 19:s19122713. [PMID: 31212895 PMCID: PMC6630929 DOI: 10.3390/s19122713] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Revised: 06/05/2019] [Accepted: 06/14/2019] [Indexed: 12/04/2022]
Abstract
We have investigated human-stress monitoring by making use of salivary nitrate, which can be a candidate for stress markers, with ion-selective field-effect transistors (ISFETs). ISFETs are suitable for on-site single-drop analysis of salivary nitrate within 10 s. However, when ISFETs are used for salivary nitrate, ISFETs have a problem that is called the initial drift. The initial drift makes accurate nitrate monitoring difficult. Thus, the purpose of this study is to prevent the initial drift and to search for a new, simple polymer to possess a better performance of sensor responses than conventional matrix membranes, such as PVC. In this research, we investigated ISFETs using specific matrix membranes, for example KP-13, Pellethane®, and P7281-PU. The initial drift was evaluated from the fluctuations of the response values generated by the ISFETs when immersed in saliva or aqueous solution. As a result, P7281-PU showed a prevention effect on the initial drift, both in the whole saliva and in various solutions. Furthermore, the cause of drift may be H+ diffusion, and the drift prevention effect of P7281-PU may be affected by urethane bond capturing H+ in the ion-selective membrane. This result suggests that a continuous nitrate monitoring is feasible and may be applied to wearable sensors.
Collapse
|
10
|
A fully integrated passive microfluidic Lab-on-a-Chip for real-time electrochemical detection of ammonium: Sewage applications. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 653:1223-1230. [PMID: 30759562 DOI: 10.1016/j.scitotenv.2018.11.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Revised: 10/31/2018] [Accepted: 11/01/2018] [Indexed: 06/09/2023]
Abstract
The present work reports on the development of a new generation of Lab-on-a-chip (LOC) to perform in-situ and real-time potentiometric measurements in flowing water. The device consisted of two differentiated parts: a poly (dimethylsiloxane) (PDMS) microfluidic structure obtained by soft lithography and a fully integrated chemical sensing platform including four working microelectrodes, two reference microelectrodes and one counter microelectrode for detecting ammonium in a continuous mode. The performance of the device was evaluated following its potentiometric response when analyzing ammonium containing samples. As a key parameter, its time of response was compared to that of a commercially available electrical conductivity sensor used as reference sensor during tests in laboratory using flowing tap water and technical scale using flowing wastewater. As a result, the LOC showed a slope of 55 mV/decade, a limit of detection of 4·10-5 M and a time of full response between 10 and 12 s. It was demonstrated that the device can provide fast and reliable data at real time when immersed in a laminar flow of water. Moreover, the test of robustness showed that it was still functional after immersion in sewage for at least 15 min. Besides, the LOC reported here can be helpful for a wide variety of flowing-water applications such as aqua culture outlets control, in-situ and continuous analysis of rivers effluents and sea waters monitoring among others.
Collapse
|
11
|
Optical and electrochemical dual channel sensing of Cu 2+ using functionalized furo[2,3-d]pyrimidines-2,4[1H,3H]-diones. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2017; 181:73-81. [PMID: 28342426 DOI: 10.1016/j.saa.2017.03.034] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2017] [Revised: 03/07/2017] [Accepted: 03/16/2017] [Indexed: 06/06/2023]
Abstract
Owing to their easy accessibility and high degree of structural and functional diversity, many multicomponent reactions (MCRs) have been a rich source of conjugate π-systems, functionalised chromophores (or fluorophore) and redox active molecules. Despite their high explorative potential and practical benefits, only a few MCR products have been so far investigated for their metal sensing abilities. In the present report, two furopyrimidinones (FPys) based molecular systems have been synthesized by [4+1] cycloaddition based MCR sequence. Designed chemosensors displayed optic (absorption spectra) as well as electroanalytical (ion selective electrode) response toward Cu2+ ion in solution and membrane phase respectively (dual channel sensing). Different aspects of both the sensing phenomena such as selectivity, association constants, detection limit, membrane composition etc. were studied in detail using UV-Vis spectroscopy, NMR titration and cell assembly. Both the compounds showed excellent performance characteristics such as high selectivity, acceptable affinity and low detection limits (10-7M) in both sensing assays with potential utility in the area of sample monitoring.
Collapse
|
12
|
Effective mercury(II) bioremoval from aqueous solution, and its electrochemical determination. CHEMOSPHERE 2017; 167:314-321. [PMID: 27732923 DOI: 10.1016/j.chemosphere.2016.10.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2016] [Revised: 09/23/2016] [Accepted: 10/01/2016] [Indexed: 06/06/2023]
Abstract
This work proposed mercury elimination using agricultural waste (Allium Cepa L.). The biomass removed 99.4% of mercury, following a pseudo-second order kinetics (r2 = 0.9999). The Langmuir model was adequately fitted to the adsorption isotherm, thereby obtaining the maximum mercury adsorption capacity of 111.1 ± 0.3 mg g-1. The biomass showed high density of strong mercury chelating groups, thus making it economically attractive. Also, the implementation of a mercury-selective electrode for continuous determination in real time is proposed; this electrode replaces techniques like atomic absorption spectroscopy, thus it can be applied to real time studies. This work therefore presents a new perspective for removing mercury(II) from contaminated water for environmental remediation.
Collapse
|
13
|
Comparison Between Measured and Calculated Free Calcium Values at Different Serum Albumin Concentrations. J Lab Physicians 2016; 8:71-6. [PMID: 27365914 PMCID: PMC4866387 DOI: 10.4103/0974-2727.180785] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
INTRODUCTION Free ionic calcium is the metabolically active component of total calcium (TCa) in blood. However, most laboratories report TCa levels that are dependent on serum albumin concentration. Hence, several formulae have evolved to calculate free calcium levels from TCa after adjustment for albumin. However, free calcium can directly be measured using direction selective electrodes rather than spectrophotometric methods used in autoanalyzers. OBJECTIVES This study compares the levels of free calcium obtained by measurement by direct ion selective electrode (ISE) and the one calculated as a function of TCa by formulae. MATERIALS AND METHODS A total of 254 serum samples submitted to clinical biochemistry laboratory of a tertiary care hospital were analyzed for total protein, albumin, and TCa by standard spectrophotometric methods and for free calcium by direct ISE. Three commonly used formulae viz. Orrell, Berry et al. and Payne et al. were used to calculate adjusted TCa. Calculated free calcium was obtained by taking 50% of these values. RESULTS A significant difference (P < 0.05) was observed between calculated free calcium by all the three formulae and measured free calcium estimated by direct ISE using paired t-test and Bland-Altman plots. CONCLUSION Formulae for predicting free calcium by estimating TCa and albumin lacks consistency in prediction and free calcium should be evaluated by direct measurement.
Collapse
|
14
|
Solid contact potassium selective electrodes for biomedical applications - a review. Talanta 2016; 160:56-65. [PMID: 27591587 DOI: 10.1016/j.talanta.2016.06.050] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2016] [Revised: 06/17/2016] [Accepted: 06/24/2016] [Indexed: 01/29/2023]
Abstract
Ion-selective electrodes (ISE) are used in several biomedical applications, including laboratory sensing of potassium concentration in blood and urine samples. For on-site determination of potassium concentration and usage in other applications such as determination of extracellular potassium concentration, miniaturization of the sensors is required. To that extent, solid contacts have proven to be an adequate substitute of liquid contacts as inner layer for ion-to-electron transduction, allowing industrial production of miniaturized ISEs. This review paper covers relevant developments of solid-state ISEs in the past decade, critically compares current potassium ISEs and discusses future prospects for biomedical applications. Performances of three main types of solid contact materials in potassium sensing are compared, namely polypyrrole, polythiophenes and conducting nanomaterials. With these new materials, numerous improvements in stability, selectivity and time response of solid-state ISEs have been made. Current developments are new operational methods of sensing, flexible miniaturized sensors and multi-electrode designs able to measure electrolyte concentrations in one-drop blood samples or transmembrane ionic flows.
Collapse
|
15
|
Splicing defects caused by exonic mutations in PKD1 as a new mechanism of pathogenesis in autosomal dominant polycystic kidney d isease. RNA Biol 2016; 12:369-74. [PMID: 25757501 DOI: 10.1080/15476286.2015.1014291] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
The correct splicing of precursor-mRNA depends on the actual splice sites plus exonic and intronic regulatory elements recognized by the splicing machinery. Surprisingly, an increasing number of examples reveal that exonic mutations disrupt the binding of splicing factors to these sequences or generate new splice sites or regulatory elements, causing disease. This contradicts the general assumption that missense mutations disrupt protein function and that synonymous mutations are merely polymorphisms. Autosomal dominant polycystic kidney disease (ADPKD) is a common inherited disorder caused mainly by mutations in the PKD1 gene. Recently, we analyzed a substantial number of PKD1 missense or synonymous mutations to further characterize their consequences on pre-mRNA splicing. Our results showed that one missense and 2 synonymous mutations induce significant defects in pre-mRNA splicing. Thus, it appears that aberrant splicing as a result of exonic mutations is a previously unrecognized cause of ADPKD.
Collapse
|
16
|
Two degree of freedom control scheme for unstable processes with small time delay. ISA TRANSACTIONS 2015; 56:308-326. [PMID: 25617941 DOI: 10.1016/j.isatra.2014.12.007] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2014] [Revised: 12/14/2014] [Accepted: 12/25/2014] [Indexed: 06/04/2023]
Abstract
In this work, a recently reported two degree of freedom control structure namely the Parallel Control Structure (PCS) is modified to achieve improved control performance for unstable processes. New tuning rules are proposed using a direct synthesis approach for unstable first order plus time delay (UFOPTD), unstable second order plus time delay (USOPTD) and integrating and unstable plus time delay (IUPTD) process models. The proposed method has two tuning parameters whose suitable values are recommended after studying their effect on the system performance and robustness. This is an advantage of the present work over the other reported control schemes where the authors provide suitable ranges of the tuning parameters values. Simulation examples show that the present scheme results in improved nominal and perturbed responses as compared to the recently reported methods. Also it is observed that satisfactory performance is achieved when the proposed tuning rules are applied on an isothermal chemical reactor which exhibits multiple steady state solutions.
Collapse
|
17
|
Determination of all feasible robust PID controllers for open-loop unstable plus time delay processes with gain margin and phase margin specifications. ISA TRANSACTIONS 2014; 53:628-646. [PMID: 24462232 DOI: 10.1016/j.isatra.2013.12.037] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2012] [Revised: 12/17/2013] [Accepted: 12/27/2013] [Indexed: 06/03/2023]
Abstract
This paper proposes a novel alternative method to graphically compute all feasible gain and phase margin specifications-oriented robust PID controllers for open-loop unstable plus time delay (OLUPTD) processes. This method is applicable to general OLUPTD processes without constraint on system order. To retain robustness for OLUPTD processes subject to positive or negative gain variations, the downward gain margin (GM(down)), upward gain margin (GM(up)), and phase margin (PM) are considered. A virtual gain-phase margin tester compensator is incorporated to guarantee the concerned system satisfies certain robust safety margins. In addition, the stability equation method and the parameter plane method are exploited to portray the stability boundary and the constant gain margin (GM) boundary as well as the constant PM boundary. The overlapping region of these boundaries is graphically determined and denotes the GM and PM specifications-oriented region (GPMSOR). Alternatively, the GPMSOR characterizes all feasible robust PID controllers which achieve the pre-specified safety margins. In particular, to achieve optimal gain tuning, the controller gains are searched within the GPMSOR to minimize the integral of the absolute error (IAE) or the integral of the squared error (ISE) performance criterion. Thus, an optimal PID controller gain set is successfully found within the GPMSOR and guarantees the OLUPTD processes with a pre-specified GM and PM as well as a minimum IAE or ISE. Consequently, both robustness and performance can be simultaneously assured. Further, the design procedures are summarized as an algorithm to help rapidly locate the GPMSOR and search an optimal PID gain set. Finally, three highly cited examples are provided to illustrate the design process and to demonstrate the effectiveness of the proposed method.
Collapse
|
18
|
The Integrated Skin Exam film: an educational intervention to promote early detection of melanoma by medical students. J Am Acad Dermatol 2013; 70:115-9. [PMID: 24220723 DOI: 10.1016/j.jaad.2013.09.028] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2013] [Revised: 08/28/2013] [Accepted: 09/02/2013] [Indexed: 11/30/2022]
Abstract
BACKGROUND Knowledge of the skin cancer examination (SCE) and its practice remain relevant competency gaps among medical students. OBJECTIVE We elaborate on a method of SCE known as the Integrated Skin Exam and discuss the development of an instructional film that illustrates its principles. We assess the tool's effect on knowledge, attitudes, and perceptions related to the SCE. METHODS Second-year students among 8 randomized schools viewed the film and completed pre-post questionnaires. RESULTS After viewing The Integrated Skin Exam film, students demonstrated improved melanoma knowledge, including identification of high-risk demographic groups (61% vs 42.9%, P < .001), high-risk anatomic sites in women (88.6% vs 46.5%, P < .001) and men (92.1% vs 34.8%, P < .001), and the ABCDEs of melanoma (98.4% vs 91.2%, P < .001). Students demonstrated increased confidence in the SCE (66.93% vs 16.40%, P < .001) and augmented intentions to practice it (99.05% vs 13.9%, P < .001). A greater proportion (70.4% vs 41.9%, P < .001) of students thought less than 3 minutes were required to integrate SCE into the routine examination. LIMITATIONS Longitudinal impact of the film was not assessed. CONCLUSION The Integrated Skin Exam film introduces an integrated approach to the SCE that addresses knowledge gaps, mitigates perceived barriers, and augments intention related to practice of the SCE.
Collapse
|