1
|
Mysegaes F, Spiteller P, Bernarding J, Plaumann M. 19 F VT NMR: Novel Tm 3+ and Ce 3+ Complexes Provide New Insight into Temperature Measurement Using Molecular Sensors. Chemphyschem 2023; 24:e202300057. [PMID: 37384817 DOI: 10.1002/cphc.202300057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Revised: 06/23/2023] [Accepted: 06/26/2023] [Indexed: 07/01/2023]
Abstract
In the past few decades, magnetic resonance spectroscopy (MRS) and MR imaging (MRI) have developed into a powerful non-invasive tool for medical diagnostic and therapy. Especially 19 F MR shows promising potential because of the properties of the fluorine atom and the negligible background signals in the MR spectra. The detection of temperature in a living organism is quite difficult, and usually external thermometers or fibers are used. Temperature determination via MRS needs temperature-sensitive contrast agents. This article reports first results of solvent and structural influences on the temperature sensitivity of 19 F NMR signals of chosen molecules. By using this chemical shift sensitivity, a local temperature can be determined with a high precision. Based on this preliminary study, we synthesized five metal complexes and compared the results of all variable temperature measurements. It is shown that the highest 19 F MR signal temperature dependence is detectable for a fluorine nucleus in a Tm3+ -complex.
Collapse
Affiliation(s)
- Felix Mysegaes
- University Bremen, Instrumental Analytics, Leobener Str. 7, 28359, Bremen, Germany
- Otto-von-Guericke University Magdeburg, Medical Faculty, Institute of Biometry and Medical Informatics, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Peter Spiteller
- University Bremen, Instrumental Analytics, Leobener Str. 7, 28359, Bremen, Germany
| | - Johannes Bernarding
- Otto-von-Guericke University Magdeburg, Medical Faculty, Institute of Biometry and Medical Informatics, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Markus Plaumann
- Otto-von-Guericke University Magdeburg, Medical Faculty, Institute of Biometry and Medical Informatics, Leipziger Str. 44, 39120, Magdeburg, Germany
| |
Collapse
|
2
|
Umegawa Y, Shimonishi T, Tsuchikawa H, Murata M. LnDOTA-d 8 , a versatile chemical-shift thermometer for 2 H solid-state NMR. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2022; 60:1005-1013. [PMID: 35938541 DOI: 10.1002/mrc.5303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 08/03/2022] [Accepted: 08/05/2022] [Indexed: 06/15/2023]
Abstract
2 H solid-state nuclear magnetic resonance (NMR) is a method for examining the mobility and orientation of molecules in the field of biophysics. In studies on lipid bilayer membranes, 2 H NMR is often adopted to detect a phase transition from the gel to the liquid-crystal phase, which is observed as a change in spectral shape, and to evaluate the ordering of lipid alkyl chains using quadrupole coupling values. Because the mobility of membrane lipids is highly temperature dependent, precise temperature control is a prerequisite for evaluating the physical properties of membranes. Generally, NMR instruments monitor the temperature of the variable temperature (VT) gas. The temperature inside the sample tube and the VT gas match only when the heat generated by the radio frequency (rf) pulse emitted from the coil or magic angle spinning is significantly lower than the cooling capacity of the VT gas. In other words, the sample temperature inside the tube depends on the measurement method. Therefore, in this study, we took advantage of temperature-dependent changes in the chemical shift of a paramagnetic metal-ligand complex. We designed and synthesized a deuterated ligand complex and evaluated its temperature dependence as a thermometer for 2 H solid-state NMR spectroscopy. We chose Tb, Dy, Ho, and Er as the paramagnetic central metals. We then measured the 2 H NMR spectrum of each metal complex and confirmed the 2 H chemical shift to be temperature dependent. Furthermore, with the use of the thermometer molecule with Er, we succeeded in accurately evaluating the segmental melting of an alkyl chain in lipid bilayers with 0.1°C accuracy.
Collapse
Affiliation(s)
- Yuichi Umegawa
- Department of Chemistry, Graduate School of Science, Osaka University, Osaka, Japan
- JST ERATO, Lipid Active Structure Project and Project Research Center for Fundamental Science, Osaka University, Osaka, Japan
| | - Takeshi Shimonishi
- Department of Chemistry, Graduate School of Science, Osaka University, Osaka, Japan
| | - Hiroshi Tsuchikawa
- Department of Chemistry, Graduate School of Science, Osaka University, Osaka, Japan
- Faculty of Medicine, Oita University, Yufu, Oita, Japan
| | - Michio Murata
- Department of Chemistry, Graduate School of Science, Osaka University, Osaka, Japan
- JST ERATO, Lipid Active Structure Project and Project Research Center for Fundamental Science, Osaka University, Osaka, Japan
| |
Collapse
|
3
|
Zakaria ABM, Huang Y, Coman D, Mishra SK, Mihailovic JM, Maritim S, Rojas-Quijano FA, Jurek P, Kiefer GE, Hyder F. Methylated tetra-amide derivatives of paramagnetic complexes for magnetic resonance biosensing with both BIRDS and CEST. NMR IN BIOMEDICINE 2022; 35:e4687. [PMID: 34970801 DOI: 10.1002/nbm.4687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 12/22/2021] [Accepted: 12/25/2021] [Indexed: 06/14/2023]
Abstract
Paramagnetic agents that utilize two mechanisms to provide physiological information by magnetic resonance imaging (MRI) and magnetic resonance spectroscopic imaging (MRSI) are described. MRI with chemical exchange saturation transfer (CEST) takes advantage of the agent's exchangeable protons (e.g., -OH or -NHx , where 2 ≥ x ≥ 1) to create pH contrast. The agent's incorporation of non-exchangeable protons (e.g., -CHy , where 3 ≥ y ≥ 1) makes it possible to map tissue temperature and/or pH using an MRSI method called biosensor imaging of redundant deviation in shifts (BIRDS). Hybrid probes based upon 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate chelate (DOTA4- ) and its methylated analog (1,4,7,10-tetraazacyclododecane-α, α', α″, α‴-tetramethyl-1,4,7,10-tetraacetate, DOTMA4- ) were synthesized, and modified to create new tetra-amide chelates. Addition of several methyl groups per pendent arm of the symmetrical chelates, positioned proximally and distally to thulium ions (Tm3+ ), gave rise to favorable BIRDS properties (i.e., high signal-to-noise ratio (SNR) from non-exchangeable methyl proton peaks) and CEST responsiveness (i.e., from amide exchangeable protons). Structures of the Tm3+ probes elucidate the influence of methyl group placement on sensor performance. An eight-coordinate geometry with high symmetry was observed for the complexes: Tm-L1 was based on DOTA4- , whereas Tm-L2 and Tm-L3 were based on DOTMA4- , where the latter contained an additional carboxylate at the distal end of each arm. The distance of Tm3+ from terminal methyl carbons is a key determinant for sustaining BIRDS temperature sensitivity without compromising CEST pH contrast; however, water solubility was influenced by introduction of hydrophobic methyl groups and hydrophilic carboxylate. Combined BIRDS and CEST detection of Tm-L2, which features two high-SNR methyl peaks and a strong amide CEST peak, should enable simultaneous temperature and pH measurements for high-resolution molecular imaging in vivo.
Collapse
Affiliation(s)
- Abul B M Zakaria
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
- Magnetic Resonance Research Center, Yale University, New Haven, Connecticut, USA
| | - Yuegao Huang
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
- Magnetic Resonance Research Center, Yale University, New Haven, Connecticut, USA
| | - Daniel Coman
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
- Magnetic Resonance Research Center, Yale University, New Haven, Connecticut, USA
| | - Sandeep K Mishra
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
- Magnetic Resonance Research Center, Yale University, New Haven, Connecticut, USA
| | - Jelena M Mihailovic
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
- Magnetic Resonance Research Center, Yale University, New Haven, Connecticut, USA
| | - Samuel Maritim
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
- Magnetic Resonance Research Center, Yale University, New Haven, Connecticut, USA
| | | | | | | | - Fahmeed Hyder
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
- Magnetic Resonance Research Center, Yale University, New Haven, Connecticut, USA
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA
| |
Collapse
|
4
|
Wellm V, Groebner J, Heitmann G, Sönnichsen FD, Herges R. Towards Photoswitchable Contrast Agents for Absolute 3D Temperature MR Imaging. Angew Chem Int Ed Engl 2021. [DOI: 10.1002/ange.202015851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Vanessa Wellm
- Otto Diels Institute of Organic Chemistry Christian Albrechts University Otto Hahn Platz 4 24118 Kiel Germany
| | - Jens Groebner
- Department of Electrical Engineering and Information Technology South Westphalian University of Applied Sciences Bahnhofsallee 5 58507 Luedenscheid Germany
| | - Gernot Heitmann
- IWS Innovations- und Wissenstrategien GmbH Aviares Research Network Deichstraße 25 20459 Hamburg Germany
| | - Frank D. Sönnichsen
- Otto Diels Institute of Organic Chemistry Christian Albrechts University Otto Hahn Platz 4 24118 Kiel Germany
| | - Rainer Herges
- Otto Diels Institute of Organic Chemistry Christian Albrechts University Otto Hahn Platz 4 24118 Kiel Germany
| |
Collapse
|
5
|
Wellm V, Groebner J, Heitmann G, Sönnichsen FD, Herges R. Towards Photoswitchable Contrast Agents for Absolute 3D Temperature MR Imaging. Angew Chem Int Ed Engl 2021; 60:8220-8226. [PMID: 33606332 PMCID: PMC8048480 DOI: 10.1002/anie.202015851] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Indexed: 12/27/2022]
Abstract
Temperature can be used as clinical marker for tissue metabolism and the detection of inflammations or tumors. The use of magnetic resonance imaging (MRI) for monitoring physiological parameters like the temperature noninvasively is steadily increasing. In this study, we present a proof-of-principle study of MRI contrast agents (CA) for absolute and concentration independent temperature imaging. These CAs are based on azoimidazole substituted NiII porphyrins, which can undergo Light-Driven Coordination-Induced Spin State Switching (LD-CISSS) in solution. Monitoring the fast first order kinetic of back isomerisation (cis to trans) with standard clinical MR imaging sequences allows the determination of half-lives, that can be directly translated into absolute temperatures. Different temperature responsive CAs were successfully tested as prototypes in methanol-based gels and created temperature maps of gradient phantoms with high spatial resolution (0.13×0.13×1.1 mm) and low temperature errors (<0.22 °C). The method is sufficiently fast to record the temperature flow from a heat source as a film.
Collapse
Affiliation(s)
- Vanessa Wellm
- Otto Diels Institute of Organic ChemistryChristian Albrechts UniversityOtto Hahn Platz 424118KielGermany
| | - Jens Groebner
- Department of Electrical Engineering and Information TechnologySouth Westphalian University of Applied SciencesBahnhofsallee 558507LuedenscheidGermany
| | - Gernot Heitmann
- IWS Innovations- und Wissenstrategien GmbHAviares Research NetworkDeichstraße 2520459HamburgGermany
| | - Frank D. Sönnichsen
- Otto Diels Institute of Organic ChemistryChristian Albrechts UniversityOtto Hahn Platz 424118KielGermany
| | - Rainer Herges
- Otto Diels Institute of Organic ChemistryChristian Albrechts UniversityOtto Hahn Platz 424118KielGermany
| |
Collapse
|
6
|
Du K, Zemerov SD, Hurtado Parra S, Kikkawa JM, Dmochowski IJ. Paramagnetic Organocobalt Capsule Revealing Xenon Host-Guest Chemistry. Inorg Chem 2020; 59:13831-13844. [PMID: 32207611 PMCID: PMC7672707 DOI: 10.1021/acs.inorgchem.9b03634] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
We investigated Xe binding in a previously reported paramagnetic metal-organic tetrahedral capsule, [Co4L6]4-, where L2- = 4,4'-bis[(2-pyridinylmethylene)amino][1,1'-biphenyl]-2,2'-disulfonate. The Xe-inclusion complex, [XeCo4L6]4-, was confirmed by 1H NMR spectroscopy to be the dominant species in aqueous solution saturated with Xe gas. The measured Xe dissociation rate in [XeCo4L6]4-, koff = 4.45(5) × 102 s-1, was at least 40 times greater than that in the analogous [XeFe4L6]4- complex, highlighting the capability of metal-ligand interactions to tune the capsule size and guest permeability. The rapid exchange of 129Xe nuclei in [XeCo4L6]4- produced significant hyperpolarized 129Xe chemical exchange saturation transfer (hyper-CEST) NMR signal at 298 K, detected at a concentration of [XeCo4L6]4- as low as 100 pM, with presaturation at -89 ppm, which was referenced to solvated 129Xe in H2O. The saturation offset was highly temperature-dependent with a slope of -0.41(3) ppm/K, which is attributed to hyperfine interactions between the encapsulated 129Xe nucleus and electron spins on the four CoII centers. As such, [XeCo4L6]4- represents the first example of a paramagnetic hyper-CEST (paraHYPERCEST) sensor. Remarkably, the hyper-CEST 129Xe NMR resonance for [XeCo4L6]4- (δ = -89 ppm) was shifted 105 ppm upfield from the diamagnetic analogue [XeFe4L6]4- (δ = +16 ppm). The Xe inclusion complex was further characterized in the crystal structure of (C(NH2)3)4[Xe0.7Co4L6]·75 H2O (1). Hydrogen bonding between capsule-linker sulfonate groups and exogenous guanidinium cations, (C(NH2)3)+, stabilized capsule-capsule interactions in the solid state and also assisted in trapping a Xe atom (∼42 Å3) in the large (135 Å3) cavity of 1. Magnetic susceptibility measurements confirmed the presence of four noninteracting, magnetically anisotropic high-spin CoII centers in 1. Furthermore, [Co4L6]4- was found to be stable toward aggregation and oxidation, and the CEST performance of [XeCo4L6]4- was unaffected by biological macromolecules in H2O. These results recommend metal-organic capsules for fundamental investigations of Xe host-guest chemistry as well as applications with highly sensitive 129Xe-based sensors.
Collapse
|
7
|
Raiko J, Koskensalo K, Sainio T. Imaging-based internal body temperature measurements: The journal Temperature toolbox. Temperature (Austin) 2020; 7:363-388. [PMID: 33251282 PMCID: PMC7678923 DOI: 10.1080/23328940.2020.1769006] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Revised: 05/08/2020] [Accepted: 05/11/2020] [Indexed: 12/27/2022] Open
Abstract
Noninvasive imaging methods of internal body temperature are in high demand in both clinical medicine and physiological research. Thermography and thermometry can be used to assess tissue temperature during thermal therapies: ablative and hyperthermia treatments to ensure adequate temperature rise in target tissues but also to avoid collateral damage by heating healthy tissues. In research use, measurement of internal body temperature enables us the production of thermal maps on muscles, internal organs, and other tissues of interest. The most used methods for noninvasive imaging of internal body temperature are based on different parameters acquired with magnetic resonance imaging, ultrasound, computed tomography, microwave radiometry, photoacoustic imaging, and near-infrared spectroscopy. In the current review, we examine the aforementioned imaging methods, their use in estimating internal body temperature in vivo with their advantages and disadvantages, and the physical phenomena the thermography or thermometry modalities are based on.
Collapse
Affiliation(s)
- Juho Raiko
- Turku PET Centre, University of Turku, Turku, Finland
- Department of Nutrition and Movement Sciences, Maastricht University, Maastricht, The Netherlands
| | - Kalle Koskensalo
- Department of Medical Physics, Turku University Hospital, Turku, Finland
| | - Teija Sainio
- Department of Medical Physics, Turku University Hospital, Turku, Finland
| |
Collapse
|
8
|
|
9
|
Odéen H, Parker DL. Magnetic resonance thermometry and its biological applications - Physical principles and practical considerations. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2019; 110:34-61. [PMID: 30803693 PMCID: PMC6662927 DOI: 10.1016/j.pnmrs.2019.01.003] [Citation(s) in RCA: 70] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Accepted: 01/23/2019] [Indexed: 05/25/2023]
Abstract
Most parameters that influence the magnetic resonance imaging (MRI) signal experience a temperature dependence. The fact that MRI can be used for non-invasive measurements of temperature and temperature change deep inside the human body has been known for over 30 years. Today, MR temperature imaging is widely used to monitor and evaluate thermal therapies such as radio frequency, microwave, laser, and focused ultrasound therapy. In this paper we cover the physical principles underlying the biological applications of MR temperature imaging and discuss practical considerations and remaining challenges. For biological tissue, the MR signal of interest comes mostly from hydrogen protons of water molecules but also from protons in, e.g., adipose tissue and various metabolites. Most of the discussed methods, such as those using the proton resonance frequency (PRF) shift, T1, T2, and diffusion only measure temperature change, but measurements of absolute temperatures are also possible using spectroscopic imaging methods (taking advantage of various metabolite signals as internal references) or various types of contrast agents. Currently, the PRF method is the most used clinically due to good sensitivity, excellent linearity with temperature, and because it is largely independent of tissue type. Because the PRF method does not work in adipose tissues, T1- and T2-based methods have recently gained interest for monitoring temperature change in areas with high fat content such as the breast and abdomen. Absolute temperature measurement methods using spectroscopic imaging and contrast agents often offer too low spatial and temporal resolution for accurate monitoring of ablative thermal procedures, but have shown great promise in monitoring the slower and usually less spatially localized temperature change observed during hyperthermia procedures. Much of the current research effort for ablative procedures is aimed at providing faster measurements, larger field-of-view coverage, simultaneous monitoring in aqueous and adipose tissues, and more motion-insensitive acquisitions for better precision measurements in organs such as the heart, liver, and kidneys. For hyperthermia applications, larger coverage, motion insensitivity, and simultaneous aqueous and adipose monitoring are also important, but great effort is also aimed at solving the problem of long-term field drift which gets interpreted as temperature change when using the PRF method.
Collapse
Affiliation(s)
- Henrik Odéen
- University of Utah, Utah Center for Advanced Imaging Research, Department of Radiology and Imaging Sciences, 729 Arapeen Drive, Salt Lake City, UT 84108-1217, USA.
| | - Dennis L Parker
- University of Utah, Utah Center for Advanced Imaging Research, Department of Radiology and Imaging Sciences, 729 Arapeen Drive, Salt Lake City, UT 84108-1217, USA.
| |
Collapse
|
10
|
Abstract
Thermal ablation techniques such as radiofrequency, microwave, high intensity focused ultrasound (HIFU) and laser have been used as minimally invasive strategies for the treatment of variety of cancers. MR thermometry methods are readily available for monitoring thermal distribution and deposition in real time, leading to decrease of incidents of normal tissue damage around targeted lesion. HIFU and laser-induced thermal therapy (LITT) are the two widely accepted tumor ablation techniques because of their compatibility with MR systems. MRI provides multiple temperature dependent parameters for thermal imaging, such as signal intensity, T1, T2, diffusion coefficient, magnetization transfer, proton resonance frequency shift (PRFS, including phase imaging and spectroscopy) as well as frequency shift of temperature sensitive contrast agents. Absolute temperature mapping techniques, including both spectroscopic imaging using metabolites as a reference and phase imaging using fat as a reference, are immune to susceptibility effects and are not dependent on phase differences. These techniques are intrinsically more reliable than relative temperature measurement by phase mapping methods. If the limitation of low temporal and spatial resolution could be overcome, these methods may be preferred for MR-guided thermal ablation systems. As of today, the most popular MR thermal imaging method applied in tumor thermal ablation surgery is, however, still PRFS based phase mapping technique, which only provides relative temperature change and is prone to motion artifacts.
Collapse
Affiliation(s)
- Mingming Zhu
- Department of Radiology, School of Medicine, University of Louisville, Louisville, KY, USA
| | - Ziqi Sun
- Department of Radiology, School of Medicine, University of Louisville, Louisville, KY, USA
| | - Chin K Ng
- Department of Radiology, School of Medicine, University of Louisville, Louisville, KY, USA
| |
Collapse
|
11
|
Thorarinsdottir AE, Gaudette AI, Harris TD. Spin-crossover and high-spin iron(ii) complexes as chemical shift 19F magnetic resonance thermometers. Chem Sci 2017; 8:2448-2456. [PMID: 28694955 PMCID: PMC5477811 DOI: 10.1039/c6sc04287b] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2016] [Accepted: 12/20/2016] [Indexed: 12/22/2022] Open
Abstract
The potential utility of paramagnetic transition metal complexes as chemical shift 19F magnetic resonance (MR) thermometers is demonstrated. Further, spin-crossover FeII complexes are shown to provide much higher temperature sensitivity than do the high-spin analogues, owing to the variation of spin state with temperature in the former complexes. This approach is illustrated through a series of FeII complexes supported by symmetrically and asymmetrically substituted 1,4,7-triazacyclononane ligand scaffolds bearing 3-fluoro-2-picolyl derivatives as pendent groups (L x ). Variable-temperature magnetic susceptibility measurements, in conjunction with UV-vis and NMR data, show thermally-induced spin-crossover for [Fe(L1)]2+ in H2O, with T1/2 = 52(1) °C. Conversely, [Fe(L2)]2+ remains high-spin in the temperature range 4-61 °C. Variable-temperature 19F NMR spectra reveal the chemical shifts of the complexes to exhibit a linear temperature dependence, with the two peaks of the spin-crossover complex providing temperature sensitivities of +0.52(1) and +0.45(1) ppm per °C in H2O. These values represent more than two-fold higher sensitivity than that afforded by the high-spin analogue, and ca. 40-fold higher sensitivity than diamagnetic perfluorocarbon-based thermometers. Finally, these complexes exhibit excellent stability in a physiological environment, as evidenced by 19F NMR spectra collected in fetal bovine serum.
Collapse
Affiliation(s)
- Agnes E Thorarinsdottir
- Department of Chemistry , Northwestern University , 2145 Sheridan Road , Evanston , IL 60208-3113 , USA .
| | - Alexandra I Gaudette
- Department of Chemistry , Northwestern University , 2145 Sheridan Road , Evanston , IL 60208-3113 , USA .
| | - T David Harris
- Department of Chemistry , Northwestern University , 2145 Sheridan Road , Evanston , IL 60208-3113 , USA .
| |
Collapse
|
12
|
Alon L, Sodickson DK, Deniz CM. Heat equation inversion framework for average SAR calculation from magnetic resonance thermal imaging. Bioelectromagnetics 2016; 37:493-503. [PMID: 27490064 PMCID: PMC5538363 DOI: 10.1002/bem.21996] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2015] [Accepted: 07/16/2016] [Indexed: 12/27/2022]
Abstract
Deposition of radiofrequency (RF) energy can be quantified via electric field or temperature change measurements. Magnetic resonance imaging has been used as a tool to measure three dimensional small temperature changes associated with RF radiation exposure. When duration of RF exposure is long, conversion from temperature change to specific absorption rate (SAR) is nontrivial due to prominent heat-diffusion and conduction effects. In this work, we demonstrated a method for calculation of SAR via an inversion of the heat equation including heat-diffusion and conduction effects. This method utilizes high-resolution three dimensional magnetic resonance temperature images and measured thermal properties of the phantom to achieve accurate calculation of SAR. Accuracy of the proposed method was analyzed with respect to operating frequency of a dipole antenna and parameters used in heat equation inversion. Bioelectromagnetics. 37:493-503, 2016. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Leeor Alon
- Department of Radiology, Center for Advanced Imaging Innovation and Research (CAI2R), New York University School of Medicine, New York City, New York.
- The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York City, New York.
- NYU WIRELESS, Polytechnic Institute of New York University, Brooklyn, New York.
- RF Test Labs, New York City, New York.
| | - Daniel K Sodickson
- Department of Radiology, Center for Advanced Imaging Innovation and Research (CAI2R), New York University School of Medicine, New York City, New York
- The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York City, New York
- NYU WIRELESS, Polytechnic Institute of New York University, Brooklyn, New York
| | - Cem M Deniz
- Department of Radiology, Center for Advanced Imaging Innovation and Research (CAI2R), New York University School of Medicine, New York City, New York
- The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York City, New York
- NYU WIRELESS, Polytechnic Institute of New York University, Brooklyn, New York
- RF Test Labs, New York City, New York
| |
Collapse
|
13
|
Umegawa Y, Tanaka Y, Nobuaki M, Murata M. (13) C-TmDOTA as versatile thermometer compound for solid-state NMR of hydrated lipid bilayer membranes. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2016; 54:227-233. [PMID: 26460094 DOI: 10.1002/mrc.4371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2015] [Revised: 09/03/2015] [Accepted: 09/19/2015] [Indexed: 06/05/2023]
Abstract
Recent advances in solid-state nuclear magnetic resonance (NMR) techniques, such as magic angle spinning and high-power decoupling, have dramatically increased the sensitivity and resolution of NMR. However, these NMR techniques generate extra heat, causing a temperature difference between the sample in the rotor and the variable temperature gas. This extra heating is a particularly crucial problem for hydrated lipid membrane samples. Thus, to develop an NMR thermometer that is suitable for hydrated lipid samples, thulium-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate (TmDOTA) was synthesized and labeled with (13) C (i.e., (13) C-TmDOTA) to increase the NMR sensitivity. The complex was mixed with a hydrated lipid membrane, and the system was subjected to solid-state NMR and differential scanning calorimetric analyses. The physical properties of the lipid bilayer and the quality of the NMR spectra of the membrane were negligibly affected by the presence of (13) C-TmDOTA, and the (13) C chemical shift of the complex exhibited a large-temperature dependence. The results demonstrated that (13) C-TmDOTA could be successfully used as a thermometer to accurately monitor temperature changes induced by (1) H decoupling pulses and/or by magic angle spinning and the temperature distribution of the sample inside the rotor. Thus, (13) C-TmDOTA was shown to be a versatile thermometer for hydrated lipid assemblies. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Yuichi Umegawa
- JST ERATO, Lipid Active Structure Project, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka, 560-0043, Japan
- Department of Chemistry, Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka, 560-0043, Japan
| | - Yuya Tanaka
- Department of Chemistry, Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka, 560-0043, Japan
| | - Matsumori Nobuaki
- Department of Chemistry, Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka, 560-0043, Japan
| | - Michio Murata
- JST ERATO, Lipid Active Structure Project, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka, 560-0043, Japan
- Department of Chemistry, Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka, 560-0043, Japan
| |
Collapse
|
14
|
Huang Y, Coman D, Hyder F, Ali MM. Dendrimer-Based Responsive MRI Contrast Agents (G1-G4) for Biosensor Imaging of Redundant Deviation in Shifts (BIRDS). Bioconjug Chem 2015; 26:2315-23. [PMID: 26497087 DOI: 10.1021/acs.bioconjchem.5b00568] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Biosensor imaging of redundant deviation in shifts (BIRDS) is a molecular imaging platform for magnetic resonance that utilizes unique properties of low molecular weight paramagnetic monomers by detecting hyperfine-shifted nonexchangeable protons and transforming the chemical shift information to reflect its microenvironment (e.g., via temperature, pH, etc.). To optimize translational biosensing potential of BIRDS we examined if this detection scheme observed with monomers can be extended onto dendrimers, which are versatile and biocompatible macromolecules with modifiable surface for molecular imaging and drug delivery. Here we report on feasibility of paramagnetic dendrimers for BIRDS. The results show that BIRDS is resilient with paramagnetic dendrimers up to the fourth generation (i.e., G1-G4), where the model dendrimer and chelate were based on poly(amido amine) (PAMAM) and 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA(4-)) complexed with thulium ion (Tm(3+)). Temperature sensitivities of two prominent signals of Gn-PAMAM-(TmDOTA(-))x (where n = 1-4, x = 6-39) were comparable to that of prominent signals in TmDOTA(-). Transverse relaxation times of the coalesced nonexchangeable protons on Gn-PAMAM-(TmDOTA(-))x were relatively short to provide signal-to-noise ratio that was comparable to or better than that of TmDOTA(-). A fluorescent dye, rhodamine, was conjugated to a G2-PAMAM-(TmDOTA)12 to create a dual-modality nanosized contrast agent. BIRDS properties of the dendrimer were unaltered with rhodamine conjugation. Purposely designed paramagnetic dendrimers for BIRDS in conjunction with novel macromolecular surface modification for functional ligands/drugs could potentially be used for biologically compatible theranostic sensors.
Collapse
Affiliation(s)
| | | | | | - Meser M Ali
- Department of Neurology, Henry Ford Hospital , Detroit, Michigan 48202, United States
| |
Collapse
|
15
|
Dharmadhikari S, James JR, Nyenhuis J, Bansal N. Evaluation of radiofrequency safety by high temperature resolution MR thermometry using a paramagnetic lanthanide complex. Magn Reson Med 2015; 75:2121-9. [DOI: 10.1002/mrm.25792] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2015] [Revised: 05/05/2015] [Accepted: 05/06/2015] [Indexed: 11/09/2022]
Affiliation(s)
- Shalmali Dharmadhikari
- School of Health Sciences, Purdue University; West Lafayette Indiana USA
- Department of Radiology and Imaging Sciences; Indiana University School of Medicine; Indianapolis Indiana USA
| | - Judy R. James
- Department of Radiology; Mayo Clinic, Scottsdale; Arizona USA
| | - John Nyenhuis
- Department of Electrical and Computer Engineering; Purdue University; West Lafayette Indiana USA
| | - Navin Bansal
- Department of Radiology and Imaging Sciences; Indiana University School of Medicine; Indianapolis Indiana USA
| |
Collapse
|
16
|
Galezowska J, Gumienna-Kontecka E. Phosphonates, their complexes and bio-applications: A spectrum of surprising diversity. Coord Chem Rev 2012. [DOI: 10.1016/j.ccr.2011.07.002] [Citation(s) in RCA: 98] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
17
|
Milne M, Hudson RH. Contrast agents possessing high temperature sensitivity. Chem Commun (Camb) 2011; 47:9194-6. [DOI: 10.1039/c1cc13073k] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
18
|
Coman D, Trubel HK, Hyder F. Brain temperature by Biosensor Imaging of Redundant Deviation in Shifts (BIRDS): comparison between TmDOTP5- and TmDOTMA-. NMR IN BIOMEDICINE 2010; 23:277-85. [PMID: 19957287 PMCID: PMC2843767 DOI: 10.1002/nbm.1461] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Chemical shifts of complexes between paramagnetic lanthanide ions and macrocyclic chelates are sensitive to physiological variations (of temperature and/or pH). Here we demonstrate utility of a complex between thulium ion (Tm(3+)) and the macrocyclic chelate 1,4,7,10-tetramethyl 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate (or DOTMA(4-)) for absolute temperature mapping in rat brain. The feasibility of TmDOTMA(-) is compared with that of another Tm(3+)-containing biosensor which is based on the macrocyclic chelate 1,4,7,10-tetraazacyclododecane- 1,4,7,10-tetrakis(methylene phosphonate) (or DOTP(8-)). In general, the in vitro and in vivo results suggest that Biosensor Imaging of Redundant Deviation in Shifts (BIRDS) which originate from these agents (but exclude water) can provide temperature maps with good accuracy. While TmDOTP(5-) emanates three major distinct proton resonances which are differentially sensitive to temperature and pH, TmDOTMA(-) has a dominant pH-insensitive proton resonance from a -CH(3) group to allow higher signal-to-noise ratio (SNR) temperature assessment. Temperature (and pH) sensitivities of these resonances are practically identical at low (4.0T) and high (11.7T) magnetic fields and at nominal repetition times only marginal SNR loss is expected at the lower field. Since these resonances have extremely short relaxation times, high-speed chemical shift imaging (CSI) is needed to detect them. Repeated in vivo CSI scans with BIRDS demonstrate excellent measurement stability. Overall, results with TmDOTP(5-) and TmDOTMA(-) suggest that BIRDS can be reliably applied, either at low or high magnetic fields, for functional studies in rodents.
Collapse
Affiliation(s)
- Daniel Coman
- Magnetic Resonance Research Center (MRRC), Yale University, New Haven, CT 06520, USA
- Core Center for Quantitative Neuroscience with Magnetic Resonance (QNMR), Yale University, New Haven, CT 06520, USA
- Department of Diagnostic Radiology, Yale University, New Haven, CT 06520, USA
| | - Hubert K. Trubel
- Magnetic Resonance Research Center (MRRC), Yale University, New Haven, CT 06520, USA
- Department of Diagnostic Radiology, Yale University, New Haven, CT 06520, USA
- Department of Pediatrics at HELIOS-Klinikum Wuppertal and University of Witten/Herdecke, Germany
| | - Fahmeed Hyder
- Magnetic Resonance Research Center (MRRC), Yale University, New Haven, CT 06520, USA
- Core Center for Quantitative Neuroscience with Magnetic Resonance (QNMR), Yale University, New Haven, CT 06520, USA
- Department of Diagnostic Radiology, Yale University, New Haven, CT 06520, USA
- Department of Biomedical Engineering, Yale University, New Haven, CT 06520, USA
| |
Collapse
|
19
|
Lüdemann L, Wlodarczyk W, Nadobny J, Weihrauch M, Gellermann J, Wust P. Non-invasive magnetic resonance thermography during regional hyperthermia. Int J Hyperthermia 2010; 26:273-82. [DOI: 10.3109/02656731003596242] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
20
|
James JR, Gao Y, Soon VC, Topper SM, Babsky A, Bansal N. Controlled radio-frequency hyperthermia using an MR scanner and simultaneous monitoring of temperature and therapy response by (1)H, (23)Na and (31)P magnetic resonance spectroscopy in subcutaneously implanted 9L-gliosarcoma. Int J Hyperthermia 2010; 26:79-90. [PMID: 20100055 DOI: 10.3109/02656730903373509] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
A magnetic resonance (MR) technique is developed to produce controlled radio-frequency (RF) hyperthermia (HT) in subcutaneously-implanted 9L-gliosarcoma in Fisher rats using an MR scanner and its components; the scanner is also simultaneously used to monitor the tumour temperature and the metabolic response of the tumour to the therapy. The method uses the (1)H chemical shift of thulium 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetra-acetic acid (TmDOTA(-)) to monitor temperature. The desired HT temperature is achieved and maintained using a feedback loop mechanism that uses a proportional-integral-derivative controller. The RF HT technique was able to heat the tumour from 33 degrees to 45 degrees C in approximately 10 min and was able to maintain the tumour temperature within +/-0.2 degrees C of the target temperature (45 degrees C). Simultaneous monitoring of the metabolic changes with RF HT showed increases in total tissue and intracellular Na(+) as measured by single-quantum and triple-quantum filtered (23)Na MR spectroscopy (MRS), respectively, and decreases in intra- and extracellular pH and cellular bioenergetics as measured by (31)P MRS. Monitoring of metabolic response in addition to the tumour temperature measurements may serve as a more reliable and early indicator of therapy response. In addition, such measurements during HT treatment will enhance our understanding of the tumour response mechanisms during HT, which may prove valuable in designing methods to improve therapeutic efficiency.
Collapse
Affiliation(s)
- Judy R James
- Department of Radiology, Indiana University School of Medicine, Indianapolis, Indiana 46202-5181, USA
| | | | | | | | | | | |
Collapse
|
21
|
James JR, Gao Y, Miller MA, Babsky A, Bansal N. Absolute temperature MR imaging with thulium 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetramethyl-1,4,7,10-tetraacetic acid (TmDOTMA-). Magn Reson Med 2009; 62:550-6. [PMID: 19526494 DOI: 10.1002/mrm.22039] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
MR thermometry based on the water (1)H signal provides high temporal and spatial resolution, but it has low temperature sensitivity (approximately 0.01 ppm/degrees C) and requires monitoring of another weaker signal for absolute temperature measurements. The use of the paramagnetic lanthanide complex, thulium 1,4,7,10- tetraazacyclododecane-1,4,7,10-tetramethyl-1,4,7,10-tetraacetate (TmDOTMA(-)), which is approximately 60 times more sensitive to temperature than the water (1)H signal, is advanced to image absolute temperatures in vivo using water signal as a reference. The temperature imaging technique was developed using gradient echo and asymmetric spin echo imaging sequences on 9.4 Tesla (T) horizontal and vertical MR scanners. A comparison of regional temperatures measured with TmDOTMA(-) and fiber-optic probes showed that the accuracy of imaging temperature is <0.3 degrees C. The temperature imaging technique was found to be insensitive to inhomogeneities in the main magnetic field. The feasibility of imaging temperature of intact rats at approximately 1.4 mmol/kg dose with approximately 1-mm spatial resolution in only 3 min is demonstrated. TmDOTMA(-) should prove useful for imaging absolute temperatures in deep-seated organs in numerous biomedical applications.
Collapse
Affiliation(s)
- Judy R James
- Department of Radiology, Indiana University School of Medicine, Indianapolis, IN 46202-5181, USA
| | | | | | | | | |
Collapse
|
22
|
Geraldes CFGC, Laurent S. Classification and basic properties of contrast agents for magnetic resonance imaging. CONTRAST MEDIA & MOLECULAR IMAGING 2009; 4:1-23. [PMID: 19156706 DOI: 10.1002/cmmi.265] [Citation(s) in RCA: 357] [Impact Index Per Article: 23.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
A comprehensive classification of contrast agents currently used or under development for magnetic resonance imaging (MRI) is presented. Agents based on small chelates, macromolecular systems, iron oxides and other nanosystems, as well as responsive, chemical exchange saturation transfer (CEST) and hyperpolarization agents are covered in order to discuss the various possibilities of using MRI as a molecular imaging technique. The classification includes composition, magnetic properties, biodistribution and imaging applications. Chemical compositions of various classes of MRI contrast agents are tabulated, and their magnetic status including diamagnetic, paramagnetic and superparamagnetic are outlined. Classification according to biodistribution covers all types of MRI contrast agents including, among others, extracellular, blood pool, polymeric, particulate, responsive, oral, and organ specific (hepatobiliary, RES, lymph nodes, bone marrow and brain). Various targeting strategies of molecular, macromolecular and particulate carriers are also illustrated.
Collapse
Affiliation(s)
- Carlos F G C Geraldes
- Department of Biochemistry, Faculty of Science and Technology, and Center of Neurosciences and Cell Biology, University of Coimbra, P-3001-401 Coimbra, Portugal.
| | | |
Collapse
|
23
|
Zhu M, Bashir A, Ackerman JJ, Yablonskiy DA. Improved calibration technique for in vivo proton MRS thermometry for brain temperature measurement. Magn Reson Med 2009; 60:536-41. [PMID: 18727039 DOI: 10.1002/mrm.21699] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The most common MR-based approach to noninvasively measure brain temperature relies on the linear relationship between the (1)H MR resonance frequency of tissue water and the tissue's temperature. Herein we provide the most accurate in vivo assessment existing thus far of such a relationship. It was derived by acquiring in vivo MR spectra from a rat brain using a high field (11.74 Tesla [T]) MRI scanner and a single-voxel MR spectroscopy technique based on a LASER pulse sequence. Data were analyzed using three different methods to estimate the (1)H resonance frequencies of water and the metabolites NAA, Cho, and Cr, which are used as temperature-independent internal (frequency) references. Standard modeling of frequency-domain data as composed of resonances characterized by Lorentzian line shapes gave the tightest resonance-frequency versus temperature correlation. An analysis of the uncertainty in temperature estimation has shown that the major limiting factor is an error in estimating the metabolite frequency. For example, for a metabolite resonance linewidth of 8 Hz, signal sampling rate of 2 Hz and SNR of 5, an accuracy of approximately 0.5 degrees C can be achieved at a magnetic field of 3T. For comparison, in the current study conducted at 11.74T, the temperature estimation error was approximately 0.1 degrees C.
Collapse
Affiliation(s)
- M Zhu
- Department of Chemistry, Washington University, Saint Louis, Missouri 63110, USA
| | | | | | | |
Collapse
|
24
|
Coman D, Trubel HK, Rycyna RE, Hyder F. Brain temperature and pH measured by (1)H chemical shift imaging of a thulium agent. NMR IN BIOMEDICINE 2009; 22:229-39. [PMID: 19130468 PMCID: PMC2735415 DOI: 10.1002/nbm.1312] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Temperature and pH are two of the most important physiological parameters and are believed to be tightly regulated because they are intricately related to energy metabolism in living organisms. Temperature and/or pH data in mammalian brain are scarce, however, mainly because of lack of precise and non-invasive methods. At 11.7 T, we demonstrate that a thulium-based macrocyclic complex infused through the bloodstream can be used to obtain temperature and pH maps of rat brain in vivo by (1)H chemical shift imaging (CSI) of the sensor itself in conjunction with a multi-parametric model that depends on several proton resonances of the sensor. Accuracies of temperature and pH determination with the thulium sensor - which has a predominantly extracellular presence - depend on stable signals during the course of the CSI experiment as well as redundancy for temperature and pH sensitivities contained within the observed signals. The thulium-based method compared well with other methods for temperature ((1)H MRS of N-acetylaspartate and water; copper-constantan thermocouple wire) and pH ((31)P MRS of inorganic phosphate and phosphocreatine) assessment, as established by in vitro and in vivo studies. In vitro studies in phantoms with two compartments of different pH value observed under different ambient temperature conditions generated precise temperature and pH distribution maps. In vivo studies in alpha-chloralose-anesthetized and renal-ligated rats revealed temperature (33-34 degrees C) and pH (7.3-7.4) distributions in the cerebral cortex that are in agreement with observations by other methods. These results show that the thulium sensor can be used to measure temperature and pH distributions in rat brain in vivo simultaneously and accurately using Biosensor Imaging of Redundant Deviation in Shifts (BIRDS).
Collapse
Affiliation(s)
- Daniel Coman
- Magnetic Resonance Research Center (MRRC), Yale University, New Haven, CT 06520, USA
- Quantitative Neuroscience with Magnetic Resonance (QNMR), Yale University, New Haven, CT 06520, USA
- Department of Diagnostic Radiology, Yale University, New Haven, CT 06520, USA
| | - Hubert K. Trubel
- Magnetic Resonance Research Center (MRRC), Yale University, New Haven, CT 06520, USA
- Department of Diagnostic Radiology, Yale University, New Haven, CT 06520, USA
- University of Witten/Herdecke, Germany
| | | | - Fahmeed Hyder
- Magnetic Resonance Research Center (MRRC), Yale University, New Haven, CT 06520, USA
- Quantitative Neuroscience with Magnetic Resonance (QNMR), Yale University, New Haven, CT 06520, USA
- Department of Diagnostic Radiology, Yale University, New Haven, CT 06520, USA
- Biomedical Engineering Yale University, New Haven, CT 06520, USA
| |
Collapse
|
25
|
Zhao JM, Har-el YE, McMahon MT, Zhou J, Sherry AD, Sgouros G, Bulte JWM, van Zijl PCM. Size-induced enhancement of chemical exchange saturation transfer (CEST) contrast in liposomes. J Am Chem Soc 2008; 130:5178-84. [PMID: 18361490 PMCID: PMC2759111 DOI: 10.1021/ja710159q] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Liposome-based chemical exchange saturation transfer (lipoCEST) agents have shown great sensitivity and potential for molecular magnetic resonance imaging (MRI). Here we demonstrate that the size of liposomes can be exploited to enhance the lipoCEST contrast. A concise analytical model is developed to describe the contrast dependence on size for an ensemble of liposomes. The model attributes the increased lipoCEST contrast in smaller liposomes to their larger surface-to-volume ratio, causing an increased membrane water exchange rate. Experimentally measured rates correlate with size, in agreement with the model. The water permeability of liposomal membrane is found to be 1.11 +/- 0.14 microm/s for the specific lipid composition at 22 degrees C. Availability of the model allows rational design of the size of liposomes and quantification of their properties. These new theoretical and experimental tools are expected to benefit applications of liposomes to sensing the cellular environment, targeting and imaging biological processes, and optimizing drug delivery properties.
Collapse
|
26
|
Adair C, Woods M, Zhao P, Pasha A, Winter PM, Lanza GM, Athey P, Sherry AD, Kiefer GE. Spectral properties of a bifunctional PARACEST europium chelate: an intermediate for targeted imaging applications. CONTRAST MEDIA & MOLECULAR IMAGING 2007; 2:55-8. [PMID: 17326038 DOI: 10.1002/cmmi.125] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This report describes a preliminary study to investigate the effect of structural variations in a bifunctional ligand being developed for targeted PARACEST applications. Utilizing Eu-DOTA-4AmCE as the functional PARACEST core, a nitro-aromatic functionality was incorporated to provide the point for conjugation. This intermediate possesses a coordinated water proton signal at 57 ppm which upon saturation produces a 22% decrease in bulk water signal intensity using 10 mM agent. Curve fitting analysis of the CEST spectrum to an exchange model based upon modified Bloch equations gave an estimate of 687 +/- 100 micros for the bound water lifetime (tau(m)). Although substantially longer than the 382 micros observed for the parent chelate structure, this water exchange rate remains in the necessary window to produce a significant CEST effect. These findings demonstrate the need to recognize the influence of bifunctional linkers on water exchange rates in lanthanide complexes of this type and the potential for using this functionality as a means of fine-tuning PARACEST performance.
Collapse
|
27
|
Pakin SK, Hekmatyar SK, Hopewell P, Babsky A, Bansal N. Non-invasive temperature imaging with thulium 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetramethyl-1,4,7,10-tetraacetic acid (TmDOTMA-). NMR IN BIOMEDICINE 2006; 19:116-24. [PMID: 16404728 DOI: 10.1002/nbm.1010] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Non-invasive thermometry using hyperfine-shifted MR signals from paramagnetic lanthanide complexes has attracted attention recently because the chemical shifts of these complexes are many times more sensitive to temperature than the water 1H signal. Among all the lanthanide complexes examined thus far, thulium tetramethyl-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate (TmDOTMA-) appears to be the most suitable for MR thermometry. In this paper, the feasibility of imaging the methyl 1H signal from TmDOTMA- using a frequency-selective radiofrequency excitation pulse and chemical shift-selective (CHESS) water suppression is demonstrated. A temperature imaging method using a phase-sensitive spin-echo imaging sequence was validated in phantom experiments. A comparison of regional temperature changes measured with fiber-optic probes and the temperatures calculated from the phase shift near each probe showed that the accuracy of imaging the temperature with TmDOTMA- is at least 0.1-0.2 degrees C. The feasibility of imaging temperature changes in an intact rat at 0.5-0.6 mmol/kg dose in only a few minutes is demonstrated. Similar to commonly used MRI contrast agents, the lanthanide complex does not cross the blood-brain barrier. TmDOTMA- may prove useful for temperature imaging in many biomedical applications but further studies relating to acceptable dose and signal-to-noise ratio are necessary before clinical applications.
Collapse
Affiliation(s)
- Sait Kubilay Pakin
- Department of Radiology, Indiana University School of Medicine, Indianapolis, IN 46202-5181, USA
| | | | | | | | | |
Collapse
|
28
|
Pisani LJ, Ross AB, Diederich CJ, Nau WH, Sommer FG, Glover GH, Butts K. Effects of spatial and temporal resolution for MR image-guided thermal ablation of prostate with transurethral ultrasound. J Magn Reson Imaging 2005; 22:109-18. [PMID: 15971190 DOI: 10.1002/jmri.20339] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To describe approaches for determining optimal spatial and temporal resolutions for the proton resonance frequency shift method of quantitative magnetic resonance temperature imaging (MRTI) guidance of transurethral ultrasonic prostate ablation. MATERIALS AND METHODS Temperature distributions of two transurethral ultrasound applicators (90 degrees sectored tubular and planar arrays) for canine prostate ablation were measured via MRTI during in vivo sonication, and agree well with two-dimensional finite difference model simulations at various spatial resolutions. Measured temperature distributions establish the relevant signal-to-noise ratio (SNR) range for thermometry in an interventional MR scanner, and are reconstructed at different resolutions to compare resultant temperature measurements. Various temporal resolutions are calculated by averaging MRTI frames. RESULTS When noise is added to simulated temperature distributions for tubular and planar applicators, the minimum root mean squared (RMS) error is achieved by reconstructing to pixel sizes of 1.9 and 1.7 mm, respectively. In in vivo measurements, low spatial resolution MRTI data are shown to reduce the noise without significantly affecting thermal dose calculations. Temporal resolution of 0.66 frames/minute leads to measurement errors of more than 12 degrees C during rapid heating. CONCLUSION Optimizing MRTI pixel size entails balancing large pixel SNR gain with accuracy in representing underlying temperature distributions.
Collapse
Affiliation(s)
- Laura J Pisani
- Stanford University, Lucas MRS Center, Stanford, California, USA.
| | | | | | | | | | | | | |
Collapse
|
29
|
Hekmatyar SK, Hopewell P, Pakin SK, Babsky A, Bansal N. Noninvasive MR thermometry using paramagnetic lanthanide complexes of 1,4,7,10-tetraazacyclodoecane-?,??,??,??-tetramethyl-1,4,7,10-tetraacetic acid (DOTMA4-). Magn Reson Med 2005; 53:294-303. [PMID: 15678553 DOI: 10.1002/mrm.20345] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Noninvasive techniques to monitor temperature have numerous useful biomedical applications. However, MR thermometry techniques based on the chemical shift, relaxation rates, and molecular diffusion rate of the water 1H signal suffer from poor thermal resolution. The feasibility of MR thermometry based on the strong temperature dependence of the hyperfine-shifted 1H signal from the paramagnetic lanthanide complex thulium-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate (TmDOTA-) was recently demonstrated. The use of paramagnetic lanthanide complexes for MR thermometry can be further enhanced by improving the signal-to-noise ratio (SNR) of the observed signal. In this study, the use of lanthanide complexes of a methyl-substituted analog of DOTA4-, 1,4,7,10-tetramethyl 1,4,7,10-tetra azacyclodoecane-1,4,7,10-tetraacetic acetate (DOTMA4-) was evaluated. DOTMA4- complexes have 12 magnetically equivalent methyl protons, which provide an intense and sharper resonance compared to the corresponding DOTA- complexes. Experiments with paramagnetic Pr3+, Yb3+, Tb3+, Dy3+, and Tm3+ complexes of DOTMA4- showed that the Tm3+ complex is most favorable for MR thermometery because of the high temperature dependence of its chemical shift and its relatively narrow linewidth. The chemical shift of the methyl 1H signal from TmDOTMA- was approximately 60 times more sensitive to temperature than the water 1H shift and was insensitive to changes in concentration, pH, [Ca2+], or the presence of other ions and macromolecules. The application of TmDOTMA- for measuring temperature in a subcutaneously implanted tumor model was demonstrated. Lastly, the feasibility of obtaining 3D images from the methyl 1H resonance of TmDOTMA- was demonstrated in phantom and live animal experiments. Overall, TmDOTMA- appears to be a promising probe for MR thermometry in vivo.
Collapse
Affiliation(s)
- S K Hekmatyar
- Department of Radiology, Indiana University School of Medicine, Indianapolis, Indiana 46202-5181, USA
| | | | | | | | | |
Collapse
|
30
|
Dreher MR, Elas M, Ichikawa K, Barth ED, Chilkoti A, Rosen GM, Halpern HJ, Dewhirst M. Nitroxide conjugate of a thermally responsive elastin-like polypeptide for noninvasive thermometry. Med Phys 2004; 31:2755-62. [PMID: 15543780 DOI: 10.1118/1.1782677] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Hyperthermia, as an adjuvant with radiation and chemotherapy, has shown promise in the treatment of cancer. The relevant biological effects of a hyperthermia treatment are both time and temperature-dependent, creating a need for accurate thermometry. We present a novel noninvasive thermometry modality that combines a temperature responsive biopolymer, the elastin-like polypeptide (ELP), and nitroxide to produce an ELP-nitroxide conjugate. When examined with electron paramagnetic resonance (EPR) spectroscopy, the ELP-nitroxide conjugate has temperature-dependent spectral line widths whose predictive accuracy is approximately 0.3 degrees C (80 microM). We believe that the temperature-dependent changes observed in the EPR spectrum are due to the combined effect of temperature, viscosity and effective radius on the rotational correlation time of the ELP-nitroxide conjugate.
Collapse
Affiliation(s)
- Matthew R Dreher
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, USA
| | | | | | | | | | | | | | | |
Collapse
|
31
|
McDannold N, Fossheim SL, Rasmussen H, Martin H, Vykhodtseva N, Hynynen K. Heat-activated Liposomal MR Contrast Agent: Initial in Vivo Results in Rabbit Liver and Kidney. Radiology 2004; 230:743-52. [PMID: 14764890 DOI: 10.1148/radiol.2303021713] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate by using in vivo magnetic resonance (MR) imaging the functionality of a liposomal paramagnetic contrast agent with T1 relaxivity that rapidly and markedly increases at temperatures above the gel-to-liquid crystalline phase transition temperature (T(c)) of the liposome membrane. MATERIALS AND METHODS Liposomal gadolinium diethylenetriaminepentaacetic acid bis(methylamide) was injected intravenously at a dose of 0.4 or 1.2 mL (containing 10 or 30 micromol of gadolinium, respectively) per kilogram of body weight shortly before the application of focused ultrasound in liver (seven rabbits) or kidney (three rabbits). VX2 tumors had been implanted in liver in four of the rabbits. Eighteen locations in liver (13 in normal tissue, five in tumor) and 12 locations in kidney were sonicated. MR thermometry was performed during sonications. Signal intensity enhancement was evaluated on T1-weighted images acquired after the tissue cooled, and enhanced zones were compared with isotherms at T(c) of the liposome membrane (approximately 57 degrees C) by using Bland-Altman analysis. In liver, enhanced zones also were compared with areas of histologically verified thermal damage. The threshold temperature of enhancement at T1-weighted imaging was verified by monitoring the signal intensity increase after 10 sonications at varied powers in two locations in normal liver tissue. RESULTS Persistent enhancement was observed on T1-weighted images at all sonicated liver locations. In liver, enhanced zones on T1-weighted images were contiguous both with 57 degrees C isotherms (25 measurements; mean difference +/- SD, 0.4 mm +/- 1.2) and with histologically verified areas of necrosis (seven measurements; mean difference +/- SD, 0.1 mm +/- 0.9). The threshold temperature of enhancement at T1-weighted imaging in normal liver was 53 degrees -57 degrees C. In kidney, enhanced zones on T1-weighted images did not match the isotherms. CONCLUSION The liposomal contrast agent was effective at in vivo MR thermometry in liver but not in kidney.
Collapse
Affiliation(s)
- Nathan McDannold
- Department of Radiology, Harvard Medical School and Brigham and Women's Hospital, 221 Longwood Ave, LMRC 007C, Boston, MA 02115, USA.
| | | | | | | | | | | |
Collapse
|