51
|
Fogelson SB, Camus AC, Lorenz W, Phillips A, Bartlett P, Sanchez S. Mycobacterium syngnathidarum sp. nov., a rapidly growing mycobacterium identified in syngnathid fish. Int J Syst Evol Microbiol 2018; 68:3696-3700. [PMID: 30272539 DOI: 10.1099/ijsem.0.002978] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
Two closely related isolates, 27335T and 24999, of rapidly growing, non-pigmented mycobacteria, were cultured from two clinically ill fish of the family Syngnathidae. Whole genome sequencing of the two isolates revealed low sequence homology to documented mycobacteria within public databases such as the NCBI. Evaluation of targeted housekeeping genes, including 16S rRNA, ITS, rpoB and hsp65, related the two bacteria distantly to Mycobacterium senegalense CK2 M4421 and Mycobacterium farcinogenes DSM 43637. Phenotypic, biochemical and dDNA-DNA hybridization tests demonstrated that Mycobacterium syngnathidarum is a new species distinct from other recognized rapidly growing mycobacterial species. Phenotypic, chemotaxonomic and phylogenetic data evaluation provided evidence that the two strains represent one novel species. We propose the formal recognition of Mycobacterium syngnathidarum sp. nov., with isolate 27335T as the type strain (=ATCC TSD-89T,=DSM 105112T).
Collapse
Affiliation(s)
- Susan B Fogelson
- 1Department of Pathology, University of Georgia, College of Veterinary Medicine, Athens, GA, USA
| | - Alvin C Camus
- 1Department of Pathology, University of Georgia, College of Veterinary Medicine, Athens, GA, USA
| | - Walt Lorenz
- 2University of Georgia, Institute of Bioinformatics, Athens, GA, USA
| | - Ashley Phillips
- 3Department of Infectious Diseases, University of Georgia, College of Veterinary Medicine, Athens, GA, USA
| | - Paula Bartlett
- 3Department of Infectious Diseases, University of Georgia, College of Veterinary Medicine, Athens, GA, USA
| | - Susan Sanchez
- 3Department of Infectious Diseases, University of Georgia, College of Veterinary Medicine, Athens, GA, USA
| |
Collapse
|
52
|
Antimycobacterial potential of the juniper berry essential oil in tap water. Arh Hig Rada Toksikol 2018; 69:46-54. [PMID: 29604199 DOI: 10.2478/aiht-2018-69-3085] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2017] [Accepted: 03/01/2018] [Indexed: 11/20/2022] Open
Abstract
Mycobacterium avium complex-related diseases are often associated with poorly maintained hot water systems. This calls for the development of new control strategies. The aim of this study was to investigate the activity of essential oils (EOs) from the Mediterranean plants, common juniper, immortelle, sage, lavandin, laurel, and white cedar against Mycobacterium avium ssp. avium, Mycobacterium intracellulare, and Mycobacterium gordonae in culturing broth and freshwater as their most common habitat. To do that, we developed a new method of water microdilution to determine their minimal effective concentrations (MEC). The most active EO was the one from the common juniper with the MEC of 1.6 mg mL-1. Gas chromatography / mass spectrometry the juniper EO identified monoterpenes (70.54 %) and sesquiterpenes (25.9 %) as dominant component groups. The main monoterpene hydrocarbons were α-pinene, sabinene, and β-pinene. The juniper EO significantly reduced the cell viability of M. intracellulare and M. gordonae at MEC, and of M. avium at 2xMEC. Microscopic analysis confirmed its inhibitory effect by revealing significant morphological changes in the cell membrane and cytoplasm of all three bacteria. The mode of action of the juniper EO on the cell membrane was confirmed by a marked leakage of intracellular material. Juniper EO has a great practical potential as a complementary or alternative water disinfectant in hot water systems such as baths, swimming pools, spa pools, hot tubs, or even foot baths/whirlpools.
Collapse
|
53
|
Belgini DR, Siqueira VM, Oliveira DM, Fonseca SG, Piccin-Santos V, Dias RS, Quartaroli L, Souza RS, Torres APR, Sousa MP, Silva CM, Silva CC, De Paula SO, Oliveira VM. Integrated diversity analysis of the microbial community in a reverse osmosis system from a Brazilian oil refinery. Syst Appl Microbiol 2018; 41:473-486. [DOI: 10.1016/j.syapm.2018.03.007] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 03/09/2018] [Accepted: 03/13/2018] [Indexed: 10/17/2022]
|
54
|
Preventing Postoperative Atypical Mycobacterial Infection. Ophthalmic Plast Reconstr Surg 2018; 35:235-237. [PMID: 30124611 DOI: 10.1097/iop.0000000000001212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To report a recent outbreak of atypical mycobacterial infection following upper eyelid surgery and the results of a prevention protocol that was successfully instituted to dramatically reduce the infection rate. METHODS This is a multicenter retrospective nonrandomized comparative interventional case series. A chart review of 7 patients who developed atypical mycobacterium infection after undergoing blepharoplasty was conducted. Preventative intervention included exchanging ice compresses for reusable gel packs and substituting tap water with bottled or distilled water for facial cleaning during postoperative care. The main outcome measure was disease incidence. RESULTS Of the 368 patients who underwent upper eyelid blepharoplasty and/or blepharoptosis repair from December 2014 to May 2015, 7 people developed cutaneous atypical mycobacterium infection with an incidence of 1.9%. Eighty-six percent of patients received clarithromycin as part of their treatment with average treatment length of 2.8 months. Debridement was performed in 71% of the patients. Biopsy was performed in all patients, and all had histopathology showing granulomatous inflammation. A prevention protocol was developed to reduce potential inoculation in the immediate postoperative period, which successfully reduced the infection rate from 1.9% to 0.06% (p = 0.019). CONCLUSIONS Atypical mycobacterium infection, although rare, should be considered as a possible diagnosis in a blepharoplasty patient with delayed development of nodular lesions. Long-term clarithromycin therapy and debridement have shown good outcomes for these patients; however, the best treatment for any infection is prevention. This study provides the first evidence based approach within the ophthalmic literature for reducing the mycobacterium infection rate in blepharoplasty patients.
Collapse
|
55
|
Ameh EM, Tyrrel S, Harris J, Ignatiou A, Orlova E, Nocker A. The absence or presence of a lytic coliphage affects the response of Escherichia coli to heat, chlorine, or UV exposure. Folia Microbiol (Praha) 2018; 63:599-606. [PMID: 29546616 DOI: 10.1007/s12223-018-0600-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2018] [Accepted: 03/08/2018] [Indexed: 01/21/2023]
Abstract
Disinfection aims at maximal inactivation of target organisms and the sustainable suppression of their regrowth. Whereas many disinfection efforts achieve efficient inactivation when the effect is measured directly after treatment, there are questions about the sustainability of this effect. One aspect is that the treated bacteria might recover and regain the ability to grow. In an environmental context, another question is how amenable surviving bacteria are to predation by omnipresent bacteriophages. Provisional data suggested that bacteria when subjected to sublethal heat stress might develop a phage-resistant phenotype. The result made us wonder about the susceptibility to phage-mediated lysis for bacteria exposed to a gradient of chlorine and UV-LED disinfection strengths. Whereas bacteria exposed to low sublethal chlorine doses still underwent phage-mediated lysis, the critical chlorine Ct of 0.5 mg min/L eliminated this susceptibility and induced phage resistance in the cells that survived treatment. In the case of UV, even the smallest tested dose of 2.8 mJ/cm2 abolished phage lysis leading to direct regrowth. Results suggest that bacteria surviving disinfection might have higher environmental survival chances directly after treatment compared to non-treated cells. A reason could possibly lie in their compromised metabolism that is essential for phage replication.
Collapse
Affiliation(s)
- Ekwu M Ameh
- Cranfield Water Science Institute, School of Water, Environment and Energy, Cranfield University, Cranfield, Bedfordshire, MK43 0AL, UK
| | - Sean Tyrrel
- Cranfield Water Science Institute, School of Water, Environment and Energy, Cranfield University, Cranfield, Bedfordshire, MK43 0AL, UK
| | - Jim Harris
- Cranfield Institute for Resilient Futures, Cranfield University, Cranfield, Bedfordshire, MK43 0AL, UK
| | - Athanasios Ignatiou
- Institute for Structural and Molecular Biology, Department of Biological Sciences, Birkbeck University of London, Malet Street, London, WC1E 7HX, UK
| | - Elena Orlova
- Institute for Structural and Molecular Biology, Department of Biological Sciences, Birkbeck University of London, Malet Street, London, WC1E 7HX, UK
| | - Andreas Nocker
- Cranfield Water Science Institute, School of Water, Environment and Energy, Cranfield University, Cranfield, Bedfordshire, MK43 0AL, UK. .,IWW Water Centre, Moritzstraße 26, 45476, Mülheim an der Ruhr, Germany.
| |
Collapse
|
56
|
A High-Throughput Approach for Identification of Nontuberculous Mycobacteria in Drinking Water Reveals Relationship between Water Age and Mycobacterium avium. mBio 2018; 9:mBio.02354-17. [PMID: 29440575 PMCID: PMC5821076 DOI: 10.1128/mbio.02354-17] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
Nontuberculous mycobacteria (NTM) frequently detected in drinking water (DW) include species associated with human infections, as well as species rarely linked to disease. Methods for improved the recovery of NTM DNA and high-throughput identification of NTM are needed for risk assessment of NTM infection through DW exposure. In this study, different methods of recovering bacterial DNA from DW were compared, revealing that a phenol-chloroform DNA extraction method yielded two to four times as much total DNA and eight times as much NTM DNA as two commercial DNA extraction kits. This method, combined with high-throughput, single-molecule real-time sequencing of NTM rpoB genes, allowed the identification of NTM to the species, subspecies, and (in some cases) strain levels. This approach was applied to DW samples collected from 15 households serviced by a chloraminated distribution system, with homes located in areas representing short (<24 h) and long (>24 h) distribution system residence times. Multivariate statistical analysis revealed that greater water age (i.e., combined distribution system residence time and home plumbing stagnation time) was associated with a greater relative abundance of Mycobacterium avium subsp. avium, one of the most prevalent NTM causing infections in humans. DW from homes closer to the treatment plant (with a shorter water age) contained more diverse NTM species, including Mycobacterium abscessus and Mycobacterium chelonae. Overall, our approach allows NTM identification to the species and subspecies levels and can be used in future studies to assess the risk of waterborne infection by providing insight into the similarity between environmental and infection-associated NTM. An extraction method for improved recovery of DNA from nontuberculous mycobacteria (NTM), combined with single-molecule real-time sequencing (PacBio) of NTM rpoB genes, was used for high-throughput characterization of NTM species and in some cases strains in drinking water (DW). The extraction procedure recovered, on average, eight times as much NTM DNA and three times as much total DNA from DW as two widely used commercial DNA extraction kits. The combined DNA extraction and sequencing approach allowed high-throughput screening of DW samples to identify NTM, revealing that the relative abundance of Mycobacterium avium subsp. avium increased with water age. Furthermore, the two-step barcoding approach developed as part of the PacBio sequencing method makes this procedure highly adaptable, allowing it to be used for other target genes and species.
Collapse
|
57
|
Mocho JP, Martin DJ, Millington ME, Saavedra Torres Y. Environmental Screening of Aeromonas hydrophila, Mycobacterium spp., and Pseudocapillaria tomentosa in Zebrafish Systems. J Vis Exp 2017. [PMID: 29286459 PMCID: PMC5755534 DOI: 10.3791/55306] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Health monitoring systems are developed and used in zebrafish research facilities because pathogens of Danio rerio such as Aeromonas hydrophila, Mycobacterium spp., and Pseudocapillaria tomentosa have the potential to impair animal welfare and research. The fish are typically analyzed post mortem to detect microbes. The use of sentinels is a suggested way to improve the sensitivity of the surveillance and to reduce the number of animals to sample. The setting of a pre-filtration sentinel tank out of a recirculating system is described. The technique is developed to prevent water pollution and to represent the fish population by a careful selection of age, gender, and strains. In order to use the minimum number of animals, techniques to screen the environment are also detailed. Polymerase Chain Reaction (PCR) on surface sump swabs is used to significantly improve the detection of some prevalent and pathogenic mycobacterial species such as Mycobacterium fortuitum, Mycobacterium haemophilum, and Mycobacterium chelonae. Another environmental method consists of processing the sludge at the bottom of a holding tank or sump to look for P. tomentosa eggs. This is a cheap and fast technique that can be applied in quarantine where a breeding device is submerged into the holding tank of imported animals. Finally, PCR is applied to the sludge sample and A. hydrophila is detected at the sump's bottom and surface. Generally, these environmental screening techniques applied to these specific pathogens have led to an increased sensitivity compared to the testing of pre-filtration sentinels.
Collapse
|
58
|
Huang HL, Cheng MH, Lu PL, Shu CC, Wang JY, Wang JT, Chong IW, Lee LN. Epidemiology and Predictors of NTM Pulmonary Infection in Taiwan - a Retrospective, Five-Year Multicenter Study. Sci Rep 2017; 7:16300. [PMID: 29176633 PMCID: PMC5701172 DOI: 10.1038/s41598-017-16559-z] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2017] [Accepted: 11/15/2017] [Indexed: 01/15/2023] Open
Abstract
Multicenter, longitudinal studies on nontuberculous mycobacteria (NTM) pulmonary infection (PI) are lacking. This study provides a 5-year epidemiological overview of NTM-PI in Taiwan and investigated its predictors. The clinical relevance of each respiratory NTM isolate in six hospitals between 2008 and 2014 was determined according to current guidelines. Recurrent episodes were judged by serial bacteriological results. New episodes of NTM-PI and pulmonary colonization (PC) occurring since 2010 were analyzed. Logistic regression analysis was performed to identify the predictors of NTM-PI. Between 2010 and 2014, the incidence rate of NTM-PI was 46.0 episodes per 100,000 hospital-based patient-years. Mycobacterium avium intracellulare complex (MAC) was predominant in Northern Taiwan, whereas MAC and M. abscessus were copredominant in Southern Taiwan. Multiple episodes occurred in 9.5% of NTM-PI patients. No female predominance was observed, except for MAC-PI. Previous pulmonary tuberculosis and chronic obstructive pulmonary disease (COPD) were the most common pulmonary comorbidities and independent risk factors for NTM-PI. Other risk factors included M. kansasii, M. abscessus, and southern Taiwan. Geographical variation of NTM-PI exists in Taiwan. Clinicians should keep a high suspicion on NTM-PI in the risk population. In endemic area of tuberculosis and COPD, there may be no female predominance in NTM-PI.
Collapse
Affiliation(s)
- Hung-Ling Huang
- Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| | - Meng-Hsuan Cheng
- Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan.,Graduate Institute of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Po-Liang Lu
- Department of Laboratory Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan.,Graduate Institute of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Chin-Chung Shu
- Department of Traumatology, National Taiwan University Hospital, Taipei, Taiwan
| | - Jann-Yuan Wang
- Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan.
| | - Jann-Tay Wang
- Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Inn-Wen Chong
- Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan.,Departments of Respiratory Therapy, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan.,Graduate Institute of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Li-Na Lee
- Department of Laboratory Medicine, Fu Jen Catholic University Hospital, New Taipei City, Taiwan
| |
Collapse
|
59
|
Hawkins BT, Sellgren KL, Klem EJD, Piascik JR, Stoner BR. Electrochemical disinfection of repeatedly recycled blackwater in a free-standing, additive-free toilet. WATER AND ENVIRONMENT JOURNAL : THE JOURNAL 2017; 31:545-551. [PMID: 29242713 PMCID: PMC5724497 DOI: 10.1111/wej.12277] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Decentralized, energy-efficient waste water treatment technologies enabling water reuse are needed to sustainably address sanitation needs in water- and energy-scarce environments. Here, we describe the effects of repeated recycling of disinfected blackwater (as flush liquid) on the energy required to achieve full disinfection with an electrochemical process in a prototype toilet system. The recycled liquid rapidly reached a steady state with total solids reliably ranging between 0.50 and 0.65% and conductivity between 20 and 23 mS/cm through many flush cycles over 15 weeks. The increase in accumulated solids was associated with increased energy demand and wide variation in the free chlorine contact time required to achieve complete disinfection. Further studies on the system at steady state revealed that running at higher voltage modestly improves energy efficiency, and established running parameters that reliably achieve disinfection at fixed run times. These results will guide prototype testing in the field.
Collapse
Affiliation(s)
| | | | | | | | - Brian R. Stoner
- RTI InternationalResearch Triangle ParkNCUSA
- Pratt School of EngineeringDuke UniversityDurhamNCUSA
| |
Collapse
|
60
|
Maleki MR, Kafil HS, Harzandi N, Moaddab SR. Identification of nontuberculous mycobacteria isolated from hospital water by sequence analysis of the hsp65 and 16S rRNA genes. JOURNAL OF WATER AND HEALTH 2017; 15:766-774. [PMID: 29040079 DOI: 10.2166/wh.2017.046] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Nontuberculous mycobacteria (NTM) have emerged as an important cause of opportunistic nosocomial infections. NTM has frequently been isolated from hospital water distribution systems. The aim of this study was to survey the risk of NTM infections and determine the prevalence of NTM species in the hospital water distribution systems in Tabriz, Iran. One hundred and twenty samples of water from different sources of Tabriz hospitals were collected. The samples were filtered through 0.45-µm pore size membranes and decontaminated with 0.01% cetylpyridinium chloride. The sediment was inoculated onto Lowenstein-Jensen medium and incubated for 8 weeks. For identification to the species level, partial sequence analysis of the hsp65 and 16S rRNA genes were used. NTM were detected in 76 (63.3%) of 120 samples. Potentially pathogenic mycobacteria and saprophytic mycobacteria were isolated. Mycobacterium gordonae was the only single species that was present in all types of water. The prevalence of NTM in Tabriz hospitals' water compared with many investigations on hospital waters was high. This indicates that the immunocompromised patients and transplant recipients are at risk of contamination which necessitates considering decontamination of water sources to prevent such potential hazards.
Collapse
Affiliation(s)
- Mehdi Roshdi Maleki
- Department of Microbiology, Faculty of Sciences, Karaj Branch, Islamic Azad University, Karaj, Iran
| | - Hossein Samadi Kafil
- Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Naser Harzandi
- Department of Microbiology, Faculty of Sciences, Karaj Branch, Islamic Azad University, Karaj, Iran
| | - Seyyed Reza Moaddab
- Department of Laboratory Sciences, Faculty of Paramedicine, Tabriz University of Medical Sciences, Tabriz, Iran E-mail:
| |
Collapse
|
61
|
Ma X, Bibby K. Free chlorine and monochloramine inactivation kinetics of Aspergillus and Penicillium in drinking water. WATER RESEARCH 2017; 120:265-271. [PMID: 28501787 DOI: 10.1016/j.watres.2017.04.064] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2016] [Revised: 04/17/2017] [Accepted: 04/26/2017] [Indexed: 06/07/2023]
Abstract
Fungi are near-ubiquitous in potable water distribution systems, but the disinfection kinetics of commonly identified fungi are poorly studied. In the present study, laboratory scale experiments were conducted to evaluate the inactivation kinetics of Aspergillus fumigatus, Aspergillus versicolor, and Penicillium purpurogenum by free chlorine and monochloramine. The observed inactivation data were then fit to a delayed Chick-Watson model. Based on the model parameter estimation, the Ct values (integrated product of disinfectant concentration C and contact time t over defined time intervals) for 99.9% inactivation of the tested fungal strains ranged from 48.99 mg min/L to 194.7 mg min/L for free chlorine and from 90.33 mg min/L to 531.3 mg min/L for monochloramine. Fungal isolates from a drinking water system (Aspergillus versicolor and Penicillium purpurogenum) were more disinfection resistant than Aspergillus fumigatus type and clinical isolates. The required 99.9% inactivation Ct values for the tested fungal strains are higher than E. coli, a commonly monitored indicator bacteria, and within a similar range for bacteria commonly identified within water distribution systems, such as Mycobacterium spp. and Legionella spp.
Collapse
Affiliation(s)
- Xiao Ma
- Department of Civil and Environmental Engineering, University of Pittsburgh, Pittsburgh, PA 15261, USA
| | - Kyle Bibby
- Department of Civil and Environmental Engineering, University of Pittsburgh, Pittsburgh, PA 15261, USA; Department of Computational and Systems Biology, University of Pittsburgh Medical School, Pittsburgh, PA 15261, USA.
| |
Collapse
|
62
|
Mishra PS, Narang P, Narang R, Goswami B, Mendiratta DK. Spatio-temporal study of environmental nontuberculous mycobacteria isolated from Wardha district in Central India. Antonie van Leeuwenhoek 2017; 111:73-87. [DOI: 10.1007/s10482-017-0927-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2017] [Accepted: 08/09/2017] [Indexed: 10/19/2022]
|
63
|
Crim MJ, Lawrence C, Livingston RS, Rakitin A, Hurley SJ, Riley LK. Comparison of Antemortem and Environmental Samples for Zebrafish Health Monitoring and Quarantine. JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE : JAALAS 2017; 56:412-424. [PMID: 28724491 PMCID: PMC5517331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Received: 08/05/2016] [Revised: 10/14/2016] [Accepted: 01/12/2017] [Indexed: 06/07/2023]
Abstract
Molecular diagnostic assays offer both exquisite sensitivity and the ability to test a wide variety of sample types. Various types of environmental sample, such as detritus and concentrated water, might provide a useful adjunct to sentinels in routine zebrafish health monitoring. Similarly, antemortem sampling would be advantageous for expediting zebrafish quarantine, without euthanasia of valuable fish. We evaluated the detection of Mycobacterium chelonae, M. fortuitum, M. peregrinum, Pseudocapillaria tomentosa, and Pseudoloma neurophilia in zebrafish, detritus, pooled feces, and filter membranes after filtration of 1000-, 500-, and 150-mL water samples by real-time PCR analysis. Sensitivity varied according to sample type and pathogen, and environmental sampling was significantly more sensitive than zebrafish sampling for detecting Mycobacterium spp. but not for Pseudocapillaria neurophilia or Pseudoloma tomentosa. The results of these experiments provide strong evidence of the utility of multiple sample types for detecting pathogens according to each pathogen's life cycle and ecological niche within zebrafish systems. In a separate experiment, zebrafish subclinically infected with M. chelonae, M. marinum, Pleistophora hyphessobryconis, Pseudocapillaria tomentosa, or Pseudoloma neurophilia were pair-spawned and individually tested with subsets of embryos from each clutch that received no rinse, a fluidizing rinse, or were surface-disinfected with sodium hypochlorite. Frequently, one or both parents were subclinically infected with pathogen(s) that were not detected in any embryo subset. Therefore, negative results from embryo samples may not reflect the health status of the parent zebrafish.
Collapse
Affiliation(s)
- Marcus J Crim
- IDEXX BioResearch, Columbia, Missouri, Department of Veterinary Pathobiology, University of Missouri, Columbia, Missouri;,
| | | | | | | | | | | |
Collapse
|
64
|
Nie XB, Li ZH, Long YN, He PP, Xu C. Chlorine inactivation of Tubifex tubifex in drinking water and the synergistic effect of sequential inactivation with UV irradiation and chlorine. CHEMOSPHERE 2017; 177:7-14. [PMID: 28279903 DOI: 10.1016/j.chemosphere.2017.02.142] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2016] [Revised: 02/26/2017] [Accepted: 02/27/2017] [Indexed: 06/06/2023]
Abstract
The inactivation of Tubifex tubifex is important to prevent contamination of drinking water. Chlorine is a widely-used disinfectant and the key factor in the inactivation of T. tubifex. This study investigated the inactivation kinetics of chlorine on T. tubifex and the synergistic effect of the sequential use of chlorine and UV irradiation. The experimental results indicated that the Ct (concentration × timereaction) concept could be used to evaluate the inactivation kinetics of T. tubifex with chlorine, thus allowing for the use of a simpler Ct approach for the assessment of T. tubifex chlorine inactivation requirements. The inactivation kinetics of T. tubifex by chlorine was found to be well-fitted to a delayed pseudo first-order Chick-Watson expression. Sequential experiments revealed that UV irradiation and chlorine worked synergistically to effectively inactivate T. tubifex as a result of the decreased activation energy, Ea, induced by primary UV irradiation. Furthermore, the inactivation effectiveness of T. tubifex by chlorine was found to be affected by several drinking water quality parameters including pH, turbidity, and chemical oxygen demand with potassium permanganate (CODMn) concentration. High pH exhibited pronounced inactivation effectiveness and the decrease in turbidity and CODMn concentrations contributed to the inactivation of T. tubifex.
Collapse
Affiliation(s)
- Xiao-Bao Nie
- School of Hydraulic Engineering, Changsha University of Science & Technology, Changsha, Hunan, 410114, PR China; Hunan Province Key Laboratory of Water, Sediment Sciences & Flood Hazard Prevention, Changsha, Hunan, 410114, PR China.
| | - Zhi-Hong Li
- School of Hydraulic Engineering, Changsha University of Science & Technology, Changsha, Hunan, 410114, PR China; Hunan Province Key Laboratory of Water, Sediment Sciences & Flood Hazard Prevention, Changsha, Hunan, 410114, PR China
| | - Yuan-Nan Long
- School of Hydraulic Engineering, Changsha University of Science & Technology, Changsha, Hunan, 410114, PR China; Hunan Province Key Laboratory of Water, Sediment Sciences & Flood Hazard Prevention, Changsha, Hunan, 410114, PR China
| | - Pan-Pan He
- School of Hydraulic Engineering, Changsha University of Science & Technology, Changsha, Hunan, 410114, PR China; Hunan Province Key Laboratory of Water, Sediment Sciences & Flood Hazard Prevention, Changsha, Hunan, 410114, PR China
| | - Chao Xu
- School of Hydraulic Engineering, Changsha University of Science & Technology, Changsha, Hunan, 410114, PR China; Hunan Province Key Laboratory of Water, Sediment Sciences & Flood Hazard Prevention, Changsha, Hunan, 410114, PR China
| |
Collapse
|
65
|
Comparison of microbial community shifts in two parallel multi-step drinking water treatment processes. Appl Microbiol Biotechnol 2017; 101:5531-5541. [DOI: 10.1007/s00253-017-8258-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2017] [Revised: 03/15/2017] [Accepted: 03/17/2017] [Indexed: 01/27/2023]
|
66
|
Zhou X, Zhang K, Zhang T, Li C, Mao X. An ignored and potential source of taste and odor (T&O) issues—biofilms in drinking water distribution system (DWDS). Appl Microbiol Biotechnol 2017; 101:3537-3550. [DOI: 10.1007/s00253-017-8223-7] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2017] [Revised: 02/26/2017] [Accepted: 03/04/2017] [Indexed: 01/10/2023]
|
67
|
Van Nevel S, Buysschaert B, De Roy K, De Gusseme B, Clement L, Boon N. Flow cytometry for immediate follow-up of drinking water networks after maintenance. WATER RESEARCH 2017; 111:66-73. [PMID: 28043001 DOI: 10.1016/j.watres.2016.12.040] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2016] [Revised: 12/22/2016] [Accepted: 12/24/2016] [Indexed: 05/16/2023]
Abstract
Drinking water networks need maintenance every once in a while, either planned interventions or emergency repairs. When this involves opening of the water pipes, precautionary measures need to be taken to avoid contamination of the drinking water at all time. Drinking water suppliers routinely apply plating for faecal indicator organisms as quality control in such a situation. However, this takes at least 21 h of waiting time, which can be crucial when dealing with major supply pipes. A combination of flow cytometric (FCM) bacterial cell counts with FCM fingerprinting techniques is proposed in this study as a fast and sensitive additional technique. In three full scale situations, major supply pipes with 400-1050 mm diameter were emptied for maintenance, shock-chlorinated and flushed with large amounts of clean drinking water before taking back in operation. FCM measurements of the discharged flushing water revealed fast lowering and stabilizing bacterial concentrations once flushing is initiated. Immediate comparison with clean reference drinking water used for flushing was done, and the moment when both waters had similar bacterial concentrations was considered as the endpoint of the necessary flushing works. This was usually after 2-4 h of flushing. FCM fingerprinting, based on both bacteria and FCM background, was used as additional method to verify how similar flushing and reference samples were and yielded similar results. The FCM approved samples were several hours later approved as well by the drinking water supplier after plating and incubation for total Coliforms and Enterococci. These were used as decisive control to set the pipes back in operation. FCM proved to be a more conservative test than plating, yet it yielded immediate results. Application of these FCM methods can therefore avoid long unnecessary waiting times and large drinking water losses.
Collapse
Affiliation(s)
- Sam Van Nevel
- Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, B-9000 Gent, Belgium
| | - Benjamin Buysschaert
- Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, B-9000 Gent, Belgium
| | - Karen De Roy
- Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, B-9000 Gent, Belgium
| | - Bart De Gusseme
- Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, B-9000 Gent, Belgium; Engineering TMVW (FARYS), Stropstraat 1, B-9000 Gent, Belgium
| | - Lieven Clement
- Department of Applied Mathematics, Computer Science and Statistics, Ghent University, Krijgslaan 281 S9, B-9000 Gent, Belgium
| | - Nico Boon
- Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, B-9000 Gent, Belgium.
| |
Collapse
|
68
|
Amha YM, Anwar MZ, Kumaraswamy R, Henschel A, Ahmad F. Mycobacteria in Municipal Wastewater Treatment and Reuse: Microbial Diversity for Screening the Occurrence of Clinically and Environmentally Relevant Species in Arid Regions. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2017; 51:3048-3056. [PMID: 28139909 DOI: 10.1021/acs.est.6b05580] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
With accumulating evidence of pulmonary infection via aerosolized nontuberculous mycobacteria (NTM), it is important to characterize their persistence in wastewater treatment, especially in arid regions where treated municipal wastewater is extensively reused. To achieve this goal, microbial diversity of the genus Mycobacterium was screened for clinically and environmentally relevant species using pyrosequencing. Analysis of the postdisinfected treated wastewater showed the presence of clinically relevant slow growers like M. kansasii, M. szulgai, M. gordonae, and M. asiaticum; however, in these samples, rapid growers like M. mageritense occurred at much higher relative abundance. M. asiaticum and M. mageritense have been isolated in pulmonary samples from NTM-infected patients in the region. Diversity analysis along the treatment train found environmentally relevant organisms like M. poriferae and M. insubricum to increase in relative abundance across the chlorine disinfection step. A comparison to qPCR results across the chlorine disinfection step saw no significant change in slow grower counts at CT disinfection values ≤90 mg·min/L; only an increase to 180 mg·min/L in late May brought slow growers to below detection levels. The study confirms the occurrence of clinically and environmentally relevant mycobacteria in treated municipal wastewater, suggesting the need for vigilant monitoring of treated wastewater quality and disinfection effectiveness prior to reuse.
Collapse
Affiliation(s)
- Yamrot M Amha
- Institute Center for Water and Environment (iWATER) and ‡Institute Center for Smart and Sustainable Systems (iSmart), Masdar Institute of Science and Technology , P.O. Box 54224, Abu Dhabi, UAE
| | - M Zohaib Anwar
- Institute Center for Water and Environment (iWATER) and ‡Institute Center for Smart and Sustainable Systems (iSmart), Masdar Institute of Science and Technology , P.O. Box 54224, Abu Dhabi, UAE
| | - Rajkumari Kumaraswamy
- Institute Center for Water and Environment (iWATER) and ‡Institute Center for Smart and Sustainable Systems (iSmart), Masdar Institute of Science and Technology , P.O. Box 54224, Abu Dhabi, UAE
| | - Andreas Henschel
- Institute Center for Water and Environment (iWATER) and ‡Institute Center for Smart and Sustainable Systems (iSmart), Masdar Institute of Science and Technology , P.O. Box 54224, Abu Dhabi, UAE
| | - Farrukh Ahmad
- Institute Center for Water and Environment (iWATER) and ‡Institute Center for Smart and Sustainable Systems (iSmart), Masdar Institute of Science and Technology , P.O. Box 54224, Abu Dhabi, UAE
| |
Collapse
|
69
|
Nishiuchi Y, Iwamoto T, Maruyama F. Infection Sources of a Common Non-tuberculous Mycobacterial Pathogen, Mycobacterium avium Complex. Front Med (Lausanne) 2017; 4:27. [PMID: 28326308 PMCID: PMC5339636 DOI: 10.3389/fmed.2017.00027] [Citation(s) in RCA: 114] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2017] [Accepted: 02/22/2017] [Indexed: 01/08/2023] Open
Abstract
Numerous studies have revealed a continuous increase in the worldwide incidence and prevalence of non-tuberculous mycobacteria (NTM) diseases, especially pulmonary Mycobacterium avium complex (MAC) diseases. Although it is not clear why NTM diseases have been increasing, one possibility is an increase of mycobacterial infection sources in the environment. Thus, in this review, we focused on the infection sources of pathogenic NTM, especially MAC. The environmental niches for MAC include water, soil, and dust. The formation of aerosols containing NTM arising from shower water, soil, and pool water implies that these niches can be infection sources. Furthermore, genotyping has shown that clinical isolates are identical to environmental ones from household tap water, bathrooms, potting soil, and garden soil. Therefore, to prevent and treat MAC diseases, it is essential to identify the infection sources for these organisms, because patients with these diseases often suffer from reinfections and recurrent infections with them. In the environmental sources, MAC and other NTM organisms can form biofilms, survive within amoebae, and exist in a free-living state. Mycobacterial communities are also likely to occur in these infection sources in households. Water distribution systems are a transmission route from natural water reservoirs to household tap water. Other infection sources include areas with frequent human contact, such as soil and bathrooms, indicating that individuals may carry NTM organisms that concomitantly attach to their household belongings. To explore the mechanisms associated with the global spread of infection and MAC transmission routes, an epidemiological population-wide genotyping survey would be very useful. A good example of the power of genotyping comes from M. avium subsp. hominissuis, where close genetic relatedness was found between isolates of it from European patients and pigs in Japan and Europe, implying global transmission of this bacterium. It is anticipated that whole genome sequencing technologies will improve NTM surveys so that the mechanisms for the global spread of MAC disease will become clearer in the near future. Better understanding of the niches exploited by MAC and its ecology is essential for preventing MAC infections and developing new methods for its effective treatment and elimination.
Collapse
Affiliation(s)
- Yukiko Nishiuchi
- Toneyama Institute for Tuberculosis Research, Osaka City University Medical School , Toyonaka , Japan
| | - Tomotada Iwamoto
- Department of Infectious Diseases, Kobe Institute of Health , Kobe , Japan
| | - Fumito Maruyama
- Section of Microbiology, Graduate School of Medicine and Faculty of Medicine, Kyoto University , Kyoto , Japan
| |
Collapse
|
70
|
Wu CH, Thong HY, Huang CC, Chen PH. Report of two cases of cutaneous Mycobacterium abscessus infection complicating professional decorative tattoo. DERMATOL SIN 2017. [DOI: 10.1016/j.dsi.2016.06.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
|
71
|
Dagher D, Ungar K, Robison R, Dagher F. The wide spectrum high biocidal potency of Bioxy formulation when dissolved in water at different concentrations. PLoS One 2017; 12:e0172224. [PMID: 28207828 PMCID: PMC5313143 DOI: 10.1371/journal.pone.0172224] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2016] [Accepted: 02/01/2017] [Indexed: 11/18/2022] Open
Abstract
Traditional surface disinfectants that have long been applied in medicine, animal husbandry, manufacturing and institutions are inconvenient at best and dangerous at worst. Moreover, some of these substances have adverse environmental impacts: for example, quaternary ammonium compounds ("quats") are reproductive toxicants in both fish and mammals. Halogens are corrosive both to metals and living tissues, are highly reactive, can be readily neutralized by metals, and react with organic matter to form toxic, persistent by-products such as dioxins and furans. Aldehydes may be carcinogenic to both human and animals upon repeated exposures, are corrosive, cross-link living tissues and many synthetic materials, and may lose efficacy when pathogens enzymatically adapt to them. Alcohols are flammable and volatile and can be enzymatically degraded by certain bacterial pathogens. Quats are highly irritating to mucous membranes and over time can induce pathogen resistance, especially if they are not alternated with functionally different disinfectants. In contrast, peracetic acid (PAA), a potent oxidizer, liberates hydrogen peroxide (itself a disinfectant), biodegrades to carbon dioxide, water and oxygen, and is at least as efficacious as contact biocides e.g., halogens and aldehydes. Nevertheless, the standard form of liquid PAA is highly corrosive, is neutralized by metals and organic matter, gives off noxious odours and must be stored in vented containers. For the reasons stated above, Bioxy formulations were developed, a series of powder forms of PAA, which are odourless, stable in storage and safe to transport and handle. They generate up to 10% PAA in situ when dissolved in water. A 0.2% aqueous solution of Bioxy (equivalent to 200 ppm PAA) effected a 6.76 log reduction in Methicillin-resistant Staphylococcus aureus (MRSA) within 2 minutes after application. A 5% aqueous solution of Bioxy achieved a 3.93 log reduction in the bovine tuberculosis bacillus Mycobacterium bovis, within 10 minutes after contact. A 1% solution of Bioxy reduced vancomycin-resistant enterococci (VRE) and Pseudomonas aeruginosa by 6.31 and 7.18 logs, respectively, within 3 minutes after application. A 0.5% solution of Bioxy inactivated porcine epidemic diarrhea virus (PEDV) within 15 minutes of contact, and a 5% solution of Bioxy realized a 5.36 log reduction in the spores of Clostridium difficile within 10 minutes of application. In summary, Bioxy is safe and easy to transport and store, poses negligible human, animal and environmental health risks, shows high levels of pathogen control efficacy and does not induce microbial resistance. Further investigations are recommended to explore its use as an industrial biocide.
Collapse
Affiliation(s)
- Dori Dagher
- Bioxy AFD Inc. and Atomes F.D. Inc., Ville Saint-Laurent, Quebec, Canada
| | - Ken Ungar
- Bioxy AFD Inc. and Atomes F.D. Inc., Ville Saint-Laurent, Quebec, Canada
| | - Richard Robison
- Brigham Young University, Provo, Utah, United States of America
| | - Fadi Dagher
- Bioxy AFD Inc. and Atomes F.D. Inc., Ville Saint-Laurent, Quebec, Canada
- * E-mail:
| |
Collapse
|
72
|
Nunes-Costa D, Maranha A, Costa M, Alarico S, Empadinhas N. Glucosylglycerate metabolism, bioversatility and mycobacterial survival. Glycobiology 2016; 27:213-227. [DOI: 10.1093/glycob/cww132] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Accepted: 12/14/2016] [Indexed: 12/17/2022] Open
|
73
|
Species diversity and molecular characterization of nontuberculous mycobacteria in hospital water system of a developing country, Iran. Microb Pathog 2016; 100:62-69. [PMID: 27616445 DOI: 10.1016/j.micpath.2016.09.004] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2016] [Accepted: 09/06/2016] [Indexed: 11/24/2022]
Abstract
BACKGROUND Hospital environment is of crucial importance in cross-transmission of opportunistic pathogens to the patients. Nontuberculous mycobacteria have the remarkable capability to withstand the adverse condition of hospital environments and pose a potential threat to the health of patients. The current study aimed to assess the frequency and diversity of mycobacteria in hospital water of a developing country using a combination of conventional and molecular methods. METHODS A total of 148 hospital water samples collected from 38 hospitals were analyzed for the presence of mycobacteria using standard protocols for isolation and characterization of the isolates. The conventional tests were used for preliminary identification and Runyon's classification, the PCR amplification of hsp65 gene and sequence analysis of 16S rRNA were applied for the genus and species identification. RESULTS A total of 71 [48%] isolates including 30 rapidly growing and 41 slowly growing mycobacteria were recovered. The three most prevalent species were M. lentiflavum, 28.2%, M. paragordonae, 21.1%, and M. fredriksbergense, 9.8%, followed by M. simiae and M. novocastrense, 7%, M. canariasense and M. cookii like, 5.6%, M. setense, 4.2%, M. fortuitum and M. gordonae, 2.8%, and the single isolates of M. austroafricanum, M. massiliense, M. obuense, and M. phocaicum like. CONCLUSION The results of our study show that the hospital water resources, drinking or non-drinking can be the reservoir of a diverse range of mycobacteria. This reaffirms the fact that these organisms due to intrinsic resistance to common antiseptic and disinfectant solutions persist in hospitals and create a threat to the patient's health and in particular to those that suffer from weakness of immunity.
Collapse
|
74
|
Khaledi A, Bahador A, Esmaeili D, Tafazoli A, Ghazvini K, Mansury D. Prevalence of nontuberculous mycobacteria isolated from environmental samples in Iran: A meta-analysis. JOURNAL OF RESEARCH IN MEDICAL SCIENCES 2016; 21:58. [PMID: 27904603 PMCID: PMC5121994 DOI: 10.4103/1735-1995.187306] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/10/2016] [Revised: 05/14/2016] [Accepted: 07/02/2016] [Indexed: 11/04/2022]
Abstract
BACKGROUND While the most nontuberculous mycobacteria (NTMs) species are considered as opportunistic pathogens, some of them are related to several human infections. It is believed that environment is the main source for these infections. Distribution and scattering pattern of NTMs has not been well studied in Iran and a few studies about this subject have been done, so the aim of this study was to determine prevalence of NTMs in environmental samples from Iran. MATERIALS AND METHODS Data about prevalence of NTMs in environmental samples from Iran were obtained by searching databases. The studies presenting cross-sectional or cohort and the papers with sample size ≥30 were included. Then, the meta-analysis was performed using Comprehensive Meta-Analysis software and Cochran's Q and I2 tests. The strategy search was based PRISMA protocol is available online (PRISMA, http://www.prisma-statement.org). RESULTS The results of this meta-analysis showed that overall combined prevalence of NTMs in environmental samples from Iran was 38.3%. The frequency of NTM was higher in the north of Iran (73.2%). The most prevalent rapid-growing mycobacterium was Mycobacterium fortuitum (19.8%), and the most dominant slow-growing mycobacterium was Mycobacterium flavescens (16.8%). CONCLUSION In regard to increasing incidence of disease in immunocompromised patients and existence of different types of mycobacteria species in environmental samples, efforts should be focused on measures that will specifically remove NTMs from habitats where susceptible individuals are exposed.
Collapse
Affiliation(s)
- Azad Khaledi
- Department of Microbiology and Virology, Antimicrobial Resistance Research Center, Avicenna Research Institute, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Abbas Bahador
- Department of Microbiology, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Davood Esmaeili
- Department of Microbiology, Applied Microbiology Research Center, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Alireza Tafazoli
- Medical Genetics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Kiarash Ghazvini
- Department of Microbiology and Virology, Antimicrobial Resistance Research Center, Avicenna Research Institute, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Davood Mansury
- Department of Microbiology and Virology, Antimicrobial Resistance Research Center, Avicenna Research Institute, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| |
Collapse
|
75
|
Bédard E, Prévost M, Déziel E. Pseudomonas aeruginosa in premise plumbing of large buildings. Microbiologyopen 2016; 5:937-956. [PMID: 27353357 PMCID: PMC5221438 DOI: 10.1002/mbo3.391] [Citation(s) in RCA: 98] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2016] [Revised: 06/01/2016] [Accepted: 06/06/2016] [Indexed: 12/27/2022] Open
Abstract
Pseudomonas aeruginosa is an opportunistic bacterial pathogen that is widely occurring in the environment and is recognized for its capacity to form or join biofilms. The present review consolidates current knowledge on P. aeruginosa ecology and its implication in healthcare facilities premise plumbing. The adaptability of P. aeruginosa and its capacity to integrate the biofilm from the faucet and the drain highlight the role premise plumbing devices can play in promoting growth and persistence. A meta‐analysis of P. aeruginosa prevalence in faucets (manual and electronic) and drains reveals the large variation in device positivity reported and suggest the high variability in the sampling approach and context as the main reason for this variation. The effects of the operating conditions that prevail within water distribution systems (disinfection, temperature, and hydraulic regime) on the persistence of P. aeruginosa are summarized. As a result from the review, recommendations for proactive control measures of water contamination by P. aeruginosa are presented. A better understanding of the ecology of P. aeruginosa and key influencing factors in premise plumbing are essential to identify culprit areas and implement effective control measures.
Collapse
Affiliation(s)
- Emilie Bédard
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC, Canada.,INRS-Institut Armand-Frappier, Laval, QC, Canada
| | - Michèle Prévost
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC, Canada
| | - Eric Déziel
- INRS-Institut Armand-Frappier, Laval, QC, Canada
| |
Collapse
|
76
|
Riello FN, Brígido RTS, Araújo S, Moreira TA, Goulart LR, Goulart IMB. Diagnosis of mycobacterial infections based on acid-fast bacilli test and bacterial growth time and implications on treatment and disease outcome. BMC Infect Dis 2016; 16:142. [PMID: 27039183 PMCID: PMC4818481 DOI: 10.1186/s12879-016-1474-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2015] [Accepted: 03/17/2016] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The establishment of therapeutic regimens for mycobacteriosis depends on the accurate identification of Mycobacterium species, and misdiagnosis can result in inappropriate treatment and increased mortality of patients. Differential diagnosis among Mycobacterium species has been made by conventional phenotypic and biochemical tests after a long culture period. Specialized molecular diagnostics of mycobacteria allows rapid detection and species identification; however, such tests are not available in public health programs. Our aim was to demonstrate the clinical implications of erroneous diagnosis by performing molecular genotyping of mycobacterial infections in patients that were diagnosed based on symptoms, culture and bacilloscopy. METHODS Culture samples of mycobacterial infections from 55 patients clinically diagnosed as tuberculosis in 2013 and 2014, based on conventional methods, were identified by PCR -RFLP and results are discussed. RESULTS We have confirmed 35 (63.6%) positive samples as M. tuberculosis, but 18 (32.7%) were identified as non-tuberculous mycobacteria (M. avium type 1, M. avium type 2, M. kansasii type 1 type 1, M. mucogenicum, M. chelonae, M. terrae type 3, and 1 unknown RFLP pattern) and two were negative. Regarding clinical diagnosis, 61.8% (34/55) was classified as pulmonary tuberculosis. It is important to emphasize that 36.4% (20/55) of samples were misdiagnosed by conventional methods, and 11 (61.1%) of the HIV positive patients (18/55) were NTM-coinfected. CONCLUSION The identification of species in mycobacterial infections is essential for correct diagnosis and choice of treatment regimen, and misdiagnosis by conventional tools can lead to chronic disease, increased resistance and death.
Collapse
Affiliation(s)
- Fabiane N. Riello
- />National Reference Center for Sanitary Dermatology and Leprosy (CREDESH) Clinical Hospital Federal University of Uberlândia, Uberlândia, Minas Gerais Brazil
| | - Rebecca T. S. Brígido
- />National Reference Center for Sanitary Dermatology and Leprosy (CREDESH) Clinical Hospital Federal University of Uberlândia, Uberlândia, Minas Gerais Brazil
| | - Sergio Araújo
- />National Reference Center for Sanitary Dermatology and Leprosy (CREDESH) Clinical Hospital Federal University of Uberlândia, Uberlândia, Minas Gerais Brazil
| | - Tomaz A. Moreira
- />Laboratory of Clinical Analysis, Clinics’ Hospital of the Federal University of Uberlândia, Uberlândia, Minas Gerais Brazil
| | - Luiz Ricardo Goulart
- />Federal University of Uberlandia, Institute of Genetics and Biochemistry, Laboratory of Nanobiotechnology, Campus Umuarama, Block 2E, Room 248, CEP 38400-902 Uberlandia, Minas Gerais Brazil
| | - Isabela M. B. Goulart
- />National Reference Center for Sanitary Dermatology and Leprosy (CREDESH) Clinical Hospital Federal University of Uberlândia, Uberlândia, Minas Gerais Brazil
| |
Collapse
|
77
|
Bharat V, Hittinahalli V, Mishra M, Pradhan S. Pacemaker pocket infection due to environmental mycobacteria: Successful management of an outbreak and steps for prevention in future. Indian Heart J 2016; 68:63-7. [PMID: 26896269 PMCID: PMC4759492 DOI: 10.1016/j.ihj.2015.06.023] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2014] [Revised: 06/02/2015] [Accepted: 06/16/2015] [Indexed: 11/05/2022] Open
Abstract
Background An outbreak of surgical site infection (SSI) due to environmental mycobacteria (EMB) occurred in a hospital in Eastern India. Method A quality improvement project (QIP) was undertaken to analyze the causes and prevent further outbreak. Step (1) Proof of the need: Four patients who had undergone pacemaker implantation consecutively during a 10-day period developed SSI. Step (2) Diagnostic journey: Since all patients developed SSI within 2 months of implantation, a common source of infection was likely. Atypical mycobacteria (AMB) were grown from surgical sites as well as from the surface of operation table, image intensifier, and lead aprons. It was a rapid growing variety that lacked pigment, a characteristic of EMB with pathogenic potential. The EMB was finally traced to its source, the overhead water tank. Step (3) Remedial journey: By thorough cleaning of the water tank and enriching its chlorine content, the EMB was eliminated from its source. Step (4) Holding the gains: Protocol for cleaning the water tank once in 3 months was made. A checklist was prepared to ensure compliance to asepsis protocol in the operation theater. In the ensuing 5 years, the infection did not recur. Result The bacteria that caused SSI were identified as EMB that grew in the water tank and contaminated the operation room. It could be eliminated by appropriate measures. Interpretation Water is a potential reservoir for EMB. Use of the term ‘environmental mycobacteria’ instead of ‘atypical mycobacteria’ will generate awareness about contamination as the cause of SSI.
Collapse
Affiliation(s)
- Vijaya Bharat
- Head of the Department of Cardiology and in-charge ICU, Tata Main Hospital, Jamshedpur, India.
| | | | | | | |
Collapse
|
78
|
Nunes-Costa D, Alarico S, Dalcolmo MP, Correia-Neves M, Empadinhas N. The looming tide of nontuberculous mycobacterial infections in Portugal and Brazil. Tuberculosis (Edinb) 2015; 96:107-19. [PMID: 26560840 DOI: 10.1016/j.tube.2015.09.006] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2015] [Revised: 08/27/2015] [Accepted: 09/16/2015] [Indexed: 01/15/2023]
Abstract
Nontuberculous mycobacteria (NTM) are widely disseminated in the environment and an emerging cause of infectious diseases worldwide. Their remarkable natural resistance to disinfectants and antibiotics and an ability to survive under low-nutrient conditions allows NTM to colonize and persist in man-made environments such as household and hospital water distribution systems. This overlap between human and NTM environments afforded new opportunities for human exposure, and for expression of their often neglected and underestimated pathogenic potential. Some risk factors predisposing to NTM disease have been identified and are mainly associated with immune fragilities of the human host. However, infections in apparently immunocompetent persons are also increasingly reported. The purpose of this review is to bring attention to this emerging health problem in Portugal and Brazil and to emphasize the urgent need for increased surveillance and more comprehensive epidemiological data in both countries, where such information is scarce and seriously thwarts the adoption of proper preventive strategies and therapeutic options.
Collapse
Affiliation(s)
- Daniela Nunes-Costa
- CNC - Center for Neuroscience and Cell Biology, University of Coimbra, Coimbra, Portugal
| | - Susana Alarico
- CNC - Center for Neuroscience and Cell Biology, University of Coimbra, Coimbra, Portugal
| | | | - Margarida Correia-Neves
- ICVS - Health and Life Sciences Research Institute, University of Minho, Braga, Portugal; ICVS/3B's, PT Government Associate Laboratory, Braga/Guimarães, Portugal
| | - Nuno Empadinhas
- CNC - Center for Neuroscience and Cell Biology, University of Coimbra, Coimbra, Portugal; IIIUC - Institute for Interdisciplinary Research, University of Coimbra, Coimbra, Portugal.
| |
Collapse
|
79
|
Ji P, Parks J, Edwards MA, Pruden A. Impact of Water Chemistry, Pipe Material and Stagnation on the Building Plumbing Microbiome. PLoS One 2015; 10:e0141087. [PMID: 26495985 PMCID: PMC4619671 DOI: 10.1371/journal.pone.0141087] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2015] [Accepted: 10/03/2015] [Indexed: 02/07/2023] Open
Abstract
A unique microbiome establishes in the portion of the potable water distribution system within homes and other buildings (i.e., building plumbing). To examine its composition and the factors that shape it, standardized cold water plumbing rigs were deployed at the treatment plant and in the distribution system of five water utilities across the U.S. Three pipe materials (copper with lead solder, CPVC with brass fittings or copper/lead combined pipe) were compared, with 8 hour flush cycles of 10 minutes to simulate typical daily use patterns. High throughput Illumina sequencing of 16S rRNA gene amplicons was employed to profile and compare the resident bulk water bacteria and archaea. The utility, location of the pipe rig, pipe material and stagnation all had a significant influence on the plumbing microbiome composition, but the utility source water and treatment practices were dominant factors. Examination of 21 water chemistry parameters suggested that the total chlorine concentration, pH, P, SO42- and Mg were associated with the most of the variation in bulk water microbiome composition. Disinfectant type exerted a notably low-magnitude impact on microbiome composition. At two utilities using the same source water, slight differences in treatment approaches were associated with differences in rare taxa in samples. For genera containing opportunistic pathogens, Utility C samples (highest pH of 9–10) had the highest frequency of detection for Legionella spp. and lowest relative abundance of Mycobacterium spp. Data were examined across utilities to identify a true universal core, special core, and peripheral organisms to deepen insight into the physical and chemical factors that shape the building plumbing microbiome.
Collapse
Affiliation(s)
- Pan Ji
- Via Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia, United States of America
| | - Jeffrey Parks
- Via Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia, United States of America
| | - Marc A. Edwards
- Via Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia, United States of America
| | - Amy Pruden
- Via Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia, United States of America
- * E-mail:
| |
Collapse
|
80
|
Lee ES, Lee MH, Kim BS. Evaluation of propidium monoazide-quantitative PCR to detect viable Mycobacterium fortuitum after chlorine, ozone, and ultraviolet disinfection. Int J Food Microbiol 2015; 210:143-8. [DOI: 10.1016/j.ijfoodmicro.2015.06.019] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2014] [Revised: 06/16/2015] [Accepted: 06/22/2015] [Indexed: 10/23/2022]
|
81
|
Costa D, Mercier A, Gravouil K, Lesobre J, Delafont V, Bousseau A, Verdon J, Imbert C. Pyrosequencing analysis of bacterial diversity in dental unit waterlines. WATER RESEARCH 2015; 81:223-231. [PMID: 26072020 DOI: 10.1016/j.watres.2015.05.065] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2015] [Revised: 05/22/2015] [Accepted: 05/31/2015] [Indexed: 06/04/2023]
Abstract
Some infections cases due to exposure to output water from dental unit waterlines (DUWL) have been reported in the literature. However, this type of healthcare-associated risk has remained unclear and up until now the overall bacterial composition of DUWL has been poorly documented. In this study, 454 high-throughput pyrosequencing was used to investigate the bacterial community in seven dental offices (N = 7) and to identify potential bacterial pathogenic sequences. Dental unit waters (DUW) were collected from the tap water supplying units (Incoming Water; IW) to the output exposure point of the turbine handpiece (Output water; OW) following a stagnation period (OWS), and immediately after the last patient of the sampling day (OWA). A high bacterial diversity was revealed in DUW with 394 operational taxonomic units detected at the genus level. In addition to the inter-unit variability observed, results showed increased total bacterial cell concentration and shifts in bacterial community composition and abundance at the genus level, mainly within the Gamma- and Alpha-Proteobacteria class, as water circulated in the dental unit (DU). Results showed that 96.7%, 96.8% and 97.4% of the total sequences from IW, OWS and OWA respectively were common to the 3 defined water groups, thereby highlighting a common core microbiome. Results also suggested that stagnation and DU maintenance practices were critical to composition of the bacterial community. The presence of potentially pathogenic genera was detected, including Pseudomonas and Legionella spp. Emerging and opportunistic pathogenic genera such as Mycobacterium, Propionibacterium and Stenotrophomonas were likewise recovered in DUW. For the first time, an exhaustive evaluation of the bacterial communities present in DUW was performed taking into account the circulation of water within the DU. This study highlights an ignored diversity of the DUWL bacterial community. Our findings also contribute to a better appreciation of the potential infectious risk associated with dental care and suggest the importance of better managing microbial quality in DUW.
Collapse
Affiliation(s)
- Damien Costa
- Equipe Microbiologie de l'Eau, Ecologie et Biologie des Interactions, Centre National de la Recherche Scientifique UMR 7267, Université de Poitiers, Poitiers, France; Bâtiment Urgences et Biologie Médicale (UBM), CHU de Poitiers, Poitiers, France.
| | - Anne Mercier
- Equipe Microbiologie de l'Eau, Ecologie et Biologie des Interactions, Centre National de la Recherche Scientifique UMR 7267, Université de Poitiers, Poitiers, France
| | - Kevin Gravouil
- Laboratoire coopératif Thanaplast(SP)-Carbios Bioplastics, Ecologie et Biologie des Interactions, Centre National de la Recherche Scientifique UMR 7267, Université de Poitiers, Poitiers, France
| | - Jérôme Lesobre
- Université Blaise Pascal, UMR CNRS 6023, Laboratoire Microorganismes: Génome et Environnement, 24 avenue des Landais, Aubière, France
| | - Vincent Delafont
- Equipe Microbiologie de l'Eau, Ecologie et Biologie des Interactions, Centre National de la Recherche Scientifique UMR 7267, Université de Poitiers, Poitiers, France
| | - Anne Bousseau
- Bâtiment Urgences et Biologie Médicale (UBM), CHU de Poitiers, Poitiers, France
| | - Julien Verdon
- Equipe Microbiologie de l'Eau, Ecologie et Biologie des Interactions, Centre National de la Recherche Scientifique UMR 7267, Université de Poitiers, Poitiers, France
| | - Christine Imbert
- Equipe Microbiologie de l'Eau, Ecologie et Biologie des Interactions, Centre National de la Recherche Scientifique UMR 7267, Université de Poitiers, Poitiers, France; Bâtiment Urgences et Biologie Médicale (UBM), CHU de Poitiers, Poitiers, France
| |
Collapse
|
82
|
Gomez-Smith CK, LaPara TM, Hozalski RM. Sulfate Reducing Bacteria and Mycobacteria Dominate the Biofilm Communities in a Chloraminated Drinking Water Distribution System. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2015; 49:8432-8440. [PMID: 26098899 DOI: 10.1021/acs.est.5b00555] [Citation(s) in RCA: 66] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The quantity and composition of bacterial biofilms growing on 10 water mains from a full-scale chloraminated water distribution system were analyzed using real-time PCR targeting the 16S rRNA gene and next-generation, high-throughput Illumina sequencing. Water mains with corrosion tubercles supported the greatest amount of bacterial biomass (n = 25; geometric mean = 2.5 × 10(7) copies cm(-2)), which was significantly higher (P = 0.04) than cement-lined cast-iron mains (n = 6; geometric mean = 2.0 × 10(6) copies cm(-2)). Despite spatial variation of community composition and bacterial abundance in water main biofilms, the communities on the interior main surfaces were surprisingly similar, containing a core group of operational taxonomic units (OTUs) assigned to only 17 different genera. Bacteria from the genus Mycobacterium dominated all communities at the main wall-bulk water interface (25-78% of the community), regardless of main age, estimated water age, main material, and the presence of corrosion products. Further sequencing of the mycobacterial heat shock protein gene (hsp65) provided species-level taxonomic resolution of mycobacteria. The two dominant Mycobacteria present, M. frederiksbergense (arithmetic mean = 85.7% of hsp65 sequences) and M. aurum (arithmetic mean = 6.5% of hsp65 sequences), are generally considered to be nonpathogenic. Two opportunistic pathogens, however, were detected at low numbers: M. hemophilum (arithmetic mean = 1.5% of hsp65 sequences) and M. abscessus (arithmetic mean = 0.006% of hsp65 sequences). Sulfate-reducing bacteria from the genus Desulfovibrio, which have been implicated in microbially influenced corrosion, dominated all communities located underneath corrosion tubercules (arithmetic mean = 67.5% of the community). This research provides novel insights into the quantity and composition of biofilms in full-scale drinking water distribution systems, which is critical for assessing the risks to public health and to the water supply infrastructure.
Collapse
Affiliation(s)
- C Kimloi Gomez-Smith
- †Department of Civil, Environmental, and Geo- Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
- ‡Water Resources Sciences Graduate Program, University of Minnesota, St. Paul, Minnesota 55108, United States
| | - Timothy M LaPara
- †Department of Civil, Environmental, and Geo- Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
- §BioTechnology Institute, University of Minnesota, St. Paul, Minnesota 55108, United States
| | - Raymond M Hozalski
- †Department of Civil, Environmental, and Geo- Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
- §BioTechnology Institute, University of Minnesota, St. Paul, Minnesota 55108, United States
| |
Collapse
|
83
|
Zlojtro M, Jankovic M, Samarzija M, Zmak L, Jankovic VK, Obrovac M, Zlojtro I, Jakopovic M. Nosocomial pseudo-outbreak of Mycobacterium gordonae associated with a hospital's water supply contamination: a case series of 135 patients. JOURNAL OF WATER AND HEALTH 2015; 13:125-130. [PMID: 25719472 DOI: 10.2166/wh.2014.061] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Nontuberculous mycobacteria (NTM) are opportunistic pathogens found in natural and human-engineered waters. In 2009, a relative increase in the isolation of Mycobacterium gordonae from pulmonary samples originating from General Hospital Zabok was noted by the National Mycobacteria Reference Laboratory. An epidemiological survey revealed a contamination of the cold tap water with M. gordonae and guidelines regarding sputum sample taking were issued. In addition, all incident cases of respiratory infection due to NTM reported from 2007 to 2012 at General Hospital Zabok were included in a retrospective review. Out of 150 individual NTM isolates, M. gordonae was the most frequently isolated species (n = 135; 90%) and none of the cases met the criteria of the American Thoracic Society for pulmonary NTM disease. While concomitant Mycobacterium tuberculosis infection was confirmed in only 6 (4%) patients, anti-tuberculosis treatment was initiated for a significant portion of patients (n = 64; 42.6%) and unnecessary contact tracing was performed. This study points out the need to enhance the knowledge about NTM in our country and indicates the importance of faster NTM identification, as well as the importance of good communication between laboratory personnel and physicians when evaluating the significance of the isolated NTM.
Collapse
Affiliation(s)
- Marija Zlojtro
- Department for Respiratory Diseases, General Hospital Zabok, Bracak 8, 49210 Zabok, Croatia
| | - Mateja Jankovic
- Department for Respiratory Diseases, University Hospital Centre Zagreb, Jordanovac 104, 10000 Zagreb, Croatia E-mail:
| | - Miroslav Samarzija
- Department for Respiratory Diseases, University of Zagreb Medical School, University Hospital Centre, Salata 3 10000 Zagreb, Croatia
| | - Ljiljana Zmak
- National Mycobacterial Reference Laboratory, Croatian National Institute of Public Health, Zagreb, Rockefellerova ulica 7, 10000 Zagreb, Croatia
| | - Vera Katalinic Jankovic
- National Mycobacterial Reference Laboratory, Croatian National Institute of Public Health, Zagreb, Rockefellerova ulica 7, 10000 Zagreb, Croatia
| | - Mihaela Obrovac
- National Mycobacterial Reference Laboratory, Croatian National Institute of Public Health, Zagreb, Rockefellerova ulica 7, 10000 Zagreb, Croatia
| | - Igor Zlojtro
- University of Zagreb Medical School, Salata 3, 10000 Zagreb, Croatia
| | - Marko Jakopovic
- Department for Respiratory Diseases, University of Zagreb Medical School, University Hospital Centre, Salata 3 10000 Zagreb, Croatia
| |
Collapse
|
84
|
Nontuberculous mycobacteria pathogenesis and biofilm assembly. Int J Mycobacteriol 2015; 4:36-43. [PMID: 26655196 DOI: 10.1016/j.ijmyco.2014.11.065] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2014] [Accepted: 11/30/2014] [Indexed: 11/22/2022] Open
Abstract
Nontuberculous mycobacteria (NTM) are emergent pathogens whose importance in human health has been gaining relevance after being recognized as etiological agents of opportunist infections in HIV patients. Currently, NTM are recognized as etiological agents of several respiratory and extra-respiratory infections of immune-competent individuals. The environmental nature of NTM together with the ability to assemble biofilms on different surfaces plays a key role on their pathogenesis. In the present work the ability of three fast-growing NTM (Mycobacterium smegmatis, Mycobacterium fortuitum and Mycobacterium chelonae) to persist within a model of human alveolar macrophages was evaluated. Most often human infections with NTM occur by contact with the environment. Biofilms can work as environmental reservoirs. For this reason, it was decided to evaluate the ability of NTM to assemble biofilms on different surfaces. Scanning electron microscopy was used to elucidate the biofilm structure. The ability to assemble biofilms was connected with the ability to spread on solid media known as sliding. Biofilm assembly and intracellular persistence seems to be ruled by different mechanisms.
Collapse
|
85
|
Changes in physicochemical properties and bactericidal efficiency of acidic electrolyzed water ice and available chlorine decay kinetics during storage. Lebensm Wiss Technol 2014. [DOI: 10.1016/j.lwt.2014.05.043] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
86
|
Taharaguchi M, Takimoto K, Zamoto-Niikura A, Yamada YK. Effect of weak acid hypochlorous solution on selected viruses and bacteria of laboratory rodents. Exp Anim 2014; 63:141-7. [PMID: 24770639 PMCID: PMC4160982 DOI: 10.1538/expanim.63.141] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Weak acid hypochlorous solution (WAHS) is known to have efficacy for inactivating
pathogens and to be relatively safe with respect to the live body. Based on these
advantages, many animal facilities have recently been introducing WAHS for daily cleaning
of animal houses. In this study, we determined the effect of WAHS in inactivating specific
pathogens of laboratory rodents and pathogens of opportunistic infection. WAHS with an
actual chloride concentration of 60 ppm and a pH value of 6.0 was generated using
purpose-built equipment. One volume of mouse hepatitis virus (MHV), Sendai virus,
lymphocytic choriomeningitis virus, Bordetella bronchiseptica,
Pasteurella pneumotropica, Corynebacterium kutscheri,
Staphylococcus aureus, and Pseudomonas aeruginosa was
mixed with 9 or 99 volumes of WAHS (×10 and ×100 reaction) for various periods (0.5, 1,
and 5 min) at 25°C. After incubation, the remaining infectious viruses and live bacteria
were determined by plaque assay or culture. In the ×100 reaction mixture, infectious
viruses and live bacteria could not be detected for any of the pathogens examined even
with the 0.5-min incubation. However, the effects for MHV, B.
bronchiseptica, and P. aeruginosa were variable in the ×10
reaction mixture with the 0.5- and 1-min incubations. Sufficient effects were obtained by
elongation of the reaction time to 5 min. In the case of MHV, reducing organic substances
in the virus stock resulted in the WAHS being completely effective. WAHS is recommended
for daily cleaning in animal facilities but should be used properly in order to obtain a
sufficient effect, which includes such things as using a large enough volume to reduce
effects of organic substances.
Collapse
|
87
|
Delafont V, Mougari F, Cambau E, Joyeux M, Bouchon D, Héchard Y, Moulin L. First evidence of amoebae-mycobacteria association in drinking water network. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:11872-82. [PMID: 25247827 DOI: 10.1021/es5036255] [Citation(s) in RCA: 75] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Free-living amoebae are protozoa ubiquitously found in water systems. They mainly feed on bacteria by phagocytosis, but some bacterial species are able to resist or even escape this lethal process. Among these amoeba resistant bacteria are numerous members of the genus Mycobacterium. Nontuberculous Mycobacteria (NTM) are opportunistic pathogens that share the same ecological niches as amoebae. While several studies have demonstrated the ability of these bacteria to colonise and persist within drinking water networks, there is also strong suspicion that mycobacteria could use amoebae as a vehicle for protection and even replication. We investigated here the presence of NTM and FLA on a drinking water network during an all year round sampling campaign. We observed that 87.6% of recovered amoebal cultures carried high numbers of NTM. Identification of these amoeba and mycobacteria strains indicated that the main genera found in drinking water networks, that is, Acanthamoeba, Vermamoeba, Echinamoeba, and Protacanthamoeba are able to carry and likely to allow replication of several environmental and potentially pathogenic mycobacteria including M. llatzerense and M. chelonae. Direct Sanger sequencing as well as pyrosequencing of environmental isolates demonstrated the frequent association of mycobacteria and FLA, as they are part of the most represented genera composing amoebae's microbiome. This is the first time that an association between FLA and NTM is observed in water networks, highlighting the importance of FLA in the ecology of NTM.
Collapse
Affiliation(s)
- Vincent Delafont
- Université de Poitiers , Laboratoire Ecologie et Biologie des Interactions, UMR CNRS 7267, Equipes Microbiologie de l'Eau & Ecologie, Evolution, Symbiose, Poitiers 86000, France
| | | | | | | | | | | | | |
Collapse
|
88
|
Kralik P, Babak V, Dziedzinska R. Repeated cycles of chemical and physical disinfection and their influence on Mycobacterium avium subsp. paratuberculosis viability measured by propidium monoazide F57 quantitative real time PCR. Vet J 2014; 201:359-64. [DOI: 10.1016/j.tvjl.2014.05.032] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2014] [Revised: 05/18/2014] [Accepted: 05/23/2014] [Indexed: 11/28/2022]
|
89
|
Heterogeneity of clinical and environmental isolates of Mycobacterium fortuitum using repetitive element sequence-based PCR: municipal water an unlikely source of community-acquired infections. Epidemiol Infect 2014; 142:2057-64. [PMID: 24398184 DOI: 10.1017/s0950268813003257] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
M. fortuitum is a rapidly growing mycobacterium associated with community-acquired and nosocomial wound, soft tissue, and pulmonary infections. It has been postulated that water has been the source of infection especially in the hospital setting. The aim of this study was to determine if municipal water may be the source of community-acquired or nosocomial infections in the Brisbane area. Between 2007 and 2009, 20 strains of M. fortuitum were recovered from municipal water and 53 patients' isolates were submitted to the reference laboratory. A wide variation in strain types was identified using repetitive element sequence-based PCR, with 13 clusters of ⩾2 indistinguishable isolates, and 28 patterns consisting of individual isolates. The clusters could be grouped into seven similar groups (>95% similarity). Municipal water and clinical isolates collected during the same time period and from the same geographical area consisted of different strain types, making municipal water an unlikely source of sporadic human infection.
Collapse
|
90
|
Hollm-Delgado MG, Stuart EA, Black RE. Acute lower respiratory infection among Bacille Calmette-Guérin (BCG)-vaccinated children. Pediatrics 2014; 133:e73-81. [PMID: 24379224 DOI: 10.1542/peds.2013-2218] [Citation(s) in RCA: 83] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE To determine whether Bacille Calmette-Guerin (BCG) vaccination is linked to the risk of acute lower respiratory infection (ALRI) among children <5 years of age. METHODS Data from Macro International Demographic and Health Surveys and United Nations Children's Fund Multiple Indicator Cluster Surveys were used to identify a primary cohort of 58,021 children in 19 countries (2005-2010) and a secondary cohort of 93,301 children in 18 countries (2000-2007). Information was collected by trained interviewers during home visits using standardized questionnaires, review of vaccination health cards, and measurement of health indicators. RESULTS BCG vaccination was associated with a 17% to 37% risk reduction for suspected ALRI in both cohorts. The only vaccine or vitamin supplement to modify the effect of BCG was diphtheria-tetanus-pertussis (DTP; P < .001). The order in which the vaccines were first received was central to this phenomena (BCG before DTP, adjusted/propensity score-weighted relative risk [apRR]: 0.79, 95% confidence interval [CI]: 0.70-0.89; BCG with DTP, apRR: 0.82, 95% CI: 0.71-0.94; and BCG after DTP, apRR: 1.00, 95% CI: 0.87-1.13) but not number of DTP doses received. Other modifiers included vaccine strain used in immunization programs, chlorinating drinking water, using wood-burning fuel cook stoves, and owning livestock. CONCLUSIONS Children vaccinated with BCG had a significantly lower risk of suspected ALRI. Clarification is needed as to whether this is due to reductions in the underlying risk of tuberculosis or ALRI per se.
Collapse
Affiliation(s)
- Maria-Graciela Hollm-Delgado
- Department of International Health, Johns Hopkins Bloomberg School of Public Health, 615 North Wolfe St, Baltimore, MD 21205.
| | | | | |
Collapse
|
91
|
Brugnera MF, Miyata M, Zocolo GJ, Leite CQF, Zanoni MVB. A photoelectrocatalytic process that disinfects water contaminated with Mycobacterium kansasii and Mycobacterium avium. WATER RESEARCH 2013; 47:6596-605. [PMID: 24079966 DOI: 10.1016/j.watres.2013.08.027] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2013] [Revised: 08/21/2013] [Accepted: 08/24/2013] [Indexed: 05/03/2023]
Abstract
Nontuberculous mycobacteria are resistant to conventional water treatment; indeed, they have been recovered from a wide variety of environmental sources. Here, we applied the photoelectrocatalytic technique using a Ti/TiO2-Ag photoanode to inactivate mycobacteria. For a mycobacteria population of 5 × 10(8) CFU mL(-1), we achieved 99.9 and 99.8% inactivation of Mycobacterium kansasii and Mycobacterium avium with rate constant of 6.2 × 10(-3) and 4.2 × 10(-3) min(-1), respectively, after 240 min. We compared the proposed method with the photolytic and photocatalytic methods. Using a mycobacteria population of 7.5 × 10(4) CFU mL(-1), the proposed Ti/TiO2-Ag photoanode elicited total mycobacteria inactivation within 3 min of treatment; the presence of Ag nanoparticles in the electrode provided 1.5 larger degradation rate constant as compared with the Ti/TiO2 anode (1.75 × 10(-2) for M. kansassi and 1.98 × 10(-2) for M. avium). We monitored the degradation of the metabolites released during cellular lysis by TOC removal, sugar release, chromatography, and mass spectrometry measurements; photoelectrocatalysis and Ti/TiO2-Ag photoanodes furnished the best results.
Collapse
Affiliation(s)
- Michelle Fernanda Brugnera
- Department of Analytical Chemistry, Institute of Chemistry of Araraquara, UNESP, Rua Francisco Degni, 55 - Bairro Quitandinha, 14800-900 Araraquara, SP, Brazil.
| | | | | | | | | |
Collapse
|
92
|
de Sousa KBA, da Silva TRR, Alencar RB, Baton LA, Naveca FG, Shimabukuro PHF. 16S rRNA gene-based identification of microbiota associated with the parthenogenetic troglobiont sand fly Deanemyia maruaga (Diptera, Psychodidae) from central Amazon, Brazil. Braz J Microbiol 2013; 44:325-8. [PMID: 24159323 PMCID: PMC3804217 DOI: 10.1590/s1517-83822013005000013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2011] [Accepted: 07/02/2012] [Indexed: 02/01/2023] Open
Abstract
Bacteria associated with the parthenogenetic troglobiont sand fly Deanemyia maruaga were characterized by sequencing cloned 16S rDNA PCR products. Eleven novel partial 16S rDNA sequences, with varying degrees of similarity to Actinobacteria, were identified. None of the sequences identified had homology to those known from parthenogenesis-inducing bacteria.
Collapse
|
93
|
Wang H, Pryor MA, Edwards MA, Falkinham JO, Pruden A. Effect of GAC pre-treatment and disinfectant on microbial community structure and opportunistic pathogen occurrence. WATER RESEARCH 2013; 47:5760-72. [PMID: 23906775 DOI: 10.1016/j.watres.2013.06.052] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2012] [Revised: 06/21/2013] [Accepted: 06/27/2013] [Indexed: 05/10/2023]
Abstract
Opportunistic pathogens in potable water systems are an emerging health concern; however, the factors influencing their proliferation are poorly understood. Here we investigated the effects of prior granular activated carbon (GAC) biofiltration [GAC-filtered water, unfiltered water, and a blend (30% GAC filtered and 70% unfiltered water)] and disinfectant type (chlorine, chloramine) on opportunistic pathogen occurrence using five annular reactors (ARs) to simulate water distribution systems, particularly premise plumbing. GAC pre-treatment effectively reduced total organic carbon (TOC), resulting in three levels of influent TOC investigated. Quantitative polymerase chain reaction (q-PCR) provided molecular evidence of natural colonization of Legionella spp., Mycobacterium spp., Acanthamoeba spp., Hartmannella vermiformis and Mycobacterium avium on AR coupons. Cultivable mycobacteria and amoeba, including pathogenic species, were also found in bulk water and biofilm samples. While q-PCR tends to overestimate live cells, it provided a quantitative comparison of target organisms colonizing the AR biofilms in terms of gene copy numbers. In most cases, total bacteria and opportunistic pathogens were higher in the three undisinfected ARs, but the levels were not proportional to the level of GAC pre-treatment/TOC. Chlorine was more effective for controlling mycobacteria and Acanthamoeba, whereas chloramine was more effective for controlling Legionella. Both chlorine and chloramine effectively inhibited M. avium and H. vermiformis colonization. Pyrosequencing of 16S rRNA genes in coupon biofilms revealed a significant effect of GAC pre-treatment and disinfectant type on the microbial community structure. Overall, this study provides insights into the potential of different disinfectants and GAC biofilters at the treatment plant and in buildings to control downstream opportunistic pathogens and broader drinking water microbial communities.
Collapse
Affiliation(s)
- Hong Wang
- Via Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA 24061, USA
| | | | | | | | | |
Collapse
|
94
|
Wang S, Huang J, Yang Y, Hui Y, Ge Y, Larssen T, Yu G, Deng S, Wang B, Harman C. First report of a Chinese PFOS alternative overlooked for 30 years: its toxicity, persistence, and presence in the environment. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2013; 47:10117-28. [PMID: 23952109 DOI: 10.1021/es402455r] [Citation(s) in RCA: 105] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
This is the first report on the environmental occurrence of a chlorinated polyfluorinated ether sulfonate (locally called F-53B, C8ClF16O4SK). It has been widely applied as a mist suppressant by the chrome plating industry in China for decades but has evaded the attention of environmental research and regulation. In this study, F-53B was found in high concentrations (43-78 and 65-112 μg/L for the effluent and influent, respectively) in wastewater from the chrome plating industry in the city of Wenzhou, China. F-53B was not successfully removed by the wastewater treatments in place. Consequently, it was detected in surface water that receives the treated wastewater at similar levels to PFOS (ca. 10-50 ng/L) and the concentration decreased with the increasing distance from the wastewater discharge point along the river. Initial data presented here suggest that F-53B is moderately toxic (Zebrafish LC50-96 h 15.5 mg/L) and is as resistant to degradation as PFOS. While current usage is limited to the chrome plating industry, the increasing demand for PFOS alternatives in other sectors may result in expanded usage. Collectively, the results of this work call for future assessments on the effects of this overlooked contaminant and its presence and fate in the environment.
Collapse
Affiliation(s)
- Siwen Wang
- State Key Joint Laboratory of Environment Simulation and Pollution Control (SKJLESPC), School of Environment, POPs Research Centre, Tsinghua University , Beijing 100084, P.R. China
| | | | | | | | | | | | | | | | | | | |
Collapse
|
95
|
Zhang Y, Hunt HK, Hu Z. Application of bacteriophages to selectively remove Pseudomonas aeruginosa in water and wastewater filtration systems. WATER RESEARCH 2013; 47:4507-4518. [PMID: 23764600 DOI: 10.1016/j.watres.2013.05.014] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2013] [Revised: 05/07/2013] [Accepted: 05/09/2013] [Indexed: 06/02/2023]
Abstract
Water and wastewater filtration systems often house pathogenic bacteria, which must be removed to ensure clean, safe water. Here, we determine the persistence of the model bacterium Pseudomonas aeruginosa in two types of filtration systems, and use P. aeruginosa bacteriophages to determine their ability to selectively remove P. aeruginosa. These systems used beds of either anthracite or granular activated carbon (GAC), which were operated at an empty bed contact time (EBCT) of 45 min. The clean bed filtration systems were loaded with an instantaneous dose of P. aeruginosa at a total cell number of 2.3 (± 0.1 [standard deviation]) × 10(7) cells. An immediate dose of P. aeruginosa phages (1 mL of phage stock at the concentration of 2.7 × 10(7) PFU (Plaque Forming Units)/mL) resulted in a reduction of 50% (± 9%) and >99.9% in the effluent P. aeruginosa concentrations in the clean anthracite and GAC filters, respectively. To further evaluate the effects of P. aeruginosa phages, synthetic stormwater was run through anthracite and GAC biofilters where mixed-culture biofilms were present. Eighty five days after an instantaneous dose of P. aeruginosa (2.3 × 10(7) cells per filter) on day 1, 7.5 (± 2.8) × 10(7) and 1.1 (± 0.5) × 10(7) P. aeruginosa cells/g filter media were detected in the top layer (close to the influent port) of the anthracite and GAC biofilters, respectively, demonstrating the growth and persistence of pathogenic bacteria in the biofilters. A subsequent 1-h dose of phages, at the concentration of 5.1 × 10(6) PFU/mL and flow rate of 1.6 mL/min, removed the P. aeruginosa inside the GAC biofilters and the anthracite biofilters by 70% (± 5%) and 56% (± 1%), respectively, with no P. aeruginosa detected in the effluent, while not affecting ammonia oxidation or the ammonia-oxidizing bacterial community inside the biofilters. These results suggest that phage treatment can selectively remove pathogenic bacteria with minimal impact on beneficial organisms from attached growth systems for effluent quality improvement.
Collapse
Affiliation(s)
- Yanyan Zhang
- Department of Civil and Environmental Engineering, University of Missouri, E2509 Lafferre Hall, Columbia, MO 65211, USA
| | | | | |
Collapse
|
96
|
Diversity, community composition, and dynamics of nonpigmented and late-pigmenting rapidly growing mycobacteria in an urban tap water production and distribution system. Appl Environ Microbiol 2013; 79:5498-508. [PMID: 23835173 DOI: 10.1128/aem.00900-13] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Nonpigmented and late-pigmenting rapidly growing mycobacteria (RGM) have been reported to commonly colonize water production and distribution systems. However, there is little information about the nature and distribution of RGM species within the different parts of such complex networks or about their clustering into specific RGM species communities. We conducted a large-scale survey between 2007 and 2009 in the Parisian urban tap water production and distribution system. We analyzed 1,418 water samples from 36 sites, covering all production units, water storage tanks, and distribution units; RGM isolates were identified by using rpoB gene sequencing. We detected 18 RGM species and putative new species, with most isolates being Mycobacterium chelonae and Mycobacterium llatzerense. Using hierarchical clustering and principal-component analysis, we found that RGM were organized into various communities correlating with water origin (groundwater or surface water) and location within the distribution network. Water treatment plants were more specifically associated with species of the Mycobacterium septicum group. On average, M. chelonae dominated network sites fed by surface water, and M. llatzerense dominated those fed by groundwater. Overall, the M. chelonae prevalence index increased along the distribution network and was associated with a correlative decrease in the prevalence index of M. llatzerense, suggesting competitive or niche exclusion between these two dominant species. Our data describe the great diversity and complexity of RGM species living in the interconnected environments that constitute the water production and distribution system of a large city and highlight the prevalence index of the potentially pathogenic species M. chelonae in the distribution network.
Collapse
|
97
|
|
98
|
Ortega-Gómez E, Fernández-Ibáñez P, Ballesteros Martín MM, Polo-López MI, Esteban García B, Sánchez Pérez JA. Water disinfection using photo-Fenton: Effect of temperature on Enterococcus faecalis survival. WATER RESEARCH 2012; 46:6154-6162. [PMID: 23021523 DOI: 10.1016/j.watres.2012.09.007] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/29/2012] [Revised: 05/24/2012] [Accepted: 09/04/2012] [Indexed: 06/01/2023]
Abstract
The photo-Fenton process is a promising alternative to classical water disinfection treatments, although information in this regard is scarce due to its operational limitations. The effect of temperature (10, 20, 30 and 40 °C) was studied on water disinfection using the photo-Fenton reaction at initial near neutral pH with resorcinol as a model of natural organic matter (NOM). Enterococcus faecalis, a Gram-positive microorganism, was selected as an indicator of wastewater faecal contamination. The individual effects of different variables involved in this process (mechanical stress, UVA, H(2)O(2), Fe(2+), H(2)O(2)/Fe(2+), UVA/Fe(2+), UVA/H(2)O(2) and UVA/H(2)O(2)/Fe(2+)) were determined. UVA and H(2)O(2) led to a 2.5-log decrease individually and the combined effect of both variables managed to disinfect up to the detection limit (i.e. from a 5.5 to a 6-log reduction) over the same treatment time. Only by adding 10 mg L(-1) of Fe(2+), the inactivation time was reduced from 120 min (H(2)O(2)/UVA) to 80 min (H(2)O(2)/UVA/Fe(2+); photo-Fenton) with 120 mg L(-1) of H(2)O(2). A higher disinfection result for E. faecalis was observed by increasing temperature according to the Arrhenius equation in the photo-Fenton process. The detection limit was not reached at 10 °C and, to achieve the detection limit at 20, 30 and 40 °C, 80, 65 and 40 min were needed, respectively. The decrease in treatment time is a key factor in applying the photo-Fenton disinfection process to a wastewater treatment plant.
Collapse
Affiliation(s)
- E Ortega-Gómez
- Department of Chemical Engineering, University of Almería, La Cañada de San Urbano, 04120 Almería, Spain
| | | | | | | | | | | |
Collapse
|
99
|
Wang H, Masters S, Hong Y, Stallings J, Falkinham JO, Edwards MA, Pruden A. Effect of disinfectant, water age, and pipe material on occurrence and persistence of Legionella, mycobacteria, Pseudomonas aeruginosa, and two amoebas. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2012; 46:11566-74. [PMID: 23046164 DOI: 10.1021/es303212a] [Citation(s) in RCA: 113] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Opportunistic pathogens represent a unique challenge because they establish and grow within drinking water systems, yet the factors stimulating their proliferation are largely unknown. The purpose of this study was to examine the influence of pipe materials, disinfectant type, and water age on occurrence and persistence of three opportunistic pathogens (Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa), broader genera (Legionella and mycobacteria), and two amoeba hosts (Acanthamoeba spp. and Hartmanella vermiformis). Triplicate simulated distribution systems (SDSs) compared iron, cement, and PVC pipe materials fed either chlorinated or chloraminated tap water and were sampled at water ages ranging from 1 day to 5.7 days. Quantitative polymerase chain reaction quantified gene copies of target microorganisms in both biofilm and bulk water. Legionella, mycobacteria, P. aeruginosa, and both amoebas naturally colonized the six SDSs, but L. pneumophila and M. avium were not detected. Disinfectant type and dose was observed to have the strongest influence on the microbiota. Disinfectant decay was noted with water age, particularly in chloraminated SDSs (due to nitrification), generally resulting in increased microbial detection frequencies and densities with water age. The influence of pipe material became apparent at water ages corresponding to low disinfectant residual. Each target microbe appeared to display a distinct response to disinfectant type, pipe materials, water age, and their interactions. Differences between the first and the second samplings (e.g., appearance of Legionella, reduction in P. aeruginosa and Acanthamoeba) suggest a temporally dynamic drinking water microbial community.
Collapse
Affiliation(s)
- Hong Wang
- Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, USA
| | | | | | | | | | | | | |
Collapse
|
100
|
Ling F, Liu WT. Impact of chloramination on the development of laboratory-grown biofilms fed with filter-pretreated groundwater. Microbes Environ 2012; 28:50-7. [PMID: 23124766 PMCID: PMC4070696 DOI: 10.1264/jsme2.me12095] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2012] [Accepted: 07/23/2012] [Indexed: 11/30/2022] Open
Abstract
This study evaluated the continuous impact of monochloramine disinfection on laboratory-grown biofilms through the characterization of biofilm architecture and microbial community structure. Biofilm development and disinfection were achieved using CDC (Centers for Disease Control and Prevention) biofilm reactor systems with polyvinyl chloride (PVC) coupons as the substratum and sand filter-pretreated groundwater as the source of microbial seeding and growth nutrient. After 2 weeks of growth, the biofilms were subjected to chloramination for 8 more weeks at concentrations of 7.5±1.4 to 9.1±0.4 mg Cl2 L(-1). Control reactors received no disinfection during the development of biofilms. Confocal laser scanning microscopy and image analysis indicated that chloramination could lead to 81.4-83.5% and 86.3-95.6% reduction in biofilm biomass and thickness, respectively, but could not eliminate biofilm growth. 16S rRNA gene terminal restriction fragment length polymorphism analysis indicated that microbial community structures between chloraminated and non-chloraminated biofilms exhibited different successional trends. 16S rRNA gene pyrosequencing analysis further revealed that chloramination could select members of Actinobacteria and Acidobacteria as the dominant populations, whereas natural development leads to the selection of members of Nitrospira and Bacteroidetes as dominant biofilm populations. Overall, chloramination treatment could alter the growth of multi-species biofilms on the PVC surface, shape the biofilm architecture, and select a certain microbial community that can survive or proliferate under chloramination.
Collapse
Affiliation(s)
- Fangqiong Ling
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, 205 N. Mathews Ave., Urbana, Illinois 61801–2352, USA
| | - Wen-Tso Liu
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, 205 N. Mathews Ave., Urbana, Illinois 61801–2352, USA
| |
Collapse
|