1
|
Ahookhosh K, Vanoirbeek J, Vande Velde G. Lung function measurements in preclinical research: What has been done and where is it headed? Front Physiol 2023; 14:1130096. [PMID: 37035677 PMCID: PMC10073442 DOI: 10.3389/fphys.2023.1130096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Accepted: 03/10/2023] [Indexed: 04/11/2023] Open
Abstract
Due to the close interaction of lung morphology and functions, repeatable measurements of pulmonary function during longitudinal studies on lung pathophysiology and treatment efficacy have been a great area of interest for lung researchers. Spirometry, as a simple and quick procedure that depends on the maximal inspiration of the patient, is the most common lung function test in clinics that measures lung volumes against time. Similarly, in the preclinical area, plethysmography techniques offer lung functional parameters related to lung volumes. In the past few decades, many innovative techniques have been introduced for in vivo lung function measurements, while each one of these techniques has their own advantages and disadvantages. Before each experiment, depending on the sensitivity of the required pulmonary functional parameters, it should be decided whether an invasive or non-invasive approach is desired. On one hand, invasive techniques offer sensitive and specific readouts related to lung mechanics in anesthetized and tracheotomized animals at endpoints. On the other hand, non-invasive techniques allow repeatable lung function measurements in conscious, free-breathing animals with readouts related to the lung volumes. The biggest disadvantage of these standard techniques for lung function measurements is considering the lung as a single unit and providing only global readouts. However, recent advances in lung imaging modalities such as x-ray computed tomography and magnetic resonance imaging opened new doors toward obtaining both anatomical and functional information from the same scan session, without the requirement for any extra pulmonary functional measurements, in more regional and non-invasive manners. Consequently, a new field of study called pulmonary functional imaging was born which focuses on introducing new techniques for regional quantification of lung function non-invasively using imaging-based techniques. This narrative review provides first an overview of both invasive and non-invasive conventional methods for lung function measurements, mostly focused on small animals for preclinical research, including discussions about their advantages and disadvantages. Then, we focus on those newly developed, non-invasive, imaging-based techniques that can provide either global or regional lung functional readouts at multiple time-points.
Collapse
Affiliation(s)
- Kaveh Ahookhosh
- Biomedical MRI, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
| | - Jeroen Vanoirbeek
- Centre of Environment and Health, Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium
| | - Greetje Vande Velde
- Biomedical MRI, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
- *Correspondence: Greetje Vande Velde,
| |
Collapse
|
2
|
Asosingh K, Frimel M, Zlojutro V, Grant D, Stephens O, Wenger D, Fouras A, DiFilippo F, Erzurum S. Preclinical Four-Dimensional Functional Lung Imaging and Quantification of Regional Airflow: A New Standard in Lung Function Evaluation in Murine Models. Am J Respir Cell Mol Biol 2022; 67:423-429. [PMID: 35687482 PMCID: PMC9564925 DOI: 10.1165/rcmb.2022-0055ma] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Accepted: 06/10/2022] [Indexed: 02/06/2023] Open
Abstract
The current standard for lung function evaluation in murine models is based on forced oscillation technology, which provides a measure of the total airway function but cannot provide information on regional heterogeneity in function. Limited detection of regional airflow may contribute to a discontinuity between airway inflammation and airflow obstruction in models of asthma. Here, we describe quantification of regional airway function using novel dynamic quantitative imaging and analysis to quantify and visualize lung motion and regional pulmonary airflow in four dimensions (4D). Furthermore, temporo-spatial specific ventilation (ml/ml) is used to determine ventilation heterogeneity indices for lobar and sublobar regions, which are directly compared to ex vivo biological analyses in the same sublobar regions. In contrast, oscillation-based technology in murine genetic models of asthma have failed to demonstrate lung function change despite altered inflammation, whereas 4D functional lung imaging demonstrated diminished regional lung function in genetic models relative to wild-type mice. Quantitative functional lung imaging assists in localizing the regional effects of airflow. Our approach reveals repeatable and consistent differences in regional airflow between lung lobes in all models of asthma, suggesting that asthma is characterized by regional airway dysfunctions that are often not detectable in composite measures of lung function. 4D functional lung imaging technology has the potential to transform discovery and development in murine models by mapping out regional areas heterogeneously affected by the disease, thus deciphering pathobiology with greater precision.
Collapse
Affiliation(s)
- Kewal Asosingh
- Department of Inflammation and Immunity Lerner Research Institute and Respiratory Institute and
| | - Matthew Frimel
- Department of Inflammation and Immunity Lerner Research Institute and Respiratory Institute and
| | - Violetta Zlojutro
- Department of Inflammation and Immunity Lerner Research Institute and Respiratory Institute and
| | - Dillon Grant
- Department of Inflammation and Immunity Lerner Research Institute and Respiratory Institute and
| | | | - David Wenger
- 4DMedical Research and Development, Los Angeles, California
| | - Andreas Fouras
- 4DMedical Research and Development, Los Angeles, California
| | | | - Serpil Erzurum
- Department of Inflammation and Immunity Lerner Research Institute and Respiratory Institute and
- Cleveland Clinic, Cleveland, Ohio; and
| |
Collapse
|
3
|
Oliveira MA, Lino-Alvarado AE, Moriya HT, Vitorasso RL. Drug class effects on respiratory mechanics in animal models: access and applications. Exp Biol Med (Maywood) 2021; 246:1094-1103. [PMID: 33601911 DOI: 10.1177/1535370221993095] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Assessment of respiratory mechanics extends from basic research and animal modeling to clinical applications in humans. However, to employ the applications in human models, it is desirable and sometimes mandatory to study non-human animals first. To acquire further precise and controlled signals and parameters, the animals studied must be further distant from their spontaneous ventilation. The majority of respiratory mechanics studies use positive pressure ventilation to model the respiratory system. In this scenario, a few drug categories become relevant: anesthetics, muscle blockers, bronchoconstrictors, and bronchodilators. Hence, the main objective of this study is to briefly review and discuss each drug category, and the impact of a drug on the assessment of respiratory mechanics. Before and during the positive pressure ventilation, the experimental animal must be appropriately sedated and anesthetized. The sedation will lower the pain and distress of the studied animal and the plane of anesthesia will prevent the pain. With those drugs, a more controlled procedure is carried out; further, because many anesthetics depress the respiratory system activity, a minimum interference of the animal's respiration efforts are achieved. The latter phenomenon is related to muscle blockers, which aim to minimize respiratory artifacts that may interfere with forced oscillation techniques. Generally, the respiratory mechanics are studied under appropriate anesthesia and muscle blockage. The application of bronchoconstrictors is prevalent in respiratory mechanics studies. To verify the differences among studied groups, it is often necessary to challenge the respiratory system, for example, by pharmacologically inducing bronchoconstriction. However, the selected bronchoconstrictor, doses, and administration can affect the evaluation of respiratory mechanics. Although not prevalent, studies have applied bronchodilators to return (airway resistance) to the basal state after bronchoconstriction. The drug categories can influence the mathematical modeling of the respiratory system, systemic conditions, and respiratory mechanics outcomes.
Collapse
Affiliation(s)
- Maria A Oliveira
- Department of Pharmacology, Institute of Biomedical Science, University of Sao Paulo (USP) Sao Paulo, SP 05508-000, Brazil
| | - Alembert E Lino-Alvarado
- Biomedical Engineering Laboratory - University of Sao Paulo (USP) Sao Paulo, SP 05508-010, Brazil
| | - Henrique T Moriya
- Biomedical Engineering Laboratory - University of Sao Paulo (USP) Sao Paulo, SP 05508-010, Brazil
| | - Renato L Vitorasso
- Biomedical Engineering Laboratory - University of Sao Paulo (USP) Sao Paulo, SP 05508-010, Brazil
| |
Collapse
|
4
|
Vitorasso RDL, de Oliveira MA, Tavares-de-Lima W, Moriya HT. Respiratory mechanics evaluation of mice submitted to intravenous methacholine: Bolus vs. continuous infusion. Exp Biol Med (Maywood) 2020; 245:680-689. [PMID: 32183551 DOI: 10.1177/1535370220912393] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
Abstract
IMPACT STATEMENT Respiratory mechanics studies are associated with fundamental research and translational studies; the present work thus investigates this particular matter. Our current research describes differences and similarities between two different ways of administrating a very prevalent bronchoconstrictor (methacholine) in an aging process scenario. The core issue of our work is related with troubles we find with the bolus protocol and the application of the mathematical model used to assess the respiratory mechanics. Our findings reveal the continuous infusion as an alternative to these problems and we hope to provide the proper foundations to a more reliable assessment in the respiratory field.
Collapse
Affiliation(s)
- Renato de L Vitorasso
- Biomedical Engineering Laboratory, University of Sao Paulo (USP), Sao Paulo 05508-010, Brazil
| | - Maria A de Oliveira
- Department of Pharmacology, Institute of Biomedical Science USP, Sao Paulo 05508-000, Brazil
| | - Wothan Tavares-de-Lima
- Department of Pharmacology, Institute of Biomedical Science USP, Sao Paulo 05508-000, Brazil
| | - Henrique T Moriya
- Biomedical Engineering Laboratory, University of Sao Paulo (USP), Sao Paulo 05508-010, Brazil
| |
Collapse
|
5
|
Valenga MH, Vitorasso RDL, Rodrigues TG, Pazetti R, Cardoso PFG, Moriya HT, Aoki FG. An in vivo image acquisition system for the evaluation of tracheal mechanics in rats. Artif Organs 2019; 44:504-512. [PMID: 31715014 DOI: 10.1111/aor.13604] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2019] [Revised: 10/30/2019] [Accepted: 11/04/2019] [Indexed: 12/27/2022]
Abstract
Mechanical evaluation of tracheal grafts is of great relevance for transplant research. Although there are some publications demonstrating different techniques of tracheal mechanical evaluation, there is still no definitive or preferred protocol available. Here, we present a simple image processing acquisition system that can be used for in vivo experiments. Six male Wistar rats were submitted to orotracheal intubation and a longitudinal incision was made to expose the trachea. Images of tracheae were acquired from a video camera in different scenarios of bronchoconstriction using methacholine (MCh) (Basal, PBS, MCh 30 μg/kg, MCh 300 μg/kg, and postmetabolized) during imposed-inspiration and imposed-expiration. The area variation ratio (the ratio between areas during expiration vs. inspiration) was 1.1× for the Basal group, while the ratio for MCh 300 µg/kg was 6.5×. The area variation of imaged tracheae was statistically significant at the dose of MCh 300 µg/kg for imposed-inspiration versus imposed-expiration (P = .002). Likewise, elastance data of respiratory mechanics indicated a statistically significant difference at the dose of MCh 300 µg/kg for imposed-inspiration versus imposed-expiration (P = .026). Our image processing analysis protocol presented corresponding behavior when compared to mechanical parameters of the respiratory system. In addition, our image acquisition system was able to highlight the differences between imposed-inspiration and imposed-expiration. Image analysis of the tracheal area variation seems to be in agreement with the elastance of the respiratory system. Taken together, these observations may help future studies of tracheal transplantation for in situ assessment of graft patency.
Collapse
Affiliation(s)
- Marcelo Henrique Valenga
- Biomedical Engineering Laboratory (LEB), Escola Politécnica, University of São Paulo, São Paulo - SP, Brazil
| | - Renato de Lima Vitorasso
- Biomedical Engineering Laboratory (LEB), Escola Politécnica, University of São Paulo, São Paulo - SP, Brazil
| | - Thiago Guimarães Rodrigues
- Biomedical Engineering Laboratory (LEB), Escola Politécnica, University of São Paulo, São Paulo - SP, Brazil
| | - Rogério Pazetti
- Thoracic Surgery Research Laboratory (LIM-61), Instituto do Coração (InCor), University of São Paulo, São Paulo - SP, Brazil
| | | | - Henrique Takachi Moriya
- Biomedical Engineering Laboratory (LEB), Escola Politécnica, University of São Paulo, São Paulo - SP, Brazil
| | - Fabio Gava Aoki
- Biomedical Engineering Laboratory (LEB), Escola Politécnica, University of São Paulo, São Paulo - SP, Brazil.,Institute of Science and Technology (ICT), Federal University of São Paulo, São José dos Campos - SP, Brazil
| |
Collapse
|
6
|
Virgincar RS, Dahlke J, Robertson SH, Morand N, Qi Y, Degan S, Driehuys B, Nouls JC. A portable ventilator with integrated physiologic monitoring for hyperpolarized 129Xe MRI in rodents. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2018; 295:63-71. [PMID: 30125865 PMCID: PMC6719309 DOI: 10.1016/j.jmr.2018.07.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2018] [Revised: 07/13/2018] [Accepted: 07/21/2018] [Indexed: 05/09/2023]
Abstract
Hyperpolarized (HP) 129Xe MRI is emerging as a powerful, non-invasive method to image lung function and is beginning to find clinical application across a range of conditions. As clinical implementation progresses, it becomes important to translate back to well-defined animal models, where novel disease signatures can be characterized longitudinally and validated against histology. To date, preclinical 129Xe MRI has been limited to only a few sites worldwide with 2D imaging that is not generally sufficient to fully capture the heterogeneity of lung disease. To address these limitations and facilitate broader dissemination, we report on a compact and portable HP gas ventilator that integrates all the gas-delivery and physiologic monitoring capabilities required for high-resolution 3D hyperpolarized 129Xe imaging. This ventilator is MR- and HP-gas compatible, driven by inexpensive microcontrollers and open source code, and allows for precise control of the tidal volume and breathing cycle in perorally intubated mice and rats. We use the system to demonstrate data acquisition over multiple breath-holds, during which lung motion is suspended to enable high-resolution 3D imaging of gas-phase and dissolved-phase 129Xe in the lungs. We demonstrate the portability and versatility of the ventilator by imaging a mouse model of lung cancer longitudinally at 2 Tesla, and a healthy rat at 7 Tesla. We also report the detection of subtle spectroscopic fluctuations in phase with the heart rate, superimposed onto larger variations stemming from the respiratory cycle. This ventilator was developed to facilitate duplication and gain broad adoption to accelerate preclinical 129Xe MRI research.
Collapse
Affiliation(s)
| | - Jerry Dahlke
- Radiology, Duke University Medical Center, Durham, NC, USA
| | | | | | - Yi Qi
- Radiology, Duke University Medical Center, Durham, NC, USA
| | - Simone Degan
- Radiology, Duke University Medical Center, Durham, NC, USA
| | - Bastiaan Driehuys
- Biomedical Engineering, Duke University, Durham, NC, USA; Radiology, Duke University Medical Center, Durham, NC, USA; Medical Physics Graduate Program, Duke University, Durham, NC, USA
| | - John C Nouls
- Radiology, Duke University Medical Center, Durham, NC, USA.
| |
Collapse
|
7
|
Adamson EB, Ludwig KD, Mummy DG, Fain SB. Magnetic resonance imaging with hyperpolarized agents: methods and applications. Phys Med Biol 2017; 62:R81-R123. [PMID: 28384123 DOI: 10.1088/1361-6560/aa6be8] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
In the past decade, hyperpolarized (HP) contrast agents have been under active development for MRI applications to address the twin challenges of functional and quantitative imaging. Both HP helium (3He) and xenon (129Xe) gases have reached the stage where they are under study in clinical research. HP 129Xe, in particular, is poised for larger scale clinical research to investigate asthma, chronic obstructive pulmonary disease, and fibrotic lung diseases. With advances in polarizer technology and unique capabilities for imaging of 129Xe gas exchange into lung tissue and blood, HP 129Xe MRI is attracting new attention. In parallel, HP 13C and 15N MRI methods have steadily advanced in a wide range of pre-clinical research applications for imaging metabolism in various cancers and cardiac disease. The HP [1-13C] pyruvate MRI technique, in particular, has undergone phase I trials in prostate cancer and is poised for investigational new drug trials at multiple institutions in cancer and cardiac applications. This review treats the methodology behind both HP gases and HP 13C and 15N liquid state agents. Gas and liquid phase HP agents share similar technologies for achieving non-equilibrium polarization outside the field of the MRI scanner, strategies for image data acquisition, and translational challenges in moving from pre-clinical to clinical research. To cover the wide array of methods and applications, this review is organized by numerical section into (1) a brief introduction, (2) the physical and biological properties of the most common polarized agents with a brief summary of applications and methods of polarization, (3) methods for image acquisition and reconstruction specific to improving data acquisition efficiency for HP MRI, (4) the main physical properties that enable unique measures of physiology or metabolic pathways, followed by a more detailed review of the literature describing the use of HP agents to study: (5) metabolic pathways in cancer and cardiac disease and (6) lung function in both pre-clinical and clinical research studies, concluding with (7) some future directions and challenges, and (8) an overall summary.
Collapse
Affiliation(s)
- Erin B Adamson
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, United States of America
| | | | | | | |
Collapse
|
8
|
House JS, Nichols CE, Li H, Brandenberger C, Virgincar RS, DeGraff LM, Driehuys B, Zeldin DC, London SJ. Vagal innervation is required for pulmonary function phenotype in Htr4-/- mice. Am J Physiol Lung Cell Mol Physiol 2017; 312:L520-L530. [PMID: 28130264 PMCID: PMC5407097 DOI: 10.1152/ajplung.00495.2016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2016] [Revised: 01/19/2017] [Accepted: 01/25/2017] [Indexed: 11/22/2022] Open
Abstract
Human genome-wide association studies have identified over 50 loci associated with pulmonary function and related phenotypes, yet follow-up studies to determine causal genes or variants are rare. Single nucleotide polymorphisms in serotonin receptor 4 (HTR4) are associated with human pulmonary function in genome-wide association studies and follow-up animal work has demonstrated that Htr4 is causally associated with pulmonary function in mice, although the precise mechanisms were not identified. We sought to elucidate the role of neural innervation and pulmonary architecture in the lung phenotype of Htr4-/- animals. We report here that the Htr4-/- phenotype in mouse is dependent on vagal innervation to the lung. Both ex vivo tracheal ring reactivity and in vivo flexiVent pulmonary functional analyses demonstrate that vagotomy abrogates the Htr4-/- airway hyperresponsiveness phenotype. Hyperpolarized 3He gas magnetic resonance imaging and stereological assessment of wild-type and Htr4-/- mice reveal no observable differences in lung volume, inflation characteristics, or pulmonary microarchitecture. Finally, control of breathing experiments reveal substantive differences in baseline breathing characteristics between mice with/without functional HTR4 in breathing frequency, relaxation time, flow rate, minute volume, time of inspiration and expiration and breathing pauses. These results suggest that HTR4's role in pulmonary function likely relates to neural innervation and control of breathing.
Collapse
Affiliation(s)
- John S House
- Immunity, Inflammation, and Disease Laboratory, National Institute of Environmental Health Sciences, Research Triangle Park, North Carolina
| | - Cody E Nichols
- Immunity, Inflammation, and Disease Laboratory, National Institute of Environmental Health Sciences, Research Triangle Park, North Carolina
| | - Huiling Li
- Immunity, Inflammation, and Disease Laboratory, National Institute of Environmental Health Sciences, Research Triangle Park, North Carolina
| | | | - Rohan S Virgincar
- Center for In Vivo Microscopy, Duke University Medical Center, Durham, North Carolina.,Biomedical Engineering, Duke University, Durham, North Carolina
| | - Laura M DeGraff
- Immunity, Inflammation, and Disease Laboratory, National Institute of Environmental Health Sciences, Research Triangle Park, North Carolina
| | - Bastiaan Driehuys
- Center for In Vivo Microscopy, Duke University Medical Center, Durham, North Carolina.,Biomedical Engineering, Duke University, Durham, North Carolina.,Radiology, Duke University Medical Center, Durham, North Carolina; and
| | - Darryl C Zeldin
- Immunity, Inflammation, and Disease Laboratory, National Institute of Environmental Health Sciences, Research Triangle Park, North Carolina
| | - Stephanie J London
- Immunity, Inflammation, and Disease Laboratory, National Institute of Environmental Health Sciences, Research Triangle Park, North Carolina; .,Epidemiology Branch, National Institute of Environmental Health Sciences, Research Triangle Park, North Carolina
| |
Collapse
|
9
|
Lilburn DML, Tatler AL, Six JS, Lesbats C, Habgood A, Porte J, Hughes-Riley T, Shaw DE, Jenkins G, Meersmann T. Investigating lung responses with functional hyperpolarized xenon-129 MRI in an ex vivo rat model of asthma. Magn Reson Med 2016; 76:1224-35. [PMID: 26507239 PMCID: PMC5026173 DOI: 10.1002/mrm.26003] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2015] [Revised: 08/26/2015] [Accepted: 09/08/2015] [Indexed: 01/08/2023]
Abstract
PURPOSE Asthma is a disease of increasing worldwide importance that calls for new investigative methods. Ex vivo lung tissue is being increasingly used to study functional respiratory parameters independent of confounding systemic considerations but also to reduce animal numbers and associated research costs. In this work, a straightforward laboratory method is advanced to probe dynamic changes in gas inhalation patterns by using an ex vivo small animal ovalbumin (OVA) model of human asthma. METHODS Hyperpolarized (hp) (129) Xe was actively inhaled by the excised lungs exposed to a constant pressure differential that mimicked negative pleural cavity pressure. The method enabled hp (129) Xe MRI of airway responsiveness to intravenous methacholine (MCh) and airway challenge reversal through salbutamol. RESULTS Significant differences were demonstrated between control and OVA challenged animals on global lung hp (129) Xe gas inhalation with P < 0.05 at MCh dosages above 460 μg. Spatial mapping of the regional hp gas distribution revealed an approximately three-fold increase in heterogeneity for the asthma model organs. CONCLUSION The experimental results from this proof of concept work suggest that the ex vivo hp noble gas imaging arrangement and the applied image analysis methodology may be useful as an adjunct to current diagnostic techniques. Magn Reson Med 76:1224-1235, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Collapse
Affiliation(s)
- David M L Lilburn
- Sir Peter Mansfield Imaging Centre, School of Medicine, University of Nottingham, Nottingham, United Kingdom
| | - Amanda L Tatler
- Division of Respiratory Medicine, Nottingham University Hospitals, City Campus, University of Nottingham, Nottingham, United Kingdom
| | - Joseph S Six
- Sir Peter Mansfield Imaging Centre, School of Medicine, University of Nottingham, Nottingham, United Kingdom
| | - Clémentine Lesbats
- Sir Peter Mansfield Imaging Centre, School of Medicine, University of Nottingham, Nottingham, United Kingdom
| | - Anthony Habgood
- Division of Respiratory Medicine, Nottingham University Hospitals, City Campus, University of Nottingham, Nottingham, United Kingdom
| | - Joanne Porte
- Division of Respiratory Medicine, Nottingham University Hospitals, City Campus, University of Nottingham, Nottingham, United Kingdom
| | - Theodore Hughes-Riley
- Sir Peter Mansfield Imaging Centre, School of Medicine, University of Nottingham, Nottingham, United Kingdom
| | - Dominick E Shaw
- Division of Respiratory Medicine, Nottingham University Hospitals, City Campus, University of Nottingham, Nottingham, United Kingdom
| | - Gisli Jenkins
- Division of Respiratory Medicine, Nottingham University Hospitals, City Campus, University of Nottingham, Nottingham, United Kingdom
| | - Thomas Meersmann
- Sir Peter Mansfield Imaging Centre, School of Medicine, University of Nottingham, Nottingham, United Kingdom.
| |
Collapse
|
10
|
Thomas AC, Potts EN, Chen BT, Slipetz DM, Foster WM, Driehuys B. A robust protocol for regional evaluation of methacholine challenge in mouse models of allergic asthma using hyperpolarized (3)He MRI. NMR IN BIOMEDICINE 2015; 28:1185. [PMID: 26174861 DOI: 10.1002/nbm.3365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
|
11
|
Ruppert K. Biomedical imaging with hyperpolarized noble gases. REPORTS ON PROGRESS IN PHYSICS. PHYSICAL SOCIETY (GREAT BRITAIN) 2014; 77:116701. [PMID: 25360484 DOI: 10.1088/0034-4885/77/11/116701] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Hyperpolarized noble gases (HNGs), polarized to approximately 50% or higher, have led to major advances in magnetic resonance (MR) imaging of porous structures and air-filled cavities in human subjects, particularly the lung. By boosting the available signal to a level about 100 000 times higher than that at thermal equilibrium, air spaces that would otherwise appear as signal voids in an MR image can be revealed for structural and functional assessments. This review discusses how HNG MR imaging differs from conventional proton MR imaging, how MR pulse sequence design is affected and how the properties of gas imaging can be exploited to obtain hitherto inaccessible information in humans and animals. Current and possible future imaging techniques, and their application in the assessment of normal lung function as well as certain lung diseases, are described.
Collapse
|
12
|
|
13
|
Bianchi A, Ozier A, Ousova O, Raffard G, Crémillieux Y. Ultrashort-TE MRI longitudinal study and characterization of a chronic model of asthma in mice: inflammation and bronchial remodeling assessment. NMR IN BIOMEDICINE 2013; 26:1451-1459. [PMID: 23761222 DOI: 10.1002/nbm.2975] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2012] [Revised: 04/15/2013] [Accepted: 04/16/2013] [Indexed: 06/02/2023]
Abstract
Asthma is a chronic disease characterized by bronchial hyperresponsiveness (BHR), bronchial inflammation and remodeling. The great improvements in (1)H MRI ultrashort-TE (UTE) sequences in the last decade have allowed lung images with high-resolution and good signal-to-noise ratio to be obtained in parenchymal tissues. In this article, we present a UTE (1)H MRI high-resolution study of a chronic model of asthma in mice with the aim to longitudinally assess the main features of asthma using a fully noninvasive approach. Balb/c mice (n = 6) were sensitized with ovalbumin over a period of 75 days. The control group (n = 3) received normal saline on the same days. MRI acquisitions were performed on days 0, 38 and 78 to study the inflammatory volumes and bronchial remodeling (peribronchial signal intensity index, PBSI). Plethysmographic studies were performed on days 0, 39 and 79 to assess BHR to methacholine using the enhanced pause (Penh) ratio. The average inflammatory volume measured by MRI in the ovalbumin group (15.6 ± 2.4 μL) was increased significantly relative to control mice (-0.3 ± 0.7 μL) on day 38. The inflammatory volume was larger (34.2 ± 3.1 μL) on day 78 in the ovalbumin group. PBSI was significantly higher in the ovalbumin group on day 78 (1.53 ± 0.08) relative to the control group (1.16 ± 0.10), but not on day 38. After sensitization, asthmatic mice presented BHR to methacholine on days 39 and 79. Penh ratios correlated significantly with the inflammatory volume on day 39 and with the PBSI on day 79. This study shows, for the first time, that high-resolution UTE (1)H MRI of the lungs may allow the noninvasive quantification of peribronchial eosinophilic inflammation with airways occlusion by mucus and of bronchial remodeling in a murine asthma model that correlates with functional parameters.
Collapse
Affiliation(s)
- Andrea Bianchi
- Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Université Bordeaux Segalen, Bordeaux, France; Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536, Université Bordeaux Segalen, Bordeaux, France
| | | | | | | | | |
Collapse
|
14
|
Wright D, Sharma P, Ryu MH, Rissé PA, Ngo M, Maarsingh H, Koziol-White C, Jha A, Halayko AJ, West AR. Models to study airway smooth muscle contraction in vivo, ex vivo and in vitro: implications in understanding asthma. Pulm Pharmacol Ther 2012; 26:24-36. [PMID: 22967819 DOI: 10.1016/j.pupt.2012.08.006] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2012] [Revised: 08/14/2012] [Accepted: 08/17/2012] [Indexed: 11/16/2022]
Abstract
Asthma is a chronic obstructive airway disease characterised by airway hyperresponsiveness (AHR) and airway wall remodelling. The effector of airway narrowing is the contraction of airway smooth muscle (ASM), yet the question of whether an inherent or acquired dysfunction in ASM contractile function plays a significant role in the disease pathophysiology remains contentious. The difficulty in determining the role of ASM lies in limitations with the models used to assess contraction. In vivo models provide a fully integrated physiological response but ASM contraction cannot be directly measured. Ex vivo and in vitro models can provide more direct assessment of ASM contraction but the loss of factors that may modulate ASM responsiveness and AHR, including interaction between multiple cell types and disruption of the mechanical environment, precludes a complete understanding of the disease process. In this review we detail key advantages of common in vivo, ex vivo and in vitro models of ASM contraction, as well as emerging tissue engineered models of ASM and whole airways. We also highlight important findings from each model with respect to the pathophysiology of asthma.
Collapse
Affiliation(s)
- David Wright
- Medical Research Council and Asthma UK Centre in Allergic Mechanisms of Asthma, King's College London, United Kingdom
| | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Thomas AC, Kaushik SS, Nouls J, Potts EN, Slipetz DM, Foster WM, Driehuys B. Effects of corticosteroid treatment on airway inflammation, mechanics, and hyperpolarized ³He magnetic resonance imaging in an allergic mouse model. J Appl Physiol (1985) 2012; 112:1437-44. [PMID: 22241062 PMCID: PMC3362235 DOI: 10.1152/japplphysiol.01293.2011] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2011] [Accepted: 01/10/2012] [Indexed: 11/22/2022] Open
Abstract
The purpose of this study was to assess the effects of corticosteroid therapy on a murine model of allergic asthma using hyperpolarized (3)He magnetic resonance imaging (MRI) and respiratory mechanics measurements before, during, and after methacholine (MCh) challenge. Three groups of mice were prepared, consisting of ovalbumin sensitized/ovalbumin challenged (Ova/Ova, n = 5), Ova/Ova challenged but treated with the corticosteroid dexamethasone (Ova/Ova+Dex, n = 3), and ovalbumin-sensitized/saline-challenged (Ova/PBS, n = 4) control animals. All mice underwent baseline 3D (3)He MRI, then received a MCh challenge while 10 2D (3)He MR images were acquired for 2 min, followed by post-MCh 3D (3)He MRI. Identically treated groups underwent respiratory mechanics evaluation (n = 4/group) and inflammatory cell counts (n = 4/group). Ova/Ova animals exhibited predominantly large whole lobar defects at baseline, with significantly higher ventilation defect percentage (VDP = 19 ± 4%) than Ova/PBS (+2 ± 1%, P = 0.01) animals. Such baseline defects were suppressed by dexamethasone (0%, P = 0.009). In the Ova/Ova group, MCh challenge increased VDP on both 2D (+30 ± 8%) and 3D MRI scans (+14 ± 2%). MCh-induced VDP changes were diminished in Ova/Ova+Dex animals on both 2D (+21 ± 9%, P = 0.63) and 3D scans (+7 ± 2%, P = 0.11) and also in Ova/PBS animals on 2D (+6 ± 3%, P = 0.07) and 3D (+4 ± 1%, P = 0.01) scans. Because MCh challenge caused near complete cessation of ventilation in four of five Ova/Ova animals, even as large airways remained patent, this implies that small airway (<188 μm) obstruction predominates in this model. This corresponds with respiratory mechanics observations that MCh challenge significantly increases elastance and tissue damping but only modestly affects Newtonian airway resistance.
Collapse
Affiliation(s)
- Abraham C Thomas
- Center for In Vivo Microscopy, Box 3302, Duke Univ. Medical Center, Durham, NC 27710, USA
| | | | | | | | | | | | | |
Collapse
|
16
|
Couch MJ, Ouriadov A, Santyr GE. Regional ventilation mapping of the rat lung using hyperpolarized129Xe magnetic resonance imaging. Magn Reson Med 2012; 68:1623-31. [DOI: 10.1002/mrm.24152] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2011] [Revised: 11/17/2011] [Accepted: 12/14/2011] [Indexed: 11/11/2022]
|
17
|
Risse F, Pesic J, Young S, Olsson LE. A texture analysis approach to quantify ventilation changes in hyperpolarised ³He MRI of the rat lung in an asthma model. NMR IN BIOMEDICINE 2012; 25:131-141. [PMID: 21739495 DOI: 10.1002/nbm.1725] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2010] [Revised: 03/17/2011] [Accepted: 03/17/2011] [Indexed: 05/31/2023]
Abstract
In preclinical research, allergic asthma is investigated in rats sensitised with the antigen ovalbumin (OVA), followed by a challenge with aerosolised OVA to induce an inflammatory reaction of the lower airways. This causes diffuse, nonfocal ventilation defects that lead to heterogeneously distributed signal intensities in hyperpolarised (HP) (3)He MR images, which are difficult to assess directly by diagnostic grading or volumetry. Texture analysis can characterise these changes and does not require segmentation of the lung structures prior to the analysis. The aim of this work was to evaluate a texture analysis approach to quantify changes in lung ventilation in HP (3)He MRI of OVA-challenged rats. OVA-challenged animals were treated with two different compound doses to evaluate the sensitivity of the texture analysis. Four groups were investigated using HP (3)He MRI at 4.7 T: controls, vehicle-treated, and low- and high-dose budesonide-treated rats. In addition, broncho-alveolar lavage was performed and the eosinophil cell count was used as a biological reference marker. First-order texture, geometrical features and features based on second-order statistics using run-length and grey-level co-occurrence matrices were calculated. In addition, wavelet transforms were applied to compute first-order statistics on multiple scales. The texture analysis was able to show significant differences between the control and untreated vehicle groups as well as between the vehicle and treatment groups. This is in agreement with the findings of the eosinophil cell counts, which were used as a marker for the severity of inflammation. However, not all features used in the different texture analysis methods could differentiate between the treatment groups. In conclusion, texture analysis can be used to quantify changes in lung ventilation as measured with HP (3)He MRI after therapeutic intervention with budesonide.
Collapse
Affiliation(s)
- Frank Risse
- DECS Imaging&Antibodies, AstraZeneca R&D, Mölndal, Sweden.
| | | | | | | |
Collapse
|
18
|
Mouse phenotyping with MRI. Methods Mol Biol 2011. [PMID: 21874500 DOI: 10.1007/978-1-61779-219-9_31] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
The field of mouse phenotyping with magnetic resonance imaging (MRI) is rapidly growing, motivated by the need for improved tools for characterizing and evaluating mouse models of human disease. Image results can provide important comparisons of human conditions with mouse disease models, evaluations of treatment, development or disease progression, as well as direction for histological or other investigations. Effective mouse MRI studies require attention to many aspects of experiment design. In this chapter, we provide details and discussion of important practical considerations: hardware requirements, mouse handling for in vivo imaging, specimen preparation for ex vivo imaging, sequence and contrast agent selection, study size, and quantitative image analysis. We focus particularly on anatomical phenotyping, an important and accessible application that has shown a high potential for impact in many mouse models at our imaging center.
Collapse
|
19
|
Nouls J, Fanarjian M, Hedlund L, Driehuys B. A Constant-Volume Ventilator and Gas Recapture System for Hyperpolarized Gas MRI of Mouse and Rat Lungs. CONCEPTS IN MAGNETIC RESONANCE. PART B, MAGNETIC RESONANCE ENGINEERING 2011; 39B:78-88. [PMID: 21625347 PMCID: PMC3103138 DOI: 10.1002/cmr.b.20192] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Affiliation(s)
- John Nouls
- Center for In Vivo Microscopy, Duke University Medical Center, Durham, NC
| | - Manuel Fanarjian
- Department of Biomedical Engineering, Duke University, Durham, NC
| | - Laurence Hedlund
- Center for In Vivo Microscopy, Duke University Medical Center, Durham, NC
| | - Bastiaan Driehuys
- Center for In Vivo Microscopy, Duke University Medical Center, Durham, NC
| |
Collapse
|
20
|
Zheng W, Cleveland ZI, Möller HE, Driehuys B. Gradient-induced longitudinal relaxation of hyperpolarized noble gases in the fringe fields of superconducting magnets used for magnetic resonance. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2011; 208:284-90. [PMID: 21134771 PMCID: PMC3026078 DOI: 10.1016/j.jmr.2010.11.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2010] [Revised: 11/09/2010] [Accepted: 11/09/2010] [Indexed: 05/09/2023]
Abstract
When hyperpolarized noble gases are brought into the bore of a superconducting magnet for magnetic resonance imaging (MRI) or spectroscopy studies, the gases must pass through substantial field gradients, which can cause rapid longitudinal relaxation. In this communication, we present a means of calculating this spatially dependent relaxation rate in the fringe field of typical magnets. We then compare these predictions to experimental measurements of (3)He relaxation at various positions near a medium-bore 2-T small animal MRI system. The calculated and measured relaxation rates on the central axis of the magnet agree well and show a maximum (3)He relaxation rate of 3.83×10(-3) s(-1) (T(1)=4.4 min) at a distance of 47 cm from the magnet isocenter. We also show that if this magnet were self-shielded, its minimum T(1) would drop to 1.2 min. In contrast, a typical self-shielded 1.5-T clinical MRI scanner will induce a minimum on-axis T(1) of 12 min. Additionally, we show that the cylindrically symmetric fields of these magnets enable gradient-induced relaxation to be calculated using only knowledge of the on-axis longitudinal field, which can either be measured directly or calculated from a simple field model. Thus, while most MRI magnets employ complex and proprietary current configurations, we show that their fringe fields and the resulting gradient-induced relaxation are well approximated by simple solenoid models. Finally, our modeling also demonstrates that relaxation rates can increase by nearly an order of magnitude at radial distances equivalent to the solenoid radius.
Collapse
Affiliation(s)
- Wangzhi Zheng
- Triangle Universities Nuclear Laboratory and Department of Physics, Duke University, Durham, NC 27708, USA
| | - Zackary I. Cleveland
- Center for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA
| | - Harald E. Möller
- Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Bastiaan Driehuys
- Center for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA
| |
Collapse
|
21
|
Mistry NN, Thomas A, Kaushik SS, Johnson GA, Driehuys B. Quantitative analysis of hyperpolarized 3He ventilation changes in mice challenged with methacholine. Magn Reson Med 2010; 63:658-66. [PMID: 20187176 DOI: 10.1002/mrm.22311] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The capability to use high-resolution (3)He MRI to depict regional ventilation changes and airway narrowing in mice challenged with methacholine (MCh) offers the opportunity to gain new insights into the study of asthma. However, to fully exploit the value of this novel technique, it is important to move beyond visual inspection of the images toward automated and quantitative analysis. To address this gap, we describe a postprocessing approach to create ventilation difference maps to better visualize and quantify regional ventilation changes before and after MCh challenge. We show that difference maps reveal subtle changes in airway caliber, and highlight both focal and diffuse regional alterations in ventilation. Ventilation changes include both hypoventilation and compensatory areas of hyperventilation. The difference maps can be quantified by a histogram plot of the ventilation changes, in which the standard deviation increases with MCh dose (R(2) = 0.89). This method of analysis is shown to be more sensitive than simple threshold-based detection of gross ventilation defects.
Collapse
Affiliation(s)
- Nilesh N Mistry
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27710, USA
| | | | | | | | | |
Collapse
|
22
|
Mosbah K, Stupar V, Berthezène Y, Beckmann N, Crémillieux Y. Spatially resolved assessment of serotonin-induced bronchoconstrictive responses in the rat lung using 3He ventilation MRI under spontaneous breathing conditions. Magn Reson Med 2010; 63:1669-74. [DOI: 10.1002/mrm.22391] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|