1
|
Zhang J, Luan Y, Ma Q, Hu Y, Ou R, Szydzik C, Yang Y, Trinh V, Ha N, Zhang Z, Ren G, Jia HJ, Zhang BY, Ou JZ. Large-area grown ultrathin molybdenum oxides for label-free sensitive biomarker detection. NANOSCALE 2024; 16:13061-13070. [PMID: 38887082 DOI: 10.1039/d4nr01275e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/20/2024]
Abstract
The rise of two-dimensional (2D) materials has provided a confined geometry and yielded methods for guiding electrons at the nanoscale level. 2D material-enabled electronic devices can interact and transduce the subtle charge perturbation and permit significant advancement in molecule discrimination technology with high accuracy, sensitivity, and specificity, leaving a significant impact on disease diagnosis and health monitoring. However, high-performance biosensors with scalable fabrication ability and simple protocols have yet to be fully realized due to the challenges in wafer-scale 2D film synthesis and integration with electronics. Here, we propose a molybdenum oxide (MoOx)-interdigitated electrode (IDE)-based label-free biosensing chip, which stands out for its wafer-scale dimension, tunability, ease of integration and compatibility with the complementary metal-oxide-semiconductor (CMOS) fabrication. The device surface is biofunctionalized with monoclonal anti-carcinoembryonic antigen antibodies (anti-CEA) via the linkage agent (3-aminopropyl)triethoxysilane (APTES) for carcinoembryonic antigen (CEA) detection and is characterized step-by-step to reveal the working mechanism. A wide range and real-time response of the CEA concentration from 0.1 to 100 ng mL-1 and a low limit of detection (LOD) of 0.015 ng mL-1 were achieved, meeting the clinical requirements for cancer diagnosis and prognosis in serum. The MoOx-IDE biosensor also demonstrates strong surface affinity towards molecules and high selectivity using L-cysteine (L-Cys), glycine (Gly), glucose (Glu), bovine serum albumin (BSA), and immunoglobulin G (IgG). This study showcases a simple, scalable, and low-cost strategy to create a nanoelectronic biosensing platform to achieve high-performance cancer biomarker discrimination capabilities.
Collapse
Affiliation(s)
- Jiaru Zhang
- School of Engineering, RMIT University, Melbourne 3000, Australia.
| | - Yange Luan
- School of Engineering, RMIT University, Melbourne 3000, Australia.
| | - Qijie Ma
- School of Engineering, RMIT University, Melbourne 3000, Australia.
| | - Yihong Hu
- School of Engineering, RMIT University, Melbourne 3000, Australia.
| | - Rui Ou
- School of Engineering, RMIT University, Melbourne 3000, Australia.
| | - Crispin Szydzik
- School of Engineering, RMIT University, Melbourne 3000, Australia.
| | - Yunyi Yang
- School of Science, Computing and Engineering Technologies, Swinburne University of Technology, Hawthorn, Victoria 3122, Australia
| | - Vien Trinh
- School of Engineering, RMIT University, Melbourne 3000, Australia.
| | - Nam Ha
- School of Engineering, RMIT University, Melbourne 3000, Australia.
| | - Zhenyue Zhang
- School of Engineering, RMIT University, Melbourne 3000, Australia.
| | - Guanghui Ren
- School of Engineering, RMIT University, Melbourne 3000, Australia.
| | - Hu Jun Jia
- College of Microelectronics, Xidian University, Xi'an, Shaanxi, 710000, China
| | - Bao Yue Zhang
- School of Engineering, RMIT University, Melbourne 3000, Australia.
- School of Physics and Astronomy, Monash University, Clayton, Victoria, 3800 Australia
| | - Jian Zhen Ou
- School of Engineering, RMIT University, Melbourne 3000, Australia.
| |
Collapse
|
2
|
Robinson C, Juska VB, O'Riordan A. Surface chemistry applications and development of immunosensors using electrochemical impedance spectroscopy: A comprehensive review. ENVIRONMENTAL RESEARCH 2023; 237:116877. [PMID: 37579966 DOI: 10.1016/j.envres.2023.116877] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 08/04/2023] [Accepted: 08/10/2023] [Indexed: 08/16/2023]
Abstract
Immunosensors are promising alternatives as detection platforms for the current gold standards methods. Electrochemical immunosensors have already proven their capability for the sensitive, selective, detection of target biomarkers specific to COVID-19, varying cancers or Alzheimer's disease, etc. Among the electrochemical techniques, electrochemical impedance spectroscopy (EIS) is a highly sensitive technique which examines the impedance of an electrochemical cell over a range of frequencies. There are several important critical requirements for the construction of successful impedimetric immunosensor. The applied surface chemistry and immobilisation protocol have impact on the electroanalytical performance of the developed immunosensors. In this Review, we summarise the building blocks of immunosensors based on EIS, including self-assembly monolayers, nanomaterials, polymers, immobilisation protocols and antibody orientation.
Collapse
Affiliation(s)
- Caoimhe Robinson
- Tyndall National Institute, University College Cork, T12 R5CP, Cork, Ireland
| | - Vuslat B Juska
- Tyndall National Institute, University College Cork, T12 R5CP, Cork, Ireland.
| | - Alan O'Riordan
- Tyndall National Institute, University College Cork, T12 R5CP, Cork, Ireland.
| |
Collapse
|
3
|
Fadhilah GN, Yusuf M, Sari AK, Tohari TR, Wiraswati HL, Ekawardhani S, Faridah L, Fauziah N, Anshori I, Wahyuni Hartati Y. An scFv‐Based Impedimetric Immunosensor Using SPCE/AuNP for RBD of SARS‐CoV‐2 Detection. ChemistrySelect 2023. [DOI: 10.1002/slct.202203928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
- Ghina Nur Fadhilah
- Department of Chemistry Faculty of Mathematics and Natural Sciences Universitas Padjadjaran Indonesia
| | - Muhammad Yusuf
- Department of Chemistry Faculty of Mathematics and Natural Sciences Universitas Padjadjaran Indonesia
- Molecular Biotechnology and Bioinformatics Research Center Universitas Padjadjaran Indonesia
| | - Arum Kurnia Sari
- Department of Chemistry Faculty of Mathematics and Natural Sciences Universitas Padjadjaran Indonesia
| | - Taufik Ramdani Tohari
- Molecular Biotechnology and Bioinformatics Research Center Universitas Padjadjaran Indonesia
| | - Hesti Lina Wiraswati
- Department of Parasitology Faculty of Medicine Universitas Padjadjaran Indonesia
| | - Savira Ekawardhani
- Department of Parasitology Faculty of Medicine Universitas Padjadjaran Indonesia
| | - Lia Faridah
- Department of Parasitology Faculty of Medicine Universitas Padjadjaran Indonesia
| | - Nisa Fauziah
- Department of Parasitology Faculty of Medicine Universitas Padjadjaran Indonesia
| | - Isa Anshori
- Lab-on-Chip Group Bandung Institute of Technology Indonesia
| | - Yeni Wahyuni Hartati
- Department of Chemistry Faculty of Mathematics and Natural Sciences Universitas Padjadjaran Indonesia
- Molecular Biotechnology and Bioinformatics Research Center Universitas Padjadjaran Indonesia
| |
Collapse
|
4
|
Piedimonte P, Sola L, Chiari M, Ferrari G, Sampietro M. Peptide-Based Sensor and Microfluidic Platform for IgG Antibody Detection by Differential Impedance Sensing. Methods Mol Biol 2023; 2578:191-198. [PMID: 36152288 DOI: 10.1007/978-1-0716-2732-7_13] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Serological assays enable infection screening as relatively easy-to-operate approaches compared with standard methods. In addition, to be relevant for early diagnosis, specific antibody detection is important for epidemiological surveillance and quantitative detection has potential significance for evaluating the severity and prognosis of different diseases.Here, we describe the detection process based on differential impedance sensing of IgG antibodies labeled with polystyrene nanoparticles. The electrode differential configuration, the amplification with nanoparticle functionalization, the electronic reading, and the microfluidic protocol allow to reach a limit of detection below 100 pg/mL for commercial IgG antibody spiked in buffer.
Collapse
Affiliation(s)
- Paola Piedimonte
- Department of Electronics Information and Bioengineering, Politecnico di Milano, Milan, Italy.
| | - Laura Sola
- National Research Council of Italy, Istituto di Scienze e Tecnologie Chimiche (SCITEC-CNR), Milan, Italy
| | - Marcella Chiari
- National Research Council of Italy, Istituto di Scienze e Tecnologie Chimiche (SCITEC-CNR), Milan, Italy
| | - Giorgio Ferrari
- Department of Electronics Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Marco Sampietro
- Department of Electronics Information and Bioengineering, Politecnico di Milano, Milan, Italy
| |
Collapse
|
5
|
Kosri E, Ibrahim F, Thiha A, Madou M. Micro and Nano Interdigitated Electrode Array (IDEA)-Based MEMS/NEMS as Electrochemical Transducers: A Review. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:nano12234171. [PMID: 36500794 PMCID: PMC9741053 DOI: 10.3390/nano12234171] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Accepted: 11/15/2022] [Indexed: 05/28/2023]
Abstract
Micro and nano interdigitated electrode array (µ/n-IDEA) configurations are prominent working electrodes in the fabrication of electrochemical sensors/biosensors, as their design benefits sensor achievement. This paper reviews µ/n-IDEA as working electrodes in four-electrode electrochemical sensors in terms of two-dimensional (2D) planar IDEA and three-dimensional (3D) IDEA configurations using carbon or metal as the starting materials. In this regard, the enhancement of IDEAs-based biosensors focuses on controlling the width and gap measurements between the adjacent fingers and increases the IDEA's height. Several distinctive methods used to expand the surface area of 3D IDEAs, such as a unique 3D IDEA design, integration of mesh, microchannel, vertically aligned carbon nanotubes (VACNT), and nanoparticles, are demonstrated and discussed. More notably, the conventional four-electrode system, consisting of reference and counter electrodes will be compared to the highly novel two-electrode system that adopts IDEA's shape. Compared to the 2D planar IDEA, the expansion of the surface area in 3D IDEAs demonstrated significant changes in the performance of electrochemical sensors. Furthermore, the challenges faced by current IDEAs-based electrochemical biosensors and their potential solutions for future directions are presented herein.
Collapse
Affiliation(s)
- Elyana Kosri
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Malaysia
- Centre for Innovation in Medical Engineering (CIME), Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Malaysia
| | - Fatimah Ibrahim
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Malaysia
- Centre for Innovation in Medical Engineering (CIME), Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Malaysia
- Centre of Printable Electronics, Universiti Malaya, Kuala Lumpur 50603, Malaysia
| | - Aung Thiha
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Malaysia
- Centre for Innovation in Medical Engineering (CIME), Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Malaysia
| | - Marc Madou
- Centre for Innovation in Medical Engineering (CIME), Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Malaysia
- Department of Mechanical and Aerospace Engineering, University of California Irvine, Irvine, CA 92697, USA
- School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey 64849, NL, Mexico
- Academia Mexicana de Ciencias, Ciudad de México 14400, CDMX, Mexico
| |
Collapse
|
6
|
Aydın EB, Aydın M, Sezgintürk MK. Impedimetric Detection of Calreticulin by a Disposable Immunosensor Modified with a Single-Walled Carbon Nanotube-Conducting Polymer Nanocomposite. ACS Biomater Sci Eng 2022; 8:3773-3784. [PMID: 35920068 DOI: 10.1021/acsbiomaterials.2c00499] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A label-free impedimetric immunosensing system was constructed for ultrasensitive determination of the calreticulin (CALR) biological marker in human serum samples utilizing an electrochemical impedance spectroscopy analysis technique for the first time. The new biosensor fabrication procedure consisted of electrodeposition of single-walled carbon nanotubes (SWCNTs) incorporating polymerization of an oxiran-2-yl methyl 3-(1H-pyrrol-1-yl) propanoate monomer (Pepx) onto a low-cost and disposable indium tin oxide (ITO) electrode. The SWCNTs-PPepx nanocomposite layer was prepared onto the ITO after the one-step fabrication procedure. The fabrication procedure of the immunosensor and the characteristic biomolecular interactions between the anti-CALR and CALR were characterized by electrochemical analysis and morphological monitoring techniques. Under optimum conditions, the proposed biosensor was responsive to CALR concentrations over the detection ranges of 0.015-60 pg/mL linearly, and it had a very low detection limit (4.6 fg/mL) and a favorable sensitivity (0.43 kΩ pg-1 mL cm-2). The reliability of the biosensor system in clinical analysis was investigated by successful quantification of CALR levels in human serum. Moreover, the repeatability and reproducibility results of the biosensor were evaluated by using Dixon, Grubbs, T-test, and F-tests. Consequently, the proposed biosensor was a promising method for scientific, rapid, and successful analysis of CALR in human serum samples.
Collapse
Affiliation(s)
- Elif Burcu Aydın
- Scientific and Technological Research Center, Tekirdağ Namık Kemal University, Campus Street, Tekirdağ 59030, Turkey
| | - Muhammet Aydın
- Scientific and Technological Research Center, Tekirdağ Namık Kemal University, Campus Street, Tekirdağ 59030, Turkey
| | - Mustafa Kemal Sezgintürk
- Faculty of Engineering, Bioengineering Department, Çanakkale Onsekiz Mart University, Çanakkale 17100, Turkey
| |
Collapse
|
7
|
Cho H, Shim S, Cho WW, Cho S, Baek H, Lee SM, Shin DS. Electrochemical Impedance-Based Biosensors for the Label-Free Detection of the Nucleocapsid Protein from SARS-CoV-2. ACS Sens 2022; 7:1676-1684. [PMID: 35653260 PMCID: PMC9211059 DOI: 10.1021/acssensors.2c00317] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Accepted: 05/19/2022] [Indexed: 02/06/2023]
Abstract
Diagnosis of coronavirus disease (COVID-19) is important because of the emergence and global spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Real-time polymerase chain reaction (PCR) is widely used to diagnose COVID-19, but it is time-consuming and requires sending samples to test centers. Thus, the need to detect antigens for rapid on-site diagnosis rather than PCR is increasing. We quantified the nucleocapsid (N) protein in SARS-CoV-2 using an electro-immunosorbent assay (El-ISA) and a multichannel impedance analyzer with a 96-interdigitated microelectrode sensor (ToAD). The El-ISA measures impedance signals from residual detection antibodies after sandwich assays and thus offers highly specific, label-free detection of the N protein with low cross-reactivity. The ToAD sensor enables the real-time electrochemical detection of multiple samples in conventional 96-well plates. The limit of detection for the N protein was 0.1 ng/mL with a detection range up to 10 ng/mL. This system did not detect signals for the S protein. While this study focused on detecting the N protein in SARS-CoV-2, our system can also be widely applicable to detecting various biomolecules involved in antigen-antibody interactions.
Collapse
Affiliation(s)
- Hana Cho
- Department
of Chemical and Biological Engineering, Sookmyung Women’s University, Yongsan-gu, Seoul 04310, Republic of Korea
- Industry
Collaboration Center, Sookmyung Women’s
University, Yongsan-gu, Seoul 04310, Republic
of Korea
| | - Suhyun Shim
- Department
of Chemical and Biological Engineering, Sookmyung Women’s University, Yongsan-gu, Seoul 04310, Republic of Korea
| | - Won Woo Cho
- Cantis
Inc., Ansan-si, Gyeonggi-do 15588, Republic of Korea
| | - Sungbo Cho
- Department
of Electronics Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13120, Republic of Korea
| | - Hanseung Baek
- Comprehensive
Dental Care Center, Purme Nexon Children
Rehabilitation Hospital, Mapo-gu, Seoul 03918, Republic
of Korea
| | - Sang-Myung Lee
- Cantis
Inc., Ansan-si, Gyeonggi-do 15588, Republic of Korea
| | - Dong-Sik Shin
- Department
of Chemical and Biological Engineering, Sookmyung Women’s University, Yongsan-gu, Seoul 04310, Republic of Korea
- Industry
Collaboration Center, Sookmyung Women’s
University, Yongsan-gu, Seoul 04310, Republic
of Korea
| |
Collapse
|
8
|
Honda H, Kusaka Y, Wu H, Endo H, Tsuya D, Ohnuki H. Toward a Practical Impedimetric Biosensor: A Micro-Gap Parallel Plate Electrode Structure That Suppresses Unexpected Device-to-Device Variations. ACS OMEGA 2022; 7:11017-11022. [PMID: 35415349 PMCID: PMC8991901 DOI: 10.1021/acsomega.1c06942] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Accepted: 03/08/2022] [Indexed: 05/03/2023]
Abstract
We propose a rational electrode design concept for affinity biosensors based on electrochemical impedance spectroscopy to substantially suppress unexpected device-to-device variations. On the basis that the uniformity of the current distribution affects the variation, a novel micro-gap parallel plate electrode (PPE) was developed, where two planar electrodes with edges covered with a SiO2 layer were placed face to face. The structure provides a uniform current distribution over the planar electrode surface and maximizes the contribution of the planar electrode surface to sensing. For a comparative study, we also fabricated a micro-structured interdigitated electrode (IDE) that has been widely adopted for high-sensitivity measurement, although its current is highly concentrated on the electrode edge corner. Protein G (PrG) molecules were immobilized on both electrodes to prepare an immunoglobulin G (IgG) biosensor on which the specific binding of PrG-IgG can occur. We demonstrated that the IgG sensor with the PPE has small device-to-device variations, in strong contrast to the sensor with the IDE having large device-to-device variations. The results indicate that the current distribution on the electrode surface is important to fabricating electrochemical impedance spectroscopy biosensors with small device-to-device variations. Furthermore, it was found that the PPE allows ultrasensitive detection, that is, the sensor exhibited a linear range from 1 × 10-13 to 1 × 10-7 mol/L with a detection limit of 1 × 10-14 mol/L, which is a record sensitivity at low concentrations for EIS-based IgG sensors.
Collapse
Affiliation(s)
- Haruka Honda
- Department
of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, 2-1-6 Etchujima, Koto, Tokyo 135-8533, Japan
| | - Yusuke Kusaka
- Department
of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, 2-1-6 Etchujima, Koto, Tokyo 135-8533, Japan
| | - Haiyun Wu
- Department
of Ocean Sciences, Tokyo University of Marine
Science and Technology, 4-5-7 Konan, Minato, Tokyo 108-8477, Japan
| | - Hideaki Endo
- Department
of Ocean Sciences, Tokyo University of Marine
Science and Technology, 4-5-7 Konan, Minato, Tokyo 108-8477, Japan
| | - Daiju Tsuya
- National
Institute for Material Science, 1-21 Sengen, Tsukuba, Ibaraki 305-0047, Japan
| | - Hitoshi Ohnuki
- Department
of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, 2-1-6 Etchujima, Koto, Tokyo 135-8533, Japan
| |
Collapse
|
9
|
Piedimonte P, Sola L, Cretich M, Gori A, Chiari M, Marchisio E, Borga P, Bertacco R, Melloni A, Ferrari G, Sampietro M. Differential Impedance Sensing platform for high selectivity antibody detection down to few counts: A case study on Dengue Virus. Biosens Bioelectron 2022; 202:113996. [DOI: 10.1016/j.bios.2022.113996] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 01/03/2022] [Accepted: 01/10/2022] [Indexed: 11/02/2022]
|
10
|
Pasternak G, Pentoś K, Łuczycka D, Kaźmierowska-Niemczuk M, Lewandowicz-Uszyńska A. Serum Impedance in Children with Recurrent Respiratory Infections. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1375:47-54. [DOI: 10.1007/5584_2021_689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
11
|
D’Aurelio R, Tothill IE, Salbini M, Calò F, Mazzotta E, Malitesta C, Chianella I. A Comparison of EIS and QCM NanoMIP-Based Sensors for Morphine. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:3360. [PMID: 34947709 PMCID: PMC8707575 DOI: 10.3390/nano11123360] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 12/03/2021] [Accepted: 12/06/2021] [Indexed: 12/18/2022]
Abstract
In this work we have compared two different sensing platforms for the detection of morphine as an example of a low molecular weight target analyte. For this, molecularly imprinted polymer nanoparticles (NanoMIP), synthesized with an affinity towards morphine, were attached to an electrochemical impedance spectroscopy (EIS) and a quartz crystal microbalance (QCM) sensor. Assay design, sensors fabrication, analyte sensitivity and specificity were performed using similar methods. The results showed that the EIS sensor achieved a limit of detection (LOD) of 0.11 ng·mL-1, which is three orders of magnitude lower than the 0.19 µg·mL-1 achieved using the QCM sensor. Both the EIS and the QCM sensors were found to be able to specifically detect morphine in a direct assay format. However, the QCM method required conjugation of gold nanoparticles (AuNPs) to the small analyte (morphine) to amplify the signal and achieve a LOD in the µg·mL-1 range. Conversely, the EIS sensor method was labor-intensive and required extensive data handling and processing, resulting in longer analysis times (~30-40 min). In addition, whereas the QCM enables visualization of the binding events between the target molecule and the sensor in real-time, the EIS method does not allow such a feature and measurements are taken post-binding. The work also highlighted the advantages of using QCM as an automated, rapid and multiplex sensor compared to the much simpler EIS platform used in this work, though, the QCM method will require sample preparation, especially when a sensitive (ng·mL-1) detection of a small analyte is needed.
Collapse
Affiliation(s)
- Roberta D’Aurelio
- Surface Engineering and Precision Centre, School of Aerospace, Transport and Manufacturing, Cranfield University, Cranfield, Bedford MK43 0AL, UK; (I.E.T.); (M.S.); (F.C.)
| | - Ibtisam E. Tothill
- Surface Engineering and Precision Centre, School of Aerospace, Transport and Manufacturing, Cranfield University, Cranfield, Bedford MK43 0AL, UK; (I.E.T.); (M.S.); (F.C.)
| | - Maria Salbini
- Surface Engineering and Precision Centre, School of Aerospace, Transport and Manufacturing, Cranfield University, Cranfield, Bedford MK43 0AL, UK; (I.E.T.); (M.S.); (F.C.)
- Laboratorio di Chimica Analitica, Edificio Multipiano CSEEM A6., Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali, Università del Salento, I-73100 Lecce, Italy; (E.M.); (C.M.)
| | - Francesca Calò
- Surface Engineering and Precision Centre, School of Aerospace, Transport and Manufacturing, Cranfield University, Cranfield, Bedford MK43 0AL, UK; (I.E.T.); (M.S.); (F.C.)
- Laboratorio di Chimica Analitica, Edificio Multipiano CSEEM A6., Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali, Università del Salento, I-73100 Lecce, Italy; (E.M.); (C.M.)
| | - Elisabetta Mazzotta
- Laboratorio di Chimica Analitica, Edificio Multipiano CSEEM A6., Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali, Università del Salento, I-73100 Lecce, Italy; (E.M.); (C.M.)
| | - Cosimino Malitesta
- Laboratorio di Chimica Analitica, Edificio Multipiano CSEEM A6., Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali, Università del Salento, I-73100 Lecce, Italy; (E.M.); (C.M.)
| | - Iva Chianella
- Surface Engineering and Precision Centre, School of Aerospace, Transport and Manufacturing, Cranfield University, Cranfield, Bedford MK43 0AL, UK; (I.E.T.); (M.S.); (F.C.)
| |
Collapse
|
12
|
Lee M, Park SJ, Kim G, Park C, Lee MH, Ahn JH, Lee T. A pretreatment-free electrical capacitance biosensor for exosome detection in undiluted serum. Biosens Bioelectron 2021; 199:113872. [PMID: 34902643 DOI: 10.1016/j.bios.2021.113872] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Revised: 11/16/2021] [Accepted: 12/06/2021] [Indexed: 12/18/2022]
Abstract
The exosome is considered a useful biomarker for the early diagnosis of cancer. However, pretreatment of samples used in diagnosis is time-consuming. Herein, we fabricated a capacitance-based electrical biosensor that requires no pretreatment of the sample; it is composed of a DNA aptamer/molybdenum disulfide (MoS2) heterolayer on an interdigitated micro-gap electrode (IDMGE)/printed circuit board (PCB) system for detecting exosomes in an undiluted serum sample. The DNA aptamer detects the CD63 protein on the exosome as the biomarker, while the MoS2 nanoparticle enhances electrical sensitivity. In this study, for the first time, the IDMGE system was used to amplify the electrical signal efficiently for exosome detection. The IDMGE amplifies the capacitance signal as the gap between electrodes decreases, making it easy to detect the target by utilizing the heightened sensitivity. Moreover, it is possible to immobilize a bio-probe more efficiently than with an electrical sensitivity-enhancing electrode with the same area. The thiol-modified (SH-) CD63 DNA aptamer was introduced as the bio-probe that selectively binds to the CD63 protein on the exosome surface. The capacitance signal from the IDMGE electrical sensor increased linearly with the increase in the concentration of exosomes in human serum expressed on a logarithmic scale, the detection limit being 2192.6 exosomes/mL. The proposed biosensor can detect exosomes in undiluted human serum with high selectivity and sensitivity. A blind test was also carried out to test the reliability of the biosensor. The capacitance-based electrical biosensor thus offers a new platform for cancer diagnosis in the future.
Collapse
Affiliation(s)
- Myoungro Lee
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Republic of Korea
| | - Seong Jun Park
- Department of Electrical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul, 01897, Republic of Korea
| | - Gahyeon Kim
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Republic of Korea
| | - Chulhwan Park
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Republic of Korea
| | - Min-Ho Lee
- School of Integrative Engineering, Chung-Ang University, Seoul, 06974, Republic of Korea.
| | - Jae-Hyuk Ahn
- Department of Electronics Engineering, Chungnam National University, Yuseong-gu, Daejeon 99, Republic of Korea.
| | - Taek Lee
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Republic of Korea.
| |
Collapse
|
13
|
Anthi J, Kolivoška V, Holubová B, Vaisocherová-Lísalová H. Probing polymer brushes with electrochemical impedance spectroscopy: a mini review. Biomater Sci 2021; 9:7379-7391. [PMID: 34693954 DOI: 10.1039/d1bm01330k] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Polymer brushes are frequently used as surface-tethered antifouling layers in biosensors to improve sensor surface-analyte recognition in the presence of abundant non-target molecules in complex biological samples by suppressing nonspecific interactions. However, because brushes are complex systems highly responsive to changes in their surrounding environment, studying their properties remains a challenge. Electrochemical impedance spectroscopy (EIS) is an emerging method in this context. In this mini review, we aim to elucidate the potential of EIS for investigating the physicochemical properties and structural aspects of polymer brushes. The application of EIS in brush-based biosensors is also discussed. Most common principles employed in these biosensors are presented, as well as interpretation of EIS data obtained in such setups. Overall, we demonstrate that the EIS-polymer brush pairing has a considerable potential for providing new insights into brush functionalities and designing highly sensitive and specific biosensors.
Collapse
Affiliation(s)
- Judita Anthi
- Institute of Physics of the CAS, Na Slovance 2, 182 21 Prague, Czech Republic. .,Department of Biochemistry and Microbiology, University of Chemistry and Technology Prague, Technická 3, 16628 Prague, Czech Republic
| | - Viliam Kolivoška
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Dolejškova 3, 182 23 Prague, Czech Republic.
| | - Barbora Holubová
- Department of Biochemistry and Microbiology, University of Chemistry and Technology Prague, Technická 3, 16628 Prague, Czech Republic
| | | |
Collapse
|
14
|
Aydın EB, Aydın M, Sezgintürk MK. Ultrasensitive and Selective Impedimetric Determination of Prostate Specific Membrane Antigen Based on Di-Succinimide Functionalized Polythiophene Covered Cost-Effective Indium Tin Oxide. Macromol Biosci 2021; 21:e2100173. [PMID: 34263542 DOI: 10.1002/mabi.202100173] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Revised: 06/26/2021] [Indexed: 11/09/2022]
Abstract
A new and ultrasensitive impedimetric biosensor fabricated by using conjugated di-succinimide substituted polythiophene (P(ThidiSuc)) polymer modified indium tin oxide electrode is developed for the first time to detect the prostate specific membrane antigen (PSMA). The polymer P(Thi-diSuc) is synthesized by using a simple way and used in the fabrication of the proposed biosensor. The synthesized polymer contains di-succinimide groups, which offers covalent immobilization of PSMA specific antibodies. The developed strategy shortens the biosensor fabrication steps, because these active groups bind covalently to the amino ends of PSMA specific antibodies and this reaction does not require any crosslinking agent. Various characterization studies like impedimetric and voltammetric measurements, and morphological analyses are utilized to confirm the successful development of the biosensor. Under optimum conditions, the biosensing ability of the PSMA determination has a wide linear determination range from 0.015 to 14.4 pg mL-1 , as well as a low limit of detection of 6.4 fg mL-1 and a high sensitivity of 1.36 kohm pg-1 mL cm-2 . Furthermore, the proposed biosensor is able to measure the PSMA antigen in real human serums, which offers that it is a simple, low-cost, and sensitive tool with excellent potential for application in the quantification of PSMA.
Collapse
Affiliation(s)
- Elif Burcu Aydın
- Scientific and Technological Research Center, Tekirdağ Namık Kemal University, Tekirdağ, 59100, Turkey
| | - Muhammet Aydın
- Scientific and Technological Research Center, Tekirdağ Namık Kemal University, Tekirdağ, 59100, Turkey
| | - Mustafa Kemal Sezgintürk
- Faculty of Engineering, Bioengineering Department, Çanakkale Onsekiz Mart University, Çanakkale, 17020, Turkey
| |
Collapse
|
15
|
Development of an Interdigitated Electrode-Based Disposable Enzyme Sensor Strip for Glycated Albumin Measurement. Molecules 2021; 26:molecules26030734. [PMID: 33572552 PMCID: PMC7866809 DOI: 10.3390/molecules26030734] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2020] [Revised: 01/25/2021] [Accepted: 01/25/2021] [Indexed: 11/18/2022] Open
Abstract
Glycated albumin (GA) is an important glycemic control marker for diabetes mellitus. This study aimed to develop a highly sensitive disposable enzyme sensor strip for GA measurement by using an interdigitated electrode (IDE) as an electrode platform. The superior characteristics of IDE were demonstrated using one microelectrode of the IDE pair as the working electrode (WE) and the other as the counter electrode, and by measuring ferrocyanide/ferricyanide redox couple. The oxidation current was immediately reached at the steady state when the oxidation potential was applied to the WE. Then, an IDE enzyme sensor strip for GA measurement was prepared. The measurement of fructosyl lysine, the protease digestion product of GA, exhibited a high, steady current immediately after potential application, revealing the highly reproducible measurement. The sensitivity (2.8 nA µM−1) and the limit of detection (1.2 µM) obtained with IDE enzyme sensor strip were superior compared with our previously reported sensor using screen printed electrode. Two GA samples, 15 or 30% GA, corresponding to healthy and diabetic levels, respectively, were measured after protease digestion with high resolution. This study demonstrated that the application of an IDE will realize the development of highly sensitive disposable-type amperometric enzyme sensors with high reproducibility.
Collapse
|
16
|
Wei Y, Chin K, Barge LM, Perl S, Hermis N, Wei T. Machine Learning Analysis of the Thermodynamic Responses of In Situ Dielectric Spectroscopy Data in Amino Acids and Inorganic Electrolytes. J Phys Chem B 2020; 124:11491-11500. [PMID: 33284009 DOI: 10.1021/acs.jpcb.0c09266] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Dielectric spectroscopy (DS) can be a robust in situ technique for geochemical applications. In this study, we applied deep-learning techniques to DS measurement data to enable rapid science interrogation and identification of electrolyte solutions containing salts and amino acids over a wide temperature range (20 to -60 °C). For the purpose of searching for signs of life, detecting amino acids is a fundamental high priority for field and planetary instruments as amino acids are one of the building blocks for life as we know it. A convolutional neural network (CNN) with channel-wise one-dimensional filters is proposed to fulfill the task, using the DS data of amino acid and inorganic salt solutions. Experimental results show that the CNN with two convolutional layers and one fully connected layer can effectively differentiate solutions containing amino acids from those containing salts in both the liquid and solid (water ice) states. To complement the experimental measurements and CNN analysis, the diffusive behaviors of ions (K+, Cl-, and OH-) were further discussed with atomistic molecular dynamics simulations performed in this work as well as the quantum simulation published in the literature. Combining DS with machine-learning techniques and simulations will greatly facilitate more real-time decision-making of mobility systems for future exploratory endeavors in other worlds beyond Earth.
Collapse
Affiliation(s)
- Yong Wei
- Department of Computer Science and Information Systems, University of North Georgia, Dahlonega, Georgia 30597, United States
| | - Keith Chin
- NASA Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California 91109, United States
| | - Laura M Barge
- NASA Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California 91109, United States
| | - Scott Perl
- NASA Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California 91109, United States
| | - Ninos Hermis
- NASA Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California 91109, United States
| | - Tao Wei
- Chemical Engineering Department, Howard University, Washington, D.C. 20059, United States
| |
Collapse
|
17
|
Tolouei NE, Ghamari S, Shavezipur M. Development of circuit models for electrochemical impedance spectroscopy (EIS) responses of interdigitated MEMS biochemical sensors. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114598] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
18
|
Salvo P, Vivaldi FM, Bonini A, Biagini D, Bellagambi FG, Miliani FM, Di Francesco F, Lomonaco T. Biosensors for Detecting Lymphocytes and Immunoglobulins. BIOSENSORS 2020; 10:E155. [PMID: 33121071 PMCID: PMC7694141 DOI: 10.3390/bios10110155] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 10/23/2020] [Accepted: 10/26/2020] [Indexed: 12/15/2022]
Abstract
Lymphocytes (B, T and natural killer cells) and immunoglobulins are essential for the adaptive immune response against external pathogens. Flow cytometry and enzyme-linked immunosorbent (ELISA) kits are the gold standards to detect immunoglobulins, B cells and T cells, whereas the impedance measurement is the most used technique for natural killer cells. For point-of-care, fast and low-cost devices, biosensors could be suitable for the reliable, stable and reproducible detection of immunoglobulins and lymphocytes. In the literature, such biosensors are commonly fabricated using antibodies, aptamers, proteins and nanomaterials, whereas electrochemical, optical and piezoelectric techniques are used for detection. This review describes how these measurement techniques and transducers can be used to fabricate biosensors for detecting lymphocytes and the total content of immunoglobulins. The various methods and configurations are reported, along with the advantages and current limitations.
Collapse
Affiliation(s)
- Pietro Salvo
- Institute of Clinical Physiology, National Council of Research, Via Moruzzi 1, 56124 Pisa, Italy;
| | - Federico M. Vivaldi
- Institute of Clinical Physiology, National Council of Research, Via Moruzzi 1, 56124 Pisa, Italy;
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Moruzzi 13, 56124 Pisa, Italy; (A.B.); (D.B.); (F.M.M.); (F.D.F.); (T.L.)
| | - Andrea Bonini
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Moruzzi 13, 56124 Pisa, Italy; (A.B.); (D.B.); (F.M.M.); (F.D.F.); (T.L.)
| | - Denise Biagini
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Moruzzi 13, 56124 Pisa, Italy; (A.B.); (D.B.); (F.M.M.); (F.D.F.); (T.L.)
| | - Francesca G. Bellagambi
- Institut des Sciences Analytiques, UMR 5280, Université Lyon 1, 5, rue de la Doua, 69100 Villeurbanne, France;
| | - Filippo M. Miliani
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Moruzzi 13, 56124 Pisa, Italy; (A.B.); (D.B.); (F.M.M.); (F.D.F.); (T.L.)
| | - Fabio Di Francesco
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Moruzzi 13, 56124 Pisa, Italy; (A.B.); (D.B.); (F.M.M.); (F.D.F.); (T.L.)
| | - Tommaso Lomonaco
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Moruzzi 13, 56124 Pisa, Italy; (A.B.); (D.B.); (F.M.M.); (F.D.F.); (T.L.)
| |
Collapse
|
19
|
Adhikari J, Rizwan M, Koh D, Keasberry NA, Ahmed MU. Electrochemical Study of Dimensional Specific Carbon Nanomaterials Modified Glassy Carbon Electrode for Highly Sensitive Label-free Detection of Immunoglobulin A. CURR ANAL CHEM 2020. [DOI: 10.2174/1573411015666190925152124] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
Immunoglobulin A (IgA) accounts for 15% of total protein production per
day and plays a crucial role in the first-line immune defence. Recently, IgA has been established as a
vital clinical biomarker for nephropathy, allergic asthma, celiac disease (CD), pneumonia, and asthma
as well as some neurological disorders. In this work, we have studied several carbon nanomaterials
(CNMs) having different dimensions (D): carbon nano-onions (CNOs) - 0D, single-walled carbon
nanotubes (SWCNTs) - 1D, and graphene nanoplatelets (GNPs) - 2D, on glassy carbon electrode
(GCE) to identify which CNMs (CNOs/SWCNTs/GNPs) work best to fabricate IgA based electrochemical
immunosensor.
Methods:
Different CNMs (CNOs, SWCNTs, GNPs) were tested for high electric current on GCE
using square wave voltammetry (SWV), and among them, GNPs modified GCE platform
(GNPs/GCE) showcased the highest electric current. Therefore, GNPs/GCE was utilized for the development
of highly sensitive label-free electrochemical immunosensor for the detection of Immunoglobulin
A using SWV.
Results:
Despite the simple fabrication strategies employed, the fabricated sensor demonstrated a
low limit of detection of 50 fg mL-1 with an extensive linear range of detection from 50 fg mL-1 to
0.1 μg mL-1.
Conclusion:
Fabricated immunosensor represented high stability, repeatability, specificity and resistance
to most common interferences as well as great potential to analyse the real sample.
Collapse
Affiliation(s)
- Juthi Adhikari
- Faculty of Science, Biosensors and Biotechnology Laboratory, Chemical Science Programme, Universiti Brunei Darussalam. Jalan Tungku Link, Gadong, BE 1410, Brunei, Brunei Darussalam
| | - Mohammad Rizwan
- Faculty of Science, Biosensors and Biotechnology Laboratory, Chemical Science Programme, Universiti Brunei Darussalam. Jalan Tungku Link, Gadong, BE 1410, Brunei, Brunei Darussalam
| | - David Koh
- PAPRSB Institute of Health Sciences, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong, BE 1410, Brunei Darussalam
| | - Natasha Ann Keasberry
- Faculty of Science, Biosensors and Biotechnology Laboratory, Chemical Science Programme, Universiti Brunei Darussalam. Jalan Tungku Link, Gadong, BE 1410, Brunei, Brunei Darussalam
| | - Minhaz Uddin Ahmed
- Faculty of Science, Biosensors and Biotechnology Laboratory, Chemical Science Programme, Universiti Brunei Darussalam. Jalan Tungku Link, Gadong, BE 1410, Brunei, Brunei Darussalam
| |
Collapse
|
20
|
Kulikova T, Gorbatchuk V, Stoikov I, Rogov A, Evtugyn G, Hianik T. Impedimetric Determination of Kanamycin in Milk with Aptasensor Based on Carbon Black-Oligolactide Composite. SENSORS 2020; 20:s20174738. [PMID: 32839389 PMCID: PMC7506709 DOI: 10.3390/s20174738] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 08/10/2020] [Accepted: 08/20/2020] [Indexed: 12/13/2022]
Abstract
The determination of antibiotics in food is important due to their negative effect on human health related to antimicrobial resistance problem, renal toxicity, and allergic effects. We propose an impedimetric aptasensor for the determination of kanamycin A (KANA), which was assembled on the glassy carbon electrode by the deposition of carbon black in a chitosan matrix followed by carbodiimide binding of aminated aptamer mixed with oligolactide derivative of thiacalix[4]arene in a cone configuration. The assembling was monitored by cyclic voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy. In the presence of the KANA, the charge transfer resistance of the inner interface surprisingly decreased with the analyte concentration within 0.7 and 50 nM (limit of detection 0.3 nM). This was attributed to the partial shielding of the negative charge of the aptamer and of its support, a highly porous 3D structure of the surface layer caused by a macrocyclic core of the carrier. The use of electrostatic assembling in the presence of cationic polyelectrolyte decreased tenfold the detectable concentration of KANA. The aptasensor was successfully tested in the determination of KANA in spiked milk and yogurt with recoveries within 95% and 115%.
Collapse
Affiliation(s)
- Tatiana Kulikova
- A.M. Butlerov’ Chemistry Institute of Kazan Federal University, 420008 Kazan, Russia; (T.K.); (V.G.); (I.S.)
| | - Vladimir Gorbatchuk
- A.M. Butlerov’ Chemistry Institute of Kazan Federal University, 420008 Kazan, Russia; (T.K.); (V.G.); (I.S.)
| | - Ivan Stoikov
- A.M. Butlerov’ Chemistry Institute of Kazan Federal University, 420008 Kazan, Russia; (T.K.); (V.G.); (I.S.)
| | - Alexey Rogov
- Interdisciplinary Center of Analytical Microscopy of Kazan Federal University, 420008 Kazan, Russia;
| | - Gennady Evtugyn
- A.M. Butlerov’ Chemistry Institute of Kazan Federal University, 420008 Kazan, Russia; (T.K.); (V.G.); (I.S.)
- Analytical Chemistry Department, Chemical Technology Institute, Ural Federal University, 620002 Ekaterinburg, Russia
- Correspondence: (G.E.); (T.H.); Tel.: +7-843-2337491 (G.E.); +421-2-60295683 (T.H.)
| | - Tibor Hianik
- Department of Nuclear Physics and Biophysics, Comenius University, 842 48 Bratislava, Slovakia
- Correspondence: (G.E.); (T.H.); Tel.: +7-843-2337491 (G.E.); +421-2-60295683 (T.H.)
| |
Collapse
|
21
|
Bhardwaj H, Marquette CA, Dutta P, Rajesh, Sumana G. Integrated graphene quantum dot decorated functionalized nanosheet biosensor for mycotoxin detection. Anal Bioanal Chem 2020; 412:7029-7041. [DOI: 10.1007/s00216-020-02840-0] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 07/03/2020] [Accepted: 07/23/2020] [Indexed: 12/17/2022]
|
22
|
Osaki S, Wakida SI, Saito M, Tamiya E. Towards On-site Determination of Secretory IgA in Artificial Saliva with Gold-Linked Electrochemical Immunoassay (GLEIA) Using Portable Potentiostat and Disposable Printed Electrode. Appl Biochem Biotechnol 2020; 193:1311-1320. [PMID: 32535815 DOI: 10.1007/s12010-020-03332-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Accepted: 04/23/2020] [Indexed: 11/24/2022]
Abstract
Mental stress is closely connected with our physical and mental wellness. Therefore, stress measurement can contribute to assess our lifestyle and increase our quality of life. In this paper, we detect the secretory immunoglobulin A (sIgA), which is the candidate of salivary stress markers, with original electrochemical immunoassay: gold-linked electrochemical immunoassay (GLEIA). This biosensor is based on a sandwich-type immunosensor and adopts the electrochemical method to detect the reduction peak from Au nanoparticles linked to the secondary antibody. GLEIA is convenient and cost-effective that only requires a low sample volume (10 μL). In addition, the GLEIA show high sensitivity and selectivity. We obtained the linear response to relate the concentration of sIgA (10-300 ng/mL) in D-PBS buffer with the artificial saliva which includes salivary inorganic salt and typically glycoprotein (mucin). Furthermore, we obtained acceptable selectivity in the various solution with salivary proteins such as α-amylase, human serum albumin, immunoglobulin G (IgG), lysozyme, and mucin. In the future, we try to detect the sIgA in real saliva for on-site stress measurement using GLEIA and to integrate the various immunosensors for stress markers in saliva.
Collapse
Affiliation(s)
- Shuto Osaki
- AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory, AIST, Suita, Japan.,Graduate School of Engineering, Osaka University, Suita, Japan
| | - Shin-Ichi Wakida
- AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory, AIST, Suita, Japan.,Graduate School of Engineering, Osaka University, Suita, Japan.,Graduate School of Human Development and Environment, Kobe University, Kobe, Japan
| | - Masato Saito
- AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory, AIST, Suita, Japan.,Graduate School of Engineering, Osaka University, Suita, Japan
| | - Eiichi Tamiya
- AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory, AIST, Suita, Japan. .,Graduate School of Engineering, Osaka University, Suita, Japan.
| |
Collapse
|
23
|
An Impedance Sensor in Detection of Immunoglobulin G with Interdigitated Electrodes on Flexible Substrate. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10114012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Immunoassay plays an important role in the early screening and diagnosis of diseases. The use of electrochemical methods to realize the label-free, specific and rapid detection of antigens has attracted extensive attention from researchers. In this study, we realized the function of immunosensing and detection by lithography, the interdigitated gold electrode on the polyethylene naphthalate (PEN) membrane. Then, the gold electrode was biofunctionalized and the characterization was verified by atomic force microscopy, which was finally for the detection of mice IgG. This immunosensor has a low detection limit, with a broad linear detection range of 0.01–10 ng/mL. The results show that the electrochemical impedance sensor made of metal electrodes based on PEN flexible materials is suitable for immunoassay experiments. If this method could be proved by further studies, broad application prospects can be seen in routine immunoassays.
Collapse
|
24
|
Gopinath SCB, Xuan S. DNA-RNA complementation on silicon wafer for thyroid cancer determination. Biotechnol Appl Biochem 2020; 68:554-559. [PMID: 32460382 DOI: 10.1002/bab.1961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Accepted: 05/24/2020] [Indexed: 11/07/2022]
Abstract
One of the current issues with thyroid tumor is early diagnosis as it makes the higher possibility of curing. This research was focused to detect and quantify the level of specific target sequence complementation of miR-222 with capture DNA sequence on interdigitated electrode (IDE) sensor. The aluminum electrode with the gap and finger sizes of 10 µm was fabricated on silicon wafer, further the surface was amine-functionalized for accommodating carboxylated-DNA probe. With DNA-target RNA complementation, the detection limit was attained to be 1 fM as estimated by a linear regression analysis [y = 1.5325x - 2.1171 R² = 0.9065] and the sensitivity was at the similar level. Current responses were higher by increasing the target RNA sequence concentrations. Control experiments with mismatched/noncomplementary sequences were failed to complement the capture DNA sequence immobilized on IDE, indicating the specific target validation. This research helps diagnosing and identifying the progression with thyroid tumor and miRNA being a potential "marker" in atypia diagnosis.
Collapse
Affiliation(s)
- Subash C B Gopinath
- School of Bioprocess Engineering, Arau, Perlis, Malaysia.,Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, Kangar, Perlis, Malaysia
| | - Shijin Xuan
- Department of Mammary and Thyroid Surgery, Central Hospital Affiliated to Shandong First Medical University, Jinan, 250013, China
| |
Collapse
|
25
|
Lai CY, Huang WC, Weng JH, Chen LC, Chou CF, Wei PK. Impedimetric aptasensing using a symmetric Randles circuit model. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.135750] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
26
|
Lai CY, Weng JH, Shih WL, Chen LC, Chou CF, Wei PK. Diffusion impedance modeling for interdigitated array electrodes by conformal mapping and cylindrical finite length approximation. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2019.134629] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
27
|
Li D, Batchelor-McAuley C, Chen L, Compton RG. Band Electrodes in Sensing Applications: Response Characteristics and Band Fabrication Methods. ACS Sens 2019; 4:2250-2266. [PMID: 31407573 DOI: 10.1021/acssensors.9b01172] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
This Review surveys the fabrication methods reported for both single microband electrodes and microband electrode arrays and their uses in sensing applications. A theoretical section on band electrodes provides background information on the structure of band electrodes, their diffusional profiles, and the types of voltammetric behavior observed. A short section summarizes the currently available commercial microband electrodes. A section describing recent (10 years) sensing applications using band electrode is also presented.
Collapse
Affiliation(s)
- Danlei Li
- Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| | - Christopher Batchelor-McAuley
- Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| | - Lifu Chen
- Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| | - Richard G. Compton
- Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| |
Collapse
|
28
|
Congur G, Erdem A. PAMAM dendrimer modified screen printed electrodes for impedimetric detection of miRNA-34a. Microchem J 2019. [DOI: 10.1016/j.microc.2019.05.040] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
29
|
Taniselass S, Arshad MM, Gopinath SC. Graphene-based electrochemical biosensors for monitoring noncommunicable disease biomarkers. Biosens Bioelectron 2019; 130:276-292. [DOI: 10.1016/j.bios.2019.01.047] [Citation(s) in RCA: 134] [Impact Index Per Article: 26.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2018] [Revised: 01/16/2019] [Accepted: 01/18/2019] [Indexed: 02/07/2023]
|
30
|
Chen Z, Wang C, Hao L, Gao R, Li F, Liu S. Proximity recognition and polymerase-powered DNA walker for one-step and amplified electrochemical protein analysis. Biosens Bioelectron 2019; 128:104-112. [DOI: 10.1016/j.bios.2018.12.053] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Revised: 12/27/2018] [Accepted: 12/28/2018] [Indexed: 12/20/2022]
|
31
|
Panneer Selvam A, Prasad S. Companion and Point-of-Care Sensor System for Rapid Multiplexed Detection of a Panel of Infectious Disease Markers. SLAS Technol 2018; 22:338-347. [PMID: 28520525 DOI: 10.1177/2211068217696779] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
A nanochannel-based electrochemical biosensor has been demonstrated for rapid and multiplexed detection of a panel of three biomarkers associated with rapid detection of sepsis. The label-free biosensor detected procalcitonin (PCT), lipoteichoic acid (LTA), and lipopolysaccharide (LPS) from human whole blood. The biosensor comprises a nanoporous nylon membrane integrated onto a microelectrode sensor platform for nanoconfinement effects. Charge perturbations due to biomarker binding are recorded as impedance changes using electrochemical impedance spectroscopy. The measured impedance change is used to quantitatively determine the concentration of the three biomarkers using antibody receptors from the tested sample. We were successful in detecting and quantifying the three biomarkers from whole blood. The limit of detection was 0.1 ng/mL for PCT and 1 µg/mL for LPS and LTA. The sensor was able to demonstrate a dynamic range of detection from 01.1 ng/mL to 10 µg/mL for PCT and from 1 µg/mL to 1000 µg/mL for LPS and LTA biomarkers. This novel technology has promising preliminary results toward the design of sensors for rapid and sensitive detection of the three panel biomarkers in whole blood toward diagnosis and classification of sepsis.
Collapse
Affiliation(s)
- Anjan Panneer Selvam
- 1 Department of Bioengineering, University of Texas at Dallas, Richardson, TX, USA
| | - Shalini Prasad
- 1 Department of Bioengineering, University of Texas at Dallas, Richardson, TX, USA
| |
Collapse
|
32
|
Abstract
Hormones produced by glands in the endocrine system and neurotransmitters produced by the nervous system control many bodily functions. The concentrations of these molecules in the body are an indication of its state, hence the use of the term biomarker. Excess concentrations of biomarkers, such as cortisol, serotonin, epinephrine, and dopamine, are released by the body in response to a variety of conditions, for example, emotional state (euphoria, stress) and disease. The development of simple, low-cost modalities for point-of-use (PoU) measurements of biomarkers levels in various bodily fluids (blood, urine, sweat, saliva) as opposed to conventional hospital or lab settings is receiving increasing attention. This paper starts with a review of the basic properties of 12 primary stress-induced biomarkers: origin in the body (i.e., if they are produced as hormones, neurotransmitters, or both), chemical composition, molecular weight (small/medium size molecules and polymers, ranging from ∼100 Da to ∼100 kDa), and hydro- or lipophilic nature. Next is presented a detailed review of the published literature regarding the concentration of these biomarkers found in several bodily fluids that can serve as the medium for determination of the condition of the subject: blood, urine, saliva, sweat, and, to a lesser degree, interstitial tissue fluid. The concentration of various biomarkers in most fluids covers a range of 5-6 orders of magnitude, from hundreds of nanograms per milliliter (∼1 μM) down to a few picograms per milliliter (sub-1 pM). Mechanisms and materials for point-of-use biomarker sensors are summarized, and key properties are reviewed. Next, selected methods for detecting these biomarkers are reviewed, including antibody- and aptamer-based colorimetric assays and electrochemical and optical detection. Illustrative examples from the literature are discussed for each key sensor approach. Finally, the review outlines key challenges of the field and provides a look ahead to future prospects.
Collapse
Affiliation(s)
- Andrew J. Steckl
- Nanoelectronics Laboratory, University of Cincinnati, Cincinnati, Ohio 45221-0030, United States
| | - Prajokta Ray
- Nanoelectronics Laboratory, University of Cincinnati, Cincinnati, Ohio 45221-0030, United States
| |
Collapse
|
33
|
Ding S, Das SR, Brownlee BJ, Parate K, Davis TM, Stromberg LR, Chan EK, Katz J, Iverson BD, Claussen JC. CIP2A immunosensor comprised of vertically-aligned carbon nanotube interdigitated electrodes towards point-of-care oral cancer screening. Biosens Bioelectron 2018; 117:68-74. [DOI: 10.1016/j.bios.2018.04.016] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Accepted: 04/07/2018] [Indexed: 11/28/2022]
|
34
|
Bertok T, Lorencova L, Chocholova E, Jane E, Vikartovska A, Kasak P, Tkac J. Electrochemical Impedance Spectroscopy Based Biosensors: Mechanistic Principles, Analytical Examples and Challenges towards Commercialization for Assays of Protein Cancer Biomarkers. ChemElectroChem 2018. [DOI: 10.1002/celc.201800848] [Citation(s) in RCA: 86] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Tomas Bertok
- Department of Glycobiotechnology Institution of ChemistrySlovak Academy of Sciences Dubravska cesta 9 845 38 Bratislava Slovakia
| | - Lenka Lorencova
- Department of Glycobiotechnology Institution of ChemistrySlovak Academy of Sciences Dubravska cesta 9 845 38 Bratislava Slovakia
| | - Erika Chocholova
- Department of Glycobiotechnology Institution of ChemistrySlovak Academy of Sciences Dubravska cesta 9 845 38 Bratislava Slovakia
| | - Eduard Jane
- Department of Glycobiotechnology Institution of ChemistrySlovak Academy of Sciences Dubravska cesta 9 845 38 Bratislava Slovakia
| | - Alica Vikartovska
- Department of Glycobiotechnology Institution of ChemistrySlovak Academy of Sciences Dubravska cesta 9 845 38 Bratislava Slovakia
| | - Peter Kasak
- Center for Advanced MaterialsQatar University Doha 2713 Qatar
| | - Jan Tkac
- Department of Glycobiotechnology Institution of ChemistrySlovak Academy of Sciences Dubravska cesta 9 845 38 Bratislava Slovakia
| |
Collapse
|
35
|
Film bulk acoustic resonators (FBARs) as biosensors: A review. Biosens Bioelectron 2018; 116:1-15. [DOI: 10.1016/j.bios.2018.05.028] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Revised: 05/08/2018] [Accepted: 05/16/2018] [Indexed: 01/01/2023]
|
36
|
Ong CC, Gopinath SCB, Rebecca LWX, Perumal V, Lakshmipriya T, Saheed MSM. Diagnosing human blood clotting deficiency. Int J Biol Macromol 2018; 116:765-773. [PMID: 29775720 DOI: 10.1016/j.ijbiomac.2018.05.084] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2018] [Revised: 05/13/2018] [Accepted: 05/14/2018] [Indexed: 11/19/2022]
Abstract
There are different clotting factors present in blood, carries the clotting cascade and excessive bleeding may cause a deficiency in the clotting Diagnosis of this deficiency in clotting drastically reduces the potential fatality. For enabling a sensor to detect the clotting factors, suitable probes such as antibody and aptamer have been used to capture these targets on the sensing surface. Two major clotting factors were widely studied for the diagnosis of clotting deficiency, which includes factor IX and thrombin. In addition, factor IX is considered as the substitute for heparin and the prothrombotic associated with the increased thrombin generation are taking into account their prevalence. The biosensors, surface plasmon resonance, evanescent-field-coupled waveguide-mode sensor, metal-enhanced PicoGreen fluorescence and electrochemical aptasensor were well-documented and improvements have been made for high-performance sensing. We overviewed detecting factor IX and thrombin using these biosensors, for the potential application in medical diagnosis.
Collapse
Affiliation(s)
- Chong Cheen Ong
- Department of Fundamental & Applied Science, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia.; Centre of Innovative Nanostructure & Nanodevices (COINN), Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia
| | - Subash C B Gopinath
- School of Bioprocess Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia; Institute of Nano Electronic Engineering, University Malaysia Perlis, 01000 Kangar, Perlis, Malaysia.
| | - Leong Wei Xian Rebecca
- Department of Fundamental & Applied Science, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia.; Centre of Innovative Nanostructure & Nanodevices (COINN), Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia
| | - Veeradasan Perumal
- Centre of Innovative Nanostructure & Nanodevices (COINN), Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia; Department of Mechanical Engineering, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia
| | - Thangavel Lakshmipriya
- Centre of Innovative Nanostructure & Nanodevices (COINN), Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia
| | - Mohamed Shuaib Mohamed Saheed
- Department of Fundamental & Applied Science, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia.; Centre of Innovative Nanostructure & Nanodevices (COINN), Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia
| |
Collapse
|
37
|
Chin KB, Chi I, Pasalic J, Huang CK, Barge LM. An introductory study using impedance spectroscopy technique with polarizable microelectrode for amino acids characterization. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:045108. [PMID: 29716330 DOI: 10.1063/1.5020076] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Portable, low power, yet ultra-sensitive life detection instrumentations are vital to future astrobiology flight programs at NASA. In this study, initial attempts to characterize amino acids in an aqueous environment by electrochemical impedance spectroscopy (EIS) using polarizable (blocking) electrodes in order to establish a means of detection via their electrical properties. Seven amino acids were chosen due to their scientific importance in demonstrating sensitivity levels in the range of part per billion concentration. Albeit more challenging in real systems of analyst mixtures, we found individual amino acids in aqueous environment do exhibit some degree of chemical and physical uniqueness to warrant characterization by EIS. The polar amino acids (Asp, Glu, and His) exhibited higher electrochemical activity than the non-polar amino acids (Ala, Gly, Val, and Leu). The non-polar amino acids (Gly and Ala) also exhibited unique electrical properties which appeared to be more dependent on physical characteristics such as molecular weight and structure. At concentrations above 1 mM where the amino acids play a more dominant transport role within the water, the conductivity was found to be more sensitive to concentrations. At lower concentrations <1 mM, however, the polar amino acid solution conductivity remained constant, suggesting poor chemical activity with water. As revealed by equivalent circuit modeling, the relaxation times showed a 1-2 order of magnitude difference between polar and non-polar amino acids. The pseudo-capacitance from EIS measurements on sample mixtures containing salt water and individual amino acids revealed the possibility for improvement in amino acid selectivity using gold nanoporous surface enhanced electrodes. This work establishes important methodologies for characterizing amino acids using EIS combined with microscale electrodes, supporting the case for instrumentation development for life detection and origin of life programs.
Collapse
Affiliation(s)
- K B Chin
- NASA Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California 91109, USA
| | - I Chi
- NASA Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California 91109, USA
| | - J Pasalic
- NASA Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California 91109, USA
| | - C-K Huang
- NASA Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California 91109, USA
| | - Laura M Barge
- NASA Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California 91109, USA
| |
Collapse
|
38
|
Determination of degree of RBC agglutination for blood typing using a small quantity of blood sample in a microfluidic system. Biosens Bioelectron 2018; 102:234-241. [DOI: 10.1016/j.bios.2017.11.008] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2017] [Revised: 10/15/2017] [Accepted: 11/01/2017] [Indexed: 12/11/2022]
|
39
|
Lim MP, Guo X, Grunblatt EL, Clifton GM, Gonzalez AN, LaFratta CN. Augmenting mask-based lithography with direct laser writing to increase resolution and speed. OPTICS EXPRESS 2018; 26:7085-7090. [PMID: 29609394 DOI: 10.1364/oe.26.007085] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Accepted: 01/26/2018] [Indexed: 05/23/2023]
Abstract
A new method of hybrid photolithography, Laser Augmented Microlithographic Patterning (LAMP), is described in which direct laser writing is used to define additional features to those made with an inexpensive transparency mask. LAMP was demonstrated with both positive- and negative-tone photoresists, S1813 and SU-8, respectively. The laser written features, which can have sub-micron linewidths, can be registered to within 2.2 µm of the mask created features. Two example structures, an interdigitated electrode and a microfluidic device that can capture an array of dozens of silica beads or living cells, are described. This combination of direct laser writing and conventional UV lithography compensates for the drawbacks of each method, and enables high resolution prototypes to be created, tested, and modified quickly.
Collapse
|
40
|
Jin WW, Li HJ, Zou JZ, Zeng SZ, Li QD, Xu GZ, Sheng HC, Wang BB, Si YH, Yu L, Zeng XR. Conducting polymer-coated MIL-101/S composite with scale-like shell structure for improving Li–S batteries. RSC Adv 2018; 8:4786-4793. [PMID: 35539531 PMCID: PMC9077768 DOI: 10.1039/c7ra12800b] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Accepted: 12/22/2017] [Indexed: 01/14/2023] Open
Abstract
Lithium–sulfur batteries are regarded as a promising energy storage system. However, they are plagued by rapid capacity decay, low coulombic efficiency, a severe shuttle effect and low sulfur loading in cathodes. To address these problems, effective carriers are highly demanded to encapsulate sulfur in order to extend the cycle life. Herein, we introduced a doped-PEDOT:PSS-coated MIL-101/S multi-core–shell structured composite. The unique structure of MIL-101, large specific area and conductive shell ensure high dispersion of sulfur in the composite and minimize the loss of polysulfides to the electrolyte. The doped-PEDOT:PSS-coated sulfur electrodes exhibited an increase in initial capacity and an improvement in rate characteristics. After 192 cycles at the current density of 0.1C, a doped-PEDOT:PSS-coated MIL-101/S electrode maintained a capacity of 606.62 mA h g−1, while the MIL-101/S@PEDOT:PSS electrode delivered a capacity of 456.69 mA h g−1. The EIS measurement revealed that the surface modification with the conducting polymer provided a lower resistance to the sulfur electrode, which resulted in better electrochemical behaviors in Li–S battery applications. Test results indicate that the MIL-101/S@doped-PEDOT:PSS is a promising host material for the sulfur cathode in the lithium–sulfur battery applications. Lithium–sulfur batteries are regarded as a promising energy storage system.![]()
Collapse
|
41
|
Muñoz J, Montes R, Baeza M. Trends in electrochemical impedance spectroscopy involving nanocomposite transducers: Characterization, architecture surface and bio-sensing. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2017.08.012] [Citation(s) in RCA: 90] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
42
|
Measurement of Impedimetric Ratio of Blood Cells Using Microfluidic Chip with ZnO Nanowires. J Med Biol Eng 2017. [DOI: 10.1007/s40846-017-0333-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
43
|
Panneer Selvam A, Prasad S. Companion and Point-of-Care Sensor System for Rapid Multiplexed Detection of a Panel of Infectious Disease Markers. SLAS Technol 2017. [DOI: 10.1177/2472630317696779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
A nanochannel-based electrochemical biosensor has been demonstrated for rapid and multiplexed detection of a panel of three biomarkers associated with rapid detection of sepsis. The label-free biosensor detected procalcitonin (PCT), lipoteichoic acid (LTA), and lipopolysaccharide (LPS) from human whole blood. The biosensor comprises a nanoporous nylon membrane integrated onto a microelectrode sensor platform for nanoconfinement effects. Charge perturbations due to biomarker binding are recorded as impedance changes using electrochemical impedance spectroscopy. The measured impedance change is used to quantitatively determine the concentration of the three biomarkers using antibody receptors from the tested sample. We were successful in detecting and quantifying the three biomarkers from whole blood. The limit of detection was 0.1 ng/mL for PCT and 1 µg/mL for LPS and LTA. The sensor was able to demonstrate a dynamic range of detection from 01.1 ng/mL to 10 µg/mL for PCT and from 1 µg/mL to 1000 µg/mL for LPS and LTA biomarkers. This novel technology has promising preliminary results toward the design of sensors for rapid and sensitive detection of the three panel biomarkers in whole blood toward diagnosis and classification of sepsis.
Collapse
Affiliation(s)
- Anjan Panneer Selvam
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX, USA
| | - Shalini Prasad
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX, USA
| |
Collapse
|
44
|
Ding S, Mosher C, Lee XY, Das SR, Cargill AA, Tang X, Chen B, McLamore ES, Gomes C, Hostetter JM, Claussen JC. Rapid and Label-Free Detection of Interferon Gamma via an Electrochemical Aptasensor Comprising a Ternary Surface Monolayer on a Gold Interdigitated Electrode Array. ACS Sens 2017; 2:210-217. [PMID: 28723140 DOI: 10.1021/acssensors.6b00581] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A label-free electrochemical impedance spectroscopy (EIS) aptasensor for rapid detection (<35 min) of interferon-gamma (IFN-γ) was fabricated by immobilizing a RNA aptamer capture probe (ACP), selective to IFN-γ, on a gold interdigitated electrode array (Au IDE). The ACP was modified with a thiol group at the 5' terminal end and subsequently co-immobilized with 1,6-hexanedithiol (HDT) and 6-mercapto-1-hexanolphosphate (MCH) to the gold surface through thiol-gold interactions. This ACP/HDT-MCH ternary surface monolayer facilitates efficient hybridization with IFN-γ and displays high resistance to nonspecific adsorption of nontarget proteins [i.e., fetal bovine serum (FBS) and bovine serum albumin (BSA)]. The Au IDE functionalized with ACP/HDT-MCH was able to measure IFN-γ in actual FBS solution with a linear sensing range from 22.22 pM to 0.11 nM (1-5 ng/mL) and a detection limit of 11.56 pM. The ability to rapidly sense IFN-γ within this sensing range makes the developed electrochemical platform conducive toward in-field disease detection of a variety of diseases including paratuberculosis (i.e., Johne's Disease). Furthermore, experimental results were numerically validated with an equivalent circuit model that elucidated the effects of the sensing process and the influence of the immobilized ternary monolayer on signal output. This is the first time that ternary surface monolayers have been used to selectively capture/detect IFN-γ on Au IDEs.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Eric S. McLamore
- Agriculture
and Biological Engineering Department, Institute of Food and Agricultural
Sciences, University of Florida, Gainesville, Florida 32611, United States
| | - Carmen Gomes
- Biological and Agricultural Engineering Department, Texas A&M University, College Station, Texas 77843, United States
| | | | | |
Collapse
|
45
|
Cecchetto J, Fernandes FC, Lopes R, Bueno PR. The capacitive sensing of NS1 Flavivirus biomarker. Biosens Bioelectron 2017; 87:949-956. [DOI: 10.1016/j.bios.2016.08.097] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2016] [Revised: 08/26/2016] [Accepted: 08/28/2016] [Indexed: 02/05/2023]
|
46
|
Aptamer-based impedimetric determination of the human blood clotting factor IX in serum using an interdigitated electrode modified with a ZnO nanolayer. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-2001-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
47
|
Sun A, Venkatesh AG, Hall DA. A Multi-Technique Reconfigurable Electrochemical Biosensor: Enabling Personal Health Monitoring in Mobile Devices. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2016; 10:945-954. [PMID: 28113176 DOI: 10.1109/tbcas.2016.2586504] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This paper describes the design and characterization of a reconfigurable, multi-technique electrochemical biosensor designed for direct integration into smartphone and wearable technologies to enable remote and accurate personal health monitoring. By repurposing components from one mode to the next, the biosensor's potentiostat is able reconfigure itself into three different measurements modes to perform amperometric, potentiometric, and impedance spectroscopic tests all with minimal redundant devices. A [Formula: see text] PCB prototype of the module was developed with discrete components and tested using Google's Project Ara modular smartphone. The amperometric mode has a ±1 nA to [Formula: see text] measurement range. When used to detect pH, the potentiometric mode achieves a resolution of < 0.08 pH units. In impedance measurement mode, the device can measure 50 Ω-10 [Formula: see text] and has been shown to have of phase error. This prototype was used to perform several point-of-care health tracking assays suitable for use with mobile devices: 1) Blood glucose tests were conducted and shown to cover the diagnostic range for Diabetic patients ( ∼ 200 mg/dL). 2) Lactoferrin, a biomarker for urinary tract infections, was detected with a limit of detection of approximately 1 ng/mL. 3) pH tests of sweat were conducted to track dehydration during exercise. 4) EIS was used to determine the concentration of NeutrAvidin via a label-free assay.
Collapse
|
48
|
Guryanov I, Fiorucci S, Tennikova T. Receptor-ligand interactions: Advanced biomedical applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 68:890-903. [PMID: 27524092 DOI: 10.1016/j.msec.2016.07.072] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2016] [Revised: 07/11/2016] [Accepted: 07/26/2016] [Indexed: 12/24/2022]
Abstract
Receptor-ligand interactions (RLIs) are at the base of all biological events occurring in living cells. The understanding of interactions between complementary macromolecules in biological systems represents a high-priority research area in bionanotechnology to design the artificial systems mimicking natural processes. This review summarizes and analyzes RLIs in some cutting-edge biomedical fields, in particular, for the preparation of novel stationary phases to separate complex biological mixtures in medical diagnostics, for the design of ultrasensitive biosensors for identification of biomarkers of various diseases at early stages, as well as in the development of innovative biomaterials and approaches for regenerative medicine. All these biotechnological fields are closely related, because their success depends on a proper choice, combination and spatial disposition of the single components of ligand-receptor pairs on the surface of appropriately designed support.
Collapse
Affiliation(s)
- Ivan Guryanov
- Institute of Chemistry, St. Petersburg State University, 198504 St. Petersburg, Russia.
| | - Stefano Fiorucci
- Department of Clinical and Experimental Medicine, University of Perugia, 06122 Perugia, Italy.
| | - Tatiana Tennikova
- Institute of Chemistry, St. Petersburg State University, 198504 St. Petersburg, Russia.
| |
Collapse
|
49
|
Afsarimanesh N, Zia AI, Mukhopadhyay SC, Kruger M, Yu PL, Kosel J, Kovacs Z. Smart Sensing System for the Prognostic Monitoring of Bone Health. SENSORS 2016; 16:s16070976. [PMID: 27347968 PMCID: PMC4970028 DOI: 10.3390/s16070976] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2016] [Revised: 06/21/2016] [Accepted: 06/22/2016] [Indexed: 02/04/2023]
Abstract
The objective of this paper is to report a novel non-invasive, real-time, and label-free smart assay technique for the prognostic detection of bone loss by electrochemical impedance spectroscopy (EIS). The proposed system incorporated an antibody-antigen-based sensor functionalization to induce selectivity for the C-terminal telopeptide type one collagen (CTx-I) molecules—a bone loss biomarker. Streptavidin agarose was immobilized on the sensing area of a silicon substrate-based planar sensor, patterned with gold interdigital electrodes, to capture the antibody-antigen complex. Calibration experiments were conducted with various known CTx-I concentrations in a buffer solution to obtain a reference curve that was used to quantify the concentration of an analyte in the unknown serum samples. Multivariate chemometric analyses were done to determine the performance viability of the developed system. The analyses suggested that a frequency of 710 Hz is the most discriminating regarding the system sensitivity. A detection limit of 0.147 ng/mL was achieved for the proposed sensor and the corresponding reference curve was linear in the range of 0.147 ng/mL to 2.669 ng/mL. Two sheep blood samples were tested by the developed technique and the results were validated using enzyme-linked immunosorbent assay (ELISA). The results from the proposed technique match those from the ELISA.
Collapse
Affiliation(s)
- Nasrin Afsarimanesh
- School of Engineering and Advanced Technology, Massey University, Palmerston North 4442, New Zealand.
| | - Asif I Zia
- School of Engineering and Advanced Technology, Massey University, Palmerston North 4442, New Zealand.
- Department of Physics, COMSATS Institute of Science and Technology, Islamabad 45550, Pakistan.
| | | | - Marlena Kruger
- Institute of Food Science and Technology, Massey University, Palmerston North 4442, New Zealand.
| | - Pak-Lam Yu
- School of Engineering and Advanced Technology, Massey University, Palmerston North 4442, New Zealand.
| | - Jurgen Kosel
- Sensing, Magnetism and Microsystems Group, King Abdullah University of Science and Technology, Thuwal 23955-6900, Saudi Arabia.
| | - Zoltan Kovacs
- Department of Physics and Control, Faculty of Food Science, Szent István University, Budapest H-1118, Hungary.
| |
Collapse
|
50
|
A new nano-worm structure from gold-nanoparticle mediated random curving of zinc oxide nanorods. Biosens Bioelectron 2016; 78:14-22. [DOI: 10.1016/j.bios.2015.10.083] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2015] [Revised: 10/16/2015] [Accepted: 10/28/2015] [Indexed: 10/22/2022]
|