1
|
Dong Y, Atkinson D, Koolstra K, van Osch MJP, Börnert P. Chemical shift-encoded multishot EPI for navigator-free prostate DWI. Magn Reson Med 2025; 93:1059-1076. [PMID: 39402739 DOI: 10.1002/mrm.30334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 09/12/2024] [Accepted: 09/22/2024] [Indexed: 12/29/2024]
Abstract
PURPOSE DWI is an important contrast for prostate MRI to enable early and accurate detection of cancer. This study introduces a Dixon 3-shot-EPI protocol with structured low-rank reconstruction for navigator-free DWI. The aim is to overcome the limitations of single-shot EPI (ssh-EPI), such as geometric distortions and fat signal interference, while addressing the motion-induced phase variations of multishot EPI and simultaneously allowing water/fat separation. METHODS DWI data were acquired from 7 healthy volunteers using both Dixon 3-shot EPI and standard fat-suppressed ssh-EPI with similar scan times for comparison. Two readers evaluated image quality using a 5-point Likert scale regarding different aspects. The ADC values were quantitatively compared between protocols. To show feasibility in a clinical setting, the protocol was applied to two patients. RESULTS From the reader scores, Dixon 3-shot EPI significantly reduced geometric distortion compared with ssh-EPI (p < 0.01), with no significant differences in edge definition, SNR, or overall image quality. There was no significant difference in ADC values between the two protocols. However, the Dixon multishot-EPI protocol offered advantages such as self-referenced B0 map-driven distortion correction, greater flexibility in imaging parameters, and superior fat suppression. In the patient data, the lesion could be clearly identified in both protocols and on the associated ADC maps. CONCLUSION The proposed Dixon 3-shot-EPI protocol shows promise as an alternative to ssh-EPI for prostate DWI, providing reduced geometric distortions and improved fat suppression. It addresses common DWI issues based on EPI and enhances scanning flexibility, indicating potential for optimized imaging.
Collapse
Affiliation(s)
- Yiming Dong
- C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - David Atkinson
- Center for Medical Imaging, University College London, London, UK
| | | | - Matthias J P van Osch
- C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Peter Börnert
- C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
- Philips Research Hamburg, Hamburg, Germany
| |
Collapse
|
2
|
Meng Y, Allen JW, Sharghi VK, Qiu D. Motion and temporal B 0-shift corrections for QSM and R 2 * mapping using dual-echo spiral navigators and conjugate-phase reconstruction. Magn Reson Med 2025; 93:199-212. [PMID: 39233495 DOI: 10.1002/mrm.30266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 08/03/2024] [Accepted: 08/05/2024] [Indexed: 09/06/2024]
Abstract
PURPOSE To develop an efficient navigator-based motion and temporal B0-shift correction technique for 3D multi-echo gradient-echo (ME-GRE) MRI for quantitative susceptibility mapping (QSM) andR 2 * $$ {\mathrm{R}}_2^{\ast } $$ mapping. THEORY AND METHODS A dual-echo 3D stack-of-spiral navigator was designed to interleave with the Cartesian multi-echo gradient-echo acquisitions, allowing the acquisition of both low-echo and high-echo time signals. We additionally designed a novel conjugate phase-based reconstruction method for the joint correction of motion and temporal B0 shifts. We performed numerical simulation, phantom scans, and in vivo human scans to assess the performance of the methods. RESULTS Numerical simulation and human brain scans demonstrated that the proposed technique successfully corrected artifacts induced by both head motions and temporal B0 changes. Efficient B0-change correction with conjugate-phase reconstruction can be performed on fewer than 10 clustered k-space segments. In vivo scans showed that combining temporal B0 correction with motion correction further reduced artifacts and improved image quality in bothR 2 * $$ {\mathrm{R}}_2^{\ast } $$ and QSM images. CONCLUSION Our proposed approach of using 3D spiral navigators and a novel conjugate-phase reconstruction method can improve susceptibility-related measurements using MR.
Collapse
Affiliation(s)
- Yuguang Meng
- Department of Radiology and Imaging Sciences, Emory University, Atlanta, Georgia, USA
| | - Jason W Allen
- Department of Radiology and Imaging Sciences, Emory University, Atlanta, Georgia, USA
- Department of Radiology and Imaging Sciences, Indiana University, Indianapolis, Indiana, USA
- Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia, USA
| | | | - Deqiang Qiu
- Department of Radiology and Imaging Sciences, Emory University, Atlanta, Georgia, USA
- Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia, USA
| |
Collapse
|
3
|
Klodowski K, Sengupta A, Dragonu I, Rodgers CT. Prospective 3D Fat Navigator (FatNav) motion correction for 7T Terra MRI. NMR IN BIOMEDICINE 2025; 38:e5283. [PMID: 39460596 PMCID: PMC11602639 DOI: 10.1002/nbm.5283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Revised: 10/09/2024] [Accepted: 10/10/2024] [Indexed: 10/28/2024]
Abstract
Ultra-high field (7T) MRI allows scans at sub-millimetre resolution with exquisite signal-to-noise ratio (SNR). As 7T MRI becomes more widely used clinically, the challenge of patient motion must be overcome. Retrospective motion correction is used successfully for some protocols, but for acquisitions such as slice-by-slice scans only prospective motion correction can deliver the full potential of 7T MRI. We report the first implementation of prospective 3D Fat Navigator ("FatNav") motion correction for the Siemens 7T Terra MRI. We implemented a modular Sequence Building Block for FatNav and embedded it into the vendor's gradient-recalled echo (GRE) sequence. We modified the reconstruction pipeline to reconstruct FatNav images online, coregistering them and sending motion updates to the host sequence online. We tested five registration algorithms for performance and accuracy on synthetic FatNav data. We implemented the best three of these in our sequence and tested them online. We acquired T1 and T2* weighted brain images of healthy volunteers correcting every other image for motion to visualise the effectiveness of online motion correction. Data were acquired with and without head immobilisation. We also tested performance while correcting every measurement for motion. Our implementation uses a 1.23 s 3D FatNav acquisition module and delivers motion updates in less than 3 s, which is sufficient for motion updates every few k-space lines in typical scans. Corrected images are crisper with fewer visible motion artefacts. This improved sharpness is reflected quantitatively by an increase in the variance of the image Laplacian which is 1.59 x better for corrected vs uncorrected images. Profiles across the cerebral falx are 33% steeper for corrected vs uncorrected images. Prospective FatNav improves GRE image quality in the brain. Our modular Sequence Building Block provides a simple method to integrate motion correction in 7T MRI pulse sequences.
Collapse
Affiliation(s)
| | - Ayan Sengupta
- Department of Psychology, Royal HollowayUniversity of LondonLondonUK
| | | | | |
Collapse
|
4
|
Weber S, Stoffel N, Ansede-Bermejo J, Cruz R, Del Real Bolt Á, Bruckmaier R, Carracedo Á, Aybek S. Salivary oxytocin and amygdalar alterations in functional neurological disorders. Brain Commun 2024; 7:fcae455. [PMID: 39726815 PMCID: PMC11670354 DOI: 10.1093/braincomms/fcae455] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Revised: 11/09/2024] [Accepted: 12/13/2024] [Indexed: 12/28/2024] Open
Abstract
Individuals diagnosed with functional neurological disorder experience abnormal movement, gait, sensory processing or functional seizures, for which research into the pathophysiology identified psychosocial contributing factors as well as promising biomarkers. Recent pilot studies suggested that (epi-)genetic variants may act as vulnerability factors, for example, on the oxytocin pathway. This study set out to explore endogenous oxytocin hormone levels in saliva in a cohort of 59 functional neurological disorder patients and 65 healthy controls comparable in sex and age. First, we examined the association between salivary oxytocin levels with the genetic allelic variant (rs53576) of the oxytocin receptor gene (OXTR), its epigenetic changes indicated by methylation rates, and clinical variables-including childhood trauma. Second, due to previously reported effects of oxytocin changing the volume and functional connectivity of the amygdala, as well as the known involvement of the amygdala in the pathophysiology of functional neurological disorders, we further looked at both structural and functional imaging of the amygdala. While patients did not significantly differ from healthy control in their peripheral oxytocin levels, there was a specific interaction of OXTR methylation and peripheral oxytocin dependent on group: higher methylation rates correlated with higher salivary oxytocin in patients only, while this was not the case in healthy control [F(1109) = 8.92, P = 0.003, d = 0.541]. Moreover, patients with the AA-genotype (minor allele) of the rs53576 genetic variant of the OXTR gene presented with higher OXTR methylation levels [F(2106) = 10.25, P < 0.0001, d = 0.58]. Lastly, amygdalar connectivity to the hippocampus, the posterior cingulate cortex, the inferior parietal cortex and the inferior temporal cortex as well as smaller amygdalar volume were correlated to peripheral oxytocin levels in patients only [F(2,38) = 5.36, P = 0.025, d = 0.431], but not in healthy control. No significant interactions with childhood trauma were identified. Our study revealed a significant interplay between peripheral oxytocin and OXTR methylation in patients only, potentially influenced by genotype. One could hypothesize that higher peripheral oxytocin denotes a compensatory mechanisms for the increased methylation of the OXTR, which might affect amygdalar functional connectivity. These findings help to further understand underlying pathophysiological mechanisms, considering oxytocin's involvement in functional patients and could offer a potential site of treatment for future studies.
Collapse
Affiliation(s)
- Samantha Weber
- Department of Neurology, Psychosomatic Medicine Unit, Inselspital Bern University Hospital, University of Bern, Bern 3012, Switzerland
- Department of Adult Psychiatry and Psychotherapy, University Hospital of Psychiatry Zurich, Zurich 8032, Switzerland
| | - Natascha Stoffel
- Department of Neurology, Psychosomatic Medicine Unit, Inselspital Bern University Hospital, University of Bern, Bern 3012, Switzerland
- Faculty of Science and Medicine, University of Fribourg, Fribourg 1700, Switzerland
- Graduate School of Health Science (GHS), University of Bern, Bern 3013, Switzerland
| | - Juan Ansede-Bermejo
- Centro Nacional de Genotipado (CEGEN), Universidade de Santiago de Compostela, Santiago de Compostela 15706, Spain
| | - Raquel Cruz
- Centro Nacional de Genotipado (CEGEN), Universidade de Santiago de Compostela, Santiago de Compostela 15706, Spain
- Centre for Biomedical Network Research on Rare Diseases (CIBERER), Instituto de Salud Carlos III, Madrid 28029, Spain
- Instituto de Investigación Sanitaria de Santiago (IDIS), Hospital Clínico Universitario de Santiago (CHUS), Santiago de Compostela 15706, Spain
- Centro Singular de Investigación en Medicina Molecular y Enfermedades Crónicas (CIMUS), Universidade de Santiago de Compostela, Santiago de Compostela 15706, Spain
| | - Álvaro Del Real Bolt
- Medicine and Psychiatry Department, University of Cantabria, Santander 39005, Spain
| | - Rupert Bruckmaier
- Veterinary Physiology, Vetsuisse Faculty, University of Bern, Bern 3012, Switzerland
| | - Ángel Carracedo
- Centro Nacional de Genotipado (CEGEN), Universidade de Santiago de Compostela, Santiago de Compostela 15706, Spain
- Centre for Biomedical Network Research on Rare Diseases (CIBERER), Instituto de Salud Carlos III, Madrid 28029, Spain
- Instituto de Investigación Sanitaria de Santiago (IDIS), Hospital Clínico Universitario de Santiago (CHUS), Santiago de Compostela 15706, Spain
- Centro Singular de Investigación en Medicina Molecular y Enfermedades Crónicas (CIMUS), Universidade de Santiago de Compostela, Santiago de Compostela 15706, Spain
- Fundación Pública Galega de Medicina Xenómica, Sistema Galego de Saúde (SERGAS), Santiago de Compostela 15706, Spain
| | - Selma Aybek
- Faculty of Science and Medicine, University of Fribourg, Fribourg 1700, Switzerland
| |
Collapse
|
5
|
Sun Y, Wang L, Li G, Lin W, Wang L. A foundation model for enhancing magnetic resonance images and downstream segmentation, registration and diagnostic tasks. Nat Biomed Eng 2024:10.1038/s41551-024-01283-7. [PMID: 39638876 DOI: 10.1038/s41551-024-01283-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 10/17/2024] [Indexed: 12/07/2024]
Abstract
In structural magnetic resonance (MR) imaging, motion artefacts, low resolution, imaging noise and variability in acquisition protocols frequently degrade image quality and confound downstream analyses. Here we report a foundation model for the motion correction, resolution enhancement, denoising and harmonization of MR images. Specifically, we trained a tissue-classification neural network to predict tissue labels, which are then leveraged by a 'tissue-aware' enhancement network to generate high-quality MR images. We validated the model's effectiveness on a large and diverse dataset comprising 2,448 deliberately corrupted images and 10,963 images spanning a wide age range (from foetuses to elderly individuals) acquired using a variety of clinical scanners across 19 public datasets. The model consistently outperformed state-of-the-art algorithms in improving the quality of MR images, handling pathological brains with multiple sclerosis or gliomas, generating 7-T-like images from 3 T scans and harmonizing images acquired from different scanners. The high-quality, high-resolution and harmonized images generated by the model can be used to enhance the performance of models for tissue segmentation, registration, diagnosis and other downstream tasks.
Collapse
Affiliation(s)
- Yue Sun
- Developing Brain Computing Lab, Department of Radiology and Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC, USA
| | - Limei Wang
- Developing Brain Computing Lab, Department of Radiology and Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC, USA
| | - Gang Li
- Department of Radiology and Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
| | - Weili Lin
- Department of Radiology and Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
| | - Li Wang
- Developing Brain Computing Lab, Department of Radiology and Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.
| |
Collapse
|
6
|
Sengupta S, Glenn A, Rogers BP. Prospective head motion correction at 3 Tesla with wireless NMR markers and ultrashort echo navigators. Magn Reson Imaging 2024; 114:110238. [PMID: 39276809 DOI: 10.1016/j.mri.2024.110238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2024] [Revised: 08/28/2024] [Accepted: 09/10/2024] [Indexed: 09/17/2024]
Abstract
PURPOSE Prospective motion correction (PMC) with inductively-coupled wireless NMR markers has been shown to be an effective plug-and-play method for dealing with head motion at 7 Tesla [29,30]. However, technical challenges such as one-to-one identification of three wireless markers, generation of hyper-intense marker artifacts and low marker peak SNR in the navigators has limited the adoption of this technique. The goal of this work is to introduce solutions to overcome these issues and extend this technique to PMC for brain imaging at 3 Tesla. METHODS PMC with 6 degrees of freedom (DOF) was implemented using a novel ∼8 ms, ultrashort echo time (UTE) navigator in concert with optimally chosen MnCl2 marker samples to minimize marker artifacts. Distinct head coil sensitivities were leveraged to enable identification and tracking of individual markers and a variable flip angle (VFA) scheme and real time filtering were used to boost marker SNR. PMC was performed in 3D T1 weighted brain imaging at 3 Tesla with voluntary head motions in adult volunteers. RESULTS PMC with wireless markers improved image quality in 3D T1 weighted images in all subjects compared to non-motion corrected images for similar motions with no noticeable marker artifacts. Precision of motion tracking was found to be in the range of 0.01-0.06 mm/degrees. Navigator execution had minimal impact on sequence duration. CONCLUSIONS Wireless NMR markers provide an accurate, calibration-free and economical option for 6 DOF PMC in brain imaging across field strengths. Challenges in this technique can be addressed by combining navigator design, sample selection and real time data processing strategies.
Collapse
Affiliation(s)
- Saikat Sengupta
- Vanderbilt University Institute of Imaging Science,Vanderbilt University Medical Center, Nashville, TN 37235, USA; Department of Radiology and Radiological Sciences,Vanderbilt University Medical Center, Nashville, TN 37235, USA.
| | - Antonio Glenn
- Department of Biomedical Engineering, Case Western Reserve University Cleveland, OH 44106, USA
| | - Baxter P Rogers
- Vanderbilt University Institute of Imaging Science,Vanderbilt University Medical Center, Nashville, TN 37235, USA; Department of Radiology and Radiological Sciences,Vanderbilt University Medical Center, Nashville, TN 37235, USA
| |
Collapse
|
7
|
Weber S, Jungilligens J, Aybek S, Popkirov S. Locus coeruleus co-activation patterns at rest show higher state persistence in patients with dissociative seizures: A Pilot Study. Epilepsia Open 2024; 9:2331-2341. [PMID: 39373074 PMCID: PMC11633765 DOI: 10.1002/epi4.13050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2024] [Revised: 08/04/2024] [Accepted: 09/12/2024] [Indexed: 10/08/2024] Open
Abstract
OBJECTIVE Dissociative seizures are paroxysmal disruptions of awareness and behavioral control in the context of affective arousal. Alterations in stress-related endocrine function have been demonstrated, but the timescale of dissociation suggests that the central locus coeruleus (LC) noradrenergic system is likely pivotal. Here, we investigate whether LC activation at rest is associated with altered brain network dynamics. METHODS A preliminary co-activation pattern (CAP) analysis of resting-state functional magnetic resonance imaging (fMRI) in 14 patients with dissociative seizures and 14 healthy controls was performed by using the LC as a seeding region. The red nucleus served as a control condition. Entry rates, durations, and state transition probabilities of identified CAPs were calculated. Analyses were corrected for demographic, technical, and clinical confounders including depression and anxiety. RESULTS Three LC-related CAPs were identified, with the dominant two showing inverse activations and deactivations of the default mode network and the attention networks, respectively. Analysis of transition probabilities between and within the three CAPs revealed higher state persistence in patients compared to healthy controls for both CAP2LC (Cohen's d = -0.55; p = 0.01) and CAP3LC (Cohen's d = -0.57; p = 0.01). The control analysis using the red nucleus as a seed yielded similar CAPs, but no significant between-group differences in transition probabilities. SIGNIFICANCE Higher state persistence of LC-CAPs in patients with dissociative seizures generates the novel hypothesis that arousal-related impairments of network switching might be a candidate neural mechanism of dissociation. PLAIN LANGUAGE SUMMARY Dissociative seizures often arise during high affective arousal. The locus coeruleus is a brain structure involved in managing such acute arousal states. We investigated whether the activity of the locus coeruleus correlates with activity in other regions of the brain (which we refer to as "brain states"), and whether those brain states were different between patients with dissociative seizures and healthy controls. We found that patients tended to stay in certain locus coeruleus-dependent brain states instead of switching between them. This might be related to the loss of awareness and disruptions of brain functions ("dissociation") that patients experience during seizures.
Collapse
Affiliation(s)
- Samantha Weber
- Department of Neurology, Psychosomatic Medicine UnitInselspital Bern University Hospital, University of BernBernSwitzerland
- Department of Psychiatry, Psychotherapy and PsychosomaticsUniversity of Zurich, Psychiatric University Hospital ZurichZurichSwitzerland
- Translational Imaging Center (TIC)Swiss Institute for Translational and Entrepreneurial MedicineBernSwitzerland
| | - Johannes Jungilligens
- Department of NeurologyUniversity Hospital Knappschaftskrankenhaus, Ruhr University BochumBochumGermany
| | - Selma Aybek
- Department of Neurology, Psychosomatic Medicine UnitInselspital Bern University Hospital, University of BernBernSwitzerland
- Faculty of Science and MedicineUniversity of FribourgFribourgSwitzerland
| | - Stoyan Popkirov
- Department of NeurologyUniversity Hospital EssenEssenGermany
| |
Collapse
|
8
|
Singh R, Singh N, Kaur L. Deep learning methods for 3D magnetic resonance image denoising, bias field and motion artifact correction: a comprehensive review. Phys Med Biol 2024; 69:23TR01. [PMID: 39569887 DOI: 10.1088/1361-6560/ad94c7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2024] [Accepted: 11/19/2024] [Indexed: 11/22/2024]
Abstract
Magnetic resonance imaging (MRI) provides detailed structural information of the internal body organs and soft tissue regions of a patient in clinical diagnosis for disease detection, localization, and progress monitoring. MRI scanner hardware manufacturers incorporate various post-acquisition image-processing techniques into the scanner's computer software tools for different post-processing tasks. These tools provide a final image of adequate quality and essential features for accurate clinical reporting and predictive interpretation for better treatment planning. Different post-acquisition image-processing tasks for MRI quality enhancement include noise removal, motion artifact reduction, magnetic bias field correction, and eddy electric current effect removal. Recently, deep learning (DL) methods have shown great success in many research fields, including image and video applications. DL-based data-driven feature-learning approaches have great potential for MR image denoising and image-quality-degrading artifact correction. Recent studies have demonstrated significant improvements in image-analysis tasks using DL-based convolutional neural network techniques. The promising capabilities and performance of DL techniques in various problem-solving domains have motivated researchers to adapt DL methods to medical image analysis and quality enhancement tasks. This paper presents a comprehensive review of DL-based state-of-the-art MRI quality enhancement and artifact removal methods for regenerating high-quality images while preserving essential anatomical and physiological feature maps without destroying important image information. Existing research gaps and future directions have also been provided by highlighting potential research areas for future developments, along with their importance and advantages in medical imaging.
Collapse
Affiliation(s)
- Ram Singh
- Department of Computer Science & Engineering, Punjabi University, Chandigarh Road, Patiala 147002, Punjab, India
| | - Navdeep Singh
- Department of Computer Science & Engineering, Punjabi University, Chandigarh Road, Patiala 147002, Punjab, India
| | - Lakhwinder Kaur
- Department of Computer Science & Engineering, Punjabi University, Chandigarh Road, Patiala 147002, Punjab, India
| |
Collapse
|
9
|
Ruijters L, Lund TE, Vinding MS. Improving B 1 + $$ {B}_1^{+} $$ -inhomogeneity tolerance by resolving non-bijection in MP2RAGE R 1 mapping: A 2D look-up table approach demonstrated at 3 T. Magn Reson Med 2024. [PMID: 39529499 DOI: 10.1002/mrm.30363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Revised: 10/10/2024] [Accepted: 10/15/2024] [Indexed: 11/16/2024]
Abstract
PURPOSE Regarding in vivo, robust longitudinal relaxation rate (R1) mapping, the goal of the present paper is two-fold. First, to verify that non-bijective mapping in magnetization-prepared 2 rapid gradient echo (MP2RAGE) imaging can be resolved through a two-dimensional look-up table approach. Second, that the expanded parameter space from this can be used to improveB 1 + $$ {B}_1^{+} $$ -inhomogeneity tolerance without other prerequisites. THEORY By deriving a second contrast from the magnitude images of the MP2RAGE acquisition, ambiguities in the original MP2RAGE image resulting from non-bijective transfer curves can be resolved. Such ambiguities may occur when protocols are optimized, such as for higherB 1 + $$ {B}_1^{+} $$ -inhomogeneity tolerance. A 2D look-up table approach combines the available information to resolve these ambiguities during mapping. METHODS At 3 T, we acquired MP2RAGE images with standard acquisition parameters and (non-bijective) parameters optimized forB 1 + $$ {B}_1^{+} $$ -inhomogeneity tolerance. From 3 subjects across multiple sessions, we assessed theB 1 + $$ {B}_1^{+} $$ -inhomogeneity tolerance through excitation-pulse amplitude scalings. RESULTS The R1 maps resulting from theB 1 + $$ {B}_1^{+} $$ -optimized protocols showed greatly reducedB 1 + $$ {B}_1^{+} $$ effects across images but without additional scanner time. Meanwhile, these maps could only successfully be derived by a 2D look-up table approach. CONCLUSION We show that it is possible to optimize forB 1 + $$ {B}_1^{+} $$ -inhomogeneity tolerance in MP2RAGE through sequence-parameter settings, while still successfully estimating the R1 map with a two-dimensional look-up table approach. This without the need for an additionalB 1 + $$ {B}_1^{+} $$ map. The increased parameter space enabled by the two-dimensional look-up table approach may further be used to adjust MP2RAGE acquisitions for improved scan times, signal-to-noise ratio, and/or contrast-to-noise ratio.
Collapse
Affiliation(s)
- Lenno Ruijters
- Center of Functionally Integrative Neuroscience, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Torben Ellegaard Lund
- Center of Functionally Integrative Neuroscience, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Mads Sloth Vinding
- Center of Functionally Integrative Neuroscience, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
10
|
Brackenier Y, Cordero-Grande L, McElroy S, Tomi-Tricot R, Barbaroux H, Bridgen P, Malik SJ, Hajnal JV. Sequence-agnostic motion-correction leveraging efficiently calibrated Pilot Tone signals. Magn Reson Med 2024; 92:1881-1897. [PMID: 38860530 DOI: 10.1002/mrm.30161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 04/18/2024] [Accepted: 05/07/2024] [Indexed: 06/12/2024]
Abstract
PURPOSE This study leverages externally generated Pilot Tone (PT) signals to perform motion-corrected brain MRI for sequences with arbitrary k-space sampling and image contrast. THEORY AND METHODS PT signals are promising external motion sensors due to their cost-effectiveness, easy workflow, and consistent performance across contrasts and sampling patterns. However, they lack robust calibration pipelines. This work calibrates PT signal to rigid motion parameters acquired during short blocks (˜4 s) of motion calibration (MC) acquisitions, which are short enough to unobstructively fit between acquisitions. MC acquisitions leverage self-navigated trajectories that enable state-of-the-art motion estimation methods for efficient calibration. To capture the range of patient motion occurring throughout the examination, distributed motion calibration (DMC) uses data acquired from MC scans distributed across the entire examination. After calibration, PT is used to retrospectively motion-correct sequences with arbitrary k-space sampling and image contrast. Additionally, a data-driven calibration refinement is proposed to tailor calibration models to individual acquisitions. In vivo experiments involving 12 healthy volunteers tested the DMC protocol's ability to robustly correct subject motion. RESULTS The proposed calibration pipeline produces pose parameters consistent with reference values, even when distributing only six of these approximately 4-s MC blocks, resulting in a total acquisition time of 22 s. In vivo motion experiments reveal significant (p < 0.05 $$ p<0.05 $$ ) improved motion correction with increased signal to residual ratio for both MPRAGE and SPACE sequences with standard k-space acquisition, especially when motion is large. Additionally, results highlight the benefits of using a distributed calibration approach. CONCLUSIONS This study presents a framework for performing motion-corrected brain MRI in sequences with arbitrary k-space encoding and contrast, using externally generated PT signals. The DMC protocol is introduced, promoting observation of patient motion occurring throughout the examination and providing a calibration pipeline suitable for clinical deployment. The method's application is demonstrated in standard volumetric MPRAGE and SPACE sequences.
Collapse
Affiliation(s)
- Yannick Brackenier
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Lucilio Cordero-Grande
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Biomedical Image Technologies, ETSI Telecomunicación, Universidad Politécnica de Madrid and CIBER-BNN, ISCIII, Madrid, Spain
| | - Sarah McElroy
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK
| | - Raphael Tomi-Tricot
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK
| | - Hugo Barbaroux
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Philippa Bridgen
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Shaihan J Malik
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Joseph V Hajnal
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| |
Collapse
|
11
|
Zhao B, Zhou Y, Zong X. Effects of prospective motion correction on perivascular spaces at 7T MRI evaluated using motion artifact simulation. Magn Reson Med 2024; 92:1079-1094. [PMID: 38651650 PMCID: PMC11209793 DOI: 10.1002/mrm.30126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 03/12/2024] [Accepted: 04/04/2024] [Indexed: 04/25/2024]
Abstract
PURPOSE The effectiveness of prospective motion correction (PMC) is often evaluated by comparing artifacts in images acquired with and without PMC (NoPMC). However, such an approach is not applicable in clinical setting due to unavailability of NoPMC images. We aim to develop a simulation approach for demonstrating the ability of fat-navigator-based PMC in improving perivascular space (PVS) visibility in T2-weighted MRI. METHODS MRI datasets from two earlier studies were used for motion artifact simulation and evaluating PMC, including T2-weighted NoPMC and PMC images. To simulate motion artifacts, k-space data at motion-perturbed positions were calculated from artifact-free images using nonuniform Fourier transform and misplaced onto the Cartesian grid before inverse Fourier transform. The simulation's ability to reproduce motion-induced blurring, ringing, and ghosting artifacts was evaluated using sharpness at lateral ventricle/white matter boundary, ringing artifact magnitude in the Fourier spectrum, and background noise, respectively. PVS volume fraction in white matter was employed to reflect its visibility. RESULTS In simulation, sharpness, PVS volume fraction, and background noise exhibited significant negative correlations with motion score. Significant correlations were found in sharpness, ringing artifact magnitude, and PVS volume fraction between simulated and real NoPMC images (p ≤ 0.006). In contrast, such correlations were reduced and nonsignificant between simulated and real PMC images (p ≥ 0.48), suggesting reduction of motion effects with PMC. CONCLUSIONS The proposed simulation approach is an effective tool to study the effects of motion and PMC on PVS visibility. PMC may reduce the systematic bias of PVS volume fraction caused by motion artifacts.
Collapse
Affiliation(s)
- Bingbing Zhao
- School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai 201210, China
| | - Yichen Zhou
- School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai 201210, China
| | - Xiaopeng Zong
- School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai 201210, China
| |
Collapse
|
12
|
Woods JG, Achten E, Asllani I, Bolar DS, Dai W, Detre JA, Fan AP, Fernández-Seara M, Golay X, Günther M, Guo J, Hernandez-Garcia L, Ho ML, Juttukonda MR, Lu H, MacIntosh BJ, Madhuranthakam AJ, Mutsaerts HJ, Okell TW, Parkes LM, Pinter N, Pinto J, Qin Q, Smits M, Suzuki Y, Thomas DL, Van Osch MJ, Wang DJJ, Warnert EA, Zaharchuk G, Zelaya F, Zhao M, Chappell MA. Recommendations for quantitative cerebral perfusion MRI using multi-timepoint arterial spin labeling: Acquisition, quantification, and clinical applications. Magn Reson Med 2024; 92:469-495. [PMID: 38594906 PMCID: PMC11142882 DOI: 10.1002/mrm.30091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 02/09/2024] [Accepted: 03/07/2024] [Indexed: 04/11/2024]
Abstract
Accurate assessment of cerebral perfusion is vital for understanding the hemodynamic processes involved in various neurological disorders and guiding clinical decision-making. This guidelines article provides a comprehensive overview of quantitative perfusion imaging of the brain using multi-timepoint arterial spin labeling (ASL), along with recommendations for its acquisition and quantification. A major benefit of acquiring ASL data with multiple label durations and/or post-labeling delays (PLDs) is being able to account for the effect of variable arterial transit time (ATT) on quantitative perfusion values and additionally visualize the spatial pattern of ATT itself, providing valuable clinical insights. Although multi-timepoint data can be acquired in the same scan time as single-PLD data with comparable perfusion measurement precision, its acquisition and postprocessing presents challenges beyond single-PLD ASL, impeding widespread adoption. Building upon the 2015 ASL consensus article, this work highlights the protocol distinctions specific to multi-timepoint ASL and provides robust recommendations for acquiring high-quality data. Additionally, we propose an extended quantification model based on the 2015 consensus model and discuss relevant postprocessing options to enhance the analysis of multi-timepoint ASL data. Furthermore, we review the potential clinical applications where multi-timepoint ASL is expected to offer significant benefits. This article is part of a series published by the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group, aiming to guide and inspire the advancement and utilization of ASL beyond the scope of the 2015 consensus article.
Collapse
Affiliation(s)
- Joseph G. Woods
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
- Center for Functional Magnetic Resonance Imaging, Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Eric Achten
- Ghent Institute for Functional and Metabolic Imaging (GIfMI), Ghent University, Ghent, Belgium
| | - Iris Asllani
- Department of Neuroscience, University of Sussex, UK and Department of Biomedical Engineering, Rochester Institute of Technology, USA
| | - Divya S. Bolar
- Center for Functional Magnetic Resonance Imaging, Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Weiying Dai
- Department of Computer Science, State University of New York at Binghamton, Binghamton, NY, USA, 13902
| | - John A. Detre
- Department of Neurology, University of Pennsylvania, 3 Dulles Building, 3400 Spruce Street, Philadelphia, PA 19104 USA
| | - Audrey P. Fan
- Department of Biomedical Engineering, Department of Neurology, University of California Davis, Davis, CA, USA
| | - Maria Fernández-Seara
- Department of Radiology, Clínica Universidad de Navarra, Pamplona, Spain; IdiSNA, Instituto de Investigación Sanitaria de Navarra, Pamplona, Spain
| | - Xavier Golay
- UCL Queen Square Institute of Neurology, University College London, London, UK; Gold Standard Phantoms, UK
| | - Matthias Günther
- Imaging Physics, Fraunhofer Institute for Digital Medicine MEVIS, Bremen, Germany
- Departments of Physics and Electrical Engineering, University of Bremen, Bremen, Germany
| | - Jia Guo
- Department of Bioengineering, University of California Riverside, Riverside, CA, USA
| | | | - Mai-Lan Ho
- Department of Radiology, University of Missouri, Columbia, MO, USA. ORCID: 0000-0002-9455-1350
| | - Meher R. Juttukonda
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Hanzhang Lu
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Bradley J. MacIntosh
- Hurvitz Brain Sciences Program, Centre for Brain Resilience & Recovery, Sunnybrook Research Institute, Toronto, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Canada
- Computational Radiology & Artificial Intelligence unit, Oslo University Hospital, Oslo, Norway
| | - Ananth J. Madhuranthakam
- Department of Radiology and Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA
| | - Henk-Jan Mutsaerts
- Amsterdam UMC location Vrije Universiteit Amsterdam, Department of Radiology and Nuclear Medicine, Amsterdam, The Netherlands
- Amsterdam Neuroscience, Brain Imaging, Amsterdam, The Netherlands
| | - Thomas W. Okell
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Laura M. Parkes
- School of Health Sciences, Faculty of Biology, Medicine and Health, University of Manchester, UK
- Geoffrey Jefferson Brain Research Centre, Manchester Academic Health Science Centre, UK
| | - Nandor Pinter
- Dent Neurologic Institute, Buffalo, New York, USA; University at Buffalo Neurosurgery, Buffalo, New York, USA
| | - Joana Pinto
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK
| | - Qin Qin
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Marion Smits
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
- Medical Delta, Delft, The Netherlands
- Erasmus MC Cancer Institute, Erasmus MC, Rotterdam, NL
| | - Yuriko Suzuki
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - David L. Thomas
- Department of Brain Repair and Rehabilitation, UCL Queen Square Institute of Neurology, University College London, London, UK
| | - Matthias J.P. Van Osch
- C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Danny JJ Wang
- Laboratory of FMRI Technology (LOFT), Stevens Neuroimaging and Informatics Institute, University of Southern California, Los Angeles, CA, USA
| | - Esther A.H. Warnert
- Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
- Erasmus MC Cancer Institute, Erasmus MC, Rotterdam, NL
| | - Greg Zaharchuk
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Fernando Zelaya
- Department of Neuroimaging, Institute of Psychiatry, Psychology and Neuroscience, Kings College London, London, UK
| | - Moss Zhao
- Department of Radiology, Stanford University, Stanford, CA, USA
- Maternal & Child Health Research Institute, Stanford University, Stanford, CA, USA
| | - Michael A. Chappell
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
- Sir Peter Mansfield Imaging Centre, School of Medicine, University of Nottingham, Nottingham, UK
| |
Collapse
|
13
|
Marchetto E, Gallichan D. Analysis of the effect of motion on highly accelerated 3D FatNavs in 3D brain images acquired at 3T. PLoS One 2024; 19:e0306078. [PMID: 39052654 PMCID: PMC11271950 DOI: 10.1371/journal.pone.0306078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 06/11/2024] [Indexed: 07/27/2024] Open
Abstract
PURPOSE 3D FatNavs are rapid acquisitions of MRI fat-volumes within the head that can be used for retrospective motion correction for brain MRI. 3D FatNavs typically use very high acceleration factors and are reconstructed with the GRAPPA parallel imaging technique. However, the GRAPPA reconstruction is not expected to perform well on 3D FatNavs volumes in the presence of strong motion due to the mismatched calibration data acquired once at the start of the scan, leading to motion-parameter misestimation. This study aims to assess the accuracy and precision of 3D FatNav-derived motion-estimates in the presence of large changes in head position. METHODS Rigid motion parameters were simulated and applied retrospectively to the 3D FatNav volumes from MPRAGE datasets acquired at 3T. The transformed images were then re-reconstructed using GRAPPA to simulate real motion deterioration of the fat-navigator, and used to estimate the motion applied and evaluate the tracking inaccuracy. This information was then used to estimate the residual motion after 3D FatNav-based motion correction and applied to the original MPRAGE volumes. The effect of the misestimation was assessed using an image quality metric and the evaluation scores from two observers. Quality boundaries were then estimated to assess the motion tolerance when 3D FatNavs are used. RESULTS The GRAPPA reconstruction was shown to deteriorate for large changes in the head position, affecting the quality of 3D FatNav volumes and consequently degrading the accuracy of the motion-estimates. Based on our simulations, the estimated threshold of motion that led to a noticeable degradation in the MPRAGE image quality was up to RMS values of 3.7° and 3 mm for rotations and translations respectively. CONCLUSIONS 3D FatNavs were shown to be able to correct for a wide range of motion levels and types. Boundaries of acceptable motion magnitudes for different levels of acceptable loss of image quality were determined.
Collapse
Affiliation(s)
- Elisa Marchetto
- CUBRIC/School of Engineering, Cardiff University, Cardiff, United Kingdom
- Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, United States of America
- Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, United States of America
| | - Daniel Gallichan
- CUBRIC/School of Engineering, Cardiff University, Cardiff, United Kingdom
| |
Collapse
|
14
|
Hoffmann M, Hoopes A, Greve DN, Fischl B, Dalca AV. Anatomy-aware and acquisition-agnostic joint registration with SynthMorph. IMAGING NEUROSCIENCE (CAMBRIDGE, MASS.) 2024; 2:1-33. [PMID: 39015335 PMCID: PMC11247402 DOI: 10.1162/imag_a_00197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 04/27/2024] [Accepted: 05/21/2024] [Indexed: 07/18/2024]
Abstract
Affine image registration is a cornerstone of medical-image analysis. While classical algorithms can achieve excellent accuracy, they solve a time-consuming optimization for every image pair. Deep-learning (DL) methods learn a function that maps an image pair to an output transform. Evaluating the function is fast, but capturing large transforms can be challenging, and networks tend to struggle if a test-image characteristic shifts from the training domain, such as the resolution. Most affine methods are agnostic to the anatomy the user wishes to align, meaning the registration will be inaccurate if algorithms consider all structures in the image. We address these shortcomings with SynthMorph, a fast, symmetric, diffeomorphic, and easy-to-use DL tool for joint affine-deformable registration of any brain image without preprocessing. First, we leverage a strategy that trains networks with widely varying images synthesized from label maps, yielding robust performance across acquisition specifics unseen at training. Second, we optimize the spatial overlap of select anatomical labels. This enables networks to distinguish anatomy of interest from irrelevant structures, removing the need for preprocessing that excludes content which would impinge on anatomy-specific registration. Third, we combine the affine model with a deformable hypernetwork that lets users choose the optimal deformation-field regularity for their specific data, at registration time, in a fraction of the time required by classical methods. This framework is applicable to learning anatomy-aware, acquisition-agnostic registration of any anatomy with any architecture, as long as label maps are available for training. We analyze how competing architectures learn affine transforms and compare state-of-the-art registration tools across an extremely diverse set of neuroimaging data, aiming to truly capture the behavior of methods in the real world. SynthMorph demonstrates high accuracy and is available at https://w3id.org/synthmorph, as a single complete end-to-end solution for registration of brain magnetic resonance imaging (MRI) data.
Collapse
Affiliation(s)
- Malte Hoffmann
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA, United States
- Department of Radiology, Massachusetts General Hospital, Boston, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
| | - Andrew Hoopes
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA, United States
- Department of Radiology, Massachusetts General Hospital, Boston, MA, United States
- Computer Science & Artificial Intelligence Laboratory, Massachusetts Institute of Technology, Cambridge, MA, United States
| | - Douglas N. Greve
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA, United States
- Department of Radiology, Massachusetts General Hospital, Boston, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
| | - Bruce Fischl
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA, United States
- Department of Radiology, Massachusetts General Hospital, Boston, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
- Computer Science & Artificial Intelligence Laboratory, Massachusetts Institute of Technology, Cambridge, MA, United States
| | - Adrian V. Dalca
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA, United States
- Department of Radiology, Massachusetts General Hospital, Boston, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
- Computer Science & Artificial Intelligence Laboratory, Massachusetts Institute of Technology, Cambridge, MA, United States
| |
Collapse
|
15
|
Hossain MB, Shinde RK, Imtiaz SM, Hossain FMF, Jeon SH, Kwon KC, Kim N. Swin Transformer and the Unet Architecture to Correct Motion Artifacts in Magnetic Resonance Image Reconstruction. Int J Biomed Imaging 2024; 2024:8972980. [PMID: 38725808 PMCID: PMC11081754 DOI: 10.1155/2024/8972980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 04/08/2024] [Accepted: 04/23/2024] [Indexed: 05/12/2024] Open
Abstract
We present a deep learning-based method that corrects motion artifacts and thus accelerates data acquisition and reconstruction of magnetic resonance images. The novel model, the Motion Artifact Correction by Swin Network (MACS-Net), uses a Swin transformer layer as the fundamental block and the Unet architecture as the neural network backbone. We employ a hierarchical transformer with shifted windows to extract multiscale contextual features during encoding. A new dual upsampling technique is employed to enhance the spatial resolutions of feature maps in the Swin transformer-based decoder layer. A raw magnetic resonance imaging dataset is used for network training and testing; the data contain various motion artifacts with ground truth images of the same subjects. The results were compared to six state-of-the-art MRI image motion correction methods using two types of motions. When motions were brief (within 5 s), the method reduced the average normalized root mean square error (NRMSE) from 45.25% to 17.51%, increased the mean structural similarity index measure (SSIM) from 79.43% to 91.72%, and increased the peak signal-to-noise ratio (PSNR) from 18.24 to 26.57 dB. Similarly, when motions were extended from 5 to 10 s, our approach decreased the average NRMSE from 60.30% to 21.04%, improved the mean SSIM from 33.86% to 90.33%, and increased the PSNR from 15.64 to 24.99 dB. The anatomical structures of the corrected images and the motion-free brain data were similar.
Collapse
Affiliation(s)
- Md. Biddut Hossain
- Department of Information and Communication Engineering, Chungbuk National University, Cheongju-si 28644, Chungcheongbuk-do, Republic of Korea
| | - Rupali Kiran Shinde
- Department of Information and Communication Engineering, Chungbuk National University, Cheongju-si 28644, Chungcheongbuk-do, Republic of Korea
| | - Shariar Md Imtiaz
- Department of Information and Communication Engineering, Chungbuk National University, Cheongju-si 28644, Chungcheongbuk-do, Republic of Korea
| | - F. M. Fahmid Hossain
- Department of Information and Communication Engineering, Chungbuk National University, Cheongju-si 28644, Chungcheongbuk-do, Republic of Korea
| | - Seok-Hee Jeon
- Department of Electronics Engineering, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon 22012, Republic of Korea
| | - Ki-Chul Kwon
- Department of Information and Communication Engineering, Chungbuk National University, Cheongju-si 28644, Chungcheongbuk-do, Republic of Korea
| | - Nam Kim
- Department of Information and Communication Engineering, Chungbuk National University, Cheongju-si 28644, Chungcheongbuk-do, Republic of Korea
| |
Collapse
|
16
|
Ulrich T, Riedel M, Pruessmann KP. Servo navigators: Linear regression and feedback control for rigid-body motion correction. Magn Reson Med 2024; 91:1876-1892. [PMID: 38234052 DOI: 10.1002/mrm.29967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 11/05/2023] [Accepted: 11/24/2023] [Indexed: 01/19/2024]
Abstract
PURPOSE Navigator-based correction of rigid-body motion reconciling high precision with minimal acquisition, minimal calibration and simple, fast processing. METHODS A short orbital navigator (2.3 ms) is inserted in a three-dimensional (3D) gradient echo sequence for human head imaging. Head rotation and translation are determined by linear regression based on a complex-valued model built either from three reference navigators or in a reference-less fashion, from the first actual navigator. Optionally, the model is expanded by global phase and field offset. Run-time scan correction on this basis establishes servo control that maintains validity of the linear picture by keeping its expansion point stable in the head frame of reference. The technique is assessed in a phantom and demonstrated by motion-corrected imaging in vivo. RESULTS The proposed approach is found to establish stable motion control both with and without reference acquisition. In a phantom, it is shown to accurately detect motion mimicked by rotation of scan geometry as well as change in global B0 . It is demonstrated to converge to accurate motion estimates after perturbation well beyond the linear signal range. In vivo, servo navigation achieved motion detection with precision in the single-digit range of micrometers and millidegrees. Involuntary and intentional motion in the range of several millimeters were successfully corrected, achieving excellent image quality. CONCLUSION The combination of linear regression and feedback control enables prospective motion correction for head imaging with high precision and accuracy, short navigator readouts, fast run-time computation, and minimal demand for reference data.
Collapse
Affiliation(s)
- Thomas Ulrich
- Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland
| | - Malte Riedel
- Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland
| | - Klaas P Pruessmann
- Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland
| |
Collapse
|
17
|
Brackenier Y, Wang N, Liao C, Cao X, Schauman S, Yurt M, Cordero-Grande L, Malik SJ, Kerr A, Hajnal JV, Setsompop K. Rapid and accurate navigators for motion and B 0 tracking using QUEEN: Quantitatively enhanced parameter estimation from navigators. Magn Reson Med 2024; 91:2028-2043. [PMID: 38173304 DOI: 10.1002/mrm.29976] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2023] [Revised: 11/28/2023] [Accepted: 11/29/2023] [Indexed: 01/05/2024]
Abstract
PURPOSE To develop a framework that jointly estimates rigid motion and polarizing magnetic field (B0 ) perturbations (δ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ ) for brain MRI using a single navigator of a few milliseconds in duration, and to additionally allow for navigator acquisition at arbitrary timings within any type of sequence to obtain high-temporal resolution estimates. THEORY AND METHODS Methods exist that match navigator data to a low-resolution single-contrast image (scout) to estimate either motion orδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ . In this work, called QUEEN (QUantitatively Enhanced parameter Estimation from Navigators), we propose combined motion andδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ estimation from a fast, tailored trajectory with arbitrary-contrast navigator data. To this end, the concept of a quantitative scout (Q-Scout) acquisition is proposed from which contrast-matched scout data is predicted for each navigator. Finally, navigator trajectories, contrast-matched scout, andδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ are integrated into a motion-informed parallel-imaging framework. RESULTS Simulations and in vivo experiments show the need to modelδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ to obtain accurate motion parameters estimated in the presence of strongδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ . Simulations confirm that tailored navigator trajectories are needed to robustly estimate both motion andδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ . Furthermore, experiments show that a contrast-matched scout is needed for parameter estimation from multicontrast navigator data. A retrospective, in vivo reconstruction experiment shows improved image quality when using the proposed Q-Scout and QUEEN estimation. CONCLUSIONS We developed a framework to jointly estimate rigid motion parameters andδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ from navigators. Combing a contrast-matched scout with the proposed trajectory allows for navigator deployment in almost any sequence and/or timing, which allows for higher temporal-resolution motion andδ B 0 $$ \delta {\mathbf{B}}_{\mathbf{0}} $$ estimates.
Collapse
Affiliation(s)
| | - Nan Wang
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Congyu Liao
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Xiaozhi Cao
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Sophie Schauman
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Mahmut Yurt
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Lucilio Cordero-Grande
- Biomedical Image Technologies, ETSI Telecomunicación, Universidad Politécnica de Madrid and CIBER-BNN, Madrid, Spain
| | - Shaihan J Malik
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Adam Kerr
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
- Cognitive and Neurobiological Imaging, Stanford University, Stanford, California, USA
| | - Joseph V Hajnal
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Kawin Setsompop
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| |
Collapse
|
18
|
Wallace TE, Piccini D, Kober T, Warfield SK, Afacan O. Rapid motion estimation and correction using self-encoded FID navigators in 3D radial MRI. Magn Reson Med 2024; 91:1057-1066. [PMID: 37929608 PMCID: PMC10843402 DOI: 10.1002/mrm.29899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 09/15/2023] [Accepted: 10/06/2023] [Indexed: 11/07/2023]
Abstract
PURPOSE To develop a self-navigated motion compensation strategy for 3D radial MRI that can compensate for continuous head motion by measuring rigid body motion parameters with high temporal resolution from the central k-space acquisition point (self-encoded FID navigator) in each radial spoke. METHODS A forward model was created from low-resolution calibration data to simulate the effect of relative motion between the coil sensitivity profiles and the underlying object on the self-encoded FID navigator signal. Trajectory deviations were included in the model as low spatial-order field variations. Three volunteers were imaged at 3 T using a modified 3D gradient-echo sequence acquired with a Kooshball trajectory while performing abrupt and continuous head motion. Rigid body-motion parameters were estimated from the central k-space signal of each spoke using a least-squares fitting algorithm. The accuracy of self-navigated motion parameters was assessed relative to an established external tracking system. Quantitative image quality metrics were computed for images with and without retrospective correction using external and self-navigated motion measurements. RESULTS Self-encoded FID navigators achieved mean absolute errors of 0.69 ± 0.82 mm and 0.73 ± 0.87° relative to external tracking for maximum motion amplitudes of 12 mm and 10°. Retrospective correction of the 3D radial data resulted in substantially improved image quality for both abrupt and continuous motion paradigms, comparable to external tracking results. CONCLUSIONS Accurate rigid body motion parameters can be rapidly obtained from self-encoded FID navigator signals in 3D radial MRI to continuously correct for head movements. This approach is suitable for robust neuroanatomical imaging in subjects that exhibit patterns of large and frequent motion.
Collapse
Affiliation(s)
| | - Davide Piccini
- Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland
- Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Tobias Kober
- Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland
- Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Simon K. Warfield
- Department of Radiology, Boston Children’s Hospital, Boston, MA, USA
- Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Onur Afacan
- Department of Radiology, Boston Children’s Hospital, Boston, MA, USA
- Department of Radiology, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
19
|
Weber S, Bühler J, Loukas S, Bolton TAW, Vanini G, Bruckmaier R, Aybek S. Transient resting-state salience-limbic co-activation patterns in functional neurological disorders. Neuroimage Clin 2024; 41:103583. [PMID: 38422831 PMCID: PMC10944183 DOI: 10.1016/j.nicl.2024.103583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 02/09/2024] [Accepted: 02/25/2024] [Indexed: 03/02/2024]
Abstract
BACKGROUND Functional neurological disorders were historically regarded as the manifestation of a dynamic brain lesion which might be linked to trauma or stress, although this association has not yet been directly tested yet. Analysing large-scale brain network dynamics at rest in relation to stress biomarkers assessed by salivary cortisol and amylase could provide new insights into the pathophysiology of functional neurological symptoms. METHODS Case-control resting-state functional magnetic resonance imaging study of 79 patients with mixed functional neurological disorders (i.e., functional movement disorders, functional seizures, persistent perceptual-postural dizziness) and 74 age- and sex-matched healthy controls. Using a two-step hierarchical data-driven neuroimaging approach, static functional connectivity was first computed between 17 resting-state networks. Second, dynamic alterations in these networks were examined using co-activation pattern analysis. Using a partial least squares correlation analysis, the multivariate pattern of correlation between altered temporal characteristics and stress biomarkers as well as clinical scores were evaluated. RESULTS Compared to healthy controls, patients presented with functional aberrancies of the salience-limbic network connectivity. Thus, the insula and amygdala were selected as seed-regions for the subsequent analyses. Insular co-(de)activation patterns related to the salience network, the somatomotor network and the default mode network were detected, which patients entered more frequently than controls. Moreover, an insular co-(de)activation pattern with subcortical regions together with a wide-spread co-(de)activation with diverse cortical networks was detected, which patients entered less frequently than controls. In patients, dynamic alterations conjointly correlated with amylase measures and duration of symptoms. CONCLUSION The relationship between alterations in insular co-activation patterns, stress biomarkers and clinical data proposes inter-related mechanisms involved in stress regulation and functional (network) integration. In summary, altered functional brain network dynamics were identified in patients with functional neurological disorder supporting previously raised concepts of impaired attentional and interoceptive processing.
Collapse
Affiliation(s)
- Samantha Weber
- Department of Neurology, Psychosomatic Medicine Unit, Inselspital Bern University Hospital, University of Bern, 3012 Bern, Switzerland; University of Zurich, Psychiatric University Hospital Zurich, Department of Psychiatry, Psychotherapy and Psychosomatics, 8032 Zurich, Switzerland; Translational Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, 3010 Bern, Switzerland; Institute of Bioengineering, Ecole Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland.
| | - Janine Bühler
- Department of Neurology, Psychosomatic Medicine Unit, Inselspital Bern University Hospital, University of Bern, 3012 Bern, Switzerland; Translational Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, 3010 Bern, Switzerland
| | - Serafeim Loukas
- Department of Neurology, Psychosomatic Medicine Unit, Inselspital Bern University Hospital, University of Bern, 3012 Bern, Switzerland; Institute of Bioengineering, Ecole Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland; Division of Development and Growth, Department of Pediatrics, University of Geneva, 1211 Geneva, Switzerland
| | - Thomas A W Bolton
- Department of Clinical Neurosciences, Neurosurgery Service and Gamma Knife Center, Centre Hospitalier Universitaire Vaudois, 1011 Lausanne, Switzerland; Department of Radiology, Centre Hospitalier Universitaire Vaudois, 1011 Lausanne, Switzerland
| | - Giorgio Vanini
- Department of Neurology, Psychosomatic Medicine Unit, Inselspital Bern University Hospital, University of Bern, 3012 Bern, Switzerland
| | - Rupert Bruckmaier
- Veterinary Physiology, Vetsuisse Faculty, University of Bern, 3012 Bern, Switzerland
| | - Selma Aybek
- Department of Neurology, Psychosomatic Medicine Unit, Inselspital Bern University Hospital, University of Bern, 3012 Bern, Switzerland; Faculty of Science and Medicine, University of Fribourg, 1700 Fribourg, Switzerland
| |
Collapse
|
20
|
Qu G, Lu B, Shi J, Wang Z, Yuan Y, Xia Y, Pan Z, Lin Y. Motion-artifact-augmented pseudo-label network for semi-supervised brain tumor segmentation. Phys Med Biol 2024; 69:055023. [PMID: 38406849 DOI: 10.1088/1361-6560/ad2634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Accepted: 02/05/2024] [Indexed: 02/27/2024]
Abstract
MRI image segmentation is widely used in clinical practice as a prerequisite and a key for diagnosing brain tumors. The quest for an accurate automated segmentation method for brain tumor images, aiming to ease clinical doctors' workload, has gained significant attention as a research focal point. Despite the success of fully supervised methods in brain tumor segmentation, challenges remain. Due to the high cost involved in annotating medical images, the dataset available for training fully supervised methods is very limited. Additionally, medical images are prone to noise and motion artifacts, negatively impacting quality. In this work, we propose MAPSS, a motion-artifact-augmented pseudo-label network for semi-supervised segmentation. Our method combines motion artifact data augmentation with the pseudo-label semi-supervised training framework. We conduct several experiments under different semi-supervised settings on a publicly available dataset BraTS2020 for brain tumor segmentation. The experimental results show that MAPSS achieves accurate brain tumor segmentation with only a small amount of labeled data and maintains robustness in motion-artifact-influenced images. We also assess the generalization performance of MAPSS using the Left Atrium dataset. Our algorithm is of great significance for assisting doctors in formulating treatment plans and improving treatment quality.
Collapse
Affiliation(s)
- Guangcan Qu
- School of the 1st Clinical Medical Sciences (School of Information and Engineering), Wenzhou Medical University, Wenzhou 325000, People's Republic of China
| | - Beichen Lu
- School of the 1st Clinical Medical Sciences (School of Information and Engineering), Wenzhou Medical University, Wenzhou 325000, People's Republic of China
| | - Jialin Shi
- School of the 1st Clinical Medical Sciences (School of Information and Engineering), Wenzhou Medical University, Wenzhou 325000, People's Republic of China
| | - Ziyi Wang
- School of the 1st Clinical Medical Sciences (School of Information and Engineering), Wenzhou Medical University, Wenzhou 325000, People's Republic of China
| | - Yaping Yuan
- School of the 1st Clinical Medical Sciences (School of Information and Engineering), Wenzhou Medical University, Wenzhou 325000, People's Republic of China
| | - Yifan Xia
- School of the 1st Clinical Medical Sciences (School of Information and Engineering), Wenzhou Medical University, Wenzhou 325000, People's Republic of China
| | - Zhifang Pan
- School of the 1st Clinical Medical Sciences (School of Information and Engineering), Wenzhou Medical University, Wenzhou 325000, People's Republic of China
| | - Yezhi Lin
- School of the 1st Clinical Medical Sciences (School of Information and Engineering), Wenzhou Medical University, Wenzhou 325000, People's Republic of China
| |
Collapse
|
21
|
Li B, Li N, Wang Z, Balan R, Ernst T. Simultaneous multislice EPI prospective motion correction by real-time receiver phase correction and coil sensitivity map interpolation. Magn Reson Med 2023; 90:1932-1948. [PMID: 37448116 PMCID: PMC10795703 DOI: 10.1002/mrm.29789] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 06/13/2023] [Accepted: 06/16/2023] [Indexed: 07/15/2023]
Abstract
PURPOSE To improve the image reconstruction for prospective motion correction (PMC) of simultaneous multislice (SMS) EPI of the brain, an update of receiver phase and resampling of coil sensitivities are proposed and evaluated. METHODS A camera-based system was used to track head motion (3 translations and 3 rotations) and dynamically update the scan position and orientation. We derived the change in receiver phase associated with a shifted field of view (FOV) and applied it in real-time to each k-space line of the EPI readout trains. Second, for the SMS reconstruction, we adapted resampled coil sensitivity profiles reflecting the movement of slices. Single-shot gradient-echo SMS-EPI scans were performed in phantoms and human subjects for validation. RESULTS Brain SMS-EPI scans in the presence of motion with PMC and no phase correction for scan plane shift showed noticeable artifacts. These artifacts were visually and quantitatively attenuated when corrections were enabled. Correcting misaligned coil sensitivity maps improved the temporal SNR (tSNR) of time series by 24% (p = 0.0007) for scans with large movements (up to ˜35 mm and 30°). Correcting the receiver phase improved the tSNR of a scan with minimal head movement by 50% from 50 to 75 for a United Kingdom biobank protocol. CONCLUSION Reconstruction-induced motion artifacts in single-shot SMS-EPI scans acquired with PMC can be removed by dynamically adjusting the receiver phase of each line across EPI readout trains and updating coil sensitivity profiles during reconstruction. The method may be a valuable tool for SMS-EPI scans in the presence of subject motion.
Collapse
Affiliation(s)
- Bo Li
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland, Baltimore, MD, United States
| | - Ningzhi Li
- U.S. Food Drug Administration, Silver Spring, MD, United States
| | - Ze Wang
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland, Baltimore, MD, United States
| | - Radu Balan
- Department of Mathematics, University of Maryland, College Park, MD, United States
| | - Thomas Ernst
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland, Baltimore, MD, United States
| |
Collapse
|
22
|
Hu S, Chen Y, Zong X, Lin W, Griswold M, Ma D. Improving motion robustness of 3D MR fingerprinting with a fat navigator. Magn Reson Med 2023; 90:1802-1817. [PMID: 37345703 PMCID: PMC10524525 DOI: 10.1002/mrm.29761] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 05/01/2023] [Accepted: 05/26/2023] [Indexed: 06/23/2023]
Abstract
PURPOSE To develop a 3D MR fingerprinting (MRF) method in combination with fat navigators to improve its motion robustness for neuroimaging. METHODS A rapid fat navigator was developed using the stack-of-spirals acquisition and non-Cartesian spiral GRAPPA. The fat navigator module was implemented in the 3D MRF sequence with high scan efficiency. The developed method was first validated in phantoms and five healthy subjects with intentional head motion. The method was further applied to infants with neonatal opioid withdrawal symptoms. The 3D MRF scans with fat navigators acquired with and without acceleration along the partition-encoding direction were both examined in the study. RESULTS Both phantom and in vivo results demonstrated that the added fat navigator modules did not influence the quantification accuracy in MRF. In combination with non-Cartesian spiral GRAPPA, a rapid fat navigator sampling with whole-brain coverage was achieved in ˜0.5 s at 3T, reducing its sensitivity to potential motion. Based on the motion waveforms extracted from fat navigators, the motion robustness of the 3D MRF was largely improved. With the proposed method, the motion-corrupted MRF datasets yielded T1 and T2 maps with significantly reduced artifacts and high correlations with measurements from the reference motion-free MRF scans. CONCLUSION We developed a 3D MRF method coupled with rapid fat navigators to improve its motion robustness for quantitative neuroimaging. Our results demonstrate that (1) accurate tissue quantification was preserved with the fat navigator modules and (2) the motion robustness for quantitative tissue mapping was largely improved with the developed method.
Collapse
Affiliation(s)
- Siyuan Hu
- Department of Biomedical Engineering Cleveland, Ohio, USA
| | - Yong Chen
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Xiaopeng Zong
- School of Biomedical Engineering, ShanghaiTech University, Shanghai, China
| | - Weili Lin
- Department of Radiology, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Mark Griswold
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Dan Ma
- Department of Biomedical Engineering Cleveland, Ohio, USA
| |
Collapse
|
23
|
Marchetto E, Murphy K, Glimberg SL, Gallichan D. Robust retrospective motion correction of head motion using navigator-based and markerless motion tracking techniques. Magn Reson Med 2023; 90:1297-1315. [PMID: 37183791 PMCID: PMC7615144 DOI: 10.1002/mrm.29705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 04/05/2023] [Accepted: 04/26/2023] [Indexed: 05/16/2023]
Abstract
PURPOSE This study investigated the artifacts arising from different types of head motion in brain MR images and how well these artifacts can be compensated using retrospective correction based on two different motion-tracking techniques. METHODS MPRAGE images were acquired using a 3 T MR scanner on a cohort of nine healthy participants. Subjects moved their head to generate circular motion (4 or 6 cycles/min), stepwise motion (small and large) and "simulated realistic" motion (nodding and slow diagonal motion), based on visual instructions. One MPRAGE scan without deliberate motion was always acquired as a "no motion" reference. Three dimensional fat-navigator (FatNavs) and a Tracoline markerless device (TracInnovations) were used to obtain motion estimates and images were separately reconstructed retrospectively from the raw data based on these different motion estimates. RESULTS Image quality was recovered from both motion tracking techniques in our stepwise and slow diagonal motion scenarios in almost all cases, with the apparent visual image quality comparable to the no-motion case. FatNav-based motion correction was further improved in the case of stepwise motion using a skull masking procedure to exclude non-rigid motion of the neck from the co-registration step. In the case of circular motion, both methods struggled to correct for all motion artifacts. CONCLUSION High image quality could be recovered in cases of stepwise and slow diagonal motion using both motion estimation techniques. The circular motion scenario led to more severe image artifacts that could not be fully compensated by the retrospective motion correction techniques used.
Collapse
Affiliation(s)
- Elisa Marchetto
- CUBRIC/School of Engineering, Cardiff University, Cardiff, UK
| | - Kevin Murphy
- CUBRIC/School of Physics and Astronomy, Cardiff University, Cardiff, UK
| | | | | |
Collapse
|
24
|
Polak D, Hossbach J, Splitthoff DN, Clifford B, Lo WC, Tabari A, Lang M, Huang SY, Conklin J, Wald LL, Cauley S. Motion guidance lines for robust data consistency-based retrospective motion correction in 2D and 3D MRI. Magn Reson Med 2023; 89:1777-1790. [PMID: 36744619 PMCID: PMC10518424 DOI: 10.1002/mrm.29534] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 10/06/2022] [Accepted: 10/31/2022] [Indexed: 02/07/2023]
Abstract
PURPOSE To develop a robust retrospective motion-correction technique based on repeating k-space guidance lines for improving motion correction in Cartesian 2D and 3D brain MRI. METHODS The motion guidance lines are inserted into the standard sequence orderings for 2D turbo spin echo and 3D MPRAGE to inform a data consistency-based motion estimation and reconstruction, which can be guided by a low-resolution scout. The extremely limited number of required guidance lines are repeated during each echo train and discarded in the final image reconstruction. Thus, integration within a standard k-space acquisition ordering ensures the expected image quality/contrast and motion sensitivity of that sequence. RESULTS Through simulation and in vivo 2D multislice and 3D motion experiments, we demonstrate that respectively 2 or 4 optimized motion guidance lines per shot enables accurate motion estimation and correction. Clinically acceptable reconstruction times are achieved through fully separable on-the-fly motion optimizations (˜1 s/shot) using standard scanner GPU hardware. CONCLUSION The addition of guidance lines to scout accelerated motion estimation facilitates robust retrospective motion correction that can be effectively introduced without perturbing standard clinical protocols and workflows.
Collapse
Affiliation(s)
- Daniel Polak
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Siemens Healthcare GmbH, Erlangen, Germany
| | | | | | | | | | - Azadeh Tabari
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Min Lang
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Susie Y. Huang
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
- Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - John Conklin
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Lawrence L. Wald
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
- Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Stephen Cauley
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
25
|
Jäschke D, Steiner KM, Chang DI, Claaßen J, Uslar E, Thieme A, Gerwig M, Pfaffenrot V, Hulst T, Gussew A, Maderwald S, Göricke SL, Minnerop M, Ladd ME, Reichenbach JR, Timmann D, Deistung A. Age-related differences of cerebellar cortex and nuclei: MRI findings in healthy controls and its application to spinocerebellar ataxia (SCA6) patients. Neuroimage 2023; 270:119950. [PMID: 36822250 DOI: 10.1016/j.neuroimage.2023.119950] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 02/06/2023] [Accepted: 02/15/2023] [Indexed: 02/24/2023] Open
Abstract
Understanding cerebellar alterations due to healthy aging provides a reference point against which pathological findings in late-onset disease, for example spinocerebellar ataxia type 6 (SCA6), can be contrasted. In the present study, we investigated the impact of aging on the cerebellar nuclei and cerebellar cortex in 109 healthy controls (age range: 16 - 78 years) using 3 Tesla magnetic resonance imaging (MRI). Findings were compared with 25 SCA6 patients (age range: 38 - 78 years). A subset of 16 SCA6 (included: 14) patients and 50 controls (included: 45) received an additional MRI scan at 7 Tesla and were re-scanned after one year. MRI included T1-weighted, T2-weighted FLAIR, and multi-echo T2*-weighted imaging. The T2*-weighted phase images were converted to quantitative susceptibility maps (QSM). Since the cerebellar nuclei are characterized by elevated iron content with respect to their surroundings, two independent raters manually outlined them on the susceptibility maps. T1-weighted images acquired at 3T were utilized to automatically identify the cerebellar gray matter (GM) volume. Linear correlations revealed significant atrophy of the cerebellum due to tissue loss of cerebellar cortical GM in healthy controls with increasing age. Reduction of the cerebellar GM was substantially stronger in SCA6 patients. The volume of the dentate nuclei did not exhibit a significant relationship with age, at least in the age range between 18 and 78 years, whereas mean susceptibilities of the dentate nuclei increased with age. As previously shown, the dentate nuclei volumes were smaller and magnetic susceptibilities were lower in SCA6 patients compared to age- and sex-matched controls. The significant dentate volume loss in SCA6 patients could also be confirmed with 7T MRI. Linear mixed effects models and individual paired t-tests accounting for multiple comparisons revealed no statistical significant change in volume and susceptibility of the dentate nuclei after one year in neither patients nor controls. Importantly, dentate volumes were more sensitive to differentiate between SCA6 (Cohen's d = 3.02) and matched controls than the cerebellar cortex volume (d = 2.04). In addition to age-related decline of the cerebellar cortex and atrophy in SCA6 patients, age-related increase of susceptibility of the dentate nuclei was found in controls, whereas dentate volume and susceptibility was significantly decreased in SCA6 patients. Because no significant changes of any of these parameters was found at follow-up, these measures do not allow to monitor disease progression at short intervals.
Collapse
Affiliation(s)
- Dominik Jäschke
- Department of Neurology and Center for Translational Neuro- and Behavioral Sciences (C-TNBS), Essen University Hospital, University of Duisburg-Essen, Essen 45147, Germany; Department of Radiology and Nuclear Medicine, University Hospital Basel, Basel 4031, Switzerland
| | - Katharina M Steiner
- Department of Neurology and Center for Translational Neuro- and Behavioral Sciences (C-TNBS), Essen University Hospital, University of Duisburg-Essen, Essen 45147, Germany; LVR-Hospital Essen, Department of Psychiatry and Psychotherapy, Medical Faculty, University of Duisburg-Essen, Essen 45147, Germany
| | - Dae-In Chang
- Department of Neurology and Center for Translational Neuro- and Behavioral Sciences (C-TNBS), Essen University Hospital, University of Duisburg-Essen, Essen 45147, Germany; Clinic for Psychiatry, Psychotherapy and Preventive Medicine, LWL-University Hospital of the Ruhr-University Bochum, Bochum 44791, Germany
| | - Jens Claaßen
- Department of Neurology and Center for Translational Neuro- and Behavioral Sciences (C-TNBS), Essen University Hospital, University of Duisburg-Essen, Essen 45147, Germany; Fachklinik für Neurologie, MEDICLIN Klinik Reichshof, Reichshof-Eckenhagen 51580, Germany
| | - Ellen Uslar
- Department of Neurology and Center for Translational Neuro- and Behavioral Sciences (C-TNBS), Essen University Hospital, University of Duisburg-Essen, Essen 45147, Germany
| | - Andreas Thieme
- Department of Neurology and Center for Translational Neuro- and Behavioral Sciences (C-TNBS), Essen University Hospital, University of Duisburg-Essen, Essen 45147, Germany
| | - Marcus Gerwig
- Department of Neurology and Center for Translational Neuro- and Behavioral Sciences (C-TNBS), Essen University Hospital, University of Duisburg-Essen, Essen 45147, Germany
| | - Viktor Pfaffenrot
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University of Duisburg-Essen, Essen 45141, Germany
| | - Thomas Hulst
- Department of Neurology and Center for Translational Neuro- and Behavioral Sciences (C-TNBS), Essen University Hospital, University of Duisburg-Essen, Essen 45147, Germany; Erasmus University College, Rotterdam 3011 HP, the Netherlands
| | - Alexander Gussew
- University Clinic and Outpatient Clinic for Radiology, Department for Radiation Medicine, University Hospital Halle (Saale), Ernst-Grube-Str. 40, Halle (Saale) 06120, Germany
| | - Stefan Maderwald
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University of Duisburg-Essen, Essen 45141, Germany
| | - Sophia L Göricke
- Institute of Diagnostic and Interventional Neuroradiology, Essen University Hospital, University of Duisburg-Essen, Essen 45141, Germany
| | - Martina Minnerop
- Institute of Neuroscience and Medicine (INM-1), Research Centre Juelich, Juelich 52425, Germany; Department of Neurology, Center for Movement Disorders and Neuromodulation, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine University Düsseldorf, Düsseldorf 40225, Germany; Institute of Clinical Neuroscience and Medical Psychology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine University Düsseldorf, Düsseldorf 40225, Germany
| | - Mark E Ladd
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University of Duisburg-Essen, Essen 45141, Germany; Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg 69120, Germany; Faculty of Physics and Astronomy and Faculty of Medicine, Heidelberg University, Heidelberg 69120, Germany
| | - Jürgen R Reichenbach
- Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital, Jena 07743, Germany
| | - Dagmar Timmann
- Department of Neurology and Center for Translational Neuro- and Behavioral Sciences (C-TNBS), Essen University Hospital, University of Duisburg-Essen, Essen 45147, Germany; Erwin L. Hahn Institute for Magnetic Resonance Imaging, University of Duisburg-Essen, Essen 45141, Germany
| | - Andreas Deistung
- Department of Neurology and Center for Translational Neuro- and Behavioral Sciences (C-TNBS), Essen University Hospital, University of Duisburg-Essen, Essen 45147, Germany; University Clinic and Outpatient Clinic for Radiology, Department for Radiation Medicine, University Hospital Halle (Saale), Ernst-Grube-Str. 40, Halle (Saale) 06120, Germany; Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital, Jena 07743, Germany.
| |
Collapse
|
26
|
Ward IL, Raven EP, de la Rosa S, Jones DK, Teufel C, von dem Hagen E. White matter microstructure in face and body networks predicts facial expression and body posture perception across development. Hum Brain Mapp 2023; 44:2307-2322. [PMID: 36661194 PMCID: PMC10028674 DOI: 10.1002/hbm.26211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 12/05/2022] [Accepted: 01/07/2023] [Indexed: 01/21/2023] Open
Abstract
Facial expression and body posture recognition have protracted developmental trajectories. Interactions between face and body perception, such as the influence of body posture on facial expression perception, also change with development. While the brain regions underpinning face and body processing are well-defined, little is known about how white-matter tracts linking these regions relate to perceptual development. Here, we obtained complementary diffusion magnetic resonance imaging (MRI) measures (fractional anisotropy [FA], spherical mean Ṧμ ), and a quantitative MRI myelin-proxy measure (R1), within white-matter tracts of face- and body-selective networks in children and adolescents and related these to perceptual development. In tracts linking occipital and fusiform face areas, facial expression perception was predicted by age-related maturation, as measured by Ṧμ and R1, as well as age-independent individual differences in microstructure, captured by FA and R1. Tract microstructure measures linking posterior superior temporal sulcus body region with anterior temporal lobe (ATL) were related to the influence of body on facial expression perception, supporting ATL as a site of face and body network convergence. Overall, our results highlight age-dependent and age-independent constraints that white-matter microstructure poses on perceptual abilities during development and the importance of complementary microstructural measures in linking brain structure and behaviour.
Collapse
Affiliation(s)
- Isobel L. Ward
- Cardiff University Brain Research Imaging Centre, School of PsychologyCardiff UniversityCardiffUK
| | - Erika P. Raven
- Cardiff University Brain Research Imaging Centre, School of PsychologyCardiff UniversityCardiffUK
- Center for Biomedical Imaging, Department of RadiologyNew York University Grossman School of MedicineNew YorkNew YorkUSA
| | | | - Derek K. Jones
- Cardiff University Brain Research Imaging Centre, School of PsychologyCardiff UniversityCardiffUK
| | - Christoph Teufel
- Cardiff University Brain Research Imaging Centre, School of PsychologyCardiff UniversityCardiffUK
| | - Elisabeth von dem Hagen
- Cardiff University Brain Research Imaging Centre, School of PsychologyCardiff UniversityCardiffUK
| |
Collapse
|
27
|
van Gelderen P, Li X, de Zwart JA, Beck ES, Okar SV, Huang Y, Lai K, Sulam J, van Zijl PCM, Reich DS, Duyn JH, Liu J. Effect of motion, cortical orientation and spatial resolution on quantitative imaging of cortical R 2* and magnetic susceptibility at 0.3 mm in-plane resolution at 7 T. Neuroimage 2023; 270:119992. [PMID: 36858332 PMCID: PMC10278242 DOI: 10.1016/j.neuroimage.2023.119992] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Revised: 02/17/2023] [Accepted: 02/25/2023] [Indexed: 03/03/2023] Open
Abstract
MR images of the effective relaxation rate R2* and magnetic susceptibility χ derived from multi-echo T2*-weighted (T2*w) MRI can provide insight into iron and myelin distributions in the brain, with the potential of providing biomarkers for neurological disorders. Quantification of R2* and χ at submillimeter resolution in the cortex in vivo has been difficult because of challenges such as head motion, limited signal to noise ratio, long scan time, and motion related magnetic field fluctuations. This work aimed to improve the robustness for quantifying intracortical R2* and χ and analyze the effects from motion, spatial resolution, and cortical orientation. T2*w data was acquired with a spatial resolution of 0.3 × 0.3 × 0.4 mm3 at 7 T and downsampled to various lower resolutions. A combined correction for motion and B0 changes was deployed using volumetric navigators. Such correction improved the T2*w image quality rated by experienced image readers and test-retest reliability of R2* and χ quantification with reduced median inter-scan differences up to 10 s-1 and 5 ppb, respectively. R2* and χ near the line of Gennari, a cortical layer high in iron and myelin, were as much as 10 s-1 and 10 ppb higher than the region at adjacent cortical depth. In addition, a significant effect due to the cortical orientation relative to the static field (B0) was observed in χ with a peak-to-peak amplitude of about 17 ppb. In retrospectively downsampled data, the capability to distinguish different cortical depth regions based on R2* or χ contrast remained up to isotropic 0.5 mm resolution. This study highlights the unique characteristics of R2* and χ along the cortical depth at submillimeter resolution and the need for motion and B0 corrections for their robust quantification in vivo.
Collapse
Affiliation(s)
- Peter van Gelderen
- Advanced MRI Section, Laboratory of Functional and Molecular Imaging, NINDS, NIH, Bethesda, MD, United States of America
| | - Xu Li
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, United States of America; Department of Radiology and Radiological Sciences, Johns Hopkins University, Baltimore, MD, United States of America
| | - Jacco A de Zwart
- Advanced MRI Section, Laboratory of Functional and Molecular Imaging, NINDS, NIH, Bethesda, MD, United States of America
| | - Erin S Beck
- Translational Neurology Section, NINDS, NIH, Bethesda, MD, United States of America; Department of Neurology, Icahn School of Medicine at Mount Sinai, New York City, NY, United States of America
| | - Serhat V Okar
- Translational Neurology Section, NINDS, NIH, Bethesda, MD, United States of America
| | - Yujia Huang
- Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, United States of America
| | - KuoWei Lai
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, United States of America; Department of Electrical & Computer Engineering, Georgia Institute of Technology, Atlanta, GA, United States of America
| | - Jeremias Sulam
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, United States of America
| | - Peter C M van Zijl
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, United States of America; Department of Radiology and Radiological Sciences, Johns Hopkins University, Baltimore, MD, United States of America
| | - Daniel S Reich
- Translational Neurology Section, NINDS, NIH, Bethesda, MD, United States of America
| | - Jeff H Duyn
- Advanced MRI Section, Laboratory of Functional and Molecular Imaging, NINDS, NIH, Bethesda, MD, United States of America
| | - Jiaen Liu
- Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, United States of America.
| |
Collapse
|
28
|
Levitt J, van der Kouwe A, Jeong H, Lewis LD, Bonmassar G. The MotoNet: A 3 Tesla MRI-Conditional EEG Net with Embedded Motion Sensors. SENSORS (BASEL, SWITZERLAND) 2023; 23:3539. [PMID: 37050598 PMCID: PMC10098760 DOI: 10.3390/s23073539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 03/20/2023] [Accepted: 03/23/2023] [Indexed: 06/19/2023]
Abstract
We introduce a new electroencephalogram (EEG) net, which will allow clinicians to monitor EEG while tracking head motion. Motion during MRI limits patient scans, especially of children with epilepsy. EEG is also severely affected by motion-induced noise, predominantly ballistocardiogram (BCG) noise due to the heartbeat. METHODS The MotoNet was built using polymer thick film (PTF) EEG leads and motion sensors on opposite sides in the same flex circuit. EEG/motion measurements were made with a standard commercial EEG acquisition system in a 3 Tesla (T) MRI. A Kalman filtering-based BCG correction tool was used to clean the EEG in healthy volunteers. RESULTS MRI safety studies in 3 T confirmed the maximum heating below 1 °C. Using an MRI sequence with spatial localization gradients only, the position of the head was linearly correlated with the average motion sensor output. Kalman filtering was shown to reduce the BCG noise and recover artifact-clean EEG. CONCLUSIONS The MotoNet is an innovative EEG net design that co-locates 32 EEG electrodes with 32 motion sensors to improve both EEG and MRI signal quality. In combination with custom gradients, the position of the net can, in principle, be determined. In addition, the motion sensors can help reduce BCG noise.
Collapse
Affiliation(s)
- Joshua Levitt
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - André van der Kouwe
- Athinoula A. Martinos Center for Biomedical Engineering, Massachusetts General Hospital, Charlestown, MA 02129, USA
| | - Hongbae Jeong
- Athinoula A. Martinos Center for Biomedical Engineering, Massachusetts General Hospital, Charlestown, MA 02129, USA
| | - Laura D. Lewis
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
- Athinoula A. Martinos Center for Biomedical Engineering, Massachusetts General Hospital, Charlestown, MA 02129, USA
| | - Giorgio Bonmassar
- Athinoula A. Martinos Center for Biomedical Engineering, Massachusetts General Hospital, Charlestown, MA 02129, USA
| |
Collapse
|
29
|
Dokumacı AS, Aitken FR, Sedlacik J, Bridgen P, Tomi‐Tricot R, Mooiweer R, Vecchiato K, Wilkinson T, Casella C, Giles S, Hajnal JV, Malik SJ, O'Muircheartaigh J, Carmichael DW. Simultaneous Optimization of MP2RAGE T 1 -weighted (UNI) and FLuid And White matter Suppression (FLAWS) brain images at 7T using Extended Phase Graph (EPG) Simulations. Magn Reson Med 2023; 89:937-950. [PMID: 36352772 PMCID: PMC10100108 DOI: 10.1002/mrm.29479] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 09/16/2022] [Accepted: 09/16/2022] [Indexed: 11/11/2022]
Abstract
PURPOSE The MP2RAGE sequence is typically optimized for either T1 -weighted uniform image (UNI) or gray matter-dominant fluid and white matter suppression (FLAWS) contrast images. Here, the purpose was to optimize an MP2RAGE protocol at 7 Tesla to provide UNI and FLAWS images simultaneously in a clinically applicable acquisition time at <0.7 mm isotropic resolution. METHODS Using the extended phase graph formalism, the signal evolution of the MP2RAGE sequence was simulated incorporating T2 relaxation, diffusion, RF spoiling, and B1 + variability. Flip angles and TI were optimized at different TRs (TRMP2RAGE ) to produce an optimal contrast-to-noise ratio for UNI and FLAWS images. Simulation results were validated by comparison to MP2RAGE brain scans of 5 healthy subjects, and a final protocol at TRMP2RAGE = 4000 ms was applied in 19 subjects aged 8-62 years with and without epilepsy. RESULTS FLAWS contrast images could be obtained while maintaining >85% of the optimal UNI contrast-to-noise ratio. Using TI1 /TI2 /TRMP2RAGE of 650/2280/4000 ms, 6/8 partial Fourier in the inner phase-encoding direction, and GRAPPA factor = 4 in the other, images with 0.65 mm isotropic resolution were produced in <7.5 min. The contrast-to-noise ratio was around 20% smaller at TRMP2RAGE = 4000 ms compared to that at TRMP2RAGE = 5000 ms; however, the 20% shorter duration makes TRMP2RAGE = 4000 ms a good candidate for clinical applications example, pediatrics. CONCLUSION FLAWS and UNI images could be obtained in a single scan with 0.65 mm isotropic resolution, providing a set of high-contrast images and full brain coverage in a clinically applicable scan time. Images with excellent anatomical detail were demonstrated over a wide age range using the optimized parameter set.
Collapse
Affiliation(s)
- Ayşe Sıla Dokumacı
- Biomedical Engineering DepartmentSchool of Biomedical Engineering and Imaging Sciences, King's College London
LondonUnited Kingdom
- London Collaborative Ultra high field System (LoCUS)LondonUnited Kingdom
| | - Fraser R. Aitken
- Biomedical Engineering DepartmentSchool of Biomedical Engineering and Imaging Sciences, King's College London
LondonUnited Kingdom
- London Collaborative Ultra high field System (LoCUS)LondonUnited Kingdom
| | - Jan Sedlacik
- London Collaborative Ultra high field System (LoCUS)LondonUnited Kingdom
- Radiology DepartmentGreat Ormond Street Hospital for ChildrenLondonUnited Kingdom
| | - Pip Bridgen
- Biomedical Engineering DepartmentSchool of Biomedical Engineering and Imaging Sciences, King's College London
LondonUnited Kingdom
- London Collaborative Ultra high field System (LoCUS)LondonUnited Kingdom
| | - Raphael Tomi‐Tricot
- Biomedical Engineering DepartmentSchool of Biomedical Engineering and Imaging Sciences, King's College London
LondonUnited Kingdom
- London Collaborative Ultra high field System (LoCUS)LondonUnited Kingdom
- MR Research CollaborationsSiemens Healthcare LimitedCamberleyUnited Kingdom
| | - Ronald Mooiweer
- Biomedical Engineering DepartmentSchool of Biomedical Engineering and Imaging Sciences, King's College London
LondonUnited Kingdom
- MR Research CollaborationsSiemens Healthcare LimitedCamberleyUnited Kingdom
| | - Katy Vecchiato
- London Collaborative Ultra high field System (LoCUS)LondonUnited Kingdom
- Department of Forensic and Neurodevelopmental SciencesInstitute of Psychiatry, Psychology and Neuroscience, King's College LondonLondonUnited Kingdom
- Centre for the Developing BrainSchool of Biomedical Engineering and Imaging Sciences, King's College LondonLondonUnited Kingdom
| | - Tom Wilkinson
- Biomedical Engineering DepartmentSchool of Biomedical Engineering and Imaging Sciences, King's College London
LondonUnited Kingdom
- London Collaborative Ultra high field System (LoCUS)LondonUnited Kingdom
| | - Chiara Casella
- London Collaborative Ultra high field System (LoCUS)LondonUnited Kingdom
- Centre for the Developing BrainSchool of Biomedical Engineering and Imaging Sciences, King's College LondonLondonUnited Kingdom
| | - Sharon Giles
- Biomedical Engineering DepartmentSchool of Biomedical Engineering and Imaging Sciences, King's College London
LondonUnited Kingdom
- London Collaborative Ultra high field System (LoCUS)LondonUnited Kingdom
| | - Joseph V. Hajnal
- Biomedical Engineering DepartmentSchool of Biomedical Engineering and Imaging Sciences, King's College London
LondonUnited Kingdom
- London Collaborative Ultra high field System (LoCUS)LondonUnited Kingdom
| | - Shaihan J. Malik
- Biomedical Engineering DepartmentSchool of Biomedical Engineering and Imaging Sciences, King's College London
LondonUnited Kingdom
- London Collaborative Ultra high field System (LoCUS)LondonUnited Kingdom
| | - Jonathan O'Muircheartaigh
- London Collaborative Ultra high field System (LoCUS)LondonUnited Kingdom
- Department of Forensic and Neurodevelopmental SciencesInstitute of Psychiatry, Psychology and Neuroscience, King's College LondonLondonUnited Kingdom
- Centre for the Developing BrainSchool of Biomedical Engineering and Imaging Sciences, King's College LondonLondonUnited Kingdom
- MRC Centre for Neurodevelopmental Disorders, King's College LondonLondonUnited Kingdom
| | - David W. Carmichael
- Biomedical Engineering DepartmentSchool of Biomedical Engineering and Imaging Sciences, King's College London
LondonUnited Kingdom
- London Collaborative Ultra high field System (LoCUS)LondonUnited Kingdom
| |
Collapse
|
30
|
Woodward K, Spencer APC, Jary S, Chakkarapani E. Factors associated with MRI success in children cooled for neonatal encephalopathy and controls. Pediatr Res 2023; 93:1017-1023. [PMID: 35906304 PMCID: PMC10033414 DOI: 10.1038/s41390-022-02180-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Revised: 06/07/2022] [Accepted: 06/13/2022] [Indexed: 11/09/2022]
Abstract
OBJECTIVE To investigate if an association exists between motion artefacts on brain MRI and comprehension, co-ordination, or hyperactivity scores in children aged 6-8 years, cooled for neonatal encephalopathy (cases) and controls. METHODS Case children (n = 50) without cerebral palsy were matched with 43 controls for age, sex, and socioeconomic status. Children underwent T1-weighted (T1w), diffusion-weighted image (DWI) brain MRI and cognitive, behavioural, and motor skills assessment. Stepwise multivariable logistic regression assessed associations between unsuccessful MRI and comprehension (including Weschler Intelligence Scale for Children (WISC-IV) verbal comprehension, working memory, processing speed and full-scale IQ), co-ordination (including Movement Assessment Battery for Children (MABC-2) balance, manual dexterity, aiming and catching, and total scores) and hyperactivity (including Strengths and Difficulties Questionnaire (SDQ) hyperactivity and total difficulties scores). RESULTS Cases had lower odds of completing both T1w and DWIs (OR: 0.31, 95% CI 0.11-0.89). After adjusting for case-status and sex, lower MABC-2 balance score predicted unsuccessful T1w MRI (OR: 0.81, 95% CI 0.67-0.97, p = 0.022). Processing speed was negatively correlated with relative motion on DWI (r = -0.25, p = 0.026) and SDQ total difficulties score was lower for children with successful MRIs (p = 0.049). CONCLUSIONS Motion artefacts on brain MRI in early school-age children are related to the developmental profile. IMPACT Children who had moderate/severe neonatal encephalopathy are less likely to have successful MRI scans than matched controls. Motion artefact on MRI is associated with lower MABC-2 balance scores in both children who received therapeutic hypothermia for neonatal encephalopathy and matched controls, after controlling for case-status and sex. Exclusion of children with motion artefacts on brain MRI can introduce sampling bias, which impacts the utility of neuroimaging to understand the brain-behaviour relationship in children with functional impairments.
Collapse
Affiliation(s)
- Kathryn Woodward
- Translational Health Sciences, Bristol Medical School, University of Bristol, Bristol, UK
| | - Arthur P C Spencer
- Translational Health Sciences, Bristol Medical School, University of Bristol, Bristol, UK
- Clinical Research and Imaging Centre, University of Bristol, Bristol, UK
| | - Sally Jary
- Translational Health Sciences, Bristol Medical School, University of Bristol, Bristol, UK
| | - Ela Chakkarapani
- Translational Health Sciences, Bristol Medical School, University of Bristol, Bristol, UK.
| |
Collapse
|
31
|
Chen Z, Pawar K, Ekanayake M, Pain C, Zhong S, Egan GF. Deep Learning for Image Enhancement and Correction in Magnetic Resonance Imaging-State-of-the-Art and Challenges. J Digit Imaging 2023; 36:204-230. [PMID: 36323914 PMCID: PMC9984670 DOI: 10.1007/s10278-022-00721-9] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Revised: 09/09/2022] [Accepted: 10/17/2022] [Indexed: 11/06/2022] Open
Abstract
Magnetic resonance imaging (MRI) provides excellent soft-tissue contrast for clinical diagnoses and research which underpin many recent breakthroughs in medicine and biology. The post-processing of reconstructed MR images is often automated for incorporation into MRI scanners by the manufacturers and increasingly plays a critical role in the final image quality for clinical reporting and interpretation. For image enhancement and correction, the post-processing steps include noise reduction, image artefact correction, and image resolution improvements. With the recent success of deep learning in many research fields, there is great potential to apply deep learning for MR image enhancement, and recent publications have demonstrated promising results. Motivated by the rapidly growing literature in this area, in this review paper, we provide a comprehensive overview of deep learning-based methods for post-processing MR images to enhance image quality and correct image artefacts. We aim to provide researchers in MRI or other research fields, including computer vision and image processing, a literature survey of deep learning approaches for MR image enhancement. We discuss the current limitations of the application of artificial intelligence in MRI and highlight possible directions for future developments. In the era of deep learning, we highlight the importance of a critical appraisal of the explanatory information provided and the generalizability of deep learning algorithms in medical imaging.
Collapse
Affiliation(s)
- Zhaolin Chen
- Monash Biomedical Imaging, Monash University, Melbourne, VIC, 3168, Australia.
- Department of Data Science and AI, Monash University, Melbourne, VIC, Australia.
| | - Kamlesh Pawar
- Monash Biomedical Imaging, Monash University, Melbourne, VIC, 3168, Australia
| | - Mevan Ekanayake
- Monash Biomedical Imaging, Monash University, Melbourne, VIC, 3168, Australia
- Department of Electrical and Computer Systems Engineering, Monash University, Melbourne, VIC, Australia
| | - Cameron Pain
- Monash Biomedical Imaging, Monash University, Melbourne, VIC, 3168, Australia
- Department of Electrical and Computer Systems Engineering, Monash University, Melbourne, VIC, Australia
| | - Shenjun Zhong
- Monash Biomedical Imaging, Monash University, Melbourne, VIC, 3168, Australia
- National Imaging Facility, Brisbane, QLD, Australia
| | - Gary F Egan
- Monash Biomedical Imaging, Monash University, Melbourne, VIC, 3168, Australia
- Turner Institute for Brain and Mental Health, Monash University, Melbourne, VIC, Australia
| |
Collapse
|
32
|
Raimondo L, Priovoulos N, Passarinho C, Heij J, Knapen T, Dumoulin SO, Siero JCW, van der Zwaag W. Robust high spatio-temporal line-scanning fMRI in humans at 7T using multi-echo readouts, denoising and prospective motion correction. J Neurosci Methods 2023; 384:109746. [PMID: 36403778 DOI: 10.1016/j.jneumeth.2022.109746] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Revised: 10/12/2022] [Accepted: 11/11/2022] [Indexed: 11/18/2022]
Abstract
BACKGROUND Functional magnetic resonance imaging (fMRI), typically using blood oxygenation level-dependent (BOLD) contrast weighted imaging, allows the study of brain function with millimeter spatial resolution and temporal resolution of one to a few seconds. At a mesoscopic scale, neurons in the human brain are spatially organized in structures with dimensions of hundreds of micrometers, while they communicate at the millisecond timescale. For this reason, it is important to develop an fMRI method with simultaneous high spatial and temporal resolution. Line-scanning promises to reach this goal at the cost of volume coverage. NEW METHOD Here, we release a comprehensive update to human line-scanning fMRI. First, we investigated multi-echo line-scanning with five different protocols varying the number of echoes and readout bandwidth while keeping the TR constant. In these, we compared different echo combination approaches in terms of BOLD activation (sensitivity) and temporal signal-to-noise ratio. Second, we implemented an adaptation of NOise reduction with DIstribution Corrected principal component analysis (NORDIC) thermal noise removal for line-scanning fMRI data. Finally, we tested three image-based navigators for motion correction and investigated different ways of performing fMRI analysis on the timecourses which were influenced by the insertion of the navigators themselves. RESULTS The presented improvements are relatively straightforward to implement; multi-echo readout and NORDIC denoising together, significantly improve data quality in terms of tSNR and t-statistical values, while motion correction makes line-scanning fMRI more robust. COMPARISON WITH EXISTING METHODS Multi-echo acquisitions and denoising have previously been applied in 3D magnetic resonance imaging. Their combination and application to 1D line-scanning is novel. The current proposed method greatly outperforms the previous line-scanning acquisitions with single-echo acquisition, in terms of tSNR (4.0 for single-echo line-scanning and 36.2 for NORDIC-denoised multi-echo) and t-statistical values (3.8 for single-echo line-scanning and 25.1 for NORDIC-denoised multi-echo line-scanning). CONCLUSIONS Line-scanning fMRI was advanced compared to its previous implementation in order to improve sensitivity and reliability. The improved line-scanning acquisition could be used, in the future, for neuroscientific and clinical applications.
Collapse
Affiliation(s)
- Luisa Raimondo
- Spinoza Centre for Neuroimaging, Meibergdreef 75, 1105 BK Amsterdam, Netherlands; Computational Cognitive Neuroscience and Neuroimaging, Netherlands Institute for Neuroscience, Meibergdreef 47, 1105 BA Amsterdam, Netherlands; Experimental and Applied Psychology, VU University, De Boelelaan 1105, 1081 HV Amsterdam, Netherlands.
| | - Nikos Priovoulos
- Spinoza Centre for Neuroimaging, Meibergdreef 75, 1105 BK Amsterdam, Netherlands; Computational Cognitive Neuroscience and Neuroimaging, Netherlands Institute for Neuroscience, Meibergdreef 47, 1105 BA Amsterdam, Netherlands.
| | - Catarina Passarinho
- Spinoza Centre for Neuroimaging, Meibergdreef 75, 1105 BK Amsterdam, Netherlands; Institute for Systems and Robotics, Instituto Superior Técnico, University of Lisbon, Av. Rovisco Pais 1, 1049-001 Lisbon, Portugal.
| | - Jurjen Heij
- Spinoza Centre for Neuroimaging, Meibergdreef 75, 1105 BK Amsterdam, Netherlands; Computational Cognitive Neuroscience and Neuroimaging, Netherlands Institute for Neuroscience, Meibergdreef 47, 1105 BA Amsterdam, Netherlands; Experimental and Applied Psychology, VU University, De Boelelaan 1105, 1081 HV Amsterdam, Netherlands.
| | - Tomas Knapen
- Spinoza Centre for Neuroimaging, Meibergdreef 75, 1105 BK Amsterdam, Netherlands; Computational Cognitive Neuroscience and Neuroimaging, Netherlands Institute for Neuroscience, Meibergdreef 47, 1105 BA Amsterdam, Netherlands; Experimental and Applied Psychology, VU University, De Boelelaan 1105, 1081 HV Amsterdam, Netherlands.
| | - Serge O Dumoulin
- Spinoza Centre for Neuroimaging, Meibergdreef 75, 1105 BK Amsterdam, Netherlands; Computational Cognitive Neuroscience and Neuroimaging, Netherlands Institute for Neuroscience, Meibergdreef 47, 1105 BA Amsterdam, Netherlands; Experimental Psychology, Utrecht University, PO Box 80125, 3508 TC Utrecht, Netherlands.
| | - Jeroen C W Siero
- Spinoza Centre for Neuroimaging, Meibergdreef 75, 1105 BK Amsterdam, Netherlands; Radiology, University Medical Centre Utrecht, Heidelberglaan 100, 3584 CX Utrecht, Netherlands.
| | - Wietske van der Zwaag
- Spinoza Centre for Neuroimaging, Meibergdreef 75, 1105 BK Amsterdam, Netherlands; Computational Cognitive Neuroscience and Neuroimaging, Netherlands Institute for Neuroscience, Meibergdreef 47, 1105 BA Amsterdam, Netherlands.
| |
Collapse
|
33
|
Pfaffenrot V, Koopmans PJ. Magnetization transfer weighted laminar fMRI with multi-echo FLASH. Neuroimage 2022; 264:119725. [PMID: 36328273 DOI: 10.1016/j.neuroimage.2022.119725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Revised: 10/13/2022] [Accepted: 10/30/2022] [Indexed: 11/06/2022] Open
Abstract
Laminar functional magnetic resonance imaging (fMRI) using the gradient echo (GRE) blood oxygenation level dependent (BOLD) contrast is prone to signal changes arising from large unspecific venous vessels. Alternatives based on changes of cerebral blood volume (CBV) become more popular since it is expected that this hemodynamic response is dominant in microvasculature. One approach to sensitize the signal toward changes in CBV, and to simultaneously reduce unwanted extravascular (EV) BOLD blurring, is to selectively reduce gray matter (GM) signal via magnetization transfer (MT). In this work, we use off-resonant MT-pulses with a 3D FLASH readout to perform MT-prepared (MT-prep) laminar fMRI of the primary visual cortex (V1) at multiple echo times at 7 T. With a GRE-BOLD contrast without additional MT-weighting as reference, we investigated the influence of the MT-preparation on the shape and the echo time dependency of laminar profiles. Through numerical simulations, we optimized the sequence parameters to increase the sensitivity toward signal changes induced by changes in arterial CBV and to delineate the contributions of different compartments to the signal. We show that at 7 T, GM signals can be reduced by 30 %. Our laminar fMRI responses exhibit an increased signal change in the parenchyma at very short TE compared to a BOLD-only reference as a result of reduced EV signal intensity. By varying echo times, we could show that MT-prep results in less sensitivity toward unwanted signal changes based on changes in T2*. We conclude that when accounting for nuclear overhauser enhancement effects in blood, off-resonant MT-prep combined with efficient short TE readouts can become a promising method to reduce unwanted EV venous contributions in GRE-BOLD and/or to allow scanning at much shorter echo times without incurring a sensitivity penalty in laminar fMRI.
Collapse
Affiliation(s)
- Viktor Pfaffenrot
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University of Duisburg-Essen, 45141 Essen, Germany; High Field and Hybrid MR Imaging, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany.
| | - Peter J Koopmans
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University of Duisburg-Essen, 45141 Essen, Germany; High Field and Hybrid MR Imaging, University Hospital Essen, University of Duisburg-Essen, 45147 Essen, Germany; Department of Radiation Oncology, Radboud University Medical Center, Nijmegen, the Netherlands
| |
Collapse
|
34
|
Mesoscopic in vivo human T 2* dataset acquired using quantitative MRI at 7 Tesla. Neuroimage 2022; 264:119733. [PMID: 36375782 DOI: 10.1016/j.neuroimage.2022.119733] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 10/15/2022] [Accepted: 11/03/2022] [Indexed: 11/13/2022] Open
Abstract
Mesoscopic (0.1-0.5 mm) interrogation of the living human brain is critical for advancing neuroscience and bridging the resolution gap with animal models. Despite the variety of MRI contrasts measured in recent years at the mesoscopic scale, in vivo quantitative imaging of T2* has not been performed. Here we provide a dataset containing empirical T2* measurements acquired at 0.35 × 0.35 × 0.35 mm3 voxel resolution using 7 Tesla MRI. To demonstrate unique features and high quality of this dataset, we generate flat map visualizations that reveal fine-scale cortical substructures such as layers and vessels, and we report quantitative depth-dependent T2* (as well as R2*) values in primary visual cortex and auditory cortex that are highly consistent across subjects. This dataset is freely available at https://doi.org/10.17605/OSF.IO/N5BJ7, and may prove useful for anatomical investigations of the human brain, as well as for improving our understanding of the basis of the T2*-weighted (f)MRI signal.
Collapse
|
35
|
Moore J, Jimenez J, Lin W, Powers W, Zong X. Prospective motion correction and automatic segmentation of penetrating arteries in phase contrast MRI at 7 T. Magn Reson Med 2022; 88:2088-2100. [PMID: 35713374 DOI: 10.1002/mrm.29364] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 05/21/2022] [Accepted: 05/27/2022] [Indexed: 11/09/2022]
Abstract
PURPOSE To develop a prospective motion correction (MC) method for phase contrast (PC) MRI of penetrating arteries (PAs) in centrum semiovale at 7 T and to evaluate its performance using automatic PA segmentation. METHODS Head motion was monitored and corrected during the scan based on fat navigator images. Two convolutional neural networks (CNN) were developed to automatically segment PAs and exclude surface vessels. Real-life scans with MC and without MC (NoMC) were performed to evaluate the MC performance. Motion score was calculated from the ranges of translational and rotational motion parameters. MC versus NoMC pairs with similar motion scores during MC and NoMC scans were compared. Data corrupted by motion were reacquired to further improve PA visualization. RESULTS PA counts (NPA ) and PC and magnitude contrasts (MgC) relative to neighboring tissue were significantly correlated with motion score and were higher in MC than NoMC images at motion scores above 0.5-0.8 mm. Data reacquisition further increased PC but had no significant effect on NPA and MgC. CNNs had higher sensitivity and Dice similarity coefficient for detecting PAs than a threshold-based method. CONCLUSIONS Prospective MC can improve the count and contrast of segmented PAs in the presence of severe motion. CNN-based PA segmentation has improved performance in delineating PAs than the threshold-based method.
Collapse
Affiliation(s)
- Julia Moore
- Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - Jordan Jimenez
- Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - Weili Lin
- Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
- Department of Radiology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - William Powers
- Department of Neurology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - Xiaopeng Zong
- Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
- Department of Radiology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| |
Collapse
|
36
|
Wang Y, Zhan M, Roebroeck A, De Weerd P, Kashyap S, Roberts MJ. Inconsistencies in atlas-based volumetric measures of the human nucleus basalis of Meynert: A need for high-resolution alternatives. Neuroimage 2022; 259:119421. [PMID: 35779763 DOI: 10.1016/j.neuroimage.2022.119421] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 06/10/2022] [Accepted: 06/28/2022] [Indexed: 10/17/2022] Open
Abstract
The nucleus basalis of Meynert (nbM) is the major source of cortical acetylcholine (ACh) and has been related to cognitive processes and to neurological disorders. However, spatially delineating the human nbM in MRI studies remains challenging. Due to the absence of a functional localiser for the human nbM, studies to date have localised it using nearby neuroanatomical landmarks or using probabilistic atlases. To understand the feasibility of MRI of the nbM we set our four goals; our first goal was to review current human nbM region-of-interest (ROI) selection protocols used in MRI studies, which we found have reported highly variable nbM volume estimates. Our next goal was to quantify and discuss the limitations of existing atlas-based volumetry of nbM. We found that the identified ROI volume depends heavily on the atlas used and on the probabilistic threshold set. In addition, we found large disparities even for data/studies using the same atlas and threshold. To test whether spatial resolution contributes to volume variability, as our third goal, we developed a novel nbM mask based on the normalized BigBrain dataset. We found that as long as the spatial resolution of the target data was 1.3 mm isotropic or above, our novel nbM mask offered realistic and stable volume estimates. Finally, as our last goal we tried to discern nbM using publicly available and novel high resolution structural MRI ex vivo MRI datasets. We find that, using an optimised 9.4T quantitative T2⁎ ex vivo dataset, the nbM can be visualised using MRI. We conclude caution is needed when applying the current methods of mapping nbM, especially for high resolution MRI data. Direct imaging of the nbM appears feasible and would eliminate the problems we identify, although further development is required to allow such imaging using standard (f)MRI scanning.
Collapse
Affiliation(s)
- Yawen Wang
- Department of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, Netherlands.
| | - Minye Zhan
- Department of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, Netherlands; U992 (Cognitive neuroimaging unit), NeuroSpin, INSERM-CEA, Gif sur Yvette, France
| | - Alard Roebroeck
- Department of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, Netherlands
| | - Peter De Weerd
- Department of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, Netherlands
| | - Sriranga Kashyap
- Department of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, Netherlands; Techna Institute, University Health Network, Toronto, ON, Canada
| | - Mark J Roberts
- Department of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, Netherlands.
| |
Collapse
|
37
|
Andersen M, Laustsen M, Boer V. Accuracy investigations for volumetric head-motion navigators with and without EPI at 7 T. Magn Reson Med 2022; 88:1198-1211. [PMID: 35576128 PMCID: PMC9325528 DOI: 10.1002/mrm.29296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 03/31/2022] [Accepted: 04/19/2022] [Indexed: 11/18/2022]
Abstract
PURPOSE Accuracy investigation of volumetric navigators for motion correction, with emphasis on geometric EPI distortions at ultrahigh field. METHODS High-resolution Dixon images were collected in different head positions and reconstructed to water, fat, T2 *, and B0 maps. Resolution reduction was performed, and the T2 * and B0 maps were used to apply effects of TE and EPI distortions to simulate various volumetric water and fat navigators. Registrations of the simulated navigators were compared with registrations of the original high-resolution images. RESULTS Increased accuracy was observed with increased spatial resolution for non-EPI navigators. When using EPI, the distortions had a negative effect on registration accuracy, which was most noticeable for high-resolution navigators. Parallel imaging helped to alleviate those caveats to a certain extent, and 5-fold acceleration gave close to similar accuracy to non-EPI in most cases. Shortening the TE by partial Fourier sampling was shown to be mostly beneficial, except for water navigators with long readout durations. The EPI blip direction had an influence on navigator accuracy, and positive blip gradient polarities (yielding mostly image stretching frontally) typically gave the best accuracy for water navigators, whereas no clear recommendation could be made for fat navigators. Generally, fat EPI navigators had lower accuracy than water EPI navigators with otherwise similar parameters. CONCLUSIONS Echo planar imaging has been widely used for MRI navigators, but the induced distortions reduce navigator accuracy at ultrahigh field. This study can help protocol optimization and guide the complex tradeoff between resolution and EPI acceleration in navigator parameter setup.
Collapse
Affiliation(s)
- Mads Andersen
- Philips HealthcareCopenhagenDenmark
- Lund University Bioimaging Center, Lund UniversityLundSweden
| | - Malte Laustsen
- Center for Magnetic Resonance, Department of Health TechnologyTechnical University of DenmarkLyngbyDenmark
- Danish Research Center for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and ResearchCopenhagen University Hospital – Amager and HvidovreCopenhagenDenmark
| | - Vincent Boer
- Danish Research Center for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and ResearchCopenhagen University Hospital – Amager and HvidovreCopenhagenDenmark
| |
Collapse
|
38
|
Plumley A, Watkins L, Treder M, Liebig P, Murphy K, Kopanoglu E. Rigid motion-resolved B1+ prediction using deep learning for real-time parallel-transmission pulse design. Magn Reson Med 2022; 87:2254-2270. [PMID: 34958134 PMCID: PMC7613077 DOI: 10.1002/mrm.29132] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 11/30/2021] [Accepted: 12/03/2021] [Indexed: 11/19/2022]
Abstract
PURPOSE Tailored parallel-transmit (pTx) pulses produce uniform excitation profiles at 7 T, but are sensitive to head motion. A potential solution is real-time pulse redesign. A deep learning framework is proposed to estimate pTx B 1 + distributions following within-slice motion, which can then be used for tailored pTx pulse redesign. METHODS Using simulated data, conditional generative adversarial networks were trained to predict B 1 + distributions in the head following a displacement. Predictions were made for two virtual body models that were not included in training. Predicted maps were compared with ground-truth (simulated, following motion) B1 maps. Tailored pTx pulses were designed using B1 maps at the original position (simulated, no motion) and evaluated using simulated B1 maps at displaced position (ground-truth maps) to quantify motion-related excitation error. A second pulse was designed using predicted maps (also evaluated on ground-truth maps) to investigate improvement offered by the proposed method. RESULTS Predicted B 1 + maps corresponded well with ground-truth maps. Error in predicted maps was lower than motion-related error in 99% and 67% of magnitude and phase evaluations, respectively. Worst-case flip-angle normalized RMS error due to motion (76% of target flip angle) was reduced by 59% when pulses were redesigned using predicted maps. CONCLUSION We propose a framework for predicting B 1 + maps online with deep neural networks. Predicted maps can then be used for real-time tailored pulse redesign, helping to overcome head motion-related error in pTx.
Collapse
Affiliation(s)
- Alix Plumley
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, United Kingdom
| | - Luke Watkins
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, United Kingdom
- School of Physics & Astronomy, Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff, United Kingdom
| | - Matthias Treder
- School of Computer Science and Informatics, Cardiff University, Cardiff, United Kingdom
| | | | - Kevin Murphy
- School of Physics & Astronomy, Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff, United Kingdom
| | - Emre Kopanoglu
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, United Kingdom
| |
Collapse
|
39
|
Laustsen M, Andersen M, Xue R, Madsen KH, Hanson LG. Tracking of rigid head motion during MRI using an EEG system. Magn Reson Med 2022; 88:986-1001. [PMID: 35468237 PMCID: PMC9325421 DOI: 10.1002/mrm.29251] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Revised: 02/26/2022] [Accepted: 03/08/2022] [Indexed: 11/21/2022]
Abstract
Purpose To demonstrate a novel method for tracking of head movements during MRI using electroencephalography (EEG) hardware for recording signals induced by native imaging gradients. Theory and Methods Gradient switching during simultaneous EEG–fMRI induces distortions in EEG signals, which depend on subject head position and orientation. When EEG electrodes are interconnected with high‐impedance carbon wire loops, the induced voltages are linear combinations of the temporal gradient waveform derivatives. We introduce head tracking based on these signals (CapTrack) involving 3 steps: (1) phantom scanning is used to characterize the target sequence and a fast calibration sequence; (2) a linear relation between changes of induced signals and head pose is established using the calibration sequence; and (3) induced signals recorded during target sequence scanning are used for tracking and retrospective correction of head movement without prolonging the scan time of the target sequence. Performance of CapTrack is compared directly to interleaved navigators. Results Head‐pose tracking at 27.5 Hz during echo planar imaging (EPI) was demonstrated with close resemblance to rigid body alignment (mean absolute difference: [0.14 0.38 0.15]‐mm translation, [0.30 0.27 0.22]‐degree rotation). Retrospective correction of 3D gradient‐echo imaging shows an increase of average edge strength of 12%/−0.39% for instructed/uninstructed motion with CapTrack pose estimates, with a tracking interval of 1561 ms and high similarity to interleaved navigator estimates (mean absolute difference: [0.13 0.33 0.12] mm, [0.28 0.15 0.22] degrees). Conclusion Motion can be estimated from recordings of gradient switching with little or no sequence modification, optionally in real time at low computational burden and synchronized to image acquisition, using EEG equipment already found at many research institutions.
Collapse
Affiliation(s)
- Malte Laustsen
- Section for Magnetic Resonance, DTU Health Tech, Technical University of Denmark, Kgs. Lyngby, Denmark.,Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Copenhagen, Denmark.,Sino-Danish Centre for Education and Research, Aarhus, Denmark.,University of Chinese Academic of Sciences, Beijing, China
| | - Mads Andersen
- Philips Healthcare, Copenhagen, Denmark.,Lund University Bioimaging Center, Lund University, Lund, Sweden
| | - Rong Xue
- University of Chinese Academic of Sciences, Beijing, China.,State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China.,Beijing Institute for Brain Disorders, Beijing, China
| | - Kristoffer H Madsen
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Copenhagen, Denmark.,DTU Compute, Technical University of Denmark, Kgs. Lyngby, Denmark
| | - Lars G Hanson
- Section for Magnetic Resonance, DTU Health Tech, Technical University of Denmark, Kgs. Lyngby, Denmark.,Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Copenhagen, Denmark
| |
Collapse
|
40
|
Vaculčiaková L, Podranski K, Edwards LJ, Ocal D, Veale T, Fox NC, Haak R, Ehses P, Callaghan MF, Pine KJ, Weiskopf N. Combining navigator and optical prospective motion correction for high-quality 500 μm resolution quantitative multi-parameter mapping at 7T. Magn Reson Med 2022; 88:787-801. [PMID: 35405027 DOI: 10.1002/mrm.29253] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2021] [Revised: 03/10/2022] [Accepted: 03/10/2022] [Indexed: 12/15/2022]
Abstract
PURPOSE High-resolution quantitative multi-parameter mapping shows promise for non-invasively characterizing human brain microstructure but is limited by physiological artifacts. We implemented corrections for rigid head movement and respiration-related B0-fluctuations and evaluated them in healthy volunteers and dementia patients. METHODS Camera-based optical prospective motion correction (PMC) and FID navigator correction were implemented in a gradient and RF-spoiled multi-echo 3D gradient echo sequence for mapping proton density (PD), longitudinal relaxation rate (R1) and effective transverse relaxation rate (R2*). We studied their effectiveness separately and in concert in young volunteers and then evaluated the navigator correction (NAVcor) with PMC in a group of elderly volunteers and dementia patients. We used spatial homogeneity within white matter (WM) and gray matter (GM) and scan-rescan measures as quality metrics. RESULTS NAVcor and PMC reduced artifacts and improved the homogeneity and reproducibility of parameter maps. In elderly participants, NAVcor improved scan-rescan reproducibility of parameter maps (coefficient of variation decreased by 14.7% and 11.9% within WM and GM respectively). Spurious inhomogeneities within WM were reduced more in the elderly than in the young cohort (by 9% vs. 2%). PMC increased regional GM/WM contrast and was especially important in the elderly cohort, which moved twice as much as the young cohort. We did not find a significant interaction between the two corrections. CONCLUSION Navigator correction and PMC significantly improved the quality of PD, R1, and R2* maps, particularly in less compliant elderly volunteers and dementia patients.
Collapse
Affiliation(s)
- Lenka Vaculčiaková
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Kornelius Podranski
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Luke J Edwards
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Dilek Ocal
- The Dementia Research Centre, Department of Neurodegenerative Disease, UCL Queen Square Institute of Neurology, London, UK
| | - Thomas Veale
- The Dementia Research Centre, Department of Neurodegenerative Disease, UCL Queen Square Institute of Neurology, London, UK.,UK Dementia Research Institute at UCL, UCL, London, UK
| | - Nick C Fox
- The Dementia Research Centre, Department of Neurodegenerative Disease, UCL Queen Square Institute of Neurology, London, UK.,UK Dementia Research Institute at UCL, UCL, London, UK
| | - Rainer Haak
- Department of Cariology, Endodontology and Periodontology, University of Leipzig, Leipzig, Germany
| | - Philipp Ehses
- Department of MR Physics, German Center for Neurodegenerative Diseases, Bonn, Germany
| | - Martina F Callaghan
- The Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, University College London, London, UK
| | - Kerrin J Pine
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Nikolaus Weiskopf
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany.,The Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, University College London, London, UK.,Felix Bloch Institute for Solid State Physics, Faculty of Physics and Earth Sciences, Leipzig University, Leipzig, Germany
| |
Collapse
|
41
|
Wilferth T, Müller M, Gast LV, Ruck L, Meyerspeer M, Lopez Kolkovsky AL, Uder M, Dörfler A, Nagel AM. Motion‐corrected
23
Na MRI
of the human brain using interleaved
1
H 3D
navigator images. Magn Reson Med 2022; 88:309-321. [DOI: 10.1002/mrm.29221] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 02/15/2022] [Accepted: 02/16/2022] [Indexed: 12/23/2022]
Affiliation(s)
- Tobias Wilferth
- Institute of Radiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
| | - Max Müller
- Institute of Radiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
| | - Lena V. Gast
- Institute of Radiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
| | - Laurent Ruck
- Institute of Radiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
| | - Martin Meyerspeer
- High‐Field MR Center, Center for Medical Physics and Biomedical Engineering Medical University of Vienna Vienna Austria
| | - Alfredo L. Lopez Kolkovsky
- NMR Laboratory, Neuromuscular Investigation Center Institute of Myology Paris France
- NMR Laboratory CEA/DRF/IBFJ/Molecular Imaging Research Center Paris France
| | - Michael Uder
- Institute of Radiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
| | - Arnd Dörfler
- Department of Neuroradiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
| | - Armin M. Nagel
- Institute of Radiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
- Division of Medical Physics in Radiology German Cancer Research Center (DKFZ) Heidelberg Germany
| |
Collapse
|
42
|
Pawar K, Chen Z, Shah NJ, Egan GF. Suppressing motion artefacts in MRI using an Inception-ResNet network with motion simulation augmentation. NMR IN BIOMEDICINE 2022; 35:e4225. [PMID: 31865624 DOI: 10.1002/nbm.4225] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Revised: 10/24/2019] [Accepted: 10/24/2019] [Indexed: 06/10/2023]
Abstract
The suppression of motion artefacts from MR images is a challenging task. The purpose of this paper was to develop a standalone novel technique to suppress motion artefacts in MR images using a data-driven deep learning approach. A simulation framework was developed to generate motion-corrupted images from motion-free images using randomly generated motion profiles. An Inception-ResNet deep learning network architecture was used as the encoder and was augmented with a stack of convolution and upsampling layers to form an encoder-decoder network. The network was trained on simulated motion-corrupted images to identify and suppress those artefacts attributable to motion. The network was validated on unseen simulated datasets and real-world experimental motion-corrupted in vivo brain datasets. The trained network was able to suppress the motion artefacts in the reconstructed images, and the mean structural similarity (SSIM) increased from 0.9058 to 0.9338. The network was also able to suppress the motion artefacts from the real-world experimental dataset, and the mean SSIM increased from 0.8671 to 0.9145. The motion correction of the experimental datasets demonstrated the effectiveness of the motion simulation generation process. The proposed method successfully removed motion artefacts and outperformed an iterative entropy minimization method in terms of the SSIM index and normalized root mean squared error, which were 5-10% better for the proposed method. In conclusion, a novel, data-driven motion correction technique has been developed that can suppress motion artefacts from motion-corrupted MR images. The proposed technique is a standalone, post-processing method that does not interfere with data acquisition or reconstruction parameters, thus making it suitable for routine clinical practice.
Collapse
Affiliation(s)
- Kamlesh Pawar
- Monash Biomedical Imaging, Monash University, Melbourne, Australia
- School of Psychological Sciences, Monash University, Melbourne, Australia
| | - Zhaolin Chen
- Monash Biomedical Imaging, Monash University, Melbourne, Australia
| | - N Jon Shah
- Monash Biomedical Imaging, Monash University, Melbourne, Australia
- Research Centre Jülich, Institute of Medicine, Jülich, Germany
| | - Gary F Egan
- Monash Biomedical Imaging, Monash University, Melbourne, Australia
- School of Psychological Sciences, Monash University, Melbourne, Australia
| |
Collapse
|
43
|
Xu X, Kothapalli SVVN, Liu J, Kahali S, Gan W, Yablonskiy DA, Kamilov US. Learning-based motion artifact removal networks for quantitative R 2 ∗ mapping. Magn Reson Med 2022; 88:106-119. [PMID: 35257400 DOI: 10.1002/mrm.29188] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 01/11/2022] [Accepted: 01/18/2022] [Indexed: 11/12/2022]
Abstract
PURPOSE To introduce two novel learning-based motion artifact removal networks (LEARN) for the estimation of quantitative motion- and B 0 -inhomogeneity-corrected R 2 ∗ maps from motion-corrupted multi-Gradient-Recalled Echo (mGRE) MRI data. METHODS We train two convolutional neural networks (CNNs) to correct motion artifacts for high-quality estimation of quantitative B 0 -inhomogeneity-corrected R 2 ∗ maps from mGRE sequences. The first CNN, LEARN-IMG, performs motion correction on complex mGRE images, to enable the subsequent computation of high-quality motion-free quantitative R 2 ∗ (and any other mGRE-enabled) maps using the standard voxel-wise analysis or machine learning-based analysis. The second CNN, LEARN-BIO, is trained to directly generate motion- and B 0 -inhomogeneity-corrected quantitative R 2 ∗ maps from motion-corrupted magnitude-only mGRE images by taking advantage of the biophysical model describing the mGRE signal decay. RESULTS We show that both CNNs trained on synthetic MR images are capable of suppressing motion artifacts while preserving details in the predicted quantitative R 2 ∗ maps. Significant reduction of motion artifacts on experimental in vivo motion-corrupted data has also been achieved by using our trained models. CONCLUSION Both LEARN-IMG and LEARN-BIO can enable the computation of high-quality motion- and B 0 -inhomogeneity-corrected R 2 ∗ maps. LEARN-IMG performs motion correction on mGRE images and relies on the subsequent analysis for the estimation of R 2 ∗ maps, while LEARN-BIO directly performs motion- and B 0 -inhomogeneity-corrected R 2 ∗ estimation. Both LEARN-IMG and LEARN-BIO jointly process all the available gradient echoes, which enables them to exploit spatial patterns available in the data. The high computational speed of LEARN-BIO is an advantage that can lead to a broader clinical application.
Collapse
Affiliation(s)
- Xiaojian Xu
- Department of Computer Science and Engineering, Washington University in St. Louis, St. Louis, Missouri, USA
| | | | - Jiaming Liu
- Department of Electrical and Systems Engineering, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Sayan Kahali
- Department of Radiology, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Weijie Gan
- Department of Computer Science and Engineering, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Dmitriy A Yablonskiy
- Department of Radiology, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Ulugbek S Kamilov
- Department of Computer Science and Engineering, Washington University in St. Louis, St. Louis, Missouri, USA.,Department of Electrical and Systems Engineering, Washington University in St. Louis, St. Louis, Missouri, USA
| |
Collapse
|
44
|
Slipsager JM, Glimberg SL, Højgaard L, Paulsen RR, Wighton P, Tisdall MD, Jaimes C, Gagoski BA, Grant PE, van der Kouwe A, Olesen OV, Frost R. Comparison of prospective and retrospective motion correction in 3D-encoded neuroanatomical MRI. Magn Reson Med 2022; 87:629-645. [PMID: 34490929 PMCID: PMC8635810 DOI: 10.1002/mrm.28991] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 07/17/2021] [Accepted: 08/10/2021] [Indexed: 02/03/2023]
Abstract
PURPOSE To compare prospective motion correction (PMC) and retrospective motion correction (RMC) in Cartesian 3D-encoded MPRAGE scans and to investigate the effects of correction frequency and parallel imaging on the performance of RMC. METHODS Head motion was estimated using a markerless tracking system and sent to a modified MPRAGE sequence, which can continuously update the imaging FOV to perform PMC. The prospective correction was applied either before each echo train (before-ET) or at every sixth readout within the ET (within-ET). RMC was applied during image reconstruction by adjusting k-space trajectories according to the measured motion. The motion correction frequency was retrospectively increased with RMC or decreased with reverse RMC. Phantom and in vivo experiments were used to compare PMC and RMC, as well as to compare within-ET and before-ET correction frequency during continuous motion. The correction quality was quantitatively evaluated using the structural similarity index measure with a reference image without motion correction and without intentional motion. RESULTS PMC resulted in superior image quality compared to RMC both visually and quantitatively. Increasing the correction frequency from before-ET to within-ET reduced the motion artifacts in RMC. A hybrid PMC and RMC correction, that is, retrospectively increasing the correction frequency of before-ET PMC to within-ET, also reduced motion artifacts. Inferior performance of RMC compared to PMC was shown with GRAPPA calibration data without intentional motion and without any GRAPPA acceleration. CONCLUSION Reductions in local Nyquist violations with PMC resulted in superior image quality compared to RMC. Increasing the motion correction frequency to within-ET reduced the motion artifacts in both RMC and PMC.
Collapse
Affiliation(s)
- Jakob M. Slipsager
- DTU Compute, Technical University of Denmark, Denmark
- Dept. of Clinical Physiology, Nuclear Medicine & PET, Rigshospitalet, University of Copenhagen, Denmark
- TracInnovations, Ballerup, Denmark
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts
| | | | - Liselotte Højgaard
- Dept. of Clinical Physiology, Nuclear Medicine & PET, Rigshospitalet, University of Copenhagen, Denmark
| | | | - Paul Wighton
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts
| | - M. Dylan Tisdall
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Camilo Jaimes
- Boston Children’s Hospital, Boston, Massachusetts
- Dept. of Radiology, Harvard Medical School, Boston, Massachusetts
| | - Borjan A. Gagoski
- Dept. of Radiology, Harvard Medical School, Boston, Massachusetts
- Fetal-Neonatal Neuroimaging & Developmental Science Center, Boston Children’s Hospital, Boston, Massachusetts
| | - P. Ellen Grant
- Dept. of Radiology, Harvard Medical School, Boston, Massachusetts
- Fetal-Neonatal Neuroimaging & Developmental Science Center, Boston Children’s Hospital, Boston, Massachusetts
| | - André van der Kouwe
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts
- Dept. of Radiology, Harvard Medical School, Boston, Massachusetts
| | - Oline V. Olesen
- DTU Compute, Technical University of Denmark, Denmark
- Dept. of Clinical Physiology, Nuclear Medicine & PET, Rigshospitalet, University of Copenhagen, Denmark
- TracInnovations, Ballerup, Denmark
| | - Robert Frost
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts
- Dept. of Radiology, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
45
|
Polak D, Splitthoff DN, Clifford B, Lo WC, Huang SY, Conklin J, Wald LL, Setsompop K, Cauley S. Scout accelerated motion estimation and reduction (SAMER). Magn Reson Med 2022; 87:163-178. [PMID: 34390505 PMCID: PMC8616778 DOI: 10.1002/mrm.28971] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Revised: 06/29/2021] [Accepted: 07/26/2021] [Indexed: 01/03/2023]
Abstract
PURPOSE To demonstrate a navigator/tracking-free retrospective motion estimation technique that facilitates clinically acceptable reconstruction time. METHODS Scout accelerated motion estimation and reduction (SAMER) uses a single 3-5 s, low-resolution scout scan and a novel sequence reordering to independently determine motion states by minimizing the data-consistency error in a SENSE plus motion forward model. This eliminates time-consuming alternating optimization as no updates to the imaging volume are required during the motion estimation. The SAMER approach was assessed quantitatively through extensive simulation and was evaluated in vivo across multiple motion scenarios and clinical imaging contrasts. Finally, SAMER was synergistically combined with advanced encoding (Wave-CAIPI) to facilitate rapid motion-free imaging. RESULTS The highly accelerated scout provided sufficient information to achieve accurate motion trajectory estimation (accuracy ~0.2 mm or degrees). The novel sequence reordering improved the stability of the motion parameter estimation and image reconstruction while preserving the clinical imaging contrast. Clinically acceptable computation times for the motion estimation (~4 s/shot) are demonstrated through a fully separable (non-alternating) motion search across the shots. Substantial artifact reduction was demonstrated in vivo as well as corresponding improvement in the quantitative error metric. Finally, the extension of SAMER to Wave-encoding enabled rapid high-quality imaging at up to R = 9-fold acceleration. CONCLUSION SAMER significantly improved the computational scalability for retrospective motion estimation and correction.
Collapse
Affiliation(s)
- Daniel Polak
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.,Siemens Healthcare GmbH, Erlangen, Germany
| | | | | | | | - Susie Y. Huang
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.,Harvard Medical School, Boston, Massachusetts, USA.,Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - John Conklin
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.,Harvard Medical School, Boston, Massachusetts, USA
| | - Lawrence L. Wald
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.,Harvard Medical School, Boston, Massachusetts, USA.,Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Kawin Setsompop
- Department of Radiology, Stanford School of Medicine, Stanford, California, USA
| | - Stephen Cauley
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.,Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
46
|
Clifford B, Conklin J, Huang SY, Feiweier T, Hosseini Z, Goncalves Filho ALM, Tabari A, Demir S, Lo WC, Longo MGF, Lev M, Schaefer P, Rapalino O, Setsompop K, Bilgic B, Cauley S. An artificial intelligence-accelerated 2-minute multi-shot echo planar imaging protocol for comprehensive high-quality clinical brain imaging. Magn Reson Med 2021; 87:2453-2463. [PMID: 34971463 DOI: 10.1002/mrm.29117] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 10/29/2021] [Accepted: 11/22/2021] [Indexed: 02/06/2023]
Abstract
PURPOSE We introduce and validate an artificial intelligence (AI)-accelerated multi-shot echo-planar imaging (msEPI)-based method that provides T1w, T2w, T 2 ∗ , T2-FLAIR, and DWI images with high SNR, high tissue contrast, low specific absorption rates (SAR), and minimal distortion in 2 minutes. METHODS The rapid imaging technique combines a novel machine learning (ML) scheme to limit g-factor noise amplification and improve SNR, a magnetization transfer preparation module to provide clinically desirable contrast, and high per-shot EPI undersampling factors to reduce distortion. The ML training and image reconstruction incorporates a tunable parameter for controlling the level of denoising/smoothness. The performance of the reconstruction method is evaluated across various acceleration factors, contrasts, and SNR conditions. The 2-minute protocol is directly compared to a 10-minute clinical reference protocol through deployment in a clinical setting, where five representative cases with pathology are examined. RESULTS Optimization of custom msEPI sequences and protocols was performed to balance acquisition efficiency and image quality compared to the five-fold longer clinical reference. Training data from 16 healthy subjects across multiple contrasts and orientations were used to produce ML networks at various acceleration levels. The flexibility of the ML reconstruction was demonstrated across SNR levels, and an optimized regularization was determined through radiological review. Network generalization toward novel pathology, unobserved during training, was illustrated in five clinical case studies with clinical reference images provided for comparison. CONCLUSION The rapid 2-minute msEPI-based protocol with tunable ML reconstruction allows for advantageous trade-offs between acquisition speed, SNR, and tissue contrast when compared to the five-fold slower standard clinical reference exam.
Collapse
Affiliation(s)
- Bryan Clifford
- Siemens Medical Solutions USA, Boston, Massachusetts, USA
| | - John Conklin
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Susie Y Huang
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | | | | | | | - Azadeh Tabari
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Serdest Demir
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Wei-Ching Lo
- Siemens Medical Solutions USA, Boston, Massachusetts, USA
| | | | - Michael Lev
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Pam Schaefer
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Otto Rapalino
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Kawin Setsompop
- Department of Radiology and Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Berkin Bilgic
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Stephen Cauley
- Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
47
|
Unger DM, Wiest R, Kiefer C, Raillard M, Dutil GF, Stein VM, Schweizer D. Neuronal current imaging: An experimental method to investigate electrical currents in dogs with idiopathic epilepsy. J Vet Intern Med 2021; 35:2828-2836. [PMID: 34623697 PMCID: PMC8692176 DOI: 10.1111/jvim.16270] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Revised: 09/04/2021] [Accepted: 09/10/2021] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND The diagnosis of idiopathic epilepsy (IE) in dogs is based on exclusion of other potential causes of seizures. Recently, a novel magnetic resonance imaging (MRI) sequence that utilizes a variant of the rotary saturation approach has been suggested to detect weak transient magnetic field oscillations generated by neuronal currents in humans with epilepsy. HYPOTHESIS/OBJECTIVES Effects on the magnetic field evoked by intrinsic epileptic activity can be detected by MRI in the canine brain. As proof-of-concept, the novel MRI sequence to detect neuronal currents was applied in dogs. ANIMALS Twelve dogs with IE and 5 control dogs without a history of epileptic seizures were examined. METHODS Prospective case-control study as proof-of-concept. All dogs underwent a clinical neurological examination, scalp electroencephalography, cerebrospinal fluid analysis, and MRI. The MRI examination included a spin-locking (SL) experiment applying a low-power on-resonance radiofrequency pulse in a predefined frequency domain in the range of oscillations generated by the epileptogenic tissue. RESULTS In 11 of 12 dogs with IE, rotary saturation effects were detected by the MRI sequence. Four of 5 control dogs did not show rotary saturation effects. One control dog with a diagnosis of neuronal ceroid lipofuscinosis had SL-related effects, but did not have epileptic seizures clinically. CONCLUSIONS AND CLINICAL IMPORTANCE The proposed MRI method detected neuronal currents in dogs with epileptic seizures and represents a potential new line of research to investigate neuronal currents possibly related to IE in dogs.
Collapse
Affiliation(s)
- Daniela M Unger
- Division of Clinical Radiology, Department of Clinical Veterinary Medicine, Vetsuisse Faculty, University of Bern, Bern, Switzerland
| | - Roland Wiest
- Support Center of Advanced Neuroimaging (SCAN), Institute of Diagnostic and Interventional Neuroradiology, Inselspital Bern, University of Bern, Bern, Switzerland
| | - Claus Kiefer
- Support Center of Advanced Neuroimaging (SCAN), Institute of Diagnostic and Interventional Neuroradiology, Inselspital Bern, University of Bern, Bern, Switzerland
| | - Mathieu Raillard
- Division of Clinical Anesthesiology, Department of Clinical Veterinary Medicine, Vetsuisse Faculty, University of Bern, Bern, Switzerland
| | - Guillaume F Dutil
- Division of Clinical Neurology, Department of Clinical Veterinary Medicine, Vetsuisse Faculty, University of Bern, Bern, Switzerland
| | - Veronika M Stein
- Division of Clinical Neurology, Department of Clinical Veterinary Medicine, Vetsuisse Faculty, University of Bern, Bern, Switzerland
| | - Daniela Schweizer
- Division of Clinical Radiology, Department of Clinical Veterinary Medicine, Vetsuisse Faculty, University of Bern, Bern, Switzerland
| |
Collapse
|
48
|
Yedavalli V, DiGiacomo P, Tong E, Zeineh M. High-resolution Structural Magnetic Resonance Imaging and Quantitative Susceptibility Mapping. Magn Reson Imaging Clin N Am 2021; 29:13-39. [PMID: 33237013 DOI: 10.1016/j.mric.2020.09.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
High-resolution 7-T imaging and quantitative susceptibility mapping produce greater anatomic detail compared with conventional strengths because of improvements in signal/noise ratio and contrast. The exquisite anatomic details of deep structures, including delineation of microscopic architecture using advanced techniques such as quantitative susceptibility mapping, allows improved detection of abnormal findings thought to be imperceptible on clinical strengths. This article reviews caveats and techniques for translating sequences commonly used on 1.5 or 3 T to high-resolution 7-T imaging. It discusses for several broad disease categories how high-resolution 7-T imaging can advance the understanding of various diseases, improve diagnosis, and guide management.
Collapse
Affiliation(s)
- Vivek Yedavalli
- Department of Radiology, Stanford University, 300 Pasteur Drive, Room S047, Stanford, CA 94305-5105, USA; Division of Neuroradiology, Johns Hopkins University, 600 N. Wolfe St. B-112 D, Baltimore, MD 21287, USA
| | - Phillip DiGiacomo
- Department of Bioengineering, Stanford University, Lucas Center for Imaging, Room P271, 1201 Welch Road, Stanford, CA 94305-5488, USA
| | - Elizabeth Tong
- Department of Radiology, 300 Pasteur Drive, Room S031, Stanford, CA 94305-5105, USA
| | - Michael Zeineh
- Department of Radiology, Stanford University, Lucas Center for Imaging, Room P271, 1201 Welch Road, Stanford, CA 94305-5488, USA.
| |
Collapse
|
49
|
Oliveira ÍAF, Roos T, Dumoulin SO, Siero JCW, van der Zwaag W. Can 7T MPRAGE match MP2RAGE for gray-white matter contrast? Neuroimage 2021; 240:118384. [PMID: 34265419 DOI: 10.1016/j.neuroimage.2021.118384] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 06/25/2021] [Accepted: 07/08/2021] [Indexed: 10/20/2022] Open
Abstract
Ultra-High Field (UHF) MRI provides a significant increase in Signal-to-Noise Ratio (SNR) and gains in contrast weighting in several functional and structural acquisitions. Unfortunately, an increase in field strength also induces non-uniformities in the transmit field (B1+) that can compromise image contrast non-uniformly. The MPRAGE is one of the most common T1 weighted (T1w) image acquisitions for structural imaging. It provides excellent contrast between gray and white matter and is widely used for brain segmentation. At 7T, the signal non-uniformities tend to complicate this and therefore, the self-bias-field corrected MP2RAGE is often used there. In both MPRAGE and MP2RAGE, more homogeneous image contrast can be achieved with adiabatic pulses, like the TR-FOCI inversion pulse, or special pulse design on parallel transmission systems, like Universal Pulses (UP). In the present study, we investigate different strategies to improve the bias-field for MPRAGE at 7T, comparing the contrast and GM/WM segmentability against MP2RAGE. The higher temporal efficiency of MPRAGE combined with the potential of the user-friendly UPs was the primary motivation for this MPRAGE-MP2RAGE comparison. We acquired MPRAGE data in six volunteers, adding a k-space shutter to reduce scan time, a kt-point UP approach for homogeneous signal excitation, and a TR-FOCI pulse for homogeneous inversion. Our results show remarkable signal contrast improvement throughout the brain, including regions of low B1+ such as the cerebellum. The improvements in the MPRAGE were largest following the introduction of the UPs. In addition to the CNR, both SNR and GM/WM segmentability were also assessed. Among the MPRAGEs, the combined strategy (UP + TR-FOCI) yielded highest SNR and showed highest spatial similarity between GM segments to the MP2RAGE. Interestingly, the distance between gray and white matter peaks in the intensity histograms did not increase, as better pulses and higher SNR especially benefitted the (cerebellar) gray matter. Overall, the gray-white matter contrast from MP2RAGE is higher, with higher CNR and higher intensity peak distances, even when scaled to scan time. Hence, the extra acquisition time for MP2RAGE is justified by the improved segmentability.
Collapse
Affiliation(s)
- Ícaro A F Oliveira
- Spinoza Centre for Neuroimaging, Amsterdam, the Netherlands; Experimental and Applied Psychology, VU University, Amsterdam, the Netherlands.
| | - Thomas Roos
- Spinoza Centre for Neuroimaging, Amsterdam, the Netherlands
| | - Serge O Dumoulin
- Spinoza Centre for Neuroimaging, Amsterdam, the Netherlands; Experimental and Applied Psychology, VU University, Amsterdam, the Netherlands; Experimental Psychology, Helmholtz Institute, Utrecht University, Utrecht, the Netherlands
| | - Jeroen C W Siero
- Spinoza Centre for Neuroimaging, Amsterdam, the Netherlands; Radiology, Utrecht Center for Image Sciences, University Medical Center Utrecht, Utrecht, the Netherlands
| | | |
Collapse
|
50
|
Zong X, Nanavati S, Hung SC, Li T, Lin W. Effects of motion and retrospective motion correction on the visualization and quantification of perivascular spaces in ultrahigh resolution T2-weighted images at 7T. Magn Reson Med 2021; 86:1944-1955. [PMID: 34009709 DOI: 10.1002/mrm.28847] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 04/24/2021] [Accepted: 04/26/2021] [Indexed: 11/06/2022]
Abstract
PURPOSE Motion can strongly affect MRI image quality and derived imaging measures. We studied the effects of motion and retrospective motion correction (MC) on the visualization and quantitative measures of the perivascular space and penetrating vessel (PVSV) complex, an essential part of the glymphatic system, on high-resolution T2 -weighted MRI images at 7T. METHODS MC was achieved by adjusting k-space data based on head positions measured using fat navigator images. PVSV visibility and quantitative measures including diameter, volume fraction (VF), count, and contrast were compared between images with and without MC. RESULTS Without MC, VF, and count decreased significantly with increasing head rotation. MC improved PVSV visualization in all cases with severe motion artifacts. MC decreased diameter in white matter (WM) and increased VF, count, and contrast in basal ganglia and WM. The changes of VF, count, and contrast after MC strongly correlated with motion severity. MC eliminated the significant dependences of VF and count on rotation and reduced the inter-subject variations of VF and count. The effect sizes of age and breathing gas effects on VF and count, and contrast increased in most cases after MC, while those on diameter exhibited inconsistent behavior. CONCLUSIONS Motion affects PVSV quantification without MC. MC improves PVSV visibility and increases the statistical power of detecting physiological PVSV VF, count, and contrast changes but may have limited benefits for increasing the power for detecting diameter changes.
Collapse
Affiliation(s)
- Xiaopeng Zong
- Department of Radiology, University of North Carolina, Chapel Hill, North Carolina, USA.,Biomedical Research Imaging Center, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Soham Nanavati
- Department of Statistics and Operations Research, University of North Carolina, Chapel Hill, North Carolina, USA.,Department of Biology, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Sheng-Che Hung
- Department of Radiology, University of North Carolina, Chapel Hill, North Carolina, USA.,Biomedical Research Imaging Center, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Tengfei Li
- Department of Radiology, University of North Carolina, Chapel Hill, North Carolina, USA.,Biomedical Research Imaging Center, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Weili Lin
- Department of Radiology, University of North Carolina, Chapel Hill, North Carolina, USA.,Biomedical Research Imaging Center, University of North Carolina, Chapel Hill, North Carolina, USA
| |
Collapse
|