Caliskan-Aydogan O, Zaborney Kline C, Alocilja EC. Carbapenem-Resistant E. coli Adherence to Magnetic Nanoparticles. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:2010. [PMID: 39728546 DOI: 10.3390/nano14242010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2024] [Revised: 12/07/2024] [Accepted: 12/10/2024] [Indexed: 12/28/2024]
Abstract
Carbapenem-resistant Enterobacterales (CRE) is an emerging global concern. Specifically, carbapenemase-producing (CP) E. coli strains in CRE have recently been found in clinical, environmental, and food samples worldwide, causing many hospitalizations and deaths. Their rapid identification and characterization are paramount in control, management options, and treatment choices. Thus, this study aimed to characterize the cell surface properties of carbapenem-resistant (R) E. coli isolates and their interaction with glycan-coated magnetic nanoparticles (gMNPs) compared with carbapenem-susceptible (S) E coli. This study used two groups of bacteria: The first group included E. coli (R) isolates harboring carbapenemases and had no antibiotic exposure. Their initial gMNP-cell binding capacity, with cell surface characteristics, was assessed. In the second group, one of the E. coli (R) isolates and E. coli (S) had long-term serial antibiotic exposure, which we used to observe their cell surface characteristics and gMNP interactions. Initially, cell surface characteristics (cell morphology and cell surface charge) of the E. coli isolates were evaluated using confocal laser scanning microscope (LSCM) and a Zetasizer, respectively. The interaction of gMNPs with the E. coli isolates was assessed through LSCM and transmission electron microscope (TEM). Further, the gMNP-cell attachment was quantified as a concentration factor (CF) through the standard plating method. The results showed that the CF values of all E. coli (R) were significantly different from those of E. coli (S), which could be due to the differences in cell characteristics. The E. coli (R) isolates displayed heterogeneous cell shapes (rod and round cells) and lower negative zeta potential (cell surface charge) values compared to E. coli (S). Further, this research identified the differences in the cell surface characteristics of E. coli (S) under carbapenem exposure, compared to unexposed E. coli (S) that impact their attachment capacity. The gMNPs captured more E. coli (S) cells compared to carbapenem-exposed E. coli (S) and all E. coli (R) isolates. This study clearly found that differences in cell surface characteristics impact their interaction with magnetic nanoparticles. The gained insights aid in further understanding adhesion mechanisms to develop or improve bacterial isolation techniques and diagnostic and treatment methods for CRE.
Collapse
Affiliation(s)
- Oznur Caliskan-Aydogan
- Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI 48824, USA
- Global Alliance for Rapid Diagnostics (GARD), Michigan State University, East Lansing, MI 48824, USA
| | - Chloe Zaborney Kline
- Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI 48824, USA
| | - Evangelyn C Alocilja
- Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI 48824, USA
- Global Alliance for Rapid Diagnostics (GARD), Michigan State University, East Lansing, MI 48824, USA
| |
Collapse
|
2
|
Liu Y, Raymond JJ, Wu X, Chua PWL, Ling SYH, Chan CC, Chan C, Loh JXY, Song MXY, Ong MYY, Ho P, Mcbee ME, Springs SL, Yu H, Han J. Electrostatic microfiltration (EM) enriches and recovers viable microorganisms at low-abundance in large-volume samples and enhances downstream detection. LAB ON A CHIP 2024; 24:4275-4287. [PMID: 39189168 DOI: 10.1039/d4lc00419a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/28/2024]
Abstract
Rapid and sensitive detection of pathogens in various samples is crucial for disease diagnosis, environmental surveillance, as well as food and water safety monitoring. However, the low abundance of pathogens (<10 CFU) in large volume (1 mL-1 L) samples containing vast backgrounds critically limits the sensitivity of even the most advanced techniques, such as digital PCR. Therefore, there is a critical need for sample preparation that can enrich low-abundance pathogens from complex and large-volume samples. This study develops an efficient electrostatic microfiltration (EM)-based sample preparation technique capable of processing ultra-large-volume (≥500 mL) samples at high throughput (≥10 mL min-1). This approach achieves a significant enrichment (>8000×) of extremely-low-abundance pathogens (down to level of 0.02 CFU mL-1, i.e., 10 CFU in 500 mL). Furthermore, EM-enabled sample preparation facilitates digital amplification techniques sensitively detecting broad pathogens, including bacteria, fungi, and viruses from various samples, in a rapid (≤3 h) sample-to-result workflow. Notably, the operational ease, portability, and compatibility/integrability with various downstream detection platforms highlight its great potential for widespread applications across diverse settings.
Collapse
Affiliation(s)
- Yaoping Liu
- AntiMicrobial Resistance (AMR) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Joshua J Raymond
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Xiaolin Wu
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Patrina Wei Lin Chua
- AntiMicrobial Resistance (AMR) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Sharon Yan Han Ling
- AntiMicrobial Resistance (AMR) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Chia Ching Chan
- AntiMicrobial Resistance (AMR) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Cheryl Chan
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Joanne Xin Yi Loh
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Melody Xing Yen Song
- School of Life Sciences & Chemical Technology, Ngee Ann Polytechnic, 599489, Singapore
| | - Matilda Yu Yan Ong
- School of Life Sciences & Chemical Technology, Ngee Ann Polytechnic, 599489, Singapore
| | - Peiying Ho
- AntiMicrobial Resistance (AMR) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Megan E Mcbee
- AntiMicrobial Resistance (AMR) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Stacy L Springs
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
- Center for Biomedical Innovation, Massachusetts Institute of Technology (MIT), MA 02139, USA
| | - Hanry Yu
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
- Institute of Bioengineering and Bioimaging (IBB), A*STAR, 138632, Singapore
- Department of physiology and WisDM and Mechanobiology Institute, National University of Singapore, 119077, Singapore
| | - Jongyoon Han
- AntiMicrobial Resistance (AMR) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
- Center for Biomedical Innovation, Massachusetts Institute of Technology (MIT), MA 02139, USA
- Department of Electrical Engineering and Computer Science, MIT, Cambridge, MA 02139, USA
- Department of Biological Engineering, MIT, Cambridge, MA 02139, USA.
| |
Collapse
|
3
|
Norouzy N, Zabihihesari A, Rezai P. Simultaneous high-throughput particle-bacteria separation and solution exchange via in-plane and out-of-plane parallelization of microfluidic centrifuges. BIOMICROFLUIDICS 2024; 18:054107. [PMID: 39345266 PMCID: PMC11435783 DOI: 10.1063/5.0215930] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Accepted: 08/20/2024] [Indexed: 10/01/2024]
Abstract
Inertial microfluidic devices have gained attention for point-of-need (PoN) sample preparation. Yet, devices capable of simultaneous particle-bacteria solution exchange and separation are low in throughput, hindering their applicability to PoN settings. This paper introduces a microfluidic centrifuge for high-throughput solution exchange and separation of microparticles, addressing the need for processing large sample volumes at elevated flow rates. The device integrates Dean flow recirculation and inertial focusing of microparticles within 24 curved microchannels assembled in a three-layer configuration via in-plane and out-of-plane parallelization. We studied solution exchange and particle migration using singleplex and duplex samples across devices with varying curve numbers (2-curve, 8-curve, and 24-curve). Processing 5 and 10 μm microparticles at flow rates up to 16.8 ml/min achieved a solution exchange efficiency of 96.69%. In singleplex solutions, 10 and 5 μm particles selectively migrated to inner and outer outlets, demonstrating separation efficiencies of 99.7% and 90.3%, respectively. With duplex samples, sample purity was measured to be 93.4% and 98.6% for 10 and 5 μm particles collected from the inner and the outer outlets, respectively. Application of our device in biological assays was shown by performing duplex experiments where 10 μm particles were isolated from Salmonella bacterial suspension with purity of 97.8% while increasing the state-of-the-art particle solution exchange and separation throughput by 16 folds. This parallelization enabled desirable combinations of high throughput, low-cost, and scalability, without compromising efficiency and purity, paving the way for sample preparation at the PoN in the future.
Collapse
Affiliation(s)
- Nima Norouzy
- Department of Mechanical Engineering, York University, BRG 433B, 4700 Keele St., Toronto, Ontario M3J 1P3, Canada
| | - Alireza Zabihihesari
- Department of Mechanical Engineering, York University, BRG 433B, 4700 Keele St., Toronto, Ontario M3J 1P3, Canada
| | - Pouya Rezai
- Department of Mechanical Engineering, York University, BRG 433B, 4700 Keele St., Toronto, Ontario M3J 1P3, Canada
| |
Collapse
|
4
|
Morecchiato F, Coppi M, Chilleri C, Antonelli A, Giani T, Rossolini GM. Evaluation of Quantamatrix dRAST TM system for rapid antimicrobial susceptibility testing of bacterial isolates from positive blood cultures, in comparison with commercial Micronaut broth microdilution system. Diagn Microbiol Infect Dis 2024; 110:116436. [PMID: 39003931 DOI: 10.1016/j.diagmicrobio.2024.116436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Revised: 07/10/2024] [Accepted: 07/10/2024] [Indexed: 07/16/2024]
Abstract
Antimicrobial susceptibility testing (AST) from blood culture (BC) may take several days, limiting the eventual impact on antimicrobial stewardship. Hence, rapid AST systems represent a valuable support in shorting the time-to-response. In this work, the Quantamatrix dRASTTM system (dRAST) was evaluated for rapid AST on 100 monomicrobial BCs (50 Gram-negatives and 50 Gram-positives), including several isolates with clinically relevant resistance mechanisms. AST results were provided in 6-hours, on average. Compared to Micronaut (Merlin) system based on broth microdilution, dRAST exhibited an overall categorical agreement of 92.5 %, essential agreement of 89.0 %, and mean bias of 15.9 %. Category overestimation (potentially leading to unnecessary high-dosage treatment or to exclude active agents) and category underestimation (potentially leading to underdosing or using ineffective agents) were observed in 4.3 % and 3.1 % of cases, respectively. Even though several issues were reported, results confirmed the potential contribution of dRAST to shorten the BCs clinical microbiology workflow and management.
Collapse
Affiliation(s)
- Fabio Morecchiato
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Marco Coppi
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy; Microbiology and Virology Unit, Careggi University Hospital, Florence, Italy
| | - Chiara Chilleri
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy; Microbiology and Virology Unit, Careggi University Hospital, Florence, Italy
| | - Alberto Antonelli
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy; Microbiology and Virology Unit, Careggi University Hospital, Florence, Italy
| | - Tommaso Giani
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy; Microbiology and Virology Unit, Careggi University Hospital, Florence, Italy
| | - Gian Maria Rossolini
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy; Microbiology and Virology Unit, Careggi University Hospital, Florence, Italy.
| |
Collapse
|
5
|
Islam Sajib MS, Brunker K, Oravcova K, Everest P, Murphy ME, Forde T. Advances in Host Depletion and Pathogen Enrichment Methods for Rapid Sequencing-Based Diagnosis of Bloodstream Infection. J Mol Diagn 2024; 26:741-753. [PMID: 38925458 DOI: 10.1016/j.jmoldx.2024.05.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 05/05/2024] [Accepted: 05/17/2024] [Indexed: 06/28/2024] Open
Abstract
Bloodstream infection is a major cause of morbidity and death worldwide. Timely and appropriate treatment can reduce mortality among critically ill patients. Current diagnostic methods are too slow to inform precise antibiotic choice, leading to the prescription of empirical antibiotics, which may fail to cover the resistance profile of the pathogen, risking poor patient outcomes. Additionally, overuse of broad-spectrum antibiotics may lead to more resistant organisms, putting further pressure on the dwindling pipeline of antibiotics, and risk transmission of these resistant organisms in the health care environment. Therefore, rapid diagnostics are urgently required to better inform antibiotic choice early in the course of treatment. Sequencing offers great promise in reducing time to microbiological diagnosis; however, the amount of host DNA compared with the pathogen in patient samples presents a significant obstacle. Various host-depletion and bacterial-enrichment strategies have been used in samples, such as saliva, urine, or tissue. However, these methods have yet to be collectively integrated and/or extensively explored for rapid bloodstream infection diagnosis. Although most of these workflows possess individual strengths, their lack of analytical/clinical sensitivity and/or comprehensiveness demands additional improvements or synergistic application. This review provides a distinctive classification system for various methods based on their working principles to guide future research, and discusses their strengths and limitations and explores potential avenues for improvement to assist the reader in workflow selection.
Collapse
Affiliation(s)
- Mohammad S Islam Sajib
- School of Biodiversity, One Health and Veterinary Medicine, University of Glasgow, Glasgow, United Kingdom.
| | - Kirstyn Brunker
- School of Biodiversity, One Health and Veterinary Medicine, University of Glasgow, Glasgow, United Kingdom; Medical Research Council-University of Glasgow Centre for Virus Research, Glasgow, United Kingdom
| | - Katarina Oravcova
- School of Biodiversity, One Health and Veterinary Medicine, University of Glasgow, Glasgow, United Kingdom
| | - Paul Everest
- School of Biodiversity, One Health and Veterinary Medicine, University of Glasgow, Glasgow, United Kingdom
| | - Michael E Murphy
- Department of Microbiology, National Health Service Greater Glasgow and Clyde, Glasgow, United Kingdom; School of Medicine, Dentistry and Nursing, University of Glasgow, Glasgow, United Kingdom
| | - Taya Forde
- School of Biodiversity, One Health and Veterinary Medicine, University of Glasgow, Glasgow, United Kingdom
| |
Collapse
|
6
|
Vaishnav MS, Pd D, Hegadi SS, C D, Murthy KNC, Srikanta S, Prasad R S. Accelerated microbial identification "directly" from positive blood cultures using MALDI-TOF MS: Local clinical laboratory challenges. Diagn Microbiol Infect Dis 2024; 109:116306. [PMID: 38735146 DOI: 10.1016/j.diagmicrobio.2024.116306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2023] [Revised: 04/12/2024] [Accepted: 04/12/2024] [Indexed: 05/14/2024]
Abstract
Rapid identification of microbial pathogens "directly" from positive blood cultures (PBCs) is critical for prompt initiation of empirical antibiotic therapy and clinical outcomes. Towards higher microbial identification rates, we modified a published initial serum separator tubes-based MALDI-TOF-MS protocol, for blood culture specimens received at a non-hospital based standalone diagnostic laboratory, Bangalore, India: (a) "Initial" protocol #1: From 28 PBCs, identification= 39% (Gram-negative= 43%: Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa; Gram-positive: 36%: Enterococcus faecalis, Staphylococcus aureus, Staphylococcus haemolyticus); mis-identification= 14%; non-identification= 47%. (b) "Modified" protocol #2: Quality controls (ATCC colonies spiked in negative blood cultures) From 7 analysis, identification= 100% (Escherichia coli, Klebsiella pneumonia, Klebsiella oxytoca, Pseudomonas aeruginosa, Enterococcus faecalis, Staphylococcus aureus); From 7 PBCs, identification= 57%; mis-identification= 14%; non-identification= 29%. Microbial preparations of highest quality and quantity for proteomic analysis and separate spectra matching reference databases for colonies and PBCs are needed for best clinical utility.
Collapse
Affiliation(s)
- Madhumati S Vaishnav
- Neuberg Anand Academy of Laboratory Medicine (NAALM), Bengaluru, India; Samatvam Endocrinology Diabetes Center, Jnana Sanjeevini Diabetes Hospital and Medical Center, Bengaluru, India.
| | - Deepalakshmi Pd
- Neuberg Anand Academy of Laboratory Medicine (NAALM), Bengaluru, India; Neuberg Anand Reference Laboratories (NARL), Bengaluru, India
| | - Sneha S Hegadi
- Neuberg Anand Reference Laboratories (NARL), Bengaluru, India
| | - Divya C
- Neuberg Anand Reference Laboratories (NARL), Bengaluru, India
| | | | - Sathyanarayana Srikanta
- Samatvam Endocrinology Diabetes Center, Jnana Sanjeevini Diabetes Hospital and Medical Center, Bengaluru, India
| | - Sujay Prasad R
- Neuberg Anand Academy of Laboratory Medicine (NAALM), Bengaluru, India; Neuberg Anand Reference Laboratories (NARL), Bengaluru, India
| |
Collapse
|
7
|
Gravemann U, Handke W, Schulze TJ, Seltsam A. Growth and Distribution of Bacteria in Contaminated Whole Blood and Derived Blood Components. Transfus Med Hemother 2024; 51:76-83. [PMID: 38584696 PMCID: PMC10996057 DOI: 10.1159/000536242] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Accepted: 01/10/2024] [Indexed: 04/09/2024] Open
Abstract
Introduction Bacterial contamination of blood products presumably occurs mainly during blood collection, starting from low initial concentrations of 10-100 colony-forming units (CFUs) per bag. As little is known about bacterial growth behavior and distribution in stored whole blood (WB) and WB-derived blood products, this study aims to provide data on this subject. Methods WB units were inoculated with transfusion-relevant bacterial species (Acinetobacter baumannii, Bacillus cereus, Escherichia coli, Klebsiella pneumoniae, Listeria monocytogenes, Pseudomonas fluorescens, Serratia marcescens, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus dysgalactiae, Streptococcus pyogenes, Yersinia enterocolitica; n = 12 for each species), stored for 22-24 h at room temperature, and then centrifuged for separation into plasma, red blood cells (RBCs), and buffy coats (BCs). The latter were pooled with 3 random donor BCs and one unit of PAS-E each to yield plasma-reduced platelet concentrates (PCs). Samples for bacterial colony counting were collected after WB storage and immediately after blood component production. Sterility testing in PCs (n = 12 for each species) was performed by bacterial culture after 7 days of storage. Results Bacterial growth in WB varied remarkably between donations and species. Streptococcus species produced the highest titers in WB, whereas Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, and Pseudomonas fluorescens did not multiply. Centrifugation resulted in preferential accumulation of bacteria in BCs, with titers of up to 3.5 × 103 CFU/mL in BCs and up to ≤0.9 × 103 CFU/mL in BC-derived PCs. Overall, 72/144 PCs (50%) tested positive for bacteria after storage. Sterility test results were species-dependent, ranging from 12 of 12 PCs tested positive for Streptococcus pyogenes to 1 of 12 PCs positive for Escherichia coli. Bacterial contamination of RBC and plasma units was much less common and was associated with higher initial bacterial counts in the parent WB units. Conclusions Bacterial growth in WB is species-dependent and varies greatly between donations. Preferential accumulation of bacteria in BCs during manufacturing is a critical determinant of the contamination risk of BC-derived pooled PCs.
Collapse
Affiliation(s)
- Ute Gravemann
- German Red Cross Blood Service NSTOB, Institute Springe, Springe, Germany
| | - Wiebke Handke
- Bavarian Red Cross Blood Service, Institute Nuremberg, Nuremberg, Germany
| | - Torsten J. Schulze
- German Red Cross Blood Service NSTOB, Institute Springe, Springe, Germany
| | - Axel Seltsam
- Bavarian Red Cross Blood Service, Institute Nuremberg, Nuremberg, Germany
| |
Collapse
|
8
|
Iyengar SN, Robinson JP. Spectral analysis and sorting of microbial organisms using a spectral sorter. Methods Cell Biol 2024; 186:189-212. [PMID: 38705599 DOI: 10.1016/bs.mcb.2024.02.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/07/2024]
Abstract
This chapter discusses the problems related to the application of conventional flow cytometers to microbiology. To address some of those limitations, the concept of spectral flow cytometry is introduced and the advantages over conventional flow cytometry for bacterial sorting are presented. We demonstrate by using ThermoFisher's Bigfoot spectral sorter where the spectral signatures of different stains for staining bacteria are demonstrated with an example of performing unmixing on spectral datasets. In addition to the Bigfoot's spectral analysis, the special biosafety features of this instrument are discussed. Utilizing these biosafety features, the sorting and patterning at the single cell level is optimized using non-pathogenic bacteria. Finally, the chapter is concluded by presenting a novel, label free, non-destructive, and rapid phenotypic method called Elastic Light Scattering (ELS) technology for identification of the patterned bacterial cells based on their unique colony scatter patterns.
Collapse
Affiliation(s)
- Sharath Narayana Iyengar
- Department of Basic Medical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, IN, United States
| | - J Paul Robinson
- Department of Basic Medical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, IN, United States; Weldon School of Biomedical Engineering, College of Engineering, Purdue University, West Lafayette, IN, United States.
| |
Collapse
|
9
|
Lehnert T, Gijs MAM. Microfluidic systems for infectious disease diagnostics. LAB ON A CHIP 2024; 24:1441-1493. [PMID: 38372324 DOI: 10.1039/d4lc00117f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/20/2024]
Abstract
Microorganisms, encompassing both uni- and multicellular entities, exhibit remarkable diversity as omnipresent life forms in nature. They play a pivotal role by supplying essential components for sustaining biological processes across diverse ecosystems, including higher host organisms. The complex interactions within the human gut microbiota are crucial for metabolic functions, immune responses, and biochemical signalling, particularly through the gut-brain axis. Viruses also play important roles in biological processes, for example by increasing genetic diversity through horizontal gene transfer when replicating inside living cells. On the other hand, infection of the human body by microbiological agents may lead to severe physiological disorders and diseases. Infectious diseases pose a significant burden on global healthcare systems, characterized by substantial variations in the epidemiological landscape. Fast spreading antibiotic resistance or uncontrolled outbreaks of communicable diseases are major challenges at present. Furthermore, delivering field-proven point-of-care diagnostic tools to the most severely affected populations in low-resource settings is particularly important and challenging. New paradigms and technological approaches enabling rapid and informed disease management need to be implemented. In this respect, infectious disease diagnostics taking advantage of microfluidic systems combined with integrated biosensor-based pathogen detection offers a host of innovative and promising solutions. In this review, we aim to outline recent activities and progress in the development of microfluidic diagnostic tools. Our literature research mainly covers the last 5 years. We will follow a classification scheme based on the human body systems primarily involved at the clinical level or on specific pathogen transmission modes. Important diseases, such as tuberculosis and malaria, will be addressed more extensively.
Collapse
Affiliation(s)
- Thomas Lehnert
- Laboratory of Microsystems, École Polytechnique Fédérale de Lausanne, Lausanne, CH-1015, Switzerland.
| | - Martin A M Gijs
- Laboratory of Microsystems, École Polytechnique Fédérale de Lausanne, Lausanne, CH-1015, Switzerland.
| |
Collapse
|
10
|
Jeon H, Lee SH, Shin J, Song K, Ahn N, Park J. Elasto-inertial microfluidic separation of microspheres with submicron resolution at high-throughput. MICROSYSTEMS & NANOENGINEERING 2024; 10:15. [PMID: 38264707 PMCID: PMC10803301 DOI: 10.1038/s41378-023-00633-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 10/23/2023] [Accepted: 11/08/2023] [Indexed: 01/25/2024]
Abstract
Elasto-inertial microfluidic separation offers many advantages including high throughput and separation resolution. Even though the separation efficiency highly depends on precise control of the flow conditions, no concrete guidelines have been reported yet in elasto-inertial microfluidics. Here, we propose a dimensionless analysis for precise estimation of the microsphere behaviors across the interface of Newtonian and viscoelastic fluids. Reynolds number, modified Weissenberg number, and modified elastic number are used to investigate the balance between inertial and elastic lift forces. Based on the findings, we introduce a new dimensionless number defined as the width of the Newtonian fluid stream divided by microsphere diameter. The proposed dimensionless analysis allows us to predict whether the microspheres migrate across the co-flow interface. The theoretical estimation is found to be in good agreement with the experimental results using 2.1- and 3.2-μm-diameter polystyrene microspheres in a co-flow of water and polyethylene oxide solution. Based on the theoretical estimation, we also realize submicron separation of the microspheres with 2.1 and 2.5 μm in diameter at high throughput, high purity (>95%), and high recovery rate (>97%). The applicability of the proposed method was validated by separation of platelets from similar-sized Escherichia coli (E.coli).
Collapse
Affiliation(s)
- Hyunwoo Jeon
- Department of Mechanical Engineering, Chonnam National University, 77 Yongbong-ro Buk-gu, Gwangju, 61186 Republic of Korea
| | - Song Ha Lee
- Department of Mechanical Engineering, Chonnam National University, 77 Yongbong-ro Buk-gu, Gwangju, 61186 Republic of Korea
| | - Jongho Shin
- Analytical Engineering Team, Samsung Display Co., Ltd., 181 Samsung-ro, Tangjeong-myeon, Asan-si, Chungcheongnam-do, 31454 Republic of Korea
| | - Kicheol Song
- Analytical Engineering Team, Samsung Display Co., Ltd., 181 Samsung-ro, Tangjeong-myeon, Asan-si, Chungcheongnam-do, 31454 Republic of Korea
| | - Nari Ahn
- Analytical Engineering Team, Samsung Display Co., Ltd., 181 Samsung-ro, Tangjeong-myeon, Asan-si, Chungcheongnam-do, 31454 Republic of Korea
| | - Jinsoo Park
- Department of Mechanical Engineering, Chonnam National University, 77 Yongbong-ro Buk-gu, Gwangju, 61186 Republic of Korea
| |
Collapse
|
11
|
Chu PY, Yang CM, Huang KL, Wu AY, Hsieh CH, Chao AC, Wu MH. Development of an Optically Induced Dielectrophoresis (ODEP) Microfluidic System for High-Performance Isolation and Purification of Bacteria. BIOSENSORS 2023; 13:952. [PMID: 37998128 PMCID: PMC10669672 DOI: 10.3390/bios13110952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 10/13/2023] [Accepted: 10/24/2023] [Indexed: 11/25/2023]
Abstract
For the rapid detection of bacteria in a blood sample, nucleic acid amplification-based assays are believed to be promising. Nevertheless, the nucleic acids released from the dead blood cells or bacteria could affect the assay performance. This highlights the importance of the isolation of live bacteria from blood samples. To address this issue, this study proposes a two-step process. First, a blood sample was treated with the immuno-magnetic microbeads-based separation to remove the majority of blood cells. Second, an optically induced dielectrophoresis (ODEP) microfluidic system with an integrated dynamic circular light image array was utilized to further isolate and purify the live bacteria from the remaining blood cells based on their size difference. In this work, the ODEP microfluidic system was developed. Its performance for the isolation and purification of bacteria was evaluated. The results revealed that the method was able to harvest the live bacteria in a high purity (90.5~99.2%) manner. Overall, the proposed method was proven to be capable of isolating and purifying high-purity live bacteria without causing damage to the co-existing cells. This technical feature was found to be valuable for the subsequent nucleic-acid-based bacteria detection, in which the interferences caused by the nontarget nucleic acids could be eliminated.
Collapse
Affiliation(s)
- Po-Yu Chu
- Graduate Institute of Biomedical Engineering, Chang Gung University, Taoyuan City 33302, Taiwan; (P.-Y.C.); (K.-L.H.); (A.-Y.W.)
| | - Chia-Ming Yang
- Department of Electronic Engineering, Chang Gung University, Taoyuan City 33302, Taiwan;
- Institute of Electro-Optical Engineering, Chang Gung University, Taoyuan City 33302, Taiwan
- Biosensor Group, Biomedical Engineering Research Center, Chang Gung University, Taoyuan City 33302, Taiwan
- Department of Neurosurgery, Chang Gung Memorial Hospital at Linkou, Taoyuan City 33302, Taiwan
- Department of Materials Engineering, Ming Chi University of Technology, New Taipei City 243303, Taiwan
| | - Kai-Lin Huang
- Graduate Institute of Biomedical Engineering, Chang Gung University, Taoyuan City 33302, Taiwan; (P.-Y.C.); (K.-L.H.); (A.-Y.W.)
| | - Ai-Yun Wu
- Graduate Institute of Biomedical Engineering, Chang Gung University, Taoyuan City 33302, Taiwan; (P.-Y.C.); (K.-L.H.); (A.-Y.W.)
| | - Chia-Hsun Hsieh
- Division of Hematology/Oncology, Department of Internal Medicine, Chang Gung Memorial Hospital at Linkou, Taoyuan City 33302, Taiwan;
- Division of Hematology/Oncology, Department of Internal Medicine, New Taipei Municipal TuCheng Hospital, New Taipei City 236017, Taiwan
| | - A-Ching Chao
- Department of Neurology, Kaohsiung Medical University Hospital, Kaohsiung City 80756, Taiwan
- Department of Neurology, College of Medicine, Kaohsiung Medical University, Kaohsiung City 80756, Taiwan
| | - Min-Hsien Wu
- Graduate Institute of Biomedical Engineering, Chang Gung University, Taoyuan City 33302, Taiwan; (P.-Y.C.); (K.-L.H.); (A.-Y.W.)
- Division of Hematology/Oncology, Department of Internal Medicine, Chang Gung Memorial Hospital at Linkou, Taoyuan City 33302, Taiwan;
- Division of Hematology/Oncology, Department of Internal Medicine, New Taipei Municipal TuCheng Hospital, New Taipei City 236017, Taiwan
| |
Collapse
|
12
|
Prinz Setter O, Jiang X, Segal E. Rising to the surface: capturing and detecting bacteria by rationally-designed surfaces. Curr Opin Biotechnol 2023; 83:102969. [PMID: 37494819 DOI: 10.1016/j.copbio.2023.102969] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 06/27/2023] [Accepted: 06/27/2023] [Indexed: 07/28/2023]
Abstract
Analytical microbiology has made substantial progress since its conception, starting from potato slices, through selective agar media, to engineered surfaces modified with capture probes. While the latter represents the dominant approach in designing sensors for bacteria detection, the importance of sensor surface properties is frequently ignored. Herein, we highlight their significant role in the complex process of bacterial transition from planktonic to sessile, representing the first and critical step in bacteria detection. We present the main surface features and discuss their effect on the bio-solid interface and the resulting sensing capabilities for both flat and particulate systems. The concepts of rationally-designed surfaces for enhanced bacterial detection are presented with recent examples of sensors (capture probe-free) relying solely on surface cues.
Collapse
Affiliation(s)
- Ofer Prinz Setter
- Department of Biotechnology and Food Engineering, Technion - Israel Institute of Technology, Technion City, 3200003 Haifa, Israel
| | - Xin Jiang
- Department of Biotechnology and Food Engineering, Technion - Israel Institute of Technology, Technion City, 3200003 Haifa, Israel
| | - Ester Segal
- Department of Biotechnology and Food Engineering, Technion - Israel Institute of Technology, Technion City, 3200003 Haifa, Israel; The Russel Berrie Nanotechnology Institute, Technion - Israel Institute of Technology, Technion City, 3200003 Haifa, Israel.
| |
Collapse
|
13
|
Zhu M, Xu T, Cheng Y, Ma B, Xu J, Diao Z, Wu F, Dai J, Han X, Zhu P, Pang C, Li J, Wang H, Xu R, Li X. Integrated Microfluidic Chip for Rapid Antimicrobial Susceptibility Testing Directly from Positive Blood Cultures. Anal Chem 2023; 95:14375-14383. [PMID: 37710979 DOI: 10.1021/acs.analchem.3c02737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/16/2023]
Abstract
Rapid and accurate antimicrobial prescriptions are critical for bloodstream infection (BSI) patients, as they can guide drug use and decrease mortality significantly. The traditional antimicrobial susceptibility testing (AST) for BSI is time-consuming and tedious, taking 2-3 days. Avoiding lengthy monoclonal cultures and shortening the drug sensitivity incubation time are keys to accelerating the AST. Here, we introduced a bacteria separation integrated AST (BSI-AST) chip, which could extract bacteria directly from positive blood cultures (PBCs) within 10 min and quickly give susceptibility information within 3 h. The integrated chip includes a bacteria separation chamber, multiple AST chambers, and connection channels. The separator gel was first preloaded into the bacteria separation chamber, enabling the swift separation of bacteria cells from PBCs through on-chip centrifugation. Then, the bacteria suspension was distributed in the AST chambers with preloaded antibiotics through a quick vacuum-assisted aliquoting strategy. Through centrifuge-assisted on-chip enrichment, detectable growth of the phenotype under different antibiotics could be easily observed in the taper tips of AST chambers within a few hours. As a proof of concept, direct AST from artificial PBCs with Escherichia coli against 18 antibiotics was performed on the BSI-AST chip, and the whole process from bacteria extraction to AST result output was less than 3.5 h. Moreover, the integrated chip was successfully applied to the diagnosis of clinical PBCs, showing 93.3% categorical agreement with clinical standard methods. The reliable and fast pathogen characterization of the integrated chip suggested its great potential application in clinical diagnosis.
Collapse
Affiliation(s)
- Meijia Zhu
- School of Environmental Science and Engineering, Institute of Eco-Environmental Forensics, Shandong University (Qingdao), Qingdao, Shandong 266237, China
| | - Teng Xu
- Single-Cell Center, CAS Key Laboratory of Biofuels, Shandong Key Laboratory of Energy Genetics, Shandong Energy Institute, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao, Shandong 266101, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yongqiang Cheng
- School of Environmental Science and Engineering, Institute of Eco-Environmental Forensics, Shandong University (Qingdao), Qingdao, Shandong 266237, China
| | - Bo Ma
- Single-Cell Center, CAS Key Laboratory of Biofuels, Shandong Key Laboratory of Energy Genetics, Shandong Energy Institute, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao, Shandong 266101, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jian Xu
- Single-Cell Center, CAS Key Laboratory of Biofuels, Shandong Key Laboratory of Energy Genetics, Shandong Energy Institute, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao, Shandong 266101, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Zhidian Diao
- Single-Cell Center, CAS Key Laboratory of Biofuels, Shandong Key Laboratory of Energy Genetics, Shandong Energy Institute, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao, Shandong 266101, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Fei Wu
- Single-Cell Center, CAS Key Laboratory of Biofuels, Shandong Key Laboratory of Energy Genetics, Shandong Energy Institute, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao, Shandong 266101, China
| | - Jing Dai
- Single-Cell Center, CAS Key Laboratory of Biofuels, Shandong Key Laboratory of Energy Genetics, Shandong Energy Institute, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao, Shandong 266101, China
| | - Xiao Han
- Single-Cell Center, CAS Key Laboratory of Biofuels, Shandong Key Laboratory of Energy Genetics, Shandong Energy Institute, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao, Shandong 266101, China
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan, Shandong 250024, China
| | - Pengfei Zhu
- Single-Cell Center, CAS Key Laboratory of Biofuels, Shandong Key Laboratory of Energy Genetics, Shandong Energy Institute, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao, Shandong 266101, China
- Qingdao Single Cell Biotechnology Company Limited, Qingdao, Shandong 266000, China
| | - Chao Pang
- Single-Cell Center, CAS Key Laboratory of Biofuels, Shandong Key Laboratory of Energy Genetics, Shandong Energy Institute, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao, Shandong 266101, China
| | - Jing Li
- Department of Clinical Laboratory, The Affiliated Hospital of Qingdao University, Qingdao, Shandong 266003, China
| | - Hongwei Wang
- Department of Clinical Laboratory, The Affiliated Hospital of Qingdao University, Qingdao, Shandong 266003, China
| | - Ranran Xu
- School of Environmental Science and Engineering, Institute of Eco-Environmental Forensics, Shandong University (Qingdao), Qingdao, Shandong 266237, China
| | - Xiaotong Li
- School of Environmental Science and Engineering, Institute of Eco-Environmental Forensics, Shandong University (Qingdao), Qingdao, Shandong 266237, China
| |
Collapse
|
14
|
Zeng K, Osaid M, van der Wijngaart W. Efficient filter-in-centrifuge separation of low-concentration bacteria from blood. LAB ON A CHIP 2023; 23:4334-4342. [PMID: 37712252 DOI: 10.1039/d3lc00594a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/16/2023]
Abstract
Separating bacteria from infected blood is an important step in preparing samples for downstream bacteria detection and analysis. However, the extremely low bacteria concentration and extremely high blood cell count make efficient separation challenging. In this study, we introduce a method for separating bacteria from blood in a single centrifugation step, which involves sedimentation velocity-based differentiation followed by size-based cross-flow filtration over an inclined filter. Starting from 1 mL spiked whole blood, we recovered 32 ± 4% of the bacteria (Escherichia coli, Klebsiella pneumonia, or Staphylococcus aureus) within one hour while removing 99.4 ± 0.1% of the red blood cells, 98.4 ± 1.4% of the white blood cells, and 90.0 ± 2.6% of the platelets. Changing the device material could further increase bacteria recovery to >50%. We demonstrated bacterial recovery from blood spiked with 10 CFU mL-1. Our simple hands-off efficient separation of low-abundant bacteria approaches clinical expectations, making the new method a promising candidate for future clinical use.
Collapse
Affiliation(s)
- Kaiyang Zeng
- Division of Micro and Nanosystems, KTH Royal Institute of Technology, Stockholm, Sweden.
| | - Mohammad Osaid
- Division of Micro and Nanosystems, KTH Royal Institute of Technology, Stockholm, Sweden.
| | | |
Collapse
|
15
|
Caliskan-Aydogan O, Sharief SA, Alocilja EC. Rapid Isolation of Low-Level Carbapenem-Resistant E. coli from Water and Foods Using Glycan-Coated Magnetic Nanoparticles. BIOSENSORS 2023; 13:902. [PMID: 37887095 PMCID: PMC10605215 DOI: 10.3390/bios13100902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 09/14/2023] [Accepted: 09/15/2023] [Indexed: 10/28/2023]
Abstract
Carbapenem-resistant Enterobacterales (CRE) are one of the major global issues needing attention. Among them, carbapenemase-producing (CP) E. coli strains are commonly found in clinical and biological samples. Rapid and cost-effective detection of such strains is critical in minimizing their deleterious impact. While promising progress is being made in rapid detection platforms, separation and enrichment of bacteria are required to ensure the detection of low bacterial counts. The current separation methods, such as centrifugation, filtration, electrophoresis, and immunomagnetic separation, are often tedious, expensive, or ineffective for clinical and biological samples. Further, the extraction and concentration of antimicrobial-resistant bacteria (ARB) are not well documented. Thus, this study assessed the applicability of cost-effective glycan-coated magnetic nanoparticles (gMNPs) for simple and rapid extraction of CP E. coli. The study included two resistant (R)strains: Klebsiella pneumoniae carbapenemase (KPC)-producing E. coli (R: KPC) and New Delhi metallo-β-lactamase (NDM)-producing E. coli (R: NDM). A susceptible E. coli (S) strain was used as a control, a reference bacterium. The gMNPs successfully extracted and concentrated E. coli (R) and E. coli (S) at low concentrations from large volumes of buffer solution, water, and food samples. The gMNPs concentrated up to two and five times their initial concentration for E. coli (R) and E. coli (S) in the buffer solution, respectively. In water and food samples, the concentration of E. coli (S) and E. coli (R) were similar and ranged 1-3 times their initial inoculation. A variation in the concentration from different food samples was seen, displaying the impact of food microstructure and natural microflora. The cost-effective and rapid bacterial cell capture by gMNPs was achieved in 15 min, and its successful binding to the bacterial cells in the buffer solution and food matrices was also confirmed using Transmission Electron Microscopy (TEM). These results show promising applications of gMNPs to extract pathogens and ARB from biological samples.
Collapse
Affiliation(s)
- Oznur Caliskan-Aydogan
- Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI 48824, USA; (O.C.-A.); (S.A.S.)
- Global Alliance for Rapid Diagnostics, Michigan State University, East Lansing, MI 48824, USA
| | - Saad Asadullah Sharief
- Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI 48824, USA; (O.C.-A.); (S.A.S.)
- Global Alliance for Rapid Diagnostics, Michigan State University, East Lansing, MI 48824, USA
| | - Evangelyn C. Alocilja
- Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI 48824, USA; (O.C.-A.); (S.A.S.)
- Global Alliance for Rapid Diagnostics, Michigan State University, East Lansing, MI 48824, USA
| |
Collapse
|
16
|
Robinson JP, Ostafe R, Iyengar SN, Rajwa B, Fischer R. Flow Cytometry: The Next Revolution. Cells 2023; 12:1875. [PMID: 37508539 PMCID: PMC10378642 DOI: 10.3390/cells12141875] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 07/06/2023] [Accepted: 07/13/2023] [Indexed: 07/30/2023] Open
Abstract
Unmasking the subtleties of the immune system requires both a comprehensive knowledge base and the ability to interrogate that system with intimate sensitivity. That task, to a considerable extent, has been handled by an iterative expansion in flow cytometry methods, both in technological capability and also in accompanying advances in informatics. As the field of fluorescence-based cytomics matured, it reached a technological barrier at around 30 parameter analyses, which stalled the field until spectral flow cytometry created a fundamental transformation that will likely lead to the potential of 100 simultaneous parameter analyses within a few years. The simultaneous advance in informatics has now become a watershed moment for the field as it competes with mature systematic approaches such as genomics and proteomics, allowing cytomics to take a seat at the multi-omics table. In addition, recent technological advances try to combine the speed of flow systems with other detection methods, in addition to fluorescence alone, which will make flow-based instruments even more indispensable in any biological laboratory. This paper outlines current approaches in cell analysis and detection methods, discusses traditional and microfluidic sorting approaches as well as next-generation instruments, and provides an early look at future opportunities that are likely to arise.
Collapse
Affiliation(s)
- J Paul Robinson
- Department of Basic Medical Sciences, Purdue University, West Lafayette, IN 47907, USA
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA
| | - Raluca Ostafe
- Molecular Evolution, Protein Engineering and Production Facility (PI4D), Purdue University, West Lafayette, IN 47907, USA
| | | | - Bartek Rajwa
- Bindley Bioscience Center, Purdue University, West Lafayette, IN 47907, USA
| | - Rainer Fischer
- Department of Comparative Pathobiology, College of Veterinary Medicine, Purdue University, West Lafayette, IN 47907, USA
- Purdue Institute of Inflammation, Immunology and Infectious Diseases, Purdue University, West Lafayette, IN 47907, USA
| |
Collapse
|
17
|
Caliskan-Aydogan O, Alocilja EC. A Review of Carbapenem Resistance in Enterobacterales and Its Detection Techniques. Microorganisms 2023; 11:1491. [PMID: 37374993 PMCID: PMC10305383 DOI: 10.3390/microorganisms11061491] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 05/23/2023] [Accepted: 05/25/2023] [Indexed: 06/29/2023] Open
Abstract
Infectious disease outbreaks have caused thousands of deaths and hospitalizations, along with severe negative global economic impacts. Among these, infections caused by antimicrobial-resistant microorganisms are a major growing concern. The misuse and overuse of antimicrobials have resulted in the emergence of antimicrobial resistance (AMR) worldwide. Carbapenem-resistant Enterobacterales (CRE) are among the bacteria that need urgent attention globally. The emergence and spread of carbapenem-resistant bacteria are mainly due to the rapid dissemination of genes that encode carbapenemases through horizontal gene transfer (HGT). The rapid dissemination enables the development of host colonization and infection cases in humans who do not use the antibiotic (carbapenem) or those who are hospitalized but interacting with environments and hosts colonized with carbapenemase-producing (CP) bacteria. There are continuing efforts to characterize and differentiate carbapenem-resistant bacteria from susceptible bacteria to allow for the appropriate diagnosis, treatment, prevention, and control of infections. This review presents an overview of the factors that cause the emergence of AMR, particularly CRE, where they have been reported, and then, it outlines carbapenemases and how they are disseminated through humans, the environment, and food systems. Then, current and emerging techniques for the detection and surveillance of AMR, primarily CRE, and gaps in detection technologies are presented. This review can assist in developing prevention and control measures to minimize the spread of carbapenem resistance in the human ecosystem, including hospitals, food supply chains, and water treatment facilities. Furthermore, the development of rapid and affordable detection techniques is helpful in controlling the negative impact of infections caused by AMR/CRE. Since delays in diagnostics and appropriate antibiotic treatment for such infections lead to increased mortality rates and hospital costs, it is, therefore, imperative that rapid tests be a priority.
Collapse
Affiliation(s)
- Oznur Caliskan-Aydogan
- Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI 48824, USA;
- Global Alliance for Rapid Diagnostics, Michigan State University, East Lansing, MI 48824, USA
| | - Evangelyn C. Alocilja
- Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI 48824, USA;
- Global Alliance for Rapid Diagnostics, Michigan State University, East Lansing, MI 48824, USA
| |
Collapse
|
18
|
Marutescu LG. Current and Future Flow Cytometry Applications Contributing to Antimicrobial Resistance Control. Microorganisms 2023; 11:1300. [PMID: 37317273 DOI: 10.3390/microorganisms11051300] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 05/10/2023] [Accepted: 05/11/2023] [Indexed: 06/16/2023] Open
Abstract
Antimicrobial resistance is a global threat to human health and welfare, food safety, and environmental health. The rapid detection and quantification of antimicrobial resistance are important for both infectious disease control and public health threat assessment. Technologies such as flow cytometry can provide clinicians with the early information, they need for appropriate antibiotic treatment. At the same time, cytometry platforms facilitate the measurement of antibiotic-resistant bacteria in environments impacted by human activities, enabling assessment of their impact on watersheds and soils. This review focuses on the latest applications of flow cytometry for the detection of pathogens and antibiotic-resistant bacteria in both clinical and environmental samples. Novel antimicrobial susceptibility testing frameworks embedding flow cytometry assays can contribute to the implementation of global antimicrobial resistance surveillance systems that are needed for science-based decisions and actions.
Collapse
Affiliation(s)
- Luminita Gabriela Marutescu
- Department of Botany and Microbiology, Faculty of Biology, University of Bucharest, 91-95 Spl. Independentei, 050095 Bucharest, Romania
- Research Institute of the University of Bucharest, 050095 Bucharest, Romania
| |
Collapse
|
19
|
Spencer D, Li Y, Zhu Y, Sutton JM, Morgan H. Electrical Broth Micro-Dilution for Rapid Antibiotic Resistance Testing. ACS Sens 2023; 8:1101-1108. [PMID: 36820613 PMCID: PMC10043929 DOI: 10.1021/acssensors.2c02166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
Abstract
Rapid tests to assess the susceptibility of bacteria to antibiotics are required to inform antibiotic stewardship. We have developed a novel test, which measures changes in the impedance of a 100 nanoliter volume of bacterial suspension to determine an "electrical" minimum inhibitory concentration (eMIC). Two representative strains of Klebsiella pneumoniae, Acinetobacter baumannii, Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus were tested against a panel of frontline antibiotics with different modes of action (ciprofloxacin, doxycycline, colistin and imipenem, gentamicin, and ceftazidime). The eMIC measured at 1 h correlated strongly with a standard 24 h microbroth dilution MIC for all combinations of antibiotics and bacteria, allowing strains to be correctly assigned as sensitive or resistant measured in a fraction of the time.
Collapse
Affiliation(s)
- Daniel Spencer
- School of Electronics and Computer Science, and Institute for Life Sciences, University of Southampton, Hants, Southampton SO17 1BJ, U.K
| | - Yuetao Li
- School of Electronics and Computer Science, and Institute for Life Sciences, University of Southampton, Hants, Southampton SO17 1BJ, U.K
| | - Yiling Zhu
- Technology Development Group, Research and Evaluation, UK Health Security Agency (UKHSA), Porton, Salisbury SP4 0JG, U.K
| | - J Mark Sutton
- Technology Development Group, Research and Evaluation, UK Health Security Agency (UKHSA), Porton, Salisbury SP4 0JG, U.K
- Institute of Pharmaceutical Science, School of Cancer & Pharmaceutical Sciences, King's College London, Franklin-Wilkins Building, 150 Stamford Street, London SE1 9NH, U.K
| | - Hywel Morgan
- School of Electronics and Computer Science, and Institute for Life Sciences, University of Southampton, Hants, Southampton SO17 1BJ, U.K
| |
Collapse
|
20
|
Weber MU, Petkowski JJ, Weber RE, Krajnik B, Stemplewski S, Panek M, Dziubak T, Mrozinska P, Piela A, Paluch E. Chip for dielectrophoretic microbial capture, separation and detection II: experimental study. NANOTECHNOLOGY 2023; 34:175502. [PMID: 36640445 DOI: 10.1088/1361-6528/acb321] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Accepted: 01/13/2023] [Indexed: 06/17/2023]
Abstract
In our previous paper we have modelled a dielectrophoretic force (DEP) and cell particle behavior in a microfluidic channel (Weber MUet al2023 Chip for dielectrophoretic microbial capture, separation and detection I: theoretical basis of electrode designNanotechnologythis issue). Here we test and confirm the results of our modeling work by experimentally validating the theoretical design constraints of the ring electrode architecture. We have compared and tested the geometry and particle capture and separation performance of the two separate electrode designs (the ring and dot electrode structures) by investigating bacterial motion in response to the applied electric field. We have quantitatively evaluated the electroosmosis (EO) to positive DEP (PDEP) transition in both electrode designs and explained the differences in capture efficiency of the ring and dot electrode systems. The ring structure shows 99% efficiency of bacterial capture both for PDEP and for EO. Moreover, the ring structure shows an over 200 faster bacterial response to the electric field. We have also established that the ring electrode architecture, with appropriate structure periodicity and spacing, results in efficient capture and separation of microbial cells. We have identified several critical design constraints that are required to achieve high efficiency bacterial capture. We have established that the spacing between consecutive DEP traps smaller than the length of the depletion zone will ensure that the DEP force dominates bacterial motion over motility and Brownian motion.
Collapse
Affiliation(s)
- Monika U Weber
- Departments of Electrical Engineering and Applied Physics, Yale University, 15 Prospect St., New Haven, CT 06520, United States of America
- Hener, Wrocław Technology Park, BETA Building, Room 104, Klecińska 125, 54-413, Wrocław, Poland
| | | | - Robert E Weber
- Hener, Wrocław Technology Park, BETA Building, Room 104, Klecińska 125, 54-413, Wrocław, Poland
| | - Bartosz Krajnik
- Hener, Wrocław Technology Park, BETA Building, Room 104, Klecińska 125, 54-413, Wrocław, Poland
- Department of Experimental Physics, Wroclaw University of Science and Technology, Wyb. S. Wyspianskiego 27, 50-370 Wroclaw, Poland
| | - Slawomir Stemplewski
- Hener, Wrocław Technology Park, BETA Building, Room 104, Klecińska 125, 54-413, Wrocław, Poland
- Institute of Computer Science, Opole University, ul. Oleska 48, 45-052, Opole, Poland
| | - Marta Panek
- Hener, Wrocław Technology Park, BETA Building, Room 104, Klecińska 125, 54-413, Wrocław, Poland
| | - Tomasz Dziubak
- Hener, Wrocław Technology Park, BETA Building, Room 104, Klecińska 125, 54-413, Wrocław, Poland
| | - Paulina Mrozinska
- Hener, Wrocław Technology Park, BETA Building, Room 104, Klecińska 125, 54-413, Wrocław, Poland
| | - Anna Piela
- Hener, Wrocław Technology Park, BETA Building, Room 104, Klecińska 125, 54-413, Wrocław, Poland
| | - Emil Paluch
- Hener, Wrocław Technology Park, BETA Building, Room 104, Klecińska 125, 54-413, Wrocław, Poland
- Department of Microbiology, Faculty of Medicine, Wroclaw Medical University, Tytusa Chałubińskiego 4, 50-376 Wrocław, Poland
| |
Collapse
|
21
|
Zhao J, Li Y, Chen X, Mu D, Zhao J, Zhou S. Sensitive NIR Fluorescence Identification of Bacteria in Whole Blood with Bioorthogonal Nanoprobes for Early Sepsis Diagnosis. Anal Chem 2023; 95:955-965. [PMID: 36573885 DOI: 10.1021/acs.analchem.2c03509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Sepsis is one of the leading causes of death worldwide. The disease progression of sepsis is very fast, and there is a 7-9% increase in mortality every hour. Therefore, rapid and sensitive detection of pathogenic bacteria is crucial for the timely treatment of sepsis as well as the reduction of mortality. Herein, we present a sensitive near-infrared (NIR) fluorescence identification and a rapid magnetic capture based on bioorthogonal nanoprobes for the detection of multiple bacteria in whole blood. The nanoprobes with NIR fluorescence/magnetic properties were modified with dibenzocyclooctyne groups and used to capture and recognize the bacteria via bioorthogonal reaction. The magnetic nanoprobes showed superparamagnetic properties with a saturation magnetization as high as 63 emu/g. Through clicking with the azide groups inserted on the bacteria walls by metabolic engineering, the bioorthogonal magnetic nanoprobes allow fast and broad-spectrum capture of both Gram-positive and Gram-negative bacteria. The bioorthogonal NIR fluorescent nanoprobes with a maximum emission at 900 nm can effectively avoid background interference, further enabling sensitive identification of the bacteria in whole blood. The detection limit was as low as 4 CFU/mL in less than 2.5 h and the nanoprobes were successfully applied to the detection of bacteria in blood samples from the patients with sepsis, showing the potential application in early sepsis diagnosis and clinical studies.
Collapse
Affiliation(s)
- Jinyan Zhao
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu610031, China
| | - Yingping Li
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu610031, China
| | - Xin Chen
- Department of Laboratory Medicine, The Third People's Hospital of Chengdu/Affiliated Hospital of Southwest Jiaotong University, Chengdu610031, China
| | - Dan Mu
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu610031, China
| | - Jingya Zhao
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu610031, China
| | - Shaobing Zhou
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu610031, China
| |
Collapse
|
22
|
Shrestha J, Razavi Bazaz S, Ding L, Vasilescu S, Idrees S, Söderström B, Hansbro PM, Ghadiri M, Ebrahimi Warkiani M. Rapid separation of bacteria from primary nasal samples using inertial microfluidics. LAB ON A CHIP 2022; 23:146-156. [PMID: 36484411 DOI: 10.1039/d2lc00794k] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Microbial populations play a crucial role in human health and the development of many diseases. These diseases often arise from the explosive proliferation of opportunistic bacteria, such as those in the nasal cavity. Recently, there have been increases in the prevalence of these opportunistic pathogens displaying antibiotic resistance. Thus, the study of the nasal microbiota and its bacterial diversity is critical in understanding pathogenesis and developing microbial-based therapies for well-known and emerging diseases. However, the isolation and analysis of these populations for clinical study complicates the already challenging task of identifying and profiling potentially harmful bacteria. Existing methods are limited by low sample throughput, expensive labeling, and low recovery of bacteria with ineffective removal of cells and debris. In this study, we propose a novel microfluidic channel with a zigzag configuration for enhanced isolation and detection of bacteria from human clinical nasal swabs. This microfluidic zigzag channel separates the bacteria from epithelial cells and debris by size differential focusing. As such, pure bacterial cell fractions devoid of large contaminating debris or epithelial cells are obtained. DNA sequencing performed on the separated bacteria defines the diversity and species present. This novel method of bacterial separation is simple, robust, rapid, and cost-effective and has the potential to be used for the rapid identification of bacterial cell populations from clinical samples.
Collapse
Affiliation(s)
- Jesus Shrestha
- School of Biomedical Engineering, University of Technology Sydney, Sydney, New South Wales 2007, Australia.
- Woolcock Institute of Medical Research, Respiratory Technology Group, University of Sydney, Sydney, New South Wales 2037, Australia
| | - Sajad Razavi Bazaz
- School of Biomedical Engineering, University of Technology Sydney, Sydney, New South Wales 2007, Australia.
| | - Lin Ding
- School of Biomedical Engineering, University of Technology Sydney, Sydney, New South Wales 2007, Australia.
| | - Steven Vasilescu
- School of Biomedical Engineering, University of Technology Sydney, Sydney, New South Wales 2007, Australia.
| | - Sobia Idrees
- Centre for Inflammation, Centenary Institute and University of Technology Sydney, Faculty of Science, School of Life Sciences, University of Technology Sydney, Sydney 2007, Australia
| | - Bill Söderström
- Australian Institute for Microbiology and Infection, Faculty of Science, University of Technology Sydney, New South Wales 2007, Australia
| | - Philip M Hansbro
- Centre for Inflammation, Centenary Institute and University of Technology Sydney, Faculty of Science, School of Life Sciences, University of Technology Sydney, Sydney 2007, Australia
| | - Maliheh Ghadiri
- School of Biomedical Engineering, University of Technology Sydney, Sydney, New South Wales 2007, Australia.
- Woolcock Institute of Medical Research, Respiratory Technology Group, University of Sydney, Sydney, New South Wales 2037, Australia
| | - Majid Ebrahimi Warkiani
- School of Biomedical Engineering, University of Technology Sydney, Sydney, New South Wales 2007, Australia.
- Institute for Biomedical Materials and Devices, Faculty of Science, University of Technology Sydney, New South Wales 2007, Australia
- Institute of Molecular Medicine, Sechenov First Moscow State University, Moscow 119991, Russia
| |
Collapse
|
23
|
Emmerich MEP, Sinnigen AS, Neubauer P, Birkholz M. Dielectrophoretic separation of blood cells. Biomed Microdevices 2022; 24:30. [PMID: 36006519 PMCID: PMC9411249 DOI: 10.1007/s10544-022-00623-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/07/2022] [Indexed: 11/02/2022]
Abstract
Microfluidic dielectrophoretic (DEP) devices enable the label-free separation and isolation of cells based on differences in their electrophysiological properties. The technique can serve as a tool in clinical diagnostics and medical research as it facilitates the analysis of patient-specific blood composition and the detection and isolation of pathogenic cells like circulating tumor cells or malaria-infected erythrocytes. This review compares different microfluidic DEP devices to separate platelets, erythrocytes and leukocytes including their cellular subclasses. An overview and experimental setups of different microfluidic DEP devices for the separation, trapping and isolation or purification of blood cells are detailed with respect to their technical design, electrode configuration, sample preparation, applied voltage and frequency and created DEP field based and related to the separation efficiency. The technique holds the promise that results can quickly be attained in clinical and ambulant settings. In particular, point-of-care-testing scenarios are favored by the extensive miniaturization, which would be enabled by microelectronical integration of DEP devices.
Collapse
Affiliation(s)
- Maria E. P. Emmerich
- Chair of Bioprocess Engineering, Institute of Biotechnology, TU Berlin, Ackerstrasse 76, ACK24, D-13355 Berlin, Germany
- IHP – Leibniz-Institut für innovative Mikroelektronik, Im Technologiepark 25, 15236 Frankfurt (Oder), Germany
| | - Anne-Sophie Sinnigen
- Chair of Bioprocess Engineering, Institute of Biotechnology, TU Berlin, Ackerstrasse 76, ACK24, D-13355 Berlin, Germany
| | - Peter Neubauer
- Chair of Bioprocess Engineering, Institute of Biotechnology, TU Berlin, Ackerstrasse 76, ACK24, D-13355 Berlin, Germany
| | - Mario Birkholz
- IHP – Leibniz-Institut für innovative Mikroelektronik, Im Technologiepark 25, 15236 Frankfurt (Oder), Germany
| |
Collapse
|
24
|
Haque ME, Marriott L, Naeem N, Henry T, Conde AJ, Kersaudy-Kerhoas M. A low-cost, open-source centrifuge adaptor for separating large volume clinical blood samples. PLoS One 2022; 17:e0266769. [PMID: 35802693 PMCID: PMC9269434 DOI: 10.1371/journal.pone.0266769] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Accepted: 03/26/2022] [Indexed: 11/18/2022] Open
Abstract
Blood plasma separation is a prerequisite in numerous biomedical assays involving low abundance plasma-borne biomarkers and thus is the fundamental step before many bioanalytical steps. High-capacity refrigerated centrifuges, which have the advantage of handling large volumes of blood samples, are widely utilized, but they are bulky, non-transportable, and prohibitively expensive for low-resource settings, with prices starting at $1,500. On the other hand, there are low-cost commercial and open-source micro-centrifuges available, but they are incapable of handling typical clinical amounts of blood samples (2-10mL). There is currently no low-cost CE marked centrifuge that can process large volumes of clinical blood samples on the market. As a solution, we customised the rotor of a commercially available low-cost micro-centrifuge (~$125) using 3D printing to enable centrifugation of large clinical blood samples in resource poor-settings. Our custom adaptor ($15) can hold two 9 mL S-Monovette tubes and achieve the same separation performance (yield, cell count, hemolysis, albumin levels) as the control benchtop refrigerated centrifuge, and even outperformed the control in platelet separation by at least four times. This low-cost open-source centrifugation system capable of processing clinical blood tubes could be valuable to low-resource settings where centrifugation is required immediately after blood withdrawal for further testing.
Collapse
Affiliation(s)
- Md Ehtashamul Haque
- Institute of Biological Chemistry, Biophysics and Bioengineering, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, United Kingdom
| | - Linda Marriott
- Institute of Biological Chemistry, Biophysics and Bioengineering, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, United Kingdom
| | - Noman Naeem
- Institute of Biological Chemistry, Biophysics and Bioengineering, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, United Kingdom
| | - Taygan Henry
- Institute of Biological Chemistry, Biophysics and Bioengineering, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, United Kingdom
| | - Alvaro J. Conde
- Institute of Biological Chemistry, Biophysics and Bioengineering, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, United Kingdom
- Micronit B.V., Enschede, Netherlands
| | - Maïwenn Kersaudy-Kerhoas
- Institute of Biological Chemistry, Biophysics and Bioengineering, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, United Kingdom
- Infection Medicine, College of Medicine and Veterinary Medicine, University of Edinburgh, Edinburgh, United Kingdom
- * E-mail:
| |
Collapse
|
25
|
Tjandra KC, Ram-Mohan N, Abe R, Hashemi MM, Lee JH, Chin SM, Roshardt MA, Liao JC, Wong PK, Yang S. Diagnosis of Bloodstream Infections: An Evolution of Technologies towards Accurate and Rapid Identification and Antibiotic Susceptibility Testing. Antibiotics (Basel) 2022; 11:511. [PMID: 35453262 PMCID: PMC9029869 DOI: 10.3390/antibiotics11040511] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 04/05/2022] [Accepted: 04/08/2022] [Indexed: 02/07/2023] Open
Abstract
Bloodstream infections (BSI) are a leading cause of death worldwide. The lack of timely and reliable diagnostic practices is an ongoing issue for managing BSI. The current gold standard blood culture practice for pathogen identification and antibiotic susceptibility testing is time-consuming. Delayed diagnosis warrants the use of empirical antibiotics, which could lead to poor patient outcomes, and risks the development of antibiotic resistance. Hence, novel techniques that could offer accurate and timely diagnosis and susceptibility testing are urgently needed. This review focuses on BSI and highlights both the progress and shortcomings of its current diagnosis. We surveyed clinical workflows that employ recently approved technologies and showed that, while offering improved sensitivity and selectivity, these techniques are still unable to deliver a timely result. We then discuss a number of emerging technologies that have the potential to shorten the overall turnaround time of BSI diagnosis through direct testing from whole blood-while maintaining, if not improving-the current assay's sensitivity and pathogen coverage. We concluded by providing our assessment of potential future directions for accelerating BSI pathogen identification and the antibiotic susceptibility test. While engineering solutions have enabled faster assay turnaround, further progress is still needed to supplant blood culture practice and guide appropriate antibiotic administration for BSI patients.
Collapse
Affiliation(s)
- Kristel C. Tjandra
- Department of Emergency Medicine, Stanford University School of Medicine, Palo Alto, CA 94305, USA; (K.C.T.); (N.R.-M.); (R.A.); (M.M.H.)
| | - Nikhil Ram-Mohan
- Department of Emergency Medicine, Stanford University School of Medicine, Palo Alto, CA 94305, USA; (K.C.T.); (N.R.-M.); (R.A.); (M.M.H.)
| | - Ryuichiro Abe
- Department of Emergency Medicine, Stanford University School of Medicine, Palo Alto, CA 94305, USA; (K.C.T.); (N.R.-M.); (R.A.); (M.M.H.)
| | - Marjan M. Hashemi
- Department of Emergency Medicine, Stanford University School of Medicine, Palo Alto, CA 94305, USA; (K.C.T.); (N.R.-M.); (R.A.); (M.M.H.)
| | - Jyong-Huei Lee
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA; (J.-H.L.); (S.M.C.); (M.A.R.); (P.K.W.)
| | - Siew Mei Chin
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA; (J.-H.L.); (S.M.C.); (M.A.R.); (P.K.W.)
| | - Manuel A. Roshardt
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA; (J.-H.L.); (S.M.C.); (M.A.R.); (P.K.W.)
| | - Joseph C. Liao
- Department of Urology, Stanford University School of Medicine, Stanford, CA 94305, USA;
- Veterans Affairs Palo Alto Health Care System, Palo Alto, CA 94304, USA
| | - Pak Kin Wong
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA; (J.-H.L.); (S.M.C.); (M.A.R.); (P.K.W.)
- Department of Mechanical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
- Department of Surgery, The Pennsylvania State University, Hershey, PA 17033, USA
| | - Samuel Yang
- Department of Emergency Medicine, Stanford University School of Medicine, Palo Alto, CA 94305, USA; (K.C.T.); (N.R.-M.); (R.A.); (M.M.H.)
| |
Collapse
|
26
|
Liu P, Liu H, Semenec L, Yuan D, Yan S, Cain AK, Li M. Length-based separation of Bacillus subtilis bacterial populations by viscoelastic microfluidics. MICROSYSTEMS & NANOENGINEERING 2022; 8:7. [PMID: 35127130 PMCID: PMC8766588 DOI: 10.1038/s41378-021-00333-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Revised: 11/08/2021] [Accepted: 11/09/2021] [Indexed: 06/14/2023]
Abstract
In this study, we demonstrated the label-free continuous separation and enrichment of Bacillus subtilis populations based on length using viscoelastic microfluidics. B. subtilis, a gram-positive, rod-shaped bacterium, has been widely used as a model organism and an industrial workhorse. B. subtilis can be arranged in different morphological forms, such as single rods, chains, and clumps, which reflect differences in cell types, phases of growth, genetic variation, and changing environmental factors. The ability to prepare B. subtilis populations with a uniform length is important for basic biological studies and efficient industrial applications. Here, we systematically investigated how flow rate ratio, poly(ethylene oxide) (PEO) concentration, and channel length affected the length-based separation of B. subtilis cells. The lateral positions of B. subtilis cells with varying morphologies in a straight rectangular microchannel were found to be dependent on cell length under the co-flow of viscoelastic and Newtonian fluids. Finally, we evaluated the ability of the viscoelastic microfluidic device to separate the two groups of B. subtilis cells by length (i.e., 1-5 μm and >5 μm) in terms of extraction purity (EP), extraction yield (EY), and enrichment factor (EF) and confirmed that the device could separate heterogeneous populations of bacteria using elasto-inertial effects.
Collapse
Affiliation(s)
- Ping Liu
- Suqian University, Suqian, 223800 China
- School of Engineering, Macquarie University, Sydney, NSW 2109 Australia
| | - Hangrui Liu
- Department of Physics and Astronomy, Macquarie University, Sydney, NSW 2109 Australia
| | - Lucie Semenec
- ARC Centre of Excellence in Synthetic Biology, Department of Molecular Science, Macquarie University, Sydney, NSW 2109 Australia
| | - Dan Yuan
- Centre for Regional and Rural Futures, Deakin University, Geelong, VIC 3216 Australia
| | - Sheng Yan
- Institute for Advanced Study, Shenzhen University, Shenzhen, 518060 China
| | - Amy K. Cain
- ARC Centre of Excellence in Synthetic Biology, Department of Molecular Science, Macquarie University, Sydney, NSW 2109 Australia
| | - Ming Li
- School of Engineering, Macquarie University, Sydney, NSW 2109 Australia
- Biomolecular Discovery Research Centre, Macquarie University, Sydney, NSW 2109 Australia
| |
Collapse
|
27
|
Fluid-Screen as a real time dielectrophoretic method for universal microbial capture. Sci Rep 2021; 11:22222. [PMID: 34782647 PMCID: PMC8594773 DOI: 10.1038/s41598-021-01600-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Accepted: 10/20/2021] [Indexed: 12/11/2022] Open
Abstract
Bacterial culture methods, e.g. Plate Counting Method (PCM), are a gold standard in the assessment of microbial contamination in multitude of human industries. They are however slow, labor intensive, and prone to manual errors. Dielectrophoresis (DEP) has shown great promise for particle separation for decades; however, it has not yet been widely applied in routine laboratory setting. This paper provides an overview of a new DEP microbial capture and separation method called Fluid-Screen (FS), that achieves very fast, efficient, reliable and repeatable capture and separation of microbial cells. Method verification experiments demonstrated that the FS system captured 100% of bacteria in test samples, a capture efficiency much higher than previously reported for similar technology. Data generated supports the superiority of the FS method as compared to the established Plate Counting Method (PCM), that is routinely used to detect bacterial contamination in healthcare, pharmacological and food industries. We demonstrate that the FS method is universal and can capture and separate different species of bacteria and fungi to viruses, from various sample matrices (i.e. human red blood cells, mammalian cells).
Collapse
|
28
|
Liu Y, Lehnert T, Gijs MAM. Effect of inoculum size and antibiotics on bacterial traveling bands in a thin microchannel defined by optical adhesive. MICROSYSTEMS & NANOENGINEERING 2021; 7:86. [PMID: 34745645 PMCID: PMC8536744 DOI: 10.1038/s41378-021-00309-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2021] [Revised: 09/02/2021] [Accepted: 09/03/2021] [Indexed: 06/13/2023]
Abstract
Phenotypic diversity in bacterial flagella-induced motility leads to complex collective swimming patterns, appearing as traveling bands with transient locally enhanced cell densities. Traveling bands are known to be a bacterial chemotactic response to self-generated nutrient gradients during growth in resource-limited microenvironments. In this work, we studied different parameters of Escherichia coli (E. coli) collective migration, in particular the quantity of bacteria introduced initially in a microfluidic chip (inoculum size) and their exposure to antibiotics (ampicillin, ciprofloxacin, and gentamicin). We developed a hybrid polymer-glass chip with an intermediate optical adhesive layer featuring the microfluidic channel, enabling high-content imaging of the migration dynamics in a single bacterial layer, i.e., bacteria are confined in a quasi-2D space that is fully observable with a high-magnification microscope objective. On-chip bacterial motility and traveling band analysis was performed based on individual bacterial trajectories by means of custom-developed algorithms. Quantifications of swimming speed, tumble bias and effective diffusion properties allowed the assessment of phenotypic heterogeneity, resulting in variations in transient cell density distributions and swimming performance. We found that incubation of isogeneic E. coli with different inoculum sizes eventually generated different swimming phenotype distributions. Interestingly, incubation with antimicrobials promoted bacterial chemotaxis in specific cases, despite growth inhibition. Moreover, E. coli filamentation in the presence of antibiotics was assessed, and the impact on motility was evaluated. We propose that the observation of traveling bands can be explored as an alternative for fast antimicrobial susceptibility testing.
Collapse
Affiliation(s)
- Yang Liu
- Laboratory of Microsystems, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland
| | - Thomas Lehnert
- Laboratory of Microsystems, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland
| | - Martin A. M. Gijs
- Laboratory of Microsystems, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland
| |
Collapse
|
29
|
Duncan JL, Davalos RV. A review: Dielectrophoresis for characterizing and separating similar cell subpopulations based on bioelectric property changes due to disease progression and therapy assessment. Electrophoresis 2021; 42:2423-2444. [PMID: 34609740 DOI: 10.1002/elps.202100135] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 09/19/2021] [Accepted: 09/23/2021] [Indexed: 12/16/2022]
Abstract
This paper reviews the use of dielectrophoresis for high-fidelity separations and characterizations of subpopulations to highlight the recent advances in the electrokinetic field as well as provide insight into its progress toward commercialization. The role of cell subpopulations in heterogeneous clinical samples has been studied to deduce their role in disease progression and therapy resistance for instances such as cancer, tissue regeneration, and bacterial infection. Dielectrophoresis (DEP), a label-free electrokinetic technique, has been used to characterize and separate target subpopulations from mixed samples to determine disease severity, cell stemness, and drug efficacy. Despite its high sensitivity to characterize similar or related cells based on their differing bioelectric signatures, DEP has been slowly adopted both commercially and clinically. This review addresses the use of dielectrophoresis for the identification of target cell subtypes in stem cells, cancer cells, blood cells, and bacterial cells dependent on cell state and therapy exposure and addresses commercialization efforts in light of its sensitivity and future perspectives of the technology, both commercially and academically.
Collapse
Affiliation(s)
- Josie L Duncan
- Bioelectromechanical Systems Laboratory, Department of Mechanical Engineering, Virginia Tech, Blacksburg, Virginia, USA.,Bioelectromechanical Systems Laboratory, Wake Forest School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, Virginia, USA
| | - Rafael V Davalos
- Bioelectromechanical Systems Laboratory, Department of Mechanical Engineering, Virginia Tech, Blacksburg, Virginia, USA.,Bioelectromechanical Systems Laboratory, Wake Forest School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, Virginia, USA
| |
Collapse
|
30
|
Narayana Iyengar S, Kumar T, Mårtensson G, Russom A. High resolution and rapid separation of bacteria from blood using elasto-inertial microfluidics. Electrophoresis 2021; 42:2538-2551. [PMID: 34510466 DOI: 10.1002/elps.202100140] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 08/27/2021] [Accepted: 09/06/2021] [Indexed: 12/13/2022]
Abstract
Improved sample preparation has the potential to address unmet needs for fast turnaround sepsis tests. In this work, we report elasto-inertial based rapid bacteria separation from diluted blood at high separation efficiency. In viscoelastic flows, we demonstrate novel findings where blood cells prepositioned at the outer wall entering a spiral device remain fully focused throughout the channel length while smaller bacteria migrate to the opposite wall. Initially, using microparticles, we show that particles above a certain size cut-off remain fully focused at the outer wall while smaller particles differentially migrate toward the inner wall. We demonstrate particle separation at 1 μm resolution at a total throughput of 1 mL/min. For blood-based experiments, a minimum of 1:2 dilution was necessary to fully focus blood cells at the outer wall. Finally, Escherichia coli spiked in diluted blood were continuously separated at a total flow rate of 1 mL/min, with efficiencies between 82 and 90% depending on the blood dilution. Using a single spiral, it takes 40 min to process 1 mL of blood at a separation efficiency of 82%. The label-free, passive, and rapid bacteria isolation method has a great potential for speeding up downstream phenotypic and genotypic analysis.
Collapse
Affiliation(s)
- Sharath Narayana Iyengar
- KTH Royal Institute of Technology, Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, Solna, Sweden.,AIMES-Center for the Advancement of Integrated Medical and Engineering Sciences at Karolinska Institutet and KTH Royal Institute of Technology, Stockholm, Sweden
| | - Tharagan Kumar
- KTH Royal Institute of Technology, Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, Solna, Sweden.,AIMES-Center for the Advancement of Integrated Medical and Engineering Sciences at Karolinska Institutet and KTH Royal Institute of Technology, Stockholm, Sweden
| | - Gustaf Mårtensson
- KTH Royal Institute of Technology, Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, Solna, Sweden
| | - Aman Russom
- KTH Royal Institute of Technology, Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, Solna, Sweden.,AIMES-Center for the Advancement of Integrated Medical and Engineering Sciences at Karolinska Institutet and KTH Royal Institute of Technology, Stockholm, Sweden
| |
Collapse
|
31
|
A Rapid Single-Cell Antimicrobial Susceptibility Testing Workflow for Bloodstream Infections. BIOSENSORS-BASEL 2021; 11:bios11080288. [PMID: 34436090 PMCID: PMC8391654 DOI: 10.3390/bios11080288] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 08/18/2021] [Accepted: 08/22/2021] [Indexed: 11/17/2022]
Abstract
Bloodstream infections are a significant cause of morbidity and mortality worldwide. The rapid initiation of effective antibiotic treatment is critical for patients with bloodstream infections. However, the diagnosis of bloodborne pathogens is largely complicated by the matrix effect of blood and the lengthy blood tube culture procedure. Here we report a culture-free workflow for the rapid isolation and enrichment of bacterial pathogens from whole blood for single-cell antimicrobial susceptibility testing (AST). A dextran sedimentation step reduces the concentration of blood cells by 4 orders of magnitude in 20–30 min while maintaining the effective concentration of bacteria in the sample. Red blood cell depletion facilitates the downstream centrifugation-based enrichment step at a sepsis-relevant bacteria concentration. The workflow is compatible with common antibiotic-resistant bacteria and does not influence the minimum inhibitory concentrations. By applying a microfluidic single-cell trapping device, we demonstrate the workflow for the rapid determination of bacterial infection and antimicrobial susceptibility testing at the single-cell level. The entire workflow from blood to categorical AST result can be completed in less than two hours.
Collapse
|
32
|
Culture-Free Detection of Antibiotic Resistance Markers from Native Patient Samples by Hybridization Capture Sequencing. Microorganisms 2021; 9:microorganisms9081672. [PMID: 34442751 PMCID: PMC8398375 DOI: 10.3390/microorganisms9081672] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 07/29/2021] [Accepted: 08/03/2021] [Indexed: 01/04/2023] Open
Abstract
The increasing incidence of antimicrobial resistance (AMR) is a major global challenge. Routine techniques for molecular AMR marker detection are largely based on low-plex PCR and detect dozens to hundreds of AMR markers. To allow for comprehensive and sensitive profiling of AMR markers, we developed a capture-based next generation sequencing (NGS) workflow featuring a novel AMR marker panel based on the curated AMR database ARESdb. Our primary objective was to compare the sensitivity of target enrichment-based AMR marker detection to metagenomics sequencing. Therefore, we determined the limit of detection (LOD) in synovial fluid and urine samples across four key pathogens. We further demonstrated proof-of-concept for AMR marker profiling from septic samples using a selection of urine samples with confirmed monoinfection. The results showed that the capture-based workflow is more sensitive and requires lower sequencing depth compared with metagenomics sequencing, allowing for comprehensive AMR marker detection with an LOD of 1000 CFU/mL. Combining the ARESdb AMR panel with 16S rRNA gene sequencing allowed for the culture-free detection of bacterial taxa and AMR markers directly from septic patient samples at an average sensitivity of 99%. Summarizing, the newly developed ARESdb AMR panel may serve as a valuable tool for comprehensive and sensitive AMR marker detection.
Collapse
|
33
|
Armstrong CM, Lee J, Gehring AG, Capobianco JA. Flow-Through Electrochemical Biosensor for the Detection of Listeria monocytogenes Using Oligonucleotides. SENSORS 2021; 21:s21113754. [PMID: 34071528 PMCID: PMC8198859 DOI: 10.3390/s21113754] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 05/18/2021] [Accepted: 05/24/2021] [Indexed: 11/29/2022]
Abstract
Consumption of food contaminated by Listeria monocytogenes can result in Listeriosis, an illness with hospitalization rates of 94% and mortality rates up to 30%. As a result, U.S. regulatory agencies governing food safety retain zero-tolerance policies for L. monocytogenes. However, detection at such low concentrations often requires strategies such as increasing sample size or culture enrichment. A novel flow-through immunoelectrochemical biosensor has been developed for Escherichia coli O157:H7 detection in 1 L volumes without enrichment. The current work further augments this biosensor’s capabilities to (1) include detection of L. monocytogenes and (2) accommodate genetic detection to help overcome limitations based upon antibody availability and address specificity errors in phenotypic assays. Herein, the conjugation scheme for oligo attachment and the conditions necessary for genetic detection are laid forth while results of the present study demonstrate the sensor’s ability to distinguish L. monocytogenes DNA from L. innocua with a limit of detection of ~2 × 104 cells/mL, which agrees with prior studies. Total time for this assay can be constrained to <2.5 h because a timely culture enrichment period is not necessary. Furthermore, the electrochemical detection assay can be performed with hand-held electronics, allowing this platform to be adopted for near-line monitoring systems.
Collapse
|
34
|
Rodriguez-Mateos P, Ngamsom B, Dyer CE, Iles A, Pamme N. Inertial focusing of microparticles, bacteria, and blood in serpentine glass channels. Electrophoresis 2021; 42:2246-2255. [PMID: 34031893 DOI: 10.1002/elps.202100083] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 05/11/2021] [Accepted: 05/18/2021] [Indexed: 11/08/2022]
Abstract
Early detection of pathogenic microorganisms is pivotal to diagnosis and prevention of health and safety crises. Standard methods for pathogen detection often rely on lengthy culturing procedures, confirmed by biochemical assays, leading to >24 h for a diagnosis. The main challenge for pathogen detection is their low concentration within complex matrices. Detection of blood-borne pathogens via techniques such as PCR requires an initial positive blood culture and removal of inhibitory blood components, reducing its potential as a diagnostic tool. Among different label-free microfluidic techniques, inertial focusing on microscale channels holds great promise for automation, parallelization, and passive continuous separation of particles and cells. This work presents inertial microfluidic manipulation of small particles and cells (1-10 μm) in curved serpentine glass channels etched at different depths (deep and shallow designs) that can be exploited for (1) bacteria preconcentration from biological samples and (2) bacteria-blood cell separation. In our shallow device, the ability to focus Escherichia coli into the channel side streams with high recovery (89% at 2.2× preconcentration factor) could be applied for bacteria preconcentration in urine for diagnosis of urinary tract infections. Relying on differential equilibrium positions of red blood cells and E. coli inside the deep device, 97% red blood cells were depleted from 1:50 diluted blood with 54% E. coli recovered at a throughput of 0.7 mL/min. Parallelization of such devices could process relevant volumes of 7 mL whole blood in 10 min, allowing faster sample preparation for downstream molecular diagnostics of bacteria present in bloodstream.
Collapse
Affiliation(s)
| | - Bongkot Ngamsom
- Department of Chemistry and Biochemistry, University of Hull, Hull, UK
| | | | - Alexander Iles
- Department of Chemistry and Biochemistry, University of Hull, Hull, UK
| | - Nicole Pamme
- Department of Chemistry and Biochemistry, University of Hull, Hull, UK
| |
Collapse
|
35
|
Batcho EC, Miller S, Cover TL, McClain MS, Marasco C, Bell CS, Giorgio TD. Inertial-based Fluidic Platform for Rapid Isolation of Blood-borne Pathogens. Mil Med 2021; 186:129-136. [PMID: 33499487 DOI: 10.1093/milmed/usaa442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 08/18/2020] [Accepted: 10/14/2020] [Indexed: 11/14/2022] Open
Abstract
INTRODUCTION Bacterial sepsis is a life-threatening disease and a significant clinical problem caused by host responses to a microbial infection. Sepsis is a leading cause of death worldwide and, importantly, a significant cause of morbidity and mortality in combat settings, placing a considerable burden on military personnel and military health budgets. The current method of treating sepsis is restricted to pathogen identification, which can be prolonged, and antibiotic administration, which is, initially, often suboptimal. The clinical trials that have been performed to evaluate bacterial separation as a sepsis therapy have been unsuccessful, and new approaches are needed to address this unmet clinical need. MATERIALS AND METHODS An inertial-based, scalable spiral microfluidic device has been created to overcome these previous deficiencies through successful separation of infection-causing pathogens from the bloodstream, serving as a proof of principle for future adaptations. Fluorescent imaging of fluorescent microspheres mimicking the sizes of bacteria cells and blood cells as well as fluorescently stained Acinetobacter baumannii were used to visualize flow within the spiral. The particles were imaged when flowing at a constant volumetric rate of 0.2 mL min-1 through the device. The same device was functionalized with colistin and exposed to flowing A. baumannii at 0.2 mL h-1. RESULTS Fluorescent imaging within the channel under a constant volumetric flow rate demonstrated that smaller, bacteria-sized microspheres accumulated along the inner wall of the channel, whereas larger blood cell-sized microspheres accumulated within the center of the channel. Additionally, fluorescently stained A. baumannii displayed accumulation along the channel walls in agreement with calculated performance. Nearly 106 colony-forming units of A. baumannii were extracted with 100% capture efficiency from flowing phosphate-buffered saline at 0.2 mL h-1 in this device; this is at least one order of magnitude more bacteria than present in the blood of a human at the onset of sepsis. CONCLUSIONS This type of bacterial separation device potentially provides an ideal approach for treating soldiers in combat settings. It eliminates the need for immediate pathogen identification and determination of antimicrobial susceptibility, making it suitable for rapid use within low-resource environments. The overall simplicity and durability of this design also supports its broad translational potential to improve military mortality rates and overall patient outcomes.
Collapse
Affiliation(s)
- Erin C Batcho
- Vanderbilt University Department of Biomedical Engineering, Nashville, TN, 37232
| | - Sinead Miller
- Vanderbilt University Department of Biomedical Engineering, Nashville, TN, 37232
| | - Timothy L Cover
- Vanderbilt University Medical Center, Nashville, TN, 37232.,Veterans Affairs Tennessee Valley Healthcare System, Nashville, TN, 37212
| | - Mark S McClain
- Vanderbilt University Medical Center, Nashville, TN, 37232
| | - Christina Marasco
- Vanderbilt University Department of Biomedical Engineering, Nashville, TN, 37232
| | - Charleson S Bell
- Vanderbilt University Department of Biomedical Engineering, Nashville, TN, 37232
| | - Todd D Giorgio
- Vanderbilt University Department of Biomedical Engineering, Nashville, TN, 37232
| |
Collapse
|
36
|
Zhang Y, Zhou Y, Yang Y, Pappas D. Microfluidics for sepsis early diagnosis and prognosis: a review of recent methods. Analyst 2021; 146:2110-2125. [PMID: 33751011 DOI: 10.1039/d0an02374d] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Sepsis is a complex disorder of immune system response to infections that can be caused by a wide range of clinical contexts. Traditional methods for sepsis detection include molecular diagnosis, biomarkers either based on protein concentration or cell surface expression, and microbiological cultures. Development of point-of-care (POC) instruments, which can provide high accuracy and consume less time, is in unprecedented demand. Within the past few years, applications of microfluidic systems for sepsis detection have achieved excellent performance. In this review, we discuss the most recent microfluidic applications specifically in sepsis detection, and propose their advantages and disadvantages. We also present a comprehensive review of other traditional and current sepsis diagnosis methods to obtain a general understanding of the present conditions, which can hopefully direct the development of a new sepsis roadmap.
Collapse
Affiliation(s)
- Ye Zhang
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, USA.
| | | | | | | |
Collapse
|
37
|
A simple magnetic-assisted microfluidic method for rapid detection and phenotypic characterization of ultralow concentrations of bacteria. Talanta 2021; 230:122291. [PMID: 33934763 DOI: 10.1016/j.talanta.2021.122291] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Revised: 01/25/2021] [Accepted: 02/07/2021] [Indexed: 01/11/2023]
Abstract
Isolation and enumeration of bacteria at ultralow concentrations and antibiotic resistance profiling are of great importance for early diagnosis and treatment of bacteremia. In this work, we describe a simple, rapid, and versatile magnetic-assisted microfluidic method for rapid bacterial detection. The developed method enables magnetophoretic loading of bead-captured bacteria into the microfluidic chamber under external static and dynamic magnetic fields in 4 min. A shallow microfluidic chamber design that enables the monolayer orientation and transportation of the beads and a glass substrate with a thickness of 0.17 mm was utilized to allow high-resolution fluorescence imaging for quantitative detection. Escherichia coli (E. coli) with green fluorescent protein (GFP)-expressing gene and streptavidin-modified superparamagnetic microbeads were used as model bacteria and capturing beads, respectively. The specificity of the method was validated using Lactobacillus gasseri as a negative control group. The limit of detection and limit of quantification values were determined as 2 CFU/ml and 10 CFU/ml of E. coli, respectively. The magnetic-assisted microfluidic method is a versatile tool for the detection of ultralow concentrations of viable bacteria with the linear range of 5-5000 CFU/ml E. coli in 1 h, and providing growth curves and phenotypic characterization bead-captured E. coli in the following 5 h of incubation. Our results are promising for future rapid and sensitive antibiotic susceptibility testing of ultralow numbers of viable cells.
Collapse
|
38
|
Meena GG, Hanson RL, Wood RL, Brown OT, Stott MA, Robison RA, Pitt WG, Woolley AT, Hawkins AR, Schmidt H. 3× multiplexed detection of antibiotic resistant plasmids with single molecule sensitivity. LAB ON A CHIP 2020; 20:3763-3771. [PMID: 33048071 PMCID: PMC7574402 DOI: 10.1039/d0lc00640h] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Bacterial pathogens resistant to antibiotics have become a serious health threat. Those species which have developed resistance against multiple drugs such as the carbapenems, are more lethal as these are last line therapy antibiotics. Current diagnostic tests for these resistance traits are based on singleplex target amplification techniques which can be time consuming and prone to errors. Here, we demonstrate a chip based optofluidic system with single molecule sensitivity for amplification-free, multiplexed detection of plasmids with genes corresponding to antibiotic resistance, within one hour. Rotating disks and microfluidic chips with functionalized polymer monoliths provided the upstream sample preparation steps to selectively extract these plasmids from blood spiked with E. coli DH5α cells. Waveguide-based spatial multiplexing using a multi-mode interference waveguide on an optofluidic chip was used for parallel detection of three different carbapenem resistance genes. These results point the way towards rapid, amplification-free, multiplex analysis of antibiotic-resistant pathogens.
Collapse
Affiliation(s)
- G G Meena
- School of Engineering, University of California, Santa Cruz, 1156 High Street, Santa Cruz, CA 95064, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
39
|
Cabral AD, Rafiei N, de Araujo ED, Radu TB, Toutah K, Nino D, Murcar-Evans BI, Milstein JN, Kraskouskaya D, Gunning PT. Sensitive Detection of Broad-Spectrum Bacteria with Small-Molecule Fluorescent Excimer Chemosensors. ACS Sens 2020; 5:2753-2762. [PMID: 32803944 DOI: 10.1021/acssensors.9b02490] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Antibiotic resistance is a major problem for world health, triggered by the unnecessary usage of broad-spectrum antibiotics on purportedly infected patients. Current clinical standards require lengthy protocols for the detection of bacterial species in sterile physiological fluids. In this work, a class of small-molecule fluorescent chemosensors termed ProxyPhos was shown to be capable of rapid, sensitive, and facile detection of broad-spectrum bacteria. The sensors act via a turn-on fluorescent excimer mechanism, where close-proximity binding of multiple sensor units amplifies a red shift emission signal. ProxyPhos sensors were able to detect down to 10 CFUs of model strains by flow cytometry assays and showed selectivity over mammalian cells in a bacterial coculture through fluorescence microscopy. The studies reveal that the zinc(II)-chelates cyclen and cyclam are novel and effective binding units for the detection of both Gram-negative and Gram-positive bacterial strains. Mode of action studies revealed that the chemosensors detect Gram-negative and Gram-positive strains with two distinct mechanisms. Preliminary studies applying ProxyPhos sensors to sterile physiological fluids (cerebrospinal fluid) in flow cytometry assays were successful. The results suggest that ProxyPhos sensors can be developed as a rapid, inexpensive, and robust tool for the "yes-no" detection of broad-spectrum bacteria in sterile fluids.
Collapse
Affiliation(s)
- Aaron D. Cabral
- Department of Chemical & Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Road North, Mississauga, Ontario L5L 1C6, Canada
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario M5S 3H6, Canada
| | - Nafiseh Rafiei
- Department of Chemical & Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Road North, Mississauga, Ontario L5L 1C6, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, 164 College Street, Toronto, Ontario M5S 3G9, Canada
| | - Elvin D. de Araujo
- Department of Chemical & Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Road North, Mississauga, Ontario L5L 1C6, Canada
| | - Tudor B. Radu
- Department of Chemical & Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Road North, Mississauga, Ontario L5L 1C6, Canada
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario M5S 3H6, Canada
| | - Krimo Toutah
- Department of Chemical & Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Road North, Mississauga, Ontario L5L 1C6, Canada
| | - Daniel Nino
- Department of Chemical & Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Road North, Mississauga, Ontario L5L 1C6, Canada
- Department of Physics, University of Toronto, 60 St. George Street, Toronto, Ontario M5S 1A7, Canada
| | - Bronte I. Murcar-Evans
- Department of Chemical & Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Road North, Mississauga, Ontario L5L 1C6, Canada
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario M5S 3H6, Canada
| | - Joshua N. Milstein
- Department of Chemical & Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Road North, Mississauga, Ontario L5L 1C6, Canada
- Department of Physics, University of Toronto, 60 St. George Street, Toronto, Ontario M5S 1A7, Canada
| | - Dziyana Kraskouskaya
- Department of Chemical & Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Road North, Mississauga, Ontario L5L 1C6, Canada
| | - Patrick T. Gunning
- Department of Chemical & Physical Sciences, University of Toronto Mississauga, 3359 Mississauga Road North, Mississauga, Ontario L5L 1C6, Canada
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario M5S 3H6, Canada
| |
Collapse
|
40
|
Falconer K, Hammond R, Gillespie SH. Improving the recovery and detection of bloodstream pathogens from blood culture. J Med Microbiol 2020; 69:806-811. [PMID: 32490793 PMCID: PMC7451035 DOI: 10.1099/jmm.0.001209] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Introduction. Bloodstream infections (BSI) are growing in incidence and present a serious health threat. Most patients wait up to 48 h before microbiological cultures can confirm a diagnosis. Low numbers of circulating bacteria in patients with BSI mean we need to develop new methods and optimize current methods to facilitate efficient recovery of bacteria from the bloodstream. This will allow detection of positive blood cultures in a more clinically useful timeframe. Many bacterial blood recovery methods are available and usually include a combination of techniques such as centrifugation, filtration, serum separation or lysis treatment. Here, we evaluate nine different bacteria recovery methods performed directly from blood culture. Aim. We sought to identify a bacterial recovery method that would allow for a cost-effective and efficient recovery of common BSI pathogens directly from blood culture. Methods. Simulated E. coli ATCC 25922 blood culture was used as a model system to evaluate nine different bacteria recovery methods. Each method was assessed on recovery yield, cost, hands-on time, risk of contamination and ease of use. The highest scoring recovery method was further evaluated using simulated blood cultures spiked with seven of the most frequently occurring bloodstream pathogens. The recovery yield was calculated based on c.f.u. count before and after each recovery method. Independent t-tests were performed to determine if the recovery methods evaluated were significantly different based on c.f.u. ml−1 log recovery. Results. All nine methods evaluated successfully recovered E. coli ATCC 25922 from simulated blood cultures although the bacterial yield differed significantly. The MALDI-TOF intact cell method offered the poorest recovery with a mean loss of 2.94±0.37 log c.f.u. ml−1. In contrast, a method developed by Bio-Rad achieved the greatest bacterial yield with a mean bacteria loss of 0.27±0.013 log c.f.u. ml−1. Overall, a low-speed serum-separation method was demonstrated to be the most efficient method in terms of time, cost and recovery efficiency and successfully recovered seven of the most frequent BSI pathogens with a mean bacteria loss of 0.717±0.18 log c.f.u. ml−1. Conclusion. The efficiency of bacterial recovery can vary significantly between different methods and thereby can have a critical impact on downstream analysis. The low-speed serum-separation method offered a simple and effective means of recovering common BSI pathogens from blood culture and will be further investigated for use in the rapid detection of bacteraemia and susceptibility testing in clinical practice.
Collapse
Affiliation(s)
- Kerry Falconer
- School of Medicine, University of St Andrews, St Andrews, UK
| | - Robert Hammond
- School of Medicine, University of St Andrews, St Andrews, UK
| | | |
Collapse
|
41
|
Burklund A, Petryk JD, Hoopes PJ, Zhang JXJ. Microfluidic enrichment of bacteria coupled to contact-free lysis on a magnetic polymer surface for downstream molecular detection. BIOMICROFLUIDICS 2020; 14:034115. [PMID: 32642021 PMCID: PMC7316515 DOI: 10.1063/5.0011908] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 05/28/2020] [Indexed: 05/02/2023]
Abstract
We report on a microsystem that couples high-throughput bacterial immunomagnetic capture to contact-free cell lysis using an alternating current magnetic field (AMF) to enable downstream molecular characterization of bacterial nucleic acids. Traditional methods for cell lysis rely on either dilutive chemical methods, expensive biological reagents, or imprecise physical methods. We present a microchip with a magnetic polymer substrate (Mag-Polymer microchip), which enables highly controlled, on-chip heating of biological targets following exposure to an AMF. First, we present a theoretical framework for the quantitation of power generation for single-domain magnetic nanoparticles embedded in a polymer matrix. Next, we demonstrate successful bacterial DNA recovery by coupling (1) high-throughput, sensitive microfluidic immunomagnetic capture of bacteria to (2) on-chip, contact-free bacterial lysis using an AMF. The bacterial capture efficiency exceeded 76% at 50 ml/h at cell loads as low as ∼10 CFU/ml, and intact DNA was successfully recovered at starting bacterial concentrations as low as ∼1000 CFU/ml. Using the presented methodology, cell lysis becomes non-dilutive, temperature is precisely controlled, and potential contamination risks are eliminated. This workflow and substrate modification could be easily integrated in a range of micro-scale diagnostic systems for infectious disease.
Collapse
Affiliation(s)
- Alison Burklund
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire 03755, USA
| | - James D. Petryk
- Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire 03755, USA
| | | | | |
Collapse
|
42
|
Abafogi AT, Kim J, Lee J, Mohammed MO, van Noort D, Park S. 3D-Printed Modular Microfluidic Device Enabling Preconcentrating Bacteria and Purifying Bacterial DNA in Blood for Improving the Sensitivity of Molecular Diagnostics. SENSORS 2020; 20:s20041202. [PMID: 32098268 PMCID: PMC7070462 DOI: 10.3390/s20041202] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/17/2020] [Revised: 02/19/2020] [Accepted: 02/20/2020] [Indexed: 01/22/2023]
Abstract
Molecular diagnostics for sepsis is still a challenge due to the presence of compounds that interfere with gene amplification and bacteria at concentrations lower than the limit of detection (LOD). Here, we report on the development of a 3D printed modular microfluidic device (3DpmμFD) that preconcentrates bacteria of interest in whole blood and purifies their genomic DNA (gDNA). It is composed of a W-shaped microchannel and a conical microchamber. Bacteria of interest are magnetically captured from blood in the device with antibody conjugated magnetic nanoparticles (Ab-MNPs) at 5 mL/min in the W-shaped microchannel, while purified gDNA of the preconcentrated bacteria is obtained with magnetic silica beads (MSBs) at 2 mL/min in the conical microchamber. The conical microchamber was designed to be connected to the microchannel after the capturing process using a 3D-printed rotary valve to minimize the exposure of the MSBs to interfering compounds in blood. The pretreatment process of spiked blood (2.5 mL) can be effectively completed within about 50 min. With the 3DpmμFD, the LOD for the target microorganism Escherichia coli O157:H7 measured by both polymerase chain reaction (PCR) with electrophoresis and quantitative PCR was 10 colony forming unit (CFU) per mL of whole blood. The results suggest that our method lowers the LOD of molecular diagnostics for pathogens in blood by providing bacterial gDNA at high purity and concentration.
Collapse
Affiliation(s)
- Abdurhaman Teyib Abafogi
- School of Mechanical Engineering, Sungkyunkwan University, Suwon 16419, Korea; (A.T.A.); (J.K.); (J.L.)
| | - Jaewon Kim
- School of Mechanical Engineering, Sungkyunkwan University, Suwon 16419, Korea; (A.T.A.); (J.K.); (J.L.)
| | - Jinyeop Lee
- School of Mechanical Engineering, Sungkyunkwan University, Suwon 16419, Korea; (A.T.A.); (J.K.); (J.L.)
| | - Merem Omer Mohammed
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon 16419, Korea;
| | - Danny van Noort
- Division of Biotechnology, IFM, Linkoping University, 58183 Linkoping, Sweden;
- Chair of Micro Process Engineering and Technology (COMPETE), University of Ljubljana, 1000 Ljubljana, Slovenia
- Centro de Investigación en Bioingeniería -BIO, Universidad de Ingenieria y Tecnologia—UTEC, Barranco 15036, Peru
| | - Sungsu Park
- School of Mechanical Engineering, Sungkyunkwan University, Suwon 16419, Korea; (A.T.A.); (J.K.); (J.L.)
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon 16419, Korea;
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon 16419, Korea
- Correspondence: ; Tel.: +82-31-290-7431; Fax: +82-31-290-5889
| |
Collapse
|
43
|
Wood RL, Jensen T, Wadsworth C, Clement M, Nagpal P, Pitt WG. Analysis of Identification Method for Bacterial Species and Antibiotic Resistance Genes Using Optical Data From DNA Oligomers. Front Microbiol 2020; 11:257. [PMID: 32153541 PMCID: PMC7044133 DOI: 10.3389/fmicb.2020.00257] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Accepted: 02/03/2020] [Indexed: 12/13/2022] Open
Abstract
Bacterial antibiotic resistance is becoming a significant health threat, and rapid identification of antibiotic-resistant bacteria is essential to save lives and reduce the spread of antibiotic resistance. This paper analyzes the ability of machine learning algorithms (MLAs) to process data from a novel spectroscopic diagnostic device to identify antibiotic-resistant genes and bacterial species by comparison to available bacterial DNA sequences. Simulation results show that the algorithms attain from 92% accuracy (for genes) up to 99% accuracy (for species). This novel approach identifies genes and species by optically reading the percentage of A, C, G, T bases in 1000s of short 10-base DNA oligomers instead of relying on conventional DNA sequencing in which the sequence of bases in long oligomers provides genetic information. The identification algorithms are robust in the presence of simulated random genetic mutations and simulated random experimental errors. Thus, these algorithms can be used to identify bacterial species, to reveal antibiotic resistance genes, and to perform other genomic analyses. Some MLAs evaluated here are shown to be better than others at accurate gene identification and avoidance of false negative identification of antibiotic resistance.
Collapse
Affiliation(s)
- Ryan L Wood
- Chemical Engineering, Brigham Young University, Provo, UT, United States
| | - Tanner Jensen
- Computer Science, Brigham Young University, Provo, UT, United States
| | - Cindi Wadsworth
- Computer Science, Brigham Young University, Provo, UT, United States
| | - Mark Clement
- Computer Science, Brigham Young University, Provo, UT, United States
| | - Prashant Nagpal
- Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, United States
| | - William G Pitt
- Chemical Engineering, Brigham Young University, Provo, UT, United States
| |
Collapse
|
44
|
Sande MG, Çaykara T, Silva CJ, Rodrigues LR. New solutions to capture and enrich bacteria from complex samples. Med Microbiol Immunol 2020; 209:335-341. [PMID: 32025887 PMCID: PMC7248023 DOI: 10.1007/s00430-020-00659-1] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Accepted: 01/22/2020] [Indexed: 12/31/2022]
Abstract
Current solutions to diagnose bacterial infections though reliable are often time-consuming, laborious and need a specific laboratory setting. There is an unmet need for bedside accurate diagnosis of infectious diseases with a short turnaround time. Moreover, low-cost diagnostics will greatly benefit regions with poor resources. Immunoassays and molecular techniques have been used to develop highly sensitive diagnosis solutions but retaining many of the abovementioned limitations. The detection of bacteria in a biological sample can be enhanced by a previous step of capture and enrichment. This will ease the following process enabling a more sensitive detection and increasing the possibility of a conclusive identification in the downstream diagnosis. This review explores the latest developments regarding the initial steps of capture and enrichment of bacteria from complex samples with the ultimate goal of designing low cost and reliable diagnostics for bacterial infections. Some solutions use specific ligands tethered to magnetic constructs for separation under magnetic fields, microfluidic platforms and engineered nano-patterned surfaces to trap bacteria. Bulk acoustics, advection and nano-filters comprise some of the most innovative solutions for bacteria enrichment.
Collapse
Affiliation(s)
- Maria G Sande
- CEB-Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057, Braga, Portugal
| | - Tugçe Çaykara
- CEB-Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057, Braga, Portugal
- CENTI-Center for Nanotechnology and Smart Materials, Rua Fernando Mesquita 278, 4760-034, Vila Nova de Famalicão, Portugal
| | - Carla Joana Silva
- CENTI-Center for Nanotechnology and Smart Materials, Rua Fernando Mesquita 278, 4760-034, Vila Nova de Famalicão, Portugal
| | - Ligia R Rodrigues
- CEB-Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057, Braga, Portugal.
| |
Collapse
|
45
|
Hügle M, Behrmann O, Raum M, Hufert FT, Urban GA, Dame G. A lab-on-a-chip for free-flow electrophoretic preconcentration of viruses and gel electrophoretic DNA extraction. Analyst 2020; 145:2554-2561. [DOI: 10.1039/c9an02333j] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
A lab-on-a-chip for FFE preconcentration of viruses and gel electrophoretic DNA extraction: complete preparation of amplifiable DNA from dilute specimens.
Collapse
Affiliation(s)
- Matthias Hügle
- Laboratory for Sensors
- Department of Microsystems Engineering (IMTEK)
- University of Freiburg
- Freiburg
- Germany
| | - Ole Behrmann
- Laboratory for Sensors
- Department of Microsystems Engineering (IMTEK)
- University of Freiburg
- Freiburg
- Germany
| | - Madlen Raum
- Laboratory for Sensors
- Department of Microsystems Engineering (IMTEK)
- University of Freiburg
- Freiburg
- Germany
| | - Frank T. Hufert
- Institute of Microbiology and Virology
- Brandenburg Medical School Theodor Fontane
- Neuruppin
- Germany
| | - Gerald A. Urban
- Laboratory for Sensors
- Department of Microsystems Engineering (IMTEK)
- University of Freiburg
- Freiburg
- Germany
| | - Gregory Dame
- Institute of Microbiology and Virology
- Brandenburg Medical School Theodor Fontane
- Neuruppin
- Germany
| |
Collapse
|
46
|
Zhou J, Papautsky I. Viscoelastic microfluidics: progress and challenges. MICROSYSTEMS & NANOENGINEERING 2020; 6:113. [PMID: 34567720 PMCID: PMC8433399 DOI: 10.1038/s41378-020-00218-x] [Citation(s) in RCA: 84] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Revised: 09/23/2020] [Accepted: 09/24/2020] [Indexed: 05/12/2023]
Abstract
The manipulation of cells and particles suspended in viscoelastic fluids in microchannels has drawn increasing attention, in part due to the ability for single-stream three-dimensional focusing in simple channel geometries. Improvement in the understanding of non-Newtonian effects on particle dynamics has led to expanding exploration of focusing and sorting particles and cells using viscoelastic microfluidics. Multiple factors, such as the driving forces arising from fluid elasticity and inertia, the effect of fluid rheology, the physical properties of particles and cells, and channel geometry, actively interact and compete together to govern the intricate migration behavior of particles and cells in microchannels. Here, we review the viscoelastic fluid physics and the hydrodynamic forces in such flows and identify three pairs of competing forces/effects that collectively govern viscoelastic migration. We discuss migration dynamics, focusing positions, numerical simulations, and recent progress in viscoelastic microfluidic applications as well as the remaining challenges. Finally, we hope that an improved understanding of viscoelastic flows in microfluidics can lead to increased sophistication of microfluidic platforms in clinical diagnostics and biomedical research.
Collapse
Affiliation(s)
- Jian Zhou
- Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607 USA
| | - Ian Papautsky
- Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607 USA
| |
Collapse
|
47
|
Zhou J, Mukherjee P, Gao H, Luan Q, Papautsky I. Label-free microfluidic sorting of microparticles. APL Bioeng 2019; 3:041504. [PMID: 31832577 PMCID: PMC6906121 DOI: 10.1063/1.5120501] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Accepted: 11/21/2019] [Indexed: 12/11/2022] Open
Abstract
Massive growth of the microfluidics field has triggered numerous advances in focusing, separating, ordering, concentrating, and mixing of microparticles. Microfluidic systems capable of performing these functions are rapidly finding applications in industrial, environmental, and biomedical fields. Passive and label-free methods are one of the major categories of such systems that have received enormous attention owing to device operational simplicity and low costs. With new platforms continuously being proposed, our aim here is to provide an updated overview of the state of the art for passive label-free microparticle separation, with emphasis on performance and operational conditions. In addition to the now common separation approaches using Newtonian flows, such as deterministic lateral displacement, pinched flow fractionation, cross-flow filtration, hydrodynamic filtration, and inertial microfluidics, we also discuss separation approaches using non-Newtonian, viscoelastic flow. We then highlight the newly emerging approach based on shear-induced diffusion, which enables direct processing of complex samples such as untreated whole blood. Finally, we hope that an improved understanding of label-free passive sorting approaches can lead to sophisticated and useful platforms toward automation in industrial, environmental, and biomedical fields.
Collapse
Affiliation(s)
- Jian Zhou
- Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois 60607, USA
| | - Prithviraj Mukherjee
- Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois 60607, USA
| | - Hua Gao
- Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois 60607, USA
| | - Qiyue Luan
- Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois 60607, USA
| | - Ian Papautsky
- Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois 60607, USA
| |
Collapse
|
48
|
Pitt WG, Alizadeh M, Blanco R, Hunter AK, Bledsoe CG, McClellan DS, Wood ME, Wood RL, Ravsten TV, Hickey CL, Cameron Beard W, Stepan JR, Carter A, Husseini GA, Robison RA, Welling E, Torgesen RN, Anderson CM. Factors affecting sedimentational separation of bacteria from blood. Biotechnol Prog 2019; 36:e2892. [PMID: 31425635 DOI: 10.1002/btpr.2892] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 06/19/2019] [Accepted: 08/01/2019] [Indexed: 12/18/2022]
Abstract
Rapid diagnosis of blood infections requires fast and efficient separation of bacteria from blood. We have developed spinning hollow disks that separate bacteria from blood cells via the differences in sedimentation velocities of these particles. Factors affecting separation included the spinning speed and duration, and disk size. These factors were varied in dozens of experiments for which the volume of separated plasma, and the concentration of bacteria and red blood cells (RBCs) in separated plasma were measured. Data were correlated by a parameter of characteristic sedimentation length, which is the distance that an idealized RBC would travel during the entire spin. Results show that characteristic sedimentation length of 20 to 25 mm produces an optimal separation and collection of bacteria in plasma. This corresponds to spinning a 12-cm-diameter disk at 3,000 rpm for 13 s. Following the spin, a careful deceleration preserves the separation of cells from plasma and provides a bacterial recovery of about 61 ± 5%.
Collapse
Affiliation(s)
- William G Pitt
- Chemical Engineering Department, Brigham Young University, Provo, Utah
| | - Mahsa Alizadeh
- Chemical Engineering Department, Brigham Young University, Provo, Utah
| | - Rae Blanco
- Chemical Engineering Department, Brigham Young University, Provo, Utah
| | - Alex K Hunter
- Chemical Engineering Department, Brigham Young University, Provo, Utah
| | - Colin G Bledsoe
- Chemical Engineering Department, Brigham Young University, Provo, Utah
| | | | - Madison E Wood
- Department of Microbiology and Molecular Biology, Brigham Young University, Provo, Utah
| | - Ryan L Wood
- Chemical Engineering Department, Brigham Young University, Provo, Utah
| | - Tanner V Ravsten
- Chemical Engineering Department, Brigham Young University, Provo, Utah
| | - Caroline L Hickey
- Chemical Engineering Department, Brigham Young University, Provo, Utah
| | | | - Jacob R Stepan
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah
| | - Alexandra Carter
- Chemical Engineering Department, Brigham Young University, Provo, Utah
| | - Ghaleb A Husseini
- Chemical Engineering Department, American University of Sharjah, Sharjah, United Arab Emirates
| | - Richard A Robison
- Department of Microbiology and Molecular Biology, Brigham Young University, Provo, Utah
| | - Evelyn Welling
- Chemical Engineering Department, Brigham Young University, Provo, Utah
| | | | | |
Collapse
|
49
|
Microfluidics-Based Organism Isolation from Whole Blood: An Emerging Tool for Bloodstream Infection Diagnosis. Ann Biomed Eng 2019; 47:1657-1674. [PMID: 30980291 DOI: 10.1007/s10439-019-02256-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Accepted: 03/27/2019] [Indexed: 12/11/2022]
Abstract
The diagnosis of bloodstream infections presents numerous challenges, in part, due to the low concentration of pathogens present in the peripheral bloodstream. As an alternative to existing time-consuming, culture-based diagnostic methods for organism identification, microfluidic devices have emerged as rapid, high-throughput and integrated platforms for bacterial and fungal enrichment, detection, and characterization. This focused review serves to highlight and compare the emerging microfluidic platforms designed for the isolation of sepsis-causing pathogens from blood and suggest important areas for future research.
Collapse
|
50
|
Volbers D, Stierle VK, Ditzel KJ, Aschauer J, Rädler JO, Opitz M, Paulitschke P. Interference Disturbance Analysis Enables Single-Cell Level Growth and Mobility Characterization for Rapid Antimicrobial Susceptibility Testing. NANO LETTERS 2019; 19:643-651. [PMID: 30525694 DOI: 10.1021/acs.nanolett.8b02815] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
To support the emerging battle against antimicrobial resistance (AMR), detection methods that allow fast and accurate antimicrobial susceptibility testing (AST) are urgently needed. The early identification and application of an appropriate antibiotic treatment leads to lower mortality rates and substantial cost savings and prevents the development of resistant pathogens. In this work, we present a diffraction-based method, which is capable of quantitative bacterial growth, mobility, and susceptibility measurements. The method is based on the temporal analysis of the intensity of a light diffraction peak, which arises due to interference at a periodic pattern of gold nanostructures. The presence of bacteria disturbs the constructive interference, leading to an intensity decrease and thus allows the monitoring of bacterial growth in very low volumes. We demonstrate the direct correlation of the decrease in diffraction peak intensity with bacterial cell number starting from single cells and show the capability for rapid high-throughput AST measurements by determining the minimum inhibitory concentration for three different antimicrobials in less than 2-3 h as well as the susceptibility in less than 30-40 min. Furthermore, bacterial mobility is obtained from short-term fluctuations of the diffraction peak intensity and is shown to decrease by a factor of 3 during bacterial attachment to a surface. This multiparameter detection method allows for rapid AST of planktonic and of biofilm-forming bacterial strains in low volumes and in real-time without the need of high initial cell numbers.
Collapse
Affiliation(s)
- David Volbers
- Faculty of Physics and Center for NanoScience (CeNS) , Ludwig-Maximilians-Universität , Geschwister-Scholl-Platz1 , München D-80539 , Germany
| | - Valentin K Stierle
- Faculty of Physics and Center for NanoScience (CeNS) , Ludwig-Maximilians-Universität , Geschwister-Scholl-Platz1 , München D-80539 , Germany
| | - Konstantin J Ditzel
- Faculty of Physics and Center for NanoScience (CeNS) , Ludwig-Maximilians-Universität , Geschwister-Scholl-Platz1 , München D-80539 , Germany
| | - Julian Aschauer
- Faculty of Physics and Center for NanoScience (CeNS) , Ludwig-Maximilians-Universität , Geschwister-Scholl-Platz1 , München D-80539 , Germany
| | - Joachim O Rädler
- Faculty of Physics and Center for NanoScience (CeNS) , Ludwig-Maximilians-Universität , Geschwister-Scholl-Platz1 , München D-80539 , Germany
| | - Madeleine Opitz
- Faculty of Physics and Center for NanoScience (CeNS) , Ludwig-Maximilians-Universität , Geschwister-Scholl-Platz1 , München D-80539 , Germany
| | - Philipp Paulitschke
- Faculty of Physics and Center for NanoScience (CeNS) , Ludwig-Maximilians-Universität , Geschwister-Scholl-Platz1 , München D-80539 , Germany
| |
Collapse
|