51
|
Ji Kwon N, Han E. A review of drug abuse in recently reported cases of driving under the influence of drugs (DUID) in Asia, USA, and Europe. Forensic Sci Int 2019; 302:109854. [PMID: 31255839 DOI: 10.1016/j.forsciint.2019.06.012] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Revised: 06/05/2019] [Accepted: 06/09/2019] [Indexed: 11/17/2022]
Abstract
Driving Under the Influence of Drugs (DUID) is considered a serious issue related to the abuse of illegal drugs. DUID cases, including deaths, are being continuously reported in Asia, USA, and Europe. This literature review focuses on illegal drug abuse in recent DUID cases reported in Asia, USA, and Europe. To determine illegal drug abuse in DUID suspects, previous studies collected and analyzed biological samples, such as blood, urine, oral fluids, and hair. In addition, there were forensic autopsies and surveys for investigation of illegal drugs in DUID cases and drivers. In previous studies, ketamine, morphine, methamphetamine (MA), and khat were mainly reported in Asia, whereas amphetamine, benzodiazepines (BZDs), and cannabinoids were mainly reported in USA, and synthetic cannabinoids (SCs), opiates, and cocaine were mainly reported in Europe. Since DUID suspects related to illegal drugs have been frequently reported in Asia, USA, and Europe, there is a need to plan for national monitoring for drivers or motor vehicles to regulate and prevent drug abuse and relevant DUID cases.
Collapse
|
52
|
Campos-Mañas MC, Ferrer I, Thurman EM, Sánchez Pérez JA, Agüera A. Identification of opioids in surface and wastewaters by LC/QTOF-MS using retrospective data analysis. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 664:874-884. [PMID: 30769311 DOI: 10.1016/j.scitotenv.2019.01.389] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2018] [Revised: 01/29/2019] [Accepted: 01/29/2019] [Indexed: 06/09/2023]
Abstract
Opioids, both as prescription drugs and abuse substances, have been a hot topic and a focus of discussion in the media for the last few years. Although the literature published shows the occurrence of opioids and some of their metabolites in the aquatic environment, there are scarce data in the application of high resolution mass spectrometry (HRMS) for the analysis of these compounds in the environment. The use of HRMS allows increasing the number of opioids that can be studied as well as the detection of unknown opioids, their metabolites and potential transformation products. In this work, a retrospective analysis for the identification of opioids and their metabolites using a curated database was applied to surface water and wastewater samples taken in the state of Minnesota (U.S.) in 2009, which were previously analyzed by liquid chromatography/time-of-flight mass spectrometry (LC/TOF-MS) for antidepressants. The database comprised >200 opioids including natural opiates (e.g. morphine and codeine), their semi-synthetic derivatives (e.g. heroin, hydromorphone, hydrocodone, oxycodone, oxymorphone, meperidine and buprenorphine), fully synthetic opioids (e.g. fentanyl, methadone, tramadol, dextromethorphan and propoxyphene), as well as some of their metabolites (e.g. 6-monoacetylcodeine, dextrorphan, EDDP, normorphine and O-desmethyltramadol). Moreover, additional MS-MS experiments were performed to confirm their identification, as well as to recognize fragmentation patterns and diagnostic ions for several opioids. These data provide a better understanding of the historical occurrence of opioids and their metabolites in surface waters impacted by wastewater sources. The concentrations of individual opioids in surface water and wastewater effluent varied from 8.8 (EDDP) to 1640 (tramadol) ngL-1 and from 12 (dihydrocodeine) to 1288 (tramadol) ngL-1, respectively. The opioids with higher overall frequency detections were tramadol, dextromethorphan and its metabolite, dextrorphan.
Collapse
|
53
|
Salomone A, Palamar JJ, Bigiarini R, Gerace E, Di Corcia D, Vincenti M. Detection of Fentanyl Analogs and Synthetic Opioids in Real Hair Samples. J Anal Toxicol 2019; 43:259-265. [PMID: 30462247 PMCID: PMC6460334 DOI: 10.1093/jat/bky093] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2018] [Revised: 09/17/2018] [Accepted: 10/23/2018] [Indexed: 11/13/2022] Open
Abstract
Novel synthetic opioids include various analogs of fentanyl and emerging non-fentanyl compounds with different chemical structures, such as AH-7921, MT-45 and U-47700. In recent years, these drugs have rapidly emerged on the drug market, and their abuse has been increasing worldwide. The motivations for use of these new compounds include their legal status, ready availability, low cost, users' curiosity or preference for their particular pharmacological properties and the intention to avoid detection. Furthermore, more common drugs like heroin are now increasingly being replaced or cut with fentanyl or new designer opioids; thus, many drug users are unintentionally or unknowingly using synthetic fentanyl analogs. In this scenario, the detection of new psychoactive substances in hair can provide insight into their current diffusion among the population and social characteristics of these synthetic drug users. In this manuscript, we describe a simple, fast, specific and sensitive UHPLC-MS-MS method able to detect 13 synthetic opioids (including fentanyl analogs) and metabolites in hair samples. Furthermore, the method includes the detection of 4-anilino-N-phenethyl-piperidine (4-ANPP), which is considered both a precursor and a metabolite of several fentanyl analogs. The method was applied to 34 real hair samples collected in New York City from subjects who had reported past-year non-medical opioid and/or heroin use. In total, 17 samples tested positive for at least one target analyte, with oxycodone (nine samples) and tramadol (eight samples) being the most common. Among these, the method was able to quantify furanyl-fentanyl and fentanyl in the pg/mg range in two samples. Simultaneously, also 4-ANPP was detected, giving evidence for the first time that this compound can be selected as a marker of fentanyl analogs use via hair testing. In conclusion, this study confirmed the increasing diffusion of new synthetic opioids and "fentalogs" with high potency among non-medical opioid users.
Collapse
|
54
|
Krieger MS, Goedel WC, Buxton JA, Lysyshyn M, Bernstein E, Sherman SG, Rich JD, Hadland SE, Green TC, Marshall BDL. Use of rapid fentanyl test strips among young adults who use drugs. THE INTERNATIONAL JOURNAL OF DRUG POLICY 2018; 61:52-58. [PMID: 30344005 PMCID: PMC6701177 DOI: 10.1016/j.drugpo.2018.09.009] [Citation(s) in RCA: 96] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2018] [Revised: 08/31/2018] [Accepted: 09/04/2018] [Indexed: 01/10/2023]
Abstract
BACKGROUND The overdose epidemic has been exacerbated by a dramatic increase in deaths involving illicitly manufactured fentanyl (IMF). Drug checking is a novel strategy to identify IMF in illicit drugs. We examined the uptake and acceptability of rapid fentanyl test strips among young adults. METHODS From May to September 2017, we recruited 93 young adults in Rhode Island who reported injecting drugs or using heroin, cocaine, or illicitly obtained prescription pills in the past 30 days. Participants were asked to test either their urine after drug use (post-consumption) or a drug sample prior to use (pre-consumption) using rapid fentanyl test strips. After a questionnaire and a brief training, participants received ten strips for their personal use and were asked to return for a one-month follow-up visit, which assessed the uptake and acceptability of the rapid strips tests and the behavioral outcomes associated with receipt of a positive test. RESULTS Of the 81 (87%) participants who returned for follow-up and who had complete data, the mean age was 27, 45 (56%) were male, and 37 (46%) were non-white. A total of 62 participants (77%) reported using at least one test strip. Of these, 31 (50%) received at least one positive result. A positive result was associated with older age, homelessness, heroin use, injection drug use, ever witnessing an overdose, and concern about overdose or drugs being laced with fentanyl (all p < 0.05). Receiving a positive result was significantly associated with reporting a positive change in overdose risk behavior between baseline and follow-up (p ≤ 0.01). Among all participants, 79 (98%) reported confidence in their ability to use the test strips and 77 (95%) wanted to use them in the future. CONCLUSIONS Young adults reported high uptake and acceptability of fentanyl test strips to detect IMF in illicit drugs.
Collapse
|
55
|
Gjerde H, Clausen GB, Andreassen E, Furuhaugen H. Evaluation of Dräger DrugTest 5000 in a Naturalistic Setting. J Anal Toxicol 2018; 42:248-254. [PMID: 29409046 DOI: 10.1093/jat/bky003] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Indexed: 12/15/2022] Open
Abstract
Reliable field testing devices for psychoactive drugs would be useful tools for the police for detecting drug-impaired drivers. The Norwegian Mobile Police Service (NMPS) started using Dräger DrugTest 5000 (DDT5000) in 2015 as an on-site screening instrument for drugs in samples of oral fluid. The aim of this study was to compare the results of field testing of DDT5000 with drug findings in blood and oral fluid samples taken from drivers suspected for driving under the influence of drugs (DUID). In total, 369 drivers were included in this field testing; blood samples were obtained from all of them, while oral fluid samples were collected with the Intercept device from 301 of them. The median time from field testing with DDT5000 and collection of blood and oral fluid samples was 50 min. The proportions of false positive results with DDT5000 compared to findings in blood samples above the Norwegian legal per se limits were for cannabis 14.5%, amphetamine 23.2%, methamphetamine 38.4%, cocaine 87.1%, opiates 65.9% and benzodiazepines 36.4%. The proportions of false negatives were for cannabis 13.4%, amphetamine 4.9%, methamphetamine 6.1%, cocaine 0.0%, opiates 0.0% and benzodiazepines 18.8%. Among drivers who had drug concentrations above the legal limits in blood, the proportion who tested positive using DDT5000 was 82.9% for THC, 90.8% for amphetamine, 75.7% for methamphetamine, 100.0% for cocaine, 100.0% for opiates and 37.2% for benzodiazepines. In cases with false-positive DDT5000 results compared to blood, traces of drugs were most often found in oral fluid. The DDT5000 did not absolutely correctly identify DUID offenders due to fairly large proportions of false-positive or false-negative results compared to drug concentrations in blood. The police reported that DDT5000 was still a valuable tool in identifying possible DUID offenders, resulting in more than doubling the number of apprehended DUID offenders.
Collapse
|
56
|
Cao J, Du Y, Wang YJ, Wu B, Jia J, Wei ZW, Yun KM, Liang W, Wang YY, Sun JH. Pharmacokinetics of meperidine (pethidine) in rabbit oral fluid: correlation with plasma concentrations after controlled administration. DIE PHARMAZIE 2018; 73:324-328. [PMID: 29880084 DOI: 10.1691/ph.2018.8014] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Oral fluid assays for quantifying drugs are useful in forensic toxicology and drug monitoring. Compared with blood and urine specimens, oral fluid collection is simple, non-invasive, and more difficult to adulterate. Therefore, we investigated whether meperidine and its metabolites could be detected in oral fluid and whether there was a predictable relationship between oral fluid and plasma concentrations. Male New Zealand white rabbits (n = 10) were administered meperidine hydrochloride (20 mg/kg, intravenous). Then, plasma and oral fluid were collected at various time points up to 10 h after administration. We developed a simple and sensitive gas chromatography-mass spectrometry method for the determination of meperidine and normeperidine in oral fluid and plasma. We estimated the apparent pharmacokinetic parameters for meperidine in oral fluid and plasma and determined the ratio and correlation between oral fluid and plasma concentrations. The results demonstrate that this method has excellent specificity, linearity, precision, and recovery. Meperidine and normeperidine were detected in both body fluids; meperidine was the most abundant analyte in oral fluid. The oral fluid-to-plasma drug concentration ratios did not differ significantly over time (p > 0.05). In addition, oral fluid and plasma levels of meperidine and normeperidine were significantly correlated over time (r = 0.713 and 0.725, respectively; p < 0.05). These results provide context for interpreting meperidine and metabolite concentrations in oral fluid and support the utility of oral fluid as an alternative matrix in clinical and forensic testing.
Collapse
|
57
|
Hill R, Dewey WL, Kelly E, Henderson G. Oxycodone-induced tolerance to respiratory depression: reversal by ethanol, pregabalin and protein kinase C inhibition. Br J Pharmacol 2018; 175:2492-2503. [PMID: 29574756 PMCID: PMC5980627 DOI: 10.1111/bph.14219] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Revised: 03/08/2018] [Accepted: 03/13/2018] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND AND PURPOSE Oxycodone, a prescription opioid, is a major drug of abuse, especially in the USA, and contributes significantly to opioid overdose deaths each year. Overdose deaths result primarily from respiratory depression. We have studied respiratory depression by oxycodone and have characterized how tolerance develops on prolonged exposure to the drug. We have investigated the role of PKC in maintaining tolerance and have examined whether ethanol or pregabalin reverses oxycodone-induced tolerance. EXPERIMENTAL APPROACH Respiration was measured in male CD-1 mice by whole-body plethysmography. Mice were preinjected with oxycodone then implanted with mini-pumps (s.c.) delivering 20, 45 or 120 mg·kg-1 ·day-1 oxycodone for 6 days and subsequently challenged with oxycodone (3 mg·kg-1 , i.p.) or morphine (10 mg·kg-1 , i.p.) to assess the level of tolerance. KEY RESULTS Oxycodone-treated mice developed tolerance to oxycodone and cross tolerance to morphine-induced respiratory depression. Tolerance was less with 20 mg·kg-1 ·day-1 than with 45 or 120 mg·kg-1 ·day-1 oxycodone treatment. At doses that do not depress respiration, ethanol (0.3 g·kg-1 ), pregabalin (20 mg·kg-1 ) and calphostin C (45 μg·kg-1 ) all reversed oxycodone-induced tolerance resulting in significant respiratory depression. Reversal of tolerance was less in mice treated with oxycodone (120 mg·kg-1 ·day-1 ). In mice receiving ethanol and calphostin C or ethanol and pregabalin, there was no greater reversal of tolerance than seen with either drug alone. CONCLUSION AND IMPLICATIONS These data suggest that oxycodone-induced tolerance is mediated by PKC and that reversal of tolerance by ethanol or pregabalin may be a contributory factor in oxycodone overdose deaths.
Collapse
|
58
|
Baldwin N, Gray R, Goel A, Wood E, Buxton JA, Rieb LM. Fentanyl and heroin contained in seized illicit drugs and overdose-related deaths in British Columbia, Canada: An observational analysis. Drug Alcohol Depend 2018; 185:322-327. [PMID: 29486421 PMCID: PMC5889734 DOI: 10.1016/j.drugalcdep.2017.12.032] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2017] [Revised: 12/04/2017] [Accepted: 12/05/2017] [Indexed: 10/18/2022]
Abstract
BACKGROUND Due to the alarming rise in opioid-related overdose deaths, a public health emergency was declared in British Columbia (BC). In this study, we examined the relationship between illicit fentanyl and heroin found in seized drugs and illicit overdose deaths in BC. METHODS An observational cross-sectional survey was conducted using BC data from Health Canada's Drug Analysis Service, which analyzes drug samples seized by law enforcement agencies, and non-intentional illicit overdoses from the BC Coroner's Service, from 2000 to 2016. Initial scatter plots and subsequent multivariate regression analysis were performed to describe the potential relationship between seized illicit fentanyl samples and overdose deaths and to determine if this differed from seized heroin and overdose deaths. Fentanyl samples were analyzed for other drug content. RESULTS Fentanyl is increasingly being found combined with other opioid and non-opioid illicit drugs. Strong positive relationships were found between the number of seized fentanyl samples and total overdose deaths (R2 = 0.97) as well as between seized fentanyl and fentanyl-detected overdose deaths (R2 = 0.99). A positive association was found between the number of seized heroin samples and total overdose deaths (R2 = 0.78). CONCLUSION This research contributes to the expanding body of evidence implicating illicit fentanyl use (often combined with heroin or other substances) in overdose deaths in BC. Policy makers and healthcare providers are urged to implement drug treatment and harm reduction strategies for people at risk of overdose associated with current trends in illicit opioid use.
Collapse
|
59
|
Krieger MS, Yedinak JL, Buxton JA, Lysyshyn M, Bernstein E, Rich JD, Green TC, Hadland SE, Marshall BDL. High willingness to use rapid fentanyl test strips among young adults who use drugs. Harm Reduct J 2018; 15:7. [PMID: 29422052 PMCID: PMC5806485 DOI: 10.1186/s12954-018-0213-2] [Citation(s) in RCA: 79] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2017] [Accepted: 02/01/2018] [Indexed: 01/01/2023] Open
Abstract
BACKGROUND Synthetic opioid overdose mortality among young adults has risen more than 300% in the USA since 2013, primarily due to the contamination of heroin and other drugs with illicitly manufactured fentanyl. Rapid test strips, which can be used to detect the presence of fentanyl in drug samples (before use) or urine (after use), may help inform people about their exposure risk. The purpose of this study was to determine whether young adults who use drugs were willing to use rapid test strips as a harm reduction intervention to prevent overdose. We hypothesized that those who had ever overdosed would be more willing to use the test strips. METHODS We recruited a convenience sample of young adults who use drugs in Rhode Island from May to September 2017. Eligible participants (aged 18 to 35 with past 30-day drug use) completed an interviewer-administered survey. The survey assessed participant's socio-demographic and behavioral characteristics, overdose risk, as well as suspected fentanyl exposure, and willingness to use take-home rapid test strips to detect fentanyl contamination in drugs or urine. Participants were then trained to use the test strips and were given ten to take home. RESULTS Among 93 eligible participants, the mean age was 27 years (SD = 4.8), 56% (n = 52) of participants were male, and 56% (n = 52) were white. Over one third (n = 34, 37%) had a prior overdose. The vast majority (n = 86, 92%) of participants wanted to know if there was fentanyl in their drug supply prior to their use. Sixty-five (70%) participants reported concern that their drugs were contaminated with fentanyl. After the brief training, nearly all participants (n = 88, 95%) reported that they planned to use the test strips. CONCLUSIONS More than 90% of participants reported willingness to use rapid test strips regardless of having ever overdosed, suggesting that rapid fentanyl testing is an acceptable harm reduction intervention among young people who use drugs in Rhode Island. Study follow-up is ongoing to determine whether, how, and under what circumstances participants used the rapid test strips and if a positive result contributed to changes in overdose risk behavior.
Collapse
|
60
|
Schedules of Controlled Substances: Temporary Placement of Cyclopropyl Fentanyl in Schedule I. Temporary amendment; temporary scheduling order. FEDERAL REGISTER 2018; 83:469-472. [PMID: 29319947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The Administrator of the Drug Enforcement Administration is issuing this temporary scheduling order to schedule the synthetic opioid, -(1-phenethylpiperidin-4-yl)-N-phenylcyclopropanecarboxamide (cyclopropyl fentanyl), and its isomers, esters, ethers, salts, and salts of isomers, esters, and ethers in schedule I. This action is based on a finding by the Administrator that the placement of cyclopropyl fentanyl in schedule I of the Controlled Substances Act is necessary to avoid an imminent hazard to the public safety. As a result of this order, the regulatory controls and administrative, civil, and criminal sanctions applicable to schedule I controlled substances will be imposed on persons who handle (manufacture, distribute, reverse distribute, import, export, engage in research, conduct instructional activities or chemical analysis, or possess), or propose to handle, cyclopropyl fentanyl.
Collapse
|
61
|
Griswold MK, Chai PR, Krotulski AJ, Friscia M, Chapman BP, Varma N, Boyer EW, Logan BK, Babu KM. A Novel Oral Fluid Assay (LC-QTOF-MS) for the Detection of Fentanyl and Clandestine Opioids in Oral Fluid After Reported Heroin Overdose. J Med Toxicol 2017; 13:287-292. [PMID: 28971325 PMCID: PMC5711761 DOI: 10.1007/s13181-017-0632-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Revised: 09/08/2017] [Accepted: 09/14/2017] [Indexed: 10/18/2022] Open
Abstract
INTRODUCTION The adulteration of heroin with non-pharmaceutical fentanyl and other high-potency opioids is one of the factors contributing to striking increases in overdose deaths. To fully understand the magnitude of this problem, accurate detection methods for fentanyl and other novel opioid adulterant exposures are urgently required. The objective of this work was to compare the detection of fentanyl in oral fluid and urine specimens using liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) in a population of heroin users presenting to the Emergency Department after overdose. METHODS This was a prospective observational study of adult Emergency Department patients who presented after a reported heroin overdose requiring naloxone administration. Participants provided paired oral fluid and urine specimens, which were prepared, extracted, and analyzed using a dual LC-QTOF-MS workflow for the identification of traditional and emerging drugs of abuse. Analytical instrumentation included SCIEX TripleTOF® 5600+ and Waters Xevo® G2-S QTOF systems. RESULTS Thirty participants (N = 30) were enrolled during the study period. Twenty-nine participants had fentanyl detected in their urine, while 27 had fentanyl identified in their oral fluid (overall agreement 93.3%, positive percent agreement 93.1%). Cohen's Kappa (k) was calculated and demonstrated moderately, significant agreement (k = 0.47; p value 0.002) in fentanyl detection between oral fluid and urine using this LC-QTOF-MS methodology. Additional novel opioids and metabolites, including norfentanyl, acetylfentanyl, and U-47700, were detected during this study. CONCLUSION In this study of individuals presenting to the ED after reported heroin overdose, a strikingly high proportion had a detectable fentanyl exposure. Using LC-QTOF-MS, the agreement between paired oral fluid and urine testing for fentanyl detection indicates a role for oral fluid testing in surveillance for nonpharmaceutical fentanyl. Additionally, the use of LC-QTOF-MS allowed for the detection of other clandestine opioids (acetylfentanyl and U-47700) in oral fluid.
Collapse
|
62
|
de Bruijn P, Kuip EJM, Lam MH, Mathijssen RHJ, Koolen SLW. Bioanalytical methods for the quantification of hydromorphone, fentanyl, norfentanyl, morphine, morphine-3ß-glucuronide and morphine-6ß-glucuronide in human plasma. J Pharm Biomed Anal 2017; 149:475-481. [PMID: 29182997 DOI: 10.1016/j.jpba.2017.11.035] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Revised: 11/10/2017] [Accepted: 11/11/2017] [Indexed: 11/17/2022]
Abstract
The aim of this study was to develop an assay for the quantification of hydromorphone, morphine, fentanyl and the metabolites norfentanyl, morphine-3ß-glucuronide and morphine-6ß-glucuronide in human plasma to support pharmacokinetic studies investigating the large interpatient variability in response to opioid treatment. For the quantitation of hydromorphone, morphine, fentanyl and its metabolite norfentanyl aliquots of 200μL human potassium EDTA plasma were deproteinized with deuterated internal standards in a mixture of acetonitrile and acetone, followed by a liquid-liquid extraction with 4% ammonium hydroxide and ethyl acetate. Morphine-3ß-glucuronide and morphine-6ß-glucuronide were extracted by a solid phase extraction using 10mM ammonium carbonate pH 8.8 and a deuterated internal standards solution. Morphine, hydromorphone, fentanyl and norfentanyl were separated on an Aquity UPLC® BEH C18 column 1.7μm, 100mm×2.1mm at 50°C. Separation, was achieved on a gradient of methanol with an overall run time of 6min. The compounds were quantified by triple-quadrupole mass spectrometry in the positive ion electrospray ionization mode. Morphine-3ß-glucuronide and morphine-6ß-glucuronide were separated on a VisionHT C18-P; 3μm 2.1×50mm, column at 40°C on a gradient of acetonitrile, with an overall run time of 10min. Both methods were precise and accurate, with within-run and between-run precisions within acceptable limits and accuracy ranging from 84.0 to 105.5%. The methods were successfully applied to support clinical pharmacological studies in patients treated with opioids for the treatment of moderate to severe cancer-related pain.
Collapse
|
63
|
Fabregat-Safont D, Carbón X, Ventura M, Fornís I, Guillamón E, Sancho JV, Hernández F, Ibáñez M. Updating the list of known opioids through identification and characterization of the new opioid derivative 3,4-dichloro-N-(2-(diethylamino)cyclohexyl)-N-methylbenzamide (U-49900). Sci Rep 2017; 7:6338. [PMID: 28740128 PMCID: PMC5524693 DOI: 10.1038/s41598-017-06778-9] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2017] [Accepted: 06/16/2017] [Indexed: 01/22/2023] Open
Abstract
New psychoactive substances have been rapidly growing in popularity in the drug market as non-illegal drugs. In the last few years, an increment has been reported on the use of synthetic alternatives to heroin, the synthetic opioids. Based on the information provided by the European Monitoring Centre for Drug and Drug Addiction, these synthetic opioids have been related to overdoses and deaths in Europe and North America. One of these opioids is the U-47700. A few months ago, U-47700 was scheduled in the U.S. and other countries, and other opioid derivatives have been appearing in order to replace it. One of these compounds is U-49900, an analog of U-47700. A white powder sample was obtained from an anonymous user in Spain. After an accurate characterization by gas chromatography-mass spectrometry, ultra-high performance liquid chromatography-high resolution mass spectrometry, nuclear magnetic resonance and single-crystal X-ray diffraction; and complemented by Fourier-transformed infrared spectroscopy, ultraviolet and circular dichroism spectrophotometry, the drug sample was unequivocally identified as U-49900. The information provided will be useful for the Early Warning System and forensic laboratories for future identifications of the U-49900, as well as in tentative identifications of other related opioids.
Collapse
|
64
|
Gill JR. From Death to Death Certificate: What do the Dead say? J Med Toxicol 2017; 13:111-116. [PMID: 27139707 PMCID: PMC5330954 DOI: 10.1007/s13181-016-0551-y] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2016] [Revised: 03/31/2016] [Accepted: 04/13/2016] [Indexed: 10/21/2022] Open
Abstract
This is an overview of medicolegal death investigation and death certification. Postmortem toxicological analysis, particularly for ethanol and drugs of abuse, plays a large role in the forensic investigation of natural and unnatural deaths. Postmortem drug concentrations must be interpreted in light of the autopsy findings and circumstances. Interpretations of drug and ethanol concentrations are important for death certification, but they also may be important for other stakeholders such as police, attorneys, public health practitioners, and the next-of-kin.
Collapse
|
65
|
Concheiro M, Lendoiro E, de Castro A, Gónzalez-Colmenero E, Concheiro-Guisan A, Peñas-Silva P, Macias-Cortiña M, Cruz-Landeira A, López-Rivadulla M. Bioanalysis for cocaine, opiates, methadone, and amphetamines exposure detection during pregnancy. Drug Test Anal 2016; 9:898-904. [PMID: 27595432 DOI: 10.1002/dta.2087] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2016] [Revised: 09/01/2016] [Accepted: 09/01/2016] [Indexed: 01/13/2023]
Abstract
Drug exposure during pregnancy constitutes a major legal issue and a public health concern. Drug and metabolite determination in biological matrices from mother and newborn is an objective indication of prenatal drug exposure. However, limited data are available regarding the interpretation of these analytical results in terms of window of detection and degree of exposure. We collected paired maternal hair, meconium, placenta, and umbilical cord from 727 mother-newborn dyads. We analyzed these specimens by liquid chromatography-tandem mass spectrometry for the determination of cocaine, opioids, methadone, and amphetamines, and compared the analytical results from the four different matrices. The cases were divided in non-exposure, low, and frequent exposure, based on maternal hair concentrations and segmental analysis by trimesters. For cocaine, 62 cases tested positive in hair, 9 in meconium, 6 in placenta and 7 in umbilical cord. In the case of opioids, 14 maternal hair cases were positive, 11 meconium and umbilical cord and 9 placenta samples. For methadone, 11 cases were positive in hair, 9 in meconium and 6 in placenta and umbilical cord. For amphetamines, 18 cases were positive according to maternal hair, but all meconium, placenta, and umbilical cord tested negative. Maternal hair was the most sensitive specimen to detect drug exposure during pregnancy. Meconium, placenta, and umbilical cord tested positive if hair concentrations showed frequent drug use during the whole pregnancy, especially during the third trimester. Meconium, placenta, and umbilical cord also tested positive for morphine and metabolites, if this drug was administered during labour and delivery. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
|
66
|
Krizman I, Senta I, Ahel M, Terzic S. Wastewater-based assessment of regional and temporal consumption patterns of illicit drugs and therapeutic opioids in Croatia. THE SCIENCE OF THE TOTAL ENVIRONMENT 2016; 566-567:454-462. [PMID: 27232972 DOI: 10.1016/j.scitotenv.2016.05.075] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2016] [Revised: 04/29/2016] [Accepted: 05/12/2016] [Indexed: 06/05/2023]
Abstract
A comprehensive study of spatial and temporal consumption patterns of the selected illicit drugs (heroin, cocaine, amphetamine, MDMA, methamphetamine, cannabis) and therapeutic opioids (codeine, methadone) has been performed in six Croatian cities by applying wastewater-based epidemiology. The investigated cities (Bjelovar, Vinkovci, Varazdin, Karlovac, Zadar and Zagreb) varied widely in the population size (27,000-688,000 inhabitants) as well as in the number of registered drug consumers included in compulsory and voluntary medical treatment and rehabilitation programs (30-513 persons/100,000 inhabitants of age 15-64). The most consumed illicit drugs were cannabis (10-70doses/day/1000 inhabitants), heroin (<0.2-10doses/day/1000 inhabitants) and cocaine (0.2-8.7doses/day/1000 inhabitants), while the consumption of amphetamine-type drugs was much lower (<0.01-4.4doses/day/1000 inhabitants). Enhanced consumption of illegal drugs was generally associated with larger urban centers (Zagreb and Zadar) however comparatively high consumption rate of cocaine, MDMA and methadone was determined in some smaller cities as well. The overall average dose number of 3 major illegal stimulants (cocaine, MDMA, amphetamine) was rather similar to the number of corresponding heroin doses, which is in disagreement with a comparatively much higher proportion of heroin users in the total number of registered drug users in Croatia. Furthermore, the illicit drug consumption pattern in the large continental city (Zagreb) was characterized by a significant enhancement of the consumption of all stimulants during the weekend, which could not be confirmed neither for the coastal city of Zadar nor for the remaining small continental cities. On the other hand, the city of Zadar exhibited a significant increase of stimulant drug usage during summer vacation period, as a result of pronounced seasonal changes of the population composition and lifestyle in coastal tourist centers. The obtained results represent a valuable complementary data source for the optimisation and implementation of strategies to combat drug abuse in Croatia.
Collapse
|
67
|
Tscharke BJ, Chen C, Gerber JP, White JM. Temporal trends in drug use in Adelaide, South Australia by wastewater analysis. THE SCIENCE OF THE TOTAL ENVIRONMENT 2016; 565:384-391. [PMID: 27179320 DOI: 10.1016/j.scitotenv.2016.04.183] [Citation(s) in RCA: 88] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Revised: 04/26/2016] [Accepted: 04/26/2016] [Indexed: 04/14/2023]
Abstract
Analysis of municipal wastewater for drug metabolites can reveal the scale of drug use within communities. An Australian city with a population of 1.2million inhabitants was assessed for 4 stimulants: cocaine, methamphetamine, 3.4-methylenedioxymethamphetamine (MDMA) and amphetamine; 6 opioids: codeine, morphine, heroin, fentanyl, oxycodone and methadone; 11 new psychoactive substances (NPS); benzylpiperazine (BZP), trifluoromethylphenylpiperazine (TFMPP), methcathinone, methylone, mephedrone, methylenedioxypyrovalerone (MDPV), alpha pyrrolidinopentiophenone (alpha-PVP), paramethoxyamphetamine (PMA), 25C-NBOMe, 25B-NBOMe, 25I-NBOMe; and cannabis, for up to four years between December 2011 and December 2015. Temporal trends revealed increasing usage rates of methamphetamine, cocaine, oxycodone, and fentanyl, while decreasing rates of use were observed for MDMA, BZP and methylone. Use of other opioids and cannabis was generally stable across years, while use of new psychoactive substances fluctuated without an apparent direction. Opioids and cannabis were used at a consistent level through the course of the week, while use of stimulants and some NPS increased on the weekend. Seasonal differences in use were observed for MDMA and cannabis (p$_amp_$lt;0.05) where, on average, MDMA use was approximately 90% higher in December than in other months and cannabis use was approximately 45% lower in each February. Residual month-to-month variability measures on trend-free data showed NPS use had higher variability than the stimulants and opioids. Frequent wastewater sampling and analysis over prolonged periods has yielded valuable insights into long-term drug use trends, in some instances revealed important within-year trends, and demonstrated the differing patterns of use of drugs on weekends compared to weekdays.
Collapse
|
68
|
Thomas SP, Sankar HKN. A simple colorimetric method for estimation of tramadol hydrochloride in pure and tablet dosage forms. Indian J Pharmacol 2016; 48:550-554. [PMID: 27721542 PMCID: PMC5051250 DOI: 10.4103/0253-7613.190746] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Accepted: 08/04/2016] [Indexed: 11/09/2022] Open
Abstract
OBJECTIVE The objective of this study was to develop and validate a simple method for estimation of tramadol hydrochloride (TH) in pure and pharmaceutical dosage forms using a colorimeter. MATERIALS AND METHODS TH on reaction with Eriochrome Black T in the presence of acetate buffer at pH 3.5 forms a colored complex. This complex was extracted with a fixed volume of chloroform. The optical density of this colored complex was measured against reagent blank using a colorimeter at 520 nm. RESULTS Beer's law was obeyed with a good correlation coefficient (0.999) in the concentration range of 2.5 μg/ml to 10 μg/ml. Drug content estimation and recovery studies carried out on commercial tablet dosage forms demonstrated the accuracy of the method and that excipients do not cause interference. Precision and robustness were measured and found to be acceptable (% relative standard deviation <2%). CONCLUSION The proposed method can be used for the rapid determination of TH content in tablets at a health-care provider level using already available staff and equipment.
Collapse
|
69
|
Roy É, Arruda N, Bertrand K, Dufour M, Laverdière É, Jutras-Aswad D, Perreault M, Berbiche D, Bruneau J. Prevalence and correlates of prescription opioid residue injection. Drug Alcohol Depend 2016; 166:69-74. [PMID: 27397582 DOI: 10.1016/j.drugalcdep.2016.06.025] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2016] [Revised: 06/17/2016] [Accepted: 06/23/2016] [Indexed: 01/04/2023]
Abstract
BACKGROUND There is growing evidence of intravenous administration of prescription opioids (POs) in several countries. Preparation of POs for injection may leave residues in containers and filters used by people who inject drugs and may lead to adverse health outcomes if they are injected. METHODS This exploratory study used cross-sectional data from the COSMO study, a prospective cohort of out-of-treatment cocaine users carried out in Montréal (Canada) between October 2010 and August 2015. For this analysis, only one visit per participant was selected, that is, the first time the participant reported PO injection during the study. The outcome of interest, "injection of PO residues", was defined as having injected PO residues from a filter and/or a container in the last month. Correlates of this outcome were identified using logistic regression analyses. RESULTS Of the 122 participants who reported PO injection during the study period, 41.8% had injected PO residues. Reporting an unstable source of income (AOR=4.26; 95% CI: 1.03-17.69), a recent overdose (AOR=5.45; 95% CI: 1.50-19.88) and a preponderant use of opiates (mostly opiate use versus other drugs excluding alcohol and cannabis) (AOR=2.46; 95% CI: 1.08-5.63) increased the risk of PO residue injection. The odds of reporting PO residue injection rose by 7% per unit increase in the score of psychological distress (AOR=1.07 per unit increase; 95% CI: 1.01-1.12). CONCLUSIONS The findings of this study suggest that PO residue injection is associated with markers of vulnerability. Further investigation is needed in order to better understand this understudied drug injection practice.
Collapse
|
70
|
Thai PK, Lai FY, Bruno R, van Dyken E, Hall W, O'Brien J, Prichard J, Mueller JF. Refining the excretion factors of methadone and codeine for wastewater analysis - Combining data from pharmacokinetic and wastewater studies. ENVIRONMENT INTERNATIONAL 2016; 94:307-314. [PMID: 27295047 DOI: 10.1016/j.envint.2016.05.033] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2016] [Revised: 05/09/2016] [Accepted: 05/31/2016] [Indexed: 06/06/2023]
Abstract
Analysing drug residues in wastewater (wastewater analysis) to monitor the consumption of those drugs in the population has become a complementary method to epidemiological surveys. In this method, the excretion factor of a drug (or the percentage of drug metabolites excreted through urine) is a critical parameter for the back-estimation of the consumption of a drug. However, this parameter is usually derived from a small database of human pharmacokinetic studies. This is true for methadone and codeine, the two most commonly used opioids and also common substances of abuse. Therefore, we aimed to refine the current excretion factors used for estimating methadone and codeine by analysing published data from the literature on the excretion of methadone, its main metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), and codeine. Our review included both human drug pharmacokinetic studies and wastewater analysis studies. We found that while the commonly used excretion factor of methadone (~27.5%) was relatively accurate, the excretion factor of EDDP, a better biomarker for methadone consumption in sewer epidemiology, should be twice that of methadone (i.e. 55%) instead of the current equal or half values. For codeine, the excretion factor should be ~30% instead of 63.5% or 10% as previously used in wastewater analysis studies. Data from wastewater analysis studies could be used in this way to refine the excretion factors of the drugs of interest.
Collapse
|
71
|
Naylor CH, Kybert NJ, Schneier C, Xi J, Romero G, Saven JG, Liu R, Charlie Johnson AT. Scalable Production of Molybdenum Disulfide Based Biosensors. ACS NANO 2016; 10:6173-9. [PMID: 27227361 PMCID: PMC4949953 DOI: 10.1021/acsnano.6b02137] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
We demonstrate arrays of opioid biosensors based on chemical vapor deposition grown molybdenum disulfide (MoS2) field effect transistors (FETs) coupled to a computationally redesigned, water-soluble variant of the μ-opioid receptor (MOR). By transferring dense films of monolayer MoS2 crystals onto prefabricated electrode arrays, we obtain high-quality FETs with clean surfaces that allow for reproducible protein attachment. The fabrication yield of MoS2 FETs and biosensors exceeds 95%, with an average mobility of 2.0 cm(2) V(-1) s(-1) (36 cm(2) V(-1) s(-1)) at room temperature under ambient (in vacuo). An atomic length nickel-mediated linker chemistry enables target binding events that occur very close to the MoS2 surface to maximize sensitivity. The biosensor response calibration curve for a synthetic opioid peptide known to bind to the wild-type MOR indicates binding affinity that matches values determined using traditional techniques and a limit of detection ∼3 nM (1.5 ng/mL). The combination of scalable array fabrication and rapid, precise binding readout enabled by the MoS2 transistor offers the prospect of a solid-state drug testing platform for rapid readout of the interactions between novel drugs and their intended protein targets.
Collapse
|
72
|
Anacardio R, Bartolini S, Gentile MM, Bagnasco M, Carlucci G. HPLC Investigated Physicochemical Compatibility between Artrosilene® Injectable Solution and other Pharmaceutical Products Frequently Used for Combined Therapy into Elastomeric Baxter LV5 Infusion Devices. Int J Immunopathol Pharmacol 2016; 18:791-8. [PMID: 16388729 DOI: 10.1177/039463200501800423] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Ketoprofen lysine salt (Artrosilene®, injectable solution) is a non-steroidal anti-inflammatory agent frequently administered by slow intravenous infusion with portable elastomeric infusion systems in association regimen with other analgesic drugs. The aim of this study was to investigate the physicochemical compatibility between ketoprofen lysine salt (Artrosilene®, injectable solution) and other injectable drugs frequently used in association, such as tramadol hydrochloride, keterolac tromethamine and morphine hydrochloride, into the Infusor LV5, Baxter elastomeric infusion system. Physicochemical properties of drug mixture, including colour, clarity, pH and drug content were observed or measured by a reversed-phase HPLC method with UV detection, before and after (up to 7 days) mixing at room temperature and under light protection. The results obtained demonstrated the physicochemical compatibility of ketoprofen lysine salt (Artrosilene®, injectable solution) with all drug formulations at every tested mixing ratios into Baxer Infusor LV5 infusion devices.
Collapse
|
73
|
Glavanović S, Glavanović M, Tomišić V. Simultaneous quantitative determination of paracetamol and tramadol in tablet formulation using UV spectrophotometry and chemometric methods. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2016; 157:258-264. [PMID: 26774813 DOI: 10.1016/j.saa.2015.12.020] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2015] [Revised: 11/20/2015] [Accepted: 12/17/2015] [Indexed: 06/05/2023]
Abstract
The UV spectrophotometric methods for simultaneous quantitative determination of paracetamol and tramadol in paracetamol-tramadol tablets were developed. The spectrophotometric data obtained were processed by means of partial least squares (PLS) and genetic algorithm coupled with PLS (GA-PLS) methods in order to determine the content of active substances in the tablets. The results gained by chemometric processing of the spectroscopic data were statistically compared with those obtained by means of validated ultra-high performance liquid chromatographic (UHPLC) method. The accuracy and precision of data obtained by the developed chemometric models were verified by analysing the synthetic mixture of drugs, and by calculating recovery as well as relative standard error (RSE). A statistically good agreement was found between the amounts of paracetamol determined using PLS and GA-PLS algorithms, and that obtained by UHPLC analysis, whereas for tramadol GA-PLS results were proven to be more reliable compared to those of PLS. The simplest and the most accurate and precise models were constructed by using the PLS method for paracetamol (mean recovery 99.5%, RSE 0.89%) and the GA-PLS method for tramadol (mean recovery 99.4%, RSE 1.69%).
Collapse
|
74
|
Stoddard KI, Huggett DB. Wastewater Effluent Hydrocodone Concentrations as an Indicator of Drug Disposal Program Success. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY 2015; 95:139-144. [PMID: 26067702 DOI: 10.1007/s00128-015-1574-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2014] [Accepted: 06/04/2015] [Indexed: 06/04/2023]
Abstract
Drug disposal programs have been seen as a remedy to the concern of environmental contamination resulting from pharmaceutical disposal down the toilet or sink; however a thorough review of peer-reviewed literature and publicly available information on these programs indicates limited research has been conducted to validate the effectiveness of these programs at reducing pharmaceuticals in the environment. The purpose of this research was to determine if drug disposal programs could actually reduce pharmaceutical residues in the environment. The concentration of hydrocodone in wastewater effluent released from a wastewater treatment plant in Denton, Texas was monitored before and after a take back program called Denton Drug Disposal Day (D4). Data collected and analyzed suggests D4 events were successful in contributing to a reduction of pharmaceutical loading to the environment; however there was insufficient evidence to demonstrate that D4 events were exclusively responsible for these improvements.
Collapse
|
75
|
Fields MD, Abate MA, Hu L, Long DL, Blommel ML, Haikal NA, Kraner JC. Parent and Metabolite Opioid Drug Concentrations in Unintentional Deaths Involving Opioid and Benzodiazepine Combinations. J Forensic Sci 2015; 60:950-6. [PMID: 26223761 PMCID: PMC4944848 DOI: 10.1111/1556-4029.12807] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2013] [Revised: 04/28/2014] [Accepted: 05/12/2014] [Indexed: 11/29/2022]
Abstract
Effects of benzodiazepines on postmortem opioid parent and parent/metabolite blood concentration ratios were determined for fentanyl-, hydrocodone-, methadone-, or oxycodone-related accidental deaths. These opioids are partially metabolized by the CYP3A4 enzyme system, which is also affected by diazepam and alprazolam. Opioid/metabolite combinations examined were as follows: fentanyl/norfentanyl, hydrocodone/dihydrocodeine, methadone/EDDP, and oxycodone/oxymorphone. Parent opioid concentrations were analyzed for 877 deaths. Parent/metabolite concentration ratios were analyzed for 349 deaths, excluding cases with co-intoxicants present known to interfere with opioid elimination. Alprazolam in combination with diazepam significantly decreased median hydrocodone concentrations by 48% (p = 0.01) compared to hydrocodone alone. The methadone parent/metabolite concentration ratio was reduced by 35% in the presence of diazepam compared to methadone alone (p = 0.03). Benzodiazepines did not statistically significantly affect fentanyl or oxycodone concentrations. Possible factors affecting opioid concentrations and possible toxicity development, including any differential effects on specific opioids, should continue to be explored.
Collapse
|