1
|
Cortés-Avendaño P, Macavilca EA, Ponce-Rosas FC, Murillo-Baca SM, Quispe-Neyra J, Alvarado-Zambrano F, Condezo-Hoyos L. Microfluidic paper-based analytical device for measurement of pH using as sensor red cabbage anthocyanins and gum arabic. Food Chem 2025; 462:140964. [PMID: 39213972 DOI: 10.1016/j.foodchem.2024.140964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2024] [Revised: 08/10/2024] [Accepted: 08/21/2024] [Indexed: 09/04/2024]
Abstract
The objective of this study was to develop and validate a novel microfluidic paper-based analytical device (μPADpH) for determining the pH levels in foods. Anthocyanins from red cabbage aqueous extract (RCAE) were used as its analytical sensor. Whatman No. 1 filter paper was the most suitable for the device due to its porosity and fiber organization, which allows for maximum color intensity and minimal color heterogeneity of the RCAE in the detection zone of the μPADpH. To ensure the color stability of the RCAE for commercial use of the μPADpH, gum arabic was added. The geometric design of the μPADpH, including the channel length and separation zone diameter, was systematically optimized using colored food. The validation showed that the μPADpH did not differ from the pH meter when analyzing natural foods. However, certain additives in processed foods were found to increase the pH values.
Collapse
Affiliation(s)
- Paola Cortés-Avendaño
- Universidad Nacional Agraria La Molina, Facultad de Industrias Alimentarias, Innovative Technology, Food and Health Research Group, Lima, Peru; Universidad Nacional Agraria La Molina, Instituto de Investigación de Bioquímica y Biología Molecular, Lima, Peru
| | - Edwin A Macavilca
- Universidad Nacional Jose Faustino Sanchez Carrion, Departamento de Ingenieria en Industrias Alimentarias, Functional Food Research Laboratory, Huacho, Peru
| | - Fortunato C Ponce-Rosas
- Universidad Nacional Daniel Alcides Carrión, Facultad de Ciencias Agropecuarias. Escuela de Formación Profesional de Industrias Alimentarias, La Merced, Chanchamayo, Peru
| | - Silvia M Murillo-Baca
- Universidad Nacional Daniel Alcides Carrión, Facultad de Ciencias Agropecuarias. Escuela de Formación Profesional de Industrias Alimentarias, La Merced, Chanchamayo, Peru
| | - Juan Quispe-Neyra
- Universidad Nacional de Piura, Escuela Profesional de Ingeniería Agroindustrial e Industrias Alimentarias, Piura, Peru
| | - Fredy Alvarado-Zambrano
- Universidad Nacional Santiago Antúnez de Mayolo, Facultad de Ingenieria de Industrias Alimentarias, Huaraz, Peru
| | - Luis Condezo-Hoyos
- Universidad Nacional Agraria La Molina, Facultad de Industrias Alimentarias, Innovative Technology, Food and Health Research Group, Lima, Peru; Universidad Nacional Agraria La Molina, Instituto de Investigación de Bioquímica y Biología Molecular, Lima, Peru.
| |
Collapse
|
2
|
Strohmaier-Nguyen D, Horn C, Baeumner AJ. Innovations in one-step point-of-care testing within microfluidics and lateral flow assays for shaping the future of healthcare. Biosens Bioelectron 2025; 267:116795. [PMID: 39332251 DOI: 10.1016/j.bios.2024.116795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Revised: 08/31/2024] [Accepted: 09/17/2024] [Indexed: 09/29/2024]
Abstract
Point-of-care testing (POCT) technology, using lateral flow assays and microfluidic systems, facilitates cost-effective diagnosis, timely treatment, ongoing monitoring, and prevention of life-threatening outcomes. Aside from significant advancements demonstrated in academic research, implementation in real-world applications remains frustratingly limited. The divergence between academic developments and practical utility is often due to factors such as operational complexity, low sensitivity and the need for trained personnel. Taking this into consideration, our objective is to present a critical and objective overview of the latest advancements in fully integrated one-step POCT assays for home-testing which would be commercially viable. In particular, aspects of signal amplification, assay design modification, and sample preparation are critically evaluated and their features and medical applications along with future perspective and challenges with respect to minimal user intervention are summarized. Associated with and very important for the one-step POCT realization are also readout devices and fabrication processes. Critical analysis of available and useful technologies are presented in the SI section.
Collapse
Affiliation(s)
- Dan Strohmaier-Nguyen
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053, Regensburg, Germany
| | - Carina Horn
- Roche Diagnostics GmbH, 68305, Mannheim, Germany
| | - Antje J Baeumner
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053, Regensburg, Germany.
| |
Collapse
|
3
|
Chen J, Su Z, Li W, Pei Z, Wu D, Li L, Wu Y, Li G. A Clickase-Mediated Immunoassay Based on Nanopore and Bionic Signal Labels for Ultrasensitive, Portable, and On-Site Detection of Ricin. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2024; 72:25330-25339. [PMID: 39441662 DOI: 10.1021/acs.jafc.4c05406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2024]
Abstract
It is of particular importance to develop an effective method that possesses several merits simultaneously of rapid, ultrasensitive, portable, and on-site detection potential for food safety detection. Herein, we propose a clickase-mediated immunoassay based on nanopore and bionic signal labels for the detection of ricin. The introduction of Cu/Cys clickase and nanopore simultaneously effectively addressed the inherent limitations of natural enzymes and colorimetric signal output, respectively. Using this method, bionic signal labels can be easily formed through DNA and Gram-positive bacterial cell wall terminal peptide fragments (labeled by alkynyl and azide, respectively) and vancomycin. Translocation of the D-P@vancomycin through the nanopore generated highly specific oscillation current traces. This method showed a great on-site detection potential and superior analytical performance owing to the combination of the specificity of antibodies, high CuAAC click reaction catalytic efficiency of clickase, ultrasensitivity of the nanopore, and high signal resolution of D-P@vancomycin. Moreover, the practical applicability of the established method was also verified, achieving a limit of detection (LOD) down to 200.9 ag/mL with a wide linear relationship under the optimized conditions. In conclusion, this method is promising for rapid, portable, ultrasensitive, and on-site food safety detection.
Collapse
Affiliation(s)
- Jianing Chen
- School of Food Science and Engineering, Shaanxi University of Science and Technology, Xi'an 710021, China
| | - Zhuoqun Su
- School of Food Science and Engineering, Shaanxi University of Science and Technology, Xi'an 710021, China
| | - Wenrui Li
- School of Food Science and Engineering, Shaanxi University of Science and Technology, Xi'an 710021, China
| | - Ziye Pei
- School of Food Science and Engineering, Shaanxi University of Science and Technology, Xi'an 710021, China
| | - Di Wu
- Institute for Global Food Security, School of Biological Sciences, Queen's University Belfast, 19 Chlorine Gardens, Belfast BT9 5DL, United Kingdom
| | - Lin Li
- Animal-Derived Food Safety Innovation Team, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, China
| | - Yongning Wu
- NHC Key Laboratory of Food Safety Risk Assessment, China National Center for Food Safety Risk Assessment, Beijing 100017, China
| | - Guoliang Li
- School of Food Science and Engineering, Shaanxi University of Science and Technology, Xi'an 710021, China
| |
Collapse
|
4
|
Zhang L, Wen S, Khan JU, Liu Y, Maddahfar M, Zhou J, Jin D. Ultrasensitive Rapid Antigen Test by Geometric Lateral Flow Assays and Highly Doped Upconversion Nanoparticles. Anal Chem 2024; 96:16581-16589. [PMID: 39374910 DOI: 10.1021/acs.analchem.4c02379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/09/2024]
Abstract
The paper-based lateral flow assay (LFA) testing strips are currently the most widely used for point-of-care testing (POCT), valued for their rapid result turnaround times in a few minutes. However, their sensitivity has been limited. Upconversion nanoparticles (UCNPs), especially highly doped ones, have emerged as promising luminescent reporters to enhance the LFA sensitivity. These UCNPs exhibit a nonlinear enhancement in luminescence with excitation power density, necessitating higher power densities for higher brightness. In this study, we utilized a geometric paper strip design to minimize the immune reaction area and maximize the excitation power density, enabling ultrasensitive detection of the SARS-CoV-2 nucleoprotein antigen. This design also slowed the antigen flow on the paper strip, extending the reaction time between antigen and antibody, thereby enhancing the efficiency of the immune reaction. Through this design, our approach achieved over a 100-fold enhancement in the limit of detection (LOD) compared with the widely used LFAs, based on gold colloidal nanoparticles and europium nanoparticles. This innovation expands the scope of LFA applications that require a low LOD.
Collapse
Affiliation(s)
- Le Zhang
- Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Ultimo 2007, New South Wales, Australia
| | - Shihui Wen
- Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Ultimo 2007, New South Wales, Australia
| | - Jawairia Umar Khan
- Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Ultimo 2007, New South Wales, Australia
| | - Yuan Liu
- Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Ultimo 2007, New South Wales, Australia
| | - Mahnaz Maddahfar
- Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Ultimo 2007, New South Wales, Australia
| | - Jiajia Zhou
- Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Ultimo 2007, New South Wales, Australia
| | - Dayong Jin
- Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Ultimo 2007, New South Wales, Australia
| |
Collapse
|
5
|
Qin M, Khan IM, Ding N, Qi S, Dong X, Zhang Y, Wang Z. Aptamer-modified paper-based analytical devices for the detection of food hazards: Emerging applications and future perspective. Biotechnol Adv 2024; 73:108368. [PMID: 38692442 DOI: 10.1016/j.biotechadv.2024.108368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 03/10/2024] [Accepted: 04/24/2024] [Indexed: 05/03/2024]
Abstract
Food analysis plays a critical role in assessing human health risks and monitoring food quality and safety. Currently, there is a pressing need for a reliable, portable, and quick recognition element for point-of-care testing (POCT) to better serve the demands of on-site food analysis. Aptamer-modified paper-based analytical devices (Apt-PADs) have excellent characteristics of high portability, high sensitivity, high specificity, and on-site detection, which have been widely used and concerned in the field of food safety. The article reviews the basic components and working principles of Apt-PADs, and introduces their representative applications detecting food hazards. Finally, the advantages, challenges, and future directions of Apt-PADs-based sensing performance are discussed, to provide new directions and insights for researchers to select appropriate Apt-PADs according to specific applications.
Collapse
Affiliation(s)
- Mingwei Qin
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Imran Mahmood Khan
- Nottingham Ningbo China Beacons of Excellence Research and Innovation Institute, University of Nottingham Ningbo China, Ningbo 315100, PR China
| | - Ning Ding
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Shuo Qi
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Xiaoze Dong
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Yin Zhang
- Key Laboratory of Meat Processing of Sichuan, Chengdu University, Chengdu 610106, China
| | - Zhouping Wang
- State Key Laboratory of Food Science and Resources, Jiangnan University, Wuxi 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi 214122, China; Key Laboratory of Meat Processing of Sichuan, Chengdu University, Chengdu 610106, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China; National Engineering Research Center for Functional Food, Jiangnan University, Wuxi 214122, China.
| |
Collapse
|
6
|
Pei X, Liu J, Zhang Y, Huang Y, Li Z, Niu X, Zhang W, Sun W. Tetrahedral DNA-linked aptamer-antibody-based sandwich-type electrochemical sensor with Ag@Au core-shell nanoparticles as a signal amplifier for highly sensitive detection of α-fetoprotein. Mikrochim Acta 2024; 191:414. [PMID: 38904836 DOI: 10.1007/s00604-024-06485-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Accepted: 06/03/2024] [Indexed: 06/22/2024]
Abstract
The conventional electrochemical detection strategy for alpha-fetoprotein (AFP) is limited by the antigen-antibody (Ag-Ab) reactions and suffers from low sensitivity and poor reproducibility due to the inconsistency of Ab-modified electrodes. Herein, we designed and explored a sandwich-type electrochemical sensor for highly sensitive detection of AFP based on aptamer (Apt)-AFP-Ab interaction mode with silver@gold (Ag@Au) core-shell nanoparticles (NPs) as a signal amplifier. AuNPs were electrodeposited onto MXene (Ti3C2TX)-modified glassy carbon electrode (GCE) to get AuNPs/MXene/GCE and further used as the signal amplification substrate. The tetrahedral DNA-linked AFP aptamers were immobilized onto AuNPs/MXene/GCE surface via Au-S bonds and used as the sensing and recognition platform for AFP capturing. Ag@AuNPs with core-shell structures were synthesized, characterized, and bound with Ab as detection elements by catalyzing H2O2 reduction. In the presence of AFP, a stable Apt-AFP-Ab sandwich structure was formed owing to the high affinities of aptamer and Ab toward the target AFP. The catalytic current produced by H2O2 reduction increased linearly with the logarithm of AFP concentration from 5 × 10-4 ng/mL to 1 × 105 ng/mL, accompanied by a low detection limit (1.6 × 10-4 ng/mL). Moreover, the novel sandwich-type electrochemical sensor shows high sensitivity, outstanding selectivity, and promising performance in the analysis of actual samples, displaying a broad application prospect in bioanalysis.
Collapse
Affiliation(s)
- Xiaoying Pei
- School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo, 255049, P. R. China
| | - Junhong Liu
- School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo, 255049, P. R. China
| | - Yulong Zhang
- School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo, 255049, P. R. China
| | - Yan Huang
- School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo, 255049, P. R. China
| | - Zhongfang Li
- School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo, 255049, P. R. China
| | - Xueliang Niu
- School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo, 255049, P. R. China.
| | - Weili Zhang
- College of Pharmacy, Key Laboratory of Biomedical Engineering and Technology in Universities of Shandong, Qilu Medical University, Zibo, 255300, P. R. China.
| | - Wei Sun
- Hainan Engineering Research Center of Tropical Ocean Advanced Optoelectronic Functional Materials, Hainan International Joint Research Center of Marine Advanced Photoelectric Functional Materials, Key Laboratory of Laser Technology and Optoelectronic Functional Materials of Hainan Province, Key Laboratory of Functional Materials and Photoelectrochemistry of Haikou, College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou, 571158, P. R. China.
| |
Collapse
|
7
|
Moulahoum H, Ghorbanizamani F, Timur S. Laser-printed paper ELISA and hydroxyapatite immobilization for colorimetric congenital anomalies screening in saliva. Anal Chim Acta 2024; 1306:342617. [PMID: 38692789 DOI: 10.1016/j.aca.2024.342617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Revised: 04/07/2024] [Accepted: 04/15/2024] [Indexed: 05/03/2024]
Abstract
BACKGROUND Alpha-fetoprotein (AFP) is a fetal protein that can indicate congenital anomalies such as Down syndrome and spinal canal blockage when detected at abnormal levels in pregnant women. Current AFP detection methods rely on invasive blood or serum samples, which require sophisticated equipment. From the many solutions proposed, colorimetric paper-based assays excel in point-of-care settings. The concept of paper-based ELISA (p-ELISA) enhances traditional methods, aligning with the ASSURED criteria for diagnostics in resource-limited regions. Despite success in microfluidic paper-based assay devices, laser printing remains underexplored for p-ELISA. Additionally, modifying the paper surface provides an additional layer of sensitivity enhancement. RESULTS In this study, we developed a novel laser-printed paper-based ELISA (LP-pELISA) for rapid, sensitive, and noninvasive detection of AFP in saliva samples. The LP-pELISA platform was fabricated by printing hydrophobic barriers on filter paper using a laser printer, followed by depositing hydroxyapatite (HAp) as an immobilization material for the antibodies. The colorimetric detection was achieved using AuNPs functionalized with anti-AFP antibodies and silver nitrate enhancement. The LP-pELISA exhibited a linear response for AFP detection in both buffer and saliva samples over a range of 1.0-800 ng mL-1, with a limit of detection (LOD) reaching 1.0 ng mL-1. The assay also demonstrated good selectivity, repeatability, reproducibility, and stability. The LP-pELISA was further validated by testing spiked human saliva samples, showing its potential for point-of-care diagnosis of congenital disabilities. SIGNIFICANCE The LP-pELISA is a noninvasive platform showcasing simplicity, cost-effectiveness, and user-friendliness, utilizing laser printing, hydroxyapatite modification, and saliva samples to efficiently detect AFP. Beyond its application for AFP, this method's versatility extends to other biomarkers, positioning it as a catalyst for the evolution of paper-based biosensors. The LP-pELISA holds promise as a transformative tool for point-of-care diagnostics, fostering advancements in healthcare with its innovative technology.
Collapse
Affiliation(s)
- Hichem Moulahoum
- Biochemistry Department, Faculty of Science, Ege University, 35100, Bornova, Izmir, Turkey.
| | - Faezeh Ghorbanizamani
- Biochemistry Department, Faculty of Science, Ege University, 35100, Bornova, Izmir, Turkey
| | - Suna Timur
- Biochemistry Department, Faculty of Science, Ege University, 35100, Bornova, Izmir, Turkey; Central Research Testing and Analysis Laboratory Research and Application Center, Ege University, 35100, Bornova, Izmir, Turkey.
| |
Collapse
|
8
|
Ramachandran L, Abul Rub F, Hajja A, Alodhaibi I, Arai M, Alfuwais M, Makhzoum T, Yaqinuddin A, Al-Kattan K, Assiri AM, Broering DC, Chinnappan R, Mir TA, Mani NK. Biosensing of Alpha-Fetoprotein: A Key Direction toward the Early Detection and Management of Hepatocellular Carcinoma. BIOSENSORS 2024; 14:235. [PMID: 38785709 PMCID: PMC11117836 DOI: 10.3390/bios14050235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 04/16/2024] [Accepted: 04/25/2024] [Indexed: 05/25/2024]
Abstract
Hepatocellular carcinoma (HCC) is currently one of the most prevalent cancers worldwide. Associated risk factors include, but are not limited to, cirrhosis and underlying liver diseases, including chronic hepatitis B or C infections, excessive alcohol consumption, nonalcoholic fatty liver disease (NAFLD), and exposure to chemical carcinogens. It is crucial to detect this disease early on before it metastasizes to adjoining parts of the body, worsening the prognosis. Serum biomarkers have proven to be a more accurate diagnostic tool compared to imaging. Among various markers such as nucleic acids, circulating genetic material, proteins, enzymes, and other metabolites, alpha-fetoprotein (AFP) is a protein marker primarily used to diagnose HCC. However, current methods need a large sample and carry a high cost, among other challenges, which can be improved using biosensing technology. Early and accurate detection of AFP can prevent severe progression of the disease and ensure better management of HCC patients. This review sheds light on HCC development in the human body. Afterward, we outline various types of biosensors (optical, electrochemical, and mass-based), as well as the most relevant studies of biosensing modalities for non-invasive monitoring of AFP. The review also explains these sensing platforms, detection substrates, surface modification agents, and fluorescent probes used to develop such biosensors. Finally, the challenges and future trends in routine clinical analysis are discussed to motivate further developments.
Collapse
Affiliation(s)
- Lohit Ramachandran
- Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India;
| | - Farah Abul Rub
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (F.A.R.); (A.H.); (I.A.); (M.A.); (M.A.); (T.M.); (A.Y.); (K.A.-K.); (A.M.A.); (D.C.B.)
| | - Amro Hajja
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (F.A.R.); (A.H.); (I.A.); (M.A.); (M.A.); (T.M.); (A.Y.); (K.A.-K.); (A.M.A.); (D.C.B.)
| | - Ibrahim Alodhaibi
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (F.A.R.); (A.H.); (I.A.); (M.A.); (M.A.); (T.M.); (A.Y.); (K.A.-K.); (A.M.A.); (D.C.B.)
| | - Momo Arai
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (F.A.R.); (A.H.); (I.A.); (M.A.); (M.A.); (T.M.); (A.Y.); (K.A.-K.); (A.M.A.); (D.C.B.)
| | - Mohammed Alfuwais
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (F.A.R.); (A.H.); (I.A.); (M.A.); (M.A.); (T.M.); (A.Y.); (K.A.-K.); (A.M.A.); (D.C.B.)
| | - Tariq Makhzoum
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (F.A.R.); (A.H.); (I.A.); (M.A.); (M.A.); (T.M.); (A.Y.); (K.A.-K.); (A.M.A.); (D.C.B.)
| | - Ahmed Yaqinuddin
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (F.A.R.); (A.H.); (I.A.); (M.A.); (M.A.); (T.M.); (A.Y.); (K.A.-K.); (A.M.A.); (D.C.B.)
| | - Khaled Al-Kattan
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (F.A.R.); (A.H.); (I.A.); (M.A.); (M.A.); (T.M.); (A.Y.); (K.A.-K.); (A.M.A.); (D.C.B.)
- Lung Health Center Department, Organ Transplant Centre of Excellence, King Faisal Specialist Hospital and Research Centre, Riyadh 11211, Saudi Arabia
| | - Abdullah M. Assiri
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (F.A.R.); (A.H.); (I.A.); (M.A.); (M.A.); (T.M.); (A.Y.); (K.A.-K.); (A.M.A.); (D.C.B.)
- Tissue/Organ Bioengineering & BioMEMS Laboratory, Organ Transplant Centre of Excellence (TR&I-Dpt), King Faisal Specialist Hospital and Research Centre, Riyadh 11211, Saudi Arabia
| | - Dieter C. Broering
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (F.A.R.); (A.H.); (I.A.); (M.A.); (M.A.); (T.M.); (A.Y.); (K.A.-K.); (A.M.A.); (D.C.B.)
- Tissue/Organ Bioengineering & BioMEMS Laboratory, Organ Transplant Centre of Excellence (TR&I-Dpt), King Faisal Specialist Hospital and Research Centre, Riyadh 11211, Saudi Arabia
| | - Raja Chinnappan
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (F.A.R.); (A.H.); (I.A.); (M.A.); (M.A.); (T.M.); (A.Y.); (K.A.-K.); (A.M.A.); (D.C.B.)
- Tissue/Organ Bioengineering & BioMEMS Laboratory, Organ Transplant Centre of Excellence (TR&I-Dpt), King Faisal Specialist Hospital and Research Centre, Riyadh 11211, Saudi Arabia
| | - Tanveer Ahmad Mir
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (F.A.R.); (A.H.); (I.A.); (M.A.); (M.A.); (T.M.); (A.Y.); (K.A.-K.); (A.M.A.); (D.C.B.)
- Tissue/Organ Bioengineering & BioMEMS Laboratory, Organ Transplant Centre of Excellence (TR&I-Dpt), King Faisal Specialist Hospital and Research Centre, Riyadh 11211, Saudi Arabia
| | - Naresh Kumar Mani
- Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India;
| |
Collapse
|
9
|
Wang N, Zhang J, Xiao B, Chen A. Microfluidic-assisted integrated nucleic acid test strips for POCT. Talanta 2024; 267:125150. [PMID: 37672986 DOI: 10.1016/j.talanta.2023.125150] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 08/16/2023] [Accepted: 09/01/2023] [Indexed: 09/08/2023]
Abstract
Numerous diseases have posed significant threats to public health, notably the global pandemic of COVID-19, resulting in widespread devastation due to its high infectivity and severity. The nucleic acid lateral flow assay (NALFA) addresses challenges of complexity, cost, and time associated with traditional assays, offering a reliable platform for rapid and precise nucleic acid target detection. NALFA is gaining prominence as a point-of-care testing (POCT) technique, thanks to its user-friendly operation and rapid results. Nevertheless, conventional NALFA relies on specialized technicians and involves labor-intensive steps like DNA extraction and PCR processes, impeding its efficiency. To overcome these limitations, integrating NALFA with microfluidic technology, widely employed in rapid field detection, holds promise. This review comprehensively outlines prevailing strategies for integrating NALFA, encompassing both research initiatives and commercial applications. Addressing the bottleneck of nucleic acid amplification as a rate-limiting step, the review delves into progress in amplification-free NALFA and highlights prevalent signal amplification techniques. Ultimately, the review outlines the future prospect of integrated NALFA development, capturing the technology's evolution and providing valuable insights for academic and commercial endeavors.
Collapse
Affiliation(s)
- Nan Wang
- Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Juan Zhang
- Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Bin Xiao
- Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Ailiang Chen
- Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing, 100081, China.
| |
Collapse
|
10
|
Jamil SR, Abbasi MS, Jafry AT, Shahzad T, Sarwar S, Qureshi MH. Flow control by circular cavities in lateral flow porous membranes. Sci Prog 2024; 107:368504241235508. [PMID: 38426804 PMCID: PMC10908241 DOI: 10.1177/00368504241235508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
This research explores the flow penetration in porous media by virtue of capillary action and geometric control of the liquid imbibition rate in microfluidic paper-based analytical devices (μPADs) having applications in food quality management, medical diagnostics, and environmental monitoring. We examine changes in flow resistance and membrane geometry, aiming to understand factors influencing capillary penetration rates for various practical applications. We conducted experiments and simulations using lateral porous membranes and altered the flow resistance by changing the liquids or the paper channel geometry by adding cavities. From experiments, it was revealed that by creating a circular cavity in the paper channel, the penetration rate was sufficiently altered. Moreover, increasing the cavity size and type of liquid (w.r.t. viscosity) also caused a decrease in the flow rate. Imbibition rates were also influenced by the position of the cavities in the paper channel. The maximum delay for water was almost 2 times with a 16 mm circular cavity located at 3 cm from strip bottom edge. Overall, we attained a maximum delay in the case of castor oil which was almost 85 times slower than water and 3.7 times slower than olive oil. A good agreement was observed with CFD analysis. We believe that this research would help in developing advance techniques to enhance the flow control strategies in μPADs and indicators.
Collapse
Affiliation(s)
- Syed Rehman Jamil
- Faculty of Mechanical Engineering, University of Engineering and Technology, Lahore, Pakistan
| | - Muhammad Salman Abbasi
- Faculty of Mechanical Engineering, University of Engineering and Technology, Lahore, Pakistan
| | - Ali Turab Jafry
- Faculty of Mechanical Engineering, Ghulam Ishaq Khan Institute of Engineering Sciences and Technology, Topi, Pakistan
| | - Tanveer Shahzad
- Faculty of Mechanical Engineering, University of Engineering and Technology, Lahore, Pakistan
| | - Shahid Sarwar
- Faculty of Mechanical Engineering, University of Engineering and Technology, Lahore, Pakistan
| | - Muhammad Hammad Qureshi
- Faculty of Mechanical Engineering, University of Engineering and Technology, Lahore, Pakistan
| |
Collapse
|
11
|
Chai F, Wang D, Shi F, Zheng W, Zhao X, Chen Y, Mao C, Zhang J, Jiang X. Dual Functional Ultrasensitive Point-of-Care Clinical Diagnosis Using Metal-Organic Frameworks-Based Immunobeads. NANO LETTERS 2023; 23:9056-9064. [PMID: 37738391 DOI: 10.1021/acs.nanolett.3c02828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/24/2023]
Abstract
Sepsis is an acute systemic infectious syndrome with high fatality. Fast and accurate diagnosis, monitoring, and medication of sepsis are essential. We exploited the fluorescent metal-AIEgen frameworks (MAFs) and demonstrated the dual functions of protein detection and bacteria identification: (i) ultrasensitive point-of-care (POC) detection of sepsis biomarkers (100 times enhanced sensitivity); (ii) rapid POC identification of Gram-negative/positive bacteria (selective aggregation within 20 min). Fluorescent lateral flow immunoassays (LFAs) are convenient and inexpensive for POC tests. MAFs possess a large surface area, excellent photostability, high quantum yield (∼80%), and multiple active sites serving as protein binding domains for ultrasensitive detection of sepsis biomarkers (IL-6/PCT) on LFAs. The limit of detection (LOD) for IL-6/PCT is 0.252/0.333 pg/mL. Rapid appraisal of infectious bacteria is vital to guide the use of medicines. The dual-functional fluorescent MAFs have great potential in POC tests for the clinical diagnosis of bacterial infections.
Collapse
Affiliation(s)
- Fengli Chai
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Dou Wang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Fei Shi
- Shenzhen People's Hospital (The First Affiliated Hospital of Southern University of Science and Technology, The Second Clinical Medical College of Jinan University), Shenzhen, Guangdong 518020, China
| | - Wenfu Zheng
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Laboratory for Biological Effects of Nanomaterials and Nanosafety, National Center for NanoScience and Technology, Beijing 100190, China
| | - Xiaohui Zhao
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Yao Chen
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Cuiping Mao
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Jiangjiang Zhang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
- Key Laboratory of Molecular Medicine and Biotherapy, the Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, Beijing 100081, China
| | - Xingyu Jiang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| |
Collapse
|
12
|
Brito-Pereira R, Silva Macedo A, Ribeiro C, Cardoso VF, Lanceros-Méndez S. Natural Indigenous Paper Substrates for Colorimetric Bioassays in Portable Analytical Systems: Sustainable Solutions from the Rain Forests to the Great Plains. ACS APPLIED MATERIALS & INTERFACES 2023; 15:46747-46755. [PMID: 37782693 DOI: 10.1021/acsami.3c11928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
Point-of-care (POC) devices can provide inexpensive, practical, and expedited solutions for applications ranging from biomedicine to environmental monitoring. This work reports on the development of low-cost microfluidic substrates for POC systems suitable for analytical assays, while also satisfying the need for social and environmentally conscious practices regarding circular economy, waste reduction, and the use of local resources. Thus, an innovative greener process to extract cellulose from plants including abaca, cotton, kozo, linen, and sisal, originating from different places around the world, is developed, and then the corresponding paper substrates are obtained to serve as platforms for POC assays. Hydrophobic wax is used to delineate channels that are able to guide solutions into chambers where the colorimetric assay for total cholesterol quantification is carried out as a proof of concept. Morphological and physicochemical analyses are performed, including the evaluation of fiber diameter, shape and density, and mechanical and thermal properties, together with peel adhesion of the printed wax channels. Contact angle and capillary flow tests ascertain the suitability of the substrates for liquid assays and overall viability as low-cost, sustainable microfluidic substrates for POC applications.
Collapse
Affiliation(s)
- Ricardo Brito-Pereira
- CMEMS-UMinho, Universidade do Minho, Campus de Azurém, 4800-058 Guimarães, Portugal
- LABBELS-Associate Laboratory, 4710-057 Braga, Portugal
- CF-UM-UP, Centro de Física das Universidades do Minho e Porto, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LaPMET─Laboratory of Physics for Materials and Emergent Technologies, Universidade do Minho, 4710-057 Braga, Portugal
- IB-S, Institute of Science and Innovation for Bio-Sustainability, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
| | - André Silva Macedo
- CF-UM-UP, Centro de Física das Universidades do Minho e Porto, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LaPMET─Laboratory of Physics for Materials and Emergent Technologies, Universidade do Minho, 4710-057 Braga, Portugal
- IB-S, Institute of Science and Innovation for Bio-Sustainability, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
| | - Clarisse Ribeiro
- CF-UM-UP, Centro de Física das Universidades do Minho e Porto, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LaPMET─Laboratory of Physics for Materials and Emergent Technologies, Universidade do Minho, 4710-057 Braga, Portugal
| | - Vanessa F Cardoso
- CMEMS-UMinho, Universidade do Minho, Campus de Azurém, 4800-058 Guimarães, Portugal
- LABBELS-Associate Laboratory, 4710-057 Braga, Portugal
| | - Senentxu Lanceros-Méndez
- CF-UM-UP, Centro de Física das Universidades do Minho e Porto, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal
- LaPMET─Laboratory of Physics for Materials and Emergent Technologies, Universidade do Minho, 4710-057 Braga, Portugal
- BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain
- IKERBASQUE, Basque Foundation for Science, 48009 Bilbao, Spain
| |
Collapse
|
13
|
Olorundare FOG, Sipuka DS, Sebokolodi TI, Kodama T, Arotiba OA, Nkosi D. An electrochemical immunosensor for an alpha-fetoprotein cancer biomarker on a carbon black/palladium hybrid nanoparticles platform. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:3577-3585. [PMID: 37458385 DOI: 10.1039/d3ay00702b] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/28/2023]
Abstract
The early detection of cancer is a key step in cancer survival. Thus, there is a need to develop low-cost technologies, such as electrochemical immunosensor technologies, for timely screening and diagnostics. The discovery of alpha-feto protein (AFP) as a tumour-associated antigen lends AFP as a biomarker for cancer detection and monitoring. Thus, immunosensors can be developed to target AFP in cancer diagnostics. Hence, we report the application of a hybrid nanocomposite of carbon black nanoparticles (CBNPs) and palladium nanoparticles (PdNPs) as a platform for the electrochemical immunosensing of cancer biomarkers. The hybrid carbon-metal nanomaterials were immobilised by using the drop-drying and electrodeposition technique on a glassy carbon electrode, followed by the immobilisation of the anti-AFP to fabricate an immunosensor. The nanoparticles were characterised with electron microscopy, voltammetry, and electrochemical impedance spectroscopy (EIS). Square wave voltammetry (SWV) and EIS were used to study the immunosensor signal toward the bio-recognition of the AFP cancer biomarker. The hybrid nanoparticles enhanced the immunosensor performance. A linear detection range from 0.005 to 1000 ng mL-1 with low detection limits of 0.0039 ng mL-1 and 0.0131 ng mL-1 were calculated for SWV and EIS, respectively. The immunosensor demonstrated good stability, reproducibility, and selectivity. Its real-life application potential was tested with detection in human serum matrix.
Collapse
Affiliation(s)
- Foluke O G Olorundare
- Department of Chemical Sciences, University of Johannesburg, Doornfontein 2028, Johannesburg, South Africa.
| | - Dimpo S Sipuka
- Department of Chemical Sciences, University of Johannesburg, Doornfontein 2028, Johannesburg, South Africa.
- Centre for Nanomaterials Science Research, University of Johannesburg, South Africa
| | - Tsholofelo I Sebokolodi
- Department of Chemical Sciences, University of Johannesburg, Doornfontein 2028, Johannesburg, South Africa.
- Centre for Nanomaterials Science Research, University of Johannesburg, South Africa
| | - Tetsuya Kodama
- Laboratory of Biomedical Engineering for Cancer, Graduate School of Biomedical Engineering, Tohoku University, 4-1 Seiryo, Aoba, Sendai, Miyagi, 980-8575, Japan
| | - Omotayo A Arotiba
- Department of Chemical Sciences, University of Johannesburg, Doornfontein 2028, Johannesburg, South Africa.
- Centre for Nanomaterials Science Research, University of Johannesburg, South Africa
| | - Duduzile Nkosi
- Department of Chemical Sciences, University of Johannesburg, Doornfontein 2028, Johannesburg, South Africa.
- Centre for Nanomaterials Science Research, University of Johannesburg, South Africa
| |
Collapse
|
14
|
Benjamin SR, de Lima F, Nascimento VAD, de Andrade GM, Oriá RB. Advancement in Paper-Based Electrochemical Biosensing and Emerging Diagnostic Methods. BIOSENSORS 2023; 13:689. [PMID: 37504088 PMCID: PMC10377443 DOI: 10.3390/bios13070689] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 06/09/2023] [Accepted: 06/19/2023] [Indexed: 07/29/2023]
Abstract
The utilization of electrochemical detection techniques in paper-based analytical devices (PADs) has revolutionized point-of-care (POC) testing, enabling the precise and discerning measurement of a diverse array of (bio)chemical analytes. The application of electrochemical sensing and paper as a suitable substrate for point-of-care testing platforms has led to the emergence of electrochemical paper-based analytical devices (ePADs). The inherent advantages of these modified paper-based analytical devices have gained significant recognition in the POC field. In response, electrochemical biosensors assembled from paper-based materials have shown great promise for enhancing sensitivity and improving their range of use. In addition, paper-based platforms have numerous advantageous characteristics, including the self-sufficient conveyance of liquids, reduced resistance, minimal fabrication cost, and environmental friendliness. This study seeks to provide a concise summary of the present state and uses of ePADs with insightful commentary on their practicality in the field. Future developments in ePADs biosensors include developing novel paper-based systems, improving system performance with a novel biocatalyst, and combining the biosensor system with other cutting-edge tools such as machine learning and 3D printing.
Collapse
Affiliation(s)
- Stephen Rathinaraj Benjamin
- Drug Research and Development Center (NPDM), Federal University of Cearà, Fortaleza 60430-270, CE, Brazil
- Department of Physiology and Pharmacology, Faculty of Medicine, Federal University of Cearà, Fortaleza 60430-270, CE, Brazil
| | - Fábio de Lima
- Post Graduate Program in Health and Development in the Central-West Region of Brazil, Federal University of Mato Grosso do Sul UFMS, Campo Grande 79070-900, MS, Brazil
| | - Valter Aragão do Nascimento
- Post Graduate Program in Health and Development in the Central-West Region of Brazil, Federal University of Mato Grosso do Sul UFMS, Campo Grande 79070-900, MS, Brazil
| | - Geanne Matos de Andrade
- Drug Research and Development Center (NPDM), Federal University of Cearà, Fortaleza 60430-270, CE, Brazil
- Department of Physiology and Pharmacology, Faculty of Medicine, Federal University of Cearà, Fortaleza 60430-270, CE, Brazil
| | - Reinaldo Barreto Oriá
- Laboratory of the Biology of Tissue Healing, Ontogeny and Nutrition, Department of Morphology, Institute of Biomedicine, School of Medicine, Federal University of Cearà, Fortaleza 60430-270, CE, Brazil
| |
Collapse
|
15
|
Carrell C, Jang I, Link J, Terry JS, Call Z, Panraksa Y, Chailapakul O, Dandy DS, Geiss BJ, Henry CS. Capillary driven microfluidic sequential flow device for point-of-need ELISA: COVID-19 serology testing. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:2721-2728. [PMID: 37099406 PMCID: PMC10249653 DOI: 10.1039/d3ay00225j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Accepted: 04/16/2023] [Indexed: 06/09/2023]
Abstract
A capillary-driven microfluidic sequential flow device, designed for eventual at-home or doctor's office use, was developed to perform an enzyme-linked immunosorbent assay (ELISA) for serology assays. Serology assays that detect SARS-CoV-2 antibodies can be used to determine prior infection, immunity status, and/or individual vaccination status and are typically run using well-plate ELISAs in centralized laboratories, but in this format SARs-CoV-2 serology tests are too expensive and/or slow for most situations. Instead, a point-of-need device that can be used at home or in doctor's offices for COVID-19 serology testing would provide critical information for managing infections and determining immune status. Lateral flow assays are common and easy to use, but lack the sensitivity needed to reliably detect SARS-CoV-2 antibodies in clinical samples. This work describes a microfluidic sequential flow device that is as simple to use as a lateral flow assay, but as sensitive as a well-plate ELISA through sequential delivery of reagents to the detection area using only capillary flow. The device utilizes a network of microfluidic channels made of transparency film and double-sided adhesive combined with paper pumps to drive flow. The geometry of the channels and storage pads enables automated sequential washing and reagent addition steps with two simple end-user steps. An enzyme label and colorimetric substrate produce an amplified, visible signal for increased sensitivity, while the integrated washing steps decrease false positives and increase reproducibility. Naked-eye detection can be used for qualitative results or a smartphone camera for quantitative analysis. The device detected antibodies at 2.8 ng mL-1 from whole blood, while a well-plate ELISA using the same capture and detection antibodies could detect 1.2 ng mL-1. The performance of the capillary-driven immunoassay (CaDI) system developed here was confirmed by demonstrating SARS-CoV-2 antibody detection, and we believe that the device represents a fundamental step forward in equipment-free point-of-care technology.
Collapse
Affiliation(s)
- Cody Carrell
- Department of Chemistry, Colorado State University, CO, 80523, USA.
| | - Ilhoon Jang
- Department of Chemistry, Colorado State University, CO, 80523, USA.
- Department of Mechanical Engineering, Hanyang University, Seoul, 04763, Korea
| | - Jeremy Link
- Department of Chemistry, Colorado State University, CO, 80523, USA.
| | - James S Terry
- Department of Microbiology, Immunology and Pathology, Colorado State University, CO, 80523, USA
| | - Zachary Call
- Department of Chemistry, Colorado State University, CO, 80523, USA.
| | - Yosita Panraksa
- Program in Biotechnology, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Orawon Chailapakul
- Program in Biotechnology, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - David S Dandy
- Department of Chemical and Biological Engineering, Colorado State University, CO, 80523, USA
- School of Biomedical Engineering, Colorado State University, CO, 80523, USA
| | - Brian J Geiss
- Department of Microbiology, Immunology and Pathology, Colorado State University, CO, 80523, USA
- School of Biomedical Engineering, Colorado State University, CO, 80523, USA
| | - Charles S Henry
- Department of Chemistry, Colorado State University, CO, 80523, USA.
- Department of Chemical and Biological Engineering, Colorado State University, CO, 80523, USA
- School of Biomedical Engineering, Colorado State University, CO, 80523, USA
| |
Collapse
|
16
|
Zhang T, Yang L, Yan F, Wang K. Vertically-Ordered Mesoporous Silica Film Based Electrochemical Aptasensor for Highly Sensitive Detection of Alpha-Fetoprotein in Human Serum. BIOSENSORS 2023; 13:628. [PMID: 37366993 DOI: 10.3390/bios13060628] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 05/24/2023] [Accepted: 05/26/2023] [Indexed: 06/28/2023]
Abstract
Convenient and rapid detection of alpha fetoprotein (AFP) is vital for early diagnosis of hepatocellular carcinoma. In this work, low-cost (0.22 USD for single sensor) and stable (during 6 days) electrochemical aptasensor was developed for highly sensitive and direct detection of AFP in human serum with the assist of vertically-ordered mesoporous silica films (VMSF). VMSF has silanol groups on the surface and regularly ordered nanopores, which could provide binding sites for further functionalization of recognition aptamer and also confer the sensor with excellent anti-biofouling capacity. The sensing mechanism relies on the target AFP-controlled diffusion of Fe(CN)63-/4- redox electrochemical probe through the nanochannels of VMSF. The resulting reduced electrochemical responses are related to the AFP concentration, allowing the linear determination of AFP with a wide dynamic linear range and a low limit of detection. Accuracy and potential of the developed aptasensor were also demonstrated in human serum by standard addition method.
Collapse
Affiliation(s)
- Tongtong Zhang
- Key Laboratory of Integrated Oncology and Intelligent Medicine of Zhejiang Province, Department of Hepatobiliary and Pancreatic Surgery, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou 310006, China
| | - Luoxiang Yang
- Key Laboratory of Surface & Interface Science of Polymer Materials of Zhejiang Province, Department of Chemistry, Zhejiang Sci-Tech University, Hangzhou 310018, China
| | - Fei Yan
- Key Laboratory of Surface & Interface Science of Polymer Materials of Zhejiang Province, Department of Chemistry, Zhejiang Sci-Tech University, Hangzhou 310018, China
| | - Kai Wang
- Key Laboratory of Integrated Oncology and Intelligent Medicine of Zhejiang Province, Department of Hepatobiliary and Pancreatic Surgery, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou 310006, China
| |
Collapse
|
17
|
Yaiwong P, Anuthum S, Sangthong P, Jakmunee J, Bamrungsap S, Ounnunkad K. A new portable toluidine blue/aptamer complex-on-polyethyleneimine-coated gold nanoparticles-based sensor for label-free electrochemical detection of alpha-fetoprotein. Front Bioeng Biotechnol 2023; 11:1182880. [PMID: 37284243 PMCID: PMC10239980 DOI: 10.3389/fbioe.2023.1182880] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Accepted: 04/28/2023] [Indexed: 06/08/2023] Open
Abstract
The quantification of alpha-fetoprotein (AFP) as a potential liver cancer biomarker which is generally found in ultratrace level is of significance in biomedical diagnostics. Therefore, it is challenging to find a strategy to fabricate a highly sensitive electrochemical device towards AFP detection through electrode modification for signal generation and amplification. This work shows the construction of a simple, reliable, highly sensitive, and label-free aptasensor based on polyethyleneimine-coated gold nanoparticles (PEI-AuNPs). A disposable ItalSens screen-printed electrode (SPE) is employed for fabricating the sensor by successive modifying with PEI-AuNPs, aptamer, bovine serum albumin (BSA), and toluidine blue (TB), respectively. The AFP assay is easily performed when the electrode is inserted into a small Sensit/Smart potentiostat connected to a smartphone. The readout signal of the aptasensor derives from the electrochemical response of TB intercalating into the aptamer-modified electrode after binding with the target. The decrease in current response of the proposed sensor is proportional to the AFP concentration due to the restriction of the electron transfer pathway of TB by a number of insulating AFP/aptamer complexes on the electrode surface. PEI-AuNPs improve SPE's reactivity and provide a large surface area for aptamer immobilization whereas aptamer provides selectivity to the target AFP. Consequently, this electrochemical biosensor is highly sensitive and selective for AFP analysis. The developed assay reveals a linear range of detection from 10 to 50000 pg mL-1 with R 2 = 0.9977 and provided a limit of detection (LOD) of 9.5 pg mL-1 in human serum. With its simplicity and robustness, it is anticipated that this electrochemical-based aptasensor will be a benefit for the clinical diagnosis of liver cancer and further developed for other biomarkers analysis.
Collapse
Affiliation(s)
- Patrawadee Yaiwong
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- The Graduate School, Chiang Mai University, Chiang Mai, Thailand
| | - Siriporn Anuthum
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- The Graduate School, Chiang Mai University, Chiang Mai, Thailand
| | - Padchanee Sangthong
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
| | - Jaroon Jakmunee
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
| | - Suwussa Bamrungsap
- National Nanotechnology Center (NANOTEC), National Science and Technology Development Agency (NSTDA), Pathum Thani, Thailand
| | - Kontad Ounnunkad
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
| |
Collapse
|
18
|
Chen Y, Xu A, Li J, Zhu X, Zou M, Liu S. Highly sensitive paper-based immunoassay: Combining nanomaterials modified cellulose with covalent and oriented immobilization of antibody. J Pharm Biomed Anal 2023; 231:115389. [PMID: 37087775 DOI: 10.1016/j.jpba.2023.115389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 03/31/2023] [Accepted: 04/07/2023] [Indexed: 04/25/2023]
Abstract
Among the analytical tools, paper-based analytical devices (PADs) have become a leading alternative for point-of care testing (POCT). In this study, PADs were fabricated using an office laser printer. Then, the paper zone was modified with graphene oxide (GO) and pyrene derivatives, which provide a sufficient amount of carboxylic groups for conjugating antibodies. At an optimal pH, antibodies were covalently bound onto carboxylated cellulose surface in an oriented manner through a two-step strategy: electrostatic adsorption was followed by EDC/NHS coupling. α-fetoprotein (AFP) as a detection model, we compared with cellulose powder modified and unmodified paper zone. The results showed the color intensity and color uniformity on GO modified paper was improved. The activity of immobilized antibodies on GO/1-pyrenebutyric acid (GO/PBA) modified was three times higher than that of GO modified and about 1.8-fold higher than that of GO/1-pyrenecarboxylic acid (GO/PCA) modified. The GO/PBA modified paper-based immunoassay has enhanced sensitivity and low detection limit. A linear correlation between color intensity and concentration of AFP in the range of 0.01~16.5 ng mL-1 with a detection limit of 9.0 pg mL-1 were achieved, respectively. The obtained results point towards rapid, sensitive, and specific early diagnosis of liver cancer at the point of care and other low-resource settings.
Collapse
Affiliation(s)
- Yafang Chen
- School of Public Health, Nantong University, Nantong 226019, China
| | - Anan Xu
- School of Public Health, Nantong University, Nantong 226019, China
| | - Jiajia Li
- School of Life Sciences, Nantong University, Nantong 226019, China
| | - Xiaoxia Zhu
- School of Public Health, Nantong University, Nantong 226019, China.
| | - Meiyin Zou
- The Third People's Hospital of Nantong, Nantong 226007, China.
| | - Shan Liu
- The Ninth People's Hospital of Suzhou, Suzhou 215200, China
| |
Collapse
|
19
|
Lu S, Lin Y, Lin Z, Shi B. Sensitive and Label‐Free Electrochemical Immunosensor for Alpha Fetoprotein Based on N‐Doped Hollow Nanocarbon Spheres Decorated with Gold Nanoparticles. ChemistrySelect 2023. [DOI: 10.1002/slct.202204101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023]
Affiliation(s)
- Shiyun Lu
- Provincial Clinical College of Fujian Medical University, Fujian Provincial Hospital Fuzhou Fujian PR China
| | - Yun Lin
- Provincial Clinical College of Fujian Medical University Fujian Provincial Hospital South Branch Fuzhou Fujian PR China
| | - Zhihui Lin
- Provincial Clinical College of Fujian Medical University, Fujian Provincial Hospital Fuzhou Fujian PR China
| | - Bing Shi
- Provincial Clinical College of Fujian Medical University Fujian Provincial Hospital South Branch Fuzhou Fujian PR China
| |
Collapse
|
20
|
Kim ER, Joe C, Mitchell RJ, Gu MB. Biosensors for healthcare: current and future perspectives. Trends Biotechnol 2023; 41:374-395. [PMID: 36567185 DOI: 10.1016/j.tibtech.2022.12.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 11/28/2022] [Accepted: 12/06/2022] [Indexed: 12/24/2022]
Abstract
Biosensors are utilized in several different fields, including medicine, food, and the environment; in this review, we examine recent developments in biosensors for healthcare. These involve three distinct types of biosensor: biosensors for in vitro diagnosis with blood, saliva, or urine samples; continuous monitoring biosensors (CMBs); and wearable biosensors. Biosensors for in vitro diagnosis have seen a significant expansion recently, with newly reported clustered regularly interspaced short palindromic repeats (CRISPR)/Cas methodologies and improvements to many established integrated biosensor devices, including lateral flow assays (LFAs) and microfluidic/electrochemical paper-based analytical devices (μPADs/ePADs). We conclude with a discussion of two novel groups of biosensors that have drawn great attention recently, continuous monitoring and wearable biosensors, as well as with perspectives on the commercialization and future of biosensors.
Collapse
Affiliation(s)
- Eun Ryung Kim
- Department of Biotechnology, Korea University, Anam-dong, Sungbuk-Gu, Seoul 02841, Republic of Korea
| | - Cheulmin Joe
- Department of Biotechnology, Korea University, Anam-dong, Sungbuk-Gu, Seoul 02841, Republic of Korea
| | - Robert J Mitchell
- Department of Biological Sciences, UNIST, Ulsan 44919, Republic of Korea
| | - Man Bock Gu
- Department of Biotechnology, Korea University, Anam-dong, Sungbuk-Gu, Seoul 02841, Republic of Korea.
| |
Collapse
|
21
|
Karim K, Lamaoui A, Amine A. Paper-based optical sensors paired with smartphones for biomedical analysis. J Pharm Biomed Anal 2023; 225:115207. [PMID: 36584551 DOI: 10.1016/j.jpba.2022.115207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 12/07/2022] [Accepted: 12/16/2022] [Indexed: 12/24/2022]
Abstract
The traditional analytical methods used for biomedical analysis are expensive and not easy to handle and require sophisticated instruments, thus their application is limited in resource-limited settings. Due to their portability, low cost, and ability to be applied to different analytical techniques, paper-based analytical devices are becoming valuable tools for biomedical analysis. The integration of smartphones into analytical devices has provided the ability to build portable, cost-effective, straightforward analytical devices for biomedical analysis and mobile health. The key aim of this review is to emphasize the recent applications of PADs combined with a smartphone for the optical analysis of biomedical species. We started this review by highlighting the type of papers and their modifications with different materials to prepare the PADs. After that, this review presents various detection methods including colorimetry, fluorescence, and luminescence where the smartphone is used for read-out. In the end, we provided the recent applications of the analysis of different biomedical compounds such as cancer and cardiovascular biomarkers, metal ions, glucose, viruses, etc. We believe that the present review will attract a wide scientific community in the areas of analytical chemistry, sensors, and clinical testing.
Collapse
Affiliation(s)
- Khadija Karim
- Laboratoire Génie des Procedés & Environnement, Faculté des Sciences et Techniques, Hassan II University of Casablanca, B.P. 146, Mohammedia, Morocco
| | - Abderrahman Lamaoui
- Laboratoire Génie des Procedés & Environnement, Faculté des Sciences et Techniques, Hassan II University of Casablanca, B.P. 146, Mohammedia, Morocco
| | - Aziz Amine
- Laboratoire Génie des Procedés & Environnement, Faculté des Sciences et Techniques, Hassan II University of Casablanca, B.P. 146, Mohammedia, Morocco.
| |
Collapse
|
22
|
Wang X, Zheng X, Song Z, Lin D, Li Q, Qi J, Xiang J, Chen L, Li B. Electric yo-yo centrifugation combining with paper-based microfluidic immunoassay chip for inflammatory biomarkers detection in whole blood. Talanta 2023; 253:123883. [PMID: 36137494 DOI: 10.1016/j.talanta.2022.123883] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 06/25/2022] [Accepted: 08/23/2022] [Indexed: 12/13/2022]
Abstract
At present, most countries or regions use commercial centrifuges for centrifugation, but this is out of reaching for limited-resource areas. To overcome this problem, a portable electric yo-yo as centrifuge was firstly proposed to obtain serum, and this device can be combined with paper-based analytical devices for enzyme-linked immunosorbent assay (ELISA) analysis from human whole blood. In this study, inflammatory biomarkers C-reactive protein (CRP) and serum amyloid A (SAA) were used as target biomarker to verify the performance of the proposed method. The results shows good performance and their detection limits were determined to be 580 pg/mL for CRP and 800 pg/mL for SAA, respectively. We believe this method provides a new platform of low cost and fast detection for inflammatory biomarkers in the limited-resource settings.
Collapse
Affiliation(s)
- Xiaolei Wang
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Institute of Molecular and Nano Science, Shandong Normal University, Jinan, 250014, PR China
| | - Xiaoli Zheng
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Institute of Molecular and Nano Science, Shandong Normal University, Jinan, 250014, PR China
| | - Zhihua Song
- School of Pharmacy, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Key Laboratory of Molecular Pharmacology and Drug Evaluation, Ministry of Education, Yantai University, Yantai, 264005, PR China
| | - Dong Lin
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, PR China
| | - Qingling Li
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Institute of Molecular and Nano Science, Shandong Normal University, Jinan, 250014, PR China
| | - Ji Qi
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, PR China
| | - Jiawen Xiang
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, PR China
| | - Lingxin Chen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, PR China.
| | - Bowei Li
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Research Center for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, PR China.
| |
Collapse
|
23
|
Li X, Huang J, Ding J, Xiu M, Huang K, Cui K, Zhang J, Hao S, Zhang Y, Yu J, Huang Y. PEC/Colorimetric Dual-Mode Lab-on-Paper Device via BiVO 4/FeOOH Nanocomposite In Situ Modification on Paper Fibers for Sensitive CEA Detection. BIOSENSORS 2023; 13:103. [PMID: 36671939 PMCID: PMC9855910 DOI: 10.3390/bios13010103] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 01/02/2023] [Accepted: 01/04/2023] [Indexed: 06/06/2023]
Abstract
A dual-mode lab-on-paper device based on BiVO4/FeOOH nanocomposites as an efficient generating photoelectrochemical (PEC)/colorimetric signal reporter has been successfully constructed by integration of the lab-on-paper sensing platform and PEC/colorimetric detection technologies for sensitive detection of carcinoembryonic antigen (CEA). Concretely, the BiVO4/FeOOH nanocomposites were in situ synthesized onto the paper-working electrode (PWE) through hydrothermal synthesis of the BiVO4 layer on cellulose fibers (paper-based BiVO4) which were initially modified by Au nanoparticles for improving the conductivity of three dimensional PWE, and then the photo-electrodeposition of FeOOH onto the paper-based BiVO4 to construct the paper-based BiVO4/FeOOH for the portable dual-mode lab-on-paper device. The obtained nanocomposites with an FeOOH needle-like structure deposited on the BiVO4 layer exhibits enhanced PEC response activity due to its effective separation of the electron-hole pair which could further accelerate the PEC conversion efficiency during the sensing process. With the introduction of CEA targets onto the surface of nanocomposite-modified PWE assisted by the interaction with the CEA antibody from a specific recognition property, a signal-off PEC signal state with a remarkable photocurrent response decreasing trend can be achieved, realizing the quantitative detection of CEA with the PEC signal readout mode. By means of a smart origami paper folding, the colorimetric signal readout is achieved by catalyzing 3,3',5,5'-tetramethylbenzidine (TMB) to generate blue oxidized TMB in the presence of H2O2 due to the satisfied enzyme-like catalytic activity of the needle-like structure, FeOOH, thereby achieving the dual-mode signal readout system for the proposed lab-on-paper device. Under the optimal conditions, the PEC and colorimetric signals measurement were effectively carried out, and the corresponding linear ranges were 0.001-200 ng·mL-1 and 0.5-100 ng·mL-1 separately, with the limit of detection of 0.0008 and 0.013 ng·mL-1 for each dual-mode. The prepared lab-on-paper device also presented a successful application in serum samples for the detection of CEA, providing a potential pathway for the sensitive detection of target biomarkers in clinical application.
Collapse
Affiliation(s)
- Xu Li
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Jiali Huang
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Jiayu Ding
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Mingzhen Xiu
- School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Kang Huang
- School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Kang Cui
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
- School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Jing Zhang
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Shiji Hao
- School of Materials Science & Engineering, Dongguan University of Technology, Dongguan 523808, China
| | - Yan Zhang
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, Qingdao University of Science and Technology, Qingdao 266042, China
| | - Jinghua Yu
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Yizhong Huang
- School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798, Singapore
| |
Collapse
|
24
|
Cai Q, Shi H, Sun M, Ma N, Wang R, Yang W, Qiao Z. Sensitive Detection of Salmonella Based on CRISPR-Cas12a and the Tetrahedral DNA Nanostructure-Mediated Hyperbranched Hybridization Chain Reaction. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2022; 70:16382-16389. [PMID: 36512680 DOI: 10.1021/acs.jafc.2c05831] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Salmonella severely threatens global human health and causes financial burden. The ability to sensitively detect Salmonella in food samples is highly valuable but remains a challenge. Herein, a sensitive detection method for Salmonella was developed by coupling immunomagnetic separation with the CRISPR-Cas12a system and the tetrahedral DNA nanostructure-mediated hyperbranched hybridization chain reaction (TDN-hHCR). In the detection system, the target Salmonella was immunomagnetically separated and labeled with bio-barcode DNA-modified gold nanoparticles (AuNPs), which could transfer and magnify the signal of a bacterial cell into numerous bio-barcode DNA molecules. Afterward, the bio-barcode DNA can trigger the trans-cleavage activity of CRISPR-Cas12a to inhibit the process of the TDN-hHCR to generate a fluorescence readout. Due to the high immunomagnetic separation efficiency and the effective signal amplification of CRISPR-Cas12a and the TDN-hHCR, Salmonella as low as 8 CFU/mL could be easily detected. Meanwhile, this has been applied for practical use and showed the capability to detect 17 and 25 CFU/mL in spiked milk and egg white, respectively, indicating its potential application in real samples.
Collapse
Affiliation(s)
- Qiqi Cai
- College of Food and Pharmaceutical Sciences, Ningbo University, Ningbo 315800, China
| | - Hanxing Shi
- College of Food and Pharmaceutical Sciences, Ningbo University, Ningbo 315800, China
| | - Mengni Sun
- College of Food and Pharmaceutical Sciences, Ningbo University, Ningbo 315800, China
| | - Na Ma
- College of Food and Pharmaceutical Sciences, Ningbo University, Ningbo 315800, China
| | - Rui Wang
- Human Phenome Institute, State Key Laboratory of Genetic Engineering, Fudan University, Shanghai 200438, China
| | - Wenge Yang
- College of Food and Pharmaceutical Sciences, Ningbo University, Ningbo 315800, China
| | - Zhaohui Qiao
- College of Food and Pharmaceutical Sciences, Ningbo University, Ningbo 315800, China
| |
Collapse
|
25
|
Zhang J, Li Y, Chai F, Li Q, Wang D, Liu L, Tang BZ, Jiang X. Ultrasensitive point-of-care biochemical sensor based on metal-AIEgen frameworks. SCIENCE ADVANCES 2022; 8:eabo1874. [PMID: 35895821 PMCID: PMC9328688 DOI: 10.1126/sciadv.abo1874] [Citation(s) in RCA: 33] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Point-of-care (POC) biochemical sensors have found broad applications in areas ranging from clinical diagnosis to environmental monitoring. However, POC sensors often suffer from poor sensitivity. Here, we synthesized a metal-organic framework, where the ligand is the aggregation-induced emission luminogen (AIEgen), which we call metal-AIEgen frameworks (MAFs), for use in the ultrasensitive POC biochemical sensors. MAFs process a unique luminescent mechanism of structural rigidity-enhanced emission to achieve a high quantum yield (~99.9%). We optimized the MAFs to show 102- to 103-fold enhanced sensitivity for a hydrogel-based POC digital sensor and lateral flow immunoassays (LFIA). MAFs have a high affinity to directly absorb proteins, which can label antibodies for immunoassays. MAFs-based LFIA with enhanced sensitivity shows robust serum detection for POC clinical diagnosis.
Collapse
Affiliation(s)
- Jiangjiang Zhang
- Guangdong Provincial Key Laboratory of Advanced Biomaterials, Shenzhen Key Laboratory of Smart Healthcare Engineering, Department of Biomedical Engineering and Department of Hepatobiliary and Pancreas Surgery (The First Affiliated Hospital), Southern University of Science and Technology, No. 1088 Xueyuan Rd., Nanshan District, Shenzhen, Guangdong 518055, P. R. China
| | - Ying Li
- Center for AIE Research, College of Materials Science and Engineering, Shenzhen University, Shenzhen, Guangdong 518060, P. R. China
| | - Fengli Chai
- Guangdong Provincial Key Laboratory of Advanced Biomaterials, Shenzhen Key Laboratory of Smart Healthcare Engineering, Department of Biomedical Engineering and Department of Hepatobiliary and Pancreas Surgery (The First Affiliated Hospital), Southern University of Science and Technology, No. 1088 Xueyuan Rd., Nanshan District, Shenzhen, Guangdong 518055, P. R. China
| | - Qizhen Li
- Guangdong Provincial Key Laboratory of Advanced Biomaterials, Shenzhen Key Laboratory of Smart Healthcare Engineering, Department of Biomedical Engineering and Department of Hepatobiliary and Pancreas Surgery (The First Affiliated Hospital), Southern University of Science and Technology, No. 1088 Xueyuan Rd., Nanshan District, Shenzhen, Guangdong 518055, P. R. China
| | - Dou Wang
- Guangdong Provincial Key Laboratory of Advanced Biomaterials, Shenzhen Key Laboratory of Smart Healthcare Engineering, Department of Biomedical Engineering and Department of Hepatobiliary and Pancreas Surgery (The First Affiliated Hospital), Southern University of Science and Technology, No. 1088 Xueyuan Rd., Nanshan District, Shenzhen, Guangdong 518055, P. R. China
| | - Liping Liu
- Guangdong Provincial Key Laboratory of Advanced Biomaterials, Shenzhen Key Laboratory of Smart Healthcare Engineering, Department of Biomedical Engineering and Department of Hepatobiliary and Pancreas Surgery (The First Affiliated Hospital), Southern University of Science and Technology, No. 1088 Xueyuan Rd., Nanshan District, Shenzhen, Guangdong 518055, P. R. China
- Corresponding author. (X.J.); (B.Z.T.); (L.L.)
| | - Ben Zhong Tang
- Center for AIE Research, College of Materials Science and Engineering, Shenzhen University, Shenzhen, Guangdong 518060, P. R. China
- Shenzhen Institute of Aggregate Science and Technology, School of Science and Engineering, The Chinese University of Hong Kong, Shenzhen, Guangdong, P. R. China
- Corresponding author. (X.J.); (B.Z.T.); (L.L.)
| | - Xingyu Jiang
- Guangdong Provincial Key Laboratory of Advanced Biomaterials, Shenzhen Key Laboratory of Smart Healthcare Engineering, Department of Biomedical Engineering and Department of Hepatobiliary and Pancreas Surgery (The First Affiliated Hospital), Southern University of Science and Technology, No. 1088 Xueyuan Rd., Nanshan District, Shenzhen, Guangdong 518055, P. R. China
- Corresponding author. (X.J.); (B.Z.T.); (L.L.)
| |
Collapse
|
26
|
Zhang T, Ding F, Yang Y, Zhao G, Zhang C, Wang R, Huang X. Research Progress and Future Trends of Microfluidic Paper-Based Analytical Devices in In-Vitro Diagnosis. BIOSENSORS 2022; 12:485. [PMID: 35884289 PMCID: PMC9313202 DOI: 10.3390/bios12070485] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 06/30/2022] [Accepted: 07/01/2022] [Indexed: 12/14/2022]
Abstract
In vitro diagnosis (IVD) has become a hot topic in laboratory research and achievement transformation. However, due to the high cost, and time-consuming and complex operation of traditional technologies, some new technologies are being introduced into IVD, to solve the existing problems. As a result, IVD has begun to develop toward point-of-care testing (POCT), a subdivision field of IVD. The pandemic has made governments and health institutions realize the urgency of accelerating the development of POCT. Microfluidic paper-based analytical devices (μPADs), a low-cost, high-efficiency, and easy-to-operate detection platform, have played a significant role in advancing the development of IVD. μPADs are composed of paper as the core material, certain unique substances as reagents for processing the paper, and sensing devices, as auxiliary equipment. The published reviews on the same topic lack a comprehensive and systematic introduction to μPAD classification and research progress in IVD segmentation. In this paper, we first briefly introduce the origin of μPADs and their role in promoting IVD, in the introduction section. Then, processing and detection methods for μPADs are summarized, and the innovative achievements of μPADs in IVD are reviewed. Finally, we discuss and prospect the upgrade and improvement directions of μPADs, in terms of portability, sensitivity, and automation, to help researchers clarify the progress and overcome the difficulties in subsequent μPAD research.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Xiaowen Huang
- State Key Laboratory of Biobased Material and Green Papermaking, School of Bioengineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China; (T.Z.); (F.D.); (Y.Y.); (G.Z.); (C.Z.); (R.W.)
| |
Collapse
|
27
|
|
28
|
Li X, Cui K, Xiu M, Zhou C, Li L, Zhang J, Hao S, Zhang L, Ge S, Huang Y, Yu J. In situ growth of WO 3/BiVO 4 nanoflowers onto cellulose fibers to construct photoelectrochemical/colorimetric lab-on-paper devices for the ultrasensitive detection of AFP. J Mater Chem B 2022; 10:4031-4039. [PMID: 35506741 DOI: 10.1039/d2tb00297c] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
In this work, novel dual-mode lab-on-paper devices based on in situ grown WO3/BiVO4 heterojunctions onto cellulose fibers, as signal amplification probes, were successfully fabricated by the integration of photoelectrochemical (PEC)/colorimetric analysis technologies into a paper sensing platform for the ultrasensitive detection of alpha-fetoprotein (AFP). Specifically, to achieve an impressive PEC performance of the lab-on-paper device, the WO3/BiVO4 heterojunction was in situ grown onto the surface of cellulose fibers assisted with Au nanoparticle (Au NP) functionalization for enhancing the conductivity of the working zone of the device. With the target concentration increased, more immune conjugates could be captured by the proposed paper photoelectrode, which could lead to a quantitative decrease in the photocurrent intensity, eventually realizing the accurate PEC signal readout. To meet the requirement of end-user application, a colorimetric signal readout system was designed for the lab-on-paper device based on the color reaction of 3,3'5,5'-tetramethylbenzidine (TMB) oxidized by WO3/BiVO4 nanoflowers in the presence of H2O2. Noticeably, it is the first time that the WO3/BiVO4 heterojunction is in situ grown onto cellulose fibers, which enhances the sensitivity in view of both their PEC activity and catalytic ability. By controlling the conversion process of hydrophobicity and hydrophilicity on the lab-on-paper device combined with diverse origami methods, the dual-mode PEC/colorimetric signal output for the ultrasensitive AFP detection was realized. Under optimal conditions, the proposed dual-mode lab-on-paper device could enable the sensitive PEC/colorimetric diagnosis of AFP in the linear range of 0.09-100 ng mL-1 and 5-100 ng mL-1 with the limit of detection of 0.03 and 1.47 ng mL-1, respectively.
Collapse
Affiliation(s)
- Xu Li
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China.
| | - Kang Cui
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China.
| | - Mingzhen Xiu
- School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798, Singapore.
| | - Chenxi Zhou
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China.
| | - Li Li
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China.
| | - Jing Zhang
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China.
| | - Shiji Hao
- School of Materials Science & Engineering, Dongguan University of Technology, Guangdong 523808, P. R. China
| | - Lina Zhang
- Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials, University of Jinan, Jinan, 250022, P. R. China
| | - Shenguang Ge
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China.
| | - Yizhong Huang
- School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798, Singapore.
| | - Jinghua Yu
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China.
| |
Collapse
|
29
|
Wang L, Lin H, Zhang J, Wang J. Phage long tail fiber protein-immobilized magnetic nanoparticles for rapid and ultrasensitive detection of Salmonella. Talanta 2022; 248:123627. [PMID: 35661002 DOI: 10.1016/j.talanta.2022.123627] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 05/26/2022] [Accepted: 05/28/2022] [Indexed: 11/28/2022]
Abstract
There is an urgent need to develop fast and sensitive detection methods for foodborne pathogens. But the conventional culture method that typically requires 2-3 days is not ideal for the rapid analysis. Food samples demonstrate a great challenge for direct detection due to the complex matrix. Hence, we present a new method based on the phage long-tail-fiber proteins (LTF4-a) immobilized magnetic nanoparticles (MNPs) for specific separation and concentration of Salmonella. The LTF4-a-MNP was prepared via the coupling of recombinant LTF4-a with MNPs and used to isolate and enrich Salmonella cells from contaminated food samples. The captured material was further integrated with the direct PCR program for accurate detection of Salmonella. Our study successfully established a new method for detecting contaminated food samples of Salmonella, the overall approach took no more than 3 h, which allowed a detection limit of 7 CFU/mL, demonstrating a promising alternative to the immunomagnetic separation method by replacing antibodies or aptamers, that is compatible with downstream analysis.
Collapse
Affiliation(s)
- Luokai Wang
- Food Safety Laboratory, College of Food Science and Engineering, Ocean University of China, No. 5, Yushan Road, Qingdao, Shandong Province, 266003, PR China
| | - Hong Lin
- Food Safety Laboratory, College of Food Science and Engineering, Ocean University of China, No. 5, Yushan Road, Qingdao, Shandong Province, 266003, PR China
| | - Jing Zhang
- Food Safety Laboratory, College of Food Science and Engineering, Ocean University of China, No. 5, Yushan Road, Qingdao, Shandong Province, 266003, PR China
| | - Jingxue Wang
- Food Safety Laboratory, College of Food Science and Engineering, Ocean University of China, No. 5, Yushan Road, Qingdao, Shandong Province, 266003, PR China.
| |
Collapse
|
30
|
Iles AH, He PJW, Katis IN, Horak P, Eason RW, Sones CL. Optimization of flow path parameters for enhanced sensitivity lateral flow devices. Talanta 2022; 248:123579. [PMID: 35660999 DOI: 10.1016/j.talanta.2022.123579] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 05/17/2022] [Accepted: 05/19/2022] [Indexed: 11/30/2022]
Abstract
Lateral flow devices (LFDs) or lateral flow tests (LFTs) are one of the most widely used biosensor platforms for point-of-care (POC) diagnostics. The basic LFD design has remained largely unchanged since its first appearance, and this has limited LFD use in clinical applications due to a general lack of analytical sensitivity. We report here a comprehensive study of the use of laser-patterned geometric control barriers that influence the flow dynamics within an LFD, with the specific aim of enhancing LFD sensitivity and lowering the limit of detection (LOD). This control of sample flow produces an increase in the time available for optimizing the binding kinetics of the implemented assay. The geometric modification to the flow path is in the form of a constriction that is produced by depositing a photo-sensitive polymer onto the nitrocellulose membrane which when polymerized, creates impermeable barrier walls through the depth of the membrane. Both the position of the constriction within the flow path and the number of constrictions allow for an increase in the sensitivity because of a slower overall flow rate within the test and a larger volume of sample per unit width of the test line. For these high sensitivity LFDs (HS-LFD), through optimization of the constriction position and addition of a second constriction we attained a 62% increase in test line color intensity for the detection of procalcitonin (PCT) and were also able to lower the LOD from 10 ng/mL to 1 ng/mL. In addition, of relevance for future commercial exploitation, this also significantly decreases the antibody consumption per device leading to reduced costs for test production. We have further tested our HS-LFD with contrived human samples, validating its application for future clinical use.
Collapse
Affiliation(s)
- Alice H Iles
- Optoelectronics Research Centre, University of Southampton, SO17 1BJ, UK.
| | - Peijun J W He
- Optoelectronics Research Centre, University of Southampton, SO17 1BJ, UK
| | - Ioannis N Katis
- Optoelectronics Research Centre, University of Southampton, SO17 1BJ, UK
| | - Peter Horak
- Optoelectronics Research Centre, University of Southampton, SO17 1BJ, UK
| | - Robert W Eason
- Optoelectronics Research Centre, University of Southampton, SO17 1BJ, UK
| | - Collin L Sones
- Optoelectronics Research Centre, University of Southampton, SO17 1BJ, UK
| |
Collapse
|
31
|
Panraksa Y, Jang I, Carrell CS, Amin AG, Chailapakul O, Chatterjee D, Henry CS. Simple manipulation of enzyme-linked immunosorbent assay (ELISA) using an automated microfluidic interface. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:1774-1781. [PMID: 35481474 PMCID: PMC9119197 DOI: 10.1039/d2ay00326k] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Among lateral flow immunoassay (LFIA) platforms, enzyme-based LFIAs provide signal amplification to improve sensitivity. However, most enzyme-based LFIAs require multiple timed steps, complicating their utility in point-of-care testing (POCT). Here, we report a microfluidic interface for LFIAs that automates sample, buffer, and reagent addition, greatly simplifying operation while achieving the high analytical stringency associated with more complex assays. The microfluidic interface also maintains the low cost and small footprint of standard LFIAs. The platform is fabricated from a combination of polyester film, double-sided adhesive tape, and nitrocellulose, and fits in the palm of your hand. All reagents are dried on the nitrocellulose to facilitate sequential reagent delivery, and the sample is used as the wash buffer to minimize steps. After the sample addition, a user simply waits 15 min for a colorimetric result. This manuscript discusses the development and optimization of the channel geometry to achieve a simple step enzyme amplified immunoassay. As a proof-of-concept target, we selected lipoarabinomannan (LAM), a WHO identified urinary biomarker of active tuberculosis, to demonstrate the device feasibility and reliability. The results revealed that the device successfully detected LAM in phosphate buffer (PBS) as well as spiked urine samples within 15 min after sample loading. The minimum concentration of color change was achieved at 25 ng mL-1.
Collapse
Affiliation(s)
- Yosita Panraksa
- Mycobacteria Research Laboratories, Department of Microbiology, Immunology and Pathology, Colorado State University, 1682 Campus Delivery, Fort Collins, CO, 80523, USA.
- Program in Biotechnology, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Patumwan, Bangkok, 10330, Thailand
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Patumwan, Bangkok, 10330, Thailand.
| | - Ilhoon Jang
- Department of Chemistry, Colorado State University, CO, USA, 80523.
- Institute of Nano Science and Technology, Hanyang University, Seoul, Korea, 04763
| | - Cody S Carrell
- Department of Chemistry, Colorado State University, CO, USA, 80523.
| | - Anita G Amin
- Mycobacteria Research Laboratories, Department of Microbiology, Immunology and Pathology, Colorado State University, 1682 Campus Delivery, Fort Collins, CO, 80523, USA.
| | - Orawon Chailapakul
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Patumwan, Bangkok, 10330, Thailand.
| | - Delphi Chatterjee
- Mycobacteria Research Laboratories, Department of Microbiology, Immunology and Pathology, Colorado State University, 1682 Campus Delivery, Fort Collins, CO, 80523, USA.
| | - Charles S Henry
- Department of Chemistry, Colorado State University, CO, USA, 80523.
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand
| |
Collapse
|
32
|
The Loan Trinh K, Ri Chae W, Yoon Lee N. Recent advances in the fabrication strategies of paper-based microfluidic devices for rapid detection of bacteria and viruses. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107548] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
33
|
Yakoh A, Mehmeti E, Kalcher K, Chaiyo S. Hand-Operated, Paper-Based Rotational Vertical-Flow Immunosensor for the Impedimetric Detection of α-Fetoprotein. Anal Chem 2022; 94:5893-5900. [PMID: 35394293 DOI: 10.1021/acs.analchem.2c00079] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
This study demonstrates a hand-operated, paper-based rotational vertical-flow immunosensor (rotational VFI) platform requiring fewer pipetting steps, designed for the electrochemical detection of α-fetoprotein with multiple and time-sequenced steps. The platform allows users to perform electrochemical measurements without interference from the convective component of fluid motion, which is unfavorable in most techniques. Users can freely transfer-switch-stop fluid flows by manually rotating the paper disk, evidencing the superior flexibility of this sensor compared to other biosensors. Furthermore, the overall assay duration can be considerably shortened to 9 min. The linear range (LR) is determined to be 0.01-500 ng/mL, with a limit of detection (LOD) of 1.65 pg/mL, and the sensitivity can be significantly enhanced simply by switching off the sample stream to ensure detention at the binding zone (for up to 30 min). This additional step can widen the LR to 0.5 pg/mL, with a LOD of 3.54 fg/mL, which is the lowest detectable level ever reported among paper-based sensors. The advantages of the designed rotational VFI qualify it as a suitable alternative to various biosensors.
Collapse
Affiliation(s)
- Abdulhadee Yakoh
- Institute of Biotechnology and Genetic Engineering, Chulalongkorn University, Bangkok 10330, Thailand
| | - Eda Mehmeti
- UBT-Higher Education Institution, Faculty of Pharmacy, Lagjja Kalabria p.n., 10000 Prishtine, Kosovo
| | - Kurt Kalcher
- Institute of Chemistry, Department of Analytical Chemistry, Karl-Franzens University, Universitätsplatz 1, Graz A-8010, Austria
| | - Sudkate Chaiyo
- Institute of Biotechnology and Genetic Engineering, Chulalongkorn University, Bangkok 10330, Thailand.,Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand
| |
Collapse
|
34
|
Zhang M, Cui X, Li N. Smartphone-based mobile biosensors for the point-of-care testing of human metabolites. Mater Today Bio 2022; 14:100254. [PMID: 35469257 PMCID: PMC9034388 DOI: 10.1016/j.mtbio.2022.100254] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 03/14/2022] [Accepted: 03/31/2022] [Indexed: 11/29/2022] Open
Abstract
Rapid, accurate, portable and quantitative profiling of metabolic biomarkers is of great importance for disease diagnosis and prognosis. The recent development in the optical and electric biosensors based on the smartphone is promising for profiling of metabolites with advantages of rapid, reliability, accuracy, low-cost and multi-analytes analysis capability. In this review, we introduced the optical biosensing platforms including colorimetric, fluorescent and chemiluminescent sensing, and electrochemical biosensing platforms including wired and wireless communication. Challenges and future perspectives desired for reliable, accurate, cost-effective, and multi-functions smartphone-based biosensing systems were also discussed. We envision that such smartphone-based biosensing platforms will allow daily and comprehensive metabolites monitoring in the future, thus unlocking the potential to transform clinical diagnostics into non-clinical self-testing. We also believed that this progress report will encourage future research to develop advanced, integrated and multi-functional smartphone-based Point-of-Care testing (POCT) biosensors for the monitoring and diagnosis as well as personalized treatments of a spectrum of metabolic-disorder related diseases.
Collapse
|
35
|
Charernchai S, Chikae M, Phan TT, Wonsawat W, Hirose D, Takamura Y. Automated Paper-Based Femtogram Sensing Device for Competitive Enzyme-Linked Immunosorbent Assay of Aflatoxin B 1 Using Submicroliter Samples. Anal Chem 2022; 94:5099-5105. [PMID: 35302345 PMCID: PMC8969870 DOI: 10.1021/acs.analchem.1c05401] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Microfluidic paper-based analytical devices (μPADs) are promising biosensors that may be used in a variety of bioanalytical applications. A μPAD for automating the competitive enzyme-linked immunosorbent assay (ELISA) of small-sized target detection at the femtogram level using submicroliter samples is reported in this study. The proposed μPAD was integrated with a sucrose valve to automate the sequential delivery of reagents, providing simple control of reagent delivery time and simple operation. The use of a sample solution dropping location at the zones on the device that had been prepared with an antibody-conjugated enzyme before immersion in a running buffer allowed minimization of sample volume to 0.6 μL, while eliminating the possible loss of a target molecule by adsorption on the membrane, thus improving detection sensitivity. Furthermore, the proposed device was successfully applied to the automation of competitive ELISA for the detection of aflatoxin B1 (AFB1), a potent carcinogen that causes substantial health risks to humans worldwide, with a detection limit of 60 femtograms or 0.1 ng/mL. The method developed in this study provides high sensitivity, small sample volume, on-site and equipment-free measurements, low-cost operation, and user-friendliness. This approach could be used to analyze small-sized molecules in the fields of food safety and quality control, environmental monitoring, and clinical diagnostics.
Collapse
Affiliation(s)
- Sumamal Charernchai
- School of Materials Science, Japan Advanced Institute of Science and Technology, Nomi, Ishikawa 923-1211, Japan
| | - Miyuki Chikae
- School of Materials Science, Japan Advanced Institute of Science and Technology, Nomi, Ishikawa 923-1211, Japan
| | - Tue Trong Phan
- School of Materials Science, Japan Advanced Institute of Science and Technology, Nomi, Ishikawa 923-1211, Japan
| | - Wanida Wonsawat
- Department of Chemistry, Faculty of Science and Technology, Suan Sunandha Rajabhat University, Bangkok 10300, Thailand
| | - Daisuke Hirose
- School of Materials Science, Japan Advanced Institute of Science and Technology, Nomi, Ishikawa 923-1211, Japan
| | - Yuzuru Takamura
- School of Materials Science, Japan Advanced Institute of Science and Technology, Nomi, Ishikawa 923-1211, Japan
| |
Collapse
|
36
|
Lomae A, Preechakasedkit P, Teekayupak K, Panraksa Y, Yukird J, Chailapakul O, Ruecha N. Microfluidic Paper-based Device for Medicinal Diagnosis. Curr Top Med Chem 2022; 22:2282-2313. [PMID: 36330618 DOI: 10.2174/1568026623666221103103211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 09/16/2022] [Accepted: 10/06/2022] [Indexed: 11/06/2022]
Abstract
BACKGROUND The demand for point-of-care testing (POCT) devices has rapidly grown since they offer immediate test results with ease of use, makingthem suitable for home self-testing patients and caretakers. However, the POCT development has faced the challenges of increased cost and limited resources. Therefore, the paper substrate as a low-cost material has been employed to develop a cost-effective POCT device, known as "Microfluidic paper-based analytical devices (μPADs)". This device is gaining attention as a promising tool for medicinal diagnostic applications owing to its unique features of simple fabrication, low cost, enabling manipulation flow (capillarydriven flow), the ability to store reagents, and accommodating multistep assay requirements. OBJECTIVE This review comprehensively examines the fabrication methods and device designs (2D/3D configuration) and their advantages and disadvantages, focusing on updated μPADs applications for motif identification. METHODS The evolution of paper-based devices, starting from the traditional devices of dipstick and lateral flow assay (LFA) with μPADs, has been described. Patterned structure fabrication of each technique has been compared among the equipment used, benefits, and drawbacks. Microfluidic device designs, including 2D and 3D configurations, have been introduced as well as their modifications. Various designs of μPADs have been integrated with many powerful detection methods such as colorimetry, electrochemistry, fluorescence, chemiluminescence, electrochemiluminescence, and SER-based sensors for medicinal diagnosis applications. CONCLUSION The μPADs potential to deal with commercialization in terms of the state-of-the-art of μPADs in medicinal diagnosis has been discussed. A great prototype, which is currently in a reallife application breakthrough, has been updated.
Collapse
Affiliation(s)
- Atchara Lomae
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok, 10330, Thailand
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Rd., Pathumwan, Bangkok, 10330, Thailand
| | - Pattarachaya Preechakasedkit
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Rd., Pathumwan, Bangkok, 10330, Thailand
| | - Kanyapat Teekayupak
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok, 10330, Thailand
| | - Yosita Panraksa
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok, 10330, Thailand
- Mycobacteria Research Laboratories, Department of Microbiology, Immunology, and Pathology, Colorado State University, Fort Collins, CO 80523, United States of America
| | - Jutiporn Yukird
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Rd., Pathumwan, Bangkok, 10330, Thailand
| | - Orawon Chailapakul
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok, 10330, Thailand
| | - Nipapan Ruecha
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok, 10330, Thailand
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Rd., Pathumwan, Bangkok, 10330, Thailand
| |
Collapse
|
37
|
Kumar PS, Bhand S, Das AK, Goel S. Microfluidic paper device with on-site heating to produce reactive peroxide species for enhanced smartphone enabled chemiluminescence signal. Talanta 2022; 236:122858. [PMID: 34635242 DOI: 10.1016/j.talanta.2021.122858] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2021] [Revised: 08/03/2021] [Accepted: 09/05/2021] [Indexed: 01/29/2023]
Abstract
Chemiluminescence signal amplification (CLSA) is of huge interest because of its sensitive detection in various applications such as food analysis, biomedical diagnosis and environmental monitoring. Due to this, there is a manifold attention to develop rapidly prototyped and miniaturized devices for CLSA. In this context, herein, a novel CLSA approach is demonstrated on a 3D printed microfluidic paper-based analytical device (μPADs), fabricated using Fused deposition modeling (FDM) printing technology. Influence of working temperature, ranging 30 °C-110 °C, on CL signal generation from well-established Luminol/Co+2 - H2O2 reaction was analyzed using a screen-printed flexible heater onto the 3D printed reaction platform. A smartphone-based capturing/detection system provided the amenability for a point-of-care testing system. For the first time, strong and stable CLSA was found with about 255% ± 5% increase in its signal intensity without using any additional external enhancers. The on-site working temperature was directly in proportional to the intensity of CL signal generated from Luminol/Co+2 - H2O2 reaction under optimum conditions, wherein the device had a wide linear range from 50 nM to 1 μM with a detection limit of 35 nM for H2O2 detection. The reliability of the developed amplification method was tested for practicability to detect the concentration of H2O2 in milk as real sample analysis. Overall, such CLSA mechanism in miniaturized μPADs will have strong potential for multiple CL based detection and monitoring application.
Collapse
Affiliation(s)
- Pavar Sai Kumar
- MEMS, Microfluidics and Nano Electronics Laboratory, Department of Electrical and Electronics Engineering, Birla Institute of Technology and Science Pilani, Hyderabad Campus, Hyderabad, 500078, India
| | - Sunil Bhand
- Department of Chemistry, Birla Institute of Technology and Science Pilani, Goa Campus, Goa, 403726, India
| | - Ashis Kumar Das
- Department of Biological Sciences, Birla Institute of Technology and Science Pilani, Pilani Campus, Pilani, 333031, India
| | - Sanket Goel
- MEMS, Microfluidics and Nano Electronics Laboratory, Department of Electrical and Electronics Engineering, Birla Institute of Technology and Science Pilani, Hyderabad Campus, Hyderabad, 500078, India.
| |
Collapse
|
38
|
Khamcharoen W, Kaewjua K, Yomthiangthae P, Anekrattanasap A, Chailapakul O, Siangproh W. Recent Developments in Microfluidic Paper-based Analytical Devices for Pharmaceutical Analysis. Curr Top Med Chem 2022; 22:2241-2260. [PMID: 36305123 DOI: 10.2174/1568026623666221027144310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 09/29/2022] [Accepted: 10/12/2022] [Indexed: 11/22/2022]
Abstract
In the last decade, due to the global increase in diseases, drugs for biomedical applications have increased dramatically. Therefore, there is an urgent need for analytical tools to monitor, treat, investigate, and control drug compounds in diverse matrices. The new and challenging task has been looking for simple, low-cost, rapid, and portable analytical platforms. The development of microfluidic paper-based analytical devices (μPADs) has garnered immense attention in many analytical applications due to the benefit of cellulose structure. It can be functionalized and serves as an ideal channel and scaffold for the transportation and immobilization of various substances. Microfluidic technology has been considered an effective tool in pharmaceutical analysis that facilitates the quantitative measurement of several parameters on cells or other biological systems. The μPADs represent unique advantages over conventional microfluidics, such as the self-pumping capability. They have low material costs, are easy to fabricate, and do not require external power sources. This review gives an overview of the current designs in this decade for μPADs and their respective application in pharmaceutical analysis. These include device designs, choice of paper material, and fabrication techniques with their advantages and drawbacks. In addition, the strategies for improving analytical performance in terms of simplicity, high sensitivity, and selectivity are highlighted, followed by the application of μPADs design for the detection of drug compounds for various purposes. Moreover, we present recent advances involving μPAD technologies in the field of pharmaceutical applications. Finally, we discussed the challenges and potential of μPADs for the transition from laboratory to commercialization.
Collapse
Affiliation(s)
- Wisarut Khamcharoen
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand
| | - Kantima Kaewjua
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand
| | - Phanumas Yomthiangthae
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand
| | - Ananyaporn Anekrattanasap
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand
| | - Orawon Chailapakul
- Electrochemistry and Optical Spectroscopy Center of Excellence, Department of Chemistry, Faculty of Science, Chulalongkorn University, Pathumwan, Bangkok, 10330, Thailand
| | - Weena Siangproh
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Wattana, Bangkok, 10110, Thailand
| |
Collapse
|
39
|
Advanced trap lateral flow immunoassay sensor for the detection of cortisol in human bodily fluids. Sci Rep 2021; 11:22580. [PMID: 34799635 PMCID: PMC8604903 DOI: 10.1038/s41598-021-02084-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Accepted: 11/09/2021] [Indexed: 11/08/2022] Open
Abstract
Paper-based biosensors based on lateral flow immunoassay (LFI) are promising candidates for POC diagnosis because of their ease of use and rapid target detection. However, the low sensitivity of LFI limits its application, and signal amplification has been used in numerous studies to increase its sensitivity. We developed an advanced trap LFI (α-trapLFI), a simple-to-use sensor, with an additional step for signal amplification. Here, signal amplification is automatically implemented following delayed release of enhancement solution induced by water-soluble polyvinyl alcohol tape. As the polyvinyl alcohol tape is exposed to water, its polymer structure is perturbed (within 5 min), allowing ions to pass through. This new sensor was designed to have a short time delay between the flow of solutions used for the immunoassay and signal amplification. The α-trapLFI was subsequently used to detect cortisol with high sensitivity (9.1 pg∙mL-1) over a broad detection range (0.01-1000 ng∙mL-1) in bodily fluids. Furthermore, an excellent correlation was obtained by analyzing 20 human real saliva samples using this sensor and a conventional ELISA (R2 = 0.90). The new sensor will be helpful in detecting various small molecules for simple, rapid, and portable POC diagnosis of stress disorders.
Collapse
|
40
|
Pumpless three-dimensional photo paper-based microfluidic analytical device for automatic detection of thioredoxin-1 using enzyme-linked immunosorbent assay. Anal Bioanal Chem 2021; 414:3219-3230. [PMID: 34767053 DOI: 10.1007/s00216-021-03747-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Revised: 09/28/2021] [Accepted: 10/21/2021] [Indexed: 10/19/2022]
Abstract
Microfluidic-based biosensors have been developed for their precise automatic reaction control. However, these biosensors require external devices that are difficult to transport and use. To overcome this disadvantage, our group made an easy-to-use, cheap, and light pumpless three-dimensional photo paper-based microfluidic analytical device (3D-μPAD; weight: 1.5 g). Unlike conventional paper-based microfluidic analytical devices, the 3D-μPAD can be used to control fluid flow in a 3D manner, thus allowing sophisticated multi-step reaction control. This device can control fluid flow speed and direction accurately using only the capillary-driven flow without an external device like a pump. The flow speed is controlled by the width of the microfluidic channel and its surface property. In addition, fluid speed control and 3D-bridge structure enable the control of fluid flow direction. Using these methods, multi-step enzyme-linked immunosorbent assay (ELISA) can be done automatically in sequence by injecting solutions (sample, washing, and enzyme's substrate) at the same time in the 3D-μPAD. All the steps can be performed in 14 min, and data can be analyzed immediately. To test this device, thioredoxin-1 (Trx-1), a biomarker of breast cancer, is used as the target. In the 3D-μPAD, it can detect 0-200 ng/mL of Trx-1, and the prepared 3D-μPAD Trx-1 sensor displays excellent selectivity. Moreover, by analyzing the concentration of Trx-1 in real patients and healthy individuals' blood serum samples using the 3D-μPAD, and comparing results to ELISA, it can be confirmed that the 3D-μPAD is a good tool for cancer diagnosis.
Collapse
|
41
|
Wang E, Guo Z, Tang R, Lo YH. Using airflow-driven, evaporative gradients to improve sensitivity and fluid control in colorimetric paper-based assays. LAB ON A CHIP 2021; 21:4249-4261. [PMID: 34608465 DOI: 10.1039/d1lc00542a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Microfluidic paper-based analytical devices (μPADs) are foundational devices for point-of-care testing, yet suffer from limitations in regards to their sensitivity and capability in handling complex assays. Here, we demonstrate an airflow-based, evaporative method that is capable of manipulating fluid flows within paper membranes to offer new functionalities for multistep delivery of reagents and improve the sensitivity of μPADs by 100-1000 times. This method applies an air-jet to a pre-wetted membrane, generating an evaporative gradient such that any solutes become enriched underneath the air-jet spot. By controlling the lateral position of this spot, the solutes in the paper strip are enriched and follow the air jet trajectory, driving the reactions and enhancing visualization for colorimetric readout in multistep assays. The technique has been successfully applied to drive the sequential delivery in multistep immunoassays as well as improve sensitivity for colorimetric detection assays for nucleic acids and proteins via loop-mediated isothermal amplification (LAMP) and ELISA. For colorimetric LAMP detection of the COVID-19 genome, enrichment of the solution on paper could enhance the contrast of the dye in order to more clearly distinguish between the positive and negative results to achieve a sensitivity of 3 copies of SARS-Cov-2 RNAs. For ELISA, enrichment of the oxidized TMB substrate yielded a sensitivity increase of two-to-three orders of magnitude when compared to non-enriched samples - having a limit of detection of around 200 fM for IgG. Therefore, this enrichment method represents a simple process that can be easily integrated into existing detection assays for controlling fluid flows and improving detection of biomarkers on paper.
Collapse
Affiliation(s)
- Edward Wang
- Department of Aerospace and Mechanical Engineering, Materials Science and Engineering Program, UC-San Diego, San Diego, USA.
| | - Zhilin Guo
- Department of Aerospace and Mechanical Engineering, Materials Science and Engineering Program, UC-San Diego, San Diego, USA.
| | - Rui Tang
- Department of Electrical and Computer Engineering, UC-San Diego, San Diego, USA
| | - Yu-Hwa Lo
- Department of Aerospace and Mechanical Engineering, Materials Science and Engineering Program, UC-San Diego, San Diego, USA.
- Department of Electrical and Computer Engineering, UC-San Diego, San Diego, USA
| |
Collapse
|
42
|
You T, Jeong W, Lee H, Huh YS, Kim SM, Jeon TJ. A simple strategy for signal enhancement in lateral flow assays using superabsorbent polymers. Mikrochim Acta 2021; 188:364. [PMID: 34613450 DOI: 10.1007/s00604-021-05026-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Accepted: 09/11/2021] [Indexed: 10/20/2022]
Abstract
To enhance the sensitivity of lateral flow assays (LFAs), a simple strategy is proposed using a nitrocellulose membrane modified with a superabsorbent polymer (SAP). SAP was incorporated into a nitrocellulose membrane for the flow control of detection probes. When absorbing aqueous solutions, SAP promoted the formation of biomolecule complexes to achieve up to a tenfold sensitivity improvement for the detection of human IgG. The assay time was optimized experimentally and numerically to within 20 min using this strategy. Moreover, fluid saturation in LFAs modified with SAP was mathematically simulated to better understand the underlying process, and molecular dynamics simulations were carried out to determine the effect of SAP. The proposed design was also applied to samples spiked with human immunoglobulin-depleted serum to test its applicability. The strategy presented is unique in that it preserves the characteristics of conventional LFAs, as it minimizes user intervention and is simple to manufacture at scale.
Collapse
Affiliation(s)
- Taeyeong You
- Department of Biological Sciences and Bioengineering, Inha University, Incheon, 22212, South Korea.,Biohybrid Systems Research Center (BSRC), Inha University, Incheon, 22212, South Korea
| | - Woojin Jeong
- Department of Biological Sciences and Bioengineering, Inha University, Incheon, 22212, South Korea.,Biohybrid Systems Research Center (BSRC), Inha University, Incheon, 22212, South Korea
| | - Hwankyu Lee
- Department of Chemical Engineering, Dankook University, Yongin, 16890, South Korea
| | - Yun Suk Huh
- Department of Biological Sciences and Bioengineering, Inha University, Incheon, 22212, South Korea. .,Biohybrid Systems Research Center (BSRC), Inha University, Incheon, 22212, South Korea. .,Department of Biological Engineering, Inha University, Incheon, 22212, South Korea.
| | - Sun Min Kim
- Department of Biological Sciences and Bioengineering, Inha University, Incheon, 22212, South Korea. .,Biohybrid Systems Research Center (BSRC), Inha University, Incheon, 22212, South Korea. .,Department of Mechanical Engineering, Inha University, Incheon, 22212, South Korea.
| | - Tae-Joon Jeon
- Department of Biological Sciences and Bioengineering, Inha University, Incheon, 22212, South Korea. .,Biohybrid Systems Research Center (BSRC), Inha University, Incheon, 22212, South Korea. .,Department of Biological Engineering, Inha University, Incheon, 22212, South Korea.
| |
Collapse
|
43
|
Cai Q, Wang R, Qiao Z, Yang W. Single-digit Salmonella detection with the naked eye using bio-barcode immunoassay coupled with recombinase polymerase amplification and a CRISPR-Cas12a system. Analyst 2021; 146:5271-5279. [PMID: 34355716 DOI: 10.1039/d1an00717c] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The ability to visually detect low numbers of Salmonella in food samples is highly valuable but remains a challenge. Here we present a novel platform for ultrasensitive and visual detection of Salmonella Typhimurium by integrating the bio-barcode immunoassay (BCA), recombinase polymerase amplification (RPA), and CRISPR-Cas12a cleavage in a single reaction system (termed as BCA-RPA-Cas12a). In the system, the target bacteria were separated by immunomagnetic nanoparticles and labeled with numerous barcode AuNPs, which carry abundant bio-barcode DNA molecules to amplify the signal. Afterwards, the bio-barcode DNA molecules were amplified by RPA and subsequently triggered the cleavage activity of Cas12a to generate the fluorescence signal. Due to this triplex signal amplification, the BCA-RPA-Cas12a system can selectively detect Salmonella Typhimurium at the single-digit level with the naked eye under blue light within 60 min. Meanwhile, this novel platform was successfully applied to detect Salmonella Typhimurium in spiked milk samples with a similar sensitivity and satisfactory recovery, indicating its potential application in real samples. Furthermore, in virtue of the versatility of the antibody in the stage of BCA, the BCA-RPA-Cas12a system can be extended to further application in other bacteria detection and food safety monitoring.
Collapse
Affiliation(s)
- Qiqi Cai
- College of Food and Pharmaceutical Sciences, Ningbo University, Ningbo 315800, China.
| | | | | | | |
Collapse
|
44
|
A simple label-free electrochemical sensor for sensitive detection of alpha-fetoprotein based on specific aptamer immobilized platinum nanoparticles/carboxylated-graphene oxide. Sci Rep 2021; 11:13969. [PMID: 34234187 PMCID: PMC8263621 DOI: 10.1038/s41598-021-93399-y] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Accepted: 06/17/2021] [Indexed: 11/08/2022] Open
Abstract
A label-free electrochemical aptamer-based sensor has been fabricated for alpha-fetoprotein (AFP) detection. Platinum nanoparticles on carboxylated-graphene oxide (PtNPs/GO-COOH) modified screen-printed graphene-carbon paste electrode (SPGE) was utilized as an immobilization platform, and the AFP aptamer was employed as a bio-recognition element. The synthesized GO-COOH helps to increase the surface area and amounts of the immobilized aptamer. Subsequently, PtNPs are decorated on GO-COOH to enhance electrical conductivity and an oxidation current of the hydroquinone electrochemical probe. The aptamer selectively interacts with AFP, causing a decrease in the peak current of the hydroquinone because the binding biomolecules on the electrode surface hinder the electron transfer of the redox probe. Effects of aptamer concentration and AFP incubation time were studied, and the current changes of the redox probe before and after AFP binding were investigated by square wave voltammetry. The developed aptasensor provides a linear range from 3.0–30 ng mL−1 with a detection limit of 1.22 ng mL−1. Moreover, the aptamer immobilized electrode offers high selectivity to AFP molecules, good stability, and sensitive determination of AFP in human serum samples with high recoveries.
Collapse
|
45
|
Li L, Liang D, Guo W, Tang D, Zeng Y. Antibody‐invertase Cross‐linkage Nanoparticles: A New Signal Tag for Point‐of‐Care Immunoassay of Alpha‐fetoprotein for Hepatocellular Carcinoma with Personal Glucometer. ELECTROANAL 2021. [DOI: 10.1002/elan.202100212] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
- Ling Li
- The First Clinical Medical College of Fujian Medical University Fuzhou 350004 P. R. China
- Mengchao Hepatobiliary Hospital of Fujian Medical University Fuzhou 350025 P. R. China
- Hepatopancreatobiliary Surgery Department The First Affiliated Hospital of Fujian Medical University Fuzhou 350004 P. R. China
| | - Dong Liang
- Mengchao Hepatobiliary Hospital of Fujian Medical University Fuzhou 350025 P. R. China
- People's Hospital Affiliated of Fujian University of Traditional Chinese Medicine Fuzhou 350004 P. R. China
| | - Wuhua Guo
- Mengchao Hepatobiliary Hospital of Fujian Medical University Fuzhou 350025 P. R. China
| | - Dianping Tang
- Department of Chemistry Fuzhou University Fuzhou 350108 P. R. China
| | - Yongyi Zeng
- The First Clinical Medical College of Fujian Medical University Fuzhou 350004 P. R. China
- Mengchao Hepatobiliary Hospital of Fujian Medical University Fuzhou 350025 P. R. China
- Hepatopancreatobiliary Surgery Department The First Affiliated Hospital of Fujian Medical University Fuzhou 350004 P. R. China
| |
Collapse
|
46
|
Strip modification and alternative architectures for signal amplification in nanoparticle-based lateral flow assays. Anal Bioanal Chem 2021; 413:4111-4117. [PMID: 34036400 DOI: 10.1007/s00216-021-03421-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 05/12/2021] [Accepted: 05/19/2021] [Indexed: 10/21/2022]
Abstract
Nanoparticle (NP)-based lateral flow assay (LFA) technology has outstanding characteristics that make it ideal for point-of-care bioanalytical applications. However, LFAs still have important limitations, especially related to sensitivity, which is in general worse than that of other well-established bioassays such as ELISA or PCR. Many efforts have been made for enhancing the sensitivity of LFAs, mainly actuating on the nanoparticle labels and on alternative optical detection modes. However, strip pads modification for such a purpose is an incipient vast field of research. This article gives a brief overview on the recent advances proposed for signal amplification actuating on different pads and the general architecture of the LFA strips. Such strategies offer universal tools that can be adapted to any LFA, independently of the kind of sample, analyte, and label. The principles of the different strategies developed to achieve novel signal amplification and sensitive detection are discussed, and some examples of relevant approaches are highlighted, together with future prospects and challenges.
Collapse
|
47
|
You M, Peng P, Xue Z, Tong H, He W, Mao P, Liu Q, Yao C, Xu F. A fast and ultrasensitive ELISA based on rolling circle amplification. Analyst 2021; 146:2871-2877. [PMID: 33899835 DOI: 10.1039/d1an00355k] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
A highly sensitive ELISA is critical for early diagnosis and biomarker discovery of various diseases. Although various ELISA technologies have been developed with high sensitivity, they are limited by poor repeatability, high cost, the dependence on complex equipment and/or a prolonged reaction time. To this end, we developed a fast and ultrasensitive ELISA (termed RELISA) based on rolling circle amplification (RCA) and enzymatic signal amplification. The RELISA is established on the traditional ELISA, with only one more RCA step that can be accomplished within 10 minutes. The prolonged single strand DNA (ssDNA) from RCA is able to enrich abundant horseradish peroxidase conjugate (HRP) modified detection probes. Consequently, the intensive HRP is able to catalyze TMB-H2O2 to produce significantly enhanced colorimetric signals. With CEACAM-7 as a model biomarker, the RELISA achieves the limit of detection as low as 2.82 pg mL-1, which is ∼50 times higher than that of the traditional ELISA. Therefore, we envision that the developed RELISA would be a powerful tool for the early diagnosis of various major diseases.
Collapse
Affiliation(s)
- Minli You
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, P.R. China. and Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an 710049, P.R. China
| | - Ping Peng
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, P.R. China. and Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an 710049, P.R. China and Department of Transfusion Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P.R. China.
| | - Zhenrui Xue
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, P.R. China. and Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an 710049, P.R. China and Department of Transfusion Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P.R. China.
| | - Haoyang Tong
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, P.R. China. and Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an 710049, P.R. China
| | - Wanghong He
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, P.R. China. and Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an 710049, P.R. China and Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, P.R. China
| | - Ping Mao
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, P.R. China. and Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an 710049, P.R. China and Department of Transfusion Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P.R. China.
| | - Qi Liu
- Department of Transfusion Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P.R. China.
| | - Chunyan Yao
- Department of Transfusion Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, P.R. China. and State Key Laboratory of Trauma, Burn and Combined Injury, Third Military Medical University, Chongqing, 400038, P.R. China
| | - Feng Xu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, P.R. China. and Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an 710049, P.R. China
| |
Collapse
|
48
|
Modha S, Castro C, Tsutsui H. Recent developments in flow modeling and fluid control for paper-based microfluidic biosensors. Biosens Bioelectron 2021; 178:113026. [PMID: 33545552 DOI: 10.1016/j.bios.2021.113026] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 12/31/2020] [Accepted: 01/19/2021] [Indexed: 12/30/2022]
Abstract
Over the last 10 years, researchers have shown that paper is a promising substrate for affordable biosensors. The field of paper-microfluidics has evolved rapidly in that time, with simple colorimetric assays giving way to more complex electrochemical devices that can handle multiple samples at a given time. As paper devices become more complex, the ability to precisely control different fluids simultaneously becomes a challenge. Specifically, automated flow control is a necessary attribute to make paper-based devices more useable in resource-limited settings. Flow control strategies on paper are typically developed experimentally through trial-and-error, with little focus on theory. This is because flow behavior in paper is not well understood and sometimes difficult to predict precisely. Additionally, popular theoretical models are too simplistic, making them unsuitable for complex device designs and application conditions. A better understanding of flow theory would allow devices conceived straight from theoretical models. This could save time and resources by reducing experimental work. In this review, we provide an overview of different theoretical models used to characterize imbibition in paper substrates and document the latest flow control strategies that have been applied to automated fluid control on paper. Additionally, we look at current efforts to commercialize paper-based devices along with challenges facing this industry.
Collapse
Affiliation(s)
- Sidharth Modha
- Department of Bioengineering, University of California, Riverside, Riverside, CA, 92521, USA
| | - Carlos Castro
- Department of Mechanical Engineering, California State Polytechnic University, Pomona, Pomona, CA, 91768, USA
| | - Hideaki Tsutsui
- Department of Bioengineering, University of California, Riverside, Riverside, CA, 92521, USA; Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, 92521, USA; Stem Cell Center, University of California, Riverside, Riverside, CA, 92521, USA.
| |
Collapse
|
49
|
The steadfast Au@Pt soldier: Peroxide-tolerant nanozyme for signal enhancement in lateral flow immunoassay of peroxidase-containing samples. Talanta 2021; 225:121961. [DOI: 10.1016/j.talanta.2020.121961] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 11/25/2020] [Accepted: 11/30/2020] [Indexed: 02/05/2023]
|
50
|
Ng JS, Hashimoto M. 3D-PAD: Paper-Based Analytical Devices with Integrated Three-Dimensional Features. BIOSENSORS 2021; 11:84. [PMID: 33802637 PMCID: PMC8002416 DOI: 10.3390/bios11030084] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 02/14/2021] [Accepted: 02/16/2021] [Indexed: 11/16/2022]
Abstract
This paper describes the use of fused deposition modeling (FDM) printing to fabricate paper-based analytical devices (PAD) with three-dimensional (3D) features, which is termed as 3D-PAD. Material depositions followed by heat reflow is a standard approach for the fabrication of PAD. Such devices are primarily two-dimensional (2D) and can hold only a limited amount of liquid samples in the device. This constraint can pose problems when the sample consists of organic solvents that have low interfacial energies with the hydrophobic barriers. To overcome this limitation, we developed a method to fabricate PAD integrated with 3D features (vertical walls as an example) by FDM 3D printing. 3D-PADs were fabricated using two types of thermoplastics. One thermoplastic had a low melting point that formed hydrophobic barriers upon penetration, and another thermoplastic had a high melting point that maintained 3D features on the filter paper without reflowing. We used polycaprolactone (PCL) for the former, and polylactic acid (PLA) for the latter. Both PCL and PLA were printed with FDM without gaps at the interface, and the resulting paper-based devices possessed hydrophobic barriers consisting of PCL seamlessly integrated with vertical features consisting of PLA. We validated the capability of 3D-PAD to hold 30 μL of solvents (ethanol, isopropyl alcohol, and acetone), all of which would not be retained on conventional PADs fabricated with solid wax printers. To highlight the importance of containing an increased amount of liquid samples, a colorimetric assay for the formation of dimethylglyoxime (DMG)-Ni (II) was demonstrated using two volumes (10 μL and 30 μL) of solvent-based dimethylglyoxime (DMG). FDM printing of 3D-PAD enabled the facile construction of 3D structures integrated with PAD, which would find applications in paper-based chemical and biological assays requiring organic solvents.
Collapse
Affiliation(s)
- James S. Ng
- Pillar of Engineering Product Development, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore;
| | - Michinao Hashimoto
- Pillar of Engineering Product Development, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore;
- SUTD-MIT International Design Centre, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore
- Digital Manufacturing and Design Centre, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore
| |
Collapse
|