1
|
Zhou K, Yu Y, Xu L, Wang S, Li Z, Liu Y, Kwok RTK, Sun J, Lam JWY, He G, Zhao Z, Tang BZ. Aggregation-Induced Emission Luminogen Based Wearable Visible-Light Penetrator for Deep Photodynamic Therapy. ACS NANO 2024; 18:29930-29941. [PMID: 39423317 DOI: 10.1021/acsnano.4c10452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/21/2024]
Abstract
Photodynamic therapy (PDT) has emerged as a preferred nonsurgical treatment in clinical applications due to its capacity to selectively eradicate diseased tissues while minimizing damage to normal tissue. Nevertheless, its clinical efficacy is constrained by the limited penetration of visible light. Although near-infrared (NIR) lasers offer enhanced tissue penetration, the dearth of suitable photosensitizers and a pronounced imaging-treatment disparity pose challenges. Additionally, clinical implementation via optical fiber implantation carries infection risks and necessitates minimally invasive surgery, contradicting PDT's noninvasive advantage. In this study, we introduce a brilliant approach utilizing aggregation-induced emission luminogens (AIEgen) to develop a visible-light penetrator (VLP), coupled with wireless light emitting diodes (LEDs), enabling deep photodynamic therapy. We validate the therapeutic efficacy of this visible-light penetrator in tissues inaccessible to conventional PDT, demonstrating significant suppression of inflammatory diffusion in vivo using AIEgen TBPPM loaded within the VLP, which exhibits a transmittance of 86% in tissues with a thickness of 3 mm. This innovative visible-light penetrator effectively overcomes the substantial limitations of PDT in clinical settings and holds promise for advancing phototherapy.
Collapse
Affiliation(s)
- Kun Zhou
- School of Science and Engineering, Clinical Translational Research Center of Aggregation-Induced Emission, The Second Affiliated Hospital, School of Medicine, Shenzhen Institute of Aggregate Science and Technology, The Chinese University of Hong Kong, Shenzhen (CUHK-Shenzhen), Shenzhen, Guangdong 518172, China
- Department of Chemistry, The Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Division of Life Science, State Key Laboratory of Molecular Neuroscience, and Department of Biological and Chemical Engineering The Hong Kong University of Science and Technology, Kowloon, Hong Kong 999077, China
| | - Ying Yu
- Hohai University (Changzhou Campus), Changzhou, Jiangsu 213200, China
| | - Letian Xu
- State Key Laboratory of Luminescent Materials and Devices, Guangdong Provincial Key Laboratory of Luminescence from Molecular Aggregates, South China University of Technology, 510640 Guangzhou, China
| | - Siyuan Wang
- School of Science and Engineering, Clinical Translational Research Center of Aggregation-Induced Emission, The Second Affiliated Hospital, School of Medicine, Shenzhen Institute of Aggregate Science and Technology, The Chinese University of Hong Kong, Shenzhen (CUHK-Shenzhen), Shenzhen, Guangdong 518172, China
| | - Zhuojian Li
- School of Science and Engineering, Clinical Translational Research Center of Aggregation-Induced Emission, The Second Affiliated Hospital, School of Medicine, Shenzhen Institute of Aggregate Science and Technology, The Chinese University of Hong Kong, Shenzhen (CUHK-Shenzhen), Shenzhen, Guangdong 518172, China
| | - Yong Liu
- AIE Institute, Guangzhou Development District, Huangpu, Guangzhou, Guangdong 510530, China
| | - Ryan T K Kwok
- Department of Chemistry, The Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Division of Life Science, State Key Laboratory of Molecular Neuroscience, and Department of Biological and Chemical Engineering The Hong Kong University of Science and Technology, Kowloon, Hong Kong 999077, China
| | - Jianwei Sun
- Department of Chemistry, The Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Division of Life Science, State Key Laboratory of Molecular Neuroscience, and Department of Biological and Chemical Engineering The Hong Kong University of Science and Technology, Kowloon, Hong Kong 999077, China
| | - Jacky W Y Lam
- Department of Chemistry, The Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Division of Life Science, State Key Laboratory of Molecular Neuroscience, and Department of Biological and Chemical Engineering The Hong Kong University of Science and Technology, Kowloon, Hong Kong 999077, China
| | - Gang He
- Frontier Institute of Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi 710054, China
| | - Zheng Zhao
- School of Science and Engineering, Clinical Translational Research Center of Aggregation-Induced Emission, The Second Affiliated Hospital, School of Medicine, Shenzhen Institute of Aggregate Science and Technology, The Chinese University of Hong Kong, Shenzhen (CUHK-Shenzhen), Shenzhen, Guangdong 518172, China
| | - Ben Zhong Tang
- School of Science and Engineering, Clinical Translational Research Center of Aggregation-Induced Emission, The Second Affiliated Hospital, School of Medicine, Shenzhen Institute of Aggregate Science and Technology, The Chinese University of Hong Kong, Shenzhen (CUHK-Shenzhen), Shenzhen, Guangdong 518172, China
- Department of Chemistry, The Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Division of Life Science, State Key Laboratory of Molecular Neuroscience, and Department of Biological and Chemical Engineering The Hong Kong University of Science and Technology, Kowloon, Hong Kong 999077, China
- AIE Institute, Guangzhou Development District, Huangpu, Guangzhou, Guangdong 510530, China
| |
Collapse
|
2
|
Xue Z, Chou W, Xu Y, Cheng Z, Ren X, Sun T, Tong W, Xie Y, Chen J, Zhang N, Sheng X, Wang Y, Zhao H, Yang J, Ding H. Battery-free optoelectronic patch for photodynamic and light therapies in treating bacteria-infected wounds. Biosens Bioelectron 2024; 261:116467. [PMID: 38901392 DOI: 10.1016/j.bios.2024.116467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 05/15/2024] [Accepted: 06/03/2024] [Indexed: 06/22/2024]
Abstract
Light therapy is an effective approach for the treatment of a variety of challenging dermatological conditions. In contrast to existing methods involving high doses and large areas of illumination, alternative strategies based on wearable designs that utilize a low light dose over an extended period provide a precise and convenient treatment. In this study, we present a battery-free, skin-integrated optoelectronic patch that incorporates a coil-powered circuit, an array of microscale violet and red light emitting diodes (LEDs), and polymer microneedles (MNs) loaded with 5-aminolevulinic acid (5-ALA). These polymer MNs, based on the biodegradable composite materials of polyvinyl alcohol (PVA) and hyaluronic acid (HA), serve as light waveguides for optical access and a medium for drug release into deeper skin layers. Unlike conventional clinical photomedical appliances with a rigid and fixed light source, this flexible design allows for a conformable light source that can be applied directly to the skin. In animal models with bacterial-infected wounds, the experimental group with the combination treatment of metronomic photodynamic and light therapies reduced 2.48 log10 CFU mL-1 in bactericidal level compared to the control group, indicating an effective anti-infective response. Furthermore, post-treatment analysis revealed the activation of proregenerative genes in monocyte and macrophage cell populations, suggesting enhanced tissue regeneration, neovascularization, and dermal recovery. Overall, this optoelectronic patch design broadens the scope for targeting deep skin lesions, and provides an alternative with the functionality of standard clinical light therapy methods.
Collapse
Affiliation(s)
- Zhao Xue
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China
| | - Wenxin Chou
- School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Yixuan Xu
- Department of Laser Medicine, the First Medical Centre, Chinese PLA General Hospital, Medical School of Chinese PLA, Beijing, 100853, China
| | - Ziyi Cheng
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China
| | - Xuechun Ren
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China
| | - Tianzhen Sun
- School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Wenbin Tong
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China
| | - Yang Xie
- Department of Electronic Engineering, Beijing National Research Center for Information Science and Technology, Institute for Precision Medicine, Center for Flexible Electronics Technology, IDG/McGovern Institute for Brain Research, Tsinghua University, Beijing, 100084, China
| | - Junyu Chen
- Department of Electronic Engineering, Beijing National Research Center for Information Science and Technology, Institute for Precision Medicine, Center for Flexible Electronics Technology, IDG/McGovern Institute for Brain Research, Tsinghua University, Beijing, 100084, China
| | - Nuohan Zhang
- GMA Optoelectronic Technology Limited, Xinyang 464000, China
| | - Xing Sheng
- Department of Electronic Engineering, Beijing National Research Center for Information Science and Technology, Institute for Precision Medicine, Center for Flexible Electronics Technology, IDG/McGovern Institute for Brain Research, Tsinghua University, Beijing, 100084, China
| | - Yongtian Wang
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China
| | - Hongyou Zhao
- School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China.
| | - Jian Yang
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China.
| | - He Ding
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China.
| |
Collapse
|
3
|
Nowak J, Kaczmarek MK. Deep Indentation Tests of Soft Materials Using Mobile and Stationary Devices. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4233. [PMID: 39274622 PMCID: PMC11395885 DOI: 10.3390/ma17174233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2024] [Revised: 08/20/2024] [Accepted: 08/23/2024] [Indexed: 09/16/2024]
Abstract
Measurements of the properties of soft materials are important from the point of view of medical diagnostics of soft tissues as well as testing the quality of food products and many technical materials. One of the frequently used techniques for testing such materials, attractive due to its non-invasive nature, is the indentation technique, which does not puncture the material. The difficulty of testing soft materials, which affects the objectivity of the results, is related to the problems of stable positioning of the studied material in relation to the indentation apparatus, especially with a device held by the operator. This work concerns the comparison of test results using an indentation apparatus mounted on mobile and stationary handles. The tested materials are cylindrical samples of polyurethane foams with three different stiffnesses and the same samples with a 0.5 or 1 mm thick silicone layer. The study presented uses an apparatus with a flat cylindrical indenter, with a surface area of 1 cm2, pressed to a depth of 10 mm (so-called deep tests). Based on the recorded force changes over time, five descriptors of the indentation test were determined and compared for both types of handles. The tests performed showed that the elastic properties of foam materials alone and with a silicone layer can be effectively characterized by the maximum forces during recessing and retraction and the slopes of the recessing and retraction curves. In the case of two-layer materials, these descriptors reflect both the characteristics of the foams and the silicone layer. The results show that the above property of the deep indentation method distinguishes it from the shallow indentation method. The repeatability of the tests performed in the mobile and stationary holders were determined to be comparable.
Collapse
Affiliation(s)
- Joanna Nowak
- Faculty of Mechatronics, Kazimierz Wielki University, 85-074 Bydgoszcz, Poland
| | - Mariusz K Kaczmarek
- Faculty of Mechatronics, Kazimierz Wielki University, 85-074 Bydgoszcz, Poland
| |
Collapse
|
4
|
Liu Z, Li S, Anantha P, Thanakornsombut T, Wu L, Chen J, Tsuchiya R, Tripathi AK, Chen Y, Barman I. Plasmodium sporozoite shows distinct motility patterns in responses to three-dimensional environments. iScience 2024; 27:110463. [PMID: 39129829 PMCID: PMC11315120 DOI: 10.1016/j.isci.2024.110463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 11/20/2023] [Accepted: 07/02/2024] [Indexed: 08/13/2024] Open
Abstract
During malaria infection, Plasmodium sporozoites, the fast-moving stage of the parasite, are injected by a mosquito into the skin of the mammalian host. In the skin, sporozoites need to migrate through the dermal tissue to enter the blood vessel. Sporozoite motility is critical for infection but not well understood. Here, we used collagen hydrogels with tunable fiber structures, as an in vitro model for the skin. After injecting sporozoites into the hydrogel, we analyzed their motility in three-dimension (3D). We found that sporozoites demonstrated chiral motility, in that they mostly follow right-handed helical trajectories. In high-concentration collagen gel, sporozoites have lower instantaneous speed, but exhibit straighter tracks compared to low-concentration collagen gel, which leads to longer net displacement and faster dissemination. Taken together, our study indicates an inner mechanism for sporozoites to adapt to the environment, which could help with their successful exit from the skin tissue.
Collapse
Affiliation(s)
- Zhenhui Liu
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Songman Li
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Pooja Anantha
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | | | - Lintong Wu
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Junjie Chen
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, USA
- Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, MD, USA
- Center for Cell Dynamics, Johns Hopkins University, Baltimore, MD, USA
| | - Ryohma Tsuchiya
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, USA
- Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, MD, USA
- Center for Cell Dynamics, Johns Hopkins University, Baltimore, MD, USA
| | - Abhai K. Tripathi
- Department of Molecular Microbiology & Immunology, Johns Hopkins University, Baltimore, MD, USA
| | - Yun Chen
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, USA
- Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, MD, USA
- Center for Cell Dynamics, Johns Hopkins University, Baltimore, MD, USA
| | - Ishan Barman
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, USA
| |
Collapse
|
5
|
Almashakbeh Y, Shamimi H, Callejas A, Rus G. Using torsional wave elastography to evaluate spring pot parameters in skin tumor mimicking phantoms. Sci Rep 2024; 14:16058. [PMID: 38992074 PMCID: PMC11239839 DOI: 10.1038/s41598-024-66621-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Accepted: 07/02/2024] [Indexed: 07/13/2024] Open
Abstract
Estimating the tissue parameters of skin tumors is crucial for diagnosis and effective therapy in dermatology and related fields. However, identifying the most sensitive biomarkers require an optimal rheological model for simulating skin behavior this remains an ongoing research endeavor. Additionally, the multi-layered structure of the skin introduces further complexity to this task. In order to surmount these challenges, an inverse problem methodology, in conjunction with signal analysis techniques, is being employed. In this study, a fractional rheological model is presented to enhance the precision of skin tissue parameter estimation from the acquired signal from torsional wave elastography technique (TWE) on skin tumor-mimicking phantoms for lab validation and the estimation of the thickness of the cancerous layer. An exhaustive analysis of the spring-pot model (SP) solved by the finite difference time domain (FDTD) is conducted. The results of experiments performed using a TWE probe designed and prototyped in the laboratory were validated against ultrafast imaging carried out by the Verasonics Research System. Twelve tissue-mimicking phantoms, which precisely simulated the characteristics of skin tissue, were prepared for our experimental setting. The experimental data from these bi-layer phantoms were measured using a TWE probe, and the parameters of the skin tissue were estimated using inverse problem-solving. The agreement between the two datasets was evaluated by comparing the experimental data obtained from the TWE technique with simulated data from the SP- FDTD model using Pearson correlation, dynamic time warping (DTW), and time-frequency representation. Our findings show that the SP-FDTD model and TWE are capable of determining the mechanical properties of both layers in a bilayer phantom, using a single signal and an inverse problem approach. The ultrafast imaging and the validation of TWE results further demonstrate the robustness and reliability of our technology for a realistic range of phantoms. This fusion of the SP-FDTD model and TWE, as well as inverse problem-solving methods has the potential to have a considerable impact on diagnoses and treatments in dermatology and related fields.
Collapse
Affiliation(s)
- Yousef Almashakbeh
- Department of Allied Engineering Sciences, Facility of Engineering, The Hashemite University, Zarqa, 13133, Jordan.
| | - Hirad Shamimi
- Department of Structural Mechanics, University of Granada, Granada, 18071, Spain
- Instituto de Investigación Biosanitaria, ibs.GRANADA, Granada, 18012, Spain
| | - Antonio Callejas
- Department of Structural Mechanics, University of Granada, Granada, 18071, Spain
- Instituto de Investigación Biosanitaria, ibs.GRANADA, Granada, 18012, Spain
- Excellence Research Unit, "Modelling Nature" (MNat), Granada, 18071, Spain
| | - Guillermo Rus
- Department of Structural Mechanics, University of Granada, Granada, 18071, Spain
- Instituto de Investigación Biosanitaria, ibs.GRANADA, Granada, 18012, Spain
- Excellence Research Unit, "Modelling Nature" (MNat), Granada, 18071, Spain
| |
Collapse
|
6
|
Sharma M, Brown AW, Powell NM, Rajaram N, Tong L, Mourani PM, Schootman M. Racial and skin color mediated disparities in pulse oximetry in infants and young children. Paediatr Respir Rev 2024; 50:62-72. [PMID: 38233229 PMCID: PMC11139570 DOI: 10.1016/j.prrv.2023.12.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Revised: 12/18/2023] [Accepted: 12/19/2023] [Indexed: 01/19/2024]
Abstract
Race-based and skin pigmentation-related inaccuracies in pulse oximetry have recently been highlighted in several large electronic health record-based retrospective cohort studies across diverse patient populations and healthcare settings. Overestimation of oxygen saturation by pulse oximeters, particularly in hypoxic states, is disparately higher in Black compared to other racial groups. Compared to adult literature, pediatric studies are relatively few and mostly reliant on birth certificates or maternal race-based classification of comparison groups. Neonates, infants, and young children are particularly susceptible to the adverse life-long consequences of hypoxia and hyperoxia. Successful neonatal resuscitation, precise monitoring of preterm and term neonates with predominantly lung pathology, screening for congenital heart defects, and critical decisions on home oxygen, ventilator support and medication therapies, are only a few examples of situations that are highly reliant on the accuracy of pulse oximetry. Undetected hypoxia, especially if systematically different in certain racial groups may delay appropriate therapies and may further perpetuate health care disparities. The role of biological factors that may differ between racial groups, particularly skin pigmentation that may contribute to biased pulse oximeter readings needs further evaluation. Developmental and maturational changes in skin physiology and pigmentation, and its interaction with the operating principles of pulse oximetry need further study. Importantly, clinicians should recognize the limitations of pulse oximetry and use additional objective measures of oxygenation (like co-oximetry measured arterial oxygen saturation) where hypoxia is a concern.
Collapse
Affiliation(s)
- Megha Sharma
- Department of Pediatrics, Division of Neonatology, University of Arkansas for Medical Sciences, Little Rock, AR, United States; Arkansas Children's Research Institute, Little Rock, AR, United States.
| | - Andrew W Brown
- Department of Biostatistics, University of Arkansas for Medical Sciences, Little Rock, AR, United States; Arkansas Children's Research Institute, Little Rock, AR, United States
| | - Nicholas M Powell
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, AR, United States
| | - Narasimhan Rajaram
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, AR, United States; Winthrop P. Rockefeller Cancer Institute, Little Rock, AR, United States
| | - Lauren Tong
- Clinical Library Services, University of Arkansas for Medical Sciences, Little Rock, AR, United States
| | - Peter M Mourani
- Arkansas Children's Research Institute, Little Rock, AR, United States; Department of Pediatrics, Division of Pediatric Critical Care, University of Arkansas for Medical Sciences, Little Rock, AR, United States
| | - Mario Schootman
- Department of Internal Medicine, University of Arkansas for Medical Sciences, Little Rock, AR, United States
| |
Collapse
|
7
|
Fernandez SV, Kim J, Sadat D, Marcus C, Suh E, Mclntosh R, Shah A, Dagdeviren C. A Dynamic Ultrasound Phantom with Tissue-Mimicking Mechanical and Acoustic Properties. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2400271. [PMID: 38647427 PMCID: PMC11165531 DOI: 10.1002/advs.202400271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 03/25/2024] [Indexed: 04/25/2024]
Abstract
Tissue-mimicking phantoms are valuable tools that aid in improving the equipment and training available to medical professionals. However, current phantoms possess limited utility due to their inability to precisely simulate multiple physical properties simultaneously, which is crucial for achieving a system understanding of dynamic human tissues. In this work, novel materials design and fabrication processes to produce various tissue-mimicking materials (TMMs) for skin, adipose, muscle, and soft tissue at a human scale are developed. Target properties (Young's modulus, density, speed of sound, and acoustic attenuation) are first defined for each TMM based on literature. Each TMM recipe is developed, associated mechanical and acoustic properties are characterized, and the TMMs are confirmed to have comparable mechanical and acoustic properties with the corresponding human tissues. Furthermore, a novel sacrificial core to fabricate a hollow, ellipsoid-shaped bladder phantom complete with inlet and outlet tubes, which allow liquids to flow through and expand this phantom, is adopted. This dynamic bladder phantom with realistic mechanical and acoustic properties to human tissues in combination with the developed skin, soft tissue, and subcutaneous adipose tissue TMMs, culminates in a human scale torso tank and electro-mechanical system that can be systematically utilized for characterizing various medical imaging devices.
Collapse
Affiliation(s)
- Sara V. Fernandez
- Media LabMassachusetts Institute of TechnologyCambridgeMA02139USA
- Department of Materials Science and EngineeringMassachusetts Institute of TechnologyCambridgeMA02139USA
| | - Jin‐Hoon Kim
- Media LabMassachusetts Institute of TechnologyCambridgeMA02139USA
| | - David Sadat
- Media LabMassachusetts Institute of TechnologyCambridgeMA02139USA
| | - Colin Marcus
- Media LabMassachusetts Institute of TechnologyCambridgeMA02139USA
- Department of Electrical Engineering and Computer ScienceMassachusetts Institute of TechnologyCambridgeMA02139USA
| | - Emma Suh
- Media LabMassachusetts Institute of TechnologyCambridgeMA02139USA
- Department of Mechanical EngineeringMassachusetts Institute of TechnologyCambridgeMA02139USA
| | - Rachel Mclntosh
- Media LabMassachusetts Institute of TechnologyCambridgeMA02139USA
- Department of Electrical Engineering and Computer ScienceMassachusetts Institute of TechnologyCambridgeMA02139USA
| | - Aastha Shah
- Media LabMassachusetts Institute of TechnologyCambridgeMA02139USA
| | - Canan Dagdeviren
- Media LabMassachusetts Institute of TechnologyCambridgeMA02139USA
| |
Collapse
|
8
|
Rodriguez AJ, Vasudevan S, Farahmand M, Weininger S, Vogt WC, Scully CG, Ramella-Roman J, Pfefer TJ. Tissue mimicking materials and finger phantom design for pulse oximetry. BIOMEDICAL OPTICS EXPRESS 2024; 15:2308-2327. [PMID: 38633081 PMCID: PMC11019708 DOI: 10.1364/boe.518967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 03/03/2024] [Accepted: 03/03/2024] [Indexed: 04/19/2024]
Abstract
Pulse oximetry represents a ubiquitous clinical application of optics in modern medicine. Recent studies have raised concerns regarding the potential impact of confounders, such as variable skin pigmentation and perfusion, on blood oxygen saturation measurement accuracy in pulse oximeters. Tissue-mimicking phantom testing offers a low-cost, well-controlled solution for characterizing device performance and studying potential error sources, which may thus reduce the need for costly in vivo trials. The purpose of this study was to develop realistic phantom-based test methods for pulse oximetry. Material optical and mechanical properties were reviewed, selected, and tuned for optimal biological relevance, e.g., oxygenated tissue absorption and scattering, strength, elasticity, hardness, and other parameters representing the human finger's geometry and composition, such as blood vessel size and distribution, and perfusion. Relevant anatomical and physiological properties are summarized and implemented toward the creation of a preliminary finger phantom. To create a preliminary finger phantom, we synthesized a high-compliance silicone matrix with scatterers for embedding flexible tubing and investigated the addition of these scatterers to novel 3D printing resins for optical property control without altering mechanical stability, streamlining the production of phantoms with biologically relevant characteristics. Phantom utility was demonstrated by applying dynamic, pressure waveforms to produce tube volume change and resultant photoplethysmography (PPG) signals. 3D printed phantoms achieved more biologically relevant conditions compared to molded phantoms. These preliminary results indicate that the phantoms show strong potential to be developed into tools for evaluating pulse oximetry performance. Gaps, recommendations, and strategies are presented for continued phantom development.
Collapse
Affiliation(s)
- Andres J. Rodriguez
- Department of Biomedical Engineering, Florida International University, Miami. Florida, 33174, USA
| | - Sandhya Vasudevan
- Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD 20993, USA
| | - Masoud Farahmand
- Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD 20993, USA
| | - Sandy Weininger
- Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD 20993, USA
| | - William C. Vogt
- Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD 20993, USA
| | - Christopher G. Scully
- Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD 20993, USA
| | - Jessica Ramella-Roman
- Department of Biomedical Engineering, Florida International University, Miami. Florida, 33174, USA
| | - T. Joshua Pfefer
- Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD 20993, USA
| |
Collapse
|
9
|
Devin KM, Tang J, Hamilton AR, Moser D, Jiang L. Assessment of 3D printed mechanical metamaterials for prosthetic liners. Proc Inst Mech Eng H 2024; 238:348-357. [PMID: 38279687 PMCID: PMC10941651 DOI: 10.1177/09544119231225529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Accepted: 12/21/2023] [Indexed: 01/28/2024]
Abstract
This study focuses on novel design and evaluation of Elastic 50A (EL50) mechanical metamaterials with open-cell patterns for its potential application to lower limb residuum/socket interfaces, specifically that of a transtibial (TT) amputee. Mechanical characteristics, that is, effective Young's modulus (E), was tuned by altering metamaterial porosity, which was experimentally verified. Specifically, pore radius of the unit cell was varied to achieve a range of E-values (0.05-1.71 MPa) for these 3D printed metamaterials. Finite Element Analysis (FEA) was conducted to evaluate pressure distribution across key load-bearing anatomical sites of a TT residuum. Using designed metamaterials for homogeneous liners, pressure profiles were studied and compared with a silicone liner case. Additionally, a custom metamaterial liner was designed by assigning appropriate metamaterials to four load-sensitive and tolerant anatomical sites of the TT residuum. The results suggest that lowest pressure variation (PV), as a measure of pressure distribution levels and potential comfort for amputees, was achieved by the custom metamaterial liner compared to any of the homogeneous liners included in this study. It is envisaged that this work may aid future design and development of custom liners using now commonly available 3D printing technologies and available elastomer materials to maximise comfort, tissue safety and overall rehabilitation outcomes for lower limb amputees.
Collapse
Affiliation(s)
- Kirstie M Devin
- School of Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
| | - Jinghua Tang
- School of Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
| | - Andrew R Hamilton
- School of Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
| | - David Moser
- School of Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
| | - Liudi Jiang
- School of Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
| |
Collapse
|
10
|
Bisht SR, Paul A, Patel P, Thareja P, Mercado-Shekhar KP. Systematic quantification of differences in shear wave elastography estimates between linear-elastic and viscoelastic material assumptionsa). THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:2025-2036. [PMID: 38470185 DOI: 10.1121/10.0025291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Accepted: 02/27/2024] [Indexed: 03/13/2024]
Abstract
Quantitative, accurate, and standardized metrics are important for reliable shear wave elastography (SWE)-based biomarkers. For over two decades, the linear-elastic material assumption has been employed in SWE modes. In recent years, viscoelasticity estimation methods have been adopted in a few clinical systems. The current study aims to systematically quantify differences in SWE estimates obtained using linear-elastic and viscoelastic material assumptions. An acousto-mechanical simulation framework of acoustic radiation force impulse-based SWE was created to elucidate the effect of material viscosity and shear modulus on SWE estimates. Shear modulus estimates exhibited errors up to 72% when a numerical viscoelastic phantom was assessed as linearly elastic. Shear modulus estimates of polyvinyl alcohol phantoms between rheometry and SWE following the Kelvin-Voigt viscoelastic model assumptions were not significantly different. However, the percentage difference in shear modulus estimates between rheometry and SWE using the linear-elastic assumption was 50.1%-62.1%. In ex vivo liver, the percentage difference in shear modulus estimates between linear-elastic and viscoelastic methods was 76.1%. These findings provide a direct and systematic quantification of the potential error introduced when viscoelastic tissues are imaged with SWE following the linear-elastic assumption. This work emphasizes the need to utilize viscoelasticity estimation methods for developing robust quantitative imaging biomarkers.
Collapse
Affiliation(s)
- Sapna R Bisht
- Department of Biological Sciences and Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat 382355, India
| | - Abhijit Paul
- Department of Biological Sciences and Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat 382355, India
| | - Panchami Patel
- Department of Chemical Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat 382355, India
| | - Prachi Thareja
- Department of Chemical Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat 382355, India
| | - Karla P Mercado-Shekhar
- Department of Biological Sciences and Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat 382355, India
| |
Collapse
|
11
|
Badawe HM, Raad P, Khraiche ML. High-resolution acoustic mapping of tunable gelatin-based phantoms for ultrasound tissue characterization. Front Bioeng Biotechnol 2024; 12:1276143. [PMID: 38456002 PMCID: PMC10917893 DOI: 10.3389/fbioe.2024.1276143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Accepted: 02/06/2024] [Indexed: 03/09/2024] Open
Abstract
Background: The choice of gelatin as the phantom material is underpinned by several key advantages it offers over other materials in the context of ultrasonic applications. Gelatin exhibits spatial and temporal uniformity, which is essential in creating reliable tissue-mimicking phantoms. Its stability ensures that the phantom's properties remain consistent over time, while its flexibility allows for customization to match the acoustic characteristics of specific tissues, in addition to its low levels of ultrasound scattering. These attributes collectively make gelatin a preferred choice for fabricating phantoms in ultrasound-related research. Methods: We developed gelatin-based phantoms with adjustable parameters and conducted high-resolution measurements of ultrasound wave attenuation when interacting with the gelatin phantoms. We utilized a motorized acoustic system designed for 3D acoustic mapping. Mechanical evaluation of phantom elasticity was performed using unconfined compression tests. We particularly examined how varying gelatin concentration influenced ultrasound maximal intensity and subsequent acoustic attenuation across the acoustic profile. To validate our findings, we conducted computational simulations to compare our data with predicted acoustic outcomes. Results: Our results demonstrated high-resolution mapping of ultrasound waves in both gelatin-based phantoms and plain fluid environments. Following an increase in the gelatin concentration, the maximum intensity dropped by 30% and 48% with the 5 MHz and 1 MHz frequencies respectively, while the attenuation coefficient increased, with 67% more attenuation at the 1 MHz frequency recorded at the highest concentration. The size of the focal areas increased systematically as a function of increasing applied voltage and duty cycle yet decreased as a function of increased ultrasonic frequency. Simulation results verified the experimental results with less than 10% deviation. Conclusion: We developed gelatin-based ultrasound phantoms as a reliable and reproducible tool for examining the acoustic and mechanical attenuations taking place as a function of increased tissue elasticity and stiffness. Our experimental measurements and simulations gave insight into the potential use of such phantoms for mimicking soft tissue properties.
Collapse
Affiliation(s)
| | | | - Massoud L. Khraiche
- Neural Engineering and Nanobiosensors Group, Biomedical Engineering Program, Maroun Semaan Faculty of Engineering and Architecture, American University of Beirut, Beirut, Lebanon
| |
Collapse
|
12
|
Lin Q, Li Z, Wang B, Zhou M, Xie Y, Wang D, Hou C, Wang R, Liu X, Sun X, Shan H, Chen Z, Wu H, Yang Y, Fei C, Chen Z. Acoustic hologram-induced virtual in vivo enhanced waveguide (AH-VIEW). SCIENCE ADVANCES 2024; 10:eadl2232. [PMID: 38354252 DOI: 10.1126/sciadv.adl2232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Accepted: 01/12/2024] [Indexed: 02/16/2024]
Abstract
Optical imaging and phototherapy in deep tissues face notable challenges due to light scattering. We use encoded acoustic holograms to generate three-dimensional acoustic fields within the target medium, enabling instantaneous and robust modulation of the volumetric refractive index, thereby noninvasively controlling the trajectory of light. Through this approach, we achieved a remarkable 24.3% increase in tissue heating rate in vitro photothermal effect tests on porcine skin. In vivo photoacoustic imaging of mouse brain vasculature exhibits an improved signal-to-noise ratio through the intact scalp and skull. These findings demonstrate that our strategy can effectively suppress light scattering in complex biological tissues by inducing low-angle scattering, achieving an effective depth reaching the millimeter scale. The versatility of this strategy extends its potential applications to neuroscience, lithography, and additive manufacturing.
Collapse
Affiliation(s)
- Qibo Lin
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Zhaoxi Li
- School of Microelectronics, Xidian University, Xi'an 710071, China
| | - Bo Wang
- Department of Biomedical Engineering, School of Basic Medical Science, Central South University, Changsha 410083, China
| | - Mengqing Zhou
- School of Microelectronics, Xidian University, Xi'an 710071, China
| | - Yang Xie
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Danfeng Wang
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Chenxue Hou
- School of Microelectronics, Xidian University, Xi'an 710071, China
| | - Runyu Wang
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Xiangdong Liu
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Xin Sun
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Han Shan
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Ziyan Chen
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Huayi Wu
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Yintang Yang
- School of Microelectronics, Xidian University, Xi'an 710071, China
| | - Chunlong Fei
- School of Microelectronics, Xidian University, Xi'an 710071, China
| | - Zeyu Chen
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
- Furong Laboratory (Precision Medicine), Changsha 410008, China
- National Engineering Research Center of Personalized Diagnostic and Therapeutic Technology, Xiangya Hospital, Central South University, Changsha 410008, China
- Hunan Engineering Research Center of Skin Health and Disease, Xiangya Hospital, Central South University, Changsha 410008, China
| |
Collapse
|
13
|
Gautam R, Ahmed R, Haugen E, Unal M, Fitzgerald S, Uppuganti S, Mahadevan-Jansen A, Nyman JS. Assessment of spatially offset Raman spectroscopy to detect differences in bone matrix quality. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 303:123240. [PMID: 37591015 PMCID: PMC10528408 DOI: 10.1016/j.saa.2023.123240] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 07/03/2023] [Accepted: 08/04/2023] [Indexed: 08/19/2023]
Abstract
Since spatially offset Raman spectroscopy (SORS) can acquire biochemical measurements of tissue quality through light scattering materials, we investigated the feasibility of this technique to acquire Raman bands related to the fracture resistance of bone. Designed to maximize signals at different offsets, a SORS probe was used to acquire spectra from cadaveric bone with and without skin-like tissue phantoms attenuating the light. Autoclaving the lateral side of femur mid-shafts from 5 female and 5 male donors at 100 °C and again at 120 °C reduced the yield stress of cortical beams subjected to three-point bending. It did not affect the volumetric bone mineral density or porosity. Without tissue phantoms, autoclaving affected more Raman characteristics of the organic matrix when determined by peak intensity ratios, but fewer matrix properties depended on the three offsets (5 mm, 6 mm, and 7 mm) when determined by band area ratios. The cut-off in the thickness of the tissue phantom layers was ∼4 mm for most properties, irrespective of offset. Matching trends when spectra were acquired without phantom layers between bone and the probe, ν1PO43-/Amide III and ν1PO43-/(proline + OH-proline) were higher and lower in the non-treated bone than in the autoclaved bone, respectively, when the thickness of tissue phantom layers was 4 mm. The layers, however, caused a loss of sensitivity to autoclaving-related changes in ν3CO3/ν1PO43- and crystallinity. Without advanced post-processing of Raman spectra, SORS acquisition through turbid layers can detect changes in Raman properties of bone that accompany a loss in bone strength.
Collapse
Affiliation(s)
- Rekha Gautam
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN 37232, USA; Biophotonics@Tyndall, IPIC, Tyndall National Institute, Cork, Ireland
| | - Rafay Ahmed
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, 1215 21st Ave. S., Suite 4200, Nashville, TN 37232, USA
| | - Ezekiel Haugen
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN 37232, USA
| | - Mustafa Unal
- Department of Bioengineering, Karamanoglu Mehmetbey University, Karaman, 70200, Turkey; Department of Biophysics, Faculty of Medicine, Karamanoglu Mehmetbey University, Karaman 70200, Turkey
| | - Sean Fitzgerald
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN 37232, USA
| | - Sasidhar Uppuganti
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, 1215 21st Ave. S., Suite 4200, Nashville, TN 37232, USA
| | - Anita Mahadevan-Jansen
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN 37232, USA; Vanderbilt Biophotonics Center, 410 24th Ave. S., Nashville, TN 37232, USA
| | - Jeffry S Nyman
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN 37232, USA; Department of Orthopaedic Surgery, Vanderbilt University Medical Center, 1215 21st Ave. S., Suite 4200, Nashville, TN 37232, USA; Department of Veterans Affairs, Tennessee Valley Healthcare System, 1310 24th Ave. S., Nashville, TN 37212, USA.
| |
Collapse
|
14
|
Haseeb F, Bourdakos KN, Forsyth E, Setchfield K, Gorman A, Venkateswaran S, Wright AJ, Mahajan S, Bradley M. Development of hydrogel-based standards and phantoms for non-linear imaging at depth. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:126007. [PMID: 38155703 PMCID: PMC10753126 DOI: 10.1117/1.jbo.28.12.126007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Revised: 08/23/2023] [Accepted: 08/28/2023] [Indexed: 12/30/2023]
Abstract
Significance Rapid advances in medical imaging technology, particularly the development of optical systems with non-linear imaging modalities, are boosting deep tissue imaging. The development of reliable standards and phantoms is critical for validation and optimization of these cutting-edge imaging techniques. Aim We aim to design and fabricate flexible, multi-layered hydrogel-based optical standards and evaluate advanced optical imaging techniques at depth. Approach Standards were made using a robust double-network hydrogel matrix consisting of agarose and polyacrylamide. The materials generated ranged from single layers to more complex constructs consisting of up to seven layers, with modality-specific markers embedded between the layers. Results These standards proved useful in the determination of the axial scaling factor for light microscopy and allowed for depth evaluation for different imaging modalities (conventional one-photon excitation fluorescence imaging, two-photon excitation fluorescence imaging, second harmonic generation imaging, and coherent anti-Stokes Raman scattering) achieving actual depths of 1550, 1550, 1240, and 1240 μ m , respectively. Once fabricated, the phantoms were found to be stable for many months. Conclusions The ability to image at depth, the phantom's robustness and flexible layered structure, and the ready incorporation of "optical markers" make these ideal depth standards for the validation of a variety of imaging modalities.
Collapse
Affiliation(s)
- Fizza Haseeb
- University of Edinburgh, School of Chemistry, Edinburgh, United Kingdom
| | - Konstantinos N. Bourdakos
- University of Southampton, School of Chemistry, Faculty of Engineering and Physical Sciences, Southampton, United Kingdom
| | - Ewan Forsyth
- University of Edinburgh, School of Chemistry, Edinburgh, United Kingdom
| | - Kerry Setchfield
- University of Nottingham, Faculty of Engineering, Optics and Photonics Research Group, Nottingham, United Kingdom
| | - Alistair Gorman
- University of Edinburgh, School of Engineering, Edinburgh, United Kingdom
| | - Seshasailam Venkateswaran
- University of Southampton, School of Chemistry, Faculty of Engineering and Physical Sciences, Southampton, United Kingdom
| | - Amanda J. Wright
- University of Nottingham, Faculty of Engineering, Optics and Photonics Research Group, Nottingham, United Kingdom
| | - Sumeet Mahajan
- University of Southampton, School of Chemistry, Faculty of Engineering and Physical Sciences, Southampton, United Kingdom
| | - Mark Bradley
- Queen Mary University of London, Precision Healthcare University Research Institute, London, United Kingdom
| |
Collapse
|
15
|
Kukk AF, Scheling F, Panzer R, Emmert S, Roth B. Combined ultrasound and photoacoustic C-mode imaging system for skin lesion assessment. Sci Rep 2023; 13:17947. [PMID: 37864039 PMCID: PMC10589211 DOI: 10.1038/s41598-023-44919-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Accepted: 10/13/2023] [Indexed: 10/22/2023] Open
Abstract
Accurate assessment of the size and depth of infiltration is critical for effectively treating and removing skin cancer, especially melanoma. However, existing methods such as skin biopsy and histologic examination are invasive, time-consuming, and may not provide accurate depth results. We present a novel system for simultaneous and co-localized ultrasound and photoacoustic imaging, with the application for non-invasive skin lesion size and depth measurement. The developed system integrates an acoustical mirror that is placed on an ultrasound transducer, which can be translated within a flexible water tank. This allows for 3D (C-mode) imaging, which is useful for mapping the skin structure and determine the invasion size and depth of lesions including skin cancer. For efficient reconstruction of photoacoustic images, we applied the open-source MUST library. The acquisition time per 2D image is <1 s and the pulse energies are below the legal Maximum Permissible Exposure (MPE) on human skin. We present the depth and resolution capabilities of the setup on several self-designed agar phantoms and demonstrate in vivo imaging on human skin. The setup also features an unobstructed optical window from the top, allowing for simple integration with other optical modalities. The perspective towards clinical application is demonstrated.
Collapse
Affiliation(s)
- Anatoly Fedorov Kukk
- Hannover Centre for Optical Technologies, Leibniz University of Hannover, Nienburger Straße 17, 30167, Hannover, Germany.
| | - Felix Scheling
- Hannover Centre for Optical Technologies, Leibniz University of Hannover, Nienburger Straße 17, 30167, Hannover, Germany
| | - Rüdiger Panzer
- Clinic and Policlinic for Dermatology and Venereology, University Medical Center Rostock, Strempelstraße 13, 18057, Rostock, Germany
| | - Steffen Emmert
- Clinic and Policlinic for Dermatology and Venereology, University Medical Center Rostock, Strempelstraße 13, 18057, Rostock, Germany
| | - Bernhard Roth
- Hannover Centre for Optical Technologies, Leibniz University of Hannover, Nienburger Straße 17, 30167, Hannover, Germany
- Cluster of Excellence PhoenixD (Photonics, Optics and Engineering - Innovation Across Disciplines), Welfengarten 1a, 30167, Hannover, Germany
| |
Collapse
|
16
|
Liu Y, Luo J. Experimental study on damage mechanism of blood vessel by cavitation bubbles. ULTRASONICS SONOCHEMISTRY 2023; 99:106562. [PMID: 37619475 PMCID: PMC10470397 DOI: 10.1016/j.ultsonch.2023.106562] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 07/31/2023] [Accepted: 08/16/2023] [Indexed: 08/26/2023]
Abstract
Ultrasound-induced cavitation in blood vessels is a common scenario in medical procedures. This paper focuses on understanding the mechanism of microscopic damage to vessel walls caused by the evolution of cavitation bubbles within the vessels. In this study, cavitation bubbles were generated using the low-voltage discharge method in 0.9% sodium chloride saline, and vessel models with wall thicknesses ranging from 0.7 mm to 2 mm were made using a 3D laminating process. The interaction between cavitation bubbles and vessel models with different wall thicknesses was observed using a combination of high-speed photography. Results show that cavitation bubble morphology and collapse time increased and then stabilized as the vessel wall thickness increased. When the cavitation bubble was located in vessel axial line, pair of opposing micro-jets were formed along the axis of the vessel, and the peak of micro-jet velocity decreased with increasing wall thickness. However, when the cavitation bubble deviated from the vessel model center, no micro-jet towards the vessel model wall was observed. Further analysis of the vessel wall deformation under varying distances from the cavitation bubble to the vessel wall revealed that the magnitude of vessel wall stretch due to the cavitation bubble expansion was greater than that of the contraction. A comparative analysis of the interaction of between the cavitation bubble and different forms of elastic membranes showed that the oscillation period of the cavitation bubble under the influence of elastic vessel model was lower than the elastic membrane. Furthermore, the degree of deformation of elastic vessel models under the expansion of the cavitation bubble was smaller than that of elastic membranes, whereas the degree of deformation of elastic vessel models in the contraction phase of the cavitation bubble was larger than that of elastic membranes. These new findings provide important theoretical insights into the microscopic mechanisms of blood vessel potential damage caused by ultrasound-induced cavitation bubble, as well as cavitation in pipelines in hydrodynamic systems.
Collapse
Affiliation(s)
- Yanyang Liu
- Department of General Surgery, Huashan Hospital, Fudan University, Shanghai, China.
| | - Jing Luo
- State Key Laboratory of Hydraulics and Mountain River Engineering, Sichuan University, Chengdu, China.
| |
Collapse
|
17
|
Al-Safadi S, Hutapea P. A study on modeling the deflection of surgical needle during insertion into multilayer tissues. J Mech Behav Biomed Mater 2023; 146:106071. [PMID: 37573763 DOI: 10.1016/j.jmbbm.2023.106071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 08/02/2023] [Accepted: 08/08/2023] [Indexed: 08/15/2023]
Abstract
The use of subcutaneous and percutaneous needle and catheter insertions is standard in modern clinical practice. However, a common issue with bevel tip surgical needles is their tendency to deflect, causing them to miss the intended target inside the tissue. This study aims to understand the interaction between the needle and soft tissue and develop a model to predict the deflection of a bevel tip needle during insertion into multi-layered soft tissues. The study examined the mechanics of needle-tissue interaction and modeled the forces involved during insertion. The force model includes cutting force, deformation force, and friction between the needle and tissue. There was an 8%-23% difference between the total analytical and experimental force measurements. A modified Euler-Bernoulli beam elastic foundation theory was used to create an analytical model to predict the needle tip deflection in soft tissue. To validate the results, the analytical deflection model was then compared to the deflection from needle insertion experiments on multi-layered phantom tissues, showing a 9%-21% error between the two. While there is a slight discrepancy between the analytical and experimental results, the study shows that the proposed model can accurately predict needle tip deflection during insertion.
Collapse
Affiliation(s)
- Samer Al-Safadi
- Department of Mechanical Engineering, Temple University, Philadelphia, PA, USA
| | - Parsaoran Hutapea
- Department of Mechanical Engineering, Temple University, Philadelphia, PA, USA.
| |
Collapse
|
18
|
Gautam R, Mac Mahon D, Eager G, Ma H, Guadagno CN, Andersson-Engels S, Konugolu Venkata Sekar S. Fabrication and characterization of multi-biomarker optimized tissue-mimicking phantoms for multi-modal optical spectroscopy. Analyst 2023; 148:4768-4776. [PMID: 37665320 DOI: 10.1039/d3an00680h] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/05/2023]
Abstract
Rapid advancement of novel optical spectroscopy and imaging systems relies on the availability of well-characterised and reproducible protocols for phantoms as a standard for the validation of the technique. The tissue-mimicking phantoms are also used to investigate photon transport in biological samples before clinical trials that require well-characterized phantoms with known optical properties (reduced scattering (μ's) and absorption (μa) coefficients). However, at present, there is limited literature available providing well-characterized phantom recipes considering various biomarkers and tested over a wide range of optical properties covering most of the human organs and applicable to multimodal optical spectroscopy. In this study, gelatin-based phantoms were designed to simulate tissue optical properties where India ink and Intralipid were used as absorbing and scattering agents, respectively. Multiple biomarkers were simulated by varying the gelatin concentration to mimic the change in tissue hydration and hydroxyapatite concentration to mimic bone signature. The recipe along with biomarkers were optimized and characterised over a wide range of optical properties (μa from 0.1 to 0.5 cm-1; μ's from 5 to 15 cm-1) relevant to human tissue using a broadband time-domain diffuse optical spectrometer. The data collected showed a linear relationship between the concentration of ink/lipids and μa/μ's values with negligible coupling between μa and μ's values. While being stored in a refrigerator post-fabrication, the μa and μ's did not change significantly (<4% coefficient of variation, 'CV') over three weeks. The reproducibility in three different sets was validated experimentally and found to be strong with a variation of ≤6% CV in μa and ≤9% CV in μ's. From the 3 × 3 data of μa and μ's matrices, one can deduce the recipe for any target absorption or reduced scattering coefficient. The applicability of the phantoms was tested using diffuse reflectance and Raman spectrometers. A use case application was demonstrated for Raman spectroscopy where hydration and hydroxyapatite phantoms were designed to characterize the Raman instrument. The Raman instrument could detect the change in 1% of HA and 5% of hydration. This study presents a first-of-its-kind robust, well-characterized, multi-biomarker phantom recipe for calibration and benchmarking of multimodal spectroscopy devices assisting in their clinical translation.
Collapse
Affiliation(s)
- Rekha Gautam
- Biophotonics@Tyndall, IPIC, Tyndall National Institute, T12 R5CP Cork, Ireland.
| | | | - Gráinne Eager
- School of Physics, Trinity College Dublin, Dublin 2, Ireland
| | - Hui Ma
- Biophotonics@Tyndall, IPIC, Tyndall National Institute, T12 R5CP Cork, Ireland.
| | | | - Stefan Andersson-Engels
- Biophotonics@Tyndall, IPIC, Tyndall National Institute, T12 R5CP Cork, Ireland.
- Department of Physics, University College Cork, T12 K8AF Cork, Ireland
| | | |
Collapse
|
19
|
Morsink CF, Dam-Vervloet AJ, Krommendijk ME, Kaya M, Cuartas-Vélez C, Knop T, Francis KJ, Bosschaart N. Design and characterization of color printed polyurethane films as biomedical phantom layers. BIOMEDICAL OPTICS EXPRESS 2023; 14:4485-4506. [PMID: 37791261 PMCID: PMC10545194 DOI: 10.1364/boe.491695] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 06/30/2023] [Accepted: 07/05/2023] [Indexed: 10/05/2023]
Abstract
We propose a new, user-friendly and accessible approach for fabricating thin phantoms with controllable absorption properties in magnitude, spectral shape, and spatial distribution. We utilize a standard office laser color printer to print on polyurethane thin films (40 - 60 μm), commonly available as medical film dressings and ultrasound probe covers. We demonstrate that the optical attenuation and absorption of the printed films correlate linearly with the printer input settings (opacity), which facilitates a systematic phantom design. The optical and acoustic properties of these polyurethane films are similar to biological tissue. We argue that these thin phantoms are applicable to a wide range of biomedical applications. Here, we introduce two potential applications: (1) homogeneous epidermal melanin phantoms and (2) spatially resolved absorbers for photoacoustic imaging. We characterize the thin phantoms in terms of optical properties, thickness, microscopic structure, and reproducibility of the printing process.
Collapse
Affiliation(s)
- Claudia F. Morsink
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| | - Alida J. Dam-Vervloet
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
- Medical Physics Department, Isala Hospital, Zwolle, The Netherlands
| | - Marleen E. Krommendijk
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| | - Michael Kaya
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| | - Carlos Cuartas-Vélez
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| | - Tom Knop
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| | - Kalloor Joseph Francis
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| | - Nienke Bosschaart
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| |
Collapse
|
20
|
Le TD, Min JJ, Lee C. Enhanced resolution and sensitivity acoustic-resolution photoacoustic microscopy with semi/unsupervised GANs. Sci Rep 2023; 13:13423. [PMID: 37591911 PMCID: PMC10435476 DOI: 10.1038/s41598-023-40583-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Accepted: 08/13/2023] [Indexed: 08/19/2023] Open
Abstract
Acoustic-resolution photoacoustic microscopy (AR-PAM) enables visualization of biological tissues at depths of several millimeters with superior optical absorption contrast. However, the lateral resolution and sensitivity of AR-PAM are generally lower than those of optical-resolution PAM (OR-PAM) owing to the intrinsic physical acoustic focusing mechanism. Here, we demonstrate a computational strategy with two generative adversarial networks (GANs) to perform semi/unsupervised reconstruction with high resolution and sensitivity in AR-PAM by maintaining its imaging capability at enhanced depths. The b-scan PAM images were prepared as paired (for semi-supervised conditional GAN) and unpaired (for unsupervised CycleGAN) groups for label-free reconstructed AR-PAM b-scan image generation and training. The semi/unsupervised GANs successfully improved resolution and sensitivity in a phantom and in vivo mouse ear test with ground truth. We also confirmed that GANs could enhance resolution and sensitivity of deep tissues without the ground truth.
Collapse
Affiliation(s)
- Thanh Dat Le
- Department of Artificial Intelligence Convergence, Chonnam National University, Gwangju, 61186, Korea
| | - Jung-Joon Min
- Department of Nuclear Medicine, Chonnam National University Medical School and Hwasun Hospital, 264, Seoyang-ro, Hwasun-eup, Hwasun-gun, 58128, Jeollanam-do, Korea
| | - Changho Lee
- Department of Artificial Intelligence Convergence, Chonnam National University, Gwangju, 61186, Korea.
- Department of Nuclear Medicine, Chonnam National University Medical School and Hwasun Hospital, 264, Seoyang-ro, Hwasun-eup, Hwasun-gun, 58128, Jeollanam-do, Korea.
| |
Collapse
|
21
|
Biswas B, Rana A, Gupta N, Gupta I, Puria R, Thakur A. A Novel Robust Method Mimicking Human Substratum To Dissect the Heterogeneity of Candida auris Biofilm Formation. Microbiol Spectr 2023; 11:e0089223. [PMID: 37439683 PMCID: PMC10434199 DOI: 10.1128/spectrum.00892-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Accepted: 06/21/2023] [Indexed: 07/14/2023] Open
Abstract
Candida auris is a pathogen of urgent threat level as marked by the CDC. The formation of biofilms is an essential property of this fungus to establish infection and escape drug treatment. However, our understanding of pathogenesis through biofilm is hampered by heterogeneity in C. auris biofilms observed in different studies. It is imperative to replicate in vivo conditions for studying C. auris biofilm formation in vitro. Different methods are standardized, but the surface used to form biofilms lacks consistency as well as the architecture of a typical biofilm. Here, we report an in vitro technique to grow C. auris biofilms on gelatin-coated coverslips. Interestingly, C. auris cells grown on gelatin-coated coverslips either on modified synthetic sweat media or RPMI 1640 resulted in similar multilayer biofilm formation with extracellular polymeric substances (EPS). This method is also consistent with the biofilm formation of other Candida species, such as Candida glabrata and Candida albicans. Biofilms of C. glabrata developed through this method show pseudohyphae and EPS. This method can be used to understand the molecular basis of biofilm formation, associated pathogenesis, and drug tolerance. The technique is cost-effective and would thus serve in rightful screening and repurposing drug libraries for designing new therapeutics against the less-studied high-alarm pathogen C. auris. IMPORTANCE Heterogeneity is seen when multidrug-resistant C. auris biofilm is cultured using different reported methods. Biofilm formed on the gelatin surface mimics the condition of a host environment that has multilayers and EPS. This method has feasibility for drug screening and analyzing biofilms through three-dimensional (3D) reconstruction. This in vitro biofilm formation technique is also exploited to study the formation of biofilm of other Candida species. The biofilms of C. glabrata and C. albicans can also be correctly mimicked using gelatin in the biofilm-forming environment. Thus, the novel in vitro method for biofilm formation reported here can be widely used to understand the mechanism of biofilm formation, related virulence properties, and drug tolerance of C. auris and other Candida species. This simple and low-cost technique is highly suitable for screening novel inhibitors and repurposed libraries and to design new therapeutics against Candida species.
Collapse
Affiliation(s)
- Biswambhar Biswas
- Laboratory of Protein Translation and Fungal Pathogenesis, Regional Centre for Biotechnology, Faridabad, Haryana, India
| | - Aishwarya Rana
- Laboratory of Protein Translation and Fungal Pathogenesis, Regional Centre for Biotechnology, Faridabad, Haryana, India
| | - Nidhi Gupta
- Laboratory of Protein Translation and Fungal Pathogenesis, Regional Centre for Biotechnology, Faridabad, Haryana, India
| | - Ishaan Gupta
- Department of Biochemical Engineering and Biotechnology, Indian Institute of Technology Delhi, Delhi, India
| | - Rekha Puria
- School of Biotechnology, Gautam Buddha University, Greater Noida, Uttar Pradesh, India
| | - Anil Thakur
- Laboratory of Protein Translation and Fungal Pathogenesis, Regional Centre for Biotechnology, Faridabad, Haryana, India
| |
Collapse
|
22
|
Christie LB, Zheng W, Johnson W, Marecki EK, Heidrich J, Xia J, Oh KW. Review of imaging test phantoms. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:080903. [PMID: 37614568 PMCID: PMC10442662 DOI: 10.1117/1.jbo.28.8.080903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 07/31/2023] [Accepted: 08/04/2023] [Indexed: 08/25/2023]
Abstract
Significance Photoacoustic tomography has emerged as a prominent medical imaging technique that leverages its hybrid nature to provide deep penetration, high resolution, and exceptional optical contrast with notable applications in early cancer detection, functional brain imaging, drug delivery monitoring, and guiding interventional procedures. Test phantoms are pivotal in accelerating technology development and commercialization, specifically in photoacoustic (PA) imaging, and can be optimized to achieve significant advancements in PA imaging capabilities. Aim The analysis of material properties, structural characteristics, and manufacturing methodologies of test phantoms from existing imaging technologies provides valuable insights into their applicability to PA imaging. This investigation enables a deeper understanding of how phantoms can be effectively employed in the context of PA imaging. Approach Three primary categories of test phantoms (simple, intermediate, and advanced) have been developed to differentiate complexity and manufacturing requirements. In addition, four sub-categories (tube/channel, block, test target, and naturally occurring phantoms) have been identified to encompass the structural variations within these categories, resulting in a comprehensive classification system for test phantoms. Results Based on a thorough examination of literature and studies on phantoms in various imaging modalities, proposals have been put forth for the development of multiple PA-capable phantoms, encompassing considerations related to the material composition, structural design, and specific applications within each sub-category. Conclusions The advancement of novel and sophisticated test phantoms within each sub-category is poised to foster substantial progress in both the commercialization and development of PA imaging. Moreover, the continued refinement of test phantoms will enable the exploration of new applications and use cases for PA imaging.
Collapse
Affiliation(s)
- Liam B. Christie
- State University of New York at Buffalo, Sensors and MicroActuators Learning Lab, Electrical Engineering, Buffalo, New York, United States
| | - Wenhan Zheng
- State University of New York at Buffalo, Optical and Ultrasonic Imaging Laboratory, Biomedical Engineering, Buffalo, New York, United States
| | - William Johnson
- State University of New York at Buffalo, Sensors and MicroActuators Learning Lab, Electrical Engineering, Buffalo, New York, United States
| | - Eric K. Marecki
- State University of New York at Buffalo, Sensors and MicroActuators Learning Lab, Electrical Engineering, Buffalo, New York, United States
| | - James Heidrich
- State University of New York at Buffalo, Sensors and MicroActuators Learning Lab, Electrical Engineering, Buffalo, New York, United States
| | - Jun Xia
- State University of New York at Buffalo, Optical and Ultrasonic Imaging Laboratory, Biomedical Engineering, Buffalo, New York, United States
| | - Kwang W. Oh
- State University of New York at Buffalo, Sensors and MicroActuators Learning Lab, Electrical Engineering, Buffalo, New York, United States
| |
Collapse
|
23
|
Jenne S, Zappe H. Multiwavelength tissue-mimicking phantoms with tunable vessel pulsation. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:045003. [PMID: 37077500 PMCID: PMC10109273 DOI: 10.1117/1.jbo.28.4.045003] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Accepted: 03/26/2023] [Indexed: 05/03/2023]
Abstract
Significance For the development and routine characterization of optical devices used in medicine, tissue-equivalent phantoms mimicking a broad spectrum of human skin properties are indispensable. Aim Our work aims to develop a tissue-equivalent phantom suitable for photoplethysmography applications. The phantom includes the optical and mechanical properties of the three uppermost human skin layers (dermis, epidermis, and hypodermis, each containing different types of blood vessels) plus the ability to mimic pulsation. Approach While the mechanical properties of the polydimethylsiloxane base material are adjusted by different mixing ratios of a base and curing agent, the optical properties are tuned by adding titanium dioxide particles, India ink, and synthetic melanin in different concentrations. The layered structure of the phantom is realized using a doctor blade technique, and blood vessels are fabricated using molding wires of different diameters. The tissue-mimicking phantom is then integrated into an artificial circulatory system employing piezo-actuated double diaphragm pumps for testing. Results The optical and mechanical properties of human skin were successfully replicated. The diameter of the artificial blood vessels is linearly dependent on pump actuation, and the time-dependent expansion profile of real pulse forms were mimicked. Conclusions A tissue equivalent phantom suitable for the ex-vivo testing of opto-medical devices was demonstrated.
Collapse
Affiliation(s)
- Sophie Jenne
- University of Freiburg, Department of Microsystems Engineering—IMTEK, Gisela and Erwin Sick Chair of Micro-Optics, Freiburg, Germany
- Address all correspondence to Sophie Jenne,
| | - Hans Zappe
- University of Freiburg, Department of Microsystems Engineering—IMTEK, Gisela and Erwin Sick Chair of Micro-Optics, Freiburg, Germany
| |
Collapse
|
24
|
Wickramasinghe VA, Decker SM, Streeter SS, Sloop AM, Petusseau AF, Alexander DA, Bruza P, Gladstone DJ, Zhang R, Pogue BW. Color-resolved Cherenkov imaging allows for differential signal detection in blood and melanin content. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:036005. [PMID: 36923987 PMCID: PMC10008915 DOI: 10.1117/1.jbo.28.3.036005] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Accepted: 02/15/2023] [Indexed: 06/18/2023]
Abstract
Significance High-energy x-ray delivery from a linear accelerator results in the production of spectrally continuous broadband Cherenkov light inside tissue. In the absence of attenuation, there is a linear relationship between Cherenkov emission and deposited dose; however, scattering and absorption result in the distortion of this linear relationship. As Cherenkov emission exits the absorption by tissue dominates the observed Cherenkov emission spectrum. Spectroscopic interpretation of this effects may help to better relate Cherenkov emission to ionizing radiation dose delivered during radiotherapy. Aim In this study, we examined how color Cherenkov imaging intensity variations are caused by absorption from both melanin and hemoglobin level variations, so that future Cherenkov emission imaging might be corrected for linearity to delivered dose. Approach A custom, time-gated, three-channel intensified camera was used to image the red, green, and blue wavelengths of Cherenkov emission from tissue phantoms with synthetic melanin layers and varying blood concentrations. Our hypothesis was that spectroscopic separation of Cherenkov emission would allow for the identification of attenuated signals that varied in response to changes in blood content versus melanin content, because of their different characteristic absorption spectra. Results Cherenkov emission scaled with dose linearly in all channels. Absorption in the blue and green channels increased with increasing oxy-hemoglobin in the blood to a greater extent than in the red channel. Melanin was found to absorb with only slight differences between all channels. These spectral differences can be used to derive dose from measured Cherenkov emission. Conclusions Color Cherenkov emission imaging may be used to improve the optical measurement and determination of dose delivered in tissues. Calibration for these factors to minimize the influence of the tissue types and skin tones may be possible using color camera system information based upon the linearity of the observed signals.
Collapse
Affiliation(s)
| | - Savannah M. Decker
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - Samuel S. Streeter
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - Austin M. Sloop
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - Arthur F. Petusseau
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - Daniel A. Alexander
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - Petr Bruza
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - David J. Gladstone
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
- Dartmouth College, Geisel School of Medicine, Department of Medicine, Hanover, New Hampshire, United States
| | - Rongxiao Zhang
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
- Dartmouth College, Geisel School of Medicine, Department of Medicine, Hanover, New Hampshire, United States
| | - Brian W. Pogue
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
- University of Wisconsin–Madison, Department of Medical Physics, Madison, Wisconsin, United States
| |
Collapse
|
25
|
Sharma A, Marapureddy SG, Paul A, Bisht SR, Kakkar M, Thareja P, Mercado-Shekhar KP. Characterizing Viscoelastic Polyvinyl Alcohol Phantoms for Ultrasound Elastography. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:497-511. [PMID: 36328889 DOI: 10.1016/j.ultrasmedbio.2022.09.019] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 09/22/2022] [Accepted: 09/24/2022] [Indexed: 06/16/2023]
Abstract
Ultrasound phantoms mimic the acoustic and mechanical properties of native tissues. Polyvinyl alcohol (PVA) phantoms are used extensively as models for validating ultrasound elastography approaches. However, the viscous properties of PVA phantoms have not been investigated adequately. Glycerol is a viscous liquid that has been reported to increase the speed of sound of phantoms. This study aims to assess the acoustic and viscoelastic properties of PVA phantoms and PVA mixed with glycerol at varying concentrations. The phantoms were fabricated with 10% w/v PVA in water with varying concentrations of glycerol (10%, 15% and 20% v/v) and 2% w/v silicon carbide particles as acoustic scatterers. The phantoms were subjected to either one, two, or three 24-h freeze-thaw cycles. The longitudinal sound speeds of all PVA phantoms were measured, and ranged from 1529 to 1660 m/s. Attenuation spectroscopy was performed in the range of 5 to 20 MHz. The measured attenuation followed a power-law relationship with frequency, wherein the power-law fit constants and exponents ranged from 0.02 to 0.1 dB/cm/MHzn and from 1.6 to 1.9, respectively. These results were in agreement with previous reports for soft tissues. Viscoelasticity of PVA phantoms was assessed using rheometry. The estimated values of shear modulus and viscosity using the Kelvin-Voigt and Kelvin-Voigt fractional derivative models were within the range of previously-reported tissue-mimicking phantoms and soft tissues. The number of freeze-thaw cycles were shown to alter the viscosity of PVA phantoms, even in the absence of glycerol. Scanning electron microscopy images of PVA phantoms without glycerol showed a porous hydrogel network, in contrast to those of PVA-glycerol phantoms with non-porous structure. Phantoms fabricated in this study possess tunable acoustic and viscoelastic properties within the range reported for healthy and diseased soft tissues. This study demonstrates that PVA phantoms can be manufactured with glycerol for applications in ultrasound elastography.
Collapse
Affiliation(s)
- Ananya Sharma
- Discipline of Biological Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat, India
| | - Sai Geetha Marapureddy
- Discipline of Chemical Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat, India
| | - Abhijit Paul
- Discipline of Biological Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat, India
| | - Sapna R Bisht
- Discipline of Biological Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat, India
| | - Manik Kakkar
- Discipline of Electrical Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat, India
| | - Prachi Thareja
- Discipline of Chemical Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat, India
| | - Karla P Mercado-Shekhar
- Discipline of Biological Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat, India.
| |
Collapse
|
26
|
Arteaga-Marrero N, Villa E, Llanos González AB, Gómez Gil ME, Fernández OA, Ruiz-Alzola J, González-Fernández J. Low-Cost Pseudo-Anthropomorphic PVA-C and Cellulose Lung Phantom for Ultrasound-Guided Interventions. Gels 2023; 9:gels9020074. [PMID: 36826245 PMCID: PMC9957311 DOI: 10.3390/gels9020074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 01/11/2023] [Accepted: 01/13/2023] [Indexed: 01/19/2023] Open
Abstract
A low-cost custom-made pseudo-anthropomorphic lung phantom, offering a model for ultrasound-guided interventions, is presented. The phantom is a rectangular solidstructure fabricated with polyvinyl alcohol cryogel (PVA-C) and cellulose to mimic the healthy parenchyma. The pathologies of interest were embedded as inclusions containing gaseous, liquid, or solid materials. The ribs were 3D-printed using polyethylene terephthalate, and the pleura was made of a bidimensional reticle based on PVA-C. The healthy and pathological tissues were mimicked to display acoustic and echoic properties similar to that of soft tissues. Theflexible fabrication process facilitated the modification of the physical and acoustic properties of the phantom. The phantom's manufacture offers flexibility regarding the number, shape, location, and composition of the inclusions and the insertion of ribs and pleura. In-plane and out-of-plane needle insertions, fine needle aspiration, and core needle biopsy were performed under ultrasound image guidance. The mimicked tissues displayed a resistance and recoil effect typically encountered in a real scenario for a pneumothorax, abscesses, and neoplasms. The presented phantom accurately replicated thoracic tissues (lung, ribs, and pleura) and associated pathologies providing a useful tool for training ultrasound-guided procedures.
Collapse
Affiliation(s)
- Natalia Arteaga-Marrero
- Grupo Tecnología Médica IACTEC, Instituto de Astrofísica de Canarias (IAC), 38205 San Cristóbal de La Laguna, Spain
| | - Enrique Villa
- Grupo Tecnología Médica IACTEC, Instituto de Astrofísica de Canarias (IAC), 38205 San Cristóbal de La Laguna, Spain
- Correspondence:
| | - Ana Belén Llanos González
- Departamento de Neumología, Complejo Universitario de Canarias (HUC), 38320 San Cristóbal de La Laguna, Spain
| | - Marta Elena Gómez Gil
- Departameto de Radiología, Complejo Universitario de Canarias (HUC), 38320 San Cristóbal de La Laguna, Spain
| | - Orlando Acosta Fernández
- Departamento de Neumología, Complejo Universitario de Canarias (HUC), 38320 San Cristóbal de La Laguna, Spain
| | - Juan Ruiz-Alzola
- Grupo Tecnología Médica IACTEC, Instituto de Astrofísica de Canarias (IAC), 38205 San Cristóbal de La Laguna, Spain
- Instituto Universitario de Investigaciones Biomédicas y Sanitarias (IUIBS), Universidad de Las Palmas de Gran Canaria, 35016 Las Palmas de Gran Canaria, Spain
- Departamento de Señales y Comunicaciones, Universidad de Las Palmas de Gran Canaria, 35016 Las Palmas de Gran Canaria, Spain
| | - Javier González-Fernández
- Departamento de Ingeniería Biomédica, Instituto Tecnológico de Canarias (ITC), 38009 Santa Cruz de Tenerife, Spain
| |
Collapse
|
27
|
Armstrong SA, Jafary R, Forsythe JS, Gregory SD. Tissue-Mimicking Materials for Ultrasound-Guided Needle Intervention Phantoms: A Comprehensive Review. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:18-30. [PMID: 36210247 DOI: 10.1016/j.ultrasmedbio.2022.07.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 07/07/2022] [Accepted: 07/30/2022] [Indexed: 06/16/2023]
Abstract
Ultrasound-guided needle interventions are common procedures in medicine, and tissue-mimicking phantoms are widely used for simulation training to bridge the gap between theory and clinical practice in a controlled environment. This review assesses tissue-mimicking materials from 24 studies as candidates for a high-fidelity ultrasound phantom, including methods for evaluating relevant acoustic and mechanical properties and to what extent the reported materials mimic the superficial layers of biological tissue. Speed of sound, acoustic attenuation, Young's modulus, hardness, needle interaction forces, training efficiency and material limitations were systematically evaluated. Although gelatin and agar have the closest acoustic values to tissue, mechanical properties are limited, and strict storage protocols must be employed to counteract dehydration and microbial growth. Polyvinyl chloride (PVC) has superior mechanical properties and is a suitable alternative if durability is desired and some ultrasound realism to human tissue may be sacrificed. Polyvinyl alcohol (PVA), while also requiring hydration, performs well across all categories. Furthermore, we propose a framework for the evaluation of future ultrasound-guided needle intervention tissue phantoms to increase the fidelity of training programs and thereby improve clinical performance.
Collapse
Affiliation(s)
- Sophie A Armstrong
- Department of Mechanical and Aerospace Engineering, Monash University, Clayton, Victoria, Australia; Cardio-respiratory Engineering and Technology Laboratory (CREATElab), Baker Heart and Diabetes Institute, Melbourne, Victoria, Australia.
| | - Rezan Jafary
- Department of Mechanical and Aerospace Engineering, Monash University, Clayton, Victoria, Australia; Cardio-respiratory Engineering and Technology Laboratory (CREATElab), Baker Heart and Diabetes Institute, Melbourne, Victoria, Australia
| | - John S Forsythe
- Department of Materials Science and Engineering, Monash University, Clayton, Victoria, Australia
| | - Shaun D Gregory
- Department of Mechanical and Aerospace Engineering, Monash University, Clayton, Victoria, Australia; Cardio-respiratory Engineering and Technology Laboratory (CREATElab), Baker Heart and Diabetes Institute, Melbourne, Victoria, Australia
| |
Collapse
|
28
|
Yim W, Zhou J, Sasi L, Zhao J, Yeung J, Cheng Y, Jin Z, Johnson W, Xu M, Palma-Chavez J, Fu L, Qi B, Retout M, Shah NJ, Bae J, Jokerst JV. 3D-Bioprinted Phantom with Human Skin Phototypes for Biomedical Optics. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2206385. [PMID: 36305604 PMCID: PMC9868107 DOI: 10.1002/adma.202206385] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 10/21/2022] [Indexed: 06/16/2023]
Abstract
3D-bioprinted skin-mimicking phantoms with skin colors ranging across the Fitzpatrick scale are reported. These tools can help understand the impact of skin phototypes on biomedical optics. Synthetic melanin nanoparticles of different sizes (70-500 nm) and clusters are fabricated to mimic the optical behavior of melanosome. The absorption coefficient and reduced scattering coefficient of the phantoms are comparable to real human skin. Further the melanin content and distribution in the phantoms versus real human skins are validated via photoacoustic (PA) imaging. The PA signal of the phantom can be improved by: 1) increasing melanin size (3-450-fold), 2) increasing clustering (2-10.5-fold), and 3) increasing concentration (1.3-8-fold). Then, multiple biomedical optics tools (e.g., PA, fluorescence imaging, and photothermal therapy) are used to understand the impact of skin tone on these modalities. These well-defined 3D-bioprinted phantoms may have value in translating biomedical optics and reducing racial bias.
Collapse
Affiliation(s)
- Wonjun Yim
- Materials Science and Engineering Program, University of California San Diego, La Jolla, CA, USA
| | - Jiajing Zhou
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, USA
| | - Lekshmi Sasi
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, USA
| | - Jiayu Zhao
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, USA
| | - Justin Yeung
- Department of Bioengineering, University of California San Diego, La Jolla, CA, USA
| | - Yong Cheng
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, USA
| | - Zhicheng Jin
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, USA
| | - Wade Johnson
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, USA
| | - Ming Xu
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, USA
| | - Jorge Palma-Chavez
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, USA
| | - Lei Fu
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, USA
| | - Baiyan Qi
- Materials Science and Engineering Program, University of California San Diego, La Jolla, CA, USA
| | - Maurice Retout
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, USA
| | - Nisarg J. Shah
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, USA
- Chemical Engineering Program, University of California San Diego, La Jolla, CA, USA
| | - Jinhye Bae
- Materials Science and Engineering Program, University of California San Diego, La Jolla, CA, USA
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, USA
- Chemical Engineering Program, University of California San Diego, La Jolla, CA, USA
| | - Jesse V. Jokerst
- Materials Science and Engineering Program, University of California San Diego, La Jolla, CA, USA
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, USA
- Chemical Engineering Program, University of California San Diego, La Jolla, CA, USA
- Department of Radiology, University of California San Diego, La Jolla, CA, USA
| |
Collapse
|
29
|
Tsunoi Y, Sato N, Nishidate I, Ichihashi F, Saitoh D, Sato S. Burn depth assessment by dual-wavelength light emitting diodes-excited photoacoustic imaging in rats. Wound Repair Regen 2023; 31:69-76. [PMID: 36177703 DOI: 10.1111/wrr.13056] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 08/14/2022] [Accepted: 09/11/2022] [Indexed: 02/01/2023]
Abstract
Accurate burn depth assessment is crucial to determine treatment plans for burn patients. We have previously proposed a method for performing burn depth assessments based on photoacoustic (PA) imaging, and we have demonstrated the validity of this method, which allows the successful detection of PA signals originating from the blood under the bloodless burned tissue, using rat burn models. Based on these findings, we started a clinical study in which we faced two technical issues: (1) When the burn depth was shallow, PA signals due to skin contamination and/or melanin in the epidermis (surface signals) could not be distinguished from PA signals originating from the blood in the dermis; (2) the size of the system was too large. To solve these issues, we propose a burn depth diagnosis based on dual-wavelength light emitting diodes (LEDs)-excited PA imaging. The use of LEDs rendered the system compact compared to the previous one that used a conventional solid-state laser. We replicated human burned skin by applying a titrated synthetic melanin solution onto the wound surface in albino rat burn models and measured their burn depths by PA excitation at 690 and 850 nm, where melanin and haemoglobin show greatly different absorption coefficients. As a result, the surface signals were eliminated by subtracting the PA signals at 690 nm from those at 850 nm. The resultant estimated burn depths were strongly correlated with the histological assessment results. The validity of the proposed method was also examined using a burn model of rats with real melanin.
Collapse
Affiliation(s)
- Yasuyuki Tsunoi
- Division of Bioinformation and Therapeutic Systems, National Defense Medical College Research Institute, Tokorozawa, Saitama, Japan
| | - Naoto Sato
- Research and Development Department, Cyberdyne, Inc, Tsukuba, Ibaraki, Japan
| | - Izumi Nishidate
- Graduate School of Bio-application and Systems Engineering, Tokyo University of Agriculture and Technology, Fuchu, Tokyo, Japan
| | - Fumiyuki Ichihashi
- Research and Development Department, Cyberdyne, Inc, Tsukuba, Ibaraki, Japan
| | - Daizoh Saitoh
- Division of Basic Traumatology, National Defense Medical College Research Institute, Tokorozawa, Saitama, Japan
| | - Shunichi Sato
- Division of Bioinformation and Therapeutic Systems, National Defense Medical College Research Institute, Tokorozawa, Saitama, Japan
| |
Collapse
|
30
|
Caratenuto A, Li S, Wan Y, Zheng Y. Optical Epidermal Mimicry from Ultraviolet to Infrared Wavelengths. ACS APPLIED BIO MATERIALS 2022; 5:5231-5239. [PMID: 36331184 DOI: 10.1021/acsabm.2c00660] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Optical tissue phantoms present substantial value for medical imaging and therapeutic applications. We have developed an epidermal tissue phantom to mimic the optical properties of human skin from the ultraviolet to the infrared region, exceeding the breadth of existing studies. An epoxy matrix is combined with melanin-mimicking polydopamine via a cost-effective fabrication strategy. Reflectance and transmittance measurements enable calculation of the wavelength-dependent complex refractive index and absorption coefficient. Results are compared with literature data to establish agreement with a real human epidermis. By analyzing emissive power at a typical skin temperature, the epidermal tissue phantom is shown to accurately mimic the radiative properties of human skin. This simple, multifunctional material represents a promising substitute for human tissue for a variety of medical and bioengineering applications.
Collapse
Affiliation(s)
- Andrew Caratenuto
- Department of Mechanical and Industrial Engineering, Northeastern University, Boston, Massachusetts02115, United States
| | - Su Li
- Department of Mechanical and Industrial Engineering, Northeastern University, Boston, Massachusetts02115, United States
| | - Yinsheng Wan
- Department of Biology, Providence College, Providence, Rhode Island02918, United States
| | - Yi Zheng
- Department of Mechanical and Industrial Engineering, Northeastern University, Boston, Massachusetts02115, United States.,Department of Chemical Engineering, Northeastern University, Boston, Massachusetts02115, United States
| |
Collapse
|
31
|
Robotic needle steering: state-of-the-art and research challenges. INTEL SERV ROBOT 2022. [DOI: 10.1007/s11370-022-00446-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
32
|
Fedorov Kukk A, Wu D, Gaffal E, Panzer R, Emmert S, Roth B. Multimodal system for optical biopsy of melanoma with integrated ultrasound, optical coherence tomography and Raman spectroscopy. JOURNAL OF BIOPHOTONICS 2022; 15:e202200129. [PMID: 35802400 DOI: 10.1002/jbio.202200129] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 06/20/2022] [Accepted: 06/22/2022] [Indexed: 06/15/2023]
Abstract
We introduce a new single-head multimodal optical system that integrates optical coherence tomography (OCT), 18 MHz ultrasound (US) tomography and Raman spectroscopy (RS), allowing for fast (<2 min) and noninvasive skin cancer diagnostics and lesion depth measurement. The OCT can deliver structural and depth information of smaller skin lesions (<1 mm), while the US allows to measure the penetration depth of thicker lesions (≥4 mm), and the RS analyzes the chemical composition from a small chosen spot (≤300 μm) that can be used to distinguish between benign and malignant melanoma. The RS and OCT utilize the same scanning and optical setup, allowing for co-localized measurements. The US on the other side is integrated with an acoustical reflector, which enables B-mode measurements on the same position as OCT and RS. The US B-mode scans can be translated across the sample by laterally moving the US transducer, which is made possible by the developed adapter with a flexible membrane. We present the results on custom-made liquid and agar phantoms that show the resolution and depth capabilities of the setup, as well as preliminary ex vivo measurements on mouse models with ∼4.3 mm thick melanoma.
Collapse
Affiliation(s)
- Anatoly Fedorov Kukk
- Hannover Centre for Optical Technologies, Leibniz University of Hannover, Hannover, Germany
| | - Di Wu
- Hannover Centre for Optical Technologies, Leibniz University of Hannover, Hannover, Germany
| | | | | | | | - Bernhard Roth
- Hannover Centre for Optical Technologies, Leibniz University of Hannover, Hannover, Germany
- Cluster of Excellence PhoenixD (Photonics, Optics and Engineering - Innovation Across Disciplines), Hannover, Germany
| |
Collapse
|
33
|
Akolpoglu MB, Alapan Y, Dogan NO, Baltaci SF, Yasa O, Aybar Tural G, Sitti M. Magnetically steerable bacterial microrobots moving in 3D biological matrices for stimuli-responsive cargo delivery. SCIENCE ADVANCES 2022; 8:eabo6163. [PMID: 35857516 PMCID: PMC9286503 DOI: 10.1126/sciadv.abo6163] [Citation(s) in RCA: 77] [Impact Index Per Article: 38.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Bacterial biohybrids, composed of self-propelling bacteria carrying micro/nanoscale materials, can deliver their payload to specific regions under magnetic control, enabling additional frontiers in minimally invasive medicine. However, current bacterial biohybrid designs lack high-throughput and facile construction with favorable cargoes, thus underperforming in terms of propulsion, payload efficiency, tissue penetration, and spatiotemporal operation. Here, we report magnetically controlled bacterial biohybrids for targeted localization and multistimuli-responsive drug release in three-dimensional (3D) biological matrices. Magnetic nanoparticles and nanoliposomes loaded with photothermal agents and chemotherapeutic molecules were integrated onto Escherichia coli with ~90% efficiency. Bacterial biohybrids, outperforming previously reported E. coli-based microrobots, retained their original motility and were able to navigate through biological matrices and colonize tumor spheroids under magnetic fields for on-demand release of the drug molecules by near-infrared stimulus. Our work thus provides a multifunctional microrobotic platform for guided locomotion in 3D biological networks and stimuli-responsive delivery of therapeutics for diverse medical applications.
Collapse
Affiliation(s)
- Mukrime Birgul Akolpoglu
- Physical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569 Stuttgart, Germany
- Institute for Biomedical Engineering, ETH-Zürich, Zürich 8092, Switzerland
| | - Yunus Alapan
- Physical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569 Stuttgart, Germany
| | - Nihal Olcay Dogan
- Physical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569 Stuttgart, Germany
- Institute for Biomedical Engineering, ETH-Zürich, Zürich 8092, Switzerland
| | - Saadet Fatma Baltaci
- Physical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569 Stuttgart, Germany
- Stuttgart Center for Simulation Science (SC SimTech), University of Stuttgart, 70569 Stuttgart, Germany
| | - Oncay Yasa
- Physical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569 Stuttgart, Germany
| | - Gulsen Aybar Tural
- Physical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569 Stuttgart, Germany
- Department of Pharmaceutical Technology, Faculty of Pharmacy, Ege University, 35040 Izmir, Turkey
| | - Metin Sitti
- Physical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569 Stuttgart, Germany
- Institute for Biomedical Engineering, ETH-Zürich, Zürich 8092, Switzerland
- School of Medicine and College of Engineering, Koç University, 34450 Istanbul, Turkey
- Corresponding author.
| |
Collapse
|
34
|
Freymüller C, Ströbl S, Aumiller M, Eisel M, Sroka R, Rühm A. Development of a microstructured tissue phantom with adaptable optical properties for use with microscopes and fluorescence lifetime imaging systems. Lasers Surg Med 2022; 54:1010-1026. [PMID: 35753039 DOI: 10.1002/lsm.23556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Revised: 04/22/2022] [Accepted: 04/24/2022] [Indexed: 11/08/2022]
Abstract
OBJECTIVES For the development and validation of diagnostic procedures based on microscopic methods, knowledge about the imaging depth and achievable resolution in tissue is crucial. This poses the challenge to develop a microscopic artificial phantom focused on the microscopic instead of the macroscopic optical tissue characteristics. METHODS As existing artificial tissue phantoms designed for image forming systems are primarily targeted at wide field applications, they are unsuited for reaching the formulated objective. Therefore, a microscopy- and microendoscopy-suited artificial tissue phantom was developed and characterized. It is based on a microstructured glass surface coated with fluorescent beads at known depths covered by a scattering agent with modifiable optical properties. The phantom was examined with different kinds of microscopy systems in order to characterize its quality and stability and to demonstrate its usefulness for instrument comparison, for example, regarding structural as well as fluorescence lifetime analysis. RESULTS The analysis of the manufactured microstructured glass surfaces showed high regularity in their physical dimensions in accordance with the specifications. Measurements of the optical parameters of the scattering medium were consistent with simulations. The fluorescent beads coating proved to be stable for a respectable period of time (about a week). The developed artificial tissue phantom was successfully used to detect differences in image quality between a research microscope and an endoscopy based system. Plausible causes for the observed differences could be derived based on the well known microstructure of the phantom. CONCLUSIONS The artificial tissue phantom is well suited for the intended use with microscopic and microendoscopic systems. Due to its configurable design, it can be adapted to a wide range of applications. It is especially targeted at the characterization and calibration of clinical imaging systems that often lack extensive positioning capabilities such as an intrinsic z-stage.
Collapse
Affiliation(s)
- Christian Freymüller
- Laser-Forschungslabor, LIFE Center, Department of Urology, University Hospital, LMU Munich, Munich, Germany.,Department of Urology, University Hospital, LMU Munich, Munich, Germany
| | - Stephan Ströbl
- Laser-Forschungslabor, LIFE Center, Department of Urology, University Hospital, LMU Munich, Munich, Germany.,Department of Urology, University Hospital, LMU Munich, Munich, Germany.,Research Center for Microtechnology, FH Vorarlberg, Dornbirn, Vorarlberg, Austria
| | - Maximilian Aumiller
- Laser-Forschungslabor, LIFE Center, Department of Urology, University Hospital, LMU Munich, Munich, Germany.,Department of Urology, University Hospital, LMU Munich, Munich, Germany
| | - Maximilian Eisel
- Laser-Forschungslabor, LIFE Center, Department of Urology, University Hospital, LMU Munich, Munich, Germany.,Department of Urology, University Hospital, LMU Munich, Munich, Germany
| | - Ronald Sroka
- Laser-Forschungslabor, LIFE Center, Department of Urology, University Hospital, LMU Munich, Munich, Germany.,Department of Urology, University Hospital, LMU Munich, Munich, Germany
| | - Adrian Rühm
- Laser-Forschungslabor, LIFE Center, Department of Urology, University Hospital, LMU Munich, Munich, Germany.,Department of Urology, University Hospital, LMU Munich, Munich, Germany
| |
Collapse
|
35
|
Leipheimer J, Balter M, Chen A, Yarmush M. Design and Evaluation of a Handheld Robotic Device for Peripheral Catheterization. J Med Device 2022; 16:021015. [PMID: 35284032 PMCID: PMC8905093 DOI: 10.1115/1.4053688] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 01/14/2022] [Indexed: 08/30/2024] Open
Abstract
Medical robots provide enhanced dexterity, vision, and safety for a broad range of procedures. In this article, we present a handheld, robotic device capable of performing peripheral catheter insertions with high accuracy and repeatability. The device utilizes a combination of ultrasound imaging, miniaturized robotics, and machine learning to safely and efficiently introduce a catheter sheath into a peripheral blood vessel. Here, we present the mechanical design and experimental validation of the device, known as VeniBot. Additionally, we present results on our ultrasound deep learning algorithm for vessel segmentation, and performance on tissue-mimicking phantom models that simulate difficult peripheral catheter placement. Overall, the device achieved first-attempt success rates of 97 ± 4% for vessel punctures and 89 ± 7% for sheath cannulations on the tissue mimicking models (n = 240). The results from these studies demonstrate the viability of a handheld device for performing semi-automated peripheral catheterization. In the future, the use of this device has the potential to improve clinical workflow and reduce patient discomfort by assuring a safe and efficient procedure.
Collapse
Affiliation(s)
| | - Max Balter
- Rutgers University, Piscataway, NJ 08854
| | - Alvin Chen
- Rutgers University, Piscataway, NJ 08854
| | | |
Collapse
|
36
|
Afshari A, Saager RB, Burgos D, Vogt WC, Wang J, Mendoza G, Weininger S, Sung KB, Durkin AJ, Pfefer TJ. Evaluation of the robustness of cerebral oximetry to variations in skin pigmentation using a tissue-simulating phantom. BIOMEDICAL OPTICS EXPRESS 2022; 13:2909-2928. [PMID: 35774336 PMCID: PMC9203096 DOI: 10.1364/boe.454020] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 03/14/2022] [Accepted: 03/28/2022] [Indexed: 05/20/2023]
Abstract
Clinical studies have demonstrated that epidermal pigmentation level can affect cerebral oximetry measurements. To evaluate the robustness of these devices, we have developed a phantom-based test method that includes an epidermis-simulating layer with several melanin concentrations and a 3D-printed cerebrovascular module. Measurements were performed with neonatal, pediatric and adult sensors from two commercial oximeters, where neonatal probes had shorter source-detector separation distances. Referenced blood oxygenation levels ranged from 30 to 90%. Cerebral oximeter outputs exhibited a consistent decrease in saturation level with simulated melanin content; this effect was greatest at low saturation levels, producing a change of up to 15%. Dependence on pigmentation was strongest in a neonatal sensor, possibly due to its high reflectivity. Overall, our findings indicate that a modular channel-array phantom approach can provide a practical tool for assessing the impact of skin pigmentation on cerebral oximeter performance and that modifications to algorithms and/or instrumentation may be needed to mitigate pigmentation bias.
Collapse
Affiliation(s)
- Ali Afshari
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA
| | - Rolf B. Saager
- Linköping Univ., Dept. of Biomedical Engineering, Linköping, Sweden
| | - David Burgos
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA
| | - William C. Vogt
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA
| | - Jianting Wang
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA
| | - Gonzalo Mendoza
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA
| | - Sandy Weininger
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA
| | - Kung-Bin Sung
- National Taiwan University, Graduate Institute of Biomedical Electronics and Bioinformatics, Taipei, Taiwan
| | - Anthony J. Durkin
- Department of Biomedical Engineering, University of California, Irvine, 3120 Natural Sciences II, Irvine, California 92697, USA
- Beckman Laser Institute & Medical Clinic, University of California, Irvine, 1002 Health Sciences Rd. East Irvine, California 92617, USA
| | - T. Joshua Pfefer
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA
| |
Collapse
|
37
|
Amiri SA, Berckel PV, Lai M, Dankelman J, Hendriks BHW. Tissue-mimicking phantom materials with tunable optical properties suitable for assessment of diffuse reflectance spectroscopy during electrosurgery. BIOMEDICAL OPTICS EXPRESS 2022; 13:2616-2643. [PMID: 35774339 PMCID: PMC9203083 DOI: 10.1364/boe.449637] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 02/08/2022] [Accepted: 02/09/2022] [Indexed: 06/15/2023]
Abstract
Emerging intraoperative tumor margin assessment techniques require the development of more complex and reliable organ phantoms to assess the performance of the technique before its translation into the clinic. In this work, electrically conductive tissue-mimicking materials (TMMs) based on fat, water and agar/gelatin were produced with tunable optical properties. The composition of the phantoms allowed for the assessment of tumor margins using diffuse reflectance spectroscopy, as the fat/water ratio served as a discriminating factor between the healthy and malignant tissue. Moreover, the possibility of using polyvinyl alcohol (PVA) or transglutaminase in combination with fat, water and gelatin for developing TMMs was studied. The diffuse spectral response of the developed phantom materials had a good match with the spectral response of porcine muscle and adipose tissue, as well as in vitro human breast tissue. Using the developed recipe, anatomically relevant heterogeneous breast phantoms representing the optical properties of different layers of the human breast were fabricated using 3D-printed molds. These TMMs can be used for further development of phantoms applicable for simulating the realistic breast conserving surgery workflow in order to evaluate the intraoperative optical-based tumor margin assessment techniques during electrosurgery.
Collapse
Affiliation(s)
- Sara Azizian Amiri
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology, The Netherlands
| | - Pieter Van Berckel
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology, The Netherlands
| | - Marco Lai
- Philips Research, IGT & US Devices and Systems Department, Eindhoven, The Netherlands
- Eindhoven University of Technology (TU/e), Eindhoven, The Netherlands
| | - Jenny Dankelman
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology, The Netherlands
| | - Benno H. W. Hendriks
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology, The Netherlands
- Philips Research, IGT & US Devices and Systems Department, Eindhoven, The Netherlands
| |
Collapse
|
38
|
Habibi M, Foroughi S, Karamzadeh V, Packirisamy M. Direct sound printing. Nat Commun 2022; 13:1800. [PMID: 35387993 PMCID: PMC8986813 DOI: 10.1038/s41467-022-29395-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Accepted: 03/09/2022] [Indexed: 11/30/2022] Open
Abstract
Photo- and thermo-activated reactions are dominant in Additive Manufacturing (AM) processes for polymerization or melting/deposition of polymers. However, ultrasound activated sonochemical reactions present a unique way to generate hotspots in cavitation bubbles with extraordinary high temperature and pressure along with high heating and cooling rates which are out of reach for the current AM technologies. Here, we demonstrate 3D printing of structures using acoustic cavitation produced directly by focused ultrasound which creates sonochemical reactions in highly localized cavitation regions. Complex geometries with zero to varying porosities and 280 μm feature size are printed by our method, Direct Sound Printing (DSP), in a heat curing thermoset, Poly(dimethylsiloxane) that cannot be printed directly so far by any method. Sonochemiluminescnce, high speed imaging and process characterization experiments of DSP and potential applications such as remote distance printing are presented. Our method establishes an alternative route in AM using ultrasound as the energy source. Photo- and thermo-activated polymerization and melting processes are dominant in Additive Manufacturing (AM) while ultrasound activated sonochemical reactions have not been explored for AM so far. Here, the authors demonstrate 3D printing of structures using acoustic cavitation produced directly by focused ultrasound which creates sonochemical reactions in highly localized cavitation regions.
Collapse
Affiliation(s)
- Mohsen Habibi
- Optical Bio Microsystems Laboratory, Micro-Nano-Bio Integration Center, Department of Mechanical, Industrial and Aerospace Engineering, Concordia University, Montreal, QC, Canada
| | - Shervin Foroughi
- Optical Bio Microsystems Laboratory, Micro-Nano-Bio Integration Center, Department of Mechanical, Industrial and Aerospace Engineering, Concordia University, Montreal, QC, Canada
| | - Vahid Karamzadeh
- Optical Bio Microsystems Laboratory, Micro-Nano-Bio Integration Center, Department of Mechanical, Industrial and Aerospace Engineering, Concordia University, Montreal, QC, Canada
| | - Muthukumaran Packirisamy
- Optical Bio Microsystems Laboratory, Micro-Nano-Bio Integration Center, Department of Mechanical, Industrial and Aerospace Engineering, Concordia University, Montreal, QC, Canada.
| |
Collapse
|
39
|
Muddassir M, Limbert G, Navarro-Alarcon D. Development of a numerical multi-layer model of skin subjected to pulsed laser irradiation to optimise thermal stimulation in photorejuvenation procedure. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 216:106653. [PMID: 35144148 DOI: 10.1016/j.cmpb.2022.106653] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 12/10/2021] [Accepted: 01/20/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE This paper presents the development of a 3D physics-based numerical model of skin capable of representing the laser-skin photo-thermal interactions occurring in skin photorejuvenation treatment procedures. The aim of this model was to provide a rational and quantitative basis to control and predict temperature distribution within the layered structure of skin. Ultimately, this mathematical and numerical modelling platform will guide the design of an automatic robotic controller to precisely regulate skin temperature at desired depths and for specific durations. METHODS The Pennes bioheat equation was used to account for heat transfer in a 3D multi-layer model of skin. The effects of blood perfusion, skin pigmentation and various convection conditions are also incorporated in the proposed model. The photo-thermal effect due to pulsed laser light on skin is computed using light diffusion theory. The physics-based constitutive model was numerically implemented using a combination of finite volume and finite difference techniques. Direct sensitivity routines were also implemented to assess the influence of constitutive parameters on temperature. A stability analysis of the numerical model was conducted. RESULTS Finally, the numerical model was exploited to assess its ability to predict temperature distribution and thermal damage via a multi-parametric study which accounted for a wide array of biophysical parameters such as light coefficients of absorption for individual skin layers and melanin levels (correlated with ethnicity). It was shown how critical is the link between melanin content, laser light characteristics and potential thermal damage to skin. CONCLUSIONS The developed photo-thermal model of skin-laser interactions paves the way for the design of an automated simulation-driven photorejuvenation robot, thus alleviating the need for inconsistent and error-prone human operators.
Collapse
Affiliation(s)
- Muhammad Muddassir
- Department of Mechanical Engineering, The Hong Kong Polytechnic University (PolyU), KLN, Hong Kong.
| | - Georges Limbert
- Department of Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK; Department of Human Biology, Faculty of Health Sciences, University of Cape Town, Observatory 7935, South Africa.
| | - David Navarro-Alarcon
- Department of Mechanical Engineering, The Hong Kong Polytechnic University (PolyU), KLN, Hong Kong.
| |
Collapse
|
40
|
Bubble Dynamics during Laser Irradiated Thermo-Mechanical Response of Pigmented Skin Phantom. ENERGIES 2022. [DOI: 10.3390/en15062019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/07/2022]
Abstract
During the laser treatment of pigmented dermatosis such as Nevus of Ota, vapor bubbles will be generated by the laser with short pulse width and high energy density. Laser irradiation is efficacious for the clinical treatment of Ota’s Nevus caused by hyperplasia of melanosomes in dermis. Since the mechanism of the laser–melanosome interaction is not yet clear, the clearance rate is generally low and bleeding of irradiated skin frequently occurs. This work conducted a flow visualization experiment to investigate the laser–melanosome interaction mechanism by using high-speed imaging. Pigmented phantom was prepared to simulate the diseased dermis tissue, where agar acted as substrate and synthetic melanin particles was infused as hyperplastic melanosomes. Putting the phantom into water, its thermo-mechanical responses to single-pulse 1064-nm Nd:YAG laser irradiation with energy density of 4–7 J/cm2 and pulse duration of 6 ns were recorded. The results indicated that laser-induced bubble formation caused by the gasification of tissue moisture is the key mechanism of laser–melanosome interaction, and an optimal energy density of 6 J/cm2 is recommended.
Collapse
|
41
|
Hsu HC, Wear KA, Joshua Pfefer T, Vogt WC. Tissue-mimicking phantoms for performance evaluation of photoacoustic microscopy systems. BIOMEDICAL OPTICS EXPRESS 2022; 13:1357-1373. [PMID: 35415004 PMCID: PMC8973174 DOI: 10.1364/boe.445702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 12/19/2021] [Accepted: 01/12/2022] [Indexed: 06/14/2023]
Abstract
Phantom-based performance test methods are critically needed to support development and clinical translation of emerging photoacoustic microscopy (PAM) devices. While phantoms have been recently developed for macroscopic photoacoustic imaging systems, there is an unmet need for well-characterized tissue-mimicking materials (TMMs) and phantoms suitable for evaluating PAM systems. Our objective was to develop and characterize a suitable dermis-mimicking TMM based on polyacrylamide hydrogels and demonstrate its utility for constructing image quality phantoms. TMM formulations were optically characterized over 400-1100 nm using integrating sphere spectrophotometry and acoustically characterized using a pulse through-transmission method over 8-24 MHz with highly confident extrapolation throughout the usable band of the PAM system. This TMM was used to construct a spatial resolution phantom containing gold nanoparticle point targets and a penetration depth phantom containing slanted tungsten filaments and blood-filled tubes. These phantoms were used to characterize performance of a custom-built PAM system. The TMM was found to be broadly tunable and specific formulations were identified to mimic human dermis at an optical wavelength of 570 nm and acoustic frequencies of 10-50 MHz. Imaging results showed that tungsten filaments yielded 1.1-4.2 times greater apparent maximum imaging depth than blood-filled tubes, which may overestimate real-world performance for vascular imaging applications. Nanoparticles were detectable only to depths of 120-200 µm, which may be due to the relatively weaker absorption of single nanoparticles vs. larger targets containing high concentration of hemoglobin. The developed TMMs and phantoms are useful tools to support PAM device characterization and optimization, streamline regulatory decision-making, and accelerate clinical translation.
Collapse
Affiliation(s)
- Hsun-Chia Hsu
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| | - Keith A. Wear
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| | - T. Joshua Pfefer
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| | - William C. Vogt
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| |
Collapse
|
42
|
Jonasson H, Anderson CD, Saager RB. Water and hemoglobin modulated gelatin-based phantoms to spectrally mimic inflamed tissue in the validation of biomedical techniques and the modeling of microdialysis data. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:074712. [PMID: 35106979 PMCID: PMC8804337 DOI: 10.1117/1.jbo.27.7.074712] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 01/10/2022] [Indexed: 06/14/2023]
Abstract
SIGNIFICANCE Tissue simulating phantoms are an important part of validating biomedical optical techniques. Tissue pathology in inflammation and oedema involves changes in both water and hemoglobin fractions. AIM We present a method to create solid gelatin-based phantoms mimicking inflammation and oedema with adjustable water and hemoglobin fractions. APPROACH One store-bought gelatin and one research grade gelatin were evaluated. Different water fractions were obtained by varying the water-to-gelatin ratio. Ferrous stabilized human hemoglobin or whole human blood was added as absorbers, and the stability and characteristics of each were compared. Intralipid® was used as the scatterer. All phantoms were characterized using spatial frequency domain spectroscopy. RESULTS The estimated water fraction varied linearly with expected values (R2 = 0.96 for the store-bought gelatin and R2 = 0.99 for the research grade gelatin). Phantoms including ferrous stabilized hemoglobin stayed stable up to one day but had methemoglobin present at day 0. The phantoms with whole blood remained stable up to 3 days using the store-bought gelatin. CONCLUSIONS A range of physiological relevant water fractions was obtained for both gelatin types, with the stability of the phantoms including hemoglobin differing between the gelatin type and hemoglobin preparation. These low-cost phantoms can incorporate other water-based chromophores and be fabricated as thin sheets to form multilayered structures.
Collapse
Affiliation(s)
- Hanna Jonasson
- Linköping University, Department of Biomedical Engineering, Linköping, Sweden
| | - Chris D. Anderson
- Linköping University, Department of Biomedical and Clinical Sciences, Linköping, Sweden
| | - Rolf B. Saager
- Linköping University, Department of Biomedical Engineering, Linköping, Sweden
| |
Collapse
|
43
|
Laughlin ME, Stephens SE, Hestekin JA, Jensen MO. Development of Custom Wall-Less Cardiovascular Flow Phantoms with Tissue-Mimicking Gel. Cardiovasc Eng Technol 2022; 13:1-13. [PMID: 34080171 PMCID: PMC8888498 DOI: 10.1007/s13239-021-00546-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Accepted: 05/12/2021] [Indexed: 10/26/2022]
Abstract
PURPOSE Flow phantoms are used in experimental settings to aid in the simulation of blood flow. Custom geometries are available, but current phantom materials present issues with degradability and/or mimicking the mechanical properties of human tissue. In this study, a method of fabricating custom wall-less flow phantoms from a tissue-mimicking gel using 3D printed inserts is developed. METHODS A 3D blood vessel geometry example of a bifurcated artery model was 3D printed in polyvinyl alcohol, embedded in tissue-mimicking gel, and subsequently dissolved to create a phantom. Uniaxial compression testing was performed to determine the Young's moduli of the five gel types. Angle-independent, ultrasound-based imaging modalities, Vector Flow Imaging (VFI) and Blood Speckle Imaging (BSI), were utilized for flow visualization of a straight channel phantom. RESULTS A wall-less phantom of the bifurcated artery was fabricated with minimal bubbles and continuous flow demonstrated. Additionally, flow was visualized through a straight channel phantom by VFI and BSI. The available gel types are suitable for mimicking a variety of tissue types, including cardiac tissue and blood vessels. CONCLUSION Custom, tissue-mimicking flow phantoms can be fabricated using the developed methodology and have potential for use in a variety of applications, including ultrasound-based imaging methods. This is the first reported use of BSI with an in vitro flow phantom.
Collapse
Affiliation(s)
- Megan E Laughlin
- Department of Biomedical Engineering, University of Arkansas, John A. White Jr. Engineering Hall, 790 W. Dickson St. #120, Fayetteville, AR, 72701, USA
| | - Sam E Stephens
- Department of Biomedical Engineering, University of Arkansas, John A. White Jr. Engineering Hall, 790 W. Dickson St. #120, Fayetteville, AR, 72701, USA
| | - Jamie A Hestekin
- Department of Chemical Engineering, University of Arkansas, 3202 Bell Engineering Center, Fayetteville, AR, 72701, USA
| | - Morten O Jensen
- Department of Biomedical Engineering, University of Arkansas, John A. White Jr. Engineering Hall, 790 W. Dickson St. #120, Fayetteville, AR, 72701, USA.
| |
Collapse
|
44
|
Chen P, Pollet AMAO, Panfilova A, Zhou M, Turco S, den Toonder JMJ, Mischi M. Acoustic characterization of tissue-mimicking materials for ultrasound perfusion imaging research. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:124-142. [PMID: 34654580 DOI: 10.1016/j.ultrasmedbio.2021.09.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 09/03/2021] [Accepted: 09/03/2021] [Indexed: 06/13/2023]
Abstract
Materials with well-characterized acoustic properties are of great interest for the development of tissue-mimicking phantoms with designed (micro)vasculature networks. These represent a useful means for controlled in-vitro experiments to validate perfusion imaging methods such as Doppler and contrast-enhanced ultrasound (CEUS) imaging. In this work, acoustic properties of seven tissue-mimicking phantom materials at different concentrations of their compounds and five phantom case materials are characterized and compared at room temperature. The goal of this research is to determine the most suitable phantom and case material for ultrasound perfusion imaging experiments. The measurements show a wide range in speed of sound varying from 1057 to 1616 m/s, acoustic impedance varying from 1.09 to 1.71 × 106 kg/m2s, and attenuation coefficients varying from 0.1 to 22.18 dB/cm at frequencies varying from 1 MHz to 6 MHz for different phantom materials. The nonlinearity parameter B/A varies from 6.1 to 12.3 for most phantom materials. This work also reports the speed of sound, acoustic impedance and attenuation coefficient for case materials. According to our results, polyacrylamide (PAA) and polymethylpentene (TPX) are the optimal materials for phantoms and their cases, respectively. To demonstrate the performance of the optimal materials, we performed power Doppler ultrasound imaging of a perfusable phantom, and CEUS imaging of that phantom and a perfusion system. The obtained results can assist researchers in the selection of the most suited materials for in-vitro studies with ultrasound imaging.
Collapse
Affiliation(s)
- Peiran Chen
- Dept. Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands.
| | - Andreas M A O Pollet
- Dept. Mechanical Engineering, Institute for Complex Molecular Systems, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Anastasiia Panfilova
- Dept. Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Meiyi Zhou
- Dept. Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Simona Turco
- Dept. Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Jaap M J den Toonder
- Dept. Mechanical Engineering, Institute for Complex Molecular Systems, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Massimo Mischi
- Dept. Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| |
Collapse
|
45
|
Song N, Xie P, Shen W, Oh H, Zhang Y, Vitale F, Javanmard M, Allen MG. A microwell-based impedance sensor on an insertable microneedle for real-time in vivo cytokine detection. MICROSYSTEMS & NANOENGINEERING 2021; 7:96. [PMID: 34900330 PMCID: PMC8626445 DOI: 10.1038/s41378-021-00297-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 05/17/2021] [Accepted: 06/09/2021] [Indexed: 06/01/2023]
Abstract
Impedance-based protein detection sensors for point-of-care diagnostics require quantitative specificity, as well as rapid or real-time operation. Furthermore, microfabrication of these sensors can lead to the formation of factors suitable for in vivo operation. Herein, we present microfabricated needle-shaped microwell impedance sensors for rapid-sample-to-answer, label-free detection of cytokines, and other biomarkers. The microneedle form factor allows sensors to be utilized in transcutaneous or transvascular sensing applications. In vitro, experimental characterization confirmed sensor specificity and sensitivity to multiple proteins of interest. Mechanical characterization demonstrated sufficient microneedle robustness for transcutaneous insertion, as well as preserved sensor function postinsertion. We further utilized these sensors to carry out real-time in vivo quantification of human interleukin 8 (hIL8) concentration levels in the blood of transgenic mice that endogenously express hIL8. To assess sensor functionality, hIL8 concentration levels in serum samples from the same mice were quantified by ELISA. Excellent agreement between real-time in vivo sensor readings in blood and subsequent ELISA serum assays was observed over multiple transgenic mice expressing hIL8 concentrations from 62 pg/mL to 539 ng/mL.
Collapse
Affiliation(s)
- Naixin Song
- Department of Electrical and Systems Engineering, University of Pennsylvania, Philadelphia, PA USA
| | - Pengfei Xie
- Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ USA
| | - Wen Shen
- Department of Electrical and Systems Engineering, University of Pennsylvania, Philadelphia, PA USA
| | - Hanju Oh
- Department of Electrical and Systems Engineering, University of Pennsylvania, Philadelphia, PA USA
| | - Yejia Zhang
- Department of Physical Medicine and Rehabilitation, University of Pennsylvania, Philadelphia, PA USA
- Department of Orthopedic Surgery, University of Pennsylvania, Philadelphia, PA USA
- Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, PA USA
| | - Flavia Vitale
- Department of Physical Medicine and Rehabilitation, University of Pennsylvania, Philadelphia, PA USA
- Department of Orthopedic Surgery, University of Pennsylvania, Philadelphia, PA USA
- Department of Bioengineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, PA USA
- Department of Neurology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA USA
| | - Mehdi Javanmard
- Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ USA
| | - Mark G. Allen
- Department of Electrical and Systems Engineering, University of Pennsylvania, Philadelphia, PA USA
| |
Collapse
|
46
|
Zhu M, Shen Y, Chiluisa AJ, Song J, Fichera L, Liu Y. Optical Fiber Coupling System for Steerable Endoscopic Instruments. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:4871-4874. [PMID: 34892300 PMCID: PMC9234471 DOI: 10.1109/embc46164.2021.9629658] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
In this paper, we present an optical coupling system that couples light from an Endostat fiber in a commercial laser surgical system into a smaller multimode fiber, in order to enable endoscopic probe steering in a tightly confined space. Unlike the Endostat fibers, which have a minimum bending radius of 12 mm due to the large diameter, our work allows the laser to be delivered by smaller fibers that can be readily bent at a 6-mm bending radius by a distal steerable mechanism. Such a readily achievable sharp bending facilitates the surgical laser to access hard-to-reach anatomies. We experimentally achieved an optical power coupling efficiency of ≈ 50%. Tissue ablation experiments were performed to prove the feasibility and potential of our light coupling system in clinical laser surgeries, as well as other optical fiber-based endoscopic medical devices.Clinical Relevance- Optical fibers are commonly used in laser-based surgical systems. The optical coupling system in this paper enables the laser to be delivered by small fibers, helps realize the fiber bending and steering, and hence allows the laser treatments of previous inaccessible anatomies.
Collapse
|
47
|
In-silico investigation towards the non-invasive optical detection of blood lactate. Sci Rep 2021; 11:14274. [PMID: 34253775 PMCID: PMC8275594 DOI: 10.1038/s41598-021-92803-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Accepted: 06/08/2021] [Indexed: 02/06/2023] Open
Abstract
This paper uses Monte Carlo simulations to investigate the interaction of short-wave infrared (SWIR) light with vascular tissue as a step toward the development of a non-invasive optical sensor for measuring blood lactate in humans. The primary focus of this work was to determine the optimal source-detector separation, penetration depth of light at SWIR wavelengths in tissue, and the optimal light power required for reliable detection of lactate. The investigation also focused on determining the non-linear variations in absorbance of lactate at a few select SWIR wavelengths. SWIR photons only penetrated 1.3 mm and did not travel beyond the hypodermal fat layer. The maximum output power was only 2.51% of the input power, demonstrating the need for a highly sensitive detection system. Simulations optimized a source-detector separation of 1 mm at 1684 nm for accurate measurement of lactate in blood.
Collapse
|
48
|
Dervisevic M, Alba M, Adams TE, Prieto-Simon B, Voelcker NH. Electrochemical immunosensor for breast cancer biomarker detection using high-density silicon microneedle array. Biosens Bioelectron 2021; 192:113496. [PMID: 34274623 DOI: 10.1016/j.bios.2021.113496] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Accepted: 07/08/2021] [Indexed: 11/16/2022]
Abstract
Electrochemical devices for transdermal monitoring of key biomarkers are the potential next frontier of wearable technologies for point-of-care disease diagnosis, including Cancer in which Cancer is the leading cause of death worldwide with estimated 10 million deaths in 2018 according to the World Health Organization and breast cancer is one of the five most common causes of cancer death with over two million cases recorded in 2018. Early diagnosis and prognosis based on monitoring of breast cancer biomarkers is of high importance. In this work, high-density gold coated silicon microneedle arrays (Au-Si-MNA) were simultaneously used as biomarker extraction platform and electrochemical transducer, enabling the selective immunocapture of epidermal growth factor receptor 2 (ErbB2), a key breast cancer biomarker, and its subsequent quantification. The analytical performance of the device was tested in artificial interstitial fluid exhibiting a linear response over a wide concentration range from 10 to 250 ng/mL, with a detection limit of 4.8 ng/mL below the biomarker levels expected in breast cancer patients. As a proof of concept, the immunosensor demonstrated its ability to successfully extract ErbB2 from a phantom gel mimicking the epidermis and dermis layers, and subsequently quantify it showing a linear range from 50 to 250 ng/mL and a detection limit of 25 ng/mL. The uniqueness of this sensing platform combining direct transdermal biomarker extraction and quantification opens up new avenues towards the development of high performing wearable point-of-care devices.
Collapse
Affiliation(s)
- Muamer Dervisevic
- Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia
| | - Maria Alba
- Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia; Commonwealth Scientific and Industrial Research Organization (CSIRO), Clayton, Victoria, 3168, Australia
| | - Timothy E Adams
- Commonwealth Scientific and Industrial Research Organization (CSIRO), Clayton, Victoria, 3168, Australia
| | - Beatriz Prieto-Simon
- Department of Electronic Engineering, Universitat Rovira i Virgili, 43007, Tarragona, Spain; ICREA, Pg. Lluís Companys 23, 08010, Barcelona, Spain
| | - Nicolas H Voelcker
- Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia; Commonwealth Scientific and Industrial Research Organization (CSIRO), Clayton, Victoria, 3168, Australia; Melbourne Centre for Nanofabrication, Victorian Node of the Australian National Fabrication Facility, Clayton, Victoria, 3168, Australia; Materials Science and Engineering, Monash University, Clayton, Victoria, 3168, Australia.
| |
Collapse
|
49
|
Hinricher N, Pawelzik L, Backhaus C. Investigation of Impulse Oscillometry for the Detection of Extravasations using Design of Experiments and an Infusion Simulator. Med Eng Phys 2021; 92:33-39. [PMID: 34167709 DOI: 10.1016/j.medengphy.2021.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Revised: 03/17/2021] [Accepted: 04/07/2021] [Indexed: 11/25/2022]
Abstract
Extravasation is a phenomenon that occurs when the infusion solution misses the vein and enters the surrounding tissue. We developed a sensor prototype utilising impulse oscillometry to detect extravasations at an early stage. A hydraulic impulse is injected into the infusion line to observe and analyse its progress. The aim of this study was to determine the tissue parameters that might influence the sensor measurement signal and signal changes during extravasation. We developed a simulator that simulates infusions and extravasations to test the prototype. Tissue-specific parameters can be adjusted independently. The effects of the tissue parameters, including blood pressure, blood flow, blood density, blood viscosity, vein diameter, venous wall thickness, and tissue modulus of elasticity, were investigated using the design of experiments method. The parameter values were varied between two levels and tested across 16 experiments. Blood pressure, blood viscosity, vein diameter, and venous compliance demonstrated the greatest impact on the sensor signal (p < .001). The other parameters showed negligible effects. Significant differences (p = .006) in the pressure signal of the sensor could be observed when the catheter changed from the venous position to the extravasal position.
Collapse
Affiliation(s)
- N Hinricher
- Münster University of Applied Sciences, Centre for Ergonomics and Medical Engineering, Bürgerkamp 3, 48565 Steinfurt, Germany
| | - L Pawelzik
- Münster University of Applied Sciences, Centre for Ergonomics and Medical Engineering, Bürgerkamp 3, 48565 Steinfurt, Germany.
| | - C Backhaus
- Münster University of Applied Sciences, Centre for Ergonomics and Medical Engineering, Bürgerkamp 3, 48565 Steinfurt, Germany
| |
Collapse
|
50
|
Long H, Chen B, Li W, Xian Y, Peng Z. Blood glucose detection based on Teager-Kaiser main energy of photoacoustic signal. Comput Biol Med 2021; 134:104552. [PMID: 34144363 DOI: 10.1016/j.compbiomed.2021.104552] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 06/02/2021] [Accepted: 06/02/2021] [Indexed: 11/27/2022]
Abstract
Real-time blood glucose detection is an essential tool for diabetes monitoring. Non-invasive blood glucose detection technology is one of the current research hotspots in this field. Previous research mainly focused on improving the system's detection capability to obtain signals with low signal-to-noise ratio and high quality, and simple methods are often used in signal processing. Moreover, photoacoustic signal simulation also simplifies the influence of the transmission medium on the signal. In the present study, we built a new simulation model which considers human skin, blood, and the detector's limitations, to obtain a more practical photoacoustic signal. We then proposed a blood glucose detection algorithm based on Teager-Kaiser main energy (TKME) to overcome noise and medium interference and achieve a high detection accuracy at low SNR. Finally, the simulation and actual data were utilised during the experiment, and the detection error was 15 mg/dL (SNR = 10 dB).
Collapse
Affiliation(s)
- Hongfeng Long
- School of Information and Communication Engineering, University of Electronic Science and Technology of China, Chengdu, 610054, China; Laboratory of Imaging Detection and Intelligent Perception University of Electronic Science and Technology of China, 610054, Chengdu, China
| | - Bingzhang Chen
- School of Information and Communication Engineering, University of Electronic Science and Technology of China, Chengdu, 610054, China; Laboratory of Imaging Detection and Intelligent Perception University of Electronic Science and Technology of China, 610054, Chengdu, China.
| | - Wei Li
- School of Information and Communication Engineering, University of Electronic Science and Technology of China, Chengdu, 610054, China; Laboratory of Imaging Detection and Intelligent Perception University of Electronic Science and Technology of China, 610054, Chengdu, China
| | - Yongli Xian
- School of Information and Communication Engineering, University of Electronic Science and Technology of China, Chengdu, 610054, China; School of Electronic Engineering and Electronic Information, Xihua University, Chengdu, 610039, China
| | - Zhenming Peng
- School of Information and Communication Engineering, University of Electronic Science and Technology of China, Chengdu, 610054, China; Laboratory of Imaging Detection and Intelligent Perception University of Electronic Science and Technology of China, 610054, Chengdu, China.
| |
Collapse
|