1
|
Madeira L, Weber KR, Carpenedo N, Zhang Y, Porto TS, Meira JBC, Gonzaga CC, Kaizer MR. Effect of elastic gradients on the fracture resistance of tri-layer restorative systems. Dent Mater 2024; 40:1862-1871. [PMID: 39209606 PMCID: PMC11563891 DOI: 10.1016/j.dental.2024.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2024] [Revised: 08/07/2024] [Accepted: 08/15/2024] [Indexed: 09/04/2024]
Abstract
OBJECTIVES To assess the impact of elastic gradients formed among restorative material, cement, and substrate on the fracture resistance of tri-layer restorative systems. METHODS Four CAD/CAM materials were utilized, two glass-ceramics (IPS e.max CAD, Vita Suprinity) and two resin-ceramic hybrids (Vita Enamic, Lava Ultimate). Their fracture resistance was examined by biaxial flexure (n = 8) and Hertzian indentation (n = 10) tests. Statistical analysis was conducted using ANOVA and Tukey tests (p = 5 %). Finite element analysis (FEA) was employed to simulate the Hertzian indentation test and elucidate the stress-fields formed on the intaglio surface below the loading area. RESULTS The biaxial flexural strength (MPa) of glass-ceramics exceeded the hybrid materials (e.max 417a, Suprinity 230b, Enamic 138c, and Lava Ultimate 183bc). Conversely, the load-bearing capacity (N) of the materials bonded to dentin analog demonstrated the opposite trend, with the hybrid materials achieving superior results (e.max 830 C, Suprinity 660D, Enamic 1822B, and Lava Ultimate 2593 A). The stress-fields observed by FEA were coherent with the experimental results for Hertzian flexural stresses (MPa): e.max 501 A, Suprinity 342 C, Enamic 406B, whereas no tensile stress was observed at the intaglio surface of Lava Ultimate. SIGNIFICANCE Detailed analysis of the fracture resistance of the tri-layer restorative systems showed that the elastic gradients play a more significant role than the flexural strength of the restorative materials. The coherence of the elastic moduli between the restorative material and supporting structures results in reduced tensile stress concentration at the intaglio surface beneath the loading area and enhances the ability to withstand load.
Collapse
Affiliation(s)
| | | | | | - Yu Zhang
- School of Dental Medicine, University of Pennsylvania, USA.
| | | | | | | | | |
Collapse
|
2
|
Bashary N, Brewster J, Gill P, Janal MN, Özcan M, Al-Haj Husain N, Zhang Y. Long-Term Bonding Efficacy of CAD/CAM Hybrid Restorative Materials and Universal Adhesives. THE EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY 2024; 32:270-276. [PMID: 38591503 PMCID: PMC11412783 DOI: 10.1922/ejprd_2455bashary07] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 03/25/2024] [Indexed: 04/10/2024]
Abstract
OBJECTIVES In-office and lab milled prostheses are the staple for indirect restorations. It is therefore critical to determine their long-term bonding durability. METHODS CAD/ CAM blocks of two classes of restorative materials: 1) a nano-ceramic reinforced polymer matrix (NCPM) and, 2) a polymer-infiltrated ceramic network (PICN) were bonded using four different universal adhesives (UA) and silane systems. A lithium disilicate glassceramic (LDS) was used as a reference. The blocks were bisected and bonded with different UA/resin-cement pairs. Bonded blocks were then cut into 1.0x1.0x12.0 mm bar specimens for microtensile bond testing. Half the bars were subjected to bond strength testing immediately and the other half after aging by 50,000 thermal cycles between 5°C and 55°C. ANOVA and post-hoc tests were used to compare mean bond strength among groups. RESULTS NCPM presented consistently high bond strength regardless of bonding techniques, while the bond strength of PICN and LDS were lower when bonded with UA relative to traditional silanes. The more hydrophilic UA produced higher bond strengths. DISCUSSION Glass-ceramics exhibited lower bond strength with UA than the conventional etch-rinse-silane techniques. However, UAs preserved bonding interface in the long-term. SIGNIFICANCE NCPM displayed superior bond strength relative to PICN and LDS regardless of the type of adhesives and bonding techniques.
Collapse
Affiliation(s)
- N Bashary
- Department of Biomaterials & Biomimetics, New York University College of Dentistry, NY, USA
| | - J Brewster
- Director of Graduate Dental Research, 81st Dental Squadron, Keesler Air Force Base, MS, USA
| | - P Gill
- Department of Biomaterials & Biomimetics, New York University College of Dentistry, NY, USA
| | - M N Janal
- Professor at the Department of Epidemiology and Health Promotion, New York University College of Dentistry, NY, USA
| | - M Özcan
- Professor and Head, Clinic for Masticatory Disorders and Dental Biomaterials, University of Zurich, Zurich, Switzerland
| | - N Al-Haj Husain
- Specialization Candidate, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Switzerland
| | - Y Zhang
- Professor and Director for Restorative Research, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, PA, USA
| |
Collapse
|
3
|
Crins LAMJ, Opdam NJM, Huysmans MCDNJM, Zhang Y, Loomans BAC. An in vitro evaluation of the fatigue behavior of resin composite materials as part of a translational research cycle. Dent Mater 2024; 40:1409-1416. [PMID: 38926014 PMCID: PMC11330355 DOI: 10.1016/j.dental.2024.06.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 06/05/2024] [Indexed: 06/28/2024]
Abstract
PURPOSE This study aimed to reproduce and translate clinical presentations in an in vitro set-up and evaluate laboratory outcomes of mechanical properties (flexural strength, fatigue resistance, wear resistance) and link them to the clinical outcomes of the employed materials in the Radboud Tooth Wear Project (RTWP). MATERIALS AND METHODS Four dental resin composites were selected. 30 discs (Ø12.0 mm, 1.2 mm thick) were fabricated for each of Clearfil TM AP-X (AP), Filtek TM Supreme XTE (FS), Estenia TM C&B (ES), and Lava Ultimate (LU). Cyclic loading (200 N, 2 Hz frequency) was applied concentrically to 15 specimens per group with a spherical steatite indenter (r = 3.18 mm) in water in a contact-load-slide-liftoff motion (105 cycles). The wear scar was analysed using profilometry and the volume loss was digitally computed. Finally, all specimens were loaded (fatigued specimens with their worn surface loaded in tension) until fracture in a biaxial flexure apparatus. The differences in volume loss and flexural strength were determined using regression analysis. RESULTS Compared to AP and FS, ES and LU showed a significantly lower volume loss (p < 0.05). Non-fatigued ES specimens had a similar flexural strength compared to nonfatigued AP, while non-fatigued FS and LU specimens had a lower flexural strength (p < 0.001; 95 %CI: -80.0 - 51.8). The fatigue test resulted in a significant decrease of the flexural strength of ES specimens, only (p < 0.001; 95 %CI: -96.1 - -54.6). CLINICAL RELEVANCE These outcomes concur with the outcomes of clinical studies on the longevity of these composites in patients with tooth wear. Therefore, the employed laboratory test seems to have the potential to test materials in a clinically relevant way.
Collapse
Affiliation(s)
- L A M J Crins
- Radboud University Medical Center, Department of Dentistry, P.O. Box 9101, Nijmegen 6525 EX, the Netherlands.
| | - N J M Opdam
- Radboud University Medical Center, Department of Dentistry, P.O. Box 9101, Nijmegen 6525 EX, the Netherlands
| | - M C D N J M Huysmans
- Radboud University Medical Center, Department of Dentistry, P.O. Box 9101, Nijmegen 6525 EX, the Netherlands
| | - Y Zhang
- Department of Preventive & Restorative Sciences, School of Dental Medicine, University of Pennsylvania, 109 Levy Buidling, Philadelphia, USA
| | - B A C Loomans
- Radboud University Medical Center, Department of Dentistry, P.O. Box 9101, Nijmegen 6525 EX, the Netherlands
| |
Collapse
|
4
|
Çakmak G, Donmez MB, Molinero-Mourelle P, Kahveci Ç, Abou-Ayash S, Peutzfeldt A, Yilmaz B. Fracture resistance of additively or subtractively manufactured resin-based definitive crowns: Effect of restorative material, resin cement, and cyclic loading. Dent Mater 2024; 40:1072-1077. [PMID: 38777731 DOI: 10.1016/j.dental.2024.05.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 05/15/2024] [Indexed: 05/25/2024]
Abstract
OBJECTIVE To evaluate how restorative material, resin cement, and cyclic loading affect the fracture resistance of resin-based crowns fabricated by using additive or subtractive manufacturing. METHODS A right first molar crown standard tessellation language (STL) file was used to fabricate 120 crowns from one subtractively manufactured polymer-infiltrated ceramic network (SM) and two additively manufactured resin composites (AM-B and AM-S) (N = 40). These crowns were randomly divided into 4 groups within each material according to the dual-polymerizing resin cement to be used (RX and PN) and the aging condition (n = 10). After cementation, the crowns without cyclic loading were subjected to fracture testing, while the others were first cyclically loaded (1.7 Hz, 1.2 million cycles, and 49-N load) and then subjected to fracture testing. Data were analyzed with generalized linear model analysis (α = .05). RESULTS Fracture resistance of the crowns was affected by material, resin cement, and cyclic loading (P ≤ .030). However, none of the interactions significantly affected fracture resistance of tested crowns (P ≥ .140). Among tested materials, SM had the highest fracture resistance, whereas AM-B had the lowest (P ≤ .025). RX led to higher fracture resistance, and cyclic loading decreased the fracture resistance (P ≤ .026). SIGNIFICANCE Tested materials can be considered reliable in terms of fracture resistance in short- or mid-term (5 years of intraoral simulation) when used for single molar crowns with 2 mm occlusal thickness. In the long term, polymer-infiltrated ceramic network crowns cemented with RelyX Universal may provide promising results and be less prone to complications considering higher fracture resistance values obtained.
Collapse
Affiliation(s)
- Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Mustafa Borga Donmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey.
| | - Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, Madrid, Spain
| | | | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Anne Peutzfeldt
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, OH, USA
| |
Collapse
|
5
|
Alahmad AM, Alenezi AY, Rayyan M, Abdelhamid AI, Farag RA, Basta DG, Rifai H, Sayed M, Fouad M. Static Loading of Different Intraradicular Preparation Depths of Trinia Endocrowns in Maxillary Canines. J Contemp Dent Pract 2024; 25:575-580. [PMID: 39364824 DOI: 10.5005/jp-journals-10024-3714] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/05/2024]
Abstract
AIM The aim of this study is to compare the fracture resistance of canine teeth restored using TRINIA Endocrowns with three different types of preparations (2, 3, and 4 intracanal preparations). MATERIALS AND METHODS Thirty maxillary-extracted canines were collected. All teeth were fixed in orthodontic acrylic resin and decapitated at the level of the proximal cemento-enamel junction (CEJ). After being endodontically treated, specimens were distributed equally between 3 groups (n = 10) with different preparation depths (GT: 2 mm Intraradicular Preparation, GH: 3 mm Intraradicular Preparation, GF: 4 mm Intraradicular Preparation). Thirty TRINIA endocrowns were dry milled. After surface treatment, all endocrowns were bonded to their corresponding roots using Permaflo a dual-cure resin cement. Each specimen was then fixed in the lower part of a universal testing machine with a load cell of 5 KN, at an angle of 45 degrees to the tooth long-axis at 0.5 mm/min crosshead speed. Failure loads were recorded in Newton's. Data were recorded, organized, and statistically investigated. RESULTS Shapiro-Wilk tests revealed that the data were not normally distributed. Descriptive statistics revealed a high mean fracture resistance of GH (647 N), then GT (475.6 N), and finally GF (353.9 N). The Kruskal-Wallis test revealed a significant difference that existed between the groups being studied (p = 0.036). CONCLUSION TRINIA endocrowns with intracanal preparations of 2 and 3 mm provide more promising fracture resistance than those with intracanal preparations of 4 mm as a way of treating of root-canal-treated maxillary canines. TRINIA endocrowns (2 and 3 mm intracanal preparations) are as promising as fiber posts and all ceramic crowns in terms of fracture resistance. TRINIA endocrowns with 2 mm intracanal preparations are mostly reparable after failure, but those of 3 and 4 mm are mostly irreparable after failure. CLINICAL SIGNIFICANCE Modifying endocrowns to have intraradicular projections, simulating Nayyar core, may improve the success and longevity of endocrowns in anterior teeth. How to cite this article: Alahmad AM, Alenezi AY, Rayyan M, et al. Static Loading of Different Intraradicular Preparation Depths of Trinia Endocrowns in Maxillary Canines. J Contemp Dent Pract 2024;25(6):575-580.
Collapse
Affiliation(s)
- Ahmad M Alahmad
- Department of Primary Care, Alahmadi Dental Administration, Ministry of Health, Kuwait
| | - Abdullah Y Alenezi
- Department of Primary Care, Alahmadi Dental Administration, Ministry of Health, Kuwait
| | - Mohammad Rayyan
- Department of Prosthodontics, Sinai University, Kantara Campus, Sinai, Egypt
| | - Alaa I Abdelhamid
- Department of Periodontology and Implant Dentistry, College of Dentistry, Qassim University, Kingdom of Saudi Arabia
| | - Rehab Ali Farag
- Department of Endodontics, Faculty of Oral and Dental Surgery, Misr University for Science & Technology, Giza, Egypt
| | - Doaa Gamal Basta
- Department of Endodontics, Faculty of Dentistry, Sinai University, Kantara Campus, Egypt
| | | | - Mohamed Sayed
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ahram Canadian University, Egypt, Phone: +201288670943, e-mail:
| | - Maha Fouad
- Department of Fixed Prosthodontics, Faculty of Dentistry, Galala University, Egypt
| |
Collapse
|
6
|
Ikemoto S, Nagamatsu Y, Masaki C, Hosokawa R, Ikeda H. Development of zirconia-based polymer-infiltrated ceramic network for dental restorative material. J Mech Behav Biomed Mater 2024; 150:106320. [PMID: 38134584 DOI: 10.1016/j.jmbbm.2023.106320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 12/09/2023] [Accepted: 12/11/2023] [Indexed: 12/24/2023]
Abstract
Polymer-infiltrated ceramic network (PICN) materials have gained considerable attention as tooth restorative materials owing to their mechanical compatibility with human teeth. However, the mechanical strength of contemporary PICN materials is lower than those of conventional resin composites and ceramics. This study aims to develop novel high-strength PICN for use as a dental restorative material. Zirconia-based PICN (EXP) was fabricated using 3 mol% yttria tetragonal polycrystalline zirconia powder and resin monomers via slip casting, followed by sintering and polymer infiltration. Comprehensive analyses of the microstructure, mechanical properties, and physicochemical properties of EXP were performed using scanning electron microscopy with energy-dispersive X-ray spectroscopy, Fourier transform infrared spectroscopy, inorganic content measurements, three-point bending test, Vickers hardness test, two-body wear test, shear bond strength (SBS) test, surface free energy analysis, and water sorption/solubility test. Commercially available computer-aided design/computer-aided manufacturing (CAD/CAM) materials, including resin composite (CERASMART), silicate-based PICN (ENAMIC), and zirconia ceramic (e.max ZirCAD), were used for comparison. The analyses highlight the dual network structure of EXP, which comprised a zirconia skeleton and an infiltrated resin phase. EXP exhibits a flexural strength of 346.0 ± 46.0 MPa, flexural modulus of 44.0 ± 3.7 GPa, and Vickers hardness of 440.1 ± 51.2 VHN. The mechanical properties of EXP are significantly higher than those of CERASMART and ENAMIC but lower than those of ZirCAD. Notably, the EXP hardness closely mimics that of the human enamel. The wear volume, SBS, and water sorption/solubility of EXP are comparable to those of CERASMART and ENAMIC. Therefore, EXP has potential applications as a tooth restorative material.
Collapse
Affiliation(s)
- Soshi Ikemoto
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan; Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan
| | - Yuki Nagamatsu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan
| | - Chihiro Masaki
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan
| | - Ryuji Hosokawa
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan
| | - Hiroshi Ikeda
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan.
| |
Collapse
|
7
|
Rizzatto LV, Meneghetti D, Di Domênico M, Facenda JC, Weber KR, Corazza PH, Borba M. Effect of the type of resin cement on the fracture resistance of chairside CAD-CAM materials after aging. J Adv Prosthodont 2023; 15:136-144. [PMID: 37441719 PMCID: PMC10333098 DOI: 10.4047/jap.2023.15.3.136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 06/05/2023] [Accepted: 06/20/2023] [Indexed: 07/15/2023] Open
Abstract
PURPOSE The study objective was to evaluate the influence of the type of resin cement on the flexural strength and load to fracture of two chairside CAD-CAM materials after aging. MATERIALS AND METHODS A polymer-infiltrated ceramic network (PICN) and a nanoceramic resin (RNC) were used to produce the specimens. Two types of dual-cure resin cements, a self-adhesive and a universal, were investigated. Bilayer specimens were produced (n = 10) and aged for 6 months in a humid environment before the biaxial flexural strength test (σf). Bonded specimens were subjected to a mechanical aging protocol (50 N, 2 Hz, 37℃ water, 500,000 cycles) before the compressive load test (Lf). σf and Lf data were analyzed using two-way ANOVA and Tukey tests (α = .05). Chi-square test was used to analyze the relationship between failure mode and experimental group (α = .05). RESULTS The type of resin cement and the interaction between factors had no effect on the σf and Lf of the specimens, while the type of restorative material was significant. RNC had higher σf and Lf than PICN. There was a significant association among the type of cracks identified for specimens tested in Lf and the restorative material. CONCLUSION The type of resin cement had no effect on the flexural strength and load to fracture of the two investigated CAD-CAM chairside materials after aging.
Collapse
Affiliation(s)
| | - Daniel Meneghetti
- School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
| | - Marielle Di Domênico
- Graduate Program in Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
| | - Júlia Cadorin Facenda
- Graduate Program in Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
- Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil
| | - Katia Raquel Weber
- Graduate Program in Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
- Department of Dentistry, School of Health Sciences, Positivo University, Curitiba, PR, Brazil
| | | | - Márcia Borba
- Graduate Program in Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
| |
Collapse
|
8
|
Nascimento VA, Bento VAA, Cruz KH, Rosa CDDRD, Pesqueira AA, Pellizzer EP. Evaluation of bond strength of glass and resin-ceramics with laser phototherapy: A systematic review and meta-analysis of in vitro studies. J Prosthet Dent 2023:S0022-3913(23)00104-X. [PMID: 36898868 DOI: 10.1016/j.prosdent.2023.02.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 02/03/2023] [Accepted: 02/06/2023] [Indexed: 03/11/2023]
Abstract
STATEMENT OF PROBLEM Laser phototherapy has been studied as a surface treatment capable of increasing the adhesion of cement to the ceramic surface. However, the bond strength of glass and resin-ceramics after laser phototherapy is unclear. PURPOSE The objective of this systematic review and meta-analysis was to compare the bond strength of glass and resin-ceramics using laser therapy and conventional hydrofluoric acid etching. MATERIAL AND METHODS This systematic review and meta-analysis followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and was registered in the Open Science Framework (OSF) for in vitro studies. A population, intervention, control, and outcome (PICO) question was formulated: "Does phototherapy promote better bond strength in glass and resin-ceramics than conventional hydrofluoric acid etching?" A literature search was performed in PubMed/MEDLINE, Embase, Web of Science, Scopus, Cochrane Library, and ProQuest databases up to January 2023. The Joanna Briggs Institute critical assessment guidelines for quasi-experimental studies were used for quality assessment. The meta-analysis was based on the inverse variance (IV) method (α=.05). RESULTS A total of 6 in vitro studies published between 2007 and 2019 with a total number of 348 specimens were included for qualitative analysis; 1 study had a positive effect. Five of the studies were included in the meta-analysis, which indicated a significant decrease for feldspathic ceramics that received laser phototherapy and lithium disilicate (P=.002; MD: -2.15; 95% CI: -3.53 to -0.77; I2=89%, P<.01) and (P<.01; MD: -2.13; 95% CI: -2.99 to -1.27; I2=82%, P<.01), respectively. CONCLUSIONS Laser irradiation as surface etching of glass ceramics does not produce a bond strength equal to that of conventional hydrofluoric acid etching.
Collapse
Affiliation(s)
- Victor Alves Nascimento
- Post-Graduate student, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), SP, Brazil.
| | - Victor Augusto Alves Bento
- Post-Graduate student, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), SP, Brazil
| | - Kevin Henrique Cruz
- Post-Graduate student, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), SP, Brazil
| | - Cleber Davi Del Rei Daltro Rosa
- Post-Graduate student, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), SP, Brazil
| | - Aldiéris Alves Pesqueira
- Professor, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), Araçatuba, SP, Brazil
| | - Eduardo Piza Pellizzer
- Full Professor, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University (UNESP), Araçatuba, SP, Brazil
| |
Collapse
|
9
|
Jin C, Deng J, Pan P, Xiong Y, Zhu L, Gao S. Comparative study on the impact-sliding wear behaviour of CAD/CAM resin-ceramic materials and tooth enamel. Dent Mater 2023; 39:25-40. [PMID: 36456379 DOI: 10.1016/j.dental.2022.11.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Revised: 10/05/2022] [Accepted: 11/11/2022] [Indexed: 11/29/2022]
Abstract
OBJECTIVES To compare the impact-sliding wear of different CAD/CAM resin-ceramic materials and tooth enamel, and explore the corresponding wear damage mechanism. METHODS Human tooth enamel (EN), Vita ENAMIC (Vita, VE), Lava Ultimate (3 M, LU), and GC CERASMART (GC, CS) were used in this study. The hardness, elastic modulus, and roughness values of the samples were measured. Further, impact-sliding wear tests were performed in a ball-on-flat configuration with spherical zirconia antagonists and the coefficients of friction (CoF) were recorded simultaneously. Additionally, a white light interferometer was used to determine the volume losses and scanning electron microscopy was used to observe the wear morphology of the wear scars and the damage feature in the vertical sections to clarify the damage mechanism during the impact-sliding wear test. RESULTS EN exhibited the highest elastic modulus and CoF, followed by VE, LU, and CS. The hardness and roughness of EN and VE were similar and were higher than those of LU and CS. Throughout the wear tests, VE exhibited the highest volume loss, whereas CS exhibited the lowest. The wear damage characteristics of VE were similar to those of EN, displaying brittle fractures of inorganic substances and plastic deformation of organic substances in the impact part, exhibiting plough marks in the sliding parts. In the case of LU and CS, the entire wear areas displayed plastic deformation of the resin matrix, exfoliation of the filler particles, and plough marks. SIGNIFICANCE Enamel and polymer-infiltrated ceramic network materials exhibit similar wear damage modes. Additionally, the high-density nanocomposite resin material is the most resistant to impact-sliding wear from a tribological perspective.
Collapse
Affiliation(s)
- Chunxiao Jin
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| | - Jiuhong Deng
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| | - Peiyue Pan
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| | - Yuhuan Xiong
- Department of Stomatology, The First People's Hospital of Longquanyi District, Chengdu, Sichuan 610100, China
| | - Liqing Zhu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| | - Shanshan Gao
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China.
| |
Collapse
|
10
|
Sodergren B, Wang J, Zhang Y, Kim J. Fracture resistance of Ceramic-Polymer hybrid materials using microscopic finite element analysis and experimental validation. Comput Methods Biomech Biomed Engin 2022; 25:1785-1795. [PMID: 35147471 PMCID: PMC9899050 DOI: 10.1080/10255842.2022.2038141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 01/26/2022] [Accepted: 02/01/2022] [Indexed: 02/06/2023]
Abstract
The objective of this paper is to elucidate the response to contact stresses of Polymer Infiltrated Ceramic Network (PICN) using the microscopic viscoplastic finite elements, validated by clinically relevant in vitro tests. A feldspathic ceramic material, namely Vita Mark II, is an interconnected structure infiltrated with the polymer (PMMA). Axisymmetric finite element microstructure models are reconstructed from two-dimensional images of a PICN microstructure. Viscoplastic finite element analysis (FEA) with various degrees of microscopic damages occurring over contact is performed. The force-displacement responses obtained from FEA are validated with Hertzian contact tests. Finite element results for force-displacement, stresses and strains in each phase are discussed. We hypothesize that the resistance to fracture of PICN can be further improved by microstructural tailoring. The experimental evidence suggests that a composite material is both more resistant to displacement under load and more resistant to crack initiation and propagation, as hypothesized. Further parametric study on the effects of various volume fractions of two phases in PICN is done to provide some insight on increased contact damage resistance of PICN as well as potential optimization of microstructures.
Collapse
Affiliation(s)
- Brendan Sodergren
- Department of Civil and Environmental Engineering, University of Connecticut, Storrs, CT, USA
| | - Jing Wang
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY
| | - Yu Zhang
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA
| | - Jeongho Kim
- Department of Civil and Environmental Engineering, University of Connecticut, Storrs, CT, USA
| |
Collapse
|
11
|
Post-Fatigue Fracture Resistance of Lithium Disilicate and Polymer-Infiltrated Ceramic Network Indirect Restorations over Endodontically-Treated Molars with Different Preparation Designs: An In-Vitro Study. Polymers (Basel) 2022; 14:polym14235084. [PMID: 36501478 PMCID: PMC9739407 DOI: 10.3390/polym14235084] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 11/11/2022] [Accepted: 11/18/2022] [Indexed: 11/25/2022] Open
Abstract
The aim of the present study was to evaluate the fatigue to cyclic and static resistance of indirect restorations with different preparation designs made either of lithium disilicate (LS) or polymer-infiltrated ceramic network (PICN). Eighty-four (n = 84) molars were chosen, endodontically treated, and prepared with standardized MOD cavities. The molars were randomly divided into 6 study groups (n = 14) taking into account the "preparation design'' (occlusal veneer with 1.2 mm occlusal thickness; overlay with 1.6 mm occlusal thickness; adhesive crown with 2 mm occlusal thickness) and the "CAD/CAM material'' (E-max CAD, Ivoclar vivadent; Vita Enamic, Vita). A fatigue test was conducted with a chewing simulator set at 50 N for 1,500,000 cycles. Fracture resistance was assessed using a universal testing machine with a 6 mm diameter steel sphere applied to the specimens at a constant speed of 1 mm/min. A SEM analysis before the fracture test was performed to visually analyze the tooth-restoration margins. A statistical analysis was performed with a two-way ANOVA and a post-hoc pairwise comparison was performed using the Tukey test. The two-way ANOVA test showed that both the preparation design factor (p = 0.0429) and the CAD/CAM material factor (p = 0.0002) had a significant influence on the fracture resistance of the adhesive indirect restorations. The interaction between the two variables did not show any significance (p = 0.8218). The occlusal veneer had a lower fracture resistance than the adhesive crown (p = 0.042) but not lower than the overlay preparation (p = 0.095). LS was more resistant than PICN (p = 0.002). In conclusion, in the case of endodontically treated teeth, overlay preparation seems to be a valid alternative to the traditional full crown preparation, while occlusal veneers should be avoided in restoring non-vital molars with a high loss of residual tooth structure. LS material is more resistant compared to PICN.
Collapse
|
12
|
Güleç C, Sarıkaya I. The influence of aging on the fracture load of milled monolithic crowns. BMC Oral Health 2022; 22:516. [PMCID: PMC9675227 DOI: 10.1186/s12903-022-02529-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 10/24/2022] [Indexed: 11/21/2022] Open
Abstract
Background This in-vitro study was conducted to assess the effect of aging on the fracture load of molar crowns fabricated with monolithic CAD/CAM materials. Methods The crown restorations were produced from Cerasmart, Vita Enamic, and IPS e.max CAD blocks. Aging was applied to the 10 samples each of monolithic CAD/CAM materials (n = 10). Dual-axis chewing simulator (50 N, 1.1 Hz, lateral movement: 1 mm, mouth opening: 2 mm, 1,200,000 cycles) and thermocycling (± 5–55 °C, 6000 cycles) were applied as an aging procedure. 10 samples each of monolithic CAD/CAM materials without aging (n = 10) were considered the control group. 6 tested groups were obtained. Then, all samples were evaluated in a universal testing machine to determine the fracture loading values’. Results There was not a statistically significant difference between the fracture load values before and after aging for all samples of Cerasmart, Vita Enamic, and IPS e.max CAD (p > 0.005). In a comparison of the monolithic materials together, a statistically significant difference was found between the fracture load values of IPS e.max CAD and Vita Enamic crowns before aging (p = 0.02). Also, Vita Enamic crowns (1978,71 ± 364,05 N) were found different from the IPS e.max CAD (p = 0.005) and Cerasmart crowns (p = 0.041) after aging. Conclusions Dynamic aging with 1.200.000 cycles was found to have no effect to fracture loading on milled Cerasmart, Vita Enamic, and IPS e.max CAD monolithic crowns.
Collapse
Affiliation(s)
- Ceyda Güleç
- grid.411550.40000 0001 0689 906XDepartment of Prosthodontics, Faculty of Dentistry, Tokat Gaziosmanpasa University, Ali Şevki Erek Campus, 60100 Tokat, Turkey
| | - Işıl Sarıkaya
- grid.411550.40000 0001 0689 906XDepartment of Prosthodontics, Faculty of Dentistry, Tokat Gaziosmanpasa University, Ali Şevki Erek Campus, 60100 Tokat, Turkey
| |
Collapse
|
13
|
Bashary N, Tashkandi A, Fan Y, Kaizer MR, Özcan M, Al-Haj Husain N, Zhang Y. Evaluating the Bond Strength of a Polymer Infiltrated Ceramic Network to Zirconia Using the Crossbeam Push-Off Method. THE EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY 2022; 30:207-213. [PMID: 35023665 PMCID: PMC9897972 DOI: 10.1922/ejprd_2348bashary07] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Porcelains and glass-ceramics have been used to produce CAD-milled veneers and crowns for zirconia copings and implant-abutments. This study evaluated the bondstrength of a polymer-infiltrated-ceramic-network to zirconia using two adhesive cement systems: Panavia 21 and Multilink Automix. Lithium disilicate and feldspathic porcelain were also tested as reference CAD-On materials. Long beams (3x6x40 mm³) of zirconia and short beams (3x6x15 mm³) of the CAD-On materials were prepared. Zirconia and each CAD-On material were bonded in a crossbeam arrangement and subjected to a modified tensile bond-strength test. Half of the samples in each group (n=10) were tested 5 days after bonding (baseline) and the remaining (n=10) underwent aging (50,000 thermocycles at 5°C and 55°C) prior to bond-strength testing. The effects of material, cement, and aging on the tensile bond-strength were tested using a three-way ANOVA. The reference lithium disilicate/Multilink system showed no significant differences in bond strength compared to polymer-infiltrated-ceramic-network and porcelain. The long-term retention of polymer-infiltrated-ceramic-network was not statistically different compared to the baseline values and the two reference materials. With comparable bond strength between all materials, polymer-infiltrated-ceramic-network is the favorable choice for CAD-On to zirconia copings and implant-abutments due to its superior resistance to fatigue fracture relative to porcelain.
Collapse
Affiliation(s)
- Nadav Bashary
- DDS student, Department of Biomaterials & Biomimetics, New York University College of Dentistry, 345 E. 24 Street, New York, NY 10010, USA
| | - Abeer Tashkandi
- Department of Restorative Sciences & Biomaterials, Boston University Henry M. Goldman School of Dental Medicine
| | - Yuwei Fan
- Research Associate Professor, Department of Restorative Sciences & Biomaterials, Boston University Henry M. Goldman School of Dental Medicine
| | - Marina R. Kaizer
- Professor, Graduate Program in Dentistry, Positivo University, Curitiba, PR 81280-330, Brazil
| | - Mutlu Özcan
- Professor and Head, Division of Dental Biomaterials, Clinic for Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland
| | - Nadin Al-Haj Husain
- Professor and Head, Division of Dental Biomaterials, Clinic for Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland
- Specialization Candidate, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3010 Bern, Switzerland
| | - Yu Zhang
- Professor and Director for Restorative Research, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, 240 S. 40 Street, Philadelphia, PA 19104, USA
| |
Collapse
|
14
|
Soliman M, Alzahrani G, Alabdualataif F, Eldwakhly E, Alsamady S, Aldegheishem A, Abdelhafeez MM. Impact of Ceramic Material and Preparation Design on Marginal Fit of Endocrown Restorations. MATERIALS (BASEL, SWITZERLAND) 2022; 15:5592. [PMID: 36013732 PMCID: PMC9414256 DOI: 10.3390/ma15165592] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 07/26/2022] [Accepted: 08/08/2022] [Indexed: 06/15/2023]
Abstract
Background: The aim of this study is to investigate the impact of ceramic material and preparation design on the marginal fit of endocrown restorations. Methods: Forty endocrown restorations were CAD/CAM-fabricated for forty extracted maxillary first premolar teeth. Samples were divided into two groups (n = 20) according to the ceramic materials used: Celtra Duo and Vita Enamic. Each group was divided into two subgroups (n = 10) according to the preparation design: with no intraradicular extension and with 3 mm intraradicular extension. The marginal gap was examined using a digital microscope. Results: Celtra Duo without intraradicular extension recorded the least mean marginal gap (7.74 ± 1.55 µm), while Group Celtra Duo with 3 mm intraradicular extension recorded the highest mean marginal gap (29.54 ± 6.32 µm). Group Vita Enamic recorded a lesser marginal gap (18.03 ± 12.11 µm) than group CD (Celtra Duo) (18.64 ± 12.05 µm). There is a statistically non-significant difference between the two groups of materials (p = 0.873). There is a statistically significant difference between the two tested preparation designs (p < 0.001). Conclusion: All groups recorded a marginal gap within clinically accepted values. Material selection may influence the fitting of restorations. Intraradicular extension for endocrown restorations adversely affects the marginal fit, however, the marginal gap is still within the clinically accepted range.
Collapse
Affiliation(s)
- Mai Soliman
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia or
| | - Ghadeer Alzahrani
- General Dentistry, College of Dentistry, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
| | - Foton Alabdualataif
- General Dentistry, College of Dentistry, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
| | - Elzahraa Eldwakhly
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia or
| | - Sahar Alsamady
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia or
| | - Alhanoof Aldegheishem
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia or
| | - Manal M. Abdelhafeez
- Department of Conservative Dental Sciences, College of Dentistry, Qassim University, P.O. Box 6688, Buraydah 51452, Saudi Arabia
- Faculty of Dentistry, October University for Modern Sciences and Arts, Giza 12451, Egypt
| |
Collapse
|
15
|
Novel Pathway for the Combustion Synthesis and Consolidation of Boron Carbide. MATERIALS 2022; 15:ma15145042. [PMID: 35888509 PMCID: PMC9323104 DOI: 10.3390/ma15145042] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 07/17/2022] [Accepted: 07/18/2022] [Indexed: 02/01/2023]
Abstract
A novel pathway for the magnesiothermic reduction of boron oxide and magnesium dodecaboride (MgB12) in the presence of carbon by a self-propagating high-temperature synthesis method was proposed that was aimed at the direct preparation of boron carbide nanopowder. The combined utilization of two boron sources, boron oxide and MgB12, allowed tailoring the overall caloric effect of the process, increasing the yield of the target product and lessening the laborious leaching process. In addition, it is an alternative way to utilize magnesium borides, which are inevitable side products at boron production. Multivariate thermodynamic calculations performed in the B2O3-MgB12-Mg-C system allowed estimating equilibrium compositions of the products and deducing the optimum composition of the initial mixture for obtaining B4C. For the latter, the adiabatic temperature (Tad) is 2100 °C, which is theoretically enough for the implementation of the self-propagating reaction. The combustion reaction was shown to be extremely sensitive to the initial mixture composition, external pressure, as well as sample diameter (heat losses). It proceeds in self-oscillatory mode and leads to the product of a layered macrostructure. The combustion product was then consolidated by the spark plasma sintering technique at different conditions. Vickers microhardness was measured, and the wear erosion behavior was examined. The variation in lattice parameters of boron carbide reflected the influence of synthesis, sintering and erosion conditions on the ordering/disordering of the boron carbide structure.
Collapse
|
16
|
Wahjuningrum DA, Norberto CRJ, Fernanda MML, Sari AA, Pawar AM, Cruz González AC. Micro-shear bond strength of different surface treatments on a polymer infiltrated ceramic network. F1000Res 2022; 11:798. [PMID: 37997604 PMCID: PMC10665602 DOI: 10.12688/f1000research.122108.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/11/2022] [Indexed: 11/25/2023] Open
Abstract
Background: Polymer infiltrated ceramic networks, or hybrid ceramics, are a combination of infiltrating polymerizable organic monomers into a pre-sintered porous ceramic matrix. In addition to having good mechanical properties, the polymer infiltrated ceramic network must comply with the possibility of adequate bonding to the resinous cement. The surface conditioning of this hybrid material must be carefully considered due to its organic composition and ceramic network. The purpose of this research is to evaluate the effect of hydrofluoric acid and a self-etching ceramic primer, under two different application times, on the bond strength of a polymer infiltrated ceramic network. Methods: Blocks of a polymer infiltrated ceramic network were cut to obtain sheets, and these were randomized into five groups. For the group termed AAS, airborne-particle abrasion with Al 2O 3 (aluminum oxide) of 50µm was used. For groups HF2 and HF6, hydrofluoric acid was used for 20 and 60 seconds respectively, and for the groups MB2 and MB6, a self-etch ceramic primer was applied for 20 and 60 seconds respectively. A silane was applied to the groups AAS, HF2, and HF6 after the treatment. After 24-hour storage in distilled water, a micro-shear bond strength test was performed using a universal mechanical testing machine. All samples were evaluated in a stereomicroscope at 40x and 50x to determine the type of failure. Results: The highest and lowest values of bond strength were reported by groups MB6 and AAS, respectively. Groups HF2, HF6, MB6, and MB2 did not report statistically significant differences. The predominant failure pattern was a mixed failure. Conclusions: With the limitations of the present investigation, the treatments of self-etching ceramic primer and hydrofluoric acid followed by silane were reported to be statistically equal at 20 and 60 seconds.
Collapse
Affiliation(s)
- Dian Agustin Wahjuningrum
- Department of Conservative Dentistry, Faculty of Dental Medicine, Universitas Airlangga, Surabaya, Indonesia
| | | | | | - Amanda Andika Sari
- Department of Conservative Dentistry, Faculty of Dental Medicine, Universitas Airlangga, Surabaya, Indonesia
| | - Ajinkya M. Pawar
- Department of Conservative Dentistry and Endodontics, Nair Hospital Dental College, Mumbai 400008, Maharashtra, India
| | | |
Collapse
|
17
|
Marian M, Berman D, Nečas D, Emani N, Ruggiero A, Rosenkranz A. Roadmap for 2D materials in biotribological/biomedical applications – A review. Adv Colloid Interface Sci 2022; 307:102747. [DOI: 10.1016/j.cis.2022.102747] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Revised: 07/26/2022] [Accepted: 07/28/2022] [Indexed: 01/01/2023]
|
18
|
Zong X, Qin B, Wang Y, Chen H, Peng L, Li X, Sun Y. Preliminary Exploration of a Laser-Based Surface Microtexturing Strategy for Improving the Wear Resistance of Dentin: An In Vitro Study. Photobiomodul Photomed Laser Surg 2022; 40:355-361. [DOI: 10.1089/photob.2021.0138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Xiao Zong
- Center of Digital Dentistry, Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, NHC Research Center of Engineering and Technology for Computerized Dentistry, Beijing, P.R. China
| | - Bin Qin
- Laser Micro/Nano Fabrication Laboratory, School of Mechanical Engineering, Beijing Institute of Technology, Beijing, P.R. China
| | - Yong Wang
- Center of Digital Dentistry, Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, NHC Research Center of Engineering and Technology for Computerized Dentistry, Beijing, P.R. China
| | - Hu Chen
- Center of Digital Dentistry, Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, NHC Research Center of Engineering and Technology for Computerized Dentistry, Beijing, P.R. China
| | - Li Peng
- Center of Digital Dentistry, Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, NHC Research Center of Engineering and Technology for Computerized Dentistry, Beijing, P.R. China
| | - Xiaowei Li
- Laser Micro/Nano Fabrication Laboratory, School of Mechanical Engineering, Beijing Institute of Technology, Beijing, P.R. China
| | - Yuchun Sun
- Center of Digital Dentistry, Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, NHC Research Center of Engineering and Technology for Computerized Dentistry, Beijing, P.R. China
| |
Collapse
|
19
|
Bai R, Sun Q, He Y, Peng L, Zhang Y, Zhang L, Lu W, Deng J, Zhuang Z, Yu T, Wei Y. Ceramic Toughening Strategies for Biomedical Applications. Front Bioeng Biotechnol 2022; 10:840372. [PMID: 35330627 PMCID: PMC8940218 DOI: 10.3389/fbioe.2022.840372] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 02/09/2022] [Indexed: 11/21/2022] Open
Abstract
Aiming at shortage of metal materials, ceramic is increasingly applied in biomedicine due to its high strength, pleasing esthetics and good biocompatibility, especially for dental restorations and implants, artificial joints, as well as synthetic bone substitutes. However, the inherent brittleness of ceramic could lead to serious complications, such as fracture and disfunction of biomedical devices, which impede their clinical applications. Herein, several toughening strategies have been summarized in this review, including reinforcing phase addition, surface modification, and manufacturing processes improvement. Doping metal and/or non-metal reinforcing fillers modifies toughness of bulk ceramic, while surface modifications, mainly coating, chemical and thermal methods, regulate toughness on the surface layer. During fabrication, optimization should be practiced in powder preparation, green forming and densification processes. Various toughening strategies utilize mechanisms involving fine-grained, stress-induced phase transformation, and microcrack toughening, as well as crack deflection, bifurcation, bridging and pull-out. This review hopes to shed light on systematic combination of different toughening strategies and mechanisms to drive progress in biomedical devices.
Collapse
Affiliation(s)
- Rushui Bai
- Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing, China.,National Engineering Laboratory for Digital and Material Technology of Stomatology and Beijing Key Laboratory of Digital Stomatology, Beijing, China
| | - Qiannan Sun
- Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing, China.,National Engineering Laboratory for Digital and Material Technology of Stomatology and Beijing Key Laboratory of Digital Stomatology, Beijing, China
| | - Ying He
- National Engineering Laboratory for Digital and Material Technology of Stomatology and Beijing Key Laboratory of Digital Stomatology, Beijing, China.,Department of Geriatric Dentistry, Peking University School and Hospital of Stomatology, Beijing, China
| | - Liying Peng
- Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing, China.,National Engineering Laboratory for Digital and Material Technology of Stomatology and Beijing Key Laboratory of Digital Stomatology, Beijing, China
| | - Yunfan Zhang
- Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing, China.,National Engineering Laboratory for Digital and Material Technology of Stomatology and Beijing Key Laboratory of Digital Stomatology, Beijing, China
| | - Lingyun Zhang
- Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing, China.,National Engineering Laboratory for Digital and Material Technology of Stomatology and Beijing Key Laboratory of Digital Stomatology, Beijing, China
| | - Wenhsuan Lu
- Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing, China.,National Engineering Laboratory for Digital and Material Technology of Stomatology and Beijing Key Laboratory of Digital Stomatology, Beijing, China
| | - Jingjing Deng
- National Engineering Laboratory for Digital and Material Technology of Stomatology and Beijing Key Laboratory of Digital Stomatology, Beijing, China.,Department of Geriatric Dentistry, Peking University School and Hospital of Stomatology, Beijing, China
| | - Zimeng Zhuang
- Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing, China.,National Engineering Laboratory for Digital and Material Technology of Stomatology and Beijing Key Laboratory of Digital Stomatology, Beijing, China
| | - Tingting Yu
- Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing, China.,National Engineering Laboratory for Digital and Material Technology of Stomatology and Beijing Key Laboratory of Digital Stomatology, Beijing, China
| | - Yan Wei
- National Engineering Laboratory for Digital and Material Technology of Stomatology and Beijing Key Laboratory of Digital Stomatology, Beijing, China.,Department of Geriatric Dentistry, Peking University School and Hospital of Stomatology, Beijing, China
| |
Collapse
|
20
|
Tokunaga J, Ikeda H, Nagamatsu Y, Awano S, Shimizu H. Wear of Polymer-Infiltrated Ceramic Network Materials against Enamel. MATERIALS 2022; 15:ma15072435. [PMID: 35407767 PMCID: PMC8999962 DOI: 10.3390/ma15072435] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 03/16/2022] [Accepted: 03/23/2022] [Indexed: 12/25/2022]
Abstract
Polymer-infiltrated ceramic network materials (PICNs) have high mechanical compatibility with human enamel. However, the wear properties of PICN against natural human enamel have not yet been clarified. We investigated the in vitro two-body wear behaviors of PICNs and an enamel antagonist. Two PICNs were used: Experimental PICN (EXP) prepared via the infiltration of methacrylate-based resin into the porous silica ceramic network and commercial Vita Enamic (ENA). Two commercial dental ceramics, lithium disilicate glass (LDS) and zirconia (ZIR), were also characterized, and their wear performance was compared to PICNs. The samples were subjected to Vickers hardness tests and two-body wear tests that involve the samples being cyclically impacted by enamel antagonists underwater at 37 °C. The results reveal that the Vickers hardness of EXP (301 ± 36) was closest to that of enamel (317 ± 17). The volumetric wear losses of EXP and ENA were similar to those of LDS but higher than that of zirconia. The volumetric wear loss of the enamel antagonist impacted against EXP was moderate among the examined samples. These results suggest that EXP has wear behavior similar to that of enamel. Therefore, PICNs are mechanically comparable to enamel in terms of hardness and wear and are excellent tooth-restoration materials.
Collapse
Affiliation(s)
- Jumpei Tokunaga
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Fukuoka 803-8580, Japan; (J.T.); (Y.N.); (H.S.)
- Division of Clinical Education Development and Research, Department of Oral Functions, Kyushu Dental University, Fukuoka 803-8580, Japan;
| | - Hiroshi Ikeda
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Fukuoka 803-8580, Japan; (J.T.); (Y.N.); (H.S.)
- Correspondence:
| | - Yuki Nagamatsu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Fukuoka 803-8580, Japan; (J.T.); (Y.N.); (H.S.)
| | - Shuji Awano
- Division of Clinical Education Development and Research, Department of Oral Functions, Kyushu Dental University, Fukuoka 803-8580, Japan;
| | - Hiroshi Shimizu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Fukuoka 803-8580, Japan; (J.T.); (Y.N.); (H.S.)
| |
Collapse
|
21
|
Feng X, Kou W, Liu H, Gong B, Tang C. Study on fracture behavior of molars based on three-dimensional high-precision computerized tomography scanning and numerical simulation. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2022; 38:e3561. [PMID: 34865323 DOI: 10.1002/cnm.3561] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Accepted: 12/02/2021] [Indexed: 06/13/2023]
Abstract
A series of three-dimensional (3D) numerical simulations are conducted to investigate the gradual failure process of molars in this study. The real morphology and internal mesoscopic structure of a whole tooth are implemented into the numerical simulations through computerized tomography scanning, digital image processing, and 3D matrix mapping. The failure process of the whole tooth subject to compressions including crack initiation, crack propagation, and final failure pattern is reproduced using 3D realistic failure process analysis (RFPA3D) method. It is concluded that a series of microcracks are gradually initiated, nucleated, and subsequently interconnect to form macroscopic cracks when the teeth are under over-compressions. The propagation of the macroscopic cracks results in the formation of fracture surfaces and penetrating cracks, which are essential signs and manifestations of the tooth failure. Moreover, the simulations reveal that, the material heterogeneity is a critical factor that affects the mechanical properties and fracture modes of the teeth, which vary from crown fractures to crown-root fractures and root fractures depending on different homogeneity indices.
Collapse
Affiliation(s)
- Xianhui Feng
- Faculty of Infrastructure Engineering, Dalian University of Technology, Dalian, China
| | - Wen Kou
- Dental Materials Science, Umeå University, Umeå, Sweden
| | - Hongyuan Liu
- College of Science and Engineering, University of Tasmania, Hobart, Australia
| | - Bin Gong
- Faculty of Infrastructure Engineering, Dalian University of Technology, Dalian, China
- Department of Civil and Environmental Engineering, Brunel University London, London, UK
| | - Chun'an Tang
- Faculty of Infrastructure Engineering, Dalian University of Technology, Dalian, China
| |
Collapse
|
22
|
Won S, Ko KH, Park CJ, Cho LR, Huh YH. Effect of barium silicate filler content on mechanical properties of resin nanoceramics for additive manufacturing. J Adv Prosthodont 2022; 14:315-323. [DOI: 10.4047/jap.2022.14.5.315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 09/21/2022] [Accepted: 10/17/2022] [Indexed: 11/10/2022] Open
Affiliation(s)
- Sun Won
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Kyung-Ho Ko
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Chan-Jin Park
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Lee-Ra Cho
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Yoon-Hyuk Huh
- Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| |
Collapse
|
23
|
Effect of Finish Line Design on the Fit Accuracy of CAD/CAM Monolithic Polymer-Infiltrated Ceramic-Network Fixed Dental Prostheses: An In Vitro Study. Polymers (Basel) 2021; 13:polym13244311. [PMID: 34960861 PMCID: PMC8705895 DOI: 10.3390/polym13244311] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 12/05/2021] [Accepted: 12/06/2021] [Indexed: 12/04/2022] Open
Abstract
A polymer-infiltrated ceramic network (PICN) material has recently been introduced for dental use and evidence is developing regarding the fit accuracy of such crowns with different preparation designs. The aim of this in vitro study was to evaluate the precision of fit of machined monolithic PICN single crowns in comparison to lithium disilicate crowns in terms of marginal gap, internal gap, and absolute marginal discrepancies. A secondary aim was to assess the effect of finish line configuration on the fit accuracy of crowns made from the two materials. Two master metal dies were used to create forty stone dies, with twenty each for the two finish lines, shoulder and chamfer. The stone dies were scanned to produce virtual models, on which ceramic crowns were designed and milled, with ten each for the four material–finish line combinations (n = 10). Marginal gaps and absolute marginal discrepancies were evaluated at six pre-determined margin locations, and the internal gap was measured at 60 designated points using a stereomicroscope-based digital image analysis system. The influence of the material and finish line on the marginal and internal adaptation of crowns was assessed by analyzing the data using two-way analysis of variance (ANOVA), non-parametric, and Bonferroni multiple comparison post-hoc tests (α = 0.05). ANOVA revealed that the differences in the marginal gaps and the absolute marginal discrepancies between the two materials were significant (p < 0.05), but that those the finish line effect and the interaction were not significant (p > 0.05). Using the Mann–Whitney U test, the differences in IG for ‘material’ and ‘finish line’ were not found to be significant (p > 0.05). In conclusion, the finish line configuration did not seem to affect the marginal and internal adaptation of PICN and lithium disilicate crowns. The marginal gap of PICN crowns was below the clinically acceptable threshold of 120 µm.
Collapse
|
24
|
Lan TH, Chen PH, Fok ASL, Chen YF. Contact fracture test of monolithic hybrid ceramics on different substrates for bruxism. Dent Mater 2021; 38:44-56. [PMID: 34785045 DOI: 10.1016/j.dental.2021.10.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Accepted: 10/26/2021] [Indexed: 11/27/2022]
Abstract
OBJECTIVES To determine the minimum thickness required for a monolithic hybrid ceramic crown on different substrates (soft vs stiff) used in posterior dentition for bruxism. METHODS 80 polymer-infiltrated ceramic networks Vita Enamic (PICN VE) disc specimens with four different occlusal thicknesses (0.8, 1.2, 1.6 and 2.0 mm), were produced using a computer-aided design/manufacturing system, and cemented on a stiff (zirconia) or soft (polyamide) substrate of 4-mm thickness. The ten specimens, in soft or stiff groups, were subjected to compressive loading by a MTS machine until fracture or maximum load (4500 N) was reached. The unbroken specimens were examined using optical coherence tomography. Eight axisymmetric finite element models and eight 3D models comprising the four different occlusal thicknesses and two substrates under different vertical loads and sliding movements were constructed. The maximum principal stress was selected to evaluate the stress distribution in this study. RESULTS The fracture resistance of the specimens was significantly different between the two substrates (P < 0.001). Fracture resistance was positively associated with specimen thickness (r = 0.597 and 0.896 for the soft and stiff substrate respectively). Specimens on the soft substrate had lower fracture loads, whilst cone cracks were observed in unbroken samples on different soft/stiff substrate prior to final fracture. The finite element analysis confirmed that samples on the stiff substrate had lower maximum principal stress values than those on the soft substrate. For the maximum principal stress not to exceed the flexural strength of PICN VE, a stiff substrate and minimum thickness of 2.0 mm are required for the prostheses. SIGNIFICANCE A minimum 2.0 mm thick, stiff substrate was needed for bruxism as shown by the effect of high/large chewing force on the posterior dentition of monolithic PICN VE crowns.
Collapse
Affiliation(s)
- Ting-Hsun Lan
- Division of Prosthodontics, Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung 807377, Taiwan, ROC; School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung 807378, Taiwan, ROC.
| | - Ping-Ho Chen
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung 807378, Taiwan, ROC.
| | - Alex Siu Lun Fok
- Minnesota Dental Research Center for Biomaterials and Biomechanics, University of Minnesota, 16-212 Moos Health Science Tower, 515 Delaware street S.E., Minneapolis, MN 55455, USA.
| | - Yu-Feng Chen
- Division of Oral Surgery, Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung 807377, Taiwan, ROC.
| |
Collapse
|
25
|
Wille S, Sieper K, Kern M. Wear resistance of crowns made from different CAM/CAD materials. Dent Mater 2021; 37:e407-e413. [PMID: 33875248 DOI: 10.1016/j.dental.2021.03.017] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 02/26/2021] [Accepted: 03/29/2021] [Indexed: 11/19/2022]
Abstract
OBJECTIVES The aim of this laboratory study was to evaluate the wear resistance of crowns made from current computer-aided design and computer-aided manufacture (CAD/CAM) materials. In addition, the abrasion of the steatite antagonist against these materials was compared. METHODS Identically shaped crowns of lithium disilicate, zirconia-reinforced lithium disilicate and a polymer-infiltrated ceramic network (PICN) were fabricated with an occlusal thickness of 1.5mm and a lateral wall thickness of 1.2mm (n=8). The crowns were cemented with a dual-polymerizing luting resin on composite resin dies. Using spherical steatite antagonists, all specimens were loaded with 49N for 1,200,000 cycles in a mastication simulator with additional thermocycling. After 120,000, 240,000, 480,000, 960,000, and 1,200,000 cycles, precision impressions were made and investigated with a laser scanning microscope. The vertical and volume substance loss was measured. Additionally, the substance loss of the antagonists was evaluated after 1,200,000 loading cycles. RESULTS No significant difference (p>0.05) was found in the median volume loss of the test materials after 1,200,000 cycles (lithium disilicate: 0.405mm3, PICN: 0.362mm3, zirconia-reinforced lithium disilicate: 0.340mm3). The vertical substance loss of PICN (157μm) was significantly lower (p≤0.05) than that of lithium disilicate (201μm) and zirconia reinforced lithium disilicate (191μm). However, the substance loss of steatite against zirconia-reinforced lithium disilicate (0.191mm3) was significantly lower (p≤0.05) than against lithium disilicate (0.296mm3) and PICN (0.531mm3). SIGNIFICANCE All three CAD/CAM materials showed wear resistance that seems appropriate for clinical application. Also, the abrasion of the antagonist looks promising.
Collapse
Affiliation(s)
- Sebastian Wille
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Germany.
| | - Kim Sieper
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Germany.
| | - Matthias Kern
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Germany.
| |
Collapse
|
26
|
PICN Nanocomposite as Dental CAD/CAM Block Comparable to Human Tooth in Terms of Hardness and Flexural Modulus. MATERIALS 2021; 14:ma14051182. [PMID: 33802326 PMCID: PMC7959134 DOI: 10.3390/ma14051182] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 02/25/2021] [Accepted: 02/26/2021] [Indexed: 12/14/2022]
Abstract
Polymer infiltrated ceramic network (PICN) composites are an increasingly popular dental restorative material that offer mechanical biocompatibility with human enamel. This study aimed to develop a novel PICN composite as a computer-aided design and computer-aided manufacturing (CAD/CAM) block for dental applications. Several PICN composites were prepared under varying conditions via the sintering of a green body prepared from a silica-containing precursor solution, followed by resin infiltration. The flexural strength of the PICN composite block (107.8–153.7 MPa) was similar to a commercial resin-based composite, while the Vickers hardness (204.8–299.2) and flexural modulus (13.0–22.2 GPa) were similar to human enamel and dentin, respectively. The shear bond strength and surface free energy of the composite were higher than those of the commercial resin composites. Scanning electron microscopy and energy dispersive X-ray spectroscopic analysis revealed that the microstructure of the composite consisted of a nanosized silica skeleton and infiltrated resin. The PICN nanocomposite block was successfully used to fabricate a dental crown and core via the CAD/CAM milling process.
Collapse
|
27
|
Ruggiero MM, Soares Gomes R, Pedroso Bergamo ET, Freitas MIM, Bonfante EA, Del Bel Cury AA. Resin-matrix ceramics for occlusal veneers: Effect of thickness on reliability and stress distribution. Dent Mater 2020; 37:e131-e139. [PMID: 33276957 DOI: 10.1016/j.dental.2020.11.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 07/31/2020] [Accepted: 11/02/2020] [Indexed: 11/16/2022]
Abstract
OBJECTIVE To evaluate the influence of resin-matrix ceramic material and thickness on reliability and stress distribution of occlusal veneers (OV). METHODS One hundred and twenty-six OV of a mandibular first molar were milled using a CAD/CAM system and allocated according to materials (resin nanoceramic (RNC) or polymer-infiltrated ceramic network (PICN)) and thicknesses (0.5, 1.0 and 1.5 mm), totaling six groups (RNC0.5, RNC1, RNC1.5, PICN0.5, PICN1, and PICN1.5). Step-stress accelerated-life testing was performed (n = 21/group) with the load applied at the distobuccal cusp tip of the occlusal veneer until failure or suspension. The use level probability Weibull curves and reliability were calculated and plotted (90% CI). Finite element analysis evaluated the stress distribution according to maximum principal stress (σmax) on the restoration and maximum shear stress (τmax) on the cement layer. RESULTS There was no difference in the probability of survival for the estimated missions among the groups, except at 600 N in which the results were significantly lower to PICN1.5 (6%) compared to RNC1 (55%) and RNC1.5 (60%). The σmax values were higher for PICN (31.85-48.63 MPa) than RNC (30.78-33.09 MPa) in the same thicknesses. In addition, 0.5 mm groups concentrated more stress in the restoration (33.09-48.63 MPa) than 1.0 mm (31.11-35.36 MPa) and 1.5 mm (30.78-31.85 MPa) groups in the same material. SIGNIFICANCE Both resin-matrix ceramic materials seem up-and-coming restorative systems for occlusal veneers irrespective of the thicknesses as a consequence of the high reliability.
Collapse
Affiliation(s)
- Mirelle Maria Ruggiero
- Department of Prosthodontics and Periodontology, University of Campinas - Piracicaba Dental School, Limeira Avenue, 901, Piracicaba, SP, 13414-903, Brazil
| | - Rafael Soares Gomes
- Department of Prosthodontics and Periodontology, University of Campinas - Piracicaba Dental School, Limeira Avenue, 901, Piracicaba, SP, 13414-903, Brazil
| | - Edmara Tatiely Pedroso Bergamo
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Dr. Octávio Pinheiro Brisolla Avenue, 9-75, Bauru, SP, 17012-901, Brazil
| | - Mariana Itaborai Moreira Freitas
- Department of Prosthodontics and Periodontology, University of Campinas - Piracicaba Dental School, Limeira Avenue, 901, Piracicaba, SP, 13414-903, Brazil
| | - Estevam Augusto Bonfante
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Dr. Octávio Pinheiro Brisolla Avenue, 9-75, Bauru, SP, 17012-901, Brazil
| | - Altair Antoninha Del Bel Cury
- Department of Prosthodontics and Periodontology, University of Campinas - Piracicaba Dental School, Limeira Avenue, 901, Piracicaba, SP, 13414-903, Brazil.
| |
Collapse
|
28
|
Dal Piva AMDO, Tribst JPM, Benalcázar Jalkh EB, Anami LC, Bonfante EA, Bottino MA. Minimal tooth preparation for posterior monolithic ceramic crowns: Effect on the mechanical behavior, reliability and translucency. Dent Mater 2020; 37:e140-e150. [PMID: 33246664 DOI: 10.1016/j.dental.2020.11.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 08/10/2020] [Accepted: 11/02/2020] [Indexed: 11/29/2022]
Abstract
OBJECTIVE Despite the increased use of monolithic crowns, their performance has yet to be determined when the minimal tooth preparation (MTP) principle is considered. The goal of this study was to evaluate the effect of MTP on the mechanical behavior, reliability and translucency of posterior monolithic ceramic crowns. METHODS Dentin analogues were machined using two preparation designs (0.5 or 1 mm reduction) to receive first molar crowns in order to evaluate the monolithic crown performance. Next, 126 crowns were divided (21/g) according to the material (High translucent zirconia - YZHT, Zirconia reinforced lithium silicate - ZLS and Hybrid ceramic - HC) and thickness (0.5 or 1 mm). Tensile stress concentration was calculated using the finite element method. The crowns were adhesivelly cemented and step stress fatigued to calculate reliability for missions at 600 and 1000 N. Translucency was analyzed in 10 discs of each material and thickness. RESULTS Higher stress concentration was found in thinner crowns and those with higher elastic modulus. YZHT crowns were suspended when fatigue reached 1500 N load, thus 1-parameter Weibull was used to analyze the data. Reliability was only affected by thickness at 1000 N. ZLS.5 showed lower survival than HC.5, which was similar to the groups that presented 100% survival. YZHT showed the highest strength and data scattering. ZLS1 (22.3 ± 1.4) presented higher translucency than HC1 (19.2 ± 0.6) and YZHT1 (12.0 ± 2.9), whereas ZLS.5 and HC.5 were similar to each other (26.5 ± 2.3, 26.7 ± 2.2) and superior to YZHT.5 (12.7 ± 1.2). SIGNIFICANCE HC.5 combined high reliability and translucency with low stress concentration, yielding better crown performance and tooth preservation.
Collapse
Affiliation(s)
- Amanda Maria de Oliveira Dal Piva
- PhD Graduate Program in Restorative Dentistry, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, nº 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil.
| | - João Paulo Mendes Tribst
- PhD Graduate Program in Restorative Dentistry, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, nº 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil.
| | - Ernesto Byron Benalcázar Jalkh
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry. Alameda Dr. Octávio Pinheiro Brisolla, 9-75, 17012-901, Bauru, SP, Brazil.
| | - Lilian Costa Anami
- PhD Graduate Program in Restorative Dentistry, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, nº 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil.
| | - Estevam Augusto Bonfante
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry. Alameda Dr. Octávio Pinheiro Brisolla, 9-75, 17012-901, Bauru, SP, Brazil.
| | - Marco Antonio Bottino
- PhD Graduate Program in Restorative Dentistry, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, nº 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil.
| |
Collapse
|
29
|
Kilinc H, Sanal FA, Turgut S. Shear bond strengths of aged and non-aged CAD/CAM materials after different surface treatments. J Adv Prosthodont 2020; 12:273-282. [PMID: 33149848 PMCID: PMC7604239 DOI: 10.4047/jap.2020.12.5.273] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 06/15/2020] [Accepted: 07/07/2020] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To assess shear bond strengths (SBS) of resin composites on aged and non-aged prosthetic materials with various surface treatments. MATERIALS AND METHODS Cerasmart (CE), Vita Enamic (VE), Vita Mark II (VM), and IPS e.max CAD (EC) blocks were sliced, and rectangular-shaped specimens (14 × 12 × 1.5 mm; N = 352) were obtained. Half of the specimens were aged (5000 thermal cycles) for each material. Non-aged and aged specimens were divided into 4 groups according to the surface treatments (control, air abrasion, etching, and laser irradiation; n = 11) and processed for scanning electron microscopy (SEM). The repair procedure was performed after the surface treatments. SBS values and failure types were determined. Obtained data were statistically analyzed (P≤.05). RESULTS The material type, surface treatment type, and their interactions were found significant with regard to SBS (P<.001). Aging also had a significant effect on prosthetic material-resin composite bonding (P<.001). SBS values of non-aged specimens ranged from 12.16 to 17.91 MPa, while SBS values of aged specimens ranged from 9.46 to 15.61 MPa. Non-aged VM in combination with acid etching presented the highest score while the control group of aged CE showed the lowest. CONCLUSION Etching was more effective in achieving durable SBS for VM and EC. Laser irradiation could be considered as an alternative surface treatment method to air abrasion for all tested materials. Aging had significant effect on SBS values generated between tested materials and resin composite.
Collapse
Affiliation(s)
- Hamiyet Kilinc
- Department of Prosthodontics, Faculty of Dentistry, Bolu Abant Izzet Baysal University, Bolu, Turkey
| | - Fatma Ayse Sanal
- Department of Prosthodontics, Faculty of Dentistry, Bolu Abant Izzet Baysal University, Bolu, Turkey
| | - Sedanur Turgut
- Department of Prosthodontics, Faculty of Dentistry, Karadeniz Technical University, Trabzon, Turkey
| |
Collapse
|
30
|
Velho HC, Dapieve KS, Rocha Pereira GK, Fraga S, Valandro LF, Venturini AB. Accelerated loading frequency does not influence the fatigue behavior of polymer infiltrated ceramic network or lithium disilicate glass-ceramic restorations. J Mech Behav Biomed Mater 2020; 110:103905. [DOI: 10.1016/j.jmbbm.2020.103905] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 05/28/2020] [Accepted: 05/31/2020] [Indexed: 11/30/2022]
|
31
|
Yamaguchi S, Katsumoto Y, Hayashi K, Aoki M, Kunikata M, Nakase Y, Lee C, Imazato S. Fracture origin and crack propagation of CAD/CAM composite crowns by combining of in vitro and in silico approaches. J Mech Behav Biomed Mater 2020; 112:104083. [PMID: 32979609 DOI: 10.1016/j.jmbbm.2020.104083] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 09/04/2020] [Accepted: 09/07/2020] [Indexed: 12/18/2022]
Abstract
PURPOSE Fractographic analysis has been used to investigate the fracture behavior of Computer-aided design/computer-aided manufacturing (CAD/CAM) composite crowns by subjecting them to compression tests. However, it is difficult to investigate details of the fracture, including its initiation and propagation, using in vitro tests. The aim of this study was to determine the fracture origins and the order of crack initiation of CAD/CAM composite crowns using in silico nonlinear dynamic finite element analysis (FEA). MATERIAL AND METHODS The following materials were used: Cerasmart (CS), Katana Avencia Block (KA), and Shofu Block HC (HC) as CAD/CAM crowns, Panavia SA Cement Plus (SA) as a luting material, and Clearfil DC Core Plus (DC) as an abutment. The elastic moduli and fracture strain of each material were obtained from the stress-strain curve of in vitro three-point bending tests. The fracture origins and order of crack initiation of the materials were determined by in silico nonlinear dynamic compression analysis. Load-displacement curves were statistically compared with the results of the in vitro compression tests (Pearson's correlation test, α = 0.05). RESULTS The nonlinear dynamic FEA demonstrated that crack initiation was primarily observed near the lingual side of the CAD/CAM crowns and immediately propagated to the central fossa. The models were fractured following the in vitro fracture strains, showing the same order for the products tested (CS/KA/HC, SA, and DC). Load-displacement curves with the use of CS, KA, and HC were significantly correlated to the corresponding in vitro compression tests results (CS: r = 0.985, p < 0.05, KA: r = 0.987, p < 0.05, and HC: r = 0.997, p < 0.05). CONCLUSIONS The in silico model established in this study clarified the crack initiation of the CAD/CAM composite crowns and the order of crack initiation among the investigated products, suggesting that the present approach is useful for analyzing the fracture behavior of CAD/CAM composite crowns in detail.
Collapse
Affiliation(s)
- Satoshi Yamaguchi
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan.
| | - Yu Katsumoto
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Kimiko Hayashi
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Maika Aoki
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Miwa Kunikata
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Yutaro Nakase
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan; Department of Pediatric Dentistry, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Chunwoo Lee
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Satoshi Imazato
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan; Department of Advanced Functional Biomaterials Science, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| |
Collapse
|
32
|
High load frequency at 20Hz: Its effects on the fatigue behavior of a leucite-reinforced glass-ceramic. J Mech Behav Biomed Mater 2020; 107:103769. [DOI: 10.1016/j.jmbbm.2020.103769] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 03/30/2020] [Accepted: 03/31/2020] [Indexed: 12/27/2022]
|
33
|
Ilie N, Furtos G. A Comparative Study of Light Transmission by Various Dental Restorative Materials and the Tooth Structure. Oper Dent 2020; 45:442-452. [PMID: 32053462 DOI: 10.2341/19-037-l] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/29/2019] [Indexed: 11/23/2022]
Abstract
CLINICAL RELEVANCE Light transmission through dental materials and tooth structure has direct clinical implication on such factors as selecting an appropriate curing technique during a restorative process. SUMMARY
Collapse
|
34
|
Influence of Occlusal Thickness and Radicular Extension on the Fracture Resistance of Premolar Endocrowns from Different All-Ceramic Materials. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10082696] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Endocrowns are primarily recommended in a molar region with a standardized preparation design. The aim of the study was to evaluate the effect of different occlusal preparation depths, pulp chamber-radicular extension, and all-ceramic materials on the fracture resistance of premolar endocrowns. Ninety human premolar teeth were root canal treated, randomly divided into three main groups according to all-ceramic material used for fabrication as Lithium Disilicate (LD) ceramic, Polymer infiltrated ceramic (PIC) and High translucency zirconia (HTZ). They were further subdivided into three subgroups (n = 10) according to preparation design of 2 mm occlusal reduction, 4.5 mm occlusal reduction and 4.5 mm occlusal reduction with 2 mm radicular extension. The endocrowns from respective restorative materials were fabricated, surface conditioned, and cemented with self-adhesive resin cement. All samples were thermocycled for 5000 cycles and subjected to compressive static load at 45° angluation with the cross-head speed of 0.5 mm/minute until the fracture. The mean fracture resistance of LD ceramic at 2 mm, 4.5 mm thickness and radicular extension was 62.55 MPa, 45.80 MPa, 74.27 MPa respectively. The corresponding values for the PIC and HTZ ceramics were 26.30 MPa, 21.65 MPa, 25.66 Mpa and 23.47 MPa, 27.30 MPa, 37.29 MPa respectively. The LD ceramic and greater extension inside the pulp chamber had higher fracture resistance.
Collapse
|
35
|
Sliding contact wear and subsurface damage of CAD/CAM materials against zirconia. Dent Mater 2020; 36:387-401. [PMID: 32007314 DOI: 10.1016/j.dental.2020.01.015] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2019] [Revised: 12/11/2019] [Accepted: 01/14/2020] [Indexed: 11/24/2022]
Abstract
OBJECTIVE Most previous work conducted on the wear behavior of dental materials has focused on wear rates and surface damage. There is, however, scarce information regarding the subsurface damage arising from sliding contact fatigue. The aim of this study was to elucidate the wear mechanisms and the subsurface damage generated during sliding contact fatigue in 5 contemporary CAD/CAM materials against a zirconia indenter. METHODS Forty discs (Ø12mm, 1.55mm thick) were cut out of IPS e.max CAD (e.CAD), Suprinity PC (SUP), Enamic (ENA), Vitablocs Mark II (VMII) and Lava Ultimate (LU) blocks and mirror polished. After cementation onto a dentin-like composite, off-axis mouth-motion cycling was conducted with a spherical zirconia indenter (r=3.18mm) in water (200N load, 2Hz frequency) for 5 different cycling periods (102, 103, 104, 105, 106 cycles, n=8). Analysis of the wear scars was conducted using light-microscopy, scanning-electron-microscopy and optical profilometry. Subsurface damage was assessed using sagittal and transverse sections of the samples. RESULTS Fatigue wear mechanisms predominated in glassy materials (e.CAD, SUP, VMII), accompanied by extensive subsurface damage, whereas abrasive wear mechanisms were responsible for the large wear craters in the resin composite (LU) with an absolute absence of subsurface fracture. A combination of both mechanisms was observed in the polymer-infiltrated reinforced-glass (ENA), displaying large wear craters and severe subsurface damage. SIGNIFICANCE Well-controlled laboratory simulation can identify wear and subsurface damage susceptibility of various classes of restorative materials. Both wear and subsurface fracture are determining factors for the long-term success of restorations.
Collapse
|
36
|
Bergamo ET, Bordin D, Ramalho IS, Lopes AC, Gomes RS, Kaizer M, Witek L, Bonfante EA, Coelho PG, Del Bel Cury AA. Zirconia-reinforced lithium silicate crowns: Effect of thickness on survival and failure mode. Dent Mater 2019; 35:1007-1016. [DOI: 10.1016/j.dental.2019.04.007] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2018] [Revised: 02/12/2019] [Accepted: 04/12/2019] [Indexed: 10/26/2022]
|
37
|
Preparation of silica–poly(methyl methacrylate) composite with a nanoscale dual-network structure and hardness comparable to human enamel. Dent Mater 2019; 35:893-899. [DOI: 10.1016/j.dental.2019.03.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 02/17/2019] [Accepted: 03/15/2019] [Indexed: 11/21/2022]
|
38
|
Kaizer MR, Moraes RR, Cava SS, Zhang Y. The progressive wear and abrasiveness of novel graded glass/zirconia materials relative to their dental ceramic counterparts. Dent Mater 2019; 35:763-771. [PMID: 30827797 PMCID: PMC6462421 DOI: 10.1016/j.dental.2019.02.022] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Accepted: 02/13/2019] [Indexed: 12/14/2022]
Abstract
OBJECTIVE To investigate the wear behavior of novel graded glass/zirconia materials and their abrasiveness to the antagonist relative to homogeneous zirconias (polished or glazed) and a glass-ceramic. METHODS Graded glass/zirconia specimens were prepared by sintering with concurrent glass-infiltration of pre-sintered zirconia (3Y-TZP) with a polished or as-machined surface. Monolithic zirconia samples were sintered and their surfaces were polished or glazed (as-machined). Glass-ceramic samples were obtained and the surface polished. All specimens were subjected to chewing simulations with a steatite antagonist (r = 3 mm) and a cyclic load of 50 N. Quantitative measurements of wear and roughness were performed on ceramics and antagonists for prescribed number of cycles. Damage sustained in ceramics and antagonists was analyzed by SEM. RESULTS The polished zirconia presented little to no variation in wear depth (2 μm) and roughness (0.06 μm). Graded and glazed zirconia experienced a rapid increase in wear depth while the superficial glass layer was present (until 1000 cycles), but showed little variations afterwards - at 450k cycles ∼15 μm for graded and 78 μm for glazed zirconia. The glass-ceramic presented the greatest wear depth (463 μm) and roughness (1.48 μm). Polished zirconia, polished graded zirconia and glazed zirconia yielded significantly lower volumetric wear (∼3 mm3) of the antagonist than as-machined graded zirconia and glass-ceramic (∼5 mm3). SIGNIFICANCE Polished graded zirconia and polished zirconia presented little wear and roughness, as well as yielded reduced antagonist wear. Glassy materials are both more susceptible to wear and more abrasive to the antagonist relative to zirconia.
Collapse
Affiliation(s)
- Marina R Kaizer
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY 10010, USA; Graduate Program in Dentistry, Positivo University, Curitiba, PR 81280-330, Brazil
| | - Rafael R Moraes
- Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, RS 96015-560, Brazil
| | - Sergio S Cava
- Graduate Program in Materials Science and Engineering, Federal University of Pelotas, Pelotas, RS 96010-560, Brazil
| | - Yu Zhang
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY 10010, USA.
| |
Collapse
|
39
|
Maeder M, Pasic P, Ender A, Özcan M, Benic GI, Ioannidis A. Load-bearing capacities of ultra-thin occlusal veneers bonded to dentin. J Mech Behav Biomed Mater 2019; 95:165-171. [PMID: 31009900 DOI: 10.1016/j.jmbbm.2019.04.006] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Revised: 04/08/2019] [Accepted: 04/09/2019] [Indexed: 10/27/2022]
Abstract
OBJECTIVES To test whether the load-bearing capacity of occlusal veneers made of ceramic or hybrid materials bonded to dentin does differ from those of porcelain-fused-to metal or lithium disilicate glass ceramic crowns. MATERIAL AND METHODS In 80 human molars, occlusal tooth substance was removed so that the defects extended into dentin, simulating defects caused by attrition/erosion. Restorations at a standardized thickness of either 0.5 mm or 1.0 mm were digitally designed. For both thicknesses, 4 test groups (n = 10 per group) were defined, each including a different restorative material: "0.5-ZIR": 0.5 mm thick zirconia (Vita YZ HT); "1.0-ZIR": 1.0 mm thick zirconia (Vita YZ HT); "0.5-LDC": 0.5 mm thick lithium disilicate ceramic (IPS e.max Press); "1.0-LDC": 1.0 mm thick lithium disilicate ceramic (IPS e.max Press); "0.5-HYC": 0.5 mm thick PICN (Vita Enamic); "1.0-HYC": 1.0 mm thick PICN (Vita Enamic); "0.5-COC": 0.5 mm thick tooth shaded resin composite (Lava Ultimate) and "1.0-COC": 1.0 mm thick tooth shaded resin composite (Lava Ultimate). Consecutively, the specimens were thermo-mechanically aged and then loaded until fracture. The load-bearing capacities (Fmax) between the groups were statistically compared using the Kruskal-Wallis test (p < 0.05) and pairwise group comparison applying the Dunn's method. In addition, the results were compared to those of conventional lithium-disilicate ceramic crowns ("CLD") and to porcelain-fused to metal crowns ("PFM"). RESULTS The median Finitial values for the 0.5 mm thin restorations were 1'350 N for 0.5-ZIR, 850 N for 0.5-LDC, 1'100 N for 0.5-HYC and 1'950 N for 0.5-COC. With CLD as the control, a significant difference was found between the groups 0.5-COC and 0.5-LDC (KW: p = 0.0124). With PFM as the control, the comparisons between PFM and 0.5-LDC as well as between 0.5-COC and 0.5-LDC were significant (KW: p = 0.0026). Median Fmax values of 2'493 N in the group 0.5-ZIR, 1'165 in the group 0.5-LDC, 2'275 N in the group 0.5-HYC and 2'265 N in the group 0.5-COC were found. The medians of the Finitial values for the 1.0 thick restorations amounted of 2'100 N in 1.0-ZIR, 1'750 N in 1.0-LDC, 2'000 N in 1.0-HYC and 2'300 N in 1.0-COC. Testing the multiple comparisons with Dunn's method no significant differences were found (p > 0.05). The median Fmax values of the 1.0 mm thick restorations were: 2'489 N in the group 1.0-ZIR, 1'864 N in the group 1.0-LDC, 2'485 N in the group 1.0-HYC and 2'479 N in the group 1.0-COC. With CLD as the control group, a significant difference between zirconia and lithium-disilicate was found for the 0.5 (p = 0.0017) and 1.0 mm (p = 0.0320) thick specimens. Comparing the 0.5 mm thick specimens with CLD as the control, a significant difference was found between 0.5-HYC and 0.5-LDC (p = 0.0017). With PFM as the control, the comparison of lithium disilicate and zirconia was statistically significant for both thicknesses (p = 0.0009 for the 0.5 mm thick specimens; p = 0.0074 for the 1.0 mm thick specimens). In addition, with PFM as control group, significant differences were seen between 0.5-LDC and all other groups with restorations in 0.5 mm thickness (p = 0.0017). CONCLUSIONS Regarding their maximum load-bearing capacity, minimally invasive occlusal veneers made of ceramic, hybrid materials or polymeric materials can be applied to correct occlusal tooth wear with exposed dentin and thus replace conventional crown restorations in cases of normally expected intraoral bite forces.
Collapse
Affiliation(s)
- Mila Maeder
- Doctoral Student at the Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Switzerland
| | - Pavla Pasic
- Doctoral Student at the Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Switzerland
| | - Adreas Ender
- Clinic of Preventive Dentistry, Periodontology and Cariology, Center of Dental Medicine, University of Zurich, Switzerland
| | - Mutlu Özcan
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Switzerland
| | - Goran I Benic
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Switzerland
| | - Alexis Ioannidis
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Switzerland.
| |
Collapse
|
40
|
Kaizer MR, Bano S, Borba M, Garg V, Dos Santos MBF, Zhang Y. Wear Behavior of Graded Glass/Zirconia Crowns and Their Antagonists. J Dent Res 2019; 98:437-442. [PMID: 30744472 DOI: 10.1177/0022034518820918] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Monolithic zirconia crowns have become very popular; their surface finish is considered a key factor for restoration longevity. While polishing has shown excellent results in vivo, the surface glass infiltration of zirconia may offer superior damage resistance and aesthetic advantages by using tooth-colored glasses. Thus, the purpose of this study is to evaluate the efficacy of polishing and glass infiltration on the wear behavior of monolithic zirconia crowns. The wear behavior of intact natural molar teeth was investigated as a reference. Zirconia crowns were divided into 3 groups: PolZ-sintered then polished; PolGZ-polished in the presintered state and then glass infiltrated and sintered; NoPolGZ-as machined, glass infiltrated and sintered. Crowns were adhesively bonded to a dentin-like abutment. Zirconia crowns and molar teeth ( n = 15) were subjected to contact-slide-liftoff cyclic loading (200 N, 1.25 million cycles) with a steatite sphere ( r = 3 mm) as an antagonist in water. Surface and subsurface damages were investigated with optical and scanning electron microscopies. Wear depth and volume loss were determined with micro-computed tomography. PolGZ and NoPolGZ crowns exhibited shallow wear scars, where material loss remained within the glass/zirconia layer with no visible cracks. Meanwhile, PolZ crowns presented no visible wear damage. Volume loss (mm3) in the steatite antagonist was as follows (mean ± SD): PolZ = 0.022 ± 0.007, PolGZ = 0.011 ± 0.004, and NoPolGZ = 0.014 ± 0.006. Molar teeth yielded no measurable wear on the antagonist, while the wear scar on the teeth was greater than that on zirconia crowns, ranging from 0.07 to 0.35 mm3. The combination of polishing and glass infiltration on the occlusal surface of monolithic zirconia crowns yielded reduced wear on both crown and antagonist.
Collapse
Affiliation(s)
- M R Kaizer
- 1 Department of Biomaterials and Biomimetics, College of Dentistry, New York University, New York, NY, USA
| | - S Bano
- 1 Department of Biomaterials and Biomimetics, College of Dentistry, New York University, New York, NY, USA
| | - M Borba
- 1 Department of Biomaterials and Biomimetics, College of Dentistry, New York University, New York, NY, USA.,2 Graduate Program in Dentistry, University of Passo Fundo, Passo Fundo, Brazil
| | - V Garg
- 1 Department of Biomaterials and Biomimetics, College of Dentistry, New York University, New York, NY, USA
| | - M B F Dos Santos
- 3 Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, Brazil
| | - Y Zhang
- 1 Department of Biomaterials and Biomimetics, College of Dentistry, New York University, New York, NY, USA
| |
Collapse
|
41
|
Yadav S, Gangwar S. A critical evaluation of tribological interaction for restorative materials in dentistry. INT J POLYM MATER PO 2018. [DOI: 10.1080/00914037.2018.1525544] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Sukriti Yadav
- Department of Mechanical Engineering, Madan Mohan Malaviya University of Technology, Gorakhpur, India
| | - Swati Gangwar
- Department of Mechanical Engineering, Madan Mohan Malaviya University of Technology, Gorakhpur, India
| |
Collapse
|
42
|
Tribst JPM, Dal Piva AMDO, Penteado MM, Borges ALS, Bottino MA. Influence of ceramic material, thickness of restoration and cement layer on stress distribution of occlusal veneers. Braz Oral Res 2018; 32:e118. [DOI: 10.1590/1807-3107bor-2018.vol32.0118] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Accepted: 10/17/2018] [Indexed: 11/22/2022] Open
|
43
|
Hao Z, Ma Y, Liu W, Meng Y, Nakamura K, Shen J, Wang H. Influence of low-temperature degradation on the wear characteristics of zirconia against polymer-infiltrated ceramic-network material. J Prosthet Dent 2018; 120:596-602. [DOI: 10.1016/j.prosdent.2017.12.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2017] [Revised: 12/14/2017] [Accepted: 12/14/2017] [Indexed: 10/17/2022]
|
44
|
Fatigue behavior and crack initiation of CAD/CAM resin composite molar crowns. Dent Mater 2018; 34:1578-1584. [DOI: 10.1016/j.dental.2018.07.002] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Revised: 06/12/2018] [Accepted: 07/09/2018] [Indexed: 11/21/2022]
|
45
|
CAD-FEA modeling and analysis of different full crown monolithic restorations. Dent Mater 2018; 34:1342-1350. [DOI: 10.1016/j.dental.2018.06.024] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Revised: 05/09/2018] [Accepted: 06/07/2018] [Indexed: 11/21/2022]
|
46
|
Kruzic JJ, Arsecularatne JA, Tanaka CB, Hoffman MJ, Cesar PF. Recent advances in understanding the fatigue and wear behavior of dental composites and ceramics. J Mech Behav Biomed Mater 2018; 88:504-533. [PMID: 30223214 DOI: 10.1016/j.jmbbm.2018.08.008] [Citation(s) in RCA: 75] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Revised: 08/06/2018] [Accepted: 08/08/2018] [Indexed: 12/30/2022]
Abstract
Dental composite and ceramic restorative materials are designed to closely mimic the aesthetics and function of natural tooth tissue, and their longevity in the oral environment depends to a large degree on their fatigue and wear properties. The purpose of this review is to highlight some recent advances in our understanding of fatigue and wear mechanisms, and how they contribute to restoration failures in the complex oral environment. Overall, fatigue and wear processes are found to be closely related, with wear of dental ceramic occlusal surfaces providing initiation sites for fatigue failures, and subsurface fatigue crack propagation driving key wear mechanisms for composites, ceramics, and enamel. Furthermore, both fatigue and wear of composite restorations may be important in enabling secondary caries formation, which is the leading cause of composite restoration failures. Overall, developing a mechanistic description of fatigue, wear, and secondary caries formation, along with understanding the interconnectivity of all three processes, are together seen as essential keys to successfully using in vitro studies to predict in vivo outcomes and develop improved dental restorative materials.
Collapse
Affiliation(s)
- Jamie J Kruzic
- School of Mechanical and Manufacturing Engineering, UNSW Sydney, Sydney, NSW 2052, Australia.
| | | | - Carina B Tanaka
- School of Mechanical and Manufacturing Engineering, UNSW Sydney, Sydney, NSW 2052, Australia
| | - Mark J Hoffman
- School of Mechanical and Manufacturing Engineering, UNSW Sydney, Sydney, NSW 2052, Australia; School of Materials Science and Engineering, UNSW Sydney, Sydney, NSW 2052, Australia
| | - Paulo F Cesar
- Department of Biomaterials and Oral Biology, School of Dentistry, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
47
|
Blackburn C, Rask H, Awada A. Mechanical properties of resin-ceramic CAD-CAM materials after accelerated aging. J Prosthet Dent 2018; 119:954-958. [DOI: 10.1016/j.prosdent.2017.08.016] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2017] [Revised: 08/30/2017] [Accepted: 08/30/2017] [Indexed: 10/18/2022]
|
48
|
Baumgart P, Kirsten H, Haak R, Olms C. Biomechanical properties of polymer-infiltrated ceramic crowns on one-piece zirconia implants after long-term chewing simulation. Int J Implant Dent 2018; 4:16. [PMID: 29790033 PMCID: PMC5964049 DOI: 10.1186/s40729-018-0127-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2017] [Accepted: 03/20/2018] [Indexed: 12/31/2022] Open
Abstract
Background Implant and superstructure provide a complex system, which has to withstand oral conditions. Concerning the brittleness of many ceramics, fractures are a greatly feared issue. Therefore, polymer-infiltrated ceramic networks (PICNs) were developed. Because of its high elastic modulus, the PICN crown on a one-piece zirconia implant might absorb forces to prevent the system from fracturing in order to sustain oral forces. Recommendations for the material of superstructure on zirconia implants are lacking, and only one study investigates PICN crowns on these types of implants. Accordingly, this study aimed to examine PICN crowns on one-piece zirconia implants regarding bond strength and surface wear after long-term chewing simulation (CS). Methods Twenty-five hybrid ceramic crowns (Vita Enamic, Vita Zahnfabrik) were produced using computer-aided design/computer-aided manufacturing (CAD/CAM) technology and adhesively bonded (RelyX™ Ultimate, 3M ESPE) to zirconia implants. Twenty of the specimens underwent simultaneous mechanical loading and thermocycling simulating a 5-year clinical situation (SD Mechatronik GmbH). Wear depth and wear volume, based on X-ray micro-computed tomography volume scans (Skyscan 1172-100-50, Bruker) before and after CS, were evaluated. All crowns were removed from the implants using a universal testing machine (Z010, Zwick GmbH&Co.KG). Subsequently, luting agent was light microscopically localized (Stemi 2000-C, Zeiss). With a scanning electron microscope (SEM, Phenom™ G2 pro, Phenom World), the area of abrasion was assessed. Results After CS, none of the tested crowns were fractured or loosened. The maximum vertical wear after CS was M = 0.31 ± 0.04 mm (mean ± standard deviation), and the surface wear was M = 0.74 ± 0.23 mm3. The pull-off tests revealed a 1.8 times higher bond strength of the control group compared to the experimental group (t(23) = 8.69, p < 0.001). Luting agent was mostly located in the crowns, not on the implants. The area of abrasion showed avulsion and a rough surface.
Conclusions PICN on one-piece zirconia implants showed high bond strength and high wear after CS.
Collapse
Affiliation(s)
- Pia Baumgart
- Department of Dental Prosthodontics and Materials Science, University of Leipzig, Liebigstraße 12, Haus 1, 04103, Leipzig, Germany
| | - Holger Kirsten
- Institute for Medical Informatics, Statistics, and Epidemiology (IMISE), Haertelstraße 16-18, 04107, Leipzig, Germany.,LIFE Research Center for Civilization Diseases, University of Leipzig, Philipp-Rosenthal-Straße 27, 04103, Leipzig, Germany
| | - Rainer Haak
- Department of Cariology, Endodontology and Periodontology, University of Leipzig, Liebigstraße 12, Haus 1, 04103, Leipzig, Germany
| | - Constanze Olms
- Department of Dental Prosthodontics and Materials Science, University of Leipzig, Liebigstraße 12, Haus 1, 04103, Leipzig, Germany.
| |
Collapse
|
49
|
Goryainova KE, Morokov ES, Retinskaja MV, Rusanov FS, Apresyan SV, Lebedenko IY. The Micromorphological Research of the Internal Structure of Chairside CAD/CAM Materials by the Method of Scanning Impulse Acoustic Microscopy (SIAM). Open Dent J 2018; 12:125-132. [PMID: 29492178 PMCID: PMC5814947 DOI: 10.2174/1874210601812010125] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Revised: 12/20/2017] [Accepted: 01/05/2018] [Indexed: 11/22/2022] Open
Abstract
Aim The aim of the present work was to compare the elastic properties and internal structure of 4 different CAD/CAM chairside materials, by the method of Scanning Impulse Acoustic Microscopy (SIAM). Methods Four chairside CAD/CAM materials with different structures from hybrid ceramic (VITA Enamic, VITA Zahnfabrik), feldspatic ceramic (VITABlocs Mark II, VITA Zahnfabrik), leucite glass-ceramic (IPS Empress CAD, Ivoclar Vivadent) and PMMA (Telio CAD, Ivoclar Vivadent) were examined by Scanning Impulse Acoustic Microscope (SIAM). Results The results of micromorphological research of CAD/CAM chairside materials using SIAM method showed differences between the internal structures of these materials. The internal structure of feldspatic and glass-ceramic samples revealed the presence of pores with different sizes, from 10 to 100 microns; the structure of polymer materials rendered some isolated defects, while in the structure of hybrid material, defects were not found. Conclusion Based on the results obtained from the present study, in cases of chairside production of dental crowns, it would be advisable to give preference to the blocks of hybrid ceramics. Such ceramics devoid of quite large porosity, glazing for CAD/CAM crowns made from leucite glass-ceramic and feldspatic ceramic may be an option. For these purposes, commercially available special muffle furnace for clinical and laboratory individualization and glazing of ceramic prostheses were provided. Further studies are needed to confirm the evidence emerging from the present research.
Collapse
Affiliation(s)
- Kristina E Goryainova
- The Department of Prosthetic Dentistry of Medical Faculty, The Peoples' Friendship University of Russia, 117198, Moscow, Russia
| | - Egor S Morokov
- The N.M. Emanuel Institute of Biochemical Physics RAS, IBCP RAS, 119334, Moscow, Russia.,Scientific and Technological Center of Unique Instrumentation RAS, IBCP RAS, 117342, Moscow, Russia
| | - Marina V Retinskaja
- The Department of Prosthetic Dentistry of Medical Faculty, The Peoples' Friendship University of Russia, 117198, Moscow, Russia.,Federal State Institution, Central Research Institute of Dental and Maxillofacial Surgery, Ministry of Health, Russian Federation, 119034, Moscow, Russia
| | - Fedor S Rusanov
- Federal State Institution, Central Research Institute of Dental and Maxillofacial Surgery, Ministry of Health, Russian Federation, 119034, Moscow, Russia
| | - Samvel V Apresyan
- The Department of Prosthetic Dentistry of Medical Faculty, The Peoples' Friendship University of Russia, 117198, Moscow, Russia
| | - Igor Yu Lebedenko
- The Department of Prosthetic Dentistry of Medical Faculty, The Peoples' Friendship University of Russia, 117198, Moscow, Russia.,Federal State Institution, Central Research Institute of Dental and Maxillofacial Surgery, Ministry of Health, Russian Federation, 119034, Moscow, Russia
| |
Collapse
|
50
|
Bankoğlu Güngör M, Karakoca Nemli S. Fracture resistance of CAD-CAM monolithic ceramic and veneered zirconia molar crowns after aging in a mastication simulator. J Prosthet Dent 2018. [DOI: 10.1016/j.prosdent.2017.05.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|