51
|
Palai D, Tahara H, Chikami S, Latag GV, Maeda S, Komura C, Kurioka H, Hayashi T. Prediction of Serum Adsorption onto Polymer Brush Films by Machine Learning. ACS Biomater Sci Eng 2022; 8:3765-3772. [PMID: 35905395 DOI: 10.1021/acsbiomaterials.2c00441] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Using machine learning based on a random forest (RF) regression algorithm, we attempted to predict the amount of adsorbed serum protein on polymer brush films from the films' physicochemical information and the monomers' chemical structures constituting the films using a RF model. After the training of the RF model using the data of polymer brush films synthesized from five different types of monomers, the model became capable of predicting the amount of adsorbed protein from the chemical structure, physicochemical properties of monomer molecules, and structural parameters (density and thickness of the films). The analysis of the trained RF quantitatively provided the importance of each structural parameter and physicochemical properties of monomers toward serum protein adsorption (SPA). The ranking for the significance of the parameters agrees with our general understanding and perception. Based on the results, we discuss the correlation between brush film's physical properties (such as thickness and density) and SPA and attempt to provide a guideline for the design of antibiofouling polymer brush films.
Collapse
Affiliation(s)
- Debabrata Palai
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 4259 Nagatsuta-Cho Midori-Ku, Yokohama, Kanagawa 226-8502, Japan
| | - Hiroyuki Tahara
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 4259 Nagatsuta-Cho Midori-Ku, Yokohama, Kanagawa 226-8502, Japan
| | - Shunta Chikami
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 4259 Nagatsuta-Cho Midori-Ku, Yokohama, Kanagawa 226-8502, Japan
| | - Glenn Villena Latag
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 4259 Nagatsuta-Cho Midori-Ku, Yokohama, Kanagawa 226-8502, Japan
| | - Shoichi Maeda
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 4259 Nagatsuta-Cho Midori-Ku, Yokohama, Kanagawa 226-8502, Japan
| | - Chisato Komura
- Research Institute for Advanced Materials and Devices, Kyocera Corporation, 3-5-3 Hikaridai, Seika-Cho, Soraku-gun, Kyoto 619-0237, Japan
| | - Hideharu Kurioka
- Research Institute for Advanced Materials and Devices, Kyocera Corporation, 3-5-3 Hikaridai, Seika-Cho, Soraku-gun, Kyoto 619-0237, Japan
| | - Tomohiro Hayashi
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 4259 Nagatsuta-Cho Midori-Ku, Yokohama, Kanagawa 226-8502, Japan.,The Institute for Solid State Physics, the University of Tokyo, 5-1-5, Kashiwanoha, Kashiwa, Chiba, 277-0882, Japan
| |
Collapse
|
52
|
Asymmetric Mach–Zehnder Interferometric Biosensing for Quantitative and Sensitive Multiplex Detection of Anti-SARS-CoV-2 Antibodies in Human Plasma. BIOSENSORS 2022; 12:bios12080553. [PMID: 35892450 PMCID: PMC9394312 DOI: 10.3390/bios12080553] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 07/20/2022] [Accepted: 07/20/2022] [Indexed: 12/11/2022]
Abstract
The Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) pandemic has once more emphasized the urgent need for accurate and fast point-of-care (POC) diagnostics for outbreak control and prevention. The main challenge in the development of POC in vitro diagnostics (IVD) is to combine a short time to result with a high sensitivity, and to keep the testing cost-effective. In this respect, sensors based on photonic integrated circuits (PICs) may offer advantages as they have features such as a high analytical sensitivity, capability for multiplexing, ease of miniaturization, and the potential for high-volume manufacturing. One special type of PIC sensor is the asymmetric Mach–Zehnder Interferometer (aMZI), which is characterized by a high and tunable analytical sensitivity. The current work describes the application of an aMZI-based biosensor platform for sensitive and multiplex detection of anti-SARS-CoV-2 antibodies in human plasma samples using the spike protein (SP), the receptor-binding domain (RBD), and the nucleocapsid protein (NP) as target antigens. The results are in good agreement with several CE-IVD marked reference methods and demonstrate the potential of the aMZI biosensor technology for further development into a photonic IVD platform.
Collapse
|
53
|
Mazzotta E, Di Giulio T, Malitesta C. Electrochemical sensing of macromolecules based on molecularly imprinted polymers: challenges, successful strategies, and opportunities. Anal Bioanal Chem 2022; 414:5165-5200. [PMID: 35277740 PMCID: PMC8916950 DOI: 10.1007/s00216-022-03981-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 02/08/2022] [Accepted: 02/15/2022] [Indexed: 12/21/2022]
Abstract
Looking at the literature focused on molecularly imprinted polymers (MIPs) for protein, it soon becomes apparent that a remarkable increase in scientific interest and exploration of new applications has been recorded in the last several years, from 42 documents in 2011 to 128 just 10 years later, in 2021 (Scopus, December 2021). Such a rapid threefold increase in the number of works in this field is evidence that the imprinting of macromolecules no longer represents a distant dream of optimistic imprinters, as it was perceived until only a few years ago, but is rapidly becoming an ever more promising and reliable technology, due to the significant achievements in the field. The present critical review aims to summarize some of them, evidencing the aspects that have contributed to the success of the most widely used strategies in the field. At the same time, limitations and drawbacks of less frequently used approaches are critically discussed. Particular focus is given to the use of a MIP for protein in the assembly of electrochemical sensors. Sensor design indeed represents one of the most active application fields of imprinting technology, with electrochemical MIP sensors providing the broadest spectrum of protein analytes among the different sensor configurations.
Collapse
Affiliation(s)
- Elisabetta Mazzotta
- Laboratory of Analytical Chemistry, Department of Biological and Environmental Sciences and Technologies (Di.S.Te.B.A.), University of Salento, via Monteroni, 73100, Lecce, Italy.
| | - Tiziano Di Giulio
- Laboratory of Analytical Chemistry, Department of Biological and Environmental Sciences and Technologies (Di.S.Te.B.A.), University of Salento, via Monteroni, 73100, Lecce, Italy
| | - Cosimino Malitesta
- Laboratory of Analytical Chemistry, Department of Biological and Environmental Sciences and Technologies (Di.S.Te.B.A.), University of Salento, via Monteroni, 73100, Lecce, Italy
| |
Collapse
|
54
|
Szittner Z, Péter B, Kurunczi S, Székács I, Horváth R. Functional blood cell analysis by label-free biosensors and single-cell technologies. Adv Colloid Interface Sci 2022; 308:102727. [DOI: 10.1016/j.cis.2022.102727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 05/25/2022] [Accepted: 06/27/2022] [Indexed: 11/01/2022]
|
55
|
Ultra-wide, attomolar-level limit detection of CD44 biomarker with a silanized optical fiber biosensor. Biosens Bioelectron 2022; 208:114217. [DOI: 10.1016/j.bios.2022.114217] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 03/02/2022] [Accepted: 03/22/2022] [Indexed: 12/15/2022]
|
56
|
Almehmadi LM, Valsangkar VA, Halvorsen K, Zhang Q, Sheng J, Lednev IK. Surface-enhanced Raman spectroscopy for drug discovery: peptide-RNA binding. Anal Bioanal Chem 2022; 414:6009-6016. [PMID: 35764806 PMCID: PMC9404289 DOI: 10.1007/s00216-022-04190-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2022] [Revised: 06/06/2022] [Accepted: 06/21/2022] [Indexed: 11/01/2022]
Abstract
The ever-growing demand for new drugs highlights the need to develop novel cost- and time-effective techniques for drug discovery. Surface-enhanced Raman spectroscopy (SERS) is an emerging ultrasensitive and label-free technique that allows for the efficient detection and characterization of molecular interactions. We have recently developed a SERS platform for detecting a single protein molecule linked to a gold substrate (Almehmadi et al. Scientific Reports 2019). In this study, we extended the approach to probe the binding of potential drugs to RNA targets. To demonstrate the proof of concept, two 16-amino acid residue peptides with close primary structures and different binding affinities to the RNA CUG repeat related to myotonic dystrophy were tested. Three-microliter solutions of the RNA repeat with these peptides at nanomolar concentrations were probed using the developed approach, and the binding of only one peptide was demonstrated. The SER spectra exhibited significant fluctuations along with a sudden strong enhancement as spectra were collected consecutively from individual spots. Principal component analysis (PCA) of the SER spectral datasets indicated that free RNA repeats could be differentiated from those complexed with a peptide with 100% accuracy. The developed SERS platform provides a novel opportunity for label-free screening of RNA-binding peptides for drug discovery. Schematic representation of the SERS platform for drug discovery developed in this study.
Collapse
Affiliation(s)
- Lamyaa M Almehmadi
- Department of Chemistry, University at Albany, SUNY, 1400 Washington Avenue, Albany, NY, 12222, USA.,College of Arts and Science, RNA Institute, University at Albany, SUNY, 1400 Washington Avenue, Albany, NY, 12222, USA
| | - Vibhav A Valsangkar
- Department of Chemistry, University at Albany, SUNY, 1400 Washington Avenue, Albany, NY, 12222, USA.,College of Arts and Science, RNA Institute, University at Albany, SUNY, 1400 Washington Avenue, Albany, NY, 12222, USA
| | - Ken Halvorsen
- College of Arts and Science, RNA Institute, University at Albany, SUNY, 1400 Washington Avenue, Albany, NY, 12222, USA
| | - Qiang Zhang
- Department of Chemistry, University at Albany, SUNY, 1400 Washington Avenue, Albany, NY, 12222, USA
| | - Jia Sheng
- Department of Chemistry, University at Albany, SUNY, 1400 Washington Avenue, Albany, NY, 12222, USA. .,College of Arts and Science, RNA Institute, University at Albany, SUNY, 1400 Washington Avenue, Albany, NY, 12222, USA.
| | - Igor K Lednev
- Department of Chemistry, University at Albany, SUNY, 1400 Washington Avenue, Albany, NY, 12222, USA. .,College of Arts and Science, RNA Institute, University at Albany, SUNY, 1400 Washington Avenue, Albany, NY, 12222, USA.
| |
Collapse
|
57
|
Self-assembly of highly ordered micro- and nanoparticle deposits. Nat Commun 2022; 13:3085. [PMID: 35654770 PMCID: PMC9163176 DOI: 10.1038/s41467-022-30660-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Accepted: 05/06/2022] [Indexed: 11/08/2022] Open
Abstract
The evaporation of particle-laden sessile droplets is associated with capillary-driven outward flow and leaves nonuniform coffee-ring-like particle patterns due to far-from-equilibrium effects. Traditionally, the surface energies of the drop and solid phases are tuned, or external forces are applied to suppress the coffee-ring; however, achieving a uniform and repeatable particle deposition is extremely challenging. Here, we report a simple, scalable, and noninvasive technique that yields uniform and exceptionally ordered particle deposits on a microscale surface area by placing the droplet on a near neutral-wet shadow mold attached to a hydrophilic substrate. The simplicity of the method, no external forces, and no tuning materials' physiochemical properties make the present generic approach an excellent candidate for a wide range of sensitive applications. We demonstrate the utility of this method for fabricating ordered mono- and multilayer patternable coatings, producing nanofilters with controlled pore size, and creating reproducible functionalized nanosensors.
Collapse
|
58
|
Guselnikova O, Lim H, Kim HJ, Kim SH, Gorbunova A, Eguchi M, Postnikov P, Nakanishi T, Asahi T, Na J, Yamauchi Y. New Trends in Nanoarchitectured SERS Substrates: Nanospaces, 2D Materials, and Organic Heterostructures. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2107182. [PMID: 35570326 DOI: 10.1002/smll.202107182] [Citation(s) in RCA: 50] [Impact Index Per Article: 25.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Revised: 03/23/2022] [Indexed: 06/15/2023]
Abstract
This article reviews recent fabrication methods for surface-enhanced Raman spectroscopy (SERS) substrates with a focus on advanced nanoarchitecture based on noble metals with special nanospaces (round tips, gaps, and porous spaces), nanolayered 2D materials, including hybridization with metallic nanostructures (NSs), and the contemporary repertoire of nanoarchitecturing with organic molecules. The use of SERS for multidisciplinary applications has been extensively investigated because the considerably enhanced signal intensity enables the detection of a very small number of molecules with molecular fingerprints. Nanoarchitecture strategies for the design of new NSs play a vital role in developing SERS substrates. In this review, recent achievements with respect to the special morphology of metallic NSs are discussed, and future directions are outlined for the development of available NSs with reproducible preparation and well-controlled nanoarchitecture. Nanolayered 2D materials are proposed for SERS applications as an alternative to the noble metals. The modern solutions to existing limitations for their applications are described together with the state-of-the-art in bio/environmental SERS sensing using 2D materials-based composites. To complement the existing toolbox of plasmonic inorganic NSs, hybridization with organic molecules is proposed to improve the stability of NSs and selectivity of SERS sensing by hybridizing with small or large organic molecules.
Collapse
Affiliation(s)
- Olga Guselnikova
- JST-ERATO Yamauchi Materials Space Tectonics Project, National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba, Ibaraki, 305-0044, Japan
- Research School of Chemistry and Applied Biomedical Sciences, Tomsk Polytechnic University, Tomsk, 634050, Russian Federation
| | - Hyunsoo Lim
- Australian Institute for Bioengineering and Nanotechnology (AIBN), The University of Queensland, Brisbane, QLD, 4072, Australia
- New & Renewable Energy Research Center, Korea Electronics Technology Institute (KETI), 25, Saenari-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 13509, Republic of Korea
| | - Hyun-Jong Kim
- Surface Technology Group, Korea Institute of Industrial Technology (KITECH), Incheon, 21999, Republic of Korea
| | - Sung Hyun Kim
- New & Renewable Energy Research Center, Korea Electronics Technology Institute (KETI), 25, Saenari-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 13509, Republic of Korea
| | - Alina Gorbunova
- Research School of Chemistry and Applied Biomedical Sciences, Tomsk Polytechnic University, Tomsk, 634050, Russian Federation
| | - Miharu Eguchi
- JST-ERATO Yamauchi Materials Space Tectonics Project, National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba, Ibaraki, 305-0044, Japan
| | - Pavel Postnikov
- Research School of Chemistry and Applied Biomedical Sciences, Tomsk Polytechnic University, Tomsk, 634050, Russian Federation
| | - Takuya Nakanishi
- Kagami Memorial Research Institute for Materials Science and Technology, Waseda University, 2-8-26 Nishiwaseda, Shinjuku, Tokyo, 169-0051, Japan
| | - Toru Asahi
- Kagami Memorial Research Institute for Materials Science and Technology, Waseda University, 2-8-26 Nishiwaseda, Shinjuku, Tokyo, 169-0051, Japan
| | - Jongbeom Na
- Australian Institute for Bioengineering and Nanotechnology (AIBN), The University of Queensland, Brisbane, QLD, 4072, Australia
- Research and Development (R&D) Division, Green Energy Institute, Mokpo, Jeollanamdo, 58656, Republic of Korea
| | - Yusuke Yamauchi
- JST-ERATO Yamauchi Materials Space Tectonics Project, National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba, Ibaraki, 305-0044, Japan
- Australian Institute for Bioengineering and Nanotechnology (AIBN), The University of Queensland, Brisbane, QLD, 4072, Australia
- Kagami Memorial Research Institute for Materials Science and Technology, Waseda University, 2-8-26 Nishiwaseda, Shinjuku, Tokyo, 169-0051, Japan
| |
Collapse
|
59
|
Ishihara K, Fukazawa K. Cell-membrane-inspired polymers for constructing biointerfaces with efficient molecular recognition. J Mater Chem B 2022; 10:3397-3419. [PMID: 35389394 DOI: 10.1039/d2tb00242f] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Fabrication of devices that accurately recognize, detect, and separate target molecules from mixtures is a crucial aspect of biotechnology for applications in medical, pharmaceutical, and food sciences. This technology has also been recently applied in solving environmental and energy-related problems. In molecular recognition, biomolecules are typically complexed with a substrate, and specific molecules from a mixture are recognized, captured, and reacted. To increase sensitivity and efficiency, the activity of the biomolecules used for capture should be maintained, and non-specific reactions on the surface should be prevented. This review summarizes polymeric materials that are used for constructing biointerfaces. Precise molecular recognition occurring at the surface of cell membranes is fundamental to sustaining life; therefore, materials that mimic the structure and properties of this particular surface are emphasized in this article. The requirements for biointerfaces to eliminate nonspecific interactions of biomolecules are described. In particular, the major issue of protein adsorption on biointerfaces is discussed by focusing on the structure of water near the interface from a thermodynamic viewpoint; moreover, the structure of polymer molecules that control the water structure is considered. Methodologies enabling stable formation of these interfaces on material surfaces are also presented.
Collapse
Affiliation(s)
- Kazuhiko Ishihara
- Department of Materials Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
| | - Kyoko Fukazawa
- Department of Materials Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
| |
Collapse
|
60
|
Pandey R, Lu Y, Osman E, Saxena S, Zhang Z, Qian S, Pollinzi A, Smieja M, Li Y, Soleymani L, Hoare T. DNAzyme-Immobilizing Microgel Magnetic Beads Enable Rapid, Specific, Culture-Free, and Wash-Free Electrochemical Quantification of Bacteria in Untreated Urine. ACS Sens 2022; 7:985-994. [PMID: 35384648 DOI: 10.1021/acssensors.1c02440] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Rapid, ultrasensitive, and specific detection and identification of bacteria in unprocessed clinical specimens is critically needed to enable point-of-care diagnosis of infectious diseases. However, existing systems require sample processing and/or analyte enrichment for direct bacterial analysis in clinical samples, which significantly adds to the assay time and complexity. Herein, we integrate RNA-cleaving DNAzymes specific to Escherichia coli (E. coli) and programmed for electrochemical signal transduction, multifunctional microgel magnetic beads for immobilizing the DNAzyme into a hydrated and three-dimensional scaffold, and hierarchical electrodes for ultrasensitive electrochemical readout to achieve rapid bacterial analysis in undiluted and unprocessed urine collected from symptomatic patients suspected of having urinary tract infections (UTIs). The microgel magnetic bead assay enables highly efficient conjugation and hydration of the immobilized DNAzymes, resulting in low limits-of-detection of 6 CFU/mL in buffer and 138 CFU/mL in unprocessed urine with high specificity against multiple urinary pathogens within a 1 hour assay time. The assay successfully identifies which patients are infected with E. coli as the causative organism for their UTI symptoms, indicating the clinical relevance of this assay.
Collapse
Affiliation(s)
- Richa Pandey
- Department of Engineering Physics, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
| | - Yang Lu
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
| | - Enas Osman
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
| | - Survanshu Saxena
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
| | - Zijie Zhang
- Department of Biochemistry and Biomedical Sciences, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
| | - Shuwen Qian
- Department of Biochemistry and Biomedical Sciences, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
| | - Angela Pollinzi
- Department of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L7, Canada
| | - Marek Smieja
- Department of Medicine, Pathology and Molecular Medicine, Research St. Joseph’s Hamilton, McMaster University, Hamilton, Ontario L8S 4L8, Canada
| | - Yingfu Li
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
- Department of Biochemistry and Biomedical Sciences, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
| | - Leyla Soleymani
- Department of Engineering Physics, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
| | - Todd Hoare
- Department of Engineering Physics, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
- Department of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L7, Canada
| |
Collapse
|
61
|
Zamani M, Yang V, Maziashvili L, Fan G, Klapperich CM, Furst AL. Surface Requirements for Optimal Biosensing with Disposable Gold Electrodes. ACS MEASUREMENT SCIENCE AU 2022; 2:91-95. [PMID: 35479101 PMCID: PMC9026247 DOI: 10.1021/acsmeasuresciau.1c00042] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Revised: 11/06/2021] [Accepted: 11/08/2021] [Indexed: 05/05/2023]
Abstract
Electrochemical biosensors are promising technologies for detection and monitoring in low-resource settings due to their potential for easy use and low-cost instrumentation. Disposable gold screen-printed electrodes (SPEs) are popular substrates for these biosensors, but necessary dopants in the ink used for their production can interfere with biosensor function and contribute to the heterogeneity of these electrodes. We recently reported an alternative disposable gold electrode made from gold leaf generated using low-cost, equipment-free fabrication. We have directly compared the surface topology, biorecognition element deposition, and functional performance of three disposable gold electrodes: our gold leaf electrodes and two commercial SPEs. Our leaf electrodes significantly outperformed the SPEs for reproducible and effective biosensing in a DNase I assay and are nearly an order of magnitude less expensive than the SPEs. Therefore, these electrodes are promising for further development as point-of-care diagnostics, especially in low-resource settings.
Collapse
Affiliation(s)
- Marjon Zamani
- Department
of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, Massachusetts 02139, United States
| | - Victoria Yang
- Department
of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, Massachusetts 02139, United States
| | - Lizi Maziashvili
- Department
of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, Massachusetts 02139, United States
| | - Gang Fan
- Department
of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, Massachusetts 02139, United States
| | - Catherine M. Klapperich
- Department
of Biomedical Engineering, Boston University, Boston, Massachusetts 02215, United States
| | - Ariel L. Furst
- Department
of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, Massachusetts 02139, United States
- Center
for Environmental Health Sciences, Massachusetts
Institute of Technology, Cambridge, Massachusetts 02139, United States
| |
Collapse
|
62
|
Thompson CJ, Kienle DF, Schwartz DK. Enhanced Facilitated Diffusion of Membrane-Associating Proteins under Symmetric Confinement. J Phys Chem Lett 2022; 13:2901-2907. [PMID: 35333540 DOI: 10.1021/acs.jpclett.2c00227] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The facilitated surface diffusion of transiently adsorbing molecules in a planar confined microenvironment (i.e., slit-like confinement) is highly relevant to biological phenomena, such as extracellular signaling, as well as numerous biotechnology systems. Here, we studied the surface diffusion of individual proteins confined between two symmetric lipid bilayer membranes, under a continuum of confinement heights, using single-molecule tracking and convex lens-induced confinement as well as hybrid, kinetic Monte Carlo simulations of a generalized continuous time random walk process. Surface diffusion was observed to vary non-monotonically with confinement height, exhibiting a maximum at a height of ∼750 nm, where diffusion was nearly 40% greater than that for a semi-infinite system. This demonstrated that planar confinement can, in fact, increase surface diffusion, qualitatively validating previous theoretical predictions. Simulations reproduced the experimental results and suggested that confinement enhancement of surface diffusion for symmetric systems is limited to cases where the adsorbate exhibits weak surface sticking.
Collapse
Affiliation(s)
- Connor J Thompson
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, Colorado 80309, United States
| | - Daniel F Kienle
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, Colorado 80309, United States
| | - Daniel K Schwartz
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, Colorado 80309, United States
| |
Collapse
|
63
|
Gowda HN, Kido H, Wu X, Shoval O, Lee A, Lorenzana A, Madou M, Hoffmann M, Jiang SC. Development of a proof-of-concept microfluidic portable pathogen analysis system for water quality monitoring. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 813:152556. [PMID: 34952082 PMCID: PMC8837627 DOI: 10.1016/j.scitotenv.2021.152556] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 12/15/2021] [Accepted: 12/16/2021] [Indexed: 05/03/2023]
Abstract
Waterborne diseases cause millions of deaths worldwide, especially in developing communities. The monitoring and rapid detection of microbial pathogens in water is critical for public health protection. This study reports the development of a proof-of-concept portable pathogen analysis system (PPAS) that can detect bacteria in water with the potential application in a point-of-sample collection setting. A centrifugal microfluidic platform is adopted to integrate bacterial cell lysis in water samples, nucleic acid extraction, and reagent mixing with a droplet digital loop mediated isothermal amplification assay for bacteria quantification onto a single centrifugal disc (CD). Coupled with a portable "CD Driver" capable of automating the assay steps, the CD functions as a single step bacterial detection "lab" without the need to transfer samples from vial-to-vial as in a traditional laboratory. The prototype system can detect Enterococcus faecalis, a common fecal indicator bacterium, in water samples with a single touch of a start button within 1 h and having total hands-on-time being less than 5 min. An add-on bacterial concentration cup prefilled with absorbent polymer beads was designed to integrate with the pathogen CD to improve the downstream quantification sensitivity. All reagents and amplified products are contained within the single-use disc, reducing the opportunity of cross contamination of other samples by the amplification products. This proof-of-concept PPAS lays the foundation for field testing devices in areas needing more accessible water quality monitoring tools and are at higher risk for being exposed to contaminated waters.
Collapse
Affiliation(s)
- Hamsa N Gowda
- Samueli School of Engineering, University of California, Irvine, Irvine, CA 92617, USA
| | - Horacio Kido
- Samueli School of Engineering, University of California, Irvine, Irvine, CA 92617, USA
| | - Xunyi Wu
- Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA 91125, USA
| | - Oren Shoval
- Samueli School of Engineering, University of California, Irvine, Irvine, CA 92617, USA
| | - Adrienne Lee
- Samueli School of Engineering, University of California, Irvine, Irvine, CA 92617, USA
| | - Albert Lorenzana
- Samueli School of Engineering, University of California, Irvine, Irvine, CA 92617, USA
| | - Marc Madou
- Samueli School of Engineering, University of California, Irvine, Irvine, CA 92617, USA
| | - Michael Hoffmann
- Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA 91125, USA
| | - Sunny C Jiang
- Samueli School of Engineering, University of California, Irvine, Irvine, CA 92617, USA.
| |
Collapse
|
64
|
Huang J, Chen G, Sun Y, Huang Y, Liu L, Xu H. A Dual-Recognition Strategy for Staphylococcus aureus Detection Using Teicoplanin-Modified Magnetic Nanoparticles and IgG-Functionalized Quantum Dots. FOOD ANAL METHOD 2022. [DOI: 10.1007/s12161-022-02256-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
65
|
Nagy B, Campana M, Khaydukov YN, Ederth T. Structure and pH-Induced Swelling of Polymer Films Prepared from Sequentially Grafted Polyelectrolytes. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022; 38:1725-1737. [PMID: 35081310 PMCID: PMC8830213 DOI: 10.1021/acs.langmuir.1c02784] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 01/13/2022] [Indexed: 05/16/2023]
Abstract
We have prepared a series of ampholytic polymer films, using a self-initiated photografting and photopolymerization (SI-PGP) method to sequentially polymerize first anionic (deuterated methacrylic acid (dMAA)) and thereafter cationic (2-aminoethyl methacrylate (AEMA)) monomers to investigate the SI-PGP grafting process. Dry films were investigated by ellipsometry, X-ray, and neutron reflectometry, and their swelling was followed over a pH range from 4.5 to 10.5 with spectroscopic ellipsometry. The deuterated monomer allows us to separate the distributions of the two components by neutron reflectometry. Growth of both polymers proceeds via grafting of solution-polymerized fragments to the surface, and also the second layer is primarily grafted to the substrate and not as a continuation of the existing chains. The polymer films are stratified, with one layer of near 1:1 composition and the other layer enriched in one component and located either above or below the former layer. The ellipsometry results show swelling transitions at low and high pH but with no systematic variation in the pH values where these transitions occur. The results suggest that grafting density in SI-PGP-prepared homopolymers could be increased via repeated polymerization steps, but that this process does not necessarily increase the average chain length.
Collapse
Affiliation(s)
- Béla Nagy
- Division
of Biophysics and Bioengineering, Department of Physics, Chemistry
and Biology, Linköping University, SE-581 83 Linköping, Sweden
| | - Mario Campana
- ISIS
Facility, Rutherford Appleton Laboratory,
STFC, Chilton, Didcot, Oxon OX11
0QX, U.K.
| | - Yury N. Khaydukov
- Max-Planck-Institut
für Festkörperforschung, Heisenbergstraße 1, D-70569 Stuttgart, Germany
- Max
Planck Society Outstation at the Heinz Maier-Leibnitz Zentrum (MLZ), D-85748 Garching, Germany
| | - Thomas Ederth
- Division
of Biophysics and Bioengineering, Department of Physics, Chemistry
and Biology, Linköping University, SE-581 83 Linköping, Sweden
| |
Collapse
|
66
|
Lasserre P, Balansethupathy B, Vezza VJ, Butterworth A, Macdonald A, Blair EO, McAteer L, Hannah S, Ward AC, Hoskisson PA, Longmuir A, Setford S, Farmer ECW, Murphy ME, Flynn H, Corrigan DK. SARS-CoV-2 Aptasensors Based on Electrochemical Impedance Spectroscopy and Low-Cost Gold Electrode Substrates. Anal Chem 2022; 94:2126-2133. [PMID: 35043638 PMCID: PMC8790822 DOI: 10.1021/acs.analchem.1c04456] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 12/24/2021] [Indexed: 02/07/2023]
Abstract
SARS-CoV-2 diagnostic practices broadly involve either quantitative polymerase chain reaction (qPCR)-based nucleic amplification of viral sequences or antigen-based tests such as lateral flow assays (LFAs). Reverse transcriptase-qPCR can detect viral RNA and is the gold standard for sensitivity. However, the technique is time-consuming and requires expensive laboratory infrastructure and trained staff. LFAs are lower in cost and near real time, and because they are antigen-based, they have the potential to provide a more accurate indication of a disease state. However, LFAs are reported to have low real-world sensitivity and in most cases are only qualitative. Here, an antigen-based electrochemical aptamer sensor is presented, which has the potential to address some of these shortfalls. An aptamer, raised to the SARS-CoV-2 spike protein, was immobilized on a low-cost gold-coated polyester substrate adapted from the blood glucose testing industry. Clinically relevant detection levels for SARS-CoV-2 are achieved in a simple, label-free measurement format using sample incubation times as short as 15 min on nasopharyngeal swab samples. This assay can readily be optimized for mass manufacture and is compatible with a low-cost meter.
Collapse
Affiliation(s)
- Perrine Lasserre
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| | | | - Vincent J. Vezza
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| | - Adrian Butterworth
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| | - Alexander Macdonald
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| | - Ewen O. Blair
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| | - Liam McAteer
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| | - Stuart Hannah
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| | - Andrew C. Ward
- Department
of Civil and Environmental Engineering, University of Strathclyde, 75 Montrose Street, Glasgow G1 1XJ, U.K.
| | - Paul A. Hoskisson
- Strathclyde
Institute of Pharmacy and Biomedical Sciences (SIPBS), University of Strathclyde, 161 Cathedral Street, Glasgow G4 0RE, U.K.
| | - Alistair Longmuir
- LifeScan
Scotland Ltd, Beechwood Park North, Inverness IV2 3ED, U.K.
| | - Steven Setford
- LifeScan
Scotland Ltd, Beechwood Park North, Inverness IV2 3ED, U.K.
| | - Eoghan C. W. Farmer
- NHS GGC,
Department of Microbiology, Glasgow Royal
Infirmary, NEW Lister Building, Glasgow G31 2ER, United Kingdom
| | - Michael E. Murphy
- NHS GGC,
Department of Microbiology, Glasgow Royal
Infirmary, NEW Lister Building, Glasgow G31 2ER, United Kingdom
- School
of Medicine, Dentistry & Nursing, College of Medical Veterinary
& Life Sciences, University of Glasgow, Glasgow G12 8QQ, United Kingdom
| | - Harriet Flynn
- Aptamer
Group, Suite 2.78−2.91,
Bio Centre, Innovation Way, Heslington, York YO10 5NY, U.K.
- Department
of Pure and Applied Chemistry, University
of Strathclyde, 295 Cathedral
Street, Glasgow, G1 1XL, United Kingdom
| | - Damion K. Corrigan
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| |
Collapse
|
67
|
Lorenzen AL, dos Santos AM, dos Santos LP, da Silva Pinto L, Conceição FR, Wolfart F. PEDOT-AuNPs-based impedimetric immunosensor for the detection of SARS-CoV-2 antibodies. Electrochim Acta 2022; 404:139757. [PMID: 34955549 PMCID: PMC8684030 DOI: 10.1016/j.electacta.2021.139757] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 12/11/2021] [Accepted: 12/16/2021] [Indexed: 12/16/2022]
Abstract
Electrochemical sensors and biosensors are useful techniques for fast, inexpensive, sensitive, and easy detection of innumerous specimen. In face of COVID-19 pandemic, it became evident the necessity of a rapid and accurate diagnostic test, so the impedimetric immunosensor approach can be a good alternative to replace the conventional tests due to the specific antibody-antigen binding interaction and the fast response in comparison to traditional methods. In this work, a modified electrode with electrosynthesized PEDOT and gold nanoparticles followed by the immobilization of truncated nucleoprotein (N aa160-406aa) was used for a fast and reliable detection of antibodies against COVID-19 in human serum sample. The method consists in analyzing the charge-transfer resistance (RCT) variation before and after the modified electrode comes into contact with the positive and negative serum sample for COVID-19, using [Fe(CN)6]3-/4- as a probe. The results show a linear and selective response for serum samples diluted in a range of 2.5 × 103 to 20 × 103. Also, the electrode material was fully characterized by Raman spectroscopy, transmission electron microscopy and scanning electron microscopy coupled with EDS, indicating that the gold nanoparticles were well distributed around the polymer matrix and the presence of the biological sample was confirmed by EDS analysis. EIS measurements allowed to differentiate the negative and positive samples by the difference in the RCT magnitude, proving that the material developed here has potential properties to be applied in impedimetric immunosensors for the detection of SARS-CoV-2 antibodies in about 30 min.
Collapse
Affiliation(s)
- Ana Luiza Lorenzen
- Instituto Federal de Educação, Ciência e Tecnologia Farroupilha – Campus São Borja, Rua Otaviano Castilho Mendes, 355, Betim, São Borja, RS CEP 97670-000, Brazil
| | - Ariane Moraes dos Santos
- Instituto Federal de Educação, Ciência e Tecnologia Farroupilha – Campus São Borja, Rua Otaviano Castilho Mendes, 355, Betim, São Borja, RS CEP 97670-000, Brazil
| | - Luâni Poll dos Santos
- Instituto Federal de Educação, Ciência e Tecnologia Farroupilha – Campus São Borja, Rua Otaviano Castilho Mendes, 355, Betim, São Borja, RS CEP 97670-000, Brazil
| | - Luciano da Silva Pinto
- Universidade Federal de Pelotas, Centro de Desenvolvimento Tecnológico, Núcleo de Biotecnologia – Campus Capão do Leão, S/N, Capão do Leão, RS CEP 96160-000, Brazil
| | - Fabricio Rochedo Conceição
- Universidade Federal de Pelotas, Centro de Desenvolvimento Tecnológico, Núcleo de Biotecnologia – Campus Capão do Leão, S/N, Capão do Leão, RS CEP 96160-000, Brazil
| | - Franciele Wolfart
- Instituto Federal de Educação, Ciência e Tecnologia Farroupilha – Campus São Borja, Rua Otaviano Castilho Mendes, 355, Betim, São Borja, RS CEP 97670-000, Brazil,Corresponding author
| |
Collapse
|
68
|
Hou Z, Jin Y, Li Y, Fan H, Xiao C, Li Q, Zhang Y. Immobilization of peroxisome proliferator-activated receptor gamma and the application in screening modulators of the receptor from herbal medicine. J Chromatogr B Analyt Technol Biomed Life Sci 2022; 1190:123098. [PMID: 35026651 DOI: 10.1016/j.jchromb.2022.123098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 12/28/2021] [Accepted: 01/03/2022] [Indexed: 10/19/2022]
Abstract
Screening and identification of potential compounds from herbal medicine is a prevailing way to find a lead for the development of innovative drugs. This promotes the development of new methods that are feasible in complex matrices. Here, we described a one-step reversible methodology to immobilize nuclear peroxisome proliferator-activated receptor gamma (PPARγ) onto amino microsphere coated with a DNA strand specifically binding to the receptor. The specific interaction allowed us to achieve the immobilization of PPARγ by mixing the DNA modified microspheres with E. coli lysates expressing the receptor. Characterization of the immobilized receptor was carried out by morphology and binding specificity analysis. Feasibility of immobilized PPARγ in the drug-receptor interaction analysis was performed by an injection amount-dependent method. Besides, immobilized PPARγ was also applied in screening modulators of the receptor from Coptidis Rhizoma extract. The binding of the screened compounds to PPARγ was examined by time-resolved fluorescence resonance energy transfer assay. The results showed that immobilized PPARγ was stable for thirty days with a high-specificity of ligand recognition at the subtype receptor level. Berberine and palmatine were the bioactive compounds of Coptidis Rhizoma specifically binding to PPARγ. The two compounds exhibited half maximal inhibitory concentrations of 4.11 and 2.98 μM during their binding to the receptor. We concluded that the current method is possible to become a common strategy for the immobilization of nuclear receptors, and the immobilized receptor is a high throughput method for recognizing and separating the receptor modulators from complex matrices including herbal medicine.
Collapse
Affiliation(s)
- Zhaoling Hou
- Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, Ministry of Life Sciences and Medicine, Northwest University, Xi'an 710069, China
| | - Yan Jin
- Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, Ministry of Life Sciences and Medicine, Northwest University, Xi'an 710069, China
| | - Yuxin Li
- Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, Ministry of Life Sciences and Medicine, Northwest University, Xi'an 710069, China
| | - Hushuai Fan
- Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, Ministry of Life Sciences and Medicine, Northwest University, Xi'an 710069, China
| | - Chaoni Xiao
- Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, Ministry of Life Sciences and Medicine, Northwest University, Xi'an 710069, China
| | - Qian Li
- Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, Ministry of Life Sciences and Medicine, Northwest University, Xi'an 710069, China
| | - Yajun Zhang
- Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, Ministry of Life Sciences and Medicine, Northwest University, Xi'an 710069, China.
| |
Collapse
|
69
|
Wei Y, Zhou W, Wu Y, Zhu H. High Sensitivity Label-Free Quantitative Method for Detecting Tumor Biomarkers in Human Serum by Optical Microfiber Couplers. ACS Sens 2021; 6:4304-4314. [PMID: 34806360 DOI: 10.1021/acssensors.1c01031] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Label-free optical fiber immunosensors have attracted widespread attention in recent decades due to their high sensitivity. However, nonspecific adsorption in serum has remained a critical bottleneck in existing label-free fiber optic biosensors, which hinders their widespread use in diagnostics. In addition, individual differences in clinical human serum (HS) negatively impact biosensing results. In this work, the modified serum preadsorption strategy was applied to reduce nonspecific adsorption by forming a saturated antifouling interface on an optical microfiber coupler (OMC). Furthermore, to reduce the effect of the differences between individual HS samples, we proposed a new method where Sigma HS was used as a wavelength shift reference due to being close to clinical serum compared to other serums. Sigma HS was used first to reduce the differences in immune sensors before performing a clinical sample test in which quantitative detection was achieved based on the independent calibration of several sensors with wide dynamic ranges via dissociation processes. The individual differences in 25% HS were corrected by 30% Sigma HS. As a proof of concept, the label-free OMC immune sensor demonstrates good sensitivity and specificity for the detection of carcinoembryonic antigen (CEA) in 25% Sigma HS at different concentrations. The detection limit of CEA reached as low as 34.6 fg/mL (0.475 fM). Additionally, label-free quantitative detection of CEA using this OMC immune sensor was verified experimentally according to the calibration line, and the results agree well with clinical examination detection. To our knowledge, it is the first study to employ an OMC immune sensor in point-of-care label-free quantitative detection for clinical HS.
Collapse
Affiliation(s)
- Youlian Wei
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, PR China
- University of Chinese Academy of Sciences, Beijing 100039, PR China
| | - Wenchao Zhou
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, PR China
| | - Yihui Wu
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, PR China
| | - Hongquan Zhu
- The Second Hospital of Jilin University, Changchun 130041, PR China
| |
Collapse
|
70
|
Forinová M, Pilipenco A, Víšová I, Lynn NS, Dostálek J, Mašková H, Hönig V, Palus M, Selinger M, Kočová P, Dyčka F, Štěrba J, Houska M, Vrabcová M, Horák P, Anthi J, Tung CP, Yu CM, Chen CY, Huang YC, Tsai PH, Lin SY, Hsu HJ, Yang AS, Dejneka A, Vaisocherová-Lísalová H. Functionalized Terpolymer-Brush-Based Biointerface with Improved Antifouling Properties for Ultra-Sensitive Direct Detection of Virus in Crude Clinical Samples. ACS APPLIED MATERIALS & INTERFACES 2021; 13:60612-60624. [PMID: 34902239 DOI: 10.1021/acsami.1c16930] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
New analytical techniques that overcome major drawbacks of current routinely used viral infection diagnosis methods, i.e., the long analysis time and laboriousness of real-time reverse-transcription polymerase chain reaction (qRT-PCR) and the insufficient sensitivity of "antigen tests", are urgently needed in the context of SARS-CoV-2 and other highly contagious viruses. Here, we report on an antifouling terpolymer-brush biointerface that enables the rapid and sensitive detection of SARS-CoV-2 in untreated clinical samples. The developed biointerface carries a tailored composition of zwitterionic and non-ionic moieties and allows for the significant improvement of antifouling capabilities when postmodified with biorecognition elements and exposed to complex media. When deployed on a surface of piezoelectric sensor and postmodified with human-cell-expressed antibodies specific to the nucleocapsid (N) protein of SARS-CoV-2, it made possible the quantitative analysis of untreated samples by a direct detection assay format without the need of additional amplification steps. Natively occurring N-protein-vRNA complexes, usually disrupted during the sample pre-treatment steps, were detected in the untreated clinical samples. This biosensor design improved the bioassay sensitivity to a clinically relevant limit of detection of 1.3 × 104 PFU/mL within a detection time of only 20 min. The high specificity toward N-protein-vRNA complexes was validated both by mass spectrometry and qRT-PCR. The performance characteristics were confirmed by qRT-PCR through a comparative study using a set of clinical nasopharyngeal swab samples. We further demonstrate the extraordinary fouling resistance of this biointerface through exposure to other commonly used crude biological samples (including blood plasma, oropharyngeal, stool, and nasopharyngeal swabs), measured via both the surface plasmon resonance and piezoelectric measurements, which highlights the potential to serve as a generic platform for a wide range of biosensing applications.
Collapse
Affiliation(s)
- Michala Forinová
- Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21 Prague, Czech Republic
| | - Alina Pilipenco
- Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21 Prague, Czech Republic
| | - Ivana Víšová
- Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21 Prague, Czech Republic
| | - N Scott Lynn
- Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21 Prague, Czech Republic
| | - Jakub Dostálek
- Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21 Prague, Czech Republic
- Austrian Institute of Technology GmbH, Konrad-Lorenz-Strasse 24, 3430 Tulln, Austria
| | - Hana Mašková
- Faculty of Science, University of South Bohemia, Branišovská 31a, 370 05 České Budějovice, Czech Republic
| | - Václav Hönig
- Institute of Parasitology, Biology Centre CAS, Branišovská 31, 370 05 České Budějovice, Czech Republic
- Veterinary Research Institute, Hudcova 70, 621 00 Brno, Czech Republic
| | - Martin Palus
- Institute of Parasitology, Biology Centre CAS, Branišovská 31, 370 05 České Budějovice, Czech Republic
- Veterinary Research Institute, Hudcova 70, 621 00 Brno, Czech Republic
| | - Martin Selinger
- Faculty of Science, University of South Bohemia, Branišovská 31a, 370 05 České Budějovice, Czech Republic
- Institute of Parasitology, Biology Centre CAS, Branišovská 31, 370 05 České Budějovice, Czech Republic
| | - Pavlína Kočová
- Faculty of Science, University of South Bohemia, Branišovská 31a, 370 05 České Budějovice, Czech Republic
| | - Filip Dyčka
- Faculty of Science, University of South Bohemia, Branišovská 31a, 370 05 České Budějovice, Czech Republic
| | - Jan Štěrba
- Faculty of Science, University of South Bohemia, Branišovská 31a, 370 05 České Budějovice, Czech Republic
| | - Milan Houska
- Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21 Prague, Czech Republic
| | - Markéta Vrabcová
- Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21 Prague, Czech Republic
| | - Petr Horák
- Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21 Prague, Czech Republic
| | - Judita Anthi
- Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21 Prague, Czech Republic
| | - Chao-Ping Tung
- Genomics Research Center, Academia Sinica, 128 Academia Rd., Sec.2, Nankang Dist., Taipei 115, Taiwan
| | - Chung-Ming Yu
- Genomics Research Center, Academia Sinica, 128 Academia Rd., Sec.2, Nankang Dist., Taipei 115, Taiwan
| | - Chi-Yung Chen
- Genomics Research Center, Academia Sinica, 128 Academia Rd., Sec.2, Nankang Dist., Taipei 115, Taiwan
| | - Yu-Chuan Huang
- Genomics Research Center, Academia Sinica, 128 Academia Rd., Sec.2, Nankang Dist., Taipei 115, Taiwan
| | - Pei-Hsun Tsai
- Genomics Research Center, Academia Sinica, 128 Academia Rd., Sec.2, Nankang Dist., Taipei 115, Taiwan
| | - Szu-Yu Lin
- Genomics Research Center, Academia Sinica, 128 Academia Rd., Sec.2, Nankang Dist., Taipei 115, Taiwan
| | - Hung-Ju Hsu
- Genomics Research Center, Academia Sinica, 128 Academia Rd., Sec.2, Nankang Dist., Taipei 115, Taiwan
| | - An-Suei Yang
- Genomics Research Center, Academia Sinica, 128 Academia Rd., Sec.2, Nankang Dist., Taipei 115, Taiwan
| | - Alexandr Dejneka
- Institute of Physics of the Czech Academy of Sciences, Na Slovance 2, 182 21 Prague, Czech Republic
| | | |
Collapse
|
71
|
Core-Shell Imprinted Particles for Adenovirus Binding. MATERIALS 2021; 14:ma14247692. [PMID: 34947287 PMCID: PMC8703578 DOI: 10.3390/ma14247692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/22/2021] [Revised: 11/28/2021] [Accepted: 12/10/2021] [Indexed: 11/17/2022]
Abstract
Virus-imprinted polymers were synthesized via surface imprinting strategies to produce core-shell imprinted particles selective for human adenovirus type 5. High binding affinity of the target virus towards the resulting imprinted layer was confirmed and unspecific binding was reduced in presence of blocking agents, i.e., via bovine serum albumin and skim milk in combination with Tween 20. In addition, the imprinted materials were applied for adenovirus extraction from cell culture supernatants. High levels of virus binding with negligible binding of matrix proteins confirmed the suitability of these materials for binding and extraction of the target virus from complex matrices.
Collapse
|
72
|
Wang Y, Zhang B, Dodiuk H, Kenig S, Barry C, Ratto J, Mead J, Jia Z, Turkoglu S, Zhang J. Effect of Protein Adsorption on Air Plastron Behavior of a Superhydrophobic Surface. ACS APPLIED MATERIALS & INTERFACES 2021; 13:58096-58103. [PMID: 34813281 DOI: 10.1021/acsami.1c15981] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Protein fouling on critical biointerfaces causes significant public health and clinical ramifications. Multiple strategies, including superhydrophobic (SHP) surfaces and coatings, have been explored to mitigate protein adsorption on solid surfaces. SHP materials with underwater air plastron (AP) layers hold great promise by physically reducing the contact area between a substrate and protein molecules. However, sustaining AP stability or lifetime is crucial in determining the durability and long-term applications of SHP materials. This work investigated the effect of protein on the AP stability using model SHP substrates, which were prepared from a mixture of silica nanoparticles and epoxy. The AP stability was determined using a submersion test with real-time visualization. The results showed that AP stability was significantly weakened by protein solutions compared to water, which could be attributed to the surface tension of protein solutions and protein adsorption on SHP substrates. The results were further examined to reveal the correlation between protein fouling and accelerated AP dissipation on SHP materials by confocal fluorescent imaging, surface energy measurement, and surface robustness modeling of the Cassie-Baxter to Wenzel transition. The study reveals fundamental protein adsorption mechanisms on SHP materials, which could guide future SHP material design to better mitigate protein fouling on critical biointerfaces.
Collapse
Affiliation(s)
- Yujie Wang
- Department of Plastics Engineering, University of Massachusetts, Lowell, Massachusetts 01854, United States
- Biomedical Engineering & Biotechnology Program, University of Massachusetts, Lowell, Massachusetts 01854, United States
| | - Boce Zhang
- Department of Food Science and Human Nutrition, University of Florida, Gainesville, Florida 32611, United States
| | - Hanna Dodiuk
- Department of Plastics Engineering, University of Massachusetts, Lowell, Massachusetts 01854, United States
- Polymer Materials Engineering Department, The Pernick Faculty of Engineering, Shenkar College of Engineering Design and Art, Ramat Gan 5211401, Israel
| | - Shmuel Kenig
- Department of Plastics Engineering, University of Massachusetts, Lowell, Massachusetts 01854, United States
- Polymer Materials Engineering Department, The Pernick Faculty of Engineering, Shenkar College of Engineering Design and Art, Ramat Gan 5211401, Israel
| | - Carol Barry
- Department of Plastics Engineering, University of Massachusetts, Lowell, Massachusetts 01854, United States
| | - JoAnn Ratto
- The U.S. Army, Combat Capabilities Development Command - Soldier Center (DEVCOM Soldier Center), Natick, Massachusetts 01760, United States
| | - Joey Mead
- Department of Plastics Engineering, University of Massachusetts, Lowell, Massachusetts 01854, United States
| | - Zhen Jia
- Department of Food Science and Human Nutrition, University of Florida, Gainesville, Florida 32611, United States
| | - Sevil Turkoglu
- Department of Plastics Engineering, University of Massachusetts, Lowell, Massachusetts 01854, United States
| | - Jinde Zhang
- Department of Plastics Engineering, University of Massachusetts, Lowell, Massachusetts 01854, United States
| |
Collapse
|
73
|
Hernandez AL, Pujari SP, Laguna MF, Santamaría B, Zuilhof H, Holgado M. Efficient Chemical Surface Modification Protocol on SiO 2 Transducers Applied to MMP9 Biosensing. SENSORS 2021; 21:s21238156. [PMID: 34884157 PMCID: PMC8662398 DOI: 10.3390/s21238156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 12/02/2021] [Accepted: 12/04/2021] [Indexed: 12/01/2022]
Abstract
The bioreceptor immobilization process (biofunctionalization) turns to be one of the bottlenecks when developing a competent and high sensitivity label-free biosensor. Classical approaches seem to be effective but not efficient. Although biosensing capacities are shown in many cases, the performance of the biosensor is truncated by the inefficacious biofunctionalization protocol and the lack of reproducibility. In this work, we describe a unique biofunctionalization protocol based on chemical surface modification through silane chemistry on SiO2 optical sensing transducers. Even though silane chemistry is commonly used for sensing applications, here we present a different mode of operation, applying an unusual silane compound used for this purpose (3-Ethoxydimethylsilyl)propylamine, APDMS, able to create ordered monolayers, and minimizing fouling events. To endorse this protocol as a feasible method for biofunctionalization, we performed multiple surface characterization techniques after all the process steps: Contact angle (CA), X-ray photoelectron spectroscopy (XPS), ellipsometry, and fluorescence microscopy. Finally, to evidence the outputs from the SiO2 surface characterization, we used those SiO2 surfaces as optical transducers for the label-free biosensing of matrix metalloproteinase 9 (MMP9). We found and demonstrated that the originally designed protocol is reproducible, stable, and suitable for SiO2-based optical sensing transducers.
Collapse
Affiliation(s)
- Ana L. Hernandez
- Centre for Biomedical Technology, Universidad Politécnica de Madrid, Campus de Montegancedo, Pozuelo de Alarcon, 28223 Madrid, Spain; (M.F.L.); (B.S.); (M.H.)
- Correspondence: ; Tel.: +34-609-0020134
| | - Sidharam P. Pujari
- Laboratory of Organic Chemistry, Wageningen University & Research, Stippeneng 4, WE 6708 Wageningen, The Netherlands; (S.P.P.); (H.Z.)
| | - María F. Laguna
- Centre for Biomedical Technology, Universidad Politécnica de Madrid, Campus de Montegancedo, Pozuelo de Alarcon, 28223 Madrid, Spain; (M.F.L.); (B.S.); (M.H.)
- Department of Applied Physics, Escuela Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/Jose Gutierrez Abascal, 28006 Madrid, Spain
| | - Beatriz Santamaría
- Centre for Biomedical Technology, Universidad Politécnica de Madrid, Campus de Montegancedo, Pozuelo de Alarcon, 28223 Madrid, Spain; (M.F.L.); (B.S.); (M.H.)
- Department of Chemical, Mechanical and Industrial Design Engineering, ETS de Ingeniería y Diseño Industrial, Universidad Politécnica de Madrid, Ronda de Valencia 3, 28012 Madrid, Spain
| | - Han Zuilhof
- Laboratory of Organic Chemistry, Wageningen University & Research, Stippeneng 4, WE 6708 Wageningen, The Netherlands; (S.P.P.); (H.Z.)
- Institute for Molecular Design and Synthesis, School of Pharmaceutical Science & Technology, Tianjin University, 92 Weijin Road Nankai District, Tianjin 300072, China
- Department of Chemical and Materials Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Miguel Holgado
- Centre for Biomedical Technology, Universidad Politécnica de Madrid, Campus de Montegancedo, Pozuelo de Alarcon, 28223 Madrid, Spain; (M.F.L.); (B.S.); (M.H.)
- Department of Applied Physics, Escuela Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/Jose Gutierrez Abascal, 28006 Madrid, Spain
| |
Collapse
|
74
|
Rashid S, Ward-Bond J, Krupin O, Berini P. Non-specific adsorption of protein to microfluidic materials. Colloids Surf B Biointerfaces 2021; 208:112138. [DOI: 10.1016/j.colsurfb.2021.112138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 09/22/2021] [Accepted: 09/23/2021] [Indexed: 11/28/2022]
|
75
|
Covalent attachment of three derivatives of pegylated RGD peptides on the NH2-terminated silicon surfaces: Impact on fibroblast cell behavior. BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES 2021; 1863:183770. [PMID: 34517002 DOI: 10.1016/j.bbamem.2021.183770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2021] [Revised: 08/30/2021] [Accepted: 09/01/2021] [Indexed: 11/20/2022]
Abstract
This paper describes a simple strategy for covalent immobilization of the NHS-PEG-RGD peptide with the three different PEG lengths (8, 13, and 22) onto the amine-terminated monolayers with the subsequent investigation of fibroblast cellular response to the three derivatives of pegylated RGD peptides-modified substrates. First, acetamide-terminated monolayers were prepared on the hydride terminated silicon surface to protect NH2-terminated monolayers. This was followed by the removal of the protective groups, and the reaction of NHS-PEG8-RGD, NHS-PEG13-RGD and NHS-PEG22-RGD peptides with the NH2-terminated monolayers while reducing nonspecific protein adsorption. Analysis of X-ray photoelectron spectroscopy (XPS), Fourier Transform Infrared (ATR-FTIR) spectroscopy, and Ellipsometry measurements demonstrated that PEG13-RGD peptide forms relatively a more homogenous, thicker and stable structure compared with those of PEG8-RGD and PEG22-RGD peptide. The quantitative and qualitative assessment of cell adhesion, spreading, and proliferation indicated that relatively further elongated fibroblast cells attached on the PEG13-RGD peptide relative to those on the PEG8-RGD and PEG22-RGD peptide. The results presented here may offer a developed strategy based on the length of the spacer to regulate cellular behavior on the surface substrates.
Collapse
|
76
|
Usha SP, Manoharan H, Deshmukh R, Álvarez-Diduk R, Calucho E, Sai VVR, Merkoçi A. Attomolar analyte sensing techniques (AttoSens): a review on a decade of progress on chemical and biosensing nanoplatforms. Chem Soc Rev 2021; 50:13012-13089. [PMID: 34673860 DOI: 10.1039/d1cs00137j] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Detecting the ultra-low abundance of analytes in real-life samples, such as biological fluids, water, soil, and food, requires the design and development of high-performance biosensing modalities. The breakthrough efforts from the scientific community have led to the realization of sensing technologies that measure the analyte's ultra-trace level, with relevant sensitivity, selectivity, response time, and sampling efficiency, referred to as Attomolar Analyte Sensing Techniques (AttoSens) in this review. In an AttoSens platform, 1 aM detection corresponds to the quantification of 60 target analyte molecules in 100 μL of sample volume. Herein, we review the approaches listed for various sensor probe design, and their sensing strategies that paved the way for the detection of attomolar (aM: 10-18 M) concentration of analytes. A summary of the technological advances made by the diverse AttoSens trends from the past decade is presented.
Collapse
Affiliation(s)
- Sruthi Prasood Usha
- Biomedical Engineering, Department of Applied Mechanics, Indian Institute of Technology Madras (IITM), India.
| | - Hariharan Manoharan
- Biomedical Engineering, Department of Applied Mechanics, Indian Institute of Technology Madras (IITM), India.
| | - Rehan Deshmukh
- Biomedical Engineering, Department of Applied Mechanics, Indian Institute of Technology Madras (IITM), India.
| | - Ruslan Álvarez-Diduk
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), Campus UAB, Barcelona, Spain.
| | - Enric Calucho
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), Campus UAB, Barcelona, Spain.
| | - V V R Sai
- Biomedical Engineering, Department of Applied Mechanics, Indian Institute of Technology Madras (IITM), India.
| | - Arben Merkoçi
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), Campus UAB, Barcelona, Spain. .,ICREA, Institució Catalana de Recercai Estudis Avançats, Barcelona, Spain
| |
Collapse
|
77
|
Sharafeldin M, James T, Davis JJ. Open Circuit Potential as a Tool for the Assessment of Binding Kinetics and Reagentless Protein Quantitation. Anal Chem 2021; 93:14748-14754. [PMID: 34699180 DOI: 10.1021/acs.analchem.1c03292] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
A microfluidic open circuit potential label-free protein assay was developed for the reagentless quantification of C-reactive protein (CRP), a model protein target, and further utilized to assess target-receptor binding kinetics. Generated sensors have very high baseline stabilities (<1% change in 100 min) and high levels of selectivity in complex media. Real-time assays are fast (<20 min), of high sensitivity (1 ng/mL limit of detection for CRP in serum), and resolve kinetic and thermodynamic characteristics that correlate well with those resolved optically. The assay shows excellent correlation with an enzyme-linked immunosorbent assay analysis of patient samples. The methodology has value in potentially underpinning a low-cost, rapid, and sensitive single-step biomarker quantification.
Collapse
Affiliation(s)
- Mohamed Sharafeldin
- Department of Chemistry, University of Oxford, South Parks Road, Oxford OX1 3QZ, U.K
| | - Timothy James
- Department of Clinical Biochemistry, Oxford University Hospitals NHS Trust, Oxford OX3 9DU, U.K
| | - Jason J Davis
- Department of Chemistry, University of Oxford, South Parks Road, Oxford OX1 3QZ, U.K
| |
Collapse
|
78
|
Harijan M, Singh M. Zwitterionic polymers in drug delivery: A review. J Mol Recognit 2021; 35:e2944. [PMID: 34738272 DOI: 10.1002/jmr.2944] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Revised: 10/10/2021] [Accepted: 10/17/2021] [Indexed: 12/17/2022]
Abstract
Developments of novel drug delivery vehicles are sought-after to augment the therapeutic effectiveness of standard drugs. An urgency to design novel drug delivery vehicles that are sustainable, biocompatible, have minimized cytotoxicity, no immunogenicity, high stability, long circulation time, and are capable of averting recognition by the immune system is perceived. In this pursuit for an ideal candidate for drug delivery vehicles, zwitterionic materials have come up as fulfilling almost all these expectations. This comprehensive review is presenting the progress made by zwitterionic polymeric architectures as prospective sustainable drug delivery vehicles. Zwitterionic polymers with varied architecture such as appending protein conjugates, nanoparticles, surface coatings, liposomes, hydrogels, etc, used to fabricate drug delivery vehicles are reviewed here. A brief introduction of zwitterionic polymers and their application as reliable drug delivery vehicles, such as zwitterionic polymer-protein conjugates, zwitterionic polymer-based drug nanocarriers, and stimulus-responsive zwitterionic polymers are discussed in this discourse. The prospects shown by zwitterionic architecture suggest the tremendous potential for them in this domain. This critical review will encourage the researchers working in this area and boost the development and commercialization of such devices to benefit the healthcare fraternity.
Collapse
Affiliation(s)
- Manjeet Harijan
- Department of Chemistry, MMV, Banaras Hindu University, Varanasi, India
| | - Meenakshi Singh
- Department of Chemistry, MMV, Banaras Hindu University, Varanasi, India
| |
Collapse
|
79
|
Terracciano R, Carcamo-Bahena Y, Butler EB, Demarchi D, Grattoni A, Filgueira CS. Hyaluronate-Thiol Passivation Enhances Gold Nanoparticle Peritumoral Distribution When Administered Intratumorally in Lung Cancer. Biomedicines 2021; 9:1561. [PMID: 34829790 PMCID: PMC8615404 DOI: 10.3390/biomedicines9111561] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 10/21/2021] [Accepted: 10/23/2021] [Indexed: 12/13/2022] Open
Abstract
Biofouling is the unwanted adsorption of cells, proteins, or intracellular and extracellular biomolecules that can spontaneously occur on the surface of metal nanocomplexes. It represents a major issue in bioinorganic chemistry because it leads to the creation of a protein corona, which can destabilize a colloidal solution and result in undesired macrophage-driven clearance, consequently causing failed delivery of a targeted drug cargo. Hyaluronic acid (HA) is a bioactive, natural mucopolysaccharide with excellent antifouling properties, arising from its hydrophilic and polyanionic characteristics in physiological environments which prevent opsonization. In this study, hyaluronate-thiol (HA-SH) (MW 10 kDa) was used to surface-passivate gold nanoparticles (GNPs) synthesized using a citrate reduction method. HA functionalized GNP complexes (HA-GNPs) were characterized using absorption spectroscopy, scanning electron microscopy, zeta potential, and dynamic light scattering. GNP cellular uptake and potential dose-dependent cytotoxic effects due to treatment were evaluated in vitro in HeLa cells using inductively coupled plasma-optical emission spectrometry (ICP-OES) and trypan blue and MTT assays. Further, we quantified the in vivo biodistribution of intratumorally injected HA functionalized GNPs in Lewis Lung carcinoma (LLC) solid tumors grown on the flank of C57BL/6 mice and compared localization and retention with nascent particles. Our results reveal that HA-GNPs show overall greater peritumoral distribution (** p < 0.005, 3 days post-intratumoral injection) than citrate-GNPs with reduced biodistribution in off-target organs. This property represents an advantageous step forward in localized delivery of metal nano-complexes to the infiltrative region of a tumor, which may improve the application of nanomedicine in the diagnosis and treatment of cancer.
Collapse
Affiliation(s)
- Rossana Terracciano
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX 77030, USA; (R.T.); (Y.C.-B.); (A.G.)
- Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Torino, Italy;
| | - Yareli Carcamo-Bahena
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX 77030, USA; (R.T.); (Y.C.-B.); (A.G.)
| | - E. Brian Butler
- Department of Radiation Oncology, Houston Methodist Research Institute, Houston, TX 77030, USA;
| | - Danilo Demarchi
- Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Torino, Italy;
| | - Alessandro Grattoni
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX 77030, USA; (R.T.); (Y.C.-B.); (A.G.)
- Department of Radiation Oncology, Houston Methodist Research Institute, Houston, TX 77030, USA;
- Department of Surgery, Houston Methodist Research Institute, Houston, TX 77030, USA
| | - Carly S. Filgueira
- Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX 77030, USA; (R.T.); (Y.C.-B.); (A.G.)
- Department of Cardiovascular Surgery, Houston Methodist Research Institute, Houston, TX 77030, USA
| |
Collapse
|
80
|
Payne TD, Klawa SJ, Jian T, Kim S, Papanikolas MJ, Freeman R, Schultz ZD. Catching COVID: Engineering Peptide-Modified Surface-Enhanced Raman Spectroscopy Sensors for SARS-CoV-2. ACS Sens 2021; 6:3436-3444. [PMID: 34491043 PMCID: PMC8442610 DOI: 10.1021/acssensors.1c01344] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Accepted: 08/24/2021] [Indexed: 12/11/2022]
Abstract
COVID-19 remains an ongoing issue across the globe, highlighting the need for a rapid, selective, and accurate sensor for SARS-CoV-2 and its emerging variants. The chemical specificity and signal amplification of surface-enhanced Raman spectroscopy (SERS) could be advantageous for developing a quantitative assay for SARS-CoV-2 with improved speed and accuracy over current testing methods. Here, we have tackled the challenges associated with SERS detection of viruses. As viruses are large, multicomponent species, they can yield different SERS signals, but also other abundant biomolecules present in the sample can generate undesired signals. To improve selectivity in complex biological environments, we have employed peptides as capture probes for viral proteins and developed an angiotensin-converting enzyme 2 (ACE2) mimetic peptide-based SERS sensor for SARS-CoV-2. The unique vibrational signature of the spike protein bound to the peptide-modified surface is identified and used to construct a multivariate calibration model for quantification. The sensor demonstrates a 300 nM limit of detection and high selectivity in the presence of excess bovine serum albumin. This work provides the basis for designing a SERS-based assay for the detection of SARS-CoV-2 as well as engineering SERS biosensors for other viruses in the future.
Collapse
Affiliation(s)
- Taylor D. Payne
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, United States
| | - Stephen J. Klawa
- Department of Applied Physical Sciences, University of North Carolina, Chapel Hill, North Carolina 27599, United States
| | - Tengyue Jian
- Department of Applied Physical Sciences, University of North Carolina, Chapel Hill, North Carolina 27599, United States
| | - Sanghoon Kim
- Department of Applied Physical Sciences, University of North Carolina, Chapel Hill, North Carolina 27599, United States
| | - Micah J. Papanikolas
- Department of Applied Physical Sciences, University of North Carolina, Chapel Hill, North Carolina 27599, United States
| | - Ronit Freeman
- Department of Applied Physical Sciences, University of North Carolina, Chapel Hill, North Carolina 27599, United States
| | - Zachary D. Schultz
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, United States
| |
Collapse
|
81
|
Payne TD, Klawa SJ, Jian T, Kim SH, Papanikolas MJ, Freeman R, Schultz ZD. Catching COVID: Engineering Peptide-Modified Surface-Enhanced Raman Spectroscopy Sensors for SARS-CoV-2. ACS Sens 2021. [PMID: 34491043 DOI: 10.1021/acssensors.1c0134410.1021/acssensors.1c01344.s001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/10/2023]
Abstract
COVID-19 remains an ongoing issue across the globe, highlighting the need for a rapid, selective, and accurate sensor for SARS-CoV-2 and its emerging variants. The chemical specificity and signal amplification of surface-enhanced Raman spectroscopy (SERS) could be advantageous for developing a quantitative assay for SARS-CoV-2 with improved speed and accuracy over current testing methods. Here, we have tackled the challenges associated with SERS detection of viruses. As viruses are large, multicomponent species, they can yield different SERS signals, but also other abundant biomolecules present in the sample can generate undesired signals. To improve selectivity in complex biological environments, we have employed peptides as capture probes for viral proteins and developed an angiotensin-converting enzyme 2 (ACE2) mimetic peptide-based SERS sensor for SARS-CoV-2. The unique vibrational signature of the spike protein bound to the peptide-modified surface is identified and used to construct a multivariate calibration model for quantification. The sensor demonstrates a 300 nM limit of detection and high selectivity in the presence of excess bovine serum albumin. This work provides the basis for designing a SERS-based assay for the detection of SARS-CoV-2 as well as engineering SERS biosensors for other viruses in the future.
Collapse
Affiliation(s)
- Taylor D Payne
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, United States
| | - Stephen J Klawa
- Department of Applied Physical Sciences, University of North Carolina, Chapel Hill, North Carolina 27599, United States
| | - Tengyue Jian
- Department of Applied Physical Sciences, University of North Carolina, Chapel Hill, North Carolina 27599, United States
| | - Sang Hoon Kim
- Department of Applied Physical Sciences, University of North Carolina, Chapel Hill, North Carolina 27599, United States
| | - Micah J Papanikolas
- Department of Applied Physical Sciences, University of North Carolina, Chapel Hill, North Carolina 27599, United States
| | - Ronit Freeman
- Department of Applied Physical Sciences, University of North Carolina, Chapel Hill, North Carolina 27599, United States
| | - Zachary D Schultz
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, United States
| |
Collapse
|
82
|
Yoon BK, Sut TN, Yoo KY, Lee SH, Hwang Y, Jackman JA, Cho NJ. Lipid bilayer coatings for rapid enzyme-linked immunosorbent assay. APPLIED MATERIALS TODAY 2021; 24:101128. [PMID: 34395822 PMCID: PMC8354060 DOI: 10.1016/j.apmt.2021.101128] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Revised: 07/14/2021] [Accepted: 07/19/2021] [Indexed: 06/04/2023]
Abstract
The enzyme-linked immunosorbent assay (ELISA) is a widely used method for protein detection and relies on the specific capture of target proteins while minimizing the nonspecific binding of other interfering proteins and biomolecules. To prevent nonspecific binding events, blocking agents such as bovine serum albumin (BSA) protein, mixtures of proteins in media such as milk or serum, and/or surfactants are typically added to ELISA plates after probe attachment and before analyte capture. Herein, we developed a streamlined ELISA strategy in which readily prepared lipid nanoparticles are utilized as the blocking agent and are added together with the probe molecule to the ELISA plate, resulting in fewer processing steps, quicker protocol time, and superior detection performance compared to conventional BSA blocking. These measurement capabilities were established for coronavirus disease-2019 (COVID-19) antibody detection in saline and human serum conditions and are broadly applicable for developing rapid ELISA diagnostics.
Collapse
Affiliation(s)
- Bo Kyeong Yoon
- School of Chemical Engineering and Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Tun Naw Sut
- School of Chemical Engineering and Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon 16419, Republic of Korea
- School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Ki Yeol Yoo
- LUCA Health and LUCA AICell, Inc., Anyang 14055, Republic of Korea
| | - Seung Hwa Lee
- LUCA Health and LUCA AICell, Inc., Anyang 14055, Republic of Korea
| | - Youngkyu Hwang
- School of Chemical Engineering and Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon 16419, Republic of Korea
- School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Joshua A Jackman
- School of Chemical Engineering and Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Nam-Joon Cho
- School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798, Singapore
| |
Collapse
|
83
|
Roadmap on Universal Photonic Biosensors for Real-Time Detection of Emerging Pathogens. PHOTONICS 2021. [DOI: 10.3390/photonics8080342] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
The COVID-19 pandemic has made it abundantly clear that the state-of-the-art biosensors may not be adequate for providing a tool for rapid mass testing and population screening in response to newly emerging pathogens. The main limitations of the conventional techniques are their dependency on virus-specific receptors and reagents that need to be custom-developed for each recently-emerged pathogen, the time required for this development as well as for sample preparation and detection, the need for biological amplification, which can increase false positive outcomes, and the cost and size of the necessary equipment. Thus, new platform technologies that can be readily modified as soon as new pathogens are detected, sequenced, and characterized are needed to enable rapid deployment and mass distribution of biosensors. This need can be addressed by the development of adaptive, multiplexed, and affordable sensing technologies that can avoid the conventional biological amplification step, make use of the optical and/or electrical signal amplification, and shorten both the preliminary development and the point-of-care testing time frames. We provide a comparative review of the existing and emergent photonic biosensing techniques by matching them to the above criteria and capabilities of preventing the spread of the next global pandemic.
Collapse
|
84
|
Zaczek-Moczydlowska MA, Beizaei A, Dillon M, Campbell K. Current state-of-the-art diagnostics for Norovirus detection: Model approaches for point-of-care analysis. Trends Food Sci Technol 2021. [DOI: 10.1016/j.tifs.2021.06.027] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
85
|
Electrochemical approach for the aptamer-like conformational changes of α-synuclein peptides in the presence of copper(II). Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138534] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
86
|
Khairil Anwar NA, Mohd Nazri MN, Murtadha AH, Mohd Adzemi ER, Balakrishnan V, Mustaffa KMF, Tengku Din TADAA, Yahya MM, Haron J, Mokshtar NF. Prognostic prospect of soluble programmed cell death ligand-1 in cancer management. Acta Biochim Biophys Sin (Shanghai) 2021; 53:961-978. [PMID: 34180502 DOI: 10.1093/abbs/gmab077] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Indexed: 12/17/2022] Open
Abstract
Aggressive tissue biopsy is commonly unavoidable in the management of most suspected tumor cases to conclusively verify the presence of cancerous cells through histological assessment. The extracted tissue is also immunostained for detection of antigens (tissue tumor markers) of potential prognostic or therapeutic importance to assist in treatment decision. Although liquid biopsies can be a powerful tool for monitoring treatment response, they are still excluded from standard cancer diagnostics, and their utility is still being debated in the scientific community. With a myriad of soluble tissue tumor markers now being discovered, liquid biopsies could completely change the current paradigms of cancer management. Recently, soluble programmed cell death ligand-1 (sPD-L1), which is found in the peripheral blood, i.e. serum and plasma, has shown potential as a pre-therapeutic predictive marker as well as a prognostic biomarker to monitor treatment efficacy. Thus, this review focuses on the emergence of sPD-L1 and promising technologies for its detection in order to support liquid biopsies for future cancer management.
Collapse
Affiliation(s)
- Nur Amira Khairil Anwar
- Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, Kubang Kerian, Kelantan 16150, Malaysia
| | - Muhammad Najmi Mohd Nazri
- Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, Kubang Kerian, Kelantan 16150, Malaysia
| | - Ahmad Hafiz Murtadha
- Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, Kubang Kerian, Kelantan 16150, Malaysia
| | - Elis Rosliza Mohd Adzemi
- Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, Kubang Kerian, Kelantan 16150, Malaysia
| | - Venugopal Balakrishnan
- Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, Kubang Kerian, Kelantan 16150, Malaysia
| | - Khairul Mohd Fadzli Mustaffa
- Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, Kubang Kerian, Kelantan 16150, Malaysia
| | | | - Maya Mazuwin Yahya
- Breast Cancer Awareness & Research Unit (BestARi), Hospital Universiti Sains Malaysia, Universiti Sains Malaysia, Kota Bharu, Kelantan 16150, Malaysia
| | - Juhara Haron
- Breast Cancer Awareness & Research Unit (BestARi), Hospital Universiti Sains Malaysia, Universiti Sains Malaysia, Kota Bharu, Kelantan 16150, Malaysia
| | - Noor Fatmawati Mokshtar
- Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, Kubang Kerian, Kelantan 16150, Malaysia
| |
Collapse
|
87
|
Silva MLS. Microfluidic devices for glycobiomarker detection in cancer. Clin Chim Acta 2021; 521:229-243. [PMID: 34273337 DOI: 10.1016/j.cca.2021.07.013] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 07/07/2021] [Accepted: 07/12/2021] [Indexed: 12/20/2022]
Abstract
During oncogenesis, several alterations occur within cells, one of them being the abnormal glycosylation of proteins, resulting in the formation of glycoproteins with aberrant glycan structures, which can be secreted into the blood stream. Their specific association to tumour cells makes them useful indicators (biomarkers) of the oncogenic process and their detection in blood can be employed in different stages of tumour development for early detection, prognosis and therapeutic drug monitoring. Due to the importance of detecting cancer-associated glycoproteins with aberrant glycosylation in blood or serum, analytical methodologies with improved performance are required to ameliorate the laboratorial tests currently used for the detection of these analytes. Microfluidics was created to facilitate the implementation of simple and point-of-care analysis, away from a centralized laboratory. The massive use of microfluidic systems in clinical settings can be seen in pregnancy tests and diabetes control, for example. But what about other clinical domains, such as the detection of glycoproteins with aberrant glycans secreted by tumour cells? Are microfluidic systems helpful in this case? This review analyses the requirements of a microfluidic assay for the detection of low-abundant blood/serum cancer-associated glycoproteins with abnormal glycans and the progresses that have been made in the last years to develop integrated microfluidic devices for this particular application. The diverse microfluidic systems found in literature present, in general, the same analytical performance as the conventional assays but have additional advantages, namely a reduction in assay times, a decrease of sample and reagent consumption and lower costs. The review will also focus on the improvements that are still needed for better biosensing of this type of cancer biomarkers using microfluidic devices.
Collapse
Affiliation(s)
- M Luísa S Silva
- Centre of Chemical Research, Autonomous University of Hidalgo State, Carr. Pachuca-Tulancingo km 4.5, Pachuca, Hidalgo 42076, Mexico.
| |
Collapse
|
88
|
Baykal B, Kadikoylu G, Senturk H, Donar YO, Sınağ A, Erdem A. Preparation and characterization gallic acid-titanium dioxide nanocomposites for biosensing application on voltammetric detection of DNA. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
89
|
D’Agata R, Bellassai N, Jungbluth V, Spoto G. Recent Advances in Antifouling Materials for Surface Plasmon Resonance Biosensing in Clinical Diagnostics and Food Safety. Polymers (Basel) 2021; 13:1929. [PMID: 34200632 PMCID: PMC8229487 DOI: 10.3390/polym13121929] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 06/07/2021] [Accepted: 06/07/2021] [Indexed: 01/11/2023] Open
Abstract
Strategies to develop antifouling surface coatings are crucial for surface plasmon resonance (SPR) sensing in many analytical application fields, such as detecting human disease biomarkers for clinical diagnostics and monitoring foodborne pathogens and toxins involved in food quality control. In this review, firstly, we provide a brief discussion with considerations about the importance of adopting appropriate antifouling materials for achieving excellent performances in biosensing for food safety and clinical diagnosis. Secondly, a non-exhaustive landscape of polymeric layers is given in the context of surface modification and the mechanism of fouling resistance. Finally, we present an overview of some selected developments in SPR sensing, emphasizing applications of antifouling materials and progress to overcome the challenges related to the detection of targets in complex matrices relevant for diagnosis and food biosensing.
Collapse
Affiliation(s)
- Roberta D’Agata
- Dipartimento di Scienze Chimiche, Università degli Studi di Catania, Viale Andrea Doria 6, I-95125 Catania, Italy; (N.B.); (V.J.)
| | - Noemi Bellassai
- Dipartimento di Scienze Chimiche, Università degli Studi di Catania, Viale Andrea Doria 6, I-95125 Catania, Italy; (N.B.); (V.J.)
| | - Vanessa Jungbluth
- Dipartimento di Scienze Chimiche, Università degli Studi di Catania, Viale Andrea Doria 6, I-95125 Catania, Italy; (N.B.); (V.J.)
| | - Giuseppe Spoto
- Dipartimento di Scienze Chimiche, Università degli Studi di Catania, Viale Andrea Doria 6, I-95125 Catania, Italy; (N.B.); (V.J.)
- Consorzio Interuniversitario “Istituto Nazionale Biostrutture e Biosistemi”, c/o Dipartimento di Scienze Chimiche, Università di Catania, Viale Andrea Doria 6, I-95125 Catania, Italy
| |
Collapse
|
90
|
Sarcina L, Mangiatordi GF, Torricelli F, Bollella P, Gounani Z, Österbacka R, Macchia E, Torsi L. Surface Plasmon Resonance Assay for Label-Free and Selective Detection of HIV-1 p24 Protein. BIOSENSORS 2021; 11:180. [PMID: 34204930 PMCID: PMC8229864 DOI: 10.3390/bios11060180] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 05/31/2021] [Accepted: 06/01/2021] [Indexed: 11/23/2022]
Abstract
The early detection of the human immunodeficiency virus (HIV) is of paramount importance to achieve efficient therapeutic treatment and limit the disease spreading. In this perspective, the assessment of biosensing assay for the HIV-1 p24 capsid protein plays a pivotal role in the timely and selective detection of HIV infections. In this study, multi-parameter-SPR has been used to develop a reliable and label-free detection method for HIV-1 p24 protein. Remarkably, both physical and chemical immobilization of mouse monoclonal antibodies against HIV-1 p24 on the SPR gold detecting surface have been characterized for the first time. The two immobilization techniques returned a capturing antibody surface coverage as high as (7.5 ± 0.3) × 1011 molecule/cm2 and (2.4 ± 0.6) × 1011 molecule/cm2, respectively. However, the covalent binding of the capturing antibodies through a mixed self-assembled monolayer (SAM) of alkanethiols led to a doubling of the p24 binding signal. Moreover, from the modeling of the dose-response curve, an equilibrium dissociation constant KD of 5.30 × 10-9 M was computed for the assay performed on the SAM modified surface compared to a much larger KD of 7.46 × 10-5 M extracted for the physisorbed antibodies. The chemically modified system was also characterized in terms of sensitivity and selectivity, reaching a limit of detection of (4.1 ± 0.5) nM and an unprecedented selectivity ratio of 0.02.
Collapse
Affiliation(s)
- Lucia Sarcina
- Dipartimento di Chimica, Universita’ degli Studi di Bari A. Moro, 70125 Bari, Italy; (L.S.); (P.B.); (L.T.)
| | | | - Fabrizio Torricelli
- Dipartimento di Ingegneria dell’Informazione, Università degli Studi di Brescia, 25123 Brescia, Italy;
| | - Paolo Bollella
- Dipartimento di Chimica, Universita’ degli Studi di Bari A. Moro, 70125 Bari, Italy; (L.S.); (P.B.); (L.T.)
| | - Zahra Gounani
- Physics, Faculty of Science and Engineering, Åbo Akademi University, 20500 Turku, Finland; (Z.G.); (R.Ö.)
| | - Ronald Österbacka
- Physics, Faculty of Science and Engineering, Åbo Akademi University, 20500 Turku, Finland; (Z.G.); (R.Ö.)
| | - Eleonora Macchia
- Physics, Faculty of Science and Engineering, Åbo Akademi University, 20500 Turku, Finland; (Z.G.); (R.Ö.)
| | - Luisa Torsi
- Dipartimento di Chimica, Universita’ degli Studi di Bari A. Moro, 70125 Bari, Italy; (L.S.); (P.B.); (L.T.)
- Physics, Faculty of Science and Engineering, Åbo Akademi University, 20500 Turku, Finland; (Z.G.); (R.Ö.)
- CSGI (Centre for Colloid and Surface Science), 70125 Bari, Italy
| |
Collapse
|
91
|
ESSENCE – A rapid, shear-enhanced, flow-through, capacitive electrochemical platform for rapid detection of biomolecules. Biosens Bioelectron 2021; 182:113163. [DOI: 10.1016/j.bios.2021.113163] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 02/25/2021] [Accepted: 03/10/2021] [Indexed: 01/24/2023]
|
92
|
Fan R, Du J, Park KW, Chang LH, Strieter ER, Andrew TL. Immobilization of Nanobodies with Vapor-Deposited Polymer Encapsulation for Robust Biosensors. ACS APPLIED POLYMER MATERIALS 2021; 3:2561-2567. [PMID: 34296186 PMCID: PMC8293903 DOI: 10.1021/acsapm.1c00140] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
To produce next-generation, shelf-stable biosensors for point-of-care diagnostics, a combination of rugged biomolecular recognition elements, efficient encapsulants, and innocuous deposition approaches is needed. Furthermore, to ensure that the sensitivity and specificity that are inherent to biological recognition elements are maintained in solid-state biosensing systems, site-specific immobilization chemistries must be invoked such that the function of the biomolecule remains unperturbed. In this work, we present a widely applicable strategy to develop robust solid-state biosensors using emergent nanobody (Nb) recognition elements coupled with a vapor-deposited polymer encapsulation layer. As compared to conventional immunoglobulin G antibodies, Nbs are smaller (12-15 kDa as opposed to ~150 kDa), have higher thermal stability and pH tolerance, boast greater ease of recombinant production, and are capable of binding antigens with high affinity and specificity. Photoinitiated chemical vapor deposition affords thin, protective polymer barrier layers over immobilized Nb arrays that allow for retention of Nb activity and specificity after both storage under ambient conditions and complete desiccation. Most importantly, we also demonstrate that vapor-deposited polymer encapsulation of Nb arrays enables specific detection of target proteins in complex heterogeneous samples, such as unpurified cell lysate, which is otherwise challenging to achieve with bare Nb arrays.
Collapse
Affiliation(s)
- Ruolan Fan
- Department of Chemistry, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - Jiale Du
- Department of Chemistry, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - Kwang-Won Park
- Department of Chemistry, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - Lin Hui Chang
- Department of Chemistry, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - Eric R Strieter
- Department of Chemistry, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - Trisha L Andrew
- Department of Chemistry and Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| |
Collapse
|
93
|
DeBari MK, Niu X, Scott JV, Griffin MD, Pereira SR, Cook KE, He B, Abbott RD. Therapeutic Ultrasound Triggered Silk Fibroin Scaffold Degradation. Adv Healthc Mater 2021; 10:e2100048. [PMID: 33738976 DOI: 10.1002/adhm.202100048] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2021] [Revised: 02/22/2021] [Indexed: 01/03/2023]
Abstract
A patient's capacity for tissue regeneration varies based on age, nutritional status, disease state, lifestyle, and gender. Because regeneration cannot be predicted prior to biomaterial implantation, there is a need for responsive biomaterials with adaptive, personalized degradation profiles to improve regenerative outcomes. This study reports a new approach to use therapeutic ultrasound as a means of altering the degradation profile of silk fibroin biomaterials noninvasively postimplantation. By evaluating changes in weight, porosity, surface morphology, compressive modulus, and chemical structure, it is concluded that therapeutic ultrasound can trigger enhanced degradation of silk fibroin scaffolds noninvasively. By removing microbubbles on the scaffold surface, it is found that acoustic cavitation is the mechanism responsible for changing the degradation profile. This method is proved to be safe for human cells with no negative effects on cell viability or metabolism. Sonication through human skin also effectively triggers scaffold degradation, increasing the clinical relevance of these results. These findings suggest that silk is an ultrasound-responsive biomaterial, where the degradation profile can be adjusted noninvasively to improve regenerative outcomes.
Collapse
Affiliation(s)
- Megan K. DeBari
- Department of Materials Science and Engineering Carnegie Mellon University 5000 Forbes Ave Pittsburgh PA 15213 USA
| | - Xiaodan Niu
- Department of Biomedical Engineering Carnegie Mellon University 5000 Forbes Ave Pittsburgh PA 15213 USA
| | - Jacqueline V. Scott
- Department of Biomedical Engineering Carnegie Mellon University 5000 Forbes Ave Pittsburgh PA 15213 USA
| | - Mallory D. Griffin
- Department of Biomedical Engineering Carnegie Mellon University 5000 Forbes Ave Pittsburgh PA 15213 USA
| | - Sean R. Pereira
- Department of Biomedical Engineering Carnegie Mellon University 5000 Forbes Ave Pittsburgh PA 15213 USA
| | - Keith E. Cook
- Department of Biomedical Engineering Carnegie Mellon University 5000 Forbes Ave Pittsburgh PA 15213 USA
| | - Bin He
- Department of Biomedical Engineering Carnegie Mellon University 5000 Forbes Ave Pittsburgh PA 15213 USA
| | - Rosalyn D. Abbott
- Department of Biomedical Engineering Carnegie Mellon University 5000 Forbes Ave Pittsburgh PA 15213 USA
| |
Collapse
|
94
|
Ashcraft M, Douglass M, Chen Y, Handa H. Combination strategies for antithrombotic biomaterials: an emerging trend towards hemocompatibility. Biomater Sci 2021; 9:2413-2423. [PMID: 33599226 PMCID: PMC8035307 DOI: 10.1039/d0bm02154g] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Surface-induced thrombosis is a frequent, critical issue for blood-contacting medical devices that poses a serious threat to patient safety and device functionality. Antithrombotic material design strategies including the immobilization of anticoagulants, alterations in surface chemistries and morphology, and the release of antithrombotic compounds have made great strides in the field with the ultimate goal of circumventing the need for systemic anticoagulation, but have yet to achieve the same hemocompatibility as the native endothelium. Given that the endothelium achieves this state through the use of many mechanisms of action, there is a rising trend in combining these established design strategies for improved antithrombotic actions. Here, we describe this emerging paradigm, highlighting the apparent advantages of multiple antithrombotic mechanisms of action and discussing the demonstrated potential of this new direction.
Collapse
Affiliation(s)
- Morgan Ashcraft
- School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia 30602, USA.
| | | | | | | |
Collapse
|
95
|
Florkiewicz W, Słota D, Placek A, Pluta K, Tyliszczak B, Douglas TEL, Sobczak-Kupiec A. Synthesis and Characterization of Polymer-Based Coatings Modified with Bioactive Ceramic and Bovine Serum Albumin. J Funct Biomater 2021; 12:21. [PMID: 33808394 PMCID: PMC8103286 DOI: 10.3390/jfb12020021] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 03/18/2021] [Accepted: 03/26/2021] [Indexed: 12/14/2022] Open
Abstract
This study involves the synthesis of hydroxyapatite and describes the preparation and characterization of polymer coatings based on poly(ethylene glycol) diacrylate and poly(ethylene glycol) and modified with bovine serum albumin and hydroxyapatite. Hydroxyapatite was obtained by wet chemical synthesis and characterized by X-ray diffraction and FTIR spectroscopy, and its Ca/P molar ratio was determined (1.69 ± 0.08). The ceramic and bovine serum albumin were used in the preparation of composite materials with the polymeric matrix. The chemical composition of coatings was characterized with FTIR spectroscopy, and their morphology was recorded with SEM imaging. Moreover, the measurements of surface roughness parameters and stereometric research were performed. The prepared coatings were subjected to in vitro studies in simulated body fluid and artificial saliva. Changes in chemical composition and morphology after immersion were examined with FTIR spectroscopy and SEM imaging. Based on the conducted research, it can be stated that applied modifiers promote the biomineralization process. The roughness analysis confirmed prepared materials were characterized by the micrometer-scale topography. The materials morphology and roughness, and the morphology of the newly formed apatite deposit, were dependent on the type of the used modifier, and the artificial fluid used in in vitro studies.
Collapse
Affiliation(s)
- Wioletta Florkiewicz
- Institute of Materials Science, Faculty of Materials Science and Physics, Cracow University of Technology, 37 Jana Pawła II Av., 31-864 Krakow, Poland; (W.F.); (B.T.); (A.S.-K.)
| | - Dagmara Słota
- Institute of Materials Science, Faculty of Materials Science and Physics, Cracow University of Technology, 37 Jana Pawła II Av., 31-864 Krakow, Poland; (W.F.); (B.T.); (A.S.-K.)
| | - Angelika Placek
- Institute of Inorganic Chemistry and Technology, Cracow University of Technology, 24 Warszawska St., 31-155 Krakow, Poland; (A.P.); (K.P.)
| | - Klaudia Pluta
- Institute of Inorganic Chemistry and Technology, Cracow University of Technology, 24 Warszawska St., 31-155 Krakow, Poland; (A.P.); (K.P.)
| | - Bożena Tyliszczak
- Institute of Materials Science, Faculty of Materials Science and Physics, Cracow University of Technology, 37 Jana Pawła II Av., 31-864 Krakow, Poland; (W.F.); (B.T.); (A.S.-K.)
| | - Timothy E. L. Douglas
- Engineering Department, Lancaster University, Gillow Av., Lancaster LA1 4YW, UK;
- Materials Science Institute, Lancaster University, Gillow Av., Lancaster LA1 4YW, UK
| | - Agnieszka Sobczak-Kupiec
- Institute of Materials Science, Faculty of Materials Science and Physics, Cracow University of Technology, 37 Jana Pawła II Av., 31-864 Krakow, Poland; (W.F.); (B.T.); (A.S.-K.)
| |
Collapse
|
96
|
Krivitsky V, Granot E, Avidor Y, Borberg E, Voegele RT, Patolsky F. Rapid Collection and Aptamer-Based Sensitive Electrochemical Detection of Soybean Rust Fungi Airborne Urediniospores. ACS Sens 2021; 6:1187-1198. [PMID: 33507747 PMCID: PMC8023804 DOI: 10.1021/acssensors.0c02452] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Accepted: 01/20/2021] [Indexed: 02/07/2023]
Abstract
Plants are the central source of food for humans around the world. Unfortunately, plants can be negatively affected by diverse kinds of diseases that are responsible for major economic losses worldwide. Thus, monitoring plant health and early detection of pathogens are essential to reduce disease spread and facilitate effective management practices. Various detection approaches are currently practiced. These methods mainly include visual inspection and laboratory tests. Nonetheless, these methods are labor-intensive, time-consuming, expensive, and inefficient in the early stages of infection. Thus, it is extremely important to detect diseases at the early stages of the epidemic. Here, we would like to present a fast, sensitive, and reliable electrochemical sensing platform for the detection of airborne soybean rust spores. The suspected airborne soybean rust spores are first collected and trapped inside a carbon 3D electrode matrix by high-capacity air-sampling means. Then, a specific biotinylated aptamer, suitable to target specific sites of soybean rust spores is applied. This aptamer agent binds to the surface of the collected spores on the electrode. Finally, spore-bound aptamer units are incubated with a streptavidin-alkaline phosphatase agent leading to the enzymatic formation of p-nitrophenol, which is characterized by its unique electrochemical properties. Our method allows for the rapid (ca. 2 min), selective, and sensitive collection and detection of soybean rust spores (down to the limit of 100-200 collected spores per cm2 of electrode area). This method could be further optimized for its sensitivity and applied to the future multiplex early detection of various airborne plant diseases.
Collapse
Affiliation(s)
- Vadim Krivitsky
- School
of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 69978, Israel
| | - Eran Granot
- School
of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 69978, Israel
| | | | - Ella Borberg
- School
of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 69978, Israel
| | - Ralf T. Voegele
- Institute
of Phytomedicine, University of Hohenheim, Stuttgart 70599, Germany
| | - Fernando Patolsky
- School
of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 69978, Israel
- Department
of Materials Science and Engineering, the Iby and Aladar Fleischman
Faculty of Engineering, Tel Aviv University, Tel Aviv 69978, Israel
| |
Collapse
|
97
|
Alhamoud Y, Li Y, Zhou H, Al-Wazer R, Gong Y, Zhi S, Yang D. Label-Free and Highly-Sensitive Detection of Ochratoxin A Using One-Pot Synthesized Reduced Graphene Oxide/Gold Nanoparticles-Based Impedimetric Aptasensor. BIOSENSORS 2021; 11:87. [PMID: 33808613 PMCID: PMC8003581 DOI: 10.3390/bios11030087] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 03/10/2021] [Accepted: 03/16/2021] [Indexed: 01/13/2023]
Abstract
Ochratoxin A (OTA) primarily obtained by the genera aspergillus and penicillium, is one of the toxic substances for different organs and systems of the human body such as the kidney, liver, neurons and the immune system. Moreover, it is considered to cause tumors and fetal malformation even at a very low concentration. Fast and sensitive assay for detection of OTA at ultralow levels in foods and agricultural products has been an increasing demand. In this study, a new label-free electrochemical biosensor based on three-dimensional reduced graphene oxide/gold nanoparticles/aptamer for OTA detection was constructed. The 3D-rGO/Au NPs nanocomposites were firstly synthesized using a one-pot hydrothermal process under optimized experimental conditions. The 3D-rGO/Au NPs with considerable particular surface area and outstanding electrical conductivity was then coated on a glass carbon electrode to provide tremendous binding sites for -SH modified aptamer via the distinctive Au-S linkage. The presence of OTA was specifically captured by aptamer and resulted in electrochemical impedance spectroscopy (EIS) signal response accordingly. The constructed impedimetric aptasensor obtained a broad linear response from 1 pg/mL to 10 ng/mL with an LOD of 0.34 pg/mL toward OTA detection, highlighting the excellent sensitivity. Satisfactory reproducibility was also achieved with the relative standard deviation (RSD) of 1.393%. Moreover, the proposed aptasensor obtained a good recovery of OTA detection in red wine samples within the range of 93.14 to 112.75% along with a low LOD of 0.023 ng/mL, indicating its applicability for OTA detection in real samples along with economical, specific, susceptible, fast, easy, and transportable merits.
Collapse
Affiliation(s)
- Yasmin Alhamoud
- Zhejiang Key Laboratory of Pathophysiology, Department of Preventative Medicine, School of Medicine, Ningbo University, 818 Fenghua Road, Ningbo 315211, China; (Y.A.); (Y.L.); (Y.G.)
| | - Yingying Li
- Zhejiang Key Laboratory of Pathophysiology, Department of Preventative Medicine, School of Medicine, Ningbo University, 818 Fenghua Road, Ningbo 315211, China; (Y.A.); (Y.L.); (Y.G.)
| | - Haibo Zhou
- Institute of Pharmaceutical Analysis and Guangdong Province Key Laboratory of Pharmacodynamic Constituents of Traditional Chinese Medicine & New Drug Research, College of Pharmacy, Jinan University, Guangzhou 510632, China;
| | - Ragwa Al-Wazer
- Department of Pharmacy, Faculty of Applied Medical Sciences, Yemeni Jordanian University, 1833 Sana’a, Yemen;
| | - Yiying Gong
- Zhejiang Key Laboratory of Pathophysiology, Department of Preventative Medicine, School of Medicine, Ningbo University, 818 Fenghua Road, Ningbo 315211, China; (Y.A.); (Y.L.); (Y.G.)
| | - Shuai Zhi
- Zhejiang Key Laboratory of Pathophysiology, Department of Preventative Medicine, School of Medicine, Ningbo University, 818 Fenghua Road, Ningbo 315211, China; (Y.A.); (Y.L.); (Y.G.)
| | - Danting Yang
- Zhejiang Key Laboratory of Pathophysiology, Department of Preventative Medicine, School of Medicine, Ningbo University, 818 Fenghua Road, Ningbo 315211, China; (Y.A.); (Y.L.); (Y.G.)
| |
Collapse
|
98
|
Mendez-Gonzalez D, Silva-Ibáñez PP, Valiente-Dies F, Calderón OG, Mendez-Gonzalez JL, Laurenti M, Egatz-Gómez A, Díaz E, Rubio-Retama J, Melle S. Oligonucleotide sensor based on magnetic capture and photoligation of upconverting nanoparticles in solid surfaces. J Colloid Interface Sci 2021; 596:64-74. [PMID: 33838326 DOI: 10.1016/j.jcis.2021.02.093] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Revised: 01/25/2021] [Accepted: 02/21/2021] [Indexed: 10/21/2022]
Abstract
In this work, we present a luminescence platform that can be used as point of care system for determining the presence and concentration of specific oligonucleotide sequences. This sensor exhibited a limit of detection as low as 50 fM by means of: (i) the use of single-stranded DNA (ssDNA) functionalized magnetic microparticles that captured and concentrated ssDNA-upconverting nanoparticles (ssDNA-UCNPs) on a solid support, when the target sequence (miR-21-5p DNA-analogue) was in the sample, and (ii) a photoligation reaction that covalently linked the ssDNA-UCNPs and the ssDNA magnetic microparticles, allowing stringent washes. The presented sensor showed a similar limit of detection when the assays were conducted in samples containing total miRNA extracted from human serum, demonstrating its suitability for detecting small specific oligonucleotide sequences under real-like conditions. The strategy of combining UCNPs, magnetic microparticles, and a photoligation reaction provides new insight into low-cost, rapid, and ultra-sensitive detection of oligonucleotide sequences.
Collapse
Affiliation(s)
- Diego Mendez-Gonzalez
- Department of Chemistry in Pharmaceutical Sciences, Complutense University of Madrid, E-28040 Madrid, Spain.
| | - Pedro P Silva-Ibáñez
- Department of Chemistry in Pharmaceutical Sciences, Complutense University of Madrid, E-28040 Madrid, Spain; Department of Animal Science, University of Concepción, Chillán, Chile
| | - Fernando Valiente-Dies
- Department of Chemistry in Pharmaceutical Sciences, Complutense University of Madrid, E-28040 Madrid, Spain; GISC, Department of Materials Physics, Complutense University of Madrid, E-28040 Madrid, Spain
| | - Oscar G Calderón
- Department of Optics, Complutense University of Madrid, E-28037 Madrid, Spain
| | - Juan L Mendez-Gonzalez
- Institute of Optics, Consejo Superior de Investigaciones Científicas (CSIC), E-28006 Madrid, Spain
| | - Marco Laurenti
- Department of Chemistry in Pharmaceutical Sciences, Complutense University of Madrid, E-28040 Madrid, Spain; Instituto de Ciencia de Materiales de Madrid, c/Sor Juana Inés de la Cruz, Cantoblanco, 28049 Madrid, Spain; Instituto Ramón y Cajal de Investigación Sanitaria, Hospital Universitario Ramón y Cajal, 28034 Madrid, Spain
| | - Ana Egatz-Gómez
- Department of Optics, Complutense University of Madrid, E-28037 Madrid, Spain; Center for Applied Structural Discovery, The Biodesign Institute, Arizona State University, Tempe, AZ 85281, United States
| | - Elena Díaz
- GISC, Department of Materials Physics, Complutense University of Madrid, E-28040 Madrid, Spain
| | - Jorge Rubio-Retama
- Department of Chemistry in Pharmaceutical Sciences, Complutense University of Madrid, E-28040 Madrid, Spain
| | - Sonia Melle
- Department of Optics, Complutense University of Madrid, E-28037 Madrid, Spain.
| |
Collapse
|
99
|
Esposito F, Sansone L, Srivastava A, Baldini F, Campopiano S, Chiavaioli F, Giordano M, Giannetti A, Iadicicco A. Long period grating in double cladding fiber coated with graphene oxide as high-performance optical platform for biosensing. Biosens Bioelectron 2021; 172:112747. [PMID: 33129073 PMCID: PMC7581380 DOI: 10.1016/j.bios.2020.112747] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 10/11/2020] [Accepted: 10/18/2020] [Indexed: 01/08/2023]
Abstract
In this work, the development and testing of a novel fiber-optic based label-free biosensor is presented, whose performance were verified through the detection of C-reactive protein (CRP) in serum. The device is based on a long period grating fabricated in a double cladding fiber with a W-shaped refractive index (RI) profile. As a result, the working point of the device was tuned to the mode transition region by chemical etching of the outer fiber cladding, obtaining a significant enhancement of the RI sensitivity and an excellent visibility of the grating resonances due to the mode transition in an all-silica structure. The fiber transducer was coated with a nanometric thin layer of graphene oxide in order to provide functional groups for the covalent immobilization of the biological recognition element. A very low limit of detection of about 0.15 ng/mL was obtained during the detection of CRP in serum, and a large working range (1 ng/mL - 100 μg/mL) of clinical relevance has been also achieved.
Collapse
Affiliation(s)
- Flavio Esposito
- Department of Engineering, University of Naples "Parthenope", Centro Direzionale Isola C4, 80143, Napoli, Italy
| | - Lucia Sansone
- Institute for Polymers, Composites and Biomaterials, National Research Council of Italy (CNR), 80055, Portici, Italy
| | - Anubhav Srivastava
- Department of Engineering, University of Naples "Parthenope", Centro Direzionale Isola C4, 80143, Napoli, Italy
| | - Francesco Baldini
- Institute of Applied Physics "Nello Carrara", National Research Council of Italy (CNR), 50019, Sesto Fiorentino, Italy
| | - Stefania Campopiano
- Department of Engineering, University of Naples "Parthenope", Centro Direzionale Isola C4, 80143, Napoli, Italy
| | - Francesco Chiavaioli
- Institute of Applied Physics "Nello Carrara", National Research Council of Italy (CNR), 50019, Sesto Fiorentino, Italy.
| | - Michele Giordano
- Institute for Polymers, Composites and Biomaterials, National Research Council of Italy (CNR), 80055, Portici, Italy.
| | - Ambra Giannetti
- Institute of Applied Physics "Nello Carrara", National Research Council of Italy (CNR), 50019, Sesto Fiorentino, Italy
| | - Agostino Iadicicco
- Department of Engineering, University of Naples "Parthenope", Centro Direzionale Isola C4, 80143, Napoli, Italy
| |
Collapse
|
100
|
Mahmoudi T, Pourhassan-Moghaddam M, Shirdel B, Baradaran B, Morales-Narváez E, Golmohammadi H. (Nano)tag-antibody conjugates in rapid tests. J Mater Chem B 2021; 9:5414-5438. [PMID: 34143173 DOI: 10.1039/d1tb00571e] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Antibodies (Abs) are naturally derived materials with favorable affinity, selectivity, and fast binding kinetics to the respective antigens, which enables their application as promising recognition elements in the development of various types of biosensors/bioassays, especially in rapid tests. These tests are low-cost and easy-to-use biosensing devices with broad applications including medical or veterinary diagnostics, environmental monitoring and industrial usages such as safety and quality analysis in food, providing on-site quick monitoring of various analytes, making it possible to save analysis costs and time. To reach such features, the conjugation of Abs with various nanomaterials (NMs) as tags is necessary, which range from conventional gold nanoparticles to other nanoparticles recently introduced, where magnetic, plasmonic, photoluminescent, or multi-modal properties play a critical role in the overall performance of the analytical device. In this context, to preserve the Ab affinity and provide a rapid response with long-term storage capability, the use of efficient bio-conjugation techniques is critical. Thanks to their prominent role in rapid tests, many studies have been devoted to the design and development of Abs-NMs conjugates with various chemistries including passive adsorption, covalent coupling, and affinity interactions. In this review, we present the state-of-the-art techniques allowing various Ab-NM conjugates with a special focus on the efficiency of the developed probes to be employed in in vitro rapid tests. Challenges and future perspectives on the development of Ab-conjugated nanotags in rapid diagnostic tests are highlighted along with a survey of the progress in commercially available Ab-NM conjugates.
Collapse
Affiliation(s)
- Tohid Mahmoudi
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| | - Mohammad Pourhassan-Moghaddam
- ARC Research Hub for Integrated Device for End-user Analysis at Low-levels (IDEAL), Faculty of Science, University of Technology Sydney, Sydney, NSW 2007, Australia
| | - Behnaz Shirdel
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| | - Behzad Baradaran
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| | - Eden Morales-Narváez
- Biophotonic Nanosensors Laboratory, Centro de Investigaciones en Óptica, A. C. Loma del Bosque 115, Lomas del Campestre, 37150 León, Guanajuato, Mexico.
| | - Hamed Golmohammadi
- Nanosensors Bioplatforms Laboratory, Chemistry and Chemical Engineering Research Center of Iran, 14335-186, Tehran, Iran.
| |
Collapse
|