101
|
Kanazirski N, Vladova D, Neychev D, Raycheva R, Kanazirska P. Effect of Er:YAG Laser Exposure on the Amorphous Smear Layer in the Marginal Zone of the Osteotomy Site for Placement of Dental Screw Implants: A Histomorphological Study. J Funct Biomater 2023; 14:376. [PMID: 37504871 PMCID: PMC10381257 DOI: 10.3390/jfb14070376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 07/12/2023] [Accepted: 07/13/2023] [Indexed: 07/29/2023] Open
Abstract
The placement of dental screw implants typically involves the use of rotary techniques and drills to create a bone bed. This study explores the potential benefits of combining this method with an Er:YAG laser. Split osteotomies were performed on 10 jaws of euthanized domestic pigs (Sus scrofa domestica), with 12 mandibular implant osteotomies in each jaw, divided into 4 groups. In order to make a comprehensive assessment of the effect of Er:YAG lasers, histomorphological techniques were used to measure the reduction in amorphous layer thickness after Er:YAG laser treatment, both with and without the placement of dental screw implants from different manufacturers. Following bone decalcification and staining, the thickness of the amorphous layer was measured in four groups: Group A-osteotomy performed without Er:YAG laser treatment-had amorphous layer thicknesses ranging from 21.813 to 222.13 µm; Group B-osteotomy performed with Er:YAG laser treatment-had amorphous layer thicknesses ranging from 6.08 to 64.64 µm; Group C-an implant placed in the bone without laser treatment-had amorphous layer thicknesses of 5.90 to 54.52 µm; and Group D-an implant placed after bone treatment with Er:YAG laser-had amorphous layer thicknesses of 1.29 to 7.98 µm. The examination and photomicrodocumentation was performed using a LEICA DM1000 LED microscope (Germany) and LAS V 4.8 software (Leica Application Suite V4, Leica Microsystems, Germany). When comparing group A to group B and group C to D, statistically significant differences were indicated (p-value = 0.000, p < 0.05). The study demonstrates the synergistic effects and the possibility of integrating lasers into the conventional implantation protocol. By applying our own method of biomodification, the smear layer formed during rotary osteotomy can be reduced using Er:YAG lasers. This reduction leads to a narrower peri-implant space and improved bone-to-implant contact, facilitating accelerated osseointegration.
Collapse
Affiliation(s)
- Nikolay Kanazirski
- Department of Oral Surgery, Faculty of Dental Medicine, Medical University-Plovdiv, 4000 Plovdiv, Bulgaria
| | - Diyana Vladova
- Department of Veterinary Anatomy, Histology and Embryology, Faculty of Veterinary Medicine, Trakia University, 6000 Stara Zagora, Bulgaria
| | - Deyan Neychev
- Department of Oral Surgery, Faculty of Dental Medicine, Medical University-Plovdiv, 4000 Plovdiv, Bulgaria
| | - Ralitsa Raycheva
- Department of Social Medicine and Public Health, Faculty of Public Health, Medical University-Plovdiv, 4000 Plovdiv, Bulgaria
| | - Petya Kanazirska
- Department of Imaging Diagnostics, Dental Allergology and Physiotherapy, Faculty of Dental Medicine, Medical University-Plovdiv, 4000 Plovdiv, Bulgaria
| |
Collapse
|
102
|
Al Deeb M, Aldosari AA, Anil S. Osseointegration of Tantalum Trabecular Metal in Titanium Dental Implants: Histological and Micro-CT Study. J Funct Biomater 2023; 14:355. [PMID: 37504850 PMCID: PMC10382015 DOI: 10.3390/jfb14070355] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2023] [Revised: 06/26/2023] [Accepted: 07/02/2023] [Indexed: 07/29/2023] Open
Abstract
This study aimed to investigate the impact of the Tantalum Trabecular Metal dental implant design on implant stability and the process of osseointegration following its placement in the rabbit femoral condyle. The subjects for the experiment consisted of 10 New Zealand white rabbits. Twenty implants, comprising 10 Trabecular Metal (TM) and 10 Traditional Screw Vent (TSV) implants, were placed into the femoral condyles of these rabbits. The implant type was alternated based on a random sequence. Following a healing period of 8 weeks, the implants were retrieved for further analysis using micro-computed tomography (micro-CT), histological studies, and histomorphometry evaluations. The Bone-to-Implant Contact (BIC) ratio and the Bone Volume (BV) percentage in the region of interest were subsequently assessed. The BIC and BV values between TM and TSV implants were compared using the Student t-test. The TM implants exhibited significantly greater BIC and BV scores. In particular, the BIC percentage was recorded as 57.9 ± 6.5 for the TM implants, as opposed to 47.6 ± 8 for the TSV implants. Correspondingly, the BV percentage was 57 ± 7.3 for the TM implants and 46.4 ± 7.4 for the TSV implants. The bone volume percentage measured using micro-CT evaluation was 89.1 ± 8.7 for the TM implants and 79.1 ± 8.6 for the TSV implants. Given the observed results, it is plausible to suggest that the bone growth surrounding the tantalum mesh could have improved the integration of the bone and facilitated its ingrowth into the TM implant.
Collapse
Affiliation(s)
- Modhi Al Deeb
- Department of Prosthetic Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia
| | - Abdullah AlFarraj Aldosari
- Department of Prosthetic Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia
| | - Sukumaran Anil
- Department of Dentistry, Oral Health Institute, Hamad Medical Corporation, Doha P.O. Box 3050, Qatar
| |
Collapse
|
103
|
Haokip N, Tewary S, Sanyal P, Kamnoor S. To determine the effect of plasma nitriding treatment 56 on screw loosening and surface topography of different 78 implant-abutment screw systems with and without thermocycling: An in vitro study. J Indian Prosthodont Soc 2023; 23:285-293. [PMID: 37929368 PMCID: PMC10467315 DOI: 10.4103/jips.jips_147_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 06/27/2023] [Accepted: 06/28/2023] [Indexed: 11/07/2023] Open
Abstract
Aim The aim of this study was to evaluate and compare the effect of plasma nitride-treated abutment screws of two different implant systems on screw loosening and surface topography with and without thermocycling. Settings and Design This was an in-vitro experimental study. Materials and Methods Fifty-two abutment screws (Group A: 26 Genesis and Group B: 26 Bredent) underwent plasma nitride treatment and were subdivided into two groups, one without thermocycling and one with thermocycling. Dynamic load was applied and detorque values were evaluated for determining the screw loosening using "independent t-test" with the help of IBM SPSS Statistics 20 and scanning electron microscopy was done to check for surface topography. Statistical Analysis Used Inter- and intragroup comparisons were done using independent t-test (SPSS: Statistical Package for the Social Sciences software version 20). Results Plasma nitriding treatment genesis implant system abutment screw showed more screw loosening (P < 0.05) and surface roughness as compared to bredent with and without thermocycling. Conclusion From the present study, it was shown that plasma nitride-treated abutment screws decreased the occurrence of screw loosening favoring the bredent implant-abutment system more than the genesis implant-abutment system.
Collapse
Affiliation(s)
- Nengpichong Haokip
- Department of Prosthodontics and Crown and Bridge, School of Dental Sciences, Krishna Vishwa Vidyapeeth Deemed to be University, Karad, Maharashtra, India
| | - Shivsagar Tewary
- Department of Prosthodontics and Crown and Bridge, School of Dental Sciences, Krishna Vishwa Vidyapeeth Deemed to be University, Karad, Maharashtra, India
| | - Pronob Sanyal
- Department of Prosthodontics and Crown and Bridge, School of Dental Sciences, Krishna Vishwa Vidyapeeth Deemed to be University, Karad, Maharashtra, India
| | - Shubha Kamnoor
- Department of Prosthodontics and Crown and Bridge, School of Dental Sciences, Krishna Vishwa Vidyapeeth Deemed to be University, Karad, Maharashtra, India
| |
Collapse
|
104
|
Conforte JJ, Sousa CA, da Silva ACR, Ribeiro AV, Duque C, Assunção WG. Effect of Enterococcus faecalis Biofilm on Corrosion Kinetics in Titanium Grade 4 Alloys with Different Surface Treatments. MATERIALS (BASEL, SWITZERLAND) 2023; 16:4532. [PMID: 37444846 DOI: 10.3390/ma16134532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 06/09/2023] [Accepted: 06/20/2023] [Indexed: 07/15/2023]
Abstract
E. faecalis has been associated with bacteremia, sepsis, and bacterial endocarditis and peri-implantitis. This microorganism can remain in the alveolus even after extraction of the root remnant. This study aimed to evaluate the corrosion on different surfaces of commercially pure titanium (Ti) grade 4 (Ticp-G4) as a function of the bacterial biofilm effect of Enterococcus faecalis. A total of 57 discs were randomly divided according to their surface finish (n = 19). For microbiological analysis (n = 9), the discs were placed in 12-well plates containing E. faecalis culture and incubated at 37 °C for 7 days. The results show that for the intergroup analysis, considering the "electrolyte" factor, there was a difference between the groups. There was greater biofilm formation for the D.A.Zir group, with greater electrochemical exchange for Biofilm, and the presence of biofilm favored greater electrochemical exchange with the medium.
Collapse
Affiliation(s)
- Jadison Junio Conforte
- Department of Dental Materials and Prosthodontic, Araçatuba School of Dentistry, São Paulo State University (UNESP), Sao Paulo 16015-050, Brazil
| | - Cecília Alves Sousa
- Department of Dental Materials and Prosthodontic, Araçatuba School of Dentistry, São Paulo State University (UNESP), Sao Paulo 16015-050, Brazil
| | - Ana Claudia Rodrigues da Silva
- Department of Preventive and Restorative Dentistry, Araçatuba School of Dentistry, São Paulo State University (UNESP), Sao Paulo 16015-050, Brazil
| | | | - Cristiane Duque
- Department of Preventive and Restorative Dentistry, Araçatuba School of Dentistry, São Paulo State University (UNESP), Sao Paulo 16015-050, Brazil
| | - Wirley Gonçalves Assunção
- Department of Dental Materials and Prosthodontic, Araçatuba School of Dentistry, São Paulo State University (UNESP), Sao Paulo 16015-050, Brazil
| |
Collapse
|
105
|
Wu N, Gao H, Wang X, Pei X. Surface Modification of Titanium Implants by Metal Ions and Nanoparticles for Biomedical Application. ACS Biomater Sci Eng 2023; 9:2970-2990. [PMID: 37184344 DOI: 10.1021/acsbiomaterials.2c00722] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Implant surface modification can improve osseointegration and reduce peri-implant inflammation. Implant surfaces are modified with metals because of their excellent mechanical properties and significant functions. Metal surface modification is divided into metal ions and nanoparticle surface modification. These two methods function by adding a finishing metal to the surface of the implant, and both play a role in promoting osteogenic, angiogenic, and antibacterial properties. Based on this, the nanostructural surface changes confer stronger antibacterial and cellular affinity to the implant surface. The current paper reviews the forms, mechanisms, and applications of nanoparticles and metal ion modifications to provide a foundation for the surface modification of implants.
Collapse
Affiliation(s)
- Nan Wu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| | - Hongyu Gao
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| | - Xu Wang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| | - Xibo Pei
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| |
Collapse
|
106
|
Ashkani O, Tavighi MR, Karamimoghadam M, Moradi M, Bodaghi M, Rezayat M. Influence of Aluminum and Copper on Mechanical Properties of Biocompatible Ti-Mo Alloys: A Simulation-Based Investigation. MICROMACHINES 2023; 14:mi14051081. [PMID: 37241705 DOI: 10.3390/mi14051081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 05/16/2023] [Accepted: 05/18/2023] [Indexed: 05/28/2023]
Abstract
The use of titanium and titanium-based alloys in the human body due to their resistance to corrosion, implant ology and dentistry has led to significant progress in promoting new technologies. Regarding their excellent mechanical, physical and biological performance, new titanium alloys with non-toxic elements and long-term performance in the human body are described today. The main compositions of Ti-based alloys and properties comparable to existing classical alloys (C.P. TI, Ti-6Al-4V, Co-Cr-Mo, etc.) are used for medical applications. The addition of non-toxic elements such as Mo, Cu, Si, Zr and Mn also provides benefits, such as reducing the modulus of elasticity, increasing corrosion resistance and improving biocompatibility. In the present study, when choosing Ti-9Mo alloy, aluminum and copper (Cu) elements were added to it. These two alloys were chosen because one element is considered a favorable element for the body (copper) and the other element is harmful to the body (aluminum). By adding the copper alloy element to the Ti-9Mo alloy, the elastic modulus decreases to a minimum value of 97 GPa, and the aluminum alloy element increases the elastic modulus up to 118 GPa. Due to their similar properties, Ti-Mo-Cu alloys are found to be a good optional alloy to use.
Collapse
Affiliation(s)
- Omid Ashkani
- Department of Materials Science and Engineering, Faculty of Engineering, Islamic Azad University, Science and Research Branch, Tehran 1477893855, Iran
| | - Mohammad Reza Tavighi
- Department of Materials Science and Engineering, Faculty of Engineering, Islamic Azad University, Karaj 3149968111, Iran
| | - Mojtaba Karamimoghadam
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Mahmoud Moradi
- Faculty of Arts, Science and Technology, University of Northampton, Northampton NN1 5PH, UK
| | - Mahdi Bodaghi
- Department of Engineering, School of Science and Technology, Nottingham Trent University, Nottingham NG11 8NS, UK
| | - Mohammad Rezayat
- Center for Structural Integrity, Micromechanics, and Reliability of Materials (CIEFMA)-Department of Materials Science and Engineering, Universitat Politècnica de Catalunya-BarcelonaTECH, 08019 Barcelona, Spain
| |
Collapse
|
107
|
Vyas R, Khurana S, Khurana D, Singer SR, Creanga AG. Cone Beam Computed Tomography (CBCT) Evaluation of Alveolar Bone Thickness and Root Angulation in Anterior Maxilla for Planning Immediate Implant Placement. Cureus 2023; 15:e37875. [PMID: 37213997 PMCID: PMC10199654 DOI: 10.7759/cureus.37875] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/20/2023] [Indexed: 05/23/2023] Open
Abstract
OBJECTIVE This retrospective study aimed to measure the labial, palatal, mesial, and distal bone thickness around maxillary central and lateral incisors and canines and height from crest to apex, using cone beam computed tomography (CBCT) images and compare the results based on gender. The second objective of the study was to measure root angulation on CBCT images and its relation with the labial cortical thicknesses. Material and Methods: After the Institutional Review Board (IRB) approval, a total of 140 CBCT volumes were included in this study according to the set criteria. On each scan, right-side maxillary central, lateral incisors, and canine were selected for the measurements. All the measurements were done at three levels at the alveolar crest (L1), mid-root (L2), and apical region (L3) for each tooth. Results: The Student's t-test was performed to compare the result of buccal, palatal, mesial, and distal bone thickness, angulation, and height of all subjects. Buccal alveolar bone thickness was minimum at the mid-root region, and the palatal bone thickness was minimum at the crestal region. The mesial bone thickness was minimum at the mid-root level, and distal bone thickness was minimum at the crest level. The available bone height was maximum at the lateral incisor and equal for the central incisor and canine. The canine was the most angulated tooth. CONCLUSION Cone beam computed tomography is a reliable imaging modality to evaluate pre-surgical immediate implant sites and measure alveolar bone thickness. The canine was the most angulated tooth with more buccal alveolar bone thickness.
Collapse
Affiliation(s)
- Rutvi Vyas
- Oral and Maxillofacial Radiology, University of Florida Health, Gainesville, USA
| | - Sonam Khurana
- Oral Pathology, Radiology, and Medicine, New York University (NYU) College of Dentistry, New York, USA
| | - Dhruv Khurana
- Addiction Psychiatry, University of California Los Angeles David Geffen School of Medicine, Los Angeles, USA
| | - Steven Rrrrr Singer
- Diagnsotic Sciences, Rutgers, Newark, USA
- Diagnostic Sciences, Rutgers School of Dental Medicine, Newark, USA
| | - Adriana G Creanga
- Oral and Maxillofacial Radiology, Rutgers School of Dental Medicine, Newark, USA
| |
Collapse
|
108
|
Jafarpour Mahalleh A, Mesgarzadeh AH, Jarolmasjed S, Soltani Somee A, Khordadmehr M, Rezaei Y, Maleki Dizaj S, Shahi S. Extracorporeal Shock Wave Therapy as a Helpful Method for Rapid Osseointegration of Dental Implants: Animal Study. Biomimetics (Basel) 2023; 8:biomimetics8020137. [PMID: 37092389 PMCID: PMC10123648 DOI: 10.3390/biomimetics8020137] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Revised: 03/19/2023] [Accepted: 03/25/2023] [Indexed: 03/30/2023] Open
Abstract
The aim of this study was to assess the multi-phasic use of extracorporeal shock wave therapy (ESWT) as an adjuvant treatment to accelerate the osseointegration of titanium dental implants. Initially, twelve titanium mini-screws were inserted in femur bones of six New Zealand rabbits in three groups; the one-time treated group, the three-time treated group, and the control group (without ESWT). Then, 1800 focused shockwaves with an energy flux density of 0.3 mJ/mm2 in every phase were used. Fourteen days after the last phase of ESWT, the animals were sacrificed to assess the osseointegration of screws via micro-computed tomography scan (micro-CT scan), biomechanical pull-out test, and histopathological analysis. Pull-out and histopathology analysis showed that the ESWT significantly increased bone regeneration and osseointegration around the implants compared to the control group (p < 0.05). Moreover, the pull-out test confirmed that the three-time treated screws needed more force to pull the bone out compared to the other two groups (p < 0.05). The mean bone volume fraction between the control group, the one-time treated group, and the three-time treatment group were not statistically significant (p > 0.05) according to the micro-CT scan results. Based on our results, ESWT can be suggested as a non-invasive and cost-effective adjuvant for osseointegration of dental implants. However, more in vivo studies and clinical trials are needed for validation of this finding.
Collapse
|
109
|
Efficacy of Hyaluronic Acid in Relieving Post-implantation Pain: A Split-Mouth Randomized Controlled Trial. Cureus 2023; 15:e36575. [PMID: 36968680 PMCID: PMC10035270 DOI: 10.7759/cureus.36575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/23/2023] [Indexed: 03/25/2023] Open
Abstract
Background Many patients suffer from some degree of pain following the surgical procedures of dental implantation. The fear of pain may be one reason for postponing such prosthodontic treatments. Many procedures have been suggested to control post-implantation pain. This trial evaluated the effectiveness of using hyaluronic acid (HA) during dental implantation on patients’ perceived pain during the postsurgical soft-tissue healing period. Methodology A split-mouth randomized controlled trial (RCT) was conducted. The trial sample consisted of 22 dental implants in 11 patients (five males and six females). Patients were selected from those attending the Department of Oral Medicine at the Faculty of Dentistry, University of Damascus between February 2021 and May 2022. The implants were performed in similar bone quality and density for each patient as the implants were inserted in the same jaw on both sides to ensure the same physiological conditions. The study sample was divided into two groups. The first group (the experimental group) consisted of 11 implants in which the implant site was drilled, following which HA was placed inside the implant site and on the surrounding bone before the flap was returned and sutured. The second group (the control group) comprised 11 implants following the conventional procedure without applying any material to the implant socket. The main outcome measure was pain perception which was assessed using the visual analog scale (VAS). Patients were asked to record their perceived pain on the first, third, and tenth days. Two-sample t-tests were used to detect significant differences. Results There were statistically significant differences in the mean pain intensity between the experimental and control groups on the first, third, and tenth days (p < 0.05). The mean values of perceived pain in the control group were 5.68, 1.72, and 0.56 on the first, third, and tenth days, respectively. In comparison, the mean values of perceived pain in the experimental group were 4.52, 1.14, and 0.18 on the first, third, and tenth days, respectively. The maximum perceived pain in the control group was 7.5 on the first day following implantation, whereas the maximum value recorded in the experimental group was 6.5. At the third assessment time (i.e., 10 days following the surgical intervention), the mean values were in the very mild category of pain intensity. Conclusions This study showed that applying HA in the implant cavity and on the surrounding bone effectively reduced pain after dental implant surgery in comparison with the control group. Patients had lower mean pain scores at one, three, and ten days following surgery compared to the conventional method. HA is suggested to be an adjunctive method to control postsurgical pain after dental implantation.
Collapse
|
110
|
Areid N, Riivari S, Abushahba F, Shahramian K, Närhi T. Influence of Surface Characteristics of TiO 2 Coatings on the Response of Gingival Cells: A Systematic Review of In Vitro Studies. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2533. [PMID: 36984413 PMCID: PMC10056999 DOI: 10.3390/ma16062533] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 03/16/2023] [Accepted: 03/20/2023] [Indexed: 06/18/2023]
Abstract
The soft tissue-implant interface requires the formation of epithelium and connective tissue seal to hinder microbial infiltration and prevent epithelial down growth. Nanoporous titanium dioxide (TiO2) surface coatings have shown good potential for promoting soft tissue attachment to implant surfaces. However, the impact of their surface properties on the biological response of gingival cells needs further investigation. This systematic review aimed to investigate the cellular behavior of gingival cells on TiO2-implant abutment coatings based on in vitro studies. The review was performed to answer the question: "How does the surface characteristic of TiO2 coatings influence the gingival cell response in in vitro studies?". A search in MEDLINE/PubMed and the web of science databases from 1990 to 2022 was performed using keywords. A quality assessment of the studies selected was performed using the SciRAP method. A total of 11 publications were selected from the 289 studies that fulfilled the inclusion criteria. The mean reporting and methodologic quality SciRAP scores were 82.7 ± 6.4/100 and 87 ± 4.2/100, respectively. Within the limitations of this in vitro systematic review, it can be concluded that the TiO2 coatings with smooth nano-structured surface topography and good wettability improve gingival cell response compared to non-coated surfaces.
Collapse
Affiliation(s)
- Nagat Areid
- Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, FI-20014 Turku, Finland
| | - Sini Riivari
- Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, FI-20014 Turku, Finland
| | - Faleh Abushahba
- Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, FI-20014 Turku, Finland
| | - Khalil Shahramian
- Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, FI-20014 Turku, Finland
- Turku Clinical Biomaterials Center (TCBC), University of Turku, FI-20014 Turku, Finland
| | - Timo Närhi
- Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, FI-20014 Turku, Finland
- Turku Clinical Biomaterials Center (TCBC), University of Turku, FI-20014 Turku, Finland
- Oral Health Care, Wellbeing services county of Southwest Finland, P.O. Box 52, FIN-20521 Turku, Finland
| |
Collapse
|
111
|
Vaiani L, Boccaccio A, Uva AE, Palumbo G, Piccininni A, Guglielmi P, Cantore S, Santacroce L, Charitos IA, Ballini A. Ceramic Materials for Biomedical Applications: An Overview on Properties and Fabrication Processes. J Funct Biomater 2023; 14:146. [PMID: 36976070 PMCID: PMC10052110 DOI: 10.3390/jfb14030146] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2023] [Revised: 02/14/2023] [Accepted: 03/02/2023] [Indexed: 03/08/2023] Open
Abstract
A growing interest in creating advanced biomaterials with specific physical and chemical properties is currently being observed. These high-standard materials must be capable to integrate into biological environments such as the oral cavity or other anatomical regions in the human body. Given these requirements, ceramic biomaterials offer a feasible solution in terms of mechanical strength, biological functionality, and biocompatibility. In this review, the fundamental physical, chemical, and mechanical properties of the main ceramic biomaterials and ceramic nanocomposites are drawn, along with some primary related applications in biomedical fields, such as orthopedics, dentistry, and regenerative medicine. Furthermore, an in-depth focus on bone-tissue engineering and biomimetic ceramic scaffold design and fabrication is presented.
Collapse
Affiliation(s)
- Lorenzo Vaiani
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Antonio Boccaccio
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Antonio Emmanuele Uva
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Gianfranco Palumbo
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Antonio Piccininni
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Pasquale Guglielmi
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Stefania Cantore
- Independent Researcher, Sorriso & Benessere-Ricerca e Clinica, 70129 Bari, Italy
| | - Luigi Santacroce
- Microbiology and Virology Unit, Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70126 Bari, Italy
| | - Ioannis Alexandros Charitos
- Emergency/Urgency Department, National Poisoning Center, Riuniti University Hospital of Foggia, 71122 Foggia, Italy
| | - Andrea Ballini
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, 80138 Naples, Italy
| |
Collapse
|
112
|
Ozkan A, Çakır DA, Tezel H, Sanajou S, Yirun A, Baydar T, Erkekoglu P. Dental Implants and Implant Coatings: A Focus on Their Toxicity and Safety. J Environ Pathol Toxicol Oncol 2023; 42:31-48. [PMID: 36749088 DOI: 10.1615/jenvironpatholtoxicoloncol.2022043467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Dental implants are medical devices that are surgically inserted into the patient's jawbone by an orthodontist to act as roots of missing teeth. After the implantation, the maxilla or mandible integrates with the surface of the dental implant. This process, called "osseointegration," is an important period to ensure the long-term use of dental implants and prevent implant failures. Metal implants are the most used implant materials. However, they have disadvantages such as corrosion, metal ion release from metal implant surfaces and associated toxicity. To avoid these adverse effects and improve osseointegration, alternative dental implant materials such as ceramics, polymers, composites, and novel surface modification technologies have been developed. The safety of these materials are also of concern for toxicologists. This review will give general information about dental implant materials, osseointegration and successful implantation process. Moreover, we will focus on the new surface coatings materials for of dental implants and their toxicity and safety concerns will be discussed.
Collapse
Affiliation(s)
- Atakan Ozkan
- TOBB University of Economics and Technology, Faculty of Engineering, Department of Biomedical Engineering, Ankara, Turkey
| | - Deniz Arca Çakır
- Hacettepe University Faculty of Pharmacy, Department of Pharmaceutical Toxicology, Ankara, Turkey; Hacettepe University Vaccine Institute, Department of Vaccinology, Ankara, Turkey
| | - Hülya Tezel
- Hacettepe University Faculty of Pharmacy, Department of Pharmaceutical Toxicology, Ankara, Turkey
| | - Sonia Sanajou
- Hacettepe University Faculty of Pharmacy, Department of Pharmaceutical Toxicology, Ankara, Turkey
| | - Anil Yirun
- Hacettepe University, Faculty of Pharmacy, Department of Pharmaceutical Toxicology, Sıhhiye 06100, Ankara, Turkey; Çukurova University, Faculty of Pharmacy, Department of Pharmaceutical Toxicology, Adana, Turkey
| | - Terken Baydar
- Hacettepe University Faculty of Pharmacy, Department of Pharmaceutical Toxicology, Ankara, Turkey
| | - Pinar Erkekoglu
- Hacettepe University, Faculty of Pharmacy, Department of Pharmaceutical Toxicology, Sıhhiye 06100, Ankara, Turkey; Hacettepe University Vaccine Institute, Department of Vaccinology, Ankara, Turkey
| |
Collapse
|
113
|
Ravidà A, Samal A, Qazi M, Webber LP, Wang HL, Galindo-Moreno P, Borgnakke WS, Saleh MHA. Interproximal implant thread exposure after initial bone remodeling as a risk indicator for peri-implantitis. J Periodontol 2022. [PMID: 36576085 DOI: 10.1002/jper.22-0499] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 11/26/2022] [Accepted: 11/26/2022] [Indexed: 12/29/2022]
Abstract
BACKGROUND Due to the clinical challenges involved in successfully treating peri-implantitis, it is imperative to identify patient- and implant-level risk factors for its prevention. The main goal of this retrospective longitudinal radiographic and clinical study was to investigate whether interproximal radiographic implant thread exposure after physiological bone remodeling may be a risk factor for peri-implantitis. The secondary goal was to evaluate several other potential risk indicators. METHODS Of 4325 active dental school patients having implants placed, 165 partially edentulous adults (77 men, 88 women) aged 30-91 with ≥2 years of follow-up upon implant restoration were included. Implants with ≥1 interproximal thread exposed (no bone-to-implant contact) (n = 98, 35%) constituted the test group and those without exposed threads (n = 182, 65%) the control group. Descriptive, binary, and multivariate regression analyses were evaluated for goodness of fit. Wald tests were used to evaluate for significance set at 0.05. RESULTS Of the 280 implants (98 test, 182 control), 8 (2.9%) failed over a mean follow-up period of 7.67 (±2.63) years, and 27 implants (19 test, 8 control) developed peri-implantitis, with the exposed group having eight-fold (7.82 times) adjusted greater odds than the non-exposed. The risk increased four-fold (3.77 times) with each thread exposed. No other patient- or implant-related potentially confounding risk factors were identified. CONCLUSIONS Exposed interproximal implant threads after physiologic bone remodeling may be an independent risk indicator for incident peri-implantitis. Hence, clinicians should closely monitor patients with implant threads that have no bone-to-implant contact for incident peri-implantitis.
Collapse
Affiliation(s)
- Andrea Ravidà
- Department of Periodontics and Preventive Dentistry, University of Pittsburgh School of Dental Medicine, Pittsburgh, Pennsylvania, USA.,Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan, USA
| | - Ankita Samal
- Department of Periodontics and Preventive Dentistry, University of Pittsburgh School of Dental Medicine, Pittsburgh, Pennsylvania, USA
| | - Musa Qazi
- Department of Periodontics and Preventive Dentistry, University of Pittsburgh School of Dental Medicine, Pittsburgh, Pennsylvania, USA
| | - Liana Preto Webber
- Department of Periodontics and Preventive Dentistry, University of Pittsburgh School of Dental Medicine, Pittsburgh, Pennsylvania, USA
| | - Hom-Lay Wang
- Department of Periodontics and Preventive Dentistry, University of Pittsburgh School of Dental Medicine, Pittsburgh, Pennsylvania, USA
| | - Pablo Galindo-Moreno
- Department of Oral Surgery and Implantology, University of Granada, Granada, Spain
| | - Wenche S Borgnakke
- Department of Periodontics and Preventive Dentistry, University of Pittsburgh School of Dental Medicine, Pittsburgh, Pennsylvania, USA
| | - Muhammad H A Saleh
- Department of Periodontics and Preventive Dentistry, University of Pittsburgh School of Dental Medicine, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
114
|
Contuzzi N, Casalino G, Boccaccio A, Ballini A, Charitos IA, Bottalico L, Santacroce L. Metals Biotribology and Oral Microbiota Biocorrosion Mechanisms. J Funct Biomater 2022; 14:14. [PMID: 36662061 PMCID: PMC9863779 DOI: 10.3390/jfb14010014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 12/13/2022] [Accepted: 12/17/2022] [Indexed: 12/28/2022] Open
Abstract
During the last decades, metal-based biomaterials have been extensively explored to be used as biocompatible metals for biomedical applications, owing to their superior mechanical properties and corrosion resistance. Consequently, for long-term implanted medical devices, to assure the biomaterials' reliability, functionality, and biocompatibility, studying the various bio-tribological damage mechanisms to obtain the optimum properties is one of the most important goals. In this review, we consider the most important metal-based biomaterials such as stainless steel, alloys of titanium (Ti), cobalt-chromium (Co-Cr), and Nichel-Titatium (Ni-Ti), as well Magnesium (Mg) alloys and with Tantalum (Ta), emphasizing their characteristics, clinical applications, and deterioration over time. The influence of metal elements on biological safety, including significant effects of metal-based biomaterials in dentistry were discussed, considering the perspectives of surface, mechanical properties, corrosion behaviors, including interactions, bio-mechanisms with tissues, and oral environments. In addition, the role of the oral microbiota was explored due to its role in this erosion condition, in order to further understand the mechanism of metal-based biomaterials implanted on the microflora balance of aerobic and anaerobic bacteria in an oral environment.
Collapse
Affiliation(s)
- Nicola Contuzzi
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Giuseppe Casalino
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Antonio Boccaccio
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Andrea Ballini
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, 80138 Naples, Italy
| | - Ioannis Alexandros Charitos
- Emergency/Urgent Department, National Poisoning Center, Riuniti University Hospital of Foggia, 71122 Foggia, Italy
| | - Lucrezia Bottalico
- Interdepartmental Research Center for Pre-Latin, Latin and Oriental Rights and Culture Studies (CEDICLO), University of Bari, 70121 Bari, Italy
| | - Luigi Santacroce
- Department of Interdisciplinary Medicine, Microbiology and Virology Unit, University of Bari “Aldo Moro”, 70126 Bari, Italy
| |
Collapse
|
115
|
Pidhatika B, Widyaya VT, Nalam PC, Swasono YA, Ardhani R. Surface Modifications of High-Performance Polymer Polyetheretherketone (PEEK) to Improve Its Biological Performance in Dentistry. Polymers (Basel) 2022; 14:polym14245526. [PMID: 36559893 PMCID: PMC9787615 DOI: 10.3390/polym14245526] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 11/17/2022] [Accepted: 11/20/2022] [Indexed: 12/23/2022] Open
Abstract
This comprehensive review focuses on polyetheretherketone (PEEK), a synthetic thermoplastic polymer, for applications in dentistry. As a high-performance polymer, PEEK is intrinsically robust yet biocompatible, making it an ideal substitute for titanium-the current gold standard in dentistry. PEEK, however, is also inert due to its low surface energy and brings challenges when employed in dentistry. Inert PEEK often falls short of achieving a few critical requirements of clinical dental materials, such as adhesiveness, osseoconductivity, antibacterial properties, and resistance to tribocorrosion. This study aims to review these properties and explore the various surface modification strategies that enhance the performance of PEEK. Literatures searches were conducted on Google Scholar, Research Gate, and PubMed databases using PEEK, polyetheretherketone, osseointegration of PEEK, PEEK in dentistry, tribology of PEEK, surface modifications, dental applications, bonding strength, surface topography, adhesive in dentistry, and dental implant as keywords. Literature on the topics of surface modification to increase adhesiveness, tribology, and osseointegration of PEEK were included in the review. The unavailability of full texts was considered when excluding literature. Surface modifications via chemical strategies (such as sulfonation, plasma treatment, UV treatment, surface coating, surface polymerization, etc.) and/or physical approaches (such as sandblasting, laser treatment, accelerated neutral atom beam, layer-by-layer assembly, particle leaching, etc.) discussed in the literature are summarized and compared. Further, approaches such as the incorporation of bioactive materials, e.g., osteogenic agents, antibacterial agents, etc., to enhance the abovementioned desired properties are explored. This review presents surface modification as a critical and essential approach to enhance the biological performance of PEEK in dentistry by retaining its mechanical robustness.
Collapse
Affiliation(s)
- Bidhari Pidhatika
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia
- Collaborative Research Center for Biomedical Scaffolds, National Research and Innovation Agency of the Republic Indonesia and Universitas Gadjah Mada, Jalan Denta No. 1, Sekip Utara, Yogyakarta 55281, Indonesia
| | - Vania Tanda Widyaya
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia
| | - Prathima C. Nalam
- Department of Materials Design and Innovation, University at Buffalo, Buffalo, NY 14260-1900, USA
| | - Yogi Angga Swasono
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia
| | - Retno Ardhani
- Department of Dental Biomedical Science, Faculty of Dentistry, Universitas Gadjah Mada, Jalan Denta No. 1, Sekip Utara, Yogyakarta 55281, Indonesia
- Correspondence:
| |
Collapse
|
116
|
Advances in sustainable grinding of different types of the titanium biomaterials for medical applications: A review. BIOMEDICAL ENGINEERING ADVANCES 2022. [DOI: 10.1016/j.bea.2022.100047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
117
|
Shirazi S, Ravindran S, Cooper LF. Topography-mediated immunomodulation in osseointegration; Ally or Enemy. Biomaterials 2022; 291:121903. [PMID: 36410109 PMCID: PMC10148651 DOI: 10.1016/j.biomaterials.2022.121903] [Citation(s) in RCA: 48] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 11/02/2022] [Accepted: 11/04/2022] [Indexed: 11/11/2022]
Abstract
Osteoimmunology is at full display during endosseous implant osseointegration. Bone formation, maintenance and resorption at the implant surface is a result of bidirectional and dynamic reciprocal communication between the bone and immune cells that extends beyond the well-defined osteoblast-osteoclast signaling. Implant surface topography informs adherent progenitor and immune cell function and their cross-talk to modulate the process of bone accrual. Integrating titanium surface engineering with the principles of immunology is utilized to harness the power of immune system to improve osseointegration in healthy and diseased microenvironments. This review summarizes current information regarding immune cell-titanium implant surface interactions and places these events in the context of surface-mediated immunomodulation and bone regeneration. A mechanistic approach is directed in demonstrating the central role of osteoimmunology in the process of osseointegration and exploring how regulation of immune cell function at the implant-bone interface may be used in future control of clinical therapies. The process of peri-implant bone loss is also informed by immunomodulation at the implant surface. How surface topography is exploited to prevent osteoclastogenesis is considered herein with respect to peri-implant inflammation, osteoclastic precursor-surface interactions, and the upstream/downstream effects of surface topography on immune and progenitor cell function.
Collapse
Affiliation(s)
- Sajjad Shirazi
- Department of Oral Biology, College of Dentistry, University of Illinois Chicago, Chicago, IL, USA.
| | - Sriram Ravindran
- Department of Oral Biology, College of Dentistry, University of Illinois Chicago, Chicago, IL, USA
| | - Lyndon F Cooper
- School of Dentistry, Virginia Commonwealth University, Richmond, VA, USA.
| |
Collapse
|
118
|
Chen C, Huang B, Liu Y, Liu F, Lee IS. Functional engineering strategies of 3D printed implants for hard tissue replacement. Regen Biomater 2022; 10:rbac094. [PMID: 36683758 PMCID: PMC9845531 DOI: 10.1093/rb/rbac094] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 10/20/2022] [Accepted: 10/27/2022] [Indexed: 11/27/2022] Open
Abstract
Three-dimensional printing technology with the rapid development of printing materials are widely recognized as a promising way to fabricate bioartificial bone tissues. In consideration of the disadvantages of bone substitutes, including poor mechanical properties, lack of vascularization and insufficient osteointegration, functional modification strategies can provide multiple functions and desired characteristics of printing materials, enhance their physicochemical and biological properties in bone tissue engineering. Thus, this review focuses on the advances of functional engineering strategies for 3D printed biomaterials in hard tissue replacement. It is structured as introducing 3D printing technologies, properties of printing materials (metals, ceramics and polymers) and typical functional engineering strategies utilized in the application of bone, cartilage and joint regeneration.
Collapse
Affiliation(s)
- Cen Chen
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou 310018, PR China
| | - Bo Huang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou 310018, PR China
| | - Yi Liu
- Department of Orthodontics, School of Stomatology, China Medical University, Shenyang 110002, PR China
| | - Fan Liu
- Department of Orthodontics, School of Stomatology, China Medical University, Shenyang 110002, PR China
| | | |
Collapse
|
119
|
Martinez-Mondragon M, Urriolagoitia-Sosa G, Romero-Ángeles B, Maya-Anaya D, Martínez-Reyes J, Gallegos-Funes FJ, Urriolagoitia-Calderón GM. Numerical Analysis of Zirconium and Titanium Implants under the Effect of Critical Masticatory Load. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7843. [PMID: 36363435 PMCID: PMC9657110 DOI: 10.3390/ma15217843] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 10/14/2022] [Accepted: 11/01/2022] [Indexed: 06/16/2023]
Abstract
Dental implants have become an alternative to replace the teeth of people suffering from edentulous and meet the physiological and morphological characteristics (recovering 95% of the chewing function). The evolution and innovation of biomaterials for dental implants have had a trajectory that dates back to prehistory, where dental pieces were replaced by ivory or seashells, to the present day, where they are replaced by metallic materials such as titanium or ceramics such as zirconium or fiberglass. The numerical evaluation focuses on comparing the stress distribution and general displacement between different dental implants and a healthy tooth when applying a force of 850 N. For the analysis, a model of the anatomical structure was developed of a healthy tooth considering three essential parts of the tooth (enamel, dentin, and pulp). The tooth biomodel was established through computed tomography. Three dental implant models were considered by changing the geometry of the abutment. A structural simulation was carried out by applying the finite element method (FEM). In addition, the material considered for the analyses was zirconium oxide (ZrO2), which was compared against titanium alloy (Ti6Al4V). The analyses were considered with linear, isotropic, and homogeneous properties. The variables included in the biomodeling were the modulus of elasticity, Poisson's ratio, density, and elastic limit. The results obtained from the study indicated a significant difference in the biomechanical behavior of the von Mises forces and the displacement between the healthy tooth and the titanium and zirconium implant models. However, the difference between the titanium implant and the zirconium implant is minimal because one is more rigid, and the other is more tenacious.
Collapse
|
120
|
Wang S, Wu Z, Wang Y, Hong H, Zhang L, Chen Z, Zhang P, Chen Z, Zhang W, Zheng S, Li Q, Li W, Li X, Qiu H, Chen J. A homogeneous dopamine-silver nanocomposite coating: striking a balance between the antibacterial ability and cytocompatibility of dental implants. Regen Biomater 2022; 10:rbac082. [PMID: 36683759 PMCID: PMC9847628 DOI: 10.1093/rb/rbac082] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2022] [Revised: 09/30/2022] [Accepted: 10/11/2022] [Indexed: 01/25/2023] Open
Abstract
Silver has been widely used for surface modification to prevent implant-associated infections. However, the inherent cytotoxicity of silver greatly limited the scope of its clinical applications. The construction of surfaces with both good antibacterial properties and favorable cytocompatibility still remains a challenge. In this study, a structurally homogeneous dopamine-silver (DA/Ag) nanocomposite was fabricated on the implant surface to balance the antibacterial activity and cytocompatibility of the implant. The results show that the DA/Ag nanocomposites prepared under the acidic conditions (pH = 4) on the titanium surface are homogeneous with higher Ag+ content, while an obvious core (AgNPs)-shell (PDA) structure is formed under neutral (pH = 7) and alkaline conditions (pH = 10), and the subsequent heat treatment enhanced the stability of PDA-AgNPs nanocomposite coatings on porous titanium. The antibacterial test, cytotoxicity test, hypodermic implantation and osteogenesis test revealed that the homogeneous PDA-AgNPs nanocomposite coating achieved the balance between the antibacterial ability and cytocompatibility, and had the best outcomes for soft tissue healing and bone formation around the implants. This study provides a facile strategy for preparing silver-loaded surfaces with both good antibacterial effect and favorable cytocompatibility, which is expected to further improve the therapeutic efficacy of silver composite-coated dental implants.
Collapse
Affiliation(s)
| | | | | | - Huilei Hong
- Key Laboratory of Oral Diseases Research of Anhui Province, Stomatologic Hospital and College, Anhui Medical University, Hefei, Anhui 230032, China
| | - Lijie Zhang
- Key Laboratory of Oral Diseases Research of Anhui Province, Stomatologic Hospital and College, Anhui Medical University, Hefei, Anhui 230032, China
| | - Zhaoyang Chen
- Key Laboratory of Oral Diseases Research of Anhui Province, Stomatologic Hospital and College, Anhui Medical University, Hefei, Anhui 230032, China
| | - Pengkang Zhang
- Key Laboratory of Oral Diseases Research of Anhui Province, Stomatologic Hospital and College, Anhui Medical University, Hefei, Anhui 230032, China
| | - Zirui Chen
- Key Laboratory of Oral Diseases Research of Anhui Province, Stomatologic Hospital and College, Anhui Medical University, Hefei, Anhui 230032, China
| | - Weibo Zhang
- Key Laboratory of Oral Diseases Research of Anhui Province, Stomatologic Hospital and College, Anhui Medical University, Hefei, Anhui 230032, China
| | - Shunli Zheng
- Key Laboratory of Oral Diseases Research of Anhui Province, Stomatologic Hospital and College, Anhui Medical University, Hefei, Anhui 230032, China
| | - Quanli Li
- Key Laboratory of Oral Diseases Research of Anhui Province, Stomatologic Hospital and College, Anhui Medical University, Hefei, Anhui 230032, China
| | - Wei Li
- Correspondence address. E-mail: (W.L.); (H.Q.); (X.L.); (J.C.)
| | - Xiangyang Li
- Correspondence address. E-mail: (W.L.); (H.Q.); (X.L.); (J.C.)
| | - Hua Qiu
- Correspondence address. E-mail: (W.L.); (H.Q.); (X.L.); (J.C.)
| | - Jialong Chen
- Correspondence address. E-mail: (W.L.); (H.Q.); (X.L.); (J.C.)
| |
Collapse
|
121
|
Hasan J, Bright R, Hayles A, Palms D, Zilm P, Barker D, Vasilev K. Preventing Peri-implantitis: The Quest for a Next Generation of Titanium Dental Implants. ACS Biomater Sci Eng 2022; 8:4697-4737. [PMID: 36240391 DOI: 10.1021/acsbiomaterials.2c00540] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Titanium and its alloys are frequently the biomaterial of choice for dental implant applications. Although titanium dental implants have been utilized for decades, there are yet unresolved issues pertaining to implant failure. Dental implant failure can arise either through wear and fatigue of the implant itself or peri-implant disease and subsequent host inflammation. In the present report, we provide a comprehensive review of titanium and its alloys in the context of dental implant material, and how surface properties influence the rate of bacterial colonization and peri-implant disease. Details are provided on the various periodontal pathogens implicated in peri-implantitis, their adhesive behavior, and how this relationship is governed by the implant surface properties. Issues of osteointegration and immunomodulation are also discussed in relation to titanium dental implants. Some impediments in the commercial translation for a novel titanium-based dental implant from "bench to bedside" are discussed. Numerous in vitro studies on novel materials, processing techniques, and methodologies performed on dental implants have been highlighted. The present report review that comprehensively compares the in vitro, in vivo, and clinical studies of titanium and its alloys for dental implants.
Collapse
Affiliation(s)
- Jafar Hasan
- Academic Unit of STEM, University of South Australia, Mawson Lakes, SA 5095, Australia
| | - Richard Bright
- Academic Unit of STEM, University of South Australia, Mawson Lakes, SA 5095, Australia.,College of Medicine and Public Health, Flinders University, Bedford Park 5042, South Australia, Australia
| | - Andrew Hayles
- Academic Unit of STEM, University of South Australia, Mawson Lakes, SA 5095, Australia.,College of Medicine and Public Health, Flinders University, Bedford Park 5042, South Australia, Australia
| | - Dennis Palms
- Academic Unit of STEM, University of South Australia, Mawson Lakes, SA 5095, Australia.,College of Medicine and Public Health, Flinders University, Bedford Park 5042, South Australia, Australia
| | - Peter Zilm
- Adelaide Dental School, University of Adelaide, Adelaide, 5005, South Australia, Australia
| | - Dan Barker
- ANISOP Holdings, Pty. Ltd., 101 Collins St, Melbourne VIC, 3000 Australia
| | - Krasimir Vasilev
- Academic Unit of STEM, University of South Australia, Mawson Lakes, SA 5095, Australia.,College of Medicine and Public Health, Flinders University, Bedford Park 5042, South Australia, Australia
| |
Collapse
|
122
|
He F, Li J, Wang Y, Li Z, Wang L, Li Y, Chen H, Wang C, Liu B, Ma P, Dong G, Zhou P. Design of Cefotaxime Sodium-Loaded Polydopamine Coatings with Controlled Surface Roughness for Titanium Implants. ACS Biomater Sci Eng 2022; 8:4751-4763. [PMID: 36191062 DOI: 10.1021/acsbiomaterials.2c00702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The success rate of dental implants is limited by peri-implant infection and insufficient osseointegration. Therefore, reducing the occurrence of peri-implantitis and promoting osseointegration are in demand. A roughened surface has commonly been applied to improve the osseointegration of implants, but it will accelerate the attachment of bacteria. We have developed novel antibiotic-decorated titanium (Ti) surfaces by the immobilization of dopamine and cefotaxime sodium (CS) simultaneously. Moreover, the surface roughness of the polydopamine (PDA)/CS coating was controlled by the changes in polymerization times as determined by atomic force microscopy. Then, all antibiotic-grafted Ti surfaces could effectively prevent the adhesion and proliferation of both Escherichia coli and Streptococcus mutans in comparison to the pristine control. For the culture and osteogenic differentiation of human umbilical mesenchymal stem cells (hUMSCs) on the substrate surface, PDA/CS coating with polymerization times less than 30 min showed acceptable biocompatibility, but the upregulation of marker genes and proteins was detected when the polymerization time was more than 30 min. Moreover, the best calcium deposition results were found in the 30 min PDA/CS group with or without the addition of osteogenic factors. Therefore, our PDA/CS coating with a polymerization time of 30 min holds great potential to design dental implants with dual bacteriostatic and osteogenic properties.
Collapse
Affiliation(s)
- Fei He
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China.,Key Laboratory of Mechanics on Disaster and Environment in Western China, Ministry of Education, College of Civil Engineering and Mechanics, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Jing Li
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Yixi Wang
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Zhipeng Li
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Lu Wang
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Yuchen Li
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Huiling Chen
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Chenggang Wang
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Bin Liu
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Peng Ma
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Genxi Dong
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Ping Zhou
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China.,Department of Orthopedics, Lanzhou University Second Hospital, No. 82 Cuiyingmen Street, Lanzhou 730030, Gansu, P. R. China
| |
Collapse
|
123
|
Alves CH, Russi KL, Rocha NC, Bastos F, Darrieux M, Parisotto TM, Girardello R. Host-microbiome interactions regarding peri-implantitis and dental implant loss. Lab Invest 2022; 20:425. [PMID: 36138430 PMCID: PMC9502891 DOI: 10.1186/s12967-022-03636-9] [Citation(s) in RCA: 48] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Accepted: 09/12/2022] [Indexed: 11/16/2022]
Abstract
In the last decades, the ortho-aesthetic-functional rehabilitation had significant advances with the advent of implantology. Despite the success in implantology surgeries, there is a percentage of failures mainly due to in loco infections, through bacterial proliferation, presence of fungi and biofilm formation, originating peri-implantitis. In this sense, several studies have been conducted since then, seeking answers to numerous questions that remain unknown. Thus, the present work aims to discuss the interaction between host-oral microbiome and the development of peri-implantitis. Peri-implantitis was associated with a diversity of bacterial species, being Porphiromonas gingivalis, Treponema denticola and Tannerella forsythia described in higher proportion of peri-implantitis samples. In a parallel role, the injury of peri-implant tissue causes an inflammatory response mediated by activation of innate immune cells such as macrophages, dendritic cells, mast cells, and neutrophils. In summary, the host immune system activation may lead to imbalance of oral microbiota, and, in turn, the oral microbiota dysbiosis is reported leading to cytokines, chemokines, prostaglandins, and proteolytic enzymes production. These biological processes may be responsible for implant loss.
Collapse
Affiliation(s)
- Carlos Henrique Alves
- Laboratório de Microbiologia Molecular E Clínica, Programa de Pós-Graduação Em Ciências da Saúde, Universidade São Francisco, 218, São Francisco Ave., Bragança Paulista, São Paulo, Zip code: # 12916900, Brazil
| | - Karolayne Larissa Russi
- Laboratório de Microbiologia Molecular E Clínica, Programa de Pós-Graduação Em Ciências da Saúde, Universidade São Francisco, 218, São Francisco Ave., Bragança Paulista, São Paulo, Zip code: # 12916900, Brazil
| | - Natália Conceição Rocha
- Laboratório de Microbiologia Molecular E Clínica, Programa de Pós-Graduação Em Ciências da Saúde, Universidade São Francisco, 218, São Francisco Ave., Bragança Paulista, São Paulo, Zip code: # 12916900, Brazil
| | | | - Michelle Darrieux
- Laboratório de Microbiologia Molecular E Clínica, Programa de Pós-Graduação Em Ciências da Saúde, Universidade São Francisco, 218, São Francisco Ave., Bragança Paulista, São Paulo, Zip code: # 12916900, Brazil
| | - Thais Manzano Parisotto
- Laboratório de Microbiologia Molecular E Clínica, Programa de Pós-Graduação Em Ciências da Saúde, Universidade São Francisco, 218, São Francisco Ave., Bragança Paulista, São Paulo, Zip code: # 12916900, Brazil
| | - Raquel Girardello
- Laboratório de Microbiologia Molecular E Clínica, Programa de Pós-Graduação Em Ciências da Saúde, Universidade São Francisco, 218, São Francisco Ave., Bragança Paulista, São Paulo, Zip code: # 12916900, Brazil.
| |
Collapse
|
124
|
Glauser R, Schupbach P. Early bone formation around immediately placed two-piece tissue-level zirconia implants with a modified surface: an experimental study in the miniature pig mandible. Int J Implant Dent 2022; 8:37. [PMID: 36103094 PMCID: PMC9474793 DOI: 10.1186/s40729-022-00437-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Accepted: 09/08/2022] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To histologically examine early bone formation around transmucosal implants and to evaluate the influence of surface characteristics on early peri-implant bone healing using a miniature pig model. For this, commercially available dental implants with a rough zirconia (YTZP) surface were compared to surface-modified Ti control implants at 4 and 8 weeks after placement. METHODS Immediately following the extraction of six mandibular premolars, 20 two-piece, tissue-level, screw-shaped YTZP implants (Patent™ Standard Zirconia Implant ø4.1 × 11 mm) with a modified rough blasted before sintering surface were inserted in four adult miniature pigs. In addition, four titanium (Ti) tissue-level implants (Straumann® Standard RN ø4.1 × 10 mm Roxolid®) with a moderate surface (SLActive®), one per animal, were placed as control implants. A histological analysis was performed on the hard tissues after 4 and 8 weeks of transmucosal healing. RESULTS The results show a high rate of osseointegration of the test YTZP dental implants at 4 and 8 weeks following insertion. At 4 weeks, a bone-to-implant contact ratio (BIC) of 73.7% (SD ± 16.8) for the test implants (n = 10) and 58.5% for the first control implant was achieved. The second control implant had to be excluded from analysis. At 8 weeks, a BIC of 82.4% (SD ± 16.9) for the test implants (n = 9) and 93.6% (SD ± 9.1) (n = 2) for the control implant was achieved. No statistical difference was observed comparing 4 and 8 weeks YTZP data (p = 0.126). CONCLUSIONS The results indicate a predictable osseointegration of immediate zirconia implants with a modified YTZP implant surface and a high degree of BIC present at 4 weeks following insertion. After 8 weeks of healing both the zirconia implants and the Ti implants show a BIC indicating full osseointegration. Further studies involving a larger sample size with more time points are needed to confirm these results.
Collapse
Affiliation(s)
| | - Peter Schupbach
- Schupbach Ltd, Histology and Electron Microscopy, Thalwil, Switzerland.
| |
Collapse
|
125
|
Effects of Different Titanium Surface Treatments on Adhesion, Proliferation and Differentiation of Bone Cells: An In Vitro Study. J Funct Biomater 2022; 13:jfb13030143. [PMID: 36135578 PMCID: PMC9503392 DOI: 10.3390/jfb13030143] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 08/31/2022] [Accepted: 09/01/2022] [Indexed: 11/17/2022] Open
Abstract
The objective of this study was to evaluate the impacts of different sandblasting procedures in acid etching of Ti6Al4V surfaces on osteoblast cell behavior, regarding various physicochemical and topographical parameters. Furthermore, differences in osteoblast cell behavior between cpTi and Ti6Al4V SA surfaces were evaluated. Sandblasting and subsequent acid etching of cpTi and Ti6Al4V discs was performed with Al2O3 grains of different sizes and with varying blasting pressures. The micro- and nano-roughness of the experimental SA surfaces were analyzed via confocal, atomic force and scanning electron microscopy. Surface free energy and friction coefficients were determined. hFOB 1.19 cells were seeded to evaluate adhesion, proliferation and osteoblastic differentiation for up to 12 d via crystal violet assays, MTT assays, ALP activity assays and Alizarin Red staining assays. Differences in blasting procedures had significant impacts on surface macro- and micro-topography. The crystal violet assay revealed a significant inverse relationship between blasting grain size and hFOB cell growth after 7 days. This trend was also visible in the Alizarin Red assays staining after 12 d: there was significantly higher biomineralization visible in the group that was sandblasted with smaller grains (F180) when compared to standard-grain-size groups (F70). SA samples treated with reduced blasting pressure exhibited lower hFOB adhesion and growth capabilities at initial (2 h) and later time points for up to 7 days, when compared to the standard SA surface, even though micro-roughness and other relevant surface parameters were similar. Overall, etched-only surfaces consistently exhibited equivalent or higher adhesion, proliferation and differentiation capabilities when compared to all other sandblasted and etched surfaces. No differences were found between cpTi and Ti6Al4V SA surfaces. Subtle modifications in the blasting protocol for Ti6Al4V SA surfaces significantly affect the proliferative and differentiation behavior of human osteoblasts. Surface roughness parameters are not sufficient to predict osteoblast behavior on etched Ti6Al4V surfaces.
Collapse
|
126
|
Formation of Oxide Layer and Wettability on the Surface of Electrical Discharge Machining-Based Implant Engineered by Micro-Finishing. JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING 2022. [DOI: 10.4028/p-8u998r] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The ability to promote rapid osseointegration is an important criterion on the titanium implant surface. This performance is greatly determined by the roughness, wettability, and composition of the implant surface. This study aims to investigate the oxide layer formation and wettability on the EDM-titanium implant surface engineered by different micro-finishing methods (i.e. mechanical, physical, and chemical processes). The oxide layer formation was investigated by observing the wt% of oxygen formed while the wettability criterion was studied by determining the contact angle between the liquid and solid surface. The result reveals that the oxide layers formed on the sample surface, excepting Sulfuric acid (H2SO4) 95%-etched, show an interaction with the surface roughness and its wettability. The smoother the surface roughness of the sample, the lower the percentage of the oxide layer and the contact angle formed on the sample surface. In this aspect, the ultrasonic cleaning benchmark has the highest percentage by altering 18.84% of the oxide layer formed by the EDM process while the decrease of 75.89% generated by the H2SO4-etching is the lowest one. On the other hand, the higher the percentage of the oxide layer formation, the lower the wettability of the sample surface. In this aspect, the ultrasonic cleaning benchmark has the lowest wettability with a contact angle of 124º (hydrophilic) while HCl-etching is the lowest with 45º (hydrophobic). The results are notable that the ultrasonic cleaning method is able to alter wt% of the oxygen on the EDM-titanium implant surface, whereas the acid etching method can be recommended as a worthy method of the surface finishing for the semi-permanent type of implant.
Collapse
|
127
|
Fabbri G, Staas T, Urban I. A Retrospective Observational Study Assessing the Clinical Outcomes of a Novel Implant System with Low-Speed Site Preparation Protocol and Tri-Oval Implant Geometry. J Clin Med 2022; 11:jcm11164859. [PMID: 36013098 PMCID: PMC9410172 DOI: 10.3390/jcm11164859] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 08/09/2022] [Accepted: 08/16/2022] [Indexed: 11/16/2022] Open
Abstract
A novel, biologically friendly implant concept system introduces low-speed (50 rpm) site preparation instruments used without irrigation and a tri-oval, tapered implant designed to reduce stress on cortical bone without sacrificing mechanical stability. This retrospective, observational, multicenter study (clinicaltrials.gov NCT04736771) collected data from consecutive patients treated with at least one novel concept system implant to evaluate clinical outcomes after 1 year in function. The primary endpoint was a marginal bone level change (MBLC) from loading to 1 year, and secondary endpoints included implant survival and clinician feedback. Ninety-five patients (54 women and 41 men, mean age: 58 ± 12 years) were treated with 165 implants. For 94.5% of implants, site preparation was performed in two steps. The mean follow-up from implant insertion was 1.8 ± 0.2 years. Mean MBLC from implant loading to 1-year follow-up was +0.15 ± 0.85 mm (n = 124 implants). At the last follow-up, the implant survival rate was 98.0%. Clinician satisfaction with the novel concept system was high. The novel concept system offers an easy-to-use implant placement protocol, with most implants placed using two steps. The minimal bone remodeling and high survival rate observed across a variety of indications and treatment protocols demonstrate broad versatility and confirm the clinical benefits of this biologically friendly innovation.
Collapse
Affiliation(s)
- Giacomo Fabbri
- Studio Odontoiatrico Specialistico Ban Mancini Fabbri, Via del Porto 17, 47841 Cattolica, Italy
- Correspondence:
| | - Tristan Staas
- Staas & Bergmans, Schubertsingel 32, 5216 XA ‘s-Hertogenbosch, The Netherlands
| | - Istvan Urban
- Urban Dental Center Kft, Pitypang Street 7, 1025 Budapest, Hungary
| |
Collapse
|
128
|
Influence of Magnesium Content on the Physico-Chemical Properties of Hydroxyapatite Electrochemically Deposited on a Nanostructured Titanium Surface. COATINGS 2022. [DOI: 10.3390/coatings12081097] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
The aim of this research was to obtain hydroxyapatite (HAp)-based coatings doped with different concentrations of Mg on a Ti nanostructured surface through electrochemical techniques and to evaluate the influence of Mg content on the properties of HAp. The undoped and doped HAp-based coatings were electrochemically deposited in galvanostatic pulsed mode on titania nanotubes with a diameter of ~72 nm, being designed to enhance the adhesion of the HAp coatings to the Ti substrate. The obtained materials were investigated by Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), X-Ray Diffraction (XRD), and Fourier-Transform Infra-Red spectroscopy (FTIR). The adhesion of the coatings to the substrate was also evaluated with the help of the “tape-test” and the micro-scratch test. The morphology (SEM) of all the coatings is made of very thin and narrow ribbon-like crystals, with some alterations with respect to the Mg amount in the coatings. Thus, a concentration of 1 mM of Mg in the electrolyte leads to wider and thicker ribbon-like crystals, while a concentration of 1.5 mM in the electrolyte generated a morphology that resembles the undoped HAp. Both phase composition (XRD) and chemical bonds (FTIR) analysis proved the formation of HAp in all coatings. Moreover, according to XRD, all coatings have a strong orientation toward the (002) plane. Irrespective of the Mg content, all coatings registered an average roughness between approx. 500 and 600 nm, while the coating thickness increased after addition of Mg, from a value of 9.6 μm, for the undoped HAp, to 11.3 μm and ~13.7 μm for H/Mg1 and H/Mg2, respectively. In terms of adhesion, it was shown that the coatings a H/Mg2 had a poorer adhesion when compared to H/Mg1 and the undoped HAp (H), which registered similar adhesion, indicating that a concentration of 1.5 mM of Mg in the electrolyte reduces the adhesion of the Hap-based coatings to the nanostructured surface. The obtained results indicated that Mg concentrations up to 1 mM in the electrolyte can enhance the properties of HAp-based coatings electrochemically deposited on a nanostructured surface, while even a slightly higher concentration of 1.5 mM can negatively impact the characteristics of HAp coatings.
Collapse
|
129
|
Influence of the Surface Chemical Composition Differences between Zirconia and Titanium with the Similar Surface Structure and Roughness on Bone Formation. NANOMATERIALS 2022; 12:nano12142478. [PMID: 35889704 PMCID: PMC9324478 DOI: 10.3390/nano12142478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 07/05/2022] [Accepted: 07/13/2022] [Indexed: 02/04/2023]
Abstract
The osseointegration of zirconia (ZrO2) implants is still controversial. In this study, we aimed to make clear the influence of surface chemical composition, Ti or ZrO2, to osseointegration. First, a roughened Ti surface was prepared with a combination of large-grit sandblasting and acid treatment. Then, we applied molecular precursor solution containing Zr complex onto roughened Ti surface and can deposit thin ZrO2 film onto roughened Ti surface. We can change surface chemical composition from Ti to ZrO2 without changing the surface structure and roughness of roughened Ti. The tetragonal Zr was uniformly present on the ZrO2-coated Ti surface, and the surface of the ZrO2-coated Ti showed a higher apparent zeta potential than Ti. Ti and ZrO2-coated Ti rectangular plate implant was placed into the femur bone defect. After 2 and 4 weeks of implantation, histomorphometric observation revealed that the bone-to-implant contact ratio and the bone mass values for ZrO2-coated Ti implants inserted into the femur bone defects of the rats at 2 weeks were significantly higher than those for Ti implants (p < 0.05). It revealed that ZrO2 with a similar surface structure and roughness as that of roughened Ti promoted osteogenesis equivalent to or better than that of Ti in the early bone formation stage.
Collapse
|
130
|
Tchinda A, Chézeau L, Pierson G, Kouitat-Njiwa R, Rihn BH, Bravetti P. Biocompatibility of ZrO2 vs. Y-TZP Alloys: Influence of Their Composition and Surface Topography. MATERIALS 2022; 15:ma15134655. [PMID: 35806779 PMCID: PMC9267226 DOI: 10.3390/ma15134655] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 06/21/2022] [Accepted: 06/29/2022] [Indexed: 12/04/2022]
Abstract
The osseointegration of implants is defined as the direct anatomical and functional connection between neoformed living bone and the surface of a supporting implant. The biological compatibility of implants depends on various parameters, such as the nature of the material, chemical composition, surface topography, chemistry and loading, surface treatment, and physical and mechanical properties. In this context, the objective of this study is to evaluate the biocompatibility of rough (Ra = 1 µm) and smooth (Ra = 0 µm) surface conditions of yttria–zirconia (Y-TZP) discs compared to pure zirconia (ZrO2) discs by combining a classical toxicological test, morphological observations by SEM, and a transcriptomic analysis on an in vitro model of human Saos-2 bone cells. Similar cell proliferation rates were observed between ZrO2 and Y-TZP discs and control cells, regardless of the surface topography, at up to 96 h of exposure. Dense cell matting was similarly observed on the surfaces of both materials. Interestingly, only 110 transcripts were differentially expressed across the human transcriptome, consistent with the excellent biocompatibility of Y-TZP reported in the literature. These deregulated transcripts are mainly involved in two pathways, the first being related to “mineral uptake” and the second being the “immune response”. These observations suggest that Y-TZP is an interesting candidate for application in implantology.
Collapse
|
131
|
Abstract
Bioactive coatings are widely used and understood materials in engineering [...]
Collapse
|
132
|
Cruz MB, Silva N, Marques JF, Mata A, Silva FS, Caramês J. Biomimetic Implant Surfaces and Their Role in Biological Integration-A Concise Review. Biomimetics (Basel) 2022; 7:74. [PMID: 35735590 PMCID: PMC9220941 DOI: 10.3390/biomimetics7020074] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 05/25/2022] [Accepted: 05/27/2022] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND The increased use of dental implants in oral rehabilitation has been followed by the development of new biomaterials as well as improvements in the performance of biomaterials already in use. This triggers the need for appropriate analytical approaches to assess the biological and, ultimately, clinical benefits of these approaches. AIMS To address the role of physical, chemical, mechanical, and biological characteristics in order to determine the critical parameters to improve biological responses and the long-term effectiveness of dental implant surfaces. DATA SOURCES AND METHODS Web of Science, MEDLINE and Lilacs databases were searched for the last 30 years in English, Spanish and Portuguese idioms. RESULTS Chemical composition, wettability, roughness, and topography of dental implant surfaces have all been linked to biological regulation in cell interactions, osseointegration, bone tissue and peri-implant mucosa preservation. CONCLUSION Techniques involving subtractive and additive methods, especially those involving laser treatment or embedding of bioactive nanoparticles, have demonstrated promising results. However, the literature is heterogeneous regarding study design and methodology, which limits comparisons between studies and the definition of the critical determinants of optimal cell response.
Collapse
Affiliation(s)
- Mariana Brito Cruz
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Rua Professora Teresa Ambrósio, 1600-277 Lisboa, Portugal; (J.F.M.); (A.M.)
| | - Neusa Silva
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), LIBPhys-FTC UID/FIS/04559/2013, Rua Professora Teresa Ambrósio, 1600-277 Lisboa, Portugal;
| | - Joana Faria Marques
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Rua Professora Teresa Ambrósio, 1600-277 Lisboa, Portugal; (J.F.M.); (A.M.)
| | - António Mata
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Rua Professora Teresa Ambrósio, 1600-277 Lisboa, Portugal; (J.F.M.); (A.M.)
- Cochrane Portugal, Instituto de Saúde Baseada na Evidência (ISBE), Faculdade de Medicina Dentária, Universidade de Lisboa, Avenida Professor Egas Moniz, 1649-028 Lisboa, Portugal
| | - Felipe Samuel Silva
- Center for Microelectromechanical Systems (CMEMS), Department of Mechanical Engineering, University of Minho, 4800-058 Guimarães, Portugal;
| | - João Caramês
- Bone Physiology Research Group, Faculdade de Medicina Dentária, Universidade de Lisboa, Rua Professora Teresa Ambrósio, 1600-277 Lisboa, Portugal;
| |
Collapse
|
133
|
Hernandez JL, Woodrow KA. Medical Applications of Porous Biomaterials: Features of Porosity and Tissue-Specific Implications for Biocompatibility. Adv Healthc Mater 2022; 11:e2102087. [PMID: 35137550 PMCID: PMC9081257 DOI: 10.1002/adhm.202102087] [Citation(s) in RCA: 70] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 12/17/2021] [Indexed: 12/14/2022]
Abstract
Porosity is an important material feature commonly employed in implants and tissue scaffolds. The presence of material voids permits the infiltration of cells, mechanical compliance, and outward diffusion of pharmaceutical agents. Various studies have confirmed that porosity indeed promotes favorable tissue responses, including minimal fibrous encapsulation during the foreign body reaction (FBR). However, increased biofilm formation and calcification is also described to arise due to biomaterial porosity. Additionally, the relevance of host responses like the FBR, infection, calcification, and thrombosis are dependent on tissue location and specific tissue microenvironment. In this review, the features of porous materials and the implications of porosity in the context of medical devices is discussed. Common methods to create porous materials are also discussed, as well as the parameters that are used to tune pore features. Responses toward porous biomaterials are also reviewed, including the various stages of the FBR, hemocompatibility, biofilm formation, and calcification. Finally, these host responses are considered in tissue specific locations including the subcutis, bone, cardiovascular system, brain, eye, and female reproductive tract. The effects of porosity across the various tissues of the body is highlighted and the need to consider the tissue context when engineering biomaterials is emphasized.
Collapse
Affiliation(s)
- Jamie L Hernandez
- Department of Bioengineering, University of Washington, 3720 15th Ave NE, Seattle, WA, 98195, USA
| | - Kim A Woodrow
- Department of Bioengineering, University of Washington, 3720 15th Ave NE, Seattle, WA, 98195, USA
| |
Collapse
|
134
|
Wang JJ, Xue Q, Wang YJ, Zhang M, Chen YJ, Zhang Q. Engineered Chimeric Peptides with IGF-1 and Titanium-Binding Functions to Enhance Osteogenic Differentiation In Vitro under T2DM Condition. MATERIALS 2022; 15:ma15093134. [PMID: 35591468 PMCID: PMC9105221 DOI: 10.3390/ma15093134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 03/30/2022] [Accepted: 04/24/2022] [Indexed: 02/06/2023]
Abstract
Due to the complexity of the biomolecules and titanium (Ti) combination, it is a challenge to modify the implant surface with biological cytokines. The study proposed a new method for immobilizing cytokines on implant surface to solve the problem of low osseointegration under type 2 diabetes mellitus (T2DM) condition. This new modified protein that connected Ti-binding artificial aptamer minTBP-1 with Insulin-like growth factor I (IGF-I), had a special strong affinity with Ti and a therapeutic effect on diabetic bone loss. According to the copies of minTBP-1, three proteins were prepared, namely minTBP-1-IGF-1, 2minTBP-1-IGF-1 and 3minTBP-1-IGF-1. Compared with the other modified proteins, 3minTBP-1-IGF-1 adsorbed most on the Ti surface. Additionally, this biointerface demonstrated the most uniform state and the strongest hydrophilicity. In vitro results showed that the 3minTBP-1-IGF-1 significantly increased the adhesion, proliferation, and mineralization activity of osteoblasts under T2DM conditions when compared with the control group and the other modified IGF-1s groups. Real-time PCR assay results confirmed that 3minTBP-1-IGF-1 could effectively promote the expression of osteogenic genes, that is, ALP, BMP-2, OCN, OPG, and Runx2. All these data indicated that the 3minTBP-1-IGF-1 had the most efficacious effect in promoting osteoblasts osteogenesis in diabetic conditions, and may be a promising option for further clinical use.
Collapse
Affiliation(s)
| | | | | | - Min Zhang
- Correspondence: (M.Z.); (Y.-J.C.); (Q.Z.)
| | | | - Qian Zhang
- Correspondence: (M.Z.); (Y.-J.C.); (Q.Z.)
| |
Collapse
|
135
|
Leelatian L, Chunhabundit P, Charoonrut P, Asvanund P. Induction of Osseointegration by Nacre in Pigs. Molecules 2022; 27:molecules27092653. [PMID: 35566000 PMCID: PMC9105096 DOI: 10.3390/molecules27092653] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 04/12/2022] [Accepted: 04/18/2022] [Indexed: 01/04/2023] Open
Abstract
Nacre is a biomaterial that has shown osteoinductive and osteoconductive properties in vitro and in vivo. These properties make nacre a material of interest for inducing bone regeneration. However, information is very limited regarding the introduction of nacre to dental implant surgery for promoting osteogenesis. This study investigated the potential of nacre powder for peri-implant bone regeneration in a porcine model. Ninety-six dental implants were placed into the tibia of twelve male domestic pigs. The dental implants were coated with nacre powder from the giant oyster before implantation. Implantations without nacre powder were used as control groups. Euthanization took place at 2, 4 and 6 weeks after implantation, after which we measured bone-to-implant contact (BIC) and bone volume density (BVD) of the implanted bone samples using micro-computed tomography (micro-CT), and examined the histology of the surrounding bone using histological sections stained with Stevenel’s blue and Alizarin red S. The micro-CT analyses showed that the BIC of dental implantations with nacre powder were significantly higher than those without nacre powder, by 7.60%. BVD of implantations with nacre powder were significantly higher than those without nacre powder, by 12.48% to 13.66% in cortical bone, and by 3.37% to 6.11% in spongy bone. Histological study revealed more peri-implant bone regeneration toward the surface of the dental implants after implantation with nacre powder. This was consistent with the micro-CT results. This study demonstrates the feasibility of using nacre to promote peri-implant bone regeneration in dental implantation.
Collapse
Affiliation(s)
- Leena Leelatian
- Ph.D. Student, Molecular Medicine Program, Faculty of Science, Mahidol University, Bangkok 10400, Thailand;
| | - Panjit Chunhabundit
- Department of Anatomy, Faculty of Dentistry, Mahidol University, Bangkok 10400, Thailand
- Correspondence: ; Tel.: +66-0900903672
| | - Phingphol Charoonrut
- Department of Clinical Science and Public Health, Faculty of Veterinary Science, Mahidol University, Nakhon Pathom 73170, Thailand;
| | | |
Collapse
|
136
|
Hympanova M, Oliver-Urrutia C, Vojta M, Macháček M, Krupka P, Kukla R, Celko L, Montufar EB, Marek J. Assessment of Streptococcus mutans biofilm formation on calcium phosphate ceramics: The role of crystalline composition and microstructure. BIOMATERIALS ADVANCES 2022; 135:212750. [PMID: 35929222 DOI: 10.1016/j.bioadv.2022.212750] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 02/14/2022] [Accepted: 03/04/2022] [Indexed: 06/15/2023]
Abstract
Streptococcus mutans is one of the bacteria that initiates the colonization of the pellicle at the tooth surface. It forms a plaque, together with other bacteria, which gradually dissolves the pellicle and leaves the tooth surface unprotected against the acidic oral environment. Calcium phosphate ceramics are excellent synthetic materials for the study of biofilm formation in dentistry because they are comparable to teeth in chemical composition and structure. Calcium phosphates can be processed to achieve a variety of crystalline compounds with biologically relevant ionic substitutions and structures that allow study of the effect of the surface chemistry and the topography independently. In this article, we describe the preparation and characterization of three types of calcium phosphate-based materials as a suitable surface for the formation of the S. mutans biofilm: beta-tricalcium phosphate (β-TCP); sintered hydroxyapatite (SHA); and calcium-deficient hydroxyapatite (CDHA). The densest biofilms were formed on the surfaces of SHA and CDHA, with no significant differences due to the stoichiometry or microstructure. In contrast, β-TCP showed a lower susceptibility to S. mutans biofilm formation, suggesting that the crystalline structure is the controlling parameter. Subsequently, SHA was selected to develop a dental biofilm model that allowed study of S. mutans biofilm susceptibility to chlorhexidine and ethanol.
Collapse
Affiliation(s)
- Michaela Hympanova
- Biomedical Research Centre, University Hospital Hradec Kralove, Sokolska 581, 500 05 Hradec Kralove, Czech Republic; Department of Epidemiology, Faculty of Military Health Sciences, University of Defence, Trebesska 1575, 500 05 Hradec Kralove, Czech Republic
| | - Carolina Oliver-Urrutia
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, 61200 Brno, Czech Republic
| | - Marek Vojta
- Department of Biology, Faculty of Science, University of Hradec Kralove, Rokitanskeho 62, 500 03 Hradec Kralove, Czech Republic
| | - Miloslav Macháček
- Department of Biochemical Sciences, Faculty of Pharmacy in Hradec Kralove, Charles University, Heyrovskeho 1203, Hradec Kralove 500 05, Czech Republic
| | - Pavel Krupka
- Department of Dentistry, University Hospital Hradec Kralove, Sokolska 581, 500 05 Hradec Kralove, Czech Republic
| | - Rudolf Kukla
- Department of Clinical Microbiology, University Hospital Hradec Kralove, Sokolska 581, 500 05 Hradec Kralove, Czech Republic
| | - Ladislav Celko
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, 61200 Brno, Czech Republic
| | - Edgar B Montufar
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, 61200 Brno, Czech Republic.
| | - Jan Marek
- Biomedical Research Centre, University Hospital Hradec Kralove, Sokolska 581, 500 05 Hradec Kralove, Czech Republic; Department of Epidemiology, Faculty of Military Health Sciences, University of Defence, Trebesska 1575, 500 05 Hradec Kralove, Czech Republic.
| |
Collapse
|
137
|
Improvement in Osseointegration of Titanium Dental Implants after Exposure to Ultraviolet-C Light for Various Times: an Experimental Study in Beagle Dogs. J Oral Maxillofac Surg 2022; 80:1389-1397. [DOI: 10.1016/j.joms.2022.04.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 04/10/2022] [Accepted: 04/23/2022] [Indexed: 12/11/2022]
|
138
|
Dabbah K, Perelshtein I, Gedanken A, Houri-Haddad Y, Feuerstein O. Effects of a ZnCuO-Nanocoated Ti-6Al-4V Surface on Bacterial and Host Cells. MATERIALS 2022; 15:ma15072514. [PMID: 35407847 PMCID: PMC8999654 DOI: 10.3390/ma15072514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Revised: 03/25/2022] [Accepted: 03/27/2022] [Indexed: 02/01/2023]
Abstract
This study aims to investigate the effects of a novel ZnCuO nanoparticle coating for dental implants—versus those of conventional titanium surfaces—on bacteria and host cells. A multispecies biofilm composed of Streptococcus sanguinis, Actinomyces naeslundii, Porphyromonas gingivalis, and Fusobacterium nucleatum was grown for 14 days on various titanium discs: machined, sandblasted, sandblasted and acid-etched (SLA), ZnCuO-coated, and hydroxyapatite discs. Bacterial species were quantified with qPCR, and their viability was examined via confocal microscopy. Osteoblast-like and macrophage-like cells grown on the various discs for 48 h were examined for proliferation using an XTT assay, and for activity using ALP and TNF-α assays. The CSLM revealed more dead bacteria in biofilms grown on titanium than on hydroxyapatite, and less on sandblasted than on machined and ZnCuO-coated surfaces, with the latter showing a significant decrease in all four biofilm species. The osteoblast-like cells showed increased proliferation on all of the titanium surfaces, with higher activity on the ZnCuO-coated and sandblasted discs. The macrophage-like cells showed higher proliferation on the hydroxyapatite and sandblasted discs, and lower activity on the SLA and ZnCuO-coated discs. The ZnCuO-coated titanium has anti-biofilm characteristics with desired effects on host cells, thus representing a promising candidate in the complex battle against peri-implantitis.
Collapse
Affiliation(s)
- Kamal Dabbah
- Department of Prosthodontics, Hadassah Medical Center, Faculty of Dental Medicine, The Hebrew University of Jerusalem, Jerusalem 9112001, Israel; (K.D.); (Y.H.-H.)
| | - Ilana Perelshtein
- Department of Chemistry, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan 5290002, Israel; (I.P.); (A.G.)
| | - Aharon Gedanken
- Department of Chemistry, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan 5290002, Israel; (I.P.); (A.G.)
| | - Yael Houri-Haddad
- Department of Prosthodontics, Hadassah Medical Center, Faculty of Dental Medicine, The Hebrew University of Jerusalem, Jerusalem 9112001, Israel; (K.D.); (Y.H.-H.)
| | - Osnat Feuerstein
- Department of Prosthodontics, Hadassah Medical Center, Faculty of Dental Medicine, The Hebrew University of Jerusalem, Jerusalem 9112001, Israel; (K.D.); (Y.H.-H.)
- Correspondence: ; Tel.: +972-2-6778158
| |
Collapse
|
139
|
Singhal L, Belludi SA, Pradhan N, Manvi S. A comparative evaluation of the effect of platelet rich fibrin matrix with and without peripheral blood mesenchymal stem cells on dental implant stability: A randomized controlled clinical trial. J Tissue Eng Regen Med 2022; 16:422-430. [PMID: 35172029 DOI: 10.1002/term.3290] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 02/01/2022] [Accepted: 02/02/2022] [Indexed: 01/03/2023]
Abstract
Technological advances in the field of implantology have led to the concept of surface modifications to enhance implant stability by utilization of current concepts of tissue engineering and materials such as platelet concentrates and stem cells. The purpose of the present randomized controlled clinical trial was to evaluate and compare the effect of platelet rich fibrin matrix (PRFM) with and without peripheral blood mesenchymal stem cells (PBMSCs) on implant stability; by assessing the bone to implant contact (BIC) using resonance frequency analysis (RFA), insertion torque and also to establish and correlate the same with implant stability quotient (ISQ). A total of 15 patients with 30 sites ensuring a minimum of two dental implants adjacently placed in an edentulous area; with the age group of 25-50 years of both the sexes were categorized into Group 1 (dental implant with PRFM) and Group 2 (dental implant with PBMSCs embedded in PRFM). Insertion torque values at the time of dental implant placement and ISQ using RFA was recorded at 1 week, 1 month, and 3 months post operatively. There was no significant difference (p = 0.81) in Insertion torque values between both the groups (G1 and G2). Platelet rich fibrin matrix along with PBMSCs enhanced implant stability as higher and statistically significant ISQ values were noted at 1 week (p = 0.18), 1 month (p ≤ 0.001), and 3 months (p ≤ 0.001) intervals in the G2 group. Platelet rich fibrin matrix and PBMSCs showed promising results as a potential regenerative material for increasing and enhancing BIC and hence implant stability.
Collapse
Affiliation(s)
- Laveena Singhal
- Department of Periodontics, KLE Society's Institute of Dental Sciences, Bangalore, India.,Anandam ENT Head and Neck Super Speciality Centre, Siliguri, West Bengal, India
| | - Sphoorthi Anup Belludi
- Department of Periodontics, KLE Society's Institute of Dental Sciences, Bangalore, India
| | - Neha Pradhan
- Department of Periodontics, KLE Society's Institute of Dental Sciences, Bangalore, India
| | - Supriya Manvi
- Department of Implantology, KLE Society's Institute of Dental Sciences, Bangalore, India
| |
Collapse
|
140
|
Ahmed O, Sibuyi NRS, Fadaka AO, Madiehe MA, Maboza E, Meyer M, Geerts G. Plant Extract-Synthesized Silver Nanoparticles for Application in Dental Therapy. Pharmaceutics 2022; 14:380. [PMID: 35214112 PMCID: PMC8875651 DOI: 10.3390/pharmaceutics14020380] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 01/16/2022] [Accepted: 01/29/2022] [Indexed: 12/22/2022] Open
Abstract
Oral diseases are the most common non-communicable diseases in the world, with dental caries and periodontitis causing major health and social problems. These diseases can progress to systematic diseases and cause disfigurement when left untreated. However, treatment of oral diseases is among the most expensive treatments and often focus on restoration of form and function. Caries prevention has traditionally relied on oral hygiene and diet control, among other preventive measures. In this paper, these measures are not disqualified but are brought into a new context through the use of nanotechnology-based materials to improve these conventional therapeutic and preventive measures. Among inorganic nanomaterials, silver nanoparticles (AgNPs) have shown promising outcomes in dental therapy, due to their unique physicochemical properties and enhanced anti-bacterial activities. As such, AgNPs may provide newer strategies for treatment and prevention of dental infections. However, numerous concerns around the chemical synthesis of nanomaterials, which are not limited to cost and use of toxic reducing agents, have been raised. This has inspired the green synthesis route, which uses natural products as reducing agents. The biogenic AgNPs were reported to be biocompatible and environmentally friendly when compared to the chemically-synthesized AgNPs. As such, plant-synthesized AgNPs can be used as antimicrobial, antifouling, and remineralizing agents for management and treatment of dental infections and diseases.
Collapse
Affiliation(s)
- Omnia Ahmed
- Department of Restorative Dentistry, University of the Western Cape, Bellville 7535, South Africa;
| | - Nicole Remaliah Samantha Sibuyi
- Department of Science and Innovation (DSI), Mintek Nanotechnology Innovation Centre (NIC) Biolabels Research Node, Department of Biotechnology, University of the Western Cape, Bellville 7535, South Africa; (N.R.S.S.); (A.O.F.); (M.A.M.)
| | - Adewale Oluwaseun Fadaka
- Department of Science and Innovation (DSI), Mintek Nanotechnology Innovation Centre (NIC) Biolabels Research Node, Department of Biotechnology, University of the Western Cape, Bellville 7535, South Africa; (N.R.S.S.); (A.O.F.); (M.A.M.)
| | - Madimabe Abram Madiehe
- Department of Science and Innovation (DSI), Mintek Nanotechnology Innovation Centre (NIC) Biolabels Research Node, Department of Biotechnology, University of the Western Cape, Bellville 7535, South Africa; (N.R.S.S.); (A.O.F.); (M.A.M.)
| | - Ernest Maboza
- Oral and Dental Research Laboratory, University of the Western Cape, Bellville 7535, South Africa;
| | - Mervin Meyer
- Department of Science and Innovation (DSI), Mintek Nanotechnology Innovation Centre (NIC) Biolabels Research Node, Department of Biotechnology, University of the Western Cape, Bellville 7535, South Africa; (N.R.S.S.); (A.O.F.); (M.A.M.)
| | - Greta Geerts
- Department of Restorative Dentistry, University of the Western Cape, Bellville 7535, South Africa;
| |
Collapse
|
141
|
Dentin Matrix Protein 1 on Titanium Surface Facilitates Osteogenic Differentiation of Stem Cells. Molecules 2021; 26:molecules26226756. [PMID: 34833848 PMCID: PMC8621853 DOI: 10.3390/molecules26226756] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Revised: 10/31/2021] [Accepted: 11/03/2021] [Indexed: 11/16/2022] Open
Abstract
Dentin matrix protein 1 (DMP1) contains a large number of acidic domains, multiple phosphorylation sites, a functional arginine-glycine-aspartate (RGD) motif, and a DNA binding domain, and has been shown to play essential regulatory function in dentin and bone mineralization. DMP1 could also orchestrate bone matrix formation, but the ability of DMP1 on Ti to human mesenchymal stem cell (hMSC) conversion to osteoblasts has not been studied. There is importance to test if the DMP1 coated Ti surface would promote cell migration and attachment to the metal surface and promote the differentiation of the attached stem cells to an osteogenic lineage. This study aimed to study the human mesenchymal stem cells (hMSCs) attachment and proliferation on DMP1 coated titanium (Ti) disks compared to non-coated disks, and to assess possible osteoblastic differentiation of attached hMSCs. Sixty-eight Ti disks were divided into two groups. Group 1 disks were coated with dentin matrix protein 1 and group 2 disks served as control. Assessment with light microscopy was used to verify hMSC attachment and proliferation. Cell viability was confirmed through fluorescence microscopy and mitochondrial dehydrogenase activity. Real-time polymerase chain reaction analysis was done to study the gene expression. The proliferation assay showed significantly greater cell proliferation with DMP1 coated disks compared to the control group (p-value < 0.001). Cell vitality analysis showed a greater density of live cells on DMP1 coated disks compared to the control group. Alkaline phosphatase staining revealed higher enzyme activity on DMP1 coated disks and showed itself to be significantly higher than the control group (p-value < 0.001). von Kossa staining revealed higher positive areas for mineralized deposits on DMP1 coated disks than the control group (p-value < 0.05). Gene expression analysis confirmed upregulation of runt-related transcription factor 2, osteoprotegerin, osteocalcin, osteopontin, and alkaline phosphatase on DMP1 coated disks (p-value < 0.001). The dentin matrix protein promoted the adhesion, proliferation, facilitation differentiation of hMSC, and mineralized matrix formation.
Collapse
|
142
|
Man K, Brunet MY, Louth S, Robinson TE, Fernandez-Rhodes M, Williams S, Federici AS, Davies OG, Hoey DA, Cox SC. Development of a Bone-Mimetic 3D Printed Ti6Al4V Scaffold to Enhance Osteoblast-Derived Extracellular Vesicles' Therapeutic Efficacy for Bone Regeneration. Front Bioeng Biotechnol 2021; 9:757220. [PMID: 34765595 PMCID: PMC8576375 DOI: 10.3389/fbioe.2021.757220] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Accepted: 10/08/2021] [Indexed: 12/11/2022] Open
Abstract
Extracellular Vesicles (EVs) are considered promising nanoscale therapeutics for bone regeneration. To date, EVs are typically procured from cells on 2D tissue culture plastic, an artificial environment that limits cell growth and does not replicate in situ biochemical or biophysical conditions. This study investigated the potential of 3D printed titanium scaffolds coated with hydroxyapatite to promote the therapeutic efficacy of osteoblast-derived EVs. Ti6Al4V titanium scaffolds with different pore sizes (500 and 1000 µm) and shapes (square and triangle) were fabricated by selective laser melting. A bone-mimetic nano-needle hydroxyapatite (nnHA) coating was then applied. EVs were procured from scaffold-cultured osteoblasts over 2 weeks and vesicle concentration was determined using the CD63 ELISA. Osteogenic differentiation of human bone marrow stromal cells (hBMSCs) following treatment with primed EVs was evaluated by assessing alkaline phosphatase activity, collagen production and calcium deposition. Triangle pore scaffolds significantly increased osteoblast mineralisation (1.5-fold) when compared to square architectures (P ≤ 0.001). Interestingly, EV yield was also significantly enhanced on these higher permeability structures (P ≤ 0.001), in particular (2.2-fold) for the larger pore structures (1000 µm). Furthermore osteoblast-derived EVs isolated from triangular pore scaffolds significantly increased hBMSCs mineralisation when compared to EVs acquired from square pore scaffolds (1.7-fold) and 2D culture (2.2-fold) (P ≤ 0.001). Coating with nnHA significantly improved osteoblast mineralisation (>2.6-fold) and EV production (4.5-fold) when compared to uncoated scaffolds (P ≤ 0.001). Together, these findings demonstrate the potential of harnessing bone-mimetic culture platforms to enhance the production of pro-regenerative EVs as an acellular tool for bone repair.
Collapse
Affiliation(s)
- Kenny Man
- School of Chemical Engineering, University of Birmingham, Birmingham, United Kingdom
| | - Mathieu Y. Brunet
- School of Chemical Engineering, University of Birmingham, Birmingham, United Kingdom
| | - Sophie Louth
- School of Chemical Engineering, University of Birmingham, Birmingham, United Kingdom
| | - Thomas E. Robinson
- School of Chemical Engineering, University of Birmingham, Birmingham, United Kingdom
| | - Maria Fernandez-Rhodes
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, United Kingdom
| | - Soraya Williams
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, United Kingdom
| | - Angelica S. Federici
- Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin, Ireland
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
- Advanced Materials and Bioengineering Research Centre, Trinity College Dublin and RCSI, Dublin, Ireland
| | - Owen G. Davies
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, United Kingdom
| | - David A. Hoey
- Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin, Ireland
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
- Advanced Materials and Bioengineering Research Centre, Trinity College Dublin and RCSI, Dublin, Ireland
| | - Sophie C. Cox
- School of Chemical Engineering, University of Birmingham, Birmingham, United Kingdom
| |
Collapse
|
143
|
Li Y, Chen G, He Y, Yi C, Zhang X, Zeng B, Huang Z, Deng F, Yu D. Selenomethionine-Modified Polyethylenimine-Based Nanoparticles Loaded with miR-132-3p Inhibitor-Biofunctionalized Titanium Implants for Improved Osteointegration. ACS Biomater Sci Eng 2021; 7:4933-4945. [PMID: 34583510 DOI: 10.1021/acsbiomaterials.1c00880] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Titanium and its alloys have been widely used as bone implants, but for reduced treatment span, improvements are urgently needed to achieve faster and better osteointegration. In this study, we found that miR-132-3p inhibited bone-marrow-derived stem cell (BMSC) osteogenic differentiation via targeting BMP2, and that inhibiting miR-132-3p could significantly improve the osteogenic capability of BMSCs. Moreover, we fabricated a biocompatible selenomethionine (SEMET)-modified polyethylene glycol (PEG)/polyethylenimine (PEI) nanoparticle (SeNP) cross-linked with 0.2% gelatin solutions and delivered miR-132-3p inhibitor to biofunctionalize alkali heat-treated titanium implants, resulting in the development of a novel coating for reverse transfection. The biological performances of PEG/PEI/miR-132-3p inhibitor and SeNP/miR-132-3p inhibitor-biofunctionalized titanium were compared. The biological effects, including cell viability, cytotoxicity, adhesion, cellular uptake, and osteogenic capacity of SeNP/miR-132-3p inhibitor-biofunctionalized titanium implants, were then assessed. Results showed that SeNPs presented appropriate morphology, diameter, and positive zeta potential for efficient gene delivery. The transfection efficiency of the SeNP/miR-132-3p inhibitor was comparable to that of the PEG/PEI/miR-132-3p inhibitor, but the former induced less reactive oxygen species (ROS) production and lower apoptosis rates. Confocal laser scanning microscopy (CLSM) demonstrated that SeNP/miR-132-3p inhibitor nanoparticles released from the titanium surfaces and were taken up by adherent BMSCs. In addition, the release profile showed that transfection could obtain a long-lasting silencing effect for more than 2 weeks. The cell viability, cytotoxicity, and cell spreading of SeNP/miRNA-132-3p inhibitor-biofunctionalized titanium were comparable with those of untreated titanium and the SeNP/miRNA-132-3p inhibitor negative control (NC)-biofunctionalized titanium but resulted in higher ALP activity and osteogenic gene expression levels. In vivo animal studies further certified that SeNP/miRNA-132-3p inhibitor nanoparticles from titanium surfaces promoted osteointegration, which was revealed by microcomputed tomography (micro-CT) and histological observations. Taken together, these findings suggested that selenomethionine-modified PEI-based nanoparticles could achieve better biocompatibility. Moreover, titanium implants biofunctionalized by SeNP/miRNA-132-3p inhibitor nanoparticles might have significant clinical potential for more effective osteointegration.
Collapse
Affiliation(s)
- Yiming Li
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, PR China
| | - Guanhui Chen
- Department of Stomatology, the Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, Guangdong 518107, China
| | - Yi He
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, PR China
| | - Chen Yi
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, PR China
| | - Xiliu Zhang
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, PR China
| | - Binghui Zeng
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, PR China
| | - Ziqing Huang
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, PR China
| | - Feilong Deng
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, PR China
| | - Dongsheng Yu
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, PR China
| |
Collapse
|
144
|
Abstract
This review aims to discuss the advantages and disadvantages of zirconia implants compared with titanium implants. Moreover, it intends to review the relevant available long-term literature of these two materials regarding osteointegration, soft-tissue, microbiota, and peri-implantitis, focusing on clinical results. Briefly, titanium implants are a reliable alternative for missing teeth; however, they are not incapable of failure. In an attempt to provide an alternative implant material, implants made from ceramic-derivate products were developed. Owing to its optimal osseointegration competence, biocompatibility, and esthetic proprieties, zirconium dioxide (ZrO2), also known as zirconia, has gained popularity among researchers and clinicians, being a metal-free alternative for titanium implants with its main use in the anterior esthetic zones. This type of implant may present similar osseointegration as those noted on titanium implants with a greater soft-tissue response. Furthermore, this material does not show corrosion as its titanium analog, and it is less susceptible to bacterial adhesion. Lastly, even presenting a similar inflammatory response to titanium, zirconia implants offer less biofilm formation, suggesting less susceptibility to peri-implantitis. However, it is a relatively new material that has been commercially available for a decade; consequently, the literature still lacks studies with long follow-up periods.
Collapse
|
145
|
Komatsu T, Ohta H, Motegi H, Hata J, Terawaki K, Koizumi M, Muta K, Okano HJ, Iguchi Y. A novel model of ischemia in rats with middle cerebral artery occlusion using a microcatheter and zirconia ball under fluoroscopy. Sci Rep 2021; 11:12806. [PMID: 34140618 PMCID: PMC8211726 DOI: 10.1038/s41598-021-92321-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2021] [Accepted: 06/04/2021] [Indexed: 12/21/2022] Open
Abstract
The failure of neuroprotective treatment-related clinical trials may be partially caused by unestablished animal models. Existing animal models are less likely to provide occlusion confined to the middle cerebral artery (MCA), making transarterial intervention difficult. We aimed to develop a novel focal stroke model using a microcatheter and zirconium dioxide that is non-magnetic under fluoroscopic guidance, which can monitor MCA occlusion and can improve hemorrhagic complications. Using male Sprague Dawley rats (n = 10), a microcatheter was navigated from the caudal ventral artery to the left internal carotid artery using an X-ray fluoroscopy to establish local occlusion. All rat cerebral angiographies were successful. No rats had hemorrhagic complications. Eight (80%) rats underwent occlusion of the MCA bifurcation by zirconium dioxide. Accidentally, the left posterior cerebral artery was failure embolized in 2 rats (20%). The median operating time was 8 min. All rats of occlusion MCA revealed an incomplete hemiparesis on the right side with neurological deficit score ranging from 1 to 3 (median 1, interquartile range 1-3) at 24 h after the induction of ischemia. Moreover, 2% 2,3,5-triphenyl tetrazolium chloride staining showed that the median infarct volume (mm3) was 280 (interquartile range 267-333) 24 h after the left MCA bifurcation occlusion. We present a novel rat model for focal stroke using a microcatheter and zirconium dioxide which does not affect the MRI. The model is predictable which is well confined within the territory supplied by the MCA, and reproducibility of this model is 80%. Fluoroscopy was able to identify which the MCA occlusion and model success while creating the model. It permitted exclusion of animals with complications from the experiment.
Collapse
Affiliation(s)
- Teppei Komatsu
- Department of Neurology, The Jikei University School of Medicine, 3-25-8 Nishishimbashi, Minato-ku, Tokyo, 105-8461, Japan.
| | - Hiroki Ohta
- Division of Regenerative Medicine, Research Center for Medical Sciences, The Jikei University School of Medicine, Tokyo, Japan
| | - Haruhiko Motegi
- Department of Neurology, The Jikei University School of Medicine, 3-25-8 Nishishimbashi, Minato-ku, Tokyo, 105-8461, Japan
| | - Junichi Hata
- Division of Regenerative Medicine, Research Center for Medical Sciences, The Jikei University School of Medicine, Tokyo, Japan
| | - Koshiro Terawaki
- Department of Radiological Science, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Tokyo, Japan
| | - Makoto Koizumi
- Laboratory Animal Facilities, Research Center for Medical Sciences, The Jikei University School of Medicine, Tokyo, Japan
| | - Kanako Muta
- Laboratory of Veterinary Surgery, Graduate School of Agricultural and Life Sciences, The University of Tokyo, Tokyo, Japan
| | - Hirotaka James Okano
- Division of Regenerative Medicine, Research Center for Medical Sciences, The Jikei University School of Medicine, Tokyo, Japan
| | - Yasuyuki Iguchi
- Department of Neurology, The Jikei University School of Medicine, 3-25-8 Nishishimbashi, Minato-ku, Tokyo, 105-8461, Japan
| |
Collapse
|
146
|
Electrochemical, Tribological and Biocompatible Performance of Electron Beam Modified and Coated Ti6Al4V Alloy. Int J Mol Sci 2021; 22:ijms22126369. [PMID: 34198700 PMCID: PMC8232333 DOI: 10.3390/ijms22126369] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 05/31/2021] [Accepted: 06/11/2021] [Indexed: 12/30/2022] Open
Abstract
Vacuum cathodic arc TiN coatings with overlaying TiO2 film were deposited on polished and surface roughened by electron beam modification (EBM) Ti6Al4V alloy. The substrate microtopography consisted of long grooves formed by the liner scan of the electron beam with appropriate frequencies (500 (AR500) and 850 (AR850) Hz). EBM transformed the α + β Ti6Al4V mixed structure into a single α'-martensite phase. Тhe gradient TiN/TiO2 films deposited on mechanically polished (AR) and EBM (AR500 and AR850) alloys share the same surface chemistry and composition (almost stoichiometric TiN, anatase and rutile in different ratios) but exhibit different topographies (Sa equal to approximately 0.62, 1.73, and 1.08 μm, respectively) over areas of 50 × 50 μm. Although the nanohardness of the coatings on AR500 and AR850 alloy (approximately 10.45 and 9.02 GPa, respectively) was lower than that measured on the film deposited on AR alloy (about 13.05 GPa), the hybrid surface treatment offered improvement in critical adhesive loads, coefficient of friction, and wear-resistance of the surface. In phosphate buffer saline, all coated samples showed low corrosion potentials and passivation current densities, confirming their good corrosion protection. The coated EBM samples cultured with human osteoblast-like MG63 cells demonstrated increased cell attachment, viability, and bone mineralization activity especially for the AR500-coated alloy, compared to uncoated polished alloy. The results underline the synergetic effect between the sub-micron structure and composition of TiN/TiO2 coating and microarchitecture obtained by EBM.
Collapse
|