601
|
Singam NV, Dwivedi A, Espay AJ. Writing Orthotic Device for the Management of Writer's Cramp. Front Neurol 2013; 4:2. [PMID: 23372563 PMCID: PMC3556565 DOI: 10.3389/fneur.2013.00002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2012] [Accepted: 01/07/2013] [Indexed: 11/21/2022] Open
Abstract
Background: Oral therapies and chemodenervation procedures are often unrewarding in the treatment of focal, task-specific hand disorders such as writer’s cramp or primary writing tremor (PWT). Methods: A portable writing orthotic device (WOD) was evaluated on 15 consecutively recruited writer’s cramp and PWT subjects. We measured overall impairment at baseline and after 2 weeks of at-home use with the Writer’s Cramp Rating Scale (range = 0–8, higher is worse) and writing quality and comfort with a visual analog scale (range = 0–10). Results: Compared to regular pen, the WOD improved the Writer’s Cramp Rating Scale scores at first-test (p = 0.001) and re-test (p = 0.005) as well as writing quality and device comfort in writer’s cramp subjects. Benefits were sustained at 2 weeks. PWT subjects demonstrated no improvements. Conclusion: WODs exploiting a muscle-substitution strategy may yield immediate benefits in patients with writer’s cramp.
Collapse
|
602
|
Abstract
BACKGROUND Recent problems with medical devices have highlighted the need for improved surveillance. New procedures are largely unregulated. SOURCES OF DATA Information from regulators. Guidance produced by the National Institute for Health and Care Excellence Interventional Procedures and Medical Technologies Advisory Committees and the evidence used in their evaluations. AREAS OF AGREEMENT More and better evidence is required for new medical devices and procedures when they are introduced into practice. Routine collection of observational data on outcomes should be improved. AREAS OF CONTROVERSY How best to protect patients from harm while allowing rapid access to potentially beneficial interventions. GROWING POINTS Establishing systems for good data collection on the use of devices and procedures. AREAS TIMELY FOR DEVELOPING RESEARCH How to accrue more and better evidence about devices and procedures through clinical trials and various avenues of observational data collection.
Collapse
|
603
|
Abstract
OBJECTIVE Minimal clinical research has investigated the significance of different blood pressure monitoring techniques in the ICU and whether systolic vs. mean blood pressures should be targeted in therapeutic protocols and in defining clinical study cohorts. The objectives of this study are to compare real-world invasive arterial blood pressure with noninvasive blood pressure, and to determine if differences between the two techniques have clinical implications. DESIGN We conducted a retrospective study comparing invasive arterial blood pressure and noninvasive blood pressure measurements using a large ICU database. We performed pairwise comparison between concurrent measures of invasive arterial blood pressure and noninvasive blood pressure. We studied the association of systolic and mean invasive arterial blood pressure and noninvasive blood pressure with acute kidney injury, and with ICU mortality. SETTING Adult intensive care units at a tertiary care hospital. PATIENTS Adult patients admitted to intensive care units between 2001 and 2007. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS Pairwise analysis of 27,022 simultaneously measured invasive arterial blood pressure/noninvasive blood pressure pairs indicated that noninvasive blood pressure overestimated systolic invasive arterial blood pressure during hypotension. Analysis of acute kidney injury and ICU mortality involved 1,633 and 4,957 patients, respectively. Our results indicated that hypotensive systolic noninvasive blood pressure readings were associated with a higher acute kidney injury prevalence (p = 0.008) and ICU mortality (p < 0.001) than systolic invasive arterial blood pressure in the same range (≤70 mm Hg). Noninvasive blood pressure and invasive arterial blood pressure mean arterial pressures showed better agreement; acute kidney injury prevalence (p = 0.28) and ICU mortality (p = 0.76) associated with hypotensive mean arterial pressure readings (≤60 mm Hg) were independent of measurement technique. CONCLUSIONS Clinically significant discrepancies exist between invasive and noninvasive systolic blood pressure measurements during hypotension. Mean blood pressure from both techniques may be interpreted in a consistent manner in assessing patients' prognosis. Our results suggest that mean rather than systolic blood pressure is the preferred metric in the ICU to guide therapy.
Collapse
|
604
|
Govoni L, Dellaca' RL, Peñuelas O, Bellani G, Artigas A, Ferrer M, Navajas D, Pedotti A, Farré R. Actual performance of mechanical ventilators in ICU: a multicentric quality control study. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2012; 5:111-9. [PMID: 23293543 PMCID: PMC3534536 DOI: 10.2147/mder.s35864] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Even if the performance of a given ventilator has been evaluated in the laboratory under very well controlled conditions, inappropriate maintenance and lack of long-term stability and accuracy of the ventilator sensors may lead to ventilation errors in actual clinical practice. The aim of this study was to evaluate the actual performances of ventilators during clinical routines. A resistance (7.69 cmH2O/L/s) – elastance (100 mL/cmH2O) test lung equipped with pressure, flow, and oxygen concentration sensors was connected to the Y-piece of all the mechanical ventilators available for patients in four intensive care units (ICUs; n = 66). Ventilators were set to volume-controlled ventilation with tidal volume = 600 mL, respiratory rate = 20 breaths/minute, positive end-expiratory pressure (PEEP) = 8 cmH2O, and oxygen fraction = 0.5. The signals from the sensors were recorded to compute the ventilation parameters. The average ± standard deviation and range (min–max) of the ventilatory parameters were the following: inspired tidal volume = 607 ± 36 (530–723) mL, expired tidal volume = 608 ± 36 (530–728) mL, peak pressure = 20.8 ± 2.3 (17.2–25.9) cmH2O, respiratory rate = 20.09 ± 0.35 (19.5–21.6) breaths/minute, PEEP = 8.43 ± 0.57 (7.26–10.8) cmH2O, oxygen fraction = 0.49 ± 0.014 (0.41–0.53). The more error-prone parameters were the ones related to the measure of flow. In several cases, the actual delivered mechanical ventilation was considerably different from the set one, suggesting the need for improving quality control procedures for these machines.
Collapse
|
605
|
Modolo J, Beuter A, Thomas AW, Legros A. Using "smart stimulators" to treat Parkinson's disease: re-engineering neurostimulation devices. Front Comput Neurosci 2012; 6:69. [PMID: 23060781 PMCID: PMC3448062 DOI: 10.3389/fncom.2012.00069] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2012] [Accepted: 08/29/2012] [Indexed: 11/13/2022] Open
Abstract
Let's imagine the cruise control of your car locked at 120 km/h on any road in any condition (city, country, highway, sunny or rainy weather), or your car air conditioner set on maximum cold in any temperature condition (even during a snowy winter): would you find it efficient? That would probably not be the most optimal strategy for a proper and comfortable driving experience. As surprising as this may seem, this is a pretty accurate illustration of how deep brain stimulation is used today to treat Parkinson's disease motor symptoms and other neurological disorders such as essential tremor, obsessive-compulsive disorder, or epilepsy.
Collapse
|
606
|
Brunoni AR, Nitsche MA, Bolognini N, Bikson M, Wagner T, Merabet L, Edwards DJ, Valero-Cabre A, Rotenberg A, Pascual-Leone A, Ferrucci R, Priori A, Boggio PS, Fregni F. Clinical research with transcranial direct current stimulation (tDCS): challenges and future directions. Brain Stimul 2012; 5:175-195. [PMID: 22037126 PMCID: PMC3270156 DOI: 10.1016/j.brs.2011.03.002] [Citation(s) in RCA: 885] [Impact Index Per Article: 73.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2010] [Revised: 01/25/2011] [Accepted: 03/03/2011] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Transcranial direct current stimulation (tDCS) is a neuromodulatory technique that delivers low-intensity, direct current to cortical areas facilitating or inhibiting spontaneous neuronal activity. In the past 10 years, tDCS physiologic mechanisms of action have been intensively investigated giving support for the investigation of its applications in clinical neuropsychiatry and rehabilitation. However, new methodologic, ethical, and regulatory issues emerge when translating the findings of preclinical and phase I studies into phase II and III clinical studies. The aim of this comprehensive review is to discuss the key challenges of this process and possible methods to address them. METHODS We convened a workgroup of researchers in the field to review, discuss, and provide updates and key challenges of tDCS use in clinical research. MAIN FINDINGS/DISCUSSION We reviewed several basic and clinical studies in the field and identified potential limitations, taking into account the particularities of the technique. We review and discuss the findings into four topics: (1) mechanisms of action of tDCS, parameters of use and computer-based human brain modeling investigating electric current fields and magnitude induced by tDCS; (2) methodologic aspects related to the clinical research of tDCS as divided according to study phase (ie, preclinical, phase I, phase II, and phase III studies); (3) ethical and regulatory concerns; and (4) future directions regarding novel approaches, novel devices, and future studies involving tDCS. Finally, we propose some alternative methods to facilitate clinical research on tDCS.
Collapse
|
607
|
Muskovich M, Bettinger CJ. Biomaterials-based electronics: polymers and interfaces for biology and medicine. Adv Healthc Mater 2012; 1:248-66. [PMID: 23184740 PMCID: PMC3642371 DOI: 10.1002/adhm.201200071] [Citation(s) in RCA: 90] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2012] [Indexed: 12/18/2022]
Abstract
Advanced polymeric biomaterials continue to serve as a cornerstone for new medical technologies and therapies. The vast majority of these materials, both natural and synthetic, interact with biological matter in the absence of direct electronic communication. However, biological systems have evolved to synthesize and utilize naturally-derived materials for the generation and modulation of electrical potentials, voltage gradients, and ion flows. Bioelectric phenomena can be translated into potent signaling cues for intra- and inter-cellular communication. These cues can serve as a gateway to link synthetic devices with biological systems. This progress report will provide an update on advances in the application of electronically active biomaterials for use in organic electronics and bio-interfaces. Specific focus will be granted to covering technologies where natural and synthetic biological materials serve as integral components such as thin film electronics, in vitro cell culture models, and implantable medical devices. Future perspectives and emerging challenges will also be highlighted.
Collapse
|
608
|
Carayon P, Bass E, Bellandi T, Gurses A, Hallbeck S, Mollo V. Socio-Technical Systems Analysis in Health Care: A Research Agenda. IIE TRANSACTIONS ON HEALTHCARE SYSTEMS ENGINEERING 2011; 1:145-160. [PMID: 22611480 PMCID: PMC3351758 DOI: 10.1080/19488300.2011.619158] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
Abstract
Given the complexity of health care and the 'people' nature of healthcare work and delivery, STSA (Sociotechnical Systems Analysis) research is needed to address the numerous quality of care problems observed across the world. This paper describes open STSA research areas, including workload management, physical, cognitive and macroergonomic issues of medical devices and health information technologies, STSA in transitions of care, STSA of patient-centered care, risk management and patient safety management, resilience, and feedback loops between event detection, reporting and analysis and system redesign.
Collapse
|
609
|
Olsen BS, Lilleøre SK, Korsholm CN, Kracht T. Novopen Echo® for the delivery of insulin: a comparison of usability, functionality and preference among pediatric subjects, their parents, and health care professionals. J Diabetes Sci Technol 2010; 4:1468-75. [PMID: 21129343 PMCID: PMC3005058 DOI: 10.1177/193229681000400622] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Despite advances in insulin pen design and functionality, the selection of pens available for children with diabetes is limited. This study assessed the usability, functionality and attitudes towards NovoPen Echo®, a new durable insulin pen designed for pediatric patients that combines a simple memory function with half-increment dosing, versus NovoPen® Junior and HumaPen® Luxura™ HD in pediatric subjects, their parents, and health care professionals (HCPs). METHODS Pens were evaluated in random order during 1:1 interviews in the three target groups (pediatric subjects, parents, and HCPs) in Germany, France, and Canada. Study participants were asked to prepare each pen, perform injections into foam cushions, and provide feedback via a standardized questionnaire. RESULTS In total, 205 participants were included in the study. On a scale of 1-6 (1=most favorable; 6=least favorable regarding overall appearance, shape, colors, thickness and length), NovoPen Echo received the most favorable rating for design and overall appearance (mean±standard deviation=1.71±0.79) compared with NovoPen Junior (2.02±0.93) and HumaPen Luxura HD (2.36±1.01). Furthermore, 89% of pediatric subjects and 94% of parents rated the memory function of NovoPen Echo as very easy/easy to use. When asked to rate the pens overall, 80% of participants preferred NovoPen Echo to the other pens (p<0.0001). CONCLUSIONS The results demonstrate a high overall level of satisfaction with NovoPen Echo among pediatric subjects, parents, and HCPs. The novel design aspects of NovoPen Echo, namely the simple memory function, half-increment units and, ease of use and design, may contribute towards promoting treatment adherence, which is essential in the pediatric setting.
Collapse
|
610
|
Abstract
Wheelchair prescription is complex with thousands of choices and options. Theoretically, a higher quality or innovative wheelchair that is appropriately matched to the user and their unique needs will increase participation. It is well accepted that there is an alarmingly high incidence of carpal tunnel syndrome, and rotator cuff injuries among manual wheelchair users. Since the initial conceptualization, the SMART(Wheel) was intended to better understand the physiological and physical effects of wheelchair propulsion on the body. Initially, little was known about wheelchair propulsion and the SMART(Wheel) transformed the nascent field of wheelchair propulsion biomechanics. Although still an important area of clinical research, the SMART(Wheel) has been critical to the study of the relationship between the type of wheelchair, set-up, activity, technique, anatomy, and physiology and repetitive strain injury. There has been growing evidence that the wheelchair-user interaction explains a substantial portion of the risk of developing a degenerative injury and on community participation. A noteworthy contribution of this work was the release of the clinical practice guideline, entitled, Preservation of Upper Limb Function Following Spinal Cord Injury in 2005. The SMART(Wheel) has been used by other scientists in areas that were not originally envisioned to be applications. It has been used to support the design of tools for developing a trail mapping rating and description system. It has also supported the design of accessible pedestrian walkways standards, accessible playground surfaces, and to evaluate carpets for wheelchair accessibility. It is likely that there are more new areas of exploration to emerge. This article describes the evolution of the SMART(Wheel) as new technologies became available and its applications in the field of wheelchair biomechanics and clinical service delivery.
Collapse
|
611
|
Bacchetti S, Pasqual E, Crozzolo E, Pellarin A, Cagol PP. Intra-arterial hepatic chemotherapy for unresectable colorectal liver metastases: a review of medical devices complications in 3172 patients. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2009; 2:31-40. [PMID: 22915912 PMCID: PMC3417858 DOI: 10.2147/mder.s4036] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Background Hepatic artery infusion (HAI) is indicated to treat unresectable colorectal hepatic metastases, with recent applications as a neoadjuvant or adjuvant treatment. Traditionally performed with the infusion of fluoropyrimidine-based chemotherapy, it has been now tested with oxaliplatin or irinotecan and associated with systemic chemotherapy. Methods To evaluate the impact of medical devices complications we carried out a search of the published studies on HAI in unresectable colorectal liver metastases. Complications were pooled according to the applied medical system: 1) surgical catheter, 2) radiological catheter, and 3) fully implantable pump. The surgical catheter is inserted into the hepatic artery from the gastro-duodenal artery. The radiological catheter is inserted into the hepatic artery through a percutaneous transfemoral or transaxillar access. The fully implantable pump is a totally internal medical device connected to the arterial hepatic catheter during laparotomy. Results The selection criteria were met in 47/319 studies. The complications of surgical and radiological medical devices connected to a port were found in 16 and 14 studies respectively. Meanwhile, complications with a fully implantable pump were reported in 17 studies. The total number of complications reported in studies evaluating patients with surgical or radiological catheter were 322 (322/948, 34%) and 261 (261/722, 36.1%) respectively. In studies evaluating patients with a fully implantable pump, the total number of complications was 237 (237/1502, 15.8%). In 18/319 studies the number of cycles was reported. The median number of cycles with surgically and radiologically implanted catheters was 8 and 6 respectively. The fully implantable pump allows a median number of 12 cycles. Conclusions The fully implantable pump, maintaining a continuous infusion through the system, allows the lowest risk for thrombosis and infection and the best median number of cycles of loco-regional chemotherapy in HAI.
Collapse
|
612
|
Shah AR, Goyal RK. Current status of the regulation for medical devices. Indian J Pharm Sci 2008; 70:695-700. [PMID: 21369427 PMCID: PMC3040860 DOI: 10.4103/0250-474x.49085] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2006] [Revised: 04/28/2008] [Accepted: 11/04/2008] [Indexed: 11/04/2022] Open
Abstract
In the light of escalating use of medical devices, stringent regulatory standards are required to ensure that the devices are safe, well studied and have least adverse reactions. Recently introduced guidelines and the amendment in the law will provide adequate guidance for both the manufacturers and competent authorities to manage cases efficiently and appropriately. India has emerged as one of the leaders in pharmaceutical industry. Like many other amendments in Drugs and Cosmetics Act that have boosted the global confidence in pharmaceutical industry in India, guidelines for devices will encourage the much needed research in medical devices. Pharmacy personnel can certainly play an important role in the regulation of medical devices. Safety, risks, effectiveness and performance of the medial devices need to be well established and regulated properly. It is hoped that the guidelines are implemented and regulated properly with effective outcome.
Collapse
|
613
|
Großkopf V, Jäkel C. Legal framework conditions for the reprocessing of medical devices. GMS KRANKENHAUSHYGIENE INTERDISZIPLINAR 2008; 3:Doc24. [PMID: 20204096 PMCID: PMC2831257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
Abstract
The processing of single-use products is permissible pursuant to medical device law. This is apparent both from the wording of the German Law on Medical Devices and from the purpose and the objectives underpinning the legislative materials. The prerequisite for processing is, however, compliance with the the Joint Recommendation of the Commission for Hospital Hygiene and the Prevention of Infection at the Robert Koch Institute (RKI) and the Federal Institute for Drugs and Medical Products (BfArM).For medical devices in the category "critical C", the RKI/BfArM-recommendation provides that the processor's quality management system must be certified by a body accredited by the Central Authority of the Federal States for Health Protection with regard to Medicinal Products and Medical Devices (Zentralstelle der Länder für Gesundheitsschutz bei Arzneimitteln und Medizinprodukten, ZLG). The certification must be carried out in accordance with EN ISO 13485:2003+AC:2007.On April 4, 2008 the Federal Health Ministry (Bundesministerium für Gesundheit, BMG) presented a progress report on the processing of medical devices. The BMG concludes that the legal framework for the processing of medical devices is sufficient, and that a prohibition on the processing of single-use products is inappropriate.
Collapse
|
614
|
Schneck MJ. Critical appraisal of medical devices in the management of cerebrovascular disease. Ther Clin Risk Manag 2008; 4:19-29. [PMID: 18728708 PMCID: PMC2503654 DOI: 10.2147/tcrm.s106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Medical devices may revolutionize the management of acute ischemic stroke and prevention of recurrent events. By comparison with pharmaceuticals, the device approval process and subsequent application of these devices in stroke treatment is founded on a paucity of Class I evidence-based clinical trial data. Thromboembolectomy for acute stroke, stenting of cervical or cerebral arteries for stroke prevention, and percutaneous closure of patent foramen ovale for prevention or recurrent cerebral ischemia are being done with an ever-increasing frequency despite few, if any, randomized clinical trials to confirm the appropriateness of the interventions. The current basis, or lack thereof, for these interventions for cerebrovascular disease is therefore discussed. As such, a critical appraisal of the available clinical data does not support widespread use of medical devices at this time outside of well-designed clinical trials.
Collapse
|
615
|
Chiao JC. Metrology and Standards Needs for Some Categories of Medical Devices. JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY 2008; 113:121-129. [PMID: 27096115 PMCID: PMC4654069 DOI: 10.6028/jres.113.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 03/05/2008] [Indexed: 06/05/2023]
Abstract
With rapid advances in meso-, micro- and nano-scale technology devices and electronics, a new generation of advanced medical devices is emerging, which promises medical treatment that is less invasive and more accurate, automated, and effective. We examined the technological and economic status of five categories of medical devices. A set of metrology needs is identified for each of these categories and suggestions are made to address them.
Collapse
|
616
|
Gurel O. Diabetes: medical vs surgical disease? J Diabetes Sci Technol 2008; 2:135-8. [PMID: 19885189 PMCID: PMC2769697 DOI: 10.1177/193229680800200120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The distinction between the medical and the surgical approach to disease has been a cornerstone of medical practice, and indeed with respect to the business and technology of medicine. It is common knowledge that diabetes is a medical disease-namely that drug therapy, whether it be via insulin or other medications, is the primary approach to therapy. This article argues that a reevaluation of the generalized (e.g., medication-based) approach to systemic blood sugar control may be in order. A consideration of the growing importance of interventional, device-based, or other surgical approaches to the primary management of diabetes has enormous implications for clinical practice as well as, of course, the business and technology of diabetes care.
Collapse
|
617
|
Yao C, Storey D, Webster TJ. Nanostructured metal coatings on polymers increase osteoblast attachment. Int J Nanomedicine 2007; 2:487-92. [PMID: 18019846 PMCID: PMC2676648] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Bioactive coatings are in high demand to increase the functions of cells for numerous medical devices. The objective of this in vitro study was to characterize osteoblast (bone-forming cell) adhesion on several potential orthopedic polymeric materials (specifically, polyetheretherketone, ultra-high molecular weight polyethylene, and polytetrafluoroethylene) coated with either titanium or gold using a novel Ionic Plasma Deposition process which creates a surface-engineered nanostructure (with features below 100 nm). Results demonstrated that compared to currently-used titanium and uncoated polymers, polymers coated with either titanium or gold using Ionic Plasma Deposition significantly increased osteoblast adhesion. Qualitative cell morphology results supported quantitative adhesion results as increased osteoblast cell spreading was observed on coated polymers compared to uncoated polymers. In this manner, this in vitro study strongly suggests that Ionic Plasma Deposition should be further studied for creating nanometer surface features on a wide variety of materials to enhance osteoblast functions necessary for orthopedic applications.
Collapse
|
618
|
Rogers WA, Essa IA, Fisk AD. Designing a Technology Coach: A multidisciplinary team models a system that can alert users of a complex medical device when they make an error. ERGONOMICS IN DESIGN 2007; 15:17-23. [PMID: 22545001 PMCID: PMC3337858 DOI: 10.1177/106480460701500303] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Technology in the home environment has the potential to support older adults in a variety of ways. We took an interdisciplinary approach (human factors/ergonomics and computer science) to develop a technology "coach" that could support older adults in learning to use a medical device. Our system provided a computer vision system to track the use of a blood glucose meter and provide users with feedback if they made an error. This research could support the development of an in-home personal assistant to coach individuals in a variety of tasks necessary for independent living.
Collapse
|
619
|
Milović NM, Behr JR, Godin M, Hou CSJ, Payer KR, Chandrasekaran A, Russo PR, Sasisekharan R, Manalis SR. Monitoring of heparin and its low-molecular-weight analogs by silicon field effect. Proc Natl Acad Sci U S A 2006; 103:13374-9. [PMID: 16938875 PMCID: PMC1569171 DOI: 10.1073/pnas.0604471103] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2006] [Indexed: 11/18/2022] Open
Abstract
Heparin is a highly sulfated glycosaminoglycan that is used as an important clinical anticoagulant. Monitoring and control of the heparin level in a patient's blood during and after surgery is essential, but current clinical methods are limited to indirect and off-line assays. We have developed a silicon field-effect sensor for direct detection of heparin by its intrinsic negative charge. The sensor consists of a simple microfabricated electrolyte-insulator-silicon structure encapsulated within microfluidic channels. As heparin-specific surface probes the clinical heparin antagonist protamine or the physiological partner antithrombin III were used. The dose-response curves in 10% PBS revealed a detection limit of 0.001 units/ml, which is orders of magnitude lower than clinically relevant concentrations. We also detected heparin-based drugs such as the low-molecular-weight heparin enoxaparin (Lovenox) and the synthetic pentasaccharide heparin analog fondaparinux (Arixtra), which cannot be monitored by the existing near-patient clinical methods. We demonstrated the specificity of the antithrombin III functionalized sensor for the physiologically active pentasaccharide sequence. As a validation, we showed correlation of our measurements to those from a colorimetric assay for heparin-mediated anti-Xa activity. These results demonstrate that silicon field-effect sensors could be used in the clinic for routine monitoring and maintenance of therapeutic levels of heparin and heparin-based drugs and in the laboratory for quantitation of total amount and specific epitopes of heparin and other glycosaminoglycans.
Collapse
|
620
|
Baek HS, Yoo JY, Rah DK, Han DW, Lee DH, Kwon OH, Park JC. Evaluation of the extraction method for the cytotoxicity testing of latex gloves. Yonsei Med J 2005; 46:579-83. [PMID: 16127787 PMCID: PMC2815847 DOI: 10.3349/ymj.2005.46.4.579] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
In this study, the cytotoxicity of medical latex gloves to cultured L-929 cells was determined using various extraction conditions. According to the extraction time and temperature, three types of extraction conditions were used: 1) 24 h at 37 degrees C; 2) 72 h at 37 degrees C; 3) 72 h at 50 degrees C. Also, four different extraction vehicles were used, namely, distilled water (DW), 9 g/l sodium chloride (saline) in DW, and culture media with or without serum. Under the above-mentioned conditions, the samples were extracted and then 2-fold serially diluted in the concentration range 3.13 - 50%. When extracted with either DW or saline for 24 h or 72 h at 37 degrees C, only 50% diluted samples showed distinct cytotoxicity to L-929 cells. Moreover, no cytotoxic potentials were observed when gloves were extracted with DW or saline at 50 degrees C for 72 h. Cytotoxicity was markedly greater when gloves were extracted with culture medium, irrespective of the presence of serum in the medium. These results suggest that optimal extraction conditions should be established for the cytotoxicity evaluations of biomaterials and medical devices.
Collapse
|
621
|
Johnson K, Pearce F, Westenskow D, Ogden LL, Farnsworth S, Peterson S, White J, Slade T. Clinical evaluation of the Life Support for Trauma and Transport (LSTAT) platform. Crit Care 2002; 6:439-46. [PMID: 12398785 PMCID: PMC130145 DOI: 10.1186/cc1538] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2001] [Revised: 05/13/2002] [Accepted: 05/31/2002] [Indexed: 11/10/2022] Open
Abstract
INTRODUCTION The Life Support for Trauma and Transport (LSTAT trade mark ) is a self-contained, stretcher-based miniature intensive care unit designed by the United States Army to provide care for critically injured patients during transport and in remote settings where resources are limited. The LSTAT contains conventional medical equipment that has been integrated into one platform and reduced in size to fit within the dimensional envelope of a North Atlantic Treaty Organization (NATO) stretcher. This study evaluated the clinical utility of the LSTAT in simulated and real clinical environments. Our hypothesis was that the LSTAT would be equivalent to conventional equipment in detecting and treating life-threatening problems. METHODS Thirty-one anesthesiologists and recovery room nurses compared the LSTAT with conventional monitors while managing four simulated critical events. The time required to reach a diagnosis and treatment was recorded for each simulation. Subsequently, 10 consenting adult patients were placed on the LSTAT after surgery for postoperative care in the recovery room. Questionnaires about aspects of LSTAT functionality were completed by nine nurses who cared for the patients placed on the LSTAT. RESULTS In all of the simulations, there was no clinically significant difference in the time to diagnosis or treatment between the LSTAT and conventional equipment. All clinicians reported that they were able to manage the simulated patients properly with the LSTAT. Nursing staff reported that the LSTAT provided adequate equipment to care for the patients monitored during recovery from surgery and were able to detect critical changes in vital signs in a timely manner. DISCUSSION Preliminary evaluation of the LSTAT in simulated and postoperative environments demonstrated that the LSTAT provided appropriate equipment to detect and manage critical events in patient care. Further work in assessing LSTAT functionality in a higher-acuity environment is warranted.
Collapse
|
622
|
Abstract
This article reviews the regulation of medical devices in the UK and Europe and compares the regulatory regime with that for pharmaceuticals. The regulation of devices follows the 'New Approach' policy of the EC Commission and involves more self-regulation and conformity assessment. The controls are relatively recent beginning in 1993 for Active Implantable Devices and concluding with the In Vitro Diagnostic Directive implemented in June 2000. The article describes how the directives have been implemented in the UK, the role of the Notified Bodies and the role of the Medical Device Agency (MDA) as the competent authority. In particular the Agency's compliance and standards work is described along with the strategy and post marketing surveillance and adverse incident scheme. The MDA is a key international device regulatory agency and its international role is discussed. So too is its device evaluation programme for the NHS and how this complements the work of NICE. The article also considers the future direction of the MDA and changes in the device sector.
Collapse
|