1
|
Development and Validation of a Deep-Learning-Based Algorithm for Detecting and Classifying Metallic Implants in Abdominal and Spinal CT Topograms. Diagnostics (Basel) 2024; 14:668. [PMID: 38611581 PMCID: PMC11011303 DOI: 10.3390/diagnostics14070668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2024] [Revised: 03/18/2024] [Accepted: 03/20/2024] [Indexed: 04/14/2024] Open
Abstract
PURPOSE To develop and validate a deep-learning-based algorithm (DLA) that is designed to segment and classify metallic objects in topograms of abdominal and spinal CT. METHODS DLA training for implant segmentation and classification was based on a U-net-like architecture with 263 annotated hip implant topograms and 2127 annotated spine implant topograms. The trained DLA was validated with internal and external datasets. Two radiologists independently reviewed the external dataset consisting of 2178 abdomen anteroposterior (AP) topograms and 515 spine AP and lateral topograms, all collected in a consecutive manner. Sensitivity and specificity were calculated per pixel row and per patient. Pairwise intersection over union (IoU) was also calculated between the DLA and the two radiologists. RESULTS The performance parameters of the DLA were consistently >95% in internal validation per pixel row and per patient. DLA can save 27.4% of reconstruction time on average in patients with metallic implants compared to the existing iMAR. The sensitivity and specificity of the DLA during external validation were greater than 90% for the detection of spine implants on three different topograms and for the detection of hip implants on abdominal AP and spinal AP topograms. The IoU was greater than 0.9 between the DLA and the radiologists. However, the DLA training could not be performed for hip implants on spine lateral topograms. CONCLUSIONS A prototype DLA to detect metallic implants of the spine and hip on abdominal and spinal CT topograms improves the scan workflow with good performance for both spine and hip implants.
Collapse
|
2
|
Additively Manufactured SiO 2 and Cu-Added Ti Implants for Synergistic Enhancement of Bone Formation and Antibacterial Efficacy. ACS APPLIED MATERIALS & INTERFACES 2024; 16:3106-3115. [PMID: 38214659 DOI: 10.1021/acsami.3c14994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/13/2024]
Abstract
Commercially pure titanium (CpTi), a bioinert metal, is used as an implant material at low load-bearing sites and as a porous coating on Ti6Al4V at high load-bearing sites. There is an unmet need for metallic biomaterials to improve osseointegration and inherent antimicrobial resistance. In this study, we have added 1 wt % SiO2 and 3 wt % Cu to the CpTi matrix and processed via metal additive manufacturing (AM). Si4+ ions promote angiogenesis and osteogenesis. CpTi-SiO2 composition exhibited 4.5 times higher bone formation at the bone-implant interface over CpTi in an in vivo study with a rat distal femur model. In vitro bacterial studies with Gram-positive Staphylococcus aureus bacterium revealed 85% antibacterial efficacy by CpTi-SiO2-3Cu than CpTi. CpTi-SiO2-3Cu did not show any inflammatory markers in vivo, indicating the absence of cytotoxicity, but displayed delayed osseointegration compared to CpTi-SiO2. CpTi-SiO2-3Cu displayed 3-fold higher mineralized bone formation than CpTi. Our results emphasize the synergistic effect of SiO2 and Cu addition in CpTi, promoting enhanced early stage osseointegration and inherent antibacterial efficacy, contributing toward implant longevity and stability in vivo.
Collapse
|
3
|
Response of preosteoblasts on micromachined Ti-6Al-4V surface to microstructure dimension. Biomed Mater 2023; 19:015002. [PMID: 37890474 DOI: 10.1088/1748-605x/ad0792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Accepted: 10/27/2023] [Indexed: 10/29/2023]
Abstract
The cell incubation depends on the cultured surface, but various machining methods produce different surface topographies, but it has not been clear how it is related to the topographic feature until now. Hence, the machined Ti-6Al-4V surface is characterized for preosteoblasts incubation via different mechanical fabrication. The relationship between surface topography created by various machining methods and cell incubation behaviour was explored. The objective is to control the surface preosteoblasts growth in machining of biological titanium alloy. According to the cell growth kinetic, the cell incubation behaviour was first proposed and modelled in relation to microstructural dimension and culture duration. Then, the topological cultured microstructure surface was fabricated via mechanical fabrication. Finally, the cell initial adhesion and incubation behaviour on microstructured surface was investigated. It is shown that the surface undulation on machined microstructure is conducive to controlling the direction and distribution of cell incubation from cell growth kinetic model. The cell culture can be controlled on the peak with a small undulation, while it is concentred on the sidewall with a high aspect ratio. Increasing the aspect ratio extends cell growth, while low aspect ratio promotes initial cell adhesion and growth rate. Within the optimal cultured duration, the microstructured surface is more favourable for cell survival, and the cell growth keep positive beyond critical aspect ratio. As a result, the cell adhesion ability is topologically controlled to 5.4 times higher and the growth rate can be improved by 101.7% on milled microgrooved surface. It may be applied to the rapid production of biomedical Ti-6Al-4V implant.
Collapse
|
4
|
Effect of surface matching mismatch of focal knee articular prosthetic on tibiofemoral contact stress using finite element analysis. Bone Joint Res 2023; 12:497-503. [PMID: 37582511 PMCID: PMC10427223 DOI: 10.1302/2046-3758.128.bjr-2023-0010.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/17/2023] Open
Abstract
Aims Focal knee arthroplasty is an attractive alternative to knee arthroplasty for young patients because it allows preservation of a large amount of bone for potential revisions. However, the mechanical behaviour of cartilage has not yet been investigated because it is challenging to evaluate in vivo contact areas, pressure, and deformations from metal implants. Therefore, this study aimed to determine the contact pressure in the tibiofemoral joint with a focal knee arthroplasty using a finite element model. Methods The mechanical behaviour of the cartilage surrounding a metal implant was evaluated using finite element analysis. We modelled focal knee arthroplasty with placement flush, 0.5 mm deep, or protruding 0.5 mm with regard to the level of the surrounding cartilage. We compared contact stress and pressure for bone, implant, and cartilage under static loading conditions. Results Contact stress on medial and lateral femoral and tibial cartilages increased and decreased, respectively, the most and the least in the protruding model compared to the intact model. The deep model exhibited the closest tibiofemoral contact stress to the intact model. In addition, the deep model demonstrated load sharing between the bone and the implant, while the protruding and flush model showed stress shielding. The data revealed that resurfacing with a focal knee arthroplasty does not cause increased contact pressure with deep implantation. However, protruding implantation leads to increased contact pressure, decreased bone stress, and biomechanical disadvantage in an in vivo application. Conclusion These results show that it is preferable to leave an edge slightly deep rather than flush and protruding.
Collapse
|
5
|
Microalgae Applications to Bone Repairing Processes: A Review. ACS Biomater Sci Eng 2023. [PMID: 37227297 DOI: 10.1021/acsbiomaterials.2c01389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Research on regeneration and accelerated recovery processes of bone tissue has driven a growing interest in the scientific community. Implementing natural materials to reduce rejections due to biocompatibility issues is an important trend. Biofunctionalization processes have been proposed to promote osseointegration in implant materials, and those substances able to generate an adequate environment for cell proliferation are the object of several studies. Because of their high protein content and their anti-inflammatory, antibacterial, antimicrobial, and healing properties, microalgae represent a natural source of bioactive compounds, and are proposed as candidates for tissue regeneration applications. In this paper microalgae are reviewed as a source of biofunctionalized materials focused on orthopedic applications.
Collapse
|
6
|
[Comparison of Image Quality Using Metal Artifact Reduction Magnetic Resonance Sequences at Different Static Magnetic Fields]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2023:2023-1356. [PMID: 37225450 DOI: 10.6009/jjrt.2023-1356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
PURPOSE This study aims to optimize the selection of the magnetic resonance imaging (MRI) scanners and metal artifact reduction magnetic resonance sequence (MARS) in patients with metallic implants by comparing the image quality of MARS at different static magnetic fields. METHOD A titanium alloy hip prostheses stem was covered with the pork phantom. Nifedipine 10 mg was placed as a simulated lesion near the hip joint of the phantom. T1-weighted imaging (T1WI) and short tau inversion recovery (STIR) were acquired at both 1.5T and 3T. Several techniques of high-bandwidth (High BW), view angle tilting (VAT), and compressed sensing and slice encoding for metal artifacts correction (CS-SEMAC) were compared. Artifacts, sharpness, and visibility of lesions were evaluated visually by five radiological technologists using the normalized-rank approach. RESULT CS-SEMAC reduced metal artifacts but showed bad sharpness. CS-SEMAC at 3T was the best visibility of lesions. CONCLUSION If lesion visibility is a priority, CS-SEMAC with 3T is recommended as the first choice.
Collapse
|
7
|
Antibacterial and Proliferative Effects of NaOH-Coated Titanium, Zirconia, and Ceramic-Reinforced PEEK Dental Composites on Bone Marrow Mesenchymal Stem Cells. Pharmaceutics 2022; 15:pharmaceutics15010098. [PMID: 36678727 PMCID: PMC9863913 DOI: 10.3390/pharmaceutics15010098] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2022] [Revised: 12/17/2022] [Accepted: 12/20/2022] [Indexed: 12/29/2022] Open
Abstract
Several metallic and polymer-based implants have been fabricated for orthopedic applications. For instance, titanium (Ti), zirconia (Zr), and polyetheretherketone (PEEK) are employed due to their excellent biocompatibility properties. Hence, the present study aimed to compare the functional and biological properties of these three biomaterials with surface modification. For this purpose, Ti, Zr, and ceramic-reinforced PEEK (CrPEEK) were coated with NaOH and tested for the biological response. Our results showed that the surface modification of these biomaterials significantly improved the water contact, protein adhesion, and bioactivity compared with uncoated samples. Among the NaOH-coated biomaterials, Ti and CrPEEK showed higher protein absorption than Zr. However, the mineral binding ability was higher in CrPEEK than in the other two biomaterials. Although the coating improved the functional properties, NaOH coating did not influence the antibacterial effect against E. coli and S. aureus in these biomaterials. Similar to the antibacterial effects, the NaOH coating did not contribute any significant changes in cell proliferation and cell loading, and CrPEEK showed better biocompatibility among the biomaterials. Therefore, this study concluded that the surface modification of biomaterials could potentially improve the functional properties but not the antibacterial and biocompatibility, and CrPEEK could be an alternative material to Ti and Zr with desirable qualities in orthopedic applications.
Collapse
|
8
|
Advances in Multifunctional Bioactive Coatings for Metallic Bone Implants. MATERIALS (BASEL, SWITZERLAND) 2022; 16:183. [PMID: 36614523 PMCID: PMC9821663 DOI: 10.3390/ma16010183] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 12/19/2022] [Accepted: 12/21/2022] [Indexed: 06/17/2023]
Abstract
To fix the bone in orthopedics, it is almost always necessary to use implants. Metals provide the needed physical and mechanical properties for load-bearing applications. Although widely used as biomedical materials for the replacement of hard tissue, metallic implants still confront challenges, among which the foremost is their low biocompatibility. Some of them also suffer from excessive wear, low corrosion resistance, infections and shielding stress. To address these issues, various coatings have been applied to enhance their in vitro and in vivo performance. When merged with the beneficial properties of various bio-ceramic or polymer coatings remarkable bioactive, osteogenic, antibacterial, or biodegradable composite implants can be created. In this review, bioactive and high-performance coatings for metallic bone implants are systematically reviewed and their biocompatibility is discussed. Updates in coating materials and formulations for metallic implants, as well as their production routes, have been provided. The ways of improving the bioactive coating performance by incorporating bioactive moieties such as growth factors, osteogenic factors, immunomodulatory factors, antibiotics, or other drugs that are locally released in a controlled manner have also been addressed.
Collapse
|
9
|
Alloy Design and Fabrication of Duplex Titanium-Based Alloys by Spark Plasma Sintering for Biomedical Implant Applications. MATERIALS (BASEL, SWITZERLAND) 2022; 15:8562. [PMID: 36500058 PMCID: PMC9740822 DOI: 10.3390/ma15238562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 11/22/2022] [Accepted: 11/28/2022] [Indexed: 06/17/2023]
Abstract
Very often, pure Ti and (α + β) Ti-6Al-4V alloys have been used commercially for implant applications, but ensuring their chemical, mechanical, and biological biocompatibility is always a serious concern for sustaining the long-term efficacy of implants. Therefore, there has always been a great quest to explore new biomedical alloying systems that can offer substantial beneficial effects in tailoring a balance between the mechanical properties and biocompatibility of implantable medical devices. With a view to the mechanical performance, this study focused on designing a Ti-15Zr-2Ta-xSn (where x = 4, 6, 8) alloying system with high strength and low Young's modulus prepared by a powder metallurgy method. The experimental results showed that mechanical alloying, followed by spark plasma sintering, produced a fully consolidated (α + β) Ti-Zr-Ta-Sn-based alloy with a fine grain size and a relative density greater than 99%. Nevertheless, the shape, size, and distribution of α-phase precipitations were found to be sensitive to Sn contents. The addition of Sn also increased the α/β transus temperature of the alloy. For example, as the Sn content was increased from 4 wt.% to 8 wt.%, the β grains transformed into diverse morphological characteristics, namely, a thin-grain-boundary α phase (αGB), lamellar α colonies, and acicular αs precipitates and very low residual porosity during subsequent cooling after the spark plasma sintering procedure, which is consistent with the relative density results. Among the prepared alloys, Ti-15Zr-2Ta-8Sn exhibited the highest hardness (s340 HV), compressive yield strength (~1056 MPa), and maximum compressive strength (~1470). The formation of intriguing precipitate-matrix interfaces (α/β) acting as dislocation barriers is proposed to be the main reason for the high strength of the Ti-15Zr-2Ta-8Sn alloy. Finally, based on mechanical and structural properties, it is envisaged that our developed alloys will be promising for indwelling implant applications.
Collapse
|
10
|
To Study the Impact of Different Optimization Methods on Intensity-Modulated Radiotherapy and Volumetric-Modulated Arc Therapy Plans for Hip Prosthesis Patients. J Med Phys 2022; 47:262-269. [PMID: 36684696 PMCID: PMC9847001 DOI: 10.4103/jmp.jmp_14_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 05/12/2022] [Accepted: 05/26/2022] [Indexed: 11/11/2022] Open
Abstract
Purpose To study the impact of different optimization methods in dealing with metallic hip implant using intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) techniques. Materials and Methods A cohort of 16 patients having metallic implants was selected for the study. Three sets of IMRT and VMAT plans were generated. Set 1 IMRT (IM_Base), VMAT (VM_Base) without any restrictions on beam entry and exit, set 2 (IM_ENT and VM_ENT) optimizer restricts the beam entry and set 3 (IM_EXT+ENT), neither entry nor exit doses were allowed toward the metallic implant. Results There was no significant difference in target (D95%) and organ-at-risk doses between IM_Base and IM_ENT. There were significant (P = 0.002) improvements in planning target volume (PTV) V95% and homogeneity from IM_EXT+ENT to IM_ENT. There was no significant difference in plan quality between VM_Base and VM_ENT. There were significant (P = 0.005) improvements in PTV, V95%, homogeneity from VM_EXT+ENT to VM_ENT. V40Gy, V30Gy for bladder, rectum, bowel, and bowel maximum dose decreases significantly (P < 0.005) in IM_ENT compared to IM_EXT+ENT, but not significant for VMAT plans. Similarly, there was a significant decrease in dose spill outside target (P < 0.05) comparing 40%, 50%, 60%, and 70% dose spills for IM_ENT compared to IM_EXT+ENT, but variations among VMAT plans are insignificant. VMAT plans were always superior to IMRT plans for the same optimization methods. Conclusion The best approach is to plan hip prosthesis cases with blocked entry of radiation beam for IMRT and VMAT. The VMAT plans had more volumetric coverage, fewer hotspots, and lesser heterogeneity.
Collapse
|
11
|
Innovative High-Pressure Fabrication Processes for Porous Biomaterials-A Review. Bioengineering (Basel) 2021; 8:bioengineering8110170. [PMID: 34821736 PMCID: PMC8614988 DOI: 10.3390/bioengineering8110170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 10/25/2021] [Accepted: 10/28/2021] [Indexed: 11/17/2022] Open
Abstract
Biomaterials and their clinical application have become well known in recent years and progress in their manufacturing processes are essential steps in their technological advancement. Great advances have been made in the field of biomaterials, including ceramics, glasses, polymers, composites, glass-ceramics and metal alloys. Dense and porous ceramics have been widely used for various biomedical applications. Current applications of bioceramics include bone grafts, spinal fusion, bone repairs, bone fillers, maxillofacial reconstruction, etc. One of the common impediments in the bioceramics and metallic porous implants for biomedical applications are their lack of mechanical strength. High-pressure processing can be a viable solution in obtaining porous biomaterials. Many properties such as mechanical properties, non-toxicity, surface modification, degradation rate, biocompatibility, corrosion rate and scaffold design are taken into consideration. The current review focuses on different manufacturing processes used for bioceramics, polymers and metals and their alloys in porous forms. Recent advances in the manufacturing technologies of porous ceramics by freeze isostatic pressure and hydrothermal processing are discussed in detail. Pressure as a parameter can be helpful in obtaining porous forms for biomaterials with increased mechanical strength.
Collapse
|
12
|
Bioactive Ibuprofen-Loaded PLGA Coatings for Multifunctional Surface Modification of Medical Devices. Polymers (Basel) 2021; 13:polym13091413. [PMID: 33925498 PMCID: PMC8123841 DOI: 10.3390/polym13091413] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 04/22/2021] [Accepted: 04/24/2021] [Indexed: 12/16/2022] Open
Abstract
To modulate the biofunctionality of implantable medical devices commonly used in clinical practice, their surface modification with bioactive polymeric coatings is an attractive and successful emerging strategy. Biodegradable coatings based on poly(lactic acid-co-glycolic acid), PLGA, represent versatile and safe candidates for surface modification of implantable biomaterials and devices, providing additional tunable ability for topical delivery of desired therapeutic agents. In the present study, Ibuprofen-loaded PLGA coatings (PLGA/IBUP) were obtained by using the dip-coating and drop-casting combined protocol. The composite materials demonstrated long-term drug release under biologically simulated dynamic conditions. Reversible swelling phenomena of polymeric coatings occurred in the first two weeks of testing, accompanied by the gradual matrix degradation and slow release of the therapeutic agent. Irreversible degradation of PLGA coatings occurred after one month, due to copolymer's hydrolysis (evidenced by chemical and structural modifications). After 30 days of dynamic testing, the cumulative release of IBUP was ~250 µg/mL. Excellent cytocompatibility was revealed on human-derived macrophages, fibroblasts and keratinocytes. The results herein evidence the promising potential of PLGA/IBUP coatings to be used for surface modification of medical devices, such as metallic implants and wound dressings.
Collapse
|
13
|
Bioactive Coatings Based on Hydroxyapatite, Kanamycin, and Growth Factor for Biofilm Modulation. Antibiotics (Basel) 2021; 10:160. [PMID: 33562515 PMCID: PMC7914914 DOI: 10.3390/antibiotics10020160] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/22/2021] [Accepted: 02/02/2021] [Indexed: 02/07/2023] Open
Abstract
The occurrence of opportunistic local infections and improper integration of metallic implants results in severe health conditions. Protective and tunable coatings represent an attractive and challenging selection for improving the metallic devices' biofunctional performances to restore or replace bone tissue. Composite materials based on hydroxyapatite (HAp), Kanamycin (KAN), and fibroblast growth factor 2 (FGF2) are herein proposed as multifunctional coatings for hard tissue implants. The superior cytocompatibility of the obtained composite coatings was evidenced by performing proliferation and morphological assays on osteoblast cell cultures. The addition of FGF2 proved beneficial concerning the metabolic activity, adhesion, and spreading of cells. The KAN-embedded coatings exhibited significant inhibitory effects against bacterial biofilm development for at least two days, the results being superior in the case of Gram-positive pathogens. HAp-based coatings embedded with KAN and FGF2 protein are proposed as multifunctional materials with superior osseointegration potential and the ability to reduce device-associated infections.
Collapse
|
14
|
Processing of Highly Filled Polymer-Metal Feedstocks for Fused Filament Fabrication and the Production of Metallic Implants. MATERIALS 2020; 13:ma13194413. [PMID: 33022989 PMCID: PMC7579466 DOI: 10.3390/ma13194413] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 09/25/2020] [Accepted: 09/29/2020] [Indexed: 11/17/2022]
Abstract
Fused filament fabrication (FFF) is a new procedure for the production of plastic parts, particularly if the parts have a complex geometry and are only needed in a limited quantity, e.g., in specific medical applications. In addition to the production of parts which are purely composed of polymers, fused filament fabrication can be successfully applied for the preparation of green bodies for sintering of metallic implant materials in medical applications. In this case, highly filled polymer–metal feedstocks, which contain a variety of polymeric components, are used. In this study, we focus on various polymer-metal feedstocks, investigate the rheological properties of these materials, and relate them to our results of FFF experiments. Small amplitudes of shear oscillations reveal that the linear range of the polymer–metal feedstocks under investigation is very small, which is caused by elastic and viscous interactions between the metallic particles. These interactions strongly influence or even dominate the flow properties of the feedstock depending on the applied shear stress. The magnitude of the complex viscosity strongly increases with decreasing angular frequency, which indicates the existence of an apparent yield stress. The viscosity increase caused by the high powder loading needed for sintering limits the maximum printing velocity and the minimum layer height. The apparent yield stress hinders the formation of smooth surfaces in the FFF process and slows down the welding of deposited layers. The influence of composition on the processing parameters (suitable temperature range) and part properties (e.g., surface roughness) is discussed on the basis of rheological data.
Collapse
|
15
|
Diffusion tensor magnetic resonance imaging of the postoperative spine with metallic implants. NMR IN BIOMEDICINE 2020; 33:e4321. [PMID: 32348023 DOI: 10.1002/nbm.4321] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Revised: 04/14/2020] [Accepted: 04/14/2020] [Indexed: 06/11/2023]
Abstract
There has been a growing need to understand the mechanism of development of acute spinal cord injury (SCI) and to optimize treatment. The paramagnetic nature of metallic implants has hampered the application of diffusion tensor imaging (DTI) in postsurgical SCI monitoring. We describe here a successful implementation of spinal DTI in postsurgical SCI patients. Data were acquired using a single-shot turbo-spin-echo sequence, where an extra gradient is applied before the refocusing pulse train to eliminate contributions from the non-Carr-Purcell-Meiboom-Gill components following a diffusion preparation block where a single-spin echo scheme is deployed. The DTI images were acquired in axial orientation with a 2 x 2 x 4 mm3 resolution and a total of 18 slices. Diffusion gradients were applied in six directions with b values of 0 and 600 seconds/mm2 . The whole scan took ~10 minutes. The sequence was compared with SENSE-DW-EPI and ZOOM-DW-EPI on a phantom, eight patients with either anterior or posterior titanium alloy implants, and a pork loin with a similar implant. The protocol resulted in dramatically reduced geometric distortions compared with routine imaging sequences, however, the SNR efficiency was compromised. The spinal cord signal displacement was 0.68±1.00 mm (mean±SD, n = 8) for the proposed protocol, and 5.14±3.07 and 2.82±1.60 mm for the SENSE-DW-EPI and ZOOM-DW-EPI sequences, respectively. Fiber tracking was achieved in the presence of implants, which in one case was accompanied by central spinal cord caviation. Mathematical analysis concluded that the proposed protocol would be generally applicable in the spinal cord when the titanium alloy implant is ~15 mm away (<0.5 kHz B0 field drift). The protocol described is capable of DTI in postsurgery SCI patients with metallic implants at sufficient resolution and SNR.
Collapse
|
16
|
Abstract
We aimed to assess the usefulness of slice-encoding metal artifact correction (SEMAC) for the evaluation of spinal metallic implants and peripheral soft tissue lesions at 3T magnetic resonance.Twenty-seven patients with spinal metal implants underwent both SEMAC and high bandwidth (HiBW) based sequences scanning for reduction artifacts. The area size and maximum longitude of artifacts, the peri-prosthetic soft tissue, and metal visualization were assessed by 2 independent doctors, as well as the lesions signs were reviewed by 2 senior readers. A paired 2-tailed t-test and McNemar test were used for statistical analysis.The size of artifacts on SEMAC images decreased by 37% and 24%, and the scores are higher than that on HiBW images. T1 weighted (T1W)-SEMAC acquired the highest score in metal prosthesis visualization, while short tau inversion recovery SEMAC showed more signs of lesions than clinical HiBW group.SEMAC effectively reduces the metal artifacts and is useful for assessing soft tissue lesions.
Collapse
|
17
|
Editorial: Enabling Biomaterials for New Biomedical Technologies and Clinical Therapies. Front Bioeng Biotechnol 2020; 8:559. [PMID: 32582676 PMCID: PMC7289920 DOI: 10.3389/fbioe.2020.00559] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 05/11/2020] [Indexed: 12/04/2022] Open
|
18
|
Improvement of osseointegration by recruiting stem cells to titanium implants fabricated with 3D printing. Ann N Y Acad Sci 2019; 1463:37-44. [PMID: 31603258 DOI: 10.1111/nyas.14251] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 08/25/2019] [Accepted: 09/16/2019] [Indexed: 01/14/2023]
Abstract
Slow and incomplete osseointegration and loss of osseointegration are major problems in dental and bone implants. We designed implants with interconnected 3D-tubulous structures and hypothesized that such interconnecting 3D (I3D) structures would serve as a repository for chemoattractants to recruit stem cells to promote osseointegration. A concept Laser Mlab-cusing-R laser-powder-bed-fusion (LPBF) 3D printing system was used to produce titanium implants with designed features. The implants were loaded (coated) with stromal cell-derived factor-1 alpha (SDF-1α), and subjected to stem cell recruitment. Implants were then surgically transplanted into the rabbit skull bone. After 12 weeks, osseointegration was analyzed by reverse-torque test and the implants were examined for calcium deposition by Alizarin Red staining. The I3D implants attracted significantly more stem cells than solid implants when coated (loaded) with SDF-1α. Greater torque force was needed to extract the I3D implants with 200 and 300 µm I3D structures than to extract solid implants from the skull. Generally, more calcium deposition was observed on the I3D implants than on the solid counterparts. LPBF 3D printing can be used to fabricate implants with complex structures. I3D-tubulous structures of implants can retain chemoattractant for recruitment of stem cells to enhance osseointegration.
Collapse
|
19
|
Accelerated three-dimensional multispectral MRI with robust principal component analysis for separation of on- and off-resonance signals. Magn Reson Med 2018; 79:1495-1505. [PMID: 28686800 PMCID: PMC5756705 DOI: 10.1002/mrm.26819] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Revised: 05/19/2017] [Accepted: 06/12/2017] [Indexed: 01/24/2023]
Abstract
PURPOSE To enable highly accelerated distortion-free MRI near metal by separating on- and off-resonance to exploit the redundancy of slice-phase encoding for the dominant on-resonance component. METHODS Multispectral MRI techniques resolve off-resonance distortions by a combination of limited excitation bins and additional encoding. Inspired by robust principal component analysis, a novel compact representation of multispectral images as a sum of rank-one and sparse matrices corresponding to on- and off-resonance respectively is described. This representation is used in a calibration-free and model-free reconstruction for data with an undersampling pattern that varies between bins. Retrospective undersampling was used to compare the proposed reconstruction and bin-by-bin compressed sensing. Hip images were acquired in eight patients with standard and prospectively undersampled three-dimensional multispectral imaging, and image quality was evaluated by two radiologists on a 5-point scale. RESULTS Experiments with retrospective undersampling showed that the enhanced sparsity afforded by the separation greatly reduces reconstruction errors and artifacts. Images from prospectively undersampled multispectral imaging offered 2.6-3.4-fold (18-24-fold overall) acceleration compared to standard multispectral imaging with parallel imaging and partial-Fourier acceleration with equivalence in all qualitative assessments within a tolerance of one point (P < 0.004). CONCLUSION Three-dimensional multispectral imaging can be highly accelerated by varying undersampling between bins and separating on- and off-resonance. Magn Reson Med 79:1495-1505, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
|
20
|
Artifact-reduced imaging of biopsy needles with 2D multispectral imaging. Magn Reson Med 2017; 80:655-661. [PMID: 29285787 DOI: 10.1002/mrm.27056] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Revised: 11/30/2017] [Accepted: 12/01/2017] [Indexed: 12/28/2022]
Abstract
PURPOSE Magnetic resonance (MR) guidance for biopsy procedures requires high intrinsic soft-tissue contrast. However, artifacts induced by the metallic needle can reduce its localization and require low-susceptibility needle materials with poorer cutting performance. In a proof of concept, we demonstrate the feasibility of 2D multispectral imaging (2DMSI) for both needle tracking and for needle artifact reduction for more precise needle localization and to enable the usage of needle materials with higher susceptibility. METHOD We applied 2DMSI for imaging of MR-compatible biopsy needles, conventional stainless-steel needles, and mixed-material needles and compared it to conventional techniques. In addition, we exploited intrinsic off-resonance information for passive needle tracking. RESULTS 2DMSI achieved a stronger reduction of the needle artifact compared to conventional techniques. For the mixed-material needles, the artifact was reduced to a level below that for MR-compatible needles with conventional imaging. The passive tracking also improved the ability to pinpoint the needle. CONCLUSION 2DMSI is promising for both needle tracking and artifact-reduced imaging of biopsy needles for a more precise needle localization. 2DMSI may be particularly promising for needles inducing large distortions or for targeting of small lesions. In addition, it may enable the use of needle materials with higher susceptibility and potentially better sampling performance. Magn Reson Med 80:655-661, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
|
21
|
MRI monitoring of focused ultrasound sonications near metallic hardware. Magn Reson Med 2017; 80:259-271. [PMID: 29215150 DOI: 10.1002/mrm.27034] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Revised: 11/13/2017] [Accepted: 11/14/2017] [Indexed: 01/06/2023]
Abstract
PURPOSE To explore the temperature-induced signal change in two-dimensional multi-spectral imaging (2DMSI) for fast thermometry near metallic hardware to enable MR-guided focused ultrasound surgery (MRgFUS) in patients with implanted metallic hardware. METHOD 2DMSI was optimized for temperature sensitivity and applied to monitor focus ultrasound surgery (FUS) sonications near metallic hardware in phantoms and ex vivo porcine muscle tissue. Further, we evaluated its temperature sensitivity for in vivo muscle in patients without metallic hardware. In addition, we performed a comparison of temperature sensitivity between 2DMSI and conventional proton-resonance-frequency-shift (PRFS) thermometry at different distances from metal devices and different signal-to-noise ratios (SNR). RESULTS 2DMSI thermometry enabled visualization of short ultrasound sonications near metallic hardware. Calibration using in vivo muscle yielded a constant temperature sensitivity for temperatures below 43 °C. For an off-resonance coverage of ± 6 kHz, we achieved a temperature sensitivity of 1.45%/K, resulting in a minimum detectable temperature change of ∼2.5 K for an SNR of 100 with a temporal resolution of 6 s per frame. CONCLUSION The proposed 2DMSI thermometry has the potential to allow MR-guided FUS treatments of patients with metallic hardware and therefore expand its reach to a larger patient population. Magn Reson Med 80:259-271, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
|
22
|
Improved electrochemical performance of nitrocarburised stainless steel by hydrogenated amorphous carbon thin films for bone tissue engineering. IET Nanobiotechnol 2017; 11:656-660. [PMCID: PMC8676089 DOI: 10.1049/iet-nbt.2016.0163] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2016] [Revised: 12/15/2016] [Accepted: 01/17/2017] [Indexed: 08/29/2023] Open
Abstract
In this study, hydrogenated amorphous carbon thin films, structurally similar to diamond‐like carbon (DLC), were deposited on the surface of untreated and plasma nitrocarburised (Nitrocarburizing‐treated) stainless steel medical implants using a plasma‐enhanced chemical vapour deposition method. The deposited DLC thin films on the nitrocarburising‐treated implants (CN+DLC) exhibited an appropriate adhesion to the substrates. The results clearly indicated that the applied DLC thin films showed excellent pitting and corrosion resistance with no considerable damage on the surface in comparison with the other samples. The CN+DLC thin films could be considered as an efficient approach for improving the biocompatibility and chemical inertness of metallic implants.
Collapse
|
23
|
Sparse-SEMAC: rapid and improved SEMAC metal implant imaging using SPARSE-SENSE acceleration. Magn Reson Med 2016; 78:79-87. [PMID: 27454003 DOI: 10.1002/mrm.26342] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2015] [Revised: 05/27/2016] [Accepted: 06/21/2016] [Indexed: 02/03/2023]
Abstract
PURPOSE To develop an accelerated SEMAC metal implant MRI technique (Sparse-SEMAC) with reduced scan time and improved metal distortion correction. METHODS Sparse-SEMAC jointly exploits the inherent sparsity along the additional phase-encoding dimension and multicoil encoding capabilities to significantly accelerate data acquisition. A prototype pulse sequence with pseudorandom ky -kz undersampling and an inline image reconstruction was developed for integration in clinical studies. Three patients with hip implants were imaged using the proposed Sparse-SEMAC with eight-fold acceleration and compared with the standard-SEMAC technique used in clinical studies (three-fold GRAPPA acceleration). Measurements were performed with SEMAC-encoding steps (SES) = 15 for Sparse-SEMAC and SES = 9 for Standard-SEMAC using high spatial resolution Proton Density (PD) and lower-resolution STIR acquisitions. Two expert musculoskeletal (MSK) radiologists performed a consensus reading to score image-quality parameters. RESULTS Sparse-SEMAC enables up to eight-fold acceleration of data acquisition that results in two-fold scan time reductions, compared with Standard-SEMAC, with improved metal artifact correction for patients with hip implants without degrading spatial resolution. CONCLUSION The high acceleration enabled by Sparse-SEMAC would enable clinically feasible examination times with improved correction of metal distortion. Magn Reson Med 78:79-87, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
|
24
|
Effect of Extreme Wettability on Platelet Adhesion on Metallic Implants: From Superhydrophilicity to Superhydrophobicity. ACS APPLIED MATERIALS & INTERFACES 2016; 8:17631-17641. [PMID: 27322889 DOI: 10.1021/acsami.6b03644] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In order to design antithrombotic implants, the effect of extreme wettability (superhydrophilicity to superhydrophobicity) on the biocompatibility of the metallic substrates (stainless steel and titanium) was investigated. The wettability of the surface was altered by chemical treatments and laser ablation methods. The chemical treatments generated different functionality groups and chemical composition as evident from XPS analysis. The micro/nanopatterning by laser ablation resulted in three different pattern geometry and different surface roughness and consequently wettability. The patterned surface were further modified with chemical treatments to generate a wide range of surface wettability. The influence of chemical functional groups, pattern geometry, and surface wettability on protein adsorption and platelet adhesion was studied. On chemically treated flat surfaces, the type of hydrophilic treatment was shown to be a contributing factor that determines the platelet adhesion, since the hydrophilic oxidized substrates exhibit less platelet adhesion in comparison to the control untreated or acid treated surfaces. Also, the surface morphology, surface roughness, and superhydrophobic character of the surfaces are contributing factors to platelet adhesion on the surface. Our results show that superhydrophobic cauliflower-like patterns are highly resistant to platelet adhesion possibly due to the stability of Cassie-Baxter state for this pattern compared to others. Our results also show that simple surface treatments on metals offer a novel way to improve the hemocompatibility of metallic substrates.
Collapse
|
25
|
MR thermometry near metallic devices using multispectral imaging. Magn Reson Med 2016; 77:1162-1169. [PMID: 26991803 DOI: 10.1002/mrm.26203] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Revised: 01/27/2016] [Accepted: 02/16/2016] [Indexed: 11/07/2022]
Abstract
PURPOSE The lack of a technique for MR thermometry near metal excludes a growing patient population from promising treatments such as MR-guided focused ultrasound therapy. Here we explore the feasibility of multispectral imaging (MSI) for noninvasive temperature measurement in the presence of strong field inhomogeneities by exploiting the temperature dependency of the T1 relaxation time. METHODS A two-dimensional inversion-recovery-prepared MSI pulse sequence (2DMSI) was implemented for artifact-reduced T1 mapping near metal. A series of T1 maps was acquired in a metallic implant phantom while increasing the phantom temperature. The measured change in T1 was analyzed with respect to the phantom temperature. For comparison, proton resonance frequency shift (PRFS) thermometry was performed. RESULTS 2DMSI achieved artifact-reduced, single-slice T1 mapping in the presence of strong off-resonance with a spatial resolution of 1.9 mm in-plane and a temporal resolution of 5 min. The maps enabled temperature measurements over a range of 30°C with an uncertainty below 1.4°C. The quality of the resulting temperature maps was independent of the distance from the metal, whereas the PRFS-based temperature measurements were increasingly impaired with increasing off-resonance. CONCLUSION We demonstrated the ability to noninvasively measure temperature near metal using MSI and the T1 temperature sensitivity. Magn Reson Med 77:1162-1169, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
|
26
|
Characterizing the limits of MRI near metallic prostheses. Magn Reson Med 2014; 74:1564-73. [PMID: 25483410 DOI: 10.1002/mrm.25540] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Revised: 10/22/2014] [Accepted: 10/27/2014] [Indexed: 12/11/2022]
Abstract
PURPOSE To characterize the fundamental limits of MRI near metallic implants on RF excitation, frequency encoding, and chemical shift-encoding water-fat separation. METHODS Multicomponent three-dimensional (3D) digital models of a total hip and a total knee replacement were used to construct material-specific susceptibility maps. The fundamental limits and spatial relationship of imaging near metallic prostheses were investigated as a function of distance from the prosthetic surface by calculating 3D field map perturbations using a well-validated k-space based dipole kernel. RESULTS Regions limited by the bandwidth of RF excitation overlap substantially with those fundamentally limited by frequency encoding. Rapid breakdown of water-fat separation occurs once the intravoxel off-resonance exceeds ∼6 ppm over a full range of fat fractions (0%-100%) and SNR (5-100). CONCLUSION Current 3D multispectral imaging methods would not benefit greatly from exciting spins beyond ±12 kHz despite the presence of signal that lies outside of this range from tissue directly adjacent to the metallic implants. Methods such as phase encoding in all three spatial dimensions are necessary to spatially resolve spins beyond an excitation bandwidth of ±12 kHz. The approach described in this study provides a benchmark for the capabilities of current imaging techniques to guide development of new MRI methods for imaging near metal.
Collapse
|
27
|
Nanostructured biointerfacing of metals with carbon nanotube/chitosan hybrids by electrodeposition for cell stimulation and therapeutics delivery. ACS APPLIED MATERIALS & INTERFACES 2014; 6:20214-24. [PMID: 25325144 DOI: 10.1021/am505759p] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Exploring the biological interfaces of metallic implants has been an important issue in achieving biofunctional success. Here we develop a biointerface with nanotopological features and bioactive composition, comprising a carbon nanotube (CNT) and chitosan (Chi) hybrid, via an electrophoretic deposition (EPD). The physicochemical properties, in vitro biocompatibility, and protein delivering capacity of the decorated nanohybrid layer were investigated, to address its potential usefulness as bone regenerating implants. Over a wide compositional range, the nanostructured hybrid interfaces were successfully formed with varying thicknesses, depending on the electrodeposition parameters. CNT-Chi hybrid interfaces showed a time-sequenced degradation in saline water, and a rapid induction of hydroxyapatite mineral in a simulated body fluid. The nanostructured hybrid substrates stimulated the initial adhesion events of the osteoblastic cells, including cell adhesion rate, spreading behaviors, and expression of adhesive proteins. The nanostructured hybrid interfaces significantly improved the adsorption of protein molecules, which was enabled by the surface charge interaction, and increased surface area of the nanotopology. Furthermore, the incorporated protein was released at a highly sustained rate, profiling a diffusion-controlled pattern over a couple of weeks, suggesting the possible usefulness as a protein delivery device. Collectively, the nanostructured hybrid CNT-Chi layer, implemented by an electrodeposition, is considered a biocompatible, cell-stimulating, and protein-delivering biointerface of metallic implants.
Collapse
|
28
|
Superposition of nanostructures on microrough titanium-aluminum-vanadium alloy surfaces results in an altered integrin expression profile in osteoblasts. Connect Tissue Res 2014; 55 Suppl 1:164-8. [PMID: 25158204 PMCID: PMC4287400 DOI: 10.3109/03008207.2014.923881] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Recent studies of new surface modifications that superimpose well-defined nanostructures on microrough implants, thereby mimicking the hierarchical complexity of native bone, report synergistically enhanced osteoblast maturation and local factor production at the protein level compared to growth on surfaces that are smooth, nanorough, or microrough. Whether the complex micro/nanorough surfaces enhance the osteogenic response by triggering similar patterns of integrin receptors and their associated signaling pathways as with well-established microrough surfaces, is not well understood. Human osteoblasts (hOBs) were cultured until confluent for gene expression studies on tissue culture polystyrene (TCPS) or on titanium alloy (Ti6Al4V) disks with different surface topographies: smooth, nanorough, microrough, and micro/nanorough surfaces. mRNA expression of osteogenesis-related markers such as osteocalcin (BGLAP) and bone sialoprotein (BSP), bone morphogenetic protein 2 (BMP2), BMP4, noggin (NOG) and gremlin 1 (GREM1) were all higher on microrough and micro/nanorough surfaces, with few differences between them, compared to smooth and nanorough groups. Interestingly, expression of integrins α1 and α2, which interact primarily with collagens and laminin and have been commonly associated with osteoblast differentiation on microrough Ti and Ti6Al4V, were expressed at lower levels on micro/nanorough surfaces compared to microrough ones. Conversely, the αv subunit, which binds ligands such as vitronectin, osteopontin, and bone sialoprotein among others, had higher expression on micro/nanorough surfaces concomitantly with regulation of the β3 mRNA levels on nanomodified surfaces. These results suggest that the maturation of osteoblasts on micro/nanorough surfaces may be occurring through different integrin engagement than those established for microrough-only surfaces.
Collapse
|
29
|
Significant RF-EMF and thermal levels observed in a computational model of a person with a tibial plate for grounded 40 MHz exposure. Bioelectromagnetics 2014; 35:284-95. [PMID: 24578303 DOI: 10.1002/bem.21846] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2013] [Accepted: 01/20/2014] [Indexed: 11/05/2022]
Abstract
Using numerical modeling, a worst-case scenario is considered when a person with a metallic implant is exposed to a radiofrequency (RF) electromagnetic field (EMF). An adult male standing on a conductive ground plane was exposed to a 40 MHz vertically polarized plane wave field, close to whole-body resonance where maximal induced current flows are expected in the legs. A metal plate (50-300 mm long) was attached to the tibia in the left leg. The findings from this study re-emphasize the need to ensure compliance with limb current reference levels for exposures near whole-body resonance, and not just rely on compliance with ambient electric (E) and magnetic (H) field reference levels. Moreover, we emphasize this recommendation for someone with a tibial plate, as failure to comply may result in significant tissue damage (increases in the localized temperature of 5-10 °C were suggested by the modeling for an incident E-field of 61.4 V/m root mean square (rms)). It was determined that the occupational reference level for limb current (100 mA rms), as stipulated in the 1998 guidelines of the International Commission on Non-Ionizing Radiation Protection (ICNIRP), is satisfied if the plane wave incident E-field levels are no more than 29.8 V/m rms without an implant and 23.4 V/m rms for the model with a 300 mm implant.
Collapse
|
30
|
Hexagonal undersampling for faster MRI near metallic implants. Magn Reson Med 2014; 73:662-8. [PMID: 24549782 DOI: 10.1002/mrm.25132] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2013] [Revised: 12/20/2013] [Accepted: 12/21/2013] [Indexed: 12/22/2022]
Abstract
PURPOSE Slice encoding for metal artifact correction acquires a three-dimensional image of each excited slice with view-angle tilting to reduce slice and readout direction artifacts respectively, but requires additional imaging time. The purpose of this study was to provide a technique for faster imaging around metallic implants by undersampling k-space. METHODS Assuming that areas of slice distortion are localized, hexagonal sampling can reduce imaging time by 50% compared with conventional scans. This work demonstrates this technique by comparisons of fully sampled images with undersampled images, either from simulations from fully acquired data or from data actually undersampled during acquisition, in patients and phantoms. Hexagonal sampling is also shown to be compatible with parallel imaging and partial Fourier acquisitions. Image quality was evaluated using a structural similarity (SSIM) index. RESULTS Images acquired with hexagonal undersampling had no visible difference in artifact suppression from fully sampled images. The SSIM index indicated high similarity to fully sampled images in all cases. CONCLUSION The study demonstrates the ability to reduce scan time by undersampling without compromising image quality.
Collapse
|
31
|
Compressed-sensing multispectral imaging of the postoperative spine. J Magn Reson Imaging 2013; 37:243-8. [PMID: 22791572 PMCID: PMC3473176 DOI: 10.1002/jmri.23750] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2012] [Accepted: 06/05/2012] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To apply compressed sensing (CS) to in vivo multispectral imaging (MSI), which uses additional encoding to avoid magnetic resonance imaging (MRI) artifacts near metal, and demonstrate the feasibility of CS-MSI in postoperative spinal imaging. MATERIALS AND METHODS Thirteen subjects referred for spinal MRI were examined using T2-weighted MSI. A CS undersampling factor was first determined using a structural similarity index as a metric for image quality. Next, these fully sampled datasets were retrospectively undersampled using a variable-density random sampling scheme and reconstructed using an iterative soft-thresholding method. The fully and undersampled images were compared using a 5-point scale. Prospectively undersampled CS-MSI data were also acquired from two subjects to ensure that the prospective random sampling did not affect the image quality. RESULTS A two-fold outer reduction factor was deemed feasible for the spinal datasets. CS-MSI images were shown to be equivalent or better than the original MSI images in all categories: nerve visualization: P = 0.00018; image artifact: P = 0.00031; image quality: P = 0.0030. No alteration of image quality and T2 contrast was observed from prospectively undersampled CS-MSI. CONCLUSION This study shows that the inherently sparse nature of MSI data allows modest undersampling followed by CS reconstruction with no loss of diagnostic quality.
Collapse
|
32
|
Tribocorrosion behavior of CoCrMo alloy for hip prosthesis as a function of loads: a comparison between two testing systems. WEAR : AN INTERNATIONAL JOURNAL ON THE SCIENCE AND TECHNOLOGY OF FRICTION LUBRICATION AND WEAR 2011; 271:1210-1219. [PMID: 21921971 PMCID: PMC3171172 DOI: 10.1016/j.wear.2011.01.086] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Metal-on-metal (MOM) hip prosthesis bearings have enjoyed renewed popularity, but concerns remain with wear debris and metal ion release causing a negative response in the surrounding tissues. Further understanding into the wear and corrosion mechanisms occurring in MOM hips is therefore essential.The purpose of this study was to evaluate the tribocorrosion behaviour, or interplay between corrosion and wear, of a low-carbon CoCrMo alloy as a function of loading. The tribocorrosion tests were performed using two tribometer configurations. In the first configuration, "System A", a linearly reciprocating alumina ball slid against the flat metal immersed in a phosphate buffer solution (PBS). In the second configuration, "System B", the flat end of a cylindrical metal pin was pressed against an alumina ball that oscillated rotationally, using bovine calf serum (BCS) as the lubricant and electrolyte. System B was custom-built to emulate in vivo conditions. The tribocorrosion tests were performed under potentiostatic conditions at -0.345V, with a sliding duration of 1800 seconds and a frequency of 1Hz. In System A the applied loads were 0.05, 0.5, and 1N (138, 296 and 373MPa, respectively) and in System B were 16, 32, and 64N (474, 597, and 752MPa, respectively). Electrochemical impedance spectroscopy (EIS) and polarization resistance were estimated. The total mass loss (K(wc)) in the CoCrMo was determined. The mass loss due to wear (K(w)) and that due to corrosion (K(c)) were determined. The dominant wear regime for the CoCrMo alloy subjected to sliding changes from wear-corrosion to mechanical wear as the contact stress increases. An attempt was made to compare both system, in their tribochemical responses and formulate some insights in the total degradation processes. Our results also suggest that the proteins in the serum lubricant assist in the generation of a protective layer against corrosion during sliding. The study highlights the need of adequate methodology/guidelines to compare the results from different test systems and translating in solving the practical problems.
Collapse
|