2101
|
Coffey CC, Pearce TA, Lawrence RB, Hudnall JB, Slaven JE, Martin SB. Measurement capability of field portable organic vapor monitoring instruments under different experimental conditions. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2009; 6:1-8. [PMID: 18949604 DOI: 10.1080/15459620802514728] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
The performance of field portable direct-reading organic vapor monitors (DROVMs) was evaluated under a variety of experimental conditions. Four of the DROVMs had photoionization detectors (ppbRAE, IAQRAE, MultiRAE, and Century Toxic Vapor Analyzer), one had a flame ionization detector (Century Toxic Vapor Analyzer), and one was a single-beam infrared spectrophotometer (SapphIRe). Four of each DROVM (two Century Toxic Vapor Analyzers and SapphIRes) were tested. The DROVMs were evaluated at three temperatures (4 degrees C, 21 degrees C, and 38 degrees C), three relative humidities (30%, 60%, and 90%), and two hexane concentrations (5 ppm and 100 ppm). These conditions were selected to provide a range within the operational parameters of all the instruments. At least four replicate trials were performed across the 18 experimental conditions (3 temperatures x 3 relative humidities x 2 concentrations). To evaluate performance, the 4-hr time-weighted average readings from the DROVMs in a given trial were compared with the average of two charcoal tube concentrations using pairwise comparison. The pairwise comparison criterion was +/-25% measurement agreement between each individual DROVM and the DROVMs as a group and the average charcoal tube concentration. The ppbRAE group performed the best with 40% of all readings meeting the comparison criterion followed by the SapphIRe group at 39%. Among individual DROVMs, the best performer was a SapphIRe, with 57% of its readings meeting the criterion. The data was further analyzed by temperature, humidity, and concentration. The results indicated the performance of some DROVMs may be affected by temperature, humidity, and/or concentration. The ppbRAE group performed best at 21 degrees C with the percentage of readings meeting the criterion increasing to 63%. At the 5 ppm concentration, 44% of the ppbRAE group readings met the criterion, while at 100 ppm, only 35% did. The results indicate that monitors can be used as survey tools. Based on the data, the inconsistent performance of these DROVMs may not allow them to be used for determining compliance with occupational exposure limits.
Collapse
|
2102
|
Gallego E, Roca X, Perales JF, Guardino X. Determining indoor air quality and identifying the origin of odour episodes in indoor environments. J Environ Sci (China) 2009; 21:333-339. [PMID: 19634445 DOI: 10.1016/s1001-0742(08)62273-1] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
A methodology for identifying volatile organic compounds (VOCs) and determining air quality of indoor air has been developed. The air samples are collected using pump samplers by the inhabitants when they perceive odorous and/or discomfort episodes. Glass multi-sorbent tubes are connected to the pump samplers for the retention of VOC. The analysis is performed by automatic thermal desorption (ATD) coupled with gas chromatography-mass spectrometry (GC/MS). This methodology can be applied in cases of sick building syndrome (SBS) evaluation, in which building occupants experience a series of varied symptoms that appear to be linked to time spent in the building. Chemical pollutants concentrations (e.g., VOC) have been described to contribute to SBS. To exemplify the methodology, a qualitative determination and an evaluation of existing VOC were performed in a dwelling where the occupants experienced the SBS symptoms. Higher total VOC (TVOC) levels were detected during episodes in indoor air (1.33 +/- 1.53 mg/m3) compared to outdoor air (0.71 +/- 0.46 mg/m3). The concentrations of individual VOCs, such as ethanol, acetone, isopropanol, 1-butanol, acetic acid, acetonitrile and 1-methoxy-2-propanol, were also higher than the expected for a standard dwelling. The external source of VOC was found to be an undeclared activity of storage and manipulation of solvents located at the bottom of a contiguous building.
Collapse
|
2103
|
Shen Y, Shuai S, Wang J, Xiao J. Optimization of gasoline hydrocarbon compositions for reducing exhaust emissions. J Environ Sci (China) 2009; 21:1208-1213. [PMID: 19999967 DOI: 10.1016/s1001-0742(08)62405-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Effects of hydrocarbon compositions on raw exhaust emissions and combustion processes were studied on an engine test bench. The optimization of gasoline hydrocarbon composition was discussed. As olefins content increased from 10.0% to 25.0% in volume, the combustion duration was shortened by about 2 degree crank angle (degrees CA), and the engine-out THC emission was reduced by about 15%. On the other hand, as aromatics content changed from 35.0% to 45.0%, the engine-out NOx emissions increased by 4%. An increment in olefins content resulted in a slight increase in engine-out CO emission, while the aromatics content had little effect on engine-out total hydrocarbon (THC) and CO emissions. Over the new European driving cycle (NEDC), the THC, NOx and CO emissions of fuel with 25.0% olefins and 35.0% aromatics were about 45%, 21% and 19% lower than those of fuel with 10.0% olefins and 40.0% aromatics, respectively. The optimized gasoline compositions for new engines and new vehicles have low aromatics and high olefins contents.
Collapse
|
2104
|
Barry RC, Lin Y, Wang J, Liu G, Timchalk CA. Nanotechnology-based electrochemical sensors for biomonitoring chemical exposures. JOURNAL OF EXPOSURE SCIENCE & ENVIRONMENTAL EPIDEMIOLOGY 2009; 19:1-18. [PMID: 19018275 PMCID: PMC2909474 DOI: 10.1038/jes.2008.71] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2008] [Revised: 07/30/2008] [Accepted: 09/23/2008] [Indexed: 05/27/2023]
Abstract
The coupling of dosimetry measurements and modeling represents a promising strategy for deciphering the relationship between chemical exposure and disease outcome. To support the development and implementation of biological monitoring programs, quantitative technologies for measuring xenobiotic exposure are needed. The development of portable nanotechnology-based electrochemical (EC) sensors has the potential to meet the needs for low cost, rapid, high-throughput, and ultrasensitive detectors for biomonitoring an array of chemical markers. Highly selective EC sensors capable of pM sensitivity, high-throughput and low sample requirements (<50 microl) are discussed. These portable analytical systems have many advantages over currently available technologies, thus potentially representing the next generation of biomonitoring analyzers. This paper highlights research focused on the development of field-deployable analytical instruments based on EC detection. Background information and a general overview of EC detection methods and integrated use of nanomaterials in the development of these sensors are provided. New developments in EC sensors using various types of screen-printed electrodes, integrated nanomaterials, and immunoassays are presented. Recent applications of EC sensors for assessing exposure to pesticides or detecting biomarkers of disease are highlighted to demonstrate the ability to monitor chemical metabolites, enzyme activity, or protein biomarkers of disease. In addition, future considerations and opportunities for advancing the use of EC platforms for dosimetric studies are discussed.
Collapse
|
2105
|
Fritz BG, Mendoza DP, Gilmore TJ. Development of an electronic seepage chamber for extended use in a river. GROUND WATER 2009; 47:136-140. [PMID: 18793205 DOI: 10.1111/j.1745-6584.2008.00491.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Seepage chambers have been used to characterize the flux of water across the water-sediment interface in a variety of settings. In this work, an electronic seepage chamber was developed specifically for long-term use in a large river where hydraulic gradient reversals occur frequently with river-stage variations. A bidirectional electronic flowmeter coupled with a seepage chamber was used to measure temporal changes in the magnitude and direction of water flux across the water-sediment interface over an 8-week period. The specific discharge measured from the seepage chamber compared favorably with measurements of vertical hydraulic gradient and previous specific discharge calculations. This, as well as other supporting data, demonstrates the effectiveness of the electronic seepage chamber to accurately quantify water flux in two directions over a multimonth period in this setting. The ability to conduct multimonth measurements of water flux at a subhourly frequency in a river system is a critical capability for a seepage chamber in a system where hydraulic gradients change on a daily and seasonal basis.
Collapse
|
2106
|
Abstract
Microcantilevers based-biosensors are a new label-free technique that allows the direct detection of biomolecular interactions in a label-less way and with great accuracy by translating the biointeraction into a nanomechanical motion. Low cost and reliable standard silicon technologies are widely used for the fabrication of cantilevers with well-controlled mechanical properties. Over the last years, the number of applications of these sensors has shown a fast growth in diverse fields, such as genomic or proteomic, because of the biosensor flexibility, the low sample consumption, and the non-pretreated samples required. In this chapter, we report a dedicated design and a fabrication process of highly sensitive microcantilever silicon sensors. We will describe as well an application of the device in the environmental field showing the immunodetection of an organic toxic pesticide as an example. The cantilever biofunctionalization process and the subsequent pesticide determination are detected in real time by monitoring the nanometer-scale bending of the microcantilever due to a differential surface stress generated between both surfaces of the device.
Collapse
|
2107
|
Welch DW, Rechisky EL, Melnychuk MC, Porter AD, Walters CJ, Clements S, Clemens BJ, McKinley RS, Schreck C. Survival of migrating salmon smolts in large rivers with and without dams. PLoS Biol 2008; 6:e265. [PMID: 18959485 PMCID: PMC2573937 DOI: 10.1371/journal.pbio.0060265] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2008] [Accepted: 09/16/2008] [Indexed: 11/18/2022] Open
Abstract
The mortality of salmon smolts during their migration out of freshwater and into the ocean has been difficult to measure. In the Columbia River, which has an extensive network of hydroelectric dams, the decline in abundance of adult salmon returning from the ocean since the late 1970s has been ascribed in large measure to the presence of the dams, although the completion of the hydropower system occurred at the same time as large-scale shifts in ocean climate, as measured by climate indices such as the Pacific Decadal Oscillation. We measured the survival of salmon smolts during their migration to sea using elements of the large-scale acoustic telemetry system, the Pacific Ocean Shelf Tracking (POST) array. Survival measurements using acoustic tags were comparable to those obtained independently using the Passive Integrated Transponder (PIT) tag system, which is operational at Columbia and Snake River dams. Because the technology underlying the POST array works in both freshwater and the ocean, it is therefore possible to extend the measurement of survival to large rivers lacking dams, such as the Fraser, and to also extend the measurement of survival to the lower Columbia River and estuary, where there are no dams. Of particular note, survival during the downstream migration of at least some endangered Columbia and Snake River Chinook and steelhead stocks appears to be as high or higher than that of the same species migrating out of the Fraser River in Canada, which lacks dams. Equally surprising, smolt survival during migration through the hydrosystem, when scaled by either the time or distance migrated, is higher than in the lower Columbia River and estuary where dams are absent. Our results raise important questions regarding the factors that are preventing the recovery of salmon stocks in the Columbia and the future health of stocks in the Fraser River. Miniature electronic technologies now allow researchers to track a salmon's migration from its birthplace in a river's headwaters in the Rocky Mountains to the North Pacific, opening a window on the mysteries of migration and survival. Surprisingly, outward migrating salmon (smolts) have similar survival during migration down dammed and undammed rivers, challenging widely held notions about factors affecting salmon abundance. Elements of the large-scale POST (Pacific Ocean Shelf Tracking) acoustic telemetry array revealed the migrations. Although salmon smolt survival to the Pacific Ocean was comparable in both the dammed Columbia and undammed Fraser rivers, it was higher in the Columbia once distance or travel time was taken into account—and higher within the hydropower system than below the dammed section. There is not yet enough evidence to determine whether (1) the Fraser has a problem that reduces salmon survival to that of a heavily dammed river or (2) factors other than dams play a larger, unsuspected role in salmon survival. Wherever future research leads on those questions, the new fish tagging technology has demonstrated itself as a useful tool for obtaining objective scientific data with important value in a number of public policy arenas. Electronic tagging of two species of salmon smolts reveals similar survival rates during migration down the dammed Columbia and undammed Fraser Rivers, challenging popular notions about factors affecting salmon abundance.
Collapse
|
2108
|
Kwiatkowska EJ, Franz BA, Meister G, McClain CR, Xiong X. Cross calibration of ocean-color bands from moderate resolution imaging spectroradiometer on Terra platform. APPLIED OPTICS 2008; 47:6796-6810. [PMID: 19104531 DOI: 10.1364/ao.47.006796] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Ocean-color applications require maximum uncertainties in blue-wavelength water-leaving radiances in oligotrophic ocean of approximately 5%. Water-leaving radiances from Moderate Resolution Imaging Spectroradiometer (MODIS) on the Terra satellite, however, exhibit temporal drift of the order of 15% as well as sensor changes in response versus scan and polarization sensitivity, which cannot be tracked by onboard calibrators. This paper introduces an instrument characterization approach that uses Earth-view data as a calibration source. The approach models the top of the atmosphere signal over ocean that the instrument is expected to measure, including its polarization, with water-leaving radiances coming from another well-calibrated global sensor. The cross calibration allows for significant improvement in derived MODIS-Terra ocean-color products, with largest changes in the blue wavelengths.
Collapse
|
2109
|
Ljung K, Torin A, Smirk M, Maley F, Cook A, Weinstein P. Extracting dust from soil: a simple solution to a tricky task. THE SCIENCE OF THE TOTAL ENVIRONMENT 2008; 407:589-593. [PMID: 18845318 DOI: 10.1016/j.scitotenv.2008.09.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2008] [Revised: 08/07/2008] [Accepted: 09/06/2008] [Indexed: 05/26/2023]
Abstract
Air quality is commonly assessed by the ambient concentration of airborne particles sized smaller than 10 microm (PM10). However, in addition to concentration, particle shape as well as the type and bioaccessibility of elements adsorbed to this particulate fraction are likely to be related to subsequent respiratory health effects. In order to investigate this relationship, a relatively large mass of the relevant size fraction is needed since sample preparation is necessary prior to analysis. Most existing methods for sampling dust have been developed for analysing the dust directly, without prior handling or digestion. In order to provide sufficient material to be used for subsequent bioaccessibility analysis, these methods require repetitive and time consuming sampling as well as special equipment and procedures which are high in both cost and maintenance. This paper describes an inexpensive and relatively simple procedure for extracting the PM10 fraction from soil to be used for lung bioaccessibility studies. The method described involves dry and wet sieving in order to exclude larger size fractions as far as possible. Vacuum filtering of the wet-sieved soil solution through a 10 microm mesh was then employed to extract the required fraction. In order to avoid frequent blocking of the mesh, Stokes's law was applied in the construction of a tube which enables separation of the solution holding the smallest fraction.
Collapse
|
2110
|
Magiera T, Kapicka A, Petrovský E, Strzyszcz Z, Fialová H, Rachwał M. Magnetic anomalies of forest soils in the Upper Silesia-Northern Moravia region. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2008; 156:618-27. [PMID: 18687508 DOI: 10.1016/j.envpol.2008.06.030] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2008] [Revised: 06/09/2008] [Accepted: 06/11/2008] [Indexed: 05/16/2023]
Abstract
Previous investigations revealed a strong magnetic anomaly due to soil magnetic enhancement in the industrialized cross-border area of Upper Silesia (Poland) and Northern Moravia (Czech Republic). Since industrial and urban dusts contain magnetic particles, this soil magnetic enhancement is assumed to be of anthropogenic origin, caused by a high concentration of atmospherically deposited magnetic particles, accumulated in topsoil layers. This assumption is proved by investigations of vertical profiles of magnetic susceptibility along a transect crossing the border area of the two countries. The results show that the population of magnetic minerals in the organic horizon is different from that in the mineral horizons. The vertical distribution of magnetic susceptibility and thermomagnetic analysis suggests negligible lithogenic contribution. The observed relationship between magnetic susceptibility and some heavy metals, confirmed by micromorphological observations and microchemical analysis of magnetic particles separated from the organic horizons of forest topsoil, has proved the usefulness of soil magnetometry for pollution study.
Collapse
|
2111
|
Springman KR, Short JW, Lindeberg MR, Maselko JM, Khan C, Hodson PV, Rice SD. Semipermeable membrane devices link site-specific contaminants to effects: Part 1 - Induction of CYP1A in rainbow trout from contaminants in Prince William Sound, Alaska. MARINE ENVIRONMENTAL RESEARCH 2008; 66:477-486. [PMID: 18845333 DOI: 10.1016/j.marenvres.2008.07.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2008] [Revised: 06/26/2008] [Accepted: 07/01/2008] [Indexed: 05/26/2023]
Abstract
Extracts from semi-permeable membrane devices (SPMDs) deployed on beaches in Prince William Sound (PWS), Alaska, were used to evaluate if complex contaminant mixtures from different sources can be distinguished by the resulting cytochrome P450 1A (CYP1A) activity in exposed test animals. Deployment sites included canneries, salmon hatcheries, and beaches where lingering oil remains from discharges during the 1964 earthquake or the 1989 Exxon Valdez oil spill. Other sites were selected at random to evaluate region-wide contaminant inputs or were located in salmon streams to evaluate contaminants carried and released by migrating salmon carcasses following reproduction. Following standard deployments of approximately 28 d, an aliquot of the accumulated contaminants was intraperitoneally injected without cleanup into juvenile rainbow trout (Oncorhynchus mykiss). After 2 d and 7 d, the activity of CYP1A was measured by the ethoxyresorufin-o-deethylase (EROD) assay. Exposure to extracts from the oiled sites and one hatchery site with numerous creosote pilings elicited strong EROD responses, whereas fish exposed to salmon stream extracts elicited weak but significant responses during late summer compared to late spring. Responses from the other sites were not significant, indicating contaminants from these sources are unlikely to cause CYP1A induction in resident biota. Rather than simply assessing extant contaminants, this method evaluates the potency of the different sites for bringing about aryl hydrocarbon receptor responses in resident biota.
Collapse
|
2112
|
Korgaonkar NS, Kumar A, Yadav RS, Kabadi D, Dash AP. Sampling of adult mosquito vectors with Mosquito Magnet Pro in Panaji, Goa, India. JOURNAL OF THE AMERICAN MOSQUITO CONTROL ASSOCIATION 2008; 24:604-607. [PMID: 19181075 DOI: 10.2987/5756.1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
For mosquito vector population monitoring, a new commercial trap, Mosquito Magnet Pro (MM-PRO), was tested for its usefulness in Goa, India. Anopheles stephensi was tested for the presence of Plasmodium sporozoite infection in the salivary glands. Using the MM-PRO 24 h a day for 34 days, 2,329 mosquitoes belonging to 16 species were collected. These included 6 species each of the genera Anopheles and Culex, 2 species of Aedes, and 1 each of Mansonia and Armigeres. Most (91%) of the mosquitoes caught were females. Among these the number and percentage of each species were Anopheles stephensi 59 (2.78%), Culex quinquefasciatus 1013 (47.78%), Culex vishnui 551 (26.0%), Mansonia uniformis 216 (10.19%), and Aedes albopictus 1 (0.04%). Of the 54 An. stephensi females tested for the presence of circumsporozoite protein (CSP) by an ELISA technique, 1 was found to be Plasmodium falciparum CSP positive. The MM-PRO device was found useful for mosquito population sampling in the urban setting of Goa.
Collapse
|
2113
|
Saldanha R, Manno M, Saleh M, Ewaze JO, Scott JA. The influence of sampling duration on recovery of culturable fungi using the Andersen N6 and RCS bioaerosol samplers. INDOOR AIR 2008; 18:464-72. [PMID: 18761682 DOI: 10.1111/j.1600-0668.2008.00547.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
UNLABELLED The influence of sampling duration on recovery of culturable fungi was compared using the Andersen N6 and the Reuter Centrifugal Sampler (RCS). Samplers were operated side-by-side, collecting 15 samples each of incrementally increasing duration (1-15 min). From 270 samples collected, 26 fungal genera were recovered. Species of Alternaria, Aspergillus, Cladosporium, Epicoccum, Penicillium and Ulocladium were most frequent. Data adjusted to CFU/m3 were fitted to a Poisson regression model with a logarithmic link function and evaluated for the impact of sampling time on qualitative and quantitative recovery of fungi, both as individual taxa and in aggregate according to xerotolerance. Significant differences between the two samplers were observed for xerotolerant and normotolerant moulds, as well as Aspergillus spp. and Cladosporium spp. With the exception of Cladosporium spp., overall recoveries were higher with the RCS. When the Andersen N6 was used, the recovered levels of Cladosporium spp. and unidentified yeasts were reduced significantly at sampling times over 6 min. Similarly, when the RCS was used, recovery of Aspergillus spp., Penicillium spp., Ulocladium spp., unidentified yeasts, and low water activity fungi declined significantly at sampling times over 6 min. PRACTICAL IMPLICATIONS Currently, the industry-wide trend for viable air sampling in indoor environmental investigations is to use sampling times between 2 and 4 min in duration. Our results support the routine use of a 6-min sampling time where low spore loads are expected, resulting in improved limits of detection.
Collapse
|
2114
|
Booth DT, Cox SE, Meikle T, Zuuring HR. Ground-cover measurements: assessing correlation among aerial and ground-based methods. ENVIRONMENTAL MANAGEMENT 2008; 42:1091-1100. [PMID: 18446407 DOI: 10.1007/s00267-008-9110-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2007] [Accepted: 12/14/2007] [Indexed: 05/26/2023]
Abstract
Wyoming's Green Mountain Common Allotment is public land providing livestock forage, wildlife habitat, and unfenced solitude, amid other ecological services. It is also the center of ongoing debate over USDI Bureau of Land Management's (BLM) adjudication of land uses. Monitoring resource use is a BLM responsibility, but conventional monitoring is inadequate for the vast areas encompassed in this and other public-land units. New monitoring methods are needed that will reduce monitoring costs. An understanding of data-set relationships among old and new methods is also needed. This study compared two conventional methods with two remote sensing methods using images captured from two meters and 100 meters above ground level from a camera stand (a ground, image-based method) and a light airplane (an aerial, image-based method). Image analysis used SamplePoint or VegMeasure software. Aerial methods allowed for increased sampling intensity at low cost relative to the time and travel required by ground methods. Costs to acquire the aerial imagery and measure ground cover on 162 aerial samples representing 9000 ha were less than $3000. The four highest correlations among data sets for bare ground--the ground-cover characteristic yielding the highest correlations (r)--ranged from 0.76 to 0.85 and included ground with ground, ground with aerial, and aerial with aerial data-set associations. We conclude that our aerial surveys are a cost-effective monitoring method, that ground with aerial data-set correlations can be equal to, or greater than those among ground-based data sets, and that bare ground should continue to be investigated and tested for use as a key indicator of rangeland health.
Collapse
|
2115
|
Liu S, Tao S, Liu W, Dou H, Liu Y, Zhao J, Little MG, Tian Z, Wang J, Wang L, Gao Y. Seasonal and spatial occurrence and distribution of atmospheric polycyclic aromatic hydrocarbons (PAHs) in rural and urban areas of the North Chinese Plain. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2008; 156:651-656. [PMID: 18674851 DOI: 10.1016/j.envpol.2008.06.029] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2008] [Revised: 06/07/2008] [Accepted: 06/11/2008] [Indexed: 05/26/2023]
Abstract
Passive air sampling (PAS) was employed to study the occurrence of gaseous and particle-bound PAHs in the North Chinese Plain. The averaged concentrations of gaseous and particle-bound PAHs were 485+/-209 ng/m(3) and 267+/-161 ng/m(3), respectively. The PAHs concentrations at urban sites were generally higher than those at rural ones with ratios <1.5 in spring, summer and fall, but differences between them were not significant for the wintertime and annually averaged concentrations. This urban-rural distribution pattern was related to the PAHs emission sources. PAHs spatial variation can be partially (49%) explained by emission with a simple linear regression method. Both the gaseous and particle-bound PAHs were highest in winter and lowest in summer, with winter/summer ratios of 1.8 and 8, respectively. Emission strength was the most important factor for the seasonality.
Collapse
|
2116
|
Bozlaker A, Odabasi M, Muezzinoglu A. Dry deposition and soil-air gas exchange of polychlorinated biphenyls (PCBs) in an industrial area. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2008; 156:784-793. [PMID: 18640753 DOI: 10.1016/j.envpol.2008.06.008] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2008] [Revised: 05/30/2008] [Accepted: 06/01/2008] [Indexed: 05/26/2023]
Abstract
Ambient air and dry deposition, and soil samples were collected at the Aliaga industrial site in Izmir, Turkey. Atmospheric total (particle+gas) Sigma(41)-PCB concentrations were higher in summer (3370+/-1617 pg m(-3), average+SD) than in winter (1164+/-618 pg m(-3)), probably due to increased volatilization with temperature. Average particulate Sigma(41)-PCBs dry deposition fluxes were 349+/-183 and 469+/-328 ng m(-2) day(-1) in summer and winter, respectively. Overall average particulate deposition velocity was 5.5+/-3.5 cm s(-1). The spatial distribution of Sigma(41)-PCB soil concentrations (n=48) showed that the iron-steel plants, ship dismantling facilities, refinery and petrochemicals complex are the major sources in the area. Calculated air-soil exchange fluxes indicated that the contaminated soil is a secondary source to the atmosphere for lighter PCBs and as a sink for heavier ones. Comparable magnitude of gas exchange and dry particle deposition fluxes indicated that both mechanisms are equally important for PCB movement between air and soil in Aliaga.
Collapse
|
2117
|
Chaemfa C, Barber JL, Gocht T, Harner T, Holoubek I, Klanova J, Jones KC. Field calibration of polyurethane foam (PUF) disk passive air samplers for PCBs and OC pesticides. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2008; 156:1290-1297. [PMID: 18474408 DOI: 10.1016/j.envpol.2008.03.016] [Citation(s) in RCA: 74] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2007] [Revised: 03/05/2008] [Accepted: 03/20/2008] [Indexed: 05/26/2023]
Abstract
Different passive air sampler (PAS) strategies have been developed for sampling in remote areas and for cost-effective simultaneous spatial mapping of POPs (persistent organic pollutants) over differing geographical scales. The polyurethane foam (PUF) disk-based PAS is probably the most widely used. In a PUF-based PAS, the PUF disk is generally mounted inside two stainless steel bowls to buffer the air flow to the disk and to shield it from precipitation and light. The field study described in this manuscript was conducted to: compare performance of 3 different designs of sampler; to further calibrate the sampler against the conventional active sampler; to derive more information on field-based uptake rates and equilibrium times of the samplers. Samplers were also deployed at different locations across the field site, and at different heights up a meteorological tower, to investigate the possible influence of sampler location. Samplers deployed <5m above ground, and not directly sheltered from the wind gave similar uptake rates. Small differences in dimensions between the 3 designs of passive sampler chamber had no discernable effect on accumulation rates, allowing comparison with previously published data.
Collapse
|
2118
|
Li YY, Jiang ZY, Chen JQ, Li HL, Zhang HQ. Environment-friendly determination of low concentration azobenzene beta-cyclodextrin-modified electrode. BIOMEDICAL AND ENVIRONMENTAL SCIENCES : BES 2008; 21:479-484. [PMID: 19263803 DOI: 10.1016/s0895-3988(09)60006-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
OBJECTIVE To study environment-friendly determination of azobenzene in trace amounts using beta-cyclodextrin (beta-CD)-modified Au electrode. METHODS beta-CD-modified Au electrode was fabricated with a two-step approach, and then a gold electrode modified with beta-CD was used to detect azobenzene by employing Osteryoung square wave voltammetry. RESULTS The modified electrode could detect azobenzene, showing a good linearity between the electrochemical current and concentration. CONCLUSION Although the electrochemical current is related with concentration, the detection limit is around 1.0 x 10(-10) mol/L. This study may provide a new environment-friendly approach for monitoring water quality.
Collapse
|
2119
|
Shim BS, Chen W, Doty C, Xu C, Kotov NA. Smart electronic yarns and wearable fabrics for human biomonitoring made by carbon nanotube coating with polyelectrolytes. NANO LETTERS 2008; 8:4151-7. [PMID: 19367926 DOI: 10.1021/nl801495p] [Citation(s) in RCA: 126] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
The idea of electronic yarns and textiles has appeared for quite some time, but their properties often do not meet practical expectations. In addition to chemicallmechanical durability and high electrical conductivity, important materials qualifications include weavablity, wearability, light weight, and "smart" functionalities. Here we demonstrate a simple process of transforming general commodity cotton threads into intelligent e-textiles using a polyelectrolyte-based coating with carbon nanotubes (CNTs). Efficient charge transport through the network of nanotubes (20 omega/cm) and the possibility to engineer tunneling junctions make them promising materials for many high-knowledge-content garments. Along with integrated humidity sensing, we demonstrate that CNT-cotton threads can be used to detect albumin, the key protein of blood, with high sensitivity and selectivity. Notwithstanding future challenges, these proof-of-concept demonstrations provide a direct pathway for the application of these materials as wearable biomonitoring and telemedicine sensors, which are simple, sensitive, selective, and versatile.
Collapse
|
2120
|
Wen X, Fei J, Chen X, Yi L, Ge F, Huang M. Electrochemical analysis of trifluralin using a nanostructuring electrode with multi-walled carbon nanotubes. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2008; 156:1015-1020. [PMID: 18539374 DOI: 10.1016/j.envpol.2008.05.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2008] [Revised: 04/30/2008] [Accepted: 05/03/2008] [Indexed: 05/26/2023]
Abstract
The electroanalytical behaviors of the endocrine-disrupting chemical trifluralin have been studied at a nanostructuring electrode. The nanostructuring electrode was fabricated by coating a uniform multi-wall carbon nanotubes/dihexadecyl hydrogen phosphate (MWNTs/DHP) film on glassy carbon electrode (GCE). The reduction peak currents of trifluralin increased remarkably and the reduction peak potential shifted positively at the nanostructuring electrode, compared with that at a bare GCE. The results showed that this nanostructuring electrode exhibited excellent enhancement effects on the electrochemical reduction of trifluralin. Consequently, a simple and sensitive electroanalytical method was developed for the determination of trifluralin. Under optimal conditions, a linear response of trifluralin was obtained in the range from 5.0 x 10(-9) to 6.0 x 10(-6) mol L(-1) (r=0.998) and with a limit of detect (LOD) of 2.0 x 10(-9) mol L(-1). The proposed procedure was successfully applied to determine trifluralin in soil samples with satisfactory results.
Collapse
|
2121
|
Sun ZH, Cao WX, Zhao J, Li C, Zhou W. [Construction and test of long pathlength automated analyzer of trace nutrients in seawater]. GUANG PU XUE YU GUANG PU FEN XI = GUANG PU 2008; 28:3000-3003. [PMID: 19248532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Nutrients are routine aspects for marine environment monitoring. With low concentration in oceans, nutrients are difficult to be measured with a routine spectrophotometer. Based on liquid core waveguides, a new high-sensitivity analyzer was constructed to measure trace nutrients in oceans. The analyzer can provide continuous measurement of spectral absorbance of water sample in the spectral range from 350 to 900 nm with a spectral resolution of 1.02 nm. The processes such as sample injection, data acquisition of absorbance and data analysis are automatically controlled by a built-in PC104 micro computer. The results of test proved that, with the reaction time of about three minutes, the analyzer could provide a detection limit of the order of nmol x L(-1), which is about 1 000 times lower than that of routine spectrophotometer. The analyzer is amenable to trace nutrients monitoring in oceans.
Collapse
|
2122
|
Short JW, Springman KR, Lindeberg MR, Holland LG, Larsen ML, Sloan CA, Khan C, Hodson PV, Rice SD. Semipermeable membrane devices link site-specific contaminants to effects: PART II - A comparison of lingering Exxon Valdez oil with other potential sources of CYP1A inducers in Prince William Sound, Alaska. MARINE ENVIRONMENTAL RESEARCH 2008; 66:487-498. [PMID: 18845332 DOI: 10.1016/j.marenvres.2008.08.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2008] [Revised: 08/18/2008] [Accepted: 08/19/2008] [Indexed: 05/26/2023]
Abstract
We deployed semipermeable membrane devices (SPMDs) on beaches for 28 days at 53 sites in Prince William Sound (PWS), Alaska, to evaluate the induction potential from suspected sources of cytochrome P450 1A (CYP1A)-inducing contaminants. Sites were selected to assess known point sources, or were chosen randomly to evaluate the region-wide sources. After deployment, SPMD extracts were analyzed chemically for persistent organic pollutants (POPs) and polycyclic aromatic hydrocarbons (PAH). These results were compared with hepatic CYP1A enzyme activity of juvenile rainbow trout injected with the same extracts prior to clean-up for the chemical analyses. Increased CYP1A activity was strongly associated with PAH concentrations in extracts, especially chrysene homologues but was not associated with POPs. The only apparent sources of chrysene homologues were lingering oil from Exxon Valdez, asphalt and bunker fuels released from storage tanks during the 1964 Alaska earthquake, creosote leaching from numerous pilings at one site, and PAH-contaminated sediments at Cordova Harbor. Our results indicate that PWS is remarkably free of pollution from PAH when nearby sources are absent as well as from pesticides and PCBs generally.
Collapse
|
2123
|
Donovan C, Dewan A, Heo D, Beyenal H. Batteryless, wireless sensor powered by a sediment microbial fuel cell. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2008; 42:8591-6. [PMID: 19068853 DOI: 10.1021/es801763g] [Citation(s) in RCA: 73] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Sediment microbial fuel cells (SMFCs) are considered to be an alternative renewable power source for remote monitoring. There are two main challenges to using SMFCs as power sources: 1) a SMFC produces a low potential at which most sensor electronics do not operate, and 2) a SMFC cannot provide continuous power, so energy from the SMFC must be stored and then used to repower sensor electronics intermittently. In this study, we developed a SMFC and a power management system (PMS) to power a batteryless, wireless sensor. A SMFC operating with a microbial anode and cathode, located in the Palouse River, Pullman, Washington, U.S.A., was used to demonstrate the utility of the developed system. The designed PMS stored microbial energy and then started powering the wireless sensor when the SMFC potential reached 320 mV. It continued powering until the SMFC potential dropped below 52 mV. The system was repowered when the SMFC potential increased to 320 mV, and this repowering continued as long as microbial reactions continued. We demonstrated that a microbial fuel cell with a microbial anode and cathode can be used as an effective renewable power source for remote monitoring using custom-designed electronics.
Collapse
|
2124
|
Arditsoglou A, Voutsa D. Passive sampling of selected endocrine disrupting compounds using polar organic chemical integrative samplers. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2008; 156:316-324. [PMID: 18359135 DOI: 10.1016/j.envpol.2008.02.007] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2007] [Revised: 02/08/2008] [Accepted: 02/12/2008] [Indexed: 05/26/2023]
Abstract
Two types of polar organic chemical integrative samplers (pharmaceutical POCIS and pesticide POCIS) were examined for their sampling efficiency of selected endocrine disrupting compounds (EDCs). Laboratory-based calibration of POCISs was conducted by exposing them at high and low concentrations of 14 EDCs (4-alkyl-phenols, their ethoxylate oligomers, bisphenol A, selected estrogens and synthetic steroids) for different time periods. The kinetic studies showed an integrative uptake up to 28days. The sampling rates for the individual compounds were obtained. The use of POCISs could result in an integrative approach to the quality status of the aquatic systems especially in the case of high variation of water concentrations of EDCs. The sampling efficiency of POCISs under various field conditions was assessed after their deployment in different aquatic environments.
Collapse
|
2125
|
Munson CA, Gottfried JL, Snyder EG, De Lucia FC, Gullett B, Miziolek AW. Detection of indoor biological hazards using the man-portable laser induced breakdown spectrometer. APPLIED OPTICS 2008; 47:G48-G57. [PMID: 19122702 DOI: 10.1364/ao.47.000g48] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
The performance of a man-portable laser induced breakdown spectrometer was evaluated for the detection of biological powders on indoor office surfaces and wipe materials. Identification of pure unknown powders was performed by comparing against a library of spectra containing biological agent surrogates and confusant materials, such as dusts, diesel soot, natural and artificial sweeteners, and drink powders, using linear correlation analysis. Simple models constructed using a second technique, partial least squares discriminant analysis, successfully identified Bacillus subtilis (BG) spores on wipe materials and office surfaces. Furthermore, these models were able to identify BG on materials not used in the training of the model.
Collapse
|