1
|
Humbert C, Barriol M, Varsavas SD, Nicolay P, Brandstötter M. A Simple Method to Manufacture a Force Sensor Array Based on a Single-Material 3D-Printed Piezoresistive Foam and Metal Coating. SENSORS (BASEL, SWITZERLAND) 2024; 24:3854. [PMID: 38931638 PMCID: PMC11207248 DOI: 10.3390/s24123854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 06/03/2024] [Accepted: 06/06/2024] [Indexed: 06/28/2024]
Abstract
Nowadays, 3D printing is becoming an increasingly common option for the manufacturing of sensors, primarily due to its capacity to produce intricate geometric shapes. However, a significant challenge persists in integrating multiple materials during printing, for various reasons. In this study, we propose a straightforward approach that combines 3D printing with metal coating to create an array of resistive force sensors from a single material. The core concept involves printing a sensing element using a conductive material and subsequently separating it into distinct parts using metal-coated lines connected to the electrical ground. This post-printing separation process involves manual intervention utilizing a stencil and metallic spray. The primary obstacle lies in establishing a sufficient contact surface between the sprayed metal and the structure, to ensure effective isolation among different zones. To address this challenge, we suggest employing a lattice structure to augment the contact surface area. Through experimental validation, we demonstrate the feasibility of fabricating two sensing elements from a single-material 3D-printed structure, with a maximum electrical isolation ratio between the sensors of above 30. These findings hold promise for the development of a new generation of low-tech 3D-printed force/displacement sensor arrays.
Collapse
Affiliation(s)
- Claude Humbert
- CiSMAT—Carinthia Institute for Smart Materials, Carinthia University of Applied Sciences, 9524 Villach, Austria
| | - Mathis Barriol
- CiSMAT—Carinthia Institute for Smart Materials, Carinthia University of Applied Sciences, 9524 Villach, Austria
| | - Sakine Deniz Varsavas
- ADMiRE—Additive Manufacturing, Intelligent Robotics and Engineering, Carinthia University of Applied Sciences, 9524 Villach, Austria
| | - Pascal Nicolay
- CiSMAT—Carinthia Institute for Smart Materials, Carinthia University of Applied Sciences, 9524 Villach, Austria
| | - Mathias Brandstötter
- ADMiRE—Additive Manufacturing, Intelligent Robotics and Engineering, Carinthia University of Applied Sciences, 9524 Villach, Austria
| |
Collapse
|
2
|
Zinno C, Agnesi F, D'Alesio G, Dushpanova A, Brogi L, Camboni D, Bernini F, Terlizzi D, Casieri V, Gabisonia K, Alibrandi L, Grigoratos C, Magomajew J, Aquaro GD, Schmitt S, Detemple P, Oddo CM, Lionetti V, Micera S. Implementation of an epicardial implantable MEMS sensor for continuous and real-time postoperative assessment of left ventricular activity in adult minipigs over a short- and long-term period. APL Bioeng 2024; 8:026102. [PMID: 38633836 PMCID: PMC11023704 DOI: 10.1063/5.0169207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 04/01/2024] [Indexed: 04/19/2024] Open
Abstract
The sensing of left ventricular (LV) activity is fundamental in the diagnosis and monitoring of cardiovascular health in high-risk patients after cardiac surgery to achieve better short- and long-term outcome. Conventional approaches rely on noninvasive measurements even if, in the latest years, invasive microelectromechanical systems (MEMS) sensors have emerged as a valuable approach for precise and continuous monitoring of cardiac activity. The main challenges in designing cardiac MEMS sensors are represented by miniaturization, biocompatibility, and long-term stability. Here, we present a MEMS piezoresistive cardiac sensor capable of continuous monitoring of LV activity over time following epicardial implantation with a pericardial patch graft in adult minipigs. In acute and chronic scenarios, the sensor was able to compute heart rate with a root mean square error lower than 2 BPM. Early after up to 1 month of implantation, the device was able to record the heart activity during the most important phases of the cardiac cycle (systole and diastole peaks). The sensor signal waveform, in addition, closely reflected the typical waveforms of pressure signal obtained via intraventricular catheters, offering a safer alternative to heart catheterization. Furthermore, histological analysis of the LV implantation site following sensor retrieval revealed no evidence of myocardial fibrosis. Our results suggest that the epicardial LV implantation of an MEMS sensor is a suitable and reliable approach for direct continuous monitoring of cardiac activity. This work envisions the use of this sensor as a cardiac sensing device in closed-loop applications for patients undergoing heart surgery.
Collapse
Affiliation(s)
- C. Zinno
- The BioRobotics Institute, Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - F. Agnesi
- The BioRobotics Institute, Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - G. D'Alesio
- The BioRobotics Institute, Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | | | - L. Brogi
- Bio@SNS, Scuola Normale Superiore, Pisa, Italy
| | - D. Camboni
- The BioRobotics Institute, Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - F. Bernini
- BioMedLab, Interdisciplinary Research Center “Health Science,” Scuola Superiore Sant'Anna, Pisa, Italy
| | - D. Terlizzi
- Fondazione Toscana “G. Monasterio,” Pisa, Italy
| | - V. Casieri
- Unit of Translational Critical Care Medicine, Laboratory of Basic and Applied Medical Sciences, Interdisciplinary Research Center “Health Science,” Scuola Superiore Sant'Anna, Pisa, Italy
| | - K. Gabisonia
- BioMedLab, Interdisciplinary Research Center “Health Science,” Scuola Superiore Sant'Anna, Pisa, Italy
| | - L. Alibrandi
- Unit of Translational Critical Care Medicine, Laboratory of Basic and Applied Medical Sciences, Interdisciplinary Research Center “Health Science,” Scuola Superiore Sant'Anna, Pisa, Italy
| | | | - J. Magomajew
- Department of Chemistry, Fraunhofer Institute for Microengineering and Microsystems, 55129 Mainz, Germany
| | | | - S. Schmitt
- Department of Chemistry, Fraunhofer Institute for Microengineering and Microsystems, 55129 Mainz, Germany
| | - P. Detemple
- Department of Chemistry, Fraunhofer Institute for Microengineering and Microsystems, 55129 Mainz, Germany
| | - C. M. Oddo
- The BioRobotics Institute, Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | | | - S. Micera
- Author to whom correspondence should be addressed:
| |
Collapse
|
3
|
Lee M, Lee Y, Choi JH, Kim H, Jeong D, Park K, Kim J, Park J, Jang WY, Seo J, Lee J. Postoperative Long-Term Monitoring of Mechanical Characteristics in Reconstructed Soft Tissues Using Biocompatible, Immune-Tolerant, and Wireless Electronic Sutures. ACS NANO 2024; 18:12210-12224. [PMID: 38695533 DOI: 10.1021/acsnano.4c00396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2024]
Abstract
Accurate postoperative assessment of varying mechanical properties is crucial for customizing patient-specific treatments and optimizing rehabilitation strategies following Achilles tendon (AT) rupture and reconstruction surgery. This study introduces a wireless, chip-less, and immune-tolerant in vivo strain-sensing suture designed to continuously monitor mechanical stiffness variations in the reconstructed AT throughout the healing process. This innovative sensing suture integrates a standard medical suturing thread with a wireless fiber strain-sensing system, which incorporates a fiber strain sensor and a double-layered inductive coil for wireless readout. The winding design of Au nanoparticle-based fiber electrodes and a hollow core contribute to the fiber strain sensor's high sensitivity (factor of 6.2 and 15.1 pF for revised sensitivity), negligible hysteresis, and durability over 10,000 stretching cycles. To ensure biocompatibility and immune tolerance during extended in vivo periods, an antibiofouling lubricant layer was applied to the sensing suture. Using this sensing system, we successfully monitored the strain responses of the reconstructed AT in an in vivo porcine model. This facilitated the postoperative assessment of mechanical stiffness variations through a well-established analytical model during the healing period.
Collapse
Affiliation(s)
- Mugeun Lee
- Department of Robotics and Mechatronics Engineering, DGIST Daegu 42988, Republic of Korea
| | - Yeontaek Lee
- School of Electrical and Electronic Engineering, Yonsei University Seoul 03722, Republic of Korea
| | - Ji Hye Choi
- Department of Orthopedic Surgery, Korea University College of Medicine Seoul 02841, Republic of Korea
- Institute of Nanobiomarker-Based Medicine, Korea University, Seoul 02841, Republic of Korea
| | - Hwajoong Kim
- Department of Robotics and Mechatronics Engineering, DGIST Daegu 42988, Republic of Korea
| | - Daun Jeong
- Department of Orthopedic Surgery, Korea University College of Medicine Seoul 02841, Republic of Korea
- Institute of Nanobiomarker-Based Medicine, Korea University, Seoul 02841, Republic of Korea
| | - Kijun Park
- School of Electrical and Electronic Engineering, Yonsei University Seoul 03722, Republic of Korea
| | - Jinho Kim
- Department of Robotics and Mechatronics Engineering, DGIST Daegu 42988, Republic of Korea
| | - Jae Park
- School of Electrical and Electronic Engineering, Yonsei University Seoul 03722, Republic of Korea
| | - Woo Young Jang
- Department of Orthopedic Surgery, Korea University College of Medicine Seoul 02841, Republic of Korea
- Institute of Nanobiomarker-Based Medicine, Korea University, Seoul 02841, Republic of Korea
| | - Jungmok Seo
- School of Electrical and Electronic Engineering, Yonsei University Seoul 03722, Republic of Korea
| | - Jaehong Lee
- Department of Robotics and Mechatronics Engineering, DGIST Daegu 42988, Republic of Korea
| |
Collapse
|
4
|
Papani R, Li Y, Wang S. Soft mechanical sensors for wearable and implantable applications. WILEY INTERDISCIPLINARY REVIEWS. NANOMEDICINE AND NANOBIOTECHNOLOGY 2024; 16:e1961. [PMID: 38723798 PMCID: PMC11108230 DOI: 10.1002/wnan.1961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 04/04/2024] [Accepted: 04/07/2024] [Indexed: 05/23/2024]
Abstract
Wearable and implantable sensing of biomechanical signals such as pressure, strain, shear, and vibration can enable a multitude of human-integrated applications, including on-skin monitoring of vital signs, motion tracking, monitoring of internal organ condition, restoration of lost/impaired mechanoreception, among many others. The mechanical conformability of such sensors to the human skin and tissue is critical to enhancing their biocompatibility and sensing accuracy. As such, in the recent decade, significant efforts have been made in the development of soft mechanical sensors. To satisfy the requirements of different wearable and implantable applications, such sensors have been imparted with various additional properties to make them better suited for the varied contexts of human-integrated applications. In this review, focusing on the four major types of soft mechanical sensors for pressure, strain, shear, and vibration, we discussed the recent material and device design innovations for achieving several important properties, including flexibility and stretchability, bioresorbability and biodegradability, self-healing properties, breathability, transparency, wireless communication capabilities, and high-density integration. We then went on to discuss the current research state of the use of such novel soft mechanical sensors in wearable and implantable applications, based on which future research needs were further discussed. This article is categorized under: Diagnostic Tools > Biosensing Diagnostic Tools > Diagnostic Nanodevices Implantable Materials and Surgical Technologies > Nanomaterials and Implants.
Collapse
Affiliation(s)
- Rithvik Papani
- Pritzker School of Molecular Engineering, The University of Chicago, Chicago, Illinois, USA
| | - Yang Li
- Pritzker School of Molecular Engineering, The University of Chicago, Chicago, Illinois, USA
| | - Sihong Wang
- Pritzker School of Molecular Engineering, The University of Chicago, Chicago, Illinois, USA
- Nanoscience and Technology Division and Center for Molecular Engineering, Argonne National Laboratory, Lemont, Illinois, United States
| |
Collapse
|
5
|
Zhang T, Liu N, Xu J, Liu Z, Zhou Y, Yang Y, Li S, Huang Y, Jiang S. Flexible electronics for cardiovascular healthcare monitoring. Innovation (N Y) 2023; 4:100485. [PMID: 37609559 PMCID: PMC10440597 DOI: 10.1016/j.xinn.2023.100485] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2023] [Accepted: 07/23/2023] [Indexed: 08/24/2023] Open
Abstract
Cardiovascular diseases (CVDs) are one of the most urgent threats to humans worldwide, which are responsible for almost one-third of global mortality. Over the last decade, research on flexible electronics for monitoring and treatment of CVDs has attracted tremendous attention. In contrast to conventional medical instruments in hospitals that are usually bulky, hard to move, monofunctional, and time-consuming, flexible electronics are capable of continuous, noninvasive, real-time, and portable monitoring. Notable progress has been made in this emerging field, and thus a number of significant achievements and concomitant research prospects deserve attention for practical implementation. Here, we comprehensively review the latest progress of flexible electronics for CVDs, focusing on new functions provided by flexible electronics. First, the characteristics of CVDs and flexible electronics and the foundation of their combination are briefly reviewed. Then, four representative applications of flexible electronics for CVDs are elaborated: blood pressure (BP) monitoring, electrocardiogram (ECG) monitoring, echocardiogram monitoring, and direct epicardium monitoring. Their operational principles, progress, merits and demerits, and future efforts are discussed. Finally, the remaining challenges and opportunities for flexible electronics for cardiovascular healthcare are outlined.
Collapse
Affiliation(s)
- Tianqi Zhang
- Hangzhou Institute of Technology, Xidian University, Hangzhou 311200, China
| | - Ning Liu
- Department of Gastrointestinal Surgery, Hainan General Hospital, Hainan Affiliated Hospital of Hainan Medical University, Haikou 570311, China
| | - Jing Xu
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Zeye Liu
- Department of Structural Heart Disease, National Center for Cardiovascular Disease, China & Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100037, China
| | - Yunlei Zhou
- Hangzhou Institute of Technology, Xidian University, Hangzhou 311200, China
| | - Yicheng Yang
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Shoujun Li
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Pediatric Cardiac Surgery Center, Fuwai Hospital, Chinese Academy of Medical Sciences, and Peking Union Medical College, Beijing 100037, China
| | - Yuan Huang
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Pediatric Cardiac Surgery Center, Fuwai Hospital, Chinese Academy of Medical Sciences, and Peking Union Medical College, Beijing 100037, China
| | - Shan Jiang
- Hangzhou Institute of Technology, Xidian University, Hangzhou 311200, China
| |
Collapse
|
6
|
Jen N, Hadfield J, Bessa GM, Amabili M, Nobes DS, Chung HJ. Jacketed elastomeric tubes for passive self-regulation of pulsatile flow. J Mech Behav Biomed Mater 2023; 145:105994. [PMID: 37418970 DOI: 10.1016/j.jmbbm.2023.105994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 06/22/2023] [Accepted: 06/24/2023] [Indexed: 07/09/2023]
Abstract
Regulating pulsatile flow is important to achieve optimal separation and mixing and enhanced heat transfer in microfluidic devices, as well as maintaining homeostasis in biological systems. The human aorta, a composite and layered tube made (among others) of elastin and collagen, is an inspiration for researchers who seek an engineering solution for a self-regulation of pulsatile flow. Here, we present a bio-inspired approach showing that fabric-jacketed elastomeric tubes, manufactured using commercially available silicone rubber and knitted textiles, can be used to regulate pulsatile flow. Our tubes are evaluated via incorporation into a mock-circulatory 'flow loop' that replicates the pulsatile fluid flow conditions of an ex-vivo heart perfusion (EVHP) device, a machine used in heart transplants. Pressure waveforms measured near the elastomeric tubing clearly indicated an effective flow regulation. The 'dynamic stiffening' behavior of the tubes during deformation is analyzed quantitatively. Broadly, the fabric jackets allow for the tubes to experience greater magnitudes of pressure and distension without risk of asymmetric aneurysm within the expected operating time of an EVHP. Owing to its highly tunable nature, our design may serve as a basis for tubing systems that require passive self-regulation of pulsatile flow.
Collapse
Affiliation(s)
- Nathan Jen
- Department of Chemical and Materials Engineering, University of Alberta, Edmonton, AB, Canada
| | - Jake Hadfield
- Department of Mechanical Engineering, University of Alberta, Edmonton, AB, Canada
| | - Guilherme M Bessa
- Department of Mechanical Engineering, University of Alberta, Edmonton, AB, Canada
| | - Marco Amabili
- Department of Mechanical Engineering, McGill University, Montreal, QC, Canada
| | - David S Nobes
- Department of Mechanical Engineering, University of Alberta, Edmonton, AB, Canada.
| | - Hyun-Joong Chung
- Department of Chemical and Materials Engineering, University of Alberta, Edmonton, AB, Canada.
| |
Collapse
|
7
|
Magkoutas K, Weisskopf M, Falk V, Emmert MY, Meboldt M, Cesarovic N, Schmid Daners M. Continuous Monitoring of Blood Pressure and Vascular Hemodynamic Properties With Miniature Extravascular Hall-Based Magnetic Sensor. JACC Basic Transl Sci 2023; 8:546-564. [PMID: 37325404 PMCID: PMC10264706 DOI: 10.1016/j.jacbts.2022.12.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 12/29/2022] [Accepted: 12/29/2022] [Indexed: 06/17/2023]
Abstract
Continuous measurement of vascular and hemodynamic parameters could improve monitoring of disease progression and enable timely clinical decision making and therapy surveillance in patients suffering from cardiovascular diseases. However, no reliable extravascular implantable sensor technology is currently available. Here, we report the design, characterization, and validation of an extravascular, magnetic flux sensing device capable of capturing the waveforms of the arterial wall diameter, arterial circumferential strain, and arterial pressure without restricting the arterial wall. The implantable sensing device, comprising a magnet and a magnetic flux sensing assembly, both encapsulated in biocompatible structures, has shown to be robust, with temperature and cyclic-loading stability. Continuous and accurate monitoring of arterial blood pressure and vascular properties was demonstrated with the proposed sensor in vitro with a silicone artery model and validated in vivo in a porcine model mimicking physiologic and pathologic hemodynamic conditions. The captured waveforms were further used to deduce the respiration frequency, the duration of the cardiac systolic phase, and the pulse wave velocity. The findings of this study not only suggest that the proposed sensing technology is a promising platform for accurate monitoring of arterial blood pressure and vascular properties, but also highlight the necessary changes in the technology and the implantation procedure to allow the translation of the sensing device in the clinical setting.
Collapse
Affiliation(s)
- Konstantinos Magkoutas
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Miriam Weisskopf
- Center for Surgical Research, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Volkmar Falk
- Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
- Translational Cardiovascular Technologies, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Maximilian Y. Emmert
- Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
- Institute for Regenerative Medicine, University of Zurich, Zurich, Switzerland
| | - Mirko Meboldt
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Nikola Cesarovic
- Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany
- Translational Cardiovascular Technologies, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Marianne Schmid Daners
- Institute for Dynamic Systems and Control, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| |
Collapse
|
8
|
Kight A, Pirozzi I, Liang X, McElhinney DB, Han AK, Dual SA, Cutkosky M. Decoupling Transmission and Transduction for Improved Durability of Highly Stretchable, Soft Strain Sensing: Applications in Human Health Monitoring. SENSORS (BASEL, SWITZERLAND) 2023; 23:1955. [PMID: 36850551 PMCID: PMC9967534 DOI: 10.3390/s23041955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 01/24/2023] [Accepted: 02/02/2023] [Indexed: 06/18/2023]
Abstract
This work presents a modular approach to the development of strain sensors for large deformations. The proposed method separates the extension and signal transduction mechanisms using a soft, elastomeric transmission and a high-sensitivity microelectromechanical system (MEMS) transducer. By separating the transmission and transduction, they can be optimized independently for application-specific mechanical and electrical performance. This work investigates the potential of this approach for human health monitoring as an implantable cardiac strain sensor for measuring global longitudinal strain (GLS). The durability of the sensor was evaluated by conducting cyclic loading tests over one million cycles, and the results showed negligible drift. To account for hysteresis and frequency-dependent effects, a lumped-parameter model was developed to represent the viscoelastic behavior of the sensor. Multiple model orders were considered and compared using validation and test data sets that mimic physiologically relevant dynamics. Results support the choice of a second-order model, which reduces error by 73% compared to a linear calibration. In addition, we evaluated the suitability of this sensor for the proposed application by demonstrating its ability to operate on compliant, curved surfaces. The effects of friction and boundary conditions are also empirically assessed and discussed.
Collapse
Affiliation(s)
- Ali Kight
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
| | - Ileana Pirozzi
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
| | - Xinyi Liang
- Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Doff B. McElhinney
- Department of Cardiology, Lucile Packard Children’s Hospital, Stanford University, Stanford, CA 94305, USA
| | - Amy Kyungwon Han
- Department of Mechanical Engineering, Seoul National University, Seoul 08826, Republic of Korea
| | - Seraina A. Dual
- Department of Biomedical Engineering, KTH Royal Institute of Technology, 11428 Stockholm, Sweden
| | - Mark Cutkosky
- Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA
| |
Collapse
|
9
|
Chen C, Feng J, Li J, Guo Y, Shi X, Peng H. Functional Fiber Materials to Smart Fiber Devices. Chem Rev 2023; 123:613-662. [PMID: 35977344 DOI: 10.1021/acs.chemrev.2c00192] [Citation(s) in RCA: 22] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The development of fiber materials has accompanied the evolution of human civilization for centuries. Recent advances in materials science and chemistry offered fibers new applications with various functions, including energy harvesting, energy storing, displaying, health monitoring and treating, and computing. The unique one-dimensional shape of fiber devices endows them advantages to work as human-interfaced electronics due to the small size, lightweight, flexibility, and feasibility for integration into large-scale textile systems. In this review, we first present a discussion of the basics of fiber materials and the design principles of fiber devices, followed by a comprehensive analysis on recently developed fiber devices. Finally, we provide the current challenges facing this field and give an outlook on future research directions. With novel fiber devices and new applications continuing to be discovered after two decades of research, we envision that new fiber devices could have an important impact on our life in the near future.
Collapse
Affiliation(s)
- Chuanrui Chen
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai 200438, P. R. China
| | - Jianyou Feng
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai 200438, P. R. China
| | - Jiaxin Li
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai 200438, P. R. China
| | - Yue Guo
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai 200438, P. R. China
| | - Xiang Shi
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai 200438, P. R. China
| | - Huisheng Peng
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai 200438, P. R. China
| |
Collapse
|
10
|
Ru M, Hai AM, Wang L, Yan S, Zhang Q. Recent progress in silk-based biosensors. Int J Biol Macromol 2022; 224:422-436. [DOI: 10.1016/j.ijbiomac.2022.10.134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Revised: 10/05/2022] [Accepted: 10/15/2022] [Indexed: 11/05/2022]
|
11
|
Sang M, Kim K, Shin J, Yu KJ. Ultra-Thin Flexible Encapsulating Materials for Soft Bio-Integrated Electronics. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2202980. [PMID: 36031395 PMCID: PMC9596833 DOI: 10.1002/advs.202202980] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 07/22/2022] [Indexed: 05/11/2023]
Abstract
Recently, bioelectronic devices extensively researched and developed through the convergence of flexible biocompatible materials and electronics design that enables more precise diagnostics and therapeutics in human health care and opens up the potential to expand into various fields, such as clinical medicine and biomedical research. To establish an accurate and stable bidirectional bio-interface, protection against the external environment and high mechanical deformation is essential for wearable bioelectronic devices. In the case of implantable bioelectronics, special encapsulation materials and optimized mechanical designs and configurations that provide electronic stability and functionality are required for accommodating various organ properties, lifespans, and functions in the biofluid environment. Here, this study introduces recent developments of ultra-thin encapsulations with novel materials that can preserve or even improve the electrical performance of wearable and implantable bio-integrated electronics by supporting safety and stability for protection from destruction and contamination as well as optimizing the use of bioelectronic systems in physiological environments. In addition, a summary of the materials, methods, and characteristics of the most widely used encapsulation technologies is introduced, thereby providing a strategic selection of appropriate choices of recently developed flexible bioelectronics.
Collapse
Affiliation(s)
- Mingyu Sang
- School of Electrical and Electronic EngineeringYonsei University50 Yonsei‐ro, SeodaemunguSeoul03722Republic of Korea
| | - Kyubeen Kim
- School of Electrical and Electronic EngineeringYonsei University50 Yonsei‐ro, SeodaemunguSeoul03722Republic of Korea
| | - Jongwoon Shin
- School of Electrical and Electronic EngineeringYonsei University50 Yonsei‐ro, SeodaemunguSeoul03722Republic of Korea
| | - Ki Jun Yu
- School of Electrical and Electronic EngineeringYonsei University50 Yonsei‐ro, SeodaemunguSeoul03722Republic of Korea
- YU‐KIST InstituteYonsei University50 Yonsei‐ro, SeodaemunguSeoul03722Republic of Korea
| |
Collapse
|
12
|
Tang X, Zhu Y, Guan W, Zhou W, Wei P. Advances in nanosensors for cardiovascular disease detection. Life Sci 2022; 305:120733. [DOI: 10.1016/j.lfs.2022.120733] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2022] [Revised: 06/10/2022] [Accepted: 06/21/2022] [Indexed: 12/25/2022]
|
13
|
Balakrishnan G, Song J, Mou C, Bettinger CJ. Recent Progress in Materials Chemistry to Advance Flexible Bioelectronics in Medicine. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2106787. [PMID: 34751987 PMCID: PMC8917047 DOI: 10.1002/adma.202106787] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Revised: 10/15/2021] [Indexed: 05/09/2023]
Abstract
Designing bioelectronic devices that seamlessly integrate with the human body is a technological pursuit of great importance. Bioelectronic medical devices that reliably and chronically interface with the body can advance neuroscience, health monitoring, diagnostics, and therapeutics. Recent major efforts focus on investigating strategies to fabricate flexible, stretchable, and soft electronic devices, and advances in materials chemistry have emerged as fundamental to the creation of the next generation of bioelectronics. This review summarizes contemporary advances and forthcoming technical challenges related to three principal components of bioelectronic devices: i) substrates and structural materials, ii) barrier and encapsulation materials, and iii) conductive materials. Through notable illustrations from the literature, integration and device fabrication strategies and associated challenges for each material class are highlighted.
Collapse
Affiliation(s)
| | - Jiwoo Song
- Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA
| | - Chenchen Mou
- Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA
| | | |
Collapse
|
14
|
Llerena Zambrano B, Forró C, Poloni E, Hennig R, Sivananthaguru P, Renz AF, Studart AR, Vörös J. Magnetic Manipulation of Nanowires for Engineered Stretchable Electronics. ACS NANO 2022; 16:837-846. [PMID: 34918916 DOI: 10.1021/acsnano.1c08381] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Nanowires are often key ingredients of high-tech composite materials. The properties and performance of devices created using these, depend heavily on the structure and density of the embedded nanowires. Despite significant efforts, a process that can be adapted to different materials, compatible with current nanowire deposition methods, and that is able to control both variables simultaneously has not been achieved yet. In this work, we show that we can use low magnetic fields (80 mT) to manipulate nanowires by electrostatically coating them with superparamagnetic iron oxide nanoparticles in an aqueous solution. Monolayers, multilayers, and hierarchical structures of oriented nanowires were achieved in a highly ordered manner using vacuum filtration for two types of nanowires: silver and gold-coated titanium dioxide nanowires. The produced films were embedded in an elastomer, and the strain-dependent electrical properties of the resulting composites were investigated. The orientation of the assembly with respect to the tensile strain heavily impacts the performance of the composites. Composites containing nanowires perpendicular to the strain direction exhibit an extremely low gauge factor. On the other hand, when nanowires are arranged parallel to the strain direction, the composites have a high gauge factor. The possibility to orient nanowires during the processing steps is not only interesting for the shown strain sensing application but also expected to be useful in many other areas of material science.
Collapse
Affiliation(s)
- Byron Llerena Zambrano
- Laboratory of Biosensors and Bioelectronics, ETH Zurich, Gloriastrasse 35, 8092 Zurich, Switzerland
| | - Csaba Forró
- Tissue Electronics, Istituto Italiano di Tecnologia, 80125 Naples, Italy
- Department of Chemistry, Stanford University, Stanford, California 94305-4401, United States
| | - Erik Poloni
- Complex Materials, Department of Materials, ETH Zürich, 8093 Zürich, Switzerland
| | - Robert Hennig
- Laboratory of Biosensors and Bioelectronics, ETH Zurich, Gloriastrasse 35, 8092 Zurich, Switzerland
| | - Pragash Sivananthaguru
- Laboratory of Biosensors and Bioelectronics, ETH Zurich, Gloriastrasse 35, 8092 Zurich, Switzerland
| | - Aline F Renz
- Laboratory of Biosensors and Bioelectronics, ETH Zurich, Gloriastrasse 35, 8092 Zurich, Switzerland
| | - André R Studart
- Complex Materials, Department of Materials, ETH Zürich, 8093 Zürich, Switzerland
| | - János Vörös
- Laboratory of Biosensors and Bioelectronics, ETH Zurich, Gloriastrasse 35, 8092 Zurich, Switzerland
| |
Collapse
|
15
|
Herbert R, Lim H, Park S, Kim J, Yeo W. Recent Advances in Printing Technologies of Nanomaterials for Implantable Wireless Systems in Health Monitoring and Diagnosis. Adv Healthc Mater 2021; 10:e2100158. [PMID: 34019731 DOI: 10.1002/adhm.202100158] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Revised: 05/03/2021] [Indexed: 12/17/2022]
Abstract
The development of wireless implantable sensors and integrated systems, enabled by advances in flexible and stretchable electronics technologies, is emerging to advance human health monitoring, diagnosis, and treatment. Progress in material and fabrication strategies allows for implantable electronics for unobtrusive monitoring via seamlessly interfacing with tissues and wirelessly communicating. Combining new nanomaterials and customizable printing processes offers unique possibilities for high-performance implantable electronics. Here, this report summarizes the recent progress and advances in nanomaterials and printing technologies to develop wireless implantable sensors and electronics. Advances in materials and printing processes are reviewed with a focus on challenges in implantable applications. Demonstrations of wireless implantable electronics and advantages based on these technologies are discussed. Lastly, existing challenges and future directions of nanomaterials and printing are described.
Collapse
Affiliation(s)
- Robert Herbert
- George W. Woodruff School of Mechanical Engineering Center for Human‐Centric Interfaces and Engineering Georgia Institute of Technology Atlanta GA 30332 USA
| | - Hyo‐Ryoung Lim
- George W. Woodruff School of Mechanical Engineering Center for Human‐Centric Interfaces and Engineering Georgia Institute of Technology Atlanta GA 30332 USA
| | - Sehyun Park
- School of Engineering and Computer Science Washington State University Vancouver WA 98686 USA
| | - Jong‐Hoon Kim
- School of Engineering and Computer Science Washington State University Vancouver WA 98686 USA
| | - Woon‐Hong Yeo
- George W. Woodruff School of Mechanical Engineering Center for Human‐Centric Interfaces and Engineering Georgia Institute of Technology Atlanta GA 30332 USA
- Wallace H. Coulter Department of Biomedical Engineering Parker H. Petit Institute for Bioengineering and Biosciences Neural Engineering Center Institute for Materials Institute for Robotics and Intelligent Machines Georgia Institute of Technology Atlanta GA 30332 USA
| |
Collapse
|
16
|
Han F, Li M, Ye H, Zhang G. Materials, Electrical Performance, Mechanisms, Applications, and Manufacturing Approaches for Flexible Strain Sensors. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:1220. [PMID: 34063165 PMCID: PMC8148098 DOI: 10.3390/nano11051220] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 04/30/2021] [Accepted: 05/01/2021] [Indexed: 12/13/2022]
Abstract
With the recent great progress made in flexible and wearable electronic materials, the upcoming next generation of skin-mountable and implantable smart devices holds extensive potential applications for the lifestyle modifying, including personalized health monitoring, human-machine interfaces, soft robots, and implantable biomedical devices. As a core member within the wearable electronics family, flexible strain sensors play an essential role in the structure design and functional optimization. To further enhance the stretchability, flexibility, sensitivity, and electricity performances of the flexible strain sensors, enormous efforts have been done covering the materials design, manufacturing approaches and various applications. Thus, this review summarizes the latest advances in flexible strain sensors over recent years from the material, application, and manufacturing strategies. Firstly, the critical parameters measuring the performances of flexible strain sensors and materials development contains different flexible substrates, new nano- and hybrid- materials are introduced. Then, the developed working mechanisms, theoretical analysis, and computational simulation are presented. Next, based on different material design, diverse applications including human motion detection and health monitoring, soft robotics and human-machine interface, implantable devices, and biomedical applications are highlighted. Finally, synthesis consideration of the massive production industry of flexible strain sensors in the future; different fabrication approaches that are fully expected are classified and discussed.
Collapse
Affiliation(s)
- Fei Han
- Institute of Future Lighting, Academy for Engineering and Technology, Fudan University, Shanghai 200433, China; (F.H.); (M.L.)
- Shenzhen Institute of Wide-Bandgap Semiconductors, Shenzhen 518055, China
| | - Min Li
- Institute of Future Lighting, Academy for Engineering and Technology, Fudan University, Shanghai 200433, China; (F.H.); (M.L.)
| | - Huaiyu Ye
- Shenzhen Institute of Wide-Bandgap Semiconductors, Shenzhen 518055, China
| | - Guoqi Zhang
- Institute of Future Lighting, Academy for Engineering and Technology, Fudan University, Shanghai 200433, China; (F.H.); (M.L.)
- Shenzhen Institute of Wide-Bandgap Semiconductors, Shenzhen 518055, China
| |
Collapse
|
17
|
Llerena Zambrano B, Renz AF, Ruff T, Lienemann S, Tybrandt K, Vörös J, Lee J. Soft Electronics Based on Stretchable and Conductive Nanocomposites for Biomedical Applications. Adv Healthc Mater 2021; 10:e2001397. [PMID: 33205564 DOI: 10.1002/adhm.202001397] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2020] [Revised: 10/08/2020] [Indexed: 12/15/2022]
Abstract
Research on the field of implantable electronic devices that can be directly applied in the body with various functionalities is increasingly intensifying due to its great potential for various therapeutic applications. While conventional implantable electronics generally include rigid and hard conductive materials, their surrounding biological objects are soft and dynamic. The mechanical mismatch between implanted devices and biological environments induces damages in the body especially for long-term applications. Stretchable electronics with outstanding mechanical compliance with biological objects effectively improve such limitations of existing rigid implantable electronics. In this article, the recent progress of implantable soft electronics based on various conductive nanocomposites is systematically described. In particular, representative fabrication approaches of conductive and stretchable nanocomposites for implantable soft electronics and various in vivo applications of implantable soft electronics are focused on. To conclude, challenges and perspectives of current implantable soft electronics that should be considered for further advances are discussed.
Collapse
Affiliation(s)
- Byron Llerena Zambrano
- Laboratory of Biosensors and Bioelectronics ETH Zurich Gloriastrasse 35 Zurich 8092 Switzerland
| | - Aline F. Renz
- Laboratory of Biosensors and Bioelectronics ETH Zurich Gloriastrasse 35 Zurich 8092 Switzerland
| | - Tobias Ruff
- Laboratory of Biosensors and Bioelectronics ETH Zurich Gloriastrasse 35 Zurich 8092 Switzerland
| | - Samuel Lienemann
- Laboratory of Organic Electronics Department of Science and Technology Linköping University Norrköping 601 74 Sweden
| | - Klas Tybrandt
- Laboratory of Organic Electronics Department of Science and Technology Linköping University Norrköping 601 74 Sweden
| | - János Vörös
- Laboratory of Biosensors and Bioelectronics ETH Zurich Gloriastrasse 35 Zurich 8092 Switzerland
| | - Jaehong Lee
- Department of Robotics Engineering Daegu Gyeongbuk Institute of Science and Technology (DGIST) 333 Techno jungan‐dareo Daegu 42988 South Korea
| |
Collapse
|