1
|
Baskar A, Madhivanan K, Atchudan R, Arya S, Sundramoorthy AK. Nanoparticle electrochemical biosensors for virus detection. Clin Chim Acta 2025; 566:120054. [PMID: 39551230 DOI: 10.1016/j.cca.2024.120054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2024] [Revised: 11/14/2024] [Accepted: 11/14/2024] [Indexed: 11/19/2024]
Abstract
Viruses pose a significant threat to global public health, underscoring the urgent need for rapid, accurate, and sensitive diagnostic methods for timely detection and intervention. The demand for efficient diagnostics that can detect a wide range of viral pathogens has never been greater. In this context, metal nanoparticle-based biosensors have emerged as a promising solution, offering exceptional sensitivity for detecting various analytes, including nucleic acids (DNA/RNA), proteins, and other biomarkers associated with pathogens. These biosensors are particularly critical for the development of point-of-care (POC) diagnostic tools, enabling early detection of infectious agents. This review explores recent advancements in nanoparticle (NP)-based biosensors that utilize noble metals like gold (Au), silver (Ag), and platinum (Pt) for viral pathogen detection, focusing on viruses such as SARS-CoV, HIV, hepatitis, influenza, and Zika. It highlights the role of NP-based electrochemical sensors and compares traditional and contemporary detection techniques. The review also examines key performance metrics such as limits of detection (LOD), linear detection ranges, cost-effectiveness, and accessibility, with a special emphasis on their application in POC diagnostics. The aim is to provide researchers with valuable insights into the development of next-generation NP-based biosensors, facilitating the creation of innovative diagnostic technologies for viral diseases.
Collapse
Affiliation(s)
- Anandavalli Baskar
- Centre for Nano-Biosensors, Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai, 600077, Tamil Nadu, India
| | - Keerthana Madhivanan
- Centre for Nano-Biosensors, Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai, 600077, Tamil Nadu, India
| | - Raji Atchudan
- School of Chemical Engineering, Yeungnam University, Gyeongsan, 38541, Republic of Korea
| | - Sandeep Arya
- Department of Physics, University of Jammu, Jammu, Jammu and Kashmir, 180006, India
| | - Ashok K Sundramoorthy
- Centre for Nano-Biosensors, Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai, 600077, Tamil Nadu, India.
| |
Collapse
|
2
|
Nyenhuis J, Heuer C, Bahnemann J. 3D Printing in Biocatalysis and Biosensing: From General Concepts to Practical Applications. Chem Asian J 2024; 19:e202400717. [PMID: 39340791 PMCID: PMC11639642 DOI: 10.1002/asia.202400717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2024] [Revised: 09/25/2024] [Accepted: 09/27/2024] [Indexed: 09/30/2024]
Abstract
3D printing has matured into a versatile technique that offers researchers many different printing methods and materials with varying properties. Nowadays, 3D printing is deployed within a myriad of different applications, ranging from chemistry to biotechnology -including bioanalytics, biocatalysis or biosensing. Due to its inherent design flexibility (which enables rapid prototyping) and ease of use, 3D printing facilitates the relatively quick and easy creation of new devices with unprecedented functions.. This review article describes how 3D printing can be employed for research in the fields of biochemistry and biotechnology, and specifically for biocatalysis and biosensor applications. We survey different relevant 3D printing techniques, as well as the surface activation and functionalization of 3D-printed materials. Finally, we show how 3D printing is used for the fabrication of reaction ware and enzymatic assays in biocatalysis research, as well as for the generation of biosensors using aptamers, antibodies, and enzymes as recognition elements.
Collapse
Affiliation(s)
- Jonathan Nyenhuis
- Institute of PhysicsChair of Technical BiologyUniversity of AugsburgUniversitätsstr. 1Augsburg86159Germany
| | - Christopher Heuer
- Institute of PhysicsChair of Technical BiologyUniversity of AugsburgUniversitätsstr. 1Augsburg86159Germany
- Institute of PhysicsCentre for Advanced Analytics and Predictive SciencesUniversity of AugsburgUniversitätsstr. 1Augsburg86159Germany
| | - Janina Bahnemann
- Institute of PhysicsChair of Technical BiologyUniversity of AugsburgUniversitätsstr. 1Augsburg86159Germany
- Institute of PhysicsCentre for Advanced Analytics and Predictive SciencesUniversity of AugsburgUniversitätsstr. 1Augsburg86159Germany
| |
Collapse
|
3
|
Lei Y, Sala X, García-Antón J, Muñoz J. Versatile Organometallic Synthesis of 0D/2D Metal@Germanane Nanoarchitectonics for Electrochemical Energy Conversion Applications. SMALL METHODS 2024:e2400854. [PMID: 39533450 DOI: 10.1002/smtd.202400854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2024] [Revised: 10/30/2024] [Indexed: 11/16/2024]
Abstract
Hydrogen-terminated 2D-Germanane (2D-GeH), a germanium-based 2D material akin to graphene, is receiving enormous attention owing to its predicted optoelectronic characteristics. However, experimental research of 2D-GeH is still in an early stage, and therefore its real implementation for task-specific applications will depend on the correct development of suitable chemical functionalization methods. Herein, a general and straightforward organometallic (OM) approach is provided for the robust functionalization of 2D-GeH with different 0D noble metal nanoparticles (M-NPs), resulting in 0D/2D M@GeH nanoarchitectonics. As a proof-of-principle, 0D/2D Pt@GeH and Au@GeH nanoarchitectonics have been successfully synthesized, characterized, and explored as unconventional electrocatalysts for boosting energy conversion reactions. While the hydrogen evolution reaction activity was evaluated for Pt@GeH, the oxygen reduction reaction was interrogated for Au@GeH. Interestingly, the implanted catalytic features of M-NPs yielded to 0D/2D M@GeH nanoarchitectonics with enhanced energy conversion activity comparing to pristine 2D-GeH counterpart. This work proves the suitability of 2D-GeH as unconventional substrates to stabilize nobleM-NPs, and the versatility of the OM approach for the custom design of a new family of 0D/2D M@GeH nanoarchitectonics to expand the implementation of monoelemental 2D materials as promising electrocatalysts in energy conversion field and beyond.
Collapse
Affiliation(s)
- Yiming Lei
- Departament de Química, Universitat Autònoma de Barcelona, Cerdanyola del Vallès (Barcelona), 08193, Spain
| | - Xavier Sala
- Departament de Química, Universitat Autònoma de Barcelona, Cerdanyola del Vallès (Barcelona), 08193, Spain
| | - Jordi García-Antón
- Departament de Química, Universitat Autònoma de Barcelona, Cerdanyola del Vallès (Barcelona), 08193, Spain
| | - Jose Muñoz
- Departament de Química, Universitat Autònoma de Barcelona, Cerdanyola del Vallès (Barcelona), 08193, Spain
| |
Collapse
|
4
|
Silva MVCO, Carvalho MS, Silva LRG, Rocha RG, Cambraia LV, Janegitz BC, Nossol E, Muñoz RAA, Richter EM, Stefano JS. Tailoring 3D-printed sensor properties with reduced-graphene oxide: improved conductive filaments. Mikrochim Acta 2024; 191:633. [PMID: 39342530 DOI: 10.1007/s00604-024-06720-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2024] [Accepted: 09/19/2024] [Indexed: 10/01/2024]
Abstract
The development of a tailored filament is reported composed of reduced graphene oxide (rGO) and carbon black (CB) in a polylactic acid (PLA) matrix and its use in the production of electrochemical sensors. The electrodes containing rGO showed superior performance when compared with those prepared in the absence of this material. Physicochemical and electrochemical characterizations of the electrodes showed the successful incorporation of both rGO and CB and an improved conductivity in the presence of rGO (lower resistance to charge transfer). As a proof-of-concept, the developed electrodes were applied to the detection of the forensic analytes TNT and cocaine. The electrodes containing rGO presented a superior analytical performance for both TNT and cocaine detection, showing the lower limit of detection values (0.22 and 2.1 µmol L-1, respectively) in comparison with pure CB-PLA electrodes (0.93 and 11.3 µmol L-1, respectively). Besides, better-defined redox peaks were observed, especially for TNT, as well as increased sensitivity for both molecules.
Collapse
Affiliation(s)
- Michele V C O Silva
- Institute of Chemistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, 38400-902, Brazil
| | - Mayane S Carvalho
- Institute of Chemistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, 38400-902, Brazil
| | - Luiz R G Silva
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, Araras, São Paulo, 13600-970, Brazil
| | - Raquel G Rocha
- Institute of Chemistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, 38400-902, Brazil
| | - Luciana V Cambraia
- Technology Center in Nanomaterials and Graphene (CTNano/UFMG), Federal University of Minas Gerais, Belo Horizonte, 31310-260, Brazil
| | - Bruno C Janegitz
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, Araras, São Paulo, 13600-970, Brazil
| | - Edson Nossol
- Institute of Chemistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, 38400-902, Brazil.
| | - Rodrigo A A Muñoz
- Institute of Chemistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, 38400-902, Brazil.
| | - Eduardo M Richter
- Institute of Chemistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, 38400-902, Brazil.
| | - Jéssica S Stefano
- Institute of Chemistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, 38400-902, Brazil.
| |
Collapse
|
5
|
Crapnell RD, Banks CE. Electroanalysis overview: additive manufactured biosensors using fused filament fabrication. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2625-2634. [PMID: 38639065 DOI: 10.1039/d4ay00278d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/20/2024]
Abstract
Additive manufacturing (3D-printing), in particular fused filament fabrication, presents a potential paradigm shift in the way electrochemical based biosensing platforms are produced, giving rise to a new generation of personalized and on-demand biosensors. The use of additive manufactured biosensors is unparalleled giving rise to unique customization, facile miniaturization, ease of use, economical but yet, still providing sensitive and selective approaches towards the target analyte. In this mini review, we focus on the use of fused filament fabrication additive manufacturing technology alongside different biosensing approaches that exclusively use antibodies, enzymes and associated biosensing materials (mediators) providing an up-to-date overview with future considerations to expand the additive manufacturing biosensors field.
Collapse
Affiliation(s)
- Robert D Crapnell
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, UK.
| | - Craig E Banks
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, UK.
| |
Collapse
|
6
|
Orzari LO, Silva LRGE, de Freitas RC, Brazaca LC, Janegitz BC. Lab-made disposable screen-printed electrochemical sensors and immunosensors modified with Pd nanoparticles for Parkinson's disease diagnostics. Mikrochim Acta 2024; 191:76. [PMID: 38172448 DOI: 10.1007/s00604-023-06158-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 12/15/2023] [Indexed: 01/05/2024]
Abstract
A new conductive ink based on the addition of carbon black to a poly(vinyl alcohol) matrix is developed and investigated for electrochemical sensing and biosensing applications. The produced devices were characterized using morphological and electrochemical techniques and modified with Pd nanoparticles to enhance electrical conductivity and reaction kinetics. With the aid of chemometrics, the parameters for metal deposition were investigated and the sensor was applied to the determination of Parkinson's disease biomarkers, specifically epinephrine and α-synuclein. A linear behavior was obtained in the range 0.75 to 100 μmol L-1 of the neurotransmitter, and the device displayed a limit of detection (LOD) of 0.051 μmol L-1. The three-electrode system was then tested using samples of synthetic cerebrospinal fluid. Afterward, the device was modified with specific antibodies to quantify α-synuclein using electrochemical impedance spectroscopy. In phosphate buffer, a linear range was obtained for α-synuclein concentrations from 1.5 to 15 μg mL-1, with a calculated LOD of 0.13 μg mL-1. The proposed immunosensor was also applied to blood serum samples, and, in this case, the linear range was observed from 6.0 to 100.5 μg mL-1 of α-synuclein, with a LOD = 1.3 µg mL-1. Both linear curves attend the range for the real diagnosis, demonstrating its potential application to complex matrices.
Collapse
Affiliation(s)
- Luiz Otávio Orzari
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, Araras, SP, 13600-970, Brazil
- Department of Physics, Chemistry and Mathematics, Federal University of São Carlos, Sorocaba, SP, 18052-780, Brazil
| | - Luiz Ricardo Guterres E Silva
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, Araras, SP, 13600-970, Brazil
- Department of Physics, Chemistry and Mathematics, Federal University of São Carlos, Sorocaba, SP, 18052-780, Brazil
| | - Rafaela Cristina de Freitas
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, Araras, SP, 13600-970, Brazil
- Department of Physics, Chemistry and Mathematics, Federal University of São Carlos, Sorocaba, SP, 18052-780, Brazil
| | - Laís Canniatti Brazaca
- São Carlos Institute of Chemistry, University of São Paulo, São Carlos, SP, 13566-590, Brazil
| | - Bruno Campos Janegitz
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, Araras, SP, 13600-970, Brazil.
| |
Collapse
|
7
|
Parupelli SK, Desai S. The 3D Printing of Nanocomposites for Wearable Biosensors: Recent Advances, Challenges, and Prospects. Bioengineering (Basel) 2023; 11:32. [PMID: 38247910 PMCID: PMC10813523 DOI: 10.3390/bioengineering11010032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 12/11/2023] [Accepted: 12/20/2023] [Indexed: 01/23/2024] Open
Abstract
Notably, 3D-printed flexible and wearable biosensors have immense potential to interact with the human body noninvasively for the real-time and continuous health monitoring of physiological parameters. This paper comprehensively reviews the progress in 3D-printed wearable biosensors. The review also explores the incorporation of nanocomposites in 3D printing for biosensors. A detailed analysis of various 3D printing processes for fabricating wearable biosensors is reported. Besides this, recent advances in various 3D-printed wearable biosensors platforms such as sweat sensors, glucose sensors, electrocardiography sensors, electroencephalography sensors, tactile sensors, wearable oximeters, tattoo sensors, and respiratory sensors are discussed. Furthermore, the challenges and prospects associated with 3D-printed wearable biosensors are presented. This review is an invaluable resource for engineers, researchers, and healthcare clinicians, providing insights into the advancements and capabilities of 3D printing in the wearable biosensor domain.
Collapse
Affiliation(s)
- Santosh Kumar Parupelli
- Department of Industrial and Systems Engineering, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA;
- Center of Excellence in Product Design and Advanced Manufacturing, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA
| | - Salil Desai
- Department of Industrial and Systems Engineering, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA;
- Center of Excellence in Product Design and Advanced Manufacturing, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA
| |
Collapse
|
8
|
Wang R, Du Y, Fu Y, Guo Y, Gao X, Guo X, Wei J, Yang Y. Ceria-Based Nanozymes in Point-of-Care Diagnosis: An Emerging Futuristic Approach for Biosensing. ACS Sens 2023; 8:4442-4467. [PMID: 38091479 DOI: 10.1021/acssensors.3c01692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2023]
Abstract
In recent years, there has been a notable increase in interest surrounding nanozymes due to their ability to imitate the functions and address the limitations of natural enzymes. The scientific community has been greatly intrigued by the study of nanoceria, primarily because of their distinctive physicochemical characteristics, which include a variety of enzyme-like activities, affordability, exceptional stability, and the ability to easily modify their surfaces. Consequently, nanoceria have found extensive use in various biosensing applications. However, the impact of its redox activity on the enzymatic catalytic mechanism remains a subject of debate, as conflicting findings in the literature have presented both pro-oxidant and antioxidant effects. Herein, we creatively propose a seesaw model to clarify the regulatory mechanism on redox balance and survey possible mechanisms of multienzyme mimetic properties of nanoceria. In addition, this review aims to showcase the latest advancements in this field by systematically discussing over 180 research articles elucidating the significance of ceria-based nanozymes in enhancing, downsizing, and enhancing the efficacy of point-of-care (POC) diagnostics. These advancements align with the ASSURED criteria established by the World Health Organization (WHO). Furthermore, this review also examines potential constraints in order to offer readers a concise overview of the emerging role of nanoceria in the advancement of POC diagnostic systems for future biosensing applications.
Collapse
Affiliation(s)
- Ruixue Wang
- College of Biological and Chemical Engineering, Qilu Institute of Technology, Jinan 250200, P. R. China
| | - Yuanyuan Du
- College of Biological and Chemical Engineering, Qilu Institute of Technology, Jinan 250200, P. R. China
| | - Ying Fu
- College of Biological and Chemical Engineering, Qilu Institute of Technology, Jinan 250200, P. R. China
| | - Yingxin Guo
- College of Biological and Chemical Engineering, Qilu Institute of Technology, Jinan 250200, P. R. China
| | - Xing Gao
- College of Biological and Chemical Engineering, Qilu Institute of Technology, Jinan 250200, P. R. China
| | - Xingqi Guo
- State Key Laboratory of Crop Biology, College of Life Sciences, Shandong Agricultural University, Taian 271018, P. R. China
| | - Jingjing Wei
- School of Chemistry and Chemical Engineering, Shandong University, Jinan 250200, P. R. China
| | - Yanzhao Yang
- School of Chemistry and Chemical Engineering, Shandong University, Jinan 250200, P. R. China
| |
Collapse
|
9
|
Tay RY, Song Y, Yao DR, Gao W. Direct-Ink-Writing 3D-Printed Bioelectronics. MATERIALS TODAY (KIDLINGTON, ENGLAND) 2023; 71:135-151. [PMID: 38222250 PMCID: PMC10786343 DOI: 10.1016/j.mattod.2023.09.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2024]
Abstract
The development of wearable and implantable bioelectronics has garnered significant momentum in recent years, driven by the ever-increasing demand for personalized health monitoring, remote patient management, and real-time physiological data collection. The elevated sophistication and advancement of these devices have thus led to the use of many new and unconventional materials which cannot be fulfilled through traditional manufacturing techniques. Three-dimension (3D) printing, also known as additive manufacturing, is an emerging technology that opens new opportunities to fabricate next-generation bioelectronic devices. Some significant advantages include its capacity for material versatility and design freedom, rapid prototyping, and manufacturing efficiency with enhanced capabilities. This review provides an overview of the recent advances in 3D printing of bioelectronics, particularly direct ink writing (DIW), encompassing the methodologies, materials, and applications that have emerged in this rapidly evolving field. This review showcases the broad range of bioelectronic devices fabricated through 3D printing including wearable biophysical sensors, biochemical sensors, electrophysiological sensors, energy devices, multimodal systems, implantable devices, and soft robots. This review will also discuss the advantages, existing challenges, and outlook of applying DIW 3D printing for the development of bioelectronic devices toward healthcare applications.
Collapse
Affiliation(s)
- Roland Yingjie Tay
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, California, 91125, USA
- School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
| | - Yu Song
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, California, 91125, USA
| | - Dickson R. Yao
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, California, 91125, USA
| | - Wei Gao
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, California, 91125, USA
| |
Collapse
|
10
|
Wu J, Liang B, Lu S, Xie J, Song Y, Wang L, Gao L, Huang Z. Application of 3D printing technology in tumor diagnosis and treatment. Biomed Mater 2023; 19:012002. [PMID: 37918002 DOI: 10.1088/1748-605x/ad08e1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Accepted: 11/01/2023] [Indexed: 11/04/2023]
Abstract
3D printing technology is an increasing approach consisting of material manufacturing through the selective incremental delamination of materials to form a 3D structure to produce products. This technology has different advantages, including low cost, short time, diversification, and high precision. Widely adopted additive manufacturing technologies enable the creation of diagnostic tools and expand treatment options. Coupled with its rapid deployment, 3D printing is endowed with high customizability that enables users to build prototypes in shorts amounts of time which translates into faster adoption in the medical field. This review mainly summarizes the application of 3D printing technology in the diagnosis and treatment of cancer, including the challenges and the prospects combined with other technologies applied to the medical field.
Collapse
Affiliation(s)
- Jinmei Wu
- School of Artificial Intelligence and Information Technology, Nanjing University of Chinese Medicine, No. 138 Xianling Rd., Nanjing 210023, Jiangsu, People's Republic of China
- School of Chemistry and Chemical Engineering, Guangxi Minzu University, No.158, University West Road, Nanning 530000, Guangxi, People's Republic of China
| | - Bing Liang
- School of Artificial Intelligence and Information Technology, Nanjing University of Chinese Medicine, No. 138 Xianling Rd., Nanjing 210023, Jiangsu, People's Republic of China
- School of Chemistry and Chemical Engineering, Guangxi Minzu University, No.158, University West Road, Nanning 530000, Guangxi, People's Republic of China
| | - Shuoqiao Lu
- School of Chemistry and Chemical Engineering, Guangxi Minzu University, No.158, University West Road, Nanning 530000, Guangxi, People's Republic of China
| | - Jinlan Xie
- School of Chemistry and Chemical Engineering, Guangxi Minzu University, No.158, University West Road, Nanning 530000, Guangxi, People's Republic of China
| | - Yan Song
- China Automotive Engineering Research Institute Co., Ltd (CAERI), Chongqing 401122, People's Republic of China
| | - Lude Wang
- School of Artificial Intelligence and Information Technology, Nanjing University of Chinese Medicine, No. 138 Xianling Rd., Nanjing 210023, Jiangsu, People's Republic of China
| | - Lingfeng Gao
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, Hangzhou 311121, Zhejiang, People's Republic of China
| | - Zaiyin Huang
- School of Chemistry and Chemical Engineering, Guangxi Minzu University, No.158, University West Road, Nanning 530000, Guangxi, People's Republic of China
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, Hangzhou 311121, Zhejiang, People's Republic of China
| |
Collapse
|
11
|
Ferreira LMC, Reis IF, Martins PR, Marcolino-Junior LH, Bergamini MF, Camargo JR, Janegitz BC, Vicentini FC. Using low-cost disposable immunosensor based on flexible PET screen-printed electrode modified with carbon black and gold nanoparticles for sensitive detection of SARS-CoV-2. TALANTA OPEN 2023; 7:100201. [PMID: 36959870 PMCID: PMC9998283 DOI: 10.1016/j.talo.2023.100201] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 03/02/2023] [Accepted: 03/05/2023] [Indexed: 03/12/2023] Open
Abstract
To help meet the global demand for reliable and inexpensive COVID-19 testing and environmental analysis of SARS-CoV-2, the present work reports the development and application of a highly efficient disposable electrochemical immunosensor for the detection of SARS-CoV-2 in clinical and environmental matrices. The sensor developed is composed of a screen-printed electrode (SPE) array which was constructed using conductive carbon ink printed on polyethylene terephthalate (PET) substrate made from disposable soft drink bottles. The recognition site (Spike S1 Antibody (anti-SP Ab)) was covalently immobilized on the working electrode surface, which was effectively modified with carbon black (CB) and gold nanoparticles (AuNPs). The immunosensing material was subjected to a multi-technique characterization analysis using X-ray diffraction (XRD), transmission electron microscopy (TEM), and scanning electron microscopy (SEM) with elemental analysis via energy dispersive spectroscopy (EDS). The electrochemical characterization of the electrode surface and analytical measurements were performed using cyclic voltammetry (CV) and square-wave voltammetry (SWV). The immunosensor was easily applied for the conduct of rapid diagnoses or accurate quantitative environmental analyses by setting the incubation period to 10 min or 120 min. Under optimized conditions, the biosensor presented limits of detection (LODs) of 101 fg mL-1 and 46.2 fg mL-1 for 10 min and 120 min incubation periods, respectively; in addition, the sensor was successfully applied for SARS-CoV-2 detection and quantification in clinical and environmental samples. Considering the costs of all the raw materials required for manufacturing 200 units of the AuNP-CB/PET-SPE immunosensor, the production cost per unit is 0.29 USD.
Collapse
Affiliation(s)
- Luís M C Ferreira
- Center of Nature Sciences, Federal University of São Carlos, Rod. Lauri Simões de Barros km 12, 18290-000, Buri, SP, Brazil
| | - Isabela F Reis
- Center of Nature Sciences, Federal University of São Carlos, Rod. Lauri Simões de Barros km 12, 18290-000, Buri, SP, Brazil
| | - Paulo R Martins
- Institute of Chemistry, Federal University of Goiás, Av. Esperança, Goiania, GO 74690-900, Brazil
| | - Luiz H Marcolino-Junior
- Laboratory of Electrochemical Sensors (LabSensE) - Department of Chemistry, Federal University of Paraná, 81.531-980, Curitiba, PR, Brazil
| | - Marcio F Bergamini
- Laboratory of Electrochemical Sensors (LabSensE) - Department of Chemistry, Federal University of Paraná, 81.531-980, Curitiba, PR, Brazil
| | - Jessica R Camargo
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, 13600-970, Araras, SP, Brazil
| | - Bruno C Janegitz
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, 13600-970, Araras, SP, Brazil
| | - Fernando C Vicentini
- Center of Nature Sciences, Federal University of São Carlos, Rod. Lauri Simões de Barros km 12, 18290-000, Buri, SP, Brazil
| |
Collapse
|
12
|
Graphene-based 3D-Printed nanocomposite bioelectronics for monitoring breast cancer cell adhesion. Biosens Bioelectron 2023; 226:115113. [PMID: 36764127 DOI: 10.1016/j.bios.2023.115113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 01/11/2023] [Accepted: 01/28/2023] [Indexed: 02/05/2023]
Abstract
This work examines the suitability of graphene-based 3D-printed nanocomposite bioelectronics as innovative systems to in situ monitor and evaluate both breast cancer cell adhesion and the chemosensitivity of anti-cancer drugs. With this aim, 3D-printed nanocomposite graphene electrodes (3D-nGEs) -made of a commercially available graphene/polylactic acid filament- have been covalently biofunctionalized with an extracellular matrix protein (i.e., fibronectin) by exploiting the carbon reactivity of 3D-nGEs. The specificity and selectivity of the developed electrochemical system to monitor breast cancer cell adhesion has been tested via electrochemical impedance spectroscopy (EIS). Importantly, the resulting 3D-printed bioelectronic system displayed excellent accuracy for the rapid screening of anti-cancer drugs, which exactly corresponded with the results achieved by the standard optical method, while having the advantage of employing a label-free approach. In light of the current state-of-the-art in the field, this proof-of-concept connects electronics to biological systems within 3D printing technology, providing the bases for the sustainable and cost-effective manufacturing of graphene-based 3D-printed nanocomposite bioelectronics to simulate in vivo microenvironments using in situ and real time electronic output signals.
Collapse
|
13
|
Liu C, Staples R, Gómez-Cerezo MN, Ivanovski S, Han P. Emerging Technologies of Three-Dimensional Printing and Mobile Health in COVID-19 Immunity and Regenerative Dentistry. Tissue Eng Part C Methods 2023; 29:163-182. [PMID: 36200626 DOI: 10.1089/ten.tec.2022.0160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
The ongoing coronavirus disease 2019 (COVID-19) pandemic highlights the importance of developing point-of-care (POC) antibody tests for monitoring the COVID-19 immune response upon viral infection or following vaccination, which requires three key aspects to achieve optimal monitoring, including three-dimensional (3D)-printed POC devices, mobile health (mHealth), and noninvasive sampling. As a critical tissue engineering concept, additive manufacturing (AM, also known as 3D printing) enables accurate control over the dimensional and architectural features of the devices. mHealth refers to the use of portable digital devices, such as smartphones, tablet computers, and fitness and medical wearables, to support health, which facilitates contact tracing, and telehealth consultations during the pandemic. Compared with invasive biosample (blood), saliva is of great importance in the spread and surveillance of COVID-19 as a noninvasive diagnostic method for virus detection and immune status monitoring. However, investigations into 3D-printed POC antibody test and mHealth using noninvasive saliva are relatively limited. Further exploration of 3D-printed antibody POC tests and mHealth applications to monitor antibody production for either disease onset or immune response following vaccination is warranted. This review briefly describes the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus and immune response after infection and vaccination, then discusses current widely used binding antibody tests using blood samples and enzyme-linked immunosorbent assays on two-dimensional microplates before focusing upon emerging POC technological platforms, such as field-effect transistor biosensors, lateral flow assay, microfluidics, and AM for fabricating immunoassays, and the possibility of their combination with mHealth. This review proposes that noninvasive biofluid sampling combined with 3D POC antibody tests and mHealth technologies is a promising and novel approach for POC detection and surveillance of SARS-CoV-2 immune response. Furthermore, as key concepts in dentistry, the application of 3D printing and mHealth was also included to facilitate the appreciation of cutting edge techniques in regenerative dentistry. This review highlights the potential of 3D printing and mHealth in both COVID-19 immunity monitoring and regenerative dentistry.
Collapse
Affiliation(s)
- Chun Liu
- School of Dentistry, The University of Queensland, Brisbane, Queensland, Australia
- Center for Oral-Facial Regeneration, Rehabilitation and Reconstruction (COR3), School of Dentistry, The University of Queensland, Brisbane, Queensland, Australia
| | - Reuben Staples
- Center for Oral-Facial Regeneration, Rehabilitation and Reconstruction (COR3), School of Dentistry, The University of Queensland, Brisbane, Queensland, Australia
| | - Maria Natividad Gómez-Cerezo
- Center for Oral-Facial Regeneration, Rehabilitation and Reconstruction (COR3), School of Dentistry, The University of Queensland, Brisbane, Queensland, Australia
| | - Sašo Ivanovski
- School of Dentistry, The University of Queensland, Brisbane, Queensland, Australia
- Center for Oral-Facial Regeneration, Rehabilitation and Reconstruction (COR3), School of Dentistry, The University of Queensland, Brisbane, Queensland, Australia
| | - Pingping Han
- School of Dentistry, The University of Queensland, Brisbane, Queensland, Australia
- Center for Oral-Facial Regeneration, Rehabilitation and Reconstruction (COR3), School of Dentistry, The University of Queensland, Brisbane, Queensland, Australia
| |
Collapse
|
14
|
Alafeef M, Skrodzki D, Moitra P, Gunaseelan N, Pan D. Binding-Induced Folding of DNA Oligonucleotides Targeted to the Nucleocapsid Gene Enables Electrochemical Sensing of SARS-CoV-2. ACS APPLIED BIO MATERIALS 2023; 6:1133-1145. [PMID: 36877613 PMCID: PMC9999945 DOI: 10.1021/acsabm.2c00984] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 02/19/2023] [Indexed: 03/07/2023]
Abstract
In the wake of the COVID-19 pandemic, millions of confirmed cases and deaths have been reported around the world. COVID-19 spread can be slowed and eventually stopped by a rapid test to diagnose positive cases of the disease on the spot. It is still important to test for COVID-19 quickly regardless of the availability of the vaccine. Using the binding-induced folding principle, we developed an electrochemical test for detecting SARS-CoV-2 with no RNA extraction or nucleic acid amplification. The test showed high sensitivity with a limit of detection of 2.5 copies/μL. An electrode mounted with a capture probe and a portable potentiostat are used to conduct the test. To target the N-gene of SARS-CoV-2, a highly specific oligo-capturing probe was used. Based on the binding-induced "folding" principle, the sensor detects binding between the oligo and RNA. When the target is absent, the capture probe tends to form a hairpin as a secondary structure, retaining the redox reporter close to the surface. This can be seen as a large anodic and cathodic peak current. When the target RNA is present, the hairpin structure will open to hybridize with its complementary sequence, causing the redox reporter to pull away from the electrode. Consequently, the anodic/cathodic peak currents are reduced, indicating the presence of the SARS-CoV-2 genetic material. Validation of the test performance was performed using 122 COVID-19 clinical samples (55 positives and 67 negatives) and benchmarked to the gold standard reverse transcription-polymerase chain reaction (RT-PCR) test. As a result of our test, the accuracy, sensitivity, and specificity have been measured at 98.4%, 98.2%, and 98.5%, respectively.
Collapse
Affiliation(s)
- Maha Alafeef
- Bioengineering
Department, The University of Illinois at
Urbana-Champaign, Urbana, Illinois 61801, United States
- Departments
of Diagnostic Radiology and Nuclear Medicine and Pediatrics, Center
for Blood Oxygen Transport and Hemostasis, Health Sciences Research
Facility III, University of Maryland School
of Medicine, 670 W Baltimore
Street, Baltimore, Maryland 21201, United States
- Biomedical
Engineering Department, Jordan University
of Science and Technology, Irbid 22110, Jordan
- Department
of Chemical, Biochemical and Environmental Engineering, University of Maryland, Baltimore County, Baltimore, Maryland 21250, United States
- Department
of Nuclear Engineering, Pennsylvania State
University, State
College, Pennsylvania 16801, United States
| | - David Skrodzki
- Department
of Materials Science and Engineering, Pennsylvania
State University, State College, Pennsylvania 16801, United States
| | - Parikshit Moitra
- Department
of Nuclear Engineering, Pennsylvania State
University, State
College, Pennsylvania 16801, United States
| | - Nivetha Gunaseelan
- Biomedical
Engineering Department, Pennsylvania State
University, State College, Pennsylvania 16801, United States
| | - Dipanjan Pan
- Bioengineering
Department, The University of Illinois at
Urbana-Champaign, Urbana, Illinois 61801, United States
- Departments
of Diagnostic Radiology and Nuclear Medicine and Pediatrics, Center
for Blood Oxygen Transport and Hemostasis, Health Sciences Research
Facility III, University of Maryland School
of Medicine, 670 W Baltimore
Street, Baltimore, Maryland 21201, United States
- Department
of Chemical, Biochemical and Environmental Engineering, University of Maryland, Baltimore County, Baltimore, Maryland 21250, United States
- Department
of Nuclear Engineering, Pennsylvania State
University, State
College, Pennsylvania 16801, United States
- Department
of Materials Science and Engineering, Pennsylvania
State University, State College, Pennsylvania 16801, United States
- Biomedical
Engineering Department, Pennsylvania State
University, State College, Pennsylvania 16801, United States
| |
Collapse
|
15
|
Dhangar M, Chaturvedi K, Mili M, Patel SS, Khan MA, Bhargaw HN, Srivastava AK, Verma S. Emerging
3D
printed thermal insulating materials for sustainable approach: A review and a way forward. POLYM ADVAN TECHNOL 2023. [DOI: 10.1002/pat.5989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Affiliation(s)
- Manish Dhangar
- Industrial Waste Utilization, Nano and Biomaterials (IWUN&B), Council of Scientific and Industrial Research ‐ Advanced Materials and Processes Research Institute Bhopal (M.P.) India
| | - Kamna Chaturvedi
- Industrial Waste Utilization, Nano and Biomaterials (IWUN&B), Council of Scientific and Industrial Research ‐ Advanced Materials and Processes Research Institute Bhopal (M.P.) India
- AcSIR ‐ Advanced Materials and Processes Research Institute (AMPRI) Bhopal (M.P.) India
| | - Medha Mili
- AcSIR ‐ Advanced Materials and Processes Research Institute (AMPRI) Bhopal (M.P.) India
- Green Engineered Materials And Additive Manufacturing (GEMAM), Council of Scientific and Industrial Research ‐ Advanced Materials and Processes Research Institute Bhopal (M.P.) India
| | - Shiv Singh Patel
- AcSIR ‐ Advanced Materials and Processes Research Institute (AMPRI) Bhopal (M.P.) India
- Water Resources Management and Rural Technology, Council of Scientific and Industrial Research ‐ Advanced Materials and Processes Research Institute Bhopal (M.P.) India
| | - Mohammed Akram Khan
- Industrial Waste Utilization, Nano and Biomaterials (IWUN&B), Council of Scientific and Industrial Research ‐ Advanced Materials and Processes Research Institute Bhopal (M.P.) India
- AcSIR ‐ Advanced Materials and Processes Research Institute (AMPRI) Bhopal (M.P.) India
| | - Hari Narayan Bhargaw
- AcSIR ‐ Advanced Materials and Processes Research Institute (AMPRI) Bhopal (M.P.) India
- Intelligent Materials and Advanced Processes. Council of Scientific and Industrial Research ‐ Advanced Materials and Processes Research Institute Bhopal (M.P.) India
| | - Avanish Kumar Srivastava
- AcSIR ‐ Advanced Materials and Processes Research Institute (AMPRI) Bhopal (M.P.) India
- Council of Scientific and Industrial Research ‐ Advanced Materials and Processes Research Institute, Hoshangabad Road Bhopal (M.P.) India
| | - Sarika Verma
- Industrial Waste Utilization, Nano and Biomaterials (IWUN&B), Council of Scientific and Industrial Research ‐ Advanced Materials and Processes Research Institute Bhopal (M.P.) India
- AcSIR ‐ Advanced Materials and Processes Research Institute (AMPRI) Bhopal (M.P.) India
| |
Collapse
|
16
|
Weerasuriya DRK, Hiniduma K, Bhakta S, Nigro LM, Posada LF, Tan H, Suib SL, Kremer R, Rusling JF. COVID-19 Detection Using a 3D-Printed Micropipette Tip and a Smartphone. ACS Sens 2023; 8:848-857. [PMID: 36689276 PMCID: PMC9888406 DOI: 10.1021/acssensors.2c02516] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 12/27/2022] [Indexed: 01/24/2023]
Abstract
The COVID-19 pandemic has caused over 7 million deaths worldwide and over 1 million deaths in the US as of October 15, 2022. Virus testing lags behind the level or availability necessary for pandemic events like COVID-19, especially in resource-limited settings. Here, we report a low cost, mix-and-read COVID-19 assay using a synthetic SARS-CoV-2 sensor, imaged and processed using a smartphone. The assay was optimized for saliva and employs 3D-printed micropipette tips with a layer of monoclonal anti-SARS-CoV-2 inside the tip. A polymeric sensor for SARS-CoV-2 spike (S) protein (COVRs) synthesized as a thin film on silica nanoparticles provides 3,3',5-5'-tetramethylbenzidine responsive color detection using streptavidin-poly-horseradish peroxidase (ST-poly-HRP) with 400 HRP labels per molecule. COVRs were engineered with an NHS-PEG4-biotin coating to reduce nonspecific binding and provide affinity for ST-poly-HRP labels. COVRs binds to S-proteins with binding strengths and capacities much larger than salivary proteins in 10% artificial saliva-0.01%-Triton X-100 (as virus deactivator). A limit of detection (LOD) of 200 TCID50/mL (TCID50 = tissue culture infectious dose 50%) in artificial saliva was obtained using the Color Grab smartphone app and verified using ImageJ. Viral load values obtained in 10% pooled human saliva spiked with inactivated SARS-COV-2 virus gave excellent correlation with viral loads obtained from qPCR (p = 0.0003, r = 0.99).
Collapse
Affiliation(s)
- D. Randil K. Weerasuriya
- Department of Chemistry, University of
Connecticut, Storrs, Connecticut06269-3060, United
States
| | - Keshani Hiniduma
- Department of Chemistry, University of
Connecticut, Storrs, Connecticut06269-3060, United
States
| | - Snehasis Bhakta
- Department of Chemistry, Cooch Behar
College, Cooch Behar, WB736101, India
| | - Lisa M. Nigro
- Microbial Analysis, Resources and Services, Center for
Open Research Resources and Equipment, University of
Connecticut, Storrs, Connecticut06269-3032, United
States
- Institute for Systems Genomics,
University of Connecticut, Storrs, Connecticut06269-3003,
United States
| | - Luisa F. Posada
- Department of Chemistry, University of
Connecticut, Storrs, Connecticut06269-3060, United
States
| | - Haiyan Tan
- Innovation Partnership Building at UConn Tech Park,
University of Connecticut, Storrs, Connecticut06269,
United States
| | - Steven L. Suib
- Department of Chemistry, University of
Connecticut, Storrs, Connecticut06269-3060, United
States
- Institute of Materials Science,
University of Connecticut, Storrs, Connecticut06269-3136,
United States
| | - Richard Kremer
- Department of Medicine, McGill University Health
Centre, 1001 Decarie Blvd., Montreal, QCH4A,
Canada
| | - James F. Rusling
- Department of Chemistry, University of
Connecticut, Storrs, Connecticut06269-3060, United
States
- Institute of Materials Science,
University of Connecticut, Storrs, Connecticut06269-3136,
United States
- Department of Surgery and Neag Cancer Center,
Uconn Health, Farmington, Connecticut06030, United
States
- School of Chemistry, National University
of Ireland at Galway, GalwayH91 TK33, Ireland
| |
Collapse
|
17
|
Hao W, Huang Y, Wang L, Liang J, Yang S, Su L, Zhang X. Smartphone-Based Photothermal Lateral Flow Immunoassay Using Rhenium Diselenide Nanosheet. ACS APPLIED MATERIALS & INTERFACES 2023; 15:9665-9674. [PMID: 36780303 PMCID: PMC9940616 DOI: 10.1021/acsami.2c22616] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 01/31/2023] [Indexed: 06/18/2023]
Abstract
Developing a rapid antibody-based detection method is of great importance for preventing and controlling the spread of coronavirus disease 2019 (COVID-19). Among the antibody-based methods for point-of-care (POC) detection, lateral flow immunoassay (LFIA) is the most widely used. However, LFIA still has the disadvantage of low sensitivity. In this work, an ReSe2 nanosheet with a thickness of 10-20 nm was prepared by liquid exfoliation and applied as the label in a photothermal LFIA due to its high photothermal conversion efficiency and high photothermal stability. An integrated detection device was introduced for rapid, on-site, and highly sensitive assay of the human antisevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Spike (S) protein IgG antibodies. The device mainly included a rhenium diselenide (ReSe2) nanosheet-based photothermal LFIA, a portable laser, and a smartphone with a portable thermal imager, which was used to record and analyze the thermal signal of the LFIA test zone. The human anti-SARS-COV-2 S protein IgG antibodies in buffer solution can be detected in a portable box within 10 min, with a thermal signal detection limit of 0.86 ng mL-1, which was 108-fold lower than that of the colorimetric signal. The integrated device can detect values as low as 2.76 ng mL-1 of the human anti-SARS-COV-2 S protein IgG antibodies in 50% serum. The integrated device showed great potential for rapid and home self-testing diagnosis of COVID-19.
Collapse
Affiliation(s)
- Wenbin Hao
- Beijing
Key Laboratory for Bioengineering and Sensing Technology, School of
Chemistry and Biological Engineering; Beijing Advanced Innovation
Center for Materials Genome Engineering, School of Materials Science
and Engineering, University of Science &
Technology Beijing, Beijing 100083, P. R. China
| | - Yan Huang
- Beijing
Key Laboratory for Bioengineering and Sensing Technology, School of
Chemistry and Biological Engineering; Beijing Advanced Innovation
Center for Materials Genome Engineering, School of Materials Science
and Engineering, University of Science &
Technology Beijing, Beijing 100083, P. R. China
| | - Lei Wang
- Beijing
Key Laboratory for Bioengineering and Sensing Technology, School of
Chemistry and Biological Engineering; Beijing Advanced Innovation
Center for Materials Genome Engineering, School of Materials Science
and Engineering, University of Science &
Technology Beijing, Beijing 100083, P. R. China
| | - Jing Liang
- Beijing
Key Laboratory for Bioengineering and Sensing Technology, School of
Chemistry and Biological Engineering; Beijing Advanced Innovation
Center for Materials Genome Engineering, School of Materials Science
and Engineering, University of Science &
Technology Beijing, Beijing 100083, P. R. China
| | - ShuangShuang Yang
- Beijing
Key Laboratory for Bioengineering and Sensing Technology, School of
Chemistry and Biological Engineering; Beijing Advanced Innovation
Center for Materials Genome Engineering, School of Materials Science
and Engineering, University of Science &
Technology Beijing, Beijing 100083, P. R. China
| | - Lei Su
- School
of Biomedical Engineering, Shenzhen University
Health Science Center, Shenzhen 518060, China
| | - Xueji Zhang
- School
of Biomedical Engineering, Shenzhen University
Health Science Center, Shenzhen 518060, China
| |
Collapse
|
18
|
Tan S, Zhang Z, Xue Y, Zhao J, Ji J, Wang C, Wu Y. Ionic Liquid Cross-linked Poly( N-isopropylacrylamide) Hydrogel Electrolytes for Self-Protective Flexible Separator-Free Supercapacitors. Ind Eng Chem Res 2023. [DOI: 10.1021/acs.iecr.2c04363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- Shuai Tan
- School of Chemical Engineering, Sichuan University, Chengdu610045, China
| | - Zechuan Zhang
- School of Chemical Engineering, Sichuan University, Chengdu610045, China
| | - Yuzhen Xue
- School of Chemical Engineering, Sichuan University, Chengdu610045, China
| | - Jingli Zhao
- School of Chemical Engineering, Sichuan University, Chengdu610045, China
| | - Junyi Ji
- School of Chemical Engineering, Sichuan University, Chengdu610045, China
| | - Caihong Wang
- School of Chemical Engineering, Sichuan University, Chengdu610045, China
| | - Yong Wu
- School of Chemical Engineering, Sichuan University, Chengdu610045, China
| |
Collapse
|
19
|
Blasques RV, de Oliveira PR, Kalinke C, Brazaca LC, Crapnell RD, Bonacin JA, Banks CE, Janegitz BC. Flexible Label-Free Platinum and Bio-PET-Based Immunosensor for the Detection of SARS-CoV-2. BIOSENSORS 2023; 13:190. [PMID: 36831956 PMCID: PMC9954080 DOI: 10.3390/bios13020190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 01/14/2023] [Accepted: 01/20/2023] [Indexed: 06/18/2023]
Abstract
The demand for new devices that enable the detection of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) at a relatively low cost and that are fast and feasible to be used as point-of-care is required overtime on a large scale. In this sense, the use of sustainable materials, for example, the bio-based poly (ethylene terephthalate) (Bio-PET) can be an alternative to current standard diagnostics. In this work, we present a flexible disposable printed electrode based on a platinum thin film on Bio-PET as a substrate for the development of a sensor and immunosensor for the monitoring of COVID-19 biomarkers, by the detection of L-cysteine and the SARS-CoV-2 spike protein, respectively. The electrode was applied in conjunction with 3D printing technology to generate a portable and easy-to-analyze device with a low sample volume. For the L-cysteine determination, chronoamperometry was used, which achieved two linear dynamic ranges (LDR) of 3.98-39.0 μmol L-1 and 39.0-145 μmol L-1, and a limit of detection (LOD) of 0.70 μmol L-1. The detection of the SARS-CoV-2 spike protein was achieved by both square wave voltammetry (SWV) and electrochemical impedance spectroscopy (EIS) by a label-free immunosensor, using potassium ferro-ferricyanide solution as the electrochemical probe. An LDR of 0.70-7.0 and 1.0-30 pmol L-1, with an LOD of 0.70 and 1.0 pmol L-1 were obtained by SWV and EIS, respectively. As a proof of concept, the immunosensor was successfully applied for the detection of the SARS-CoV-2 spike protein in enriched synthetic saliva samples, which demonstrates the potential of using the proposed sensor as an alternative platform for the diagnosis of COVID-19 in the future.
Collapse
Affiliation(s)
- Rodrigo Vieira Blasques
- Laboratory of Sensors, Nanomedicine and Nanostructured Materials, Federal University of São Carlos, Araras 13600-970, Brazil
- Department of Physics, Chemistry, and Mathematics, Federal University of São Carlos, Sorocaba 18052-780, Brazil
| | - Paulo Roberto de Oliveira
- Laboratory of Sensors, Nanomedicine and Nanostructured Materials, Federal University of São Carlos, Araras 13600-970, Brazil
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, UK
| | - Cristiane Kalinke
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, UK
- Institute of Chemistry, University of Campinas, Campinas 13083-970, Brazil
| | - Laís Canniatti Brazaca
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA 02138, USA
| | - Robert D. Crapnell
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, UK
| | | | - Craig E. Banks
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, UK
| | - Bruno Campos Janegitz
- Laboratory of Sensors, Nanomedicine and Nanostructured Materials, Federal University of São Carlos, Araras 13600-970, Brazil
| |
Collapse
|
20
|
Clark K, Schenkel MS, Pittman TW, Samper IC, Anderson LBR, Khamcharoen W, Elmegerhi S, Perera R, Siangproh W, Kennan AJ, Geiss BJ, Dandy DS, Henry CS. Electrochemical Capillary Driven Immunoassay for Detection of SARS-CoV-2. ACS MEASUREMENT SCIENCE AU 2022; 2:584-594. [PMID: 36570470 PMCID: PMC9469961 DOI: 10.1021/acsmeasuresciau.2c00037] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 08/09/2022] [Accepted: 08/16/2022] [Indexed: 05/28/2023]
Abstract
The COVID-19 pandemic focused attention on a pressing need for fast, accurate, and low-cost diagnostic tests. This work presents an electrochemical capillary driven immunoassay (eCaDI) developed to detect SARS-CoV-2 nucleocapsid (N) protein. The low-cost flow device is made of polyethylene terephthalate (PET) and adhesive films. Upon addition of a sample, reagents and washes are sequentially delivered to an integrated screen-printed carbon electrode for detection, thus automating a full sandwich immunoassay with a single end-user step. The modified electrodes are sensitive and selective for SARS-CoV-2 N protein and stable for over 7 weeks. The eCaDI was tested with influenza A and Sindbis virus and proved to be selective. The eCaDI was also successfully applied to detect nine different SARS-CoV-2 variants, including Omicron.
Collapse
Affiliation(s)
- Kaylee
M. Clark
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Melissa S. Schenkel
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Trey W. Pittman
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Isabelle C. Samper
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Department
of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Loran B. R. Anderson
- Department
of Microbiology, Immunology, and Pathology, Colorado State University, Fort
Collins, Colorado 80523, United States
| | - Wisarut Khamcharoen
- Department
of Chemistry, Faculty of Science, Srinakharinwirot
University, Bangkok 10110, Thailand
| | - Suad Elmegerhi
- Department
of Microbiology, Immunology, and Pathology, Colorado State University, Fort
Collins, Colorado 80523, United States
| | - Rushika Perera
- Department
of Microbiology, Immunology, and Pathology, Colorado State University, Fort
Collins, Colorado 80523, United States
| | - Weena Siangproh
- Department
of Chemistry, Faculty of Science, Srinakharinwirot
University, Bangkok 10110, Thailand
| | - Alan J. Kennan
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Brian J. Geiss
- Department
of Microbiology, Immunology, and Pathology, Colorado State University, Fort
Collins, Colorado 80523, United States
- School
of Biomedical Engineering, Colorado State
University, Fort Collins, Colorado 80523, United States
| | - David S. Dandy
- Department
of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
- School
of Biomedical Engineering, Colorado State
University, Fort Collins, Colorado 80523, United States
| | - Charles S. Henry
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Department
of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
- School
of Biomedical Engineering, Colorado State
University, Fort Collins, Colorado 80523, United States
| |
Collapse
|
21
|
Palacios-Corella M, Ghosh K, Redondo E, Pumera M. Polyoxometalate-Enhanced 3D-Printed Supercapacitors. CHEMSUSCHEM 2022; 15:e202201490. [PMID: 36333103 DOI: 10.1002/cssc.202201490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 09/12/2022] [Indexed: 06/16/2023]
Abstract
The contemporary critical energy crisis demands the fast and cost-effective preparation of supercapacitors to replace old-fashioned batteries. 3D-printing has been established as a fast, cheap, and reliable new manufacturing technique that enables the preparation of such devices.. Unfortunately, carbon-based filaments used in 3D printing lack the necessary electrical properties to build supercapacitors by themselves and have to be combined with other materials to reach their full potential. In this study, carbon-based 3D-printed carbon electrodes (3D-PCE) have been combined with two polyoxometalates (that share the same redox cluster) by drop casting of the inorganic cluster mixed with a conducting slurry. The modified electrodes show higher capacitances than reference carbon electrodes showing the exceptional properties of the polyoxometalates. Moreover, the different nature of the polyoxometalate counter ions allows for their distinct deposition, giving rise to a different coverage of the surface of the 3D-PCE. The different coverage and the nature of the interaction of the counter ion with the electrolyte significantly modify the capacitance and resistance of the materials, playing a key role that should not be overlooked during their preparation.
Collapse
Affiliation(s)
- Mario Palacios-Corella
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 123, 61200, Brno, Czech Republic
| | - Kalyan Ghosh
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 123, 61200, Brno, Czech Republic
| | - Edurne Redondo
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 123, 61200, Brno, Czech Republic
| | - Martin Pumera
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 123, 61200, Brno, Czech Republic
- Faculty of Electrical Engineering and Computer Science, VSB - Technical University of Ostrava, 17. listopadu 2172/15, 70800, Ostrava, Czech Republic
- Department of Medical Research, China Medical University Hospital, China Medical University, No. 91 Hsueh-Shih Road, 40402, Taichung, Taiwan
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, 03722, Seoul (Republic of, Korea
| |
Collapse
|
22
|
Crapnell RD, Garcia-Miranda Ferrari A, Whittingham MJ, Sigley E, Hurst NJ, Keefe EM, Banks CE. Adjusting the Connection Length of Additively Manufactured Electrodes Changes the Electrochemical and Electroanalytical Performance. SENSORS (BASEL, SWITZERLAND) 2022; 22:9521. [PMID: 36502222 PMCID: PMC9736051 DOI: 10.3390/s22239521] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 11/25/2022] [Accepted: 12/02/2022] [Indexed: 05/09/2023]
Abstract
Changing the connection length of an additively manufactured electrode (AME) has a significant impact on the electrochemical and electroanalytical response of the system. In the literature, many electrochemical platforms have been produced using additive manufacturing with great variations in how the AME itself is described. It is seen that when measuring the near-ideal outer-sphere redox probe hexaamineruthenium (III) chloride (RuHex), decreasing the AME connection length enhances the heterogeneous electrochemical transfer (HET) rate constant (k0) for the system. At slow scan rates, there is a clear change in the peak-to-peak separation (ΔEp) observed in the RuHex voltammograms, with the ΔEp shifting from 118 ± 5 mV to 291 ± 27 mV for the 10 and 100 mm electrodes, respectively. For the electroanalytical determination of dopamine, no significant difference is noticed at low concentrations between 10- and 100-mm connection length AMEs. However, at concentrations of 1 mM dopamine, the peak oxidation is shifted to significantly higher potentials as the AME connection length is increased, with a shift of 150 mV measured. It is recommended that in future work, all AME dimensions, not just the working electrode head size, is reported along with the resistance measured through electrochemical impedance spectroscopy to allow for appropriate comparisons with other reports in the literature. To produce the best additively manufactured electrochemical systems in the future, researchers should endeavor to use the shortest AME connection lengths that are viable for their designs.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Craig E. Banks
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, UK
| |
Collapse
|
23
|
Siripongpreda T, Hoven VP, Narupai B, Rodthongku N. Emerging 3D printing based on polymers and nanomaterial additives: Enhancement of properties and potential applications. Eur Polym J 2022. [DOI: 10.1016/j.eurpolymj.2022.111806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
24
|
Wan M, Jimu A, Yang H, Zhou J, Dai X, Zheng Y, Ou J, Yang Y, Liu J, Wang L. MXene quantum dots enhanced 3D-printed electrochemical sensor for the highly sensitive detection of dopamine. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
25
|
Braz BA, Hospinal-Santiani M, Martins G, Pinto CS, Zarbin AJG, Beirão BCB, Thomaz-Soccol V, Bergamini MF, Marcolino-Junior LH, Soccol CR. Graphene-Binding Peptide in Fusion with SARS-CoV-2 Antigen for Electrochemical Immunosensor Construction. BIOSENSORS 2022; 12:bios12100885. [PMID: 36291021 PMCID: PMC9599560 DOI: 10.3390/bios12100885] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 10/05/2022] [Accepted: 10/12/2022] [Indexed: 06/02/2023]
Abstract
The development of immunosensors to detect antibodies or antigens has stood out in the face of traditional methods for diagnosing emerging diseases such as the one caused by the SARS-CoV-2 virus. The present study reports the construction of a simplified electrochemical immunosensor using a graphene-binding peptide applied as a recognition site to detect SARS-CoV-2 antibodies. A screen-printed electrode was used for sensor preparation by adding a solution of peptide and reduced graphene oxide (rGO). The peptide-rGO suspension was characterized by scanning electron microscopy (SEM), Raman spectroscopy, and Fourier transform infrared spectroscopy (FT-IR). The electrochemical characterization (electrochemical impedance spectroscopy-EIS, cyclic voltammetry-CV and differential pulse voltammetry-DPV) was performed on the modified electrode. The immunosensor response is based on the decrease in the faradaic signal of an electrochemical probe resulting from immunocomplex formation. Using the best set of experimental conditions, the analytic curve obtained showed a good linear regression (r2 = 0.913) and a limit of detection (LOD) of 0.77 μg mL-1 for antibody detection. The CV and EIS results proved the efficiency of device assembly. The high selectivity of the platform, which can be attributed to the peptide, was demonstrated by the decrease in the current percentage for samples with antibody against the SARS-CoV-2 S protein and the increase in the other antibodies tested. Additionally, the DPV measurements showed a clearly distinguishable response in assays against human serum samples, with sera with a response above 95% being considered negative, whereas responses below this value were considered positive. The diagnostic platform developed with specific peptides is promising and has the potential for application in the diagnosis of other infections that lead to high antibody titers.
Collapse
Affiliation(s)
- Beatriz A. Braz
- Molecular Biology Laboratory, Graduate Program in Bioprocess Engineering and Biotechnology, Federal University of Paraná (UFPR), Curitiba 81531-980, PR, Brazil
- Laboratory of Electrochemical Sensors (LabSensE), Department of Chemistry, Federal University of Paraná (UFPR), Curitiba 81531-980, PR, Brazil
| | - Manuel Hospinal-Santiani
- Molecular Biology Laboratory, Graduate Program in Bioprocess Engineering and Biotechnology, Federal University of Paraná (UFPR), Curitiba 81531-980, PR, Brazil
| | - Gustavo Martins
- Laboratory of Electrochemical Sensors (LabSensE), Department of Chemistry, Federal University of Paraná (UFPR), Curitiba 81531-980, PR, Brazil
| | - Cristian S. Pinto
- Materials Chemistry Group (GQM), Department of Chemistry, Federal University of Paraná (UFPR), Curitiba 81531-980, PR, Brazil
| | - Aldo J. G. Zarbin
- Materials Chemistry Group (GQM), Department of Chemistry, Federal University of Paraná (UFPR), Curitiba 81531-980, PR, Brazil
| | - Breno C. B. Beirão
- Graduate Program in Microbiology, Parasitology, and Pathology, Federal University of Paraná (UFPR), Curitiba 81531-980, PR, Brazil
| | - Vanete Thomaz-Soccol
- Molecular Biology Laboratory, Graduate Program in Bioprocess Engineering and Biotechnology, Federal University of Paraná (UFPR), Curitiba 81531-980, PR, Brazil
| | - Márcio F. Bergamini
- Laboratory of Electrochemical Sensors (LabSensE), Department of Chemistry, Federal University of Paraná (UFPR), Curitiba 81531-980, PR, Brazil
| | - Luiz H. Marcolino-Junior
- Laboratory of Electrochemical Sensors (LabSensE), Department of Chemistry, Federal University of Paraná (UFPR), Curitiba 81531-980, PR, Brazil
| | - Carlos R. Soccol
- Molecular Biology Laboratory, Graduate Program in Bioprocess Engineering and Biotechnology, Federal University of Paraná (UFPR), Curitiba 81531-980, PR, Brazil
| |
Collapse
|
26
|
Ma C, Lu D, Gan H, Yao Z, Zhu DZ, Luo J, Fu Q, Kurup P. The critical experimental aspects for developing pathogen electrochemical biosensors: A lesson during the COVID-19 pandemic. Talanta 2022:124009. [PMCID: PMC9562616 DOI: 10.1016/j.talanta.2022.124009] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Though the bitter global pandemic posed a severe public health threat, it set an unprecedented stage for different research teams to present various technologies for detecting SARS-CoV-2, providing a rare and hard-won lesson for one to comprehensively survey the core experimental aspects in developing pathogens electrochemical biosensors. Apart from collecting all the published biosensor studies, we focused on the effects and consequences of using different receptors, such as antibodies, aptamers, ACE 2, and MIPs, which are one of the core topics of developing a pathogen biosensor. In addition, we tried to find an appropriate and distinctive application scenario (e.g., wastewater-based epidemiology) to maximize the advantages of using electrochemical biosensors to detect pathogens. Based on the enormous amount of information from those published studies, features that fit and favor wastewater pathogen detection can be picked up and integrated into a specific strategy to perform quantitative measurements in wastewater samples.
Collapse
Affiliation(s)
- Chen Ma
- Department of Civil and Environmental Engineering, Ningbo University, Zhejiang, China
| | - Dingnan Lu
- Department of Civil and Environmental Engineering, Ningbo University, Zhejiang, China,Department of Civil and Environmental Engineering, University of Massachusetts Lowell, One University Ave., Lowell, MA, 01854, USA,Corresponding author. Department of Civil and Environmental Engineering, Ningbo University, Zhejiang, China
| | - Huihui Gan
- Department of Civil and Environmental Engineering, Ningbo University, Zhejiang, China
| | - Zhiyuan Yao
- Department of Civil and Environmental Engineering, Ningbo University, Zhejiang, China
| | - David Z. Zhu
- Department of Civil and Environmental Engineering, Ningbo University, Zhejiang, China,Department of Civil and Environmental Engineering, University of Alberta, Edmonton, AB, T6G 1H9, Canada
| | - Jiayue Luo
- Department of Civil and Environmental Engineering, Ningbo University, Zhejiang, China,Department of Civil and Environmental Engineering, University of Massachusetts Lowell, One University Ave., Lowell, MA, 01854, USA
| | - Qiang Fu
- Department of Biomedical Engineering and Biotechnology, University of Massachusetts Lowell, One University Ave., Lowell, MA, 01854, USA
| | - Pradeep Kurup
- Department of Civil and Environmental Engineering, University of Massachusetts Lowell, One University Ave., Lowell, MA, 01854, USA,Corresponding author
| |
Collapse
|
27
|
Farzin MA, Abdoos H, Saber R. AuNP-based biosensors for the diagnosis of pathogenic human coronaviruses: COVID-19 pandemic developments. Anal Bioanal Chem 2022; 414:7069-7084. [PMID: 35781591 PMCID: PMC9251037 DOI: 10.1007/s00216-022-04193-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 06/17/2022] [Accepted: 06/21/2022] [Indexed: 12/15/2022]
Abstract
The outbreak rate of human coronaviruses (CoVs) especially highly pathogenic CoVs is increasing alarmingly. Early detection of these viruses allows treatment interventions to be provided more quickly to people at higher risk, as well as helping to identify asymptomatic carriers and isolate them as quickly as possible, thus preventing the disease transmission chain. The current diagnostic methods such as RT-PCR are not ideal due to high cost, low accuracy, low speed, and probability of false results. Therefore, a reliable and accurate method for the detection of CoVs in biofluids can become a front-line tool in order to deal with the spread of these deadly viruses. Currently, the nanomaterial-based sensing devices for detection of human coronaviruses from laboratory diagnosis to point-of-care (PoC) diagnosis are progressing rapidly. Gold nanoparticles (AuNPs) have revolutionized the field of biosensors because of the outstanding optical and electrochemical properties. In this review paper, a detailed overview of AuNP-based biosensing strategies with the varied transducers (electrochemical, optical, etc.) and also different biomarkers (protein antigens and nucleic acids) was presented for the detection of human coronaviruses including SARS-CoV-2, SARS-CoV-1, and MERS-CoV and lowly pathogenic CoVs. The present review highlights the newest trends in the SARS-CoV-2 nanobiosensors from the beginning of the COVID-19 epidemic until 2022. We hope that the presented examples in this review paper convince readers that AuNPs are a suitable platform for the designing of biosensors.
Collapse
Affiliation(s)
- Mohammad Ali Farzin
- Department of Nanotechnology, Faculty of New Sciences and Technologies, Semnan University, P. O. Box: 35131-19111, Semnan, Iran
| | - Hassan Abdoos
- Department of Nanotechnology, Faculty of New Sciences and Technologies, Semnan University, P. O. Box: 35131-19111, Semnan, Iran.
| | - Reza Saber
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
28
|
Mao S, Fu L, Yin C, Liu X, Karimi-Maleh H. The role of electrochemical biosensors in SARS-CoV-2 detection: a bibliometrics-based analysis and review. RSC Adv 2022; 12:22592-22607. [PMID: 36105989 PMCID: PMC9372877 DOI: 10.1039/d2ra04162f] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 08/03/2022] [Indexed: 12/16/2022] Open
Abstract
The global pandemic of COVID-19, which began in late 2019, has resulted in extremely high morbidity and severe mortality worldwide, with important implications for human health, international trade, and national politics. Severe acute respiratory syndrome coronavirus (SARS-CoV-2) is the primary pathogen causing COVID-19. Analytical chemistry played an important role in this global epidemic event, and detection of SARS-CoV-2 even became a part of daily life. Analytical chemists have devoted much effort and enthusiasm to this event, and different analytical techniques have shown very rapid development. Electrochemical biosensors are highly efficient, sensitive, and cost-effective and have been used to detect many highly pathogenic viruses long before this event. However, another fact is that electrochemical biosensors are not the technology of choice for most detection applications. This review describes for the first time the role played by electrochemical biosensors in SARS-CoV-2 detection from a bibliometric perspective. This paper analyzed 254 relevant research papers up to June 2022. The contributions of different countries and institutions to this topic were analyzed. Keyword analysis was used to explore different methodological attempts of electrochemical detection techniques. More importantly, we are trying to find an answer to the question: do electrochemical biosensors have the potential to become a genuinely employable detection technology in an outbreak of infectious disease?
Collapse
Affiliation(s)
- Shudan Mao
- Key Laboratory of Pollution Exposure and Health Intervention of Zhejiang Province, Interdisciplinary Research Academy, Zhejiang Shuren University Hangzhou 310021 PR China
| | - Li Fu
- Key Laboratory of Novel Materials for Sensor of Zhejiang Province, College of Materials and Environmental Engineering, Hangzhou Dianzi University Hangzhou 310018 China
| | - Chengliang Yin
- National Engineering Laboratory for Medical Big Data Application Technology, Chinese PLA General Hospital Beijing China
- Medical Big Data Research Center, Medical Innovation Research Division of PLA General Hospital Beijing China
| | - Xiaozhu Liu
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University Chongqing 400010 China
| | - Hassan Karimi-Maleh
- School of Resources and Environment, University of Electronic Science and Technology of China Xiyuan Ave 611731 Chengdu China
- Department of Chemical Engineering, Quchan University of Technology Quchan 9477177870 Iran
- Department of Chemical Sciences, University of Johannesburg Doornfontein Campus, 2028 Johannesburg 17011 South Africa
| |
Collapse
|
29
|
Silva LRG, Stefano JS, Orzari LO, Brazaca LC, Carrilho E, Marcolino-Junior LH, Bergamini MF, Munoz RAA, Janegitz BC. Electrochemical Biosensor for SARS-CoV-2 cDNA Detection Using AuPs-Modified 3D-Printed Graphene Electrodes. BIOSENSORS 2022; 12:622. [PMID: 36005018 PMCID: PMC9405530 DOI: 10.3390/bios12080622] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 08/05/2022] [Accepted: 08/06/2022] [Indexed: 11/16/2022]
Abstract
A low-cost and disposable graphene polylactic (G-PLA) 3D-printed electrode modified with gold particles (AuPs) was explored to detect the cDNA of SARS-CoV-2 and creatinine, a potential biomarker for COVID-19. For that, a simple, non-enzymatic electrochemical sensor, based on a Au-modified G-PLA platform was applied. The AuPs deposited on the electrode were involved in a complexation reaction with creatinine, resulting in a decrease in the analytical response, and thus providing a fast and simple electroanalytical device. Physicochemical characterizations were performed by SEM, EIS, FTIR, and cyclic voltammetry. Square wave voltammetry was employed for the creatinine detection, and the sensor presented a linear response with a detection limit of 0.016 mmol L-1. Finally, a biosensor for the detection of SARS-CoV-2 was developed based on the immobilization of a capture sequence of the viral cDNA upon the Au-modified 3D-printed electrode. The concentration, immobilization time, and hybridization time were evaluated in presence of the DNA target, resulting in a biosensor with rapid and low-cost analysis, capable of sensing the cDNA of the virus with a good limit of detection (0.30 µmol L-1), and high sensitivity (0.583 µA µmol-1 L). Reproducible results were obtained (RSD = 1.14%, n = 3), attesting to the potentiality of 3D-printed platforms for the production of biosensors.
Collapse
Affiliation(s)
- Luiz R. G. Silva
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, Araras 13600-970, SP, Brazil
- Department of Physics, Chemistry and Mathematics, Federal University of São Carlos, Sorocaba 18052-780, SP, Brazil
| | - Jéssica S. Stefano
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, Araras 13600-970, SP, Brazil
| | - Luiz O. Orzari
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, Araras 13600-970, SP, Brazil
- Department of Physics, Chemistry and Mathematics, Federal University of São Carlos, Sorocaba 18052-780, SP, Brazil
| | - Laís C. Brazaca
- São Carlos Institute of Chemistry (IQSC), University of São Paulo (USP), São Carlos 13566-590, SP, Brazil
- National Institute of Science and Technology in Bioanalysis-INCTBio, Campinas 13083-970, SP, Brazil
| | - Emanuel Carrilho
- São Carlos Institute of Chemistry (IQSC), University of São Paulo (USP), São Carlos 13566-590, SP, Brazil
- National Institute of Science and Technology in Bioanalysis-INCTBio, Campinas 13083-970, SP, Brazil
| | - Luiz H. Marcolino-Junior
- Chemistry Department, Laboratory of Electrochemical Sensors (LabSensE), Federal University of Paraná, Curitiba 81531-980, PR, Brazil
| | - Marcio F. Bergamini
- Chemistry Department, Laboratory of Electrochemical Sensors (LabSensE), Federal University of Paraná, Curitiba 81531-980, PR, Brazil
| | - Rodrigo A. A. Munoz
- National Institute of Science and Technology in Bioanalysis-INCTBio, Campinas 13083-970, SP, Brazil
- Institute of Chemistry, Federal University of Uberlândia, Uberlândia 38400-902, MG, Brazil
| | - Bruno C. Janegitz
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, Araras 13600-970, SP, Brazil
| |
Collapse
|
30
|
Cajigas S, Alzate D, Fernández M, Muskus C, Orozco J. Electrochemical genosensor for the specific detection of SARS-CoV-2. Talanta 2022; 245:123482. [PMID: 35462140 PMCID: PMC9012668 DOI: 10.1016/j.talanta.2022.123482] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 04/08/2022] [Accepted: 04/13/2022] [Indexed: 12/19/2022]
Abstract
Infection caused by Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) is responsible for the Coronavirus disease (COVID-19) and the current pandemic. Its mortality rate increases, demonstrating the imperative need for acute and rapid diagnostic tools as an alternative to current serological tests and molecular techniques. Features of electrochemical genosensor devices make them amenable for fast and accurate testing closer to the patient. This work reports on a specific electrochemical genosensor for SARS-CoV-2 detection and discrimination against homologous respiratory viruses. The electrochemical biosensor was assembled by immobilizing thiolated capture probes on top of maleimide-coated magnetic particles, followed by specific target hybridization between the capture and biotinylated signaling probes in a sandwich-type manner. The probes were rigorously designed bioinformatically and tested in vitro. Enzymatic complexes based on streptavidin-horseradish peroxidase linked the biotinylated signaling probe to render the biosensor electrochemical response. The genosensor showed to reach a sensitivity of 174.4 μA fM−1 and a limit of detection of 807 fM when using streptavidin poly-HRP20 enzymatic complex, detected SARS-CoV-2 specifically and discriminated it against homologous viruses in spiked samples and samples from SARS-CoV-2 cell cultures, a step forward to detect SARS-CoV-2 closer to the patient as a promising way for diagnosis and surveillance of COVID-19.
Collapse
Affiliation(s)
- Sebastian Cajigas
- Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciencies, University of Antioquia, Complejo Ruta N, Calle 67 N° 52-20, Medellín, 050010, Colombia
| | - Daniel Alzate
- Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciencies, University of Antioquia, Complejo Ruta N, Calle 67 N° 52-20, Medellín, 050010, Colombia
| | - Maritza Fernández
- Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciencies, University of Antioquia, Complejo Ruta N, Calle 67 N° 52-20, Medellín, 050010, Colombia
| | - Carlos Muskus
- Programa de Estudio y Control de Enfermedades Tropicales (PECET), Facultad de Medicina, Universidad de Antioquia, Calle 62 N° 52-59, Medellín, Colombia
| | - Jahir Orozco
- Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciencies, University of Antioquia, Complejo Ruta N, Calle 67 N° 52-20, Medellín, 050010, Colombia.
| |
Collapse
|
31
|
Dettlaff A, Rycewicz M, Ficek M, Wieloszyńska A, Szala M, Ryl J, Bogdanowicz R. Conductive printable electrodes tuned by boron-doped nanodiamond foil additives for nitroexplosive detection. Mikrochim Acta 2022; 189:270. [PMID: 35789434 PMCID: PMC9255478 DOI: 10.1007/s00604-022-05371-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 06/05/2022] [Indexed: 11/28/2022]
Abstract
An efficient additive manufacturing-based composite material fabrication for electrochemical applications is reported. The composite is composed of commercially available graphene-doped polylactide acid (G-PLA) 3D printouts and surface-functionalized with nanocrystalline boron-doped diamond foil (NDF) additives. The NDFs were synthesized on a tantalum substrate and transferred to the 3D-printout surface at 200 °C. No other electrode activation treatment was necessary. Different configurations of low- and heavy-boron doping NDFs were evaluated. The electrode kinetics was analyzed using electrochemical procedures: cyclic voltammetry and electrochemical impedance spectroscopy. The quasi-reversible electrochemical process was reported in each studied case. The studies allowed confirmation of the CV peak-to-peak separation of 63 mV and remarkably high heterogeneous electron transfer rate constant reaching 6.1 × 10−2 cm s−1 for 10 k ppm [B]/[C] thin NDF fitted topside at the G-PLA electrode. Differential pulse voltammetry was used for effective 2,4,6-trinitrotoluene (TNT) detection at the studied electrodes with a 87 ppb limit of detection, and wide linearity range between peak current density and the analyte concentration (0.064 to 64 ppm of TNT). The reported electrode kinetic differences originate primarily from the boron-dopant concentration in the diamond and the various contents of the non-diamond carbon phase.
Collapse
Affiliation(s)
- Anna Dettlaff
- Faculty of Chemistry, Department of Energy Conversion and Storage, Gdańsk University of Technology, 11/12 Narutowicza St, 80-233, Gdańsk, Poland. .,Faculty of Electronics, Telecommunications and Informatics, Department of Metrology and Optoelectronics, Gdańsk University of Technology, 11/12 Narutowicza St, 80-233, Gdańsk, Poland.
| | - Michał Rycewicz
- Faculty of Electronics, Telecommunications and Informatics, Department of Metrology and Optoelectronics, Gdańsk University of Technology, 11/12 Narutowicza St, 80-233, Gdańsk, Poland
| | - Mateusz Ficek
- Faculty of Electronics, Telecommunications and Informatics, Department of Metrology and Optoelectronics, Gdańsk University of Technology, 11/12 Narutowicza St, 80-233, Gdańsk, Poland
| | - Aleksandra Wieloszyńska
- Faculty of Electronics, Telecommunications and Informatics, Department of Metrology and Optoelectronics, Gdańsk University of Technology, 11/12 Narutowicza St, 80-233, Gdańsk, Poland
| | - Mateusz Szala
- Military University of Technology, S. Kaliskiego 2, 00-908, Warsaw, Poland
| | - Jacek Ryl
- Institute of Nanotechnology and Materials Engineering and Advanced Materials Center, Gdańsk University of Technology, 11/12 Narutowicza St, 80-233, Gdańsk, Poland
| | - Robert Bogdanowicz
- Faculty of Electronics, Telecommunications and Informatics, Department of Metrology and Optoelectronics, Gdańsk University of Technology, 11/12 Narutowicza St, 80-233, Gdańsk, Poland
| |
Collapse
|
32
|
Hamidi-Asl E, Heidari-Khoshkelat L, Bakhsh Raoof J, Richard TP, Farhad S, Ghani M. A review on the recent achievements on coronaviruses recognition using electrochemical detection methods. Microchem J 2022; 178:107322. [PMID: 35233118 PMCID: PMC8875855 DOI: 10.1016/j.microc.2022.107322] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 02/21/2022] [Accepted: 02/22/2022] [Indexed: 12/14/2022]
Abstract
Various coronaviruses, which cause a wide range of human and animal diseases, have emerged in the past 50 years. This may be due to their abilities to recombine, mutate, and infect multiple species and cell types. A novel coronavirus, which is a family of severe acute respiratory syndrome (SARS) and Middle East respiratory syndrome (MERS), has been termed COVID-19 by the World Health Organization (WHO). COVID-19 is the strain that has not been previously identified in humans. The early identification and diagnosis of the virus is crucial for effective pandemic prevention. In this study, we review shortly various diagnostic methods for virus assay and focus on recent advances in electrochemical biosensors for COVID-19 detection.
Collapse
Affiliation(s)
- Ezat Hamidi-Asl
- Advanced Energy & Manufacturing Lab, Department of Mechanical Engineering, University of Akron, Akron, OH 44325, USA
| | - Leyla Heidari-Khoshkelat
- Eletroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| | - Jahan Bakhsh Raoof
- Eletroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| | - Tara P Richard
- Department of Biological Science, Southeastern Louisiana University, Hammond, LA 70402, USA
| | - Siamak Farhad
- Advanced Energy & Manufacturing Lab, Department of Mechanical Engineering, University of Akron, Akron, OH 44325, USA
| | - Milad Ghani
- Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| |
Collapse
|
33
|
Pola CC, Rangnekar SV, Sheets R, Szydlowska BM, Downing JR, Parate KW, Wallace SG, Tsai D, Hersam MC, Gomes CL, Claussen JC. Aerosol-jet-printed graphene electrochemical immunosensors for rapid and label-free detection of SARS-CoV-2 in saliva. 2D MATERIALS 2022; 9:035016. [PMID: 35785019 PMCID: PMC9245948 DOI: 10.1088/2053-1583/ac7339] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Rapid, inexpensive, and easy-to-use coronavirus disease 2019 (COVID-19) home tests are key tools in addition to vaccines in the world-wide fight to eliminate national and local shutdowns. However, currently available tests for SARS-CoV-2, the virus that causes COVID-19, are too expensive, painful, and irritating, or not sufficiently sensitive for routine, accurate home testing. Herein, we employ custom-formulated graphene inks and aerosol jet printing (AJP) to create a rapid electrochemical immunosensor for direct detection of SARS-CoV-2 Spike Receptor-Binding Domain (RBD) in saliva samples acquired non-invasively. This sensor demonstrated limits of detection that are considerably lower than most commercial SARS-CoV-2 antigen tests (22.91 ± 4.72 pg/mL for Spike RBD and 110.38 ± 9.00 pg/mL for Spike S1) as well as fast response time (~30 mins), which was facilitated by the functionalization of printed graphene electrodes in a single-step with SARS-CoV-2 polyclonal antibody through the carbodiimide reaction without the need for nanoparticle functionalization or secondary antibody or metallic nanoparticle labels. This immunosensor presents a wide linear sensing range from 1 to 1000 ng/mL and does not react with other coexisting influenza viruses such as H1N1 hemagglutinin. By combining high-yield graphene ink synthesis, automated printing, high antigen selectivity, and rapid testing capability, this work offers a promising alternative to current SARS-CoV-2 antigen tests.
Collapse
Affiliation(s)
- Cícero C. Pola
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA
| | - Sonal V. Rangnekar
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Robert Sheets
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA
| | - Beata M. Szydlowska
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Julia R. Downing
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Kshama W. Parate
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA
| | - Shay G. Wallace
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Daphne Tsai
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Mark C. Hersam
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208, USA
- Department of Chemistry, Northwestern University, Evanston, IL 60208, USA
- Department of Electrical and Computer Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Carmen L. Gomes
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA
| | - Jonathan C. Claussen
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA
| |
Collapse
|
34
|
Vásquez V, Navas MC, Jaimes JA, Orozco J. SARS-CoV-2 electrochemical immunosensor based on the spike-ACE2 complex. Anal Chim Acta 2022; 1205:339718. [PMID: 35414393 PMCID: PMC8941303 DOI: 10.1016/j.aca.2022.339718] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Revised: 02/22/2022] [Accepted: 03/09/2022] [Indexed: 02/06/2023]
Abstract
Rapid, straightforward, and massive diagnosis of coronavirus disease 2019 (COVID-19) is one of the more important measures to mitigate the current pandemics. This work reports on an immunosensor to rapidly detect the spike protein from the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The immunosensing device entraps the spike protein linked to angiotensin-converting enzyme host receptor (ACE2) protein in a sandwich between carboxylated magnetic beads functionalized with an anti-spike antibody and an anti-ACE2 antibody, further labeled with streptavidin (poly)horseradish peroxidase (HRP) reporter enzyme. The particles were confined at the surface of screen-printed gold electrodes, whose signal resulting from the interaction of the enzyme with a mediator was recorded in a portable potentiostat. The immunosensor showed a sensitivity of 0.83 μA∗mL/μg and a limit of detection of 22.5 ng/mL of spike protein, with high reproducibility. As a proof-of-concept, it detected commercial spike protein-supplemented buffer solutions, pseudovirions, isolated viral particles and ten nasopharyngeal swab samples from infected patients compared to samples from three healthy individuals paving the way to detect the virus closer to the patient.
Collapse
|
35
|
Soto D, Orozco J. Peptide-based simple detection of SARS-CoV-2 with electrochemical readout. Anal Chim Acta 2022; 1205:339739. [PMID: 35414399 PMCID: PMC8935448 DOI: 10.1016/j.aca.2022.339739] [Citation(s) in RCA: 31] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 02/15/2022] [Accepted: 03/16/2022] [Indexed: 12/13/2022]
Abstract
Coronavirus disease 2019 (COVID-19) caused by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is considered one of the worst pandemic outbreaks worldwide. This ongoing pandemic urgently requires rapid, accurate, and specific testing devices to detect the virus. We report a simple electrochemical biosensor based on a highly specific synthetic peptide to detect SARS-CoV-2 Spike protein. Unlike other reported electrochemical biosensors involving nanomaterials or complex approaches, our electrochemical platform uses screen-printed gold electrodes functionalized with the thiolated peptide, whose interaction with the Spike protein is directly followed by Electrochemical Impedance Spectroscopy. The electrochemical platform was Spike protein concentration-dependent, with high sensitivity and reproducibility and a limit of detection of 18.2 ng/mL when tested in Spike protein commercial solutions and 0.01 copies/mL in lysed SARS-CoV-2 particles. The label-free biosensor successfully detected the Spike protein in samples from infected patients straightforwardly in only 15 min. The simplicity of the proposed format combined with an on-demand designed peptide opens the path for detecting other pathogen-related antigens.
Collapse
|
36
|
Wu CC, Chiang YH, Chiang HY. A Label-Free Electrochemical Impedimetric Immunosensor with Biotinylated-Antibody for SARS-CoV-2 Nucleoprotein Detection in Saliva. BIOSENSORS 2022; 12:bios12050265. [PMID: 35624566 PMCID: PMC9138907 DOI: 10.3390/bios12050265] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 04/16/2022] [Accepted: 04/20/2022] [Indexed: 05/05/2023]
Abstract
The timely detecting of SARS-CoV-2 coronavirus antigens for infection validation is an urgent request for COVID-19 pandemic control. This study constructed label-free electrochemical impedance spectroscopy (EIS)-based immunosensors based on gold nanostructured screen-printed carbon electrodes (AuNS/SPCEs) to detect the SARS-CoV-2 nucleocapsid protein (N-protein) in saliva. Using short-chain 3-mercaptopropionic acid (MPA) as a linker to covalently bond streptavidin (SA) and bovine serum albumin (BSA) for controlling the oriented immobilization of the biotinylated anti-N-protein antibody (BioAb) can offer a greater sensitivity, a lower limit of detection (LOD), and better reproducibility of immunosensors (defined as BioAb/SA-BSA/MPA/AuNS/SPCEs) than the antibody randomly immobilized immunosensors and the long-chain 11-mercaptoundecanoic acid (MUA)-modified immunosensors (BioAb/SA-BSA/MUA/AuNS/SPCEs). The BioAb/SA-BSA/MPA/AuNS/SPCE-based immunosensors presented good linearity from 0.01 ng/mL to 100 ng/mL and a low LOD of 6 pg/mL in a phosphate buffer solution (PBS) and PBS-diluted saliva. Moreover, the immunosensor exhibited little cross-activity with other viral antigens such as MERS-CoV N-protein, influenza A N-protein, influenza B N-protein, and SARS-CoV-2 spike protein, indicating the high specificity of the immunosensors. The disposable label-free EIS-based immunosensors have promising potential in facilitating the rapid and sensitive tests of saliva-based COVID-19 diagnostics.
Collapse
Affiliation(s)
- Ching-Chou Wu
- Department of Bio-industrial Mechatronics Engineering, National Chung Hsing University, Taichung 402, Taiwan;
- Innovation and Development Center of Sustainable Agriculture, National Chung Hsing University, Taichung 402, Taiwan
- Correspondence: ; Tel.: +886-4-2285-1268
| | - Yu-Huan Chiang
- Department of Bio-industrial Mechatronics Engineering, National Chung Hsing University, Taichung 402, Taiwan;
| | | |
Collapse
|
37
|
Madhurantakam S, Muthukumar S, Prasad S. Emerging Electrochemical Biosensing Trends for Rapid Diagnosis of COVID-19 Biomarkers as Point-of-Care Platforms: A Critical Review. ACS OMEGA 2022; 7:12467-12473. [PMID: 35474766 PMCID: PMC9026073 DOI: 10.1021/acsomega.2c00638] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 03/28/2022] [Indexed: 05/15/2023]
Abstract
Rapid diagnosis is a critical aspect associated with controlling the spread of COVID-19. Electrochemical sensor platforms are ideally suited for rapid and highly sensitive detection of biomolecules. This review focuses on state-of-the-art of COVID-19 biomarker detection by utilizing electrochemical biosensing platforms. Point-of-care (POC) sensing is one of the most promising and emerging fields in detecting and quantifying health biomarkers. Electrochemical biosensors play a major role in the development of point-of-care devices because of their high sensitivity, specificity, and ability for rapid analysis. Integration of electrochemistry with point-of-care technologies in the context of COVID-19 diagnosis and screening has facilitated in convenient operation, miniaturization, and portability. Identification of potential biomarkers in disease diagnosis is crucial for patient monitoring concerning severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In this review, we will discuss the choice of biomarkers in addition to the various types of electrochemical sensors that have been developed to meet the needs of rapid detection and disease severity analysis.
Collapse
Affiliation(s)
- Sasya Madhurantakam
- Department
of Bioengineering, The University of Texas
at Dallas, Richardson, Texas 75080, United States
| | | | - Shalini Prasad
- Department
of Bioengineering, The University of Texas
at Dallas, Richardson, Texas 75080, United States
- E-mail:
| |
Collapse
|
38
|
Liu N, Liu R, Zhang J. CRISPR-Cas12a-mediated label-free electrochemical aptamer-based sensor for SARS-CoV-2 antigen detection. Bioelectrochemistry 2022; 146:108105. [PMID: 35367933 PMCID: PMC8934182 DOI: 10.1016/j.bioelechem.2022.108105] [Citation(s) in RCA: 32] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 03/15/2022] [Accepted: 03/18/2022] [Indexed: 12/24/2022]
Abstract
Serological antigen testing has emerged as an important diagnostic paradigm in COVID-19, but often suffers from potential cross-reactivity. To address this limitation, we herein report a label-free electrochemical aptamer-based sensor for the detection of SARS-CoV-2 antigen by integrating aptamer-based specific recognition with CRISPR-Cas12a-mediated signal amplification. The sensing principle is based on the competitive binding of antigen and the preassembled Cas12a-crRNA complex to the antigen-specific aptamer, resulting in a change in the collateral cleavage activity of Cas12a. To further generate an electrochemical signal, a DNA architecture was fabricated by in situ rolling circle amplification on a gold electrode, which serves as a novel substrate for Cas12a. Upon Cas12a-based collateral DNA cleavage, the DNA architecture was degraded, leading to a significant decrease in impedance that can be measured spectroscopically. Using SARS-CoV-2 nucleocapsid antigen as the model, the proposed CRISPR-Cas12a-based electrochemical sensor (CRISPR-E) showed excellent analytical performance for the quantitative detection of nucleocapsid antigen. Since in vitro selection can obtain aptamers selective for many SARS-CoV-2 antigens, the proposed strategy can expand this powerful CRISPR-E system significantly for quantitative monitoring of a wide range of COVID-19 biomarkers.
Collapse
Affiliation(s)
- Na Liu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
| | - Ran Liu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
| | - Jingjing Zhang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China; Chemistry and Biomedicine Innovation Center (ChemBIC), Nanjing University, Nanjing 210023, China.
| |
Collapse
|
39
|
Stefano JS, Guterres E Silva LR, Rocha RG, Brazaca LC, Richter EM, Abarza Muñoz RA, Janegitz BC. New conductive filament ready-to-use for 3D-printing electrochemical (bio)sensors: Towards the detection of SARS-CoV-2. Anal Chim Acta 2022; 1191:339372. [PMID: 35033268 PMCID: PMC9381826 DOI: 10.1016/j.aca.2021.339372] [Citation(s) in RCA: 34] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Revised: 11/30/2021] [Accepted: 12/09/2021] [Indexed: 12/15/2022]
Abstract
The 3D printing technology has gained ground due to its wide range of applicability. The development of new conductive filaments contributes significantly to the production of improved electrochemical devices. In this context, we report a simple method to producing an efficient conductive filament, containing graphite within the polymer matrix of PLA, and applied in conjunction with 3D printing technology to generate (bio)sensors without the need for surface activation. The proposed method for producing the conductive filament consists of four steps: (i) mixing graphite and PLA in a heated reflux system; (ii) recrystallization of the composite; (iii) drying and; (iv) extrusion. The produced filament was used for the manufacture of electrochemical 3D printed sensors. The filament and sensor were characterized by physicochemical techniques, such as SEM, TGA, Raman, FTIR as well as electrochemical techniques (EIS and CV). Finally, as a proof-of-concept, the fabricated 3D-printed sensor was applied for the determination of uric acid and dopamine in synthetic urine and used as a platform for the development of a biosensor for the detection of SARS-CoV-2. The developed sensors, without pre-treatment, provided linear ranges of 0.5-150.0 and 5.0-50.0 μmol L-1, with low LOD values (0.07 and 0.11 μmol L-1), for uric acid and dopamine, respectively. The developed biosensor successfully detected SARS-CoV-2 S protein, with a linear range from 5.0 to 75.0 nmol L-1 (0.38 μg mL-1 to 5.74 μg mL-1) and LOD of 1.36 nmol L-1 (0.10 μg mL-1) and sensitivity of 0.17 μA nmol-1 L (0.01 μA μg-1 mL). Therefore, the lab-made produced and the ready-to-use conductive filament is promising and can become an alternative route for the production of different 3D electrochemical (bio)sensors and other types of conductive devices by 3D printing.
Collapse
Affiliation(s)
- Jéssica Santos Stefano
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, 13600-970, Araras, São Paulo, Brazil.
| | - Luiz Ricardo Guterres E Silva
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, 13600-970, Araras, São Paulo, Brazil
| | - Raquel Gomes Rocha
- Institute of Chemistry, Federal University of Uberlândia, 38400-902, Uberlândia, Minas Gerais, Brazil
| | - Laís Canniatti Brazaca
- Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo, 13560-970, São Carlos, São Paulo, Brazil; National Institute of Science and Technology in Bioanalysis-INCTBio, 13083-970, Campinas, São Paulo, Brazil
| | - Eduardo Mathias Richter
- Institute of Chemistry, Federal University of Uberlândia, 38400-902, Uberlândia, Minas Gerais, Brazil; National Institute of Science and Technology in Bioanalysis-INCTBio, 13083-970, Campinas, São Paulo, Brazil
| | - Rodrigo Alejandro Abarza Muñoz
- Institute of Chemistry, Federal University of Uberlândia, 38400-902, Uberlândia, Minas Gerais, Brazil; National Institute of Science and Technology in Bioanalysis-INCTBio, 13083-970, Campinas, São Paulo, Brazil.
| | - Bruno Campos Janegitz
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, 13600-970, Araras, São Paulo, Brazil.
| |
Collapse
|
40
|
Garcia-Miranda Ferrari A, Hurst NJ, Bernalte E, Crapnell RD, Whittingham MJ, Brownson DAC, Banks CE. Exploration of defined 2-dimensional working electrode shapes through additive manufacturing. Analyst 2022; 147:5121-5129. [DOI: 10.1039/d2an01412b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
In this work, the electrochemical response of different morphologies (shapes) and dimensions of additively manufactured (3D-printing) carbon black(CB)/poly-lactic acid (PLA) electrodes are reported.
Collapse
Affiliation(s)
| | - Nicholas J. Hurst
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, M1 5GD, UK
| | - Elena Bernalte
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, M1 5GD, UK
| | - Robert D. Crapnell
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, M1 5GD, UK
| | - Matthew J. Whittingham
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, M1 5GD, UK
| | - Dale A. C. Brownson
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, M1 5GD, UK
| | - Craig E. Banks
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, M1 5GD, UK
| |
Collapse
|
41
|
Han P, Liu C, Staples R, Moran CS, Ramachandra SS, Gómez-Cerezo MN, Ivanovski S. Salivary SARS-CoV-2 antibody detection using S1-RBD protein-immobilized 3D melt electrowritten poly(ε-caprolactone) scaffolds. RSC Adv 2022; 12:24849-24856. [PMID: 36128389 PMCID: PMC9429024 DOI: 10.1039/d2ra03979f] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 08/24/2022] [Indexed: 11/21/2022] Open
Abstract
Sensitive detection of immunoglobulin antibodies against SARS-CoV-2 during the COVID-19 pandemic is critical to monitor the adaptive immune response after BNT162b2 mRNA vaccination. Currently employed binding antibody detection tests using 2D microplate-based enzyme-linked immunosorbent assays (ELISA) are limited by the degree of sensitivity. In this study, a 3D antibody test was developed by immobilizing the receptor-binding domain on Spike subunit 1 (S1-RBD) of SARS-CoV-2 onto engineered melt electrowritten (MEW) poly(ε-caprolactone) (PCL) scaffolds (pore: 500 μm, fiber diameter: 17 μm) using carbodiimide crosslinker chemistry. Protein immobilization was confirmed using X-ray photoelectron spectroscopy (XPS) by the presence of peaks corresponding with nitrogen. Self-developed indirect ELISA was performed to assess the functionality of the 3D platform in comparison with a standard 2D tissue culture plate (TCP) system, using whole unstimulated saliva samples from 14 non-vaccinated and 20 vaccinated participants (1- and 3- weeks post-dose 1; 3 days, 1 week and 3 weeks post-dose 2) without prior SARS-CoV-2 infection. The three-dimensional S1-RBD PCL scaffolds, while demonstrating a kinetic trend comparable to 2D TCP, exhibited significantly higher sensitivity and detection levels for all three immunoglobulins assayed (IgG, IgM, and IgA). These novel findings highlight the potential of MEW PCL constructs in the development of improved low-cost, point-of-care, and self-assessing diagnostic platforms for the detection and monitoring of SARS-CoV-2 antibodies. Our work developed a 3D SARS-CoV-2 antibody detection platform in non-invasive saliva samples using S1-RBD protein-immobilized 3D melt electrowritten poly(ε-caprolactone) scaffolds.![]()
Collapse
Affiliation(s)
- Pingping Han
- The University of Queensland, School of Dentistry, Brisbane, QLD 4006, Australia
- The University of Queensland, School of Dentistry, Center for Oral-facial Regeneration, Rehabilitation and Reconstruction (COR3), Brisbane, QLD 4006, Australia
| | - Chun Liu
- The University of Queensland, School of Dentistry, Brisbane, QLD 4006, Australia
- The University of Queensland, School of Dentistry, Center for Oral-facial Regeneration, Rehabilitation and Reconstruction (COR3), Brisbane, QLD 4006, Australia
| | - Reuben Staples
- The University of Queensland, School of Dentistry, Brisbane, QLD 4006, Australia
- The University of Queensland, School of Dentistry, Center for Oral-facial Regeneration, Rehabilitation and Reconstruction (COR3), Brisbane, QLD 4006, Australia
| | - Corey S. Moran
- The University of Queensland, School of Dentistry, Brisbane, QLD 4006, Australia
- The University of Queensland, School of Dentistry, Center for Oral-facial Regeneration, Rehabilitation and Reconstruction (COR3), Brisbane, QLD 4006, Australia
| | - Srinivas Sulugodu Ramachandra
- The University of Queensland, School of Dentistry, Brisbane, QLD 4006, Australia
- The University of Queensland, School of Dentistry, Center for Oral-facial Regeneration, Rehabilitation and Reconstruction (COR3), Brisbane, QLD 4006, Australia
| | - Maria Natividad Gómez-Cerezo
- The University of Queensland, School of Dentistry, Brisbane, QLD 4006, Australia
- The University of Queensland, School of Dentistry, Center for Oral-facial Regeneration, Rehabilitation and Reconstruction (COR3), Brisbane, QLD 4006, Australia
| | - Sašo Ivanovski
- The University of Queensland, School of Dentistry, Brisbane, QLD 4006, Australia
- The University of Queensland, School of Dentistry, Center for Oral-facial Regeneration, Rehabilitation and Reconstruction (COR3), Brisbane, QLD 4006, Australia
| |
Collapse
|
42
|
Wang X, Zhang Z, Wu G, Xu C, Wu J, Zhang X, Liu J. Applications of electrochemical biosensors based on functional antibody-modified screen-printed electrodes: a review. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 14:7-16. [PMID: 34877580 DOI: 10.1039/d1ay01570b] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The detection of biomolecular analytes is of great importance in clinical, environmental, and argo-food areas, among which the electrochemical methodology is attracting much attention. In particular, screen-printed electrode (SPE)-based sensing applications have exhibited potential possibility for on-site detection, especially for fast clinical biomarker detection, since they provide a miniaturized but robust and portable electrode detection system. In this context, we focused on the modification of SPE with functional antibodies to improve the electrochemical detection performance in versatile sensing applications, particularly for COVID-19 detection. These antibodies were immobilized onto the electrode surface via various methodologies, through which the powerful potential from the modification of SPE was revealed. Finally, more novel and excellent works on the biomolecular modification of SPE and the prospects of this technology from its state-of-art status to commercialization are previewed and future perspectives in this field are mentioned.
Collapse
Affiliation(s)
- Xuyao Wang
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| | - Zhenqi Zhang
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| | - Guolin Wu
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| | - Chunxia Xu
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| | - Jianping Wu
- Department of Clinical Laboratory, Zhejiang University School of Medicine First Affiliated Hospital, Hangzhou, Zhejiang, 310003, P. R. China
| | - Xingguo Zhang
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| | - Jian Liu
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| |
Collapse
|
43
|
Rocha DP, Rocha RG, Castro SVF, Trindade MAG, Munoz RAA, Richter EM, Angnes L. Posttreatment of 3D‐printed surfaces for electrochemical applications: A critical review on proposed protocols. ELECTROCHEMICAL SCIENCE ADVANCES 2021. [DOI: 10.1002/elsa.202100136] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Affiliation(s)
- Diego P. Rocha
- Instituto de Química Universidade de São Paulo Sao Paulo Brazil
| | - Raquel G. Rocha
- Instituto de Química Universidade Federal de Uberlândia berlândia Brazil
| | | | - Magno A. G. Trindade
- Faculdade de Ciências Exatas e Tecnologia Universidade Federal da Grande Dourados Dourados Brazil
- UNESP Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT‐DATREM) National Institute for Alternative Technologies of Detection Institute of Chemistry Araraquara Brazil
| | | | - Eduardo M. Richter
- Instituto de Química Universidade Federal de Uberlândia berlândia Brazil
| | - Lucio Angnes
- Instituto de Química Universidade de São Paulo Sao Paulo Brazil
| |
Collapse
|