1
|
Chen Y, Ma C, Yang P, Mao K, Gao Y, Chen L, Wang Z, Bian Y, Shao C, Lu J. Values of apparent diffusion coefficient in pancreatic cancer patients receiving neoadjuvant therapy. BMC Cancer 2024; 24:1160. [PMID: 39294623 PMCID: PMC11412028 DOI: 10.1186/s12885-024-12934-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Accepted: 09/11/2024] [Indexed: 09/21/2024] Open
Abstract
BACKGROUND To investigate the values of apparent diffusion coefficient (ADC) for the treatment response evaluation in pancreatic cancer (PC) patients receiving neoadjuvant therapy (NAT). METHODS This study included 103 NAT patients with histologically proven PC. ADC maps were generated using monoexponential diffusion-weighted imaging (b values: 50, 800 s/mm2). Tumors' minimum, maximum, and mean ADCs were measured and compared pre- and post-NAT. Variations in ADC values measured between pre- and post-NAT completion for NAT methods (chemotherapy, chemoradiotherapy), tumor locations (head/neck, body/tail), tumor regression grade (TRG) levels (0-2, 3), N stages (N0, N1/N2) and tumor resection margin status (R0, R1), were further analyzed. RESULTS The minimum, maximum, and mean ADC values all increased dramatically after NAT, rising from 23.4 to 25.4% (all p < 0.001): mean (average: 1.626 × 10- 3 mm2/s vs. 1.315 × 10- 3 mm2/s), minimum (median: 1.274 × 10- 3 mm2/s vs. 1.034 × 10- 3 mm2/s), and maximum (average: 1.981 × 10- 3 mm2/s vs. 1.580 × 10- 3 mm2/s). The ADCs between the subgroups of all the criteria under investigation did not differ significantly for the minimum, maximum, or mean values pre- or post-NAT (P = 0.08 to 1.00). In the patients with borderline resectable PC (n = 47), the rate of tumor size changes after NAT was correlated with the pre-NAT mean ADC values (Spearman's coefficient: 0.288, P = 0.049). CONCLUSIONS The ADC values of PC increased significantly following NAT; however, the percentage increases failed to provide any predictive value for the resection margin status or TRG levels.
Collapse
Affiliation(s)
- Yufei Chen
- College of Electronic and Information Engineering, Tongji University, Shanghai, China
| | - Chao Ma
- College of Electronic and Information Engineering, Tongji University, Shanghai, China.
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, Changhai Road 168, Shanghai, 200434, China.
| | - Panpan Yang
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, Changhai Road 168, Shanghai, 200434, China
| | - Kuanzheng Mao
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, Changhai Road 168, Shanghai, 200434, China
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Yisha Gao
- Department of Pathology, Changhai Hospital of Shanghai, Naval Medical University, Shanghai, China
| | - Luguang Chen
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, Changhai Road 168, Shanghai, 200434, China
| | - Zhen Wang
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, Changhai Road 168, Shanghai, 200434, China
| | - Yun Bian
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, Changhai Road 168, Shanghai, 200434, China
| | - Chengwei Shao
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, Changhai Road 168, Shanghai, 200434, China
| | - Jianping Lu
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, Changhai Road 168, Shanghai, 200434, China
| |
Collapse
|
2
|
Bane O, Dwivedi DK, Francis ST, Karampinos D, Wu HH, Yokoo T. Quantitative body magnetic resonance imaging: how to make it work. MAGMA (NEW YORK, N.Y.) 2024:10.1007/s10334-024-01204-4. [PMID: 39259356 DOI: 10.1007/s10334-024-01204-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 08/26/2024] [Indexed: 09/13/2024]
Affiliation(s)
- Octavia Bane
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
| | | | - Susan T Francis
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, UK
| | - Dimitrios Karampinos
- Institute of Diagnostic and Interventional Radiology, School of Medicine and Health, Technical University of Munich, Munich, Germany
| | - Holden H Wu
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, CA, USA
| | - Takeshi Yokoo
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
3
|
Liu MM, Dyke J, Gladytz T, Jasse J, Bolger I, Calle S, Pavaluri S, Crews T, Seshan S, Salvatore S, Stillman I, Muthukumar T, Taouli B, Farouk S, Lewis S, Bane O. Quantification of Multi-Compartment Flow with Spectral Diffusion MRI. ARXIV 2024:arXiv:2408.06427v1. [PMID: 39184540 PMCID: PMC11343220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Subscribe] [Scholar Register] [Indexed: 08/27/2024]
Abstract
Purpose Estimation of multi-compartment intravoxel 'flow' in fD in ml/100g/min with multi-b-value diffusion weighted imaging and a multi-Gaussian model in the kidneys. Theory and Methods A multi-Gaussian model of intravoxel flow using water transport time to quantify f D (ml/100g/min) is presented and simulated. Multi-compartment anisotropic DWI signal is simulated with Rician noise and SNR=50 and analyzed with a rigid bi-exponential, a rigid tri-exponential and diffusion spectrum imaging model of intravoxel incoherent motion (spectral diffusion) to study extraction of multi-compartment flow. The regularization parameter for spectral diffusion is varied to study the impact on the resulting spectrum and computation speed. The application is demonstrated in a two-center study of 54 kidney allografts with 9 b-value advanced DWI that were split by function (CKD-EPI 2021 eGFR<45ml/min/1.73m2) and fibrosis (Banff 2017 interstitial fibrosis and tubular atrophy score 0-6) to demonstrate multi-compartment flow of various kidney pathologies. Results Simulation of anisotropic multi-compartment flow from spectral diffusion demonstrated strong correlation to truth for both three-compartment anisotropic diffusion ( y = 1.08 x + 0.1 , R 2 = 0.71 ) and two-compartment anisotropic diffusion ( y = 0.91 + 0.6 , R 2 = 0.74 ), outperforming rigid models in cases of variable compartment number. Use of a fixed regularization parameter set to λ = 0.1 increased computation up to 208-fold and agreed with voxel-wise cross-validated regularization (concordance correlation coefficient=0.99). Spectral diffusion of renal allografts showed decreasing trend of tubular and vascular flow with higher levels of fibrosis, and significant increase in tissue parenchyma flow (f-stat=3.86, p=0.02). Tubular f D was significantly decreased in allografts with impaired function (eGFR<45ml/min/1.73m2)(Mann-Whitney U t-stat=-2.14, p=0.04). Conclusions Quantitative multi-compartment intravoxel 'flow' can be estimated in ml/100g/min with f D from multi-Gaussian diffusion with water transport time, even with moderate anisotropy such as in kidneys. The use of spectral diffusion with a multi-Gaussian model and a fixed regularization parameter is particularly promising in organs such as the kidney with variable numbers of physiologic compartments.
Collapse
Affiliation(s)
- Mira M. Liu
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Jonathan Dyke
- Department of Radiology/Citigroup Biomedical Imaging Center, Weill Cornell Medicine, New York, NY, USA
| | - Thomas Gladytz
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Jonas Jasse
- Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - Ian Bolger
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Sergio Calle
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Swathi Pavaluri
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Tanner Crews
- Department of Radiology/Citigroup Biomedical Imaging Center, Weill Cornell Medicine, New York, NY, USA
| | - Surya Seshan
- Department of Pathology, Weill Cornell Medicine, New York, NY, USA
| | - Steven Salvatore
- Department of Pathology, Weill Cornell Medicine, New York, NY, USA
| | - Isaac Stillman
- Department of Pathology, Icahn School of Medicine at Mount Sinai, Mount Sinai Hospital, New York, NY, USA
| | - Thangamani Muthukumar
- Department of Nephrology and Kidney Transplantation Medicine, Weill Cornell Medicine, New York, NY, USA
| | - Bachir Taouli
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, Mount Sinai Hospital, New York, NY, USA
| | - Samira Farouk
- Transplant Nephrology, Icahn School of Medicine at Mount Sinai, Mount Sinai Hospital, New York, NY, USA
| | - Sara Lewis
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, Mount Sinai Hospital, New York, NY, USA
| | - Octavia Bane
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, Mount Sinai Hospital, New York, NY, USA
| |
Collapse
|
4
|
Loh M, Führes T, Stuprich C, Benkert T, Bickelhaupt S, Uder M, Laun FB. Effect of simultaneous multislice imaging, slice properties, and repetition time on the measured magnetic resonance biexponential intravoxel incoherent motion in the liver. PLoS One 2024; 19:e0306996. [PMID: 39121035 PMCID: PMC11315316 DOI: 10.1371/journal.pone.0306996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Accepted: 06/26/2024] [Indexed: 08/11/2024] Open
Abstract
OBJECTIVES This study aims to investigate the previously reported dependency of intravoxel incoherent motion (IVIM) parameters on simultaneous multislice (SMS) acquisition and repetition time (TR). This includes the influence of slice thickness, slice gaps, and slice order on measured IVIM parameters. MATERIALS AND METHODS Diffusion-weighted imaging (DWI) of the liver was performed on 10 healthy volunteers (aged 20-30 years) at 3T with a slice thickness of 5 mm, a slice gap of 5 mm, and a linear slice order. Diffusion-weighted images were acquired with 19 b-values (0-800 s/mm2) using both conventional slice excitation with an acceleration factor of one (AF1) and SMS excitation with an acceleration factor of three (AF3). Each of these measurements were carried out with two repetition times (TRs)- 1,300 ms (prefix s) and 4,500 ms (prefix l)-resulting in four different combinations: sAF1, sAF3, lAF1, and lAF3. Five volunteers underwent additional measurements using a 10 mm slice thickness and with AF1. Median signal values in the liver were used to determine the biexponential IVIM parameters. Statistical significances were assessed using the Kruskal-Wallis test, Wilcoxon signed-rank test, and Student's t-test. In-silico investigations were also used to interpret the data. RESULTS There were no significant differences between the biexponential IVIM parameters acquired from sAF1, sAF3, lAF1, and lAF3. Median values of the perfusion fraction f were as follows: 29.9% (sAF1), 26.9% (sAF3), 28.1% (lAF1), and 27.5% (lAF3). In the 10 mm-thick slices, f decreased from 31.3% (lAF1) to 27.4% (sAF1) (p = 0.141). CONCLUSION The slice excitation mode did not appear to have any significant influence on the biexponential IVIM parameters. However, our simulations, as well as values reported from previous publications, show that slice thickness, slice gaps, and slice order are relevant and should thus be reported in IVIM studies.
Collapse
Affiliation(s)
- Martin Loh
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Tobit Führes
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Christoph Stuprich
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Thomas Benkert
- MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Sebastian Bickelhaupt
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Michael Uder
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Frederik Bernd Laun
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| |
Collapse
|
5
|
Gilani N, Mikheev A, Brinkmann IM, Kumbella M, Babb JS, Basukala D, Wetscherek A, Benkert T, Chandarana H, Sigmund EE. Spatial profiling of in vivo diffusion-weighted MRI parameters in the healthy human kidney. MAGMA (NEW YORK, N.Y.) 2024:10.1007/s10334-024-01159-6. [PMID: 38703246 DOI: 10.1007/s10334-024-01159-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 01/17/2024] [Accepted: 03/26/2024] [Indexed: 05/06/2024]
Abstract
OBJECTIVE Diffusion-weighted MRI is a technique that can infer microstructural and microcirculatory features from biological tissue, with particular application to renal tissue. There is extensive literature on diffusion tensor imaging (DTI) of anisotropy in the renal medulla, intravoxel incoherent motion (IVIM) measurements separating microstructural from microcirculation effects, and combinations of the two. However, interpretation of these features and adaptation of more specific models remains an ongoing challenge. One input to this process is a whole organ distillation of corticomedullary contrast of diffusion metrics, as has been explored for other renal biomarkers. MATERIALS AND METHODS In this work, we probe the spatial dependence of diffusion MRI metrics with concentrically layered segmentation in 11 healthy kidneys at 3 T. The metrics include those from DTI, IVIM, a combined approach titled "REnal Flow and Microstructure AnisotroPy (REFMAP)", and a multiply encoded model titled "FC-IVIM" providing estimates of fluid velocity and branching length. RESULTS Fractional anisotropy decreased from the inner kidney to the outer kidney with the strongest layer correlation in both parenchyma (including cortex and medulla) and medulla with Spearman correlation coefficients and p-values (r, p) of (0.42, <0.001) and (0.37, <0.001), respectively. Also, dynamic parameters derived from the three models significantly decreased with a high correlation from the inner to the outer parenchyma or medulla with (r, p) ranges of (0.46-0.55, <0.001). CONCLUSIONS These spatial trends might find implications for indirect assessments of kidney physiology and microstructure using diffusion MRI.
Collapse
Affiliation(s)
- Nima Gilani
- Department of Radiology, Center for Advanced Imaging Innovation and Research (CAI2R), Center for Biomedical Imaging, NYU Langone Health, New York, USA.
| | - Artem Mikheev
- Department of Radiology, Center for Advanced Imaging Innovation and Research (CAI2R), Center for Biomedical Imaging, NYU Langone Health, New York, USA
| | | | - Malika Kumbella
- Department of Radiology, Center for Advanced Imaging Innovation and Research (CAI2R), Center for Biomedical Imaging, NYU Langone Health, New York, USA
| | - James S Babb
- Department of Radiology, Center for Advanced Imaging Innovation and Research (CAI2R), Center for Biomedical Imaging, NYU Langone Health, New York, USA
| | - Dibash Basukala
- Department of Radiology, Center for Advanced Imaging Innovation and Research (CAI2R), Center for Biomedical Imaging, NYU Langone Health, New York, USA
| | - Andreas Wetscherek
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, UK
| | - Thomas Benkert
- MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Hersh Chandarana
- Department of Radiology, Center for Advanced Imaging Innovation and Research (CAI2R), Center for Biomedical Imaging, NYU Langone Health, New York, USA
| | - Eric E Sigmund
- Department of Radiology, Center for Advanced Imaging Innovation and Research (CAI2R), Center for Biomedical Imaging, NYU Langone Health, New York, USA
| |
Collapse
|
6
|
Zhao K, Seeliger E, Niendorf T, Liu Z. Noninvasive Assessment of Diabetic Kidney Disease With MRI: Hype or Hope? J Magn Reson Imaging 2024; 59:1494-1513. [PMID: 37675919 DOI: 10.1002/jmri.29000] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 08/22/2023] [Accepted: 08/23/2023] [Indexed: 09/08/2023] Open
Abstract
Owing to the increasing prevalence of diabetic mellitus, diabetic kidney disease (DKD) is presently the leading cause of chronic kidney disease and end-stage renal disease worldwide. Early identification and disease interception is of paramount clinical importance for DKD management. However, current diagnostic, disease monitoring and prognostic tools are not satisfactory, due to their low sensitivity, low specificity, or invasiveness. Magnetic resonance imaging (MRI) is noninvasive and offers a host of contrast mechanisms that are sensitive to pathophysiological changes and risk factors associated with DKD. MRI tissue characterization involves structural and functional information including renal morphology (kidney volume (TKV) and parenchyma thickness using T1- or T2-weighted MRI), renal microstructure (diffusion weighted imaging, DWI), renal tissue oxygenation (blood oxygenation level dependent MRI, BOLD), renal hemodynamics (arterial spin labeling and phase contrast MRI), fibrosis (DWI) and abdominal or perirenal fat fraction (Dixon MRI). Recent (pre)clinical studies demonstrated the feasibility and potential value of DKD evaluation with MRI. Recognizing this opportunity, this review outlines key concepts and current trends in renal MRI technology for furthering our understanding of the mechanisms underlying DKD and for supplementing clinical decision-making in DKD. Progress in preclinical MRI of DKD is surveyed, and challenges for clinical translation of renal MRI are discussed. Future directions of DKD assessment and renal tissue characterization with (multi)parametric MRI are explored. Opportunities for discovery and clinical break-through are discussed including biological validation of the MRI findings, large-scale population studies, standardization of DKD protocols, the synergistic connection with data science to advance comprehensive texture analysis, and the development of smart and automatic data analysis and data visualization tools to further the concepts of virtual biopsy and personalized DKD precision medicine. We hope that this review will convey this vision and inspire the reader to become pioneers in noninvasive assessment and management of DKD with MRI. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Kaixuan Zhao
- Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
- Department of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Southern Medical University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Artificial Intelligence in Medical Image Analysis and Application, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Erdmann Seeliger
- Institute of Translational Physiology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Zaiyi Liu
- Department of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Southern Medical University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Artificial Intelligence in Medical Image Analysis and Application, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| |
Collapse
|
7
|
Rasmussen CW, Bøgh N, Ringgaard S, Birn H, Vaeggemose M, Schulte RF, Laustsen C. Daytime Variation in Kidney Perfusion, Oxygenation, and Sodium Concentration Assessed by Multiparametric MRI in Healthy Volunteers. J Magn Reson Imaging 2024; 59:1603-1611. [PMID: 37656067 DOI: 10.1002/jmri.28983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 08/14/2023] [Accepted: 08/15/2023] [Indexed: 09/02/2023] Open
Abstract
BACKGROUND MRI can provide information on kidney structure, perfusion, and oxygenation. Furthermore, it allows for the assessment of kidney sodium concentrations and handling, allowing multiparametric evaluation of kidney physiology. Multiparametric MRI is promising for establishing prognosis and monitoring treatment responses in kidney diseases, but its intraindividual variation during the day is unresolved. PURPOSE To investigate the variation in multiparametric MRI measurements from the morning to the evening. STUDY TYPE Prospective. POPULATION Ten healthy volunteers, aged 29 ± 5 without history of kidney disease. FIELD STRENGTH/SEQUENCE 3 T/T1 mapping, blood-oxygen level dependent imaging, arterial spin labeling perfusion imaging, diffusion weighted imaging, and sodium imaging. ASSESSMENT A multiparametric MRI protocol, yielding T1, R2*, ADC, renal blood flow and renal sodium levels, was acquired in the morning, noon, and evening. The participants were fasting prior to the first examination. Urine biochemical analyses were performed to complement MRI data. The cortex and medulla were analyzed separately in a semi-automatic fashion, and gradients of total sodium concentration (TSC) and R2* gradients were calculated from outer cortex to inner medulla. STATISTICAL TEST Analyses of variance and mixed-effects models to estimate differences from time of day. Coefficients of variation to assess variability within and between participants. A P-value <0.05 was considered statistically significant. RESULTS The coefficients of variation varied from 5% to 18% for proton-based parametric sequences, while it was 38% for TSC over a day. DATA CONCLUSION Multiparametric MRI is stable over the day. The coefficients of variation over a day were lower for proton multiparametric MRI, but higher for sodium MRI. EVIDENCE LEVEL 2 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Camilla W Rasmussen
- The MR Research Center, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Nikolaj Bøgh
- The MR Research Center, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Steffen Ringgaard
- The MR Research Center, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Henrik Birn
- Department of Renal Medicine, Aarhus University Hospital, Aarhus, Denmark
- Department of Biomedicine, Aarhus University, Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Michael Vaeggemose
- The MR Research Center, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
- GE HealthCare, Broendby, Denmark
| | | | - Christoffer Laustsen
- The MR Research Center, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
8
|
梁 灿, 李 莹, 贺 晓. [Functional MRI assessment of microstructural and perfusion changes in the kidneys of rats with intrauterine growth restriction]. ZHONGGUO DANG DAI ER KE ZA ZHI = CHINESE JOURNAL OF CONTEMPORARY PEDIATRICS 2024; 26:289-296. [PMID: 38557382 PMCID: PMC10986373 DOI: 10.7499/j.issn.1008-8830.2309004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Accepted: 01/28/2024] [Indexed: 04/04/2024]
Abstract
OBJECTIVES To explore the value of functional magnetic resonance imaging (MRI) techniques, including intravoxel incoherent motion (IVIM), T1 mapping, and T2 mapping, in assessing the microstructural and perfusion changes in the kidneys of rats with intrauterine growth restriction (IUGR). METHODS An IUGR rat model was established through a low-protein diet during pregnancy. Offspring from pregnant rats on a low-protein diet were randomly divided into an IUGR 8-week group and an IUGR 12-week group, while offspring from pregnant rats on a normal diet were divided into a normal 8-week group and a normal 12-week group (n=8 for each group). The apparent diffusion coefficient (ADC), true diffusion coefficient (Dt), pseudo-diffusion coefficient (D*), perfusion fraction (f), T1 value, and T2 value of the renal cortex and medulla were compared, along with serum creatinine and blood urea nitrogen levels among the groups. RESULTS The Dt value in the renal medulla was higher in the IUGR 12-week group than in the IUGR 8-week group, and the D* value in the renal medulla was lower in the IUGR 12-week group than in both the normal 12-week group and the IUGR 8-week group (P<0.05). The T1 value in the renal medulla was higher than in the cortex in the IUGR 8-week group, and the T1 value in the renal medulla was higher in the IUGR 12-week group than in both the IUGR 8-week group and the normal 12-week group, with the cortical T1 value in the IUGR 12-week group also being higher than that in the normal 12-week group (P<0.05). The T2 values in the renal medulla were higher than those in the cortex across all groups (P<0.05). There were no significant differences in the T2 values of either the cortex or medulla among the groups (P>0.05). There were no significant differences in serum creatinine and blood urea nitrogen levels among the groups (P>0.05). Glomerular hyperplasia and hypertrophy without significant fibrotic changes were observed in the IUGR 8-week group, whereas glomerular atrophy, cystic stenosis, and interstitial inflammatory infiltration and fibrosis were seen in the IUGR 12-week group. CONCLUSIONS IVIM MRI can be used to assess and dynamically observe the microstructural and perfusion damage in the kidneys of IUGR rats. MRI T1 mapping can be used to evaluate kidney damage in IUGR rats, and the combination of MRI T1 mapping and T2 mapping can further differentiate renal fibrosis in IUGR rats.
Collapse
Affiliation(s)
- 灿 梁
- 中南大学湘雅二医院新生儿疾病研究室,湖南长沙410011
| | - 莹 李
- 中南大学湘雅二医院新生儿疾病研究室,湖南长沙410011
| | | |
Collapse
|
9
|
Bane O, Lewis SC, Lim RP, Carney BW, Shah A, Fananapazir G. Contemporary and Emerging MRI Strategies for Assessing Kidney Allograft Complications: Arterial Stenosis and Parenchymal Injury, From the AJR Special Series on Imaging of Fibrosis. AJR Am J Roentgenol 2024; 222:e2329418. [PMID: 37315018 PMCID: PMC11006565 DOI: 10.2214/ajr.23.29418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
MRI plays an important role in the evaluation of kidney allografts for vascular complications as well as parenchymal insults. Transplant renal artery stenosis, the most common vascular complication of kidney transplant, can be evaluated by MRA using gadolinium and nongadolinium contrast agents as well as by unenhanced MRA techniques. Parenchymal injury occurs through a variety of pathways, including graft rejection, acute tubular injury, BK polyomavirus infection, drug-induced interstitial nephritis, and pyelonephritis. Investigational MRI techniques have sought to differentiate among these causes of dysfunction as well as to assess the degree of interstitial fibrosis or tubular atrophy (IFTA)-the common end pathway for all of these processes-which is currently evaluated by invasively obtained core biopsies. Some of these MRI sequences have shown promise in not only assessing the cause of parenchymal injury but also assessing IFTA noninvasively. This review describes current clinically used MRI techniques and previews promising investigational MRI techniques for assessing complications of kidney grafts.
Collapse
Affiliation(s)
- Octavia Bane
- Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY
| | - Sara C Lewis
- Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY
| | - Ruth P Lim
- Department of Radiology and Department of Surgery, University of Melbourne, Austin Health, Melbourne, Australia
| | - Benjamin W Carney
- Department of Radiology, University of California Davis Medical Center, 4860 Y St, Ste 3100, Sacramento, CA 95816
| | - Amar Shah
- Department of Radiology, Mayo Clinic Arizona, Phoenix, AZ
| | - Ghaneh Fananapazir
- Department of Radiology, University of California Davis Medical Center, 4860 Y St, Ste 3100, Sacramento, CA 95816
| |
Collapse
|
10
|
Selby NM, Francis ST. Assessment of Acute Kidney Injury using MRI. J Magn Reson Imaging 2024. [PMID: 38334370 DOI: 10.1002/jmri.29281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 01/19/2024] [Accepted: 01/23/2024] [Indexed: 02/10/2024] Open
Abstract
There has been growing interest in using quantitative magnetic resonance imaging (MRI) to describe and understand the pathophysiology of acute kidney injury (AKI). The ability to assess kidney blood flow, perfusion, oxygenation, and changes in tissue microstructure at repeated timepoints is hugely appealing, as this offers new possibilities to describe nature and severity of AKI, track the time-course to recovery or progression to chronic kidney disease (CKD), and may ultimately provide a method to noninvasively assess response to new therapies. This could have significant clinical implications considering that AKI is common (affecting more than 13 million people globally every year), harmful (associated with short and long-term morbidity and mortality), and currently lacks specific treatments. However, this is also a challenging area to study. After the kidney has been affected by an initial insult that leads to AKI, complex coexisting processes ensue, which may recover or can progress to CKD. There are various preclinical models of AKI (from which most of our current understanding derives), and these differ from each other but more importantly from clinical AKI. These aspects are fundamental to interpreting the results of the different AKI studies in which renal MRI has been used, which encompass different settings of AKI and a variety of MRI measures acquired at different timepoints. This review aims to provide a comprehensive description and interpretation of current studies (both preclinical and clinical) in which MRI has been used to assess AKI, and discuss future directions in the field. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 3.
Collapse
Affiliation(s)
- Nicholas M Selby
- Centre for Kidney Research and Innovation, Academic Unit for Translational Medical Sciences, School of Medicine, University of Nottingham, Nottingham, UK
- Department of Renal Medicine, University Hospitals of Derby and Burton NHS Foundation Trust, Derby, UK
| | - Susan T Francis
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
- NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and The University of Nottingham, Nottingham, UK
| |
Collapse
|
11
|
Wolf M, Darwish O, Neji R, Eder M, Sunder-Plassmann G, Heinz G, Robinson SD, Schmid AI, Moser EV, Sinkus R, Meyerspeer M. Magnetic resonance elastography resolving all gross anatomical segments of the kidney during controlled hydration. Front Physiol 2024; 15:1327407. [PMID: 38384795 PMCID: PMC10880033 DOI: 10.3389/fphys.2024.1327407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Accepted: 01/24/2024] [Indexed: 02/23/2024] Open
Abstract
Introduction: Magnetic resonance elastography (MRE) is a non-invasive method to quantify biomechanical properties of human tissues. It has potential in diagnosis and monitoring of kidney disease, if established in clinical practice. The interplay of flow and volume changes in renal vessels, tubule, urinary collection system and interstitium is complex, but physiological ranges of in vivo viscoelastic properties during fasting and hydration have never been investigated in all gross anatomical segments simultaneously. Method: Ten healthy volunteers underwent two imaging sessions, one following a 12-hour fasting period and the second after a drinking challenge of >10 mL per kg body weight (60-75 min before the second examination). High-resolution renal MRE was performed using a novel driver with rotating eccentric mass placed at the posterior-lateral wall to couple waves (50 Hz) to the kidney. The biomechanical parameters, shear wave speed (cs in m/s), storage modulus (Gd in kPa), loss modulus (Gl in kPa), phase angle ( Υ = 2 π atan G l G d ) and attenuation (α in 1/mm) were derived. Accurate separation of gross anatomical segments was applied in post-processing (whole kidney, cortex, medulla, sinus, vessel). Results: High-quality shear waves coupled into all gross anatomical segments of the kidney (mean shear wave displacement: 163 ± 47 μm, mean contamination of second upper harmonics <23%, curl/divergence: 4.3 ± 0.8). Regardless of the hydration state, median Gd of the cortex and medulla (0.68 ± 0.11 kPa) was significantly higher than that of the sinus and vessels (0.48 ± 0.06 kPa), and consistently, significant differences were found in cs, Υ , and Gl (all p < 0.001). The viscoelastic parameters of cortex and medulla were not significantly different. After hydration sinus exhibited a small but significant reduction in median Gd by -0.02 ± 0.04 kPa (p = 0.01), and, consequently, the cortico-sinusoidal-difference in Gd increased by 0.04 ± 0.07 kPa (p = 0.05). Only upon hydration, the attenuation in vessels became lower (0.084 ± 0.013 1/mm) and differed significantly from the whole kidney (0.095 ± 0.007 1/mm, p = 0.01). Conclusion: High-resolution renal MRE with an innovative driver and well-defined 3D segmentation can resolve all renal segments, especially when including the sinus in the analysis. Even after a prolonged hydration period the approach is sensitive to small hydration-related changes in the sinus and in the cortico-sinusoidal-difference.
Collapse
Affiliation(s)
- Marcos Wolf
- High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Omar Darwish
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, United Kingdom
| | - Radhouene Neji
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
| | - Michael Eder
- Department of Medicine III, Division of Nephrology and Dialysis, General Hospital and Medical University of Vienna, Vienna, Austria
| | - Gere Sunder-Plassmann
- Department of Medicine III, Division of Nephrology and Dialysis, General Hospital and Medical University of Vienna, Vienna, Austria
| | - Gertraud Heinz
- Institut für Diagnostische und Interventionelle Radiologie, Universitätsklinikum St. Pölten, Sankt Pölten, Austria
| | - Simon Daniel Robinson
- High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Centre of Advanced Imaging, University of Queensland, Brisbane, QLD, Australia
| | - Albrecht Ingo Schmid
- High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Ewald V. Moser
- High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Ralph Sinkus
- Institut National de La Santé et de La Recherche Médicale, U1148, Laboratory for Vascular Translational Science, Paris, France
| | - Martin Meyerspeer
- High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
12
|
Zhao J, Wang M, Ding X, Fu Y, Peng C, Kang H, Guo H, Bai X, Huang Q, Zhou S, Zhang X, Liu K, Li L, Ye H, Zhang X, Ma X, Wang H. Intravoxel Incoherent Motion Diffusion-Weighted MR Imaging and Venous Tumor Thrombus Consistency in Renal Cell Carcinoma. J Magn Reson Imaging 2024; 59:134-145. [PMID: 37134147 DOI: 10.1002/jmri.28763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2023] [Revised: 04/18/2023] [Accepted: 04/19/2023] [Indexed: 05/05/2023] Open
Abstract
BACKGROUND Venous tumor thrombus (VTT) consistency of renal cell carcinoma (RCC) is an important consideration in nephrectomy plus thrombectomy. However, evaluation of VTT consistency through preoperative MR imaging is lacking. PURPOSE To evaluate VTT consistency of RCC through intravoxel incoherent motion-diffusion weighted imaging (IVIM-DWI) derived parameters (Dt , Dp , f, and ADC) and the apparent diffusion coefficient (ADC) value. STUDY TYPE Retrospective. POPULATION One hundred and nineteen patients (aged 55.8 ± 11.5 years, 85 male) with histologically-proven RCC and VTT who underwent radical resection. FIELD STRENGTH/SEQUENCES 3.0-T; two-dimensional single-shot diffusion-weighted echo planar imaging sequence at 9 b-values (0-800 s/mm2 ). ASSESSMENT IVIM parameters and ADC values of the primary tumor and the VTT were calculated. The VTT consistency (friable vs. solid) was determined through intraoperative findings of two urologists. The accuracy of VTT consistency classification based on the individual IVIM parameters of primary tumors and of VTT, and based on models combining parameters, was assessed. Type of operation, intra-operative blood loss, and operation length were recorded. STATISTICAL TESTS Shapiro-Wilk test; Mann-Whitney U test; Student's t-test; Chi-square test; Receiver operating characteristic (ROC) analysis. Statistical significance level was P < 0.05. RESULTS Of the enrolled 119 patients, 33 patients (27.7%) had friable VTT. Patients with friable VTT were significantly more likely to experience open surgery, have significantly more intraoperative blood loss, and significantly longer operative duration. The area under the ROC curve (AUC) values of Dt of the primary tumor and VTT in classifying VTT consistency were 0.758 (95% CI 0.671-0.832) and 0.712 (95% CI 0.622-0.792), respectively. The AUC value of the model combining Dp and Dt of VTT was 0.800 (95% CI 0.717-0.868). Furthermore, the AUC of the model combining Dp and Dt of VTT and Dt of the primary tumor was 0.886 (95% CI 0.814-0.937). CONCLUSION IVIM-derived parameters had the potential to predict VTT consistency of RCC. EVIDENCE LEVEL 3 Technical Efficacy: Stage 2.
Collapse
Affiliation(s)
- Jian Zhao
- Department of Radiology, First Medical Center, Chinese PLA General Hospital, Beijing, China
- Department of Radiology, Armed Police Force Hospital of Sichuan, Leshan, Sichuan, China
| | - Meifeng Wang
- Department of Radiology, First Medical Center, Chinese PLA General Hospital, Beijing, China
- Department of Radiology, Sixth Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Xiaohui Ding
- Department of Pathology, First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Yonggui Fu
- Department of Radiology, First Medical Center, Chinese PLA General Hospital, Beijing, China
- Department of Radiology, Sixth Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Cheng Peng
- Department of Urology, Chinese PLA General Hospital, Beijing, China
| | - Huanhuan Kang
- Department of Radiology, First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Huiping Guo
- Department of Radiology, First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Xu Bai
- Department of Radiology, First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Qingbo Huang
- Department of Urology, Chinese PLA General Hospital, Beijing, China
| | - Shaopeng Zhou
- Department of Radiology, First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Xiaojing Zhang
- Department of Radiology, First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Kan Liu
- Department of Urology, Chinese PLA General Hospital, Beijing, China
| | - Lin Li
- Department of Innovative Medical Research, Hospital Management Institute, Chinese PLA General Hospital, Beijing, China
| | - Huiyi Ye
- Department of Radiology, First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Xu Zhang
- Department of Urology, Chinese PLA General Hospital, Beijing, China
| | - Xin Ma
- Department of Urology, Chinese PLA General Hospital, Beijing, China
| | - Haiyi Wang
- Department of Radiology, First Medical Center, Chinese PLA General Hospital, Beijing, China
| |
Collapse
|
13
|
Wang B, Wang Y, Wang J, Jin C, Zhou R, Guo J, Zhang H, Wang M. Multiparametric Magnetic Resonance Investigations on Acute and Long-Term Kidney Injury. J Magn Reson Imaging 2024; 59:43-57. [PMID: 37246343 DOI: 10.1002/jmri.28784] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2022] [Revised: 04/29/2023] [Accepted: 05/01/2023] [Indexed: 05/30/2023] Open
Abstract
Acute kidney injury (AKI) is a frequent complication of critical illness and carries a significant risk of short- and long-term mortality. The prediction of the progression of AKI to long-term injury has been difficult for renal disease treatment. Radiologists are keen for the early detection of transition from AKI to long-term kidney injury, which would help in the preventive measures. The lack of established methods for early detection of long-term kidney injury underscores the pressing needs of advanced imaging technology that reveals microscopic tissue alterations during the progression of AKI. Fueled by recent advances in data acquisition and post-processing methods of magnetic resonance imaging (MRI), multiparametric MRI is showing great potential as a diagnostic tool for many kidney diseases. Multiparametric MRI studies offer a precious opportunity for real-time noninvasive monitoring of pathological development and progression of AKI to long-term injury. It provides insight into renal vasculature and function (arterial spin labeling, intravoxel incoherent motion), tissue oxygenation (blood oxygen level-dependent), tissue injury and fibrosis (diffusion tensor imaging, diffusion kurtosis imaging, T1 and T2 mapping, quantitative susceptibility mapping). The multiparametric MRI approach is highly promising but the longitudinal investigation on the transition of AKI to irreversible long-term impairment is largely ignored. Further optimization and implementation of renal MR methods in clinical practice will enhance our comprehension of not only AKI but chronic kidney diseases. Novel imaging biomarkers for microscopic renal tissue alterations could be discovered and benefit the preventative interventions. This review explores recent MRI applications on acute and long-term kidney injury while addressing lingering challenges, with emphasis on the potential value of the development of multiparametric MRI for renal imaging on clinical systems. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Bin Wang
- Department of Medical Imaging, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China
- Department of Medical Imaging, Shanxi Medical University, Taiyuan, Shanxi, China
| | - Yongfang Wang
- Department of Medical Imaging, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China
| | - Jing Wang
- Department of Nuclear Medicine and PET Center, The Second Hospital of Zhejiang University School of Medicine, Hangzhou, China
- Key Laboratory of Medical Molecular Imaging of Zhejiang Province, Hangzhou, China
| | - Chentao Jin
- Department of Nuclear Medicine and PET Center, The Second Hospital of Zhejiang University School of Medicine, Hangzhou, China
- Key Laboratory of Medical Molecular Imaging of Zhejiang Province, Hangzhou, China
| | - Rui Zhou
- Department of Nuclear Medicine and PET Center, The Second Hospital of Zhejiang University School of Medicine, Hangzhou, China
- Key Laboratory of Medical Molecular Imaging of Zhejiang Province, Hangzhou, China
| | - Jinxia Guo
- GE Healthcare, MR Research China, Beijing, China
| | - Hong Zhang
- Department of Nuclear Medicine and PET Center, The Second Hospital of Zhejiang University School of Medicine, Hangzhou, China
- Key Laboratory of Medical Molecular Imaging of Zhejiang Province, Hangzhou, China
- Key Laboratory for Biomedical Engineering of Ministry of Education, Zhejiang University, Hangzhou, China
- College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China
| | - Min Wang
- Key Laboratory for Biomedical Engineering of Ministry of Education, Zhejiang University, Hangzhou, China
- College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China
| |
Collapse
|
14
|
Bane O, Seeliger E, Cox E, Stabinska J, Bechler E, Lewis S, Hickson LJ, Francis S, Sigmund E, Niendorf T. Renal MRI: From Nephron to NMR Signal. J Magn Reson Imaging 2023; 58:1660-1679. [PMID: 37243378 PMCID: PMC11025392 DOI: 10.1002/jmri.28828] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 05/11/2023] [Accepted: 05/12/2023] [Indexed: 05/28/2023] Open
Abstract
Renal diseases pose a significant socio-economic burden on healthcare systems. The development of better diagnostics and prognostics is well-recognized as a key strategy to resolve these challenges. Central to these developments are MRI biomarkers, due to their potential for monitoring of early pathophysiological changes, renal disease progression or treatment effects. The surge in renal MRI involves major cross-domain initiatives, large clinical studies, and educational programs. In parallel with these translational efforts, the need for greater (patho)physiological specificity remains, to enable engagement with clinical nephrologists and increase the associated health impact. The ISMRM 2022 Member Initiated Symposium (MIS) on renal MRI spotlighted this issue with the goal of inspiring more solutions from the ISMRM community. This work is a summary of the MIS presentations devoted to: 1) educating imaging scientists and clinicians on renal (patho)physiology and demands from clinical nephrologists, 2) elucidating the connection of MRI parameters with renal physiology, 3) presenting the current state of leading MR surrogates in assessing renal structure and functions as well as their next generation of innovation, and 4) describing the potential of these imaging markers for providing clinically meaningful renal characterization to guide or supplement clinical decision making. We hope to continue momentum of recent years and introduce new entrants to the development process, connecting (patho)physiology with (bio)physics, and conceiving new clinical applications. We envision this process to benefit from cross-disciplinary collaboration and analogous efforts in other body organs, but also to maximally leverage the unique opportunities of renal physiology. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.
Collapse
Affiliation(s)
- Octavia Bane
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York City, New York, USA
- Icahn School of Medicine at Mount Sinai, BioMedical Engineering and Imaging Institute, New York City, New York, USA
| | - Erdmann Seeliger
- Institute of Translational Physiology, Charité-University Medicine Berlin, Berlin, Germany
| | - Eleanor Cox
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
| | - Julia Stabinska
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Eric Bechler
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Düsseldorf, Germany
| | - Sara Lewis
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York City, New York, USA
| | - LaTonya J Hickson
- Division of Nephrology and Hypertension, Mayo Clinic, Jacksonville, Florida, USA
| | - Sue Francis
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
| | - Eric Sigmund
- Bernard and Irene Schwartz Center for Biomedical Imaging Center for Advanced Imaging Innovation and Research (CAI2R), New York University Langone Health, New York City, New York, USA
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| |
Collapse
|
15
|
Fokkinga E, Hernandez-Tamames JA, Ianus A, Nilsson M, Tax CMW, Perez-Lopez R, Grussu F. Advanced Diffusion-Weighted MRI for Cancer Microstructure Assessment in Body Imaging, and Its Relationship With Histology. J Magn Reson Imaging 2023. [PMID: 38032021 DOI: 10.1002/jmri.29144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 10/30/2023] [Accepted: 10/31/2023] [Indexed: 12/01/2023] Open
Abstract
Diffusion-weighted magnetic resonance imaging (DW-MRI) aims to disentangle multiple biological signal sources in each imaging voxel, enabling the computation of innovative maps of tissue microstructure. DW-MRI model development has been dominated by brain applications. More recently, advanced methods with high fidelity to histology are gaining momentum in other contexts, for example, in oncological applications of body imaging, where new biomarkers are urgently needed. The objective of this article is to review the state-of-the-art of DW-MRI in body imaging (ie, not including the nervous system) in oncology, and to analyze its value as compared to reference colocalized histology measurements, given that demonstrating the histological validity of any new DW-MRI method is essential. In this article, we review the current landscape of DW-MRI techniques that extend standard apparent diffusion coefficient (ADC), describing their acquisition protocols, signal models, fitting settings, microstructural parameters, and relationship with histology. Preclinical, clinical, and in/ex vivo studies were included. The most used techniques were intravoxel incoherent motion (IVIM; 36.3% of used techniques), diffusion kurtosis imaging (DKI; 16.7%), vascular, extracellular, and restricted diffusion for cytometry in tumors (VERDICT; 13.3%), and imaging microstructural parameters using limited spectrally edited diffusion (IMPULSED; 11.7%). Another notable category of techniques relates to innovative b-tensor diffusion encoding or joint diffusion-relaxometry. The reviewed approaches provide histologically meaningful indices of cancer microstructure (eg, vascularization/cellularity) which, while not necessarily accurate numerically, may still provide useful sensitivity to microscopic pathological processes. Future work of the community should focus on improving the inter-/intra-scanner robustness, and on assessing histological validity in broader contexts. LEVEL OF EVIDENCE: NA TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Ella Fokkinga
- Biomedical Engineering, Track Medical Physics, Delft University of Technology, Delft, The Netherlands
- Radiomics Group, Vall d'Hebron Institute of Oncology, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| | - Juan A Hernandez-Tamames
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Andrada Ianus
- Champalimaud Research, Champalimaud Foundation, Lisbon, Portugal
| | - Markus Nilsson
- Department of Diagnostic Radiology, Clinical Sciences Lund, Lund, Sweden
| | - Chantal M W Tax
- Cardiff University Brain Research Imaging Center (CUBRIC), School of Physics and Astronomy, Cardiff University, Cardiff, United Kingdom
- Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Raquel Perez-Lopez
- Radiomics Group, Vall d'Hebron Institute of Oncology, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| | - Francesco Grussu
- Radiomics Group, Vall d'Hebron Institute of Oncology, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| |
Collapse
|
16
|
Stabinska J, Wittsack HJ, Lerman LO, Ljimani A, Sigmund EE. Probing Renal Microstructure and Function with Advanced Diffusion MRI: Concepts, Applications, Challenges, and Future Directions. J Magn Reson Imaging 2023:10.1002/jmri.29127. [PMID: 37991093 PMCID: PMC11117411 DOI: 10.1002/jmri.29127] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Revised: 10/26/2023] [Accepted: 10/27/2023] [Indexed: 11/23/2023] Open
Abstract
Diffusion measurements in the kidney are affected not only by renal microstructure but also by physiological processes (i.e., glomerular filtration, water reabsorption, and urine formation). Because of the superposition of passive tissue diffusion, blood perfusion, and tubular pre-urine flow, the limitations of the monoexponential apparent diffusion coefficient (ADC) model in assessing pathophysiological changes in renal tissue are becoming apparent and motivate the development of more advanced diffusion-weighted imaging (DWI) variants. These approaches take advantage of the fact that the length scale probed in DWI measurements can be adjusted by experimental parameters, including diffusion-weighting, diffusion gradient directions and diffusion time. This forms the basis by which advanced DWI models can be used to capture not only passive diffusion effects, but also microcirculation, compartmentalization, tissue anisotropy. In this review, we provide a comprehensive overview of the recent advancements in the field of renal DWI. Following a short introduction on renal structure and physiology, we present the key methodological approaches for the acquisition and analysis of renal DWI data, including intravoxel incoherent motion (IVIM), diffusion tensor imaging (DTI), non-Gaussian diffusion, and hybrid IVIM-DTI. We then briefly summarize the applications of these methods in chronic kidney disease and renal allograft dysfunction. Finally, we discuss the challenges and potential avenues for further development of renal DWI. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Julia Stabinska
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Hans-Jörg Wittsack
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Dusseldorf, Germany
| | - Lilach O. Lerman
- Division of Nephrology and Hypertension and Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Alexandra Ljimani
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Dusseldorf, Germany
| | - Eric E. Sigmund
- Bernard and Irene Schwartz Center for Biomedical Imaging Center for Advanced Imaging Innovation and Research (CAI2R), New York University Langone Health, New York City, New York, USA
| |
Collapse
|
17
|
Villa G, Daina E, Brambilla P, Gamba S, Leone VF, Carrara C, Rizzo P, Noris M, Remuzzi G, Remuzzi A, Caroli A. Functional Magnetic Resonance Imaging to Monitor Disease Progression: A Prospective Study in Patients with Primary Membranoproliferative Glomerulonephritis. Nephron Clin Pract 2023; 148:367-378. [PMID: 37926085 PMCID: PMC11151975 DOI: 10.1159/000534893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 10/25/2023] [Indexed: 11/07/2023] Open
Abstract
INTRODUCTION Primary membranoproliferative glomerulonephritis (MPGN) is a rare kidney disease with poor prognosis and no specific therapies. The disease heterogeneity and the difficulty of performing repeated kidney biopsies pose big challenges. This study investigates the correlation between non-contrast enhanced magnetic resonance imaging (MRI) and histologic and clinical findings in patients with primary MPGN. METHODS Patients with primary MPGN underwent baseline and 1-year kidney MRI in addition to biopsy and laboratory testing as part of a prospective MRI subproject of a clinical trial (ClinicalTrials.gov identifier NCT03723512). Diffusion-weighted and phase-contrast MRI were used to investigate kidney diffusivity and perfusion. Peritubular interstitial volume and fibrosis were quantified on kidney biopsies. RESULTS Seven patients with primary MPGN (18[17-21] years, 43% females) were included. Kidney biopsies showed variable degree of global and segmental glomerular sclerosis ([5-30]% and [10-60]%), mild interstitial fibrosis (<10%), and increased peritubular interstitial volume ([19-40]%). MRI and laboratory parameters changed very differently from patient to patient over 1 year. Peritubular interstitial volume and glomerular sclerosis negatively associated with renal blood flow (RBF) (rho = -0.81 and -0.77), and positively with renal vascular resistance (RVR) (rho = 0.65 and 0.73). Urinary albumin to creatinine ratio (uACR) negatively associated with RBF and filtration fraction (FF) (rho = -0.86 and -0.6), while positively with RVR (rho = 0.88). uACR decrease was associated with kidney diffusivity increase (rho = -0.5). Measured glomerular filtration rate (GFR) positively associated with kidney diffusivity, RBF, and FF (rho = 0.87, 0.85, and 0.59), while negatively with RVR (rho = -0.89); GFR increase was associated with kidney diffusivity, RBF, and FF increase (rho = 0.77, 0.7, and 0.7) and RVR decrease (rho = -0.7). CONCLUSION The strong correlation found between MRI and histologic and clinical findings, despite the rather limited number of patients, highlights MRI potential to monitor disease progression in patients with rare kidney disease.
Collapse
Affiliation(s)
- Giulia Villa
- Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy
| | - Erica Daina
- Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy
| | | | - Sara Gamba
- Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy
| | | | - Camillo Carrara
- Unit of Nephrology and Dialysis, ASST Papa Giovanni XXIII, Bergamo, Italy
| | - Paola Rizzo
- Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy
| | - Marina Noris
- Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy
| | - Giuseppe Remuzzi
- Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy
| | - Andrea Remuzzi
- Department of Management, Information and Production Engineering, University of Bergamo, Bergamo, Italy
| | - Anna Caroli
- Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy
| |
Collapse
|
18
|
Friedli I, Baid-Agrawal S, Unwin R, Morell A, Johansson L, Hockings PD. Magnetic Resonance Imaging in Clinical Trials of Diabetic Kidney Disease. J Clin Med 2023; 12:4625. [PMID: 37510740 PMCID: PMC10380287 DOI: 10.3390/jcm12144625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 06/28/2023] [Accepted: 07/04/2023] [Indexed: 07/30/2023] Open
Abstract
Chronic kidney disease (CKD) associated with diabetes mellitus (DM) (known as diabetic kidney disease, DKD) is a serious and growing healthcare problem worldwide. In DM patients, DKD is generally diagnosed based on the presence of albuminuria and a reduced glomerular filtration rate. Diagnosis rarely includes an invasive kidney biopsy, although DKD has some characteristic histological features, and kidney fibrosis and nephron loss cause disease progression that eventually ends in kidney failure. Alternative sensitive and reliable non-invasive biomarkers are needed for DKD (and CKD in general) to improve timely diagnosis and aid disease monitoring without the need for a kidney biopsy. Such biomarkers may also serve as endpoints in clinical trials of new treatments. Non-invasive magnetic resonance imaging (MRI), particularly multiparametric MRI, may achieve these goals. In this article, we review emerging data on MRI techniques and their scientific, clinical, and economic value in DKD/CKD for diagnosis, assessment of disease pathogenesis and progression, and as potential biomarkers for clinical trial use that may also increase our understanding of the efficacy and mode(s) of action of potential DKD therapeutic interventions. We also consider how multi-site MRI studies are conducted and the challenges that should be addressed to increase wider application of MRI in DKD.
Collapse
Affiliation(s)
- Iris Friedli
- Antaros Medical, BioVenture Hub, 43183 Mölndal, Sweden
| | - Seema Baid-Agrawal
- Transplant Center, Sahlgrenska University Hospital, University of Gothenburg, 41345 Gothenburg, Sweden
| | - Robert Unwin
- AstraZeneca R&D BioPharmaceuticals, Translational Science and Experimental Medicine, Early Cardiovascular, Renal & Metabolic Diseases (CVRM), Granta Park, Cambridge CB21 6GH, UK
| | - Arvid Morell
- Antaros Medical, BioVenture Hub, 43183 Mölndal, Sweden
| | | | - Paul D Hockings
- Antaros Medical, BioVenture Hub, 43183 Mölndal, Sweden
- MedTech West, Chalmers University of Technology, 41345 Gothenburg, Sweden
| |
Collapse
|
19
|
Gilani N, Mikheev A, Brinkmann IM, Basukala D, Benkert T, Kumbella M, Babb JS, Chandarana H, Sigmund EE. Characterization of motion dependent magnetic field inhomogeneity for DWI in the kidneys. Magn Reson Imaging 2023; 100:93-101. [PMID: 36924807 PMCID: PMC10108090 DOI: 10.1016/j.mri.2023.03.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 03/10/2023] [Accepted: 03/12/2023] [Indexed: 03/15/2023]
Abstract
PURPOSE Diffusion-weighted imaging (DWI) of the abdomen has increased dramatically for both research and clinical purposes. Motion and static field inhomogeneity related challenges limit image quality of abdominopelvic imaging with the most conventional echo-planar imaging (EPI) pulse sequence. While reversed phase encoded imaging is increasingly used to facilitate distortion correction, it typically assumes one motion independent magnetic field distribution. In this study, we describe a more generalized workflow for the case of kidney DWI in which the field inhomogeneity at multiple respiratory phases is mapped and used to correct all images in a multi-contrast DWI series. METHODS In this HIPAA-compliant and IRB-approved prospective study, 8 volunteers (6 M, ages 28-51) had abdominal imaging performed in a 3 T MRI system (MAGNETOM Prisma; Siemens Healthcare, Erlangen, Germany) with ECG gating. Coronal oblique T2-weighted HASTE images were collected for anatomical reference. Sagittal phase-contrast (PC) MRI images through the left renal artery were collected to determine systolic and diastolic phases. Cardiac triggered oblique coronal DWI were collected at 10 b-values between 0 and 800 s/mm2 and 12 directions. DWI series were distortion corrected using field maps generated by forward and reversed phase encoded b = 0 images collected over the full respiratory cycle and matched by respiratory phase. Morphologic accuracy, intraseries spatial variability, and diffusion tensor imaging (DTI) metrics mean diffusivity (MD) and fractional anisotropy (FA) were compared for results generated with no distortion correction, correction with only one respiratory bin, and correction with multiple respiratory bins across the breathing cycle. RESULTS Computed field maps showed significant variation in static field with kidney laterality, region, and respiratory phase. Distortion corrected images showed significantly better registration to morphologic images than uncorrected images; for the left kidney, the multiple bin correction outperformed one bin correction. Line profile analysis showed significantly reduced spatial variation with multiple bins than one bin correction. DTI metrics were mostly similar between correction methods, with some differences observed in MD between uncorrected and corrected datasets. CONCLUSIONS Our results indicate improved morphology of kidney DWI and derived parametric maps as well as reduced variability over the full image series using the motion-resolved distortion correction. This work highlights some morphologic and quantitative metric improvements can be obtained for kidney DWI when distortion correction is performed in a respiratory-resolved manner.
Collapse
Affiliation(s)
- Nima Gilani
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA.
| | - Artem Mikheev
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA
| | | | - Dibash Basukala
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA
| | | | - Malika Kumbella
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA
| | - James S Babb
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA
| | - Hersh Chandarana
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA
| | - Eric E Sigmund
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA.
| |
Collapse
|
20
|
Chen Y, Yang P, Fu C, Bian Y, Shao C, Ma C, Lu J. Variabilities in apparent diffusion coefficient (ADC) measurements of the spleen and the paraspinal muscle: A single center large cohort study. Heliyon 2023; 9:e18166. [PMID: 37519768 PMCID: PMC10372245 DOI: 10.1016/j.heliyon.2023.e18166] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 07/08/2023] [Accepted: 07/10/2023] [Indexed: 08/01/2023] Open
Abstract
Purpose Evaluation of the variabilities in apparent diffusion coefficient (ADC) measurements of the spleen (ADCspleen) and the paraspinal muscles (ADCmuscle) to identify the reference organ for normalizing the ADC from the abdominal diffusion weighted imaging (DWI). Methods Two MRI scanners, with 314 abdominal exams on the GE and 929 on the Siemens system, were used for MRI examinations including DWI (b-values, 50 and 800 s/mm2). For a subset of 73 exams on the Siemens system a second exam was conducted. Four regions of interest (ROIs) in each exam were placed to measure the ADCspleen and the bilateral ADCmuscle. ADC variability between patients (on each scanner separately), ADC variability due to ROI placement between the two ROIs in each organ, and variability in the subset between the first and second exams were assessed. Results The ADCspleen was more scattered and variable than the ADCmuscle in the comparability (n = 929 and 314 for two MRI scanners, respectively) and repeatability (n = 73) datasets. The Bland-Altmann bias and limits of agreement (LoAs) for the ADCspleen (ICC, 0.47; CV, 0.070) and ADCmuscle (ICC, 0.67; CV, 0.023) in the repeatability datasets (n = 73) were -0.1 (-25.7%-25.6%) and -0.3 (-8.8%-8.1%), respectively. For the Siemens system, the Bland-Altmann bias and LoAs for the ADCspleen (ICC, 0.72; CV, 0.061) and ADCmuscle (ICC, 0.53; CV, 0.030) in the comparability datasets (n = 929) were 2.1 (-20.0%-24.2%) and 0.7 (-10.0%-11.4%), respectively. Similar findings have been found in the GE system (n = 314). The CVs for the ADCmuscle measurements were lower than those of the ADCspleen both in the repeatability and the comparability analyses (all p < 0.001). Conclusion Paraspinal muscles demonstrate better reference characteristics than the spleen in estimating ADC variability of abdominal DWI.
Collapse
Affiliation(s)
- Yukun Chen
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, Shanghai, 200433, China
| | - Panpan Yang
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, Shanghai, 200433, China
| | - Caixia Fu
- Application Developments, Siemens Shenzhen Magnetic Resonance Ltd., Siemens Healthineers, Shenzhen, 518057, China
| | - Yun Bian
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, Shanghai, 200433, China
| | - Chengwei Shao
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, Shanghai, 200433, China
| | - Chao Ma
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, Shanghai, 200433, China
- College of Electronic and Information Engineering, Tongji University, Shanghai, 201804, China
| | - Jianping Lu
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, Shanghai, 200433, China
| |
Collapse
|
21
|
Sigmund EE, Mikheev A, Brinkmann IM, Gilani N, Babb JS, Basukala D, Benkert T, Veraart J, Chandarana H. Cardiac Phase and Flow Compensation Effects on REnal Flow and Microstructure AnisotroPy MRI in Healthy Human Kidney. J Magn Reson Imaging 2023; 58:210-220. [PMID: 36399101 PMCID: PMC10192459 DOI: 10.1002/jmri.28517] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 10/20/2022] [Accepted: 10/21/2022] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Renal diffusion-weighted imaging (DWI) involves microstructure and microcirculation, quantified with diffusion tensor imaging (DTI), intravoxel incoherent motion (IVIM), and hybrid models. A better understanding of their contrast may increase specificity. PURPOSE To measure modulation of DWI with cardiac phase and flow-compensated (FC) diffusion gradient waveforms. STUDY TYPE Prospective. POPULATION Six healthy volunteers (ages: 22-48 years, five females), water phantom. FIELD STRENGTH/SEQUENCE 3-T, prototype DWI sequence with 2D echo-planar imaging, and bipolar (BP) or FC gradients. 2D Half-Fourier Single-shot Turbo-spin-Echo (HASTE). Multiple-phase 2D spoiled gradient-echo phase contrast (PC) MRI. ASSESSMENT BP and FC water signal decays were qualitatively compared. Renal arteries and velocities were visualized on PC-MRI. Systolic (peak velocity), diastolic (end stable velocity), and pre-systolic (before peak velocity) phases were identified. Following mutual information-based retrospective self-registration of DWI within each kidney, and Marchenko-Pastur Principal Component Analysis (MPPCA) denoising, combined IVIM-DTI analysis estimated mean diffusivity (MD), fractional anisotropy (FA), and eigenvalues (λi) from tissue diffusivity (Dt ), perfusion fraction (fp ), and pseudodiffusivity (Dp , Dp,axial , Dp,radial ), for each tissue (cortex/medulla, segmented on b0/FA respectively), phase, and waveform (BP, FC). Monte Carlo water diffusion simulations aided data interpretation. STATISTICAL TESTS Mixed model regression probed differences between tissue types and pulse sequences. Univariate general linear model analysis probed variations among cardiac phases. Spearman correlations were measured between diffusion metrics and renal artery velocities. Statistical significance level was set at P < 0.05. RESULTS Water BP and FC signal decays showed no differences. Significant pulse sequence dependence occurred for λ1 , λ3 , FA, Dp , fp , Dp,axial , Dp,radial in cortex and medulla, and medullary λ2 . Significant cortex/medulla differences occurred with BP for all metrics except MD (systole [P = 0.224]; diastole [P = 0.556]). Significant phase dependence occurred for Dp , Dp,axial , Dp,radial for BP and medullary λ1 , λ2 , λ3 , MD for FC. FA correlated significantly with velocity. Monte Carlo simulations indicated medullary measurements were consistent with a 34 μm tubule diameter. DATA CONCLUSION Cardiac gating and flow compensation modulate of measurements of renal diffusion. EVIDENCE LEVEL 2 TECHNICAL EFFICACY STAGE: 2.
Collapse
Affiliation(s)
- Eric E Sigmund
- Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | - Artem Mikheev
- Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | | | - Nima Gilani
- Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | - James S Babb
- Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | - Dibash Basukala
- Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | - Thomas Benkert
- Siemens Medical Solutions USA Inc., Malvern, Pennsylvania, USA
| | - Jelle Veraart
- Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | - Hersh Chandarana
- Center for Advanced Imaging and Innovation (CAI2R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| |
Collapse
|
22
|
Chen J, Zhang Z, Liu J, Li C, Yin M, Nie L, Song B. Multiparametric Magnetic Resonance Imaging of the Kidneys: Effects of Regional, Side, and Hydration Variations on Functional Quantifications. J Magn Reson Imaging 2023; 57:1576-1586. [PMID: 36219465 PMCID: PMC10079549 DOI: 10.1002/jmri.28477] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 09/28/2022] [Accepted: 09/29/2022] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND To standardize renal functional magnetic resonance imaging (MRI), it is important to understand the influence of side-to-side variation, regional variation within the organ, and hydration states in MRI and to search for variables that are not affected by those variations. PURPOSE To assess MRI-based biomarkers for characterizing the kidney in healthy volunteers while considering variations in anatomic factors and hydration states. STUDY TYPE Prospective. SUBJECTS Twenty-five healthy volunteers (15 females and 10 males, median age 25 years). FIELD STRENGTH/SEQUENCE 3.0 T intravoxel incoherent motion diffusion-weighted imaging, arterial spinning labeling imaging, blood oxygenation level dependent imaging, and three-dimensional MR elastography. ASSESSMENT Functional variables were measured before and after water challenge. Regions of interest were manually drawn by two investigators (JC and ZZ, with 8- and 5-year experiences in abdominal radiology) in the cortex, the medulla, and the entire kidney. The medulla/cortex ratio was calculated. STATISTICAL TESTS Paired t-test or Wilcoxon signed rank test; interobserver correlation coefficient; repeatability coefficients; Spearman's correlation; significance level: P < 0.05. RESULTS Diffusion parameters were only subject to regional variation. R2*, RBF, and renal stiffness (RS) showed regional variation, side variation, and dependence on hydration states. For each side and hydration state, the cortex showed significantly higher standard apparent diffusion coefficient (sADC), higher true diffusion (D), lower R2*, and lower RS than the medulla. For each region at baseline, the left kidney showed significantly higher R2*, higher RS, and lower renal blood flow (RBF) than the right kidney. For each region and side, RS and RBF increased significantly while R2* decreased significantly after water intake. After introducing the intrinsic regional difference, significantly higher medulla/cortex ratio of RS remained after water intake except for RS@90 Hz in the right kidney. DATA CONCLUSION Renal multiparametric MRI quantifications were affected by regional variation, side variation, and hydration states. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Jie Chen
- Department of Radiology, Sichuan University West China Hospital, Chengdu, China
| | - Zhen Zhang
- Department of Radiology, Sichuan University West China Hospital, Chengdu, China
| | - Juan Liu
- Department of Radiology, Sichuan University West China Hospital, Chengdu, China
| | - Chengjie Li
- Department of Radiology, Chongqing Southeast Hospital, Chongqing, China
| | - Meng Yin
- Department of Radiology, Mayo Clinic, USA
| | - Lisha Nie
- GE Healthcare, MR Research China, Beijing, China
| | - Bin Song
- Department of Radiology, Sichuan University West China Hospital, Chengdu, China
- Department of Radiology, Sanya People’s Hospital, Sanya, China
| |
Collapse
|
23
|
Laothamatas I, Al Mubarak H, Reddy A, Wax R, Badani K, Taouli B, Bane O, Lewis S. Multiparametric MRI of Solid Renal Masses: Principles and Applications of Advanced Quantitative and Functional Methods for Tumor Diagnosis and Characterization. J Magn Reson Imaging 2023. [PMID: 37052601 DOI: 10.1002/jmri.28718] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/23/2023] [Accepted: 03/23/2023] [Indexed: 04/14/2023] Open
Abstract
Solid renal masses (SRMs) are increasingly detected and encompass both benign and malignant masses, with renal cell carcinoma (RCC) being the most common malignant SRM. Most patients with SRMs will undergo management without a priori pathologic confirmation. There is an unmet need to noninvasively diagnose and characterize RCCs, as significant variability in clinical behavior is observed and a wide range of differing management options exist. Cross-sectional imaging modalities, including magnetic resonance imaging (MRI), are increasingly used for SRM characterization. Multiparametric (mp) MRI techniques can provide insight into tumor biology by probing different physiologic/pathophysiologic processes noninvasively. These include sequences that probe tissue microstructure, including intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) and T1 relaxometry; oxygen metabolism (blood oxygen level dependent [BOLD-MRI]); as well as vascular flow and perfusion (dynamic contrast-enhanced MRI [DCE-MRI] and arterial spin labeling [ASL]). In this review, we will discuss each mpMRI method in terms of its principles, roles, and discuss the results of human studies for SRM assessment. Future validation of these methods may help to enable a personalized management approach for patients with SRM in the emerging era of precision medicine. EVIDENCE LEVEL: 5. TECHNICAL EFFICACY: 2.
Collapse
Affiliation(s)
- Indira Laothamatas
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Haitham Al Mubarak
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Arthi Reddy
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Rebecca Wax
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Ketan Badani
- Department of Urology, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Bachir Taouli
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Octavia Bane
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Sara Lewis
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| |
Collapse
|
24
|
Echeverria‐Chasco R, Martin‐Moreno PL, Garcia‐Fernandez N, Vidorreta M, Aramendia‐Vidaurreta V, Cano D, Villanueva A, Bastarrika G, Fernández‐Seara MA. Multiparametric renal magnetic resonance imaging: A reproducibility study in renal allografts with stable function. NMR IN BIOMEDICINE 2023; 36:e4832. [PMID: 36115029 PMCID: PMC10078573 DOI: 10.1002/nbm.4832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 09/13/2022] [Accepted: 09/15/2022] [Indexed: 06/15/2023]
Abstract
Monitoring renal allograft function after transplantation is key for the early detection of allograft impairment, which in turn can contribute to preventing the loss of the allograft. Multiparametric renal MRI (mpMRI) is a promising noninvasive technique to assess and characterize renal physiopathology; however, few studies have employed mpMRI in renal allografts with stable function (maintained function over a long time period). The purposes of the current study were to evaluate the reproducibility of mpMRI in transplant patients and to characterize normal values of the measured parameters, and to estimate the labeling efficiency of Pseudo-Continuous Arterial Spin Labeling (PCASL) in the infrarenal aorta using numerical simulations considering experimental measurements of aortic blood flow profiles. The subjects were 20 transplant patients with stable kidney function, maintained over 1 year. The MRI protocol consisted of PCASL, intravoxel incoherent motion, and T1 inversion recovery. Phase contrast was used to measure aortic blood flow. Renal blood flow (RBF), diffusion coefficient (D), pseudo-diffusion coefficient (D*), flowing fraction ( f ), and T1 maps were calculated and mean values were measured in the cortex and medulla. The labeling efficiency of PCASL was estimated from simulation of Bloch equations. Reproducibility was assessed with the within-subject coefficient of variation, intraclass correlation coefficient, and Bland-Altman analysis. Correlations were evaluated using the Pearson correlation coefficient. The significance level was p less than 0.05. Cortical reproducibility was very good for T1, D, and RBF, moderate for f , and low for D*, while medullary reproducibility was good for T1 and D. Significant correlations in the cortex between RBF and f (r = 0.66), RBF and eGFR (r = 0.64), and D* and eGFR (r = -0.57) were found. Normal values of the measured parameters employing the mpMRI protocol in kidney transplant patients with stable function were characterized and the results showed good reproducibility of the techniques.
Collapse
Affiliation(s)
- Rebeca Echeverria‐Chasco
- Department of RadiologyClínica Universidad de NavarraPamplonaSpain
- IdiSNA, Instituto de Investigación Sanitaria de NavarraPamplonaSpain
| | - Paloma L. Martin‐Moreno
- IdiSNA, Instituto de Investigación Sanitaria de NavarraPamplonaSpain
- Department of NephrologyClínica Universidad de NavarraPamplonaSpain
| | - Nuria Garcia‐Fernandez
- IdiSNA, Instituto de Investigación Sanitaria de NavarraPamplonaSpain
- Department of NephrologyClínica Universidad de NavarraPamplonaSpain
| | | | - Verónica Aramendia‐Vidaurreta
- Department of RadiologyClínica Universidad de NavarraPamplonaSpain
- IdiSNA, Instituto de Investigación Sanitaria de NavarraPamplonaSpain
| | - David Cano
- Department of RadiologyClínica Universidad de NavarraPamplonaSpain
| | - Arantxa Villanueva
- IdiSNA, Instituto de Investigación Sanitaria de NavarraPamplonaSpain
- Electrical Electronics and Communications Engineering Department and Smart Cities InstitutePublic University of NavarrePamplonaSpain
| | - Gorka Bastarrika
- Department of RadiologyClínica Universidad de NavarraPamplonaSpain
- IdiSNA, Instituto de Investigación Sanitaria de NavarraPamplonaSpain
| | - Maria A. Fernández‐Seara
- Department of RadiologyClínica Universidad de NavarraPamplonaSpain
- IdiSNA, Instituto de Investigación Sanitaria de NavarraPamplonaSpain
| |
Collapse
|
25
|
Wang J, Ma C, Yang P, Wang Z, Chen Y, Bian Y, Shao C, Lu J. Diffusion-Weighted Imaging of the Abdomen: Correction for Gradient Nonlinearity Bias in Apparent Diffusion Coefficient. J Magn Reson Imaging 2022. [PMID: 36373955 DOI: 10.1002/jmri.28529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 10/31/2022] [Accepted: 11/01/2022] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Gradient nonlinearity (GNL) introduces spatial nonuniformity bias in apparent diffusion coefficient (ADC) measurements, especially at large offsets from the magnet isocenter. PURPOSE To investigate the effects of GNL in abdominal ADC measurements and to develop an ADC bias correction procedure. STUDY TYPE Retrospective. PHANTOM/POPULATION Two homemade ultrapure water phantoms/25 patients with histologically confirmed pancreatic ductal adenocarcinoma (PDAC). FIELD STRENGTH/SEQUENCE A 3.0 T/diffusion-weighted imaging (DWI) with single-shot echo-planar imaging sequence. ASSESSMENT ADC bias was computed in the three orthogonal directions at different offset locations. The spatial-dependent correctors of ADC bias were generated from the ADCs of phantom 1. The ADCs were estimated before and after corrections for the phantom 1 with both the proposed approach and the theoretical GNL correction method. For the patients, ADCs were measured in abdominal tissues including left and right liver lobes, PDAC, spleen, bilateral kidneys, and bilateral paraspinal muscles. STATISTICAL TEST Friedman tests and Wilcoxon tests. RESULTS The ADC bias measured by phantom 1 was 9.7% and 12.6% higher in the right-left and anterior-posterior directions and 9.2% lower in the superior-inferior direction at the 150 mm offsets from the magnetic isocenter. The corrected vs. the uncorrected ADCs measurements (median: 2.20 × 10-3 mm2 /sec for both the proposed method and the theoretical GNL method vs. 2.31 × 10-3 mm2 /sec, respectively) and their relative ADC errors (0.014, 0.016, and 0.054, respectively) were lower in the phantom 1. The relative ADC errors substantially decreased after correction in the phantom 2 (median: 0.048 and -0.008, respectively). The ADCs of all the abdominal tissues were lower after correction except for the left liver lobes (P = 0.13). DATA CONCLUSION GNL bias in abdominal ADC can be measured by a DWI phantom. The proposed correction procedure was successfully applied for the bias correction in abdominal ADC. EVIDENCE LEVEL 3. TECHNICAL EFFICACY Stage 1.
Collapse
Affiliation(s)
- Jian Wang
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, China
| | - Chao Ma
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, China.,College of Electronic and Information Engineering, Tongji University, Shanghai, China
| | - Panpan Yang
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, China
| | - Zhen Wang
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, China
| | - Yufei Chen
- College of Electronic and Information Engineering, Tongji University, Shanghai, China
| | - Yun Bian
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, China
| | - Chengwei Shao
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, China
| | - Jianping Lu
- Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, China
| |
Collapse
|
26
|
deSouza NM, van der Lugt A, Deroose CM, Alberich-Bayarri A, Bidaut L, Fournier L, Costaridou L, Oprea-Lager DE, Kotter E, Smits M, Mayerhoefer ME, Boellaard R, Caroli A, de Geus-Oei LF, Kunz WG, Oei EH, Lecouvet F, Franca M, Loewe C, Lopci E, Caramella C, Persson A, Golay X, Dewey M, O'Connor JPB, deGraaf P, Gatidis S, Zahlmann G. Standardised lesion segmentation for imaging biomarker quantitation: a consensus recommendation from ESR and EORTC. Insights Imaging 2022; 13:159. [PMID: 36194301 PMCID: PMC9532485 DOI: 10.1186/s13244-022-01287-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 08/01/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Lesion/tissue segmentation on digital medical images enables biomarker extraction, image-guided therapy delivery, treatment response measurement, and training/validation for developing artificial intelligence algorithms and workflows. To ensure data reproducibility, criteria for standardised segmentation are critical but currently unavailable. METHODS A modified Delphi process initiated by the European Imaging Biomarker Alliance (EIBALL) of the European Society of Radiology (ESR) and the European Organisation for Research and Treatment of Cancer (EORTC) Imaging Group was undertaken. Three multidisciplinary task forces addressed modality and image acquisition, segmentation methodology itself, and standards and logistics. Devised survey questions were fed via a facilitator to expert participants. The 58 respondents to Round 1 were invited to participate in Rounds 2-4. Subsequent rounds were informed by responses of previous rounds. RESULTS/CONCLUSIONS Items with ≥ 75% consensus are considered a recommendation. These include system performance certification, thresholds for image signal-to-noise, contrast-to-noise and tumour-to-background ratios, spatial resolution, and artefact levels. Direct, iterative, and machine or deep learning reconstruction methods, use of a mixture of CE marked and verified research tools were agreed and use of specified reference standards and validation processes considered essential. Operator training and refreshment were considered mandatory for clinical trials and clinical research. Items with a 60-74% agreement require reporting (site-specific accreditation for clinical research, minimal pixel number within lesion segmented, use of post-reconstruction algorithms, operator training refreshment for clinical practice). Items with ≤ 60% agreement are outside current recommendations for segmentation (frequency of system performance tests, use of only CE-marked tools, board certification of operators, frequency of operator refresher training). Recommendations by anatomical area are also specified.
Collapse
Affiliation(s)
- Nandita M deSouza
- Division of Radiotherapy and Imaging, The Institute of Cancer Research and Royal Marsden NHS Foundation Trust, London, UK.
| | - Aad van der Lugt
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - Christophe M Deroose
- Nuclear Medicine, University Hospitals Leuven, Leuven, Belgium.,Nuclear Medicine and Molecular Imaging, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
| | | | - Luc Bidaut
- College of Science, University of Lincoln, Lincoln, Lincoln, LN6 7TS, UK
| | - Laure Fournier
- INSERM, Radiology Department, AP-HP, Hopital Europeen Georges Pompidou, Université de Paris, PARCC, 75015, Paris, France
| | - Lena Costaridou
- School of Medicine, University of Patras, University Campus, Rio, 26 500, Patras, Greece
| | - Daniela E Oprea-Lager
- Department of Radiology and Nuclear Medicine, Amsterdam, UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Elmar Kotter
- Department of Radiology, University Medical Center Freiburg, Freiburg, Germany
| | - Marion Smits
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - Marius E Mayerhoefer
- Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.,Memorial Sloan Kettering Cancer Centre, New York, NY, USA
| | - Ronald Boellaard
- Department of Radiology and Nuclear Medicine, Amsterdam, UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Anna Caroli
- Department of Biomedical Engineering, Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy
| | - Lioe-Fee de Geus-Oei
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.,Biomedical Photonic Imaging Group, University of Twente, Enschede, The Netherlands
| | - Wolfgang G Kunz
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Edwin H Oei
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - Frederic Lecouvet
- Department of Radiology, Institut de Recherche Expérimentale et Clinique (IREC), Cliniques Universitaires Saint Luc, Université Catholique de Louvain (UCLouvain), 10 Avenue Hippocrate, 1200, Brussels, Belgium
| | - Manuela Franca
- Department of Radiology, Centro Hospitalar Universitário do Porto, Instituto de Ciências Biomédicas de Abel Salazar, University of Porto, Porto, Portugal
| | - Christian Loewe
- Division of Cardiovascular and Interventional Radiology, Department for Bioimaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Egesta Lopci
- Nuclear Medicine, IRCCS - Humanitas Research Hospital, via Manzoni 56, Rozzano, MI, Italy
| | - Caroline Caramella
- Radiology Department, Hôpital Marie Lannelongue, Institut d'Oncologie Thoracique, Université Paris-Saclay, Le Plessis-Robinson, France
| | - Anders Persson
- Department of Radiology, and Department of Health, Medicine and Caring Sciences, Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Xavier Golay
- Queen Square Institute of Neurology, University College London, London, UK
| | - Marc Dewey
- Department of Radiology, Charité Universitätsmedizin Berlin, Berlin, Germany
| | - James P B O'Connor
- Division of Radiotherapy and Imaging, The Institute of Cancer Research and Royal Marsden NHS Foundation Trust, London, UK
| | - Pim deGraaf
- Department of Radiology and Nuclear Medicine, Amsterdam, UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Sergios Gatidis
- Department of Radiology, University of Tubingen, Tübingen, Germany
| | - Gudrun Zahlmann
- Radiological Society of North America (RSNA), Oak Brook, IL, USA
| | | | | |
Collapse
|
27
|
McTavish S, Van AT, Peeters JM, Weiss K, Makowski MR, Braren RF, Karampinos DC. Motion compensated renal diffusion weighted imaging. Magn Reson Med 2022; 89:144-160. [PMID: 36098347 DOI: 10.1002/mrm.29433] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 07/15/2022] [Accepted: 08/10/2022] [Indexed: 11/09/2022]
Abstract
PURPOSE To assess the effect of respiratory motion and cardiac driven pulsation in renal DWI and to examine asymmetrical velocity-compensated diffusion encoding waveforms for robust ADC mapping in the kidneys. METHODS The standard monopolar Stejskal-Tanner pulsed gradient spin echo (pgse) and the asymmetric bipolar velocity-compensated (asym-vc) diffusion encoding waveforms were used for coronal renal DWI at 3T. The robustness of the ADC quantification in the kidneys was tested with the aforementioned waveforms in respiratory-triggered and breath-held cardiac-triggered scans at different trigger delays in 10 healthy subjects. RESULTS The pgse waveform showed higher ADC values in the right kidney at short trigger delays in comparison to longer trigger delays in the respiratory triggered scans when the diffusion gradient was applied in the feet-head (FH) direction. The coefficient of variation over all respiratory trigger delays, averaged over all subjects was 0.15 for the pgse waveform in the right kidney when diffusion was measured in the FH direction; the corresponding coefficient of variation for the asym-vc waveform was 0.06. The effect of cardiac driven pulsation was found to be small in comparison to the effect of respiratory motion. CONCLUSION Short trigger delays in respiratory-triggered scans can cause higher ADC values in comparison to longer trigger delays in renal DWI, especially in the right kidney when diffusion is measured in the FH direction. The asym-vc waveform can reduce ADC variation due to respiratory motion in respiratory-triggered scans at the cost of reduced SNR compared to the pgse waveform.
Collapse
Affiliation(s)
- Sean McTavish
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Munich, Germany
| | - Anh T Van
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Munich, Germany
| | | | | | - Marcus R Makowski
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Munich, Germany
| | - Rickmer F Braren
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Munich, Germany
| | - Dimitrios C Karampinos
- Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Munich, Germany
| |
Collapse
|
28
|
Hubbard Cristinacce PL, Keaveney S, Aboagye EO, Hall MG, Little RA, O'Connor JPB, Parker GJM, Waterton JC, Winfield JM, Jauregui-Osoro M. Clinical translation of quantitative magnetic resonance imaging biomarkers - An overview and gap analysis of current practice. Phys Med 2022; 101:165-182. [PMID: 36055125 DOI: 10.1016/j.ejmp.2022.08.015] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 08/05/2022] [Accepted: 08/17/2022] [Indexed: 10/14/2022] Open
Abstract
PURPOSE This overview of the current landscape of quantitative magnetic resonance imaging biomarkers (qMR IBs) aims to support the standardisation of academic IBs to assist their translation to clinical practice. METHODS We used three complementary approaches to investigate qMR IB use and quality management practices within the UK: 1) a literature search of qMR and quality management terms during 2011-2015 and 2016-2020; 2) a database search for clinical research studies using qMR IBs during 2016-2020; and 3) a survey to ascertain the current availability and quality management practices for clinical MRI scanners and associated equipment at research institutions across the UK. RESULTS The analysis showed increased use of all qMR methods between the periods 2011-2015 and 2016-2020 and diffusion-tensor MRI and volumetry to be popular methods. However, the "translation ratio" of journal articles to clinical research studies was higher for qMR methods that have evidence of clinical translation via a commercial route, such as fat fraction and T2 mapping. The number of journal articles citing quality management terms doubled between the periods 2011-2015 and 2016-2020; although, its proportion relative to all journal articles only increased by 3.0%. The survey suggested that quality assurance (QA) and quality control (QC) of data acquisition procedures are under-reported in the literature and that QA/QC of acquired data/data analysis are under-developed and lack consistency between institutions. CONCLUSIONS We summarise current attempts to standardise and translate qMR IBs, and conclude by outlining the ideal quality management practices and providing a gap analysis between current practice and a metrological standard.
Collapse
Affiliation(s)
| | - Sam Keaveney
- MRI Unit, Royal Marsden NHS Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT, UK; Division of Radiotherapy and Imaging, The Institute of Cancer Research, 123 Old Brompton Road, London SW7 3RP, UK
| | - Eric O Aboagye
- Department of Surgery & Cancer, Division of Cancer, Imperial College London, W12 0NN London, UK
| | - Matt G Hall
- National Physical Laboratory, Hampton Road, Teddington TW11 0LW, UK
| | - Ross A Little
- Division of Cancer Sciences, The University of Manchester, Manchester M13 9PT, UK
| | - James P B O'Connor
- Division of Cancer Sciences, The University of Manchester, Manchester M13 9PT, UK; Division of Radiotherapy and Imaging, The Institute of Cancer Research, 123 Old Brompton Road, London SW7 3RP, UK
| | - Geoff J M Parker
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, 90 High Holborn, London WC1V 6LJ, UK; Bioxydyn Ltd, Manchester M15 6SZ, UK
| | - John C Waterton
- Bioxydyn Ltd, Manchester M15 6SZ, UK; Division of Informatics, Imaging and Data Sciences, The University of Manchester, Manchester M13 9PT, UK
| | - Jessica M Winfield
- MRI Unit, Royal Marsden NHS Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT, UK; Division of Radiotherapy and Imaging, The Institute of Cancer Research, 123 Old Brompton Road, London SW7 3RP, UK
| | - Maite Jauregui-Osoro
- Department of Surgery & Cancer, Division of Cancer, Imperial College London, W12 0NN London, UK
| |
Collapse
|
29
|
Caroli A. Diffusion-Weighted Magnetic Resonance Imaging: Clinical Potential and Applications. J Clin Med 2022; 11:3339. [PMID: 35743409 PMCID: PMC9224775 DOI: 10.3390/jcm11123339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Accepted: 06/09/2022] [Indexed: 02/05/2023] Open
Abstract
Since its discovery in the 1980s [...].
Collapse
Affiliation(s)
- Anna Caroli
- Bioengineering Department, Istituto di Ricerche Farmacologiche Mario Negri IRCCS, 24020 Ranica, BG, Italy
| |
Collapse
|
30
|
Stabinska J, Müller-Lutz A, Wittsack HJ, Tell C, Rump LC, Ertas N, Antoch G, Ljimani A. Two point Dixon-based chemical exchange saturation transfer (CEST) MRI in renal transplant patients on 3 T. Magn Reson Imaging 2022; 90:61-69. [PMID: 35476934 DOI: 10.1016/j.mri.2022.04.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 03/30/2022] [Accepted: 04/21/2022] [Indexed: 11/26/2022]
Abstract
PURPOSE To assess the performance of two point (2-pt) Dixon-based chemical exchange saturation transfer (CEST) imaging for fat suppression in renal transplant patients. METHODS The 2-pt Dixon-based CEST MRI was validated in an egg-phantom and in fourteen renal transplant recipients (5 females and 9 males; age range: 23-78 years; mean age: 51 ± 16.8). All CEST experiments were performed on a 3 T clinical MRI scanner using a dual-echo CEST sequence. The 2-pt Dixon technique was applied to generate water-only CEST images at different frequency offsets, which were further used to calculate the z-spectra. The magnetization transfer ratio asymmetry (MTRasym) values in the frequency ranges of hydroxyl, amine and amide protons were estimated in the renal cortex and medulla. RESULTS Results of the in vitro experiments suggest that the 2-pt Dixon technique enables effective fat peak removal and does not introduce additional asymmetries to the z-spectrum. Accordingly, our results in vivo show that the fat-corrected amide proton transfer (APT) effect in the kidney is significantly higher compared to that obtained from the CEST data acquired close to the in-phase condition both in the renal cortex (-0.1 [0.7] vs. -0.7 [1.2], P = 0.029) and medulla (0.3 [0.8] vs. 0.01 [1.3], P = 0.049), indicating that the 2-pt Dixon-based CEST method increases the specificity of the APT contrast by correcting the fat-induced artifacts. CONCLUSION Combination of the dual-echo CEST acquisition with Dixon post-processing provides effective water-fat separation, allowing more accurate quantification of the APT CEST effect in the transplanted kidney.
Collapse
Affiliation(s)
- Julia Stabinska
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Moorenstr. 5, 40225 Düsseldorf, Germany.
| | - Anja Müller-Lutz
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Moorenstr. 5, 40225 Düsseldorf, Germany.
| | - Hans-Jörg Wittsack
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Moorenstr. 5, 40225 Düsseldorf, Germany.
| | - Christian Tell
- Department of Nephrology, Medical Faculty, Medical Faculty, Heinrich Heine University Düsseldorf, Moorenstr. 5, 40225 Düsseldorf, Germany.
| | - Lars Christian Rump
- Department of Nephrology, Medical Faculty, Medical Faculty, Heinrich Heine University Düsseldorf, Moorenstr. 5, 40225 Düsseldorf, Germany.
| | - Neslihan Ertas
- Department of Vascular and Endovascular Surgery, Medical Faculty, Heinrich Heine University Düsseldorf, Moorenstr. 5, 40225 Düsseldorf, Germany.
| | - Gerald Antoch
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Moorenstr. 5, 40225 Düsseldorf, Germany.
| | - Alexandra Ljimani
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Moorenstr. 5, 40225 Düsseldorf, Germany.
| |
Collapse
|
31
|
Englund EK, Reiter DA, Shahidi B, Sigmund EE. Intravoxel Incoherent Motion Magnetic Resonance Imaging in Skeletal Muscle: Review and Future Directions. J Magn Reson Imaging 2022; 55:988-1012. [PMID: 34390617 PMCID: PMC8841570 DOI: 10.1002/jmri.27875] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 07/23/2021] [Accepted: 07/26/2021] [Indexed: 12/29/2022] Open
Abstract
Throughout the body, muscle structure and function can be interrogated using a variety of noninvasive magnetic resonance imaging (MRI) methods. Recently, intravoxel incoherent motion (IVIM) MRI has gained momentum as a method to evaluate components of blood flow and tissue diffusion simultaneously. Much of the prior research has focused on highly vascularized organs, including the brain, kidney, and liver. Unique aspects of skeletal muscle, including the relatively low perfusion at rest and large dynamic range of perfusion between resting and maximal hyperemic states, may influence the acquisition, postprocessing, and interpretation of IVIM data. Here, we introduce several of those unique features of skeletal muscle; review existing studies of IVIM in skeletal muscle at rest, in response to exercise, and in disease states; and consider possible confounds that should be addressed for muscle-specific evaluations. Most studies used segmented nonlinear least squares fitting with a b-value threshold of 200 sec/mm2 to obtain IVIM parameters of perfusion fraction (f), pseudo-diffusion coefficient (D*), and diffusion coefficient (D). In healthy individuals, across all muscles, the average ± standard deviation of D was 1.46 ± 0.30 × 10-3 mm2 /sec, D* was 29.7 ± 38.1 × 10-3 mm2 /sec, and f was 11.1 ± 6.7%. Comparisons of reported IVIM parameters in muscles of the back, thigh, and leg of healthy individuals showed no significant difference between anatomic locations. Throughout the body, exercise elicited a positive change of all IVIM parameters. Future directions including advanced postprocessing models and potential sequence modifications are discussed. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Erin K. Englund
- Department of Radiology, University of Colorado Anschutz Medical Campus
| | | | | | - Eric E. Sigmund
- Department of Radiology, New York University Grossman School of Medicine, NYU Langone Health
- Center for Advanced Imaging and Innovation (CAIR), Bernard and Irene Schwarz Center for Biomedical Imaging (CBI), NYU Langone Health
| |
Collapse
|
32
|
Diffusion-Weighted MRI in the Genitourinary System. J Clin Med 2022; 11:jcm11071921. [PMID: 35407528 PMCID: PMC9000195 DOI: 10.3390/jcm11071921] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Revised: 03/25/2022] [Accepted: 03/28/2022] [Indexed: 12/12/2022] Open
Abstract
Diffusion weighted imaging (DWI) constitutes a major functional parameter performed in Magnetic Resonance Imaging (MRI). The DW sequence is performed by acquiring a set of native images described by their b-values, each b-value representing the strength of the diffusion MR gradients specific to that sequence. By fitting the data with models describing the motion of water in tissue, an apparent diffusion coefficient (ADC) map is built and allows the assessment of water mobility inside the tissue. The high cellularity of tumors restricts the water diffusion and decreases the value of ADC within tumors, which makes them appear hypointense on ADC maps. The role of this sequence now largely exceeds its first clinical apparitions in neuroimaging, whereby the method helped diagnose the early phases of cerebral ischemic stroke. The applications extend to whole-body imaging for both neoplastic and non-neoplastic diseases. This review emphasizes the integration of DWI in the genitourinary system imaging by outlining the sequence's usage in female pelvis, prostate, bladder, penis, testis and kidney MRI. In gynecologic imaging, DWI is an essential sequence for the characterization of cervix tumors and endometrial carcinomas, as well as to differentiate between leiomyosarcoma and benign leiomyoma of the uterus. In ovarian epithelial neoplasms, DWI provides key information for the characterization of solid components in heterogeneous complex ovarian masses. In prostate imaging, DWI became an essential part of multi-parametric Magnetic Resonance Imaging (mpMRI) to detect prostate cancer. The Prostate Imaging-Reporting and Data System (PI-RADS) scoring the probability of significant prostate tumors has significantly contributed to this success. Its contribution has established mpMRI as a mandatory examination for the planning of prostate biopsies and radical prostatectomy. Following a similar approach, DWI was included in multiparametric protocols for the bladder and the testis. In renal imaging, DWI is not able to robustly differentiate between malignant and benign renal tumors but may be helpful to characterize tumor subtypes, including clear-cell and non-clear-cell renal carcinomas or low-fat angiomyolipomas. One of the most promising developments of renal DWI is the estimation of renal fibrosis in chronic kidney disease (CKD) patients. In conclusion, DWI constitutes a major advancement in genitourinary imaging with a central role in decision algorithms in the female pelvis and prostate cancer, now allowing promising applications in renal imaging or in the bladder and testicular mpMRI.
Collapse
|
33
|
Multiparametric Functional MRI of the Kidney: Current State and Future Trends with Deep Learning Approaches. ROFO-FORTSCHR RONTG 2022; 194:983-992. [PMID: 35272360 DOI: 10.1055/a-1775-8633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND Until today, assessment of renal function has remained a challenge for modern medicine. In many cases, kidney diseases accompanied by a decrease in renal function remain undetected and unsolved, since neither laboratory tests nor imaging diagnostics provide adequate information on kidney status. In recent years, developments in the field of functional magnetic resonance imaging with application to abdominal organs have opened new possibilities combining anatomic imaging with multiparametric functional information. The multiparametric approach enables the measurement of perfusion, diffusion, oxygenation, and tissue characterization in one examination, thus providing more comprehensive insight into pathophysiological processes of diseases as well as effects of therapeutic interventions. However, application of multiparametric fMRI in the kidneys is still restricted mainly to research areas and transfer to the clinical routine is still outstanding. One of the major challenges is the lack of a standardized protocol for acquisition and postprocessing including efficient strategies for data analysis. This article provides an overview of the most common fMRI techniques with application to the kidney together with new approaches regarding data analysis with deep learning. METHODS This article implies a selective literature review using the literature database PubMed in May 2021 supplemented by our own experiences in this field. RESULTS AND CONCLUSION Functional multiparametric MRI is a promising technique for assessing renal function in a more comprehensive approach by combining multiple parameters such as perfusion, diffusion, and BOLD imaging. New approaches with the application of deep learning techniques could substantially contribute to overcoming the challenge of handling the quantity of data and developing more efficient data postprocessing and analysis protocols. Thus, it can be hoped that multiparametric fMRI protocols can be sufficiently optimized to be used for routine renal examination and to assist clinicians in the diagnostics, monitoring, and treatment of kidney diseases in the future. KEY POINTS · Multiparametric fMRI is a technique performed without the use of radiation, contrast media, and invasive methods.. · Multiparametric fMRI provides more comprehensive insight into pathophysiological processes of kidney diseases by combining functional and structural parameters.. · For broader acceptance of fMRI biomarkers, there is a need for standardization of acquisition, postprocessing, and analysis protocols as well as more prospective studies.. · Deep learning techniques could significantly contribute to an optimization of data acquisition and the postprocessing and interpretation of larger quantities of data.. CITATION FORMAT · Zhang C, Schwartz M, Küstner T et al. Multiparametric Functional MRI of the Kidney: Current State and Future Trends with Deep Learning Approaches. Fortschr Röntgenstr 2022; DOI: 10.1055/a-1775-8633.
Collapse
|
34
|
de Boer A, Villa G, Bane O, Bock M, Cox EF, Dekkers IA, Eckerbom P, Fernández‐Seara MA, Francis ST, Haddock B, Hall ME, Hall Barrientos P, Hermann I, Hockings PD, Lamb HJ, Laustsen C, Lim RP, Morris DM, Ringgaard S, Serai SD, Sharma K, Sourbron S, Takehara Y, Wentland AL, Wolf M, Zöllner FG, Nery F, Caroli A. Consensus-Based Technical Recommendations for Clinical Translation of Renal Phase Contrast MRI. J Magn Reson Imaging 2022; 55:323-335. [PMID: 33140551 PMCID: PMC9291014 DOI: 10.1002/jmri.27419] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 10/15/2020] [Accepted: 10/16/2020] [Indexed: 12/26/2022] Open
Abstract
BACKGROUND Phase-contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC-MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC-MRI as a clinically useful tool. PURPOSE To build technical recommendations for the acquisition, processing, and analysis of renal 2D PC-MRI data in human subjects to promote standardization of renal blood flow measurements and facilitate the comparability of results across scanners and in multicenter clinical studies. STUDY TYPE Systematic consensus process using a modified Delphi method. POPULATION Not applicable. SEQUENCE FIELD/STRENGTH Renal fast gradient echo-based 2D PC-MRI. ASSESSMENT An international panel of 27 experts from Europe, the USA, Australia, and Japan with 6 (interquartile range 4-10) years of experience in 2D PC-MRI formulated consensus statements on renal 2D PC-MRI in two rounds of surveys. Starting from a recently published systematic review article, literature-based and data-driven statements regarding patient preparation, hardware, acquisition protocol, analysis steps, and data reporting were formulated. STATISTICAL TESTS Consensus was defined as ≥75% unanimity in response, and a clear preference was defined as 60-74% agreement among the experts. RESULTS Among 60 statements, 57 (95%) achieved consensus after the second-round survey, while the remaining three showed a clear preference. Consensus statements resulted in specific recommendations for subject preparation, 2D renal PC-MRI data acquisition, processing, and reporting. DATA CONCLUSION These recommendations might promote a widespread adoption of renal PC-MRI, and may help foster the set-up of multicenter studies aimed at defining reference values and building larger and more definitive evidence, and will facilitate clinical translation of PC-MRI. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY STAGE: 1.
Collapse
Affiliation(s)
- Anneloes de Boer
- Department of RadiologyUniversity Medical Center Utrecht, Utrecht UniversityUtrechtThe Netherlands
| | - Giulia Villa
- Department of BioengineeringIstituto di Ricerche Farmacologiche Mario Negri IRCCSBergamoItaly
| | - Octavia Bane
- Biomedical Engineering and Imaging Institute/RadiologyIcahn School of Medicine at Mount SinaiNew YorkNew YorkUSA
| | - Michael Bock
- Department of Radiology ‐ Medical Physics, Medical CenterUniversity of Freiburg, Faculty of Medicine, University of FreiburgFreiburgGermany
| | - Eleanor F. Cox
- Sir Peter Mansfield Imaging Centre, School of Physics and AstronomyUniversity of NottinghamNottinghamUK
| | - Ilona A. Dekkers
- Department of RadiologyLeiden University Medical CenterLeidenThe Netherlands
| | - Per Eckerbom
- Department of Surgical SciencesUppsala UniversityUppsalaSweden
| | | | - Susan T. Francis
- Sir Peter Mansfield Imaging Centre, School of Physics and AstronomyUniversity of NottinghamNottinghamUK
| | - Bryan Haddock
- Department of Clinical Physiology, Nuclear Medicine and PET, RigshospitaletCopenhagen University HospitalCopenhagenDenmark
| | - Michael E. Hall
- Department of MedicineUniversity of Mississippi Medical CenterJacksonMississippiUSA
| | | | - Ingo Hermann
- Computer Assisted Clinical Medicine, Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty MannheimHeidelberg UniversityMannheimGermany
| | | | - Hildo J. Lamb
- Department of RadiologyLeiden University Medical CenterLeidenThe Netherlands
| | - Christoffer Laustsen
- Department of Clinical Medicine, MR Research CentreAarhus UniversityAarhusDenmark
| | - Ruth P. Lim
- Departments of Radiology, Surgery and MedicineThe University of MelbourneParkvilleVictoriaAustralia
- Department of RadiologyAustin HealthHeidelbergVictoriaAustralia
| | - David M. Morris
- Centre for Inflammation ResearchUniversity of Edinburgh, Edinburgh BioquarterEdinburghUK
| | - Steffen Ringgaard
- Department of Clinical Medicine, MR Research CentreAarhus UniversityAarhusDenmark
| | - Suraj D. Serai
- Department of RadiologyChildren's Hospital of PhiladelphiaPhiladelphiaPennsylvaniaUSA
| | - Kanishka Sharma
- Department of Imaging, Infection, Immunity and Cardiovascular DiseaseThe University of SheffieldSheffieldUK
| | - Steven Sourbron
- Department of Imaging, Infection, Immunity and Cardiovascular DiseaseThe University of SheffieldSheffieldUK
| | - Yasuo Takehara
- Department of Fundamental Development for Advanced Low Invasive Diagnostic ImagingNagoya University, Graduate School of MedicineNagoyaJapan
| | | | - Marcos Wolf
- High Field MR Center, Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
| | - Frank G. Zöllner
- Computer Assisted Clinical Medicine, Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty MannheimHeidelberg UniversityMannheimGermany
| | - Fabio Nery
- Developmental Imaging and Biophysics SectionUCL Great Ormond Street Institute of Child HealthLondonUK
| | - Anna Caroli
- Department of BioengineeringIstituto di Ricerche Farmacologiche Mario Negri IRCCSBergamoItaly
| |
Collapse
|
35
|
Zhang H, Wang P, Shi D, Yao X, Li Y, Liu X, Sun Y, Ding J, Wang S, Wang G, Ren K. Capability of intravoxel incoherent motion and diffusion tensor imaging to detect early kidney injury in type 2 diabetes. Eur Radiol 2022; 32:2988-2997. [PMID: 35031840 DOI: 10.1007/s00330-021-08415-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 10/11/2021] [Accepted: 10/13/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVES To prospectively investigate the capability of intravoxel incoherent motion (IVIM) and conventional diffusion tensor imaging (DTI) to identify early kidney function injury in type 2 diabetes. METHODS Forty-one diabetes patients (normoalbuminuria: n = 27; microalbuminuria: n = 14) and 28 volunteers were recruited. All participants were examined using DTI and IVIM with 3.0-T MRI. DTI parameters (mean diffusivity [MD], fractional anisotropy [FA]), and IVIM parameters (true diffusion coefficient [D], pseudo-diffusion coefficient [D*], and pseudo-diffusion component fraction [f]) were measured in the renal parenchyma (cortex and medulla) by two experienced radiologists independently. Image features were compared among the groups using separate one-way analyses of variance. Diagnostic performances of various diffusion parameters for predicting diabetic renal damage were compared. RESULTS The medullary D and FA values were significantly different among the microalbuminuria subgroup, normoalbuminuria subgroup, and control group (all p < 0.001). In medulla, area under the curve (AUC) values for combined FA and D were significantly higher than single FA (AUC = 0.938, 0.769, respectively; p = 0.003), and the combined AUC of FA and D was numerically higher than that of single D (0.938 vs 0.878, p > 0.05). AUC of combined FA and D was 0.985, not significantly different from individual AUC for FA and D (AUC = 0.909 and 0.952, respectively; all p > 0.05) in differentiating the microalbuminuria subgroup from the control group. CONCLUSION IVIM-derived D and DTI-derived FA values were better than other parameters for evaluating early kidney impairment of diabetes. The single indicator FA and D performed as well as the combined diagnostic indicator in the medulla for differentiating the microalbuminuria subgroup from the control group. KEY POINTS • We speculated that early renal progression in type 2 diabetes result from restricted tubular flow and kidney tubule dysregulation may precede or at least accompany abnormal glomerular changes. • In medulla, the AUC values of FA and D and the combination of FA and D obtained by comparing the microalbuminuria subgroup with the control group were 0.909, 0.952, and 0.985, respectively. • IVIM-derived D and DTI-derived FA are effective MR biomarkers to evaluate early alterations of the renal function in patients with diabetes.
Collapse
Affiliation(s)
- Haoran Zhang
- Department of Radiology, Xiang'an Hospital of Xiamen University, Xiamen, 361005, China
| | - Peng Wang
- Department of Radiology, The First Hospital of China Medical University, Shenyang, China
| | - Dafa Shi
- Department of Radiology, Xiang'an Hospital of Xiamen University, Xiamen, 361005, China
| | - Xiang Yao
- Department of Radiology, Xiang'an Hospital of Xiamen University, Xiamen, 361005, China
| | - Yanfei Li
- Department of Radiology, Xiang'an Hospital of Xiamen University, Xiamen, 361005, China
| | - Xuedan Liu
- Department of Radiology, Xiang'an Hospital of Xiamen University, Xiamen, 361005, China
| | - Yang Sun
- Department of Radiology, Xiang'an Hospital of Xiamen University, Xiamen, 361005, China
| | - Jie Ding
- Department of Radiology, Xiang'an Hospital of Xiamen University, Xiamen, 361005, China
| | - Siyuan Wang
- Department of Radiology, Xiang'an Hospital of Xiamen University, Xiamen, 361005, China
| | - Guangsong Wang
- Department of Radiology, Xiang'an Hospital of Xiamen University, Xiamen, 361005, China
| | - Ke Ren
- Department of Radiology, Xiang'an Hospital of Xiamen University, Xiamen, 361005, China. .,Xiamen Key Laboratory of Endocrine-Related Cancer Precision Medicine, Xiamen, China.
| |
Collapse
|
36
|
Weingärtner S, Desmond KL, Obuchowski NA, Baessler B, Zhang Y, Biondetti E, Ma D, Golay X, Boss MA, Gunter JL, Keenan KE, Hernando D. Development, validation, qualification, and dissemination of quantitative MR methods: Overview and recommendations by the ISMRM quantitative MR study group. Magn Reson Med 2021; 87:1184-1206. [PMID: 34825741 DOI: 10.1002/mrm.29084] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 10/20/2021] [Accepted: 10/27/2021] [Indexed: 12/26/2022]
Abstract
On behalf of the International Society for Magnetic Resonance in Medicine (ISMRM) Quantitative MR Study Group, this article provides an overview of considerations for the development, validation, qualification, and dissemination of quantitative MR (qMR) methods. This process is framed in terms of two central technical performance properties, i.e., bias and precision. Although qMR is confounded by undesired effects, methods with low bias and high precision can be iteratively developed and validated. For illustration, two distinct qMR methods are discussed throughout the manuscript: quantification of liver proton-density fat fraction, and cardiac T1 . These examples demonstrate the expansion of qMR methods from research centers toward widespread clinical dissemination. The overall goal of this article is to provide trainees, researchers, and clinicians with essential guidelines for the development and validation of qMR methods, as well as an understanding of necessary steps and potential pitfalls for the dissemination of quantitative MR in research and in the clinic.
Collapse
Affiliation(s)
- Sebastian Weingärtner
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Kimberly L Desmond
- Brain Health Imaging Centre, Centre for Addiction and Mental Health, Toronto, Ontario, Canada.,Department of Psychiatry, University of Toronto, Toronto, Ontario, Canada
| | - Nancy A Obuchowski
- Department of Quantitative Health Sciences, Cleveland Clinic, Cleveland, Ohio, USA
| | - Bettina Baessler
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland
| | - Yuxin Zhang
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Emma Biondetti
- Department of Neuroscience, Imaging and Clinical Sciences, D'Annunzio University of Chieti and Pescara, Chieti, Italy
| | - Dan Ma
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| | - Xavier Golay
- Brain Repair & Rehabilitation, Institute of Neurology, University College London, United Kingdom.,Gold Standard Phantoms Limited, Rochester, United Kingdom
| | - Michael A Boss
- Center for Research and Innovation, American College of Radiology, Philadelphia, Pennsylvania, USA
| | | | - Kathryn E Keenan
- National Institute of Standards and Technology, Boulder, Colorado, USA
| | - Diego Hernando
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | | |
Collapse
|
37
|
Rankin AJ, Mayne K, Allwood-Spiers S, Hall Barrientos P, Roditi G, Gillis KA, Mark PB. Will advances in functional renal magnetic resonance imaging translate to the nephrology clinic? Nephrology (Carlton) 2021; 27:223-230. [PMID: 34724286 DOI: 10.1111/nep.13985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 10/01/2021] [Accepted: 10/09/2021] [Indexed: 11/28/2022]
Abstract
Characterizing structural and tissue abnormalities of the kidney is fundamental to understanding kidney disease. Functional multi-parametric renal magnetic resonance imaging (MRI) is a noninvasive imaging strategy whereby several sequences are employed within a single session to quantify renal perfusion, tissue oxygenation, fibrosis, inflammation, and oedema without using ionizing radiation. In this review, we discuss evidence surrounding its use in several clinical settings including acute kidney injury, chronic kidney disease, hypertension, polycystic kidney disease and around renal transplantation. Kidney size on MRI is already a validated measure for making therapeutic decisions in the setting of polycystic kidney disease. Functional MRI sequences, T1 mapping and apparent diffusion coefficient, can non-invasively quantify interstitial fibrosis and so may have a near-future role in the nephrology clinic to stratify the risk of progressive chronic kidney disease or transplant dysfunction. Beyond this, multi-parametric MRI may be used diagnostically, for example differentiating inflammatory versus ischaemic causes of renal dysfunction, but this remains to be proven. Changes in MRI properties of kidney parenchyma may be useful surrogate markers to use as end points in clinical trials to assess if drugs prevent renal fibrosis or alter kidney perfusion. Large, multi-centre studies of functional renal MRI are ongoing which aim to provide definitive answers as to its role in the management of patients with renal dysfunction.
Collapse
Affiliation(s)
- Alastair J Rankin
- Institute of Cardiovascular & Medical Sciences, University of Glasgow, Glasgow, UK.,Glasgow Renal and Transplant Unit, Queen Elizabeth University Hospital, Glasgow, UK
| | - Kaitlin Mayne
- Institute of Cardiovascular & Medical Sciences, University of Glasgow, Glasgow, UK.,Glasgow Renal and Transplant Unit, Queen Elizabeth University Hospital, Glasgow, UK
| | - Sarah Allwood-Spiers
- Department of Clinical Physics and Bioengineering, NHS Greater Glasgow & Clyde, Glasgow, UK
| | | | - Giles Roditi
- Institute of Cardiovascular & Medical Sciences, University of Glasgow, Glasgow, UK.,Department of Radiology, NHS Greater Glasgow & Clyde, Glasgow, UK
| | - Keith A Gillis
- Institute of Cardiovascular & Medical Sciences, University of Glasgow, Glasgow, UK.,Glasgow Renal and Transplant Unit, Queen Elizabeth University Hospital, Glasgow, UK
| | - Patrick B Mark
- Institute of Cardiovascular & Medical Sciences, University of Glasgow, Glasgow, UK.,Glasgow Renal and Transplant Unit, Queen Elizabeth University Hospital, Glasgow, UK
| |
Collapse
|
38
|
Lin L, Zhou X, Dekkers IA, Lamb HJ. Cardiorenal Syndrome: Emerging Role of Medical Imaging for Clinical Diagnosis and Management. J Pers Med 2021; 11:734. [PMID: 34442378 PMCID: PMC8400880 DOI: 10.3390/jpm11080734] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Revised: 07/24/2021] [Accepted: 07/24/2021] [Indexed: 12/16/2022] Open
Abstract
Cardiorenal syndrome (CRS) concerns the interconnection between heart and kidneys in which the dysfunction of one organ leads to abnormalities of the other. The main clinical challenges associated with cardiorenal syndrome are the lack of tools for early diagnosis, prognosis, and evaluation of therapeutic effects. Ultrasound, computed tomography, nuclear medicine, and magnetic resonance imaging are increasingly used for clinical management of cardiovascular and renal diseases. In the last decade, rapid development of imaging techniques provides a number of promising biomarkers for functional evaluation and tissue characterization. This review summarizes the applicability as well as the future technological potential of each imaging modality in the assessment of CRS. Furthermore, opportunities for a comprehensive imaging approach for the evaluation of CRS are defined.
Collapse
Affiliation(s)
- Ling Lin
- Cardiovascular Imaging Group (CVIG), Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands; (L.L.); (I.A.D.); (H.J.L.)
| | - Xuhui Zhou
- Department of Radiology, The Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen 510833, China
| | - Ilona A. Dekkers
- Cardiovascular Imaging Group (CVIG), Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands; (L.L.); (I.A.D.); (H.J.L.)
| | - Hildo J. Lamb
- Cardiovascular Imaging Group (CVIG), Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands; (L.L.); (I.A.D.); (H.J.L.)
| |
Collapse
|
39
|
Lee SK, Lee J, Jang S, Lee E, Jeon CY, Lim KS, Jin YB, Choi J. Renal Diffusion-Weighted Imaging in Healthy Dogs: Reproducibility, Test-Retest Repeatability, and Selection of the Optimal b-value Combination. Front Vet Sci 2021; 8:641971. [PMID: 34277748 PMCID: PMC8282824 DOI: 10.3389/fvets.2021.641971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Accepted: 06/08/2021] [Indexed: 11/13/2022] Open
Abstract
Diffusion-weighted imaging (DWI) magnetic resonance imaging can evaluate alterations in the microstructure of the kidney. The purpose of this study was to assess the apparent diffusion coefficient (ADC) and the intravoxel incoherent motion model (IVIM) parameters of a normal kidney in healthy dogs, to evaluate the effect of b-value combinations on the ADC value, and the reproducibility and test-retest repeatability in monoexponential and IVIM analysis. In this experimental study, the ADC, pure diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f p) were measured from both kidneys in nine healthy beagles using nine b-values (b = 0, 50, 70, 100, 150, 200, 500, 800, and 1,000 s/mm2) twice with a 1-week interval between measurements. Interobserver and intraobserver reproducibility, and test-retest repeatability of the measurements were calculated. ADC values were measured using 10 different b-value combinations consisting of three b-values each, and were compared to the ADC obtained from nine b-values. All the ADC, D, D*, and f p values measured from the renal cortex, medulla, and the entire kidney had excellent interobserver and intraobserver reproducibility, and test-retest repeatability. The ADC obtained from a b-value combination of 0, 100, and 800 s/mm2 had the highest intraclass correlation coefficient with the ADC from nine b-values. The results of this study indicated that DWI MRI using multiple b-values is feasible for the measurement of ADC and IVIM parameters with high reproducibility and repeatability in the kidneys of healthy dogs. A combination of b = 0, 100, and 800 s/mm2 can be used for ADC measurements when multiple b-values are not available in dogs.
Collapse
Affiliation(s)
- Sang-Kwon Lee
- College of Veterinary Medicine and BK21 Plus Project Team, Chonnam National University, Gwangju, South Korea
| | - Juryeoung Lee
- College of Veterinary Medicine and BK21 Plus Project Team, Chonnam National University, Gwangju, South Korea
| | - Seolyn Jang
- College of Veterinary Medicine and BK21 Plus Project Team, Chonnam National University, Gwangju, South Korea
| | - Eunji Lee
- College of Veterinary Medicine and BK21 Plus Project Team, Chonnam National University, Gwangju, South Korea
| | - Chang-Yeop Jeon
- National Primate Research Center, Korea Research Institute of Bioscience and Biotechnology, Cheongju, South Korea
| | - Kyung-Seoub Lim
- Futuristic Animal Resource and Research Center, Korea Research Institute of Bioscience and Biotechnology, Cheongju, South Korea
| | - Yeung Bae Jin
- College of Veterinary Medicine, Gyeongsang National University, Jinju, South Korea
| | - Jihye Choi
- College of Veterinary Medicine and BK21 Plus Project Team, Chonnam National University, Gwangju, South Korea
| |
Collapse
|
40
|
Periquito JS, Gladytz T, Millward JM, Delgado PR, Cantow K, Grosenick D, Hummel L, Anger A, Zhao K, Seeliger E, Pohlmann A, Waiczies S, Niendorf T. Continuous diffusion spectrum computation for diffusion-weighted magnetic resonance imaging of the kidney tubule system. Quant Imaging Med Surg 2021; 11:3098-3119. [PMID: 34249638 DOI: 10.21037/qims-20-1360] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 03/08/2021] [Indexed: 12/24/2022]
Abstract
Background The use of rigid multi-exponential models (with a priori predefined numbers of components) is common practice for diffusion-weighted MRI (DWI) analysis of the kidney. This approach may not accurately reflect renal microstructure, as the data are forced to conform to the a priori assumptions of simplified models. This work examines the feasibility of less constrained, data-driven non-negative least squares (NNLS) continuum modelling for DWI of the kidney tubule system in simulations that include emulations of pathophysiological conditions. Methods Non-linear least squares (LS) fitting was used as reference for the simulations. For performance assessment, a threshold of 5% or 10% for the mean absolute percentage error (MAPE) of NNLS and LS results was used. As ground truth, a tri-exponential model using defined volume fractions and diffusion coefficients for each renal compartment (tubule system: Dtubules , ftubules ; renal tissue: Dtissue , ftissue ; renal blood: Dblood , fblood ;) was applied. The impact of: (I) signal-to-noise ratio (SNR) =40-1,000, (II) number of b-values (n=10-50), (III) diffusion weighting (b-rangesmall =0-800 up to b-rangelarge =0-2,180 s/mm2), and (IV) fixation of the diffusion coefficients Dtissue and Dblood was examined. NNLS was evaluated for baseline and pathophysiological conditions, namely increased tubular volume fraction (ITV) and renal fibrosis (10%: grade I, mild) and 30% (grade II, moderate). Results NNLS showed the same high degree of reliability as the non-linear LS. MAPE of the tubular volume fraction (ftubules ) decreased with increasing SNR. Increasing the number of b-values was beneficial for ftubules precision. Using the b-rangelarge led to a decrease in MAPE ftubules compared to b-rangesmall. The use of a medium b-value range of b=0-1,380 s/mm2 improved ftubules precision, and further bmax increases beyond this range yielded diminishing improvements. Fixing Dblood and Dtissue significantly reduced MAPE ftubules and provided near perfect distinction between baseline and ITV conditions. Without constraining the number of renal compartments in advance, NNLS was able to detect the (fourth) fibrotic compartment, to differentiate it from the other three diffusion components, and to distinguish between 10% vs. 30% fibrosis. Conclusions This work demonstrates the feasibility of NNLS modelling for DWI of the kidney tubule system and shows its potential for examining diffusion compartments associated with renal pathophysiology including ITV fraction and different degrees of fibrosis.
Collapse
Affiliation(s)
- Joāo S Periquito
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.,Institute of Physiology, Charité - Universitätsmedizin Berlin, Campus Mitte, Berlin, Germany.,Experimental and Clinical Research Center, a Joint Cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Thomas Gladytz
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Jason M Millward
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Paula Ramos Delgado
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.,Experimental and Clinical Research Center, a Joint Cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Kathleen Cantow
- Institute of Physiology, Charité - Universitätsmedizin Berlin, Campus Mitte, Berlin, Germany
| | - Dirk Grosenick
- Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany
| | - Luis Hummel
- Institute of Physiology, Charité - Universitätsmedizin Berlin, Campus Mitte, Berlin, Germany
| | - Ariane Anger
- Institute of Physiology, Charité - Universitätsmedizin Berlin, Campus Mitte, Berlin, Germany
| | - Kaixuan Zhao
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Erdmann Seeliger
- Institute of Physiology, Charité - Universitätsmedizin Berlin, Campus Mitte, Berlin, Germany
| | - Andreas Pohlmann
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Sonia Waiczies
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.,Experimental and Clinical Research Center, a Joint Cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| |
Collapse
|
41
|
Wáng YXJ. Mutual constraining of slow component and fast component measures: some observations in liver IVIM imaging. Quant Imaging Med Surg 2021; 11:2879-2887. [PMID: 34079748 DOI: 10.21037/qims-21-187] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Yì Xiáng J Wáng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
42
|
Wang YXJ, Huang H, Zheng CJ, Xiao BH, Chevallier O, Wang W. Diffusion-weighted MRI of the liver: challenges and some solutions for the quantification of apparent diffusion coefficient and intravoxel incoherent motion. AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING 2021; 11:107-142. [PMID: 34079640 PMCID: PMC8165724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Accepted: 03/09/2021] [Indexed: 06/12/2023]
Abstract
Diffusion-weighted imaging (DWI) is sensitive to the mobility of water molecule at cellular and macromolecular level, much smaller than the spatial resolution of the images. It is commonly based on single shot echo-planar imaging sequence with the addition of motion-probing gradient pulses and fat suppression. DWI is increasingly incorporated into routine body magnetic resonance imaging protocols. However, the liver is particularly affected by physiological motions such as respiration; the left liver is also affected by cardiac motion artifacts and susceptibility artefact due to contents in the stomach. Intravoxel incoherent motion (IVIM) DWI data analysis requires high-quality data acquisition using multiple b-values and confidence in the measurements at low b-values. This article reviews the technical developments of DWI and its applications in the liver. Challenges and some solutions for the quantification of apparent diffusion coefficient and intravoxel incoherent motion are discussed. Currently, acquisition protocols vary between research groups; patient preparation and data post-processing are not standardized. Increased standardization, both in data acquisition and in image analysis, is imperative so to allow generation of reliable DW-MRI biomarker measures that are broadly applicable.
Collapse
Affiliation(s)
- Yi Xiang J Wang
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong KongNew Territories, Hong Kong SAR, China
| | - Hua Huang
- Department of Radiology, The Third People’s Hospital of Shenzhen, The Second Affiliated Hospital of Southern University of Science and Technology, National Clinical Research Center for Infectious DiseasesShenzhen, Guangdong Province, China
| | - Cun-Jing Zheng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong KongNew Territories, Hong Kong SAR, China
| | - Ben-Heng Xiao
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong KongNew Territories, Hong Kong SAR, China
| | - Olivier Chevallier
- Department of Vascular and Interventional Radiology, François-Mitterrand Teaching Hospital, Université de BourgogneDijon, France
| | - Wei Wang
- Department of Radiology, The Third Xiangya Hospital, Central South UniversityChangsha, Hunan Province, China
| |
Collapse
|
43
|
Zheng SS, He YM, Lu J. Noninvasive evaluation of diabetic patients with high fasting blood glucose using DWI and BOLD MRI. Abdom Radiol (NY) 2021; 46:1659-1669. [PMID: 32997155 DOI: 10.1007/s00261-020-02780-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 09/10/2020] [Accepted: 09/21/2020] [Indexed: 12/19/2022]
Abstract
PURPOSE To investigate the renal microstructure changes and hypoxia changes in type 2 diabetic patients and the relationship between them and glucose using both diffusion-weighted imaging (DWI) and blood oxygenation level-dependent magnetic resonance imaging (BOLD MRI). METHODS After measuring morning fasting blood glucose, DWI and BOLD MRI were performed in 57 patients with type 2 diabetes mellitus (DM group) and 14 healthy volunteers (NC group). According to the fasting blood glucose levels, diabetic patients were divided into a normoglycemic diabetes group (group A), a less hyperglycemic diabetes group (group B) and a more hyperglycemic diabetes group (group C). The renal parenchymal apparent diffusion coefficient (ADC), renal cortical R2* (CR2*), and medullary R2* (MR2*) were measured, and the R2* ratio between the medulla and cortex (MCR) was calculated. To test for differences in ADC, R2*, and MCR among the four groups, the data were analyzed by separate one-way ANOVAs. The correlations between ADC, R2*, and MCR and the clinical index of renal function were analyzed. RESULTS Groups B and C had significantly lower ADC values in the renal parenchyma (P = 0.048, 0.002) and significantly higher MR2* and MCR values (P < 0.000, P = 0.001, 0.001, and 0.005, respectively) than the NC group. ADC was negatively correlated with glucose, and MR2*, MCR and glucose showed a weak positive correlation. CONCLUSION DWI and BOLD may indirectly and qualitatively reflect the kidney microstructure status and hypoxia level of diabetic patients at different blood glucose levels to a certain extent, and possibly guide the clinical treatment of diabetic patients with different blood glucose levels.
Collapse
Affiliation(s)
- Shuang-Shuang Zheng
- Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, 100053, China
- Department of Radiology, Fuxing Hospital, Capital Medical University, Beijing, 100038, China
| | - Yue-Ming He
- Department of Radiology, Fuxing Hospital, Capital Medical University, Beijing, 100038, China
| | - Jie Lu
- Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, 100053, China.
- Department of Nuclear Medicine, Xuanwu Hospital, Capital Medical University, Beijing, 100053, China.
- Beijing Key Laboratory of Magnetic Resonance Imaging and Brain Informatics, Beijing, 100053, China.
| |
Collapse
|
44
|
Lim RP, Lim JC, Teruel JR, Botterill E, Seah JM, Farquharson S, Ekinci EI, Sigmund EE. Geometric Distortion Correction of Renal Diffusion Tensor Imaging Using the Reversed Gradient Method. J Comput Assist Tomogr 2021; 45:218-223. [PMID: 33661149 PMCID: PMC8194095 DOI: 10.1097/rct.0000000000001124] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
ABSTRACT Renal echo planar diffusion tensor imaging (DTI) has clinical potential but suffers from geometric distortion. We evaluated feasibility of reversed gradient distortion correction in 10 diabetic patients and 6 volunteers. Renal area, apparent diffusion coefficient, fractional anisotropy, and tensor eigenvalues were measured on uncorrected and distortion-corrected DTI. Corrected DTI correlated better than uncorrected DTI (r = 0.904 vs 0.840, P = 0.002) with reference anatomic T2-weighted imaging, with no significant difference in DTI metrics.
Collapse
Affiliation(s)
- Ruth P. Lim
- Austin Health, Radiology and Surgery, The University of Melbourne, Melbourne, Australia
- Department of Medicine, Radiology and Surgery, The University of Melbourne, Melbourne, Australia
| | - Jeremy C. Lim
- Austin Health, Radiology and Surgery, The University of Melbourne, Melbourne, Australia
| | - Jose R. Teruel
- Department of Radiation Oncology, NYU Langone Health, New York, NY
| | - Elissa Botterill
- Austin Health, Radiology and Surgery, The University of Melbourne, Melbourne, Australia
| | - Jas-mine Seah
- Austin Health, Radiology and Surgery, The University of Melbourne, Melbourne, Australia
| | - Shawna Farquharson
- The Florey Institute of Neuroscience and Mental Health, Melbourne, Australia
| | - Elif I. Ekinci
- Austin Health, Radiology and Surgery, The University of Melbourne, Melbourne, Australia
- Department of Medicine, Radiology and Surgery, The University of Melbourne, Melbourne, Australia
| | - Eric E. Sigmund
- Department of Radiology, NYU Langone Medical Center, New York, NY
| |
Collapse
|
45
|
Abstract
Interstitial fibrosis with tubule atrophy (IF/TA) is the response to virtually any sustained kidney injury and correlates inversely with kidney function and allograft survival. IF/TA is driven by various pathways that include hypoxia, renin-angiotensin-aldosterone system, transforming growth factor (TGF)-β signaling, cellular rejection, inflammation and others. In this review we will focus on key pathways in the progress of renal fibrosis, diagnosis and therapy of allograft fibrosis. This review discusses the role and origin of myofibroblasts as matrix producing cells and therapeutic targets in renal fibrosis with a particular focus on renal allografts. We summarize current trends to use multi-omic approaches to identify new biomarkers for IF/TA detection and to predict allograft survival. Furthermore, we review current imaging strategies that might help to identify and follow-up IF/TA complementary or as alternative to invasive biopsies. We further discuss current clinical trials and therapeutic strategies to treat kidney fibrosis.Supplemental Visual Abstract; http://links.lww.com/TP/C141.
Collapse
|
46
|
Li LP, Thacker JM, Li W, Hack B, Wang C, Kohn O, Sprague SM, Prasad PV. Medullary Blood Oxygen Level-Dependent MRI Index (R2*) is Associated with Annual Loss of Kidney Function in Moderate CKD. Am J Nephrol 2021; 51:966-974. [PMID: 33508835 DOI: 10.1159/000512854] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Accepted: 11/06/2020] [Indexed: 12/16/2022]
Abstract
BACKGROUND The estimated glomerular filtration rate (eGFR) is frequently used to monitor progression of kidney disease. Multiple values have to be obtained, sometimes over years to determine the rate of decline in kidney function. Recent data suggest that functional MRI (fMRI) methods may be able to predict loss of eGFR. In a prior study, baseline data with multi-parametric MRI in individuals with diabetes and moderate CKD was reported. This report extends our prior observations in order to evaluate the temporal variability of the fMRI measurements over 36 months and their association with annual change in eGFR. METHODS Twenty-four subjects with moderate CKD completed 3 sets of MRI scans over a 36-month period. Blood oxygenation level-dependent (BOLD), arterial spin labeling perfusion, and diffusion MRI images were acquired using a 3 T scanner. Coefficients of variation was used to evaluate variability between subjects at each time point and temporal variability within each subject. We have conducted mixed effects models to examine the trajectory change in GFR over time using time and MRI variables as fixed effects and baseline intercept as random effect. Associations of MRI image markers with annual change in eGFR were evaluated. RESULTS Multi-parametric functional renal MRI techniques in individuals with moderate CKD showed higher temporal variability in R2* of medulla compared to healthy individuals. This was consistent with the significant lower R2* in medulla observed at 36 months compared to baseline values. The results of linear mixed model showing that R2*_Medulla was the only predictor associated with change in eGFR over time. Furthermore, a significant association of medullary R2* with annual loss of eGFR was observed at all the 3 time points. CONCLUSIONS The lower R2* values and the higher temporal variability in the renal medulla over time suggest the ability to monitor progressive CKD. These were confirmed by the fact that reduced medullary R2* was associated with higher annual loss in eGFR. These data collectively emphasize the need for inclusion of medulla in the analysis of renal BOLD MRI studies.
Collapse
Affiliation(s)
- Lu-Ping Li
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois, USA
- Pritzker School of Medicine, University of Chicago, Chicago, Illinois, USA
| | - Jon M Thacker
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois, USA
| | - Wei Li
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois, USA
- Pritzker School of Medicine, University of Chicago, Chicago, Illinois, USA
| | - Bradley Hack
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois, USA
| | - Chi Wang
- Biostatistics, NorthShore University HealthSystem, Evanston, Illinois, USA
| | - Orly Kohn
- Pritzker School of Medicine, University of Chicago, Chicago, Illinois, USA
| | - Stuart M Sprague
- Pritzker School of Medicine, University of Chicago, Chicago, Illinois, USA
- Department of Medicine, NorthShore University HealthSystem, Evanston, Illinois, USA
| | - Pottumarthi V Prasad
- Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois, USA,
- Pritzker School of Medicine, University of Chicago, Chicago, Illinois, USA,
| |
Collapse
|
47
|
Stabinska J, Ljimani A, Zöllner HJ, Wilken E, Benkert T, Limberg J, Esposito I, Antoch G, Wittsack HJ. Spectral diffusion analysis of kidney intravoxel incoherent motion MRI in healthy volunteers and patients with renal pathologies. Magn Reson Med 2021; 85:3085-3095. [PMID: 33462838 DOI: 10.1002/mrm.28631] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 10/22/2020] [Accepted: 11/12/2020] [Indexed: 12/12/2022]
Abstract
PURPOSE To assess the feasibility of measuring tubular and vascular signal fractions in the human kidney using nonnegative least-square (NNLS) analysis of intravoxel incoherent motion data collected in healthy volunteers and patients with renal pathologies. METHODS MR imaging was performed at 3 Tesla in 12 healthy subjects and 3 patients with various kidney pathologies (fibrotic kidney disease, failed renal graft, and renal masses). Relative signal fractions f and mean diffusivities of the diffusion components in the cortex, medulla, and renal lesions were obtained using the regularized NNLS fitting of the intravoxel incoherent motion data. Test-retest repeatability of the NNLS approach was tested in 5 volunteers scanned twice. RESULTS In the healthy kidneys, the NNLS method yielded diffusion spectra with 3 distinguishable components that may be linked to the slow tissue water diffusion, intermediate tubular and vascular flow, and fast blood flow in larger vessels with the relative signal fractions, fslow , finterm and ffast , respectively. In the pathological kidneys, the diffusion spectra varied substantially from those acquired in the healthy kidneys. Overall, the renal cyst showed substantially higher finterm and lower fslow , whereas the fibrotic kidney, failed renal graft, and renal cell carcinoma demonstrated the opposite trend. CONCLUSION NNLS-based intravoxel incoherent motion could potentially become a valuable tool in assessing changes in tubular and vascular volume fractions under pathophysiological conditions.
Collapse
Affiliation(s)
- Julia Stabinska
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Dusseldorf, Düsseldorf, Germany
| | - Alexandra Ljimani
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Dusseldorf, Düsseldorf, Germany
| | - Helge Jörn Zöllner
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Dusseldorf, Düsseldorf, Germany.,Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.,F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Enrica Wilken
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Dusseldorf, Düsseldorf, Germany
| | - Thomas Benkert
- MR Application Development, Siemens Healthcare GmbH, Erlangen, Germany
| | - Juliane Limberg
- Institute of Pathology, Medical Faculty, Heinrich Heine University Dusseldorf, Düsseldorf, Germany
| | - Irene Esposito
- Institute of Pathology, Medical Faculty, Heinrich Heine University Dusseldorf, Düsseldorf, Germany
| | - Gerald Antoch
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Dusseldorf, Düsseldorf, Germany
| | - Hans-Jörg Wittsack
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Dusseldorf, Düsseldorf, Germany
| |
Collapse
|
48
|
Abstract
PURPOSE OF REVIEW Acute kidney injury (AKI) is a common complication in critically ill patients. Understanding the pathophysiology of AKI is essential to guide patient management. Imaging techniques that inform the pathogenesis of AKI in critically ill patients are urgently needed, in both research and ultimately clinical settings. Renal contrast-enhanced ultrasonography (CEUS) and multiparametric MRI appear to be the most promising imaging techniques for exploring the pathophysiological mechanisms involved in AKI. RECENT FINDINGS CEUS and MRI can be used to noninvasively and safely evaluate renal macrocirculation and microcirculation and oxygenation in critical ill patients. These techniques show that a decrease in renal blood flow, particularly cortical blood flow, may be observed in septic AKI and may contribute to its development. MRI may be a valuable method to quantify long-term renal damage after AKI that cannot currently be detected using standard clinical approaches. SUMMARY CEUS and multiparametric renal MRI are promising imaging techniques but more evidence is needed to show how they can first be more widely used in a research setting to test key hypotheses about the pathophysiology and recovery of AKI, and then ultimately be adopted in clinical practice to guide patient management.
Collapse
Affiliation(s)
- Nicholas M Selby
- Centre for Kidney Research and Innovation, Division of Medical Sciences and Graduate Entry Medicine, University of Nottingham, UK
| | - Jacques Duranteau
- Department of Anesthesiology and Intensive Care, Paris-Saclay University, Bicêtre Hospital, Assistance Publique Hôpitaux de Paris (AP-HP), Le Kremlin-Bicêtre, France
| |
Collapse
|
49
|
Muglia VF, Salmon CEG. Editorial for "Retrospective Distortion and Motion Correction for Free-Breathing DW-MRI of the Kidneys Using Dual Echo EPI and Slice-to-Volume Registration". J Magn Reson Imaging 2021; 53:1444-1445. [PMID: 33386764 DOI: 10.1002/jmri.27468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Accepted: 10/19/2020] [Indexed: 11/06/2022] Open
Affiliation(s)
- Valdair F Muglia
- Department of Medical Imaging, Hematology and Clinical Oncology - Ribeirao Preto School of Medicine, University of Sao Paulo, Sao Paulo, Brazil
| | | |
Collapse
|
50
|
Coll-Font J, Afacan O, Hoge S, Garg H, Shashi K, Marami B, Gholipour A, Chow J, Warfield S, Kurugol S. Retrospective Distortion and Motion Correction for Free-Breathing DW-MRI of the Kidneys Using Dual-Echo EPI and Slice-to-Volume Registration. J Magn Reson Imaging 2021; 53:1432-1443. [PMID: 33382173 DOI: 10.1002/jmri.27473] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2020] [Revised: 11/27/2020] [Accepted: 11/30/2020] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Diffusion-weighted MRI (DW-MRI) of the kidneys is a technique that provides information about the microstructure of renal tissue without requiring exogenous contrasts such as gadolinium, and it can be used for diagnosis in cases of renal disease and assessing response-to-therapy. However, physiological motion and large geometric distortions due to main B0 field inhomogeneities degrade the image quality, reduce the accuracy of quantitative imaging markers, and impede their subsequent clinical applicability. PURPOSE To retrospectively correct for geometric distortion for free-breathing DW-MRI of the kidneys at 3T, in the presence of a nonstatic distortion field due to breathing and bulk motion. STUDY TYPE Prospective. SUBJECTS Ten healthy volunteers (ages 29-38, four females). FIELD STRENGTH/SEQUENCE 3T; DW-MR dual-echo echo-planar imaging (EPI) sequence (10 b-values and 17 directions) and a T2 volume. ASSESSMENT The distortion correction was evaluated subjectively (Likert scale 0-5) and numerically with cross-correlation between the DW images at b = 0 s/mm2 and a T2 volume. The intravoxel incoherent motion (IVIM) and diffusion tensor (DTI) model-fitting performance was evaluated using the root-mean-squared error (nRMSE) and the coefficient of variation (CV%) of their parameters. STATISTICAL TESTS Statistical comparisons were done using Wilcoxon tests. RESULTS The proposed method improved the Likert scores by 1.1 ± 0.8 (P < 0.05), the cross-correlation with the T2 reference image by 0.13 ± 0.05 (P < 0.05), and reduced the nRMSE by 0.13 ± 0.03 (P < 0.05) and 0.23 ± 0.06 (P < 0.05) for IVIM and DTI, respectively. The CV% of the IVIM parameters (slow and fast diffusion, and diffusion fraction for IVIM and mean diffusivity, and fractional anisotropy for DTI) was reduced by 2.26 ± 3.98% (P = 6.971 × 10-2 ), 11.24 ± 26.26% (P = 6.971 × 10-2 ), 4.12 ± 12.91% (P = 0.101), 3.22 ± 0.55% (P < 0.05), and 2.42 ± 1.15% (P < 0.05). DATA CONCLUSION The results indicate that the proposed Di + MoCo method can effectively correct for time-varying geometric distortions and for misalignments due to breathing motion. Consequently, the image quality and precision of the DW-MRI model parameters improved. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY STAGE: 1.
Collapse
Affiliation(s)
- Jaume Coll-Font
- Cardiovascular Research Center, Cardiology, Massachusetts General Hospital, 149 13th St, Charlestown, United States, 02129, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Onur Afacan
- Harvard Medical School, Boston, Massachusetts, USA
- Radiology, Boston Children's Hospital, Boston, Massachusetts, USA
| | - Scott Hoge
- Harvard Medical School, Boston, Massachusetts, USA
- Radiology, Brigham and Women's Hospital, Boston, Massachusetts, USA
| | - Harsha Garg
- Radiology, Boston Children's Hospital, Boston, Massachusetts, USA
| | - Kumar Shashi
- Radiology, Boston Children's Hospital, Boston, Massachusetts, USA
| | - Bahram Marami
- Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Ali Gholipour
- Harvard Medical School, Boston, Massachusetts, USA
- Radiology, Boston Children's Hospital, Boston, Massachusetts, USA
| | - Jeanne Chow
- Harvard Medical School, Boston, Massachusetts, USA
- Radiology, Boston Children's Hospital, Boston, Massachusetts, USA
| | - Simon Warfield
- Harvard Medical School, Boston, Massachusetts, USA
- Radiology, Boston Children's Hospital, Boston, Massachusetts, USA
| | - Sila Kurugol
- Harvard Medical School, Boston, Massachusetts, USA
- Radiology, Boston Children's Hospital, Boston, Massachusetts, USA
| |
Collapse
|