Castelein J, Pamplona C, Armstrong Junior R, Vidal dos Santos M, Sack I, Dierckx R, Moers C, Borra R. Effects of kidney perfusion on renal stiffness and tissue fluidity measured with tomoelastography in an MRI-compatible ex vivo model. Front Bioeng Biotechnol 2023; 11:1236949. [PMID: 38026891 PMCID: PMC10665518 DOI: 10.3389/fbioe.2023.1236949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Accepted: 10/27/2023] [Indexed: 12/01/2023] Open
Abstract
Stiffness plays a vital role in diagnosing renal fibrosis. However, perfusion influences renal stiffness in various chronic kidney diseases. Therefore, we aimed to characterize the effect of tissue perfusion on renal stiffness and tissue fluidity measured by tomoelastography based on multifrequency magnetic resonance elastography in an ex vivo model. Five porcine kidneys were perfused ex vivo in an MRI-compatible normothermic machine perfusion setup with adjusted blood pressure in the 50/10-160/120 mmHg range. Simultaneously, renal cortical and medullary stiffness and fluidity were obtained by tomoelastography. For the cortex, a statistically significant (p < 0.001) strong positive correlation was observed between both perfusion parameters (blood pressure and resulting flow) and stiffness (r = 0.95, 0.91), as well as fluidity (r = 0.96, 0.92). For the medulla, such significant (p < 0.001) correlations were solely observed between the perfusion parameters and stiffness (r = 0.88, 0.71). Our findings demonstrate a strong perfusion dependency of renal stiffness and fluidity in an ex vivo setup. Moreover, changes in perfusion are rapidly followed by changes in renal mechanical properties-highlighting the sensitivity of tomoelastography to fluid pressure and the potential need for correcting mechanics-derived imaging biomarkers when addressing solid structures in renal tissue.
Collapse
Affiliation(s)
- Johannes Castelein
- Department of Radiology & Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen, Netherlands
- Department for Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Carolina Pamplona
- Department of Surgery, University Medical Center Groningen, Groningen, Netherlands
| | | | | | - Ingolf Sack
- Department of Radiology, Charité University Medicine Berlin, Berlin, Germany
| | - Rudi Dierckx
- Department of Radiology & Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen, Netherlands
| | - Cyril Moers
- Department of Surgery, University Medical Center Groningen, Groningen, Netherlands
| | - Ronald Borra
- Department of Radiology & Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen, Netherlands
| |
Collapse
|
2
|
Caroli A, Kline TL. Abdominal Imaging in ADPKD: Beyond Total Kidney Volume. J Clin Med 2023; 12:5133. [PMID: 37568535 PMCID: PMC10420262 DOI: 10.3390/jcm12155133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 08/02/2023] [Accepted: 08/03/2023] [Indexed: 08/13/2023] Open
Abstract
In the context of autosomal dominant polycystic kidney disease (ADPKD), measurement of the total kidney volume (TKV) is crucial. It acts as a marker for tracking disease progression, and evaluating the effectiveness of treatment strategies. The TKV has also been recognized as an enrichment biomarker and a possible surrogate endpoint in clinical trials. Several imaging modalities and methods are available to calculate the TKV, and the choice depends on the purpose of use. Technological advancements have made it possible to accurately assess the cyst burden, which can be crucial to assessing the disease state and helping to identify rapid progressors. Moreover, the development of automated algorithms has increased the efficiency of total kidney and cyst volume measurements. Beyond these measurements, the quantification and characterization of non-cystic kidney tissue shows potential for stratifying ADPKD patients early on, monitoring disease progression, and possibly predicting renal function loss. A broad spectrum of radiological imaging techniques are available to characterize the kidney tissue, showing promise when it comes to non-invasively picking up the early signs of ADPKD progression. Radiomics have been used to extract textural features from ADPKD images, providing valuable information about the heterogeneity of the cystic and non-cystic components. This review provides an overview of ADPKD imaging biomarkers, focusing on the quantification methods, potential, and necessary steps toward a successful translation to clinical practice.
Collapse
Affiliation(s)
- Anna Caroli
- Bioengineering Department, Istituto di Ricerche Farmacologiche Mario Negri IRCCS, 24020 Ranica, BG, Italy
| | | |
Collapse
|
3
|
Abstract
ABSTRACT The mechanical traits of cancer include abnormally high solid stress as well as drastic and spatially heterogeneous changes in intrinsic mechanical tissue properties. Whereas solid stress elicits mechanosensory signals promoting tumor progression, mechanical heterogeneity is conducive to cell unjamming and metastatic spread. This reductionist view of tumorigenesis and malignant transformation provides a generalized framework for understanding the physical principles of tumor aggressiveness and harnessing them as novel in vivo imaging markers. Magnetic resonance elastography is an emerging imaging technology for depicting the viscoelastic properties of biological soft tissues and clinically characterizing tumors in terms of their biomechanical properties. This review article presents recent technical developments, basic results, and clinical applications of magnetic resonance elastography in patients with malignant tumors.
Collapse
Affiliation(s)
- Jing Guo
- From the Department of Radiology
| | | | | | | |
Collapse
|
4
|
Yoon JS, Lim KJ, Hwang IT. Usefulness of two-dimensional shear wave elastography in the assessment of non-alcoholic fatty liver disease in children and adolescents. Sci Rep 2023; 13:10062. [PMID: 37344574 DOI: 10.1038/s41598-023-37281-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Accepted: 06/19/2023] [Indexed: 06/23/2023] Open
Abstract
Two-dimensional shear wave elastography (2D-SWE) evaluates liver stiffness using a non-invasive method, but studies in the paediatric population are rare. This study evaluated the role of 2D-SWE in the diagnosis and severity of paediatric non-alcoholic fatty liver disease (NAFLD). In total, 131 patients with NAFLD and 25 healthy controls were enrolled in this study. The diagnosis and severity of NAFLD were initially assessed using the ultrasound fatty liver index (US-FLI), and all participants underwent 2D-SWE. US-FLI semi-quantitatively measures the severity of NAFLD on a scale of 2-8. The assessment of liver stiffness measurement (LSM) by 2D-SWE is presented in kilopascals (kPa). The NAFLD group was characterised by significantly higher LSM (4.40 ± 0.90 kPa) than the control group (3.76 ± 0.28 kPa) (P < 0.001). 2D-SWE significantly correlated with age, height, weight, body mass index, glucose, aspartate aminotransferase, alanine aminotransferase, high-density lipoprotein cholesterol, US-FLI, and triglyceride-glucose index (P < 0.001). In the receiver operating characteristic curve analysis, the area under the curve of LSM for predicting US-FLI ≥ 2 and ≥ 6 was 0.784 (P < 0.001) and 0.819 (P < 0.001), respectively. In conclusion, we suggest that 2D-SWE can be used as a non-invasive diagnostic tool for diagnosing and assessing the severity of paediatric NAFLD.
Collapse
Affiliation(s)
- Jong Seo Yoon
- Department of Paediatrics, Hallym University Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul, South Korea
| | - Kyoung Ja Lim
- Department of Radiology, Hallym University Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul, 05355, South Korea.
| | - Il Tae Hwang
- Department of Paediatrics, Hallym University Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul, South Korea
| |
Collapse
|
5
|
Herthum H, Hetzer S, Kreft B, Tzschätzsch H, Shahryari M, Meyer T, Görner S, Neubauer H, Guo J, Braun J, Sack I. Cerebral tomoelastography based on multifrequency MR elastography in two and three dimensions. Front Bioeng Biotechnol 2022; 10:1056131. [PMID: 36532573 PMCID: PMC9755504 DOI: 10.3389/fbioe.2022.1056131] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Accepted: 11/21/2022] [Indexed: 09/01/2023] Open
Abstract
Purpose: Magnetic resonance elastography (MRE) generates quantitative maps of the mechanical properties of biological soft tissues. However, published values obtained by brain MRE vary largely and lack detail resolution, due to either true biological effects or technical challenges. We here introduce cerebral tomoelastography in two and three dimensions for improved data consistency and detail resolution while considering aging, brain parenchymal fraction (BPF), systolic blood pressure, and body mass index (BMI). Methods: Multifrequency MRE with 2D- and 3D-tomoelastography postprocessing was applied to the brains of 31 volunteers (age range: 22-61 years) for analyzing the coefficient of variation (CV) and effects of biological factors. Eleven volunteers were rescanned after 1 day and 1 year to determine intraclass correlation coefficient (ICC) and identify possible long-term changes. Results: White matter shear wave speed (SWS) was slightly higher in 2D-MRE (1.28 ± 0.02 m/s) than 3D-MRE (1.22 ± 0.05 m/s, p < 0.0001), with less variation after 1 day in 2D (0.33 ± 0.32%) than in 3D (0.96 ± 0.66%, p = 0.004), which was also reflected in a slightly lower CV and higher ICC in 2D (1.84%, 0.97 [0.88-0.99]) than in 3D (3.89%, 0.95 [0.76-0.99]). Remarkably, 3D-MRE was sensitive to a decrease in white matter SWS within only 1 year, whereas no change in white matter volume was observed during this follow-up period. Across volunteers, stiffness correlated with age and BPF, but not with blood pressure and BMI. Conclusion: Cerebral tomoelastography provides high-resolution viscoelasticity maps with excellent consistency. Brain MRE in 2D shows less variation across volunteers in shorter scan times than 3D-MRE, while 3D-MRE appears to be more sensitive to subtle biological effects such as aging.
Collapse
Affiliation(s)
- Helge Herthum
- Berlin Center for Advanced Neuroimaging, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
- Bernstein Center for Computational Neuroscience, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
- Institute of Medical Informatics, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Stefan Hetzer
- Berlin Center for Advanced Neuroimaging, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
- Bernstein Center for Computational Neuroscience, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Bernhard Kreft
- Department of Radiology, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Heiko Tzschätzsch
- Department of Radiology, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Mehrgan Shahryari
- Department of Radiology, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Tom Meyer
- Department of Radiology, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Steffen Görner
- Department of Radiology, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Hennes Neubauer
- Department of Radiology, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Jing Guo
- Department of Radiology, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Jürgen Braun
- Institute of Medical Informatics, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Ingolf Sack
- Department of Radiology, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| |
Collapse
|
6
|
Song Q, Shi Y, Gao F, Yin M, Yang R, Liu Y, Zhong S, Hong Y. Feasibility and Reproducibility of Multifrequency Magnetic Resonance Elastography in Healthy and Diseased Pancreases. J Magn Reson Imaging 2022; 56:1769-1780. [PMID: 35332973 PMCID: PMC9509497 DOI: 10.1002/jmri.28158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 03/02/2022] [Accepted: 03/04/2022] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND The feasibility and reproducibility of multifrequency MR elastography (MRE) for diagnosing pancreatic ductal adenocarcinoma (PDAC) have not been reported. PURPOSE To determine the feasibility and reproducibility of multifrequency MRE for assessing pancreatic stiffness in healthy and diseased pancreases. STUDY TYPE Prospective. SUBJECTS A total of 40 healthy volunteers and 10 patients with PDAC were prospectively recruited between March 2018 and October 2021. FIELD STRENGTH/SEQUENCE A 3.0-T pancreatic MRE at frequencies in the order of 30, 40, 60, 80, and 100 Hz. ASSESSMENT Body mass index (BMI) and wave distance of the healthy pancreas and PDAC were measured. Image quality was assessed using the image quality score (IQS: 1-4, ≥3 were considered diagnostic quality). Three readers independently performed the pancreatic stiffness and IQS assessments to evaluate reproducibility. STATISTICAL TESTS Logistic regression analyses were performed to determine variables that influenced IQS. Statistical significance was set at P <0.05. Levels of inter- and intrarater agreement were assessed using intraclass correlation coefficients (ICC) and Cohen's kappa coefficient (κ). Good reproducibility was set at ICC and κ ≥ 0.8. RESULTS In logistic regression analysis, a diagnostic IQS in healthy volunteers was independently associated with a lower BMI (odds ratio [OR] = 0.89 kg/m-2 ), shorter wave distance (OR = 0.70 cm-1 ), and lower frequency (30 and 40 Hz: OR = 170.01 and 96.02). In PDAC, frequency was the only independent factor for diagnostic IQS (30-60 Hz: OR = 46.18, 46.18, and 17.20, respectively) with 100 Hz as a reference. In healthy volunteers, good reproducibility was observed at 30 and 40 Hz. In PDAC, good reproducibility was observed at 30-60 Hz. DATA CONCLUSION MRE at 30 and 40 Hz provides diagnostic wave images and reliable measurements of pancreatic stiffness in healthy volunteers. MRE at 30-60 Hz is acceptable for PDACs (IQS ≥ 3, ICC and κ ≥ 0.80). EVIDENCE LEVEL 1 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Qike Song
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, P.R. China
| | - Yu Shi
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, P.R. China
| | - Feng Gao
- Department of Pancreato-thyroidic Surgery, Shengjing Hospital of China Medical University, Shenyang, P.R. China
| | - Meng Yin
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Rui Yang
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, P.R. China
| | - Yuanyuan Liu
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, P.R. China
| | - Shiling Zhong
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, P.R. China
| | - Yang Hong
- Department of Neurosurgery, Shengjing Hospital of China Medical University, Shenyang, P.R. China
| |
Collapse
|
7
|
Li Y, Gao Q, Chen N, Zhang Y, Wang J, Li C, He X, Jiao Y, Zhang Z. Clinical studies of magnetic resonance elastography from 1995 to 2021: Scientometric and visualization analysis based on CiteSpace. Quant Imaging Med Surg 2022; 12:5080-5100. [PMID: 36330182 PMCID: PMC9622435 DOI: 10.21037/qims-22-207] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Accepted: 08/11/2022] [Indexed: 02/05/2023]
Abstract
BACKGROUND To assess the knowledge framework around magnetic resonance elastography (MRE) and to explore MRE research hotspots and emerging trends. METHODS The Science Citation Index Expanded of the Web of Science Core Collection was searched on 22 October 2021 for MRE-related studies published between 1995 and 2021. Excel 2016 and CiteSpace V (version 5.8.R3) were used to analyze the downloaded data. RESULTS In all, 1,236 articles published by 726 authors from 540 institutions in 40 countries were included in this study. The top 10 authors published 57.6% of all included articles. The 3 most productive countries were the USA (n=631), Germany (n=202), and France (n=134), and the 3 most productive institutions were the Mayo Clinic (n=240), Charité (n=131), and the University of Illinois (n=56). The USA and the Mayo Clinic had the highest betweenness centrality among countries and institutions, respectively, and played an important role in the field of MRE. In this study, the 24,347 distinct references were clustered into 48 categories via reasonable clustering using specific keywords, forming the knowledge framework. Among the 294 co-occurring keywords, "hepatic fibrosis", "stiffness", "skeletal muscle", "acoustic strain wave", "in vivo", and "non-invasive assessment" were research hotspots. "Diagnostic performance", "diagnostic accuracy", "hepatic steatosis", "chronic hepatitis B", "radiation force impulse", "children", and "echo" were frontier topics. CONCLUSIONS Scientometric and visualized analysis of MRE can provide information regarding the knowledge framework, research hotspots, frontier areas, and emerging trends in this field.
Collapse
Affiliation(s)
- Youwei Li
- Department of Radiology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Qiang Gao
- Department of Gastroenterology and Hepatology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Na Chen
- Department of Otorhinolaryngology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Yuanfang Zhang
- Department of Radiology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Juan Wang
- Department of Radiology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Chang Li
- Department of Radiology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Xuan He
- Department of Radiology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Yang Jiao
- Department of Rehabilitation Psychology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Zongming Zhang
- Department of General Surgery, Beijing Electric Power Hospital, State Grid Corporation of China, Capital Medical University, Beijing, China
| |
Collapse
|
8
|
Yiyi M, Xiaoqin Q, Lei Z. Spleen Stiffness on Magnetic Resonance Elastography for the Detection of Portal Hypertension: A Systematic Review and Meta-Analysis. IRANIAN JOURNAL OF PUBLIC HEALTH 2022; 51:1925-1935. [PMID: 36743372 PMCID: PMC9884383 DOI: 10.18502/ijph.v51i9.10548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Accepted: 06/18/2022] [Indexed: 11/24/2022]
Abstract
Background Chronic liver disease, complicated by portal hypertension (PH), may alter the extra-hepatic hemodynamic condition and spleen stiffness (SS). We aimed to evaluate the diagnostic accuracy of MRI-based elastographic methods (MRE) for detecting PH. Methods Seven studies were included with reference to SS with regard to the prediction of PH patients. Major outcomes considered for data extraction were diagnostic parameters for MRI for concluding mild PH, clinically significant PH and severe PH. PubMed, Scopus, Google Scholar, Cochrane and Science Direct databases were used to extract the published literature through to May, 2021Using the Rayyan Zotero and R softwares. Results Out of 587 studies extracted, 7 were selected based on inclusion and exclusion criteria. A QUADAS-2 assessment showed that all studies were clear in terms of patient selection and reference standard. A funnel plot showed that all the selected studies were outliers, indicating a low level of accuracy for the studies included. Subgroup analysis, with reference to SS as a predictor of PH, revealed raw mean difference (RMD) of 7.78% (95% CI 5.23-10.34, P<0.01). The corresponding RMD observed for <60 years and >60 yr were 34.26% (95% CI 9.33- 59.20, I2=100%, τ2=646.7688, P=0), and 46.92% (95% CI 20-59.33, I2=97%, τ2=1003.023, P=0) respectively. The specificity and sensitivity noted for MRI in determining SS were 0.721 and 0.747, respectively with an area-under the curve of 0.788. The estimated random effect models for specificity and sensitivity were 0.938 and 0.842, respectively. Conclusion The real-time MRE has acceptable specificity and sensitivity for diagnosing SS.
Collapse
Affiliation(s)
- Ma Yiyi
- Department of Ultrasound, Affiliated Hospital of Jiangnan University, Wuxi, Jiangsu Province, 214000, China
| | - Qian Xiaoqin
- Department of Ultrasound, Affiliated Hospital of Jiangnan University, Wuxi, Jiangsu Province, 214000, China
| | - Zhang Lei
- Department of Ultrasound, Affiliated Hospital of Jiangnan University, Wuxi, Jiangsu Province, 214000, China,Corresponding Author:
| |
Collapse
|
9
|
Magnetic Resonance Elastography-derived Stiffness Predicts Renal Function Loss and Is Associated With Microvascular Inflammation in Kidney Transplant Recipients. Transplant Direct 2022; 8:e1334. [PMID: 35721457 PMCID: PMC9197345 DOI: 10.1097/txd.0000000000001334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Revised: 04/08/2022] [Accepted: 04/12/2022] [Indexed: 11/26/2022] Open
Abstract
Background. Organ stiffening can be caused by inflammation and fibrosis, processes that are common causes of transplant kidney dysfunction. Magnetic resonance elastography (MRE) is a contrast-free, noninvasive imaging modality that measures kidney stiffness. The objective of this study was to assess the ability of MRE to serve as a prognostic factor for renal outcomes. Methods. Patients were recruited from the St Michael’s Hospital Kidney Transplant Clinic. Relevant baseline demographic, clinical, and Banff histologic information, along with follow-up estimated glomerular filtration rate (eGFR) data, were recorded. Two-dimensional gradient-echo MRE imaging was performed to obtain kidney “stiffness” maps. Binary logistic regression analyses were performed to examine for relationships between stiffness and microvascular inflammation score. Linear mixed-effects modeling was used to assess the relationship between stiffness and eGFR change over time controlling for other baseline variables. A G2-likelihood ratio Chi-squared test was performed to compare between the baseline models with and without “stiffness.” Results. Sixty-eight transplant kidneys were scanned in 66 patients (mean age 56 ± 12 y, 24 females), with 38 allografts undergoing a contemporaneous biopsy. Mean transplant vintage was 7.0 ± 6.8 y. In biopsied allografts, MRE-derived allograft stiffness was associated only with microvascular inflammation (Banff g + ptc score, Spearman ρ = 0.43, P = 0.01), but no other histologic parameters. Stiffness was negatively associated with eGFR change over time (Stiffness × Time interaction β = –0.80, P < 0.0001), a finding that remained significant even when adjusted for biopsy status and baseline variables (Stiffness × Time interaction β = –0.46, P = 0.04). Conversely, the clinical models including “stiffness” showed significantly better fit (P = 0.04) compared with the baseline clinical models without “stiffness.” Conclusions. MRE-derived renal stiffness provides important prognostic information regarding renal function loss for patients with allograft dysfunction, over and above what is provided by current clinical variables.
Collapse
|
10
|
Herthum H, Carrillo H, Osses A, Uribe S, Sack I, Bertoglio C. Multiple motion encoding in phase-contrast MRI: A general theory and application to elastography imaging. Med Image Anal 2022; 78:102416. [PMID: 35334444 DOI: 10.1016/j.media.2022.102416] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 12/23/2021] [Accepted: 03/01/2022] [Indexed: 01/04/2023]
Abstract
While MRI allows to encode the motion of tissue in the magnetization's phase, it remains yet a challenge to obtain high fidelity motion images due to wraps in the phase for high encoding efficiencies. Therefore, we propose an optimal multiple motion encoding method (OMME) and exemplify it in Magnetic Resonance Elastography (MRE) data. OMME is formulated as a non-convex least-squares problem for the motion using an arbitrary number of phase-contrast measurements with different motion encoding gradients (MEGs). The mathematical properties of OMME are proved in terms of standard deviation and dynamic range of the motion's estimate for arbitrary MEGs combination which are confirmed using synthetically generated data. OMME's performance is assessed on MRE data from in vivo human brain experiments and compared to dual encoding strategies. The unwrapped images are further used to reconstruct stiffness maps and compared to the ones obtained using conventional unwrapping methods. OMME allowed to successfully combine several MRE phase images with different MEGs, outperforming dual encoding strategies in either motion-to-noise ratio (MNR) or number of successfully reconstructed voxels with good noise stability. This lead to stiffness maps with greater resolution of details than obtained with conventional unwrapping methods. The proposed OMME method allows for a flexible and noise robust increase in the dynamic range and thus provides wrap-free phase images with high MNR. In MRE, the method may be especially suitable when high resolution images with high MNR are needed.
Collapse
Affiliation(s)
- Helge Herthum
- Institute of Medical Informatics, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universitt zu Berlin, and Berlin Institute of Health, Berlin, 10117, Germany
| | - Hugo Carrillo
- Center for Mathematical Modeling, Universidad de Chile, Santiago, 8370456, Chile; Bernoulli Institute, University of Groningen, Groningen, 9747AG, the Netherlands
| | - Axel Osses
- Center for Mathematical Modeling, Universidad de Chile, Santiago, 8370456, Chile; Department of Mathematical Engineering, Universidad de Chile, Santiago, 8370456, Chile; ANID - Millennium Nucleus in Cardiovascular Magnetic Resonance, Santiago, 7820436, Chile; ANID - Millenium Nucleus in Applied Control and Inverse Problems ACIP, Santiago, 7820436, Chile
| | - Sergio Uribe
- ANID - Millennium Nucleus in Cardiovascular Magnetic Resonance, Santiago, 7820436, Chile; Biomedical Imaging Center, Pontificia Universidad Católica de Chile, Santiago, 7820436, Chile
| | - Ingolf Sack
- Institute of Medical Informatics, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universitt zu Berlin, and Berlin Institute of Health, Berlin, 10117, Germany
| | - Cristóbal Bertoglio
- Bernoulli Institute, University of Groningen, Groningen, 9747AG, the Netherlands.
| |
Collapse
|
11
|
Pednekar A, Gandhi D, Wang H, Tkach JA, Trout AT, Dillman JR. Performance of C-SENSE Accelerated Rapid Liver Shear Stiffness Measurement Using Displacement Wave Polarity-Inversion Motion Encoding: An Evaluation Study. J Magn Reson Imaging 2022; 56:754-765. [PMID: 35089614 DOI: 10.1002/jmri.28078] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Revised: 01/10/2022] [Accepted: 01/11/2022] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND Liver shear stiffness measurement using magnetic resonance elastography (MRE) aids in the noninvasive diagnosis and staging of liver fibrosis. Inadequate breath-holds can lead to inaccurate stiffness estimation and/or failed MRE exams. PURPOSE To prospectively evaluate the performance of compressed sensitivity encoding (C-SENSE) accelerated rapid MRE measurement of liver shear stiffness using displacement wave polarity-inversion motion encoding. STUDY TYPE Retrospective. SUBJECTS Eleven with liver disease and 10 asymptomatic subjects. FIELD STRENGTH/SEQUENCE 1.5 T; gradient-recalled-echo (GRE) MRE. ASSESSMENT All participants underwent: 1) two-dimensional (2D) GRE MRE with inflow saturation using SENSE acceleration factor (R) of 2 (standard of care [SC]); 2) 2D rapid MRE with (RwS); and 3) without (RnS) inflow saturation using C-SENSE R = 3; and 4) spatial three-dimensional (3D) rapid MRE with inflow saturation (R3D) using C-SENSE R = 4; with nominally identical spatial resolution and coverage. Image analyst (D.G., 2 years of experience) drew identical and maximal regions of interest (ROIs) in right hepatic lobe. STATISTICAL TESTS Linear regression, intra-class correlation coefficients (ICC), Bland-Altman analyses, and the Wilcoxon signed-rank test were used to assess consistency and agreement of liver stiffness measurements for manually drawn identical and maximal ROIs. RESULTS In 21 participants (37 ± 14 years) with liver stiffness (2.3 ± 0.7 kPa), body mass index (BMI 27 ± 7 kg/m2 ), proton density fat fraction (PDFF 9 ± 9%), and T2 * (27 ± 4 msec); rapid MRE sequences showed excellent agreement (ICC > 0.95) with SC MRE and no correlation (r2 < 0.1) of the differences (mean difference <0.2 kPa, <6%; limits of agreement <0.4 kPa, <16%) with BMI, PDFF, and T2 *. Breath-hold times were: 14 seconds (SC), 5 seconds (RnS), 7 seconds (RwS) per slice, and 16 seconds for the R3D acquisition. DATA CONCLUSIONS C-SENSE accelerated GRE MRE sequences, using displacement wave polarity-inversion motion encoding, produce equivalent measurements of liver stiffness and have potential clinical benefit in patients with limited breath-holding capacity. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Amol Pednekar
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.,Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| | - Deep Gandhi
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.,Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| | - Hui Wang
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.,Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA.,MR Clinical Science, Philips, Cincinnati, Ohio, USA
| | - Jean A Tkach
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.,Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| | - Andrew T Trout
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.,Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| | - Jonathan R Dillman
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.,Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| |
Collapse
|
12
|
Kamezawa C, Cramer A, Krull W, Yashiro W, Hyodo K, Gupta R. Dynamic X-ray elastography using a pulsed photocathode source. Sci Rep 2021; 11:24128. [PMID: 34916531 PMCID: PMC8677743 DOI: 10.1038/s41598-021-03221-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Accepted: 10/20/2021] [Indexed: 11/24/2022] Open
Abstract
X-ray absorption of breast cancers and surrounding healthy tissue can be very similar, a situation that sometimes leads to missed cancers or false-positive diagnoses. To increase the accuracy of mammography and breast tomosynthesis, we describe dynamic X-ray elastography using a novel pulsed X-ray source. This new imaging modality provides both absorption and mechanical properties of the imaged material. We use a small acoustic speaker to vibrate the sample while a synchronously pulsed cold cathode X-ray source images the mechanical deformation. Using these stroboscopic images, we derive two-dimensional stiffness maps of the sample in addition to the conventional X-ray image. In a breast phantom composed of ZrO2 powder embedded in gel, dynamic elastography derived stiffness maps were able to discriminate a hard inclusion from surrounding material with a contrast-to-noise ratio (CNR) of 4.5. The CNR on the corresponding absorption image was 1.1. This demonstrates the feasibility of dynamic X-ray elastography with a synchronously pulsed X-ray source.
Collapse
Affiliation(s)
- Chika Kamezawa
- Department of Materials Structure Science, SOKENDAI (The Graduate University for Advanced Studies), 1-1 Oho, Tsukuba, Ibaraki, 305-0801, Japan
- Institute of Materials Structure Science, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki, 305-0801, Japan
- Institute of Multidisciplinary Research for Advanced Materials (IMRAM), Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, Miyagi, 980-8577, Japan
| | - Avilash Cramer
- Massachusetts Institute of Technology, Cambridge, 02139, USA
- Harvard Medical School, Boston, 20115, USA
| | | | - Wataru Yashiro
- Institute of Multidisciplinary Research for Advanced Materials (IMRAM), Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, Miyagi, 980-8577, Japan
| | - Kazuyuki Hyodo
- Department of Materials Structure Science, SOKENDAI (The Graduate University for Advanced Studies), 1-1 Oho, Tsukuba, Ibaraki, 305-0801, Japan
- Institute of Materials Structure Science, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki, 305-0801, Japan
| | - Rajiv Gupta
- Harvard Medical School, Boston, 20115, USA.
- Massachusetts General Hospital, Boston, 02114, USA.
| |
Collapse
|
13
|
Qiu S, He Z, Wang R, Li R, Zhang A, Yan F, Feng Y. An electromagnetic actuator for brain magnetic resonance elastography with high frequency accuracy. NMR IN BIOMEDICINE 2021; 34:e4592. [PMID: 34291510 DOI: 10.1002/nbm.4592] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2021] [Revised: 06/07/2021] [Accepted: 07/06/2021] [Indexed: 06/13/2023]
Abstract
Our goal is to design, test and verify an electromagnetic actuator for brain magnetic resonance elastography (MRE). We proposed a grappler-shaped design that can transmit stable vibrations into the brain. To validate its performance, simulations were carried out to ensure the electromagnetic field generated by the actuator did not interfere with the B0 field. The actuation vibration spectrum was analyzed to verify the actuation accuracy. Phantom and volunteer experiments were carried out to evaluate the performance of the actuator. Simulation of the magnetic field showed that the proposed actuator has a fringe field of less than 3 G in the imaging region. The phantom experiments showed that the proposed actuator did not interfere with the routine imaging sequences. The measured vibration spectra demonstrated that the frequency offset was about one third that of a pneumatic device and the transmission efficiency was three times higher. The shear moduli estimated from brain MRE were consistent with those from the literature. The actuation frequency of the proposed actuator has less frequency offset and off-center frequency components compared with the pneumatic counterpart. The whole actuator weighted only 980 g. The actuator can carry out multifrequency MRE on the brain with high accuracy. It is easy to use, comfortable for the patient and portable.
Collapse
Affiliation(s)
- Suhao Qiu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Zhao He
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Runke Wang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Ruokun Li
- Department of Radiology, Ruijin Hospital, Shanghai, China
| | - Aili Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Fuhua Yan
- Department of Radiology, Ruijin Hospital, Shanghai, China
| | - Yuan Feng
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
14
|
Extracellular Matrix Components as Diagnostic Tools in Inflammatory Bowel Disease. BIOLOGY 2021; 10:biology10101024. [PMID: 34681123 PMCID: PMC8533508 DOI: 10.3390/biology10101024] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Revised: 09/14/2021] [Accepted: 09/30/2021] [Indexed: 12/20/2022]
Abstract
Simple Summary For decades, the extracellular matrix (ECM) has been defined as a structure component playing a rather neglected role in the human body. In recent years, research has shed light on the role of ECM within cellular processes, including proliferation, migration and differentiation, as well as in inflammation. In inflammation, ECM composition is constantly being remodeled and undergoes dynamic and rapid changes. Tracking these changes could serve as a novel diagnostic tool. Inflammatory bowel disease is accompanied by complications such as fibrosis, stenosis and fistulas. All of these structural complications involve excessive synthesis or degradation of ECM. With this review, we explored whether the analysis of ECM composition can be of support in diagnosing inflammatory bowel disease and whether changes within ECM can help to predict a complicated disease course early on. Abstract Work from the last years indicates that the extracellular matrix (ECM) plays a direct role in various cellular processes, including proliferation, migration and differentiation. Besides homeostatic processes, its regulatory function in inflammation becomes more and more evident. In inflammation, such as inflammatory bowel disease, the ECM composition is constantly remodeled, and this can result in a structuring of fistulizing disease course. Thus, tracking early ECM changes might bear the potential to predict the disease course. In this review, we provide an overview of relevant diagnostic methods, focusing on ECM changes.
Collapse
|
15
|
Obrzut M, Atamaniuk V, Chen J, Obrzut B, Ehman RL, Cholewa M, Palusińska A, Gutkowski K. Postprandial hepatic stiffness changes on magnetic resonance elastography in healthy volunteers. Sci Rep 2021; 11:19786. [PMID: 34611231 PMCID: PMC8492759 DOI: 10.1038/s41598-021-99243-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Accepted: 09/14/2021] [Indexed: 11/23/2022] Open
Abstract
Magnetic resonance elastography (MRE) is a reliable noninvasive method for assessment of hepatic stiffness. Liver stiffness is known to be affected by elevated postprandial portal blood flow in patients with chronic liver disease. The goal of this study was to determine whether food intake affects liver stiffness in the absence of known liver disease. We evaluated 100 volunteers (35 men and 65 women) who met inclusion criteria. The subjects had two MRE examinations, first while fasting and then 30 min after a test meal. Fourteen subjects also had two additional MRE exams 1 h 30 min and 2 h 30 min after the meal. Liver stiffness was measured by placing the largest possible polygon ROIs on the four widest liver slices and calculated as a mean of stiffness values from each slice. The correlation of liver stiffness values before and after the meal was assessed using a paired t-test. To evaluate the relationship between the change in postprandial liver stiffness and fasting liver stiffness values, linear regression was performed. The liver stiffness values in the fasting state ranged from 1.84 to 2.82 kPa, with a mean of 2.30 ± 0.23 kPa (95% CI 2.25–2.34). At 30 min after the meal, liver stiffness values ranged from 2.12 to 3.50 kPa, with a mean of 2.70 ± 0.28 kPa (95% CI 2.64–2.75), demonstrating a systematic postprandial increase by 0.40 ± 0.23 kPa (17.7 ± 3.5%). Meal intake significantly increases liver stiffness in healthy individuals, which persists for at least 2 h 30 min. Patients should fast for 3–4 h before MRE examinations to avoid fibrosis overstaging due to postprandial liver stiffness augmentation.
Collapse
Affiliation(s)
- Marzanna Obrzut
- Institute of Health Sciences, Medical College, University of Rzeszow, Rzeszow, Poland
| | - Vitaliy Atamaniuk
- Department of Biophysics, College of Natural Sciences, Institute of Physics, University of Rzeszow, aleja Tadeusza Rejtana 16C, 35-959, Rzeszow, Poland.
| | - Jun Chen
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Bogdan Obrzut
- Department of Obstetrics and Gynecology, Institute of Medical Sciences, Medical College, University of Rzeszow, Rzeszow, Poland
| | | | - Marian Cholewa
- Department of Biophysics, College of Natural Sciences, Institute of Physics, University of Rzeszow, aleja Tadeusza Rejtana 16C, 35-959, Rzeszow, Poland
| | - Agnieszka Palusińska
- Department of Internal Medicine and Nephrodiabetology, Medical University of Lodz, Lodz, Poland
| | - Krzysztof Gutkowski
- Institute of Medical Sciences, Medical College, University of Rzeszow, Rzeszow, Poland
| |
Collapse
|
16
|
Plaikner M, Kremser C, Zoller H, Kannengiesser S, Henninger B. MR elastography in patients with suspected diffuse liver disease at 1.5T: Intraindividual comparison of gradient-recalled echo versus spin-echo echo-planar imaging sequences and investigation of potential confounding factors. Eur J Radiol 2021; 142:109898. [PMID: 34388628 DOI: 10.1016/j.ejrad.2021.109898] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 07/30/2021] [Accepted: 08/03/2021] [Indexed: 12/16/2022]
Abstract
PURPOSE To compare liver stiffness (LS) in patients with suspected diffuse liver disease between gradient-recalled-echo magnetic resonance elastography (GRE-MRE) and different spin-echo echo-planar imaging (SE-EPI-MRE) sequences and to investigate confounding factors including fat, iron, age, and sex. METHOD LS was measured at 1.5T using GRE-MRE, SE-EPI-MRE and short-TE-SE-EPI-MRE (hiSE-EPI-MRE) sequences and compared using Bland-Altman-plots together with concordance correlation coefficients (CCC). Success gradings were evaluated considering possible confounding factors. RESULTS 305 patients (225 male, 80 females, mean age 51.12 years) were included. 109/305 showed hepatic iron overload, 183 hepatic steatosis. The mean difference (bias) in stiffness values between GRE-MRE and SE-EPI-MRE/hiSE-EPI-MRE was 0.15/0.2 kPa (LOA: -0.72,0.41 kPa/-0.94,0.55 kPa), between SE-EPI-MRE and hiSE-EPI-MRE 0.04 kPa (LOA: -0.62,0.53 kPa). The CCC for agreement between stiffness values for GRE-MRE and SE-EPI-MRE was 0.94 (0.92-0.95), 0.89 (0.86-0.91) for hiSE-EPI-MRE and GRE-MRE and 0.94 (0.92-0.95) for SE-EPI-MRE and hiSE-EPI-MRE. Using GRE-MRE, 72/305 showed unusable results whereby all these patients had high iron levels (mean R2*=209.7 1/s). For SE-EPI-MRE and hiSE-EPI-MRE only 10/305 and 8/305 were inconclusive respectively, corresponding to a significantly higher iron load (mean R2*= 549.2 1/s for SE-EPI-MRE and 570.7 1/s for hiSE-EPI-MRE). Concerning fat, age or sex no significant influence on success was observed for all sequences. CONCLUSIONS Good agreement of LS values was observed between GRE-MRE and SE-EPI-MRE sequences. The number of successful exams, however, was considerably lower for GRE-MRE, mainly due to iron content. Study reference number: AN5093.
Collapse
Affiliation(s)
- Michaela Plaikner
- Medical University of Innsbruck, Department of Radiology, Innsbruck, Austria
| | - Christian Kremser
- Medical University of Innsbruck, Department of Radiology, Innsbruck, Austria.
| | - Heinz Zoller
- Medical University of Innsbruck, Department of Internal Medicine, Innsbruck, Austria
| | | | - Benjamin Henninger
- Medical University of Innsbruck, Department of Radiology, Innsbruck, Austria
| |
Collapse
|
17
|
Gandhi DB, Pednekar A, Braimah AB, Dudley J, Tkach JA, Trout AT, Miethke AG, Franck MD, Heilman JA, Dzyubak B, Lake DS, Dillman JR. Assessment of agreement between manual and automated processing of liver MR elastography for shear stiffness estimation in children and young adults with autoimmune liver disease. Abdom Radiol (NY) 2021; 46:3927-3934. [PMID: 33811261 DOI: 10.1007/s00261-021-03073-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 03/17/2021] [Accepted: 03/21/2021] [Indexed: 12/30/2022]
Abstract
PURPOSE To compare automated versus standard of care manual processing of 2D gradient recalled echo (GRE) liver MR Elastography (MRE) in children and young adults. MATERIALS AND METHODS 2D GRE liver MRE data from research liver MRI examinations performed as part of an autoimmune liver disease registry between March 2017 and March 2020 were analyzed retrospectively. All liver MRE data were acquired at 1.5 T with 60 Hz mechanical vibration frequency. For manual processing, two independent readers (R1, R2) traced regions of interest on scanner generated shear stiffness maps. Automated processing was performed using MREplus+ (Resoundant Inc.) using 90% (A90) and 95% (A95) confidence masks. Agreement was evaluated using intra-class correlation coefficients (ICC) and Bland-Altman analyses. Classification performance was evaluated using receiver operating characteristic curve (ROC) analyses. RESULTS In 65 patients with mean age of 15.5 ± 3.8 years (range 8-23 years; 35 males) median liver shear stiffness was 2.99 kPa (mean 3.55 ± 1.69 kPa). Inter-reader agreement for manual processing was very strong (ICC = 0.99, mean bias = 0.01 kPa [95% limits of agreement (LoA): - 0.41 to 0.44 kPa]). Correlation between manual and A95 automated processing was very strong (R1: ICC = 0.988, mean bias = 0.13 kPa [95% LoA: - 0.40 to 0.68 kPa]; R2: ICC = 0.987, mean bias = 0.13 kPa [95% LoA: - 0.44 to 0.69 kPa]). Automated measurements were perfectly replicable (ICC = 1.0; mean bias = 0 kPa). CONCLUSION Liver shear stiffness values obtained using automated processing showed excellent agreement with manual processing. Automated processing of liver MRE was perfectly replicable.
Collapse
Affiliation(s)
- Deep B Gandhi
- Department of Radiology, Imaging Research Center (IRC), Cincinnati Children's Hospital Medical Center (CCHMC), Cincinnati, OH, USA
| | - Amol Pednekar
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA.
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
- Imaging Research Center, 3333 Burnet Avenue, Suite S1.533, Cincinnati, OH, 45229, USA.
| | - Adebayo B Braimah
- Department of Radiology, Imaging Research Center (IRC), Cincinnati Children's Hospital Medical Center (CCHMC), Cincinnati, OH, USA
| | - Jonathan Dudley
- Department of Radiology, Imaging Research Center (IRC), Cincinnati Children's Hospital Medical Center (CCHMC), Cincinnati, OH, USA
| | - Jean A Tkach
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Andrew T Trout
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Alexander G Miethke
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA
- Division of Hepatology, Gastroenterology and Nutrition, Cincinnati Children's Hospital Medical Center (CCHMC), Cincinnati, OH, USA
| | - Marnix D Franck
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
- Radboud University, Nijmegen, The Netherlands
| | | | - Bogdan Dzyubak
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - David S Lake
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Jonathan R Dillman
- Department of Radiology, Imaging Research Center (IRC), Cincinnati Children's Hospital Medical Center (CCHMC), Cincinnati, OH, USA
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| |
Collapse
|
18
|
Joshi A, Muthe MM, Firke V, Badgujar H. Preliminary experience with 3T magnetic resonance elastography imaging of the liver. SA J Radiol 2021; 25:2072. [PMID: 34192073 PMCID: PMC8182447 DOI: 10.4102/sajr.v25i1.2072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2020] [Accepted: 03/10/2021] [Indexed: 11/06/2022] Open
Abstract
Background Magnetic resonance elastography (MRE) is a promising non-invasive technique for the identification and quantification of hepatic fibrosis. This manuscript describes our early experience with MRE for the assessment of the presence and staging of liver fibrosis on a 3T magnetic resonance imaging (MRI) system. Objectives The purpose of this study was to describe the MRE physics, procedure, interpretation and drawbacks, along with a few recommendations as per our experience. Method Magnetic resonance elastography was performed on 85 patients with a 3T MRI and the images were analysed both qualitatively and quantitatively. Liver stiffness was assessed by drawing freehand geographic regions of interest on the elastograms to cover the maximum portion of the hepatic parenchyma within the 95% confidence maps on each slice. Correlation with histopathology was performed whenever available. Results Of the 80 patients who met the inclusion criteria, 41 patients displayed a normal liver stiffness measurement (LSM) and 39 patients had a raised LSM. In the patients who had a raised LSM, 14 patients had Stage I–II fibrosis, 8 patients had Stage II–III fibrosis, 6 patients had Stage III–IV fibrosis, 4 patients had Stage IV fibrosis or cirrhosis and 7 patients had non-alcoholic steatohepatitis. The mean thickness of the waves increased with increasing stages of fibrosis. The waves became gradually darker medially in patients with normal LSM as compared to the patients with raised LSM. Histopathology with METAVIR scoring was available in 46 patients, which agreed with the MRE findings in all except two patients. Conclusion Magnetic resonance elastography is a suitable non-invasive modality for the identification and quantification of hepatic fibrosis.
Collapse
Affiliation(s)
- Anagha Joshi
- Department of Radiology, Lokmanya Tilak Municipal Medical College, Lokmanya Tilak Municipal General Hospital, Mumbai, India
| | - Mridula M Muthe
- Department of Radiology, Lokmanya Tilak Municipal Medical College, Lokmanya Tilak Municipal General Hospital, Mumbai, India
| | - Vikrant Firke
- Department of Radiology, Lokmanya Tilak Municipal Medical College, Lokmanya Tilak Municipal General Hospital, Mumbai, India
| | - Harshal Badgujar
- Department of Radiology, Lokmanya Tilak Municipal Medical College, Lokmanya Tilak Municipal General Hospital, Mumbai, India
| |
Collapse
|
19
|
Evaluation of MR elastography for prediction of lymph node metastasis in prostate cancer. Abdom Radiol (NY) 2021; 46:3387-3400. [PMID: 33651125 DOI: 10.1007/s00261-021-02982-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 01/17/2021] [Accepted: 02/09/2021] [Indexed: 12/22/2022]
Abstract
PURPOSE To assess the relationship between MRE stiffness of prostate cancer (PCa) and the extent of lymph node metastasis (LNM) in patients with PCa undergoing radical prostatectomy (RP) and extended pelvic lymph node dissection (ePLND). MATERIALS The local institutional review board approved this retrospective study. We retrospectively analyzed 49 patients, who had undergone MRE, mpMRI and pelvic MRI on a 3.0 T MRI scanner, with histopathological confirmed PCa after RP (from June 2015 to December 2019). For each patient, preoperative clinical data and characteristics of MRE, mpMRI and pelvic MRI were recorded. Independent-samples t test, univariate and multivariate logistic regression analyses were performed. And receiver operating characteristic (ROC) analysis were performed to compare the diagnostic performances of multivariate models with the Briganti 2019 nomogram. RESULTS PCa MRE stiffness and maximum diameter were independent predictors of LNM. When PCa MRE stiffness at 60 Hz (odds ratio [OR] = 20.223, P = 0.013) and maximum diameter (OR = 4.575, P = 0.046) were combined, the sensitivity and specificity were 100% and 91.9% to predict LNM. When PCa MRE stiffness at 90 Hz (OR = 7.920, P = 0.013) and maximum diameter (OR = 2.810, P = 0.045) were combined, the sensitivity and specificity were 100% and 86.5% to predict LNM. The areas under curves (AUCs) of the combinations were higher than the AUC of the Briganti 2019 nomogram (0.982 vs. 0.904, P = 0.040 [60 Hz]; 0.975 vs. 0.904, P = 0.060 [90 Hz], respectively). CONCLUSIONS MRE-based assessment of PCa stiffness may be useful for predicting LNM of PCa preoperatively and noninvasively.
Collapse
|
20
|
Kumada T, Toyoda H, Yasuda S, Sone Y, Ogawa S, Takeshima K, Tada T, Ito T, Sumida Y, Tanaka J. Prediction of Hepatocellular Carcinoma by Liver Stiffness Measurements Using Magnetic Resonance Elastography After Eradicating Hepatitis C Virus. Clin Transl Gastroenterol 2021; 12:e00337. [PMID: 33888672 PMCID: PMC8078363 DOI: 10.14309/ctg.0000000000000337] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Accepted: 03/05/2021] [Indexed: 02/07/2023] Open
Abstract
INTRODUCTION Liver fibrosis stage is one of the most important factors in stratifying the risk of developing hepatocellular carcinoma (HCC). We evaluated the usefulness of liver stiffness measured by magnetic resonance elastography (MRE) to stratify the risk of developing HCC in patients who underwent MRE before receiving direct-acting antivirals (DAAs) and subsequently achieved sustained virological response (SVR). METHODS A total of 537 consecutive patients with persistent hepatitis C virus who underwent initial MRE before DAA therapy and achieved SVR were enrolled. Factors associated with HCC development were analyzed by univariate and multivariate Cox proportional hazards models. RESULTS Albumin-bilirubin score ≥ -2.60 (adjusted hazard ratio [aHR] 6.303), fibrosis-4 (FIB-4) score >3.25 (aHR 7.676), and MRE value ≥4.5 kPa (aHR 13.190) were associated with HCC development according to a univariate Cox proportional hazards model. A multivariate Cox proportional hazards model showed that an MRE value ≥4.5 kPa (aHR 7.301) was the only factor independently associated with HCC development. Even in patients with an FIB-4 score >3.25, the cumulative incidence rate of HCC development in those with an MRE value <4.5 kPa was significantly lower than that in patients with an MRE value ≥4.5 kPa. DISCUSSION Liver stiffness measured by MRE before DAA therapy was an excellent marker for predicting subsequent HCC development in patients with hepatitis C virus infection who achieved SVR. The same results were observed in patients with high FIB-4 scores.
Collapse
Affiliation(s)
- Takashi Kumada
- Department of Nursing, Faculty of Nursing, Gifu Kyoritsu University, Ogaki, Gifu, Japan
| | - Hidenori Toyoda
- Department of Gastroenterology and Hepatology, Ogaki Municipal Hospital, Ogaki, Gifu, Japan
| | - Satoshi Yasuda
- Department of Gastroenterology and Hepatology, Ogaki Municipal Hospital, Ogaki, Gifu, Japan
| | - Yasuhiro Sone
- Department of Radiology, Ogaki Municipal Hospital, Ogaki, Gifu, Japan
| | - Sadanobu Ogawa
- Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Gifu, Japan
| | - Kenji Takeshima
- Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Gifu, Japan
| | - Toshifumi Tada
- Department of Internal Medicine, Himeji Red Cross Hospital, Himeji, Hyougo, Japan
| | - Takanori Ito
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Yoshio Sumida
- Division of Hepatology and Pancreatology, Department of Internal Medicine, Aichi Medical University, Nagakute, Aichi, Japan
| | - Junko Tanaka
- Department of Epidemiology, Infectious Disease Control, and Prevention, Hiroshima University Institute of Biomedical and Health Sciences, Hiroshima, Japan
| |
Collapse
|
21
|
Abstract
Early diagnosis of hepatic fibrosis (HF) is pivotal for management to cease progression to cirrhosis and hepatocellular carcinoma. HF is the telltale sign of chronic liver disease, and confirmed by liver biopsy, which is an invasive technique and inclined to sampling errors. The morphologic parameters of cirrhosis are assessed on conventional imaging such as on ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI). Newer imaging modalities such as magnetic resonance elastography and US elastography are reliable and accurate. More research studies on novel imaging modalities such as MRI with diffusion weighted imaging, enhancement by hepatobiliary contrast agents, and CT using perfusion are essential for earlier diagnosis, surveillance and accurate management. The purpose of this article is to discuss non-invasive CT, MRI, and US imaging modalities for diagnosis and stratify HF.
Collapse
Affiliation(s)
- Mayur Virarkar
- Department of Neuroradiology, The University of Texas Health Science Center, Houston, TX.
| | - Ajaykumar C Morani
- Department of Abdominal Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Melissa W Taggart
- Department of Pathology, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Priya Bhosale
- Department of Abdominal Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX
| |
Collapse
|
22
|
Abstract
A 72-year-old woman with an elevated body mass index and moderate alcohol intake was seen in the gastroenterology clinic. The patient had a past history of abnormal liver function tests and previous biopsy-proven steatosis with early fibrosis. She was reevaluated, following an initial loss to follow-up, by using US elastography to assess for fibrosis progression. The utility of US elastography in the noninvasive diagnosis and longitudinal monitoring of hepatic fibrosis is discussed. An overview of available technologies, including transient elastography and shear-wave elastography, is provided. ©RSNA, 2021 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Aileen O'Shea
- From the Department of Radiology, Division of Abdominal Imaging (A.O.S., T.T.P.), and Center for Ultrasound Research & Translation, Department of Radiology (T.T.P.), Massachusetts General Hospital, 55 Fruit St, Room 217, Boston, MA 02114
| | - Theodore T Pierce
- From the Department of Radiology, Division of Abdominal Imaging (A.O.S., T.T.P.), and Center for Ultrasound Research & Translation, Department of Radiology (T.T.P.), Massachusetts General Hospital, 55 Fruit St, Room 217, Boston, MA 02114
| |
Collapse
|
23
|
Abdominal Stiffness Evaluation in Massage for Constipation. SENSORS 2021; 21:s21041192. [PMID: 33567621 PMCID: PMC7915621 DOI: 10.3390/s21041192] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Revised: 02/04/2021] [Accepted: 02/04/2021] [Indexed: 12/13/2022]
Abstract
According to the experience of nurses and physiotherapists, the abdomen of constipated people becomes softer after abdominal massage. However, the relationship between the decrease in abdominal stiffness and the benefits of abdominal massage has not been examined quantitatively and is unclear. Furthermore, devices for measuring stiffness have been designed to measure relatively hard areas such as the shoulders and do not take into account the lateral outflow of the target tissue, which can be a problem when measuring the stiffness of soft areas such as the abdomen. To address these issues, this study presents a stiffness sensor suitable for measuring abdominal stiffness and investigates the relationship between the reduction in abdominal stiffness and the benefits of abdominal massage. The solution to prevent the lateral outflow of the target is the realization of a stopper, including a contact detection device, which enables a wide-area contact around the targeted area. The sensor consists of a stopper, probe, spring, and time-of-flight (ToF) sensors. The probe and spring provide appropriate pressure and deformation to the abdomen, whereas the stopper prevents the probe from being pushed into the abdomen more than necessary. The ToF sensor measures the deformation length when the deformation is stopped by the stopper. The abdominal stiffness can be derived from the deformation length. The investigation results indicate that the reduction in abdominal stiffness corresponds to the improvement of the stool condition or the maintenance of a healthy stool condition, whereas the maintenance of abdominal stiffness indicates the maintenance or deterioration of the stool condition.
Collapse
|
24
|
Magnetic resonance elastography to quantify liver disease severity in autosomal recessive polycystic kidney disease. Abdom Radiol (NY) 2021; 46:570-580. [PMID: 32757071 DOI: 10.1007/s00261-020-02694-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 05/30/2020] [Accepted: 07/25/2020] [Indexed: 12/11/2022]
Abstract
OBJECTIVES To evaluate whether liver and spleen magnetic resonance elastography (MRE) can measure the severity of congenital hepatic fibrosis (CHF) and portal hypertension (pHTN) in individuals with autosomal recessive polycystic kidney disease (ARPKD), and to examine correlations between liver MRE and ultrasound (US) elastography. METHODS Cross-sectional study of nine individuals with ARPKD and 14 healthy controls. MRE was performed to measure mean liver and spleen stiffness (kPa); US elastography was performed to measure point shear wave speed (SWS) in both liver lobes. We compared: (1) MRE liver and spleen stiffness between controls vs. ARPKD; and (2) MRE liver stiffness between participants with ARPKD without vs. with pHTN, and examined correlations between MRE liver stiffness, spleen length, platelet counts, and US elastography SWS. Receiver operating characteristic (ROC) analysis was performed to examine diagnostic accuracy of liver MRE. RESULTS Participants with ARPKD (median age 16.8 [IQR 13.3, 18.9] years) had higher median MRE liver stiffness than controls (median age 14.7 [IQR 9.7, 16.7 years) (2.55 vs. 1.92 kPa, p = 0.008), but MRE spleen stiffness did not differ. ARPKD participants with pHTN had higher median MRE liver stiffness than those without (3.60 kPa vs 2.49 kPa, p = 0.05). Liver MRE and US elastography measurements were strongly correlated. To distinguish ARPKD vs. control groups, liver MRE had 78% sensitivity and 93% specificity at a proposed cut-off of 2.48 kPa [ROC area 0.83 (95% CI 0.63-1.00)]. CONCLUSION Liver MRE may be a useful quantitative method to measure the severity of CHF and pHTN in individuals with ARPKD.
Collapse
|
25
|
MR Elastography. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00058-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
26
|
Abstract
Application of MRE for noninvasive evaluation of renal fibrosis has great potential for noninvasive assessment in patients with chronic kidney disease (CKD). CKD leads to severe complications, which require dialysis or kidney transplant and could even result in death. CKD in native kidneys and interstitial fibrosis in allograft kidneys are the two major kidney fibrotic pathologies where MRE may be clinically useful. Both these conditions can lead to extensive morbidity, mortality, and high health care costs. Currently, biopsy is the standard method for renal fibrosis staging. This method of diagnosis is painful, invasive, limited by sampling bias, exhibits inter- and intraobserver variability, requires prolonged hospitalization, poses risk of complications and significant bleeding, and could even lead to death. MRE based methods can potentially be useful to noninvasively detect, stage, and monitor renal fibrosis, reducing the need for renal biopsy. In this chapter, we describe experimental procedure and step by step instructions to run MRE along with some illustrative applications. We also includes sections on how to perform data quality check and analysis methods.This publication is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers.
Collapse
Affiliation(s)
- Suraj D Serai
- Department of Radiology, Children's Hospital of Philadelphia, University of Pennsylvania, Philadelphia, PA, USA.
| | - Meng Yin
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
27
|
Plaikner M, Kremser C, Viveiros A, Zoller H, Henninger B. [Magnetic resonance elastography of the liver : Worth knowing for clinical routine]. Radiologe 2020; 60:966-978. [PMID: 32399783 DOI: 10.1007/s00117-020-00690-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND Magnetic resonance elastography (MRE) is a noninvasive, quantitative, MRI-based method to evaluate liver stiffness. Beside biopsy and ultrasound elastography, this imaging method plays in many places a significant role in the detection and additive characterization of chronic liver disease. OBJECTIVES, MATERIALS AND METHODS Based on the literature, a brief review of the underlying method and the commercially available products is given. Furthermore, the practical procedure, the analysis, and the interpretation of clinically relevant questions are illustrated and a comparison with ultrasound elastography is provided. RESULTS This relative "young" MRI method allows extensive evaluation of mechanical properties of the liver and is an important diagnostic tool especially in follow-up examinations. The MRE of the liver is with a maximum technical failure rate of 5.8% a robust technique with high accuracy and an excellent re-test reliability as well as intra- and interobserver reproducibility. There is a high diagnostic certainty within the framework of most important clinical indications, the quantification of fibrosis, and with a very good correlation with the "gold standard" biopsy. CONCLUSION Based on its rising clinical relevance and the broad usage, MRE of the liver is increasingly used in many centers and in routine liver protocols. Therefore, basic knowledge of this method is essential for every radiologist.
Collapse
Affiliation(s)
- Michaela Plaikner
- Radiologie, Medizinische Universität Innsbruck, Anichstraße 35, 6020, Innsbruck, Österreich.
| | - Christian Kremser
- Radiologie, Medizinische Universität Innsbruck, Anichstraße 35, 6020, Innsbruck, Österreich
| | - André Viveiros
- Innere Medizin I, Medizinische Universität Innsbruck, Anichstraße 35, 6020, Innsbruck, Österreich
| | - Heinz Zoller
- Innere Medizin I, Medizinische Universität Innsbruck, Anichstraße 35, 6020, Innsbruck, Österreich
| | - Benjamin Henninger
- Radiologie, Medizinische Universität Innsbruck, Anichstraße 35, 6020, Innsbruck, Österreich
| |
Collapse
|
28
|
Shahryari M, Meyer T, Warmuth C, Herthum H, Bertalan G, Tzschätzsch H, Stencel L, Lukas S, Lilaj L, Braun J, Sack I. Reduction of breathing artifacts in multifrequency magnetic resonance elastography of the abdomen. Magn Reson Med 2020; 85:1962-1973. [PMID: 33104294 DOI: 10.1002/mrm.28558] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 08/21/2020] [Accepted: 09/28/2020] [Indexed: 12/17/2022]
Abstract
PURPOSE With abdominal magnetic resonance elastography (MRE) often suffering from breathing artifacts, it is recommended to perform MRE during breath-hold. However, breath-hold acquisition prohibits extended multifrequency MRE examinations and yields inconsistent results when patients cannot hold their breath. The purpose of this work was to analyze free-breathing strategies in multifrequency MRE of abdominal organs. METHODS Abdominal MRE with 30, 40, 50, and 60 Hz vibration frequencies and single-shot, multislice, full wave-field acquisition was performed four times in 11 healthy volunteers: once with multiple breath-holds and three times during free breathing with ungated, gated, and navigated slice adjustment. Shear wave speed maps were generated by tomoelastography inversion. Image registration was applied for correction of intrascan misregistration of image slices. Sharpness of features was quantified by the variance of the Laplacian. RESULTS Total scan times ranged from 120 seconds for ungated free-breathing MRE to 376 seconds for breath-hold examinations. As expected, free-breathing MRE resulted in larger organ displacements (liver, 4.7 ± 1.5 mm; kidneys, 2.4 ± 2.2 mm; spleen, 3.1 ± 2.4 mm; pancreas, 3.4 ± 1.4 mm) than breath-hold MRE (liver, 0.7 ± 0.2 mm; kidneys, 0.4 ± 0.2 mm; spleen, 0.5 ± 0.2 mm; pancreas, 0.7 ± 0.5 mm). Nonetheless, breathing-related displacement did not affect mean shear wave speed, which was consistent across all protocols (liver, 1.43 ± 0.07 m/s; kidneys, 2.35 ± 0.21 m/s; spleen, 2.02 ± 0.15 m/s; pancreas, 1.39 ± 0.15 m/s). Image registration before inversion improved the quality of free-breathing examinations, yielding no differences in image sharpness to uncorrected breath-hold MRE in most organs (P > .05). CONCLUSION Overall, multifrequency MRE is robust to breathing when considering whole-organ values. Respiration-related blurring can readily be corrected using image registration. Consequently, ungated free-breathing MRE combined with image registration is recommended for multifrequency MRE of abdominal organs.
Collapse
Affiliation(s)
- Mehrgan Shahryari
- Department of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Tom Meyer
- Department of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Carsten Warmuth
- Department of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Helge Herthum
- Department of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Gergely Bertalan
- Department of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Heiko Tzschätzsch
- Department of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Lisa Stencel
- Department of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Steffen Lukas
- Department of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Ledia Lilaj
- Department of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Jürgen Braun
- Institute of Medical Informatics, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Ingolf Sack
- Department of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
29
|
Cruz M, Ferreira AA, Papanikolaou N, Banerjee R, Alves FC. New boundaries of liver imaging: from morphology to function. Eur J Intern Med 2020; 79:12-22. [PMID: 32571581 DOI: 10.1016/j.ejim.2020.06.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 05/20/2020] [Accepted: 06/04/2020] [Indexed: 12/12/2022]
Abstract
From an invisible organ to one of the most explored non-invasively, the liver is, today, one of the cornerstones for current cross-sectional imaging techniques and minimally invasive procedures. After the achievements of US, CT and, most recently, MRI in providing highly accurate morphological and structural information about the organ, a significant scientific development has gained momentum for the last decades, coupling morphology to liver function and contributing far most to what we know today as precision medicine. In fact, dedicated tailor-made investigations are now possible in order to detect and, most of all, quantify physiopathological processes with unprecedented certitude. It is the intention of this review to provide a better insight to the reader of several functional imaging techniques applied to liver imaging. Contrast enhanced imaging, diffusion weighted imaging, elastography, spectral computed tomography and fat and iron assessment techniques are commonly performed clinically. Diffusion kurtosis imaging, magnetic resonance spectroscopy, T1 relaxometry and radiomics remain largely limited to advanced clinical research. Each of them has its own value and place on the diagnostic armamentarium and provide unique qualitative and quantitative information regarding the pathophysiology of diseases, contributing at a large scale to model therapeutic decisions and patient follow-up. Therefore, state-of-the-art liver imaging acts today as a non-invasive surrogate biomarker of many focal and diffuse liver diseases.
Collapse
Affiliation(s)
- Manuel Cruz
- Department of Radiology, Faculty of Medicine, University Hospital Coimbra and CIBIT/ICNAS research center, University of Coimbra, Coimbra, Portugal.
| | - Ana Aguiar Ferreira
- Department of Radiology, Faculty of Medicine, University Hospital Coimbra and CIBIT/ICNAS research center, University of Coimbra, Coimbra, Portugal
| | - Nikolaos Papanikolaou
- Computational Clinical Imaging Group, Centre for the Unknown, Champalimaud Foundation, Lisbon, Portugal
| | - Rajarshi Banerjee
- Department of Acute Medicine, Oxford University Hospitals NHS Trust, Oxford, United Kingdom
| | - Filipe Caseiro Alves
- Department of Radiology, Faculty of Medicine, University Hospital Coimbra and CIBIT/ICNAS research center, University of Coimbra, Coimbra, Portugal
| |
Collapse
|
30
|
Uterine leiomyomas: correlation between histologic composition and stiffness via magnetic resonance elastography - a Pilot Study. Ginekol Pol 2020; 91:373-378. [PMID: 32542642 DOI: 10.5603/gp.a2020.0067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Revised: 03/11/2020] [Accepted: 03/13/2020] [Indexed: 11/25/2022] Open
Abstract
OBJECTIVES To evaluate magnetic resonance elastography as a tool for characterizing uterine leimyomas. MATERIAL AND METHODS At total of 12 women with symptomatic leiomyomas diagnosed in physical and ultrasound examinations were enrolled in this pilot study. Before surgery, all patients underwent magnetic resonance elastography of the uterus using a 1.5 T MR whole-body scanner (Optima, GE Healthcare, Milwaukee, WI, USA). Surgical specimens were forwarded for histological examination. The findings were allocated into 3 categories depending on the percentage content of connective tissue: below 15%, from 15 to 30% and more than 30%. The median stiffness of leiomyomas for each of the group was calculated. The U-Mann Whitney test was used for statistical analysis. RESULTS The stiffness of the leiomyomas ranged between 3.7-6.9 kPa (median value 4.9 kPa). The concentration of extracellular components in the leiomyomas did not exceed 40%. An increasing trend of the stiffness with the growing percentage of extracellular component was observed. Stiffness of the leiomyomas obtained by MRE varies depending on microscopic composition. CONCLUSIONS The value of stiffness shows a trend of increasing with the percentage of extracellular component of the leiomyoma. Further studies are required to assess the usefulness of MRE in diagnostics of uterine leiomyomas.
Collapse
|
31
|
Wang XP, Wang Y, Ma H, Wang H, Yang DW, Zhao XY, Jin EH, Yang ZH. Assessment of liver fibrosis with liver and spleen magnetic resonance elastography, serum markers in chronic liver disease. Quant Imaging Med Surg 2020; 10:1208-1222. [PMID: 32550131 DOI: 10.21037/qims-19-849] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Background The accurate assessment of liver fibrosis is essential for patients with chronic liver disease. A liver biopsy is an invasive procedure that has many potential defects and complications. Therefore, noninvasive assessment techniques are of considerable value for clinical diagnosis. Liver and spleen magnetic resonance elastography (MRE) and serum markers have been proposed for quantitative and noninvasive assessment of liver fibrosis. This study aims to compare the diagnostic performance of liver and spleen stiffness measured by MRE, fibrosis index based on the 4 factors (FIB-4), aspartate aminotransferase-to-platelet ratio index (APRI), and their combined models for staging hepatic fibrosis. Methods One hundred and twenty patients with chronic liver disease underwent MRE scans. Liver and spleen stiffness were measured by the MRE stiffness maps. Serum markers were collected to calculate FIB-4 and APRI. Liver biopsies were used to identify pathologic grading. Spearman's rank correlation analysis evaluated the correlation between the parameters and fibrosis stages. Receiver operating characteristic (ROC) analysis evaluated the performance of the four individual parameters, a liver and spleen stiffness combined model, and an all-parameters combined model in assessing liver fibrosis. Results Liver stiffness, spleen stiffness, FIB-4, and APRI were all correlated with fibrosis stage (r=0.87, 0.64, 0.65, and 0.51, respectively, all P<0.001). Among the 4 individual diagnostic markers, liver stiffness showed the highest values in staging F1-4, F2-4, F3-4 and F4 (AUC =0.89, 0. 97, 0.95, and 0.95, all P<0.001). The AUCs of the liver and spleen stiffness combined model in the F1-4, F2-4, F3-4, and F4 staging groups were 0.89, 0.97, 0.95, and 0.96, respectively (all P<0.001). The corresponding AUCs of the all-parameters combined model were 0.90, 0.97, 0.95, and 0.96 (all P<0.001). The AUCs of the liver and spleen stiffness combined model were significantly higher than those of APRI, FIB-4 in the F2-4, F3-4, and F4 staging groups (all P<0.05). Both combined models were not significantly different from liver stiffness in staging liver fibrosis (all P>0.05). Conclusions Liver stiffness measured with MRE had better diagnostic performance than spleen stiffness, APRI, and FIB-4 for fibrosis staging. The combined models did not significantly improve the diagnostic value compared with liver stiffness in staging fibrosis.
Collapse
Affiliation(s)
- Xiao-Pei Wang
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Yu Wang
- Liver Research Center, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Hong Ma
- Liver Research Center, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Han Wang
- Liver Research Center, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Da-Wei Yang
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Xin-Yan Zhao
- Liver Research Center, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Er-Hu Jin
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Zheng-Han Yang
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| |
Collapse
|
32
|
Han JH, Ahn JH, Kim JS. Magnetic resonance elastography for evaluation of renal parenchyma in chronic kidney disease: a pilot study. Radiol Med 2020; 125:1209-1215. [DOI: 10.1007/s11547-020-01210-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Accepted: 04/20/2020] [Indexed: 12/22/2022]
|
33
|
Kim HJ, Kim B, Yu HJ, Huh J, Lee JH, Lee SS, Kim KW, Kim JK. Reproducibility of hepatic MR elastography across field strengths, pulse sequences, scan intervals, and readers. Abdom Radiol (NY) 2020; 45:107-115. [PMID: 31720766 DOI: 10.1007/s00261-019-02312-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
PURPOSE To evaluate the reproducibility of hepatic MRE under various combinations of settings of field strength, pulse sequence, scan interval, and reader in non-alcoholic fatty liver disease (NAFLD) patients. METHODS Adult NAFLD patients were prospectively enrolled for serial hepatic MRE with 1.5 T using 2D GRE sequence and 3.0 T using 2D SE-EPI sequence on the same day and after 2 weeks, resulting a total of four MRE examinations per patient. Three readers with various levels of background knowledge in MRE technique and liver anatomy measured liver stiffness after a training session. Linear regression, Bland-Altman analysis, within-subject coefficient of variation, and reproducibility coefficient (RDC) were used to determine reproducibility of hepatic MRE measurement. RESULTS Twenty patients completed the MRE sessions. Liver stiffness through MRE showed pooled RDC of 26% (upper 95% CI 30.6%) and corresponding limits of agreement (LOA) within 0.55 kPa across field strengths, MRE sequences, and 2-week interscan interval in three readers. Small mean biases and narrow LOA were observed among readers (0.05-0.19 kPa ± 0.53). CONCLUSION The magnitude of change across combinations of scan parameters is within acceptable clinical range, rendering liver stiffness through MRE a reproducible quantitative imaging biomarker. A lower reproducibility was observed for measurements under different field strengths/MRE sequences at a longer (2 weeks) interscan interval. Operators should be trained to acquire region of interest consistently in repeat examinations.
Collapse
Affiliation(s)
- Hye Jin Kim
- Department of Radiology, Ajou University School of Medicine, Ajou University Hospital, 164 World cup-ro, Yeongtong-gu, Suwon, 16499, South Korea
| | - Bohyun Kim
- Department of Radiology, Ajou University School of Medicine, Ajou University Hospital, 164 World cup-ro, Yeongtong-gu, Suwon, 16499, South Korea.
| | - Hyun Jeong Yu
- Department of Radiology, Ajou University School of Medicine, Ajou University Hospital, 164 World cup-ro, Yeongtong-gu, Suwon, 16499, South Korea
| | - Jimi Huh
- Department of Radiology, Ajou University School of Medicine, Ajou University Hospital, 164 World cup-ro, Yeongtong-gu, Suwon, 16499, South Korea
| | - Jei Hee Lee
- Department of Radiology, Ajou University School of Medicine, Ajou University Hospital, 164 World cup-ro, Yeongtong-gu, Suwon, 16499, South Korea
| | - Seung Soo Lee
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
| | - Kyung Won Kim
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
| | - Jai Keun Kim
- Department of Radiology, Ajou University School of Medicine, Ajou University Hospital, 164 World cup-ro, Yeongtong-gu, Suwon, 16499, South Korea
| |
Collapse
|
34
|
Goyal NP, Sawh MC, Ugalde-Nicalo P, Angeles JE, Proudfoot JA, Newton KP, Middleton MS, Sirlin CB, Schwimmer JB. Evaluation of Quantitative Imaging Biomarkers for Early-phase Clinical Trials of Steatohepatitis in Adolescents. J Pediatr Gastroenterol Nutr 2020; 70:99-105. [PMID: 31633654 PMCID: PMC8053386 DOI: 10.1097/mpg.0000000000002535] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
OBJECTIVES Early-phase pediatric nonalcoholic fatty liver disease (NAFLD) clinical trials are designed with noninvasive parameters to assess potential efficacy. Increasingly, these parameters include magnetic resonance imaging (MRI)-derived proton density fat fraction (PDFF) and MR elastography (MRE)-derived shear stiffness as biomarkers of hepatic steatosis and fibrosis, respectively. Understanding fluctuations in these measures is essential for calculating trial sample sizes, interpreting results, and planning clinical drug trials in children with NAFLD. Lack of such data in children constitutes a critical knowledge gap. Therefore, the primary aim of this study was to assess whole-liver MRI-PDFF change in adolescents with nonalcoholic steatohepatitis (NASH) over 12 weeks. METHODS Adolescents 12 to 19 years with biopsy-proven NASH undergoing standard-of-care treatment were enrolled. Baseline and week-12 assessments of anthropometrics, transaminases, MRI-PDFF, and MRE stiffness were obtained. RESULTS Fifteen adolescents were included (mean age 15.7 [SD 2.9] years). Hepatic MRI-PDFF was stable over 12 weeks (mean absolute change -0.8%, P = 0.24). Correlation between baseline and week-12 values of MRI-PDFF was high (ICC = 0.97, 95% CI 0.90-0.99). MRE stiffness was stable (mean percentage change 2.7%, P = 0.44); correlation between baseline and week-12 values was moderate (ICC = 0.47; 95% CI 0-0.79). Changes in weight, BMI, and aminotransferases were not statistically significant. CONCLUSION In adolescents with NASH, fluctuations in hepatic MRI-PDFF and MRE stiffness over 12 weeks of standard-of-care were small. These data on the natural fluctuations in quantitative imaging biomarkers can serve as a reference for interventional trials in pediatric NASH and inform the interpretation and planning of clinical trials.
Collapse
Affiliation(s)
- Nidhi P. Goyal
- Division of Gastroenterology, Hepatology, and Nutrition, Department of Pediatrics, University of California, San Diego School of Medicine, San Diego, California
- Department of Gastroenterology, Rady Children's Hospital San Diego, San Diego, California
| | - Mary Catherine Sawh
- Division of Gastroenterology, Hepatology, and Nutrition, Department of Pediatrics, University of California, San Diego School of Medicine, San Diego, California
- Department of Gastroenterology, Rady Children's Hospital San Diego, San Diego, California
| | - Patricia Ugalde-Nicalo
- Division of Gastroenterology, Hepatology, and Nutrition, Department of Pediatrics, University of California, San Diego School of Medicine, San Diego, California
| | - Jorge E. Angeles
- Division of Gastroenterology, Hepatology, and Nutrition, Department of Pediatrics, University of California, San Diego School of Medicine, San Diego, California
| | - James A. Proudfoot
- Clinical and Translational Research Institute, University of California, San Diego
| | - Kimberly P. Newton
- Division of Gastroenterology, Hepatology, and Nutrition, Department of Pediatrics, University of California, San Diego School of Medicine, San Diego, California
- Department of Gastroenterology, Rady Children's Hospital San Diego, San Diego, California
| | - Michael S. Middleton
- Liver Imaging Group, Department of Radiology, University of California, San Diego School of Medicine, San Diego, California
| | - Claude B. Sirlin
- Liver Imaging Group, Department of Radiology, University of California, San Diego School of Medicine, San Diego, California
| | - Jeffrey B. Schwimmer
- Division of Gastroenterology, Hepatology, and Nutrition, Department of Pediatrics, University of California, San Diego School of Medicine, San Diego, California
- Department of Gastroenterology, Rady Children's Hospital San Diego, San Diego, California
| |
Collapse
|
35
|
Guglielmo FF, Venkatesh SK, Mitchell DG. Liver MR Elastography Technique and Image Interpretation: Pearls and Pitfalls. Radiographics 2019; 39:1983-2002. [DOI: 10.1148/rg.2019190034] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Flavius F. Guglielmo
- From the Department of Radiology, Thomas Jefferson University Hospital, 132 S 10th St, Philadelphia, PA 19107 (F.F.G., D.G.M.); and Department of Radiology, Mayo Clinic, Rochester, Minn (S.K.V.)
| | - Sudhakar K. Venkatesh
- From the Department of Radiology, Thomas Jefferson University Hospital, 132 S 10th St, Philadelphia, PA 19107 (F.F.G., D.G.M.); and Department of Radiology, Mayo Clinic, Rochester, Minn (S.K.V.)
| | - Donald G. Mitchell
- From the Department of Radiology, Thomas Jefferson University Hospital, 132 S 10th St, Philadelphia, PA 19107 (F.F.G., D.G.M.); and Department of Radiology, Mayo Clinic, Rochester, Minn (S.K.V.)
| |
Collapse
|
36
|
Chen YJ, Yamazoe T, Leavens KF, Cardenas-Diaz FL, Georgescu A, Huh D, Gadue P, Stanger BZ. iPreP is a three-dimensional nanofibrillar cellulose hydrogel platform for long-term ex vivo preservation of human islets. JCI Insight 2019; 4:124644. [PMID: 31672937 DOI: 10.1172/jci.insight.124644] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Accepted: 09/20/2019] [Indexed: 01/12/2023] Open
Abstract
Islet transplantation is an effective therapy for achieving and maintaining normoglycemia in patients with type 1 diabetes mellitus. However, the supply of transplantable human islets is limited. Upon removal from the pancreas, islets rapidly disintegrate and lose function, resulting in a short interval for studies of islet biology and pretransplantation assessment. Here, we developed a biomimetic platform that can sustain human islet physiology for a prolonged period ex vivo. Our approach involved the creation of a multichannel perifusion system to monitor dynamic insulin secretion and intracellular calcium flux simultaneously, enabling the systematic evaluation of glucose-stimulated insulin secretion under multiple conditions. Using this tool, we developed a nanofibrillar cellulose hydrogel-based islet-preserving platform (iPreP) that can preserve islet viability, morphology, and function for nearly 12 weeks ex vivo, and with the ability to ameliorate glucose levels upon transplantation into diabetic hosts. Our platform has potential applications in the prolonged maintenance of human islets, providing an expanded time window for pretransplantation assessment and islet studies.
Collapse
Affiliation(s)
- Yi-Ju Chen
- Gastroenterology Division, Department of Medicine.,Department of Cell and Developmental Biology, and.,Abramson Family Cancer Research Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.,Genetic Resource Science, The Jackson Laboratory, Bar Harbor, Maine, USA
| | | | - Karla F Leavens
- Center for Cellular and Molecular Therapeutics, Department of Pathology and Laboratory Medicine.,Division of Endocrinology, Department of Pediatrics, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | - Fabian L Cardenas-Diaz
- Center for Cellular and Molecular Therapeutics, Department of Pathology and Laboratory Medicine
| | - Andrei Georgescu
- Department of Bioengineering, School of Engineering and Applied Sciences, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Dongeun Huh
- Department of Bioengineering, School of Engineering and Applied Sciences, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Paul Gadue
- Center for Cellular and Molecular Therapeutics, Department of Pathology and Laboratory Medicine
| | - Ben Z Stanger
- Gastroenterology Division, Department of Medicine.,Department of Cell and Developmental Biology, and.,Abramson Family Cancer Research Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
37
|
Lefebvre T, Petitclerc L, Hébert M, Bilodeau L, Sebastiani G, Olivié D, Gao ZH, Sylvestre MP, Cloutier G, Nguyen BN, Gilbert G, Tang A. MRI cine-tagging of cardiac-induced motion for noninvasive staging of liver fibrosis. J Magn Reson Imaging 2019; 51:1570-1580. [PMID: 31605412 DOI: 10.1002/jmri.26935] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2019] [Accepted: 09/05/2019] [Indexed: 01/17/2023] Open
Abstract
BACKGROUND MR elastography is a noninvasive technique that provides high diagnostic accuracy for the staging of liver fibrosis; however, it requires external hardware and mainly assesses the right lobe. PURPOSE To evaluate the diagnostic performance of MRI cine-tagging for staging fibrosis in the left liver lobe, using biopsy as the reference standard. STUDY TYPE Institutional Review Board (IRB)-approved two-center prospective study. POPULATION Seventy-six patients with chronic liver disease who underwent an MRI cine-tagging examination and a liver biopsy within a 6-week interval. FIELD STRENGTH/SEQUENCE 2D-GRE multislice sequence at 3.0T with spatial modulation of the magnetization preparation sequence and peripheral pulse-wave triggering on two coronal slices chosen underneath the heart apex to capture maximal deformation with consecutive breath-holds adapted to patient cardiac frequency. ASSESSMENT A region of interest was selected in the liver close to the heart apex. Maximal strain was evaluated with the harmonic phase (HARP) technique. STATISTICAL TESTS Spearman's correlation, Kruskal-Wallis test, Mann-Whitney U-test, and receiver operating characteristic (ROC) analysis were performed. RESULTS Liver strain measured on tagged images decreased with higher histological fibrosis stage (ρ = -0.68, P < 0.0001). Strain values were significantly different between all fibrosis stages (P < 0.0001), and between groups of fibrosis stages ≤F3 vs. F4 (P < 0.05). Areas under the ROC curves were 0.95 (95% confidence interval: 0.89-1.00) to distinguish fibrosis stages F0 vs. F4, 0.81 (0.70-0.92) for stages F0 vs. ≥F1, 0.84 (0.76-0.93) for stages ≤F1 vs. ≥F2, 0.86 (0.78-0.94) for stages ≤F2 vs. ≥F3, and 0.87 (0.77-0.96) for stages ≤F3 vs. F4. DATA CONCLUSION MRI cine-tagging is a promising technique for measuring liver strain without additional elastography hardware. It could be used to assess the left liver lobe as a complement to current techniques assessing the right lobe. LEVEL OF EVIDENCE 1 Technical Efficacy: 3 J. Magn. Reson. Imaging 2020;51:1570-1580.
Collapse
Affiliation(s)
- Thierry Lefebvre
- Department of Radiology, Radio-Oncology and Nuclear Medicine, Université de Montréal, Montréal, Québec, Canada.,Centre de recherche du Centre hospitalier de l'Université de Montréal (CRCHUM), Montréal, Québec, Canada.,Medical Physics Unit, McGill University, Montréal, Québec, Canada
| | - Léonie Petitclerc
- Department of Radiology, Radio-Oncology and Nuclear Medicine, Université de Montréal, Montréal, Québec, Canada.,Centre de recherche du Centre hospitalier de l'Université de Montréal (CRCHUM), Montréal, Québec, Canada.,C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center (LUMC), Leiden, The Netherlands
| | - Mélanie Hébert
- Department of Radiology, Radio-Oncology and Nuclear Medicine, Université de Montréal, Montréal, Québec, Canada.,Centre de recherche du Centre hospitalier de l'Université de Montréal (CRCHUM), Montréal, Québec, Canada
| | - Laurent Bilodeau
- Department of Radiology, Radio-Oncology and Nuclear Medicine, Université de Montréal, Montréal, Québec, Canada.,Centre de recherche du Centre hospitalier de l'Université de Montréal (CRCHUM), Montréal, Québec, Canada
| | - Giada Sebastiani
- Department of Medicine, Division of Gastroenterology and Hepatology, McGill University Health Centre (MUHC), Montréal, Québec, Canada
| | - Damien Olivié
- Department of Radiology, Radio-Oncology and Nuclear Medicine, Université de Montréal, Montréal, Québec, Canada
| | - Zu-Hua Gao
- Department of Pathology, McGill University, Montréal, Québec, Canada
| | - Marie-Pierre Sylvestre
- Centre de recherche du Centre hospitalier de l'Université de Montréal (CRCHUM), Montréal, Québec, Canada.,Department of Social and Preventive Medicine, École de santé publique de l'Université de Montréal (ESPUM), Montréal, Québec, Canada
| | - Guy Cloutier
- Department of Radiology, Radio-Oncology and Nuclear Medicine, Université de Montréal, Montréal, Québec, Canada.,Institute of Biomedical Engineering, Université de Montréal, Montréal, Québec, Canada.,Laboratory of Biorheology and Medical Ultrasonics (LBUM), Centre de recherche du Centre hospitalier de l'Université de Montréal (CRCHUM), Montréal, Québec, Canada
| | - Bich N Nguyen
- Service of Pathology, Centre hospitalier de l'Université de Montréal (CHUM), Montréal, Québec, Canada
| | - Guillaume Gilbert
- Department of Radiology, Radio-Oncology and Nuclear Medicine, Université de Montréal, Montréal, Québec, Canada.,MR Clinical Science, Philips Healthcare Canada, Montréal, Québec, Canada
| | - An Tang
- Department of Radiology, Radio-Oncology and Nuclear Medicine, Université de Montréal, Montréal, Québec, Canada.,Centre de recherche du Centre hospitalier de l'Université de Montréal (CRCHUM), Montréal, Québec, Canada.,Institute of Biomedical Engineering, Université de Montréal, Montréal, Québec, Canada
| |
Collapse
|
38
|
Lang ST, Guo J, Bruns A, Dürr M, Braun J, Hamm B, Sack I, Marticorena Garcia SR. Multiparametric Quantitative MRI for the Detection of IgA Nephropathy Using Tomoelastography, DWI, and BOLD Imaging. Invest Radiol 2019; 54:669-674. [DOI: 10.1097/rli.0000000000000585] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
39
|
Sawh MC, Newton KP, Goyal NP, Angeles JE, Harlow K, Bross C, Schlein AN, Hooker JC, Sy EZ, Glaser KJ, Yin M, Ehman RL, Sirlin CB, Schwimmer JB. Normal range for MR elastography measured liver stiffness in children without liver disease. J Magn Reson Imaging 2019; 51:919-927. [PMID: 31452280 DOI: 10.1002/jmri.26905] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Accepted: 08/05/2019] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Magnetic resonance elastography (MRE) can determine the presence and stage of liver fibrosis. Data on normative MRE values, while reported in adults, are limited in children. PURPOSE To determine the distribution of MRE-measured liver stiffness in children without liver disease. STUDY TYPE Prospective, observational. POPULATION Eighty-one healthy children (mean 12.6 ± 2.6 years, range 8-17 years). FIELD STRENGTH/SEQUENCE 3.0T Signa HDxt, General Electric MR Scanner; 2D GRE MRE sequence. ASSESSMENT History, examination, laboratory evaluation, and (MR) exams (proton density fat fraction, PDFF, and MRE) were performed. MR elastograms were analyzed manually at two reading centers and compared with each other for agreement and with published values in healthy adults and thresholds for fibrosis in adult and pediatric patients. STATISTICAL TESTS Descriptive statistics, Bland-Altman analysis, t-test to compare hepatic stiffness values with reference standards. RESULTS Stiffness values obtained at both reading centers were similar, without significant bias (P = 0.362) and with excellent correlation (intraclass correlation coefficient [ICC] = 0.782). Mean hepatic stiffness value for the study population was 2.45 ± 0.35 kPa (95th percentile 3.19 kPa), which was significantly higher than reported values for healthy adult subjects (2.10 ± 0.23 kPa, P < 0.001). In all, 74-85% of subjects had stiffness measurements suggestive of no fibrosis. DATA CONCLUSION Mean liver stiffness measured with MRE in this cohort was significantly higher than that reported in healthy adults. Despite rigorous screening, some healthy children had stiffness measurements suggestive of liver fibrosis using current published thresholds. Although MRE has the potential to provide noninvasive assessment in patients with suspected hepatic disease, further refinement of this technology will help advance its use as a diagnostic tool for evidence of fibrosis in pediatric populations. LEVEL OF EVIDENCE 1 Technical Efficacy: 5 J. Magn. Reson. Imaging 2020;51:919-927.
Collapse
Affiliation(s)
- Mary Catherine Sawh
- The Department of Pediatrics, Division of Gastroenterology, Hepatology, and Nutrition, University of California San Diego School of Medicine, La Jolla, California, USA.,Department of Gastroenterology, Rady Children's Hospital, San Diego, California, USA
| | - Kimberly P Newton
- The Department of Pediatrics, Division of Gastroenterology, Hepatology, and Nutrition, University of California San Diego School of Medicine, La Jolla, California, USA.,Department of Gastroenterology, Rady Children's Hospital, San Diego, California, USA
| | - Nidhi P Goyal
- The Department of Pediatrics, Division of Gastroenterology, Hepatology, and Nutrition, University of California San Diego School of Medicine, La Jolla, California, USA.,Department of Gastroenterology, Rady Children's Hospital, San Diego, California, USA
| | - Jorge Eduardo Angeles
- The Department of Pediatrics, Division of Gastroenterology, Hepatology, and Nutrition, University of California San Diego School of Medicine, La Jolla, California, USA
| | - Kathryn Harlow
- The Department of Pediatrics, Division of Gastroenterology, Hepatology, and Nutrition, University of California San Diego School of Medicine, La Jolla, California, USA.,Department of Gastroenterology, Rady Children's Hospital, San Diego, California, USA
| | - Craig Bross
- The Department of Pediatrics, Division of Gastroenterology, Hepatology, and Nutrition, University of California San Diego School of Medicine, La Jolla, California, USA
| | - Alexandra N Schlein
- Liver Imaging Group, Department of Radiology, University of California San Diego School of Medicine, La Jolla, California, USA
| | - Jonathan C Hooker
- Liver Imaging Group, Department of Radiology, University of California San Diego School of Medicine, La Jolla, California, USA
| | - Ethan Z Sy
- Liver Imaging Group, Department of Radiology, University of California San Diego School of Medicine, La Jolla, California, USA
| | - Kevin J Glaser
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Meng Yin
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Richard L Ehman
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Claude B Sirlin
- Liver Imaging Group, Department of Radiology, University of California San Diego School of Medicine, La Jolla, California, USA
| | - Jeffrey B Schwimmer
- The Department of Pediatrics, Division of Gastroenterology, Hepatology, and Nutrition, University of California San Diego School of Medicine, La Jolla, California, USA.,Department of Gastroenterology, Rady Children's Hospital, San Diego, California, USA
| |
Collapse
|
40
|
Assessment of liver fibrosis with gadoxetic acid-enhanced MRI: comparisons with transient elastography, ElastPQ, and serologic fibrosis markers. Abdom Radiol (NY) 2019; 44:2769-2780. [PMID: 31041497 DOI: 10.1007/s00261-019-02041-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECTIVES To compare the diagnostic performance of gadoxetic acid-enhanced magnetic resonance imaging (MRI), ultrasonography (US)-based elastography, and serologic fibrosis markers in assessing the stage of liver fibrosis. MATERIALS AND METHODS This retrospective study included 67 patients (55 male and 12 female; mean age 62.5 years) who underwent gadoxetic acid-enhanced MRI and liver stiffness measurements before liver biopsy or surgery between January 2014 and January 2018. Measurements were performed using transient elastography (TE), ultrasound shear wave elastography point quantification (ElastPQ), and blood tests. The following MRI-based fibrosis markers were assessed: contrast enhancement index (CEI), liver-spleen contrast ratio (LSC), liver-portal vein contrast ratio (LPC), and signal intensity ratio (SIR). The diagnostic performances of fibrosis markers were compared using the area under the receiver operating characteristic curve (AUC), with histopathologic fibrosis stage as the reference standard. RESULTS The fibrosis stages were F0-F1 (n = 17), F2 (n = 7), F3 (n = 20), and F4 (n = 23). MRI-based fibrosis markers negatively correlated with histologic stage: CEI (r = -0.786); LSC (r = - 0.718); LPC (r = - 0.448); and SIR (r = - 0.617; all P < 0.001). For diagnosis of either significant liver fibrosis (≥ F2) or cirrhosis (F4), the CEI provided better diagnostic accuracy (AUC = 0.898 and 0.881) than the aspartate aminotransferase-to-platelet ratio index (APRI) (AUC = 0.699 and 0.715; all P < 0.05). The CEI displayed similar diagnostic accuracy for ≥ F2 or F4 when using TE (AUC = 0.866 and 0.884, both P > 0.05) or ElastPQ [AUC = 0.751 (P = 0.021) and AUC = 0.786 (P = 0.234)]. CONCLUSIONS The CEI measured by gadoxetic acid-enhanced MRI allows the staging of liver fibrosis, with a diagnostic accuracy comparable to that of TE and superior to that of ElastPQ or APRI.
Collapse
|
41
|
Abstract
OBJECTIVE. The purpose of this article is to discuss quantitative methods of CT, MRI, and ultrasound (US) for noninvasive staging of hepatic fibrosis. Hepatic fibrosis is the hallmark of chronic liver disease (CLD), and staging by random liver biopsy is invasive and prone to sampling errors and subjectivity. Several noninvasive quantitative imaging methods are under development or in clinical use. The accuracy, precision, technical aspects, advantages, and disadvantages of each method are discussed. CONCLUSION. The most promising methods are the liver surface nodularity score using CT and measurement of liver stiffness using MR elastography or US elastography.
Collapse
|
42
|
Jiang K, Ferguson CM, Lerman LO. Noninvasive assessment of renal fibrosis by magnetic resonance imaging and ultrasound techniques. Transl Res 2019; 209:105-120. [PMID: 31082371 PMCID: PMC6553637 DOI: 10.1016/j.trsl.2019.02.009] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2018] [Revised: 02/12/2019] [Accepted: 02/20/2019] [Indexed: 02/06/2023]
Abstract
Renal fibrosis is a useful biomarker for diagnosis and guidance of therapeutic interventions of chronic kidney disease (CKD), a worldwide disease that affects more than 10% of the population and is one of the major causes of death. Currently, tissue biopsy is the gold standard for assessment of renal fibrosis. However, it is invasive, and prone to sampling error and observer variability, and may also result in complications. Recent advances in diagnostic imaging techniques, including magnetic resonance imaging (MRI) and ultrasonography, have shown promise for noninvasive assessment of renal fibrosis. These imaging techniques measure renal fibrosis by evaluating its impacts on the functional, mechanical, and molecular properties of the kidney, such as water mobility by diffusion MRI, tissue hypoxia by blood oxygenation level dependent MRI, renal stiffness by MR and ultrasound elastography, and macromolecule content by magnetization transfer imaging. Other MR techniques, such as T1/T2 mapping and susceptibility-weighted imaging have also been explored for measuring renal fibrosis. Promising findings have been reported in both preclinical and clinical studies using these techniques. Nevertheless, limited specificity, sensitivity, and practicality in these techniques may hinder their immediate application in clinical routine. In this review, we will introduce methodologies of these techniques, outline their applications in fibrosis imaging, and discuss their limitations and pitfalls.
Collapse
Affiliation(s)
- Kai Jiang
- Division of Nephrology and Hypertension, Mayo Clinic, Rochester, Minnesota
| | | | - Lilach O Lerman
- Division of Nephrology and Hypertension, Mayo Clinic, Rochester, Minnesota.
| |
Collapse
|
43
|
Obrzut M, Atamaniuk V, Obrzut B, Ehman R, Cholewa M, Rzucidło M, Pozaruk A, Gutkowski K. Normative values for magnetic resonance elastography-based liver stiffness in a healthy population. Pol Arch Intern Med 2019; 129:321-326. [PMID: 30793705 PMCID: PMC6731548 DOI: 10.20452/pamw.4456] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
INTRODUCTION Chronic liver disease resulting in fibrosis, and ultimately cirrhosis, is a significant cause of morbidity and mortality worldwide. None of the conventional imaging techniques are able to detect early fibrosis and compare its grade with the histopathologic scale. Liver biopsy, as the diagnostic standard for liver fibrosis, also has limitations and is not well accepted by patients. Magnetic resonance elastography is a well‑established technique for evaluating liver stiffness and may replace invasive procedures. Detection of liver fibrosis in its early stages, however, requires a detailed knowledge of normal liver stiffness. OBJECTIVES This study aimed to determine normal liver stiffness values in healthy volunteers. PATIENTS AND METHODS A total of 102 volunteers (mean age, 21.6 years; range, 20-28 years) with no history of gastrointestinal, hepatobiliary, or cardiovascular disease were enrolled in the study. Liver stiffness was evaluated by magnetic resonance elastography with a 1.5T clinical magnetic resonance scanner. Images of the induced transverse wave propagation were obtained and converted to tissue stiffness maps (elastograms). RESULTS The mean (SD) liver stiffness for the entire group of volunteers was 2.14 (0.28) kPa (range, 1.37-2.66 kPa). For women, the mean (SD) stiffness value was 2.14 (0.30) kPa (range, 1.37-2.66 kPa), and for men, 2.14 (0.25) kPa (range, 1.54-2.54 kPa). CONCLUSIONS Liver stiffness in a healthy adult cohort did not exceed 2.7 kPa and is not influenced by sex, body mass index, or fat content.
Collapse
Affiliation(s)
- Marzanna Obrzut
- Department of Biophysics, Faculty of Mathematics and Natural Sciences, University of Rzeszów, Rzeszów, Poland
| | - Vitaliy Atamaniuk
- Department of Biophysics, Faculty of Mathematics and Natural Sciences, University of Rzeszów, Rzeszów, Poland
| | - Bogdan Obrzut
- Department of Obstetrics and Gynaecology, Provincial Clinical Hospital No 2 in Rzeszow, University of Rzeszów, Rzeszów, Poland
| | - Richard Ehman
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, United States
| | - Marian Cholewa
- Department of Biophysics, Faculty of Mathematics and Natural Sciences, University of Rzeszów, Rzeszów, Poland
| | - Mateusz Rzucidło
- Department of Gastroenterology and Hepatology with Internal Disease Unit, Teaching Hospital No. 1 in Rzeszów, Rzeszów, Poland
| | - Andrii Pozaruk
- Department of Biophysics, Faculty of Mathematics and Natural Sciences, University of Rzeszów, Rzeszów, Poland,Monash Biomedical Imaging, Monash University, Melbourne, Australia
| | - Krzysztof Gutkowski
- Department of Gastroenterology and Hepatology with Internal Disease Unit, Teaching Hospital No. 1 in Rzeszów, Rzeszów, Poland
| |
Collapse
|
44
|
Akkaya HE, Erden A, Kuru Öz D, Ünal S, Erden İ. Magnetic resonance elastography: basic principles, technique, and clinical applications in the liver. ACTA ACUST UNITED AC 2019; 24:328-335. [PMID: 30272563 DOI: 10.5152/dir.2018.18186] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Magnetic resonance elastography (MRE) is a constantly advancing technique for assessment of stiffness of tissues with newer technology and sequences. It is being increasingly used for the assessment of liver fibrosis. In this article, we discuss the advantages of MRE over biopsy and noninvasive methods such as US elastography in the assessment of liver fibrosis. Image acquisition and interpretation of liver MRE is also discussed.
Collapse
Affiliation(s)
| | - Ayşe Erden
- Department of Radiology, Ankara University School of Medicine, Ankara, Turkey
| | - Diğdem Kuru Öz
- Department of Radiology, Ankara University School of Medicine, Ankara, Turkey
| | - Sena Ünal
- Department of Radiology, Erzurum Local Training and Research Hospital, Erzurum, Turkey
| | - İlhan Erden
- Department of Radiology, Ankara University School of Medicine, Ankara, Turkey
| |
Collapse
|
45
|
Plaikner M, Kremser C, Zoller H, Steurer M, Glodny B, Jaschke W, Henninger B. Does gadoxetate disodium affect MRE measurements in the delayed hepatobiliary phase? Eur Radiol 2019; 29:829-837. [PMID: 30027410 PMCID: PMC6302879 DOI: 10.1007/s00330-018-5616-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Revised: 05/24/2018] [Accepted: 06/18/2018] [Indexed: 02/07/2023]
Abstract
OBJECTIVES To assess if the administration of gadoxetate disodium (Gd-EOB-DTPA) significantly affects hepatic magnetic resonance elastography (MRE) measurements in the delayed hepatobiliary phase (DHBP). METHODS A total of 47 patients (15 females, 32 males; age range 23-78 years, mean 54.28 years) were assigned to standard hepatic magnetic resonance imaging (MRI) with application of Gd-EOB-DTPA and hepatic MRE. MRE was performed before injection of Gd-EOB-DTPA and after 40-50 min in the DHBP. Liver stiffness values were obtained before and after contrast media application and differences between pre- and post-Gd-EOB-DTPA values were evaluated using a Bland-Altman plot and the Mann-Whitney-Wilcoxon test. In addition, the data were compared with regard to the resulting fibrosis classification. RESULTS Mean hepatic stiffness for pre-Gd-EOB-DTPA measurements was 4.01 kPa and post-Gd-EOB-DTPA measurements yielded 3.95 kPa. We found a highly significant individual correlation between pre- and post-Gd-EOB-DTPA stiffness values (Pearson correlation coefficient of r = 0.95 (p < 0.001) with no significant difference between the two measurements (p =0.49)). Bland-Altman plot did not show a systematic effect for the difference between pre- and post-stiffness measurements (mean difference: 0.06 kPa, SD 0.81). Regarding the classification of fibrosis stages, the overall agreement was 87.23% and the intraclass correlation coefficient was 96.4%, indicating excellent agreement. CONCLUSIONS Administration of Gd-EOB-DTPA does not significantly influence MRE stiffness measurements of the liver in the DHBP. Therefore, MRE can be performed in the DHBP. KEY POINTS • MRE of the liver can reliably be performed in the delayed hepatobiliary phase. • Gd-EOB-DTPA does not significantly influence MRE stiffness measurements of the liver. • MRE performed in the delayed hepatobiliary-phase is reasonable in patients with reduced liver function.
Collapse
Affiliation(s)
- M Plaikner
- Department of Radiology, Medical University of Innsbruck, Anichstraße 35, Innsbruck, Austria
| | - C Kremser
- Department of Radiology, Medical University of Innsbruck, Anichstraße 35, Innsbruck, Austria
| | - H Zoller
- Department of Internal Medicine, Medical University of Innsbruck, Anichstraße 35, Innsbruck, Austria
| | - M Steurer
- Department of Radiology, Medical University of Innsbruck, Anichstraße 35, Innsbruck, Austria
| | - B Glodny
- Department of Radiology, Medical University of Innsbruck, Anichstraße 35, Innsbruck, Austria
| | - W Jaschke
- Department of Radiology, Medical University of Innsbruck, Anichstraße 35, Innsbruck, Austria
| | - B Henninger
- Department of Radiology, Medical University of Innsbruck, Anichstraße 35, Innsbruck, Austria.
| |
Collapse
|
46
|
Tomoelastography Paired With T2* Magnetic Resonance Imaging Detects Lupus Nephritis With Normal Renal Function. Invest Radiol 2019; 54:89-97. [DOI: 10.1097/rli.0000000000000511] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
47
|
Paternostro R, Reiberger T, Bucsics T. Elastography-based screening for esophageal varices in patients with advanced chronic liver disease. World J Gastroenterol 2019; 25:308-329. [PMID: 30686900 PMCID: PMC6343095 DOI: 10.3748/wjg.v25.i3.308] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Revised: 11/27/2018] [Accepted: 12/20/2018] [Indexed: 02/06/2023] Open
Abstract
Elastography-based liver stiffness measurement (LSM) is a non-invasive tool for estimating liver fibrosis but also provides an estimate for the severity of portal hypertension in patients with advanced chronic liver disease (ACLD). The presence of varices and especially of varices needing treatment (VNT) indicates distinct prognostic stages in patients with compensated ACLD (cACLD). The Baveno VI guidelines suggested a simple algorithm based on LSM < 20 kPa (by transient elastography, TE) and platelet count > 150 G/L for ruling-out VNT in patients with cACLD. These (and other) TE-based LSM cut-offs have been evaluated for VNT screening in different liver disease etiologies. Novel point shear-wave elastography (pSWE) and two-dimensional shear wave elastography (2D-SWE) methodologies for LSM have also been evaluated for their ability to screen for “any” varices and for VNT. Finally, the measurement of spleen stiffness (SSM) by elastography (mainly by pSWE and 2D-SWE) may represent another valuable screening tool for varices. Here, we summarize the current literature on elastography-based prediction of “any” varices and VNT. Finally, we have summarized the published LSM and SSM cut-offs in clinically useful scale cards.
Collapse
Affiliation(s)
- Rafael Paternostro
- Department of Medicine III, Division of Gastroenterology and Hepatology, Medical University of Vienna, Vienna A-1090, Austria
| | - Thomas Reiberger
- Department of Medicine III, Division of Gastroenterology and Hepatology, Medical University of Vienna, Vienna A-1090, Austria
| | - Theresa Bucsics
- Department of Medicine III, Division of Gastroenterology and Hepatology, Medical University of Vienna, Vienna A-1090, Austria
| |
Collapse
|
48
|
New and Emerging Applications of Magnetic Resonance Elastography of Other Abdominal Organs. Top Magn Reson Imaging 2019; 27:335-352. [PMID: 30289829 DOI: 10.1097/rmr.0000000000000182] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Increasing clinical experience and ongoing research in the field of magnetic resonance elastography (MRE) is leading to exploration of its applications in other abdominal organs. In this review, the current research progress of MRE in prostate, uterus, pancreas, spleen, and kidney will be discussed. The article will describe patient preparation, modified technical approach including development of passive drivers, modification of sequences, and inversion. The potential clinical application of MRE in the evaluation of several disease processes affecting these organs will be discussed. In an era of increasing adoption of multiparametric magnetic resonance imaging approaches for solving complex abdominal problems, abdominal MRE as a biomarker may be seamlessly incorporated into a standard magnetic resonance imaging examination to provide a rapid, reliable, and comprehensive imaging evaluation at a single patient appointment in the future.
Collapse
|
49
|
Abstract
The first clinical application of magnetic resonance elastography (MRE) was in the evaluation of chronic liver disease (CLD) for detection and staging of liver fibrosis. In the past 10 years, MRE has been incorporated seamlessly into a standard magnetic resonance imaging (MRI) liver protocol worldwide. Liver MRE is a robust technique for evaluation of liver stiffness and is currently the most accurate noninvasive imaging technology for evaluation of liver fibrosis. Newer MRE sequences including spin-echo MRE and 3 dimensional MRE have helped in reducing the technical limitations of clinical liver MRE that is performed with 2D gradient recalled echo (GRE) MRE. Advances in MRE technology have led to understanding of newer mechanical parameters such as dispersion, attenuation, and viscoelasticity that may be useful in evaluating pathological processes in CLD and may prove useful in their management.This review article will describe the changes in CLD that cause an increase in stiffness followed by principle and technique of liver MRE. In the later part of the review, we will briefly discuss the advances in liver MRE.
Collapse
|
50
|
Neumann W, Bichert A, Fleischhauer J, Stern A, Figuli R, Wilhelm M, Schad LR, Zöllner FG. A novel 3D printed mechanical actuator using centrifugal force for magnetic resonance elastography: Initial results in an anthropomorphic prostate phantom. PLoS One 2018; 13:e0205442. [PMID: 30296308 PMCID: PMC6175527 DOI: 10.1371/journal.pone.0205442] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Accepted: 09/25/2018] [Indexed: 12/12/2022] Open
Abstract
This work demonstrates a new method for the generation of mechanical shear wave during magnetic resonance elastography (MRE) that creates greater forces at higher vibrational frequencies as opposed to conventionally used pneumatic transducers. We developed an MR-compatible pneumatic turbine with an eccentric mass that creates a sinusoidal centrifugal force. The turbine was assessed with respect to its technical parameters and evaluated for MRE on a custom-made anthropomorphic prostate phantom. The silicone-based tissue-mimicking materials of the phantom were selected with regard to their complex shear moduli examined by rheometric testing. The tissue-mimicking materials closely matched human soft tissue elasticity values with a complex shear modulus ranging from 3.21 kPa to 7.29 kPa. We acquired MRE images on this phantom at 3 T with actuation frequencies of 50, 60 Hz, 70 Hz, and 80 Hz. The turbine generated vibrational wave amplitudes sufficiently large to entirely penetrate the phantoms during the feasibility study. Increased wave length in the stiffer inclusions compared to softer background material were detected. Our initial results suggest that silicone-based phantoms are useful for the evaluation of elasticities during MRE. Furthermore, our turbine seems suitable for the mechanical assessment of soft tissue during MRE.
Collapse
Affiliation(s)
- Wiebke Neumann
- Department of Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Andreas Bichert
- Department of Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Jonas Fleischhauer
- Department of Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Antonia Stern
- Department of Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Roxana Figuli
- Institute for Chemical Technology and Polymer Chemistry of Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Manfred Wilhelm
- Institute for Chemical Technology and Polymer Chemistry of Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Lothar R. Schad
- Department of Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Frank G. Zöllner
- Department of Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| |
Collapse
|