Ariyasingha NM, Chowdhury MRH, Samoilenko A, Salnikov OG, Chukanov NV, Kovtunova LM, Bukhtiyarov VI, Shi Z, Luo K, Tan S, Koptyug IV, Goodson BM, Chekmenev EY. Toward Lung Ventilation Imaging Using Hyperpolarized Diethyl Ether Gas Contrast Agent. Chemistry 2024; 30:e202304071. [PMID: 38381807 PMCID: PMC11065616 DOI: 10.1002/chem.202304071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 02/20/2024] [Accepted: 02/21/2024] [Indexed: 02/23/2024]
Abstract
Hyperpolarized 129Xe gas was FDA-approved as an inhalable contrast agent for magnetic resonance imaging of a wide range of pulmonary diseases in December 2022. Despite the remarkable success in clinical research settings, the widespread clinical translation of HP 129Xe gas faces two critical challenges: the high cost of the relatively low-throughput hyperpolarization equipment and the lack of 129Xe imaging capability on clinical MRI scanners, which have narrow-bandwidth electronics designed only for proton (1H) imaging. To solve this translational grand challenge of gaseous hyperpolarized MRI contrast agents, here we demonstrate the utility of batch-mode production of proton-hyperpolarized diethyl ether gas via heterogeneous pairwise addition of parahydrogen to ethyl vinyl ether. An approximately 0.1-liter bolus of hyperpolarized diethyl ether gas was produced in 1 second and injected in excised rabbit lungs. Lung ventilation imaging was performed using sub-second 2D MRI with up to 2×2 mm2 in-plane resolution using a clinical 0.35 T MRI scanner without any modifications. This feasibility demonstration paves the way for the use of inhalable diethyl ether as a gaseous contrast agent for pulmonary MRI applications using any clinical MRI scanner.
Collapse
Affiliation(s)
- Nuwandi M Ariyasingha
- Department of Chemistry, Karmanos Cancer Institute (KCI), Department of Pediatrics, Wayne State University, Detroit, MI-48202, USA
| | - Md Raduanul H Chowdhury
- Department of Chemistry, Karmanos Cancer Institute (KCI), Department of Pediatrics, Wayne State University, Detroit, MI-48202, USA
| | - Anna Samoilenko
- Department of Chemistry, Karmanos Cancer Institute (KCI), Department of Pediatrics, Wayne State University, Detroit, MI-48202, USA
| | - Oleg G Salnikov
- International Tomography Center SB RAS, 3 A Institutskaya Street, Novosibirsk, 630090, Russia
| | - Nikita V Chukanov
- International Tomography Center SB RAS, 3 A Institutskaya Street, Novosibirsk, 630090, Russia
| | - Larisa M Kovtunova
- International Tomography Center SB RAS, 3 A Institutskaya Street, Novosibirsk, 630090, Russia
- Boreskov Institute of Catalysis SB RAS, 5 Acad. Lavrentiev Pr, Novosibirsk, 630090, Russia
| | - Valerii I Bukhtiyarov
- Boreskov Institute of Catalysis SB RAS, 5 Acad. Lavrentiev Pr, Novosibirsk, 630090, Russia
| | - Zhongjie Shi
- Department of Chemistry, Karmanos Cancer Institute (KCI), Department of Pediatrics, Wayne State University, Detroit, MI-48202, USA
| | - Kehuan Luo
- Department of Chemistry, Karmanos Cancer Institute (KCI), Department of Pediatrics, Wayne State University, Detroit, MI-48202, USA
| | - Sidhartha Tan
- Department of Chemistry, Karmanos Cancer Institute (KCI), Department of Pediatrics, Wayne State University, Detroit, MI-48202, USA
| | - Igor V Koptyug
- International Tomography Center SB RAS, 3 A Institutskaya Street, Novosibirsk, 630090, Russia
| | - Boyd M Goodson
- School of Chemical and Biomolecular Sciences, Southern Illinois University, Carbondale, IL-62901, USA
| | - Eduard Y Chekmenev
- Department of Chemistry, Karmanos Cancer Institute (KCI), Department of Pediatrics, Wayne State University, Detroit, MI-48202, USA
| |
Collapse
|
2
|
Babaeipour R, Ouriadov A, Fox MS. Deep Learning Approaches for Quantifying Ventilation Defects in Hyperpolarized Gas Magnetic Resonance Imaging of the Lung: A Review. Bioengineering (Basel) 2023; 10:1349. [PMID: 38135940 PMCID: PMC10740978 DOI: 10.3390/bioengineering10121349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 11/06/2023] [Accepted: 11/21/2023] [Indexed: 12/24/2023] Open
Abstract
This paper provides an in-depth overview of Deep Neural Networks and their application in the segmentation and analysis of lung Magnetic Resonance Imaging (MRI) scans, specifically focusing on hyperpolarized gas MRI and the quantification of lung ventilation defects. An in-depth understanding of Deep Neural Networks is presented, laying the groundwork for the exploration of their use in hyperpolarized gas MRI and the quantification of lung ventilation defects. Five distinct studies are examined, each leveraging unique deep learning architectures and data augmentation techniques to optimize model performance. These studies encompass a range of approaches, including the use of 3D Convolutional Neural Networks, cascaded U-Net models, Generative Adversarial Networks, and nnU-net for hyperpolarized gas MRI segmentation. The findings highlight the potential of deep learning methods in the segmentation and analysis of lung MRI scans, emphasizing the need for consensus on lung ventilation segmentation methods.
Collapse
Affiliation(s)
- Ramtin Babaeipour
- School of Biomedical Engineering, Faculty of Engineering, The University of Western Ontario, London, ON N6A 3K7, Canada;
| | - Alexei Ouriadov
- School of Biomedical Engineering, Faculty of Engineering, The University of Western Ontario, London, ON N6A 3K7, Canada;
- Department of Physics and Astronomy, The University of Western Ontario, London, ON N6A 3K7, Canada;
- Lawson Health Research Institute, London, ON N6C 2R5, Canada
| | - Matthew S. Fox
- Department of Physics and Astronomy, The University of Western Ontario, London, ON N6A 3K7, Canada;
- Lawson Health Research Institute, London, ON N6C 2R5, Canada
| |
Collapse
|
3
|
Lee S, Lee HY, Park J, Kim H, Park JY. Assessment of Pulmonary Ventilation Using 3D Ventilation Flow-Weighted and Ventilation-Weighted Maps From 3D Ultrashort Echo Time (UTE) MRI. J Magn Reson Imaging 2023. [PMID: 37970646 DOI: 10.1002/jmri.29129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 10/28/2023] [Accepted: 10/30/2023] [Indexed: 11/17/2023] Open
Abstract
BACKGROUND Three-dimensional (3D) ventilation flow-weighted (VFW) maps together with 3D ventilation-weighted (VW) maps may help to better assess pulmonary function. PURPOSE To investigate the use of 3D VFW and VW maps for evaluating pulmonary ventilation function. STUDY TYPE Prospective. POPULATION Two patients (one male, 85 years old; one female, 64 years old) with chronic obstructive pulmonary disease (COPD) and nine healthy subjects (all male; 23-27 years). FIELD STRENGTH/SEQUENCE 3-T, 3D radial UTE imaging. ASSESSMENT 3D VFW and VW maps were calculated from 3D UTE MRI by voxel-wise subtraction of respiratory phase images. Their validation was tested in nine healthy volunteers using slow/deep and fast/shallow breathing conditions. Additional validation was performed by comparison with single photon emission computed tomography (SPECT) ventilation maps of one healthy participant. For comparison, gravity dependence of anterior-posterior regional ventilation was assessed by one-dimensional plot of the mean signal intensity for each coronal slice. Structural similarity index measure was also calculated. Finally, VW maps and VFW maps of two COPD patients were evaluated for emphysema lesions with reference to CT images. STATISTICAL TESTS Wilcoxon sign-rank tests for regional Ventilation and Ventilation flow, analysis of variance, post-hoc t-tests and Bonferroni correction, coefficient of variation, Kullback-Liebler divergence. A P-value <0.05 was considered statistically significant. RESULTS The validation of 3D VFW and VW maps was shown by statistically significant differences in ventilation flow and ventilation between the breathing conditions. Additionally, UTE-MRI and SPECT-based ventilation maps showed gravitational dependence in the anteroposterior direction. When applied to patients with COPD, the use of 3D VFW and VW maps was able to differentiate between two patients with different phenotypes. DATA CONCLUSION The use of 3D VFW and VW maps can provide regional information on ventilation function and potentially contribute to assessment of COPD subtypes and disease progression. EVIDENCE LEVEL 2 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Seokwon Lee
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea
| | - Ho Yun Lee
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
- Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Seoul, Republic of Korea
| | - Jinil Park
- Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea
| | - Hyeonha Kim
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea
- Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea
| | - Jang-Yeon Park
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea
- Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea
| |
Collapse
|
4
|
Perron S, Ouriadov A. Hyperpolarized 129Xe MRI at low field: Current status and future directions. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 348:107387. [PMID: 36731353 DOI: 10.1016/j.jmr.2023.107387] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 12/07/2022] [Accepted: 01/23/2023] [Indexed: 06/18/2023]
Abstract
Magnetic Resonance Imaging (MRI) is dictated by the magnetization of the sample, and is thus a low-sensitivity imaging method. Inhalation of hyperpolarized (HP) noble gases, such as helium-3 and xenon-129, is a non-invasive, radiation-risk free imaging technique permitting high resolution imaging of the lungs and pulmonary functions, such as the lung microstructure, diffusion, perfusion, gas exchange, and dynamic ventilation. Instead of increasing the magnetic field strength, the higher spin polarization achievable from this method results in significantly higher net MR signal independent of tissue/water concentration. Moreover, the significantly longer apparent transverse relaxation time T2* of these HP gases at low magnetic field strengths results in fewer necessary radiofrequency (RF) pulses, permitting larger flip angles; this allows for high-sensitivity imaging of in vivo animal and human lungs at conventionally low (<0.5 T) field strengths and suggests that the low field regime is optimal for pulmonary MRI using hyperpolarized gases. In this review, theory on the common spin-exchange optical-pumping method of hyperpolarization and the field dependence of the MR signal of HP gases are presented, in the context of human lung imaging. The current state-of-the-art is explored, with emphasis on both MRI hardware (low field scanners, RF coils, and polarizers) and image acquisition techniques (pulse sequences) advancements. Common challenges surrounding imaging of HP gases and possible solutions are discussed, and the future of low field hyperpolarized gas MRI is posed as being a clinically-accessible and versatile imaging method, circumventing the siting restrictions of conventional high field scanners and bringing point-of-care pulmonary imaging to global facilities.
Collapse
Affiliation(s)
- Samuel Perron
- Department of Physics and Astronomy, The University of Western Ontario, London, Ontario, Canada.
| | - Alexei Ouriadov
- Department of Physics and Astronomy, The University of Western Ontario, London, Ontario, Canada; Lawson Health Research Institute, London, Ontario, Canada; School of Biomedical Engineering, Faculty of Engineering, The University of Western Ontario, London, Ontario, Canada
| |
Collapse
|
5
|
Hudock MR, Pinezich MR, Mir SM, Chen J, Bacchetta M, Vunjak-Novakovic G, Kim J. Emerging Imaging Modalities for Functional Assessment of Donor Lungs Ex Vivo. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2023; 25:100432. [PMID: 36778755 PMCID: PMC9913406 DOI: 10.1016/j.cobme.2022.100432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The severe shortage of functional donor lungs that can be offered to recipients has been a major challenge in lung transplantation. Innovative ex vivo lung perfusion (EVLP) and tissue engineering methodologies are now being developed to repair damaged donor lungs that are deemed unsuitable for transplantation. To assess the efficacy of donor lung reconditioning methods intended to rehabilitate rejected donor lungs, monitoring of lung function with improved spatiotemporal resolution is needed. Recent developments in live imaging are enabling non-destructive, direct, and longitudinal modalities for assessing local tissue and whole lung functions. In this review, we describe how emerging live imaging modalities can be coupled with lung tissue engineering approaches to promote functional recovery of ex vivo donor lungs.
Collapse
Affiliation(s)
- Maria R. Hudock
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Meghan R. Pinezich
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Seyed Mohammad Mir
- Department of Biomedical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA
| | - Jiawen Chen
- Department of Biomedical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA
| | - Matthew Bacchetta
- Department of Cardiac Surgery, Vanderbilt University, Nashville, TN, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Gordana Vunjak-Novakovic
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
- Department of Medicine, Columbia University, New York, NY, USA
| | - Jinho Kim
- Department of Biomedical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA
| |
Collapse
|
6
|
Relationship between Lung and Brain Injury in COVID-19 Patients: A Hyperpolarized 129Xe-MRI-based 8-Month Follow-Up. Biomedicines 2022; 10:biomedicines10040781. [PMID: 35453531 PMCID: PMC9028000 DOI: 10.3390/biomedicines10040781] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 03/18/2022] [Accepted: 03/22/2022] [Indexed: 02/05/2023] Open
Abstract
Although the lungs are the primary organ involved, increasing evidence supports the neuroinvasive potential of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). This study investigates the potential relationship between coronavirus disease (COVID-19)-related deterioration of brain structure and the degree of damage to lung function. Nine COVID-19 patients were recruited in critical condition from Jin Yin-tan Hospital (Wuhan, China) who had been discharged between 4 February and 27 February 2020. The demographic, clinical, treatment, and laboratory data were extracted from the electronic medical records. All patients underwent chest CT imaging, 129Xe gas lung MRI, and 1H brain MRI. Four of the patients were followed up for 8 months. After nearly 12 months of recovery, we found no significant difference in lung ventilation defect percentage (VDP) between the COVID-19 group and the healthy group (3.8 ± 2.1% versus 3.7 ± 2.2%) using 129Xe MRI, and several lung-function-related parameters—such as gas–blood exchange time (T)—showed improvement (42.2 ms versus 32.5 ms). Combined with 1H brain MRI, we found that the change in gray matter volume (GMV) was strongly related to the degree of pulmonary function recovery—the greater the increase in GMV, the higher degree of pulmonary function damage.
Collapse
|
7
|
Bdaiwi AS, Niedbalski PJ, Hossain MM, Willmering MM, Walkup LL, Wang H, Thomen RP, Ruppert K, Woods JC, Cleveland ZI. Improving hyperpolarized 129 Xe ADC mapping in pediatric and adult lungs with uncertainty propagation. NMR IN BIOMEDICINE 2022; 35:e4639. [PMID: 34729838 PMCID: PMC8828677 DOI: 10.1002/nbm.4639] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Revised: 09/30/2021] [Accepted: 10/01/2021] [Indexed: 06/13/2023]
Abstract
RATIONALE Hyperpolarized (HP) 129 Xe-MRI provides non-invasive methods to quantify lung function and structure, with the 129 Xe apparent diffusion coefficient (ADC) being a well validated measure of alveolar airspace size. However, the experimental factors that impact the precision and accuracy of HP 129 Xe ADC measurements have not been rigorously investigated. Here, we introduce an analytical model to predict the experimental uncertainty of 129 Xe ADC estimates. Additionally, we report ADC dependence on age in healthy pediatric volunteers. METHODS An analytical expression for ADC uncertainty was derived from the Stejskal-Tanner equation and simplified Bloch equations appropriate for HP media. Parameters in the model were maximum b-value (bmax ), number of b-values (Nb ), number of phase encoding lines (Nph ), flip angle and the ADC itself. This model was validated by simulations and phantom experiments, and five fitting methods for calculating ADC were investigated. To examine the lower range for 129 Xe ADC, 32 healthy subjects (age 6-40 years) underwent diffusion-weighted 129 Xe MRI. RESULTS The analytical model provides a lower bound on ADC uncertainty and predicts that decreased signal-to-noise ratio yields increases in relative uncertainty (ϵADC) . As such, experimental parameters that impact non-equilibrium 129 Xe magnetization necessarily impact the resulting ϵADC . The values of diffusion encoding parameters (Nb and bmax ) that minimize ϵADC strongly depend on the underlying ADC value, resulting in a global minimum for ϵADC . Bayesian fitting outperformed other methods (error < 5%) for estimating ADC. The whole-lung mean 129 Xe ADC of healthy subjects increased with age at a rate of 1.75 × 10-4 cm2 /s/yr (p = 0.001). CONCLUSIONS HP 129 Xe diffusion MRI can be improved by minimizing the uncertainty of ADC measurements via uncertainty propagation. Doing so will improve experimental accuracy when measuring lung microstructure in vivo and should allow improved monitoring of regional disease progression and assessment of therapy response in a range of lung diseases.
Collapse
Affiliation(s)
- Abdullah S. Bdaiwi
- Center for Pulmonary Imaging Research, Division of
Pulmonary Medicine, Children’s Hospital Medical Center, Cincinnati, OH
45229
- Department of Biomedical Engineering, University of
Cincinnati, Cincinnati, OH 45221
| | - Peter J. Niedbalski
- Center for Pulmonary Imaging Research, Division of
Pulmonary Medicine, Children’s Hospital Medical Center, Cincinnati, OH
45229
| | - Md M. Hossain
- Division of Biostatistics and Epidemiology, Cincinnati
Children’s Hospital Medical Center, Cincinnati, OH 45229
| | - Matthew M. Willmering
- Center for Pulmonary Imaging Research, Division of
Pulmonary Medicine, Children’s Hospital Medical Center, Cincinnati, OH
45229
| | - Laura L. Walkup
- Center for Pulmonary Imaging Research, Division of
Pulmonary Medicine, Children’s Hospital Medical Center, Cincinnati, OH
45229
- Department of Biomedical Engineering, University of
Cincinnati, Cincinnati, OH 45221
- Department of Pediatrics, University of Cincinnati, Cincinnati, OH 45221
| | - Hui Wang
- Philips Healthcare, Cincinnati, OH, USA
| | - Robert P. Thomen
- Center for Pulmonary Imaging Research, Division of
Pulmonary Medicine, Children’s Hospital Medical Center, Cincinnati, OH
45229
| | - Kai Ruppert
- Center for Pulmonary Imaging Research, Division of
Pulmonary Medicine, Children’s Hospital Medical Center, Cincinnati, OH
45229
| | - Jason C. Woods
- Center for Pulmonary Imaging Research, Division of
Pulmonary Medicine, Children’s Hospital Medical Center, Cincinnati, OH
45229
- Department of Pediatrics, University of Cincinnati, Cincinnati, OH 45221
| | - Zackary I. Cleveland
- Center for Pulmonary Imaging Research, Division of
Pulmonary Medicine, Children’s Hospital Medical Center, Cincinnati, OH
45229
- Department of Biomedical Engineering, University of
Cincinnati, Cincinnati, OH 45221
- Department of Pediatrics, University of Cincinnati, Cincinnati, OH 45221
| |
Collapse
|
8
|
Kooner HK, McIntosh MJ, Desaigoudar V, Rayment JH, Eddy RL, Driehuys B, Parraga G. Pulmonary functional MRI: Detecting the structure-function pathologies that drive asthma symptoms and quality of life. Respirology 2022; 27:114-133. [PMID: 35008127 PMCID: PMC10025897 DOI: 10.1111/resp.14197] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 11/09/2021] [Accepted: 12/12/2021] [Indexed: 12/21/2022]
Abstract
Pulmonary functional MRI (PfMRI) using inhaled hyperpolarized, radiation-free gases (such as 3 He and 129 Xe) provides a way to directly visualize inhaled gas distribution and ventilation defects (or ventilation heterogeneity) in real time with high spatial (~mm3 ) resolution. Both gases enable quantitative measurement of terminal airway morphology, while 129 Xe uniquely enables imaging the transfer of inhaled gas across the alveolar-capillary tissue barrier to the red blood cells. In patients with asthma, PfMRI abnormalities have been shown to reflect airway smooth muscle dysfunction, airway inflammation and remodelling, luminal occlusions and airway pruning. The method is rapid (8-15 s), cost-effective (~$300/scan) and very well tolerated in patients, even in those who are very young or very ill, because unlike computed tomography (CT), positron emission tomography and single-photon emission CT, there is no ionizing radiation and the examination takes only a few seconds. However, PfMRI is not without limitations, which include the requirement of complex image analysis, specialized equipment and additional training and quality control. We provide an overview of the three main applications of hyperpolarized noble gas MRI in asthma research including: (1) inhaled gas distribution or ventilation imaging, (2) alveolar microstructure and finally (3) gas transfer into the alveolar-capillary tissue space and from the tissue barrier into red blood cells in the pulmonary microvasculature. We highlight the evidence that supports a deeper understanding of the mechanisms of asthma worsening over time and the pathologies responsible for symptoms and disease control. We conclude with a summary of approaches that have the potential for integration into clinical workflows and that may be used to guide personalized treatment planning.
Collapse
Affiliation(s)
- Harkiran K Kooner
- Robarts Research Institute, Western University, London, Ontario, Canada
- Department of Medical Biophysics, Western University, London, Ontario, Canada
| | - Marrissa J McIntosh
- Robarts Research Institute, Western University, London, Ontario, Canada
- Department of Medical Biophysics, Western University, London, Ontario, Canada
| | - Vedanth Desaigoudar
- Robarts Research Institute, Western University, London, Ontario, Canada
- Department of Medical Biophysics, Western University, London, Ontario, Canada
| | - Jonathan H Rayment
- Department of Pediatrics, University of British Columbia, Vancouver, British Columbia, Canada
| | - Rachel L Eddy
- Centre of Heart Lung Innovation, Division of Respiratory Medicine, Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | - Bastiaan Driehuys
- Center for In Vivo Microscopy, Duke University Medical Centre, Durham, North Carolina, USA
| | - Grace Parraga
- Robarts Research Institute, Western University, London, Ontario, Canada
- Department of Medical Biophysics, Western University, London, Ontario, Canada
- Division of Respirology, Department of Medicine, Western University, London, Ontario, Canada
- School of Biomedical Engineering, Western University, London, Ontario, Canada
| |
Collapse
|
9
|
Saul P, Mamone S, Glöggler S. Hyperpolarization of 15N in an amino acid derivative. RSC Adv 2022; 12:2282-2286. [PMID: 35425247 PMCID: PMC8979135 DOI: 10.1039/d1ra08808d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Accepted: 01/09/2022] [Indexed: 11/21/2022] Open
Abstract
Hyperpolarization is a nuclear magnetic resonance (NMR) technique which can be used to significantly enhance the signal in NMR experiments. In recent years, the possibility to enhance the NMR signal of heteronuclei by the use of para-hydrogen induced polarization (PHIP) has gained attention, especially in the area of possible applications in magnetic resonance imaging (MRI). Herein we introduce a way to synthesize a fully deuterated, 15N labelled amino acid derivative and the possibility to polarize the 15N by means of hydrogenation with para-hydrogen to a polarization level of 0.18%. The longevity of the polarization with a longitudinal relaxation time of more than a minute can allow for the observation of dynamic processes and metabolic imaging in vivo. In addition, we observe the phenomenon of proton–deuterium exchange with a homogeneous catalyst leading to signal enhanced allyl moeities in the precursor. A perdeuterated, 15N-labeled derivative of the amino acid glycine has been synthesized and polarized by means of para-hydrogen induced polarization (PHIP).![]()
Collapse
Affiliation(s)
- Philip Saul
- Research Group for NMR Signal Enhancement, Max Planck Institute for Biophysical Chemistry Am Fassberg 11 37 077 Göttingen Germany +49 551 3961 108.,Center for Biostructural Imaging of Neurodegeneration Von-Siebold-Straßze 3A 37 075 Göttingen Germany
| | - Salvatore Mamone
- Research Group for NMR Signal Enhancement, Max Planck Institute for Biophysical Chemistry Am Fassberg 11 37 077 Göttingen Germany +49 551 3961 108.,Center for Biostructural Imaging of Neurodegeneration Von-Siebold-Straßze 3A 37 075 Göttingen Germany
| | - Stefan Glöggler
- Research Group for NMR Signal Enhancement, Max Planck Institute for Biophysical Chemistry Am Fassberg 11 37 077 Göttingen Germany +49 551 3961 108.,Center for Biostructural Imaging of Neurodegeneration Von-Siebold-Straßze 3A 37 075 Göttingen Germany
| |
Collapse
|
10
|
Marzban-Rad S, Sattari P, Marzban-Rad M, Azimi G. Cardiopulmonary bypass for resection of pancoast tumor with mediastinal extension and involvement of right bronchial branch: A case report. Ann Med Surg (Lond) 2021; 71:102910. [PMID: 34691445 PMCID: PMC8515239 DOI: 10.1016/j.amsu.2021.102910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 09/30/2021] [Accepted: 10/03/2021] [Indexed: 10/27/2022] Open
Abstract
Introduction and importance: Pneumonectomy is commonly associated with cardiopulmonary complications. Pneumonectomy in Pancoast tumor with mediastinal extension and no metastasis could be successful and efficient. Case presentation Herein, we report a successful pneumonectomy of a 54-year-old man with pancoast tumor along with the involvement of mediastinal space including right hilum of the lung, right bronchial, inferior vena cava vein and pericardium. Clinical discussion Based on the bronchoscopy and biopsy, the complete involvement of right bronchial tree was reported and non-small cell carcinoma was diagnosed in pathology. Conclusion To reduce the complications of the surgery, the cardiopulmonary pump machine was used during the operation.
Collapse
Affiliation(s)
- Saeid Marzban-Rad
- Department of Thoracic Surgery, Imam-Reza Hospital, Aja University of Medical Sciences, Tehran, Iran
| | - Parastesh Sattari
- Institute of Health Education and Research, Chamran Hospital, Tehran, Iran
| | - Maryam Marzban-Rad
- Department of Food Science and Technology, School of Nutrition Science and Food Technology, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Ghasem Azimi
- Department of Internal Medicine, School of Medicine, Shahed University, Tehran, Iran
| |
Collapse
|
11
|
Fiedorowicz M, Wieteska M, Rylewicz K, Kossowski B, Piątkowska-Janko E, Czarnecka AM, Toczylowska B, Bogorodzki P. Hyperpolarized 13C tracers: Technical advancements and perspectives for clinical applications. Biocybern Biomed Eng 2021. [DOI: 10.1016/j.bbe.2021.03.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
12
|
Korchak S, Kaltschnee L, Dervisoglu R, Andreas L, Griesinger C, Glöggler S. Spontaneous Enhancement of Magnetic Resonance Signals Using a RASER. Angew Chem Int Ed Engl 2021; 60:20984-20990. [PMID: 34289241 PMCID: PMC8518078 DOI: 10.1002/anie.202108306] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Indexed: 11/06/2022]
Abstract
Nuclear magnetic resonance is usually drastically limited by its intrinsically low sensitivity: Only a few spins contribute to the overall signal. To overcome this limitation, hyperpolarization methods were developed that increase signals several times beyond the normal/thermally polarized signals. The ideal case would be a universal approach that can signal enhance the complete sample of interest in solution to increase detection sensitivity. Here, we introduce a combination of para-hydrogen enhanced magnetic resonance with the phenomenon of the RASER: Large signals of para-hydrogen enhanced molecules interact with the magnetic resonance coil in a way that the signal is spontaneously converted into an in-phase signal. These molecules directly interact with other compounds via dipolar couplings and enhance their signal. We demonstrate that this is not only possible for solvent molecules but also for an amino acid.
Collapse
Affiliation(s)
- Sergey Korchak
- NMR Signal Enhancement GroupMax Planck Institute for Biophysical ChemistryAm Fassberg 1137077GöttingenGermany
- Center for Biostructural Imaging of Neurodegeneration of UMGVon-Siebold-Str. 3A37075GöttingenGermany
| | - Lukas Kaltschnee
- NMR Signal Enhancement GroupMax Planck Institute for Biophysical ChemistryAm Fassberg 1137077GöttingenGermany
- Center for Biostructural Imaging of Neurodegeneration of UMGVon-Siebold-Str. 3A37075GöttingenGermany
| | - Riza Dervisoglu
- Research Group for Solid State NMRMax Planck Institute for Biophysical ChemistryAm Fassberg 1137077GöttingenGermany
| | - Loren Andreas
- Research Group for Solid State NMRMax Planck Institute for Biophysical ChemistryAm Fassberg 1137077GöttingenGermany
| | - Christian Griesinger
- Department of NMR-based Structural BiologyMax Planck Institute for Biophysical ChemistryAm Fassberg 1137077GöttingenGermany
| | - Stefan Glöggler
- NMR Signal Enhancement GroupMax Planck Institute for Biophysical ChemistryAm Fassberg 1137077GöttingenGermany
- Center for Biostructural Imaging of Neurodegeneration of UMGVon-Siebold-Str. 3A37075GöttingenGermany
| |
Collapse
|
13
|
Korchak S, Kaltschnee L, Dervisoglu R, Andreas L, Griesinger C, Glöggler S. Spontaneous Enhancement of Magnetic Resonance Signals Using a RASER. Angew Chem Int Ed Engl 2021. [DOI: 10.1002/ange.202108306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Sergey Korchak
- NMR Signal Enhancement Group Max Planck Institute for Biophysical Chemistry Am Fassberg 11 37077 Göttingen Germany
- Center for Biostructural Imaging of Neurodegeneration of UMG Von-Siebold-Str. 3A 37075 Göttingen Germany
| | - Lukas Kaltschnee
- NMR Signal Enhancement Group Max Planck Institute for Biophysical Chemistry Am Fassberg 11 37077 Göttingen Germany
- Center for Biostructural Imaging of Neurodegeneration of UMG Von-Siebold-Str. 3A 37075 Göttingen Germany
| | - Riza Dervisoglu
- Research Group for Solid State NMR Max Planck Institute for Biophysical Chemistry Am Fassberg 11 37077 Göttingen Germany
| | - Loren Andreas
- Research Group for Solid State NMR Max Planck Institute for Biophysical Chemistry Am Fassberg 11 37077 Göttingen Germany
| | - Christian Griesinger
- Department of NMR-based Structural Biology Max Planck Institute for Biophysical Chemistry Am Fassberg 11 37077 Göttingen Germany
| | - Stefan Glöggler
- NMR Signal Enhancement Group Max Planck Institute for Biophysical Chemistry Am Fassberg 11 37077 Göttingen Germany
- Center for Biostructural Imaging of Neurodegeneration of UMG Von-Siebold-Str. 3A 37075 Göttingen Germany
| |
Collapse
|
14
|
Lee DY, Lee S, Yim SH. Measurement of a 129Xe transverse relaxation rate without the influence of Rb polarization-induced magnetic gradient. APPLIED OPTICS 2021; 60:7290-7296. [PMID: 34613017 DOI: 10.1364/ao.427613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Accepted: 07/10/2021] [Indexed: 06/13/2023]
Abstract
We demonstrate the measurement of the transverse spin relaxation rate of Xe without the influence of the Rb polarization-induced magnetic field gradient. The optical pumping beam and probe beam turn on and off repeatedly during the measurement to reduce the relaxation originating from the Rb polarization-induced magnetic field gradient. During the absence of the optical pumping beam, the nuclear spin of the noble gas atom does not experience the alkali-polarization-induced magnetic field gradient so that the transverse spin relaxation rate (1/T2) decreases. When the duty cycle reaches zero, the measured transverse relaxation time T2 approaches the longitudinal spin relaxation time T1. Our method helps in roughly estimating the longitudinal spin relaxation time with a single measurement of the free induction decay.
Collapse
|
15
|
Marshall H, Stewart NJ, Chan HF, Rao M, Norquay G, Wild JM. In vivo methods and applications of xenon-129 magnetic resonance. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2021; 122:42-62. [PMID: 33632417 PMCID: PMC7933823 DOI: 10.1016/j.pnmrs.2020.11.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 11/26/2020] [Accepted: 11/29/2020] [Indexed: 05/28/2023]
Abstract
Hyperpolarised gas lung MRI using xenon-129 can provide detailed 3D images of the ventilated lung airspaces, and can be applied to quantify lung microstructure and detailed aspects of lung function such as gas exchange. It is sensitive to functional and structural changes in early lung disease and can be used in longitudinal studies of disease progression and therapy response. The ability of 129Xe to dissolve into the blood stream and its chemical shift sensitivity to its local environment allow monitoring of gas exchange in the lungs, perfusion of the brain and kidneys, and blood oxygenation. This article reviews the methods and applications of in vivo129Xe MR in humans, with a focus on the physics of polarisation by optical pumping, radiofrequency coil and pulse sequence design, and the in vivo applications of 129Xe MRI and MRS to examine lung ventilation, microstructure and gas exchange, blood oxygenation, and perfusion of the brain and kidneys.
Collapse
Affiliation(s)
- Helen Marshall
- POLARIS, Imaging Sciences, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Neil J Stewart
- POLARIS, Imaging Sciences, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Ho-Fung Chan
- POLARIS, Imaging Sciences, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Madhwesha Rao
- POLARIS, Imaging Sciences, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Graham Norquay
- POLARIS, Imaging Sciences, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom
| | - Jim M Wild
- POLARIS, Imaging Sciences, Department of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, United Kingdom.
| |
Collapse
|
16
|
Serša I. Magnetic resonance microscopy of samples with translational symmetry with FOVs smaller than sample size. Sci Rep 2021; 11:541. [PMID: 33436897 PMCID: PMC7804297 DOI: 10.1038/s41598-020-80652-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Accepted: 12/22/2020] [Indexed: 11/09/2022] Open
Abstract
In MRI, usually the Field of View (FOV) has to cover the entire object. If this condition is not fulfilled, an infolding image artifact is observed, which suppresses visualization. In this study it is shown that for samples with translational symmetry, i.e., those consisting of identical objects in periodic unit cells, the FOV can be reduced to match the unit cell which enables imaging of an average object, of which the signal is originated from all unit cells of the sample, with no punishment by a loss in signal-to-noise ratio (SNR). This theoretical prediction was confirmed by experiments on a test sample with a 7 × 7 mm2 unit cell arranged in a 3 × 3 matrix which was scanned by the spin-echo and by single point imaging methods. Effects of experimental imperfections in size and orientation mismatch between FOV and unit cell were studied as well. Finally, this method was demonstrated on a 3D periodic sample of tablets, which yielded well-resolved images of moisture distribution in an average tablet, while single tablet imaging provided no results. The method can be applied for SNR increase in imaging of any objects with inherently low signals provided they can be arranged in a periodic structure.
Collapse
Affiliation(s)
- Igor Serša
- Department of Condensed Matter Physics, Jožef Stefan Institute, Jamova 39, 1000, Ljubljana, Slovenia.
| |
Collapse
|
17
|
Inhaled Gas Magnetic Resonance Imaging: Advances, Applications, Limitations, and New Frontiers. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00013-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
18
|
Topping GJ, Hundshammer C, Nagel L, Grashei M, Aigner M, Skinner JG, Schulte RF, Schilling F. Acquisition strategies for spatially resolved magnetic resonance detection of hyperpolarized nuclei. MAGMA (NEW YORK, N.Y.) 2020; 33:221-256. [PMID: 31811491 PMCID: PMC7109201 DOI: 10.1007/s10334-019-00807-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Revised: 10/08/2019] [Accepted: 11/21/2019] [Indexed: 12/13/2022]
Abstract
Hyperpolarization is an emerging method in magnetic resonance imaging that allows nuclear spin polarization of gases or liquids to be temporarily enhanced by up to five or six orders of magnitude at clinically relevant field strengths and administered at high concentration to a subject at the time of measurement. This transient gain in signal has enabled the non-invasive detection and imaging of gas ventilation and diffusion in the lungs, perfusion in blood vessels and tissues, and metabolic conversion in cells, animals, and patients. The rapid development of this method is based on advances in polarizer technology, the availability of suitable probe isotopes and molecules, improved MRI hardware and pulse sequence development. Acquisition strategies for hyperpolarized nuclei are not yet standardized and are set up individually at most sites depending on the specific requirements of the probe, the object of interest, and the MRI hardware. This review provides a detailed introduction to spatially resolved detection of hyperpolarized nuclei and summarizes novel and previously established acquisition strategies for different key areas of application.
Collapse
Affiliation(s)
- Geoffrey J Topping
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Christian Hundshammer
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Luca Nagel
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Martin Grashei
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Maximilian Aigner
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Jason G Skinner
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | | | - Franz Schilling
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
| |
Collapse
|
19
|
Abstract
Acute respiratory distress syndrome (ARDS) consists of acute hypoxemic respiratory failure characterized by massive and heterogeneously distributed loss of lung aeration caused by diffuse inflammation and edema present in interstitial and alveolar spaces. It is defined by consensus criteria, which include diffuse infiltrates on chest imaging-either plain radiography or computed tomography. This review will summarize how imaging sciences can inform modern respiratory management of ARDS and continue to increase the understanding of the acutely injured lung. This review also describes newer imaging methodologies that are likely to inform future clinical decision-making and potentially improve outcome. For each imaging modality, this review systematically describes the underlying principles, technology involved, measurements obtained, insights gained by the technique, emerging approaches, limitations, and future developments. Finally, integrated approaches are considered whereby multimodal imaging may impact management of ARDS.
Collapse
|
20
|
Jafari P, Yaremko BP, Parraga G, Hoover DA, Sadeghi-Naini A, Samani A. 4DCT Ventilation Map Construction Using Biomechanics-base Image Registration and Enhanced Air Segmentation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:6263-6266. [PMID: 31947274 DOI: 10.1109/embc.2019.8857931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Current lung radiation therapy (RT) treatment planning algorithms used in most centers assume homogeneous lung function. However, co-existing pulmonary dysfunctions present in many non-small cell lung cancer (NSCLC) patients, particularly smokers, cause regional variations in both perfusion and ventilation, leading to inhomogeneous lung function. An adaptive RT treatment planning that deliberately avoids highly functional lung regions can potentially reduce pulmonary toxicity and morbidity. The ventilation component of lung function can be measured using a variety of techniques. Recently, 4DCT ventilation imaging has emerged as a cost-effective and accessible method. Current 4DCT ventilation calculation methods, including the intensity-based and Jacobian models, suffer from inaccurate estimations of air volume distribution and unreliability of intensity-based image registration algorithms. In this study, we propose a novel method that utilizes a biomechanical model-based registration along with an accurate air segmentation algorithm to calculate 4DCT ventilation maps. The results show a successful development of ventilation maps using the proposed method.
Collapse
|
21
|
Riberdy V, Litvack M, Stirrat E, Couch M, Post M, Santyr GE. Hyperpolarized 129 Xe imaging of embryonic stem cell-derived alveolar-like macrophages in rat lungs: proof-of-concept study using superparamagnetic iron oxide nanoparticles. Magn Reson Med 2019; 83:1356-1367. [PMID: 31556154 DOI: 10.1002/mrm.27999] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Revised: 07/18/2019] [Accepted: 08/25/2019] [Indexed: 12/29/2022]
Abstract
PURPOSE To measure regional changes in hyperpolarized 129 Xe MRI signal and apparent transverse relaxation ( T 2 ∗ ) because of instillation of SPION-labeled alveolar-like macrophages (ALMs) in the lungs of rats and compare to histology. METHODS MRI was performed in 6 healthy mechanically ventilated rats before instillation, as well as 5 min and 1 h after instillation of 4 million SPION-labeled ALMs into either the left or right lung. T 2 ∗ maps were calculated from 2D multi-echo data at each time point and changes in T 2 ∗ were measured and compared to control rats receiving 4 million unlabeled ALMs. Histology of the ex vivo lungs was used to compare the regional MRI findings with the locations of the SPION-labeled ALMs. RESULTS Regions of signal loss were observed immediately after instillation of unlabeled and SPION-labeled ALMs and persisted at least 1 h in the case of the SPION-labeled ALMs. This was reflected in the measurements of T 2 ∗ . One hour after the instillation of SPION-labeled ALMs, the T 2 ∗ decreased to 54.0 ± 7.0% of the baseline, compared to a full recovery to baseline after the instillation of unlabeled ALMs. Histology confirmed the co-localization of SPION-labeled ALMs with regions of signal loss and T 2 ∗ decreases for each rat. CONCLUSION Hyperpolarized 129 Xe MRI can detect the presence of SPION-labeled ALMs in the airways 1 h after instillation. This approach is promising for targeting and tracking of stem cells for the treatment of lung disease.
Collapse
Affiliation(s)
- Vlora Riberdy
- Translational Medicine Program, Peter Gilgan Center for Research and Learning, The Hospital for Sick Children, Toronto, Canada.,Department of Medical Biophysics, University of Toronto, Toronto, Canada
| | - Michael Litvack
- Translational Medicine Program, Peter Gilgan Center for Research and Learning, The Hospital for Sick Children, Toronto, Canada
| | - Elaine Stirrat
- Translational Medicine Program, Peter Gilgan Center for Research and Learning, The Hospital for Sick Children, Toronto, Canada
| | - Marcus Couch
- Translational Medicine Program, Peter Gilgan Center for Research and Learning, The Hospital for Sick Children, Toronto, Canada.,Department of Medical Biophysics, University of Toronto, Toronto, Canada
| | - Martin Post
- Translational Medicine Program, Peter Gilgan Center for Research and Learning, The Hospital for Sick Children, Toronto, Canada.,Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, Canada
| | - Giles E Santyr
- Translational Medicine Program, Peter Gilgan Center for Research and Learning, The Hospital for Sick Children, Toronto, Canada.,Department of Medical Biophysics, University of Toronto, Toronto, Canada
| |
Collapse
|
22
|
Richardson PM, Iali W, Roy SS, Rayner PJ, Halse ME, Duckett SB. Rapid 13C NMR hyperpolarization delivered from para-hydrogen enables the low concentration detection and quantification of sugars. Chem Sci 2019; 10:10607-10619. [PMID: 32110347 PMCID: PMC7020793 DOI: 10.1039/c9sc03450a] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Accepted: 09/23/2019] [Indexed: 12/16/2022] Open
Abstract
The monosaccharides glucose and fructose are rapidly detected and quantified by 13C NMR in conjunction with the hyperpolarisation method signal amplification by reversible exchange-relay.
Monosaccharides, such as glucose and fructose, are important to life. In this work we highlight how the rapid delivery of improved 13C detectability for sugars by nuclear magnetic resonance (NMR) can be achieved using the para-hydrogen based NMR hyperpolarization method SABRE-Relay (Signal Amplification by Reversible Exchange-Relay). The significant 13C signal enhancements of 250 at a high field of 9.4 T, and 3100 at a low field of 1 T, enable the detection of trace amounts of these materials as well as the quantification of their tautomeric makeup. Using studies on 13C and 2H isotopically labelled agents we demonstrate how hyperpolarization lifetime (T1) values can be extended, and how singlet states with long lifetimes can be created. The precise quantification of d-glucose-13C6-d7 at the millimolar concentration level is shown to be possible within minutes in conjunction with a linear hyperpolarized response as a function of concentration. In addition to the measurements using labelled materials, low concentration detection is also illustrated for millimolar samples with natural abundance 13C where isomeric form quantification can be achieved with a single transient.
Collapse
Affiliation(s)
- Peter M Richardson
- The Centre for Hyperpolarisation in Magnetic Resonance , Department of Chemistry , University of York , UK .
| | - Wissam Iali
- The Centre for Hyperpolarisation in Magnetic Resonance , Department of Chemistry , University of York , UK .
| | - Soumya S Roy
- The Centre for Hyperpolarisation in Magnetic Resonance , Department of Chemistry , University of York , UK .
| | - Peter J Rayner
- The Centre for Hyperpolarisation in Magnetic Resonance , Department of Chemistry , University of York , UK .
| | - Meghan E Halse
- The Centre for Hyperpolarisation in Magnetic Resonance , Department of Chemistry , University of York , UK .
| | - Simon B Duckett
- The Centre for Hyperpolarisation in Magnetic Resonance , Department of Chemistry , University of York , UK .
| |
Collapse
|
23
|
Jagtap AP, Kaltschnee L, Glöggler S. Hyperpolarization of 15N-pyridinium and 15N-aniline derivatives by using parahydrogen: new opportunities to store nuclear spin polarization in aqueous media. Chem Sci 2019; 10:8577-8582. [PMID: 31803432 PMCID: PMC6839503 DOI: 10.1039/c9sc02970b] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Accepted: 07/30/2019] [Indexed: 01/30/2023] Open
Abstract
We introduce 15N quaternary pyridinium as moiety that can be NMR-signal-enhanced by several orders of magnitudes and allows for long-term storage of the so gained hyperpolarization in water.
Hyperpolarization techniques hold the promise to improve the sensitivity of magnetic resonance imaging (MRI) contrast agents by over 10 000-fold. Among these techniques, para-hydrogen induced polarization (PHIP) allows for generating contrast agents within seconds. Typical hyperpolarized contrast agents are traceable for 2–3 minutes only, thus prolonging tracking-times holds great importance for the development of new ways to diagnose and monitor diseases. Here, we report on the design of perdeuterated 15N-containing molecules with longitudinal relaxation times (T1) of several minutes. T1 is a measure for how long hyperpolarization can be stored. In particular, we introduce two new hyperpolarizable families of compounds that we signal enhanced with para-hydrogen: tert-amine aniline derivatives and a quaternary pyridinium compound with 15N-T1 of about 8 minutes. Especially the latter compound has great potential for applicability since we achieved 15N-polarization up to 8% and the pyridinium motif is contained in a variety of drug molecules and is also used in drug delivery systems.
Collapse
Affiliation(s)
- Anil P Jagtap
- Max-Planck-Institute for Biophysical Chemistry , Am Fassberg 11 , 37077 Göttingen , Germany . .,Center for Biostructural Imaging of Neurodegeneration , Von-Siebold-Str. 3a , 37075 Göttingen , Germany
| | - Lukas Kaltschnee
- Max-Planck-Institute for Biophysical Chemistry , Am Fassberg 11 , 37077 Göttingen , Germany . .,Center for Biostructural Imaging of Neurodegeneration , Von-Siebold-Str. 3a , 37075 Göttingen , Germany
| | - Stefan Glöggler
- Max-Planck-Institute for Biophysical Chemistry , Am Fassberg 11 , 37077 Göttingen , Germany . .,Center for Biostructural Imaging of Neurodegeneration , Von-Siebold-Str. 3a , 37075 Göttingen , Germany
| |
Collapse
|
24
|
Bär S, Oerther T, Weigel M, Müller A, Hucker P, Korvink JG, Ko CW, Wapler MC, Leupold J. On the application of balanced steady-state free precession to MR microscopy. MAGMA (NEW YORK, N.Y.) 2019; 32:437-447. [PMID: 30649708 DOI: 10.1007/s10334-019-00736-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Revised: 11/30/2018] [Accepted: 01/03/2019] [Indexed: 06/09/2023]
Abstract
OBJECTIVE The applicability of the balanced steady-state free precession (bSSFP) sequence to the field of MR microscopy was investigated, since the potentially high SNR makes bSSFP attractive. However, particularly at ultra-high magnetic fields, a number of constraints emerge: the frequency sensitivity of the bSSFP signal, the duty cycle of the imaging gradients, and the intrinsic diffusion attenuation of the steady state due to the imaging gradients. MATERIALS AND METHODS Optimization of the bSSFP sequence was performed on three imaging systems (7 T and 9.4 T) suited for MR microscopy. Since biological samples are often imaged in the very proximity of materials from sample containers/holder or devices such as electrodes, several microscopy phantoms representing such circumstances were fabricated and examined with 3D bSSFP. RESULTS Artifact-free microscopic bSSFP images could be obtained with voxel sizes down to 16 µm × 16 µm × 78 µm and with an SNR gain of 25% over standard gradient echo images. CONCLUSION With appropriate choice of phantom materials, optimization of the flip angle to the diffusion-attenuated steady state and protocols considering duty-cycle limitations, bSSFP can be a valuable tool in MR microscopy.
Collapse
Affiliation(s)
- Sébastien Bär
- Department of Radiology, Medical Physics, Faculty of Medicine, Medical Center - University of Freiburg, Killianstrasse 5a, 79106, Freiburg, Germany.
- BrainLinks-BrainTools Cluster of Excellence, University of Freiburg, Freiburg, Germany.
- Department of Computer Science and Engineering, National Sun Yat-sen University, Kaohsiung, Taiwan.
| | - Thomas Oerther
- Microimaging Applications, Bruker BioSpin GmbH, Rheinstetten, Germany
| | - Matthias Weigel
- Department of Radiology, Division of Radiological Physics, University Hospital Basel, Basel, Switzerland
- Department of Biomedical Engineering, University of Basel, Basel, Switzerland
| | - Angelina Müller
- Department for Microsystems Engineering, University of Freiburg, Freiburg, Germany
| | - Patrick Hucker
- Department of Radiology, Medical Physics, Faculty of Medicine, Medical Center - University of Freiburg, Killianstrasse 5a, 79106, Freiburg, Germany
| | - Jan G Korvink
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Cheng-Wen Ko
- Department of Computer Science and Engineering, National Sun Yat-sen University, Kaohsiung, Taiwan
| | - Matthias C Wapler
- Department for Microsystems Engineering, University of Freiburg, Freiburg, Germany
| | - Jochen Leupold
- Department of Radiology, Medical Physics, Faculty of Medicine, Medical Center - University of Freiburg, Killianstrasse 5a, 79106, Freiburg, Germany
- BrainLinks-BrainTools Cluster of Excellence, University of Freiburg, Freiburg, Germany
| |
Collapse
|
25
|
S. Fox M, V. Ouriadov A. High Resolution 3He Pulmonary MRI. Magn Reson Imaging 2019. [DOI: 10.5772/intechopen.84756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
26
|
Zanette B, Santyr G. Accelerated interleaved spiral-IDEAL imaging of hyperpolarized 129 Xe for parametric gas exchange mapping in humans. Magn Reson Med 2019; 82:1113-1119. [PMID: 30989730 DOI: 10.1002/mrm.27765] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2018] [Revised: 01/22/2019] [Accepted: 03/18/2019] [Indexed: 12/24/2022]
Abstract
PURPOSE To demonstrate the feasibility of mapping gas exchange with single breath-hold hyperpolarized (HP) 129 Xe in humans, acquiring parametric maps of lung physiology. The potential benefit of acceleration using parallel imaging for this application is also explored. METHODS Six healthy volunteers were scanned with a modified spiral-IDEAL sequence to acquire gas exchange-weighted images using a single dose of 129 Xe. These images were fit with the model of xenon exchange (MOXE) on a voxel-wise basis calculating parametric maps of lung physiology, specifically: air-capillary barrier thickness (δ), alveolar septal thickness (d), capillary transit time (tx ), pulmonary hematocrit (HCT), and alveolar surface area-to-volume ratio (SVR). An accelerated version of the sequence was also tested in subset of 4 volunteers and compared to the fully sampled (FS) results. RESULTS Mean image-wide values calculated from MOXE parametric maps derived from FS dissolved 129 Xe spiral-IDEAL images were: δ = 0.89 ± 0.17 μm, d = 7.5 ± 0.5 μm, tx = 1.1 ± 0.2s, HCT = 28.8 ± 2.3%, and SVR = 140 ± 16 cm-1 , in good agreement with previously published values based on whole-lung spectroscopy of healthy human subjects. Parallel imaging sufficiently reduces artifacting in accelerated images, but increases disagreement with MOXE parameters derived from FS data with mean voxel-wise unsigned relative differences of: δ = 39 ± 9%, d = 22 ± 3%, tx = 117 ± 43%, HCT = 11 ± 2%, and SVR = 31 ± 12%. CONCLUSION Dissolved HP 129 Xe spiral-IDEAL imaging for gas exchange mapping is feasible in humans using a single breath-hold. Accelerated gas exchange mapping is also shown to be feasible but requires further improvements to increase quantitative accuracy.
Collapse
Affiliation(s)
- Brandon Zanette
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.,Translational Medicine Program, Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Giles Santyr
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.,Translational Medicine Program, Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, Toronto, Ontario, Canada
| |
Collapse
|
27
|
Gutberlet M, Kaireit TF, Voskrebenzev A, Kern AL, Obert A, Wacker F, Hohlfeld JM, Vogel-Claussen J. Repeatability of Regional Lung Ventilation Quantification Using Fluorinated ( 19F) Gas Magnetic Resonance Imaging. Acad Radiol 2019; 26:395-403. [PMID: 30472224 DOI: 10.1016/j.acra.2018.10.021] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2018] [Revised: 07/03/2018] [Accepted: 10/24/2018] [Indexed: 11/17/2022]
Abstract
RATIONALE AND OBJECTIVES To assess the repeatability of global and regional lung ventilation quantification in both healthy subjects and patients with chronic obstructive pulmonary disease (COPD) using fluorinated (19F) gas washout magnetic resonance (MR) imaging in free breathing. MATERIAL AND METHODS In this prospective institutional review board-approved study, 12 healthy nonsmokers and eight COPD patients were examined with 19F dynamic gas washout MR imaging in free breathing and with lung function testing. Measurements were repeated within 2 weeks. Lung ventilation was quantified using 19F gas washout time. Repeatability was analyzed for the total lung and on a regional basis using the coefficient of variation (COV) and Bland-Altman plots. RESULTS In healthy subjects and COPD patients, a good repeatability was found for lung ventilation quantification using dynamic 19F gas washout MR imaging on a global (COV < 8%) and regional (COV < 15%) level. Gas washout time was significantly increased in the COPD group compared to the healthy subjects. CONCLUSION 19F gas washout MR imaging provides a good repeatability of lung ventilation quantification and appears to be sensitive to early changes of regional lung function alterations such as normal aging.
Collapse
Affiliation(s)
- Marcel Gutberlet
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany
| | - Till F Kaireit
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany
| | - Andreas Voskrebenzev
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany
| | - Agilo L Kern
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany
| | - Arnd Obert
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany
| | - Frank Wacker
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany
| | - Jens M Hohlfeld
- Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany; Clinic of Pneumology, Hannover Medical School, Hannover, Germany; Fraunhofer Institute for Toxicology and Experimental Medicine, Clinical Airway Research, Hannover, Germany
| | - Jens Vogel-Claussen
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover 30625, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), Member of the German Center for Lung Research, Hannover, Germany.
| |
Collapse
|
28
|
Korchak S, Emondts M, Mamone S, Blümich B, Glöggler S. Production of highly concentrated and hyperpolarized metabolites within seconds in high and low magnetic fields. Phys Chem Chem Phys 2019; 21:22849-22856. [DOI: 10.1039/c9cp05227e] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
We introduce two experiments that allow for the rapid production of hyperpolarized metabolites. More than 50% 13C polarization in 50 mM concentrations is achieved. This can be translated to portable low field NMR devices.
Collapse
Affiliation(s)
- Sergey Korchak
- NMR Signal Enhancement Group Max-Planck-Institute for Biophysical Chemistry
- 37077 Göttingen
- Germany
- Center for Biostructural Imaging of Neurodegeneration, Von-Siebold-Straße 3A
- 37075 Göttingen
| | - Meike Emondts
- DWI-Leibniz Institute for Interactive Materials
- D-52056 Aachen
- Germany
- Institut für Technische Chemie und Makromolekulare Chemie
- RWTH-Aachen University
| | - Salvatore Mamone
- NMR Signal Enhancement Group Max-Planck-Institute for Biophysical Chemistry
- 37077 Göttingen
- Germany
- Center for Biostructural Imaging of Neurodegeneration, Von-Siebold-Straße 3A
- 37075 Göttingen
| | - Bernhard Blümich
- Institut für Technische Chemie und Makromolekulare Chemie
- RWTH-Aachen University
- Worringerweg 2
- Germany
| | - Stefan Glöggler
- NMR Signal Enhancement Group Max-Planck-Institute for Biophysical Chemistry
- 37077 Göttingen
- Germany
- Center for Biostructural Imaging of Neurodegeneration, Von-Siebold-Straße 3A
- 37075 Göttingen
| |
Collapse
|
29
|
Jakobsson J, Wollmer P, Löndahl J. Charting the human respiratory tract with airborne nanoparticles: evaluation of the Airspace Dimension Assessment technique. J Appl Physiol (1985) 2018; 125:1832-1840. [DOI: 10.1152/japplphysiol.00410.2018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Airspace Dimension Assessment (AiDA) is a technique to assess lung morphology by measuring lung deposition of inhaled nanoparticles. Nanoparticles deposit in the lungs predominately by diffusion, and average diffusion distances, corresponding to effective airspace radii ( rAiDA), can be inferred from measurements of particle recovery after varied breath holds. Also, particle recovery after a 0-s breath hold ( R0) may hold information about the small conducting airways. This study investigates rAiDA at different volumetric sample depths in the lungs of healthy subjects. Measurements were performed with 50-nm polystyrene nanospheres on 19 healthy subjects aged 17–67 yr. Volumetric sample depths ranged from 200 to 5,000 ml and breath-hold times from 5 to 20 s. At the examined volumetric sample depths, rAiDA values ranged from ~200–600 μm, which correspond to dimensions of the bronchiolar and the gas-exchanging regions of the lungs. R0 decreased with volumetric sample depth and showed more intersubject variation than rAiDA. Correlations were found between the AiDA parameters, anthropometry, and lung function tests, but not between rAiDA and R0. For repeated measurements on 3 subjects over an 18-mo period, rAiDA varied on average within ± 7 μm (± 2.4%). The results indicate that AiDA has potential as an efficient new in vivo technique to assess individual lung properties. The information obtained by such measurements may be of value for lung diagnostics, especially for the distal lungs, which are challenging to examine directly by other means. NEW & NOTEWORTHY This is the first study to measure effective airspace radii ( rAiDA) at volumetric sample depths 200–5,000 ml in healthy subjects by Airspace Dimension Assessment (AiDA). Observed rAiDA were 200–600 μm, which corresponds to airspaces for the bronchiolar and the gas-exchanging regions around airway generation 14–17. rAiDA correlated with lung function tests and anthropometry. Measurements of rAiDA on 3 subjects over 11–18 mo were within ± 7 μm.
Collapse
Affiliation(s)
- Jonas Jakobsson
- Department of Ergonomics and Aerosol Technology, Lund University, Lund, Sweden
| | - Per Wollmer
- Department of Translational Medicine, Lund University, Malmö, Sweden
| | - Jakob Löndahl
- Department of Ergonomics and Aerosol Technology, Lund University, Lund, Sweden
| |
Collapse
|
30
|
Tregidgo HFJ, Crabb MG, Hazel AL, Lionheart WRB. On the Feasibility of Automated Mechanical Ventilation Control Through EIT. IEEE Trans Biomed Eng 2018; 65:2459-2470. [DOI: 10.1109/tbme.2018.2798812] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
31
|
Oakes JM, Mummy D, Poorbahrami K, Zha W, Fain SB. Patient-Specific Computational Simulations of Hyperpolarized 3He MRI Ventilation Defects in Healthy and Asthmatic Subjects. IEEE Trans Biomed Eng 2018; 66:1318-1327. [PMID: 30281426 DOI: 10.1109/tbme.2018.2872845] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Combined, medical imaging data and respiratory computer simulations may facilitate novel insight into pulmonary disease phenotypes, including the structure/function relationships within the airways. This integration may ultimately enable improved classification and treatment of asthma. Severe asthma (15% of asthmatics) is particularly challenging to treat, as these patients do not respond well to inhaled therapeutics. METHODS This study combines medical image data with patient-specific computational models to predict gas distributions and airway mechanics in healthy and asthmatic subjects. We achieve this by integrating segmental volume defect percent (SVDP), measured from hyperpolarized 3He MRI and CT images, to create models of patient-specific gas flow within the conducting airways. Predicted and measured SVDP distributions are achieved when the prescribed resistances are increased systematically. RESULTS Because of differences in airway morphology and regional function, airway resistances and flow structures varied between the asthmatic subjects. Specifically, while mean SVDP was similar between the severe asthmatics (4.30±5.22 versus 3.54±5.98%), one subject exhibited abnormal flow structures, high near wall flow gradients, and enhanced conducting airway resistances (17.3E-3versus 1.1E-3 cmH2O-s/mL) in comparison to the other severe asthmatic subject. CONCLUSION By coupling medical imaging data with computer simulations, we provide detailed insight into pathological flow characteristics and airway mechanics in asthmatics, beyond what could be inferred independently.
Collapse
|
32
|
Couch MJ, Ball IK, Li T, Fox MS, Biman B, Albert MS. 19 F MRI of the Lungs Using Inert Fluorinated Gases: Challenges and New Developments. J Magn Reson Imaging 2018; 49:343-354. [PMID: 30248212 DOI: 10.1002/jmri.26292] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 07/23/2018] [Accepted: 07/26/2018] [Indexed: 12/27/2022] Open
Abstract
Fluorine-19 (19 F) MRI using inhaled inert fluorinated gases is an emerging technique that can provide functional images of the lungs. Inert fluorinated gases are nontoxic, abundant, relatively inexpensive, and the technique can be performed on any MRI scanner with broadband multinuclear imaging capabilities. Pulmonary 19 F MRI has been performed in animals, healthy human volunteers, and in patients with lung disease. In this review, the technical requirements of 19 F MRI are discussed, along with various imaging approaches used to optimize the image quality. Lung imaging is typically performed in humans using a gas mixture containing 79% perfluoropropane (PFP) or sulphur hexafluoride (SF6 ) and 21% oxygen. In lung diseases, such as asthma, chronic obstructive pulmonary disease (COPD), and cystic fibrosis (CF), ventilation defects are apparent in regions that the inhaled gas cannot access. 19 F lung images are typically acquired in a single breath-hold, or in a time-resolved, multiple breath fashion. The former provides measurements of the ventilation defect percent (VDP), while the latter provides measurements of gas replacement (ie, fractional ventilation). Finally, preliminary comparisons with other functional lung imaging techniques are discussed, such as Fourier decomposition MRI and hyperpolarized gas MRI. Overall, functional 19 F lung MRI is expected to complement existing proton-based structural imaging techniques, and the combination of structural and functional lung MRI will provide useful outcome measures in the future management of pulmonary diseases in the clinic. Level of Evidence: 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:343-354.
Collapse
Affiliation(s)
- Marcus J Couch
- Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Iain K Ball
- Philips Electronics Australia, North Ryde, Sydney, Australia
| | - Tao Li
- Department of Chemistry, Lakehead University, Thunder Bay, Ontario, Canada
| | - Matthew S Fox
- Imaging Program, Lawson Health Research Institute, London, Ontario, Canada.,Department of Medical Biophysics, University of Western Ontario, London, Ontario, Canada
| | - Birubi Biman
- Thunder Bay Regional Health Sciences Centre, Thunder Bay, Ontario, Canada.,Northern Ontario School of Medicine, Thunder Bay, Ontario, Canada.,Department of Medicine, McMaster University, Hamilton, Ontario, Canada
| | - Mitchell S Albert
- Department of Chemistry, Lakehead University, Thunder Bay, Ontario, Canada.,Northern Ontario School of Medicine, Thunder Bay, Ontario, Canada.,Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada
| |
Collapse
|
33
|
Korchak S, Mamone S, Glöggler S. Over 50 % 1H and 13C Polarization for Generating Hyperpolarized Metabolites-A para-Hydrogen Approach. ChemistryOpen 2018; 7:672-676. [PMID: 30191091 PMCID: PMC6121117 DOI: 10.1002/open.201800086] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2018] [Indexed: 11/23/2022] Open
Abstract
para‐Hydrogen‐induced polarization (PHIP) is a method to rapidly generate hyperpolarized compounds, enhancing the signal of nuclear magnetic resonance (NMR) experiments by several thousand‐fold. The hyperpolarization of metabolites and their use as contrast agents in vivo is an emerging diagnostic technique. High degrees of polarization and extended polarization lifetime are necessary requirements for the detection of metabolites in vivo. Here, we present pulsed NMR methods for obtaining hyperpolarized magnetization in two metabolites. We demonstrate that the hydrogenation with para‐hydrogen of perdeuterated vinyl acetate allows us to create hyperpolarized ethyl acetate with close to 60 % 1H two‐spin order. With nearly 100 % efficiency, this order can either be transferred to 1H in‐phase magnetization or 13C magnetization of the carbonyl function. Close to 60 % polarization is experimentally verified for both nuclei. Cleavage of the ethyl acetate precursor in a 20 s reaction yields ethanol with approximately 27 % 1H polarization and acetate with around 20 % 13C polarization. This development will open new opportunities to generate metabolic contrast agents in less than one minute.
Collapse
Affiliation(s)
- Sergey Korchak
- NMR Signal Enhancement Group Max-Planck-Institute for Biophysical Chemistry Am Faßberg 11 37077 Göttingen Germany.,Center for Biostructural Imaging of Neurodegeneration Von-Siebold-Straße 3A 37075 Göttingen Germany
| | - Salvatore Mamone
- NMR Signal Enhancement Group Max-Planck-Institute for Biophysical Chemistry Am Faßberg 11 37077 Göttingen Germany.,Center for Biostructural Imaging of Neurodegeneration Von-Siebold-Straße 3A 37075 Göttingen Germany
| | - Stefan Glöggler
- NMR Signal Enhancement Group Max-Planck-Institute for Biophysical Chemistry Am Faßberg 11 37077 Göttingen Germany.,Center for Biostructural Imaging of Neurodegeneration Von-Siebold-Straße 3A 37075 Göttingen Germany
| |
Collapse
|
34
|
Korchak S, Yang S, Mamone S, Glöggler S. Pulsed Magnetic Resonance to Signal-Enhance Metabolites within Seconds by utilizing para-Hydrogen. ChemistryOpen 2018; 7:344-348. [PMID: 29761065 PMCID: PMC5938614 DOI: 10.1002/open.201800024] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Indexed: 01/13/2023] Open
Abstract
Diseases such as Alzheimer's and cancer have been linked to metabolic dysfunctions, and further understanding of metabolic pathways raises hope to develop cures for such diseases. To broaden the knowledge of metabolisms in vitro and in vivo, methods are desirable for direct probing of metabolic function. Here, we are introducing a pulsed nuclear magnetic resonance (NMR) approach to generate hyperpolarized metabolites within seconds, which act as metabolism probes. Hyperpolarization represents a magnetic resonance technique to enhance signals by over 10 000-fold. We accomplished an efficient metabolite hyperpolarization by developing an isotopic labeling strategy for generating precursors containing a favorable nuclear spin system to add para-hydrogen and convert its two-spin longitudinal order into enhanced metabolite signals. The transfer is performed by an invented NMR experiment and 20 000-fold signal enhancements are achieved. Our technique provides a fast way of generating hyperpolarized metabolites by using para-hydrogen directly in a high magnetic field without the need for field cycling.
Collapse
Affiliation(s)
- Sergey Korchak
- NMR Signal Enhancement Group Max-Planck-Institute for Biophysical Chemistry Am Faßberg 11 37077 Göttingen Germany.,Center for Biostructural Imaging of Neurodegeneration of UMG Von-Siebold-Str. 3A 37075 Göttingen Germany
| | - Shengjun Yang
- NMR Signal Enhancement Group Max-Planck-Institute for Biophysical Chemistry Am Faßberg 11 37077 Göttingen Germany.,Center for Biostructural Imaging of Neurodegeneration of UMG Von-Siebold-Str. 3A 37075 Göttingen Germany
| | - Salvatore Mamone
- NMR Signal Enhancement Group Max-Planck-Institute for Biophysical Chemistry Am Faßberg 11 37077 Göttingen Germany.,Center for Biostructural Imaging of Neurodegeneration of UMG Von-Siebold-Str. 3A 37075 Göttingen Germany
| | - Stefan Glöggler
- NMR Signal Enhancement Group Max-Planck-Institute for Biophysical Chemistry Am Faßberg 11 37077 Göttingen Germany.,Center for Biostructural Imaging of Neurodegeneration of UMG Von-Siebold-Str. 3A 37075 Göttingen Germany
| |
Collapse
|
35
|
Grigor’ev GY, Nabiev SS. Production and Applications of Spin-Polarized Isotopes of Noble Gases. RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY B 2018. [DOI: 10.1134/s1990793118030107] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
36
|
Chahal S, Prete BRJ, Wade A, Hane FT, Albert MS. Brain Imaging Using Hyperpolarized 129Xe Magnetic Resonance Imaging. Methods Enzymol 2018; 603:305-320. [PMID: 29673533 DOI: 10.1016/bs.mie.2018.01.027] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/03/2023]
Abstract
Hyperpolarized (HP) 129Xe magnetic resonance imaging (MRI) is a novel iteration of traditional MRI that relies on detecting the spins of 1H. Since 129Xe is a gaseous signal source, it can be used for lung imaging. Additionally, 129Xe dissolves in the blood stream and can therefore be detectable in the brain parenchyma and vasculature. In this work, we provide detailed information on the protocols that we have developed to image 129Xe within the brains of both rodents and human subjects.
Collapse
Affiliation(s)
| | | | - Alanna Wade
- Lakehead University, Thunder Bay, ON, Canada
| | - Francis T Hane
- Lakehead University, Thunder Bay, ON, Canada; Thunder Bay Regional Health Research Institute, Thunder Bay, ON, Canada.
| | - Mitchell S Albert
- Lakehead University, Thunder Bay, ON, Canada; Thunder Bay Regional Health Research Institute, Thunder Bay, ON, Canada; Northern Ontario School of Medicine, Thunder Bay, ON, Canada
| |
Collapse
|
37
|
Lizal F, Jedelsky J, Morgan K, Bauer K, Llop J, Cossio U, Kassinos S, Verbanck S, Ruiz-Cabello J, Santos A, Koch E, Schnabel C. Experimental methods for flow and aerosol measurements in human airways and their replicas. Eur J Pharm Sci 2018; 113:95-131. [DOI: 10.1016/j.ejps.2017.08.021] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2017] [Revised: 08/14/2017] [Accepted: 08/17/2017] [Indexed: 12/29/2022]
|
38
|
Kaireit TF, Gutberlet M, Voskrebenzev A, Freise J, Welte T, Hohlfeld JM, Wacker F, Vogel-Claussen J. Comparison of quantitative regional ventilation-weighted fourier decomposition MRI with dynamic fluorinated gas washout MRI and lung function testing in COPD patients. J Magn Reson Imaging 2017; 47:1534-1541. [DOI: 10.1002/jmri.25902] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Accepted: 11/01/2017] [Indexed: 12/23/2022] Open
Affiliation(s)
- Till F. Kaireit
- Department of Diagnostic and Interventional Radiology; Hannover Medical School; Hannover Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), German Center for Lung Research; Hannover Germany
| | - Marcel Gutberlet
- Department of Diagnostic and Interventional Radiology; Hannover Medical School; Hannover Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), German Center for Lung Research; Hannover Germany
| | - Andreas Voskrebenzev
- Department of Diagnostic and Interventional Radiology; Hannover Medical School; Hannover Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), German Center for Lung Research; Hannover Germany
| | - Julia Freise
- Clinic of Pneumology; Hannover Medical School; Hannover Germany
| | - Tobias Welte
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), German Center for Lung Research; Hannover Germany
- Clinic of Pneumology; Hannover Medical School; Hannover Germany
| | - Jens M. Hohlfeld
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), German Center for Lung Research; Hannover Germany
- Clinic of Pneumology; Hannover Medical School; Hannover Germany
- Fraunhofer Institute for Toxicology and Experimental Medicine; Hannover Germany
| | - Frank Wacker
- Department of Diagnostic and Interventional Radiology; Hannover Medical School; Hannover Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), German Center for Lung Research; Hannover Germany
| | - Jens Vogel-Claussen
- Department of Diagnostic and Interventional Radiology; Hannover Medical School; Hannover Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), German Center for Lung Research; Hannover Germany
| |
Collapse
|
39
|
Gutberlet M, Kaireit TF, Voskrebenzev A, Lasch F, Freise J, Welte T, Wacker F, Hohlfeld JM, Vogel-Claussen J. Free-breathing Dynamic 19F Gas MR Imaging for Mapping of Regional Lung Ventilation in Patients with COPD. Radiology 2017; 286:1040-1051. [PMID: 28972817 DOI: 10.1148/radiol.2017170591] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Purpose To quantify regional lung ventilation in patients with chronic obstructive pulmonary disease (COPD) by using free-breathing dynamic fluorinated (fluorine 19 [19F]) gas magnetic resonance (MR) imaging. Materials and Methods In this institutional review board-approved prospective study, 27 patients with COPD were examined by using breath-hold 19F gas wash-in MR imaging during inhalation of a normoxic fluorinated gas mixture (perfluoropropane) and by using free-breathing dynamic 19F gas washout MR imaging after inhalation of the gas mixture was finished for a total of 25-30 L. Regional lung ventilation was quantified by using volume defect percentage (VDP), washout time, number of breaths, and fractional ventilation (FV). To compare different lung function parameters, Pearson correlation coefficient and Fisher z transformation were used, which were corrected for multiple comparisons with the Bonferroni method. Results Statistically significant correlations were observed for all evaluated lung function test parameters compared with median and interquartile range of 19F washout parameters. An inverse linear correlation of median number of breaths (r = -0.82; P < .0001) and median washout times (r = -0.77; P < .0001) with percentage predicted of forced expiratory volume in 1 second (FEV1) was observed; correspondingly median FV (r = 0.86; P < .0001) correlated positively with percentage predicted FEV1. Comparing initial with late phase, median VDP of all subjects decreased from 49% (25th-75th percentile, 35%-62%) to 6% (25th-75th percentile, 2%-10%; P < .0001). VDP at the beginning of the gas wash-in phase (VDPinitial) significantly correlated with percentage predicted FEV1 (r = -0.74; P = .0028) and FV (r = 0.74; P = .0002). Median FV was significantly increased in ventilated regions (11.1% [25th-75th percentile, 6.8%-14.5%]) compared with the defect regions identified by VDPinitial (5.8% [25th-75th percentile, 4.0%-7.4%]; P < .0001). Conclusion Quantification of regional lung ventilation by using dynamic 19F gas washout MR imaging in free breathing is feasible at 1.5 T even in obstructed lung segments. © RSNA, 2017 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Marcel Gutberlet
- From the Institute for Diagnostic and Interventional Radiology (M.G., T.F.K., A.V., F.W., J.V.C.), Institute of Biometry (F.L.), and Clinic of Pneumology (J.F., T.W., J.M.H.), Hannover Medical School, Carl-Neuberg Str 1, 30625 Hannover, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover, the German Center for Lung Research, Hannover, Germany (M.G., T.F.K., A.V., J.F., T.W., F.W., J.M.H., J.V.C.); and Fraunhofer Institute for Toxicology and Experimental Medicine, Clinical Airway Research, Hannover, Germany (J.M.H.)
| | - Till F Kaireit
- From the Institute for Diagnostic and Interventional Radiology (M.G., T.F.K., A.V., F.W., J.V.C.), Institute of Biometry (F.L.), and Clinic of Pneumology (J.F., T.W., J.M.H.), Hannover Medical School, Carl-Neuberg Str 1, 30625 Hannover, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover, the German Center for Lung Research, Hannover, Germany (M.G., T.F.K., A.V., J.F., T.W., F.W., J.M.H., J.V.C.); and Fraunhofer Institute for Toxicology and Experimental Medicine, Clinical Airway Research, Hannover, Germany (J.M.H.)
| | - Andreas Voskrebenzev
- From the Institute for Diagnostic and Interventional Radiology (M.G., T.F.K., A.V., F.W., J.V.C.), Institute of Biometry (F.L.), and Clinic of Pneumology (J.F., T.W., J.M.H.), Hannover Medical School, Carl-Neuberg Str 1, 30625 Hannover, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover, the German Center for Lung Research, Hannover, Germany (M.G., T.F.K., A.V., J.F., T.W., F.W., J.M.H., J.V.C.); and Fraunhofer Institute for Toxicology and Experimental Medicine, Clinical Airway Research, Hannover, Germany (J.M.H.)
| | - Florian Lasch
- From the Institute for Diagnostic and Interventional Radiology (M.G., T.F.K., A.V., F.W., J.V.C.), Institute of Biometry (F.L.), and Clinic of Pneumology (J.F., T.W., J.M.H.), Hannover Medical School, Carl-Neuberg Str 1, 30625 Hannover, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover, the German Center for Lung Research, Hannover, Germany (M.G., T.F.K., A.V., J.F., T.W., F.W., J.M.H., J.V.C.); and Fraunhofer Institute for Toxicology and Experimental Medicine, Clinical Airway Research, Hannover, Germany (J.M.H.)
| | - Julia Freise
- From the Institute for Diagnostic and Interventional Radiology (M.G., T.F.K., A.V., F.W., J.V.C.), Institute of Biometry (F.L.), and Clinic of Pneumology (J.F., T.W., J.M.H.), Hannover Medical School, Carl-Neuberg Str 1, 30625 Hannover, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover, the German Center for Lung Research, Hannover, Germany (M.G., T.F.K., A.V., J.F., T.W., F.W., J.M.H., J.V.C.); and Fraunhofer Institute for Toxicology and Experimental Medicine, Clinical Airway Research, Hannover, Germany (J.M.H.)
| | - Tobias Welte
- From the Institute for Diagnostic and Interventional Radiology (M.G., T.F.K., A.V., F.W., J.V.C.), Institute of Biometry (F.L.), and Clinic of Pneumology (J.F., T.W., J.M.H.), Hannover Medical School, Carl-Neuberg Str 1, 30625 Hannover, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover, the German Center for Lung Research, Hannover, Germany (M.G., T.F.K., A.V., J.F., T.W., F.W., J.M.H., J.V.C.); and Fraunhofer Institute for Toxicology and Experimental Medicine, Clinical Airway Research, Hannover, Germany (J.M.H.)
| | - Frank Wacker
- From the Institute for Diagnostic and Interventional Radiology (M.G., T.F.K., A.V., F.W., J.V.C.), Institute of Biometry (F.L.), and Clinic of Pneumology (J.F., T.W., J.M.H.), Hannover Medical School, Carl-Neuberg Str 1, 30625 Hannover, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover, the German Center for Lung Research, Hannover, Germany (M.G., T.F.K., A.V., J.F., T.W., F.W., J.M.H., J.V.C.); and Fraunhofer Institute for Toxicology and Experimental Medicine, Clinical Airway Research, Hannover, Germany (J.M.H.)
| | - Jens M Hohlfeld
- From the Institute for Diagnostic and Interventional Radiology (M.G., T.F.K., A.V., F.W., J.V.C.), Institute of Biometry (F.L.), and Clinic of Pneumology (J.F., T.W., J.M.H.), Hannover Medical School, Carl-Neuberg Str 1, 30625 Hannover, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover, the German Center for Lung Research, Hannover, Germany (M.G., T.F.K., A.V., J.F., T.W., F.W., J.M.H., J.V.C.); and Fraunhofer Institute for Toxicology and Experimental Medicine, Clinical Airway Research, Hannover, Germany (J.M.H.)
| | - Jens Vogel-Claussen
- From the Institute for Diagnostic and Interventional Radiology (M.G., T.F.K., A.V., F.W., J.V.C.), Institute of Biometry (F.L.), and Clinic of Pneumology (J.F., T.W., J.M.H.), Hannover Medical School, Carl-Neuberg Str 1, 30625 Hannover, Germany; Biomedical Research in Endstage and Obstructive Lung Disease Hannover, the German Center for Lung Research, Hannover, Germany (M.G., T.F.K., A.V., J.F., T.W., F.W., J.M.H., J.V.C.); and Fraunhofer Institute for Toxicology and Experimental Medicine, Clinical Airway Research, Hannover, Germany (J.M.H.)
| |
Collapse
|
40
|
Abstract
This article reviews the physics and technology of producing large quantities of highly spin-polarized 3He nuclei using spin-exchange (SEOP) and metastability-exchange (MEOP) optical pumping. Both technical developments and deeper understanding of the physical processes involved have led to substantial improvements in the capabilities of both methods. For SEOP, the use of spectrally narrowed lasers and K-Rb mixtures has substantially increased the achievable polarization and polarizing rate. For MEOP nearly lossless compression allows for rapid production of polarized 3He and operation in high magnetic fields has likewise significantly increased the pressure at which this method can be performed, and revealed new phenomena. Both methods have benefitted from development of storage methods that allow for spin-relaxation times of hundreds of hours, and specialized precision methods for polarimetry. SEOP and MEOP are now widely applied for spin-polarized targets, neutron spin filters, magnetic resonance imaging, and precision measurements.
Collapse
Affiliation(s)
- T. R. Gentile
- National Institute of Standards and Technology (NIST), Gaithersburg, Maryland 20899, USA
| | - P. J. Nacher
- Laboratoire Kastler Brossel, ENS-PSL Research University, CNRS, UPMC-Sorbonne Universités, Collège de France, Paris, France
| | - B. Saam
- Department of Physics and Astronomy, University of Utah, Salt Lake City, Utah 84112, USA
| | - T. G. Walker
- Department of Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| |
Collapse
|
41
|
Wang K, Pan T, Yang H, Ruan W, Zhong J, Wu G, Zhou X. Assessment of pulmonary microstructural changes by hyperpolarized 129Xe diffusion-weighted imaging in an elastase-instilled rat model of emphysema. J Thorac Dis 2017; 9:2572-2578. [PMID: 28932564 DOI: 10.21037/jtd.2017.08.39] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
BACKGROUND The purpose of this study was to explore the feasibility of hyperpolarized 129Xe diffusion-weighted imaging (DWI) for the evaluation of pulmonary microstructural changes in the presence of pancreatic porcine elastase (PPE)-induced pulmonary emphysema rat model. METHODS Sixteen male Sprague-Dawley (SD) rats were randomly divided into two groups, the emphysema model group and control group. Experimental emphysematous models were made by instilling elastase into rat lungs of model group, the control group were instilled with isodose saline. Hyperpolarized 129Xe magnetic resonance imaging (MRI) and histology were performed in all 16 rats after 30 days. DWIs were performed on a Bruker 7.0 T micro MRI, and the apparent diffusion coefficients (ADCs) were measured in all rats. Mean linear intercepts (MLIs) of pulmonary alveoli were measured on histology. The statistical analyses were performed about the correlation between the mean ADC of hyperpolarized 129Xe in the whole lung and MLI of pulmonary histology metric. RESULTS The pulmonary emphysematous model was successfully confirmed by the histology and all scans were also successful. The ADC value of 129Xe in the model group (0.0313±0.0005 cm2/s) was significantly increased compared with that of the control group (0.0288±0.0007 cm2/s, P<0.0001). Morphological differences such as MLI of pulmonary alveoli were observed between the two groups, the MLI of pulmonary alveoli in model group significantly increased (91±5 µm) than that of control group (50±3 µm, P<0.0001). Furthermore, the ADCs was moderately correlated with MLIs (r=0.724, P<0.01). CONCLUSIONS These results indicate that 129Xe ADC value can quantitatively reflect the alveolar space enlargement and it is a promising biomarker for the detection of pulmonary emphysema.
Collapse
Affiliation(s)
- Ke Wang
- Department of Radiology, Zhongnan Hospital of Wuhan University, Wuhan 430071, China
| | - Ting Pan
- Department of Radiology, Zhongnan Hospital of Wuhan University, Wuhan 430071, China
| | - Hao Yang
- Department of Radiology, Zhongnan Hospital of Wuhan University, Wuhan 430071, China
| | - Weiwei Ruan
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071, China
| | - Jianping Zhong
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071, China
| | - Guangyao Wu
- Department of Radiology, Zhongnan Hospital of Wuhan University, Wuhan 430071, China
| | - Xin Zhou
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071, China
| |
Collapse
|
42
|
Zanette B, Stirrat E, Jelveh S, Hope A, Santyr G. Detection of regional radiation-induced lung injury using hyperpolarized 129Xe chemical shift imaging in a rat model involving partial lung irradiation: Proof-of-concept demonstration. Adv Radiat Oncol 2017; 2:475-484. [PMID: 29114616 PMCID: PMC5605308 DOI: 10.1016/j.adro.2017.05.005] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Accepted: 05/19/2017] [Indexed: 12/25/2022] Open
Abstract
PURPOSE The purpose of this work was to use magnetic resonance imaging (MRI) of hyperpolarized (HP) 129Xe dissolved in pulmonary tissue (PT) and red blood cells (RBCs) to detect regional changes to PT structure and perfusion in a partial-lung rat model of radiation-induced lung injury and compare with histology. METHODS AND MATERIALS The right medial region of the lungs of 6 Sprague-Dawley rats was irradiated (20 Gy, single-fraction). A second nonirradiated cohort served as the control group. Imaging was performed 4 weeks after irradiation to quantify intensity and heterogeneity of PT and RBC 129Xe signals. Imaging findings were correlated with measures of PT and RBC distribution. RESULTS Asymmetric (right vs left) changes in 129Xe signal intensity and heterogeneity were observed in the irradiated cohort but were not seen in the control group. PT signal was observed to increase in intensity and heterogeneity and RBC signal was observed to increase in heterogeneity in the irradiated right lungs, consistent with histology. CONCLUSION Regional changes to PT and RBC 129Xe signals are detectable 4 weeks following partial-lung irradiation in rats.
Collapse
Affiliation(s)
- Brandon Zanette
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario
- Physiology & Experimental Medicine Program, Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, Toronto, Ontario
| | - Elaine Stirrat
- Physiology & Experimental Medicine Program, Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, Toronto, Ontario
| | - Salomeh Jelveh
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario
| | - Andrew Hope
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario
| | - Giles Santyr
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario
- Physiology & Experimental Medicine Program, Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, Toronto, Ontario
| |
Collapse
|
43
|
Guo F, Svenningsen S, Kirby M, Capaldi DP, Sheikh K, Fenster A, Parraga G. Thoracic CT-MRI coregistration for regional pulmonary structure-function measurements of obstructive lung disease. Med Phys 2017; 44:1718-1733. [PMID: 28206676 DOI: 10.1002/mp.12160] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2016] [Revised: 02/06/2017] [Accepted: 02/08/2017] [Indexed: 11/05/2022] Open
Abstract
PURPOSE Recent pulmonary imaging research has revealed that in patients with chronic obstructive pulmonary disease (COPD) and asthma, structural and functional abnormalities are spatially heterogeneous. This novel information may help optimize treatment in individual patients, monitor interventional efficacy, and develop new treatments. Moreover, by automating the measurement of regional biomarkers for the 19 different anatomical lung segments, there is an opportunity to embed imaging biomarkers into clinically acceptable clinical workflows and improve lung disease clinical care. Therefore, to exploit the regional structure-function information provided by thoracic imaging, and as a first step toward this goal, our objective was to develop a fully automated registration pipeline for thoracic x-ray computed tomography (CT) and inhaled gas functional magnetic resonance imaging (MRI) whole lung and segmental structure-function biomarkers. METHODS Thirty-five patients including 15 severe, poorly controlled asthmatics and 20 COPD patients [classified according to the global initiative for chronic obstructive lung disease (GOLD) criteria)] provided written informed consent to a study protocol approved by Health Canada and underwent pulmonary function tests, MRI, and CT during a single 2-hour visit. Using this diverse patient dataset, we developed and evaluated a joint deformable registration approach to simultaneously coregister CT with both 1 H and 3 He MRI by enforcing the similarity of the deformation fields from the two individual registrations. We derived a simpler model that was equivalent to the original challenging optimization problem through variational analysis and the simpler model gave rise to an efficient numerical solver that was parallelized on a graphics processing unit. The coregistered CT-3 He MRI and whole lung/segmental lung masks were used to generate whole lung and segmental 3 He MRI ventilation defect percent (VDP). To estimate fiducial localization reproducibility, a single observer manually identified 109 pairs of CT and 3 He MRI fiducials for 35 patient images on five separate occasions and determined the fiducial localization error (FLE). CT-3 He MRI registration accuracy was evaluated using the target registration error (TRE). Whole lung VDP generated using the algorithm was compared with VDP generated using a previously validated semiautomated approach and computational efficiency was evaluated using run time. RESULTS In 35 patients including 15 with severe asthma and 20 with COPD, mean forced expiratory volume in 1 s (FEV1 ) was 63±24%pred and FEV1 /forced vital capacity (FVC) was 54 ± 17%. FLE was 0.16 mm and 0.34 mm for 3 He MRI and CT, respectively. TRE was 4.5 ± 2.0 mm, 4.0 ± 1.7 mm, 4.8 ± 2.3 mm for asthma, COPD GOLD II, and GOLD III groups, respectively, with a mean of 4.4 ± 2.0 mm for the entire dataset. TRE was significantly improved for joint CT-1 H/3 He MRI registration compared with CT-1 H MRI rigid registration (P < 0.0001). Whole lung VDP generated using the pipeline was not significantly different (P = 0.37) compared to a semiautomated method with which it was strongly correlated (r = 0.93, P < 0.0001). The fully automated pipeline required 11 ± 0.4 min to generate whole lung and segmental VDP. CONCLUSIONS For a diverse group of patients with COPD and asthma, whole lung and segmental VDP was measured using an automated lung image analysis pipeline which provides a way to incorporate lung functional biomarkers into clinical research and patient care.
Collapse
Affiliation(s)
- Fumin Guo
- Robarts Research Institute, The University of Western Ontario, London, Canada.,Graduate Program in Biomedical Engineering, The University of Western Ontario, London, Canada
| | - Sarah Svenningsen
- Robarts Research Institute, The University of Western Ontario, London, Canada
| | - Miranda Kirby
- James Hogg Research Centre, St. Paul's Hospital, University of British Columbia, Vancouver, Canada
| | - Dante Pi Capaldi
- Robarts Research Institute, The University of Western Ontario, London, Canada.,Department of Medical Biophysics, The University of Western Ontario, London, Canada
| | - Khadija Sheikh
- Robarts Research Institute, The University of Western Ontario, London, Canada.,Department of Medical Biophysics, The University of Western Ontario, London, Canada
| | - Aaron Fenster
- Robarts Research Institute, The University of Western Ontario, London, Canada.,Graduate Program in Biomedical Engineering, The University of Western Ontario, London, Canada.,Department of Medical Biophysics, The University of Western Ontario, London, Canada
| | - Grace Parraga
- Robarts Research Institute, The University of Western Ontario, London, Canada.,Graduate Program in Biomedical Engineering, The University of Western Ontario, London, Canada.,Department of Medical Biophysics, The University of Western Ontario, London, Canada
| |
Collapse
|
44
|
Yoshihara L, Roth CJ, Wall WA. Fluid-structure interaction including volumetric coupling with homogenised subdomains for modeling respiratory mechanics. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2017; 33:e2812. [PMID: 27341786 DOI: 10.1002/cnm.2812] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2015] [Revised: 05/13/2016] [Accepted: 06/13/2016] [Indexed: 06/06/2023]
Abstract
In this article, a novel approach is presented for combining standard fluid-structure interaction with additional volumetric constraints to model fluid flow into and from homogenised solid domains. The proposed algorithm is particularly interesting for investigations in the field of respiratory mechanics as it enables the mutual coupling of airflow in the conducting part and local tissue deformation in the respiratory part of the lung by means of a volume constraint. In combination with a classical monolithic fluid-structure interaction approach, a comprehensive model of the human lung can be established that will be useful to gain new insights into respiratory mechanics in health and disease. To illustrate the validity and versatility of the novel approach, three numerical examples including a patient-specific lung model are presented. The proposed algorithm proves its capability of computing clinically relevant airflow distribution and tissue strain data at a level of detail that is not yet achievable, neither with current imaging techniques nor with existing computational models. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Lena Yoshihara
- Institute for Computational Mechanics, Technische Universität München, Boltzmannstrasse 15, D-85748 Garching b. München, Germany
| | - Christian J Roth
- Institute for Computational Mechanics, Technische Universität München, Boltzmannstrasse 15, D-85748 Garching b. München, Germany
| | - Wolfgang A Wall
- Institute for Computational Mechanics, Technische Universität München, Boltzmannstrasse 15, D-85748 Garching b. München, Germany
| |
Collapse
|
45
|
Doganay O, Stirrat E, McKenzie C, Schulte RF, Santyr GE. Quantification of regional early stage gas exchange changes using hyperpolarized (129)Xe MRI in a rat model of radiation-induced lung injury. Med Phys 2017; 43:2410. [PMID: 27147352 DOI: 10.1118/1.4946818] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
PURPOSE To assess the feasibility of hyperpolarized (HP) (129)Xe MRI for detection of early stage radiation-induced lung injury (RILI) in a rat model involving unilateral irradiation by assessing differences in gas exchange dynamics between irradiated and unirradiated lungs. METHODS The dynamics of gas exchange between alveolar air space and pulmonary tissue (PT), PT and red blood cells (RBCs) was measured using single-shot spiral iterative decomposition of water and fat with echo asymmetry and least-squares estimation images of the right and left lungs of two age-matched cohorts of Sprague Dawley rats. The first cohort (n = 5) received 18 Gy irradiation to the right lung using a (60)Co source and the second cohort (n = 5) was not irradiated and served as the healthy control. Both groups were imaged two weeks following irradiation when radiation pneumonitis (RP) was expected to be present. The gas exchange data were fit to a theoretical gas exchange model to extract measurements of pulmonary tissue thickness (LPT) and relative blood volume (VRBC) from each of the right and left lungs of both cohorts. Following imaging, lung specimens were retrieved and percent tissue area (PTA) was assessed histologically to confirm RP and correlate with MRI measurements. RESULTS Statistically significant differences in LPT and VRBC were observed between the irradiated and non-irradiated cohorts. In particular, LPT of the right and left lungs was increased approximately 8.2% and 5.0% respectively in the irradiated cohort. Additionally, VRBC of the right and left lungs was decreased approximately 36.1% and 11.7% respectively for the irradiated cohort compared to the non-irradiated cohort. PTA measurements in both right and left lungs were increased in the irradiated group compared to the non-irradiated cohort for both the left (P < 0.05) and right lungs (P < 0.01) confirming the presence of RP. PTA measurements also correlated with the MRI measurements for both the non-irradiated (r = 0.79, P < 0.01) and irradiated groups (r = 0.91, P < 0.01). CONCLUSIONS Regional RILI can be detected two weeks post-irradiation using HP (129)Xe MRI and analysis of gas exchange curves. This approach correlates well with histology and can potentially be used clinically to assess radiation pneumonitis associated with early RILI to improve radiation therapy outcomes.
Collapse
Affiliation(s)
- Ozkan Doganay
- Department of Medical Biophysics, Western University, London, Ontario N6A5C1, Canada; Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A5C1, Canada; and Department of Oncology, University of Oxford, Old Road Campus Research Building, Roosevelt Drive, Oxford OX3 7DQ, United Kingdom
| | - Elaine Stirrat
- Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, 555 University Avenue, Toronto, Ontario M5G1X8, Canada
| | - Charles McKenzie
- Department of Medical Biophysics, Western University, London, Ontario N6A5C1, Canada and Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A5C1, Canada
| | | | - Giles E Santyr
- Department of Medical Biophysics, Western University, London, Ontario N6A5C1, Canada; Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A5C1, Canada; Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, 555 University Avenue, Toronto, Ontario M5G1X8, Canada; and Department of Medical Biophysics, University of Toronto, Toronto, Ontario M5G1L7, Canada
| |
Collapse
|
46
|
Barskiy DA, Coffey AM, Nikolaou P, Mikhaylov DM, Goodson BM, Branca RT, Lu GJ, Shapiro MG, Telkki VV, Zhivonitko VV, Koptyug IV, Salnikov OG, Kovtunov KV, Bukhtiyarov VI, Rosen MS, Barlow MJ, Safavi S, Hall IP, Schröder L, Chekmenev EY. NMR Hyperpolarization Techniques of Gases. Chemistry 2017; 23:725-751. [PMID: 27711999 PMCID: PMC5462469 DOI: 10.1002/chem.201603884] [Citation(s) in RCA: 109] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2016] [Indexed: 01/09/2023]
Abstract
Nuclear spin polarization can be significantly increased through the process of hyperpolarization, leading to an increase in the sensitivity of nuclear magnetic resonance (NMR) experiments by 4-8 orders of magnitude. Hyperpolarized gases, unlike liquids and solids, can often be readily separated and purified from the compounds used to mediate the hyperpolarization processes. These pure hyperpolarized gases enabled many novel MRI applications including the visualization of void spaces, imaging of lung function, and remote detection. Additionally, hyperpolarized gases can be dissolved in liquids and can be used as sensitive molecular probes and reporters. This Minireview covers the fundamentals of the preparation of hyperpolarized gases and focuses on selected applications of interest to biomedicine and materials science.
Collapse
Affiliation(s)
- Danila A Barskiy
- Department of Radiology, Department of Biomedical Engineering, Department of Physics, Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN, 37232, USA
| | - Aaron M Coffey
- Department of Radiology, Department of Biomedical Engineering, Department of Physics, Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN, 37232, USA
| | - Panayiotis Nikolaou
- Department of Radiology, Department of Biomedical Engineering, Department of Physics, Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN, 37232, USA
| | | | - Boyd M Goodson
- Southern Illinois University, Department of Chemistry and Biochemistry, Materials Technology Center, Carbondale, IL, 62901, USA
| | - Rosa T Branca
- Department of Physics and Astronomy, Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599, USA
| | - George J Lu
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA, 91125, USA
| | - Mikhail G Shapiro
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA, 91125, USA
| | | | - Vladimir V Zhivonitko
- International Tomography Center SB RAS, 630090, Novosibirsk, Russia
- Novosibirsk State University, Pirogova St. 2, 630090, Novosibirsk, Russia
| | - Igor V Koptyug
- International Tomography Center SB RAS, 630090, Novosibirsk, Russia
- Novosibirsk State University, Pirogova St. 2, 630090, Novosibirsk, Russia
| | - Oleg G Salnikov
- International Tomography Center SB RAS, 630090, Novosibirsk, Russia
- Novosibirsk State University, Pirogova St. 2, 630090, Novosibirsk, Russia
| | - Kirill V Kovtunov
- International Tomography Center SB RAS, 630090, Novosibirsk, Russia
- Novosibirsk State University, Pirogova St. 2, 630090, Novosibirsk, Russia
| | - Valerii I Bukhtiyarov
- Boreskov Institute of Catalysis SB RAS, 5 Acad. Lavrentiev Pr., 630090, Novosibirsk, Russia
| | - Matthew S Rosen
- MGH/A.A. Martinos Center for Biomedical Imaging, Boston, MA, 02129, USA
| | - Michael J Barlow
- Respiratory Medicine Department, Queen's Medical Centre, University of Nottingham Medical School, Nottingham, NG7 2UH, UK
| | - Shahideh Safavi
- Respiratory Medicine Department, Queen's Medical Centre, University of Nottingham Medical School, Nottingham, NG7 2UH, UK
| | - Ian P Hall
- Respiratory Medicine Department, Queen's Medical Centre, University of Nottingham Medical School, Nottingham, NG7 2UH, UK
| | - Leif Schröder
- Molecular Imaging, Department of Structural Biology, Leibniz-Institut für Molekulare Pharmakologie (FMP), 13125, Berlin, Germany
| | - Eduard Y Chekmenev
- Department of Radiology, Department of Biomedical Engineering, Department of Physics, Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN, 37232, USA
- Russian Academy of Sciences, 119991, Moscow, Russia
| |
Collapse
|
47
|
Foy BH, Kay D, Bordas R. Modelling responses of the inert-gas washout and MRI to bronchoconstriction. Respir Physiol Neurobiol 2017; 235:8-17. [DOI: 10.1016/j.resp.2016.09.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2016] [Revised: 09/18/2016] [Accepted: 09/20/2016] [Indexed: 10/20/2022]
|
48
|
Ruan W, Zhong J, Guan Y, Xia Y, Zhao X, Han Y, Sun X, Liu S, Ye C, Zhou X. Detection of smoke-induced pulmonary lesions by hyperpolarized129Xe diffusion kurtosis imaging in rat models. Magn Reson Med 2016; 78:1891-1899. [DOI: 10.1002/mrm.26566] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 11/03/2016] [Accepted: 11/09/2016] [Indexed: 12/20/2022]
Affiliation(s)
- Weiwei Ruan
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences; Wuhan P. R. China
- University of Chinese Academy of Sciences; Beijing P. R. China
| | - Jianping Zhong
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences; Wuhan P. R. China
| | - Yu Guan
- Department of Radiology; Changzheng Hospital of the Second Military Medical University; Shanghai China
| | - Yi Xia
- Department of Radiology; Changzheng Hospital of the Second Military Medical University; Shanghai China
| | - Xiuchao Zhao
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences; Wuhan P. R. China
| | - Yeqing Han
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences; Wuhan P. R. China
| | - Xianping Sun
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences; Wuhan P. R. China
- University of Chinese Academy of Sciences; Beijing P. R. China
| | - Shiyuan Liu
- Department of Radiology; Changzheng Hospital of the Second Military Medical University; Shanghai China
| | - Chaohui Ye
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences; Wuhan P. R. China
- University of Chinese Academy of Sciences; Beijing P. R. China
| | - Xin Zhou
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences; Wuhan P. R. China
- University of Chinese Academy of Sciences; Beijing P. R. China
| |
Collapse
|
49
|
Komlosi P, Altes TA, Qing K, Mooney KE, Miller GW, Mata JF, de Lange EE, Tobias WA, Cates GD, Mugler JP. Signal-to-noise ratio, T 2 , and T2* for hyperpolarized helium-3 MRI of the human lung at three magnetic field strengths. Magn Reson Med 2016; 78:1458-1463. [PMID: 27791285 DOI: 10.1002/mrm.26516] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2016] [Revised: 09/07/2016] [Accepted: 09/26/2016] [Indexed: 11/08/2022]
Abstract
PURPOSE To evaluate T2 , T2*, and signal-to-noise ratio (SNR) for hyperpolarized helium-3 (3 He) MRI of the human lung at three magnetic field strengths ranging from 0.43T to 1.5T. METHODS Sixteen healthy volunteers were imaged using a commercial whole body scanner at 0.43T, 0.79T, and 1.5T. Whole-lung T2 values were calculated from a Carr-Purcell-Meiboom-Gill spin-echo-train acquisition. T2* maps and SNR were determined from dual-echo and single-echo gradient-echo images, respectively. Mean whole-lung SNR values were normalized by ventilated lung volume and administered 3 He dose. RESULTS As expected, T2 and T2* values demonstrated a significant inverse relationship to field strength. Hyperpolarized 3 He images acquired at all three field strengths had comparable SNR values and thus appeared visually very similar. Nonetheless, the relatively small SNR differences among field strengths were statistically significant. CONCLUSIONS Hyperpolarized 3 He images of the human lung with similar image quality were obtained at three field strengths ranging from 0.43T and 1.5T. The decrease in susceptibility effects at lower fields that are reflected in longer T2 and T2* values may be advantageous for optimizing pulse sequences inherently sensitive to such effects. The three-fold increase in T2* at lower field strength would allow lower receiver bandwidths, providing a concomitant decrease in noise and relative increase in SNR. Magn Reson Med 78:1458-1463, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Peter Komlosi
- Center for In-vivo Hyperpolarized Gas MR Imaging, Department of Radiology & Medical Imaging, University of Virginia, Charlottesville, Virginia, USA
| | - Talissa A Altes
- Center for In-vivo Hyperpolarized Gas MR Imaging, Department of Radiology & Medical Imaging, University of Virginia, Charlottesville, Virginia, USA
| | - Kun Qing
- Center for In-vivo Hyperpolarized Gas MR Imaging, Department of Radiology & Medical Imaging, University of Virginia, Charlottesville, Virginia, USA
| | - Karen E Mooney
- Department of Physics, University of Virginia, Charlottesville, Virginia, USA
| | - G Wilson Miller
- Center for In-vivo Hyperpolarized Gas MR Imaging, Department of Radiology & Medical Imaging, University of Virginia, Charlottesville, Virginia, USA
| | - Jaime F Mata
- Center for In-vivo Hyperpolarized Gas MR Imaging, Department of Radiology & Medical Imaging, University of Virginia, Charlottesville, Virginia, USA
| | - Eduard E de Lange
- Center for In-vivo Hyperpolarized Gas MR Imaging, Department of Radiology & Medical Imaging, University of Virginia, Charlottesville, Virginia, USA
| | - William A Tobias
- Department of Physics, University of Virginia, Charlottesville, Virginia, USA
| | - Gordon D Cates
- Department of Physics, University of Virginia, Charlottesville, Virginia, USA
| | - John P Mugler
- Center for In-vivo Hyperpolarized Gas MR Imaging, Department of Radiology & Medical Imaging, University of Virginia, Charlottesville, Virginia, USA
| |
Collapse
|
50
|
Abstract
Abstract
Generating parahydrogen-induced polarization (PHIP) of nuclear spins with immobilized transition metal complexes as hydrogenation catalysts allows one to produce pure hyperpolarized substances, which can open new revolutionary perspectives for PHIP applications. A major drawback of immobilized complexes is their low stability under reaction conditions. In the present work we studied an immobilized iridium complex, Ir/SiO2
P, synthesized by a covalent anchoring of Vaska’s complex on phospine-modified silica gel. This complex was used to obtain hyperpolarized gasses in the gas phase hydrogenation of propene, propyne and 1-butyne with parahydrogen in PASADENA and ALTADENA experiments. It was found that, in contrast to other immobilized complexes, Ir/SiO2
P is stable under reaction conditions at up to 140°C, and the reduction of iridium does not occur according to XPS analysis. Moreover, the application of Ir/SiO2
P catalyst allowed us to generate continuous flow of hyperpolarized propene and 1-butene with (300–500)-fold NMR signal enhancement which is significantly higher than commonly observed for most supported metal catalysts. The shape of polarized propene signals in PASADENA experiment has indicated that parahydrogen addition to propyne occurs non-stereospecifically, i.e. PHIP was observed for all protons of the vinyl fragment of propene. The analysis of the polarized signals has shown that syn pairwise addition dominates, which was confirmed by spectra simulations. It was found that storage of Ir/SiO2
P under Ar atmosphere leads to a decrease in PHIP amplitude and an increase in the activity of the catalyst. This observation is discussed in terms of the interaction of Ir/SiO2
P with trace amounts of oxygen in Ar, leading to partial oxidation of triphenylphosphine ligand to triphenylphosphine oxide accompanied by the activation of the immobilized complex. It was also found that the interaction of Ir/SiO2
P with alkenes likely leads to formation of stable monohydride complexes, decreasing the production of PHIP in hydrogenations. At the same time, stable substrate complexes are likely formed in alkyne hydrogenations, leading to a significant decrease in the monohydride complex formation and to an increased production of PHIP.
Collapse
|