1
|
Janko M, Santaniello SD, Brockmann C, Wolf M, Grauhan NF, Schöffling VI, Dimova V, Ponto K, Hoffmann EM, Kleinekofort W, Othman AE, Brockmann MA, Kronfeld A. Comparison of T1-weighted landmark placement and ROI transfer onto diffusion-weighted EPI sequences for targeted tractography tasks in the optic nerve. Eur J Neurosci 2024; 60:4987-4999. [PMID: 39085986 DOI: 10.1111/ejn.16490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 07/11/2024] [Accepted: 07/20/2024] [Indexed: 08/02/2024]
Abstract
Diffusion-based tractography in the optic nerve requires sampling strategies assisted by anatomical landmark information (regions of interest [ROIs]). We aimed to investigate the feasibility of expert-placed, high-resolution T1-weighted ROI-data transfer onto lower spatial resolution diffusion-weighted images. Slab volumes from 20 volunteers were acquired and preprocessed including distortion bias correction and artifact reduction. Constrained spherical deconvolution was used to generate a directional diffusion information grid (fibre orientation distribution-model [FOD]). Three neuroradiologists marked landmarks on both diffusion imaging variants and structural datasets. Structural ROI information (volumetric interpolated breath-hold sequence [VIBE]) was respectively registered (linear with 6/12 degrees of freedom [DOF]) onto single-shot EPI (ss-EPI) and readout-segmented EPI (rs-EPI) volumes, respectively. All eight ROI/FOD-combinations were compared in a targeted tractography task of the optic nerve pathway. Inter-rater reliability for placed ROIs among experts was highest in VIBE images (lower confidence interval 0.84 to 0.97, mean 0.91) and lower in both ss-EPI (0.61 to 0.95, mean 0.79) and rs-EPI (0.59 to 0.86, mean 0.70). Tractography success rate based on streamline selection performance was highest in VIBE-drawn ROIs registered (6-DOF) onto rs-EPI FOD (70.0% over 5%-threshold, capped to failed ratio 39/16) followed by both 12-DOF-registered (67.5%; 41/16) and nonregistered VIBE (67.5%; 40/23). On ss-EPI FOD, VIBE-ROI-datasets obtained fewer streamlines overall with each at 55.0% above 5%-threshold and with lower capped to failed ratio (6-DOF: 35/36; 12-DOF: 34/34, nonregistered 33/36). The combination of VIBE-placed ROIs (highest inter-rater reliability) with 6-DOF registration onto rs-EPI targets (best streamline selection performance) is most suitable for white matter template generation required in group studies.
Collapse
Affiliation(s)
- Markus Janko
- Department of Neuroradiology, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Sascha D Santaniello
- Department of Neuroradiology, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Carolin Brockmann
- Department of Neuroradiology, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Marcel Wolf
- Department of Neuroradiology, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Nils F Grauhan
- Department of Neuroradiology, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Vanessa I Schöffling
- Department of Neuroradiology, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Violeta Dimova
- Department of Neurology, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Katharina Ponto
- Department of Ophthalmology, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Esther M Hoffmann
- Department of Ophthalmology, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| | | | - Ahmed E Othman
- Department of Neuroradiology, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Marc A Brockmann
- Department of Neuroradiology, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Andrea Kronfeld
- Department of Neuroradiology, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| |
Collapse
|
2
|
Kashiwagi N, Sakai M, Nakamoto A, Takahashi H, Isogawa Y, Suzuki Y, Yamada S, Tomiyama M, Nakanishi K, Tomiyama N. Reverse Encoding Distortion Correction for Clinical Head Echo-Planar Diffusion-Weighted MRI: Initial Experience. J Comput Assist Tomogr 2024:00004728-990000000-00353. [PMID: 39190721 DOI: 10.1097/rct.0000000000001658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/29/2024]
Abstract
OBJECTIVE This study aimed to evaluate the feasibility of the recently commercialized reverse encoding distortion correction (RDC) method for echo-planar imaging (EPI) diffusion-weighted imaging (DWI) by applying clinical head MRI. METHODS This study included 50 consecutive patients who underwent head MRI, including single-shot (SS) EPI DWI and RDC-EPI DWI. For evaluation of normal structures, qualitative scores for image distortion, Dice similarity coefficient (DSC) values, distortion ratios, and mean apparent diffusion coefficient (ADC) values were assessed in the pons, temporal lobe at the skull base, and frontal lobe at the level of the lateral ventricles in 30 patients. To evaluate pathologies, qualitative scores for image distortion were assessed for 25 intracranial and 21 extracranial pathologies identified in 32 patients. RESULTS Qualitative scores for image distortion, DSC values, distortion ratios, and mean ADC values of the pons and temporal lobe were significantly different between SS-EPI DWI and RDC-EPI DWI, whereas those of the frontal lobe at the level of the lateral ventricles were not significantly different between the 2 DWIs. The qualitative scores for image distortion and mean ADC values of extracranial pathologies were significantly different between the DWIs, whereas those of intracranial pathologies were not significantly different. CONCLUSIONS RDC-EPI DWI significantly reduced image distortion and showed higher mean ADC values of the brain parenchyma in the skull base and extracranial pathologies.
Collapse
Affiliation(s)
- Nobuo Kashiwagi
- From the Department of Diagnostic and Interventional Radiology, Osaka International Cancer Institute
| | - Mio Sakai
- From the Department of Diagnostic and Interventional Radiology, Osaka International Cancer Institute
| | | | | | | | - Yuki Suzuki
- Department of Artificial Intelligence Diagnostic Radiology, Osaka University Graduate School of Medicine
| | - Sawaka Yamada
- Department of Radiology, Diagnostic and Interventional Radiology, Osaka International Cancer Institute, Osaka, Japan
| | - Miyuki Tomiyama
- Department of Radiology, Diagnostic and Interventional Radiology, Osaka International Cancer Institute, Osaka, Japan
| | - Katsuyuki Nakanishi
- Department of Radiology, Diagnostic and Interventional Radiology, Osaka International Cancer Institute, Osaka, Japan
| | | |
Collapse
|
3
|
Zhang Z, Aygun E, Shih SF, Raman SS, Sung K, Wu HH. High-resolution prostate diffusion MRI using eddy current-nulled convex optimized diffusion encoding and random matrix theory-based denoising. MAGMA (NEW YORK, N.Y.) 2024; 37:603-619. [PMID: 38349453 PMCID: PMC11323217 DOI: 10.1007/s10334-024-01147-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 12/12/2023] [Accepted: 01/04/2024] [Indexed: 02/17/2024]
Abstract
OBJECTIVE To develop and evaluate a technique combining eddy current-nulled convex optimized diffusion encoding (ENCODE) with random matrix theory (RMT)-based denoising to accelerate and improve the apparent signal-to-noise ratio (aSNR) and apparent diffusion coefficient (ADC) mapping in high-resolution prostate diffusion-weighted MRI (DWI). MATERIALS AND METHODS: Eleven subjects with clinical suspicion of prostate cancer were scanned at 3T with high-resolution (HR) (in-plane: 1.0 × 1.0 mm2) ENCODE and standard-resolution (1.6 × 2.2 mm2) bipolar DWI sequences (both had 7 repetitions for averaging, acquisition time [TA] of 5 min 50 s). HR-ENCODE was retrospectively analyzed using three repetitions (accelerated effective TA of 2 min 30 s). The RMT-based denoising pipeline utilized complex DWI signals and Marchenko-Pastur distribution-based principal component analysis to remove additive Gaussian noise in images from multiple coils, b-values, diffusion encoding directions, and repetitions. HR-ENCODE with RMT-based denoising (HR-ENCODE-RMT) was compared with HR-ENCODE in terms of aSNR in prostate peripheral zone (PZ) and transition zone (TZ). Precision and accuracy of ADC were evaluated by the coefficient of variation (CoV) between repeated measurements and mean difference (MD) compared to the bipolar ADC reference, respectively. Differences were compared using two-sided Wilcoxon signed-rank tests (P < 0.05 considered significant). RESULTS HR-ENCODE-RMT yielded 62% and 56% higher median aSNR than HR-ENCODE (b = 800 s/mm2) in PZ and TZ, respectively (P < 0.001). HR-ENCODE-RMT achieved 63% and 70% lower ADC-CoV than HR-ENCODE in PZ and TZ, respectively (P < 0.001). HR-ENCODE-RMT ADC and bipolar ADC had low MD of 22.7 × 10-6 mm2/s in PZ and low MD of 90.5 × 10-6 mm2/s in TZ. CONCLUSIONS HR-ENCODE-RMT can shorten the acquisition time and improve the aSNR of high-resolution prostate DWI and achieve accurate and precise ADC measurements in the prostate.
Collapse
Affiliation(s)
- Zhaohuan Zhang
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Elif Aygun
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Shu-Fu Shih
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Steven S Raman
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
| | - Kyunghyun Sung
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Holden H Wu
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA.
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA.
| |
Collapse
|
4
|
McTavish S, Van AT, Peeters JM, Weiss K, Harder FN, Makowski MR, Braren RF, Karampinos DC. Partial Fourier in the presence of respiratory motion in prostate diffusion-weighted echo planar imaging. MAGMA (NEW YORK, N.Y.) 2024; 37:621-636. [PMID: 38743376 PMCID: PMC11417066 DOI: 10.1007/s10334-024-01162-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 03/05/2024] [Accepted: 04/24/2024] [Indexed: 05/16/2024]
Abstract
PURPOSE To investigate the effect of respiratory motion in terms of signal loss in prostate diffusion-weighted imaging (DWI), and to evaluate the usage of partial Fourier in a free-breathing protocol in a clinically relevant b-value range using both single-shot and multi-shot acquisitions. METHODS A controlled breathing DWI acquisition was first employed at 3 T to measure signal loss from deep breathing patterns. Single-shot and multi-shot (2-shot) acquisitions without partial Fourier (no pF) and with partial Fourier (pF) factors of 0.75 and 0.65 were employed in a free-breathing protocol. The apparent SNR and ADC values were evaluated in 10 healthy subjects to measure if low pF factors caused low apparent SNR or overestimated ADC. RESULTS Controlled breathing experiments showed a difference in signal coefficient of variation between shallow and deep breathing. In free-breathing single-shot acquisitions, the pF 0.65 scan showed a significantly (p < 0.05) higher apparent SNR than pF 0.75 and no pF in the peripheral zone (PZ) of the prostate. In the multi-shot acquisitions in the PZ, pF 0.75 had a significantly higher apparent SNR than 0.65 pF and no pF. The single-shot pF 0.65 scan had a significantly lower ADC than single-shot no pF. CONCLUSION Deep breathing patterns can cause intravoxel dephasing in prostate DWI. For single-shot acquisitions at a b-value of 800 s/mm2, any potential risks of motion-related artefacts at low pF factors (pF 0.65) were outweighed by the increase in signal from a lower TE, as shown by the increase in apparent SNR. In multi-shot acquisitions however, the minimum pF factor should be larger, as shown by the lower apparent SNR at low pF factors.
Collapse
Affiliation(s)
- Sean McTavish
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.
| | - Anh T Van
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | | | | | - Felix N Harder
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Marcus R Makowski
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Rickmer F Braren
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Dimitrios C Karampinos
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| |
Collapse
|
5
|
Tang X, Gao J, Aburas A, Wu D, Chen Z, Chen H, Hu C. Accelerated multi-b-value multi-shot diffusion-weighted imaging based on EPI with keyhole and a low-rank tensor constraint. Magn Reson Imaging 2024; 110:138-148. [PMID: 38641211 DOI: 10.1016/j.mri.2024.04.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 04/08/2024] [Accepted: 04/10/2024] [Indexed: 04/21/2024]
Abstract
PURPOSE Multi-Shot (MS) Echo-Planar Imaging (EPI) may improve the in-plane resolution of multi-b-value DWI, yet it also considerably increases the scan time. Here we explored the combination of EPI with Keyhole (EPIK) and a calibrationless reconstruction algorithm for acceleration of multi-b-value MS-DWI. METHODS We firstly analyzed the impact of nonuniform phase accrual in EPIK on the reconstructed image. Based on insights gained from the analysis, we developed a calibrationless reconstruction algorithm based on a Space-Contrast-Coil Locally Low-Rank Tensor (SCC-LLRT) constraint for reconstruction of EPIK-acquired data. We compared the algorithm with a modified SPatial-Angular Locally Low-Rank (SPA-LLR) algorithm through simulations, phantoms, and in vivo study. We then compared EPIK with uniformly undersampled EPI for accelerating multi-b-value DWI in 6 healthy subjects. RESULTS Through theoretical derivations, we found that the reconstruction of EPIK with a SENSE-encoding-based algorithm, such as SPA-LLR, may cause additional aliasing artifacts due to the frequency-dependent distortion of the coil sensitivity. Results from simulations, phantoms, and in vivo study verified the theoretical finding by showing that the calibrationless SCC-LLRT algorithm reduced aliasing artifacts compared with SPA-LLR. Finally, EPIK with SCC-LLRT substantially reduced the ghosting artifacts compared with uniform undersampled multi-b-value DWI, decreasing the fitting errors in ADC (0.05 ± 0.01 vs 0.10 ± 0.01, P < 0.001) and IVIM mapping (0.026 ± 0.004 vs 0.06 ± 0.006, P < 0.001). CONCLUSION The SCC-LLRT algorithm reduced the aliasing artifacts of EPIK by using a calibrationless modeling of the multi-coil data. The dense sampling of k-space center offers EPIK a potential to improve image quality for acceleration of multi-b-value MS-DWI.
Collapse
Affiliation(s)
- Xin Tang
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China; United Imaging Healthcare Co. Ltd, Shanghai, China
| | - Juan Gao
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Ahmed Aburas
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Dan Wu
- Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China
| | - Zhuo Chen
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Hao Chen
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Chenxi Hu
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
6
|
Yang H, Wang G, Li Z, Li H, Zheng J, Hu Y, Cao X, Liao C, Ye H, Tian Q. Artificial intelligence for neuro MRI acquisition: a review. MAGMA (NEW YORK, N.Y.) 2024; 37:383-396. [PMID: 38922525 DOI: 10.1007/s10334-024-01182-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 06/11/2024] [Accepted: 06/14/2024] [Indexed: 06/27/2024]
Abstract
OBJECT To review recent advances of artificial intelligence (AI) in enhancing the efficiency and throughput of the MRI acquisition workflow in neuroimaging, including planning, sequence design, and correction of acquisition artifacts. MATERIALS AND METHODS A comprehensive analysis was conducted on recent AI-based methods in neuro MRI acquisition. The study focused on key technological advances, their impact on clinical practice, and potential risks associated with these methods. RESULTS The findings indicate that AI-based algorithms have a substantial positive impact on the MRI acquisition process, improving both efficiency and throughput. Specific algorithms were identified as particularly effective in optimizing acquisition steps, with reported improvements in workflow efficiency. DISCUSSION The review highlights the transformative potential of AI in neuro MRI acquisition, emphasizing the technological advances and clinical benefits. However, it also discusses potential risks and challenges, suggesting areas for future research to mitigate these concerns and further enhance AI integration in MRI acquisition.
Collapse
Affiliation(s)
- Hongjia Yang
- School of Biomedical Engineering, Tsinghua University, Beijing, China
| | - Guanhua Wang
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Ziyu Li
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Haoxiang Li
- School of Biomedical Engineering, Tsinghua University, Beijing, China
| | - Jialan Zheng
- School of Biomedical Engineering, Tsinghua University, Beijing, China
| | - Yuxin Hu
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Xiaozhi Cao
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Congyu Liao
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Huihui Ye
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, China
| | - Qiyuan Tian
- School of Biomedical Engineering, Tsinghua University, Beijing, China.
- Tsinghua Laboratory of Brain and Intelligence, Tsinghua University, Beijing, China.
| |
Collapse
|
7
|
Zha F, Feng C, Xu J, Zou Q, Li J, Hu D, Liu WV, Li Z, Wu S. Evaluation of multiplexed sensitivity encoding diffusion-weighted imaging in detecting uterine lesions: Image quality optimization. Magn Reson Imaging 2024; 110:17-22. [PMID: 38452829 DOI: 10.1016/j.mri.2024.03.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Revised: 03/03/2024] [Accepted: 03/03/2024] [Indexed: 03/09/2024]
Abstract
PURPOSE To compare the image quality of multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE-DWI) and single-shot echo-planar imaging (SS-EPI-DWI) techniques in uterine MRI. METHODS Eighty-eight eligible patients underwent MUSE-DWI and SS-EPI-DWI examinations simultaneously using a 3.0 T MRI system. Two radiologists independently performed quantitative and qualitative analysis of the two groups of images using a double-blind method. The weighted Kappa test was used to evaluate the interobserver agreement. Wilcoxon's rank sum test was used for qualitative parameters, and paired t-test was used for quantitative parameters. Spearman rank correlation analysis was used to obtained correlation between pathological results and mean apparent diffusion coefficient (ADC) value. RESULTS The qualitative and quantitative analysis of the images by the two radiologists were in good or excellent agreement, with weighted kappa value ranging from 0.636 to 0.981. The scores of total subjective image quality (15.4 ± 0.99) and signal-to-noise ratio (158.99 ± 60.71) of MUSE-DWI were significantly higher than those of SS-EPI-DWI (12.93 ± 1.62 P < 0.001; 130.23 ± 48.29 P < 0.05). It effectively reduced image distortion and artifact, and had better lesion conspicuity. There was no significant difference in contrast-to-noise ratio score and average ADC values between the two DWI sequences. The average ADC values of the two DWI sequences were highest in the normal uterus group and lowest in the endometrial cancer group, with statistically significant differences among groups (P < 0.01). In addition, the average ADC values of the two DWI sequences were negatively correlated with the type of lesions, decreasing with the malignancy of the lesions (r = -0.805 P < 0.01, r = -0.815 P < 0.01). CONCLUSION Compared to SS-EPI-DWI, MUSE-DWI can significantly reduce distortion, artifacts, and fuzziness in MRI of uterine lesions, which is more conducive to lesion detection.
Collapse
Affiliation(s)
- Fuxiang Zha
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Cui Feng
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Jin Xu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Qian Zou
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Jiali Li
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Daoyu Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | | | - Zhen Li
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China
| | - Sisi Wu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China.
| |
Collapse
|
8
|
Cheng Y, Zhang L, Wu X, Zou Y, Niu Y, Wang L. Impact of prostate MRI image quality on diagnostic performance for clinically significant prostate cancer (csPCa). Abdom Radiol (NY) 2024:10.1007/s00261-024-04458-7. [PMID: 38935093 DOI: 10.1007/s00261-024-04458-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 06/14/2024] [Accepted: 06/15/2024] [Indexed: 06/28/2024]
Abstract
OBJECTIVES With the widespread clinical application of prostate magnetic resonance imaging (MRI), there has been an increasing demand for lesion detection and accurate diagnosis in prostate MR, which relies heavily on satisfactory image quality. Focusing on the primary sequences involved in Prostate Imaging Reporting and Data System (PI-RADS), this study have evaluated common quality issues in clinical practice (such as signal-to-noise ratio (SNR), artifacts, boundaries, and enhancement). The aim of the study was to determine the impact of image quality on clinically significant prostate cancer (csPCa) detection, positive predictive value (PPV) and radiologist's diagnosis in different sequences and prostate zones. METHODS This retrospective study included 306 patients who underwent prostate MRI with definitive pathological reports from February 2021 to December 2022. All histopathological specimens were evaluated according to the recommendations of the International Society of Urological Pathology (ISUP). An ISUP Grade Group ≥ 2 was considered as csPCa. Three radiologists from different centers respectively performed a binary classification assessment of image quality in the following ten aspects: (1) T2WI in the axial plane: SNR, prostate boundary conditions, the presence of artifacts; (2) T2WI in the sagittal or coronal plane: prostate boundary conditions; (3) DWI: SNR, delineation between the peripheral and transition zone, the presence of artifacts, the matching of DWI and T2WI images; (4) DCE: the evaluation of obturator artery enhancement, the evaluation of dynamic contrast enhancement. Fleiss' Kappa was used to determine the inter-reader agreement. Wilson's 95% confidence interval (95% CI) was used to calculate PPV. Chi-square test was used to calculate statistical significance. A p-value < 0.05 was considered statistically significant. RESULTS High-quality images had a higher csPCa detection rate (56.5% to 64.3%) in axial T2WI, DWI, and DCE, with significant statistical differences in SNR in axial T2WI (p 0.002), the presence of artifacts in axial T2WI (p 0.044), the presence of artifacts in DWI (p < 0.001), and the matching of DWI and T2WI images (p < 0.001). High-quality images had a higher PPV (72.5% to 78.8%) and showed significant statistical significance in axial T2WI, DWI, and DCE. Additionally, we found that PI-RADS 3 (24.0% to 52.9%) contained more low-quality images compared to PI-RADS 4-5 (20.6% to 39.3%), with significant statistical differences in the prostate boundary conditions in axial T2WI (p 0.048) and the presence of artifacts in DWI (p 0.001). Regarding the relationship between csPCa detection and image quality in different prostate zones, this study found that significant statistical differences were only observed between high- (63.5% to 75.7%) and low-quality (30.0% to 50.0%) images in the peripheral zone (PZ). CONCLUSION Prostate MRI quality may have an impact on the diagnostic performance. The poorer image quality is associated with lower csPCa detection rates and PPV, which can lead to an increase in radiologist's ambiguous diagnosis (PI-RADS 3), especially for the lesions located at PZ.
Collapse
Affiliation(s)
- Yue Cheng
- Department of Radiology, Capital Medical University Affiliated Beijing Friendship Hospital, 36 Yong'an Rd, Xicheng District, Beijing, 100016, China
| | - Lei Zhang
- Department of Radiology, The Second People's Hospital of Baoshan, Yunnan, China
| | - Xiaohui Wu
- Department of Radiology, Hailar People's Hospital, Hulunbuir City, Inner Mongolia, China
| | - Yi Zou
- Department of Radiology, Hubei University of Science and Technology Affiliated Chibi's Hospital, Hubei, China
| | - Yao Niu
- Department of Radiology, Capital Medical University Affiliated Beijing Friendship Hospital, 36 Yong'an Rd, Xicheng District, Beijing, 100016, China
| | - Liang Wang
- Department of Radiology, Capital Medical University Affiliated Beijing Friendship Hospital, 36 Yong'an Rd, Xicheng District, Beijing, 100016, China.
| |
Collapse
|
9
|
Zöllner FG. Editorial for "Comparison of Reduced and Full Field of View in Diffusion-Weighted MRI on Image Quality: A Meta-Analysis". J Magn Reson Imaging 2024. [PMID: 38924186 DOI: 10.1002/jmri.29488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Accepted: 04/26/2024] [Indexed: 06/28/2024] Open
Affiliation(s)
- Frank G Zöllner
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
- Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| |
Collapse
|
10
|
Shi J, Lin J, Zhou X, Yin N, Wu L, Yu M, Xu M. Comparison of Reduced and Full Field of View in Diffusion-Weighted MRI on Image Quality: A Meta-Analysis. J Magn Reson Imaging 2024. [PMID: 38896049 DOI: 10.1002/jmri.29487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 06/01/2024] [Accepted: 06/03/2024] [Indexed: 06/21/2024] Open
Abstract
BACKGROUND Reduced field of view (rFOV) diffusion-weighted imaging (DWI) in MRI shows potential for enhanced image quality compared with traditional full field of view (fFOV) DWI. Evaluating rFOV DWI's impact on image quality is important for clinical adoption. OBJECTIVE To assess the efficacy of rFOV DWI in improving image quality, focusing on artifact reduction, signal-to-noise ratio (SNR) improvement, and lesion detectability. STUDY TYPE Meta-analysis. POPULATION Systematic literature search was conducted in PubMed, Embase, the Cochrane Library, and Web of Science ending in January 2024. Thirteen studies with 765 participants focusing on DWI quality using rFOV was analyzed. FIELD STRENGTH/SEQUENCE SS-EPI, Rtr-SS-EPI, 2D-SS-EPI at 3.0 T. ASSESSMENT Two investigators performed the data extraction. QUADAS-2 assessed bias. The image quality assessment of rFOV and fFOV DWI were compared. STATISTICAL TESTS Standardized mean difference (SMD) was utilized to evaluate and standardize MRI image quality. Heterogeneity was assessed using the I2 statistic and publication bias was evaluated with Egger's test. RESULTS The QUADAS-2 analysis revealed that most studies exhibited a low risk of bias and minimal concerns regarding applicability. Statistical analysis indicated that rFOV DWI yielded higher subjective image quality scores (SMD = 0.535, 95% CI: 0.339, 0.731, I2 = 45.7%) compared with fFOV DWI and was more effective in reducing artifacts (SMD = 0.44, 95% CI: 0.209, 0.672, I2 = 42.3%) than fFOV DWI. However, a decrease in SNR was noted with rFOV DWI (SMD = -0.670, 95% CI: -1.187 to -0.152, I2 = 87.9%). Additionally, rFOV DWI demonstrated enhancements in lesion visibility (SMD = 0.432, 95% CI: -1.187, -0.152, I2 = 53.1%) and anatomical details (SMD = 0.598, 95% CI: 0.121, 1.075, I2 = 90.8%). DATA CONCLUSION rFOV DWI enhances MRI image quality by reducing artifacts and improving lesion visibility with a SNR trade-off. EVIDENCE LEVEL 3 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Jingjing Shi
- Department of Radiology, The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, China
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, China
| | - Jie Lin
- Department of Radiology, The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, China
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, China
| | - Xinbin Zhou
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, China
- Department of Cardiology, The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, China
| | - Ningbo Yin
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, China
| | - Liyi Wu
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, China
| | - Mei Yu
- The Xiaoshan Hospital Affiliated of Wenzhou Medical University, Xiaoshan First People's Hospital, Hangzhou, China
| | - Maosheng Xu
- Department of Radiology, The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, China
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, China
| |
Collapse
|
11
|
Deveshwar N, Yao J, Han M, Dwork N, Shen X, Ljungberg E, Caverzasi E, Cao P, Henry R, Green A, Larson PEZ. Quantification of the in vivo brain ultrashort-T 2* component in healthy volunteers. Magn Reson Med 2024; 91:2417-2430. [PMID: 38291598 DOI: 10.1002/mrm.30013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 12/14/2023] [Accepted: 12/29/2023] [Indexed: 02/01/2024]
Abstract
PURPOSE Recent work has shown MRI is able to measure and quantify signals of phospholipid membrane-bound protons associated with myelin in the human brain. This work seeks to develop an improved technique for characterizing this brain ultrashort-T 2 ∗ $$ {\mathrm{T}}_2\ast $$ component in vivo accounting forT 1 $$ {\mathrm{T}}_1 $$ weighting. METHODS Data from ultrashort echo time scans from 16 healthy volunteers with variable flip angles (VFA) were collected and fitted into an advanced regression model to quantify signal fraction, relaxation time, and frequency shift of the ultrashort-T 2 ∗ $$ {\mathrm{T}}_2\ast $$ component. RESULTS The fitted components show intra-subject differences of different white matter structures and significantly elevated ultrashort-T 2 ∗ $$ {\mathrm{T}}_2\ast $$ signal fraction in the corticospinal tracts measured at 0.09 versus 0.06 in other white matter structures and significantly elevated ultrashort-T 2 ∗ $$ {\mathrm{T}}_2\ast $$ frequency shift in the body of the corpus callosum at- $$ - $$ 1.5 versus- $$ - $$ 2.0 ppm in other white matter structures. CONCLUSION The significantly different measured components and measuredT 1 $$ {\mathrm{T}}_1 $$ relaxation time of the ultrashort-T 2 ∗ $$ {\mathrm{T}}_2\ast $$ component suggest that this method is picking up novel signals from phospholipid membrane-bound protons.
Collapse
Affiliation(s)
- Nikhil Deveshwar
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, USA
- UC Berkeley - UCSF Graduate Program in Bioengineering, San Francisco, California, USA
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, Berkeley, California, USA
| | - Jingwen Yao
- UC Berkeley - UCSF Graduate Program in Bioengineering, San Francisco, California, USA
| | - Misung Han
- UC Berkeley - UCSF Graduate Program in Bioengineering, San Francisco, California, USA
| | - Nicholas Dwork
- Departments of Biomedical Informatics and Radiology, University of Colorado School of Medicine, Aurora, Colorado, USA
| | - Xin Shen
- UC Berkeley - UCSF Graduate Program in Bioengineering, San Francisco, California, USA
| | - Emil Ljungberg
- Department of Medical Radiation Physics, Lund University, Lund, Sweden
| | - Eduardo Caverzasi
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, USA
| | - Peng Cao
- Department of Diagnostic Radiology, Hong Kong University, Hong Kong, China
| | - Roland Henry
- Department of Neurology, University of California, San Francisco, San Francisco, California, USA
| | - Ari Green
- Department of Neurology, University of California, San Francisco, San Francisco, California, USA
| | - Peder E Z Larson
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, USA
- UC Berkeley - UCSF Graduate Program in Bioengineering, San Francisco, California, USA
| |
Collapse
|
12
|
Dong Z, Reese TG, Lee HH, Huang SY, Polimeni JR, Wald LL, Wang F. Romer-EPTI: rotating-view motion-robust super-resolution EPTI for SNR-efficient distortion-free in-vivo mesoscale dMRI and microstructure imaging. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.01.26.577343. [PMID: 38352481 PMCID: PMC10862730 DOI: 10.1101/2024.01.26.577343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 02/19/2024]
Abstract
Purpose To overcome the major challenges in dMRI acquisition, including low SNR, distortion/blurring, and motion vulnerability. Methods A novel Romer-EPTI technique is developed to provide distortion-free dMRI with significant SNR gain, high motion-robustness, sharp spatial resolution, and simultaneous multi-TE imaging. It introduces a ROtating-view Motion-robust supEr-Resolution technique (Romer) combined with a distortion/blurring-free EPTI encoding. Romer enhances SNR by a simultaneous multi-thick-slice acquisition with rotating-view encoding, while providing high motion-robustness through a motion-aware super-resolution reconstruction, which also incorporates slice-profile and real-value diffusion, to resolve high-isotropic-resolution volumes. The in-plane encoding is performed using distortion/blurring-free EPTI, which further improves effective spatial resolution and motion robustness by preventing not only T2/T2*-blurring but also additional blurring resulting from combining encoded volumes with inconsistent geometries caused by dynamic distortions. Self-navigation was incorporated to enable efficient phase correction. Additional developments include strategies to address slab-boundary artifacts, achieve minimal TE for SNR gain at 7T, and achieve high robustness to strong phase variations at high b-values. Results Using Romer-EPTI, we demonstrate distortion-free whole-brain mesoscale in-vivo dMRI at both 3T (500-μm-iso) and 7T (485-μm-iso) for the first time, with high SNR efficiency (e.g., 25 × ), and high image quality free from distortion and slab-boundary artifacts with minimal blurring. Motion experiments demonstrate Romer-EPTI's high motion-robustness and ability to recover sharp images in the presence of motion. Romer-EPTI also demonstrates significant SNR gain and robustness in high b-value (b=5000s/mm2) and time-dependent dMRI. Conclusion Romer-EPTI significantly improves SNR, motion-robustness, and image quality, providing a highly efficient acquisition for high-resolution dMRI and microstructure imaging.
Collapse
Affiliation(s)
- Zijing Dong
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Timothy G. Reese
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Hong-Hsi Lee
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Susie Y. Huang
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
- Harvard-MIT Health Sciences and Technology, MIT, Cambridge, Massachusetts, USA
| | - Jonathan R. Polimeni
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
- Harvard-MIT Health Sciences and Technology, MIT, Cambridge, Massachusetts, USA
| | - Lawrence L. Wald
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
- Harvard-MIT Health Sciences and Technology, MIT, Cambridge, Massachusetts, USA
| | - Fuyixue Wang
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
13
|
Ye Z, Yao S, Yang T, Li Q, Li Z, Song B. Abdominal Diffusion-Weighted MRI With Simultaneous Multi-Slice Acquisition: Agreement and Reproducibility of Apparent Diffusion Coefficients Measurements. J Magn Reson Imaging 2024; 59:1170-1178. [PMID: 37334872 DOI: 10.1002/jmri.28876] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Revised: 06/07/2023] [Accepted: 06/07/2023] [Indexed: 06/21/2023] Open
Abstract
BACKGROUND Simultaneous multi-slice diffusion-weighted imaging (SMS-DWI) can shorten acquisition time in abdominal imaging. PURPOSE To investigate the agreement and reproducibility of apparent diffusion coefficient (ADC) from abdominal SMS-DWI acquired with different vendors and different breathing schemes. STUDY TYPE Prospective. SUBJECTS Twenty volunteers and 10 patients. FIELD STRENGTH/SEQUENCE 3.0 T, SMS-DWI with a diffusion-weighted echo-planar imaging sequence. ASSESSMENT SMS-DWI was acquired using breath-hold and free-breathing techniques in scanners from two vendors, yielding four scans in each participant. Average ADC values were measured in the liver, pancreas, spleen, and both kidneys. Non-normalized ADC and ADCs normalized to the spleen were compared between vendors and breathing schemes. STATISTICAL TESTS Paired t-test or Wilcoxon signed rank test; intraclass correlation coefficient (ICC); Bland-Altman method; coefficient of variation (CV) analysis; significance level: P < 0.05. RESULTS Non-normalized ADCs from the four SMS-DWI scans did not differ significantly in the spleen (P = 0.262, 0.330, 0.166, 0.122), right kidney (P = 0.167, 0.538, 0.957, 0.086), and left kidney (P = 0.182, 0.281, 0.504, 0.405), but there were significant differences in the liver and pancreas. For normalized ADCs, there were no significant differences in the liver (P = 0.315, 0.915, 0.198, 0.799), spleen (P = 0.815, 0.689, 0.347, 0.423), pancreas (P = 0.165, 0.336, 0.304, 0.584), right kidney (P = 0.165, 0.336, 0.304, 0.584), and left kidney (P = 0.496, 0.304, 0.443, 0.371). Inter-reader agreements of non-normalized ADCs were good to excellent (ICCs ranged from 0.861 to 0.983), and agreement and reproducibility were good to excellent depending on anatomic location (CVs ranged from 3.55% to 13.98%). Overall CVs for abdominal ADCs from the four scans were 6.25%, 7.62%, 7.08, and 7.60%. DATA CONCLUSION The normalized ADCs from abdominal SMS-DWI may be comparable between different vendors and breathing schemes, showing good agreement and reproducibility. ADC changes above approximately 8% may potentially be considered as a reliable quantitative biomarker to assess disease or treatment-related changes. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Zheng Ye
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Shan Yao
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Ting Yang
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Qing Li
- MR Collaborations, Siemens Healthineers, Shanghai, China
| | - Zhenlin Li
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Bin Song
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
- Department of Radiology, Sanya People's Hospital, Sanya, China
| |
Collapse
|
14
|
Xiong F, Emrich T, Schoepf UJ, Jin N, Hall S, Ruddy JM, Giese D, Lautenschlager C, Emrich AL, Varga-Szemes A. Highly accelerated free-breathing real-time 2D flow imaging using compressed sensing and shared velocity encoding. Eur Radiol 2024; 34:1692-1703. [PMID: 37658887 DOI: 10.1007/s00330-023-10157-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 07/13/2023] [Accepted: 07/17/2023] [Indexed: 09/05/2023]
Abstract
OBJECTIVES 2D real-time (RT) phase-contrast (PC) MRI is a promising alternative to conventional PC MRI, which overcomes problems due to irregular heartbeats or poor respiratory control. This study aims to evaluate a prototype compressed sensing (CS)-accelerated 2D RT-PC MRI technique with shared velocity encoding (SVE) for accurate beat-to-beat flow measurements. METHODS The CS RT-PC technique was implemented using a single-shot fast RF-spoiled gradient echo with SVE by symmetric velocity encoding, and acquired with a temporal resolution of 51-56.5 ms in 1-5 heartbeats. Both aortic dissection phantom (n = 8) and volunteer (n = 7) studies were conducted using the prototype CS RT (CS, R = 8), the conventional (GRAPPA, R = 2), and the fully sampled PC sequences on a 3T clinical system. Flow parameters including peak velocity, peak flow rate, net flow rate, and maximum velocity were calculated to compare the performance between different methods using linear regression, intraclass correlation (ICC), and Bland-Altman analyses. RESULTS Comparisons of the flow measurements at all locations in the phantoms demonstrated an excellent correlation (all R2 ≥ 0.93) and agreement (all ICC ≥ 0.97) with negligible means of differences. In healthy volunteers, a similarly good correlation (all R2 ≥ 0.80) and agreement (all ICC ≥ 0.90) were observed; however, CS RT slightly underestimated the maximum velocities and flow rates (~ 12%). CONCLUSION The highly accelerated CS RT-PC technique is feasible for the evaluation of flow patterns without requiring breath-holding, and it allows for rapid flow assessment in patients with arrhythmia or poor breath-hold capacity. CLINICAL RELEVANCE STATEMENT The free-breathing real-time flow MRI technique offers improved spatial and temporal resolutions, as well as the ability to image individual cardiac cycles, resulting in superior image quality compared to the conventional PC technique when imaging patients with arrhythmias, especially those with atrial fibrillation. KEY POINTS • The highly accelerated prototype CS RT-PC MRI technique with improved temporal resolution by the concept of SVE is feasible for beat-to-beat flow evaluation without requiring breath-holding. • The results of the phantom and in vivo quantitative flow evaluation show the ability of the prototype CS RT-PC technique to obtain reliable flow measurements similarly to the conventional PC MRI. • With less than 12% underestimation, excellent agreements between the two techniques were shown for the measurements of peak velocities and flow rates.
Collapse
Affiliation(s)
- Fei Xiong
- Siemens Medical Solutions USA Inc, Cardiovascular MR R&D, Chicago, IL, USA
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, MSC 226, Charleston, SC, 29425-2260, USA
| | - Tilman Emrich
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, MSC 226, Charleston, SC, 29425-2260, USA
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
- German Centre for Cardiovascular Research, Partner Site Rhine-Main, Mainz, Germany
| | - U Joseph Schoepf
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, MSC 226, Charleston, SC, 29425-2260, USA.
| | - Ning Jin
- Siemens Medical Solutions USA Inc, Cardiovascular MR R&D, Chicago, IL, USA
| | - SarahRose Hall
- Division of Vascular Surgery, Department of Surgery, Medical University of South Carolina, Charleston, SC, USA
| | - Jean Marie Ruddy
- Division of Vascular Surgery, Department of Surgery, Medical University of South Carolina, Charleston, SC, USA
| | | | - Carla Lautenschlager
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, MSC 226, Charleston, SC, 29425-2260, USA
| | - Anna Lena Emrich
- Division of Cardiothoracic Surgery, Department of Surgery, Medical University of South Carolina, Charleston, SC, USA
- Department of Cardiac and Vascular Surgery, University Medical Center Mainz, Mainz, Germany
| | - Akos Varga-Szemes
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, MSC 226, Charleston, SC, 29425-2260, USA
| |
Collapse
|
15
|
Zhao W, Ju S, Yang H, Wang Q, Fang L, Pylypenko D, Wang W. Improved Value of Multiplexed Sensitivity Encoding DWI with Reversed Polarity Gradients in Diagnosing Prostate Cancer: A Comparison Study with Single-Shot DWI and MUSE DWI. Acad Radiol 2024; 31:909-920. [PMID: 37778902 DOI: 10.1016/j.acra.2023.08.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 08/16/2023] [Accepted: 08/21/2023] [Indexed: 10/03/2023]
Abstract
RATIONALE AND OBJECTIVES This study aimed to investigate the value of multiplexed sensitivity encoding with reversed polarity gradients in improving the quality of diffusion-weighted imaging (DWI) images of the prostate and the diagnostic efficacy of prostate cancer. MATERIALS AND METHODS Seventy-three patients with prostate disease underwent multiplexed sensitivity encoding with reversed polarity gradients (RPG-MUSE), multiplexed sensitivity encoding (MUSE), and single-shot echo-planar imaging (ssEPI) DWI. Three radiologists performed a qualitative image analysis of the three DWI sequences. Qualitative image analysis included artifact minimization, anatomical detail, and sharpness of prostate edges. Two radiologists measured the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), geometric distortion rate, and the apparent diffusion coefficient (ADC) values of the prostate disease tissue. Two radiologists jointly performed Prostate Imaging Reporting and Data System scoring of prostate lesions and compared the diagnostic efficacy of the three DWI sequences for prostate cancer. RESULTS There was good agreement among radiologists in the evaluation and measurement of the three DWI sequence images (intraclass correlation coefficient >0.75, P < 0.05). The RPG-MUSE DWI images were rated higher than those of MUSE and ssEPI in terms of artifact minimization, anatomical details, and sharpness of prostate edges (P < 0.05). The SNR and CNR of the RPG-MUSE DWI images were higher than those of MUSE and ssEPI (P < 0.05), and the geometric distortion rate was lower than that of the other two sequences (P < 0.05). There were no statistical differences in ADC values between the three DWI sequences (P > 0.05). The diagnostic efficacy of RPG-MUSE and MUSE DWI was higher than that of ssEPI (P < 0.017). CONCLUSION RPG-MUSE can reduce the artifacts and geometric distortion in DWI images of the prostate, improve the SNR and CNR of the images, improve the clarity of anatomical details and boundaries without affecting the measurement of ADC values, has the potential to improve the diagnostic efficacy of prostate lesions, and facilitates the clear display and accurate assessment of prostate lesions.
Collapse
Affiliation(s)
- Wenjing Zhao
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, China (W.Z., S.J., H.Y., Q.W., L.F., W.W.)
| | - Shiying Ju
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, China (W.Z., S.J., H.Y., Q.W., L.F., W.W.)
| | - Hongyang Yang
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, China (W.Z., S.J., H.Y., Q.W., L.F., W.W.)
| | - Qi Wang
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, China (W.Z., S.J., H.Y., Q.W., L.F., W.W.)
| | - Longjiang Fang
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, China (W.Z., S.J., H.Y., Q.W., L.F., W.W.)
| | | | - Wenjuan Wang
- Department of Radiology, Weifang People's Hospital, Weifang, Shandong, China (W.Z., S.J., H.Y., Q.W., L.F., W.W.).
| |
Collapse
|
16
|
Wang X, Wang P, Zhang H, Wang X, Shi J, Hu S. Multiplexed sensitivity-encoding versus single-shot echo-planar imaging: a comparative study for diffusion-weighted imaging of the thyroid lesions. Jpn J Radiol 2024; 42:268-275. [PMID: 37819591 DOI: 10.1007/s11604-023-01500-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 09/26/2023] [Indexed: 10/13/2023]
Abstract
PURPOSE To compare multiplexed sensitivity-encoding diffusion-weighted magnetic resonance imaging (MUSE-DWI) and conventional DWI (cDWI) techniques in thyroid MRI. MATERIALS AND METHODS Nineteen patients who underwent thyroid MRI using both MUSE-DWI and cDWI at a 3.0 T MRI system were enrolled. Qualitative parameters (image quality, thyroid contour, and lesion conspicuity) and quantitative parameters (signal-to-noise ratio (SNR), lesion-to-thyroid contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC)) were compared between the two sequences. In addition, ADC values derived from MUSE-DWI and cDWI were separately compared between benign and malignant lesions. RESULTS MUSE-DWI outperformed cDWI in terms of image quality, thyroid contour, and lesion conspicuity. Significantly, higher signal-to-noise ratio (SNR) in both the thyroid and its lesion were found in MUSE-DWI than those in cDWI (both P < 0.05). The lesion-to-thyroid contrast-to-noise ratio (CNR) values were also significantly higher in MUSE-DWI than those in cDWI (P < 0.05). The apparent diffusion coefficient (ADC) of the thyroid in MUSE-DWI was significantly lower than that in cDWI (P < 0.05). The ADC of the lesion in MUSE-DWI was also significantly lower than that in cDWI (P < 0.05). In addition, ADC values derived from MUSE-DWI and cDWI were significantly higher in benign lesions than malignant lesions (P < 0.05). CONCLUSION Compared with cDWI, MUSE-DWI can improve the image quality, thyroid contour sharpness, lesion conspicuity, SNR in both the thyroid and its lesions, and enhancing the CNR between lesions and thyroid.
Collapse
Affiliation(s)
- Xiuyu Wang
- Department of Radiology, Affiliated Hospital, Jiangnan University, No.1000, Hefeng Road, Wuxi, 214000, Jiangsu, China
| | - Peng Wang
- Department of Radiology, Affiliated Hospital, Jiangnan University, No.1000, Hefeng Road, Wuxi, 214000, Jiangsu, China
| | - Heng Zhang
- Department of Radiology, Affiliated Hospital, Jiangnan University, No.1000, Hefeng Road, Wuxi, 214000, Jiangsu, China
| | - Xian Wang
- Department of Radiology, Affiliated Renmin Hospital, Jiangsu University, No.8, Dianli Road, Zhenjiang, 212000, Jiangsu, China
| | - Jie Shi
- GE Healthcare, Beijing, 100000, China
| | - Shudong Hu
- Department of Radiology, Affiliated Hospital, Jiangnan University, No.1000, Hefeng Road, Wuxi, 214000, Jiangsu, China.
| |
Collapse
|
17
|
Mao L, Li Y, Cui B, Lu L, Dou W, Pylypenko D, Zhu J, Li H. Multiparametric MRI for Staging of Bowel Inflammatory Activity in Crohn's Disease with MUSE-IVIM and DCE-MRI: A Preliminary Study. Acad Radiol 2024; 31:880-888. [PMID: 37730492 DOI: 10.1016/j.acra.2023.08.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Revised: 08/20/2023] [Accepted: 08/23/2023] [Indexed: 09/22/2023]
Abstract
RATIONALE AND OBJECTIVES To investigate if the combination of multishot diffusion imaging-based multiplexed sensitivity encoding intravoxel incoherent motion (MUSE-IVIM) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is feasible for staging Crohn's disease (CD) activity. MATERIALS AND METHODS A total of 65 CD patients were enrolled and analyzed in this retrospective study. The simplified endoscopic score for Crohn's disease (SES-CD) and magnetic resonance index of activity (MaRIA) were used as the reference. The MUSE-IVIM and DCE-MRI data were acquired at 3.0-T MRI scanner and processed by two radiologists. Three MUSE-IVIM parameters: fast apparent diffusion coefficient (ADCfast), slow apparent diffusion coefficient (ADCslow), and the fractional perfusion (Fraction of ADCfast), as well as four DCE-MRI parameters: volume transfer constant (Ktrans), rate constant (Kep), extravascular extracellular volume fraction (Ve), and plasma volume fraction (Vp) were generated. Intraclass correlation coefficient (ICC), non-parametric test (Kruskal-Wallis H and Mann-Whitney U), logistic regression, receiver operating characteristic analysis, Delong test, and Spearman's correlation test were performed. RESULTS According to SES-CD, 116 ileocolonic segments with CD lesions were identified as: inactive, mild, and moderate to severe. With multivariable logistic regression analysis, ADCfast (p < 0.001), Fraction of ADCfast (p = 0.005), Ktrans (p < 0.001) and Kep (p = 0.003) were identified as significant factors for differentiating among the three groups. Binary logistic analyses identified ADCfast (p = 0.001), Ktrans (p = 0.014), and Kep (p = 0.029) as independent predictors for the active status. The combination of ADCfast, Ktrans, and Kep performed better than MaRIA score (p = 0.028), for differentiating inactive and active status. MaRIA score was positively correlated with ADCfast (p < 0.001), Ktrans (p < 0.001), Kep (p < 0.001), and Ve (p = 0.001), however, negatively correlated with Fraction of ADCfast (p < 0.001). CONCLUSION The combination of MUSE-IVIM and DCE-MRI has been demonstrated to accurately stage inflammatory activity in CD.
Collapse
Affiliation(s)
- Liangqiang Mao
- Department of Radiology, the Second Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| | - Yan Li
- Department of Radiology, the Second Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| | - Bota Cui
- Department of Gastroenterology, the Second Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| | - Lin Lu
- Department of Radiology, Columbia University Medical Center, New York, New York
| | - Weiqiang Dou
- GE Healthcare, MR Research China, Beijing, PR China
| | | | - Jianguo Zhu
- Department of Radiology, the Second Affiliated Hospital of Nanjing Medical University, Nanjing, PR China.
| | - Haige Li
- Department of Radiology, the Second Affiliated Hospital of Nanjing Medical University, Nanjing, PR China
| |
Collapse
|
18
|
Liu YJ, Tsai TS, Li YH, Peng JH, Chang HC, Peng HH, Lee YC, Lee TY, Liou CH, Lin TF, Chew FY, Chou RH, Juan CJ. Understanding ADC variation by fat content effect using a dual-function MRI phantom. Eur Radiol Exp 2024; 8:19. [PMID: 38347188 PMCID: PMC10861416 DOI: 10.1186/s41747-023-00414-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 11/14/2023] [Indexed: 02/15/2024] Open
Abstract
BACKGROUND A dual-function phantom designed to quantify the apparent diffusion coefficient (ADC) in different fat contents (FCs) and glass bead densities (GBDs) to simulate the human tissues has not been documented yet. We propose a dual-function phantom to quantify the FC and to measure the ADC at different FCs and different GBDs. METHODS A fat-containing diffusion phantom comprised by 30 glass-bead-containing fat-water emulsions consisting of six different FCs (0, 10, 20, 30, 40, and 50%) multiplied by five different GBDs (0, 0.1, 0.25, 0.5, and 1.0 g/50 mL). The FC and ADC were measured by the "iterative decomposition of water and fat with echo asymmetry and least squares estimation-IQ," IDEAL-IQ, and single-shot echo-planar diffusion-weighted imaging, SS-EP-DWI, sequences, respectively. Linear regression analysis was used to evaluate the relationship among the fat fraction (FF) measured by IDEAL-IQ, GBD, and ADC. RESULTS The ADC was significantly, negatively, and linearly associated with the FF (the linear slope ranged from -0.005 to -0.017, R2 = 0.925 to 0.986, all p < 0.001). The slope of the linear relationship between the ADC and the FF, however, varied among different GBDs (the higher the GBD, the lower the slope). ADCs among emulsions across different GBDs and FFs were overlapped. Emulsions with low GBDs plus high FFs shared a same lower ADC range with those with median or high GBDs plus median or lower FFs. CONCLUSIONS A novel dual-function phantom simulating the human tissues allowed to quantify the influence of FC and GBD on ADC. RELEVANCE STATEMENT The study developed an innovative dual-function MRI phantom to explore the impact of FC on ADC variation that can affect clinical results. The results revealed the superimposed effect on FF and GBD density on ADC measurements. KEY POINTS • A dual-function phantom made of glass bead density (GBD) and fat fraction (FF) emulsion has been developed. • Apparent diffusion coefficient (ADC) values are determined by GBD and FF. • The dual-function phantom showed the mutual ADC addition between FF and GBD.
Collapse
Affiliation(s)
- Yi-Jui Liu
- Department of Automatic Control Engineering, Feng Chia University, Taichung, Taiwan, Republic of China
| | - Tung-Sheng Tsai
- Ph.D. Program in Electrical and Communication Engineering, Feng Chia University, Taichung, Taiwan, Republic of China
| | - Ya-Hui Li
- Department of Medical Imaging, China Medical University Hsinchu Hospital, 199, Sec. 1, Xinglong Rd., Zhubei City, Hsinchu County, 302, Taiwan, Republic of China
| | - Jo-Hua Peng
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan, Republic of China
| | - Hing-Chiu Chang
- Department of Biomedical Engineering, Chinese University of Hong Kong, Hong Kong, China
| | - Hsu-Hsia Peng
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan, Republic of China
| | - Ying-Chieh Lee
- Department of Automatic Control Engineering, Feng Chia University, Taichung, Taiwan, Republic of China
| | - Tung-Yang Lee
- Master's Program of Biomedical Informatics and Biomedical Engineering, Feng Chia University, Taichung, Taiwan, Republic of China
- Cheng Ching Hospital, Taichung, Taiwan, Republic of China
| | - Chang-Hsien Liou
- Department of Medical Imaging, China Medical University Hsinchu Hospital, 199, Sec. 1, Xinglong Rd., Zhubei City, Hsinchu County, 302, Taiwan, Republic of China
- Institute of Nuclear Engineering and Science, National Tsing Hua University, Hsinchu, Taiwan, Republic of China
| | - Tz-Feng Lin
- Department of Fiber and Composite Materials, Feng Chia University, Taichung, Taiwan, Republic of China
| | - Fatt-Yang Chew
- Department of Medical Imaging, China Medical University Hospital, Taichung, Taiwan, Republic of China
- Department of Radiology, School of Medicine, China Medical University, Taichung, Taiwan, Republic of China
| | - Ruey-Hwang Chou
- Graduate Institute of Biomedical Sciences, China Medical University, Taichung, 406, Taiwan, Republic of China.
- Center for Molecular Medicine, China Medical University Hospital, Taichung, Taiwan, Republic of China.
- Department of Medical Laboratory and Biotechnology, Asia University, Taichung, Taiwan, Republic of China.
| | - Chun-Jung Juan
- Department of Medical Imaging, China Medical University Hsinchu Hospital, 199, Sec. 1, Xinglong Rd., Zhubei City, Hsinchu County, 302, Taiwan, Republic of China.
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan, Republic of China.
- Department of Radiology, School of Medicine, China Medical University, Taichung, Taiwan, Republic of China.
| |
Collapse
|
19
|
Labbène E, Mahmoud M, Marrakchi-Kacem L, Ben Hamouda M. Prognostic value of preoperative diffusion restriction in glioblastoma. LA TUNISIE MEDICALE 2024; 102:94-99. [PMID: 38567475 PMCID: PMC11358806 DOI: 10.62438/tunismed.v102i2.4746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Accepted: 02/13/2024] [Indexed: 04/04/2024]
Abstract
INTRODUCTION Although glioblastoma (GBM) has a very poor prognosis, overall survival (OS) in treated patients shows great difference varying from few days to several months. Identifying factors explaining this difference would improve management of patient treatment. AIM To determine the relevance of diffusion restriction in newly diagnosed treatment-naïve GBM patients. METHODS Preoperative magnetic resonance scans of 33 patients with GBM were reviewed. Regions of interest including all the T2 hyperintense lesion were drawn on diffusion weighted B0 images and transferred to the apparent diffusion coefficient (ADC) map. For each patient, a histogram displaying the ADC values within in the regions of interest was generated. Volumetric parameters including tumor regions with restricted diffusion, parameters derived from histogram and mean ADC value of the tumor were calculated. Their relationship with OS was analyzed. RESULTS Patients with mean ADC value < 1415x10-6 mm2/s had a significantly shorter OS (p=0.021). Among volumetric parameters, the percentage of volume within T2 lesion with a normalized ADC value <1.5 times that in white matter was significantly associated with OS (p=0.0045). Patients with a percentage>23.92% had a shorter OS. Among parameters derived from histogram, the 50th percentile showed a trend towards significance for OS (p=0.055) with patients living longer when having higher values of 50th percentile. A difference in OS was observed between patients according to ADC peak of histogram but this difference did not reach statistical significance (p=0.0959). CONCLUSION Diffusion magnetic resonance imaging may provide useful information for predicting GBM prognosis.
Collapse
Affiliation(s)
- Emna Labbène
- Department of radiology, MT Kassab institute of orthopaedics, Tunis, Tunisia
- Faculty of medicine of Tunis, Tunis-El Manar University, Tunis, Tunisia
| | - Maha Mahmoud
- Faculty of medicine of Tunis, Tunis-El Manar University, Tunis, Tunisia
- Department of neuroradiology, National institute of neurology Mongi-Ben Hamida, Tunis, Tunisia
| | - Linda Marrakchi-Kacem
- Higher institute of biotechnology of Sidi Thabet, Manouba University, Tunis, Tunisia
- National engineering school of Tunis (ENIT), L3S laboratory, Tunis-El Manar University, Tunis, Tunisia
| | - Mohamed Ben Hamouda
- Faculty of medicine of Tunis, Tunis-El Manar University, Tunis, Tunisia
- Department of neuroradiology, National institute of neurology Mongi-Ben Hamida, Tunis, Tunisia
| |
Collapse
|
20
|
Barrett T, Lee KL, de Rooij M, Giganti F. Update on Optimization of Prostate MR Imaging Technique and Image Quality. Radiol Clin North Am 2024; 62:1-15. [PMID: 37973236 DOI: 10.1016/j.rcl.2023.06.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
Abstract
Prostate MR imaging quality has improved dramatically over recent times, driven by advances in hardware, software, and improved functional imaging techniques. MRI now plays a key role in prostate cancer diagnostic work-up, but outcomes of the MRI-directed pathway are heavily dependent on image quality and optimization. MR sequences can be affected by patient-related degradations relating to motion and susceptibility artifacts which may enable only partial mitigation. In this Review, we explore issues relating to prostate MRI acquisition and interpretation, mitigation strategies at a patient and scanner level, PI-QUAL reporting, and future directions in image quality, including artificial intelligence solutions.
Collapse
Affiliation(s)
- Tristan Barrett
- Department of Radiology, Addenbrooke's Hospital and University of Cambridge, Cambridge, UK.
| | - Kang-Lung Lee
- Department of Radiology, Addenbrooke's Hospital and University of Cambridge, Cambridge, UK; Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan; School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Maarten de Rooij
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, Netherlands
| | - Francesco Giganti
- Department of Radiology, University College London Hospital NHS Foundation Trust, London, UK; Division of Surgery and Interventional Science, University College London, London, UK
| |
Collapse
|
21
|
Wilpert C, Neubauer C, Rau A, Schneider H, Benkert T, Weiland E, Strecker R, Reisert M, Benndorf M, Weiss J, Bamberg F, Windfuhr-Blum M, Neubauer J. Accelerated Diffusion-Weighted Imaging in 3 T Breast MRI Using a Deep Learning Reconstruction Algorithm With Superresolution Processing: A Prospective Comparative Study. Invest Radiol 2023; 58:842-852. [PMID: 37428618 DOI: 10.1097/rli.0000000000000997] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/12/2023]
Abstract
OBJECTIVES Diffusion-weighted imaging (DWI) enhances specificity in multiparametric breast MRI but is associated with longer acquisition time. Deep learning (DL) reconstruction may significantly shorten acquisition time and improve spatial resolution. In this prospective study, we evaluated acquisition time and image quality of a DL-accelerated DWI sequence with superresolution processing (DWI DL ) in comparison to standard imaging including analysis of lesion conspicuity and contrast of invasive breast cancers (IBCs), benign lesions (BEs), and cysts. MATERIALS AND METHODS This institutional review board-approved prospective monocentric study enrolled participants who underwent 3 T breast MRI between August and December 2022. Standard DWI (DWI STD ; single-shot echo-planar DWI combined with reduced field-of-view excitation; b-values: 50 and 800 s/mm 2 ) was followed by DWI DL with similar acquisition parameters and reduced averages. Quantitative image quality was analyzed for region of interest-based signal-to-noise ratio (SNR) on breast tissue. Apparent diffusion coefficient (ADC), SNR, contrast-to-noise ratio, and contrast (C) values were calculated for biopsy-proven IBCs, BEs, and for cysts. Two radiologists independently assessed image quality, artifacts, and lesion conspicuity in a blinded independent manner. Univariate analysis was performed to test differences and interrater reliability. RESULTS Among 65 participants (54 ± 13 years, 64 women) enrolled in the study, the prevalence of breast cancer was 23%. Average acquisition time was 5:02 minutes for DWI STD and 2:44 minutes for DWI DL ( P < 0.001). Signal-to-noise ratio measured in breast tissue was higher for DWI STD ( P < 0.001). The mean ADC values for IBC were 0.77 × 10 -3 ± 0.13 mm 2 /s in DWI STD and 0.75 × 10 -3 ± 0.12 mm 2 /s in DWI DL without significant difference when sequences were compared ( P = 0.32). Benign lesions presented with mean ADC values of 1.32 × 10 -3 ± 0.48 mm 2 /s in DWI STD and 1.39 × 10 -3 ± 0.54 mm 2 /s in DWI DL ( P = 0.12), and cysts presented with 2.18 × 10 -3 ± 0.49 mm 2 /s in DWI STD and 2.31 × 10 -3 ± 0.43 mm 2 /s in DWI DL . All lesions presented with significantly higher contrast in the DWI DL ( P < 0.001), whereas SNR and contrast-to-noise ratio did not differ significantly between DWI STD and DWI DL regardless of lesion type. Both sequences demonstrated a high subjective image quality (29/65 for DWI STD vs 20/65 for DWI DL ; P < 0.001). The highest lesion conspicuity score was observed more often for DWI DL ( P < 0.001) for all lesion types. Artifacts were scored higher for DWI DL ( P < 0.001). In general, no additional artifacts were noted in DWI DL . Interrater reliability was substantial to excellent (k = 0.68 to 1.0). CONCLUSIONS DWI DL in breast MRI significantly reduced scan time by nearly one half while improving lesion conspicuity and maintaining overall image quality in a prospective clinical cohort.
Collapse
Affiliation(s)
- Caroline Wilpert
- From the Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany (C.W., C.N., A.R., H.S., M.B., JW, F.B., M.W.-B., J.N.); MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany (T.B., E.W.); EMEA Scientific Partnerships, Siemens Healthcare GmbH, Erlangen, Germany (R.S.); Medical Physics, Department of Radiology, Medical Center, University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany (M.R.); and Department of Stereotactic and Functional Neurosurgery, Medical Center, University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany (M.R.)
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Calarco N, Oliver LD, Joseph M, Hawco C, Dickie EW, DeRosse P, Gold JM, Foussias G, Argyelan M, Malhotra AK, Buchanan RW, Voineskos AN. Multivariate Associations Among White Matter, Neurocognition, and Social Cognition Across Individuals With Schizophrenia Spectrum Disorders and Healthy Controls. Schizophr Bull 2023; 49:1518-1529. [PMID: 36869812 PMCID: PMC10686342 DOI: 10.1093/schbul/sbac216] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/05/2023]
Abstract
BACKGROUND AND HYPOTHESIS Neurocognitive and social cognitive abilities are important contributors to functional outcomes in schizophrenia spectrum disorders (SSDs). An unanswered question of considerable interest is whether neurocognitive and social cognitive deficits arise from overlapping or distinct white matter impairment(s). STUDY DESIGN We sought to fill this gap, by harnessing a large sample of individuals from the multi-center Social Processes Initiative in the Neurobiology of the Schizophrenia(s) (SPINS) dataset, unique in its collection of advanced diffusion imaging and an extensive battery of cognitive assessments. We applied canonical correlation analysis to estimates of white matter microstructure, and cognitive performance, across people with and without an SSD. STUDY RESULTS Our results established that white matter circuitry is dimensionally and strongly related to both neurocognition and social cognition, and that microstructure of the uncinate fasciculus and the rostral body of the corpus callosum may assume a "privileged role" subserving both. Further, we found that participant-wise estimates of white matter microstructure, weighted by cognitive performance, were largely consistent with participants' categorical diagnosis, and predictive of (cross-sectional) functional outcomes. CONCLUSIONS The demonstrated strength of the relationship between white matter circuitry and neurocognition and social cognition underscores the potential for using relationships among these variables to identify biomarkers of functioning, with potential prognostic and therapeutic implications.
Collapse
Affiliation(s)
- Navona Calarco
- Campbell Family Mental Health Research Institute, Centre for Addiction and Mental Health, Toronto, ON, Canada
| | - Lindsay D Oliver
- Campbell Family Mental Health Research Institute, Centre for Addiction and Mental Health, Toronto, ON, Canada
| | - Michael Joseph
- Campbell Family Mental Health Research Institute, Centre for Addiction and Mental Health, Toronto, ON, Canada
| | - Colin Hawco
- Campbell Family Mental Health Research Institute, Centre for Addiction and Mental Health, Toronto, ON, Canada
- Department of Psychiatry, University of Toronto, Toronto, ON, Canada
| | - Erin W Dickie
- Campbell Family Mental Health Research Institute, Centre for Addiction and Mental Health, Toronto, ON, Canada
| | - Pamela DeRosse
- Division of Psychiatry Research, Division of Northwell Health, The Zucker Hillside Hospital, Glen Oaks, NY, USA
- Department of Psychiatry, The Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, USA
- Center for Psychiatric Neuroscience, The Feinstein Institute for Medical Research, Manhasset, NY, USA
| | - James M Gold
- Department of Psychiatry, Maryland Psychiatric Research Center, University of Maryland School of Medicine, Baltimore, MD, USA
| | - George Foussias
- Campbell Family Mental Health Research Institute, Centre for Addiction and Mental Health, Toronto, ON, Canada
- Department of Psychiatry, University of Toronto, Toronto, ON, Canada
| | - Miklos Argyelan
- Division of Psychiatry Research, Division of Northwell Health, The Zucker Hillside Hospital, Glen Oaks, NY, USA
- Department of Psychiatry, The Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, USA
- Center for Psychiatric Neuroscience, The Feinstein Institute for Medical Research, Manhasset, NY, USA
| | - Anil K Malhotra
- Division of Psychiatry Research, Division of Northwell Health, The Zucker Hillside Hospital, Glen Oaks, NY, USA
- Department of Psychiatry, The Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, USA
- Center for Psychiatric Neuroscience, The Feinstein Institute for Medical Research, Manhasset, NY, USA
| | - Robert W Buchanan
- Department of Psychiatry, Maryland Psychiatric Research Center, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Aristotle N Voineskos
- Campbell Family Mental Health Research Institute, Centre for Addiction and Mental Health, Toronto, ON, Canada
- Department of Psychiatry, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
23
|
Switlyk MD, Hopland A, Reitan E, Sivanesan S, Brennhovd B, Axcrona U, Hole KH. Multiparametric Magnetic Resonance Imaging of Penile Cancer: A Pictorial Review. Cancers (Basel) 2023; 15:5324. [PMID: 38001583 PMCID: PMC10670261 DOI: 10.3390/cancers15225324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 11/03/2023] [Accepted: 11/06/2023] [Indexed: 11/26/2023] Open
Abstract
The role of multiparametric magnetic resonance imaging (mpMRI) in assessing penile cancer is not well defined. However, this modality may be successfully applied for preoperative staging and patient selection; postoperative local and regional surveillance; and assessments of treatment response after oncological therapies. Previous studies have been mostly limited to a few small series evaluating the accuracy of MRI for the preoperative staging of penile cancer. This review discusses the principles of non-erectile mpMRI, including functional techniques and their applications in evaluating the male genital region, along with clinical protocols and technical considerations. The latest clinical classifications and guidelines are reviewed, focusing on imaging recommendations and discussing potential gaps and disadvantages. The development of functional MRI techniques and the extraction of quantitative parameters from these sequences enables the noninvasive assessment of phenotypic and genotypic tumor characteristics. The applications of advanced techniques in penile MRI are yet to be defined. There is a need for prospective trials and feasible multicenter trials due to the rarity of the disease, highlighting the importance of minimum technical requirements for MRI protocols, particularly image resolution, and finally determining the role of mpMRI in the assessment of penile cancer.
Collapse
Affiliation(s)
- Marta D. Switlyk
- Department of Radiology, The Norwegian Radium Hospital, Oslo University Hospital, 0379 Oslo, Norway; (E.R.); (K.H.H.)
| | - Andreas Hopland
- Department of Urology, The Norwegian Radium Hospital, Oslo University Hospital, 0379 Oslo, Norway; (A.H.); (S.S.); (B.B.)
| | - Edmund Reitan
- Department of Radiology, The Norwegian Radium Hospital, Oslo University Hospital, 0379 Oslo, Norway; (E.R.); (K.H.H.)
| | - Shivanthe Sivanesan
- Department of Urology, The Norwegian Radium Hospital, Oslo University Hospital, 0379 Oslo, Norway; (A.H.); (S.S.); (B.B.)
- Institute of Clinical Medicine (KlinMED), Faculty of Medicine, University of Oslo, 0318 Oslo, Norway
| | - Bjørn Brennhovd
- Department of Urology, The Norwegian Radium Hospital, Oslo University Hospital, 0379 Oslo, Norway; (A.H.); (S.S.); (B.B.)
| | - Ulrika Axcrona
- Department of Pathology, The Norwegian Radium Hospital, Oslo University Hospital, 0379 Oslo, Norway;
| | - Knut H. Hole
- Department of Radiology, The Norwegian Radium Hospital, Oslo University Hospital, 0379 Oslo, Norway; (E.R.); (K.H.H.)
- Institute of Clinical Medicine (KlinMED), Faculty of Medicine, University of Oslo, 0318 Oslo, Norway
| |
Collapse
|
24
|
Beck KS, Chang S, Hyun K, Sung YE, Lee KY, Jung JI. T1 and T2 Mapping for Characterization of Mediastinal Masses: A Feasibility study. Can Assoc Radiol J 2023; 74:723-736. [PMID: 36882380 DOI: 10.1177/08465371231160052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/09/2023] Open
Abstract
Purpose: To evaluate the feasibility and usefulness of T1 and T2 mapping in characterization of mediastinal masses. Methods: From August 2019 through December 2021, 47 patients underwent 3.0-T chest MRI with T1 and post-contrast T1 mapping using modified look-locker inversion recovery sequences and T2 mapping using a T2-prepared single-shot shot steady-state free precession technique. Mean native T1, native T2, and post-contrast T1 values were measured by drawing the region of interest in the mediastinal masses, and enhancement index (EI) was calculated using these values. Results: All mapping images were acquired successfully, without significant artifact. There were 25 thymic epithelial tumors (TETs), 3 schwannomas, 6 lymphomas, and 9 thymic cysts, and 4 other cystic tumors. TET, schwannoma, and lymphoma were grouped together as "solid tumor," to be compared with thymic cysts and other tumors ("cystic tumors"). The mean post-contrast T1 mapping (P < .001), native T2 mapping (P < .001), and EI (P < .001) values showed significant difference between these two groups. Among TETs, high risk TETs (thymoma types B2, B3, and thymic carcinoma) showed significantly higher native T2 mapping values (P = .002) than low risk TETs (thymoma types A, B1, and AB). For all measured variables, interrater reliability was good to excellent (intraclass coefficient [ICC]: .869∼.990) and intrarater reliability was excellent (ICC: .911∼.995). Conclusion: The use of T1 and T2 mapping in MRI of mediastinal masses is feasible and may provide additional information in the evaluation of mediastinal masses.
Collapse
Affiliation(s)
- Kyongmin S Beck
- Department of Radiology, Catholic University of Korea, Banpo-daero, Seoul, Republic of Korea
| | - Suyon Chang
- Department of Radiology, Catholic University of Korea, Banpo-daero, Seoul, Republic of Korea
| | - Kwanyong Hyun
- Department of Thoracic and Cardiovascular Surgery, Catholic University of Korea, Banpo-daero, Seoul, Republic of Korea
| | - Yeoun Eun Sung
- Department of Hospital Pathology, Catholic University of Korea, Seoul, Republic of Korea
| | - Kyo-Young Lee
- Department of Hospital Pathology, Catholic University of Korea, Seoul, Republic of Korea
- Department of Pathology, Konkuk University Chungju Hospital, Konkuk University School of Medicine, Chungju, Republic of Korea
| | - Jung Im Jung
- Department of Radiology, Catholic University of Korea, Banpo-daero, Seoul, Republic of Korea
| |
Collapse
|
25
|
Qin Y, Liu J, Zhang X, Fan X, Li G, Chang Y, Li L. To explore the pathogenesis of Bell's palsy using diffusion tensor image. Sci Rep 2023; 13:15298. [PMID: 37714930 PMCID: PMC10504306 DOI: 10.1038/s41598-023-42570-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 09/12/2023] [Indexed: 09/17/2023] Open
Abstract
To explore the pathogenesis of Bell's palsy using the diffusion tensor image on 3.0 T MR. The healthy people and the patients with Bell's palsy underwent intraparotid facial nerve scanning by using the DTI and T1 structural sequence at 3.0 T MR. The raw DTI data were performed affine transformation and nonlinear registration in the common MNI152_T1 space and resampled to the 0.4 mm3 voxel size. A group of 4 spherical seed regions were placed on the intratemporal facial nerves in the common space, bilaterally and symmetrically. The DTI data in the common space were used to track the intratemporal facial nerve fibers by using TrackVis and its Diffusion Toolkit. Each tractography was used to construct the maximum probability map (MPM) according to the majority rule. The fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD) and radial diffusivity (RD) were calculated and extracted on the basis of MPM. For healthy people, there was no significant difference in FA, MD, RD and AD of bilateral facial nerves. For patients with Bell's palsy, there was no significant difference in AD, there was significant difference in FA, MD and RD between the affected nerve and the healthy nerve (P < 0.02). This study showed that the myelin sheath injury of the intratemporal facial nerve is the main cause of Bell's palsy. Most neural axons are not damaged. The results may explain the pathogenesis of the Bell's palsy, which is self-limited for most cases.
Collapse
Affiliation(s)
- Yi Qin
- Radiology Department, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, No. 88, ChangLing Road, XiQing District, Tianjin, 300381, China
- National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, No. 88, ChangLing Road, XiQing District, Tianjin, 300381, China
| | - Jihua Liu
- Radiology Department, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, No. 88, ChangLing Road, XiQing District, Tianjin, 300381, China.
- National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, No. 88, ChangLing Road, XiQing District, Tianjin, 300381, China.
| | - Xuening Zhang
- Radiology Department, The Second Hospital of Tianjin Medical University, No. 23, Pingjiang Road, He Xi District, Tianjin, 300211, China
| | - Xiaonong Fan
- National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, No. 88, ChangLing Road, XiQing District, Tianjin, 300381, China
| | - Guiping Li
- National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, No. 88, ChangLing Road, XiQing District, Tianjin, 300381, China
| | - Yinghui Chang
- National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, No. 88, ChangLing Road, XiQing District, Tianjin, 300381, China
| | - Li Li
- National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, No. 88, ChangLing Road, XiQing District, Tianjin, 300381, China
| |
Collapse
|
26
|
Chen H, Dai K, Bao J, Zhong S, Hu C, Liu Y, Zhang Z. Pseudo multishot echo-planar imaging for geometric distortion improvement. NMR IN BIOMEDICINE 2023; 36:e4885. [PMID: 36454107 DOI: 10.1002/nbm.4885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 11/21/2022] [Accepted: 11/24/2022] [Indexed: 06/17/2023]
Abstract
Conventional echo-planar imaging (EPI) uses a radiofrequency pulse for excitation and a prolonged echo train to sample k space, while off-resonance and T2 * decay effects caused by magnetic susceptibility variation accumulate within each echo, leading to geometric distortion. Multishot EPI methods, which divide k space into segments, can shorten the effective echo spacing and reduce the distortion on EPI images. But multiple shots cost longer scan time and render susceptibility to motion. In this study, we propose a new "multishot" EPI method termed pseudo multishot EPI (pmsEPI), in which phase-encoding lines are segmented as in multishot EPI but are collected within a single shot. With the magnetization divided into different pathways via interleaved excitation instead of refocusing in a single long echo train, the total phase error accumulation is reduced in each segmented acquisition, thereby improving distortion of the resultant EPI image. The performance of the pmsEPI method is demonstrated by phantom and in vivo brain experiments on a 3-T scanner. The experimental results show that the distortion displacements of pmsEPI acquisition compared with conventional EPI decrease by 50% with two pseudo shots and 66% with three pseudo shots, validating the ability of the method to obtain images with reduced distortion in a single shot, although magnetization splitting may induce more than 40% SNR loss and minor artifacts. Specifically, the ability of pmsEPI in diffusion-weighted imaging with different trajectory options is highlighted, and the flexibility is demonstrated in a single-shot blip up and down acquisition.
Collapse
Affiliation(s)
- Hao Chen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China
| | - Ke Dai
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Jianfeng Bao
- Functional Magnetic Resonance and Molecular Imaging Key Laboratory of Henan Province, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Sijie Zhong
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Chenxi Hu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yiling Liu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Zhiyong Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
27
|
Ota T, Tsuboyama T, Onishi H, Nakamoto A, Fukui H, Yano K, Honda T, Kiso K, Tatsumi M, Tomiyama N. Diagnostic accuracy of MRI for evaluating myometrial invasion in endometrial cancer: a comparison of MUSE-DWI, rFOV-DWI, and DCE-MRI. LA RADIOLOGIA MEDICA 2023:10.1007/s11547-023-01635-4. [PMID: 37120661 DOI: 10.1007/s11547-023-01635-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 04/20/2023] [Indexed: 05/01/2023]
Abstract
OBJECTIVES To compare the image quality of high-resolution diffusion-weighted imaging (DWI) using multiplexed sensitivity encoding (MUSE) versus reduced field-of-view (rFOV) techniques in endometrial cancer (EC) and to compare the diagnostic performance of these techniques with that of dynamic contrast-enhanced (DCE) MRI for assessing myometrial invasion of EC. METHODS MUSE-DWI and rFOV-DWI were obtained preoperatively in 58 women with EC. Three radiologists assessed the image quality of MUSE-DWI and rFOV-DWI. For 55 women who underwent DCE-MRI, the same radiologists assessed the superficial and deep myometrial invasion using MUSE-DWI, rFOV-DWI, and DCE-MRI. Qualitative scores were compared using the Wilcoxon signed-rank test. Receiver operating characteristic analysis was performed to compare the diagnostic performance. RESULTS Artifacts, sharpness, lesion conspicuity, and overall quality were significantly better with MUSE-DWI than with rFOV-DWI (p < 0.05). The area under the curve (AUC) of MUSE-DWI, rFOV-DWI, and DCE-MRI for the assessment of myometrial invasion were not significantly different except for significantly higher AUC of MUSE-DWI than that of DCE-MRI for superficial myometrial invasion (0.76 for MUSE-DWI and 0.64 for DCE-MRI, p = 0.049) and for deep myometrial invasion (0.92 for MUSE-DWI and 0.80 for DCE-MRI, p = 0.022) in one observer, and that of rFOV-DWI for deep myometrial invasion in another observer (0.96 for MUSE-DWI and 0.89 for rFOV-MRI, p = 0.048). CONCLUSION MUSE-DWI exhibits better image quality than rFOV-DWI. MUSE-DWI and rFOV-DWI shows almost equivalent diagnostic performance compared to DCE-MRI for assessing superficial and deep myometrial invasion in EC although MUSE-DWI may be helpful for some radiologists.
Collapse
Affiliation(s)
- Takashi Ota
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
| | - Takahiro Tsuboyama
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Hiromitsu Onishi
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Atsushi Nakamoto
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Hideyuki Fukui
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Keigo Yano
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Toru Honda
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Kengo Kiso
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Mitsuaki Tatsumi
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Noriyuki Tomiyama
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| |
Collapse
|
28
|
Bao Q, Xie W, Otikovs M, Xia L, Xie H, Liu X, Liu K, Zhang Z, Chen F, Zhou X, Liu C. Unsupervised cycle-consistent network using restricted subspace field map for removing susceptibility artifacts in EPI. Magn Reson Med 2023; 90:458-472. [PMID: 37052369 DOI: 10.1002/mrm.29653] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 02/19/2023] [Accepted: 03/14/2023] [Indexed: 04/14/2023]
Abstract
PURPOSE To design an unsupervised deep neural model for correcting susceptibility artifacts in single-shot Echo Planar Imaging (EPI) and evaluate the model for preclinical and clinical applications. METHODS This work proposes an unsupervised cycle-consistent model based on the restricted subspace field map to take advantage of both the deep learning (DL) and the reverse polarity-gradient (RPG) method for single-shot EPI. The proposed model consists of three main components: (1) DLRPG neural network (DLRPG-net) to obtain field maps based on a pair of images acquired with reversed phase encoding; (2) spin physical model-based modules to obtain the corrected undistorted images based on the learned field map; and (3) cycle-consistency loss between the input images and back-calculated images from each cycle is explored for network training. In addition, the field maps generated by DLRPG-net belong to a restricted subspace, which is a span of predefined cubic splines to ensure the smoothness of the field maps and avoid blurring in the corrected images. This new method is trained and validated on both preclinical and clinical datasets for diffusion MRI. RESULTS The proposed network could effectively generate smooth field maps and correct susceptibility artifacts in single-shot EPI. Simulated and in vivo preclinical/clinical experiments demonstrated that our method outperforms the state-of-the-art susceptibility artifact correction methods. Furthermore, the ablation experiments of the cycle-consistent network and the restricted subspace in generating field maps did show the advantages of DLRPG-net. CONCLUSION The proposed method (DLRPG-net) can effectively correct susceptibility artifacts for preclinical and clinical single-shot EPI sequences.
Collapse
Affiliation(s)
- Qingjia Bao
- Key Laboratory of Magnetic Resonance in Biological Systems, Innovation Academy for Precision Measurement Science and Technology, Wuhan, 430071, People's Republic of China
| | - Weida Xie
- School of Information Engineering, Wuhan University of Technology, Wuhan, People's Republic of China
| | | | - Liyang Xia
- School of Information Engineering, Wuhan University of Technology, Wuhan, People's Republic of China
| | - Han Xie
- Key Laboratory of Magnetic Resonance in Biological Systems, Innovation Academy for Precision Measurement Science and Technology, Wuhan, 430071, People's Republic of China
| | - Xinjie Liu
- Key Laboratory of Magnetic Resonance in Biological Systems, Innovation Academy for Precision Measurement Science and Technology, Wuhan, 430071, People's Republic of China
| | - Kewen Liu
- School of Information Engineering, Wuhan University of Technology, Wuhan, People's Republic of China
| | - Zhi Zhang
- Key Laboratory of Magnetic Resonance in Biological Systems, Innovation Academy for Precision Measurement Science and Technology, Wuhan, 430071, People's Republic of China
| | - Fang Chen
- Key Laboratory of Magnetic Resonance in Biological Systems, Innovation Academy for Precision Measurement Science and Technology, Wuhan, 430071, People's Republic of China
| | - Xin Zhou
- Key Laboratory of Magnetic Resonance in Biological Systems, Innovation Academy for Precision Measurement Science and Technology, Wuhan, 430071, People's Republic of China
- University of Chinese Academy of Sciences, Beijing, 100049, People's Republic of China
- Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology-Optics Valley Laboratory, Hubei, 430074, People's Republic of China
| | - Chaoyang Liu
- Key Laboratory of Magnetic Resonance in Biological Systems, Innovation Academy for Precision Measurement Science and Technology, Wuhan, 430071, People's Republic of China
- University of Chinese Academy of Sciences, Beijing, 100049, People's Republic of China
- Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology-Optics Valley Laboratory, Hubei, 430074, People's Republic of China
| |
Collapse
|
29
|
Yang T, Li Y, Ye Z, Yao S, Li Q, Yuan Y, Song B. Diffusion Weighted Imaging of the Abdomen and Pelvis: Recent Technical Advances and Clinical Applications. Acad Radiol 2023; 30:470-482. [PMID: 36038417 DOI: 10.1016/j.acra.2022.07.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 07/20/2022] [Accepted: 07/23/2022] [Indexed: 01/25/2023]
Abstract
Diffusion weighted imaging (DWI) serves as one of the most important functional magnetic resonance imaging techniques in abdominal and pelvic imaging. It is designed to reflect the diffusion of water molecules and is particularly sensitive to the malignancies. Yet, the limitations of image distortion and artifacts in single-shot DWI may hamper its widespread use in clinical practice. With recent technical advances in DWI, such as simultaneous multi-slice excitation, computed or reduced field-of-view techniques, as well as advanced shimming methods, it is possible to achieve shorter acquisition time, better image quality, and higher robustness in abdominopelvic DWI. This review discussed the recent advances of each DWI approach, and highlighted its future perspectives in abdominal and pelvic imaging, hoping to familiarize physicians and radiologists with the technical improvements in this field and provide future research directions.
Collapse
Affiliation(s)
- Ting Yang
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Ying Li
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Zheng Ye
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Shan Yao
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Qing Li
- MR Collaborations, Siemens Healthcare, Shanghai, China
| | - Yuan Yuan
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Bin Song
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China; Department of Radiology, Sanya People's Hospital, Sanya, Hainan, China.
| |
Collapse
|
30
|
Lyu J, Li Y, Yan F, Chen W, Wang C, Li R. Multi-channel GAN-based calibration-free diffusion-weighted liver imaging with simultaneous coil sensitivity estimation and reconstruction. Front Oncol 2023; 13:1095637. [PMID: 36845688 PMCID: PMC9945270 DOI: 10.3389/fonc.2023.1095637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 01/09/2023] [Indexed: 02/10/2023] Open
Abstract
Introduction Diffusion-weighted imaging (DWI) with parallel reconstruction may suffer from a mismatch between the coil calibration scan and imaging scan due to motions, especially for abdominal imaging. Methods This study aimed to construct an iterative multichannel generative adversarial network (iMCGAN)-based framework for simultaneous sensitivity map estimation and calibration-free image reconstruction. The study included 106 healthy volunteers and 10 patients with tumors. Results The performance of iMCGAN was evaluated in healthy participants and patients and compared with the SAKE, ALOHA-net, and DeepcomplexMRI reconstructions. The peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), root mean squared error (RMSE), and histograms of apparent diffusion coefficient (ADC) maps were calculated for assessing image qualities. The proposed iMCGAN outperformed the other methods in terms of the PSNR (iMCGAN: 41.82 ± 2.14; SAKE: 17.38 ± 1.78; ALOHA-net: 20.43 ± 2.11 and DeepcomplexMRI: 39.78 ± 2.78) for b = 800 DWI with an acceleration factor of 4. Besides, the ghosting artifacts in the SENSE due to the mismatch between the DW image and the sensitivity maps were avoided using the iMCGAN model. Discussion The current model iteratively refined the sensitivity maps and the reconstructed images without additional acquisitions. Thus, the quality of the reconstructed image was improved, and the aliasing artifact was alleviated when motions occurred during the imaging procedure.
Collapse
Affiliation(s)
- Jun Lyu
- School of Computer and Control Engineering, Yantai University, Yantai, Shandong, China
| | - Yan Li
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China,College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Fuhua Yan
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China,College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Weibo Chen
- Philips Healthcare (China), Shanghai, China
| | - Chengyan Wang
- Human Phenome Institute, Fudan University, Shanghai, China,*Correspondence: Chengyan Wang, ; Ruokun Li,
| | - Ruokun Li
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China,College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai, China,*Correspondence: Chengyan Wang, ; Ruokun Li,
| |
Collapse
|
31
|
El Homsi M, Bates DDB, Mazaheri Y, Sosa R, Gangai N, Petkovska I. Multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE) in diffusion-weighted imaging for rectal MRI: a quantitative and qualitative analysis at multiple b-values. Abdom Radiol (NY) 2023; 48:448-457. [PMID: 36307596 PMCID: PMC9905276 DOI: 10.1007/s00261-022-03710-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 10/07/2022] [Accepted: 10/10/2022] [Indexed: 01/19/2023]
Abstract
PURPOSE To compare four diffusion-weighted imaging (DWI) sequences for image quality, rectal contour, and lesion conspicuity, and to assess the difference in their signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC). METHODS In this retrospective study of 36 consecutive patients who underwent 3.0 T rectal MRI from January-June 2020, DWI was performed with single-shot echo planar imaging (ss-EPI) (b800 s/mm2), multiplexed sensitivity encoding (MUSE) (b800 s/mm2), MUSE (b1500 s/mm2), and field-of-view optimized and constrained undistorted single-shot (FOCUS) (b1500 s/mm2). Two radiologists independently scored image quality using a 5-point Likert scale. Inter-reader agreement was assessed using the weighted Cohen's к. SNR, CNR, and ADC measurements were compared using the paired t-test. RESULTS For both readers, MUSE b800 scored significantly higher for image quality, rectal contour, and lesion conspicuity compared to ss-EPI; MUSE b800 also scored significantly higher for image quality and rectal contour compared to all other sequences. Lesion conspicuity was equally superior for MUSE b800 and MUSE b1500 compared to the other two sequences. There was good to excellent inter-reader agreement for all qualitative features (к = 0.72-0.88). MUSE b800 had the highest SNR; MUSE b1500 had the highest CNR. A significant difference in ADC was observed between ss-EPI compared to the other sequences (p < 0.001) and between MUSE b800 and FOCUS. No significant difference in ADC was found between MUSE b1500 and FOCUS b1500. CONCLUSION MUSE b800 improved image quality over ss-EPI and both MUSE b800 and b1500 showed better tumor conspicuity compared to conventional ss-EPI.
Collapse
Affiliation(s)
- Maria El Homsi
- Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - David D B Bates
- Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Yousef Mazaheri
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Ramon Sosa
- Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Natalie Gangai
- Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Iva Petkovska
- Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.
| |
Collapse
|
32
|
Liu P, Fall S, Ahiatsi M, Balédent O. Real-time phase contrast MRI versus conventional phase contrast MRI at different spatial resolutions and velocity encodings. Clin Imaging 2023; 94:93-102. [PMID: 36502617 DOI: 10.1016/j.clinimag.2022.11.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 11/09/2022] [Accepted: 11/28/2022] [Indexed: 12/04/2022]
Abstract
PURPOSES To compare the accuracy of real-time phase-contrast echo-planar MRI (EPI-PC) and conventional cine phase-contrast MRI (Conv-PC) and to assess the influence of spatial resolutions (pixel size) and velocity encoding on flow measurements obtained with the two sequences. METHODS Flow quantification was assessed using a pulsatile flow phantom (diameter: 9.5 mm; mean flow rate: 1150 mm3/s; mean flow velocity: 1.6 cm/s). Firstly, the accuracy of the EPI-PC was checked by comparing it with the flow rate in the calibrated phantom and the pulsation index from Conv-PC. Secondly, flow data from the two sequences were compared quantitatively as a function of the pixel size and the velocity encoding. RESULTS The mean percentage difference between the EPI-PC flow rate and calibrated phantom flow rate was -2.9 ± 2.1% (Mean ± SD). The pulsatility indices for EPI-PC and Conv-PC were respectively 0.64 and 0.59. In order to keep the flow rate measurement error within 10%, the ROI in Conv-PC had to contain at least 13 pixels, while the ROI in EPI-PC had to contain at least 9 pixels. Furthermore, Conv-PC had a higher velocity-to-noise ratio and could use a higher velocity encoding than EPI-PC (20 cm/s and 15 cm/s, respectively). CONCLUSIONS The result of this in vitro study confirmed the accuracy of EPI-PC, and found that EPI-PC can adapt to lower spatial resolutions, but is more sensitive to velocity encoding than Conv-PC.
Collapse
Affiliation(s)
- Pan Liu
- CHIMERE UR 7516, Jules Verne University of Picardy, Amiens, France; Medical Image Processing Department, Amiens Picardy University Hospital, Amiens, France.
| | - Sidy Fall
- MRI Department, Jules Verne University of Picardy, Amiens, France
| | - Maureen Ahiatsi
- CHIMERE UR 7516, Jules Verne University of Picardy, Amiens, France
| | - Olivier Balédent
- CHIMERE UR 7516, Jules Verne University of Picardy, Amiens, France; Medical Image Processing Department, Amiens Picardy University Hospital, Amiens, France; MRI Department, Jules Verne University of Picardy, Amiens, France.
| |
Collapse
|
33
|
Chen H, Dai K, Zhong S, Zheng J, Zhang X, Yang S, Cao T, Wang C, Karasan E, Frydman L, Zhang Z. High-resolution multi-shot diffusion-weighted MRI combining markerless prospective motion correction and locally low-rank constrained reconstruction. Magn Reson Med 2023; 89:605-619. [PMID: 36198013 DOI: 10.1002/mrm.29468] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 08/10/2022] [Accepted: 09/04/2022] [Indexed: 12/13/2022]
Abstract
PURPOSE Subject head motion is a major challenge in DWI, leading to image blurring, signal losses, and biases in the estimated diffusion parameters. Here, we investigate a combined application of prospective motion correction and spatial-angular locally low-rank constrained reconstruction to obtain robust, multi-shot, high-resolution diffusion-weighted MRI under substantial motion. METHODS Single-shot EPI with retrospective motion correction can mitigate motion artifacts and resolve any mismatching of gradient encoding orientations; however, it is limited by low spatial resolution and image distortions. Multi-shot acquisition strategies could achieve higher resolution and image fidelity but increase the vulnerability to motion artifacts and phase variations related to cardiac pulsations from shot to shot. We use prospective motion correction with optical markerless motion tracking to remove artifacts and reduce image blurring due to bulk motion, combined with locally low-rank regularization to correct for remaining artifacts due to shot-to-shot phase variations. RESULTS The approach was evaluated on healthy adult volunteers at 3 Tesla under different motion patterns. In multi-shot DWI, image blurring due to motion with 20 mm translations and 30° rotations was successfully removed by prospective motion correction, and aliasing artifacts caused by shot-to-shot phase variations were addressed by locally low-rank regularization. The ability of prospective motion correction to preserve the orientational information in DTI without requiring a reorientation of the b-matrix is highlighted. CONCLUSION The described technique is proved to hold valuable potential for mapping brain diffusivity and connectivity at high resolution for studies in subjects/cohorts where motion is common, including neonates, pediatrics, and patients with neurological disorders.
Collapse
Affiliation(s)
- Hao Chen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Ke Dai
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Sijie Zhong
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Jiaxu Zheng
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China.,United Imaging Healthcare, Shanghai, People's Republic of China
| | - Xinyue Zhang
- United Imaging Healthcare, Shanghai, People's Republic of China
| | - Shasha Yang
- United Imaging Healthcare, Shanghai, People's Republic of China
| | - Tuoyu Cao
- United Imaging Healthcare, Shanghai, People's Republic of China
| | - Chaohong Wang
- United Imaging Healthcare, Shanghai, People's Republic of China
| | - Ekin Karasan
- Department of Electrical Engineering and Computer Sciences, University of California Berkeley, Berkeley, California
| | - Lucio Frydman
- Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot, Israel
| | - Zhiyong Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| |
Collapse
|
34
|
Morelli L, Palombo M, Buizza G, Riva G, Pella A, Fontana G, Imparato S, Iannalfi A, Orlandi E, Paganelli C, Baroni G. Microstructural parameters from DW-MRI for tumour characterization and local recurrence prediction in particle therapy of skull-base chordoma. Med Phys 2023; 50:2900-2913. [PMID: 36602230 DOI: 10.1002/mp.16202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 11/21/2022] [Accepted: 12/15/2022] [Indexed: 01/06/2023] Open
Abstract
BACKGROUND Quantitative imaging such as Diffusion-Weighted MRI (DW-MRI) can be exploited to non-invasively derive patient-specific tumor microstructure information for tumor characterization and local recurrence risk prediction in radiotherapy. PURPOSE To characterize tumor microstructure according to proliferative capacity and predict local recurrence through microstructural markers derived from pre-treatment conventional DW-MRI, in skull-base chordoma (SBC) patients treated with proton (PT) and carbon ion (CIRT) radiotherapy. METHODS Forty-eight patients affected by SBC, who underwent conventional DW-MRI before treatment and were enrolled for CIRT (n = 25) or PT (n = 23), were retrospectively selected. Clinically verified local recurrence information (LR) and histological information (Ki-67, proliferation index) were collected. Apparent diffusion coefficient (ADC) maps were calculated from pre-treatment DW-MRI and, from these, a set of microstructural parameters (cellular radius R, volume fraction vf, diffusion D) were derived by applying a fine-tuning procedure to a framework employing Monte Carlo simulations on synthetic cell substrates. In addition, apparent cellularity (ρapp ) was estimated from vf and R for an easier clinical interpretation. Histogram-based metrics (mean, median, variance, entropy) from estimated parameters were considered to investigate differences (Mann-Whitney U-test, α = 0.05) in estimated tumor microstructure in SBCs characterized by low or high cell proliferation (Ki-67). Recurrence-free survival analyses were also performed to assess the ability of the microstructural parameters to stratify patients according to the risk of local recurrence (Kaplan-Meier curves, log-rank test α = 0.05). RESULTS Refined microstructural markers revealed optimal capabilities in discriminating patients according to cell proliferation, achieving best results with mean values (p-values were 0.0383, 0.0284, 0.0284, 0.0468, and 0.0088 for ADC, R, vf, D, and ρapp, respectively). Recurrence-free survival analyses showed significant differences between populations at high and low risk of local recurrence as stratified by entropy values of estimated microstructural parameters (p = 0.0110). CONCLUSION Patient-specific microstructural information was non-invasively derived providing potentially useful tools for SBC treatment personalization and optimization in particle therapy.
Collapse
Affiliation(s)
- Letizia Morelli
- Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milan, Italy
| | - Marco Palombo
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, UK
- School of Computer Science and Informatics, Cardiff University, Cardiff, UK
| | - Giulia Buizza
- Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milan, Italy
| | - Giulia Riva
- National Center of Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Andrea Pella
- National Center of Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Giulia Fontana
- National Center of Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Sara Imparato
- National Center of Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Alberto Iannalfi
- National Center of Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Ester Orlandi
- National Center of Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Chiara Paganelli
- Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milan, Italy
| | - Guido Baroni
- Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milan, Italy
- National Center of Oncological Hadrontherapy (CNAO), Pavia, Italy
| |
Collapse
|
35
|
Visualization of human optic nerve by diffusion tensor mapping and degree of neuropathy. PLoS One 2022; 17:e0278987. [PMID: 36508429 PMCID: PMC9744320 DOI: 10.1371/journal.pone.0278987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 11/28/2022] [Indexed: 12/14/2022] Open
Abstract
Diffusion-weighted magnetic resonance imaging of the human optic nerve and tract is technically difficult because of its small size, the inherent strong signal generated by the surrounding fat and the cerebrospinal fluid, and due to eddy current-induced distortions and subject movement artifacts. The effects of the bone canal through which the optic nerve passes, and the proximity of blood vessels, muscles and tendons are generally unknown. Also, the limited technical capabilities of the scanners and the minimization of acquisition times result in poor quality diffusion-weighted images. It is challenging for current tractography methods to accurately track optic pathway fibers that correspond to known anatomy. Despite these technical limitations and low image resolution, here we show how to visualize the optic nerve and tract and quantify nerve atrophy. Our visualization method based on the analysis of the diffusion tensor shows marked differences between a healthy male subject and a male subject with progressive optic nerve neuropathy. These differences coincide with diffusion scalar metrics and are not visible on standard morphological images. A quantification of the degree of optic nerve atrophy in a systematic way is provided and it is tested on 9 subjects from the Human Connectome Project.
Collapse
|
36
|
Ji Lee E, Chang YW, Kon Sung J, Thomas B. Feasibility of deep learning k-space-to-image reconstruction for diffusion weighted imaging in patients with breast cancers: focus on image quality and reduced scan time. Eur J Radiol 2022; 157:110608. [DOI: 10.1016/j.ejrad.2022.110608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 10/29/2022] [Accepted: 11/08/2022] [Indexed: 11/14/2022]
|
37
|
Tamada T, Kido A, Ueda Y, Takeuchi M, Kanki A, Neelavalli J, Yamamoto A. Comparison of single-shot EPI and multi-shot EPI in prostate DWI at 3.0 T. Sci Rep 2022; 12:16070. [PMID: 36168032 PMCID: PMC9515065 DOI: 10.1038/s41598-022-20518-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 09/14/2022] [Indexed: 12/02/2022] Open
Abstract
In prostate MRI, single-shot EPI (ssEPI) DWI still suffers from distortion and blurring. Multi-shot EPI (msEPI) overcomes the drawbacks of ssEPI DWI. The aim of this article was to compare the image quality and diagnostic performance for clinically significant prostate cancer (csPC) between ssEPI DWI and msEPI DWI. This retrospective study included 134 patients with suspected PC who underwent 3.0 T MRI and subsequent MRI-guided biopsy. Three radiologists independently assessed anatomical distortion, prostate edge clarity, and lesion conspicuity score for pathologically confirmed csPC. Lesion apparent diffusion coefficient (ADC) and benign ADC were also calculated. In 17 PC patients who underwent prostatectomy, three radiologists independently assessed eight prostate regions by DWI score in PI-RADS v 2.1. Anatomical distortion and prostate edge clarity were significantly higher in msEPI DWI than in ssEPI DWI in the three readers. Lesion conspicuity score was significantly higher in msEPI DWI than in ssEPI DWI in reader 1 and reader 3. Regarding discrimination ability between PC with GS ≤ 3 + 4 and PC with GS ≥ 4 + 3 using lesion ADC, AUC was comparable between ssEPI DWI and msEPI DWI. For diagnostic performance of csPC using DWI score, AUC was comparable between msEPI DWI and ssEPI DWI in all readers. Compared with ssEPI DWI, msEPI DWI had improved image quality and similar or higher diagnostic performance.
Collapse
Affiliation(s)
- Tsutomu Tamada
- Department of Radiology, Kawasaki Medical School, 577 Matsushima, Kurashiki, Okayama, 701-0192, Japan.
| | - Ayumu Kido
- Department of Radiology, Kawasaki Medical School, 577 Matsushima, Kurashiki, Okayama, 701-0192, Japan
| | | | | | - Akihiko Kanki
- Department of Radiology, Kawasaki Medical School, 577 Matsushima, Kurashiki, Okayama, 701-0192, Japan
| | | | - Akira Yamamoto
- Department of Radiology, Kawasaki Medical School, 577 Matsushima, Kurashiki, Okayama, 701-0192, Japan
| |
Collapse
|
38
|
Syed Nasser N, Rajan S, Venugopal VK, Lasič S, Mahajan V, Mahajan H. A review on investigation of the basic contrast mechanism underlying multidimensional diffusion MRI in assessment of neurological disorders. J Clin Neurosci 2022; 102:26-35. [PMID: 35696817 DOI: 10.1016/j.jocn.2022.05.027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 05/20/2022] [Accepted: 05/30/2022] [Indexed: 12/26/2022]
Abstract
INTRODUCTION Multidimensional diffusion MRI (MDD MRI) is a novel diffusion technique that uses advanced gradient waveforms for microstructural tissue characterization to provide information about average rate, anisotropy and orientation of the diffusion and to disentangle the signal fraction from specific cell types i.e., elongated cells, isotropic cells and free water. AIM To review the diagnostic potential of MDD MRI in the clinical setting for microstructural tissue characterization in patients with neurological disorders to aid in patient care and treatment. METHOD A scoping review on the clinical applications of MDD MRI was conducted from original articles published in PubMed and Scopus from 2015 to 2021 using the keywords "Multidimensional diffusion MRI" OR "diffusion tensor distribution" OR "Tensor-Valued Diffusion" OR "b-tensor encoding" OR "microscopic diffusion anisotropy" OR "microscopic anisotropy" OR "microscopic fractional anisotropy" OR "double diffusion encoding" OR "triple diffusion encoding" OR "double pulsed field gradients" OR "double wave vector" OR "correlation tensor imaging" AND "brain" OR "axons". RESULTS Initially 145 articles were screened and after applying inclusion and exclusion criteria, nine articles were included in the final analysis. In most of these studies, microscopic diffusion anisotropy within the lesion showed deviation from the normal-appearing tissue. CONCLUSION Multidimensional diffusion MRI can provide better quantification and visualization of tissue microstructure than conventional diffusion MRI and can be used in the clinical setting for diagnosis of neurological disorders.
Collapse
Affiliation(s)
| | - Sriram Rajan
- Department of Radiology, Mahajan Imaging, New Delhi, India
| | | | | | | | - Harsh Mahajan
- CARPL.ai, New Delhi, India; Department of Radiology, Mahajan Imaging, New Delhi, India
| |
Collapse
|
39
|
Use of real-time phase-contrast MRI to quantify the effect of spontaneous breathing on the cerebral arteries. Neuroimage 2022; 258:119361. [PMID: 35688317 DOI: 10.1016/j.neuroimage.2022.119361] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 05/05/2022] [Accepted: 06/06/2022] [Indexed: 11/22/2022] Open
Abstract
Quantification of the effect of breathing on the cerebral circulation provides a better mechanistic understanding of the brain's circulatory system and is important in the early diagnosis of certain neurological diseases. However, conventional cine phase-contrast (CINE-PC) MRI cannot be used in this field of study because it only provides an average cardiac cycle flow curve reconstructed from multiple cardiac cycles. Unlike CINE-PC, phase-contrast echo-planar imaging (EPI-PC) can be used to quantify the blood flow rate in "real-time" and thus assess the effect of breathing on blood flow. Here, we first used post-processing software (developed in-house) to determine the feasibility of quantifying cerebral arterial blood flow with EPI-PC (relative to CINE-PC) in 16 participants. In a second step, we developed a new time-domain method for quantifying the intensity and the phase shift of the effects of breathing on the mean flow rate, stroke volume, cardiac period and amplitude of cerebral blood flow (in 10 participants). Our results showed that EPI-PC can quantify cerebral arterial blood flow rate with much the same degree of accuracy as CINE-PC but is more strongly influenced by differences in magnetic susceptibility. We found that breathing affected the mean flow rate, stroke volume and cardiac period of cerebral arterial blood flow.
Collapse
|
40
|
Radhakrishnan H, Shabestari SK, Blurton-Jones M, Obenaus A, Stark CEL. Using Advanced Diffusion-Weighted Imaging to Predict Cell Counts in Gray Matter: Potential and Pitfalls. Front Neurosci 2022; 16:881713. [PMID: 35720733 PMCID: PMC9204138 DOI: 10.3389/fnins.2022.881713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 05/18/2022] [Indexed: 11/22/2022] Open
Abstract
Recent advances in diffusion imaging have given it the potential to non-invasively detect explicit neurobiological properties, beyond what was previously possible with conventional structural imaging. However, there is very little known about what cytoarchitectural properties these metrics, especially those derived from newer multi-shell models like Neurite Orientation Dispersion and Density Imaging (NODDI) correspond to. While these diffusion metrics do not promise any inherent cell type specificity, different brain cells have varying morphologies, which could influence the diffusion signal in distinct ways. This relationship is currently not well-characterized. Understanding the possible cytoarchitectural signatures of diffusion measures could allow them to estimate important neurobiological properties like cell counts, potentially resulting in a powerful clinical diagnostic tool. Here, using advanced diffusion imaging (NODDI) in the mouse brain, we demonstrate that different regions have unique relationships between cell counts and diffusion metrics. We take advantage of this exclusivity to introduce a framework to predict cell counts of different types of cells from the diffusion metrics alone, in a region-specific manner. We also outline the challenges of reliably developing such a model and discuss the precautions the field must take when trying to tie together medical imaging modalities and histology.
Collapse
Affiliation(s)
- Hamsanandini Radhakrishnan
- Mathematical, Computational and Systems Biology, University of California, Irvine, Irvine, CA, United States
| | - Sepideh Kiani Shabestari
- Department of Neurobiology and Behavior, School of Biological Sciences, University of California, Irvine, Irvine, CA, United States
| | - Mathew Blurton-Jones
- Department of Neurobiology and Behavior, School of Biological Sciences, University of California, Irvine, Irvine, CA, United States
| | - Andre Obenaus
- Department of Pediatrics, School of Medicine, University of California, Irvine, Irvine, CA, United States
| | - Craig E. L. Stark
- Mathematical, Computational and Systems Biology, University of California, Irvine, Irvine, CA, United States
- Department of Neurobiology and Behavior, School of Biological Sciences, University of California, Irvine, Irvine, CA, United States
| |
Collapse
|
41
|
Breutigam NJ, Günther M, Hoinkiss DC, Eickel K, Frost R, Buck MA, Porter DA. Combined acquisition of diffusion and T 2*-weighted measurements using simultaneous multi-contrast magnetic resonance imaging. MAGMA (NEW YORK, N.Y.) 2022; 35:421-440. [PMID: 34855052 PMCID: PMC9188537 DOI: 10.1007/s10334-021-00976-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 11/08/2021] [Accepted: 11/09/2021] [Indexed: 12/14/2022]
Abstract
Object In this work, we present a technique called simultaneous multi-contrast imaging (SMC) to acquire multiple contrasts within a single measurement. Simultaneous multi-slice imaging (SMS) shortens scan time by allowing the repetition time (TR) to be reduced for a given number of slices. SMC imaging preserves TR, while combining different scan types into a single acquisition. This technique offers new opportunities in clinical protocols where examination time is a critical factor and multiple image contrasts must be acquired. Materials and methods High-resolution, navigator-corrected, diffusion-weighted imaging was performed simultaneously with T2*-weighted acquisition at 3 T in a phantom and in five healthy subjects using an adapted readout-segmented EPI sequence (rs-EPI). Results The results demonstrated that simultaneous acquisition of two contrasts (here diffusion-weighted imaging and T2*-weighting) with SMC imaging is feasible with robust separation of contrasts and minimal effect on image quality. Discussion The simultaneous acquisition of multiple contrasts reduces the overall examination time and there is an inherent registration between contrasts. By using the results of this study to control saturation effects in SMC, the method enables rapid acquisition of distortion-matched and well-registered diffusion-weighted and T2*-weighted imaging, which could support rapid diagnosis and treatment of acute stroke. Supplementary Information The online version contains supplementary material available at 10.1007/s10334-021-00976-3.
Collapse
Affiliation(s)
- Nora-Josefin Breutigam
- Imaging Physics, Fraunhofer Institute for Digital Medicine MEVIS, Max-von-Laue-Str. 2, 28359, Bremen, Germany.
| | - Matthias Günther
- Imaging Physics, Fraunhofer Institute for Digital Medicine MEVIS, Max-von-Laue-Str. 2, 28359, Bremen, Germany.,Mediri GmbH, Heidelberg, DE, Germany.,University of Bremen, Bremen, DE, Germany
| | - Daniel Christopher Hoinkiss
- Imaging Physics, Fraunhofer Institute for Digital Medicine MEVIS, Max-von-Laue-Str. 2, 28359, Bremen, Germany
| | - Klaus Eickel
- Imaging Physics, Fraunhofer Institute for Digital Medicine MEVIS, Max-von-Laue-Str. 2, 28359, Bremen, Germany.,University of Bremen, Bremen, DE, Germany
| | - Robert Frost
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA.,Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Mareike Alicja Buck
- Imaging Physics, Fraunhofer Institute for Digital Medicine MEVIS, Max-von-Laue-Str. 2, 28359, Bremen, Germany.,University of Bremen, Bremen, DE, Germany
| | - David A Porter
- Imaging Centre of Excellence (ICE), University of Glasgow, Glasgow, Scotland
| |
Collapse
|
42
|
Resolution and b value dependent Structural Connectome in ex vivo Mouse Brain. Neuroimage 2022; 255:119199. [PMID: 35417754 PMCID: PMC9195912 DOI: 10.1016/j.neuroimage.2022.119199] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Revised: 04/05/2022] [Accepted: 04/07/2022] [Indexed: 12/24/2022] Open
Abstract
Diffusion magnetic resonance imaging has been widely used in both clinical and preclinical studies to characterize tissue microstructure and structural connectivity. The diffusion MRI protocol for the Human Connectome Project (HCP) has been developed and optimized to obtain high-quality, high-resolution diffusion MRI (dMRI) datasets. However, such efforts have not been fully explored in preclinical studies, especially for rodents. In this study, high quality dMRI datasets of mouse brains were acquired at 9.4T system from two vendors. In particular, we acquired a high-spatial resolution dMRI dataset (25 μm isotropic with 126 diffusion encoding directions), which we believe to be the highest spatial resolution yet obtained; and a high-angular resolution dMRI dataset (50 μm isotropic with 384 diffusion encoding directions), which we believe to be the highest angular resolution compared to the dMRI datasets at the microscopic resolution. We systematically investigated the effects of three important parameters that affect the final outcome of the connectome: b value (1000s/mm2 to 8000 s/mm2), angular resolution (10 to 126), and spatial resolution (25 μm to 200 μm). The stability of tractography and connectome increase with the angular resolution, where more than 50 angles is necessary to achieve consistent results. The connectome and quantitative parameters derived from graph theory exhibit a linear relationship to the b value (R2 > 0.99); a single-shell acquisition with b value of 3000 s/mm2 shows comparable results to the multi-shell high angular resolution dataset. The dice coefficient decreases and both false positive rate and false negative rate gradually increase with coarser spatial resolution. Our study provides guidelines and foundations for exploration of tradeoffs among acquisition parameters for the structural connectome in ex vivo mouse brain.
Collapse
|
43
|
Zhang F, Daducci A, He Y, Schiavi S, Seguin C, Smith RE, Yeh CH, Zhao T, O'Donnell LJ. Quantitative mapping of the brain's structural connectivity using diffusion MRI tractography: A review. Neuroimage 2022; 249:118870. [PMID: 34979249 PMCID: PMC9257891 DOI: 10.1016/j.neuroimage.2021.118870] [Citation(s) in RCA: 94] [Impact Index Per Article: 47.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 12/03/2021] [Accepted: 12/31/2021] [Indexed: 12/13/2022] Open
Abstract
Diffusion magnetic resonance imaging (dMRI) tractography is an advanced imaging technique that enables in vivo reconstruction of the brain's white matter connections at macro scale. It provides an important tool for quantitative mapping of the brain's structural connectivity using measures of connectivity or tissue microstructure. Over the last two decades, the study of brain connectivity using dMRI tractography has played a prominent role in the neuroimaging research landscape. In this paper, we provide a high-level overview of how tractography is used to enable quantitative analysis of the brain's structural connectivity in health and disease. We focus on two types of quantitative analyses of tractography, including: 1) tract-specific analysis that refers to research that is typically hypothesis-driven and studies particular anatomical fiber tracts, and 2) connectome-based analysis that refers to research that is more data-driven and generally studies the structural connectivity of the entire brain. We first provide a review of methodology involved in three main processing steps that are common across most approaches for quantitative analysis of tractography, including methods for tractography correction, segmentation and quantification. For each step, we aim to describe methodological choices, their popularity, and potential pros and cons. We then review studies that have used quantitative tractography approaches to study the brain's white matter, focusing on applications in neurodevelopment, aging, neurological disorders, mental disorders, and neurosurgery. We conclude that, while there have been considerable advancements in methodological technologies and breadth of applications, there nevertheless remains no consensus about the "best" methodology in quantitative analysis of tractography, and researchers should remain cautious when interpreting results in research and clinical applications.
Collapse
Affiliation(s)
- Fan Zhang
- Brigham and Women's Hospital, Harvard Medical School, Boston, USA.
| | | | - Yong He
- State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Beijing, China; Beijing Key Laboratory of Brain Imaging and Connectomics, Beijing Normal University, Beijing, China; IDG/McGovern Institute for Brain Research, Beijing Normal University, Beijing, China; Chinese Institute for Brain Research, Beijing, China
| | - Simona Schiavi
- Department of Computer Science, University of Verona, Verona, Italy
| | - Caio Seguin
- Melbourne Neuropsychiatry Centre, University of Melbourne and Melbourne Health, Melbourne, Australia; The University of Sydney, School of Biomedical Engineering, Sydney, Australia
| | - Robert E Smith
- The Florey Institute of Neuroscience and Mental Health, Melbourne, Australia; Florey Department of Neuroscience and Mental Health, The University of Melbourne, Melbourne, Australia
| | - Chun-Hung Yeh
- Institute for Radiological Research, Chang Gung University, Taoyuan, Taiwan; Department of Psychiatry, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
| | - Tengda Zhao
- State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Beijing, China; Beijing Key Laboratory of Brain Imaging and Connectomics, Beijing Normal University, Beijing, China; IDG/McGovern Institute for Brain Research, Beijing Normal University, Beijing, China
| | | |
Collapse
|
44
|
Johansson J, Lagerstrand K, Ivarsson L, Svensson PA, Hebelka H, Maier SE. Brain diffusion MRI with multiplexed sensitivity encoding for reduced distortion in a pediatric patient population. Magn Reson Imaging 2022; 87:97-103. [PMID: 34999160 DOI: 10.1016/j.mri.2022.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 12/30/2021] [Accepted: 01/04/2022] [Indexed: 10/19/2022]
Abstract
BACKGROUND Diffusion-weighted imaging (DWI) is a valuable tool for routine imaging of the pediatric brain. However, the commonly used single-shot (ss) echo-planar imaging (EPI) DWI sequence is prone to geometric distortions and T2*-blurring. This study aimed to investigate in a pediatric population the benefits of using multiplexed sensitivity-encoding (MUSE) without and with reversed polarity gradients (RPG) instead. METHODS This retrospective study compared image quality, geometric distortions, and diffusion values between three different approaches for DWI (ssEPI, MUSE, and RPG-MUSE) in 14 patients (median age = 4 (0.6-15) years, 11 males). Distortion levels were quantified and compared in two brain regions, i.e., the brain stem and the temporal lobes, using the Dice Coefficient and the Hausdorff Distance, with T2-weighted images as reference. Expected geometrical distortion was further evaluated by comparing the effective echo spacing between the DWI sequences. Apparent diffusion coefficient (ADC) values were determined in the genu of the corpus callosum and the optic nerves. Two raters graded overall image quality and image distortions on a Likert scale. RESULTS Distortion levels assessed with Dice coefficient and Hausdorff distance were significantly lower for MUSE (p < 0.05) and RPG-MUSE (p < 0.01) compared to ssEPI. No significant difference in ADC values was observed between methods. The RPG-MUSE method was graded by one rater as significantly higher in overall image quality than ssEPI (p < 0.05) and by both raters as significantly lower in levels of image distortions than both MUSE (p < 0.05) and ssEPI (p < 0.05). These results were in agreement with the reduced effective echo spacing was that was attained with MUSE and RPG-MUSE. CONCLUSION For imaging of the pediatric brain, MUSE and even more so RPG-MUSE offers both improved geometric fidelity and image quality compared to ssEPI.
Collapse
Affiliation(s)
- Jens Johansson
- Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| | - Kerstin Lagerstrand
- Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Liz Ivarsson
- Department of Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Pär-Arne Svensson
- Department of Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Hanna Hebelka
- Department of Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden; Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Stephan E Maier
- Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
45
|
Nanosized T1 MRI Contrast Agent Based on a Polyamidoamine as Multidentate Gd Ligand. Molecules 2021; 27:molecules27010174. [PMID: 35011405 PMCID: PMC8746954 DOI: 10.3390/molecules27010174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 12/15/2021] [Accepted: 12/23/2021] [Indexed: 11/17/2022] Open
Abstract
A linear polyamidoamine (PAA) named BAC-EDDS, containing metal chelating repeat units composed of two tert-amines and four carboxylic groups, has been prepared by the aza-Michael polyaddition of ethylendiaminodisuccinic (EDDS) with 2,2-bis(acrylamido)acetic acid (BAC). It was characterized by size exclusion chromatography (SEC), FTIR, UV–Vis and NMR spectroscopies. The pKa values of the ionizable groups of the repeat unit were estimated by potentiometric titration, using a purposely synthesized molecular ligand (Agly-EDDS) mimicking the structure of the BAC-EDDS repeat unit. Dynamic light scattering (DLS) and ζ-potential analyses revealed the propensity of BAC-EDDS to form stable nanoaggregates with a diameter of approximately 150 nm at pH 5 and a net negative charge at physiological pH, in line with an isoelectric point <2. BAC-EDDS stably chelated Gd (III) ions with a molar ratio of 0.5:1 Gd (III)/repeat unit. The stability constant of the molecular model Gd-Agly-EDDS (log K = 17.43) was determined as well, by simulating the potentiometric titration through the use of Hyperquad software. In order to comprehend the efficiency of Gd-BAC-EDDS in contrasting magnetic resonance images, the nuclear longitudinal (r1) and transverse (r2) relaxivities as a function of the externally applied static magnetic field were investigated and compared to the ones of commercial contrast agents. Furthermore, a model derived from the Solomon–Bloembergen–Morgan theory for the field dependence of the NMR relaxivity curves was applied and allowed us to evaluate the rotational correlation time of the complex (τ = 0.66 ns). This relatively high value is due to the dimensions of Gd-BAC-EDDS, and the associated rotational motion causes a peak in the longitudinal relaxivity at ca. 75 MHz, which is close to the frequencies used in clinics. The good performances of Gd-BAC-EDDS as a contrast agent were also confirmed through in vitro magnetic resonance imaging experiments with a 0.2 T magnetic field.
Collapse
|
46
|
van der Hoogt KJJ, Schipper RJ, Winter-Warnars GA, Ter Beek LC, Loo CE, Mann RM, Beets-Tan RGH. Factors affecting the value of diffusion-weighted imaging for identifying breast cancer patients with pathological complete response on neoadjuvant systemic therapy: a systematic review. Insights Imaging 2021; 12:187. [PMID: 34921645 PMCID: PMC8684570 DOI: 10.1186/s13244-021-01123-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 11/06/2021] [Indexed: 12/18/2022] Open
Abstract
This review aims to identify factors causing heterogeneity in breast DWI-MRI and their impact on its value for identifying breast cancer patients with pathological complete response (pCR) on neoadjuvant systemic therapy (NST). A search was performed on PubMed until April 2020 for studies analyzing DWI for identifying breast cancer patients with pCR on NST. Technical and clinical study aspects were extracted and assessed for variability. Twenty studies representing 1455 patients/lesions were included. The studies differed with respect to study population, treatment type, DWI acquisition technique, post-processing (e.g., mono-exponential/intravoxel incoherent motion/stretched exponential modeling), and timing of follow-up studies. For the acquisition and generation of ADC-maps, various b-value combinations were used. Approaches for drawing regions of interest on longitudinal MRIs were highly variable. Biological variability due to various molecular subtypes was usually not taken into account. Moreover, definitions of pCR varied. The individual areas under the curve for the studies range from 0.50 to 0.92. However, overlapping ranges of mean/median ADC-values at pre- and/or during and/or post-NST were found for the pCR and non-pCR groups between studies. The technical, clinical, and epidemiological heterogeneity may be causal for the observed variability in the ability of DWI to predict pCR accurately. This makes implementation of DWI for pCR prediction and evaluation based on one absolute ADC threshold for all breast cancer types undesirable. Multidisciplinary consensus and appropriate clinical study design, taking biological and therapeutic variation into account, is required for obtaining standardized, reliable, and reproducible DWI measurements for pCR/non-pCR identification.
Collapse
Affiliation(s)
- Kay J J van der Hoogt
- Department of Radiology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands. .,GROW School of Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht, The Netherlands.
| | - Robert J Schipper
- Department of Radiology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands
| | - Gonneke A Winter-Warnars
- Department of Radiology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands
| | - Leon C Ter Beek
- Department of Medical Physics, The Netherlands Cancer Institute - Antoni van Leeuwenhoek, Amsterdam, The Netherlands
| | - Claudette E Loo
- Department of Radiology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands
| | - Ritse M Mann
- Department of Radiology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands.,Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Regina G H Beets-Tan
- Department of Radiology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands.,GROW School of Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht, The Netherlands.,Danish Colorectal Cancer Unit South, Institute of Regional Health Research, Vejle University Hospital, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
47
|
Yeh FC, Irimia A, Bastos DCDA, Golby AJ. Tractography methods and findings in brain tumors and traumatic brain injury. Neuroimage 2021; 245:118651. [PMID: 34673247 PMCID: PMC8859988 DOI: 10.1016/j.neuroimage.2021.118651] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 10/05/2021] [Accepted: 10/11/2021] [Indexed: 12/31/2022] Open
Abstract
White matter fiber tracking using diffusion magnetic resonance imaging (dMRI) provides a noninvasive approach to map brain connections, but improving anatomical accuracy has been a significant challenge since the birth of tractography methods. Utilizing tractography in brain studies therefore requires understanding of its technical limitations to avoid shortcomings and pitfalls. This review explores tractography limitations and how different white matter pathways pose different challenges to fiber tracking methodologies. We summarize the pros and cons of commonly-used methods, aiming to inform how tractography and its related analysis may lead to questionable results. Extending these experiences, we review the clinical utilization of tractography in patients with brain tumors and traumatic brain injury, starting from tensor-based tractography to more advanced methods. We discuss current limitations and highlight novel approaches in the context of these two conditions to inform future tractography developments.
Collapse
Affiliation(s)
- Fang-Cheng Yeh
- Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
| | - Andrei Irimia
- Ethel Percy Andrus Gerontology Center, Leonard Davis School of Gerontology, University of Southern California, Los Angeles, California, USA; Corwin D. Denney Research Center, Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA
| | | | - Alexandra J Golby
- Department of Neurosurgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA; Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
48
|
Platt T, Ladd ME, Paech D. 7 Tesla and Beyond: Advanced Methods and Clinical Applications in Magnetic Resonance Imaging. Invest Radiol 2021; 56:705-725. [PMID: 34510098 PMCID: PMC8505159 DOI: 10.1097/rli.0000000000000820] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 08/07/2021] [Accepted: 08/07/2021] [Indexed: 12/15/2022]
Abstract
ABSTRACT Ultrahigh magnetic fields offer significantly higher signal-to-noise ratio, and several magnetic resonance applications additionally benefit from a higher contrast-to-noise ratio, with static magnetic field strengths of B0 ≥ 7 T currently being referred to as ultrahigh fields (UHFs). The advantages of UHF can be used to resolve structures more precisely or to visualize physiological/pathophysiological effects that would be difficult or even impossible to detect at lower field strengths. However, with these advantages also come challenges, such as inhomogeneities applying standard radiofrequency excitation techniques, higher energy deposition in the human body, and enhanced B0 field inhomogeneities. The advantages but also the challenges of UHF as well as promising advanced methodological developments and clinical applications that particularly benefit from UHF are discussed in this review article.
Collapse
Affiliation(s)
- Tanja Platt
- From the Medical Physics in Radiology, German Cancer Research Center (DKFZ)
| | - Mark E. Ladd
- From the Medical Physics in Radiology, German Cancer Research Center (DKFZ)
- Faculty of Physics and Astronomy
- Faculty of Medicine, University of Heidelberg, Heidelberg
- Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen
| | - Daniel Paech
- Division of Radiology, German Cancer Research Center (DKFZ), Heidelberg
- Clinic for Neuroradiology, University of Bonn, Bonn, Germany
| |
Collapse
|
49
|
Pietsch M, Christiaens D, Hajnal JV, Tournier JD. dStripe: Slice artefact correction in diffusion MRI via constrained neural network. Med Image Anal 2021; 74:102255. [PMID: 34634644 PMCID: PMC8566280 DOI: 10.1016/j.media.2021.102255] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 09/22/2021] [Accepted: 09/24/2021] [Indexed: 11/25/2022]
Abstract
dStripe allows removing inter-slice intensity artefacts in the presence of motion. It is not tied to a particular q-space sampling scheme or motion correction method. Can be trained in the absence of ground truth data. Uses explicit constraints that locally preserve in-plane image contrast.
MRI scanner and sequence imperfections and advances in reconstruction and imaging techniques to increase motion robustness can lead to inter-slice intensity variations in Echo Planar Imaging. Leveraging deep convolutional neural networks as universal image filters, we present a data-driven method for the correction of acquisition artefacts that manifest as inter-slice inconsistencies, regardless of their origin. This technique can be applied to motion- and dropout-artefacted data by embedding it in a reconstruction pipeline. The network is trained in the absence of ground-truth data on, and finally applied to, the reconstructed multi-shell high angular resolution diffusion imaging signal to produce a corrective slice intensity modulation field. This correction can be performed in either motion-corrected or scattered source-space. We focus on gaining control over the learned filter and the image data consistency via built-in spatial frequency and intensity constraints. The end product is a corrected image reconstructed from the original raw data, modulated by a multiplicative field that can be inspected and verified to match the expected features of the artefact. In-plane, the correction approximately preserves the contrast of the diffusion signal and throughout the image series, it reduces inter-slice inconsistencies within and across subjects without biasing the data. We apply our pipeline to enhance the super-resolution reconstruction of neonatal multi-shell high angular resolution data as acquired in the developing Human Connectome Project.
Collapse
Affiliation(s)
- Maximilian Pietsch
- Centre for Medical Engineering, King's College London, London, UK; Centre for the Developing Brain, King's College London, London, UK; Department of Forensic & Neurodevelopmental Sciences, King's College London, London, UK.
| | - Daan Christiaens
- Centre for the Developing Brain, King's College London, London, UK; Department of Electrical Engineering, ESAT/PSI, KU Leuven, Leuven, Belgium
| | - Joseph V Hajnal
- Centre for Medical Engineering, King's College London, London, UK; Centre for the Developing Brain, King's College London, London, UK
| | - J-Donald Tournier
- Centre for Medical Engineering, King's College London, London, UK; Centre for the Developing Brain, King's College London, London, UK
| |
Collapse
|
50
|
Mani M, Magnotta VA, Jacob M. qModeL: A plug-and-play model-based reconstruction for highly accelerated multi-shot diffusion MRI using learned priors. Magn Reson Med 2021; 86:835-851. [PMID: 33759240 PMCID: PMC8076086 DOI: 10.1002/mrm.28756] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Revised: 02/08/2021] [Accepted: 02/09/2021] [Indexed: 01/19/2023]
Abstract
PURPOSE To introduce a joint reconstruction method for highly undersampled multi-shot diffusion weighted (msDW) scans. METHODS Multi-shot EPI methods enable higher spatial resolution for diffusion MRI, but at the expense of long scan-time. Highly accelerated msDW scans are needed to enable their utilization in advanced microstructure studies, which require high q-space coverage. Previously, joint k-q undersampling methods coupled with compressed sensing were shown to enable very high acceleration factors. However, the reconstruction of this data using sparsity priors is challenging and is not suited for multi-shell data. We propose a new reconstruction that recovers images from the combined k-q data jointly. The proposed qModeL reconstruction brings together the advantages of model-based iterative reconstruction and machine learning, extending the idea of plug-and-play algorithms. Specifically, qModeL works by prelearning the signal manifold corresponding to the diffusion measurement space using deep learning. The prelearned manifold prior is incorporated into a model-based reconstruction to provide a voxel-wise regularization along the q-dimension during the joint recovery. Notably, the learning does not require in vivo training data and is derived exclusively from biophysical modeling. Additionally, a plug-and-play total variation denoising provides regularization along the spatial dimension. The proposed framework is tested on k-q undersampled single-shell and multi-shell msDW acquisition at various acceleration factors. RESULTS The qModeL joint reconstruction is shown to recover DWIs from 8-fold accelerated msDW acquisitions with error less than 5% for both single-shell and multi-shell data. Advanced microstructural analysis performed using the undersampled reconstruction also report reasonable accuracy. CONCLUSION qModeL enables the joint recovery of highly accelerated multi-shot dMRI utilizing learning-based priors. The bio-physically driven approach enables the use of accelerated multi-shot imaging for multi-shell sampling and advanced microstructure studies.
Collapse
Affiliation(s)
- Merry Mani
- Department of Radiology, University of Iowa, Iowa City, Iowa
| | | | - Mathews Jacob
- Department of Electrical and Computer Engineering, University of Iowa, Iowa City, Iowa
| |
Collapse
|