1
|
Stoll S, Hwang JH, Fox DW, Kim K, Zhai L, Lee WH. Cost-effective screen-printed carbon electrode biosensors for rapid detection of microcystin-LR in surface waters for early warning of harmful algal blooms. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:124854-124865. [PMID: 36194320 DOI: 10.1007/s11356-022-23300-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Accepted: 09/23/2022] [Indexed: 06/16/2023]
Abstract
Microcystins (MCs) are toxins produced by cyanobacteria commonly found in harmful algal blooms (HABs). Due to their toxicity to humans and other organisms, the World Health Organization (WHO) sets a guideline of 1 μg L-1 for microcystin-leucine-arginine (MC-LR) in drinking water. However, current analytical techniques for the detection of MC-LR such as liquid chromatography-mass spectrometry (LC-MS) and ELISA are costly, bulky, time-consuming, and mostly conducted in a laboratory, requiring highly trained personnel. An analytical method that can be used in the field for rapid determination is essential. In this study, an anti-MC-LR/MC-LR/cysteamine-coated screen-printed carbon electrode (SPCE) biosensor was newly developed to detect MC-LR, bioelectrochemically, in water. The functionalization of the electrode surface was confirmed with surface characterization methods. The sensor performance was evaluated by electrochemical impedance spectroscopy (EIS), obtaining a linear working range of MC-LR concentrations between 0.1 and 100 μg L-1 with a limit of detection (LOD) of 0.69 ng L-1. Natural water samples experiencing HABs were collected and analyzed using the developed biosensor, demonstrating the excellent performance of the biosensor with a relative standard deviation (RSD) of 0.65%. The interference tests showed minimal error and RSD values against other common MCs and possible coexisting ions found in water. The biosensor showed acceptable functionality with a shelf life of up to 12 weeks. Overall, the anti-MC-LR/MC-LR/cysteamine/SPCE biosensors can be an innovative solution with characteristics that allow for in situ, low-cost, and easy-to-use capabilities which are essential for developing an overarching and integrated "smart" environmental management system.
Collapse
Affiliation(s)
- Stephanie Stoll
- Department of Civil, Environmental, and Construction Engineering, University of Central Florida, Orlando, FL, 32816, USA
| | - Jae-Hoon Hwang
- Department of Civil, Environmental, and Construction Engineering, University of Central Florida, Orlando, FL, 32816, USA
| | - David W Fox
- Nanoscience Technology Center and Department of Chemistry, University of Central Florida, Orlando, FL, 32816, USA
| | - Keugtae Kim
- Department of Environmental and Energy Engineering, The University of Suwon, 17 Wauan-gil, Bongdam-eup, Hwaseong-si, Gyeonggi-do, 18323, South Korea
| | - Lei Zhai
- Nanoscience Technology Center and Department of Chemistry, University of Central Florida, Orlando, FL, 32816, USA
| | - Woo Hyoung Lee
- Department of Civil, Environmental, and Construction Engineering, University of Central Florida, Orlando, FL, 32816, USA.
| |
Collapse
|
2
|
Park JA, Kwon Y, Le XA, Vu TH, Park H, Lee H, Choi HK, Park C, Kim MI, Lee T. Construction of a rapid electrochemical biosensor consisting of a nanozyme/aptamer conjugate for waterborne microcystin detection. Analyst 2023; 148:2536-2543. [PMID: 37144330 DOI: 10.1039/d3an00391d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Microcystin-LR (MC-LR) is a hepatotoxin generated by the excessive proliferation of cyanobacteria, which is a threat to humans and wildlife. Therefore, rapid detection of MC-LR is an important challenge. This study describes a rapid electrochemical biosensor comprising nanozymes and aptamers. Alternating current electrothermal flow (ACEF) significantly reduced the MC-LR detection period to 10 min. We also used MnO2/MC-LR aptamer conjugates to improve the sensitivity to MC-LR detection. Here, MnO2 amplified the electrochemical signal and the aptamer showed high selectivity for MC-LR. Under the optimal conditions, the limit of detection (LOD) and selectivity in freshwater were detected using cyclic voltammetry and differential pulse voltammetry. As a result, an LOD of 3.36 pg mL-1 was observed in the linear concentration range of 10 pg mL-1 to 1 μg mL-1. This study quickly and sensitively detected MC-LR in a situation where it causes serious damage worldwide. In addition, the ACEF technology introduction is the first example of MC-LR detection, suggesting a wide range of possibilities for MC-LR biosensors.
Collapse
Affiliation(s)
- Jeong Ah Park
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Republic of Korea.
| | - Yein Kwon
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Republic of Korea.
| | - Xuan Ai Le
- Department of BioNano Technology, Gachon University, 1342 Seongnamdae-ro, Sujeong-gu, Seongnam, Gyeonggi 13120, Republic of Korea.
| | - Trung Hieu Vu
- Department of BioNano Technology, Gachon University, 1342 Seongnamdae-ro, Sujeong-gu, Seongnam, Gyeonggi 13120, Republic of Korea.
| | - Hanbin Park
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Republic of Korea.
| | - Hoseok Lee
- Department of Electrical and Computer Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, Republic of Korea
| | - Hye Kyu Choi
- Department of Chemical and Biomolecular Engineering, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul 121-742, Republic of Korea
| | - Chulhwan Park
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Republic of Korea.
| | - Moon Il Kim
- Department of BioNano Technology, Gachon University, 1342 Seongnamdae-ro, Sujeong-gu, Seongnam, Gyeonggi 13120, Republic of Korea.
| | - Taek Lee
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Republic of Korea.
| |
Collapse
|
3
|
Wei X, Wang S, Zhan Y, Kai T, Ding P. Sensitive Identification of Microcystin-LR via a Reagent-Free and Reusable Electrochemical Biosensor Using a Methylene Blue-Labeled Aptamer. BIOSENSORS 2022; 12:bios12080556. [PMID: 35892453 PMCID: PMC9332554 DOI: 10.3390/bios12080556] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 07/18/2022] [Accepted: 07/21/2022] [Indexed: 05/02/2023]
Abstract
We report a methylene blue (MB)-modified electrochemical aptamer (E-AB) sensor for determining microcystin-LR (MC-LR). The signal transduction of the sensor was based on changes in conformation and position of MB induced by the binding between MC-LR and the modified aptamer probe. In the absence of MC-LR, an aptamer probe was considered partially folded. After combining aptamer and MC-LR, the configuration of the aptamer probe changed and facilitated the electron transfer between MB and the electrode surface. As a result, an increased current response was observed. We optimized the parameters and evaluated the electrochemical performance of the sensor using square wave voltammetry (SWV). MC-LR was measured from 1.0 to 750.0 ng/L with a detection limit of 0.53 ng/L. The reliability of the method was verified by the determination of MC-LR in environmental real samples, such as pond water and tap water. Moreover, we demonstrated that this reagent-less biosensor could be regenerated and reused after rinsing with deionized water with good accuracy and reproducibility. As a reusable and regenerable E-AB sensor, this rapid, reagent-free, and sensitive sensing platform will facilitate routine monitoring of MC-LR in actual samples.
Collapse
Affiliation(s)
- Xiaoqian Wei
- Xiang Ya School of Public Health, Central South University, Changsha 410078, China; (X.W.); (S.W.); (Y.Z.)
- Hunan Provincial Key Laboratory of Clinical Epidemiology, Changsha 410078, China
| | - Shanlin Wang
- Xiang Ya School of Public Health, Central South University, Changsha 410078, China; (X.W.); (S.W.); (Y.Z.)
- Hunan Provincial Key Laboratory of Clinical Epidemiology, Changsha 410078, China
| | - Yujuan Zhan
- Xiang Ya School of Public Health, Central South University, Changsha 410078, China; (X.W.); (S.W.); (Y.Z.)
- Hunan Provincial Key Laboratory of Clinical Epidemiology, Changsha 410078, China
| | - Tianhan Kai
- Xiang Ya School of Public Health, Central South University, Changsha 410078, China; (X.W.); (S.W.); (Y.Z.)
- Hunan Provincial Key Laboratory of Clinical Epidemiology, Changsha 410078, China
- Correspondence: (T.K.); (P.D.)
| | - Ping Ding
- Xiang Ya School of Public Health, Central South University, Changsha 410078, China; (X.W.); (S.W.); (Y.Z.)
- Hunan Provincial Key Laboratory of Clinical Epidemiology, Changsha 410078, China
- Correspondence: (T.K.); (P.D.)
| |
Collapse
|
4
|
Kordasht HK, Hassanpour S, Baradaran B, Nosrati R, Hashemzaei M, Mokhtarzadeh A, la Guardia MD. Biosensing of microcystins in water samples; recent advances. Biosens Bioelectron 2020; 165:112403. [PMID: 32729523 DOI: 10.1016/j.bios.2020.112403] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Revised: 06/16/2020] [Accepted: 06/19/2020] [Indexed: 02/07/2023]
Abstract
Safety and quality of water are significant matters for agriculture, animals and human health. Microcystins, as secondary metabolite of cyanobacteria (blue-green algae) and cyclic heptapeptide cyanotoxin, are one of the main marine toxins in continental aquatic ecosystems. More than 100 microcystins have been identified, of which MC-LR is the most important type due to its high toxicity and common detection in the environment. Climate change is an impressive factor with effects on cyanobacterial blooms as source of microcystins. The presence of this cyanotoxin in freshwater, drinking water, water reservoir supplies and food (vegetable, fish and shellfish) has created a common phenomenon in eutrophic freshwater ecosystems worldwide. International public health organizations have categorized microcystins as a kind of neurotoxin and carcinogen. There are several conventional methods for detection of microcystins. The limitations of traditional methods have encouraged the development of innovative methods for detection of microcystins. In recent years, the developed sensor techniques, with advantages, such as accuracy, reproducibility, portability and low cost, have attracted considerable attention. This review compares the well-known of biosensor types for detection of microcystins with a summary of their analytical performance.
Collapse
Affiliation(s)
- Houman Kholafazad Kordasht
- Department of Food Hygiene and Aquatic, Faculty of Veterinary Medicine, University of Tabriz, Tabriz, Iran
| | - Soodabeh Hassanpour
- Department of Analytical Chemistry, Faculty of Science, Palacky University Olomouc, 17. Listopadu 12, 77146, Olomouc, Czech Republic
| | - Behzad Baradaran
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Rahim Nosrati
- Department of Pharmaceutical Biotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran; Cellular and Molecular Research Center, School of Medicine, Guilan University of Medical Sciences, Rasht, Iran
| | - Mahmoud Hashemzaei
- Department of Pharmacodynamics and Toxicology, School of Pharmacy, Zabol University of Medical Sciences, Zabol, Iran
| | - Ahad Mokhtarzadeh
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| | - Miguel de la Guardia
- Department of Analytical Chemistry, University of Valencia, Dr. Moliner 50, 46100, Burjassot, Valencia, Spain.
| |
Collapse
|
5
|
Vogiazi V, de la Cruz A, Mishra S, Shanov V, Heineman WR, Dionysiou DD. A Comprehensive Review: Development of Electrochemical Biosensors for Detection of Cyanotoxins in Freshwater. ACS Sens 2019; 4:1151-1173. [PMID: 31056912 PMCID: PMC6625642 DOI: 10.1021/acssensors.9b00376] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Cyanobacteria harmful algal blooms are increasing in frequency and cyanotoxins have become an environmental and public concern in the U.S. and worldwide. In this Review, the majority of reported studies and developments of electrochemical affinity biosensors for cyanotoxins are critically reviewed and discussed. Essential background information about cyanobacterial toxins and electrochemical biosensors is combined with the rapidly moving development of electrochemical biosensors for these toxins. Current issues and future challenges for the development of useful electrochemical biosensors for cyanotoxin detection that meet the demands for applications in field freshwater samples are discussed. The major aspects of the entire review article in a prescribed sequence include (i) the state-of-the-art knowledge of the toxicity of cyanotoxins, (ii) important harmful algal bloom events, (iii) advisories, guidelines, and regulations, (iv) conventional analytical methods for determination of cyanotoxins, (v) electrochemical transduction, (vi) recognition receptors, (vii) reported electrochemical biosensors for cyanotoxins, (viii) summary of analytical performance, and (ix) recent advances and future trends. Discussion includes electrochemical techniques and devices, biomolecules with high affinity, numerous array designs, various detection approaches, and research strategies in tailoring the properties of the transducer-biomolecule interface. Scientific and engineering aspects are presented in depth. This review aims to serve as a valuable source to scientists and engineers entering the interdisciplinary field of electrochemical biosensors for detection of cyanotoxins in freshwaters.
Collapse
Affiliation(s)
- Vasileia Vogiazi
- Environmental Engineering and Science Program, Department of Chemical and Environmental Engineering (ChEE) , University of Cincinnati , Cincinnati , Ohio 45221 , United States
| | - Armah de la Cruz
- Office of Research and Development , US Environmental Protection Agency , Cincinnati , Ohio 45220 , United States
| | - Siddharth Mishra
- Mechanical and Materials Engineering , University of Cincinnati , Cincinnati 45221 , Ohio United States
| | - Vesselin Shanov
- Environmental Engineering and Science Program, Department of Chemical and Environmental Engineering (ChEE) , University of Cincinnati , Cincinnati , Ohio 45221 , United States
- Mechanical and Materials Engineering , University of Cincinnati , Cincinnati 45221 , Ohio United States
| | - William R Heineman
- Department of Chemistry , University of Cincinnati , Cincinnati , Ohio 45221 , United States
| | - Dionysios D Dionysiou
- Environmental Engineering and Science Program, Department of Chemical and Environmental Engineering (ChEE) , University of Cincinnati , Cincinnati , Ohio 45221 , United States
| |
Collapse
|
6
|
Zhang K, Dai K, Bai R, Ma Y, Deng Y, Li D, Zhang X, Hu R, Yang Y. A competitive microcystin-LR immunosensor based on Au NPs@metal-organic framework (MIL-101). CHINESE CHEM LETT 2019. [DOI: 10.1016/j.cclet.2018.10.021] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
7
|
Goud KY, Kailasa SK, Kumar V, Tsang YF, Lee SE, Gobi KV, Kim KH. Progress on nanostructured electrochemical sensors and their recognition elements for detection of mycotoxins: A review. Biosens Bioelectron 2018; 121:205-222. [PMID: 30219721 DOI: 10.1016/j.bios.2018.08.029] [Citation(s) in RCA: 112] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2018] [Revised: 08/11/2018] [Accepted: 08/13/2018] [Indexed: 12/31/2022]
Abstract
Nanomaterial-embedded sensors have been developed and applied to monitor various targets. Mycotoxins are fungal secondary metabolites that can exert carcinogenic, mutagenic, teratogenic, immunotoxic, and estrogenic effects on humans and animals. Consequently, the need for the proper regulation on foodstuff and feed materials has been recognized from times long past. This review provides an overview of recent developments in electrochemical sensors and biosensors employed for the detection of mycotoxins. Basic aspects of the toxicity of mycotoxins and the implications of their detection are comprehensively discussed. Furthermore, the development of different molecular recognition elements and nanomaterials required for the detection of mycotoxins (such as portable biosensing systems for point-of-care analysis) is described. The current capabilities, limitations, and future challenges in mycotoxin detection and analysis are also addressed.
Collapse
Affiliation(s)
- K Yugender Goud
- Department of Civil and Environmental Engineering, Hanyang University, Seoul 04763, Republic of Korea; Department of Chemistry, National Institute of Technology Warangal, Telangana 506004, India
| | - Suresh Kumar Kailasa
- Department of Applied Chemistry, S. V. National Institute of Technology, Surat 395007, Gujarat, India.
| | - Vanish Kumar
- Department of Applied Sciences, U.I.E.T., Panjab University, Chandigarh 160014, India
| | - Yiu Fai Tsang
- Department of Science and Environmental Studies, The Education University of Hong Kong, Tai Po, New Territories, Hong Kong, China
| | - S E Lee
- School of Applied Biosciences, Kyungpook National University, Daegu 41566, Republic of Korea
| | | | - Ki-Hyun Kim
- Department of Civil and Environmental Engineering, Hanyang University, Seoul 04763, Republic of Korea.
| |
Collapse
|
8
|
Zhang W, Dixon MB, Saint C, Teng KS, Furumai H. Electrochemical Biosensing of Algal Toxins in Water: The Current State-of-the-Art. ACS Sens 2018; 3:1233-1245. [PMID: 29974739 DOI: 10.1021/acssensors.8b00359] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Due to increasing stringency of water legislation and extreme consequences that failure to detect some contaminants in water can involve, there has been a strong interest in developing electrochemical biosensors for algal toxin detection during the past decade, evidenced by literature increasing from 2 journal papers pre-2009 to 24 between 2009 and 2018. In this context, this review has summarized recent progress of successful algal toxin detection in water using electrochemical biosensing techniques. Satisfactory detection recoveries using real environmental water samples and good sensor repeatability and reproducibility have been achieved, along with some excellent limit-of-detection (LOD) reported. Recent electrochemical biosensor literature in algal toxin detection is compared and discussed to cover three major design components: (1) biorecognition elements, (2) electrochemical read-out techniques, and (3) sensor electrodes and signal amplification strategy. The recent development of electrochemical biosensors has provided one more step further toward quick in situ detection of algal toxins in the contamination point of the water source. In the end, we have also critically reviewed the current challenges and research opportunities regarding electrochemical biosensors for algal toxin detection that need to be addressed before they attain commercial viability.
Collapse
Affiliation(s)
- Wei Zhang
- Research Centre for Water Environment Technology, Department of Urban Engineering, The University of Tokyo, Tokyo 113-0033, Japan
- School of Natural and Built Environments, University of South Australia, Mawson Lakes, South Australia 5095, Australia
- College of Engineering, Swansea University, Bay Campus, Swansea, Wales SA1 8EN, United Kingdom
| | | | - Christopher Saint
- School of Natural and Built Environments, University of South Australia, Mawson Lakes, South Australia 5095, Australia
| | - Kar Seng Teng
- College of Engineering, Swansea University, Bay Campus, Swansea, Wales SA1 8EN, United Kingdom
| | - Hiroaki Furumai
- Research Centre for Water Environment Technology, Department of Urban Engineering, The University of Tokyo, Tokyo 113-0033, Japan
| |
Collapse
|
9
|
Talamini L, Zanato N, Zapp E, Brondani D, Vieira IC. Direct Electrochemical Nano-immunosensor for Microcystin-LR in Seawater. ELECTROANAL 2018. [DOI: 10.1002/elan.201700815] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Lucas Talamini
- Department of Chemistry; Federal University of Santa Catarina, Campus Florianópolis; 88040-900 Florianópolis, SC Brazil
| | - Nicole Zanato
- Department of Chemistry; Federal University of Santa Catarina, Campus Florianópolis; 88040-900 Florianópolis, SC Brazil
| | - Eduardo Zapp
- Department of Exact Science and Education; Federal University of Santa Catarina, Campus Blumenau; 89036-256 Blumenau, SC Brazil
| | - Daniela Brondani
- Department of Exact Science and Education; Federal University of Santa Catarina, Campus Blumenau; 89036-256 Blumenau, SC Brazil
| | - Iolanda Cruz Vieira
- Department of Chemistry; Federal University of Santa Catarina, Campus Florianópolis; 88040-900 Florianópolis, SC Brazil
| |
Collapse
|
10
|
Dual-functional Fe3O4@SiO2@Ag triple core-shell microparticles as an effective SERS platform for adipokines detection. Colloids Surf A Physicochem Eng Asp 2017. [DOI: 10.1016/j.colsurfa.2017.09.025] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
11
|
Lebogang L, Jantra J, Hedström M, Mattiasson B. Electrochemical Flow-ELISA for Rapid and Sensitive Determination of Microcystin-LR Using Automated Sequential Injection System. SENSORS 2017; 17:s17071639. [PMID: 28714899 PMCID: PMC5539796 DOI: 10.3390/s17071639] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Revised: 06/30/2017] [Accepted: 07/05/2017] [Indexed: 11/16/2022]
Abstract
An amperometric immunoanalysis system based on monoclonal antibodies immobilized on Sepharose beads and packed into a micro-immunocolumn was developed for the quantification of microcystin-LR. Microcystin-LR (MCLR) was used as a reference microcystin variant. Inside the immunocolumn, free microcystins and microcystin-horseradish peroxidase (tracer) were sequentially captured by the immobilized antibodies, and the detection was performed electrochemically using Super AquaBlue ELISA substrate 2,2'-azinobis(3-ethylbenzothiazoline-sulfonic acid) (ABTS). The ABTS●+ generated by enzymatic oxidation of ABTS was electrochemically determined at a carbon working electrode by applying a reduction potential set at 0.4 V versus Ag/AgCl reference electrode. The peak current intensity was inversely proportional to the amount of analyte bound to the immunocolumn. The amperometric flow-ELISA system, which was automatically controlled through the CapSenzeTM (Lund, Sweden) computer software, enabled determination of MCLR as low as 0.01 µg/L. The assay time was very short (20 min for one assay cycle). In addition, the electrochemical signals were not significantly affected by possible interferences which could be present in the real samples. Along with the simplicity of automation, this makes the developed method a promising tool for use in water quality assessment.
Collapse
Affiliation(s)
- Lesedi Lebogang
- Department of Biotechnology, Lund University, Box 124, SE-22100 Lund, Sweden.
- Department of Biological Sciences and Biotechnology, Botswana International University of Science and Technology, Private Bag 16, Plot 10071, Palapye, Botswana.
| | - Jongjit Jantra
- Department of Biotechnology, Lund University, Box 124, SE-22100 Lund, Sweden.
- CapSenze Biosystems AB, Scheelevägen 22, SE-22363 Lund, Sweden.
| | - Martin Hedström
- Department of Biotechnology, Lund University, Box 124, SE-22100 Lund, Sweden.
- CapSenze Biosystems AB, Scheelevägen 22, SE-22363 Lund, Sweden.
| | - Bo Mattiasson
- Department of Biotechnology, Lund University, Box 124, SE-22100 Lund, Sweden.
- CapSenze Biosystems AB, Scheelevägen 22, SE-22363 Lund, Sweden.
| |
Collapse
|
12
|
Using fluorescence immunochromatographic test strips based on quantum dots for the rapid and sensitive determination of microcystin-LR. Anal Bioanal Chem 2017; 409:2213-2220. [DOI: 10.1007/s00216-016-0166-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2016] [Revised: 11/28/2016] [Accepted: 12/19/2016] [Indexed: 01/03/2023]
|
13
|
D’Souza AA, Kumari D, Banerjee R. Nanocomposite biosensors for point-of-care—evaluation of food quality and safety. NANOBIOSENSORS 2017. [PMCID: PMC7149521 DOI: 10.1016/b978-0-12-804301-1.00015-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Nanosensors have wide applications in the food industry. Nanosensors based on quantum dots for heavy metal and organophosphate pesticides detection, and nanocomposites as indicators for shelf life of fish/meat products, have served as important tools for food quality and safety assessment. Luminescent labels consisting of NPs conjugated to aptamers have been popular for rapid detection of infectious and foodborne pathogens. Various detection technologies, including microelectromechanical systems for gas analytes, microarrays for genetically modified foods, and label-free nanosensors using nanowires, microcantilevers, and resonators are being applied extensively in the food industry. An interesting aspect of nanosensors has also been in the development of the electronic nose and electronic tongue for assessing organoleptic qualities, such as, odor and taste of food products. Real-time monitoring of food products for rapid screening, counterfeiting, and tracking has boosted ingenious, intelligent, and innovative packaging of food products. This chapter will give an overview of the contribution of nanotechnology-based biosensors in the food industry, ongoing research, technology advancements, regulatory guidelines, future challenges, and industrial outlook.
Collapse
|
14
|
Bilibana MP, Williams AR, Rassie C, Sunday CE, Makelane H, Wilson L, Ntshongontshi N, Jijana AN, Masikini M, Baker PGL, Iwuoha EI. Electrochemical Aptatoxisensor Responses on Nanocomposites Containing Electro-Deposited Silver Nanoparticles on Poly(Propyleneimine) Dendrimer for the Detection of Microcystin-LR in Freshwater. SENSORS (BASEL, SWITZERLAND) 2016; 16:E1901. [PMID: 27845719 PMCID: PMC5134560 DOI: 10.3390/s16111901] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/07/2016] [Revised: 10/19/2016] [Accepted: 10/20/2016] [Indexed: 02/07/2023]
Abstract
A sensitive and reagentless electrochemical aptatoxisensor was developed on cobalt (II) salicylaldiimine metallodendrimer (SDD-Co(II)) doped with electro-synthesized silver nanoparticles (AgNPs) for microcystin-LR (L, l-leucine; R, l-arginine), or MC-LR, detection in the nanomolar range. The GCE|SDD-Co(II)|AgNPs aptatoxisensor was fabricated with 5' thiolated aptamer through self-assembly on the modified surface of the glassy carbon electrode (GCE) and the electronic response was measured using cyclic voltammetry (CV). Specific binding of MC-LR with the aptamer on GCE|SDD-Co(II)|AgNPs aptatoxisensor caused the formation of a complex that resulted in steric hindrance and electrostatic repulsion culminating in variation of the corresponding peak current of the electrochemical probe. The aptatoxisensor showed a linear response for MC-LR between 0.1 and 1.1 µg·L-1 and the calculated limit of detection (LOD) was 0.04 µg·L-1. In the detection of MC-LR in water samples, the aptatoxisensor proved to be highly sensitive and stable, performed well in the presence of interfering analog and was comparable to the conventional analytical techniques. The results demonstrate that the constructed MC-LR aptatoxisensor is a suitable device for routine quantification of MC-LR in freshwater and environmental samples.
Collapse
Affiliation(s)
- Mawethu P Bilibana
- SensorLab, Department of Chemistry, University of Western Cape, Robert Sobukwe Road, Bellville, Cape Town 7535, South Africa.
| | - Avril R Williams
- Department of Biological and Chemical Sciences, The University of the West Indies, Cave Hill, St. Michael BB11000, Barbados.
| | - Candice Rassie
- SensorLab, Department of Chemistry, University of Western Cape, Robert Sobukwe Road, Bellville, Cape Town 7535, South Africa.
| | - Christopher E Sunday
- SensorLab, Department of Chemistry, University of Western Cape, Robert Sobukwe Road, Bellville, Cape Town 7535, South Africa.
| | - Hlamulo Makelane
- SensorLab, Department of Chemistry, University of Western Cape, Robert Sobukwe Road, Bellville, Cape Town 7535, South Africa.
| | - Lindsay Wilson
- SensorLab, Department of Chemistry, University of Western Cape, Robert Sobukwe Road, Bellville, Cape Town 7535, South Africa.
| | - Nomaphelo Ntshongontshi
- SensorLab, Department of Chemistry, University of Western Cape, Robert Sobukwe Road, Bellville, Cape Town 7535, South Africa.
| | - Abongile N Jijana
- SensorLab, Department of Chemistry, University of Western Cape, Robert Sobukwe Road, Bellville, Cape Town 7535, South Africa.
| | - Milua Masikini
- SensorLab, Department of Chemistry, University of Western Cape, Robert Sobukwe Road, Bellville, Cape Town 7535, South Africa.
| | - Priscilla G L Baker
- SensorLab, Department of Chemistry, University of Western Cape, Robert Sobukwe Road, Bellville, Cape Town 7535, South Africa.
| | - Emmanuel I Iwuoha
- SensorLab, Department of Chemistry, University of Western Cape, Robert Sobukwe Road, Bellville, Cape Town 7535, South Africa.
| |
Collapse
|
15
|
Zhang X, He K, Zhao R, Wang L, Jin Y. Cloning of scFv from hybridomas using a rational strategy: Application as a receptor to sensitive detection microcystin-LR in water. CHEMOSPHERE 2016; 160:230-236. [PMID: 27380224 DOI: 10.1016/j.chemosphere.2016.06.084] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2016] [Revised: 06/22/2016] [Accepted: 06/24/2016] [Indexed: 06/06/2023]
Abstract
Single chain variable fragment (scFv), containing of heavy and light chains (VH and VL) joined by a short peptide linker, has been used widely for immunodetection. Nevertheless, cloning functional variable genes is still a bottle neck for the scFv generation technology. Here, a rational strategy for cloning and selecting variable region genes from an anti-microcystin-LR hybridoma was devised, then the functional VH and VL genes were recloned and assembled to scFv using splicing overlap extension PCR. The resulting scFv gene was recombinantly expressed as a soluble scFv-alkaline phosphatase fusion protein (scFv-AP) by vector PLIP6/GN. Then an indirect competitive chemiluminescent enzyme immunoassay (ic-CLEIA) for detection of microcystin-LR was developed. The half-maximum inhibition concentrations (IC50) and limits of detection (LODs, IC15) were 0.81 ± 0.04 μgL(-1) and 0.13 ± 0.03 μgL(-1), respectively. With the mean coefficient of variation lowing 8%, the mean recovery in intra-assay and inter-assay were 100.06% and 96.46%, The proposed strategy should be useful for generation scFv in a rapid and simple way.
Collapse
Affiliation(s)
- Xiuyuan Zhang
- Hebei North University, Food Safety Research Centre of Hebei North University, Zhangjiakou, 075000, China; College of Animal Science, Inner Mongolia Agricultural University, Hohhot, 010018, China
| | - Kuo He
- Hebei North University, Food Safety Research Centre of Hebei North University, Zhangjiakou, 075000, China.
| | - Ruiping Zhao
- Hebei North University, Food Safety Research Centre of Hebei North University, Zhangjiakou, 075000, China
| | - Lixia Wang
- Hebei North University, Food Safety Research Centre of Hebei North University, Zhangjiakou, 075000, China
| | - Yandan Jin
- Hebei North University, Food Safety Research Centre of Hebei North University, Zhangjiakou, 075000, China
| |
Collapse
|
16
|
Reverté L, Prieto-Simón B, Campàs M. New advances in electrochemical biosensors for the detection of toxins: Nanomaterials, magnetic beads and microfluidics systems. A review. Anal Chim Acta 2015; 908:8-21. [PMID: 26826685 DOI: 10.1016/j.aca.2015.11.050] [Citation(s) in RCA: 115] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2015] [Revised: 11/25/2015] [Accepted: 11/28/2015] [Indexed: 01/01/2023]
Abstract
The use of nanotechnology in bioanalytical devices has special advantages in the detection of toxins of interest in food safety and environmental applications. The low levels to be detected and the small size of toxins justify the increasing number of publications dealing with electrochemical biosensors, due to their high sensitivity and design versatility. The incorporation of nanomaterials in their development has been exploited to further increase their sensitivity, providing simple and fast devices, with multiplexed capabilities. This paper gives an overview of the electrochemical biosensors that have incorporated carbon and metal nanomaterials in their configurations for the detection of toxins. Biosensing systems based on magnetic beads or integrated into microfluidics systems have also been considered because of their contribution to the development of compact analytical devices. The roles of these materials, the methods used for their incorporation in the biosensor configurations as well as the advantages they provide to the analyses are summarised.
Collapse
Affiliation(s)
- Laia Reverté
- IRTA, Carretera Poble Nou km. 5.5, 43540 Sant Carles de la Ràpita, Tarragona, Spain
| | - Beatriz Prieto-Simón
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Future Industries Institute, University of South Australia, SA 5095, Australia
| | - Mònica Campàs
- IRTA, Carretera Poble Nou km. 5.5, 43540 Sant Carles de la Ràpita, Tarragona, Spain.
| |
Collapse
|
17
|
Tan F, Saucedo NM, Ramnani P, Mulchandani A. Label-Free Electrical Immunosensor for Highly Sensitive and Specific Detection of Microcystin-LR in Water Samples. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2015; 49:9256-63. [PMID: 26120934 DOI: 10.1021/acs.est.5b01674] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Microcystin-LR (MCLR) is one of the most commonly detected and toxic cyclic heptapeptide cyanotoxins released by cyanobacterial blooms in surface waters, for which sensitive and specific detection methods are necessary to carry out its recognition and quantification. Here, we present a single-walled carbon nanotube (SWCNTs)-based label-free chemiresistive immunosensor for highly sensitive and specific detection of MCLR in different source waters. MCLR was initially immobilized on SWCNTs modified interdigitated electrode, followed by incubation with monoclonal anti-MCLR antibody. The competitive binding of MCLR in sample solutions induced departure of the antibody from the antibody-antigen complexes formed on SWCNTs, resulting in change in the conductivity between source and drain of the sensor. The displacement assay greatly improved the sensitivity of the sensor compared with direct immunoassay on the same device. The immunosensor exhibited a wide linear response to log value of MCLR concentration ranging from 1 to 1000 ng/L, with a detection limit of 0.6 ng/L. This method showed good reproducibility, stability and recovery. The proposed method provides a powerful tool for rapid and sensitive monitoring of MCLR in environmental samples.
Collapse
Affiliation(s)
- Feng Tan
- †Department of Chemical and Environmental Engineering, University of California, Riverside, California 92521, United States
- ‡Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
| | - Nuvia Maria Saucedo
- †Department of Chemical and Environmental Engineering, University of California, Riverside, California 92521, United States
| | - Pankaj Ramnani
- †Department of Chemical and Environmental Engineering, University of California, Riverside, California 92521, United States
| | - Ashok Mulchandani
- †Department of Chemical and Environmental Engineering, University of California, Riverside, California 92521, United States
| |
Collapse
|
18
|
Surface-enhanced fluorescence immunosensor using Au nano-crosses for the detection of microcystin-LR. Biosens Bioelectron 2014; 62:255-60. [PMID: 25016333 DOI: 10.1016/j.bios.2014.06.064] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2014] [Revised: 06/27/2014] [Accepted: 06/30/2014] [Indexed: 01/12/2023]
Abstract
A surface-enhanced fluorescence (SEF) immunosensor for the detection of microcystin-LR was developed using Au nano-crosses as fluorescence enhancement nanoparticles and cy5 as a fluorescence label molecule. The SEF effects of cy5 in the proximity of Au nanorods and gold nano-crosses was investigated by using Au nanorods or nano-crosses coated negative-charged glass surfaces. Fluorescence measurements indicated that SEF was influenced by the size, shape and distribution of the Au nanoparticles, with an appropriate spacer layer between the Au nanoparticles and the cy5. The enhancement factor was from 2.3- to 35-fold. Under optimal conditions, the SEF immunosensor exhibited a good linear response at microcystin-LR concentrations of 0.02-16 ng mL(-1) (R(2)=0.9981). The limit of detection was 0.007 ng mL(-1) with little adsorption of microcystin-RR, microcystin-LW, and microcystin-LF. High microcystin-LR recoveries were obtained from naturally contaminated fish samples. The SEF immunosensor allows the reliable detection of microcystin-LR in seafood, and has potential in simple, sensitive detection applications.
Collapse
|
19
|
Capacitive sensing of microcystin variants of Microcystis aeruginosa using a gold immunoelectrode modified with antibodies, gold nanoparticles and polytyramine. Mikrochim Acta 2014. [DOI: 10.1007/s00604-014-1199-4] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
20
|
Pavagadhi S, Balasubramanian R. Toxicological evaluation of microcystins in aquatic fish species: current knowledge and future directions. AQUATIC TOXICOLOGY (AMSTERDAM, NETHERLANDS) 2013; 142-143:1-16. [PMID: 23948073 DOI: 10.1016/j.aquatox.2013.07.010] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2013] [Revised: 07/09/2013] [Accepted: 07/18/2013] [Indexed: 06/02/2023]
Abstract
Microcystins (MCs) are algal toxins produced intracellularly within the algal cells, and are subsequently released into the aquatic systems. An increase in the frequency and intensity of occurrence of harmful algal blooms has directed the global attention towards the presence of MCs in aquatic systems. The effects of MCs on fish have been verified in a number of studies including histological, biochemical and behavioral effects. The toxicological effects of MCs on different organs of fish are related to the exposure route (intraperitoneal injection, feeding or immersion), the mode of uptake (passive or active transport) as well as biotransformation and bioaccumulation capabilities by different organs. This paper reviews the rapidly expanding literature on the toxicological evaluation of MCs in fish from both field studies and controlled laboratory experimental investigations, integrates the current knowledge available about the mechanisms involved in MC-induced effects on fish, and points out future research directions from a cross-disciplinary perspective. In addition, the need to carry out systematic fish toxicity studies to account for possible interactions between MCs and other environmental pollutants in aquatic systems is discussed.
Collapse
Affiliation(s)
- Shruti Pavagadhi
- Singapore-Delft Water Alliance, National University of Singapore, Singapore 117576, Singapore; Department of Civil and Environmental Engineering, National University of Singapore, Singapore 117576, Singapore
| | | |
Collapse
|
21
|
An Immunosensor for Microcystins Based on Fe3O4 @Au Magnetic Nanoparticle Modified Screen-Printed Electrode. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2013. [DOI: 10.1016/s1872-2040(13)60679-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
22
|
Vilariño N, Louzao MC, Fraga M, Rodríguez LP, Botana LM. Innovative detection methods for aquatic algal toxins and their presence in the food chain. Anal Bioanal Chem 2013; 405:7719-32. [PMID: 23820950 DOI: 10.1007/s00216-013-7108-6] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2013] [Accepted: 05/31/2013] [Indexed: 01/17/2023]
Abstract
Detection of aquatic algal toxins has become critical for the protection of human health. During the last 5 years, techniques such as optical, electrochemical, and piezoelectric biosensors or fluorescent-microsphere-based assays have been developed for the detection of aquatic algal toxins, in addition to optimization of existing techniques, to achieve higher sensitivities, specificity, and speed or multidetection. New toxins have also been incorporated in the array of analytical and biological methods. The impact of the former innovation on this field is highlighted by recent changes in legal regulations, with liquid chromatography-mass spectrometry becoming the official reference method for marine lipophilic toxins and replacing the mouse bioassay in many countries. This review summarizes the large international effort to provide routine testing laboratories with fast, sensitive, high-throughput, multitoxin, validated methods for the screening of seafood, algae, and water samples.
Collapse
Affiliation(s)
- Natalia Vilariño
- Departamento de Farmacología, Facultad de Veterinaria, Universidad de Santiago de Compostela, 27002, Lugo, Spain,
| | | | | | | | | |
Collapse
|
23
|
Zhao H, Tian J, Quan X. A graphene and multienzyme functionalized carbon nanosphere-based electrochemical immunosensor for microcystin-LR detection. Colloids Surf B Biointerfaces 2013. [DOI: 10.1016/j.colsurfb.2012.10.010] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
24
|
ZHAO JING, BO BING, YIN YONGMEI, LI GENXI. GOLD NANOPARTICLES-BASED BIOSENSORS FOR BIOMEDICAL APPLICATION. ACTA ACUST UNITED AC 2012. [DOI: 10.1142/s1793984412300087] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Gold nanoparticles are the most extensively studied nanomaterials for biomedical application due to their unique properties, such as rapid and simple synthesis, large surface area, strong adsorption ability and facile conjugation to various biomolecules. The remarkable photophysical properties of gold nanoparticles have provided plenty of opportunities for the preparation of gold nanoparticles-based optical biosensors, while the excellent biocompatibility, conductivity, catalytic properties and large surface-to-volume ratio have facilitated the application of gold nanoparticles in the construction of electrochemical biosensors. In this review, we mainly detail the gold nanoparticles-based optical and electrochemical biosensors for biomedical application in the recent two years, which have exhibited greatly enhanced analytical performances in the detection of DNA, proteins and some important small molecules.
Collapse
Affiliation(s)
- JING ZHAO
- Laboratory of Biosensing Technology, School of Life Sciences, Shanghai University, Shanghai 200444, P. R. China
| | - BING BO
- Department of Oncology, The First Affiliated, Hospital of Nanjing Medical University, Nanjing 210029, P. R. China
| | - YONG-MEI YIN
- Department of Oncology, The First Affiliated, Hospital of Nanjing Medical University, Nanjing 210029, P. R. China
| | - GEN-XI LI
- Laboratory of Biosensing Technology, School of Life Sciences, Shanghai University, Shanghai 200444, P. R. China
- Department of Biochemistry and State Key Laboratory of Pharmaceutical Biotechnology, Nanjing University, Nanjing 210093, P. R. China
| |
Collapse
|
25
|
Singh S, Srivastava A, Oh HM, Ahn CY, Choi GG, Asthana RK. Recent trends in development of biosensors for detection of microcystin. Toxicon 2012; 60:878-94. [DOI: 10.1016/j.toxicon.2012.06.005] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2011] [Revised: 05/08/2012] [Accepted: 06/06/2012] [Indexed: 01/14/2023]
|
26
|
Tian J, Zhao H, Zhao H, Quan X. Photoelectrochemical immunoassay for microcystin-LR based on a fluorine-doped tin oxide glass electrode modified with a CdS-graphene composite. Mikrochim Acta 2012. [DOI: 10.1007/s00604-012-0872-8] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
27
|
Disposable immunoassay for hepatitis B surface antigen based on a graphene paste electrode functionalized with gold nanoparticles and a Nafion-cysteine conjugate. Mikrochim Acta 2012. [DOI: 10.1007/s00604-012-0805-6] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
28
|
Campàs M, Garibo D, Prieto-Simón B. Novel nanobiotechnological concepts in electrochemical biosensors for the analysis of toxins. Analyst 2012; 137:1055-67. [DOI: 10.1039/c2an15736e] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|