51
|
Gomez-Gonzalez E, Muñoz O, Gomez-Martin JC, Aceituno-Castro J, Fernandez-Muñoz B, Navas-Garcia JM, Barriga-Rivera A, Fernandez-Lizaranzu I, Munoz-Gonzalez FJ, Parrilla-Giraldez R, Requena-Lancharro D, Gil-Gamboa P, Ramos JL, Rosell-Valle C, Gomez-Gonzalez C, Martin-Lopez M, Relimpio-Lopez MI, Perales-Esteve MA, Puppo-Moreno A, Garcia-Cozar FJ, Olvera-Collantes L, de Los Santos-Trigo S, Gomez E, Sanchez-Pernaute R, Padillo-Ruiz J, Marquez-Rivas J. Polarimetric imaging for the detection of synthetic models of SARS-CoV-2: A proof of concept. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER 2023; 302:108567. [PMID: 36945203 PMCID: PMC9987604 DOI: 10.1016/j.jqsrt.2023.108567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Revised: 03/04/2023] [Accepted: 03/04/2023] [Indexed: 06/18/2023]
Abstract
Objective To conduct a proof-of-concept study of the detection of two synthetic models of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using polarimetric imaging. Approach Two SARS-CoV-2 models were prepared as engineered lentiviruses pseudotyped with the G protein of the vesicular stomatitis virus, and with the characteristic Spike protein of SARS-CoV-2. Samples were prepared in two biofluids (saline solution and artificial saliva), in four concentrations, and deposited as 5-µL droplets on a supporting plate. The angles of maximal degree of linear polarization (DLP) of light diffusely scattered from dry residues were determined using Mueller polarimetry from87 samples at 405 nm and 514 nm. A polarimetric camera was used for imaging several samples under 380-420 nm illumination at angles similar to those of maximal DLP. Per-pixel image analysis included quantification and combination of polarization feature descriptors in 475 samples. Main results The angles (from sample surface) of maximal DLP were 3° for 405 nm and 6° for 514 nm. Similar viral particles that differed only in the characteristic spike protein of the SARS-CoV-2, their corresponding negative controls, fluids, and the sample holder were discerned at 10-degree and 15-degree configurations. Significance Polarimetric imaging in the visible spectrum may help improve fast, non-contact detection and identification of viral particles, and/or other microbes such as tuberculosis, in multiple dry fluid samples simultaneously, particularly when combined with other imaging modalities. Further analysis including realistic concentrations of real SARS-CoV-2 viral particles in relevant human fluids is required. Polarimetric imaging under visible light may contribute to a fast, cost-effective screening of SARS-CoV-2 and other pathogens when combined with other imaging modalities.
Collapse
Affiliation(s)
- Emilio Gomez-Gonzalez
- Group of Interdisciplinary Physics, Department of Applied Physics III at the ETSI Engineering School, Universidad de Sevilla, Seville 41092, Spain
- Institute of Biomedicine of Seville, Spain
| | - Olga Muñoz
- Cosmic Dust Laboratory, Instituto de Astrofísica de Andalucía, CSIC, Granada 18008, Spain
| | | | - Jesus Aceituno-Castro
- Cosmic Dust Laboratory, Instituto de Astrofísica de Andalucía, CSIC, Granada 18008, Spain
- Centro Astronomico Hispano Alemán, Almeria 04550, Spain
| | - Beatriz Fernandez-Muñoz
- Unidad de Producción y Reprogramación Celular, Red Andaluza de Diseño y Traslación de Terapias Avanzadas, Fundacion Publica Andaluza Progreso y Salud, Sevilla 41092, Spain
| | | | - Alejandro Barriga-Rivera
- Group of Interdisciplinary Physics, Department of Applied Physics III at the ETSI Engineering School, Universidad de Sevilla, Seville 41092, Spain
- School of Biomedical Engineering, The University of Sydney, NSW 2006, Australia
| | - Isabel Fernandez-Lizaranzu
- Group of Interdisciplinary Physics, Department of Applied Physics III at the ETSI Engineering School, Universidad de Sevilla, Seville 41092, Spain
- Institute of Biomedicine of Seville, Spain
| | - Francisco Javier Munoz-Gonzalez
- Group of Interdisciplinary Physics, Department of Applied Physics III at the ETSI Engineering School, Universidad de Sevilla, Seville 41092, Spain
| | | | - Desiree Requena-Lancharro
- Group of Interdisciplinary Physics, Department of Applied Physics III at the ETSI Engineering School, Universidad de Sevilla, Seville 41092, Spain
| | - Pedro Gil-Gamboa
- Group of Interdisciplinary Physics, Department of Applied Physics III at the ETSI Engineering School, Universidad de Sevilla, Seville 41092, Spain
| | - José Luis Ramos
- Cosmic Dust Laboratory, Instituto de Astrofísica de Andalucía, CSIC, Granada 18008, Spain
| | - Cristina Rosell-Valle
- Unidad de Producción y Reprogramación Celular, Red Andaluza de Diseño y Traslación de Terapias Avanzadas, Fundacion Publica Andaluza Progreso y Salud, Sevilla 41092, Spain
| | - Carmen Gomez-Gonzalez
- Service of Intensive Care, University Hospital 'Virgen del Rocio', Sevilla 41013, Spain
| | - Maria Martin-Lopez
- Unidad de Producción y Reprogramación Celular, Red Andaluza de Diseño y Traslación de Terapias Avanzadas, Fundacion Publica Andaluza Progreso y Salud, Sevilla 41092, Spain
| | - Maria Isabel Relimpio-Lopez
- Department of General Surgery, College of Medicine, Universidad de Sevilla, Seville 41009, Spain
- Department of Ophthalmology, University Hospital 'Virgen Macarena', Sevilla 41009, Spain
- OftaRed, Institute of Health 'Carlos III', Madrid 28029, Spain
| | - Manuel A Perales-Esteve
- Group of Interdisciplinary Physics, Department of Applied Physics III at the ETSI Engineering School, Universidad de Sevilla, Seville 41092, Spain
- Department of Electronic Engineering at the ETSI Engineering School, Universidad de Sevilla, Seville 41092, Spain
| | - Antonio Puppo-Moreno
- Institute of Biomedicine of Seville, Spain
- Service of Intensive Care, University Hospital 'Virgen del Rocio', Sevilla 41013, Spain
| | - Francisco Jose Garcia-Cozar
- Department of Biomedicine, Biotechnology and Public Health, University of Cadiz, Cadiz 11003, Spain
- Instituto de Investigación e Innovación Biomedica de Cádiz (INIBICA), Cadiz 11009, Spain
| | - Lucia Olvera-Collantes
- Department of Biomedicine, Biotechnology and Public Health, University of Cadiz, Cadiz 11003, Spain
- Instituto de Investigación e Innovación Biomedica de Cádiz (INIBICA), Cadiz 11009, Spain
| | | | - Emilia Gomez
- Joint Research Centre, European Commission, Sevilla 41092, Spain
| | - Rosario Sanchez-Pernaute
- Unidad de Producción y Reprogramación Celular, Red Andaluza de Diseño y Traslación de Terapias Avanzadas, Fundacion Publica Andaluza Progreso y Salud, Sevilla 41092, Spain
| | | | - Javier Marquez-Rivas
- Group of Interdisciplinary Physics, Department of Applied Physics III at the ETSI Engineering School, Universidad de Sevilla, Seville 41092, Spain
- Institute of Biomedicine of Seville, Spain
- Service of Neurosurgery, University Hospital 'Virgen del Rocío', Sevilla 41013, Spain
| |
Collapse
|
52
|
Ghosh R, Joung HA, Goncharov A, Palanisamy B, Ngo K, Pejcinovic K, Krockenberger N, Horn EJ, Garner OB, Ghazal E, O’Kula A, Arnaboldi PM, Dattwyler RJ, Ozcan A, Di Carlo D. Single-tier point-of-care serodiagnosis of Lyme disease. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.06.14.544508. [PMID: 37398357 PMCID: PMC10312703 DOI: 10.1101/2023.06.14.544508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/04/2023]
Abstract
Point-of-care (POC) serological testing provides actionable information for several difficult to diagnose illnesses, empowering distributed health systems. Accessible and adaptable diagnostic platforms that can assay the repertoire of antibodies formed against pathogens are essential to drive early detection and improve patient outcomes. Here, we report a POC serologic test for Lyme disease (LD), leveraging synthetic peptides tuned to be highly specific to the LD antibody repertoire across patients and compatible with a paper-based platform for rapid, reliable, and cost-effective diagnosis. A subset of antigenic epitopes conserved across Borrelia burgdorferi genospecies and targeted by IgG and IgM antibodies, were selected based on their seroreactivity to develop a multiplexed panel for a single-step measurement of combined IgM and IgG antibodies from LD patient sera. Multiple peptide epitopes, when combined synergistically using a machine learning-based diagnostic model, yielded a high sensitivity without any loss in specificity. We blindly tested the platform with samples from the U.S. Centers for Disease Control & Prevention (CDC) LD repository and achieved a sensitivity and specificity matching the lab-based two-tier results with a single POC test, correctly discriminating cross-reactive look-alike diseases. This computational LD diagnostic test can potentially replace the cumbersome two-tier testing paradigm, improving diagnosis and enabling earlier effective treatment of LD patients while also facilitating immune monitoring and surveillance of the disease in the community.
Collapse
Affiliation(s)
- Rajesh Ghosh
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
| | - Hyou-Arm Joung
- Electrical & Computer Engineering Department, University of California, Los Angeles, CA 90095 USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095 USA
| | - Artem Goncharov
- Electrical & Computer Engineering Department, University of California, Los Angeles, CA 90095 USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095 USA
| | - Barath Palanisamy
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
| | - Kevin Ngo
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
| | - Katarina Pejcinovic
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
| | | | | | - Omai B. Garner
- Department of Pathology and Laboratory Medicine, University of California, Los Angeles, CA 90095 USA
| | - Ezdehar Ghazal
- Department of Pathology, Microbiology, and Immunology, New York Medical College, Valhalla, New York 10595, United States
| | - Andrew O’Kula
- Department of Pathology, Microbiology, and Immunology, New York Medical College, Valhalla, New York 10595, United States
| | - Paul M. Arnaboldi
- Department of Pathology, Microbiology, and Immunology, New York Medical College, Valhalla, New York 10595, United States
- Biopeptides, Corp. East Setauket, NY 11733
| | - Raymond J. Dattwyler
- Department of Pathology, Microbiology, and Immunology, New York Medical College, Valhalla, New York 10595, United States
- Biopeptides, Corp. East Setauket, NY 11733
| | - Aydogan Ozcan
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
- Electrical & Computer Engineering Department, University of California, Los Angeles, CA 90095 USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095 USA
- Department of Surgery, University of California, Los Angeles, CA 90095 USA
| | - Dino Di Carlo
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095 USA
- Department of Mechanical Engineering, University of California, Los Angeles, CA 90095 USA
| |
Collapse
|
53
|
Nath P, Mahtaba KR, Ray A. Fluorescence-Based Portable Assays for Detection of Biological and Chemical Analytes. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23115053. [PMID: 37299780 DOI: 10.3390/s23115053] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 05/16/2023] [Accepted: 05/22/2023] [Indexed: 06/12/2023]
Abstract
Fluorescence-based detection techniques are part of an ever-expanding field and are widely used in biomedical and environmental research as a biosensing tool. These techniques have high sensitivity, selectivity, and a short response time, making them a valuable tool for developing bio-chemical assays. The endpoint of these assays is defined by changes in fluorescence signal, in terms of its intensity, lifetime, and/or shift in spectrum, which is monitored using readout devices such as microscopes, fluorometers, and cytometers. However, these devices are often bulky, expensive, and require supervision to operate, which makes them inaccessible in resource-limited settings. To address these issues, significant effort has been directed towards integrating fluorescence-based assays into miniature platforms based on papers, hydrogels, and microfluidic devices, and to couple these assays with portable readout devices like smartphones and wearable optical sensors, thereby enabling point-of-care detection of bio-chemical analytes. This review highlights some of the recently developed portable fluorescence-based assays by discussing the design of fluorescent sensor molecules, their sensing strategy, and the fabrication of point-of-care devices.
Collapse
Affiliation(s)
- Peuli Nath
- Department of Physics and Astronomy, University of Toledo, Toledo, OH 43606, USA
| | - Kazi Ridita Mahtaba
- Department of Physics and Astronomy, University of Toledo, Toledo, OH 43606, USA
| | - Aniruddha Ray
- Department of Physics and Astronomy, University of Toledo, Toledo, OH 43606, USA
| |
Collapse
|
54
|
Principi N, Autore G, Ramundo G, Esposito S. Epidemiology of Respiratory Infections during the COVID-19 Pandemic. Viruses 2023; 15:1160. [PMID: 37243246 PMCID: PMC10224029 DOI: 10.3390/v15051160] [Citation(s) in RCA: 75] [Impact Index Per Article: 37.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 05/04/2023] [Accepted: 05/08/2023] [Indexed: 05/28/2023] Open
Abstract
To face the COVID-19 outbreak, a wide range of non-pharmaceutical interventions (NPIs) aimed at limiting the spread of the virus in communities, such as mask-wearing, hand hygiene, social distancing, travel restrictions, and school closures, were introduced in most countries. Thereafter, a significant reduction of new asymptomatic and symptomatic COVID-19 cases occurred, although there were differences between countries according to the type and duration of the NPIs. In addition, the COVID-19 pandemic has been accompanied by significant variations in the global incidence of diseases due to the most common non-SARS-CoV-2 respiratory viruses and some bacteria. In this narrative review, the epidemiology of the most common non-SARS-CoV-2 respiratory infections during the COVID-19 pandemic is detailed. Moreover, factors that could have had a role in modifying the traditional circulation of respiratory pathogens are discussed. A literature analysis shows that NPIs were the most important cause of the general reduction in the incidence of influenza and respiratory syncytial virus infection in the first year of the pandemic, although the different sensitivity of each virus to NPIs, the type and duration of measures used, as well as the interference among viruses may have played a role in modulating viral circulation. Reasons for the increase in the incidences of Streptococcus pneumoniae and group A Streptococcus infections seem strictly linked to immunity debt and the role played by NPIs in reducing viral infections and limiting bacterial superimposed infections. These results highlight the importance of NPIs during pandemics, the need to monitor the circulation of infectious agents that cause diseases similar to those caused by pandemic agents, and the need to make efforts to improve coverage with available vaccines.
Collapse
Affiliation(s)
| | - Giovanni Autore
- Pediatric Clinic, Pietro Barilla Children’s Hospital, Department of Medicine and Surgery, University Hospital of Parma, 43126 Parma, Italy; (G.A.)
| | - Greta Ramundo
- Pediatric Clinic, Pietro Barilla Children’s Hospital, Department of Medicine and Surgery, University Hospital of Parma, 43126 Parma, Italy; (G.A.)
| | - Susanna Esposito
- Pediatric Clinic, Pietro Barilla Children’s Hospital, Department of Medicine and Surgery, University Hospital of Parma, 43126 Parma, Italy; (G.A.)
| |
Collapse
|
55
|
Hou F, Sun S, Abdullah SW, Tang Y, Li X, Guo H. The application of nanoparticles in point-of-care testing (POCT) immunoassays. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:2154-2180. [PMID: 37114768 DOI: 10.1039/d3ay00182b] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
The Covid-19 pandemic has led to greater recognition of the importance of the fast and timely detection of pathogens. Recent advances in point-of-care testing (POCT) technology have shown promising results for rapid diagnosis. Immunoassays are among the most extensive POCT assays, in which specific labels are used to indicate and amplify the immune signal. Nanoparticles (NPs) are above the rest because of their versatile properties. Much work has been devoted to NPs to find more efficient immunoassays. Herein, we comprehensively describe NP-based immunoassays with a focus on particle species and their specific applications. This review describes immunoassays along with key concepts surrounding their preparation and bioconjugation to show their defining role in immunosensors. The specific mechanisms, microfluidic immunoassays, electrochemical immunoassays (ELCAs), immunochromatographic assays (ICAs), enzyme-linked immunosorbent assays (ELISA), and microarrays are covered herein. For each mechanism, a working explanation of the appropriate background theory and formalism is articulated before examining the biosensing and related point-of-care (POC) utility. Given their maturity, some specific applications using different nanomaterials are discussed in more detail. Finally, we outline future challenges and perspectives to give a brief guideline for the development of appropriate platforms.
Collapse
Affiliation(s)
- Fengping Hou
- State Key Laboratory of Veterinary Etiological Biology, OIE/China National Foot-and-Mouth Disease Reference Laboratory, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Xujiaping 1, Lanzhou 730046, Gansu, P. R. China.
- Lanzhou Institute of Biological Products Co., Ltd (LIBP), Subsidiary Company of China National Biotec Group Company Limited (CNBG), 730046 Lanzhou, China.
| | - Shiqi Sun
- State Key Laboratory of Veterinary Etiological Biology, OIE/China National Foot-and-Mouth Disease Reference Laboratory, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Xujiaping 1, Lanzhou 730046, Gansu, P. R. China.
| | - Sahibzada Waheed Abdullah
- State Key Laboratory of Veterinary Etiological Biology, OIE/China National Foot-and-Mouth Disease Reference Laboratory, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Xujiaping 1, Lanzhou 730046, Gansu, P. R. China.
| | - Yu Tang
- State Key Laboratory of Applied Organic Chemistry, Key Laboratory of Nonferrous Metal Chemistry and Resources Utilization of Gansu Province, College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000, Gansu, P. R. China
| | - Xiongxiong Li
- Lanzhou Institute of Biological Products Co., Ltd (LIBP), Subsidiary Company of China National Biotec Group Company Limited (CNBG), 730046 Lanzhou, China.
| | - Huichen Guo
- State Key Laboratory of Veterinary Etiological Biology, OIE/China National Foot-and-Mouth Disease Reference Laboratory, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Xujiaping 1, Lanzhou 730046, Gansu, P. R. China.
- State Key Laboratory for Animal Disease Control and Prevention, College of Veterinary Medicine, Lanzhou University, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730000, P. R. China
| |
Collapse
|
56
|
Huang S, An Y, Xi B, Gong X, Chen Z, Shao S, Ge S, Zhang J, Zhang D, Xia N. Ultra-fast, sensitive and low-cost real-time PCR system for nucleic acid detection. LAB ON A CHIP 2023; 23:2611-2622. [PMID: 37158116 DOI: 10.1039/d3lc00174a] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Nucleic acid detection directly identifies the presence of pathogenic microorganisms and has various advantages, such as high sensitivity, commendable specificity and a short window period, and has been widely used in many fields, such as early tumor screening, prenatal diagnosis and infectious disease detection. Real-time PCR (polymerase chain reaction) is the most commonly used method for nucleic acid detection in clinical practice, but it always takes about 1-3 hours, severely limiting its application in particular scenarios such as emergency testing, large-scale testing and on-site testing. To solve the time-consuming problem, a real-time PCR system based on multiple temperature zones was proposed, which realized the speed of temperature change of biological reagents from 2-4 °C s-1 to 13.33 °C s-1. The system integrates the advantages of fixed microchamber-type and microchannel-type amplification systems, including a microfluidic chip capable of fast heat transfer and a real-time PCR device with a temperature control strategy based on the temperature difference. The detection of HCMV biological samples using the real-time PCR system in this research took only 15 min, which was 75% shorter compared to the commercial qPCR instrument such as BIO-RAD, and the detection sensitivity remained essentially the same. The system could complete nucleic acid detection within 9 min under extreme conditions, characterized by fast detection speed and high sensitivity, providing a promising solution for ultra-fast nucleic acid detection.
Collapse
Affiliation(s)
- Shaolei Huang
- School of Public Health, Xiamen University, Fujian, China.
- Discipline of Intelligent Instrument and Equipment, Xiamen University, Fujian, China
- National Institute of Diagnostics and Vaccine Development in Infectious Diseases (Xiamen University), Fujian, China
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, Fujian, China
| | - Yiquan An
- School of Public Health, Xiamen University, Fujian, China.
- National Institute of Diagnostics and Vaccine Development in Infectious Diseases (Xiamen University), Fujian, China
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, Fujian, China
| | - Bangchao Xi
- School of Public Health, Xiamen University, Fujian, China.
- National Institute of Diagnostics and Vaccine Development in Infectious Diseases (Xiamen University), Fujian, China
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, Fujian, China
| | - Xianglian Gong
- School of Public Health, Xiamen University, Fujian, China.
- National Institute of Diagnostics and Vaccine Development in Infectious Diseases (Xiamen University), Fujian, China
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, Fujian, China
| | - Zhongfu Chen
- School of Public Health, Xiamen University, Fujian, China.
- National Institute of Diagnostics and Vaccine Development in Infectious Diseases (Xiamen University), Fujian, China
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, Fujian, China
| | - Shan Shao
- School of Public Health, Xiamen University, Fujian, China.
- National Institute of Diagnostics and Vaccine Development in Infectious Diseases (Xiamen University), Fujian, China
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, Fujian, China
| | - Shengxiang Ge
- School of Public Health, Xiamen University, Fujian, China.
- National Institute of Diagnostics and Vaccine Development in Infectious Diseases (Xiamen University), Fujian, China
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, Fujian, China
| | - Jun Zhang
- School of Public Health, Xiamen University, Fujian, China.
- National Institute of Diagnostics and Vaccine Development in Infectious Diseases (Xiamen University), Fujian, China
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, Fujian, China
| | - Dongxu Zhang
- School of Public Health, Xiamen University, Fujian, China.
- Discipline of Intelligent Instrument and Equipment, Xiamen University, Fujian, China
- National Institute of Diagnostics and Vaccine Development in Infectious Diseases (Xiamen University), Fujian, China
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, Fujian, China
| | - Ningshao Xia
- School of Public Health, Xiamen University, Fujian, China.
- Discipline of Intelligent Instrument and Equipment, Xiamen University, Fujian, China
- National Institute of Diagnostics and Vaccine Development in Infectious Diseases (Xiamen University), Fujian, China
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, Fujian, China
| |
Collapse
|
57
|
Sagoe KO, Kyama MC, Maina N, Kamita M, Njokah M, Thiong'o K, Kanoi BN, Wandera EA, Ndegwa D, Kinyua DM, Gitaka J. Application of Hybridization Chain Reaction/CRISPR-Cas12a for the Detection of SARS-CoV-2 Infection. Diagnostics (Basel) 2023; 13:diagnostics13091644. [PMID: 37175035 PMCID: PMC10178590 DOI: 10.3390/diagnostics13091644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 04/19/2023] [Accepted: 04/26/2023] [Indexed: 05/15/2023] Open
Abstract
Globally, the emergence of the coronavirus disease (COVID-19) has had a significant impact on life. The need for ongoing SARS-CoV-2 screening employing inexpensive and quick diagnostic approaches is undeniable, given the ongoing pandemic and variations in vaccine administration in resource-constrained regions. This study presents results as proof of concept to use hybridization chain reaction (HCR) and clustered regularly interspaced short palindromic repeats (CRISPR)/Cas12a complex for detecting SARS-CoV-2. HCR hairpin probes were designed using the NUPACK web-based program and further used to amplify the SARS-CoV-2 N gene in archived nasopharyngeal samples. The results were visualized using agarose gels and CRISPR Cas12a-based lateral flow strips. The assay was evaluated using the gold standard, real-time polymerase chain reaction (RT-PCR), as recommended by the World Health Organization (WHO). The results show the comparative efficiency of HCR to RT-PCR. This study shows that HCR and CRISPR are viable alternatives for diagnosing SARS-CoV-2 in samples.
Collapse
Affiliation(s)
- Kate Obaayaa Sagoe
- Department of Molecular Biology and Biotechnology, Pan African University Institute for Basic Sciences, Technology and Innovation (PAUSTI), Nairobi P.O. Box 62000-00200, Kenya
| | - Mutinda Cleophas Kyama
- Department of Medical Laboratory Science, College of Health Sciences, Jomo Kenyatta University of Agriculture & Technology, Nairobi P.O. Box 62000-00200, Kenya
| | - Naomi Maina
- Department of Biochemistry, College of Health Sciences, Jomo Kenyatta University of Agriculture & Technology, Nairobi P.O. Box 62000-00200, Kenya
| | - Moses Kamita
- Directorate of Research and Innovation, Mount Kenya University, Thika P.O. Box 342-01000, Kenya
| | - Muturi Njokah
- Department of Biochemistry, College of Health Sciences, Jomo Kenyatta University of Agriculture & Technology, Nairobi P.O. Box 62000-00200, Kenya
| | - Kelvin Thiong'o
- Center for Biotechnology Research and Development, Kenya Medical Research Institute, Nairobi P.O. Box 54840-00200, Kenya
| | - Bernard N Kanoi
- Directorate of Research and Innovation, Mount Kenya University, Thika P.O. Box 342-01000, Kenya
| | - Ernest Apondi Wandera
- Directorate of Research and Innovation, Mount Kenya University, Thika P.O. Box 342-01000, Kenya
- Center for Virus Research, Kenya Medical Research Institute, Nairobi P.O. Box 54840-00200, Kenya
| | - Davies Ndegwa
- Department of Medical Laboratory Sciences, Kenya Medical Training College, Nairobi P.O. Box 30195-00100, Kenya
| | - Dickson Mwenda Kinyua
- Department of Physical Sciences, Meru University of Science & Technology, Meru P.O. Box 972-60200, Kenya
- Department of Pure and Applied Sciences, Kirinyaga University, Kerugoya P.O. Box 143-10300, Kenya
| | - Jesse Gitaka
- Directorate of Research and Innovation, Mount Kenya University, Thika P.O. Box 342-01000, Kenya
| |
Collapse
|
58
|
de Olazarra AS, Wang SX. Advances in point-of-care genetic testing for personalized medicine applications. BIOMICROFLUIDICS 2023; 17:031501. [PMID: 37159750 PMCID: PMC10163839 DOI: 10.1063/5.0143311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Accepted: 04/12/2023] [Indexed: 05/11/2023]
Abstract
Breakthroughs within the fields of genomics and bioinformatics have enabled the identification of numerous genetic biomarkers that reflect an individual's disease susceptibility, disease progression, and therapy responsiveness. The personalized medicine paradigm capitalizes on these breakthroughs by utilizing an individual's genetic profile to guide treatment selection, dosing, and preventative care. However, integration of personalized medicine into routine clinical practice has been limited-in part-by a dearth of widely deployable, timely, and cost-effective genetic analysis tools. Fortunately, the last several decades have been characterized by tremendous progress with respect to the development of molecular point-of-care tests (POCTs). Advances in microfluidic technologies, accompanied by improvements and innovations in amplification methods, have opened new doors to health monitoring at the point-of-care. While many of these technologies were developed with rapid infectious disease diagnostics in mind, they are well-suited for deployment as genetic testing platforms for personalized medicine applications. In the coming years, we expect that these innovations in molecular POCT technology will play a critical role in enabling widespread adoption of personalized medicine methods. In this work, we review the current and emerging generations of point-of-care molecular testing platforms and assess their applicability toward accelerating the personalized medicine paradigm.
Collapse
Affiliation(s)
- A. S. de Olazarra
- Department of Electrical Engineering, Stanford University, Stanford, California 94305, USA
| | - S. X. Wang
- Author to whom correspondence should be addressed:
| |
Collapse
|
59
|
Trzaskowski M, Mazurkiewicz-Pisarek A, Trzciński JW, Drozd M, Podgórski R, Zabost A, Augustynowicz-Kopeć E. Portable Surface Plasmon Resonance Detector for COVID-19 Infection. SENSORS (BASEL, SWITZERLAND) 2023; 23:3946. [PMID: 37112287 PMCID: PMC10144119 DOI: 10.3390/s23083946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 04/05/2023] [Accepted: 04/11/2023] [Indexed: 06/19/2023]
Abstract
Methods based on nucleic acid detection are currently the most commonly used technique in COVID-19 diagnostics. Although generally considered adequate, these methods are characterised by quite a long time-to-result and the necessity to prepare the material taken from the examined person-RNA isolation. For this reason, new detection methods are being sought, especially those characterised by the high speed of the analysis process from the moment of sampling to the result. Currently, serological methods of detecting antibodies against the virus in the patient's blood plasma have attracted much attention. Although they are less precise in determining the current infection, such methods shorten the analysis time to several minutes, making it possible to consider them a promising method for screening tests in people with suspected infection. The described study investigated the feasibility of a surface plasmon resonance (SPR)-based detection system for on-site COVID-19 diagnostics. A simple-to-use portable device was proposed for the fast detection of anti-SARS-CoV-2 antibodies in human plasma. SARS-CoV-2-positive and -negative patient blood plasma samples were investigated and compared with the ELISA test. The receptor-binding domain (RBD) of spike protein from SARS-CoV-2 was selected as a binding molecule for the study. Then, the process of antibody detection using this peptide was examined under laboratory conditions on a commercially available SPR device. The portable device was prepared and tested on plasma samples from humans. The results were compared with those obtained in the same patients using the reference diagnostic method. The detection system is effective in the detection of anti-SARS-CoV-2 with the detection limit of 40 ng/mL. It was shown that it is a portable device that can correctly examine human plasma samples within a 10 min timeframe.
Collapse
Affiliation(s)
- Maciej Trzaskowski
- Centre for Advanced Materials and Technologies CEZAMAT, Warsaw University of Technology, Poleczki 19, 02-822 Warsaw, Poland
| | - Anna Mazurkiewicz-Pisarek
- Centre for Advanced Materials and Technologies CEZAMAT, Warsaw University of Technology, Poleczki 19, 02-822 Warsaw, Poland
| | - Jakub Waldemar Trzciński
- Centre for Advanced Materials and Technologies CEZAMAT, Warsaw University of Technology, Poleczki 19, 02-822 Warsaw, Poland
- Faculty of Chemical and Process Engineering, Warsaw University of Technology, Waryńskiego 1, 00-645 Warsaw, Poland
| | - Marcin Drozd
- Centre for Advanced Materials and Technologies CEZAMAT, Warsaw University of Technology, Poleczki 19, 02-822 Warsaw, Poland
| | - Rafał Podgórski
- Faculty of Chemical and Process Engineering, Warsaw University of Technology, Waryńskiego 1, 00-645 Warsaw, Poland
| | - Anna Zabost
- Department of Microbiology, Institute of Tuberculosis and Lung Diseases, Płocka 26, 01-138 Warsaw, Poland
| | - Ewa Augustynowicz-Kopeć
- Department of Microbiology, Institute of Tuberculosis and Lung Diseases, Płocka 26, 01-138 Warsaw, Poland
| |
Collapse
|
60
|
Kang BH, Jang KW, Yu ES, Na H, Lee YJ, Ko WY, Bae N, Rho D, Jeong KH. Ultrafast Plasmonic Nucleic Acid Amplification and Real-Time Quantification for Decentralized Molecular Diagnostics. ACS NANO 2023; 17:6507-6518. [PMID: 36971140 PMCID: PMC10081571 DOI: 10.1021/acsnano.2c11831] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/27/2022] [Accepted: 03/23/2023] [Indexed: 06/18/2023]
Abstract
Point-of-care real-time reverse-transcription polymerase chain reaction (RT-PCR) facilitates the widespread use of rapid, accurate, and cost-effective near-patient testing that is available to the public. Here, we report ultrafast plasmonic nucleic acid amplification and real-time quantification for decentralized molecular diagnostics. The plasmonic real-time RT-PCR system features an ultrafast plasmonic thermocycler (PTC), a disposable plastic-on-metal (PoM) cartridge, and an ultrathin microlens array fluorescence (MAF) microscope. The PTC provides ultrafast photothermal cycling under white-light-emitting diode illumination and precise temperature monitoring with an integrated resistance temperature detector. The PoM thin film cartridge allows rapid heat transfer as well as complete light blocking from the photothermal excitation source, resulting in real-time and highly efficient PCR quantification. Besides, the MAF microscope exhibits close-up and high-contrast fluorescence microscopic imaging. All of the systems were fully packaged in a palm size for point-of-care testing. The real-time RT-PCR system demonstrates the rapid diagnosis of coronavirus disease-19 RNA virus within 10 min and yields 95.6% of amplification efficiency, 96.6% of classification accuracy for preoperational test, and 91% of total percent agreement for clinical diagnostic test. The ultrafast and compact PCR system can decentralize point-of-care molecular diagnostic testing in primary care and developing countries.
Collapse
Affiliation(s)
- Byoung-Hoon Kang
- Department
of Bio and Brain Engineering, Korea Advanced
Institute of Science and Technology (KAIST), 291 Daehak-ro,
Yuseong-gu, Daejeon 34141, Republic of Korea
- KAIST
Institute for Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro,
Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Kyung-Won Jang
- Department
of Bio and Brain Engineering, Korea Advanced
Institute of Science and Technology (KAIST), 291 Daehak-ro,
Yuseong-gu, Daejeon 34141, Republic of Korea
- KAIST
Institute for Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro,
Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Eun-Sil Yu
- Department
of Bio and Brain Engineering, Korea Advanced
Institute of Science and Technology (KAIST), 291 Daehak-ro,
Yuseong-gu, Daejeon 34141, Republic of Korea
- KAIST
Institute for Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro,
Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Hamin Na
- Department
of Bio and Brain Engineering, Korea Advanced
Institute of Science and Technology (KAIST), 291 Daehak-ro,
Yuseong-gu, Daejeon 34141, Republic of Korea
- KAIST
Institute for Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro,
Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Yun-Jae Lee
- OSANG
Healthcare Co., Ltd., 132, Anyangcheondong-ro, Dongan-gu, Anyang-si, Gyeonggi-do 14040, Korea
| | - Woong-Yeol Ko
- OSANG
Healthcare Co., Ltd., 132, Anyangcheondong-ro, Dongan-gu, Anyang-si, Gyeonggi-do 14040, Korea
| | - NamHo Bae
- Center
for Nano Bio Development, National NanoFab
Center (NNFC), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Donggee Rho
- Center
for Nano Bio Development, National NanoFab
Center (NNFC), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Ki-Hun Jeong
- Department
of Bio and Brain Engineering, Korea Advanced
Institute of Science and Technology (KAIST), 291 Daehak-ro,
Yuseong-gu, Daejeon 34141, Republic of Korea
- KAIST
Institute for Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro,
Yuseong-gu, Daejeon 34141, Republic of Korea
| |
Collapse
|
61
|
Yang S, Xian Q, Liu Y, Zhang Z, Song Q, Gao Y, Wen W. A Silicon-Based PDMS-PEG Copolymer Microfluidic Chip for Real-Time Polymerase Chain Reaction Diagnosis. J Funct Biomater 2023; 14:jfb14040208. [PMID: 37103298 PMCID: PMC10143339 DOI: 10.3390/jfb14040208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 04/02/2023] [Accepted: 04/07/2023] [Indexed: 04/28/2023] Open
Abstract
Polydimethylsiloxane (PDMS) has been widely used to make lab-on-a-chip devices, such as reactors and sensors, for biological research. Real-time nucleic acid testing is one of the main applications of PDMS microfluidic chips due to their high biocompatibility and transparency. However, the inherent hydrophobicity and excessive gas permeability of PDMS hinder its applications in many fields. This study developed a silicon-based polydimethylsiloxane-polyethylene-glycol (PDMS-PEG) copolymer microfluidic chip, the PDMS-PEG copolymer silicon chip (PPc-Si chip), for biomolecular diagnosis. By adjusting the modifier formula for PDMS, the hydrophilic switch occurred within 15 s after contact with water, resulting in only a 0.8% reduction in transmittance after modification. In addition, we evaluated the transmittance at a wide range of wavelengths from 200 nm to 1000 nm to provide a reference for its optical property study and application in optical-related devices. The improved hydrophilicity was achieved by introducing a large number of hydroxyl groups, which also resulted in excellent bonding strength of PPc-Si chips. The bonding condition was easy to achieve and time-saving. Real-time PCR tests were successfully conducted with higher efficiency and lower non-specific absorption. This chip has a high potential for a wide range of applications in point-of-care tests (POCT) and rapid disease diagnosis.
Collapse
Affiliation(s)
- Siyu Yang
- Division of Emerging Interdisciplinary Areas, Interdisciplinary Program Office, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
- Thrust of Advanced Materials, The Hong Kong University of Science and Technology (Guangzhou), Nansha, Guangzhou 511400, China
- HKUST Shenzhen-Hong Kong Collaborative Innovation Research Institute, Futian, Shenzhen 518000, China
| | - Qingyue Xian
- Division of Emerging Interdisciplinary Areas, Interdisciplinary Program Office, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
- Thrust of Advanced Materials, The Hong Kong University of Science and Technology (Guangzhou), Nansha, Guangzhou 511400, China
| | - Yiteng Liu
- Division of Emerging Interdisciplinary Areas, Interdisciplinary Program Office, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
- Thrust of Advanced Materials, The Hong Kong University of Science and Technology (Guangzhou), Nansha, Guangzhou 511400, China
| | - Ziyi Zhang
- Division of Emerging Interdisciplinary Areas, Interdisciplinary Program Office, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
- Thrust of Advanced Materials, The Hong Kong University of Science and Technology (Guangzhou), Nansha, Guangzhou 511400, China
| | - Qi Song
- Department of Physics, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - Yibo Gao
- Department of Physics, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - Weijia Wen
- Thrust of Advanced Materials, The Hong Kong University of Science and Technology (Guangzhou), Nansha, Guangzhou 511400, China
- HKUST Shenzhen-Hong Kong Collaborative Innovation Research Institute, Futian, Shenzhen 518000, China
- Department of Physics, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| |
Collapse
|
62
|
Mei J, Wang D, Zhang Y, Wu D, Cui J, Gan M, Liu P. Portable Paper-Based Nucleic Acid Enrichment for Field Testing. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2205217. [PMID: 36797206 PMCID: PMC10104631 DOI: 10.1002/advs.202205217] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Revised: 01/15/2023] [Indexed: 05/22/2023]
Abstract
Point-of-care testing (POCT) can be the method of choice for detecting infectious pathogens; these pathogens are responsible for not only infectious diseases such as COVID-19, but also for certain types of cancers. For example, infections by human papillomavirus (HPV) or Helicobacter pylori (H. pylori) are the main cause of cervical and stomach cancers, respectively. COVID-19 and many cancers are treatable with early diagnoses using POCT. A variety of nucleic acid testing have been developed for use in resource-limited environments. However, questions like unintegrated nucleic acid extraction, open detection systems increase the risk of cross-contamination, and dependence on expensive equipment and alternating current (AC) power supply, significantly limit the application of POCT, especially for on-site testing. In this paper, a simple portable platform is reported capable of rapid sample-to-answer testing within 30 min based on recombinase polymerase amplification (RPA) at a lower temperature, to detect SARS-CoV-2 virus and H. pylori bacteria with a limit of detection as low as 4 × 102 copies mL-1 . The platform used a battery-powered portable reader for on-chip one-pot amplification and fluorescence detection, and can test for multiple (up to four) infectious pathogens simultaneously. This platform can provide an alternative method for fast and reliable on-site diagnostic testing.
Collapse
Affiliation(s)
- Junyang Mei
- State Key Laboratory of Oncogenes and Related GenesShanghai Cancer InstituteRenji HospitalSchool of MedicineShanghai Jiao Tong UniversityShanghai200032China
- Central LaboratoryRenji HospitalSchool of MedicineShanghai Jiao Tong UniversityShanghai200127China
| | - Dandan Wang
- CAS Key Laboratory of Nano‐Bio InterfaceSuzhou Institute of Nano‐Tech and Nano‐BionicsChinese Academy of SciencesSuzhou215123China
| | - Yiheng Zhang
- State Key Laboratory of Oncogenes and Related GenesShanghai Cancer InstituteRenji HospitalSchool of MedicineShanghai Jiao Tong UniversityShanghai200032China
- Central LaboratoryRenji HospitalSchool of MedicineShanghai Jiao Tong UniversityShanghai200127China
| | - Dan Wu
- CAS Key Laboratory of Nano‐Bio InterfaceSuzhou Institute of Nano‐Tech and Nano‐BionicsChinese Academy of SciencesSuzhou215123China
| | - Jinhui Cui
- CAS Key Laboratory of Nano‐Bio InterfaceSuzhou Institute of Nano‐Tech and Nano‐BionicsChinese Academy of SciencesSuzhou215123China
| | - Mingzhe Gan
- CAS Key Laboratory of Nano‐Bio InterfaceSuzhou Institute of Nano‐Tech and Nano‐BionicsChinese Academy of SciencesSuzhou215123China
| | - Peifeng Liu
- State Key Laboratory of Oncogenes and Related GenesShanghai Cancer InstituteRenji HospitalSchool of MedicineShanghai Jiao Tong UniversityShanghai200032China
- Central LaboratoryRenji HospitalSchool of MedicineShanghai Jiao Tong UniversityShanghai200127China
| |
Collapse
|
63
|
Lin B, Geng Z, Chen Y, Zeng W, Li B, Zhang Y, Liu P. A fully integrated nucleic acid analysis system for multiplex detection of genetic polymorphisms related to folic acid metabolism. LAB ON A CHIP 2023; 23:1794-1803. [PMID: 36806417 DOI: 10.1039/d2lc01169g] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
A sufficient intake of folic acid is essential during pregnancy, but several genetic polymorphisms reduce its absorption, threaten the lives of pregnant women and cause congenital disabilities in newborns. Traditional laboratory detection of genetic variants related to folic acid metabolism is time-consuming and labor-intensive. Microfluidics-based molecular diagnosis integrates sample pre-processing and nucleic acid amplification on-chip to achieve rapid, sensitive, high-throughput, and automated detection. Here, we developed a fully integrated microfluidic system for the detection of genetic polymorphisms related to folic acid metabolism in a "sample in-answer out" style. The system consists of nucleic acid extraction and amplification modules. During nucleic acid extraction, blood cells are lysed, and DNA is captured and eluted through a silica-gel membrane. After that, multiple gene loci are detected using loop-mediated isothermal amplification (LAMP) and the color of the reaction chamber indicates whether genetic mutations are present. The experimental results demonstrate that the system can accurately detect gene polymorphisms associated with folic acid metabolism in blood samples with high sensitivity and no cross-contamination between chambers. The blood samples of five patients were tested for mutant alleles on this system, and the test results were consistent with qPCR and DNA sequencing observations. The operation is fully automated, and the detection is completed in approximately 70 minutes. The proposed system has great potential in prenatal diagnosis and other types of nucleic acid detection.
Collapse
Affiliation(s)
- Baobao Lin
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Haidian District, Beijing, 100084, China.
| | - Zhi Geng
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Haidian District, Beijing, 100084, China.
| | - Yanjing Chen
- Sports & Medicine Integration Research Center (SMIRC), Capital University of Physical Education and Sports, Haidian District, Beijing, 100191, China.
| | - Wu Zeng
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Haidian District, Beijing, 100084, China.
| | - Bao Li
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Haidian District, Beijing, 100084, China.
| | - Yan Zhang
- Sports & Medicine Integration Research Center (SMIRC), Capital University of Physical Education and Sports, Haidian District, Beijing, 100191, China.
| | - Peng Liu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Haidian District, Beijing, 100084, China.
| |
Collapse
|
64
|
Sivakumar R, Park SY, Lee NY. Quercetin-Mediated Silver Nanoparticle Formation for the Colorimetric Detection of Infectious Pathogens Coupled with Loop-Mediated Isothermal Amplification. ACS Sens 2023; 8:1422-1430. [PMID: 36952605 DOI: 10.1021/acssensors.2c02054] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/25/2023]
Abstract
Here, quercetin-mediated silver nanoparticle (AgNP) formation combined with loop-mediated isothermal amplification (LAMP) was introduced to colorimetrically detect two major infectious pathogens, SARS-CoV-2 and Enterococcus faecium, using a foldable PMMA microdevice. The nitrogenous bases of LAMP amplicons can readily form a complex with Ag+ ions, and the catechol moiety in quercetin, which acted as a reducing agent, could be chelated with Ag+ ions, resulting in the easy electron transfer from the oxidant to the reductant and producing brown-colored AgNPs within 5 min. The introduced method exhibited higher sensitivity than agarose gel electrophoresis due to more active redox centers in quercetin. The detection limit was attained at 101 copies μL-1 and 101 CFU mL-1 for SARS-CoV-2 RNA and E. faecium, respectively. A foldable microdevice made of two pieces of PMMA that fully integrates DNA extraction, amplification, and detection processes was fabricated to establish practical applicability. On one PMMA, DNA extraction was performed in a reaction chamber inserted with an FTA card, and then LAMP reagents were added for amplification. Silver nitrate was added to the reaction chamber after LAMP. On the other PMMA, quercetin-soaked paper discs loaded in the detection chamber were folded toward the reaction chamber for colorimetric detection. An intense brown color was produced within 5 min when heated at 65 °C. The introduced colorimetric assay, which is highly favorable for laboratory and on-site applications, could be a valuable alternative to conventional methods for detecting infectious diseases, given its unique principle, simplicity, and naked-eye detection.
Collapse
Affiliation(s)
- Rajamanickam Sivakumar
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, South Korea
| | - So Yeon Park
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, South Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, South Korea
| |
Collapse
|
65
|
Liu S, Xie T, Pei X, Li S, He Y, Tong Y, Liu G. CRISPR-Cas12a coupled with universal gold nanoparticle strand-displacement probe for rapid and sensitive visual SARS-CoV-2 detection. SENSORS AND ACTUATORS. B, CHEMICAL 2023; 377:133009. [PMID: 36439054 PMCID: PMC9678389 DOI: 10.1016/j.snb.2022.133009] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 11/04/2022] [Accepted: 11/16/2022] [Indexed: 05/27/2023]
Abstract
Point of care (POC) diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are particularly significant for preventing transmission of coronavirus disease 2019 (COVID-19) by any user at any given time and place. CRISPR/Cas-assisted SARS-CoV-2 assays are viewed as supplemental to RT-PCR due to simple operation, convenient use and low cost. However, most current CRISPR molecular diagnostics based on fluorescence measurement increased the difficulty of POC test with need of the additional light sources. Some instrument-free visual detection with the naked eye has limitations in probe universality. Herein, we developed a universal, rapid, sensitive and specific SARS-CoV-2 POC test that combines the outstanding DNase activity of Cas12a with universal AuNPs strand-displacement probe. The oligo trigger, which is the switch the AuNPs of the strand-displacement probe, is declined as a result of Cas12a recognition and digestion. The amount of released AuNPs produced color change which can be visual with the naked eye and assessed by UV-Vis spectrometer for quantitative detection. Furthermore, a low-cost hand warmer is used as an incubator for the visual assay, enabling an instrument-free, visual SARS-CoV-2 detection within 20 min. A real coronavirus GX/P2V instead of SARS-CoV-2 were chosen for practical application validation. After rapid virus RNA extraction and RT-PCR amplification, a minimum of 2.7 × 102 copies/mL was obtained successfully. The modular design can be applied to many nucleic acid detection applications, such as viruses, bacteria, species, etc., by simply modifying the crRNA, showing great potential in POC diagnosis.
Collapse
Affiliation(s)
- Sitong Liu
- College of Chemistry and Materials Engineering and Institute of Cosmetic Regulatory Science, Beijing Technology and Business University, Beijing 100048, PR China
| | - Tie Xie
- College of Chemistry and Materials Engineering, Beijing Technology and Business University, Beijing 100048, PR China
| | - Xiaojing Pei
- College of Chemistry and Materials Engineering and Institute of Cosmetic Regulatory Science, Beijing Technology and Business University, Beijing 100048, PR China
| | - Shujing Li
- College of Chemistry and Materials Engineering and Institute of Cosmetic Regulatory Science, Beijing Technology and Business University, Beijing 100048, PR China
| | - Yifan He
- College of Chemistry and Materials Engineering and Institute of Cosmetic Regulatory Science, Beijing Technology and Business University, Beijing 100048, PR China
| | - Yigang Tong
- College of Chemistry and Materials Engineering, Beijing Technology and Business University, Beijing 100048, PR China
| | - Guoqi Liu
- Biotecnovo (Beijing) Co.,LTD, Beijing Economic and Technological Development Zone, Beijing, PR China
| |
Collapse
|
66
|
Zhang L, Wang X, Liu D, Wu Y, Feng L, Han C, Liu J, Lu Y, Sotnikov DV, Xu Y, Cheng J. SMART: A Swing-Assisted Multiplexed Analyzer for Point-of-Care Respiratory Tract Infection Testing. BIOSENSORS 2023; 13:228. [PMID: 36831994 PMCID: PMC9954503 DOI: 10.3390/bios13020228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Revised: 01/26/2023] [Accepted: 02/02/2023] [Indexed: 06/18/2023]
Abstract
Respiratory tract infections such as the ongoing coronavirus disease 2019 (COVID-19) has seriously threatened public health in the last decades. The experience of fighting against the epidemic highlights the importance of user-friendly and accessible point-of-care systems for nucleic acid (NA) detection. To realize low-cost and multiplexed point-of-care NA detection, a swing-assisted multiplexed analyzer for point-of-care respiratory tract infection testing (SMART) was proposed to detect multiple respiratory tract pathogens using visible loop-mediated isothermal amplification. By performing hand-swing movements to generate acceleration force to distribute samples into reaction chambers, the design of the SMART system was greatly simplified. By using different format of chips and integrating into a suitcase, this system can be applied to on-site multitarget and multi-sample testing. Three targets including the N and Orf genes of SARS-CoV-2 and the internal control were simultaneously analyzed (limit of detection: 2000 copies/mL for raw sample; 200 copies/mL for extracted sample). Twenty-three clinical samples with eight types of respiratory bacteria and twelve COVID-19 clinical samples were successfully detected. These results indicate that the SMART system has the potential to be further developed as a versatile tool in the diagnosis of respiratory tract infection.
Collapse
Affiliation(s)
- Li Zhang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Xu Wang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Dongchen Liu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Yu Wu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Li Feng
- CapitalBiotech Technology, Beijing 101111, China
| | - Chunyan Han
- CapitalBiotech Technology, Beijing 101111, China
| | - Jiajia Liu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Ying Lu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
- National Engineering Research Center for Beijing Biochip Technology, Beijing 102200, China
| | - Dmitriy V. Sotnikov
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia
| | - Youchun Xu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
- National Engineering Research Center for Beijing Biochip Technology, Beijing 102200, China
| | - Jing Cheng
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
- National Engineering Research Center for Beijing Biochip Technology, Beijing 102200, China
| |
Collapse
|
67
|
Tavakoli-Koopaei R, Javadi-Zarnaghi F, Aboutalebian S, Mirhendi H. Malachite Green-Based Detection of SARS-CoV-2 by One-Step Reverse Transcription Loop-Mediated Isothermal Amplification. IRANIAN JOURNAL OF SCIENCE 2023. [PMCID: PMC9898859 DOI: 10.1007/s40995-022-01392-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
The pandemic of severe acute respiratory syndrome 2 (SARS-CoV-2) revealed the necessity of diagnosis of the infected people to prevent the prevalence infection cycle. Many commercial pathogen diagnosis methods are based on the detection of genomic materials. Isothermal amplification methods such as loop-mediated-isothermal amplification (LAMP) are the method of choice in these cases. Reverse transcription steps are efficiently coupled to LAMP for the detection of pathogens with genomic RNAs such as SARS-CoV-2. Many detection systems for LAMP include fluorescent readout systems. Although such systems result in desirable limits of detection, the need for special instrumentation is the main dispute of such systems to become real point of care assays. In contrast, colorimetric detection methods would reduce costs and improve the applicability of the system. In this study one-step reverse transcription-LAMP reaction was established that enables visual detection of the SARS-CoV-2 genome. Nasopharyngeal RNA samples were first validated by reverse transcription quantitative polymerase chain reaction and then subjected to RT-LAMP. To lower the cost associated with the readout system equipment, malachite green (MG) was used. The color change of MG to blue allowed visual detection of the virus. Firstly, experiments were set up as two-step RT-LAMP reaction to identify the best primer sets. In addition, MG concentration was optimized with the significant colorimetric signal for the positive samples. Next, a one-step colorimetric method was developed for the detection of SARS-CoV-2 based on MG color shift in 2 h.
Collapse
Affiliation(s)
- Reyhaneh Tavakoli-Koopaei
- grid.411750.60000 0001 0454 365XDepartment of Cell and Molecular Biology & Microbiology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, Iran
| | - Fatemeh Javadi-Zarnaghi
- grid.411750.60000 0001 0454 365XDepartment of Cell and Molecular Biology & Microbiology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, Iran
| | - Shima Aboutalebian
- grid.411036.10000 0001 1498 685XDepartment of Medical Parasitology and Mycology, School of Medicine, Research Core Facilities Laboratory, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Hossein Mirhendi
- grid.411036.10000 0001 1498 685XDepartment of Medical Parasitology and Mycology, School of Medicine, Research Core Facilities Laboratory, Isfahan University of Medical Sciences, Isfahan, Iran
| |
Collapse
|
68
|
Yang S, Zhang Z, Xian Q, Song Q, Liu Y, Gao Y, Wen W. An Aluminum-Based Microfluidic Chip for Polymerase Chain Reaction Diagnosis. Molecules 2023; 28:molecules28031085. [PMID: 36770751 PMCID: PMC9921548 DOI: 10.3390/molecules28031085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 01/13/2023] [Accepted: 01/18/2023] [Indexed: 01/24/2023] Open
Abstract
Real-time polymerase chain reaction (real-time PCR) tests were successfully conducted in an aluminum-based microfluidic chip developed in this work. The reaction chamber was coated with silicone-modified epoxy resin to isolate the reaction system from metal surfaces, preventing the metal ions from interfering with the reaction process. The patterned aluminum substrate was bonded with a hydroxylated glass mask using silicone sealant at room temperature. The effect of thermal expansion was counteracted by the elasticity of cured silicone. With the heating process closely monitored, real-time PCR testing in reaction chambers proceeded smoothly, and the results show similar quantification cycle values to those of traditional test sets. Scanning electron microscope (SEM) and atomic force microscopy (AFM) images showed that the surface of the reaction chamber was smoothly coated, illustrating the promising coating and isolating properties. Energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and inductively coupled plasma-optical emission spectrometer (ICP-OES) showed that no metal ions escaped from the metal to the chip surface. Fourier-transform infrared spectroscopy (FTIR) was used to check the surface chemical state before and after tests, and the unchanged infrared absorption peaks indicated the unreacted, antifouling surface. The limit of detection (LOD) of at least two copies can be obtained in this chip.
Collapse
Affiliation(s)
- Siyu Yang
- Division of Emerging Interdisciplinary Areas, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR 999077, China
| | - Ziyi Zhang
- Division of Emerging Interdisciplinary Areas, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR 999077, China
| | - Qingyue Xian
- Division of Emerging Interdisciplinary Areas, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR 999077, China
| | - Qi Song
- Department of Physics, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR 999077, China
| | - Yiteng Liu
- Division of Emerging Interdisciplinary Areas, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR 999077, China
| | - Yibo Gao
- Department of Physics, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR 999077, China
| | - Weijia Wen
- Department of Physics, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR 999077, China
- Thrust of Advanced Materials, The Hong Kong University of Science and Technology (Guangzhou), Nansha, Guangzhou 511400, China
- HKUST Shenzhen-Hong Kong Collaborative Innovation Research Institute, Futian, Shenzhen 518000, China
- Correspondence: ; Tel.: +852-2358-5781
| |
Collapse
|
69
|
Ning B, Chandra S, Rosen J, Multala E, Argrave M, Pierson L, Trinh I, Simone B, Escarra MD, Drury S, Zwezdaryk KJ, Norton E, Lyon CJ, Hu T. Evaluation of SARS-CoV-2-Specific T-Cell Activation with a Rapid On-Chip IGRA. ACS NANO 2023; 17:1206-1216. [PMID: 36595218 PMCID: PMC9878992 DOI: 10.1021/acsnano.2c09018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Accepted: 12/29/2022] [Indexed: 06/17/2023]
Abstract
Interferon-gamma release assays (IGRAs) that measure pathogen-specific T-cell response rates can provide a more reliable estimate of protection than specific antibody levels but have limited potential for widespread use due to their workflow, personnel, and instrumentation demands. The major vaccines for SARS-CoV-2 have demonstrated substantial efficacy against all of its current variants, but approaches are needed to determine how these vaccines will perform against future variants, as they arise, to inform vaccine and public health policies. Here we describe a rapid, sensitive, nanolayer polylysine-integrated microfluidic chip IGRA read by a fluorescent microscope that has a 5 h sample-to-answer time and uses ∼25 μL of a fingerstick whole blood sample. Results from this assay correlated with those of a comparable clinical IGRA when used to evaluate the T-cell response to SARS-CoV-2 peptides in a population of vaccinated and/or infected individuals. Notably, this streamlined and inexpensive assay is suitable for high-throughput analyses in resource-limited settings for other infectious diseases.
Collapse
Affiliation(s)
- Bo Ning
- Center
for Cellular and Molecular Diagnostics, Tulane University School of Medicine, New Orleans, Louisiana 70112, United States
- Department
of Biochemistry and Molecular Biology, Tulane
University School of Medicine, New Orleans, Louisiana 70112, United States
| | - Sutapa Chandra
- Center
for Cellular and Molecular Diagnostics, Tulane University School of Medicine, New Orleans, Louisiana 70112, United States
- Department
of Biochemistry and Molecular Biology, Tulane
University School of Medicine, New Orleans, Louisiana 70112, United States
| | - Juniper Rosen
- Center
for Cellular and Molecular Diagnostics, Tulane University School of Medicine, New Orleans, Louisiana 70112, United States
- Department
of Biochemistry and Molecular Biology, Tulane
University School of Medicine, New Orleans, Louisiana 70112, United States
| | - Evan Multala
- Center
for Cellular and Molecular Diagnostics, Tulane University School of Medicine, New Orleans, Louisiana 70112, United States
- Department
of Biochemistry and Molecular Biology, Tulane
University School of Medicine, New Orleans, Louisiana 70112, United States
| | - Melvin Argrave
- Center
for Cellular and Molecular Diagnostics, Tulane University School of Medicine, New Orleans, Louisiana 70112, United States
- Department
of Biochemistry and Molecular Biology, Tulane
University School of Medicine, New Orleans, Louisiana 70112, United States
| | - Lane Pierson
- Center
for Cellular and Molecular Diagnostics, Tulane University School of Medicine, New Orleans, Louisiana 70112, United States
- Department
of Biochemistry and Molecular Biology, Tulane
University School of Medicine, New Orleans, Louisiana 70112, United States
| | - Ivy Trinh
- Department
of Microbiology & Immunology, Tulane
University School of Medicine, New Orleans, Louisiana 70112, United States
| | - Brittany Simone
- Department
of Physics and Engineering Physics, Tulane
University, New Orleans, Louisiana 70118, United States
| | - Matthew David Escarra
- Department
of Physics and Engineering Physics, Tulane
University, New Orleans, Louisiana 70118, United States
| | - Stacy Drury
- Department
of Psychiatry, Tulane University, New Orleans, Louisiana 70112, United States
- Tulane
Brain
Institute, Tulane University, New Orleans, Louisiana 70112, United States
| | - Kevin J. Zwezdaryk
- Department
of Microbiology & Immunology, Tulane
University School of Medicine, New Orleans, Louisiana 70112, United States
| | - Elizabeth Norton
- Department
of Microbiology & Immunology, Tulane
University School of Medicine, New Orleans, Louisiana 70112, United States
| | - Christopher J. Lyon
- Center
for Cellular and Molecular Diagnostics, Tulane University School of Medicine, New Orleans, Louisiana 70112, United States
- Department
of Biochemistry and Molecular Biology, Tulane
University School of Medicine, New Orleans, Louisiana 70112, United States
| | - Tony Hu
- Center
for Cellular and Molecular Diagnostics, Tulane University School of Medicine, New Orleans, Louisiana 70112, United States
- Department
of Biochemistry and Molecular Biology, Tulane
University School of Medicine, New Orleans, Louisiana 70112, United States
| |
Collapse
|
70
|
Foster T, Khaiboullina S. Editorial: Community series - innovative approaches in diagnosis of emerging/re-emerging infectious diseases, volume II. Front Microbiol 2023; 14:1193841. [PMID: 37213514 PMCID: PMC10193036 DOI: 10.3389/fmicb.2023.1193841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2023] [Accepted: 04/10/2023] [Indexed: 05/23/2023] Open
Affiliation(s)
- Toshana Foster
- Faculty of Medicine and Health Sciences, School of Veterinary Medicine and Science, Wolfson Centre for Global Virus Research, The University of Nottingham, Loughborough, United Kingdom
| | - Svetlana Khaiboullina
- Department of Microbiology, University of Nevada, Reno, Reno, NV, United States
- *Correspondence: Svetlana Khaiboullina
| |
Collapse
|
71
|
Li D, Sun C, Mei X, Yang L. Achieving broad availability of SARS-CoV-2 detections via smartphone-based analysis. Trends Analyt Chem 2023; 158:116878. [PMID: 36506266 PMCID: PMC9728015 DOI: 10.1016/j.trac.2022.116878] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 12/01/2022] [Accepted: 12/06/2022] [Indexed: 12/13/2022]
Abstract
With the development of COVID-19, widely available tests are in great demand. Naked-eye SARS-CoV-2 test kits have recently been developed as home tests, but their sensitivity and accuracy are sometimes limited. Smartphones can convert various signals into digital information, potentially improving the sensitivity and accuracy of these home tests. Herein, we summarize smartphone-based detections for SARS-CoV-2. Optical detections of non-nucleic acids using various sensors and portable imaging systems, as well as nucleic acid analyses based on LAMP, CRISP, CATCH, and biosensors are discussed. Furthermore, different electrochemical detections were compared. We show results obtained using relatively complex equipment, complicated programming procedures, or custom smartphone apps, and describe methods for obtaining information with only simple setups and free software on smartphones. Then, the combined costs of typical smartphone-based detections are evaluated. Finally, the prospect of improving smartphone-based strategies to achieve broad availability of SARS-CoV-2 detection is proposed.
Collapse
Affiliation(s)
- Dan Li
- Jinzhou Medical University, Jinzhou, China
| | - Cai Sun
- AECC Shenyang Liming Aero-Engine Co, Ltd., Shenyang, China
| | - Xifan Mei
- Jinzhou Medical University, Jinzhou, China,Corresponding author
| | - Liqun Yang
- NHC Key Laboratory of Reproductive Health and Medical Genetics (China Medical University), Liaoning Research Institute of Family Planning (The Affiliated Reproductive Hospital of China Medical University), Shenyang, China,Corresponding author
| |
Collapse
|
72
|
Trinh KTL. Microfluidic Biosensors for Point-of-Care Nucleic Acid Amplification Tests. BIOSENSORS 2022; 13:5. [PMID: 36671840 PMCID: PMC9855661 DOI: 10.3390/bios13010005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 12/18/2022] [Indexed: 06/17/2023]
Abstract
This Special Issue of Biosensors, "Microfluidic Biosensors for Point-of-Care Nucleic Acid Amplification Tests" aims to gather original research papers and comprehensive reviews detailing novel research, fabrication methods, and applications, as well as the challenges and prospects of developing microfluidics for improved biosensing and diagnostics [...].
Collapse
Affiliation(s)
- Kieu The Loan Trinh
- Department of Industrial Environmental Engineering, Gachon University, Seongnam-si 13120, Republic of Korea
| |
Collapse
|
73
|
Clark K, Schenkel MS, Pittman TW, Samper IC, Anderson LBR, Khamcharoen W, Elmegerhi S, Perera R, Siangproh W, Kennan AJ, Geiss BJ, Dandy DS, Henry CS. Electrochemical Capillary Driven Immunoassay for Detection of SARS-CoV-2. ACS MEASUREMENT SCIENCE AU 2022; 2:584-594. [PMID: 36570470 PMCID: PMC9469961 DOI: 10.1021/acsmeasuresciau.2c00037] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 08/09/2022] [Accepted: 08/16/2022] [Indexed: 05/28/2023]
Abstract
The COVID-19 pandemic focused attention on a pressing need for fast, accurate, and low-cost diagnostic tests. This work presents an electrochemical capillary driven immunoassay (eCaDI) developed to detect SARS-CoV-2 nucleocapsid (N) protein. The low-cost flow device is made of polyethylene terephthalate (PET) and adhesive films. Upon addition of a sample, reagents and washes are sequentially delivered to an integrated screen-printed carbon electrode for detection, thus automating a full sandwich immunoassay with a single end-user step. The modified electrodes are sensitive and selective for SARS-CoV-2 N protein and stable for over 7 weeks. The eCaDI was tested with influenza A and Sindbis virus and proved to be selective. The eCaDI was also successfully applied to detect nine different SARS-CoV-2 variants, including Omicron.
Collapse
Affiliation(s)
- Kaylee
M. Clark
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Melissa S. Schenkel
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Trey W. Pittman
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Isabelle C. Samper
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Department
of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Loran B. R. Anderson
- Department
of Microbiology, Immunology, and Pathology, Colorado State University, Fort
Collins, Colorado 80523, United States
| | - Wisarut Khamcharoen
- Department
of Chemistry, Faculty of Science, Srinakharinwirot
University, Bangkok 10110, Thailand
| | - Suad Elmegerhi
- Department
of Microbiology, Immunology, and Pathology, Colorado State University, Fort
Collins, Colorado 80523, United States
| | - Rushika Perera
- Department
of Microbiology, Immunology, and Pathology, Colorado State University, Fort
Collins, Colorado 80523, United States
| | - Weena Siangproh
- Department
of Chemistry, Faculty of Science, Srinakharinwirot
University, Bangkok 10110, Thailand
| | - Alan J. Kennan
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Brian J. Geiss
- Department
of Microbiology, Immunology, and Pathology, Colorado State University, Fort
Collins, Colorado 80523, United States
- School
of Biomedical Engineering, Colorado State
University, Fort Collins, Colorado 80523, United States
| | - David S. Dandy
- Department
of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
- School
of Biomedical Engineering, Colorado State
University, Fort Collins, Colorado 80523, United States
| | - Charles S. Henry
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Department
of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
- School
of Biomedical Engineering, Colorado State
University, Fort Collins, Colorado 80523, United States
| |
Collapse
|
74
|
Bereda G. Confirmed COVID-19 in a Patient with Pre-Existing Pulmonary Tuberculosis: A Case Report.. [DOI: 10.21203/rs.3.rs-2373067/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Abstract
Co-infection with COVID-19 and TB frequently results in fever, coughing, hypotension, a changed blood cell count, raised liver enzymes, and decreased hemoglobin. On May 19, 2022, a retired black African woman in her 59s arrived at the emergency room with a tuberculosis diagnosis. She had no recent travel history and was COVID-19-infected. Five days prior to her admission, her sons, who worked in the medical field, were found to be infected with the COVID-19 infection. The patient arrived at the emergency room with weak muscles, a fever, a productive cough, a sore throat, a lack of appetite, a headache, night sweats, and shortness of breath that had lasted for a day. On chest auscultation, there were reduced breath sounds in the right middle and upper lungs. A Mycobacterium tuberculosis infection without rifampicin resistance was detected in a sputum sample using the GeneXpert Mycobacterium tuberculosis and rifampicin tests. After 36 hours, a throat swab polymerase chain reaction test produced positive findings, confirming the presence of the COVID-19 infection. The patient required continuous oxygen at a rate of four liters per minute via a nasal cannula for the first five days while in the hospital, and she is still taking her anti-tubercular medications. In order to combat hospital-acquired infections, she was given therapy with broad-spectrum antibiotics consisting of 500 mg of azithromycin given once a day for five days and 1 g of intravenous ceftriaxone administered daily for five days.
Collapse
|
75
|
Chen W, Chen H, Liu Y, Wei H, Wang Y, Rong Z, Liu X. An integrated fluorescent lateral flow assay for multiplex point-of-care detection of four respiratory viruses. Anal Biochem 2022; 659:114948. [PMID: 36216143 DOI: 10.1016/j.ab.2022.114948] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 09/24/2022] [Accepted: 10/03/2022] [Indexed: 12/14/2022]
Abstract
This work established a highly sensitive and specific quantum dot nanobeads-based lateral flow assay for multiplex detection of four respiratory virus markers at point of care. The respiratory virus antigens were detected by fluorescent lateral flow strips within 20 min. The limits of detection for SARS-CoV-2 antigen, IAV antigen, IBV antigen, and ADV antigen were 0.01 ng/mL, 0.05 ng/mL, 0.31 ng/mL, and 0.40 ng/mL, respectively, which were superior to that of conventional AuNPs-based colorimetric lateral flow assay. The coefficients of variation of the test strip were 6.09%, 2.24%, 7.92%, and 12.43% for these four antigens, which indicated that the proposed method had good repeatability. The specificity of the detection system was verified by different combinations of these four respiratory viruses and several other respiratory pathogens. These results indicated that this method could simultaneously detect SARS-CoV-2, IAV, IBV and ADV in a short assay time, showing the remarkable potential for the rapid and multiplex detection of respiratory viruses in resource-limited settings.
Collapse
Affiliation(s)
- Wenji Chen
- The First Affiliated Hospital of Jinzhou Medical University, Jinzhou, 121012, PR China; Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Hong Chen
- Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Ye Liu
- Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Hongjuan Wei
- Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Yunxiang Wang
- Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Zhen Rong
- Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China.
| | - Xin Liu
- The First Affiliated Hospital of Jinzhou Medical University, Jinzhou, 121012, PR China; Jinzhou Medical University Huludao Central Hospital Teaching Base, Huludao, 125001, PR China.
| |
Collapse
|
76
|
Štukovnik Z, Bren U. Recent Developments in Electrochemical-Impedimetric Biosensors for Virus Detection. Int J Mol Sci 2022; 23:ijms232415922. [PMID: 36555560 PMCID: PMC9788240 DOI: 10.3390/ijms232415922] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 12/07/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022] Open
Abstract
Viruses, including influenza viruses, MERS-CoV (Middle East respiratory syndrome coronavirus), SARS-CoV (severe acute respiratory syndrome coronavirus), HAV (Hepatitis A virus), HBV (Hepatitis B virus), HCV (Hepatitis C virus), HIV (human immunodeficiency virus), EBOV (Ebola virus), ZIKV (Zika virus), and most recently SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2), are responsible for many diseases that result in hundreds of thousands of deaths yearly. The ongoing outbreak of the COVID-19 disease has raised a global concern and intensified research on the detection of viruses and virus-related diseases. Novel methods for the sensitive, rapid, and on-site detection of pathogens, such as the recent SARS-CoV-2, are critical for diagnosing and treating infectious diseases before they spread and affect human health worldwide. In this sense, electrochemical impedimetric biosensors could be applied for virus detection on a large scale. This review focuses on the recent developments in electrochemical-impedimetric biosensors for the detection of viruses.
Collapse
Affiliation(s)
- Zala Štukovnik
- Faculty of Chemistry and Chemical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia
| | - Urban Bren
- Faculty of Chemistry and Chemical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia
- Faculty of Mathematics, Natural Sciences and Information Technologies, University of Primorska, Glagoljaška ulica 8, 6000 Koper, Slovenia
- Institute for Environmental Protection and Sensors, Beloruska ulica 7, 2000 Maribor, Slovenia
| |
Collapse
|
77
|
Chiu WH, Kong WY, Chueh YH, Wen JW, Tsai CM, Hong C, Chen PY, Ko CH. Using an ultra-compact optical system to improve lateral flow immunoassay results quantitatively. Heliyon 2022; 8:e12116. [PMID: 36544820 PMCID: PMC9761723 DOI: 10.1016/j.heliyon.2022.e12116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 10/02/2022] [Accepted: 11/28/2022] [Indexed: 12/12/2022] Open
Abstract
The lateral flow immunoassay (LFIA) is a paper-based platform with extensive application in point-of-care (POC) testing and many fields. However, its clinical application is severely limited due to the lack of quantitative ability of standard LFIA tests; this augmentation provides the system with quantifying the signal from magenta-colored AuNPs. To address this issue, we proposed an ultra-compact optical system that allowed LFIAs to be performed more accurately and objectively. The experimental setup consisted of multiple optical accessories manufactured by 3D printing (STEP files were included). A high-resolution printer was used to print out a magenta card model for the LFIA, whose color code, ranging from 255, 255, 255 to 255, 0, 255 in the RGB (red, green, blue) format, represents different levels of magenta color intensity (from 0% to 100%) and thus the results of LFIA test strips. A mathematical model was built using a calibration curve to describe the relationship between magenta color value and reflectance spectrum. In addition, a spectrum module was integrated into the proposed system to identify and quantify LFIA results. This integration represents a pioneering step in developing portable detection techniques that facilitate quantifying LFIA results. Finally, we expect this ultra-compact optical spectroscopy system to have great potential for novel clinical applications.
Collapse
Affiliation(s)
- Wei-Huai Chiu
- Graduate Institute of Automation and Control, National Taiwan University of Science and Technology, Taipei, Taiwan
| | - Wei-Yi Kong
- Graduate Institute of Automation and Control, National Taiwan University of Science and Technology, Taipei, Taiwan
| | - Yuan-Hui Chueh
- Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan
| | | | - Ciao-Ming Tsai
- Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan
| | | | - Pang-Yen Chen
- Department of Emergency Medicine, Mackay Memorial Hospital, Taipei, Taiwan
- Institute of Public Health, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Department of Nursing, Yuanpei University of Medical Technology, Hsinchu, Taiwan
| | - Cheng-Hao Ko
- Graduate Institute of Automation and Control, National Taiwan University of Science and Technology, Taipei, Taiwan
- Corresponding author.
| |
Collapse
|
78
|
Lian C, Young D, Randall RE, Samuel IDW. Organic Light-Emitting Diode Based Fluorescence-Linked Immunosorbent Assay for SARS-CoV-2 Antibody Detection. BIOSENSORS 2022; 12:1125. [PMID: 36551092 PMCID: PMC9775261 DOI: 10.3390/bios12121125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 11/22/2022] [Accepted: 11/24/2022] [Indexed: 06/17/2023]
Abstract
Immunodiagnostics have been widely used in the detection of disease biomarkers. The conventional immunological tests in central laboratories require expensive equipment and, for non-specialists, the tests are technically demanding and time-consuming, which has prevented their use by the public. Thus, point-of-care tests (POCT), such as lateral flow immunoassays, are being, or have been, developed as more convenient and low-cost methods for immunodiagnostics. However, the sensitivity of such tests is often a concern. Here, a fluorescence-linked immunosorbent assay (FLISA) using organic light-emitting diodes (OLEDs) as excitation light sources was investigated as a way forward for the development of compact and sensitive POCTs. Phycoerythrin (PE) was selected as the fluorescent dye, and OLEDs were designed with different emission spectra. The leakage light of different OLEDs for exciting PE was then investigated to reduce the background noise and improve the sensitivity of the system. Finally, as proof-of-principle that OLED-based technology can be successfully further developed for POCT, antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in human serum was detected by OLED-FLISA.
Collapse
Affiliation(s)
- Cheng Lian
- Organic Semiconductor Centre, SUPA, School of Physics and Astronomy, University of St Andrews, St Andrews KY16 9SS, UK
| | - Dan Young
- Centre for Biomolecular Sciences, School of Biology, University of St Andrews, St Andrews KY16 9ST, UK
| | - Richard E. Randall
- Centre for Biomolecular Sciences, School of Biology, University of St Andrews, St Andrews KY16 9ST, UK
| | - Ifor D. W. Samuel
- Organic Semiconductor Centre, SUPA, School of Physics and Astronomy, University of St Andrews, St Andrews KY16 9SS, UK
| |
Collapse
|
79
|
Perera GS, Rahman MA, Blazevski A, Wood A, Walia S, Bhaskaran M, Sriram S. Rapid Conductometric Detection of SARS-CoV-2 Proteins and Its Variants Using Molecularly Imprinted Polymer Nanoparticles. ADVANCED MATERIALS TECHNOLOGIES 2022; 8:2200965. [PMID: 36718387 PMCID: PMC9877662 DOI: 10.1002/admt.202200965] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 08/20/2022] [Indexed: 06/18/2023]
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) biosensors have captured more attention than the conventional methodologies for SARS-CoV-2 detection due to having cost-effective platforms and fast detection. However, these reported SARS-CoV-2 biosensors suffer from drawbacks including issues in detection sensitivity, degradation of biomaterials on the sensor's surface, and incapability to reuse the biosensors. To overcome these shortcomings, molecularly imprinted polymer nanoparticles (nanoMIPs) incorporated conductometric biosensor for highly accurate, rapid, and selective detection of two model SARS-CoV-2 proteins: (i) receptor binding domain (RBD) of the spike (S) glycoprotein and (ii) full length trimeric spike protein are introduced. In addition, these biosensors successfully responded to several other SARS-CoV-2 RBD spike protein variants including Alpha, Beta, Gamma, and Delta. Our conductometric biosensor selectively detects the two model proteins and SARS-CoV-2 RBD spike protein variant samples in real-time with sensitivity to a detection limit of 7 pg mL-1 within 10 min of sample incubation. A battery-free, wireless near-field communication (NFC) interface is incorporated with the biosensor for fast and contactless detection of SARS-CoV-2 variants. The smartphone enabled real-time detection and on-screen rapid result for SARS-CoV-2 variants can curve the outbreak due to its ability to alert the user to infection in real time.
Collapse
Affiliation(s)
- Ganganath S. Perera
- Functional Materials and Microsystems Research Group and the Micro Nano Research FacilityRMIT UniversityMelbourneVIC3001Australia
| | - Md. Ataur Rahman
- Functional Materials and Microsystems Research Group and the Micro Nano Research FacilityRMIT UniversityMelbourneVIC3001Australia
| | - April Blazevski
- Functional Materials and Microsystems Research Group and the Micro Nano Research FacilityRMIT UniversityMelbourneVIC3001Australia
| | | | - Sumeet Walia
- Functional Materials and Microsystems Research Group and the Micro Nano Research FacilityRMIT UniversityMelbourneVIC3001Australia
| | - Madhu Bhaskaran
- Functional Materials and Microsystems Research Group and the Micro Nano Research FacilityRMIT UniversityMelbourneVIC3001Australia
| | - Sharath Sriram
- Functional Materials and Microsystems Research Group and the Micro Nano Research FacilityRMIT UniversityMelbourneVIC3001Australia
| |
Collapse
|
80
|
Yuan H, Chen P, Wan C, Li Y, Liu BF. Merging microfluidics with luminescence immunoassays for urgent point-of-care diagnostics of COVID-19. Trends Analyt Chem 2022; 157:116814. [PMID: 36373139 PMCID: PMC9637550 DOI: 10.1016/j.trac.2022.116814] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 10/29/2022] [Accepted: 10/30/2022] [Indexed: 11/09/2022]
Abstract
The Coronavirus disease 2019 (COVID-19) outbreak has urged the establishment of a global-wide rapid diagnostic system. Current widely-used tests for COVID-19 include nucleic acid assays, immunoassays, and radiological imaging. Immunoassays play an irreplaceable role in rapidly diagnosing COVID-19 and monitoring the patients for the assessment of their severity, risks of the immune storm, and prediction of treatment outcomes. Despite of the enormous needs for immunoassays, the widespread use of traditional immunoassay platforms is still limited by high cost and low automation, which are currently not suitable for point-of-care tests (POCTs). Microfluidic chips with the features of low consumption, high throughput, and integration, provide the potential to enable immunoassays for POCTs, especially in remote areas. Meanwhile, luminescence detection can be merged with immunoassays on microfluidic platforms for their good performance in quantification, sensitivity, and specificity. This review introduces both homogenous and heterogenous luminescence immunoassays with various microfluidic platforms. We also summarize the strengths and weaknesses of the categorized methods, highlighting their recent typical progress. Additionally, different microfluidic platforms are described for comparison. The latest advances in combining luminescence immunoassays with microfluidic platforms for POCTs of COVID-19 are further explained with antigens, antibodies, and related cytokines. Finally, challenges and future perspectives were discussed.
Collapse
Affiliation(s)
- Huijuan Yuan
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Peng Chen
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Chao Wan
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Yiwei Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Bi-Feng Liu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| |
Collapse
|
81
|
Sinha Mahapatra P, Ganguly R, Ghosh A, Chatterjee S, Lowrey S, Sommers AD, Megaridis CM. Patterning Wettability for Open-Surface Fluidic Manipulation: Fundamentals and Applications. Chem Rev 2022; 122:16752-16801. [PMID: 36195098 DOI: 10.1021/acs.chemrev.2c00045] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Effective manipulation of liquids on open surfaces without external energy input is indispensable for the advancement of point-of-care diagnostic devices. Open-surface microfluidics has the potential to benefit health care, especially in the developing world. This review highlights the prospects for harnessing capillary forces on surface-microfluidic platforms, chiefly by inducing smooth gradients or sharp steps of wettability on substrates, to elicit passive liquid transport and higher-order fluidic manipulations without off-the-chip energy sources. A broad spectrum of the recent progress in the emerging field of passive surface microfluidics is highlighted, and its promise for developing facile, low-cost, easy-to-operate microfluidic devices is discussed in light of recent applications, not only in the domain of biomedical microfluidics but also in the general areas of energy and water conservation.
Collapse
Affiliation(s)
- Pallab Sinha Mahapatra
- Micro Nano Bio-Fluidics group, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai600036, India
| | - Ranjan Ganguly
- Department of Power Engineering, Jadavpur University, Kolkata700098, India
| | - Aritra Ghosh
- Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, Illinois60607, United States
| | - Souvick Chatterjee
- Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, Illinois60607, United States
| | - Sam Lowrey
- Department of Physics, University of Otago, Dunedin9016, New Zealand
| | - Andrew D Sommers
- Department of Mechanical and Manufacturing Engineering, Miami University, Oxford, Ohio45056, United States
| | - Constantine M Megaridis
- Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, Illinois60607, United States
| |
Collapse
|
82
|
Hang XM, Wang HY, Liu PF, Zhao KR, Wang L. Cas12a-assisted RTF-EXPAR for accurate, rapid and simple detection of SARS-CoV-2 RNA. Biosens Bioelectron 2022; 216:114683. [PMID: 36088673 PMCID: PMC9444317 DOI: 10.1016/j.bios.2022.114683] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 08/09/2022] [Accepted: 08/31/2022] [Indexed: 11/02/2022]
Abstract
Developing highly accurate and simple approaches to rapidly identify and isolate SARS-CoV-2 infected patients is important for the control of the COVID-19 pandemic. We, herein, reported the performance of a Cas12a-assisted RTF-EXPAR strategy for the identification of SARS-CoV-2 RNA. This assay combined the advantages of RTF-EXPAR with CRISPR-Cas12a can detect SARS-CoV-2 within 40 min, requiring only isothermal control. Particularly, the simultaneous use of EXPAR amplification and CRISPR improved the detection sensitivity, thereby realizing ultrasensitive SARS-CoV-2 RNA detection with a detection limit of 3.77 aM (∼2 copies/μL) in an end-point fluorescence read-out fashion, and at 4.81 aM (∼3 copies/μL) level via a smartphone-assisted analysis system (RGB analysis). Moreover, Cas12a increases the specificity by intrinsic sequence-specific template recognition. Overall, this method is fast, sensitive, and accurate, needing minimal equipment, which holds great promise to meet the requirements of point-of-care molecular detection of SARS-CoV-2.
Collapse
Affiliation(s)
- Xiao-Min Hang
- School of Pharmacy, Jiangsu University, Zhenjiang, 212013, PR China
| | - Hui-Yi Wang
- School of Pharmacy, Jiangsu University, Zhenjiang, 212013, PR China
| | - Peng-Fei Liu
- College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha, 410081, PR China
| | - Kai-Ren Zhao
- School of Pharmacy, Jiangsu University, Zhenjiang, 212013, PR China
| | - Li Wang
- School of Pharmacy, Jiangsu University, Zhenjiang, 212013, PR China.
| |
Collapse
|
83
|
Luciano K, Wang X, Liu Y, Eyler G, Qin Z, Xia X. Noble Metal Nanoparticles for Point-of-Care Testing: Recent Advancements and Social Impacts. Bioengineering (Basel) 2022; 9:666. [PMID: 36354576 PMCID: PMC9687823 DOI: 10.3390/bioengineering9110666] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 10/28/2022] [Accepted: 11/06/2022] [Indexed: 09/01/2023] Open
Abstract
Point-of-care (POC) tests for the diagnosis of diseases are critical to the improvement of the standard of living, especially for resource-limited areas or countries. In recent years, nanobiosensors based on noble metal nanoparticles (NM NPs) have emerged as a class of effective and versatile POC testing technology. The unique features of NM NPs ensure great performance of associated POC nanobiosensors. In particular, NM NPs offer various signal transduction principles, such as plasmonics, catalysis, photothermal effect, and so on. Significantly, the detectable signal from NM NPs can be tuned and optimized by controlling the physicochemical parameters (e.g., size, shape, and elemental composition) of NPs. In this article, we introduce the inherent merits of NM NPs that make them attractive for POC testing, discuss recent advancement of NM NPs-based POC tests, highlight their social impacts, and provide perspectives on challenges and opportunities in the field. We hope the review and insights provided in this article can inspire new fundamental and applied research in this emerging field.
Collapse
Affiliation(s)
- Keven Luciano
- Department of Chemistry, University of Central Florida, Orlando, FL 32816, USA
| | - Xiaochuan Wang
- School of Social Work, College of Health Professions and Sciences, University of Central Florida, Orlando, FL 32816, USA
| | - Yaning Liu
- Department of Mechanical Engineering, University of Texas at Dallas, Richardson, TX 75080, USA
| | - Gabriella Eyler
- School of Social Work, College of Health Professions and Sciences, University of Central Florida, Orlando, FL 32816, USA
| | - Zhenpeng Qin
- Department of Mechanical Engineering, University of Texas at Dallas, Richardson, TX 75080, USA
- Department of Bioengineering, Center for Advanced Pain Studies, University of Texas at Dallas, Richardson, TX 75080, USA
- Department of Surgery, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Xiaohu Xia
- Department of Chemistry, University of Central Florida, Orlando, FL 32816, USA
| |
Collapse
|
84
|
Dual-mode visual detection strategies of viable pathogens for point-of-care testing. Biosens Bioelectron 2022; 221:114904. [DOI: 10.1016/j.bios.2022.114904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 10/31/2022] [Accepted: 11/08/2022] [Indexed: 11/13/2022]
|
85
|
Photoacoustic detection of SARS-CoV-2 spike N501Y single-nucleotide polymorphism based on branched rolling circle amplification. Talanta 2022. [PMCID: PMC9630300 DOI: 10.1016/j.talanta.2022.124047] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Rapid and accurate diagnosis of SARS-CoV-2 single-nucleotide variations is an urgent need for the initial detection of local circulation and monitoring the alternation of dominant variant. In this proof-of-concept study, a homogeneous and isothermal photoacoustic biosensor is demonstrated for rapid molecular amplification and detection of a synthetic DNA corresponding to SARS-CoV-2 spike N501Y. Branched rolling circle amplification produces single-stranded amplicons that can aggregate detection probe-modified AuNPs, which induces a strong photoacoustic signal at 640 nm due to both the surface plasmon resonance shift and the size-dependent effect of laser-induced nanobubbles, achieving a sub-femtomolar detection limit within a total assay time of 80 min. The limit of detection can be kept when measuring 5% serum samples. Moreover, the proposed biosensor is highly specific for single-nucleotide polymorphism discrimination and robust against background DNA.
Collapse
|
86
|
Ganesh PS, Kim SY. A comparison of conventional and advanced electroanalytical methods to detect SARS-CoV-2 virus: A concise review. CHEMOSPHERE 2022; 307:135645. [PMID: 35817176 PMCID: PMC9270057 DOI: 10.1016/j.chemosphere.2022.135645] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 07/04/2022] [Accepted: 07/05/2022] [Indexed: 06/15/2023]
Abstract
Respiratory viruses are a serious threat to human wellbeing that can cause pandemic disease. As a result, it is critical to identify virus in a timely, sensitive, and precise manner. The present novel coronavirus-2019 (COVID-19) disease outbreak has increased these concerns. The research of developing various methods for COVID-19 virus identification is one of the most rapidly growing research areas. This review article compares and addresses recent improvements in conventional and advanced electroanalytical approaches for detecting COVID-19 virus. The popular conventional methods such as polymerase chain reaction (PCR), loop mediated isothermal amplification (LAMP), serology test, and computed tomography (CT) scan with artificial intelligence require specialized equipment, hours of processing, and specially trained staff. Many researchers, on the other hand, focused on the invention and expansion of electrochemical and/or bio sensors to detect SARS-CoV-2, demonstrating that they could show a significant role in COVID-19 disease control. We attempted to meticulously summarize recent advancements, compare conventional and electroanalytical approaches, and ultimately discuss future prospective in the field. We hope that this review will be helpful to researchers who are interested in this interdisciplinary field and desire to develop more innovative virus detection methods.
Collapse
Affiliation(s)
- Pattan-Siddappa Ganesh
- Interaction Laboratory, Advanced Technology Research Center, Future Convergence Engineering, Korea University of Technology and Education (KoreaTech), Cheonan-si, Chungcheongnam-do, 330-708, Republic of Korea.
| | - Sang-Youn Kim
- Interaction Laboratory, Advanced Technology Research Center, Future Convergence Engineering, Korea University of Technology and Education (KoreaTech), Cheonan-si, Chungcheongnam-do, 330-708, Republic of Korea.
| |
Collapse
|
87
|
Li P, Xiong H, Yang B, Jiang X, Kong J, Fang X. Recent progress in CRISPR-based microfluidic assays and applications. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
88
|
Euliano EM, Sklavounos AA, Wheeler AR, McHugh KJ. Translating diagnostics and drug delivery technologies to low-resource settings. Sci Transl Med 2022; 14:eabm1732. [PMID: 36223447 PMCID: PMC9716722 DOI: 10.1126/scitranslmed.abm1732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
Diagnostics and drug delivery technologies engineered for low-resource settings aim to meet their technical design specifications using strategies that are compatible with limited equipment, infrastructure, and operator training. Despite many preclinical successes, very few of these devices have been translated to the clinic. Here, we identify factors that contribute to the clinical success of diagnostics and drug delivery systems for low-resource settings, including the need to engage key stakeholders at an early stage, and provide recommendations for the clinical translation of future medical technologies.
Collapse
Affiliation(s)
- Erin M. Euliano
- Department of Bioengineering, Rice University; Houston, Texas 77005, USA
| | - Alexandros A. Sklavounos
- Department of Chemistry, University of Toronto; Toronto, Ontario M5S 3H6, Canada
- Donnelly Centre for Cellular and Biomolecular Research, University of Toronto; Toronto, Ontario M5S 3E1, Canada
| | - Aaron R. Wheeler
- Department of Chemistry, University of Toronto; Toronto, Ontario M5S 3H6, Canada
- Donnelly Centre for Cellular and Biomolecular Research, University of Toronto; Toronto, Ontario M5S 3E1, Canada
- Institute of Biomedical Engineering, University of Toronto; Toronto, Ontario M5S 3G9, Canada
| | - Kevin J. McHugh
- Department of Bioengineering, Rice University; Houston, Texas 77005, USA
| |
Collapse
|
89
|
Development and application of a recombinase-aided amplification and lateral flow assay for rapid detection of pseudorabies virus from clinical crude samples. Int J Biol Macromol 2022; 224:646-652. [DOI: 10.1016/j.ijbiomac.2022.10.153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 10/11/2022] [Accepted: 10/17/2022] [Indexed: 11/05/2022]
|
90
|
Vicentini FC, Silva LRG, Stefano JS, Lima ARF, Prakash J, Bonacin JA, Janegitz BC. Starch-Based Electrochemical Sensors and Biosensors: A Review. BIOMEDICAL MATERIALS & DEVICES 2022. [PMCID: PMC9510496 DOI: 10.1007/s44174-022-00012-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Natural green compounds for sensor modification (binders) are challenging in electrochemistry. Starch is a carbohydrate biopolymer that has been used extensively in the development of biomaterials for the food industry due to its ability to impart textural characteristics and provide gelling or film formation. In particular, the excellent film-forming characteristics have been used for the development of new surface modifying architectures for electrodes. Here, we highlight a very comprehensive overview of the properties of interest of various types of starch in conjunction with (bio)materials in the chemical modification of sensors and biosensors. Throughout the review, we first give an introduction to the extraction, applications, and properties of starches followed by an overview of the prospects and their possible applications in electrochemical sensors and biosensors. In this context, we discuss some important characteristics of starches and different strategies of their film formation with an emphasis on their role in the development of electrochemical sensors and biosensors highlighting their main contributions to enhancing the performance of these devices and their applications in environmental and clinical samples.
Collapse
Affiliation(s)
- Fernando C. Vicentini
- Center of Nature Sciences, Federal University of São Carlos, Rod. Lauri Simões de Barros km 12, Buri, SP 18290-000 Brazil
| | - Luiz R. G. Silva
- Laboratory of Sensors, Nanomedicine, and Nanostructured Materials (LSNano), Federal University of São Carlos, Araras, São Paulo 13600-970 Brazil
| | - Jéssica S. Stefano
- Laboratory of Sensors, Nanomedicine, and Nanostructured Materials (LSNano), Federal University of São Carlos, Araras, São Paulo 13600-970 Brazil
| | - Alan R. F. Lima
- Center of Nature Sciences, Federal University of São Carlos, Rod. Lauri Simões de Barros km 12, Buri, SP 18290-000 Brazil
| | - Jai Prakash
- Department of Chemistry, National Institute of Technology Hamirpur, Hamirpur, Himachal Pradesh 177005 India
| | - Juliano A. Bonacin
- Institute of Chemistry, University of Campinas (UNICAMP), Campinas, São Paulo 13083-859 Brazil
| | - Bruno C. Janegitz
- Laboratory of Sensors, Nanomedicine, and Nanostructured Materials (LSNano), Federal University of São Carlos, Araras, São Paulo 13600-970 Brazil
| |
Collapse
|
91
|
Miniaturized Real-Time PCR systems for SARS-CoV-2 detection at the Point-of-Care. Clin Chim Acta 2022; 536:104-111. [PMID: 36126763 PMCID: PMC9482443 DOI: 10.1016/j.cca.2022.09.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 09/08/2022] [Accepted: 09/12/2022] [Indexed: 12/12/2022]
Abstract
Over the past two years, SARS-CoV-2 (Severe Acute Respiratory Syndrome-Coronavirus 2) infection has spread globally causing multi-organ disease and severely impacting the healthcare systems of all countries. Accordingly, the development of easy-to-access diagnostic devices has become essential to limit the effect of the virus worldwide. Real-Time PCR is considered the gold standard to identify SARS-CoV-2 infection due to high sensitivity, affordability, and capacity to detect low viral loads at early disease stage. Advances in lab on a chip technology has led to the development of some Point-of-Care (POC) devices using Real-Time PCR and approved by the United States Food and Drug Administration. We provide an overview on recently developed POC tests for the rapid diagnosis of COVID-19 infection. Practical applications of miniaturized devices based on viral genome amplification as well as favorable features such as reduced sample processing time, ease of use by non-specialized personnel, and the potential of PCR-based POC technologies will be highlighted and reviewed.
Collapse
|
92
|
Jonguitud-Borrego N, Malcı K, Anand M, Baluku E, Webb C, Liang L, Barba-Ostria C, Guaman LP, Hui L, Rios-Solis L. High—throughput and automated screening for COVID-19. FRONTIERS IN MEDICAL TECHNOLOGY 2022; 4:969203. [PMID: 36188187 PMCID: PMC9521367 DOI: 10.3389/fmedt.2022.969203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Accepted: 08/29/2022] [Indexed: 11/13/2022] Open
Abstract
The COVID-19 pandemic has become a global challenge for the healthcare systems of many countries with 6 million people having lost their lives and 530 million more having tested positive for the virus. Robust testing and a comprehensive track and trace process for positive patients are essential for effective pandemic control, leading to high demand for diagnostic testing. In order to comply with demand and increase testing capacity worldwide, automated workflows have come into prominence as they enable high-throughput screening, faster processing, exclusion of human error, repeatability, reproducibility and diagnostic precision. The gold standard for COVID-19 testing so far has been RT-qPCR, however, different SARS-CoV-2 testing methods have been developed to be combined with high throughput testing to improve diagnosis. Case studies in China, Spain and the United Kingdom have been reviewed and automation has been proven to be promising for mass testing. Free and Open Source scientific and medical Hardware (FOSH) plays a vital role in this matter but there are some challenges to be overcome before automation can be fully implemented. This review discusses the importance of automated high-throughput testing, the different equipment available, the bottlenecks of its implementation and key selected case studies that due to their high effectiveness are already in use in hospitals and research centres.
Collapse
Affiliation(s)
- Nestor Jonguitud-Borrego
- Institute for Bioengineering, School of Engineering, The University of Edinburgh, Edinburgh, United Kingdom
- Centre for Synthetic and Systems Biology (SynthSys), The University of Edinburgh, Edinburgh, United Kingdom
| | - Koray Malcı
- Institute for Bioengineering, School of Engineering, The University of Edinburgh, Edinburgh, United Kingdom
- Centre for Synthetic and Systems Biology (SynthSys), The University of Edinburgh, Edinburgh, United Kingdom
| | - Mihir Anand
- School of Biochemical Engineering, Indian Institute of Technology BHU, Varanasi, India
| | - Erikan Baluku
- School of Bio-Security, Biotechnical and Laboratory Sciences Makerere University, Kampala, Uganda
| | - Calum Webb
- Institute for Bioengineering, School of Engineering, The University of Edinburgh, Edinburgh, United Kingdom
| | - Lungang Liang
- BGI Clinical Laboratories, BGI-Shenzhen, Shenzhen, China
| | - Carlos Barba-Ostria
- Escuela de Medicina, Colegio de Ciencias de la Salud Quito, Universidad San Francisco de Quito USFQ, Quito, Ecuador
| | - Linda P. Guaman
- Centro de Investigación Biomédica (CENBIO), Facultad de Ciencias de la Salud Eugenio Espejo, Universidad UTE, Quito, Ecuador
| | - Liu Hui
- BGI Clinical Laboratories, BGI-Shenzhen, Shenzhen, China
| | - Leonardo Rios-Solis
- Institute for Bioengineering, School of Engineering, The University of Edinburgh, Edinburgh, United Kingdom
- Centre for Synthetic and Systems Biology (SynthSys), The University of Edinburgh, Edinburgh, United Kingdom
- School of Natural and Environmental Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom
- Correspondence: Leonardo Rios-Solis
| |
Collapse
|
93
|
Zai Y, Min C, Wang Z, Ding Y, Zhao H, Su E, He N. A sample-to-answer, quantitative real-time PCR system with low-cost, gravity-driven microfluidic cartridge for rapid detection of SARS-CoV-2, influenza A/B, and human papillomavirus 16/18. LAB ON A CHIP 2022; 22:3436-3452. [PMID: 35972195 DOI: 10.1039/d2lc00434h] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The pandemic of coronavirus disease 2019 (COVID-19), due to the novel coronavirus (SARS-CoV-2), has created an unprecedented threat to the global health system, especially in resource-limited areas. This challenge shines a spotlight on the urgent need for a point-of-care (POC) quantitative real-time PCR (qPCR) test for sensitive and rapid diagnosis of viral infections. In a POC system, a closed, single-use, microfluidic cartridge is commonly utilized for integration of nucleic acid preparation, PCR amplification and florescence detection. But, most current cartridge systems often involve complicated nucleic acid extraction via active pumping that relies on cumbersome external hardware, causing increases in system complexity and cost. In this work, we demonstrate a gravity-driven cartridge design for an integrated viral RNA/DNA diagnostic test that does not require auxiliary hardware for fluid pumping due to adopted extraction-free amplification. This microfluidic cartridge only contains two reaction chambers for nucleic acid lysis and amplification respectively, enabling a fast qPCR test in less than 30 min. This gravity-driven pumping strategy can help simplify and minimize the microfluidic cartridge, thus enabling high-throughput (up to 12 test cartridges per test) molecular detection via a small cartridge readout system. Thus, this work addresses the scalability limitation of POC molecular testing and can be run in any settings. We verified the analytical sensitivity and specificity of the cartridge testing for respiratory pathogens and sexually transmitted diseases using SARS-CoV-2, influenza A/B RNA samples, and human papillomavirus 16/18 DNA samples. Our cartridge system exhibited a comparable detection performance to the current gold standard qPCR instrument ABI 7500. Moreover, our system showed very high diagnostic accuracy for viral RNA/DNA detection that was well validated by ROC curve analysis. The sample-to-answer molecular testing system reported in this work has the advantages of simplicity, rapidity, and low cost, making it highly promising for prevention and control of infectious diseases in poor-resource areas.
Collapse
Affiliation(s)
- Yunfeng Zai
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Si Pai Lou 2, Nanjing 210096, China.
- Getein Biotechnology Co., Ltd., Nanjing 210000, China.
| | - Chao Min
- Getein Biotechnology Co., Ltd., Nanjing 210000, China.
| | - Zunliang Wang
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Si Pai Lou 2, Nanjing 210096, China.
| | - Yongjun Ding
- Getein Biotechnology Co., Ltd., Nanjing 210000, China.
| | - Huan Zhao
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Si Pai Lou 2, Nanjing 210096, China.
- Getein Biotechnology Co., Ltd., Nanjing 210000, China.
| | - Enben Su
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Si Pai Lou 2, Nanjing 210096, China.
- Getein Biotechnology Co., Ltd., Nanjing 210000, China.
| | - Nongyue He
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Si Pai Lou 2, Nanjing 210096, China.
| |
Collapse
|
94
|
Özkul G, Kehribar EŞ, Ahan RE, Köksaldı İÇ, Özkul A, Dinç B, Aydoğan S, Şeker UÖŞ. A Genetically Engineered Biofilm Material for SARS-CoV-2 Capturing and Isolation. ADVANCED MATERIALS INTERFACES 2022; 9:2201126. [PMID: 36248312 PMCID: PMC9538133 DOI: 10.1002/admi.202201126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 08/10/2022] [Indexed: 06/16/2023]
Abstract
The novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is continuously infecting people all around the world since its outbreak in 2019. Studies for numerous infection detection strategies are continuing. The sensitivity of detection methods is crucial to separate people with mild infections from people who are asymptomatic. In this sense, a strategy that would help to capture and isolate the SARS-CoV-2 virus prior to tests can be effective and beneficial. To this extent, genetically engineered biomaterials grounding from the biofilm protein of Escherichia coli are beneficial due to their robustness and adaptability to various application areas. Through functionalizing the E. coli biofilm protein, diverse properties can be attained such as enzyme display, nanoparticle production, and medical implant structures. Here, E. coli species are employed to express major curli protein CsgA and Griffithsin (GRFT) as fusion proteins, through a complex formation using SpyTag and SpyCatcher domains. In this study, a complex system with a CsgA scaffold harboring the affinity of GRFT against Spike protein to capture and isolate SARS-CoV-2 virus is successfully developed. It is shown that the hybrid recombinant protein can dramatically increase the sensitivity of currently available lateral flow assays for Sars-CoV-2 diagnostics.
Collapse
Affiliation(s)
- Gökçe Özkul
- UNAM ‐ Institute of Materials Science and NanotechnologyBilkent UniversityAnkara06800Turkey
| | - Ebru Şahin Kehribar
- UNAM ‐ Institute of Materials Science and NanotechnologyBilkent UniversityAnkara06800Turkey
| | - Recep Erdem Ahan
- UNAM ‐ Institute of Materials Science and NanotechnologyBilkent UniversityAnkara06800Turkey
| | - İlkay Çisil Köksaldı
- UNAM ‐ Institute of Materials Science and NanotechnologyBilkent UniversityAnkara06800Turkey
| | - Aykut Özkul
- Department of VirologyFaculty of Veterinary MedicineAnkara UniversityDışkapıAnkara06110Turkey
| | - Bedia Dinç
- Medical Microbiology Laboratory and Department of Clinical Microbiology and Infectious DiseasesAnkara Bilkent City HospitalHealth Sciences UniversityAnkara06800Turkey
| | - Sibel Aydoğan
- Medical Microbiology Laboratory and Department of Clinical Microbiology and Infectious DiseasesAnkara Bilkent City HospitalHealth Sciences UniversityAnkara06800Turkey
| | | |
Collapse
|
95
|
Fang Y, Wang Y, Su X, Liu H, Chen H, Chen Z, Jin L, He N. A miniaturized and integrated dual-channel fluorescence module for multiplex real-time PCR in the portable nucleic acid detection system. Front Bioeng Biotechnol 2022; 10:996456. [PMID: 36172017 PMCID: PMC9510591 DOI: 10.3389/fbioe.2022.996456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2022] [Accepted: 08/29/2022] [Indexed: 11/13/2022] Open
Abstract
A portable nucleic acid detection (PNAD) system based on real-time polymerase chain reaction (real-time PCR) has been developed for point-of-care testing (POCT) of infectious disease pathogens. In order to achieve “sample-in, result-out” while keeping the system compact, the hardware system integrates optical, thermal and motion control modules in a limited space for nucleic acid extraction, purification, amplification and detection. Among these hardware modules, the fluorescence module is one of the most important modules, because its performance directly affects the accuracy and sensitivity of the testing results. In this paper, a miniaturized, high-sensitivity and integrated dual-channel fluorescence module have been proposed for the homemade PNAD system. Based on the principle of confocal optical path, two group of excitation-emission optical paths of different wavelengths are integrated in a small space. In terms of circuitry, a current-light dual negative feedback light emitting diode (LED) drive circuit is applied to improve the stability of the excited light source. All optical and electronic components are integrated in a metal box of 55 mm × 45 mm × 15 mm, that helps miniaturize the detection system. Two different modules have been assembled to fit various fluorescent dyes or probes with the set of excitation and emission as follow: module 1#: 470 nm/525 nm, 570 nm/630 nm; module 2#: 520 nm/570 nm, 630 nm/690 nm. Finally, hepatitis B virus (HBV) concentration gradient detection and multiplex detection of different gene targets of SARS-CoV-2 are carried out on the PNAD system equipped with these two fluorescence modules for evaluating their performances. Compared with the commercial real-time PCR instrument, our fluorescence module has good stability and detection sensitivity.
Collapse
Affiliation(s)
- Yile Fang
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
| | - Yue Wang
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
| | - Xiangyi Su
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
| | - Haoran Liu
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
| | - Hui Chen
- Economical Forest Cultivation and Utilization of 2011 Collaborative Innovation Center in Hunan Province, Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Zhu Chen
- Economical Forest Cultivation and Utilization of 2011 Collaborative Innovation Center in Hunan Province, Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Lian Jin
- Economical Forest Cultivation and Utilization of 2011 Collaborative Innovation Center in Hunan Province, Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
| | - Nongyue He
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
- Economical Forest Cultivation and Utilization of 2011 Collaborative Innovation Center in Hunan Province, Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China
- *Correspondence: Nongyue He,
| |
Collapse
|
96
|
Bordbar MM, Samadinia H, Sheini A, Aboonajmi J, Hashemi P, Khoshsafar H, Halabian R, Khanmohammadi A, Nobakht M Gh BF, Sharghi H, Ghanei M, Bagheri H. Visual diagnosis of COVID-19 disease based on serum metabolites using a paper-based electronic tongue. Anal Chim Acta 2022; 1226:340286. [PMID: 36068068 PMCID: PMC9393192 DOI: 10.1016/j.aca.2022.340286] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 08/05/2022] [Accepted: 08/17/2022] [Indexed: 12/12/2022]
Abstract
This study aims to use a paper-based sensor array for point-of-care detection of COVID-19 diseases. Various chemical compounds such as nanoparticles, organic dyes and metal ion complexes were employed as sensing elements in the array fabrication, capturing the metabolites of human serum samples. The viral infection caused the type and concentration of serum compositions to change, resulting in different color responses for the infected and control samples. For this purpose, 118 serum samples of COVID-19 patients and non-COVID controls both men and women with the age range of 14–88 years were collected. The serum samples were initially subjected to the sensor, followed by monitoring the variation in the color of sensing elements for 5 min using a scanner. By taking into consideration the statistical information, this method was capable of discriminating COVID-19 patients and control samples with 83.0% accuracy. The variation of age did not influence the colorimetric patterns. The desirable correlation was observed between the sensor responses and viral load values calculated by the PCR test, proposing a rapid and facile way to estimate the disease severity. Compared to other rapid detection methods, the developed assay is cost-effective and user-friendly, allowing for screening COVID-19 diseases reliably.
Collapse
Affiliation(s)
- Mohammad Mahdi Bordbar
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Hosein Samadinia
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Azarmidokht Sheini
- Department of Mechanical Engineering, Shohadaye Hoveizeh Campus of Technology, Shahid Chamran University of Ahvaz, Dashte Azadegan, Khuzestan, Iran
| | - Jasem Aboonajmi
- Department of Chemistry, College of Sciences, Shiraz University, Shiraz, Iran
| | - Pegah Hashemi
- Research and Development Department, Farin Behbood Tashkhis LTD, Tehran, Iran
| | - Hosein Khoshsafar
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Raheleh Halabian
- Applied Microbiology Research Center, Systems Biology and Poising Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Akbar Khanmohammadi
- Research and Development Department, Farin Behbood Tashkhis LTD, Tehran, Iran
| | - B Fatemeh Nobakht M Gh
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Hashem Sharghi
- Department of Chemistry, College of Sciences, Shiraz University, Shiraz, Iran
| | - Mostafa Ghanei
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Hasan Bagheri
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
97
|
Torezin Mendonça G, Cassaboni Stracke M, de Oliveira Coelho B, Bruna Soligo Sanchuki H, Klassen de Oliveira V, Klerynton Marchini F, Lucíola Zanette D, Nóbrega Aoki M, Ribeiro Viana E, Blanes L. A new RT-LAMP-on-a-Chip Instrument for SARS-CoV-2 diagnostics. Microchem J 2022; 180:107600. [PMID: 35620142 PMCID: PMC9121651 DOI: 10.1016/j.microc.2022.107600] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Revised: 05/13/2022] [Accepted: 05/14/2022] [Indexed: 02/08/2023]
Abstract
This work describes the development of a Point-of-Care (POC) Lab-on-a-Chip (LOC) instrument for diagnosis of SARS-CoV-2 by Reverse-Transcription Loop-mediated isothermal amplification (RT-LAMP). The hardware is based on a Raspberry Pi computer ($35), a video camera, an Arduino Nano microcontroller, a printed circuit board as a heater and a 3D printed housing. The chips were manufactured in polymethyl methacrylate (PMMA) using a CO2 laser cutting machine and sealed with a PCR optic plastic film. The chip temperature is precisely controlled by a proportional-integral-derivative (PID) algorithm. During the RT-LAMP amplifications the chip was maintained at ∼ (65.0 ± 0.1) °C for 25 minutes and 5 minutes cooling down, totaling a 30 minutes of reaction .The software interpretation occurs in less than a second. The chip design has four 25 µL chambers, two for clinical samples and two for positive and negative control-samples. The RT-LAMP master mix solution added in the chip chambers contains the pH indicator Phenol Red, that is pink (for pH ∼ 8.0) before amplification and becomes yellow (pH ∼ 6.0) if the genetic material is amplified. The RT-LAMP SARS-CoV-2 diagnostic was made by color image recognition using the OpenCV machine vision software library. The software was programmed to automatically distinguish the HSV color parameter distribution in each one of the four chip chambers. The instrument was successfully tested for SARS-CoV-2 diagnosis, in 22 clinic samples, 11 positives and 11 negatives, achieving an assertiveness of 86% when compared to the results obtained by RT-LAMP standard reactions performed in conventional PCR equipment.
Collapse
Affiliation(s)
- Geovani Torezin Mendonça
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil
| | - Mateus Cassaboni Stracke
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil,Paraná Institute of Molecular Biology, Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil
| | - Bruna de Oliveira Coelho
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil
| | - Heloisa Bruna Soligo Sanchuki
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil
| | | | - Fabricio Klerynton Marchini
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil,Paraná Institute of Molecular Biology, Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil
| | - Dalila Lucíola Zanette
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil
| | - Mateus Nóbrega Aoki
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil
| | - Emilson Ribeiro Viana
- Research and Characterization of Nanomaterials and Nanodevices Laboratory (LPCA-NN), Physics Department, Federal University of Technology - Paraná, 7 de setembro 3165 Avenue, Curitiba, Paraná, Brazil
| | - Lucas Blanes
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil,Paraná Institute of Molecular Biology, Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil,Corresponding author
| |
Collapse
|
98
|
Abdul Ghani MA, Nordin AN, Zulhairee M, Che Mohamad Nor A, Shihabuddin Ahmad Noorden M, Muhamad Atan MKF, Ab Rahim R, Mohd Zain Z. Portable Electrochemical Biosensors Based on Microcontrollers for Detection of Viruses: A Review. BIOSENSORS 2022; 12:666. [PMID: 36005062 PMCID: PMC9406062 DOI: 10.3390/bios12080666] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 08/17/2022] [Accepted: 08/18/2022] [Indexed: 02/07/2023]
Abstract
With the rise of zoonotic diseases in recent years, there is an urgent need for improved and more accessible screening and diagnostic methods to mitigate future outbreaks. The recent COVID-19 pandemic revealed an over-reliance on RT-PCR, a slow, costly and lab-based method for diagnostics. To better manage the pandemic, a high-throughput, rapid point-of-care device is needed for early detection and isolation of patients. Electrochemical biosensors offer a promising solution, as they can be used to perform on-site tests without the need for centralized labs, producing high-throughput and accurate measurements compared to rapid test kits. In this work, we detail important considerations for the use of electrochemical biosensors for the detection of respiratory viruses. Methods of enhancing signal outputs via amplification of the analyte, biorecognition of elements and modification of the transducer are also explained. The use of portable potentiostats and microfluidics chambers that create a miniature lab are also discussed in detail as an alternative to centralized laboratory settings. The state-of-the-art usage of portable potentiostats for detection of viruses is also elaborated and categorized according to detection technique: amperometry, voltammetry and electrochemical impedance spectroscopy. In terms of integration with microfluidics, RT-LAMP is identified as the preferred method for DNA amplification virus detection. RT-LAMP methods have shorter turnaround times compared to RT-PCR and do not require thermal cycling. Current applications of RT-LAMP for virus detection are also elaborated upon.
Collapse
Affiliation(s)
- Muhammad Afiq Abdul Ghani
- MEMS-VLSI Research Unit, Department of Electrical and Computer Engineering, Engineering Faculty, International Islamic University Malaysia, Kuala Lumpur 53100, Federal Territory of Kuala Lumpur, Malaysia
| | - Anis Nurashikin Nordin
- MEMS-VLSI Research Unit, Department of Electrical and Computer Engineering, Engineering Faculty, International Islamic University Malaysia, Kuala Lumpur 53100, Federal Territory of Kuala Lumpur, Malaysia
| | - Munirah Zulhairee
- Electrochemical Material and Sensor (EMaS) Research Group, Faculty of Applied Sciences, Universiti Teknologi MARA, Shah Alam 40450, Selangor, Malaysia
| | - Adibah Che Mohamad Nor
- Faculty of Pharmacy, Universiti Teknologi MARA, Puncak Alam Campus, Bandar Puncak Alam 42300, Selangor, Malaysia
| | | | - Muhammad Khairul Faisal Muhamad Atan
- MEMS-VLSI Research Unit, Department of Electrical and Computer Engineering, Engineering Faculty, International Islamic University Malaysia, Kuala Lumpur 53100, Federal Territory of Kuala Lumpur, Malaysia
| | - Rosminazuin Ab Rahim
- MEMS-VLSI Research Unit, Department of Electrical and Computer Engineering, Engineering Faculty, International Islamic University Malaysia, Kuala Lumpur 53100, Federal Territory of Kuala Lumpur, Malaysia
| | - Zainiharyati Mohd Zain
- Electrochemical Material and Sensor (EMaS) Research Group, Faculty of Applied Sciences, Universiti Teknologi MARA, Shah Alam 40450, Selangor, Malaysia
| |
Collapse
|
99
|
Ye Q, Zhang Z, Liu J, Wang X. Screen-printed electrode-based biosensors modified with functional nucleic acid probes and their applications in this pandemic age: a review. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:2961-2975. [PMID: 35913361 DOI: 10.1039/d2ay00666a] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Electrochemical methodology has probably been the most used sensing platform in the past few years as they provide superior advantages. In particular, screen-printed electrode (SPE)-based sensing applications stand out as they provide extraordinary miniaturized but robust and user-friendly detection system. In this context, we are focusing on the modification of SPE with functional nucleic acid probes and nanostructures to improve the electrochemical detection performance in versatile sensing applications, particularly in the fight against the COVID-19 pandemic. Aptamers are immobilized on the electrode surface to detect non-nucleic acid targets and complementary probes to recognize and capture nucleic acid targets. In a step further, SPE-based biosensors with the modification of self-assembled DNA nanostructures are emphasized as they offer great potential for the interface engineering of the electrode surface and promote the excellent performance of various interface reactions. By equipping with a portable potentiostat and a smartphone monitoring device, the realization of this SPE-based miniaturized diagnostic system for the further requirement of fast and POC detection is revealed. Finally, more novel and excellent works are previewed and future perspectives in this field are mentioned.
Collapse
Affiliation(s)
- Qingqing Ye
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| | - Zhenqi Zhang
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| | - Jian Liu
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| | - Xuyao Wang
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| |
Collapse
|
100
|
Rajsri KS, McRae MP, Simmons GW, Christodoulides NJ, Matz H, Dooley H, Koide A, Koide S, McDevitt JT. A Rapid and Sensitive Microfluidics-Based Tool for Seroprevalence Immunity Assessment of COVID-19 and Vaccination-Induced Humoral Antibody Response at the Point of Care. BIOSENSORS 2022; 12:621. [PMID: 36005017 PMCID: PMC9405565 DOI: 10.3390/bios12080621] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Revised: 08/05/2022] [Accepted: 08/06/2022] [Indexed: 12/14/2022]
Abstract
As of 8 August 2022, SARS-CoV-2, the causative agent of COVID-19, has infected over 585 million people and resulted in more than 6.42 million deaths worldwide. While approved SARS-CoV-2 spike (S) protein-based vaccines induce robust seroconversion in most individuals, dramatically reducing disease severity and the risk of hospitalization, poorer responses are observed in aged, immunocompromised individuals and patients with certain pre-existing health conditions. Further, it is difficult to predict the protection conferred through vaccination or previous infection against new viral variants of concern (VoC) as they emerge. In this context, a rapid quantitative point-of-care (POC) serological assay able to quantify circulating anti-SARS-CoV-2 antibodies would allow clinicians to make informed decisions on the timing of booster shots, permit researchers to measure the level of cross-reactive antibody against new VoC in a previously immunized and/or infected individual, and help assess appropriate convalescent plasma donors, among other applications. Utilizing a lab-on-a-chip ecosystem, we present proof of concept, optimization, and validation of a POC strategy to quantitate COVID-19 humoral protection. This platform covers the entire diagnostic timeline of the disease, seroconversion, and vaccination response spanning multiple doses of immunization in a single POC test. Our results demonstrate that this platform is rapid (~15 min) and quantitative for SARS-CoV-2-specific IgG detection.
Collapse
Affiliation(s)
- Kritika Srinivasan Rajsri
- Department of Molecular Pathobiology, Division of Biomaterials, Bioengineering Institute, New York University College of Dentistry, New York, NY 10010, USA
- Vilcek Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, NY 10016, USA
| | - Michael P. McRae
- Department of Molecular Pathobiology, Division of Biomaterials, Bioengineering Institute, New York University College of Dentistry, New York, NY 10010, USA
| | - Glennon W. Simmons
- Department of Molecular Pathobiology, Division of Biomaterials, Bioengineering Institute, New York University College of Dentistry, New York, NY 10010, USA
| | - Nicolaos J. Christodoulides
- Department of Molecular Pathobiology, Division of Biomaterials, Bioengineering Institute, New York University College of Dentistry, New York, NY 10010, USA
| | - Hanover Matz
- Department of Microbiology and Immunology, Institute of Marine and Environmental Technology, University of Maryland School of Medicine, Baltimore, MD 21202, USA
| | - Helen Dooley
- Department of Microbiology and Immunology, Institute of Marine and Environmental Technology, University of Maryland School of Medicine, Baltimore, MD 21202, USA
| | - Akiko Koide
- Department of Medicine, NYU Grossman School of Medicine, New York, NY 10016, USA
| | - Shohei Koide
- Department of Biochemistry and Molecular Pharmacology, NYU Grossman School of Medicine, New York, NY 10016, USA
| | - John T. McDevitt
- Department of Molecular Pathobiology, Division of Biomaterials, Bioengineering Institute, New York University College of Dentistry, New York, NY 10010, USA
- Department of Chemical and Biomolecular Engineering, NYU Tandon School of Engineering, Brooklyn, NY 11201, USA
| |
Collapse
|