Hui SC, Zöllner HJ, Gong T, Hupfeld KE, Gudmundson AT, Murali-Manohar S, Davies-Jenkins CW, Song Y, Chen Y, Oeltzschner G, Wang G, Edden RAE. sLASER and PRESS perform similarly at revealing metabolite-age correlations at 3 T. Magn Reson Med 2024; 91:431-442. [PMID: 37876339 PMCID: PMC10942734 DOI: 10.1002/mrm.29895] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 10/03/2023] [Accepted: 10/04/2023] [Indexed: 10/26/2023]
Abstract
PURPOSE To compare the respective ability of PRESS and sLASER to reveal biological relationships, using age as a validation covariate at 3 T. METHODS MRS data were acquired from 102 healthy volunteers using PRESS and sLASER in centrum semiovale and posterior cingulate cortex (PCC). Acquisition parameters included TR/TE = 2000/30 ms, 96 transients, and 2048 datapoints sampled at 2 kHz. Spectra were analyzed using Osprey. SNR, FWHM linewidth of total creatine, and metabolite concentrations were extracted. A linear model was used to compare SNR and linewidth. Paired t-tests were used to assess differences in metabolite measurements between PRESS and sLASER. Correlations were used to evaluate the relationship between PRESS and sLASER metabolite estimates, as well as the strength of each metabolite-age relationship. Coefficients of variation were calculated to assess inter-subject variability in each metabolite measurement. RESULTS SNR and linewidth were significantly higher (p < 0.01) for sLASER than PRESS in PCC. Paired t-tests showed significant differences between PRESS and sLASER in most metabolite measurements. PRESS-sLASER measurements were significantly correlated (p < 0.05) for most metabolites. Metabolite-age relationships were consistently identified using both methods. Similar coefficients of variation were observed for most metabolites. CONCLUSION The study results suggest strong agreement between PRESS and sLASER in identifying relationships between brain metabolites and age in centrum semiovale and PCC data acquired at 3 T. sLASER is technically desirable due to the reduced chemical shift displacement artifact; however, PRESS performed similarly in homogeneous brain regions at clinical field strength.
Collapse
Affiliation(s)
- Steve C.N. Hui
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
- Developing Brain Institute, Children’s National Hospital, Washington, DC, USA
| | - Helge J. Zöllner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Tao Gong
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Kathleen E. Hupfeld
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Aaron T. Gudmundson
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Saipavitra Murali-Manohar
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Christopher W. Davies-Jenkins
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Yulu Song
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Yufan Chen
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Georg Oeltzschner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Guangbin Wang
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Richard A. E. Edden
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| |
Collapse
|
2
|
Sheikh-Bahaei N, Chen M, Pappas I. Magnetic Resonance Spectroscopy (MRS) in Alzheimer's Disease. Methods Mol Biol 2024; 2785:115-142. [PMID: 38427192 DOI: 10.1007/978-1-0716-3774-6_9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
MRS is a noninvasive technique to measure different metabolites in the brain. Changes in the levels of certain metabolites can be used as surrogate markers for Alzheimer's disease. They can potentially be used for diagnosis, prediction of prognosis, or even assessing response to treatment.There are different techniques for MRS acquisitions including STimulated Echo Acquisition Mode (STEAM) and Point Resolved Spectroscopy (PRESS). In terms of localization, single or multi-voxel methods can be used. Based on current data: 1. NAA, marker of neuronal integrity and viability, reduces in AD with longitudinal changes over the time as the disease progresses. There are data claiming that reduction of NAA is associated with tau accumulation, early neurodegenerative processes, and cognitive decline. Therefore, it can be used as a stage biomarker for AD to assess the severity of the disease. With advancement of disease modifying therapies, there is a potential role for NAA in the future to be used as a marker of response to treatment. 2. mI, marker of glial cell proliferation and activation, is associated with AB pathology and has early changes in the course of the disease. The NAA/mI ratio can be predictive of AD development with high specificity and can be utilized in the clinical setting to stratify cases for further evaluation with PET for potential treatments. 3. The changes in the level of other metabolites such as Chol, Glu, Gln, and GABA are controversial because of the lack of standardization of MRS techniques, current technical limitations, and possible region specific changes. 4. Ultrahigh field MRS and more advanced techniques can overcome many of these limitations and enable us to measure more metabolites with higher accuracy. 5. Standardization of MRS techniques, validation of metabolites' changes against PET using PET-guided technique, and longitudinal follow-ups to investigate the temporal changes of the metabolites in relation to other biomarkers and cognition will be crucial to confirm the utility of MRS as a potential noninvasive biomarker for AD.
Collapse
Affiliation(s)
- Nasim Sheikh-Bahaei
- Department of Radiology, Keck School of Medicine of USC, Los Angeles, CA, USA.
| | - Michelle Chen
- Keck School of Medicine of USC, USC, Los Angeles, CA, USA
| | - Ioannis Pappas
- USC Mark and Mary Stevens Neuroimaging and Informatics Institute, USC, Los Angeles, CA, USA
| |
Collapse
|
3
|
Hui SC, Gong T, Zöllner HJ, Hupfeld KE, Gudmundson AT, Murali-Manohar S, Davies-Jenkins CW, Song Y, Chen Y, Oeltzschner G, Wang G, Edden RAE. sLASER and PRESS Perform Similarly at Revealing Metabolite-Age Correlations. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.01.18.524597. [PMID: 36711794 PMCID: PMC9882274 DOI: 10.1101/2023.01.18.524597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Purpose To compare the respective ability of PRESS and sLASER to reveal biological relationships, using age as a validation covariate. Methods MRS data were acquired from 102 healthy volunteers using PRESS and sLASER in centrum semiovale (CSO) and posterior cingulate cortex (PCC) regions. Acquisition parameters included TR/TE 2000/30 ms; 96 transients; 2048 datapoints sampled at 2 kHz.Spectra were analyzed using Osprey. Signal-to-noise ratio (SNR), full-width-half-maximum linewidth of tCr, and metabolite concentrations were extracted. A linear model was used to compare SNR and linewidth. Paired t-tests were used to assess differences in metabolite measurements between PRESS and sLASER. Correlations were used to evaluate the relationship between PRESS and sLASER metabolite estimates, as well as the strength of each metabolite-age relationship. Coefficients of variation were calculated to assess inter-subject variability in each metabolite measurement. Results SNR and linewidth were significantly higher (p<0.05) for sLASER than PRESS. Paired t-tests showed significant differences between PRESS and sLASER in most metabolite measurements. Metabolite measures were significantly correlated (p<0.05) for most metabolites between the two methods except GABA, Gln and Lac in CSO and GSH, Lac and NAAG in PCC. Metabolite-age relationships were consistently identified using both PRESS and sLASER. Similar CVs were observed for most metabolites. Conclusion The study results suggest strong agreement between PRESS and sLASER in identifying relationships between brain metabolites and age in CSO and PCC data acquired at 3T. sLASER is technically desirable due to the reduced chemical shift displacement artifact; however, PRESS performed similarly in 'good' brain regions at clinical field strength.
Collapse
Affiliation(s)
- Steve C.N. Hui
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Tao Gong
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Helge J. Zöllner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Kathleen E. Hupfeld
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Aaron T. Gudmundson
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Saipavitra Murali-Manohar
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Christopher W. Davies-Jenkins
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Yulu Song
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Yufan Chen
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Georg Oeltzschner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Guangbin Wang
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Richard A. E. Edden
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| |
Collapse
|
4
|
Stamatelatou A, Scheenen TWJ, Heerschap A. Developments in proton MR spectroscopic imaging of prostate cancer. MAGMA (NEW YORK, N.Y.) 2022; 35:645-665. [PMID: 35445307 PMCID: PMC9363347 DOI: 10.1007/s10334-022-01011-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 03/04/2022] [Accepted: 03/22/2022] [Indexed: 10/25/2022]
Abstract
In this paper, we review the developments of 1H-MR spectroscopic imaging (MRSI) methods designed to investigate prostate cancer, covering key aspects such as specific hardware, dedicated pulse sequences for data acquisition and data processing and quantification techniques. Emphasis is given to recent advancements in MRSI methodologies, as well as future developments, which can lead to overcome difficulties associated with commonly employed MRSI approaches applied in clinical routine. This includes the replacement of standard PRESS sequences for volume selection, which we identified as inadequate for clinical applications, by sLASER sequences and implementation of 1H MRSI without water signal suppression. These may enable a new evaluation of the complementary role and significance of MRSI in prostate cancer management.
Collapse
Affiliation(s)
- Angeliki Stamatelatou
- Department of Medical Imaging (766), Radboud University Medical Center Nijmegen, Geert Grooteplein 10, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands.
| | - Tom W J Scheenen
- Department of Medical Imaging (766), Radboud University Medical Center Nijmegen, Geert Grooteplein 10, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - Arend Heerschap
- Department of Medical Imaging (766), Radboud University Medical Center Nijmegen, Geert Grooteplein 10, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| |
Collapse
|
5
|
Gholizadeh N, Pundavela J, Nagarajan R, Dona A, Quadrelli S, Biswas T, Greer PB, Ramadan S. Nuclear magnetic resonance spectroscopy of human body fluids and in vivo magnetic resonance spectroscopy: Potential role in the diagnosis and management of prostate cancer. Urol Oncol 2020; 38:150-173. [PMID: 31937423 DOI: 10.1016/j.urolonc.2019.10.019] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Revised: 09/22/2019] [Accepted: 10/31/2019] [Indexed: 01/17/2023]
Abstract
Prostate cancer is the most common solid organ cancer in men, and the second most common cause of male cancer-related mortality. It has few effective therapies, and is difficult to diagnose accurately. Prostate-specific antigen (PSA), which is currently the most effective diagnostic tool available, cannot reliably discriminate between different pathologies, and in fact only around 30% of patients found to have elevated levels of PSA are subsequently confirmed to actually have prostate cancer. As such, there is a desperate need for more reliable diagnostic tools that will allow the early detection of prostate cancer so that the appropriate interventions can be applied. Nuclear magnetic resonance (NMR) spectroscopy and magnetic resonance spectroscopy (MRS) are 2 high throughput, noninvasive analytical procedures that have the potential to enable differentiation of prostate cancer from other pathologies using metabolomics, by focusing specifically on certain metabolites which are associated with the development of prostate cancer cells and its progression. The value that this type of approach has for the early detection, diagnosis, prognosis, and personalized treatment of prostate cancer is becoming increasingly apparent. Recent years have seen many promising developments in the fields of NMR spectroscopy and MRS, with improvements having been made to hardware as well as to techniques associated with the acquisition, processing, and analysis of related data. This review focuses firstly on proton NMR spectroscopy of blood serum, urine, and expressed prostatic secretions in vitro, and then on 1- and 2-dimensional proton MRS of the prostate in vivo. Major advances in these fields and methodological principles of data collection, acquisition, processing, and analysis are described along with some discussion of related challenges, before prospects that proton MRS has for future improvements to the clinical management of prostate cancer are considered.
Collapse
Affiliation(s)
- Neda Gholizadeh
- School of Health Sciences, Faculty of Health and Medicine, University of Newcastle, Newcastle, NSW, Australia
| | - Jay Pundavela
- Experimental Hematology and Cancer Biology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Rajakumar Nagarajan
- Human Magnetic Resonance Center, Institute for Applied Life Sciences, University of Massachusetts Amherst, MA, USA
| | - Anthony Dona
- Kolling Institute of Medical Research, Royal North Shore Hospital, University of Sydney, St Leonards, NSW, Australia
| | - Scott Quadrelli
- School of Health Sciences, Faculty of Health and Medicine, University of Newcastle, Newcastle, NSW, Australia; Radiology Department, Princess Alexandra Hospital, Brisbane, QLD, Australia
| | - Tapan Biswas
- Department of Instrumentation and Electronics Engineering, Jadavpur University, Kolkata, India
| | - Peter B Greer
- School of Mathematical and Physical Sciences, University of Newcastle, Newcastle, NSW, Australia; Radiation Oncology, Calvary Mater Newcastle, Newcastle, NSW, Australia
| | - Saadallah Ramadan
- School of Health Sciences, Faculty of Health and Medicine, University of Newcastle, Newcastle, NSW, Australia; Imaging Centre, Hunter Medical Research Institute, New Lambton Heights, NSW, Australia.
| |
Collapse
|
6
|
Vidya Shankar R, Chang JC, Hu HH, Kodibagkar VD. Fast data acquisition techniques in magnetic resonance spectroscopic imaging. NMR IN BIOMEDICINE 2019; 32:e4046. [PMID: 30637822 DOI: 10.1002/nbm.4046] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2015] [Revised: 10/30/2018] [Accepted: 10/31/2018] [Indexed: 06/09/2023]
Abstract
Magnetic resonance spectroscopic imaging (MRSI) is an important technique for assessing the spatial variation of metabolites in vivo. The long scan times in MRSI limit clinical applicability due to patient discomfort, increased costs, motion artifacts, and limited protocol flexibility. Faster acquisition strategies can address these limitations and could potentially facilitate increased adoption of MRSI into routine clinical protocols with minimal addition to the current anatomical and functional acquisition protocols in terms of imaging time. Not surprisingly, a lot of effort has been devoted to the development of faster MRSI techniques that aim to capture the same underlying metabolic information (relative metabolite peak areas and spatial distribution) as obtained by conventional MRSI, in greatly reduced time. The gain in imaging time results, in some cases, in a loss of signal-to-noise ratio and/or in spatial and spectral blurring. This review examines the current techniques and advances in fast MRSI in two and three spatial dimensions and their applications. This review categorizes the acceleration techniques according to their strategy for acquisition of the k-space. Techniques such as fast/turbo-spin echo MRSI, echo-planar spectroscopic imaging, and non-Cartesian MRSI effectively cover the full k-space in a more efficient manner per TR . On the other hand, techniques such as parallel imaging and compressed sensing acquire fewer k-space points and employ advanced reconstruction algorithms to recreate the spatial-spectral information, which maintains statistical fidelity in test conditions (ie no statistically significant differences on voxel-wise comparisions) with the fully sampled data. The advantages and limitations of each state-of-the-art technique are reviewed in detail, concluding with a note on future directions and challenges in the field of fast spectroscopic imaging.
Collapse
Affiliation(s)
- Rohini Vidya Shankar
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ, USA
| | - John C Chang
- Banner M D Anderson Cancer Center, Gilbert, AZ, USA
- School for Engineering of Matter, Transport and Energy, Arizona State University, Tempe, AZ, USA
| | - Houchun H Hu
- Department of Radiology and Medical Imaging, Phoenix Children's Hospital, Phoenix, AZ, USA
| | - Vikram D Kodibagkar
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ, USA
| |
Collapse
|
7
|
Han PK, Ma C, Deng K, Hu S, Jee KW, Ying K, Chen YL, El Fakhri G. A minimum-phase Shinnar-Le Roux spectral-spatial excitation RF pulse for simultaneous water and lipid suppression in 1H-MRSI of body extremities. Magn Reson Imaging 2018; 45:18-25. [PMID: 28917812 PMCID: PMC5709164 DOI: 10.1016/j.mri.2017.09.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2017] [Revised: 09/11/2017] [Accepted: 09/12/2017] [Indexed: 02/05/2023]
Abstract
PURPOSE To develop a spectral-spatial (SPSP) excitation RF pulse for simultaneous water and lipid suppression in proton (1H) magnetic resonance spectroscopic imaging (MRSI) of body extremities. METHODS An SPSP excitation pulse is designed to excite Creatine (Cr) and Choline (Cho) metabolite signals while suppressing the overwhelming water and lipid signals. The SPSP pulse is designed using a recently proposed multidimensional Shinnar-Le Roux (SLR) RF pulse design method. A minimum-phase spectral selectivity profile is used to minimize signal loss from T2⁎ decay. RESULTS The performance of the SPSP pulse is evaluated via Bloch equation simulations and phantom experiments. The feasibility of the proposed method is demonstrated using three-dimensional, short repetition-time, free induction decay-based 1H-MRSI in the thigh muscle at 3T. CONCLUSION The proposed SPSP excitation pulse is useful for simultaneous water and lipid suppression. The proposed method enables new applications of high-resolution 1H-MRSI in body extremities.
Collapse
Affiliation(s)
- Paul Kyu Han
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
| | - Chao Ma
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
| | - Kexin Deng
- Biomedical Engineering, Tsinghua University, Beijing, People's Republic of China
| | - Shuang Hu
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States; Department of Nuclear Medicine, West China Hospital, Sichuan University, Sichuan, People's Republic of China
| | - Kyung-Wook Jee
- Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
| | - Kui Ying
- Engineering Physics, Tsinghua University, Beijing, People's Republic of China
| | - Yen-Lin Chen
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States; Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
| | - Georges El Fakhri
- Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States.
| |
Collapse
|
8
|
Lin Y, Lin L, Wei Z, Zhong J, Chen Z. Localized one-dimensional single voxel magnetic resonance spectroscopy without J coupling modulations. Magn Reson Med 2015; 76:1661-1667. [PMID: 26667321 DOI: 10.1002/mrm.26066] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2015] [Revised: 10/26/2015] [Accepted: 10/31/2015] [Indexed: 11/12/2022]
Abstract
PURPOSE To acquire single voxel localized one-dimensional 1 H magnetic resonance spectroscopy (MRS) without J coupling modulations, free from amplitude and phase distortions. METHODS A pulse sequence, named PRESSIR, is developed for volume localized MRS without J modulations at arbitrary echo time (TE). The J coupling evolution is suppressed by the J-refocused module that uses a 90° pulse at the midpoint of a double spin echo. RESULTS The localization performance of the PRESSIR sequence was tested with a two-compartment phantom. The proposed sequence shows similar voxel localization accuracy as PRESS. Both PRESSIR and PRESS sequences were performed on MRS brain phantom and pig brain tissue. PRESS spectra suffer from amplitude and phase distortions due to J modulations, especially under moderate and long TEs, while PRESSIR spectra are almost free from distortions. CONCLUSION The PRESSIR sequence proposed herein enables the acquisition of single voxel in-phase MRS within a single scan. It allows an enhanced signal intensity of J coupling metabolites and reducing undesired broad resonances with short T2s while suppressing J modulations. Moreover, it provides an approach for direct measurement of nonoverlapping J coupling peaks and of transverse relaxation times T2s. Magn Reson Med 76:1661-1667, 2016. © 2015 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Yanqin Lin
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory for Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen, China
| | - Liangjie Lin
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory for Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen, China
| | - Zhiliang Wei
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory for Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen, China
| | - Jianhui Zhong
- Department of Imaging Sciences, University of Rochester, Rochester, New York, USA.,Department of Biomedical Engineering and State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, Zhejiang University, Hangzhou, China
| | - Zhong Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory for Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen, China
| |
Collapse
|
9
|
Feldman RE, Balchandani P. A semiadiabatic spectral-spatial spectroscopic imaging (SASSI) sequence for improved high-field MR spectroscopic imaging. Magn Reson Med 2015; 76:1071-82. [PMID: 26519948 DOI: 10.1002/mrm.26025] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2015] [Revised: 09/08/2015] [Accepted: 10/02/2015] [Indexed: 12/27/2022]
Abstract
PURPOSE MR spectroscopic imaging (MRSI) benefits from operation at 7T due to increased signal-to-noise ratio (SNR) and spectral separation. The 180° radiofrequency (RF) pulses used in the conventional MRSI sequences are particularly susceptible to the variation in the transmitted RF (B1 ) field and severe chemical shift localization errors at 7T. RF power deposition, as measured by specific absorption rate (SAR), also increases with field strength. Adiabatic 180° RF pulses may mitigate the effects of B1 variation. We designed and implemented a semiadiabatic spectral-spatial spectroscopic imaging (SASSI) pulse sequence to provide more uniform spectral data at 7T with reduced SAR. METHODS The adiabatic Shinnar-Le Roux algorithm was used to generate a high bandwidth 180° adiabatic spectral-spatial (SPSP) pulse that captured a spectral range containing the main metabolites of interest. A pair of 180° SPSP pulses was used to refocus the signal excited by a 90° SPSP pulse in order to select a 3D volume of interest in the SASSI sequence. RESULTS The SASSI pulse sequence produced spectra with more uniform brain metabolite SNR when compared with the conventional nonadiabatic MRSI sequence. CONCLUSION SASSI achieved comparable SNR to the current adiabatic alternative, semi-LASER, but with 1/3 of the SAR. Magn Reson Med 76:1071-1082, 2016. © 2015 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Rebecca E Feldman
- Translational and Molecular Imaging Institution, Icahn School of Medicine at Mount Sinai, New York, New York, USA.
| | - Priti Balchandani
- Translational and Molecular Imaging Institution, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| |
Collapse
|
10
|
Lin M, Kumar A, Yang S. Two-dimensional J-resolved LASER and semi-LASER spectroscopy of human brain. Magn Reson Med 2015; 71:911-20. [PMID: 23605818 DOI: 10.1002/mrm.24732] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
PURPOSE Two-dimensional J-resolved localized and semi-localized by adiabatic selective refocusing (LASER and semi-LASER) spectroscopy, named "J-resolved LASER" and "J-resolved semi-LASER", were introduced to suppress chemical shift artifacts, additional J-refocused artifactual peaks from spatially dependent J-coupling evolution, and sensitivity to radiofrequency (RF) field inhomogeneity. METHODS Three pairs of adiabatic pulses were employed for voxel localization in J-resolved LASER and two pairs in J-resolved semi-LASER. The first half of t1 period was inserted between the last pair of adiabatic pulses, which was proposed in this work to obtain two-dimensional adiabatic J-resolved spectra of human brain for the first time. Phantom and human experiments were performed to demonstrate their feasibility and advantages over conventional J-resolved spectroscopy (JPRESS). RESULTS Compared to JPRESS, J-resolved LASER or J-resolved semi-LASER exhibited significant suppression of chemical shift artifacts and additional J-refocused peaks from spatially dependent J-coupling evolution, and demonstrated insensitivity to the change of RF frequency offset over large bandwidth. CONCLUSION Experiments on phantoms and human brains verified the feasibility and strengths of two-dimensional adiabatic J-resolved spectroscopy at 3T. This technique is expected to advance the application of in vivo two-dimensional MR spectroscopy at 3T and higher field strengths for more reliable and accurate quantification of metabolites.
Collapse
Affiliation(s)
- Meijin Lin
- Department of Psychiatry, University of Illinois at Chicago, Chicago, Illinois, USA
| | | | | |
Collapse
|
11
|
Pradhan S, Bonekamp S, Gillen JS, Rowland LM, Wijtenburg SA, Edden RAE, Barker PB. Comparison of single voxel brain MRS AT 3T and 7T using 32-channel head coils. Magn Reson Imaging 2015; 33:1013-8. [PMID: 26117693 PMCID: PMC4549223 DOI: 10.1016/j.mri.2015.06.003] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2014] [Revised: 06/12/2015] [Accepted: 06/20/2015] [Indexed: 11/23/2022]
Abstract
PURPOSE The purpose of this study was to compare magnetic resonance spectroscopy (MRS) of three different regions of the human brain between 3 and 7 Tesla, using the same subjects and closely matched methodology at both field strengths. METHODS A semi-LASER (sLASER) pulse sequence with TE 32ms was used to acquire metabolite spectrum along with the water reference at 3T and 7T using similar experimental parameters and hardware at both field strengths (n=4 per region and field). Spectra were analyzed in LCModel using a simulated basis set. RESULTS Signal-to-noise ratio (SNR) at 7T was higher compared to 3T, and linewidths (in ppm) at both field strengths were comparable in ppm scale. Of the 13 metabolites reported in the paper, most metabolites were measured with higher precision at 7T in all three regions. CONCLUSION The study confirms gains in SNR and measurement precision at 7T in all three representative brain regions using the sLASER pulse sequence coupled with a 32-channel phased-array head coil.
Collapse
Affiliation(s)
- Subechhya Pradhan
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
| | - Susanne Bonekamp
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Joseph S Gillen
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA; F.M. Kirby Research Centre, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Laura M Rowland
- Maryland Psychiatric Research Center, Department of Psychiatry, University of Maryland School of Medicine, Baltimore, MD, USA
| | - S Andrea Wijtenburg
- Maryland Psychiatric Research Center, Department of Psychiatry, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Richard A E Edden
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Peter B Barker
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA; F.M. Kirby Research Centre, Kennedy Krieger Institute, Baltimore, MD, USA
| |
Collapse
|
12
|
Lin M, Kumar A, Yang S. Two-dimensional semi-LASER correlation spectroscopy with well-maintained cross peaks. Magn Reson Med 2013; 72:26-32. [PMID: 24123233 DOI: 10.1002/mrm.24933] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2013] [Revised: 07/28/2013] [Accepted: 08/01/2013] [Indexed: 11/07/2022]
Abstract
PURPOSE To demonstrate that the limited bandwidth of the second 90° radiofrequency (RF) pulse in two-dimensional (2D) localized correlation spectroscopy (L-COSY) induces spatially dependent magnetization transfer that results in attenuated cross-peaks, and to propose a new 2D semi-adiabatically localized COSY sequence to solve this problem. METHODS AND THEORY A semi-localization by adiabatic selective refocusing (semi-LASER or sLASER) method was incorporated into the COSY sequence with the slice-selective first 90° RF pulse and the non-slice-selective second 90° RF pulse to form a new 2D sLASER localized COSY sequence, named "sLASER-first-COSY," to solve the problem of spatially dependent magnetization transfer. Experiments were performed to verify the feasibility and advantages of sLASER-first-COSY sequence over a recently reported other sLASER COSY sequence with a slice-selective second 90° RF pulse, named "sLASER-last-COSY". RESULTS Phantom, ex vivo, and in vivo human brain experiments demonstrated that sLASER-first-COSY yielded stronger cross peaks and higher ratios of cross peak volumes to diagonal peak volumes than sLASER-last-COSY. CONCLUSION As COSY relies on the cross peaks to obtain larger dispersion of peaks for quantification, the new sLASER-first-COSY sequence yielding well-maintained cross peaks will facilitate more reliable and accurate quantification of metabolites with coupled spin systems.
Collapse
Affiliation(s)
- Meijin Lin
- University of Illinois at Chicago, Department of Psychiatry, Chicago, Illinois, USA
| | | | | |
Collapse
|
13
|
Arteaga de Castro CS, Boer VO, Andreychenko A, Wijnen JP, van der Heide UA, Luijten PR, Klomp DWJ. Improved efficiency on editing MRS of lactate and γ-aminobutyric acid by inclusion of frequency offset corrected inversion pulses at high fields. NMR IN BIOMEDICINE 2013; 26:1213-1219. [PMID: 23508792 DOI: 10.1002/nbm.2937] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2012] [Revised: 02/06/2013] [Accepted: 02/07/2013] [Indexed: 06/01/2023]
Abstract
γ-Aminobutyric acid (GABA) and lactate are metabolites which are present in the brain. These metabolites can be indicators of psychiatric disorders or tumor hypoxia, respectively. The measurement of these weakly coupled spin systems can be performed using MRS editing techniques; however, at high field strength, this can be challenging. This is due to the low available B1 (+) field at high fields, which results in narrow-bandwidth refocusing pulses and, consequently, in large chemical shift displacement artifacts. In addition, as a result of the increased chemical shift displacement artifacts and chemical shift dispersion, the efficiency of the MRS method is reduced, even when using adiabatic refocusing pulses. To overcome this limitation, frequency offset corrected inversion (FOCI) pulses have been suggested as a mean to substantially increase the bandwidth of adiabatic pulses. In this study, a Mescher-Garwood semi-localization by adiabatic selection and refocusing (MEGA-sLASER) editing sequence with refocusing FOCI pulses is presented for the measurement of GABA and lactate in the human brain. Metabolite detection efficiencies were improved by 20% and 75% for GABA and lactate, respectively, when compared with editing techniques that employ adiabatic radiofrequency refocusing pulses. The highly efficient MEGA-sLASER sequence with refocusing FOCI pulses is an ideal and robust MRS editing technique for the measurement of weakly coupled metabolites at high field strengths.
Collapse
|
14
|
Moore J, Jankiewicz M, Anderson AW, Gore JC. Evaluation of non-selective refocusing pulses for 7 T MRI. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2012; 214:212-20. [PMID: 22177384 PMCID: PMC3257423 DOI: 10.1016/j.jmr.2011.11.010] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2011] [Revised: 10/11/2011] [Accepted: 11/10/2011] [Indexed: 05/08/2023]
Abstract
There is a continuing need for improved RF pulses that achieve proper refocusing in the context of ultra-high field (≥ 7 T) human MRI. Simple block or sinc pulses are highly susceptible to RF field inhomogeneities, and adiabatic pulses are generally considered too SAR intensive for practical use at 7 T. The performance of the array of pulses falling between these extremes, however, has not been systematically evaluated. The aim of this work was to compare the performances of 21 non-selective refocusing pulses spanning a range of durations and SAR levels. The evaluation was based upon simulations and both phantom and in vivo human brain experiments conducted at 7 T. Tested refocusing designs included block, composite block, BIR-4, hyperbolic secant, and numerically optimized composite waveforms. These pulses were divided into three SAR classes and two duration categories, and, based on signal gain in a 3-D spin echo sequence, practical recommendations on usage are made within each category. All evaluated pulses were found to produce greater volume-averaged signals relative to a 180° block pulse. Although signal gains often come with the price of increased SAR or duration, some pulses were found to result in significant signal enhancement while also adhering to practical constraints. This work demonstrates the signal gains and losses realizable with single-channel refocusing pulse designs and should assist in the selection of suitable refocusing pulses for practical 3-D spin-echo imaging at 7 T. It further establishes a reference against which future pulses and multi-channel designs can be compared.
Collapse
Affiliation(s)
- Jay Moore
- Vanderbilt University Institute of Imaging Science, 1161 21st Ave. South, MCN AA-1105, Nashville, TN 37232-2310
- Department of Radiology and Radiological Sciences, Vanderbilt University, 116 21st Ave. South, MCN CCC-1106, Nashville, TN 37232-2675
| | - Marcin Jankiewicz
- Vanderbilt University Institute of Imaging Science, 1161 21st Ave. South, MCN AA-1105, Nashville, TN 37232-2310
- Department of Radiology and Radiological Sciences, Vanderbilt University, 116 21st Ave. South, MCN CCC-1106, Nashville, TN 37232-2675
| | - Adam W. Anderson
- Vanderbilt University Institute of Imaging Science, 1161 21st Ave. South, MCN AA-1105, Nashville, TN 37232-2310
- Department of Radiology and Radiological Sciences, Vanderbilt University, 116 21st Ave. South, MCN CCC-1106, Nashville, TN 37232-2675
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, VU Station B 351631, Nashville, TN 37232
| | - John C. Gore
- Vanderbilt University Institute of Imaging Science, 1161 21st Ave. South, MCN AA-1105, Nashville, TN 37232-2310
- Department of Radiology and Radiological Sciences, Vanderbilt University, 116 21st Ave. South, MCN CCC-1106, Nashville, TN 37232-2675
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, VU Station B 351631, Nashville, TN 37232
| |
Collapse
|
15
|
Park B, Lizak MJ, Xiang Y, Shen J. Slice with angulated non-parallel boundaries. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2011; 210:98-106. [PMID: 21396862 PMCID: PMC3081426 DOI: 10.1016/j.jmr.2011.02.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2010] [Revised: 02/15/2011] [Accepted: 02/15/2011] [Indexed: 05/30/2023]
Abstract
Adiabatic pulses are widely used for spatial localization in magnetic resonance spectroscopy because of their high immunity to RF inhomogeneity and excellent slice profiles. Since non-rectangular volume is often preferred in localized spectroscopy, we propose a scheme for selecting a trapezoidal slice using adiabatic π pulses. In this scheme, a time-varying gradient orthogonal to a stationary slice selection gradient is used to change the boundaries of the slice profile from parallel to non-parallel. Numerical simulation results for the transverse and longitudinal magnetization using different RF and gradient waveforms are presented for non-parallel slice selection. Phantom imaging and in vivo(1)H MRS of rat brain using non-parallel slices are demonstrated.
Collapse
Affiliation(s)
- Busik Park
- Molecular Imaging Branch, National Institute of Mental Health, Intramural Research Program, NIH, Bethesda, MD, USA.
| | | | | | | |
Collapse
|
16
|
Andronesi OC, Ramadan S, Ratai EM, Jennings D, Mountford CE, Sorensen AG. Spectroscopic imaging with improved gradient modulated constant adiabaticity pulses on high-field clinical scanners. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2010; 203:283-93. [PMID: 20163975 PMCID: PMC3214007 DOI: 10.1016/j.jmr.2010.01.010] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2009] [Revised: 01/16/2010] [Accepted: 01/19/2010] [Indexed: 05/06/2023]
Abstract
The purpose of this work was to design and implement constant adiabaticity gradient modulated pulses that have improved slice profiles and reduced artifacts for spectroscopic imaging on 3T clinical scanners equipped with standard hardware. The newly proposed pulses were designed using the gradient offset independent adiabaticity (GOIA, Tannus and Garwood[13]) method using WURST modulation for RF and gradient waveforms. The GOIA-WURST pulses were compared with GOIA-HSn (GOIA based on nth-order hyperbolic secant) and FOCI (frequency offset corrected inversion) pulses of the same bandwidth and duration. Numerical simulations and experimental measurements in phantoms and healthy volunteers are presented. GOIA-WURST pulses provide improved slice profile that have less slice smearing for off-resonance frequencies compared to GOIA-HSn pulses. The peak RF amplitude of GOIA-WURST is much lower (40% less) than FOCI but slightly higher (14.9% more) to GOIA-HSn. The quality of spectra as shown by the analysis of lineshapes, eddy currents artifacts, subcutaneous lipid contamination and SNR is improved for GOIA-WURST. GOIA-WURST pulse tested in this work shows that reliable spectroscopic imaging could be obtained in routine clinical setup and might facilitate the use of clinical spectroscopy.
Collapse
Affiliation(s)
- Ovidiu C. Andronesi
- Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02114
- Address correspondence/reprints request to: Ovidiu C. Andronesi or A. Gregory Sorensen, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, 149 Thirteenth Street, Suite 2301, Boston, MA 02129, USA; ; , Tel: 617-643-6864; Fax: 617 726-7422
| | - Saadallah Ramadan
- Center for Clinical Spectroscopy, Department of Radiology, Brigham & Women’s Hospital, Harvard Medical School, Boston, MA 02115
| | - Eva-Maria Ratai
- Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02114
| | - Dominique Jennings
- Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02114
| | - Carolyn E. Mountford
- Center for Clinical Spectroscopy, Department of Radiology, Brigham & Women’s Hospital, Harvard Medical School, Boston, MA 02115
| | - A. Gregory Sorensen
- Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02114
- Address correspondence/reprints request to: Ovidiu C. Andronesi or A. Gregory Sorensen, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, 149 Thirteenth Street, Suite 2301, Boston, MA 02129, USA; ; , Tel: 617-643-6864; Fax: 617 726-7422
| |
Collapse
|
17
|
Near J, Romagnoli C, Curtis AT, Klassen LM, Izawa J, Chin J, Bartha R. High-field MRSI of the prostate using a transmit/receive endorectal coil and gradient modulated adiabatic localization. J Magn Reson Imaging 2009; 30:335-43. [PMID: 19629986 DOI: 10.1002/jmri.21841] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
PURPOSE To demonstrate in vivo magnetic resonance spectroscopic imaging (MRSI) of the human prostate at 4.0T using a transmit/receive endorectal coil and a pulse sequence designed specifically for this application. MATERIALS AND METHODS A solid, reusable endorectal probe was designed for both radiofrequency transmission and reception. Finite difference time domain (FDTD) simulations were performed to characterize the coil's electric field distribution, and temperature measurements were performed in a beef tissue phantom to determine the coil's safe operating limit. The localization by selective adiabatic refocusing (LASER) pulse sequence was implemented using six gradient modulated offset independent adiabatic (GOIA) pulses for very sharp, B(1)-insensitive voxel localization. RESULTS Based on the simulations and temperature measurements, the coil's safe operating limit was conservatively estimated to be 1.0W for 15 minutes. The transition width of the GOIA pulse selection profiles was only 6% of the bandwidth, compared with 22% for a specific absorption rate (SAR)-matched conventional adiabatic pulse. Using the coil and pulse sequence described here, MRSI data were successfully acquired from a patient with biopsy-proven prostate cancer, with a nominal voxel size of 0.34 cc in a scan time of 15 minutes. CONCLUSION This work demonstrates the safe and effective use of a transmit/receive endorectal coil for in vivo MRSI of the prostate.
Collapse
Affiliation(s)
- Jamie Near
- Department of Medical Biophysics, University of Western Ontario, London, Ontario, Canada
| | | | | | | | | | | | | |
Collapse
|
18
|
Jissendi Tchofo P, Balériaux D. Brain 1H-MR spectroscopy in clinical neuroimaging at 3T. J Neuroradiol 2009; 36:24-40. [DOI: 10.1016/j.neurad.2008.04.001] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
19
|
Abstract
Frequency-modulated (FM) pulses have practical advantages for spin-echo experiments, such as the ability to produce a broadband pi rotation, with an inhomogeneous radiofrequency (RF) field. However, such use leads to a nonlinear phase of the transverse magnetization, which is why FM pulses like the hyperbolic secant (HS) pulse are not commonly used for multislice spin-echo magnetic resonance imaging (MRI). Here, a general theory and methods are described for conventional spin-echo imaging using a pi HS pulse for refocusing. Phase profiles produced by the HS pulse are analytically described. The analysis is extended to yield the specific relationships between pulse parameters and gradients, which must be satisfied to compensate the nonlinear phase variation produced with a spin-echo sequence composed of pi/2 and pi HS pulses (the pi/2 HS - pi HS sequence). The latter offers advantages for multislice spin-echo MRI, including excellent slice-selection and partial compensation for RF inhomogeneity. Furthermore, it can be implemented with a shorter echo time and lower power deposition than a previously described method using a pair of pi HS pulses.
Collapse
Affiliation(s)
- Jang-Yeon Park
- The Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota 55455, USA.
| | | |
Collapse
|
20
|
Hoult DI, Foreman D, Kolansky G, Kripiakevich D. Overcoming high-field RF problems with non-magnetic Cartesian feedback transceivers. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2007; 21:15-29. [PMID: 18026763 DOI: 10.1007/s10334-007-0089-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2007] [Revised: 09/11/2007] [Accepted: 10/17/2007] [Indexed: 12/24/2022]
Abstract
In extending human MR to field strengths approaching 10 T, the wavelength of electromagnetic radiation at the proton Larmor frequency becomes less than human body size and conventional radio-frequency coil circumference. Consequently, radio-frequency magnetic fields are better generated by an array of small coils than by one large coil. In this article, the primary problem of array coil interactions during transmission is examined, and a standard proposed whereby secondary induced currents should be less than 1% of the primary coil current. The use of cancellation methods and of power amplifiers with high output impedance to reduce interactions is examined in the light of this standard and found wanting. Non-magnetic Cartesian feedback transceivers functioning at the magnet entrance are then proposed as a solution that both reduces instrumentation cost and increases the bandwidth over which the standard may be met. The compromises inherent in instrument design are detailed and examples given of the innovative circuitry used. It is shown experimentally that when connected to interacting coils, two Cartesian feedback instruments function stably in accord with theory and such that the proposed standard is typically attained over a bandwidth of 22 kHz during transmission (much greater during signal reception)-enough for all current MR protocols.
Collapse
Affiliation(s)
- D I Hoult
- Institute for Biodiagnostics, National Research Council Canada, 435 Ellice Avenue, Winnipeg, MB, R3B 1Y6, Canada.
| | | | | | | |
Collapse
|
21
|
Valette J, Park JY, Gröhn O, Uğurbil K, Garwood M, Henry PG. Spectroscopic imaging with volume selection by unpaired adiabatic pi pulses: theory and application. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2007; 189:1-12. [PMID: 17851103 DOI: 10.1016/j.jmr.2007.08.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2007] [Revised: 08/10/2007] [Accepted: 08/10/2007] [Indexed: 05/17/2023]
Abstract
In NMR spectroscopy, volume selection can be advantageously achieved using adiabatic pi pulses, which enable high bandwidth and B(1) insensitivity. In order to avoid the generation of non-linear phase profiles and the subsequent signal loss caused by incoherent averaging, adiabatic pi pulses are usually used in pairs for volume selection in each spatial dimension. Alternatively, when performing spectroscopic imaging (SI), a high enough spatial resolution results in negligible phase dispersion within each pixel. This allows using only one pulse per selected spatial dimension, resulting in a reduced echo-time and reduced power deposition. In this work, the feasibility of such an approach is explored theoretically and numerically, allowing the derivation of explicit conditions to obtain SI images without artifact. Adequate spatial and spectral post-processing procedures are described to compensate for the effect of non-linear phase profiles. These developments are applied to SI in the rat brain at 9.4 T, using a new adiabatic sequence named Pseudo-LASER.
Collapse
Affiliation(s)
- Julien Valette
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, 2021 Sixth Street SE, Minneapolis, MN 55455, USA.
| | | | | | | | | | | |
Collapse
|