Marazzi NM, Guidoboni G, Zaid M, Sala L, Ahmad S, Despins L, Popescu M, Skubic M, Keller J. Combining Physiology-Based Modeling and Evolutionary Algorithms for Personalized, Noninvasive Cardiovascular Assessment Based on Electrocardiography and Ballistocardiography. Front Physiol 2022; 12:739035. [PMID: 35095545 PMCID: PMC8790319 DOI: 10.3389/fphys.2021.739035] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Accepted: 10/14/2021] [Indexed: 11/13/2022] Open
Abstract
Purpose: This study proposes a novel approach to obtain personalized estimates of cardiovascular parameters by combining (i) electrocardiography and ballistocardiography for noninvasive cardiovascular monitoring, (ii) a physiology-based mathematical model for predicting personalized cardiovascular variables, and (iii) an evolutionary algorithm (EA) for searching optimal model parameters.Methods: Electrocardiogram (ECG), ballistocardiogram (BCG), and a total of six blood pressure measurements are recorded on three healthy subjects. The R peaks in the ECG are used to segment the BCG signal into single BCG curves for each heart beat. The time distance between R peaks is used as an input for a validated physiology-based mathematical model that predicts distributions of pressures and volumes in the cardiovascular system, along with the associated BCG curve. An EA is designed to search the generation of parameter values of the cardiovascular model that optimizes the match between model-predicted and experimentally-measured BCG curves. The physiological relevance of the optimal EA solution is evaluated a posteriori by comparing the model-predicted blood pressure with a cuff placed on the arm of the subjects to measure the blood pressure.Results: The proposed approach successfully captures amplitudes and timings of the most prominent peak and valley in the BCG curve, also known as the J peak and K valley. The values of cardiovascular parameters pertaining to ventricular function can be estimated by the EA in a consistent manner when the search is performed over five different BCG curves corresponding to five different heart-beats of the same subject. Notably, the blood pressure predicted by the physiology-based model with the personalized parameter values provided by the EA search exhibits a very good agreement with the cuff-based blood pressure measurement.Conclusion: The combination of EA with physiology-based modeling proved capable of providing personalized estimates of cardiovascular parameters and physiological variables of great interest, such as blood pressure. This novel approach opens the possibility for developing quantitative devices for noninvasive cardiovascular monitoring based on BCG sensing.
Collapse
Affiliation(s)
- Nicholas Mattia Marazzi
- Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO, United States
| | - Giovanna Guidoboni
- Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO, United States
- Department of Mathematics, University of Missouri, Columbia, MO, United States
- *Correspondence: Giovanna Guidoboni
| | - Mohamed Zaid
- Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO, United States
| | - Lorenzo Sala
- Centre de Recherche Inria Saclay-Ile de France, Palaiseau, France
| | - Salman Ahmad
- Department of Surgery, School of Medicine, University of Missouri, Columbia, MO, United States
| | - Laurel Despins
- Sinclair School of Nursing, University of Missouri, Columbia, MO, United States
| | - Mihail Popescu
- Department of Health Management and Informatics, School of Medicine, University of Missouri, Columbia, MO, United States
| | - Marjorie Skubic
- Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO, United States
| | - James Keller
- Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO, United States
| |
Collapse
|
102
|
Jung H, Kimball JP, Receveur T, Gazi AH, Agdeppa ED, Inan OT. Estimation of Tidal Volume Using Load Cells on a Hospital Bed. IEEE J Biomed Health Inform 2022; 26:3330-3341. [PMID: 34995200 DOI: 10.1109/jbhi.2022.3141209] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Although respiratory failure is one of the primary causes of admission to intensive care, the importance placed on measurement of respiratory parameters is commonly overshadowed compared to cardiac parameters. With the increased demand for unobtrusive yet quantifi- able respiratory monitoring, many technologies have been proposed recently. However, there are challenges to be addressed for such technologies to enable widespread use. In this work, we explore the feasibility of using load cell sensors embedded on a hospital bed for monitoring respi- ratory rate (RR) and tidal volume (TV). We propose a globalized machine learning (ML)-based algorithm for estimating TV without the requirement of subject-specific calibration or training. In a study of 15 healthy subjects performing respiratory tasks in four different postures, the outputs from four load cell channels and the reference spirometer were recorded simultaneously. A signal processing pipeline was implemented to extract features that capture respira- tory movement and the respiratory effects on the cardiac (i.e., ballistocardiogram, BCG) signals. The proposed RR estimation algorithm achieved a root mean square error (RMSE) of 0.6 breaths per minute (brpm) against the ground truth RR from the spirometer. The TV estimation results demonstrated that combining all three axes of the low- frequency force signals and the BCG heartbeat features best quantifies the respiratory effects of TV. The model resulted in a correlation and RMSE between the estimated and true TV values of 0.85 and 0.23 L, respectively, in the posture independent model without electrocardiogram (ECG) signals. This study suggests that load cell sensors already existing in certain hospital beds can be used for convenient and continuous respiratory monitoring in general care settings.
Collapse
|
103
|
Contactless Cardiogram Reconstruction Based on the Wavelet Transform via Continuous-Wave Radar. ARTIF INTELL 2022. [DOI: 10.1007/978-3-031-20503-3_44] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
104
|
Yazdi D, Sridaran S, Smith S, Centen C, Patel S, Wilson E, Gillon L, Kapur S, Tracy JA, Lewine K, Systrom DM, MacRae CA. Noninvasive Scale Measurement of Stroke Volume and Cardiac Output Compared With the Direct Fick Method: A Feasibility Study. J Am Heart Assoc 2021; 10:e021893. [PMID: 34873927 PMCID: PMC9075258 DOI: 10.1161/jaha.121.021893] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background Objective markers of cardiac function are limited in the outpatient setting and may be beneficial for monitoring patients with chronic cardiac conditions. We assess the accuracy of a scale, with the ability to capture ballistocardiography, electrocardiography, and impedance plethysmography signals from a patient's feet while standing on the scale, in measuring stroke volume and cardiac output compared with the gold-standard direct Fick method. Methods and Results Thirty-two patients with unexplained dyspnea undergoing level 3 invasive cardiopulmonary exercise test at a tertiary medical center were included in the final analysis. We obtained scale and direct Fick measurements of stroke volume and cardiac output before and immediately after invasive cardiopulmonary exercise test. Stroke volume and cardiac output from a cardiac scale and the direct Fick method correlated with r=0.81 and r=0.85, respectively (P<0.001 each). The mean absolute error of the scale estimated stroke volume was -1.58 mL, with a 95% limits of agreement of -21.97 to 18.81 mL. The mean error for the scale estimated cardiac output was -0.31 L/min, with a 95% limits of agreement of -2.62 to 2.00 L/min. The changes in stroke volume and cardiac output before and after exercise were 78.9% and 96.7% concordant, respectively, between the 2 measuring methods. Conclusions In a proof-of-concept study, this novel scale with cardiac monitoring abilities may allow for noninvasive, longitudinal measures of cardiac function. Using the widely accepted form factor of a bathroom scale, this method of monitoring can be easily integrated into a patient's lifestyle.
Collapse
Affiliation(s)
- Daniel Yazdi
- Bodyport IncSan FranciscoCA
- One Brave IdeaBrigham and Women’s HospitalBostonMA
| | | | | | | | | | - Evan Wilson
- One Brave IdeaBrigham and Women’s HospitalBostonMA
| | - Leah Gillon
- One Brave IdeaBrigham and Women’s HospitalBostonMA
| | - Sunil Kapur
- Cardiovascular DivisionBrigham and Women’s HospitalBostonMA
| | - Julie A. Tracy
- Cardiovascular DivisionBrigham and Women’s HospitalBostonMA
| | | | - David M. Systrom
- Division of Pulmonary and Critical Care MedicineDepartment of MedicineBrigham and Women’s HospitalBostonMA
| | - Calum A. MacRae
- One Brave IdeaBrigham and Women’s HospitalBostonMA
- Cardiovascular DivisionBrigham and Women’s HospitalBostonMA
| |
Collapse
|
105
|
Harrington N, Bui QM, Wei Z, Hernandez-Pacheco B, DeYoung PN, Wassell A, Duwaik B, Desai AS, Bhatt DL, Agnihotri P, Owens RL, Coleman TP, King KR. Passive longitudinal weight and cardiopulmonary monitoring in the home bed. Sci Rep 2021; 11:24376. [PMID: 34934065 PMCID: PMC8692625 DOI: 10.1038/s41598-021-03105-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Accepted: 11/22/2021] [Indexed: 01/01/2023] Open
Abstract
Home health monitoring has the potential to improve outpatient management of chronic cardiopulmonary diseases such as heart failure. However, it is often limited by the need for adherence to self-measurement, charging and self-application of wearables, or usage of apps. Here, we describe a non-contact, adherence-independent sensor, that when placed beneath the legs of a patient's home bed, longitudinally monitors total body weight, detailed respiratory signals, and ballistocardiograms for months, without requiring any active patient participation. Accompanying algorithms separate weight and respiratory signals when the bed is shared by a partner or a pet. Validation studies demonstrate quantitative equivalence to commercial sensors during overnight sleep studies. The feasibility of detecting obstructive and central apneas, cardiopulmonary coupling, and the hemodynamic consequences of non-sustained ventricular tachycardia is also established. Real-world durability is demonstrated by 3 months of in-home monitoring in an example patient with heart failure and ischemic cardiomyopathy as he recovers from coronary artery bypass grafting surgery. BedScales is the first sensor to measure adherence-independent total body weight as well as longitudinal cardiopulmonary physiology. As such, it has the potential to create a multidimensional picture of chronic disease, learn signatures of impending hospitalization, and enable optimization of care in the home.
Collapse
Affiliation(s)
- Nicholas Harrington
- Department of Bioengineering, Jacobs School of Engineering, University of California San Diego, 9500 Gilman Dr. MC 0412, La Jolla, CA, 92093, USA
| | - Quan M Bui
- Division of Cardiovascular Medicine, Department of Medicine, University of California San Diego, La Jolla, CA, 92093, USA
| | - Zhe Wei
- Department of Bioengineering, Jacobs School of Engineering, University of California San Diego, 9500 Gilman Dr. MC 0412, La Jolla, CA, 92093, USA
| | - Brandon Hernandez-Pacheco
- Department of Bioengineering, Jacobs School of Engineering, University of California San Diego, 9500 Gilman Dr. MC 0412, La Jolla, CA, 92093, USA
| | - Pamela N DeYoung
- Department of Pulmonary, Critical Care and Sleep Medicine, University of California San Diego, La Jolla, CA, 92093, USA
| | - Andrew Wassell
- Department of Bioengineering, Jacobs School of Engineering, University of California San Diego, 9500 Gilman Dr. MC 0412, La Jolla, CA, 92093, USA
| | - Bayan Duwaik
- Department of Bioengineering, Jacobs School of Engineering, University of California San Diego, 9500 Gilman Dr. MC 0412, La Jolla, CA, 92093, USA
| | - Akshay S Desai
- Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women's Hospital, Boston, MA, 02115, USA
| | - Deepak L Bhatt
- Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women's Hospital, Boston, MA, 02115, USA
| | - Parag Agnihotri
- Population Health Services Organization, University of California San Diego, La Jolla, CA, 92093, USA
| | - Robert L Owens
- Department of Pulmonary, Critical Care and Sleep Medicine, University of California San Diego, La Jolla, CA, 92093, USA
| | - Todd P Coleman
- Department of Bioengineering, Jacobs School of Engineering, University of California San Diego, 9500 Gilman Dr. MC 0412, La Jolla, CA, 92093, USA
| | - Kevin R King
- Department of Bioengineering, Jacobs School of Engineering, University of California San Diego, 9500 Gilman Dr. MC 0412, La Jolla, CA, 92093, USA.
- Division of Cardiovascular Medicine, Department of Medicine, University of California San Diego, La Jolla, CA, 92093, USA.
| |
Collapse
|
106
|
Shokouhmand A, Aranoff ND, Driggin E, Green P, Tavassolian N. Efficient detection of aortic stenosis using morphological characteristics of cardiomechanical signals and heart rate variability parameters. Sci Rep 2021; 11:23817. [PMID: 34893693 PMCID: PMC8664843 DOI: 10.1038/s41598-021-03441-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Accepted: 12/02/2021] [Indexed: 11/30/2022] Open
Abstract
Recent research has shown promising results for the detection of aortic stenosis (AS) using cardio-mechanical signals. However, they are limited by two main factors: lacking physical explanations for decision-making on the existence of AS, and the need for auxiliary signals. The main goal of this paper is to address these shortcomings through a wearable inertial measurement unit (IMU), where the physical causes of AS are determined from IMU readings. To this end, we develop a framework based on seismo-cardiogram (SCG) and gyro-cardiogram (GCG) morphologies, where highly-optimized algorithms are designed to extract features deemed potentially relevant to AS. Extracted features are then analyzed through machine learning techniques for AS diagnosis. It is demonstrated that AS could be detected with 95.49-100.00% confidence. Based on the ablation study on the feature space, the GCG time-domain feature space holds higher consistency, i.e., 95.19-100.00%, with the presence of AS than HRV parameters with a low contribution of 66.00-80.00%. Furthermore, the robustness of the proposed method is evaluated by conducting analyses on the classification of the AS severity level. These analyses are resulted in a high confidence of 92.29%, demonstrating the reliability of the proposed framework. Additionally, game theory-based approaches are employed to rank the top features, among which GCG time-domain features are found to be highly consistent with both the occurrence and severity level of AS. The proposed framework contributes to reliable, low-cost wearable cardiac monitoring due to accurate performance and usage of solitary inertial sensors.
Collapse
Affiliation(s)
- Arash Shokouhmand
- Department of Electrical and Computer Engineering, Stevens Institute of Technology, Hoboken, NJ, 07030, USA
| | - Nicole D Aranoff
- Department of Cardiovascular Medicine, Mount Sinai Morningside Hospital, New York, NY, 10025, USA
| | - Elissa Driggin
- The New York-Presbyterian Hospital, New York, NY, 10065, USA
| | - Philip Green
- Department of Cardiovascular Medicine, Mount Sinai Morningside Hospital, New York, NY, 10025, USA
| | - Negar Tavassolian
- Department of Electrical and Computer Engineering, Stevens Institute of Technology, Hoboken, NJ, 07030, USA.
| |
Collapse
|
107
|
Rabineau J, Nonclercq A, Leiner T, van de Borne P, Migeotte PF, Haut B. Closed-Loop Multiscale Computational Model of Human Blood Circulation. Applications to Ballistocardiography. Front Physiol 2021; 12:734311. [PMID: 34955874 PMCID: PMC8697684 DOI: 10.3389/fphys.2021.734311] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 11/01/2021] [Indexed: 11/13/2022] Open
Abstract
Cardiac mechanical activity leads to periodic changes in the distribution of blood throughout the body, which causes micro-oscillations of the body's center of mass and can be measured by ballistocardiography (BCG). However, many of the BCG findings are based on parameters whose origins are poorly understood. Here, we generate simulated multidimensional BCG signals based on a more exhaustive and accurate computational model of blood circulation than previous attempts. This model consists in a closed loop 0D-1D multiscale representation of the human blood circulation. The 0D elements include the cardiac chambers, cardiac valves, arterioles, capillaries, venules, and veins, while the 1D elements include 55 systemic and 57 pulmonary arteries. The simulated multidimensional BCG signal is computed based on the distribution of blood in the different compartments and their anatomical position given by whole-body magnetic resonance angiography on a healthy young subject. We use this model to analyze the elements affecting the BCG signal on its different axes, allowing a better interpretation of clinical records. We also evaluate the impact of filtering and healthy aging on the BCG signal. The results offer a better view of the physiological meaning of BCG, as compared to previous models considering mainly the contribution of the aorta and focusing on longitudinal acceleration BCG. The shape of experimental BCG signals can be reproduced, and their amplitudes are in the range of experimental records. The contributions of the cardiac chambers and the pulmonary circulation are non-negligible, especially on the lateral and transversal components of the velocity BCG signal. The shapes and amplitudes of the BCG waveforms are changing with age, and we propose a scaling law to estimate the pulse wave velocity based on the time intervals between the peaks of the acceleration BCG signal. We also suggest new formulas to estimate the stroke volume and its changes based on the BCG signal expressed in terms of acceleration and kinetic energy.
Collapse
Affiliation(s)
- Jeremy Rabineau
- TIPs, Université Libre de Bruxelles, Brussels, Belgium
- LPHYS, Université Libre de Bruxelles, Brussels, Belgium
| | | | - Tim Leiner
- Department of Radiology, Utrecht University Medical Center, Utrecht, Netherlands
| | - Philippe van de Borne
- Department of Cardiology, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium
| | | | - Benoit Haut
- TIPs, Université Libre de Bruxelles, Brussels, Belgium
| |
Collapse
|
108
|
Areiza-Laverde H, Dopierala C, Senhadji L, Boucher F, Gumery PY, Hernández A. Analysis of Cardiac Vibration Signals Acquired From a Novel Implant Placed on the Gastric Fundus. Front Physiol 2021; 12:748367. [PMID: 34867453 PMCID: PMC8640497 DOI: 10.3389/fphys.2021.748367] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Accepted: 10/27/2021] [Indexed: 12/25/2022] Open
Abstract
The analysis of cardiac vibration signals has been shown as an interesting tool for the follow-up of chronic pathologies involving the cardiovascular system, such as heart failure (HF). However, methods to obtain high-quality, real-world and longitudinal data, that do not require the involvement of the patient to correctly and regularly acquire these signals, remain to be developed. Implantable systems may be a solution to this observability challenge. In this paper, we evaluate the feasibility of acquiring useful electrocardiographic (ECG) and accelerometry (ACC) data from an innovative implant located in the gastric fundus. In a first phase, we compare data acquired from the gastric fundus with gold standard data acquired from surface sensors on 2 pigs. A second phase investigates the feasibility of deriving useful hemodynamic markers from these gastric signals using data from 4 healthy pigs and 3 pigs with induced HF with longitudinal recordings. The following data processing chain was applied to the recordings: (1) ECG and ACC data denoising, (2) noise-robust real-time QRS detection from ECG signals and cardiac cycle segmentation, (3) Correlation analysis of the cardiac cycles and computation of coherent mean from aligned ECG and ACC, (4) cardiac vibration components segmentation (S1 and S2) from the coherent mean ACC data, and (5) estimation of signal context and a signal-to-noise ratio (SNR) on both signals. Results show a high correlation between the markers acquired from the gastric and thoracic sites, as well as pre-clinical evidence on the feasibility of chronic cardiovascular monitoring from an implantable cardiac device located at the gastric fundus, the main challenge remains on the optimization of the signal-to-noise ratio, in particular for the handling of some sources of noise that are specific to the gastric acquisition site.
Collapse
Affiliation(s)
| | - Cindy Dopierala
- SentinHealth SA, Biopolis, Grenoble, France.,Univ. Grenoble Alpes, CNRS, Grenoble INP, TIMC-IMAG, Grenoble, France
| | | | - Francois Boucher
- Univ. Grenoble Alpes, CNRS, Grenoble INP, TIMC-IMAG, Grenoble, France
| | - Pierre Y Gumery
- Univ. Grenoble Alpes, CNRS, Grenoble INP, TIMC-IMAG, Grenoble, France
| | | |
Collapse
|
109
|
Andreozzi E, Gargiulo GD, Esposito D, Bifulco P. A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds. Front Physiol 2021; 12:725716. [PMID: 34867438 PMCID: PMC8637282 DOI: 10.3389/fphys.2021.725716] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 10/19/2021] [Indexed: 01/14/2023] Open
Abstract
The precordial mechanical vibrations generated by cardiac contractions have a rich frequency spectrum. While the lowest frequencies can be palpated, the higher infrasonic frequencies are usually captured by the seismocardiogram (SCG) signal and the audible ones correspond to heart sounds. Forcecardiography (FCG) is a non-invasive technique that measures these vibrations via force sensing resistors (FSR). This study presents a new piezoelectric sensor able to record all heart vibrations simultaneously, as well as a respiration signal. The new sensor was compared to the FSR-based one to assess its suitability for FCG. An electrocardiogram (ECG) lead and a signal from an electro-resistive respiration band (ERB) were synchronously acquired as references on six healthy volunteers (4 males, 2 females) at rest. The raw signals from the piezoelectric and the FSR-based sensors turned out to be very similar. The raw signals were divided into four components: Forcerespirogram (FRG), Low-Frequency FCG (LF-FCG), High-Frequency FCG (HF-FCG) and heart sounds (HS-FCG). A beat-by-beat comparison of FCG and ECG signals was carried out by means of regression, correlation and Bland–Altman analyses, and similarly for respiration signals (FRG and ERB). The results showed that the infrasonic FCG components are strongly related to the cardiac cycle (R2 > 0.999, null bias and Limits of Agreement (LoA) of ± 4.9 ms for HF-FCG; R2 > 0.99, null bias and LoA of ± 26.9 ms for LF-FCG) and the FRG inter-breath intervals are consistent with ERB ones (R2 > 0.99, non-significant bias and LoA of ± 0.46 s). Furthermore, the piezoelectric sensor was tested against an accelerometer and an electronic stethoscope: synchronous acquisitions were performed to quantify the similarity between the signals. ECG-triggered ensemble averages (synchronized with R-peaks) of HF-FCG and SCG showed a correlation greater than 0.81, while those of HS-FCG and PCG scored a correlation greater than 0.85. The piezoelectric sensor demonstrated superior performances as compared to the FSR, providing more accurate, beat-by-beat measurements. This is the first time that a single piezoelectric sensor demonstrated the ability to simultaneously capture respiration, heart sounds, an SCG-like signal (i.e., HF-FCG) and the LF-FCG signal, which may provide information on ventricular emptying and filling events. According to these preliminary results the novel piezoelectric FCG sensor stands as a promising device for accurate, unobtrusive, long-term monitoring of cardiorespiratory functions and paves the way for a wide range of potential applications, both in the research and clinical fields. However, these results should be confirmed by further analyses on a larger cohort of subjects, possibly including also pathological patients.
Collapse
Affiliation(s)
- Emilio Andreozzi
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Naples, Italy
| | - Gaetano D Gargiulo
- School of Engineering, Design and Built Environment, Western Sydney University, Penrith, NSW, Australia
| | - Daniele Esposito
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Naples, Italy
| | - Paolo Bifulco
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Naples, Italy
| |
Collapse
|
110
|
Hsu PY, Hsu PH, Lee TH, Liu HL. Heart Rate and Respiratory Rate Monitoring Using Seismocardiography. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:6876-6879. [PMID: 34892686 DOI: 10.1109/embc46164.2021.9630298] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Vital signs monitoring is critical for healthcare. Currently, at-home vital signs monitoring is obstructed by the complicated device, unaffordable cost, and inconvenience. In this study, we develop a simultaneous heart rate and respiratory rate monitoring technique that requires only one tri-axial accelerometer placing on the sternum. We devise a signal processing technique to generate seismocardiography and respiratory vibration from the raw acceleration data; furthermore, we formulate the algorithms to compute the heart rate and respiratory rate from the processed signals. We tested the methodology on 20 young healthy adults during pre-exercise and post-exercise sitting. The accuracy of 98.3% and 97.3% are achieved in heart rate monitoring during pre-exercise and post-exercise sitting. For respiratory rate, an accuracy of 96.8% is accomplished. Given the accuracy, affordable cost and convenience, the acceleration-based technique shows great promise for at-home vital signs monitoring.Clinical relevance- Portable heart rate and respiratory rate monitoring is substantial in elevating the quality of healthcare environment.
Collapse
|
111
|
Hsu PY, Hsu PH, Liu HL, Lin KY, Lee TH. Motion Artifact Resilient Cuff-Less Blood Pressure Monitoring Using a Fusion of Multi-Dimensional Seismocardiograms. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:6871-6875. [PMID: 34892685 DOI: 10.1109/embc46164.2021.9629902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Blood pressure (BP) monitoring is critical to raise awareness of hypertension and hypotension, yet the commonly used techniques require the person staying still along with a cuff around the arm. Some cuff-less approaches have been researched, but all hinder the person from moving around. To address the challenge, we propose using a fusion of accelerometers to achieve motion artifact resilient blood pressure monitoring. Such technique is accomplished with the motion artifact removal process and feature extraction from multi-dimensional seismocardiograms. The efficacy of our BP monitoring models is validated in 19 young healthy adults. Both the diastolic and systolic BP monitoring models fulfill the AAMI standard and British Hypertension Society protocol. For sitting still BP monitoring, the mean and standard deviation of diastolic and systolic difference errors (DE) are 0.09 ± 4.10 and -0.25 ± 5.45 mmHg; moreover, the mean absolute difference errors (MADE) are 3.62 and 4.73 mmHg. In walking motions, the DE are 1.15 ±4.47 mmHg for diastolic BP and -0.38 ± 6.67 for systolic BP; furthermore, the MADE are 3.36 and 5.07 mmHg, respectively. The motion artifact resilient cuff-less BP monitoring reveals the potential of portable BP monitoring in healthcare environments.
Collapse
|
112
|
Palumbo F, Crivello A, Furfari F, Girolami M, Mastropietro A, Manferdelli G, Röcke C, Guye S, Salvá Casanovas A, Caon M, Carrino F, Abou Khaled O, Mugellini E, Denna E, Mauri M, Ward D, Subías-Beltrán P, Orte S, Candea C, Candea G, Rizzo G. "Hi This Is NESTORE, Your Personal Assistant": Design of an Integrated IoT System for a Personalized Coach for Healthy Aging. Front Digit Health 2021; 2:545949. [PMID: 34713033 PMCID: PMC8521925 DOI: 10.3389/fdgth.2020.545949] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Accepted: 08/28/2020] [Indexed: 11/18/2022] Open
Abstract
In the context of the fourth revolution in healthcare technologies, leveraging monitoring and personalization across different domains becomes a key factor for providing useful services to maintain and promote well-being. This is even more crucial for older people, with aging being a complex multi-dimensional and multi-factorial process which can lead to frailty. The NESTORE project was recently funded by the EU Commission with the aim of supporting healthy older people to sustain their well-being and capacity to live independently. It is based on a multi-dimensional model of the healthy aging process that covers physical activity, nutrition, cognition, and social activity. NESTORE is based on the paradigm of the human-in-the-loop cyber-physical system that, exploiting the availability of Internet of Things technologies combined with analytics in the cloud, provides a virtual coaching system to support healthy aging. This work describes the design of the NESTORE methodology and its IoT architecture. We first model the end-user under several domains, then we present the NESTORE system that, analyzing relevant key-markers, provides coaching activities and personalized feedback to the user. Finally, we describe the validation strategy to assess the effectiveness of NESTORE as a coaching platform for healthy aging.
Collapse
Affiliation(s)
- Filippo Palumbo
- Institute of Information Science and Technologies of the National Research Council of Italy (ISTI-CNR), Pisa, Italy
| | - Antonino Crivello
- Institute of Information Science and Technologies of the National Research Council of Italy (ISTI-CNR), Pisa, Italy
| | - Francesco Furfari
- Institute of Information Science and Technologies of the National Research Council of Italy (ISTI-CNR), Pisa, Italy
| | - Michele Girolami
- Institute of Information Science and Technologies of the National Research Council of Italy (ISTI-CNR), Pisa, Italy
| | - Alfonso Mastropietro
- Institute of Biomedical Technologies of the National Research Council of Italy (ITB-CNR), Segrate, Italy
| | - Giorgio Manferdelli
- Institute of Biomedical Technologies of the National Research Council of Italy (ITB-CNR), Segrate, Italy
| | - Christina Röcke
- University Research Priority Program "Dynamics of Healthy Aging" of the University of Zurich, Zurich, Switzerland
| | - Sabrina Guye
- University Research Priority Program "Dynamics of Healthy Aging" of the University of Zurich, Zurich, Switzerland
| | | | - Maurizio Caon
- University of Applied Sciences and Arts of Western Switzerland HES-SO, Fribourg, Switzerland
| | - Francesco Carrino
- University of Applied Sciences and Arts of Western Switzerland HES-SO, Fribourg, Switzerland
| | - Omar Abou Khaled
- University of Applied Sciences and Arts of Western Switzerland HES-SO, Fribourg, Switzerland
| | - Elena Mugellini
- University of Applied Sciences and Arts of Western Switzerland HES-SO, Fribourg, Switzerland
| | | | | | | | | | - Silvia Orte
- eHealth Unit, Eurecat, Center Tecnològic de Catalunya, Barcelona, Spain
| | | | | | - Giovanna Rizzo
- Institute of Biomedical Technologies of the National Research Council of Italy (ITB-CNR), Segrate, Italy
| |
Collapse
|
113
|
Lo Presti D, Santucci F, Massaroni C, Formica D, Setola R, Schena E. A multi-point heart rate monitoring using a soft wearable system based on fiber optic technology. Sci Rep 2021; 11:21162. [PMID: 34707131 PMCID: PMC8551187 DOI: 10.1038/s41598-021-00574-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Accepted: 10/06/2021] [Indexed: 12/14/2022] Open
Abstract
Early diagnosis can be crucial to limit both the mortality and economic burden of cardiovascular diseases. Recent developments have focused on the continuous monitoring of cardiac activity for a prompt diagnosis. Nowadays, wearable devices are gaining broad interest for a continuous monitoring of the heart rate (HR). One of the most promising methods to estimate HR is the seismocardiography (SCG) which allows to record the thoracic vibrations with high non-invasiveness in out-of-laboratory settings. Despite significant progress on SCG, the current state-of-the-art lacks both information on standardized sensor positioning and optimization of wearables design. Here, we introduce a soft wearable system (SWS), whose novel design, based on a soft polymer matrix embedding an array of fiber Bragg gratings, provides a good adhesion to the body and enables the simultaneous recording of SCG signals from multiple measuring sites. The feasibility assessment on healthy volunteers revealed that the SWS is a suitable wearable solution for HR monitoring and its performance in HR estimation is strongly influenced by sensor positioning and improved by a multi-sensor configuration. These promising characteristics open the possibility of using the SWS in monitoring patients with cardiac pathologies in clinical (e.g., during cardiac magnetic resonance procedures) and everyday life settings.
Collapse
Affiliation(s)
- Daniela Lo Presti
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 00128, Rome, RM, Italy
| | - Francesca Santucci
- Departmental Faculty of Engineering, Unit of Automatic Control, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 00128, Rome, RM, Italy
| | - Carlo Massaroni
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 00128, Rome, RM, Italy
| | - Domenico Formica
- Unit of NEXT, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 00128, Rome, RM, Italy
| | - Roberto Setola
- Departmental Faculty of Engineering, Unit of Automatic Control, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 00128, Rome, RM, Italy
| | - Emiliano Schena
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21 00128, Rome, RM, Italy.
| |
Collapse
|
114
|
Miniaturized wireless, skin-integrated sensor networks for quantifying full-body movement behaviors and vital signs in infants. Proc Natl Acad Sci U S A 2021; 118:2104925118. [PMID: 34663725 PMCID: PMC8639372 DOI: 10.1073/pnas.2104925118] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/01/2021] [Indexed: 01/18/2023] Open
Abstract
Early detection of infant neuromotor pathologies is critical for timely therapeutic interventions that rely on early-life neuroplasticity. Traditional assessments rely on subjective expert evaluations or specialized medical facilities, making them challenging to scale in remote and/or resource-constrained settings. The results presented here aim to democratize these evaluations using wireless networks of miniaturized, skin-integrated sensors that digitize movement behaviors and vital signs of infants in a cost-effective manner. The resulting data yield full-body motion reconstructions in the form of deidentified infant avatars, along with a range of important cardiopulmonary information. This technology approach enables rapid, routine evaluations of infants at any age via an engineering platform that has potential for use in nearly any setting across developed and developing countries alike. Early identification of atypical infant movement behaviors consistent with underlying neuromotor pathologies can expedite timely enrollment in therapeutic interventions that exploit inherent neuroplasticity to promote recovery. Traditional neuromotor assessments rely on qualitative evaluations performed by specially trained personnel, mostly available in tertiary medical centers or specialized facilities. Such approaches are high in cost, require geographic proximity to advanced healthcare resources, and yield mostly qualitative insight. This paper introduces a simple, low-cost alternative in the form of a technology customized for quantitatively capturing continuous, full-body kinematics of infants during free living conditions at home or in clinical settings while simultaneously recording essential vital signs data. The system consists of a wireless network of small, flexible inertial sensors placed at strategic locations across the body and operated in a wide-bandwidth and time-synchronized fashion. The data serve as the basis for reconstructing three-dimensional motions in avatar form without the need for video recordings and associated privacy concerns, for remote visual assessments by experts. These quantitative measurements can also be presented in graphical format and analyzed with machine-learning techniques, with potential to automate and systematize traditional motor assessments. Clinical implementations with infants at low and at elevated risks for atypical neuromotor development illustrates application of this system in quantitative and semiquantitative assessments of patterns of gross motor skills, along with body temperature, heart rate, and respiratory rate, from long-term and follow-up measurements over a 3-mo period following birth. The engineering aspects are compatible for scaled deployment, with the potential to improve health outcomes for children worldwide via early, pragmatic detection methods.
Collapse
|
115
|
Herkert C, Migeotte PF, Hossein A, Spee RF, Kemps HMC. The kinocardiograph for assessment of changes in haemodynamic load in patients with chronic heart failure with reduced ejection fraction. ESC Heart Fail 2021; 8:4925-4932. [PMID: 34687162 PMCID: PMC8712789 DOI: 10.1002/ehf2.13522] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2021] [Revised: 06/14/2021] [Accepted: 07/05/2021] [Indexed: 01/15/2023] Open
Abstract
Aims The kinocardiograph (KCG) is an unobtrusive device, consisting of a chest sensor, which records local thoracic vibrations produced in result of cardiac contraction and ejection of blood into the great vessels [seismocardiography (SCG)], and a lower back sensor, which records micromovements of the body in reaction to blood flowing through the vasculature [ballistocardiography (BCG)]. SCG and BCG signals are translated to the integral of cardiac kinetic energy (iK) and cardiac maximum power (Pmax), which might be promising metrics for future telemonitoring purposes in heart failure (HF). As a first step of validation, this study aimed to determine whether iK and Pmax are responsive to exercise‐induced changes in the haemodynamic load of the heart in HF patients. Methods and results Fifteen patients with stable HF with reduced ejection fraction performed a submaximal exercise protocol. KCG and cardiac ultrasound measurements were obtained both at rest and at submaximal exercise. BCG iK over the cardiac cycle (CC) increased significantly (0.0026 ± 0.0017 to 0.0052 ± 0.0061 mJ.s.; P = 0.01) during exercise, in contrast to a non‐significant increase in SCG iK CC. BCG Pmax CC increased significantly (0.92 ± 0.89 to 2.03 ± 1.95 mJ/s; P = 0.02), in contrast to a non‐significant increase in SCG Pmax CC. When analysing the systolic phase of the CC, similar patterns were found. Cardiac output (CO) ratio (i.e. CO exercise/CO rest) showed a moderate, significant correlation with BCG Pmax CC ratio (r = +0.65; P = 0.008) and with SCG Pmax CC ratio (r = +0.54; P = 0.04). Conclusions iK and Pmax measured with the KCG, preferentially using BCG, are responsive to changes in the haemodynamic load of the heart in HF patients. The combination of the BCG and SCG sensor might be of added value to fully understand changes in haemodynamics and to discriminate between an HF patient and a healthy individual.
Collapse
Affiliation(s)
- Cyrille Herkert
- Department of Cardiology, Máxima Medical Centre, Dominee Theodor Fliednerstraat 1, Eindhoven, 5631 BM, The Netherlands
| | | | - Amin Hossein
- LPHYS, Université Libre de Bruxelles, Brussels, Belgium
| | - Rudolph Ferdinand Spee
- Department of Cardiology, Máxima Medical Centre, Dominee Theodor Fliednerstraat 1, Eindhoven, 5631 BM, The Netherlands
| | - Hareld Marijn Clemens Kemps
- Department of Cardiology, Máxima Medical Centre, Dominee Theodor Fliednerstraat 1, Eindhoven, 5631 BM, The Netherlands.,Department of Industrial Design, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
116
|
Yang C, Fan F, Aranoff N, Green P, Li Y, Liu C, Tavassolian N. An Open-Access Database for the Evaluation of Cardio-Mechanical Signals From Patients With Valvular Heart Diseases. Front Physiol 2021; 12:750221. [PMID: 34658932 PMCID: PMC8519311 DOI: 10.3389/fphys.2021.750221] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Accepted: 08/30/2021] [Indexed: 01/14/2023] Open
Abstract
This paper describes an open-access database for seismo-cardiogram (SCG) and gyro-cardiogram (GCG) signals. The archive comprises SCG and GCG recordings sourced from and processed at multiple sites worldwide, including Columbia University Medical Center and Stevens Institute of Technology in the United States, as well as Southeast University, Nanjing Medical University, and the first affiliated hospital of Nanjing Medical University in China. It includes electrocardiogram (ECG), SCG, and GCG recordings collected from 100 patients with various conditions of valvular heart diseases such as aortic and mitral stenosis. The recordings were collected from clinical environments with the same types of wearable sensor patch. Besides the raw recordings of ECG, SCG, and GCG signals, a set of hand-corrected fiducial point annotations is provided by manually checking the results of the annotated algorithm. The database also includes relevant echocardiogram parameters associated with each subject such as ejection fraction, valve area, and mean gradient pressure.
Collapse
Affiliation(s)
- Chenxi Yang
- School of Instrument Science and Engineering, Southeast University, Nanjing, China
| | - Foli Fan
- School of Instrument Science and Engineering, Southeast University, Nanjing, China
| | - Nicole Aranoff
- Mount Sinai Morningside Hospital, New York, NY, United States
| | - Philip Green
- Interventional Cardiology and Vascular Medicine, Sorin MedicalMount Sinai Morningside Hospital, New York, NY, United States
| | - Yuwen Li
- School of Instrument Science and Engineering, Southeast University, Nanjing, China
| | - Chengyu Liu
- School of Instrument Science and Engineering, Southeast University, Nanjing, China
| | - Negar Tavassolian
- Department of Electrical and Computer Engineering, Stevens Institute of Technology, Hoboken, NJ, United States
| |
Collapse
|
117
|
Zhang L, Cai P, Deng Y, Lin J, Wu M, Xiao Z, Chu Z, Shi Q, Ye F, Hu J, Yang C, Li P, Zhuang S, Wang B. Using a non-invasive multi-sensor device to evaluate left atrial pressure: an estimated filling pressure derived from ballistocardiography. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:1587. [PMID: 34790793 PMCID: PMC8576694 DOI: 10.21037/atm-21-5161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 10/20/2021] [Indexed: 02/05/2023]
Abstract
BACKGROUND Heart failure is a global health problem, and elevated left atrial pressure (LAP) is a precursor to identifying decompensated heart failure. At present, out-of-hospital monitoring of patients with heart failure is mostly based on the patient's symptoms and signs, and the use of non-invasive technology is scarce. In this study, a non-invasive ballistocardiography (BCG) device was used to collect thoracic vibration signals generated by heartbeat. We collected these signals from more than 1,000 adults, including those with different heart diseases, and used a sensor system and a composite index related to LAP recognition named the LAP-index, to analyze them. This study aimed to verify the reliability and accuracy of the LAP-index in identifying elevated LAP within heart failure patients. METHODS We prospectively included 158 patients with various extent of diastolic function, some of whom had various underlying diseases, and collected BCG and echocardiographic data using a cross-section methodology. The BCG signal was recorded from multiple optical fiber vibration sensors placed on the back of each patient. We adopted the 2016 ASE/EACVI echocardiography guideline as the standard for determining LAP level from echocardiography parameters. To evaluate the diagnostic efficacy of the LAP-index, we drew a receiver operating characteristic (ROC) curve and calculated the area under the ROC curve (AUC). RESULTS The LAP-index of the 158 patients ranged from 6 to 32. Of them, 39 were diagnosed as high LAP by echocardiography, and 119 cases had normal or slightly elevated LAP. Comparison of the LAP-index results and echocardiographic results revealed the ROC c-statistic of the LAP-index for identifying high LAP was 0.86 (95% CI: 0.79-0.93; P<0.0001). When the LAP-index was at the best cut-off value of 15.5, the positive agreement rate between it and echocardiography LAP was 0.85, the negative agreement rate was 0.80, and the overall agreement rate was 0.81. CONCLUSIONS The sensor system and the LAP-index, a composite index derived from BCG, have high reliability and accuracy in identifying elevated LAP, which provides a novel possibility for the non-invasive detection of hemodynamic congestion in heart failure patients.
Collapse
Affiliation(s)
- Li Zhang
- Department of Cardiology, the First Affiliated Hospital of Shantou University Medical College, Shantou, China
- Clinical Research Center, the First Affiliated Hospital of Shantou University Medical College, Shantou, China
| | - Peiwei Cai
- Ultrasound Division, the First Affiliated Hospital of Shantou University Medical College, Shantou, China
| | - Yinlong Deng
- Department of Cardiology, the First Affiliated Hospital of Shantou University Medical College, Shantou, China
| | - Jiumin Lin
- Department of Hepatology and Infectious Diseases, the Second Affiliated Hospital of Shantou University Medical College, Shantou, China
| | - Muli Wu
- Department of Cardiology, the First Affiliated Hospital of Shantou University Medical College, Shantou, China
| | - Zhongbo Xiao
- Department of Cardiology, the First Affiliated Hospital of Shantou University Medical College, Shantou, China
| | | | | | - Fei Ye
- DARMA Lab, Shenzhen, China
| | | | | | - Pengyang Li
- Department of Medicine, Saint Vincent Hospital, Worcester, MA, USA
| | | | - Bin Wang
- Department of Cardiology, the First Affiliated Hospital of Shantou University Medical College, Shantou, China
- Clinical Research Center, the First Affiliated Hospital of Shantou University Medical College, Shantou, China
| |
Collapse
|
118
|
The Latest Progress and Development Trend in the Research of Ballistocardiography (BCG) and Seismocardiogram (SCG) in the Field of Health Care. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11198896] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The current status of the research of Ballistocardiography (BCG) and Seismocardiogram (SCG) in the field of medical treatment, health care and nursing was analyzed systematically, and the important direction in the research was explored, to provide reference for the relevant researches. This study, based on two large databases, CNKI and PubMed, used the bibliometric analysis method to review the existing documents in the past 20 years, and made analyses on the literature of BCG and SCG for their annual changes, main countries/regions, types of research, frequently-used subject words, and important research subjects. The results show that the developed countries have taken a leading position in the researches in this field, and have made breakthroughs in some subjects, but their research results have been mainly gained in the area of research and development of the technologies, and very few have been actually industrialized into commodities. This means that in the future the researchers should focus on the transformation of BCG and SCG technologies into commercialized products, and set up quantitative health assessment models, so as to become the daily tools for people to monitor their health status and manage their own health, and as the main approaches of improving the quality of life and preventing diseases for individuals.
Collapse
|
119
|
Shandhi MMH, Goldsack JC, Ryan K, Bennion A, Kotla AV, Feng A, Jiang Y, Wang WK, Hurst T, Patena J, Carini S, Chung J, Dunn J. Recent Academic Research on Clinically Relevant Digital Measures: Systematic Review. J Med Internet Res 2021; 23:e29875. [PMID: 34524089 PMCID: PMC8482196 DOI: 10.2196/29875] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 07/02/2021] [Accepted: 08/12/2021] [Indexed: 01/16/2023] Open
Abstract
Background Digital clinical measures collected via various digital sensing technologies such as smartphones, smartwatches, wearables, ingestibles, and implantables are increasingly used by individuals and clinicians to capture health outcomes or behavioral and physiological characteristics of individuals. Although academia is taking an active role in evaluating digital sensing products, academic contributions to advancing the safe, effective, ethical, and equitable use of digital clinical measures are poorly characterized. Objective We performed a systematic review to characterize the nature of academic research on digital clinical measures and to compare and contrast the types of sensors used and the sources of funding support for specific subareas of this research. Methods We conducted a PubMed search using a range of search terms to retrieve peer-reviewed articles reporting US-led academic research on digital clinical measures between January 2019 and February 2021. We screened each publication against specific inclusion and exclusion criteria. We then identified and categorized research studies based on the types of academic research, sensors used, and funding sources. Finally, we compared and contrasted the funding support for these specific subareas of research and sensor types. Results The search retrieved 4240 articles of interest. Following the screening, 295 articles remained for data extraction and categorization. The top five research subareas included operations research (research analysis; n=225, 76%), analytical validation (n=173, 59%), usability and utility (data visualization; n=123, 42%), verification (n=93, 32%), and clinical validation (n=83, 28%). The three most underrepresented areas of research into digital clinical measures were ethics (n=0, 0%), security (n=1, 0.5%), and data rights and governance (n=1, 0.5%). Movement and activity trackers were the most commonly studied sensor type, and physiological (mechanical) sensors were the least frequently studied. We found that government agencies are providing the most funding for research on digital clinical measures (n=192, 65%), followed by independent foundations (n=109, 37%) and industries (n=56, 19%), with the remaining 12% (n=36) of these studies completely unfunded. Conclusions Specific subareas of academic research related to digital clinical measures are not keeping pace with the rapid expansion and adoption of digital sensing products. An integrated and coordinated effort is required across academia, academic partners, and academic funders to establish the field of digital clinical measures as an evidence-based field worthy of our trust.
Collapse
Affiliation(s)
| | | | - Kyle Ryan
- Big Ideas Lab, Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Alexandra Bennion
- Big Ideas Lab, Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Aditya V Kotla
- Big Ideas Lab, Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Alina Feng
- Big Ideas Lab, Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Yihang Jiang
- Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Will Ke Wang
- Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Tina Hurst
- Activinsights Ltd, Cambridgeshire, United Kingdom
| | - John Patena
- Brown-Lifespan Center for Digital Health, Brown University, Providence, RI, United States
| | - Simona Carini
- Division of General Internal Medicine, University of California, San Francisco, CA, United States
| | - Jeanne Chung
- Digital Medicine Society, Boston, MA, United States
| | - Jessilyn Dunn
- Department of Biomedical Engineering, Duke University, Durham, NC, United States.,Department of Biostatistics & Bioinformatics, Duke University, Durham, NC, United States
| |
Collapse
|
120
|
A Comprehensive Review on Seismocardiogram: Current Advancements on Acquisition, Annotation, and Applications. MATHEMATICS 2021. [DOI: 10.3390/math9182243] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
In recent years, cardiovascular diseases are on the rise, and they entail enormous health burdens on global economies. Cardiac vibrations yield a wide and rich spectrum of essential information regarding the functioning of the heart, and thus it is necessary to take advantage of this data to better monitor cardiac health by way of prevention in early stages. Specifically, seismocardiography (SCG) is a noninvasive technique that can record cardiac vibrations by using new cutting-edge devices as accelerometers. Therefore, providing new and reliable data regarding advancements in the field of SCG, i.e., new devices and tools, is necessary to outperform the current understanding of the State-of-the-Art (SoTA). This paper reviews the SoTA on SCG and concentrates on three critical aspects of the SCG approach, i.e., on the acquisition, annotation, and its current applications. Moreover, this comprehensive overview also presents a detailed summary of recent advancements in SCG, such as the adoption of new techniques based on the artificial intelligence field, e.g., machine learning, deep learning, artificial neural networks, and fuzzy logic. Finally, a discussion on the open issues and future investigations regarding the topic is included.
Collapse
|
121
|
Advanced Fusion and Empirical Mode Decomposition-Based Filtering Methods for Breathing Rate Estimation from Seismocardiogram Signals. INFORMATION 2021. [DOI: 10.3390/info12090368] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Breathing Rate (BR), an important deterioration indicator, has been widely neglected in hospitals due to the requirement of invasive procedures and the need for skilled nurses to be measured. On the other hand, biomedical signals such as Seismocardiography (SCG), which measures heart vibrations transmitted to the chest-wall, can be used as a non-invasive technique to estimate the BR. This makes SCG signals a highly appealing way for estimating the BR. As such, this work proposes three novel methods for extracting the BR from SCG signals. The first method is based on extracting respiration-dependent features such as the fundamental heart sound components, S1 and S2 from the SCG signal. The second novel method investigates for the first time the use of data driven methods such as the Empirical Mode Decomposition (EMD) method to identify the respiratory component from an SCG signal. Finally, the third advanced method is based on fusing frequency information from the respiration signals that result from the aforementioned proposed methods and other standard methods. The developed methods in this paper are then evaluated on adult recordings from the combined measurement of ECG, the Breathing and Seismocardiograms database. Both fusion and EMD filter-based methods outperformed the individual methods, giving a mean absolute error of 1.5 breaths per minute, using a one-minute window of data.
Collapse
|
122
|
Jiao C, Chen C, Gou S, Hai D, Su BY, Skubic M, Jiao L, Zare A, Ho KC. Non-Invasive Heart Rate Estimation From Ballistocardiograms Using Bidirectional LSTM Regression. IEEE J Biomed Health Inform 2021; 25:3396-3407. [PMID: 33945489 DOI: 10.1109/jbhi.2021.3077002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Non-invasive heart rate estimation is of great importance in daily monitoring of cardiovascular diseases. In this paper, a bidirectional long short term memory (bi-LSTM) regression network is developed for non-invasive heart rate estimation from the ballistocardiograms (BCG) signals. The proposed deep regression model provides an effective solution to the existing challenges in BCG heart rate estimation, such as the mismatch between the BCG signals and ground-truth reference, multi-sensor fusion and effective time series feature learning. Allowing label uncertainty in the estimation can reduce the manual cost of data annotation while further improving the heart rate estimation performance. Compared with the state-of-the-art BCG heart rate estimation methods, the strong fitting and generalization ability of the proposed deep regression model maintains better robustness to noise (e.g., sensor noise) and perturbations (e.g., body movements) in the BCG signals and provides a more reliable solution for long term heart rate monitoring.
Collapse
|
123
|
Jung H, Kimball JP, Receveur T, Agdeppa ED, Inan OT. Accurate Ballistocardiogram Based Heart Rate Estimation Using an Array of Load Cells in a Hospital Bed. IEEE J Biomed Health Inform 2021; 25:3373-3383. [PMID: 33729962 DOI: 10.1109/jbhi.2021.3066885] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The ballistocardiogram (BCG), a cardiac vibration signal, has been widely investigated for continuous monitoring of heart rate (HR). Among BCG sensing modalities, a hospital bed with multi-channel load-cells could provide robust HR estimation in hospital setups. In this work, we present a novel array processing technique to improve the existing HR estimation algorithm by optimizing the fusion of information from multiple channels. The array processing includes a Gaussian curve to weight the joint probability according to the reference value obtained from the previous inter-beat-interval (IBI) estimations. Additionally, the probability density functions were selected and combined according to their reliability measured by q-values. We demonstrate that this array processing significantly reduces the HR estimation error compared to state-of-the-art multi-channel heartbeat detection algorithms in the existing literature. In the best case, the average mean absolute error (MAE) of 1.76 bpm in the supine position was achieved compared to 2.68 bpm and 1.91 bpm for two state-of-the-art methods from the existing literature. Moreover, the lowest error was found in the supine posture (1.76 bpm) and the highest in the lateral posture (3.03 bpm), thus elucidating the postural effects on HR estimation. The IBI estimation capability was also evaluated, with a MAE of 16.66 ms and confidence interval (95%) of 38.98 ms. The results demonstrate that improved HR estimation can be obtained for a bed-based BCG system with the multi-channel data acquisition and processing approach described in this work.
Collapse
|
124
|
Kimball JP, Zia JS, An S, Rolfes C, Hahn JO, Sawka MN, Inan OT. Unifying the Estimation of Blood Volume Decompensation Status in a Porcine Model of Relative and Absolute Hypovolemia Via Wearable Sensing. IEEE J Biomed Health Inform 2021; 25:3351-3360. [PMID: 33760744 DOI: 10.1109/jbhi.2021.3068619] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Hypovolemia remains the leading cause of preventable death in trauma cases. Recent research has demonstrated that using noninvasive continuous waveforms rather than traditional vital signs improves accuracy in early detection of hypovolemia to assist in triage and resuscitation. This work evaluates random forest models trained on different subsets of data from a pig model (n = 6) of absolute (bleeding) and relative (nitroglycerin-induced vasodilation) progressive hypovolemia (to 20% decrease in mean arterial pressure) and resuscitation. Features for the models were derived from a multi-modal set of wearable sensors, comprised of the electrocardiogram (ECG), seismocardiogram (SCG) and reflective photoplethysmogram (RPPG) and were normalized to each subject.s baseline. The median RMSE between predicted and actual percent progression towards cardiovascular decompensation for the best model was 30.5% during the relative period, 16.8% during absolute and 22.1% during resuscitation. The least squares best fit line over the mean aggregated predictions had a slope of 0.65 and intercept of 12.3, with an R2 value of 0.93. When transitioned to a binary classification problem to identify decompensation, this model achieved an AUROC of 0.80. This study: a) developed a global model incorporating ECG, SCG and RPPG features for estimating individual-specific decompensation from progressive relative and absolute hypovolemia and resuscitation; b) demonstrated SCG as the most important modality to predict decompensation; c) demonstrated efficacy of random forest models trained on different data subsets; and d) demonstrated adding training data from two discrete forms of hypovolemia increases prediction accuracy for the other form of hypovolemia and resuscitation.
Collapse
|
125
|
Zschocke J, Leube J, Glos M, Semyachkina-Glushkovskaya O, Penzel T, Bartsch R, Kantelhardt J. Reconstruction of Pulse Wave and Respiration from Wrist Accelerometer During Sleep. IEEE Trans Biomed Eng 2021; 69:830-839. [PMID: 34437055 DOI: 10.1109/tbme.2021.3107978] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE Nocturnal recordings of heart rate and respiratory rate usually require several separate sensors or electrodes attached to different body parts -- a disadvantage for at-home screening tests and for large cohort studies. In this paper, we demonstrate that a state-of-the-art accelerometer placed at subjects' wrists can be used to derive reliable signal reconstructions of heartbeat (pulse wave intervals) and respiration during sleep. METHODS Based on 226 full-night recordings, we evaluate the performance of our signal reconstruction methodology with respect to polysomnography. We use a phase synchronization analysis metrics that considers individual heartbeats or breaths. RESULTS The quantitative comparison reveals that pulse-wave signal reconstructions are generally better than respiratory signal reconstructions. The best quality is achieved during deep sleep, followed by light sleep N2 and REM sleep. In addition, a suggested internal evaluation of multiple derived reconstructions can be used to identify time periods with highly reliable signals, particularly for pulse waves. Furthermore, we find that pulse-wave reconstructions are hardly affected by apnea and hypopnea events. CONCLUSION During sleep, pulse wave and respiration signals can simultaneously be reconstructed from the same accelerometer recording at the wrist without the need for additional sensors. Reliability can be increased by internal evaluation if the reconstructed signals are not needed for the whole sleep duration. SIGNIFICANCE The presented methodology can help to determine sleep characteristics and improve diagnostics and treatment of sleep disorders in the subjects' normal sleep environment.
Collapse
|
126
|
Frequency-Modulated Continuous Wave Radar Respiratory Pattern Detection Technology Based on Multifeature. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:9376662. [PMID: 34413970 PMCID: PMC8370824 DOI: 10.1155/2021/9376662] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Revised: 07/08/2021] [Accepted: 07/30/2021] [Indexed: 11/18/2022]
Abstract
Respiratory diseases including apnea are often accompanied by abnormal respiratory depth, frequency, and rhythm. If different abnormal respiratory patterns can be detected and recorded, with their depth, frequency, and rhythm analyzed, the detection and diagnosis of respiratory diseases can be achieved. High-frequency millimeter-wave radar (76–81 GHz) has low environmental impact, high accuracy, and small volume, which is more suitable for respiratory signal detection and recognition compared with other contact equipment. In this paper, the experimental platform of frequency-modulated continuous wave (FMCW) radar was built at first, realizing the noncontact measurement of vital signs. Secondly, the energy intensity and threshold of respiration signal during each period were calculated by using the rectangular window, and the accurate judgment of apnea was realized via numerical comparison. Thirdly, the features of respiratory and heart rate signals, the number of peaks and valleys, the difference between peaks and valleys, the average and the standard deviation of normalized short-term energy, and the average and the standard deviation and the minimum of instantaneous frequency, were extracted and analyzed. Finally, support vector machine (SVM) and K-nearest neighbor (KNN) were used to classify the extracted features, and the accuracy was 98.25% and 88.75%, respectively. The classification and recognition of respiratory patterns have been successfully realized.
Collapse
|
127
|
Martinek R, Ladrova M, Sidikova M, Jaros R, Behbehani K, Kahankova R, Kawala-Sterniuk A. Advanced Bioelectrical Signal Processing Methods: Past, Present and Future Approach-Part I: Cardiac Signals. SENSORS (BASEL, SWITZERLAND) 2021; 21:5186. [PMID: 34372424 PMCID: PMC8346990 DOI: 10.3390/s21155186] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 07/23/2021] [Accepted: 07/26/2021] [Indexed: 11/30/2022]
Abstract
Advanced signal processing methods are one of the fastest developing scientific and technical areas of biomedical engineering with increasing usage in current clinical practice. This paper presents an extensive literature review of the methods for the digital signal processing of cardiac bioelectrical signals that are commonly applied in today's clinical practice. This work covers the definition of bioelectrical signals. It also covers to the extreme extent of classical and advanced approaches to the alleviation of noise contamination such as digital adaptive and non-adaptive filtering, signal decomposition methods based on blind source separation and wavelet transform.
Collapse
Affiliation(s)
- Radek Martinek
- FEECS, Department of Cybernetics and Biomedical Engineering, VSB-Technical University Ostrava, 708 00 Ostrava, Czech Republic; (M.L.); (M.S.); (R.J.); (R.K.)
| | - Martina Ladrova
- FEECS, Department of Cybernetics and Biomedical Engineering, VSB-Technical University Ostrava, 708 00 Ostrava, Czech Republic; (M.L.); (M.S.); (R.J.); (R.K.)
| | - Michaela Sidikova
- FEECS, Department of Cybernetics and Biomedical Engineering, VSB-Technical University Ostrava, 708 00 Ostrava, Czech Republic; (M.L.); (M.S.); (R.J.); (R.K.)
| | - Rene Jaros
- FEECS, Department of Cybernetics and Biomedical Engineering, VSB-Technical University Ostrava, 708 00 Ostrava, Czech Republic; (M.L.); (M.S.); (R.J.); (R.K.)
| | - Khosrow Behbehani
- College of Engineering, The University of Texas in Arlington, Arlington, TX 76019, USA;
| | - Radana Kahankova
- FEECS, Department of Cybernetics and Biomedical Engineering, VSB-Technical University Ostrava, 708 00 Ostrava, Czech Republic; (M.L.); (M.S.); (R.J.); (R.K.)
| | - Aleksandra Kawala-Sterniuk
- Faculty of Electrical Engineering, Automatic Control and Informatics, Opole University of Technology, 45-758 Opole, Poland
| |
Collapse
|
128
|
Landry C, Hedge ET, Hughson RL, Peterson SD, Arami A. Accurate Blood Pressure Estimation During Activities of Daily Living: A Wearable Cuffless Solution. IEEE J Biomed Health Inform 2021; 25:2510-2520. [PMID: 33497346 DOI: 10.1109/jbhi.2021.3054597] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The objective is to develop a cuffless method that accurately estimates blood pressure (BP) during activities of daily living. User-specific nonlinear autoregressive models with exogenous inputs (NARX) are implemented using artificial neural networks to estimate the BP waveforms from electrocardiography and photoplethysmography signals. To broaden the range of BP in the training data, subjects followed a short procedure consisting of sitting, standing, walking, Valsalva maneuvers, and static handgrip exercises. The procedure was performed before and after a six-hour testing phase wherein five participants went about their normal daily living activities. Data were further collected at a four-month time point for two participants and again at six months for one of the two. The performance of three different NARX models was compared with three pulse arrival time (PAT) models. The NARX models demonstrate superior accuracy and correlation with "ground truth" systolic and diastolic BP measures compared to the PAT models and a clear advantage in estimating the large range of BP. Preliminary results show that the NARX models can accurately estimate BP even months apart from the training. Preliminary testing suggests that it is robust against variabilities due to sensor placement. This establishes a method for cuffless BP estimation during activities of daily living that can be used for continuous monitoring and acute hypotension and hypertension detection.
Collapse
|
129
|
Choudhary T, Das M, Sharma L, Bhuyan M. Analyzing seismocardiographic approach for heart rate variability measurement. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102793] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
130
|
Lin DJ, Kimball JP, Zia J, Ganti VG, Inan OT. Reducing the Impact of External Vibrations on Fiducial Point Detection in Seismocardiogram Signals. IEEE Trans Biomed Eng 2021; 69:176-185. [PMID: 34161234 DOI: 10.1109/tbme.2021.3090376] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE Wearable systems that enable continuous non-invasive monitoring of hemodynamic parameters can aid in cardiac health evaluation in non-hospital settings. The seismocardiogram (SCG) is a non-invasively acquired cardiovascular biosignal for which timings of fiducial points, like aortic valve opening (AO) and aortic valve closing (AC), can enable estimation of key hemodynamic parameters. However, SCG is susceptible to motion artifacts, making accurate estimation of these points difficult when corrupted by high-g or in-band vibration artifacts. In this paper, a novel denoising pipeline is proposed that removes vehicle-vibration artifacts from corrupted SCG beats for accurate fiducial point detection. METHODS The noisy SCG signal is decomposed with ensemble empirical mode decomposition (EEMD). Corrupted segments of the decomposed signal are then identified and removed using the quasi-periodicity of the SCG. Signal quality assessment of the reconstructed SCG beats then removes unreliable beats before feature extraction. The overall approach is validated on simulated vehicle-corrupted SCG generated by adding real subway collected vibration signals onto clean SCG. RESULTS SNR increased by 8.1dB in the AO complex and 11.5dB in the AC complex of the SCG signal. Hemodynamic timing estimation errors reduced by 16.5\% for pre-ejection period (PEP), 67.2\% for left ventricular ejection time (LVET), and 57.7\% for PEP/LVET---a feature previously determined in prior work to be of great importance for assessing blood volume status during hemorrhage. CONCLUSION These findings suggest that usable SCG signals can be recovered from vehicle-corrupted SCG signals using the presented denoising framework, allowing for accurate hemodynamic timing estimation. SIGNIFICANCE Reliable hemodynamic estimates from vehicle-corrupted SCG signals will enable the adoption of the SCG in outside-of-hospital settings.
Collapse
|
131
|
Recent Research for Unobtrusive Atrial Fibrillation Detection Methods Based on Cardiac Dynamics Signals: A Survey. SENSORS 2021; 21:s21113814. [PMID: 34072986 PMCID: PMC8199222 DOI: 10.3390/s21113814] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 05/20/2021] [Accepted: 05/26/2021] [Indexed: 11/16/2022]
Abstract
Atrial fibrillation (AF) is the most common cardiac arrhythmia. It tends to cause multiple cardiac conditions, such as cerebral artery blockage, stroke, and heart failure. The morbidity and mortality of AF have been progressively increasing over the past few decades, which has raised widespread concern about unobtrusive AF detection in routine life. The up-to-date non-invasive AF detection methods include electrocardiogram (ECG) signals and cardiac dynamics signals, such as the ballistocardiogram (BCG) signal, the seismocardiogram (SCG) signal and the photoplethysmogram (PPG) signal. Cardiac dynamics signals can be collected by cushions, mattresses, fabrics, or even cameras, which is more suitable for long-term monitoring. Therefore, methods for AF detection by cardiac dynamics signals bring about extensive attention for recent research. This paper reviews the current unobtrusive AF detection methods based on the three cardiac dynamics signals, summarized as data acquisition and preprocessing, feature extraction and selection, classification and diagnosis. In addition, the drawbacks and limitations of the existing methods are analyzed, and the challenges in future work are discussed.
Collapse
|
132
|
Wan R, Huang Y, Wu X. Detection of Ventricular Fibrillation Based on Ballistocardiography by Constructing an Effective Feature Set. SENSORS (BASEL, SWITZERLAND) 2021; 21:3524. [PMID: 34069374 PMCID: PMC8158750 DOI: 10.3390/s21103524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Revised: 05/15/2021] [Accepted: 05/17/2021] [Indexed: 11/17/2022]
Abstract
Ventricular fibrillation (VF) is a type of fatal arrhythmia that can cause sudden death within minutes. The study of a VF detection algorithm has important clinical significance. This study aimed to develop an algorithm for the automatic detection of VF based on the acquisition of cardiac mechanical activity-related signals, namely ballistocardiography (BCG), by non-contact sensors. BCG signals, including VF, sinus rhythm, and motion artifacts, were collected through electric defibrillation experiments in pigs. Through autocorrelation and S transform, the time-frequency graph with obvious information of cardiac rhythmic activity was obtained, and a feature set of 13 elements was constructed for each 7 s segment after statistical analysis and hierarchical clustering. Then, the random forest classifier was used to classify VF and non-VF, and two paradigms of intra-patient and inter-patient were used to evaluate the performance. The results showed that the sensitivity and specificity were 0.965 and 0.958 under 10-fold cross-validation, and they were 0.947 and 0.946 under leave-one-subject-out cross-validation. In conclusion, the proposed algorithm combining feature extraction and machine learning can effectively detect VF in BCG, laying a foundation for the development of long-term self-cardiac monitoring at home and a VF real-time detection and alarm system.
Collapse
Affiliation(s)
- Rongru Wan
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai 200433, China; (R.W.); (Y.H.)
| | - Yanqi Huang
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai 200433, China; (R.W.); (Y.H.)
| | - Xiaomei Wu
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai 200433, China; (R.W.); (Y.H.)
- Key Laboratory of Medical Imaging Computing and Computer Assisted Intervention (MICCAI) of Shanghai, Fudan University, Shanghai 200032, China
- Shanghai Engineering Research Center of Assistive Devices, Shanghai 200093, China
| |
Collapse
|
133
|
Gardner M, Randhawa S, Malouf G, Reynolds K. A Wearable Ballistocardiography Device for Estimating Heart Rate During Positive Airway Pressure Therapy: Investigational Study Among the General Population. JMIR Cardio 2021; 5:e26259. [PMID: 33949952 PMCID: PMC8411434 DOI: 10.2196/26259] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2020] [Revised: 03/31/2021] [Accepted: 04/03/2021] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Obstructive sleep apnea (OSA) is a condition in which a person's airway is obstructed during sleep, thus disturbing their sleep. People with OSA are at a higher risk of developing heart problems. OSA is commonly treated with a positive airway pressure (PAP) therapy device, which is used during sleep. The PAP therapy setup provides a good opportunity to monitor the heart health of people with OSA, but no simple, low-cost method is available for the PAP therapy device to monitor heart rate (HR). OBJECTIVE This study aims to develop a simple, low-cost device to monitor the HR of people with OSA during PAP therapy. This device was then tested on a small group of participants to investigate the feasibility of the device. METHODS A low-cost and simple device to monitor HR was created by attaching a gyroscope to a PAP mask, thus integrating HR monitoring into PAP therapy. The gyroscope signals were then analyzed to detect heartbeats, and a Kalman filter was used to produce a more accurate and consistent HR signal. In this study, 19 participants wore the modified PAP mask while the mask was connected to a PAP device. Participants lay in 3 common sleeping positions and then underwent 2 different PAP therapy modes to determine if these affected the accuracy of the HR estimation. RESULTS Before the PAP device was turned on, the median HR error was <5 beats per minute, although the HR estimation error increased when participants lay on their side compared with when participants lay on their back. Using the different PAP therapy modes did not significantly increase the HR error. CONCLUSIONS These results show that monitoring HR from gyroscope signals in a PAP mask is possible during PAP therapy for different sleeping positions and PAP therapy modes, suggesting that long-term HR monitoring of OSA during PAP therapy may be possible.
Collapse
Affiliation(s)
- Mark Gardner
- Medical Device Research Institute, Flinders University, Clovelly Park, Australia
- ACRF Image X Institute, Eveleigh, Australia
| | - Sharmil Randhawa
- Medical Device Research Institute, Flinders University, Clovelly Park, Australia
| | - Gordon Malouf
- ResMed Asia Operations Ptd Ltd, Singapore, Singapore
| | - Karen Reynolds
- Medical Device Research Institute, Flinders University, Clovelly Park, Australia
| |
Collapse
|
134
|
Semiz B, Carek AM, Johnson JC, Ahmad S, Heller JA, Vicente FG, Caron S, Hogue CW, Etemadi M, Inan OT. Non-Invasive Wearable Patch Utilizing Seismocardiography for Peri-Operative Use in Surgical Patients. IEEE J Biomed Health Inform 2021; 25:1572-1582. [PMID: 33090962 PMCID: PMC8189504 DOI: 10.1109/jbhi.2020.3032938] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVE Optimizing peri-operative fluid management has been shown to improve patient outcomes and the use of stroke volume (SV) measurement has become an accepted tool to guide fluid therapy. The Transesophageal Doppler (TED) is a validated, minimally invasive device that allows clinical assessment of SV. Unfortunately, the use of the TED is restricted to the intra-operative setting in anesthetized patients and requires constant supervision and periodic adjustment for accurate signal quality. However, post-operative fluid management is also vital for improved outcomes. Currently, there is no device regularly used in clinics that can track patient's SV continuously and non-invasively both during and after surgery. METHODS In this paper, we propose the use of a wearable patch mounted on the mid-sternum, which captures the seismocardiogram (SCG) and electrocardiogram (ECG) signals continuously to predict SV in patients undergoing major surgery. In a study of 12 patients, hemodynamic data was recorded simultaneously using the TED and wearable patch. Signal processing and regression techniques were used to derive SV from the signals (SCG and ECG) captured by the wearable patch and compare it to values obtained by the TED. RESULTS The results showed that the combination of SCG and ECG contains substantial information regarding SV, resulting in a correlation and median absolute error between the predicted and reference SV values of 0.81 and 7.56 mL, respectively. SIGNIFICANCE This work shows promise for the proposed wearable-based methodology to be used as an alternative to TED for continuous patient monitoring and guiding peri-operative fluid management.
Collapse
|
135
|
A Wearable System with Embedded Conductive Textiles and an IMU for Unobtrusive Cardio-Respiratory Monitoring. SENSORS 2021; 21:s21093018. [PMID: 33923071 PMCID: PMC8123320 DOI: 10.3390/s21093018] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 04/19/2021] [Accepted: 04/21/2021] [Indexed: 02/05/2023]
Abstract
The continuous and simultaneous monitoring of physiological parameters represents a key aspect in clinical environments, remote monitoring and occupational settings. In this regard, respiratory rate (RR) and heart rate (HR) are correlated with several physiological and pathological conditions of the patients/workers, and with environmental stressors. In this work, we present and validate a wearable device for the continuous monitoring of such parameters. The proposed system embeds four conductive sensors located on the user's chest which allow retrieving the breathing activity through their deformation induced during cyclic expansion and contraction of the rib cage. For monitoring HR we used an embedded IMU located on the left side of the chest wall. We compared the proposed device in terms of estimating HR and RR against a reference system in three scenarios: sitting, standing and supine. The proposed system reliably estimated both RR and HR, showing low error averaged along subjects in all scenarios. This is the first study focused on the feasibility assessment of a wearable system based on a multi-sensor configuration (i.e., conductive sensors and IMU) for RR and HR monitoring. The promising results encourage the application of this approach in clinical and occupational settings.
Collapse
|
136
|
Quesada O, Shandhi MMH, Beach S, Dowling S, Tandon D, Heller J, Etemadi M, Roy S, Gonzalez Velez JM, Inan OT, Klein L. Use of Ballistocardiography to Monitor Cardiovascular Hemodynamics in Preeclampsia. WOMEN'S HEALTH REPORTS 2021; 2:97-105. [PMID: 33937907 PMCID: PMC8080913 DOI: 10.1089/whr.2020.0127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Accepted: 03/08/2021] [Indexed: 11/29/2022]
Abstract
Objective: Pregnancy requires a complex physiological adaptation of the maternal cardiovascular system, which is disrupted in women with pregnancies complicated by preeclampsia, putting them at higher risk of future cardiovascular events. The measurement of body movements in response to cardiac ejection via ballistocardiogram (BCG) can be used to assess cardiovascular hemodynamics noninvasively in women with preeclampsia. Methods: Using a previously validated, modified weighing scale for assessment of cardiovascular hemodynamics through measurement of BCG and electrocardiogram (ECG) signals, we collected serial measurements throughout pregnancy and postpartum and analyzed data in 30 women with preeclampsia and 23 normotensive controls. Using BCG and ECG signals, we extracted measures of cardiac output, J-wave amplitude × heart rate (J-amp × HR). Mixed-effect models with repeated measures were used to compare J-amp × HRs between groups at different time points in pregnancy and postpartum. Results: In normotensive controls, the J-amp × HR was significantly lower early postpartum (E-PP) compared with the second trimester (T2; p = 0.016) and third trimester (T3; p = 0.001). Women with preeclampsia had a significantly lower J-amp × HR compared with normotensive controls during the first trimester (T1; p = 0.026). In the preeclampsia group, there was a trend toward an increase in J-amp × HR from T1 to T2 and then a drop in J-amp × HR at T3 and further drop at E-PP. Conclusions: We observe cardiac hemodynamic changes consistent with those reported using well-validated tools. In pregnancies complicated by preeclampsia, the maximal force of contraction is lower, suggesting lower cardiac output and a trend in hemodynamics consistent with the hyperdynamic disease model of preeclampsia.
Collapse
Affiliation(s)
- Odayme Quesada
- Women's Heart Center, The Christ Hospital Heart Vascular and Lung Institute, Cincinnati, Ohio, USA.,Barbra Streisand Women's Heart Center, Cedars-Sinai Smidt Heart Institute, Los Angeles, California, USA
| | - Md Mobashir Hasan Shandhi
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Shire Beach
- Division of Cardiology, Department of Internal Medicine, University of California San Francisco, San Francisco, California, USA
| | - Sean Dowling
- Division of Cardiology, Department of Internal Medicine, University of California San Francisco, San Francisco, California, USA
| | - Damini Tandon
- Division of Cardiology, Department of Internal Medicine, University of California San Francisco, San Francisco, California, USA
| | - James Heller
- Department of Obstetrics and Gynecology, University of California San Francisco, San Francisco, California, USA
| | - Mozziyar Etemadi
- Department of Obstetrics and Gynecology, University of California San Francisco, San Francisco, California, USA
| | - Shuvo Roy
- Division of Cardiology, Department of Internal Medicine, University of California San Francisco, San Francisco, California, USA
| | | | - Omer T Inan
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Liviu Klein
- Division of Cardiology, Department of Internal Medicine, University of California San Francisco, San Francisco, California, USA
| |
Collapse
|
137
|
Rahmani MH, Berkvens R, Weyn M. Chest-Worn Inertial Sensors: A Survey of Applications and Methods. SENSORS (BASEL, SWITZERLAND) 2021; 21:2875. [PMID: 33921900 PMCID: PMC8074221 DOI: 10.3390/s21082875] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 04/14/2021] [Accepted: 04/14/2021] [Indexed: 01/16/2023]
Abstract
Inertial Measurement Units (IMUs) are frequently implemented in wearable devices. Thanks to advances in signal processing and machine learning, applications of IMUs are not limited to those explicitly addressing body movements such as Activity Recognition (AR). On the other hand, wearing IMUs on the chest offers a few advantages over other body positions. AR and posture analysis, cardiopulmonary parameters estimation, voice and swallowing activity detection and other measurements can be approached through chest-worn inertial sensors. This survey tries to introduce the applications that come with the chest-worn IMUs and summarizes the existing methods, current challenges and future directions associated with them. In this regard, this paper references a total number of 57 relevant studies from the last 10 years and categorizes them into seven application areas. We discuss the inertial sensors used as well as their placement on the body and their associated validation methods based on the application categories. Our investigations show meaningful correlations among the studies within the same application categories. Then, we investigate the data processing architectures of the studies from the hardware point of view, indicating a lack of effort on handling the main processing through on-body units. Finally, we propose combining the discussed applications in a single platform, finding robust ways for artifact cancellation, and planning optimized sensing/processing architectures for them, to be taken more seriously in future research.
Collapse
Affiliation(s)
| | | | - Maarten Weyn
- IDLab-Faculty of Applied Engineering, University of Antwerp-imec, Sint-Pietersvliet 7, 2000 Antwerp, Belgium; (M.H.R.); (R.B.)
| |
Collapse
|
138
|
Despins LA, Guidoboni G, Skubic M, Sala L, Enayati M, Popescu M, Deroche CB. Using Sensor Signals in the Early Detection of Heart Failure: A Case Study. J Gerontol Nurs 2021; 46:41-46. [PMID: 32598000 DOI: 10.3928/00989134-20200605-07] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Early detection of heart failure in older adults will be a significant issue for the foreseeable future. The current article presents a case study to describe how monitoring ballistocardiogram (BCG) waveforms captured non-invasively using sensors placed under a bed mattress can detect early heart failure changes. Heart and respiratory rates obtained from the bed sensor of a female older adult who was hospitalized with acute mixed congestive heart failure, clinic notes, and data from computer simulations reflecting increasing diastolic dysfunction were analyzed. Mean heart and respiratory rate trends obtained from her bed sensor in the prior 2 months did not indicate heart failure. BCG waveforms resulting from the simulations demonstrated changes associated with decreasing cardiac output as diastolic function worsened. Developing new methods for clinically interpreting BCG waveforms presents a significant opportunity for improving early heart failure detection. [Journal of Gerontological Nursing, 46(7), 41-46.].
Collapse
|
139
|
Xia Z, Shandhi MMH, Li Y, Inan OT, Zhang Y. The Delineation of Fiducial Points for Non-Contact Radar Seismocardiogram Signals Without Concurrent ECG. IEEE J Biomed Health Inform 2021; 25:1031-1040. [PMID: 32750965 DOI: 10.1109/jbhi.2020.3009997] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE Non-contact sensing of seismocardiogram (SCG) signals through a microwave Doppler radar is promising for biomedical applications. However, the delineation of fiducial points for radar SCG still relies on concurrent ECG which requires a contact sensor and limits the complete non-contact detection of SCG. METHODS Instead of ECG, a new reference signal, the radar displacement signal of heartbeat (RDH), was derived through the complex Fourier transform and the band pass filtering of the radar signal. The RDH signal was used to locate each cardiac cycle and mask the systolic profile, which was further used to detect an important fiducial point, aortic valve opening (AO). The beat-to-beat interval was estimated from AO-AO interval and compared with the gold standard, ECG R-to-R interval. RESULTS For the 22 subjects in the study, the evaluation of the AOs detected by RDH (AORDH) shows the average detection ratio can reach 90%, indicating a high ratio of the AORDH that are exactly the same as AO detected using the ECG R-wave (AOECG). Additionally, the left ventricular ejection time (LVET) values estimated from the ensemble averaged radar waveform through AORDH segmentation are within 2 ms of those through AOECG segmentation, for all the detected subjects. Further analysis demonstrates that the beat-to-beat intervals calculated from AORDH have an average root-mean-square-deviation (RMSD) of 53.73 ms when compared with ECG R-to-R intervals, and have an average RMSD of 23.47 ms after removing the beats in which AO cannot be identified. CONCLUSIONS Radar signal RDH can be used as a reference signal to delineate fiducial points for non-contact radar SCG signals. SIGNIFICANCE This study can be applied to develop complete non-contact sensing of SCG and monitoring of vital signs, where contact-based SCG is not feasible.
Collapse
|
140
|
Morra S, Pitisci L, Su F, Hossein A, Rabineau J, Racape J, Gorlier D, Herpain A, Migeotte PF, Creteur J, van de Borne P. Quantification of Cardiac Kinetic Energy and Its Changes During Transmural Myocardial Infarction Assessed by Multi-Dimensional Seismocardiography. Front Cardiovasc Med 2021; 8:603319. [PMID: 33763456 PMCID: PMC7982421 DOI: 10.3389/fcvm.2021.603319] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2020] [Accepted: 02/08/2021] [Indexed: 11/24/2022] Open
Abstract
Introduction: Seismocardiography (SCG) records cardiac and blood-induced motions transmitted to the chest surface as vibratory phenomena. Evidences demonstrate that acute myocardial ischemia (AMI) profoundly affects the SCG signals. Multidimensional SCG records cardiac vibrations in linear and rotational dimensions, and scalar parameters of kinetic energy can be computed. We speculate that AMI and revascularization profoundly modify cardiac kinetic energy as recorded by SCG. Methods: Under general anesthesia, 21 swine underwent 90 min of myocardial ischemia induced by percutaneous sub-occlusion of the proximal left anterior descending (LAD) coronary artery and subsequent revascularization. Invasive hemodynamic parameters were continuously recorded. SCG was recorded during baseline, immediately and 80 min after LAD sub-occlusion, and immediately and 60 min after LAD reperfusion. iK was automatically computed for each cardiac cycle (iKCC) in linear (iKLin) and rotational (iKRot) dimensions. iK was calculated as well during systole and diastole (iKSys and iKDia, respectively). Echocardiography was performed at baseline and after revascularization, and the left ventricle ejection fraction (LVEF) along with regional left ventricle (LV) wall abnormalities were evaluated. Results: Upon LAD sub-occlusion, 77% of STEMI and 24% of NSTEMI were observed. Compared to baseline, troponins increased from 13.0 (6.5; 21.3) ng/dl to 170.5 (102.5; 475.0) ng/dl, and LVEF dropped from 65.0 ± 0.0 to 30.6 ± 5.7% at the end of revascularization (both p < 0.0001). Regional LV wall abnormalities were observed as follows: anterior MI, 17.6% (three out of 17); septal MI, 5.8% (one out of 17); antero-septal MI, 47.1% (eight out of 17); and infero-septal MI, 29.4% (five out of 17). In the linear dimension, iKLinCC, iKLinSys, and iKLinDia dropped by 43, 52, and 53%, respectively (p < 0.0001, p < 0.0001, and p = 0.03, respectively) from baseline to the end of reperfusion. In the rotational dimension, iKRotCC and iKRotSys dropped by 30 and 36%, respectively (p = 0.0006 and p < 0.0001, respectively), but iKRotDia did not change (p = 0.41). All the hemodynamic parameters, except the pulmonary artery pulse pressure, were significantly correlated with the parameters of iK, except for the diastolic component. Conclusions: In this very context of experimental AMI with acute LV regional dysfunction and no concomitant AMI-related heart valve disease, linear and rotational iK parameters, in particular, systolic ones, provide reliable information on LV contractile dysfunction and its effects on the downstream circulation. Multidimensional SCG may provide information on the cardiac contractile status expressed in terms of iK during AMI and reperfusion. This automatic system may empower health care providers and patients to remotely monitor cardiovascular status in the near future.
Collapse
Affiliation(s)
- Sofia Morra
- Department of Cardiology, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium
| | - Lorenzo Pitisci
- Department of Cardiology, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium.,Experimental Laboratory of Intensive Care, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium
| | - Fuhong Su
- Experimental Laboratory of Intensive Care, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium
| | - Amin Hossein
- Laboratory of Physic and Physiology (LPHYS), Université Libre de Bruxelles, Brussels, Belgium
| | - Jérémy Rabineau
- Laboratory of Physic and Physiology (LPHYS), Université Libre de Bruxelles, Brussels, Belgium
| | - Judith Racape
- Research Center in Epidemiology, Biostatistics and Clinical Research, School of Public Health, Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Damien Gorlier
- Laboratory of Physic and Physiology (LPHYS), Université Libre de Bruxelles, Brussels, Belgium
| | - Antoine Herpain
- Experimental Laboratory of Intensive Care, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium.,Department of Intensive Care, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium
| | | | - Jacques Creteur
- Department of Intensive Care, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium
| | - Philippe van de Borne
- Department of Cardiology, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium
| |
Collapse
|
141
|
Shandhi MMH, Bartlett WH, Heller JA, Etemadi M, Young A, Plotz T, Inan OT. Estimation of Instantaneous Oxygen Uptake During Exercise and Daily Activities Using a Wearable Cardio-Electromechanical and Environmental Sensor. IEEE J Biomed Health Inform 2021; 25:634-646. [PMID: 32750964 DOI: 10.1109/jbhi.2020.3009903] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
OBJECTIVE To estimate instantaneous oxygen uptake VO2 with a small, low-cost wearable sensor during exercise and daily activities in order to enable monitoring of energy expenditure (EE) in uncontrolled settings. We aim to do so using a combination of seismocardiogram (SCG), electrocardiogram (ECG) and atmospheric pressure (AP) signals obtained from a minimally obtrusive wearable device. METHODS In this study, subjects performed a treadmill protocol in a controlled environment and an outside walking protocol in an uncontrolled environment. During testing, the COSMED K5 metabolic system collected gold standard breath-by-breath (BxB) data and a custom-built wearable patch placed on the mid-sternum collected SCG, ECG and AP signals. We extracted features from these signals to estimate the BxB VO2 data obtained from the COSMED system. RESULTS In estimating instantaneous VO2, we achieved our best results on the treadmill protocol using a combination of SCG (frequency) and AP features (RMSE of 3.68 ± 0.98 ml/kg/min and R2 of 0.77). For the outside protocol, we achieved our best results using a combination of SCG (frequency), ECG and AP features (RMSE of 4.3 ± 1.47 ml/kg/min and R2 of 0.64). In estimating VO2 consumed over one minute intervals during the protocols, our median percentage error was 15.8[Formula: see text] for the treadmill protocol and 20.5[Formula: see text] for the outside protocol. CONCLUSION SCG, ECG and AP signals from a small wearable patch can enable accurate estimation of instantaneous VO2 in both controlled and uncontrolled settings. SCG signals capturing variation in cardio-mechanical processes, AP signals, and state of the art machine learning models contribute significantly to the accurate estimation of instantaneous VO2. SIGNIFICANCE Accurate estimation of VO2 with a low cost, minimally obtrusive wearable patch can enable the monitoring of VO2 and EE in everyday settings and make the many applications of these measurements more accessible to the general public.
Collapse
|
142
|
Ben Nasr MC, Ben Jebara S, Otis S, Abdulrazak B, Mezghani N. A Spectral-Based Approach for BCG Signal Content Classification. SENSORS (BASEL, SWITZERLAND) 2021; 21:1020. [PMID: 33540951 PMCID: PMC7867327 DOI: 10.3390/s21031020] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 01/27/2021] [Accepted: 01/28/2021] [Indexed: 12/04/2022]
Abstract
This paper has two objectives: the first is to generate two binary flags to indicate useful frames permitting the measurement of cardiac and respiratory rates from Ballistocardiogram (BCG) signals-in fact, human body activities during measurements can disturb the BCG signal content, leading to difficulties in vital sign measurement; the second objective is to achieve refined BCG signal segmentation according to these activities. The proposed framework makes use of two approaches: an unsupervised classification based on the Gaussian Mixture Model (GMM) and a supervised classification based on K-Nearest Neighbors (KNN). Both of these approaches consider two spectral features, namely the Spectral Flatness Measure (SFM) and Spectral Centroid (SC), determined during the feature extraction step. Unsupervised classification is used to explore the content of the BCG signals, justifying the existence of different classes and permitting the definition of useful hyper-parameters for effective segmentation. In contrast, the considered supervised classification approach aims to determine if the BCG signal content allows the measurement of the heart rate (HR) and the respiratory rate (RR) or not. Furthermore, two levels of supervised classification are used to classify human-body activities into many realistic classes from the BCG signal (e.g., coughing, holding breath, air expiration, movement, et al.). The first one considers frame-by-frame classification, while the second one, aiming to boost the segmentation performance, transforms the frame-by-frame SFM and SC features into temporal series which track the temporal variation of the measures of the BCG signal. The proposed approach constitutes a novelty in this field and represents a powerful method to segment BCG signals according to human body activities, resulting in an accuracy of 94.6%.
Collapse
Affiliation(s)
- Mohamed Chiheb Ben Nasr
- Higher School of Communication of Tunis, Research Lab. COSIM, Carthage University, Tunis 2088, Tunisia;
| | - Sofia Ben Jebara
- Higher School of Communication of Tunis, Research Lab. COSIM, Carthage University, Tunis 2088, Tunisia;
| | - Samuel Otis
- Laboratoire de Recherche en Imagerie et en Orthopédie, CRCHUM, Montreal, QC H2X 0A9, Canada; (S.O.); (N.M.)
| | - Bessam Abdulrazak
- Department of Computer Science, Sherbrooke University, Sherbrooke, QC J1K 2R1, Canada;
| | - Neila Mezghani
- Laboratoire de Recherche en Imagerie et en Orthopédie, CRCHUM, Montreal, QC H2X 0A9, Canada; (S.O.); (N.M.)
- LICEF Institute, TELUQ University, Montreal, QC H2S 3L4, Canada
| |
Collapse
|
143
|
Beutel F, Van Hoof C, Rottenberg X, Reesink K, Hermeling E. Pulse Arrival Time Segmentation Into Cardiac and Vascular Intervals - Implications for Pulse Wave Velocity and Blood Pressure Estimation. IEEE Trans Biomed Eng 2021; 68:2810-2820. [PMID: 33513094 DOI: 10.1109/tbme.2021.3055154] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE This study demonstrates a novel method for pulse arrival time (PAT) segmentation into cardiac isovolumic contraction (IVC) and vascular pulse transit time to approximate central pulse wave velocity (PWV). METHODS 10 subjects (38 ± 10 years, 121 ± 12 mmHg SBP) ranging from normotension to hypertension were repeatedly measured at rest and with induced changes in blood pressure (BP), and thus PWV. ECG was recorded simultaneously with ultrasound-based carotid distension waveforms, a photoplethysmography-based peripheral waveform, noninvasive continuous and intermittent cuff BP. Central PAT was segmented into cardiac and vascular time intervals using a fiducial point in the carotid distension waveform that reflects the IVC onset. Central and peripheral PWVs were computed from (segmented) intervals and estimated arterial path lengths. Correlations with Bramwell-Hill PWV, systolic and diastolic BP (SBP/DBP) were analyzed by linear regression. RESULTS Central PWV explained more than twice the variability (R2) in Bramwell-Hill PWV compared to peripheral PWV (0.56 vs. 0.27). SBP estimated from central PWV undercuts the IEEE mean absolute deviation threshold of 5 mmHg, significantly lower than peripheral PWV or PAT (4.2 vs. 7.1 vs. 10.1 mmHg). CONCLUSION Cardiac IVC onset signaled in carotid distension waveforms enables PAT segmentation to obtain unbiased vascular pulse transit time. Corresponding PWV estimates provide the basis for single-site assessment of central arterial stiffness, confirmed by significant correlations with Bramwell-Hill PWV and SBP. SIGNIFICANCE In a small-scale cohort, we present proof-of-concept for a novel method to estimate central PWV and BP, bearing potential to improve the practicality of cardiovascular risk assessment in clinical routines.
Collapse
|
144
|
Ladrova M, Martinek R, Nedoma J, Hanzlikova P, Nelson MD, Kahankova R, Brablik J, Kolarik J. Monitoring and Synchronization of Cardiac and Respiratory Traces in Magnetic Resonance Imaging: A Review. IEEE Rev Biomed Eng 2021; 15:200-221. [PMID: 33513108 DOI: 10.1109/rbme.2021.3055550] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Synchronization of human vital signs, namely the cardiac cycle and respiratory excursions, is necessary during magnetic resonance imaging of the cardiovascular system and the abdominal cavity to achieve optimal image quality with minimized artifacts. This review summarizes techniques currently available in clinical practice, as well as methods under development, outlines the benefits and disadvantages of each approach, and offers some unique solutions for consideration.
Collapse
|
145
|
Hossein A, Rabineau J, Gorlier D, Del Rio JIJ, van de Borne P, Migeotte PF, Nonclercq A. Kinocardiography Derived from Ballistocardiography and Seismocardiography Shows High Repeatability in Healthy Subjects. SENSORS (BASEL, SWITZERLAND) 2021; 21:815. [PMID: 33530417 PMCID: PMC7865512 DOI: 10.3390/s21030815] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Revised: 01/20/2021] [Accepted: 01/21/2021] [Indexed: 01/14/2023]
Abstract
Recent years have witnessed an upsurge in the usage of ballistocardiography (BCG) and seismocardiography (SCG) to record myocardial function both in normal and pathological populations. Kinocardiography (KCG) combines these techniques by measuring 12 degrees-of-freedom of body motion produced by myocardial contraction and blood flow through the cardiac chambers and major vessels. The integral of kinetic energy (iK) obtained from the linear and rotational SCG/BCG signals, and automatically computed over the cardiac cycle, is used as a marker of cardiac mechanical function. The present work systematically evaluated the test-retest (TRT) reliability of KCG iK derived from BCG/SCG signals in the short term (<15 min) and long term (3-6 h) on 60 healthy volunteers. Additionally, we investigated the difference of repeatability with different body positions. First, we found high short-term TRT reliability for KCG metrics derived from SCG and BCG recordings. Exceptions to this finding were limited to metrics computed in left lateral decubitus position where the TRT reliability was moderate-to-high. Second, we found low-to-moderate long-term TRT reliability for KCG metrics as expected and confirmed by blood pressure measurements. In summary, KCG parameters derived from BCG/SCG signals show high repeatability and should be further investigated to confirm their use for cardiac condition longitudinal monitoring.
Collapse
Affiliation(s)
- Amin Hossein
- LPHYS, Université Libre de Bruxelles, 1050 Bruxelles, Belgium; (J.R.); (D.G.); (P.-F.M.)
- BEAMS, Université Libre de Bruxelles, 1050 Bruxelles, Belgium;
| | - Jérémy Rabineau
- LPHYS, Université Libre de Bruxelles, 1050 Bruxelles, Belgium; (J.R.); (D.G.); (P.-F.M.)
| | - Damien Gorlier
- LPHYS, Université Libre de Bruxelles, 1050 Bruxelles, Belgium; (J.R.); (D.G.); (P.-F.M.)
| | - Jose Ignacio Juarez Del Rio
- Department of Cardiology, Erasme Hospital, Université Libre de Bruxelles, 1050 Bruxelles, Belgium; (J.I.J.D.R.); (P.v.d.B.)
| | - Philippe van de Borne
- Department of Cardiology, Erasme Hospital, Université Libre de Bruxelles, 1050 Bruxelles, Belgium; (J.I.J.D.R.); (P.v.d.B.)
| | | | | |
Collapse
|
146
|
Morra S, Hossein A, Rabineau J, Gorlier D, Racape J, Migeotte PF, van de Borne P. Assessment of left ventricular twist by 3D ballistocardiography and seismocardiography compared with 2D STI echocardiography in a context of enhanced inotropism in healthy subjects. Sci Rep 2021; 11:683. [PMID: 33436841 PMCID: PMC7804966 DOI: 10.1038/s41598-020-79933-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Accepted: 12/14/2020] [Indexed: 12/17/2022] Open
Abstract
Ballistocardiography (BCG) and Seismocardiography (SCG) assess the vibrations produced by cardiac contraction and blood flow, respectively, by means of micro-accelerometers and micro-gyroscopes. From the BCG and SCG signals, maximal velocities (VMax), integral of kinetic energy (iK), and maximal power (PMax) can be computed as scalar parameters, both in linear and rotational dimensions. Standard echocardiography and 2-dimensional speckle tracking imaging echocardiography were performed on 34 healthy volunteers who were infused with increasing doses of dobutamine (5-10-20 μg/kg/min). Linear VMax of BCG predicts the rates of left ventricular (LV) twisting and untwisting (both p < 0.0001). The linear PMax of both SCG and BCG and the linear iK of BCG are the best predictors of the LV ejection fraction (LVEF) (p < 0.0001). This result is further confirmed by mathematical models combining the metrics from SCG and BCG signals with heart rate, in which both linear PMax and iK strongly correlate with LVEF (R = 0.7, p < 0.0001). In this setting of enhanced inotropism, the linear VMax of BCG, rather than the VMax of SCG, is the metric which best explains the LV twist mechanics, in particular the rates of twisting and untwisting. PMax and iK metrics are strongly associated with the LVEF and account for 50% of the variance of the LVEF.
Collapse
Affiliation(s)
- Sofia Morra
- Department of Cardiovascular Diseases, Erasme Hospital, Université Libre de Bruxelles (ULB), Brussels, Belgium.
| | - Amin Hossein
- Laboratory of Physic and Physiology (LPHYS), Université Libre de Bruxelles (ULB), Brussels, Belgium.
| | - Jérémy Rabineau
- Laboratory of Physic and Physiology (LPHYS), Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Damien Gorlier
- Laboratory of Physic and Physiology (LPHYS), Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Judith Racape
- Research Centre in Epidemiology, Biostatistics and Clinical Research, School of Public Health, Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Pierre-François Migeotte
- Laboratory of Physic and Physiology (LPHYS), Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Philippe van de Borne
- Department of Cardiovascular Diseases, Erasme Hospital, Université Libre de Bruxelles (ULB), Brussels, Belgium
| |
Collapse
|
147
|
Hossein A, Rabineau J, Gorlier D, Pinki F, van de Borne P, Nonclercq A, Migeotte PF. Effects of acquisition device, sampling rate, and record length on kinocardiography during position-induced haemodynamic changes. Biomed Eng Online 2021; 20:3. [PMID: 33407507 PMCID: PMC7788803 DOI: 10.1186/s12938-020-00837-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Accepted: 12/10/2020] [Indexed: 12/02/2022] Open
Abstract
BACKGROUND Kinocardiography (KCG) is a promising new technique used to monitor cardiac mechanical function remotely. KCG is based on ballistocardiography (BCG) and seismocardiography (SCG), and measures 12 degrees-of-freedom (DOF) of body motion produced by myocardial contraction and blood flow through the cardiac chambers and major vessels. RESULTS The integral of kinetic energy ([Formula: see text]) obtained from the linear and rotational SCG/BCG signals was computed over each dimension over the cardiac cycle, and used as a marker of cardiac mechanical function. We tested the hypotheses that KCG metrics can be acquired using different sensors, and at 50 Hz. We also tested the effect of record length on the ensemble average on which the metrics were computed. Twelve healthy males were tested in the supine, head-down tilt, and head-up tilt positions to expand the haemodynamic states on which the validation was performed. CONCLUSIONS KCG metrics computed on 50 Hz and 1 kHz SCG/BCG signals were very similar. Most of the metrics were highly similar when computed on different sensors, and with less than 5% of error when computed on record length longer than 60 s. These results suggest that KCG may be a robust and non-invasive method to monitor cardiac inotropic activity. Trial registration Clinicaltrials.gov, NCT03107351. Registered 11 April 2017, https://clinicaltrials.gov/ct2/show/NCT03107351?term=NCT03107351&draw=2&rank=1 .
Collapse
Affiliation(s)
- Amin Hossein
- LPHYS, Université Libre de Bruxelles, Brussels, Belgium.
- BEAMS, Université Libre de Bruxelles, Brussels, Belgium.
| | | | | | - Farhana Pinki
- LPHYS, Université Libre de Bruxelles, Brussels, Belgium
| | - Philippe van de Borne
- Department of Cardiology, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium
| | | | | |
Collapse
|
148
|
Wu H, Yang G, Zhu K, Liu S, Guo W, Jiang Z, Li Z. Materials, Devices, and Systems of On-Skin Electrodes for Electrophysiological Monitoring and Human-Machine Interfaces. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2021; 8:2001938. [PMID: 33511003 PMCID: PMC7816724 DOI: 10.1002/advs.202001938] [Citation(s) in RCA: 142] [Impact Index Per Article: 35.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Revised: 09/19/2020] [Indexed: 05/05/2023]
Abstract
On-skin electrodes function as an ideal platform for collecting high-quality electrophysiological (EP) signals due to their unique characteristics, such as stretchability, conformal interfaces with skin, biocompatibility, and wearable comfort. The past decade has witnessed great advancements in performance optimization and function extension of on-skin electrodes. With continuous development and great promise for practical applications, on-skin electrodes are playing an increasingly important role in EP monitoring and human-machine interfaces (HMI). In this review, the latest progress in the development of on-skin electrodes and their integrated system is summarized. Desirable features of on-skin electrodes are briefly discussed from the perspective of performances. Then, recent advances in the development of electrode materials, followed by the analysis of strategies and methods to enhance adhesion and breathability of on-skin electrodes are examined. In addition, representative integrated electrode systems and practical applications of on-skin electrodes in healthcare monitoring and HMI are introduced in detail. It is concluded with the discussion of key challenges and opportunities for on-skin electrodes and their integrated systems.
Collapse
Affiliation(s)
- Hao Wu
- Flexible Electronics Research CenterState Key Laboratory of Digital Manufacturing Equipment and TechnologySchool of Mechanical Science and EngineeringHuazhong University of Science and TechnologyWuhanHubei430074China
| | - Ganguang Yang
- Flexible Electronics Research CenterState Key Laboratory of Digital Manufacturing Equipment and TechnologySchool of Mechanical Science and EngineeringHuazhong University of Science and TechnologyWuhanHubei430074China
| | - Kanhao Zhu
- Flexible Electronics Research CenterState Key Laboratory of Digital Manufacturing Equipment and TechnologySchool of Mechanical Science and EngineeringHuazhong University of Science and TechnologyWuhanHubei430074China
| | - Shaoyu Liu
- Flexible Electronics Research CenterState Key Laboratory of Digital Manufacturing Equipment and TechnologySchool of Mechanical Science and EngineeringHuazhong University of Science and TechnologyWuhanHubei430074China
| | - Wei Guo
- Flexible Electronics Research CenterState Key Laboratory of Digital Manufacturing Equipment and TechnologySchool of Mechanical Science and EngineeringHuazhong University of Science and TechnologyWuhanHubei430074China
| | - Zhuo Jiang
- Department of Materials ScienceFudan UniversityShanghai200433China
| | - Zhuo Li
- Department of Materials ScienceFudan UniversityShanghai200433China
| |
Collapse
|
149
|
Rajput JS, Sharma M, Kumbhani D, Acharya UR. Automated detection of hypertension using wavelet transform and nonlinear techniques with ballistocardiogram signals. INFORMATICS IN MEDICINE UNLOCKED 2021. [DOI: 10.1016/j.imu.2021.100736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
150
|
Carlson C, Turpin VR, Suliman A, Ade C, Warren S, Thompson DE. Bed-Based Ballistocardiography: Dataset and Ability to Track Cardiovascular Parameters. SENSORS (BASEL, SWITZERLAND) 2020; 21:E156. [PMID: 33383739 PMCID: PMC7795624 DOI: 10.3390/s21010156] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 12/19/2020] [Accepted: 12/22/2020] [Indexed: 12/13/2022]
Abstract
BACKGROUND The goal of this work was to create a sharable dataset of heart-driven signals, including ballistocardiograms (BCGs) and time-aligned electrocardiograms (ECGs), photoplethysmograms (PPGs), and blood pressure waveforms. METHODS A custom, bed-based ballistocardiographic system is described in detail. Affiliated cardiopulmonary signals are acquired using a GE Datex CardioCap 5 patient monitor (which collects ECG and PPG data) and a Finapres Medical Systems Finometer PRO (which provides continuous reconstructed brachial artery pressure waveforms and derived cardiovascular parameters). RESULTS Data were collected from 40 participants, 4 of whom had been or were currently diagnosed with a heart condition at the time they enrolled in the study. An investigation revealed that features extracted from a BCG could be used to track changes in systolic blood pressure (Pearson correlation coefficient of 0.54 +/- 0.15), dP/dtmax (Pearson correlation coefficient of 0.51 +/- 0.18), and stroke volume (Pearson correlation coefficient of 0.54 +/- 0.17). CONCLUSION A collection of synchronized, heart-driven signals, including BCGs, ECGs, PPGs, and blood pressure waveforms, was acquired and made publicly available. An initial study indicated that bed-based ballistocardiography can be used to track beat-to-beat changes in systolic blood pressure and stroke volume. SIGNIFICANCE To the best of the authors' knowledge, no other database that includes time-aligned ECG, PPG, BCG, and continuous blood pressure data is available to the public. This dataset could be used by other researchers for algorithm testing and development in this fast-growing field of health assessment, without requiring these individuals to invest considerable time and resources into hardware development and data collection.
Collapse
Affiliation(s)
- Charles Carlson
- Mike Wiegers Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506, USA; (A.S.); (S.W.); (D.E.T.)
| | - Vanessa-Rose Turpin
- Department of Kinesiology, Kansas State University, Manhattan, KS 66506, USA; (V.-R.T.); (C.A.)
| | - Ahmad Suliman
- Mike Wiegers Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506, USA; (A.S.); (S.W.); (D.E.T.)
| | - Carl Ade
- Department of Kinesiology, Kansas State University, Manhattan, KS 66506, USA; (V.-R.T.); (C.A.)
| | - Steve Warren
- Mike Wiegers Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506, USA; (A.S.); (S.W.); (D.E.T.)
| | - David E. Thompson
- Mike Wiegers Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506, USA; (A.S.); (S.W.); (D.E.T.)
| |
Collapse
|