Ogata H, Negishi Y, Koizumi N, Nagayama H, Kaneko M, Kiyono K, Omi N. Individually optimized estimation of energy expenditure in rescue workers using a tri-axial accelerometer and heart rate monitor. Front Physiol 2024; 15:1322881. [PMID: 38434137 PMCID: PMC10905789 DOI: 10.3389/fphys.2024.1322881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 01/23/2024] [Indexed: 03/05/2024] Open
Abstract
Objectives: This study aimed to provide an improved energy expenditure estimation for heavy-load physical labor using accelerometer data and heart rate (HR) measured by wearables and to support food preparation and supply management for disaster relief and rescue operations as an expedition team. Methods: To achieve an individually optimized estimation for energy expenditure, a model equation parameter was determined based on the measurements of physical activity and HR during simulated rescue operations. The metabolic equivalent of task (MET), which was measured by using a tri-axial accelerometer and individual HR, was used, where two (minimum and maximum) or three (minimum, intermediate, and maximum) representative reference points were selected for each individual model fitting. In demonstrating the applicability of our approach in a realistic situation, accelerometer-based METs and HR of 30 males were measured using the tri-axial accelerometer and wearable HR during simulated rescue operations over 2 days. Results: Data sets of 27 rescue operations (age:34.2 ± 7.5 years; body mass index (BMI):22.9 ± 1.5 kg/m2) were used for the energy expenditure estimation after excluding three rescue workers due to their activity type and insufficient HR measurement. Using the combined approach with a tri-axial accelerometer and HR, the total energy expenditure increased by 143% for two points and 133% for three points, compared with the estimated total energy expenditure using only the accelerometer-based method. Conclusion: The use of wearables provided a reasonable estimation of energy expenditure for physical workers with heavy equipment. The application of our approach to disaster relief and rescue operations can provide important insights into nutrition and healthcare management.
Collapse
|
52
|
Kohler I, Perrotta MV, Ferreira T, Eagleman DM. Cross-Modal Sensory Boosting to Improve High-Frequency Hearing Loss: Device Development and Validation. JMIRX MED 2024; 5:e49969. [PMID: 38345294 PMCID: PMC11008433 DOI: 10.2196/49969] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 11/23/2023] [Accepted: 12/13/2023] [Indexed: 04/13/2024]
Abstract
Background High-frequency hearing loss is one of the most common problems in the aging population and with those who have a history of exposure to loud noises. This type of hearing loss can be frustrating and disabling, making it difficult to understand speech communication and interact effectively with the world. Objective This study aimed to examine the impact of spatially unique haptic vibrations representing high-frequency phonemes on the self-perceived ability to understand conversations in everyday situations. Methods To address high-frequency hearing loss, a multi-motor wristband was developed that uses machine learning to listen for specific high-frequency phonemes. The wristband vibrates in spatially unique locations to represent which phoneme was present in real time. A total of 16 participants with high-frequency hearing loss were recruited and asked to wear the wristband for 6 weeks. The degree of disability associated with hearing loss was measured weekly using the Abbreviated Profile of Hearing Aid Benefit (APHAB). Results By the end of the 6-week study, the average APHAB benefit score across all participants reached 12.39 points, from a baseline of 40.32 to a final score of 27.93 (SD 13.11; N=16; P=.002, 2-tailed dependent t test). Those without hearing aids showed a 10.78-point larger improvement in average APHAB benefit score at 6 weeks than those with hearing aids (t14=2.14; P=.10, 2-tailed independent t test). The average benefit score across all participants for ease of communication was 15.44 (SD 13.88; N=16; P<.001, 2-tailed dependent t test). The average benefit score across all participants for background noise was 10.88 (SD 17.54; N=16; P=.03, 2-tailed dependent t test). The average benefit score across all participants for reverberation was 10.84 (SD 16.95; N=16; P=.02, 2-tailed dependent t test). Conclusions These findings show that vibrotactile sensory substitution delivered by a wristband that produces spatially distinguishable vibrations in correspondence with high-frequency phonemes helps individuals with high-frequency hearing loss improve their perceived understanding of verbal communication. Vibrotactile feedback provides benefits whether or not a person wears hearing aids, albeit in slightly different ways. Finally, individuals with the greatest perceived difficulty understanding speech experienced the greatest amount of perceived benefit from vibrotactile feedback.
Collapse
|
53
|
Ahn CY, Lee JS. Digital Phenotyping for Real-Time Monitoring of Nonsuicidal Self-Injury: Protocol for a Prospective Observational Study. JMIR Res Protoc 2024; 13:e53597. [PMID: 38329791 PMCID: PMC10884894 DOI: 10.2196/53597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 12/29/2023] [Accepted: 01/18/2024] [Indexed: 02/09/2024] Open
Abstract
BACKGROUND Nonsuicidal self-injury (NSSI) is a major global health concern. The limitations of traditional clinical and laboratory-based methodologies are recognized, and there is a pressing need to use novel approaches for the early detection and prevention of NSSI. Unfortunately, there is still a lack of basic knowledge of a descriptive nature on NSSI, including when, how, and why self-injury occurs in everyday life. Digital phenotyping offers the potential to predict and prevent NSSI by assessing objective and ecological measurements at multiple points in time. OBJECTIVE This study aims to identify real-time predictors and explain an individual's dynamic course of NSSI. METHODS This study will use a hybrid approach, combining elements of prospective observational research with non-face-to-face study methods. This study aims to recruit a cohort of 150 adults aged 20 to 29 years who have self-reported engaging in NSSI on 5 or more days within the past year. Participants will be enrolled in a longitudinal study conducted at 3-month intervals, spanning 3 long-term follow-up phases. The ecological momentary assessment (EMA) technique will be used via a smartphone app. Participants will be prompted to complete a self-injury and suicidality questionnaire and a mood appraisal questionnaire 3 times a day for a duration of 14 days. A wrist-worn wearable device will be used to collect heart rate, step count, and sleep patterns from participants. Dynamic structural equation modeling and machine learning approaches will be used. RESULTS Participant recruitment and data collection started in October 2023. Data collection and analysis are expected to be completed by December 2024. The results will be published in a peer-reviewed journal and presented at scientific conferences. CONCLUSIONS The insights gained from this study will not only shed light on the underlying mechanisms of NSSI but also pave the way for the development of tailored and culturally sensitive treatment options that can effectively address this major mental health concern. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID) DERR1-10.2196/53597.
Collapse
|
54
|
Herrin KR, Kwak ST, Rock CG, Chang YH. Gait quality in prosthesis users is reflected by force-based metrics when learning to walk on a new research-grade powered prosthesis. FRONTIERS IN REHABILITATION SCIENCES 2024; 5:1339856. [PMID: 38370855 PMCID: PMC10869520 DOI: 10.3389/fresc.2024.1339856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 01/12/2024] [Indexed: 02/20/2024]
Abstract
Introduction Powered prosthetic feet require customized tuning to ensure comfort and long-term success for the user, but tuning in both clinical and research settings is subjective, time intensive, and the standard for tuning can vary depending on the patient's and the prosthetist's experience levels. Methods Therefore, we studied eight different metrics of gait quality associated with use of a research-grade powered prosthetic foot in seven individuals with transtibial amputation during treadmill walking. We compared clinically tuned and untuned conditions with the goal of identifying performance-based metrics capable of distinguishing between good (as determined by a clinician) from poor gait quality. Results Differences between the tuned and untuned conditions were reflected in ankle power, both the vertical and anterior-posterior impulse symmetry indices, limb-force alignment, and positive ankle work, with improvements seen in all metrics during use of the tuned prosthesis. Discussion Notably, all of these metrics relate to the timing of force generation during walking which is information not directly accessible to a prosthetist during a typical tuning process. This work indicates that relevant, real-time biomechanical data provided to the prosthetist through the future provision of wearable sensors may enhance and improve future clinical tuning procedures associated with powered prostheses as well as their long-term outcomes.
Collapse
|
55
|
Olejua P, McLain AC, Inak N, Dowda M, Pate RR. Clustering Patterns of 24-Hour Physical Activity in Children 6-36 Months Old. Pediatr Exerc Sci 2024:1-8. [PMID: 38307017 DOI: 10.1123/pes.2023-0055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 11/15/2023] [Accepted: 11/27/2023] [Indexed: 02/04/2024]
Abstract
PURPOSE To determine 24-hour physical activity (PA) clusters in children 6-36 months of age, factors associated with the clusters, and their agreement across time. METHOD A longitudinal study followed 150 infants from South Carolina up to 36 months of age. Measures included 24-hour PA and demographic data. Functional clustering was used to obtain the clusters. The association between cluster membership and infant/parent characteristics was examined by Kruskal-Wallis and chi-squared tests. Concordance was measured with the kappa coefficient and percent agreement. RESULTS At each follow-up, 3 clusters were optimal, identified as late activity (cluster 1), high activity (cluster 2), and medium activity (cluster 3). The defining feature of the late activity cluster was that their physical activity (PA) activity was shifted to later in the day versus children in clusters 2 and 3. At 6 months, the clusters were associated with race (<0.001), crawling (0.043), other children in the household (0.043), and mother's education (0.004); at 12 months with race (0.029), childcare (<0.001), and education (<0.001); and at 36 months with other children in the household (0.019). Clusters showed moderate agreement (kappa = .41 [.25 to .57], agreement = 61% [49% to 72%]) between 6 and 12 months and, at 36 months, showed no agreement with either 6 or 12 months. CONCLUSION Twenty-four-hour PA can be clustered into medium, high, and late PA. Further research is needed into the consequences of late sleeping in children at this age. Clusters are associated with household and childcare factors, and cluster membership is dynamic across time.
Collapse
|
56
|
Robinson SA, Shimada SL, Zocchi MS, Etingen B, Smith B, McMahon N, Cutrona SL, Harmon JS, Wilck NR, Hogan TP. Factors Associated with Veteran Self-Reported Use of Digital Health Devices. J Gen Intern Med 2024; 39:79-86. [PMID: 38252248 PMCID: PMC10937849 DOI: 10.1007/s11606-023-08479-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Accepted: 10/12/2023] [Indexed: 01/23/2024]
Abstract
BACKGROUND Digital health devices (DHDs), technologies designed to gather, monitor, and sometimes share data about health-related behaviors or symptoms, can support the prevention or management of chronic conditions. DHDs range in complexity and utility, from tracking lifestyle behaviors (e.g., pedometer) to more sophisticated biometric data collection for disease self-management (e.g., glucometers). Despite these positive health benefits, supporting adoption and sustained use of DHDs remains a challenge. OBJECTIVE This analysis examined the prevalence of, and factors associated with, DHD use within the Veterans Health Administration (VHA). DESIGN National survey. PARTICIPANTS Veterans who receive VHA care and are active secure messaging users. MAIN MEASURES Demographics, access to technology, perceptions of using health technologies, and use of lifestyle monitoring and self-management DHDs. RESULTS Among respondents, 87% were current or past users of at least one DHD, and 58% were provided a DHD by VHA. Respondents 65 + years were less likely to use a lifestyle monitoring device (AOR 0.57, 95% CI [0.39, 0.81], P = .002), but more likely to use a self-management device (AOR 1.69, 95% [1.10, 2.59], P = .016). Smartphone owners were more likely to use a lifestyle monitoring device (AOR 2.60, 95% CI [1.42, 4.75], P = .002) and a self-management device (AOR 1.83, 95% CI [1.04, 3.23], P = .037). CONCLUSIONS The current analysis describes the types of DHDs that are being adopted by Veterans and factors associated with their adoption. Results suggest that various factors influence adoption, including age, access to technology, and health status, and that these relationships may differ based on the functionalities of the device. VHA provision of devices was frequent among device users. Providing Veterans with DHDs and the training needed to use them may be important factors in facilitating device adoption. Taken together, this knowledge can inform future implementation efforts, and next steps to support patient-team decision making about DHD use.
Collapse
|
57
|
Sholokhova K, Jian WS, Yang HC, Li YCJ. Adjustable Cuffless Smartphone Attachment (ACSA+) for Estimation of Blood Pressure Trends: A Pilot Study. Stud Health Technol Inform 2024; 310:534-538. [PMID: 38269866 DOI: 10.3233/shti231022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2024]
Abstract
Among the elderly, hypertension remains one of the prevalent health conditions, which requires monitoring and intervention strategies. Nevertheless, regular reporting of blood pressure (BP) from these individuals still poses multiple challenges. However, most people own cell phone and are engaged in phone conversations daily. Here, we propose an adjustable cuffless smartphone attachment (ACSA+) equipped with a PPG sensor for the estimation of BP during phone conversations. ACSA+ can be easily attached to the back of any modern cell phone. ACSA+ will help to continuously collect BP data and store it as a trend line.
Collapse
|
58
|
Azadi B, Haslgrübler M, Anzengruber-Tanase B, Sopidis G, Ferscha A. Robust Feature Representation Using Multi-Task Learning for Human Activity Recognition. SENSORS (BASEL, SWITZERLAND) 2024; 24:681. [PMID: 38276371 PMCID: PMC10819053 DOI: 10.3390/s24020681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 01/11/2024] [Accepted: 01/19/2024] [Indexed: 01/27/2024]
Abstract
Learning underlying patterns from sensory data is crucial in the Human Activity Recognition (HAR) task to avoid poor generalization when coping with unseen data. A key solution to such an issue is representation learning, which becomes essential when input signals contain activities with similar patterns or when patterns generated by different subjects for the same activity vary. To address these issues, we seek a solution to increase generalization by learning the underlying factors of each sensor signal. We develop a novel multi-channel asymmetric auto-encoder to recreate input signals precisely and extract indicative unsupervised futures. Further, we investigate the role of various activation functions in signal reconstruction to ensure the model preserves the patterns of each activity in the output. Our main contribution is that we propose a multi-task learning model to enhance representation learning through shared layers between signal reconstruction and the HAR task to improve the robustness of the model in coping with users not included in the training phase. The proposed model learns shared features between different tasks that are indeed the underlying factors of each input signal. We validate our multi-task learning model using several publicly available HAR datasets, UCI-HAR, MHealth, PAMAP2, and USC-HAD, and an in-house alpine skiing dataset collected in the wild, where our model achieved 99%, 99%, 95%, 88%, and 92% accuracy. Our proposed method shows consistent performance and good generalization on all the datasets compared to the state of the art.
Collapse
|
59
|
García-Luna MA, Jimenez-Olmedo JM, Pueo B, Manchado C, Cortell-Tormo JM. Concurrent Validity of the Ergotex Device for Measuring Low Back Posture. Bioengineering (Basel) 2024; 11:98. [PMID: 38275578 PMCID: PMC10812927 DOI: 10.3390/bioengineering11010098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 01/17/2024] [Accepted: 01/18/2024] [Indexed: 01/27/2024] Open
Abstract
Highlighting the crucial role of monitoring and quantifying lumbopelvic rhythm for spinal curvature, the Ergotex IMU, a portable, lightweight, cost-effective, and energy-efficient technology, has been specifically designed for the pelvic and lumbar area. This study investigates the concurrent validity of the Ergotex device in measuring sagittal pelvic tilt angle. We utilized an observational, repeated measures design with healthy adult males (mean age: 39.3 ± 7.6 y, body mass: 82.2 ± 13.0 kg, body height: 179 ± 8 cm), comparing Ergotex with a 3D optical tracking system. Participants performed pelvic tilt movements in anterior, neutral, and posterior conditions. Statistical analysis included paired samples t-tests, Bland-Altman plots, and regression analysis. The findings show minimal systematic error (0.08° overall) and high agreement between the Ergotex and optical tracking, with most data points falling within limits of agreement of Bland-Altman plots (around ±2°). Significant differences were observed only in the anterior condition (0.35°, p < 0.05), with trivial effect sizes (ES = 0.08), indicating that these differences may not be clinically meaningful. The high Pearson's correlation coefficients across conditions underscore a robust linear relationship between devices (r > 0.9 for all conditions). Regression analysis showed a standard error of estimate (SEE) of 1.1° with small effect (standardized SEE < 0.26 for all conditions), meaning that the expected average deviation from the true value is around 1°. These findings validate the Ergotex as an effective, portable, and cost-efficient tool for assessing sagittal pelvic tilt, with practical implications in clinical and sports settings where traditional methods might be impractical or costly.
Collapse
|
60
|
Sanchez Gomez J, Pramono RXA, Imtiaz SA, Rodriguez-Villegas E, Valido Morales A. Validation of a Wearable Medical Device for Automatic Diagnosis of OSA against Standard PSG. J Clin Med 2024; 13:571. [PMID: 38276077 PMCID: PMC10816319 DOI: 10.3390/jcm13020571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 01/16/2024] [Accepted: 01/17/2024] [Indexed: 01/27/2024] Open
Abstract
STUDY OBJECTIVE The objective of this study was to assess the accuracy of automatic diagnosis of obstructive sleep apnea (OSA) with a new, small, acoustic-based, wearable technology (AcuPebble SA100), by comparing it with standard type 1 polysomnography (PSG) diagnosis. MATERIAL AND METHODS This observational, prospective study was carried out in a Spanish hospital sleep apnea center. Consecutive subjects who had been referred to the hospital following primary care suspicion of OSA were recruited and underwent in-laboratory attended PSG, together with the AcuPebble SA100 device simultaneously overnight from January to December 2022. RESULTS A total of 80 patients were recruited for the trial. The patients had a median Epworth scoring of 10, a mean of 10.4, and a range of 0-24. The mean AHI obtained with PSG plus sleep clinician marking was 23.2, median 14.3 and range 0-108. The study demonstrated a diagnostic accuracy (based on AHI) of 95.24%, sensitivity of 92.86%, specificity of 97.14%, positive predictive value of 96.30%, negative predictive value of 94.44%, positive likelihood ratio of 32.50 and negative likelihood ratio of 0.07. CONCLUSIONS The AcuPebble SA100 (EU) device has demonstrated an accurate automated diagnosis of OSA in patients undergoing in-clinic sleep testing when compared against the gold-standard reference of in-clinic PSG.
Collapse
|
61
|
Kuwajima Y, Yamaguchi Y, Yamada Y, Morita T, Wiranata A, Minaminosono A, Hosoya N, Kakehi Y, Maeda S. Pocketable and Smart Electrohydrodynamic Pump for Clothes. ACS APPLIED MATERIALS & INTERFACES 2024; 16:1883-1891. [PMID: 38096263 PMCID: PMC10788827 DOI: 10.1021/acsami.3c15274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 11/24/2023] [Accepted: 11/27/2023] [Indexed: 01/12/2024]
Abstract
Seamlessly fusing fashion and functionality can redefine wearable technology and enhance the quality of life. We propose a pocketable and smart electrohydrodynamic pump (PSEP) with self-sensing capability for wearable thermal controls. Overcoming the constraints of traditional liquid-cooled wearables, PSEP with dimensions of 10 × 2 × 1.05 cm and a weight of 10 g is sufficiently compact to fit into a shirt pocket, providing stylish and unobtrusive thermal control. Silent operation coupled with the unique self-sensing ability to monitor the flow rate ensures system reliability without cumbersome additional components. The significant contribution of our study is the formulation and validation of a theoretical model for self-sensing in EHD pumps, thereby introducing an innovative functionality to EHD pump technology. PSEP can deliver temperature changes of up to 3 °C, considerably improving personal comfort. Additionally, the PSEP system features an intuitive, smartphone-compatible interface for seamless wireless control and monitoring, enhancing user interaction and convenience. Furthermore, the ability to detect and notify users of flow blockages, achieved by self-sensing, ensures an efficient and long-term operation. Through its blend of compact design, intelligent functionality, and stylish integration into daily wear, PSEP reshapes the landscape of wearable thermal control technology and offers a promising avenue for enhancing personal comfort in daily life.
Collapse
|
62
|
Tucker S, Jonnalagadda S, Beseler C, Yoder A, Fruhling A. Exploring wearable technology use and importance of health monitoring in the hazardous occupations of first responders and professional drivers. J Occup Health 2024; 66:uiad002. [PMID: 38332724 PMCID: PMC11020306 DOI: 10.1093/joccuh/uiad002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 10/13/2023] [Accepted: 10/18/2023] [Indexed: 02/10/2024] Open
Abstract
OBJECTIVES Hazardous materials (HAZMAT) pose risks to the health and safety of professionals involved with transportation and emergency responses. Two distinct occupational groups that encounter HAZMAT events are first responders and professional drivers. Wearable technology is a tool that can assist with monitoring the health of professionals involved in HAZMAT events. The aim of this study was to compare and evaluate the perceptions of first responders and professional drivers on wearable technology and attitudes toward health monitoring. METHODS A survey was administered to first responders (n = 112) and professional drivers (n = 218). Statistical approaches included bivariate analysis, latent class analysis, logistic regression analysis, and path analysis for the variables of interest. RESULTS There were significant differences between the groups in perceptions of the benefits of monitoring certain health indicators. Professional drivers were more likely to have a history of wearable technology use compared with first responders (odds ratio [OR] = 10.1; 95% CI, 4.42-22.9), reported greater exposure to HAZMAT (OR = 4.32; 95% CI, 2.24-8.32), and were more willing to have their health data monitored by someone other than themselves (OR = 9.27; 95% CI, 3.67-23.4). A multinomial regression model revealed that occupation was not a significant predictor of class preference for acceptance of monitoring specific health indicators. CONCLUSIONS Occupation appeared to be important but further analysis uncovered that characteristics of individuals within the occupations were more salient to the use of wearable technology. HAZMAT exposure, someone else monitoring health data, and experience with wearable technology use were found to be important factors for perceptions about benefits of health monitoring with wearable technology.
Collapse
|
63
|
García-Luna MA, Ruiz-Fernández D, Tortosa-Martínez J, Manchado C, García-Jaén M, Cortell-Tormo JM. Transparency as a Means to Analyse the Impact of Inertial Sensors on Users during the Occupational Ergonomic Assessment: A Systematic Review. SENSORS (BASEL, SWITZERLAND) 2024; 24:298. [PMID: 38203160 PMCID: PMC10781389 DOI: 10.3390/s24010298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 12/19/2023] [Accepted: 01/03/2024] [Indexed: 01/12/2024]
Abstract
The literature has yielded promising data over the past decade regarding the use of inertial sensors for the analysis of occupational ergonomics. However, despite their significant advantages (e.g., portability, lightness, low cost, etc.), their widespread implementation in the actual workplace has not yet been realized, possibly due to their discomfort or potential alteration of the worker's behaviour. This systematic review has two main objectives: (i) to synthesize and evaluate studies that have employed inertial sensors in ergonomic analysis based on the RULA method; and (ii) to propose an evaluation system for the transparency of this technology to the user as a potential factor that could influence the behaviour and/or movements of the worker. A search was conducted on the Web of Science and Scopus databases. The studies were summarized and categorized based on the type of industry, objective, type and number of sensors used, body parts analysed, combination (or not) with other technologies, real or controlled environment, and transparency. A total of 17 studies were included in this review. The Xsens MVN system was the most widely used in this review, and the majority of studies were classified with a moderate level of transparency. It is noteworthy, however, that there is a limited and worrisome number of studies conducted in uncontrolled real environments.
Collapse
|
64
|
Van Hooren B, Willems P, Plasqui G, Meijer K. Changes in running economy and running technique following 6 months of running with and without wearable-based real-time feedback. Scand J Med Sci Sports 2024; 34:e14565. [PMID: 38268070 DOI: 10.1111/sms.14565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 11/23/2023] [Accepted: 01/07/2024] [Indexed: 01/26/2024]
Abstract
BACKGROUND An increasing number of commercially available wearables provide real-time feedback on running biomechanics with the aim to reduce injury risk or improve performance. OBJECTIVE Investigate whether real-time feedback by wearable insoles (ARION) alters running biomechanics and improves running economy more as compared to unsupervised running training. We also explored the correlation between changes in running biomechanics and running economy. METHODS Forty recreational runners were randomized to an intervention and control group and performed ~6 months of in-field training with or without wearable-based real-time feedback on running technique and speed. Running economy and running biomechanics were measured in lab conditions without feedback pre and post intervention at four speeds. RESULTS Twenty-two individuals (13 control, 9 intervention) completed both tests. Both groups significantly reduced their energetic cost by an average of -6.1% and -7.7% for the control and intervention groups, respectively. The reduction in energy cost did not significantly differ between groups overall (-0.07 ± 0.14 J∙kg∙m-1 , -1.5%, p = 0.63). There were significant changes in spatiotemporal metrics, but their magnitude was minor and did not differ between the groups. There were no significant changes in running kinematics within or between groups. However, alterations in running biomechanics beyond typical session-to-session variation were observed during some in-field sessions for individuals that received real-time feedback. CONCLUSION Alterations in running biomechanics as observed during some in-field sessions for individuals receiving wearable-based real-time feedback did not result in significant differences in running economy or running biomechanics when measured in controlled lab conditions without feedback.
Collapse
|
65
|
Thyla B, Bai VT. A very low-profile CPW based conformal antenna for wearable/implantable applications. Technol Health Care 2024; 32:103-115. [PMID: 37545263 DOI: 10.3233/thc-220534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/08/2023]
Abstract
BACKGROUND In wireless communication standard 4G and 5G, the body centric network plays an important role for the wireless communication between various devices. OBJECTIVE This research relates to a wide-band conformal co-planar waveguide (CPW) antenna for wearable applications. METHODS The proposed CPW antenna is printed on 0.1 mm thick bio-compatible polymide substrate whose dielectric constant and permittivity are 3.5 and 0.02 respectively. The total area of the antenna is around 17.5 × 15 mm2 which is significantly smaller than the wearable antennas proposed in literature. The proposed antenna is designed to operate in new ISM band 5.8 GHz with the bandwidth of 5.3-6.3 GHz with 2:1 Voltage Standing Wave Ratio (VSWR). The antenna is printed on the flexible substrate and hence robustness of device is evaluated by bending analysis. It reveals the superior performance of the designed CPW antenna over the desired spectrum of operation. RESULTS Specific Absorption Rate (SAR) is calculated after placing the antenna at various places of human phantom model and showed that SAR values are below 1.6 W/Kg which is the maximum margin recommended by Federal Communication Commission (FCC), i.e when tested with 1 g and 10 g of human tissue of phantom model, for the test frequency range of 5.5-6.1 GHz, SAR value falls between 0.9987 and 0.921 W/Kg respectively. The antenna also shows the radiation efficiency around 92% with overall realized gain 5.2 dBi which are substantial values for wearable applications. CONCLUSION The outcomes of this research revealed the feasibility of the recommended antenna becoming a major contender of future Internet of Things (IoT) applications.
Collapse
|
66
|
Vandenbussche N, Van Der Donckt J, De Brouwer M, Steenwinckel B, Stojchevska M, Ongenae F, Van Hoecke S, Paemeleire K. Patients with chronic cluster headache may show reduced activity energy expenditure on ambulatory wrist actigraphy recordings during daytime attacks. Brain Behav 2024; 14:e3360. [PMID: 38376015 PMCID: PMC10761329 DOI: 10.1002/brb3.3360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 11/23/2023] [Accepted: 11/25/2023] [Indexed: 02/21/2024] Open
Abstract
OBJECTIVE To investigate the changes in activity energy expenditure (AEE) throughout daytime cluster headache (CH) attacks in patients with chronic CH and to evaluate the usefulness of actigraphy as a digital biomarker of CH attacks. BACKGROUND CH is a primary headache disorder characterized by attacks of severe to very severe unilateral pain (orbital, supraorbital, temporal, or in any combination of these sites), with ipsilateral cranial autonomic symptoms and/or a sense of restlessness or agitation. We hypothesized increased AEE from hyperactivity during attacks measured by actigraphy. METHODS An observational study including patients with chronic CH was conducted. During 21 days, patients wore an actigraphy device on the nondominant wrist and recorded CH attack-related data in a dedicated smartphone application. Accelerometer data were used for the calculation of AEE before and during daytime CH attacks that occurred in ambulatory settings, and without restrictions on acute and preventive headache treatment. We compared the activity and movements during the pre-ictal, ictal, and postictal phases with data from wrist-worn actigraphy with time-concordant intervals during non-headache periods. RESULTS Four patients provided 34 attacks, of which 15 attacks met the eligibility criteria for further analysis. In contrast with the initial hypothesis of increased energy expenditure during CH attacks, a decrease in movement was observed during the pre-ictal phase (30 min before onset to onset) and during the headache phase. A significant decrease (p < .01) in the proportion of high-intensity movement during headache attacks, of which the majority were oxygen-treated, was observed. This trend was less present for low-intensity movements. CONCLUSION The unexpected decrease in AEE during the pre-ictal and headache phase of daytime CH attacks in patients with chronic CH under acute and preventive treatment in ambulatory settings has important implications for future research on wrist actigraphy in CH.
Collapse
|
67
|
Tas B, Walker H, Lawn W, Matcham F, Traykova EV, Evans RAS, Strang J. What impacts the acceptability of wearable devices that detect opioid overdose in people who use opioids? A qualitative study. Drug Alcohol Rev 2024; 43:213-225. [PMID: 37596977 DOI: 10.1111/dar.13737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 07/26/2023] [Accepted: 07/29/2023] [Indexed: 08/21/2023]
Abstract
INTRODUCTION Drug-related deaths involving an opioid are at all-time highs across the United Kingdom. Current overdose antidotes (naloxone) require events to be witnessed and recognised for reversal. Wearable technologies have potential for remote overdose detection or response but their acceptability among people who use opioids (PWUO) is not well understood. This study explored facilitators and barriers to wearable technology acceptability to PWUO. METHODS Twenty-four participants (79% male, average age 46 years) with current (n = 15) and past (n = 9) illicit heroin use and 54% (n = 13) who were engaged in opioid substitution therapy participated in semi-structured interviews (n = 7) and three focus groups (n = 17) in London and Nottingham from March to June 2022. Participants evaluated real devices, discussing characteristics, engagement factors, target populations, implementation strategies and preferences. Conversations were recorded, transcribed and thematically analysed. RESULTS Three themes emerged: device-, person- and environment-specific factors impacting acceptability. Facilitators included inconspicuousness under the device theme and targeting subpopulations of PWUO at the individual theme. Barriers included affordability of devices and limited technology access within the environment theme. Trust in device accuracy for high and overdose differentiation was a crucial facilitator, while trust between technology and PWUO was a significant environmental barrier. DISCUSSION AND CONCLUSIONS Determinants of acceptability can be categorised into device, person and environmental factors. PWUO, on the whole, require devices that are inconspicuous, comfortable, accessible, easy to use, controlled by trustworthy organisations and highly accurate. Device developers must consider how the type of end-user and their environment moderate acceptability of the device.
Collapse
|
68
|
Golparvar A, Thenot L, Boukhayma A, Carrara S. Soft Epidermal Paperfluidics for Sweat Analysis by Ratiometric Raman Spectroscopy. BIOSENSORS 2023; 14:12. [PMID: 38248389 PMCID: PMC10812966 DOI: 10.3390/bios14010012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 12/11/2023] [Accepted: 12/19/2023] [Indexed: 01/23/2024]
Abstract
The expanding interest in digital biomarker analysis focused on non-invasive human bodily fluids, such as sweat, highlights the pressing need for easily manufactured and highly efficient soft lab-on-skin solutions. Here, we report, for the first time, the integration of microfluidic paper-based devices (μPAD) and non-enhanced Raman-scattering-enabled optical biochemical sensing (Raman biosensing). Their integration merges the enormous benefits of μPAD, with high potential for commercialization and use in resource-limited settings, with biorecognition-element-free (but highly selective) optical Raman biosensing. The introduced thin (0.36 mm), ultra-lightweight (0.19 g), and compact footprint (3 cm2) opto-paperfluidic sweat patch is flexible, stretchable, and conforms, irritation-free, to hairless or minimally haired body regions to enable swift sweat collection. As a great advantage, this new bio-chemical sensory system excels through its absence of onboard biorecognition elements (bioreceptor-free) and omission of plasmonic nanomaterials. The proposed easy fabrication process is adaptable to mass production by following a fully sustainable and cost-effective process utilizing only basic tools by avoiding typically employed printing or laser patterning. Furthermore, efficient collection and transportation of precise sweat volumes, driven exclusively by the wicking properties of porous materials, shows high efficiency in liquid transportation and reduces biosensing latency by a factor of 5 compared to state-of-the-art epidermal microfluidics. The proposed unit enables electronic chip-free and imaging-less visual sweat loss quantification as well as optical biochemical analysis when coupled with Raman spectroscopy. We investigated the multimodal quantification of sweat urea and lactate levels ex vivo (with syntactic sweat including +30 sweat analytes on porcine skin) and achieved a linear dynamic range from 0 to 100 mmol/L during fully dynamic continuous flow characterization.
Collapse
|
69
|
Choi S, Sajib MRUZ, Manzano J, Chlebek CJ. mHealth Technology Experiences of Middle-Aged and Older Individuals With Visual Impairments: Cross-Sectional Interview Study. JMIR Form Res 2023; 7:e52410. [PMID: 38145472 PMCID: PMC10775026 DOI: 10.2196/52410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Revised: 11/25/2023] [Accepted: 11/30/2023] [Indexed: 12/26/2023] Open
Abstract
BACKGROUND Current mobile health (mHealth) technology is predominantly designed with a visual orientation, often resulting in user interfaces that are inaccessible to visually impaired users. While mHealth technology offers potential for facilitating chronic illness management and enhancing health behaviors among visually impaired older populations, understanding its usage remains limited. OBJECTIVE This qualitative research aimed to explore the mHealth technology experiences of middle-aged and older individuals with visual impairments including the accessibility and usability issues they faced. METHODS The qualitative exploration was structured using the mHealth for Older Users framework. Cross-sectional interviews were conducted via Zoom between June 1 and July 31, 2023, using an interview protocol for data collection. A thematic analysis approach was employed to analyze the transcribed interview scripts. RESULTS Of the 7 participants who took part in the Zoom interviews, 3 were men and 4 were women, with ages ranging from 53 to 70 years. Most participants adopted mHealth apps and wearable devices for promoting health. They exhibited 3 distinct adoption patterns. Seven themes were emerged from the perceived challenges in using mHealth technologies: (1) a scarcity of accessible user manuals, (2) user interfaces that are not visually impaired-friendly, (3) health data visualizations that are not accessible, (4) unintuitive arrangement of app content, (5) health information that is challenging to comprehend, (6) cognitive overload caused by an excess of audible information, and (7) skepticism regarding the accuracy of health records. mHealth technologies seem to positively affect the health and health management of participants. CONCLUSIONS Design considerations for mHealth technologies should consider individuals' disabilities and chronic conditions and should emphasize the importance of providing accessible manuals and training opportunities when introducing new mHealth solutions.
Collapse
|
70
|
Slopecki M, Charbonneau M, Lavallière JM, Côté JN, Clément J. Validation of Automatically Quantified Swim Stroke Mechanics Using an Inertial Measurement Unit in Paralympic Athletes. Bioengineering (Basel) 2023; 11:15. [PMID: 38247892 PMCID: PMC10813451 DOI: 10.3390/bioengineering11010015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 12/14/2023] [Accepted: 12/20/2023] [Indexed: 01/23/2024] Open
Abstract
Biomechanics and training load monitoring are important for performance evaluation and injury prevention in elite swimming. Monitoring of performance and swim stroke parameters is possible with inertial measurement units (IMU) but has not been validated in para-swimmers. The purpose of this study was to validate a single IMU-based system to accurately estimate pool-swam lap time, stroke count (SC), stroke duration, instantaneous stroke rate (ISR), and distance per stroke (DPS). Eight Paralympic athletes completed 4 × 50 m swims with an IMU worn on the sacrum. Strokes cycles were identified using a zero-crossing algorithm on the medio-lateral (freestyle and backstroke) or forward-backward (butterfly and breaststroke) instantaneous velocity data. Video-derived metrics were estimated using Dartfish and Kinovea. Agreement analyses, including Bland-Altman and Intraclass Correlation Coefficient (ICC), were performed on all outcome variables. SC Bland-Altman bias was 0.13 strokes, and ICC was 0.97. ISR Bland-Altman biases were within 1.5 strokes/min, and ICCs ranged from 0.26 to 0.96. DPS Bland-Altman biases were within 0.20 m, and ICCs ranged from 0.39 to 0.93. A single-IMU system can provide highly valid performance and swim stroke monitoring data for elite para-swimmers for the majority of strokes, with the exception of backstroke. Future work should improve bilateral stroke detection algorithms in this population.
Collapse
|
71
|
Han Y, Fang X, Li H, Zha L, Guo J, Zhang X. Sweat Sensor Based on Wearable Janus Textiles for Sweat Collection and Microstructured Optical Fiber for Surface-Enhanced Raman Scattering Analysis. ACS Sens 2023; 8:4774-4781. [PMID: 38051949 DOI: 10.1021/acssensors.3c01863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2023]
Abstract
Wearable sweat sensors provide real-time monitoring of biomarkers, enabling individuals to gain real-time insight into their health status. Current sensors primarily rely on electrochemical mechanisms, limiting their capacity for the concurrent detection of multiple analytes. Surface-enhanced Raman scattering spectroscopy offers an alternative approach by providing molecular fingerprint information to facilitate the identification of intricate analytes. In this study, we combine a wearable Janus fabric for efficient sweat collection and a grapefruit optical fiber embedded with Ag nanoparticles as a sensitive SERS probe. The Janus fabric features a superhydrophobic side in contact with the skin and patterned superhydrophilic regions on the opposite surface, facilitating the unidirectional flow of sweat toward these hydrophilic zones. Grapefruit optical fibers feature sharp tips with the ability to penetrate transparent dressings. Its microchannels extract sweat through capillary force, and nanoliter-scale volumes of sweat are sufficient to completely fill them. The Raman signal of sweat components is greatly enhanced by the plasmonic hot spots and accumulates along the fiber length. We demonstrate sensitive detection of sodium lactate and urea in sweat with a detection limit much lower than the physiological concentration levels. Moreover, the platform shows its capability for multicomponent detection and extends to the analysis of real human sweat.
Collapse
|
72
|
Nourse R, Dingler T, Kelly J, Kwasnicka D, Maddison R. The Role of a Smart Health Ecosystem in Transforming the Management of Chronic Health Conditions. J Med Internet Res 2023; 25:e44265. [PMID: 38109188 PMCID: PMC10758944 DOI: 10.2196/44265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 06/07/2023] [Accepted: 06/29/2023] [Indexed: 12/19/2023] Open
Abstract
The effective management of chronic conditions requires an approach that promotes a shift in care from the clinic to the home, improves the efficiency of health care systems, and benefits all users irrespective of their needs and preferences. Digital health can provide a solution to this challenge, and in this paper, we provide our vision for a smart health ecosystem. A smart health ecosystem leverages the interoperability of digital health technologies and advancements in big data and artificial intelligence for data collection and analysis and the provision of support. We envisage that this approach will allow a comprehensive picture of health, personalization, and tailoring of behavioral and clinical support; drive theoretical advancements; and empower people to manage their own health with support from health care professionals. We illustrate the concept with 2 use cases and discuss topics for further consideration and research, concluding with a message to encourage people with chronic conditions, their caregivers, health care professionals, policy and decision makers, and technology experts to join their efforts and work toward adopting a smart health ecosystem.
Collapse
|
73
|
Nissen M, Perez CA, Jaeger KM, Bleher H, Flaucher M, Huebner H, Danzberger N, Titzmann A, Pontones CA, Fasching PA, Beckmann MW, Eskofier BM, Leutheuser H. Usability and Perception of a Wearable-Integrated Digital Maternity Record App in Germany: User Study. JMIR Pediatr Parent 2023; 6:e50765. [PMID: 38109377 PMCID: PMC10750977 DOI: 10.2196/50765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 09/20/2023] [Accepted: 10/02/2023] [Indexed: 12/20/2023] Open
Abstract
Background Although digital maternity records (DMRs) have been evaluated in the past, no previous work investigated usability or acceptance through an observational usability study. Objective The primary objective was to assess the usability and perception of a DMR smartphone app for pregnant women. The secondary objective was to assess personal preferences and habits related to online information searching, wearable data presentation and interpretation, at-home examination, and sharing data for research purposes during pregnancy. Methods A DMR smartphone app was developed. Key features such as wearable device integration, study functionalities (eg, questionnaires), and common pregnancy app functionalities (eg, mood tracker) were included. Women who had previously given birth were invited to participate. Participants completed 10 tasks while asked to think aloud. Sessions were conducted via Zoom. Video, audio, and the shared screen were recorded for analysis. Task completion times, task success, errors, and self-reported (free text) feedback were evaluated. Usability was measured through the System Usability Scale (SUS) and User Experience Questionnaire (UEQ). Semistructured interviews were conducted to explore the secondary objective. Results A total of 11 participants (mean age 34.6, SD 2.2 years) were included in the study. A mean SUS score of 79.09 (SD 18.38) was achieved. The app was rated "above average" in 4 of 6 UEQ categories. Sixteen unique features were requested. We found that 5 of 11 participants would only use wearables during pregnancy if requested to by their physician, while 10 of 11 stated they would share their data for research purposes. Conclusions Pregnant women rely on their medical caregivers for advice, including on the use of mobile and ubiquitous health technology. Clear benefits must be communicated if issuing wearable devices to pregnant women. Participants that experienced pregnancy complications in the past were overall more open toward the use of wearable devices in pregnancy. Pregnant women have different opinions regarding access to, interpretation of, and reactions to alerts based on wearable data. Future work should investigate personalized concepts covering these aspects.
Collapse
|
74
|
Kawai K, Iwamoto K, Miyata S, Okada I, Fujishiro H, Noda A, Nakagome K, Ozaki N, Ikeda M. Comparison of Polysomnography, Single-Channel Electroencephalogram, Fitbit, and Sleep Logs in Patients With Psychiatric Disorders: Cross-Sectional Study. J Med Internet Res 2023; 25:e51336. [PMID: 38090797 PMCID: PMC10753421 DOI: 10.2196/51336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 11/02/2023] [Accepted: 11/20/2023] [Indexed: 12/18/2023] Open
Abstract
BACKGROUND Sleep disturbances are core symptoms of psychiatric disorders. Although various sleep measures have been developed to assess sleep patterns and quality of sleep, the concordance of these measures in patients with psychiatric disorders remains relatively elusive. OBJECTIVE This study aims to examine the degree of agreement among 3 sleep recording methods and the consistency between subjective and objective sleep measures, with a specific focus on recently developed devices in a population of individuals with psychiatric disorders. METHODS We analyzed 62 participants for this cross-sectional study, all having data for polysomnography (PSG), Zmachine, Fitbit, and sleep logs. Participants completed questionnaires on their symptoms and estimated sleep duration the morning after the overnight sleep assessment. The interclass correlation coefficients (ICCs) were calculated to evaluate the consistency between sleep parameters obtained from each instrument. Additionally, Bland-Altman plots were used to visually show differences and limits of agreement for sleep parameters measured by PSG, Zmachine, Fitbit, and sleep logs. RESULTS The findings indicated a moderate agreement between PSG and Zmachine data for total sleep time (ICC=0.46; P<.001), wake after sleep onset (ICC=0.39; P=.002), and sleep efficiency (ICC=0.40; P=.006). In contrast, Fitbit demonstrated notable disagreement with PSG (total sleep time: ICC=0.08; wake after sleep onset: ICC=0.18; sleep efficiency: ICC=0.10) and exhibited particularly large discrepancies from the sleep logs (total sleep time: ICC=-0.01; wake after sleep onset: ICC=0.05; sleep efficiency: ICC=-0.02). Furthermore, subjective and objective concordance among PSG, Zmachine, and sleep logs appeared to be influenced by the severity of the depressive symptoms and obstructive sleep apnea, while these associations were not observed between the Fitbit and other sleep instruments. CONCLUSIONS Our study results suggest that Fitbit accuracy is reduced in the presence of comorbid clinical symptoms. Although user-friendly, Fitbit has limitations that should be considered when assessing sleep in patients with psychiatric disorders.
Collapse
|
75
|
Yoshida K, Sawano R, Okamoto M, Murao K, Tsuchida S, Terada T. Physical Noninvasive Attacks on Photoplethysmogram by Computer Controlled Blood Pressure Cuff. SENSORS (BASEL, SWITZERLAND) 2023; 23:9764. [PMID: 38139610 PMCID: PMC10747835 DOI: 10.3390/s23249764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 11/29/2023] [Accepted: 12/07/2023] [Indexed: 12/24/2023]
Abstract
Sensor data has been used in social security and welfare infrastructures such as insurance and medical care to provide personalized products and services; there is a risk that attackers can alter sensor data to obtain unfair benefits. We consider that one of the attack methods to modify sensor data is to attack the wearer's body to modify biometric information. In this study, we propose a noninvasive attack method to modify the sensor value of a photoplethysmogram. The proposed method can disappear pulse wave peaks by pressurizing the upper arm with air pressure to control blood volume. Seven subjects experiencing a rest environment and five subjects experiencing an after-exercise environment wore five different models of smartwatches, and three pressure patterns were performed. It was confirmed in both situations that the displayed heart rate decreased from the true heart rate.
Collapse
|