1
|
Momeni Abkharaki A, Ensafi AA. Fabrication of binary metal-organic frameworks of Ni-Mn@ZIFs(Co x·Zn 1-xO) decorated on CF/CuO nanowire for high-performance electrochemical pseudocapacitors. Sci Rep 2024; 14:13482. [PMID: 38866922 PMCID: PMC11169229 DOI: 10.1038/s41598-024-64307-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2024] [Accepted: 06/07/2024] [Indexed: 06/14/2024] Open
Abstract
Herein, metal-organic frameworks (MOFs) derived nanoflower-like based binary transition metal (Ni-Mn) are successfully fabricated by a simple synthesis method. The fabricated nanoflower-like structure displays a unique nanoflower-like architecture and internal porous channels constructed by MOF coated on CuO/CF/ZIFs (Cox·Zn1-xO) substrate, which is beneficial for the penetration of electrolyte and electron/ion transportation. The as-prepared CF/CuO/ZIFs (Cox·Zn1-xO)@BMOF(Ni-Mn) electrode materials present significant synergy among transition metal ions, contributing to enhanced electrochemical performances. The as-prepared CF/CuO/ZIFs (Cox·Zn1-xO)@BMOF(Ni-Mn) hybrid nanoflower-like display a high specific capacity of 1249.99 C g-1 at 1 A g-1 and the specific capacitance retention is about 91.74% after 5000 cycles. In addition, the as-assembled CF/CuO/ZIFs (Cox·Zn1-xO)@BMOF(Ni-Mn)//AC asymmetric supercapacitor (ASC) device exhibited a maximum energy density of 21.77 Wh·kg-1 at a power density of 799 W kg-1, and the capacity retention rate after 5000 charge and discharge cycles was 88.52%.
Collapse
Affiliation(s)
- Ali Momeni Abkharaki
- Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Iran
| | - Ali A Ensafi
- Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Iran.
- Department of Chemistry & Biochemistry, University of Arkansas, Fayetteville, AR, 72701, USA.
| |
Collapse
|
2
|
Dutta T, Noushin T, Tabassum S, Mishra SK. Road Map of Semiconductor Metal-Oxide-Based Sensors: A Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:6849. [PMID: 37571634 PMCID: PMC10422562 DOI: 10.3390/s23156849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 06/22/2023] [Accepted: 07/19/2023] [Indexed: 08/13/2023]
Abstract
Identifying disease biomarkers and detecting hazardous, explosive, flammable, and polluting gases and chemicals with extremely sensitive and selective sensor devices remains a challenging and time-consuming research challenge. Due to their exceptional characteristics, semiconducting metal oxides (SMOxs) have received a lot of attention in terms of the development of various types of sensors in recent years. The key performance indicators of SMOx-based sensors are their sensitivity, selectivity, recovery time, and steady response over time. SMOx-based sensors are discussed in this review based on their different properties. Surface properties of the functional material, such as its (nano)structure, morphology, and crystallinity, greatly influence sensor performance. A few examples of the complicated and poorly understood processes involved in SMOx sensing systems are adsorption and chemisorption, charge transfers, and oxygen migration. The future prospects of SMOx-based gas sensors, chemical sensors, and biological sensors are also discussed.
Collapse
Affiliation(s)
- Taposhree Dutta
- Department of Chemistry, IIEST Shibpur, Howrah 711103, West Bengal, India;
| | - Tanzila Noushin
- Department of Electrical and Computer Engineering, The University of Texas at Dallas, Richardson, TX 75080, USA;
| | - Shawana Tabassum
- Department of Electrical Engineering, The University of Texas at Tyler, Tyler, TX 75799, USA;
| | - Satyendra K. Mishra
- Danish Offshore Technology Center, Technical University of Denmark, 2800 Lyngby, Denmark
- SRCOM, Centre Technologic de Telecomunicacions de Catalunya, 08860 Castelldefels, Barcelona, Spain
| |
Collapse
|
3
|
Zhao Y, Jiang Y, Mo Y, Zhai Y, Liu J, Strzelecki AC, Guo X, Shan C. Boosting Electrochemical Catalysis and Nonenzymatic Sensing Toward Glucose by Single-Atom Pt Supported on Cu@CuO Core-Shell Nanowires. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2207240. [PMID: 36703531 DOI: 10.1002/smll.202207240] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 01/15/2023] [Indexed: 05/04/2023]
Abstract
It is critical to develop high-performance electrocatalyst for electrochemical nonenzymatic glucose sensing. In this work, a single-atom Pt supported on Cu@CuO core-shell nanowires (Pt1 /Cu@CuO NWs) for electrochemical nonenzymatic glucose sensor is designed. Pt1 /Cu@CuO NWs exhibit excellent electrocatalytic oxidation toward glucose with 70 mV lower onset potential (0.131 V) and 2.4 times higher response current than Cu NWs. Sensors fabricated using Pt1 /Cu@CuO NWs also show high sensitivity (852.163 µA mM-1 cm-2 ), low detection limit (3.6 µM), wide linear range (0.01-5.18 µM), excellent selectivity, and great long-term stability. The outstanding sensing performance of Pt1 /Cu@CuO NWs, investigated by experiments and density functional theory (DFT) calculations, is attributed to the synergistic effect between Pt single atoms and Cu@CuO core-shell nanowires that generates strong binding energy of glucose on the nanowires. The work provides a new pathway for exploring highly active SACs for electrochemical nonenzymatic glucose sensor.
Collapse
Affiliation(s)
- Yuanmeng Zhao
- Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, P. R. China
| | - Yunhao Jiang
- Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, P. R. China
| | - Yan Mo
- Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, P. R. China
| | - Yueming Zhai
- The Institute for Advanced Studies (IAS), Wuhan University, Wuhan, 430072, P. R. China
| | - Juejing Liu
- Department of Chemistry and Material Science and Engineering Program, Washington State University, Pullman, WA, 99164, USA
| | - Andrew C Strzelecki
- Department of Chemistry and Material Science and Engineering Program, Washington State University, Pullman, WA, 99164, USA
| | - Xiaofeng Guo
- Department of Chemistry and Material Science and Engineering Program, Washington State University, Pullman, WA, 99164, USA
| | - Changsheng Shan
- Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, P. R. China
| |
Collapse
|
4
|
Wei Q, Wu L, Zhu M, Wang Z, Huang ZH, Wang MX. Porous nitrogen-doped reduced graphene oxide-supported CuO@Cu 2O hybrid electrodes for highly sensitive enzyme-free glucose biosensor. iScience 2023; 26:106155. [PMID: 36879815 PMCID: PMC9984959 DOI: 10.1016/j.isci.2023.106155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 01/30/2023] [Accepted: 02/03/2023] [Indexed: 02/11/2023] Open
Abstract
Constructing high-performance enzyme-free biosensors for detecting glucose is essential to preliminary diabetes diagnosis. Here, copper oxide nanoparticles (CuO@Cu2O NPs) were anchored in porous nitrogen-doped reduced graphene oxide (PNrGO) to construct CuO@Cu2O/PNrGO/GCE hybrid electrode for sensitive detection of glucose. Benefiting from the remarkable synergistic effects between the multiple high activation sites of CuO@Cu2O NPs and the dramatic properties of PNrGO with excellent conductivity and large surface area with many accessible pores, the hybrid electrode possesses outstanding glucose sensing performance that is far superior to those of pristine CuO@Cu2O electrode. The as-fabricated enzyme-free glucose biosensor displays prominent glucose sensitivity of 2,906.07 μA mM-1 cm-2, extremely low limit of detection of 0.13 μM, and wide linear detection of 3 μM-6.772 mM. In addition, excellent reproducibility, favorable long-term stability, and distinguished selectivity are obtained in the glucose detection. Importantly, this study provides promising results for continuous improvement of non-enzyme sensing applications.
Collapse
Affiliation(s)
- Qing Wei
- Key Laboratory of Biomass-based Materials for Environment and Energy in Petroleum & Chemical Industries, School of Chemical and Environmental Engineering, Wuhan Institute of Technology, Wuhan 430205, China
| | - Ling Wu
- Hubei Province Key Laboratory of Coal Conversion and New Carbon Materials, School of Chemistry and Chemical Engineering, Wuhan University of Science and Technology, Wuhan 430081, China
| | - Meiwen Zhu
- Chongqing Academy of Metrology and Quality Inspection, Chongqing 401123, People's Republic of China
| | - Zhipeng Wang
- Institute of Advanced Materials, Jiangxi Normal University, 99 Ziyang Avenue, Nanchang 330022, China
| | - Zheng-Hong Huang
- Lab of Advanced Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China
| | - Ming-Xi Wang
- Key Laboratory of Biomass-based Materials for Environment and Energy in Petroleum & Chemical Industries, School of Chemical and Environmental Engineering, Wuhan Institute of Technology, Wuhan 430205, China
| |
Collapse
|
5
|
Wang C, Yang X, Zhu G, Wang T, Yu D, Lu Y, Yu H. One-step synthesis of copper-platinum nanoparticles modified electrode for non-enzymatic salivary glucose detection. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2022.130672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
6
|
Yang J, Chen H, Zhu C, Huang Z, Ou R, Gao S, Yang Z. A miniature CuO nanoarray sensor for noninvasive detection of trace salivary glucose. Anal Biochem 2022; 656:114857. [DOI: 10.1016/j.ab.2022.114857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 08/01/2022] [Accepted: 08/09/2022] [Indexed: 11/16/2022]
|
7
|
Metelka R, Vlasáková P, Smarzewska S, Guziejewski D, Vlček M, Sýs M. Screen-Printed Carbon Electrodes with Macroporous Copper Film for Enhanced Amperometric Sensing of Saccharides. SENSORS 2022; 22:s22093466. [PMID: 35591157 PMCID: PMC9104721 DOI: 10.3390/s22093466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 04/26/2022] [Accepted: 04/29/2022] [Indexed: 11/26/2022]
Abstract
A porous layer of copper was formed on the surface of screen-printed carbon electrodes via the colloidal crystal templating technique. An aqueous suspension of monodisperse polystyrene spheres of 500 nm particle diameter was drop-casted on the carbon tracks printed on the substrate made of alumina ceramic. After evaporation, the electrode was carefully dipped in copper plating solution for a certain time to achieve a sufficient penetration of solution within the polystyrene spheres. The metal was then electrodeposited galvanostatically over the self-assembled colloidal crystal. Finally, the polystyrene template was dissolved in toluene to expose the porous structure of copper deposit. The morphology of porous structures was investigated using scanning electron microscopy. Electroanalytical properties of porous copper film electrodes were evaluated in amperometric detection of selected saccharides, namely glucose, fructose, sucrose, and galactose. Using hydrodynamic amperometry in stirred alkaline solution, a current response at +0.6 V vs. Ag/AgCl was recorded after addition of the selected saccharide. These saccharides could be quantified in two linear ranges (0.2–1.0 μmol L−1 and 4.0–100 μmol L−1) with detection limits of 0.1 μmol L−1 glucose, 0.03 μmol L−1 fructose, and 0.05 μmol L−1 sucrose or galactose. In addition, analytical performance of porous copper electrodes was ascertained and compared to that of copper film screen-printed carbon electrodes, prepared ex-situ by the galvanostatic deposition of metal in the plating solution. After calculating the current densities with respect to the geometric area of working electrodes, the porous electrodes exhibited much higher sensitivity to changes in concentration of analytes, presumably due to the larger surface of the porous copper deposit. In the future, they could be incorporated in detectors of flow injection systems due to their long-term mechanical stability.
Collapse
Affiliation(s)
- Radovan Metelka
- Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10 Pardubice, Czech Republic; (R.M.); (P.V.)
| | - Pavlína Vlasáková
- Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10 Pardubice, Czech Republic; (R.M.); (P.V.)
| | - Sylwia Smarzewska
- Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, 12 Tamka Str., 91-403 Lodz, Poland; (S.S.); (D.G.)
| | - Dariusz Guziejewski
- Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, 12 Tamka Str., 91-403 Lodz, Poland; (S.S.); (D.G.)
| | - Milan Vlček
- Joint Laboratory of Solid State Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 84, 532 10 Pardubice, Czech Republic;
| | - Milan Sýs
- Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10 Pardubice, Czech Republic; (R.M.); (P.V.)
- Correspondence: ; Tel.: +420-466-037-034
| |
Collapse
|
8
|
Hu T, Wang D, Xu J, Chen K, Li X, Yi H, Ni Z. Glucose sensing on screen-printed electrochemical electrodes based on porous graphene aerogel @prussian blue. Biomed Microdevices 2022; 24:14. [PMID: 35218431 DOI: 10.1007/s10544-022-00614-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/01/2022] [Indexed: 12/24/2022]
Abstract
As one of the three major chronic diseases, diabetes often causes many complications, which can affect various parts of the body and even threaten the life of the patients. At present, the situation of diabetes in the world is quite serious. Accurate detection of blood glucose is very important for the diagnosis, treatment and medication of diabetes as well as the self-management of diabetic patients. In this paper, an electrochemical glucose biosensor was developed based on screen-printed electrode (SPE) modified with composite material of graphene aerogel (GA) and Prussian blue (PB) (denoted as GA@PB), which was fabricated via chemical reduction using L-ascorbic acid as a reducing agent through a freeze-drying process. Glucose was specifically captured by glucose oxidase (GOx) which were immobilized into the GA@PB by chitosan. The structure and performance of the sensor were characterized by scanning electron microscopy (SEM), Raman spectroscopy measurements, Fourier transform infrared spectrometer (FTIR), cyclic voltammetry (CV) and amperometric detection. The sensor exhibited a linear range of 0.5-6.0 mmol·L-1 with limit of detection (LOD) of 0.15 mmol·L-1, indicating that the combination of graphene aerogel and Prussian blue possess well conductivity and catalytic performance.
Collapse
Affiliation(s)
- Tao Hu
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Di Wang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Jian Xu
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Ke Chen
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Xiao Li
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| | - Hong Yi
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| | - Zhonghua Ni
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| |
Collapse
|
9
|
Current progress in organic–inorganic hetero-nano-interfaces based electrochemical biosensors for healthcare monitoring. Coord Chem Rev 2022. [DOI: 10.1016/j.ccr.2021.214282] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
10
|
Rapid Preparation of 3D Ultra-Thin CuO Nanosheets by Dielectric Barrier Discharge Microplasma for Non-Enzymatic Detection of Glucose. Catal Letters 2022. [DOI: 10.1007/s10562-022-03931-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
11
|
Tuan Le H, Thuy Nhi Le K, Phuong Ngo Q, Thanh Tran D, Hoon Kim N, Hee Lee J. Mo and Zn-Dual doped Cu xO nanocrystals confined High-Conductive Cu arrays as novel sensitive sensor for neurotransmitter detection. J Colloid Interface Sci 2022; 606:1031-1041. [PMID: 34487926 DOI: 10.1016/j.jcis.2021.08.106] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 08/10/2021] [Accepted: 08/15/2021] [Indexed: 11/27/2022]
Abstract
The development of sensitive and selective sensors using facile and low-cost methods for detecting neurotransmitter molecules is a critical factor in the health care system in regard to early diagnosis. In this research, an electrocatalyst derived from Mo,Zn dual-doped CuxO nanocrystals-based layer coating over one-dimensional copper nanowire arrays (Mo,Zn-CuxO/CuNWs) was successfully designed using a facile electrodeposition approach and used as an electrochemical sensor for non-enzymatic dopamine (DA) neurotransmitter detection. The synergistic effect caused by the dual-doping effect along with its excellent conductivity produced a large electroactive surface area and an improved hetero-charge transfer, thereby boosting DA sensing ability with a low limit detection of 0.32 µM, wide-range of detection (0.5 µM - 3.9 mM), long-term stability (5 weeks), and high selectivity in phosphate buffer solution (pH 7.4). Also, the sensor accurately determined DA in real blood serum-spiked solutions. The achieved results evidenced that the Mo,Zn-CuxO/CuNWs derived sensor is highly suitable for DA detection. Therefore, it also opens new windows for the development of low-cost, accurate, high-performance, and stable sensors for other neurotransmitter sensing for the purposes of better health care and early diagnosis.
Collapse
Affiliation(s)
- Huu Tuan Le
- Department of Nano Convergence Engineering, Jeonbuk National University, Jeonju, Jeonbuk 54896, Republic of Korea
| | - Kha Thuy Nhi Le
- Department of Nano Convergence Engineering, Jeonbuk National University, Jeonju, Jeonbuk 54896, Republic of Korea
| | - Quynh Phuong Ngo
- Department of Nano Convergence Engineering, Jeonbuk National University, Jeonju, Jeonbuk 54896, Republic of Korea
| | - Duy Thanh Tran
- Department of Nano Convergence Engineering, Jeonbuk National University, Jeonju, Jeonbuk 54896, Republic of Korea
| | - Nam Hoon Kim
- Department of Nano Convergence Engineering, Jeonbuk National University, Jeonju, Jeonbuk 54896, Republic of Korea.
| | - Joong Hee Lee
- Department of Nano Convergence Engineering, Jeonbuk National University, Jeonju, Jeonbuk 54896, Republic of Korea; Carbon Composite Research Center, Department of Polymer-Nano Science and Technology, Jeonbuk National University, Jeonju, Jeonbuk 54896, Republic of Korea.
| |
Collapse
|
12
|
Naikoo GA, Awan T, Salim H, Arshad F, Hassan IU, Pedram MZ, Ahmed W, Faruck HL, Aljabali AAA, Mishra V, Serrano‐Aroca Á, Goyal R, Negi P, Birkett M, Nasef MM, Charbe NB, Bakshi HA, Tambuwala MM. Fourth-generation glucose sensors composed of copper nanostructures for diabetes management: A critical review. Bioeng Transl Med 2022; 7:e10248. [PMID: 35111949 PMCID: PMC8780923 DOI: 10.1002/btm2.10248] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 08/10/2021] [Accepted: 08/13/2021] [Indexed: 01/31/2023] Open
Abstract
More than five decades have been invested in understanding glucose biosensors. Yet, this immensely versatile field has continued to gain attention from the scientific world to better understand and diagnose diabetes. However, such extensive work done to improve glucose sensing devices has still not yielded desirable results. Drawbacks like the necessity of the invasive finger-pricking step and the lack of optimization of diagnostic interventions still need to be considered to improve the testing process of diabetic patients. To upgrade the glucose-sensing devices and reduce the number of intermediary steps during glucose measurement, fourth-generation glucose sensors (FGGS) have been introduced. These sensors, made using robust electrocatalytic copper nanostructures, improve diagnostic efficiency and cost-effectiveness. This review aims to present the essential scientific progress in copper nanostructure-based FGGS in the past 10 years (2010 to present). After a short introduction, we presented the working principles of these sensors. We then highlighted the importance of copper nanostructures as advanced electrode materials to develop reliable real-time FGGS. Finally, we cover the advantages, shortcomings, and prospects for developing highly sensitive, stable, and specific FGGS.
Collapse
Affiliation(s)
- Gowhar A. Naikoo
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahOman
| | - Tasbiha Awan
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahOman
| | - Hiba Salim
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahOman
| | - Fareeha Arshad
- Department of BiochemistryAligarh Muslim UniversityAligarhIndia
| | | | - Mona Zamani Pedram
- Faculty of Mechanical Engineering—Energy DivisionK.N. Toosi University of TechnologyTehranIran
| | - Waqar Ahmed
- School of Mathematics and PhysicsCollege of Science, University of LincolnLincolnUK
| | | | - Alaa A. A. Aljabali
- Departmnt of Pharmaceutics and Pharmaceutical TechnologyYarmouk UniversityIrbidJordan
| | - Vijay Mishra
- School of Pharmaceutical SciencesLovely Professional UniversityPhagwaraPunjabIndia
| | - Ángel Serrano‐Aroca
- Biomaterials and Bioengineering LabTranslational Research Centre San Alberto Magno, Catholic University of Valencia San Vicente MártirValenciaSpain
| | - Rohit Goyal
- School of Pharmaceutical SciencesShoolini University of Biotechnology and Management SciencesSolanIndia
| | - Poonam Negi
- School of Pharmaceutical SciencesShoolini University of Biotechnology and Management SciencesSolanIndia
| | - Martin Birkett
- Department of Mechanical and Construction EngineeringNorthumbria UniversityNewcastle upon TyneUK
| | - Mohamed M. Nasef
- Department of PharmacySchool of Applied Science, University of HuddersfieldUK
| | - Nitin B. Charbe
- Department of Pharmaceutical SciencesRangel College of Pharmacy, Texas A&M UniversityKingsvilleTexasUSA
| | - Hamid A. Bakshi
- School of Pharmacy and Pharmaceutical ScienceUlster UniversityColeraineUK
| | | |
Collapse
|
13
|
|
14
|
Nonenzymatic electrochemical sensors via Cu native oxides (CuNOx) for sweat glucose monitoring. SENSING AND BIO-SENSING RESEARCH 2021. [DOI: 10.1016/j.sbsr.2021.100453] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
|
15
|
Scandurra A, Censabella M, Boscarino S, Condorelli GG, Grimaldi MG, Ruffino F. Fabrication of Cu(II) oxide-hydroxide nanostructures onto graphene paper by laser and thermal processes for sensitive nano-electrochemical sensing of glucose. NANOTECHNOLOGY 2021; 33:045501. [PMID: 34610585 DOI: 10.1088/1361-6528/ac2d0b] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Accepted: 10/05/2021] [Indexed: 06/13/2023]
Abstract
Glucose electrochemical sensors based on nanostructures of CuO/Cu(OH)2onto graphene paper were prepared by thermal (solid) and nanosecond pulsed laser (molten phase) dewetting of a CuO layer 6 nm thin deposited by sputtering. Dewetted systems, obtained without the use of any binder, act as array of nanoelectrodes. Solid state and molten phase dewetting produce nanostructures of copper oxide-hydroxide with different average size, shape and surface composition. Molten phase dewetting originates particles with size below 100 nm, while solid state dewetting produces particles with average size of about 200 nm. Moreover, molten phase dewetting produce drop-shaped nanostructures, conversely nanostructures derived from solid state dewetting are multifaceted. X-ray photoelectron spectroscopy (XPS) characterization revealed that the surface of nanostructures is formed by a copper(II) species CuO and Cu(OH)2. Shape of anodic branch of the cyclic voltammograms of glucose in alkali solution evidenced a convergent diffusion mechanism. Analytical performances in amperometric mode are as good as or better than other sensors based on copper oxide. Amperometric detection of glucose was done at potential as low as 0.4 V versus saturated calomel electrode by both types of electrodes. Linear range from 50μM to 10 mM, sensitivity ranging from 7 to 43μA cm-2mM-1and detection limit of 7μM was obtained. Good analytical performances were obtained by laser dewetted electrodes with a low copper content up to 1.2 by atoms percentage of the surface. Analytical performance of the proposed electrodes is compliant for the determination of glucose both in blood serum, saliva or tear.
Collapse
Affiliation(s)
- Antonino Scandurra
- Department of Physics and Astronomy Ettore Majorana of University of Catania, via Santa Sofia 64, 95123 Catania, Italy
- Institute for Microelectronics and Microsystems of National Research Council of Italy (CNR-IMM), via Santa Sofia 64, 95123 Catania, Italy
| | - Maria Censabella
- Department of Physics and Astronomy Ettore Majorana of University of Catania, via Santa Sofia 64, 95123 Catania, Italy
- Institute for Microelectronics and Microsystems of National Research Council of Italy (CNR-IMM), via Santa Sofia 64, 95123 Catania, Italy
| | - Stefano Boscarino
- Department of Physics and Astronomy Ettore Majorana of University of Catania, via Santa Sofia 64, 95123 Catania, Italy
- Institute for Microelectronics and Microsystems of National Research Council of Italy (CNR-IMM), via Santa Sofia 64, 95123 Catania, Italy
| | | | - Maria Grazia Grimaldi
- Department of Physics and Astronomy Ettore Majorana of University of Catania, via Santa Sofia 64, 95123 Catania, Italy
- Institute for Microelectronics and Microsystems of National Research Council of Italy (CNR-IMM), via Santa Sofia 64, 95123 Catania, Italy
| | - Francesco Ruffino
- Department of Physics and Astronomy Ettore Majorana of University of Catania, via Santa Sofia 64, 95123 Catania, Italy
- Institute for Microelectronics and Microsystems of National Research Council of Italy (CNR-IMM), via Santa Sofia 64, 95123 Catania, Italy
| |
Collapse
|
16
|
Tang J, Wei L, He S, Li J, Nan D, Ma L, Shen W, Kang F, Lv R, Huang Z. A Highly Sensitive Electrochemical Glucose Sensor Based on Room Temperature Exfoliated Graphite-Derived Film Decorated with Dendritic Copper. MATERIALS 2021; 14:ma14175067. [PMID: 34501157 PMCID: PMC8433722 DOI: 10.3390/ma14175067] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 08/29/2021] [Accepted: 09/02/2021] [Indexed: 12/03/2022]
Abstract
An ultrasensitive enzyme-free glucose sensor was facilely prepared by electrodepositing three-dimensional dendritic Cu on a room temperature exfoliated graphite-derived film (RTEG-F). An excellent electrocatalytic performance was demonstrated for glucose by using Cu/RTEG-F as an electrode. In terms of the high conductivity of RTEG-F and the good catalytic activity of the dendritic Cu structures, the sensor demonstrates high sensitivities of 23.237 mA/mM/cm2, R2 = 0.990, and 10.098 mA/mM/cm2, R2 = 0.999, corresponding to the concentration of glucose ranging from 0.025 mM to 1.0 mM and 1.0 mM to 2.7 mM, respectively, and the detection limit is 0.68 μM. In addition, the Cu/RTEG-F electrode demonstrates excellent anti-interference to interfering species and a high stability. Our work provides a new idea for the preparation of high-performance electrochemical enzyme-free glucose sensor.
Collapse
Affiliation(s)
- Jiaxin Tang
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China; (J.T.); (L.W.); (S.H.); (W.S.); (F.K.); (R.L.)
- School of Chemical & Environmental Engineering, China University of Mining & Technology (Beijing), Beijing 100083, China;
| | - Luo Wei
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China; (J.T.); (L.W.); (S.H.); (W.S.); (F.K.); (R.L.)
- School of Chemical & Environmental Engineering, China University of Mining & Technology (Beijing), Beijing 100083, China;
| | - Shuaijie He
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China; (J.T.); (L.W.); (S.H.); (W.S.); (F.K.); (R.L.)
| | - Jihui Li
- School of Chemical & Environmental Engineering, China University of Mining & Technology (Beijing), Beijing 100083, China;
- Correspondence: (J.L.); (Z.H.)
| | - Ding Nan
- College of Chemistry and Chemical Engineering, Inner Mongolia University, West University Street 235, Hohhot 010021, China;
- Inner Mongolia Key Laboratory of Graphite and Graphene for Energy Storage and Coating, Aimin Street 49, Hohhot 010051, China
| | - Liqiang Ma
- School of Chemical & Environmental Engineering, China University of Mining & Technology (Beijing), Beijing 100083, China;
| | - Wanci Shen
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China; (J.T.); (L.W.); (S.H.); (W.S.); (F.K.); (R.L.)
| | - Feiyu Kang
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China; (J.T.); (L.W.); (S.H.); (W.S.); (F.K.); (R.L.)
| | - Ruitao Lv
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China; (J.T.); (L.W.); (S.H.); (W.S.); (F.K.); (R.L.)
- Key Laboratory of Advanced Materials (MOE), School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China
| | - Zhenghong Huang
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China; (J.T.); (L.W.); (S.H.); (W.S.); (F.K.); (R.L.)
- Key Laboratory of Advanced Materials (MOE), School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China
- Correspondence: (J.L.); (Z.H.)
| |
Collapse
|
17
|
Aun TT, Salleh NM, Ali UFM, Manan NSA. Non-Enzymatic Glucose Sensors Involving Copper: An Electrochemical Perspective. Crit Rev Anal Chem 2021; 53:537-593. [PMID: 34477020 DOI: 10.1080/10408347.2021.1967720] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Non-enzymatic glucose sensors based on the use of copper and its oxides have emerged as promising candidates to replace enzymatic glucose sensors owing to their stability, ease of fabrication, and superior sensitivity. This review explains the theories of the mechanism of glucose oxidation on copper transition metal electrodes. It also presents an overview on the development of among the best non-enzymatic copper-based glucose sensors in the past 10 years. A brief description of methods, interesting findings, and important performance parameters are provided to inspire the reader and researcher to create new improvements in sensor design. Finally, several important considerations that pertain to the nano-structuring of the electrode surface is provided.
Collapse
Affiliation(s)
- Tan Tiek Aun
- Faculty of Science, Department of Chemistry, Universiti Malaya, Kuala Lumpur, Malaysia.,University Malaya Centre for Ionic Liquids (UMCiL), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Noordini Mohamad Salleh
- Faculty of Science, Department of Chemistry, Universiti Malaya, Kuala Lumpur, Malaysia.,Faculty of Science, Department of Chemistry, Centre for Fundamental and Frontier Sciences in Nanostructure Self-Assembly, Universiti Malaya, Kuala Lumpur, Malaysia
| | - Umi Fazara Md Ali
- Chemical Engineering Programme, Faculty of Chemical Engineering & Technology, Universiti Malaysia Perlis, Arau, Malaysia.,Centre of Excellence for Biomass Utilization (COEBU), Universiti Malaysia Perlis, Arau, Malaysia
| | - Ninie Suhana Abdul Manan
- Faculty of Science, Department of Chemistry, Universiti Malaya, Kuala Lumpur, Malaysia.,University Malaya Centre for Ionic Liquids (UMCiL), Universiti Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
18
|
Xue Q, Kan X, Pan Z, Li Z, Pan W, Zhou F, Duan X. An intelligent face mask integrated with high density conductive nanowire array for directly exhaled coronavirus aerosols screening. Biosens Bioelectron 2021; 186:113286. [PMID: 33990035 PMCID: PMC8091738 DOI: 10.1016/j.bios.2021.113286] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 04/19/2021] [Accepted: 04/23/2021] [Indexed: 01/10/2023]
Abstract
The current ongoing outbreak of Coronavirus Disease 2019 (COVID-19) has globally affected the lives of more than one hundred million people. RT-PCR based molecular test is recommended as the gold standard method for diagnosing current infections. However, transportation and processing of the clinical sample for detecting virus require an expert operator and long processing time. Testing device enables on-site virus detection could reduce the sample-to-answer time, which plays a central role in containing the pandemic. In this work, we proposed an intelligent face mask, where a flexible immunosensor based on high density conductive nanowire array, a miniaturized impedance circuit, and wireless communication units were embedded. The sub-100 nm size and the gap between the neighbored nanowires facilitate the locking of nanoscale virus particles by the nanowire arrays and greatly improve the detection efficiency. Such a point-of-care (POC) system was demonstrated for coronavirus 'spike' protein and whole virus aerosol detection in simulated human breath. Detection of viral concentration as low as 7 pfu/mL from the atomized sample of coronavirus aerosol mimic was achieved in only 5 min. The POC systems can be readily applied for preliminary screening of coronavirus infections on-site and may help to understand the COVID-19 progression while a patient is under prescribed therapy.
Collapse
Affiliation(s)
- Qiannan Xue
- State Key Laboratory of Precision Measuring Technology & Instruments, School of Precision Instruments and Optoelec-tronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Xinyuan Kan
- State Key Laboratory of Precision Measuring Technology & Instruments, School of Precision Instruments and Optoelec-tronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Zhihao Pan
- State Key Laboratory of Precision Measuring Technology & Instruments, School of Precision Instruments and Optoelec-tronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Zheyu Li
- State Key Laboratory of Precision Measuring Technology & Instruments, School of Precision Instruments and Optoelec-tronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Wenwei Pan
- State Key Laboratory of Precision Measuring Technology & Instruments, School of Precision Instruments and Optoelec-tronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Feng Zhou
- State Key Laboratory of Precision Measuring Technology & Instruments, School of Precision Instruments and Optoelec-tronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Xuexin Duan
- State Key Laboratory of Precision Measuring Technology & Instruments, School of Precision Instruments and Optoelec-tronics Engineering, Tianjin University, Tianjin, 300072, China.
| |
Collapse
|
19
|
Hassan MH, Vyas C, Grieve B, Bartolo P. Recent Advances in Enzymatic and Non-Enzymatic Electrochemical Glucose Sensing. SENSORS (BASEL, SWITZERLAND) 2021; 21:4672. [PMID: 34300412 PMCID: PMC8309655 DOI: 10.3390/s21144672] [Citation(s) in RCA: 93] [Impact Index Per Article: 31.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 06/28/2021] [Accepted: 07/06/2021] [Indexed: 11/17/2022]
Abstract
The detection of glucose is crucial in the management of diabetes and other medical conditions but also crucial in a wide range of industries such as food and beverages. The development of glucose sensors in the past century has allowed diabetic patients to effectively manage their disease and has saved lives. First-generation glucose sensors have considerable limitations in sensitivity and selectivity which has spurred the development of more advanced approaches for both the medical and industrial sectors. The wide range of application areas has resulted in a range of materials and fabrication techniques to produce novel glucose sensors that have higher sensitivity and selectivity, lower cost, and are simpler to use. A major focus has been on the development of enzymatic electrochemical sensors, typically using glucose oxidase. However, non-enzymatic approaches using direct electrochemistry of glucose on noble metals are now a viable approach in glucose biosensor design. This review discusses the mechanisms of electrochemical glucose sensing with a focus on the different generations of enzymatic-based sensors, their recent advances, and provides an overview of the next generation of non-enzymatic sensors. Advancements in manufacturing techniques and materials are key in propelling the field of glucose sensing, however, significant limitations remain which are highlighted in this review and requires addressing to obtain a more stable, sensitive, selective, cost efficient, and real-time glucose sensor.
Collapse
Affiliation(s)
- Mohamed H. Hassan
- Department of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester M13 9PL, UK; (M.H.H.); (C.V.)
| | - Cian Vyas
- Department of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester M13 9PL, UK; (M.H.H.); (C.V.)
| | - Bruce Grieve
- Department of Electrical & Electronic Engineering, University of Manchester, Manchester M13 9PL, UK;
| | - Paulo Bartolo
- Department of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester M13 9PL, UK; (M.H.H.); (C.V.)
| |
Collapse
|
20
|
Developments of the Electroactive Materials for Non-Enzymatic Glucose Sensing and Their Mechanisms. ELECTROCHEM 2021. [DOI: 10.3390/electrochem2020025] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
A comprehensive review of the electroactive materials for non-enzymatic glucose sensing and sensing devices has been performed in this work. A general introduction for glucose sensing, a facile electrochemical technique for glucose detection, and explanations of fundamental mechanisms for the electro-oxidation of glucose via the electrochemical technique are conducted. The glucose sensing materials are classified into five major systems: (1) mono-metallic materials, (2) bi-metallic materials, (3) metallic-oxide compounds, (4) metallic-hydroxide materials, and (5) metal-metal derivatives. The performances of various systems within this decade have been compared and explained in terms of sensitivity, linear regime, the limit of detection (LOD), and detection potentials. Some promising materials and practicable methodologies for the further developments of glucose sensors have been proposed. Firstly, the atomic deposition of alloys is expected to enhance the selectivity, which is considered to be lacking in non-enzymatic glucose sensing. Secondly, by using the modification of the hydrophilicity of the metallic-oxides, a promoted current response from the electro-oxidation of glucose is expected. Lastly, by taking the advantage of the redistribution phenomenon of the oxide particles, the usage of the noble metals is foreseen to be reduced.
Collapse
|
21
|
Yuan K, Zhang Y, Huang S, Yang S, Zhao S, Liu F, Peng Q, Zhao Y, Zhang G, Fan J, Zang G. Copper Nanoflowers on Carbon Cloth as a Flexible Electrode Toward Both Enzymeless Electrocatalytic Glucose and H
2
O
2. ELECTROANAL 2021. [DOI: 10.1002/elan.202100029] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Kun Yuan
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Yuchan Zhang
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Shihao Huang
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Shengfei Yang
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Shuang Zhao
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
- Key Laboratory for Biorheological Science and Technology of Ministry of Education State and Local Joint Engineering Laboratory for Vascular Implants Bioengineering College of Chongqing University Chongqing 400030 China
| | - Fangxin Liu
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Qianyu Peng
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Yinping Zhao
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Guangyuan Zhang
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Jingchuan Fan
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Guangchao Zang
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| |
Collapse
|
22
|
Khairullina EM, Panov MS, Andriianov VS, Ratautas K, Tumkin II, Račiukaitis G. High rate fabrication of copper and copper-gold electrodes by laser-induced selective electroless plating for enzyme-free glucose sensing. RSC Adv 2021; 11:19521-19530. [PMID: 35479213 PMCID: PMC9033606 DOI: 10.1039/d1ra01565f] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Accepted: 05/23/2021] [Indexed: 12/31/2022] Open
Abstract
In the current study, the method of Selective Surface Activation Induced by Laser (SSAIL) was used for the fabrication of metallic and bimetallic structures based on copper and gold on the surface of glass and glass-ceramics. It was shown that the fabricated electrodes are suitable for non-enzymatic detection of biologically essential analytes such as glucose. The implemented approach allows performing high-rate metallization of various dielectrics. Voltammetric methods were applied to evaluate the electrocatalytic activity of the obtained structures, which were used as working electrodes. The most promising results were revealed by copper–gold electrode structures manufactured on glass-ceramics. For these structures, sensitivity towards glucose sensing was 3060 μA mM−1 cm−2. The linear range of glucose detection varied between 0.3 and 1000 μM. Besides, the manufactured electrodes exhibited high selectivity and long-term stability. In the current study, the method of Selective Surface Activation Induced by Laser (SSAIL) was used for the fabrication of metallic and bimetallic structures based on copper and gold on the surface of glass and glass-ceramics.![]()
Collapse
Affiliation(s)
- Evgeniia M Khairullina
- Saint Petersburg State University 7/9 Universitetskaya nab. St. Petersburg 199034 Russia
| | - Maxim S Panov
- Saint Petersburg State University 7/9 Universitetskaya nab. St. Petersburg 199034 Russia
| | - Vladimir S Andriianov
- Saint Petersburg State University 7/9 Universitetskaya nab. St. Petersburg 199034 Russia
| | - Karolis Ratautas
- Center for Physical Sciences and Technology 231 Savanoriu ave. Vilnius 02300 Lithuania
| | - Ilya I Tumkin
- Saint Petersburg State University 7/9 Universitetskaya nab. St. Petersburg 199034 Russia
| | - Gediminas Račiukaitis
- Center for Physical Sciences and Technology 231 Savanoriu ave. Vilnius 02300 Lithuania
| |
Collapse
|
23
|
Copper and Nickel Microsensors Produced by Selective Laser Reductive Sintering for Non-Enzymatic Glucose Detection. MATERIALS 2021; 14:ma14102493. [PMID: 34065930 PMCID: PMC8151703 DOI: 10.3390/ma14102493] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 05/04/2021] [Accepted: 05/07/2021] [Indexed: 11/30/2022]
Abstract
In this work, the method of selective laser reductive sintering was used to fabricate the sensor-active copper and nickel microstructures on the surface of glass-ceramics suitable for non-enzymatic detection of glucose. The calculated sensitivities for these microsensors are 1110 and 2080 μA mM−1·cm−2 for copper and nickel, respectively. Linear regime of enzymeless glucose sensing is provided between 0.003 and 3 mM for copper and between 0.01 and 3 mM for nickel. Limits of glucose detection for these manufactured micropatterns are equal to 0.91 and 2.1 µM for copper and nickel, respectively. In addition, the fabricated materials demonstrate rather good selectivity, long-term stability and reproducibility.
Collapse
|
24
|
Khand AA, Lakho SA, Tahira A, Ubaidullah M, Alothman AA, Aljadoa K, Nafady A, Ibupoto ZH. Facile Electrochemical Determination of Methotrexate (MTX) Using Glassy Carbon Electrode-Modified with Electronically Disordered NiO Nanostructures. NANOMATERIALS 2021; 11:nano11051266. [PMID: 34065856 PMCID: PMC8150394 DOI: 10.3390/nano11051266] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 04/25/2021] [Accepted: 04/27/2021] [Indexed: 02/01/2023]
Abstract
Recently, the oxidative behavior of methotrexate (MTX) anticancer drug is highly demanded, due to its side effects on healthy cells, despite being a very challenging task. In this study, we have prepared porous NiO material using sodium sulfate as an electronic disorder reagent by hydrothermal method and found it highly sensitive and selective for the oxidation of MTX. The synthesized NiO nanostructures were characterized by scanning electron microscope (SEM) and X-ray diffraction (XRD) techniques. These physical characterizations delineated the porous morphology and cubic crystalline phase of NiO. Different electrochemical approaches have been utilized to determine the MTX concentrations in 0.04 M Britton-Robinson buffer (BRB) at pH 2 using glassy carbon electrode (GCE)-modified with electronically disordered NiO nanostructures. The linear range for MTX using cyclic voltammetry (CV) was found to be from 5 to 30 nM, and the limit of detection (LOD) and limit of quantification (LOQ) were 1.46 nM and 4.86 nM, respectively, whereas the linear range obtained via linear sweep voltammetry (LSV) was estimated as 15-90 nM with LOD and LOQ of 0.819 nM and 2.713 nM, respectively. Additionally, amperometric studies revealed a linear range from 10 to70 nM with LOD and LOQ of 0.1 nM and 1.3 nM, respectively. Importantly, MTX was successfully monitored in pharmaceutical products using the standard recovery method. Thus, the proposed approach for the synthesis of active metal oxide materials could be sued for the determination of other anticancer drugs in real samples and other biomedical applications.
Collapse
Affiliation(s)
- Aftab A. Khand
- School of Life Sciences, Tsinghua University, Beijing 100084, China
- Department of Physiology, University of Sindh, Jamshoro 76080, Sindh, Pakistan
- Correspondence: (A.A.K.); (S.A.L.); (Z.H.I.)
| | - Saeed A. Lakho
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy and Pharmaceutical Sciences, University of Karachi, Karachi 75270, Sindh, Pakistan
- Correspondence: (A.A.K.); (S.A.L.); (Z.H.I.)
| | - Aneela Tahira
- Dr. M.A Kazi Institute of Chemistry, University of Sindh, Jamshoro 76080, Sindh, Pakistan;
| | - Mohd Ubaidullah
- Department of Chemistry, College of Science, King Saud University, Riyadh 11451, Saudi Arabia; (M.U.); (A.A.A.); (K.A.); (A.N.)
| | - Asma A. Alothman
- Department of Chemistry, College of Science, King Saud University, Riyadh 11451, Saudi Arabia; (M.U.); (A.A.A.); (K.A.); (A.N.)
| | - Khoulwod Aljadoa
- Department of Chemistry, College of Science, King Saud University, Riyadh 11451, Saudi Arabia; (M.U.); (A.A.A.); (K.A.); (A.N.)
| | - Ayman Nafady
- Department of Chemistry, College of Science, King Saud University, Riyadh 11451, Saudi Arabia; (M.U.); (A.A.A.); (K.A.); (A.N.)
| | - Zafar H. Ibupoto
- Dr. M.A Kazi Institute of Chemistry, University of Sindh, Jamshoro 76080, Sindh, Pakistan;
- Correspondence: (A.A.K.); (S.A.L.); (Z.H.I.)
| |
Collapse
|
25
|
Dong Q, Ryu H, Lei Y. Metal oxide based non-enzymatic electrochemical sensors for glucose detection. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.137744] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
26
|
Taji Z, Ensafi AA, Heydari‐Soureshjani E, Rezaei B. A Novel Non‐enzymatic Selective and Sensitive Glucose Sensor Based on Nickel‐Copper Oxide@3D‐rGO/MWCNTs. ELECTROANAL 2021. [DOI: 10.1002/elan.202060151] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Zahra Taji
- Department of Chemistry Isfahan University of Technology Isfahan 84156-83111 Iran
| | - Ali A. Ensafi
- Department of Chemistry Isfahan University of Technology Isfahan 84156-83111 Iran
| | | | - Behzad Rezaei
- Department of Chemistry Isfahan University of Technology Isfahan 84156-83111 Iran
| |
Collapse
|
27
|
Fatema KN, Oh WC. A comparative electrochemical study of non-enzymatic glucose, ascorbic acid, and albumin detection by using a ternary mesoporous metal oxide (ZrO 2, SiO 2 and In 2O 3) modified graphene composite based biosensor. RSC Adv 2021; 11:4256-4269. [PMID: 35424336 PMCID: PMC8694395 DOI: 10.1039/d0ra09886h] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2020] [Accepted: 12/15/2020] [Indexed: 11/21/2022] Open
Abstract
In this study, we present an electrochemical investigation of a ternary mesoporous metal oxide (ZrO2, SiO2 and In2O3) modified graphene composite for non-enzymatic glucose, ascorbic acid, and albumin detection in urine at physiological pH. Synergetic property of ZrO2-Ag-G-SiO2 and In2O3-G-SiO2 were investigated via cyclic voltammetry (CV) using FTO glass and copper-foil electrodes with no prerequisite of solid antacid expansion. The mesoporous ZrO2-Ag-G-SiO2 and In2O3-G-SiO2 composites were synthesized and characterized using XRD, SEM, TEM, Raman spectroscopy, XPS, DRS, BET, and photocurrent measurements. Upon increasing the glucose concentration from 0 to 3 mM, CV results indicated two anodic peaks at +0.18 V and +0.42 V versus Ag/AgCl, corresponding to Zr3+ and Zr4+, respectively, considering the presence of glucose in urine. Moreover, the effects of high surface area In2O3-G-SiO2 were observed upon the examination of ZrO2-Ag-G-SiO2. In2O3-G-SiO2 demonstrated a decent electrochemical pattern in glucose, ascorbic acid, and albumin sensing. Nevertheless, insignificant synergistic effects were observed in In2O3-G, ZrO2-G, and ZrO2-G-SiO2. In2O3-G-SiO2 performed well under a wide range of electrolytes and urine, and showed no activity toward uric acid, suggesting potential for biodetection in urine.
Collapse
Affiliation(s)
- Kamrun Nahar Fatema
- Department of Advanced Materials Science & Engineering, Hanseo University Seosan-si Chungnam Korea 356-706 +82-41-688-3352 +82-41-660-1337
| | - Won-Chun Oh
- Department of Advanced Materials Science & Engineering, Hanseo University Seosan-si Chungnam Korea 356-706 +82-41-688-3352 +82-41-660-1337
- College of Materials Science and Engineering, Anhui University of Science & Technology Huainan 232001 PR China
| |
Collapse
|
28
|
Fang L, Cai Y, Huang B, Cao Q, Zhu Q, Tu T, Ye X, Liang B. A highly sensitive nonenzymatic glucose sensor based on Cu/Cu2O composite nanoparticles decorated single carbon fiber. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2020.114888] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
29
|
Nanostructured Anodic Copper Oxides as Catalysts in Electrochemical and Photoelectrochemical Reactions. Catalysts 2020. [DOI: 10.3390/catal10111338] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
Recently, nanostructured copper oxides formed via anodizing have been intensively researched due to their potential catalytic applications in emerging issues. The anodic Cu2O and CuO nanowires or nanoneedles are attractive photo- and electrocatalysts since they show wide array of desired electronic and morphological features, such as highly-developed surface area. In CO2 electrochemical reduction reaction (CO2RR) copper and copper-based nanostructures indicate unique adsorption properties to crucial reaction intermediates. Furthermore, anodized copper-based materials enable formation of C2+ hydrocarbons and alcohols with enhanced selectivity. Moreover, anodic copper oxides provide outstanding turnover frequencies in electrochemical methanol oxidation at lowered overpotentials. Therefore, they can be considered as precious metals electrodes substituents in direct methanol fuel cells. Additionally, due to the presence of Cu(III)/Cu(II) redox couple, these materials find application as electrodes for non-enzymatic glucose sensors. In photoelectrochemistry, Cu2O-CuO heterostructures of anodic copper oxides with highly-developed surface area are attractive for water splitting. All the above-mentioned aspects of anodic copper oxides derived catalysts with state-of-the-art background have been reviewed within this paper.
Collapse
|
30
|
Significance of nanomaterials in electrochemical glucose sensors: An updated review (2016-2020). Biosens Bioelectron 2020; 159:112165. [DOI: 10.1016/j.bios.2020.112165] [Citation(s) in RCA: 156] [Impact Index Per Article: 39.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 03/05/2020] [Accepted: 03/20/2020] [Indexed: 02/02/2023]
|
31
|
Belgherbi O, Chouder D, Lakhdari D, Dehchar C, Laidoudi S, Lamiri L, Hamam A, Seid L. Enzyme-Free Glucose Sensor Based on Star-Like Copper Particles-Polyaniline Composite Film. J Inorg Organomet Polym Mater 2020. [DOI: 10.1007/s10904-020-01554-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
32
|
Wei C, Kang C, Liu Q. Ag nanosheets grown on Cu nanowire-based flexible films for sensitive non-enzymatic glucose sensors. NANOTECHNOLOGY 2020; 31:115501. [PMID: 31751969 DOI: 10.1088/1361-6528/ab59ea] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Cu nanowire (Cu NW) and Ag nanosheet (Ag NS) bimetallic nanocomposites were fabricated on a flexible polyethylene terephthalate (PET) slice for non-enzymatic glucose sensing via a facile two-step approach, vacuum filtration, and galvanic displacement. Low-cost Cu NW-based conductive films were employed as the conductive substrates to substitute the traditional glassy carbon electrodes or indium tin oxide electrodes. The highly stable Ag NSs grow directly on the surface of Cu NWs without additional binders. The AgNO3 concentration and displacement time were adjusted to control the consumption of Cu NWs and the growth of Ag nanostructures. With the large load of Ag and the great connection of Cu NWs, a high sensitivity of 2033 μA mM-1cm-2, a fast amperometric response of 2 s, a wide linear range of 0.0015-4.02 mM, and a satisfactory result in human serum analysis were obtained by this novel Ag NS/Cu NW/PET sensor. Especially the sensitivity of the sensor was over four-fold higher than that of pure Cu NWs/PET, benefiting from the synergistic effect of bimetals. Furthermore, the Ag NS/Cu NW/PET sensor demonstrated a stable amperometric signal against mechanical bending. The material holds promise to use to fabricate flexible electrochemical devices.
Collapse
Affiliation(s)
- Chenhuinan Wei
- School of Physics and Technology, Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education, Wuhan University, Wuhan 430072, People's Republic of China
| | | | | |
Collapse
|
33
|
Sridara T, Upan J, Saianand G, Tuantranont A, Karuwan C, Jakmunee J. Non-Enzymatic Amperometric Glucose Sensor Based on Carbon Nanodots and Copper Oxide Nanocomposites Electrode. SENSORS (BASEL, SWITZERLAND) 2020; 20:E808. [PMID: 32024275 PMCID: PMC7038693 DOI: 10.3390/s20030808] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Revised: 01/25/2020] [Accepted: 01/31/2020] [Indexed: 01/01/2023]
Abstract
In this research work, a non-enzymatic amperometric sensor for the determination of glucose was designed based on carbon nanodots (C-dots) and copper oxide (CuO) nanocomposites (CuO-C-dots). The CuO-C-dots nanocomposites were modified on the surface of a screen-printed carbon electrode (SPCE) to increase the sensitivity and selectivity of the glucose sensor. The as-synthesized materials were further analyzed for physico-chemical properties through characterization tools such as transmission electron microscopy (TEM) and Fourier-transform infrared spectroscopy (FTIR); and their electrochemical performance was also studied. The SPCE modified with CuO-C-dots possess desirable electrocatalytic properties for glucose oxidation in alkaline solutions. Moreover, the proposed sensing platform exhibited a linear range of 0.5 to 2 and 2 to 5 mM for glucose detection with high sensitivity (110 and 63.3 µA mM-1cm-2), and good selectivity and stability; and could potentially serve as an effective alternative method of glucose detection.
Collapse
Affiliation(s)
- Tharinee Sridara
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; (T.S.); (J.U.)
- The Graduate School, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Jantima Upan
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; (T.S.); (J.U.)
- The Graduate School, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Gopalan Saianand
- Faculty of Science, The University of Newcastle, Callaghan, NSW 2308, Australia;
| | - Adisorn Tuantranont
- National Security and Dual-Use Technology Center, National Science and Technology Development Agency, Pathumthani 12120, Thailand;
- Center of Advanced Materials of Printed Electronics and Sensors, Materials Science Research Center, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand;
| | - Chanpen Karuwan
- Center of Advanced Materials of Printed Electronics and Sensors, Materials Science Research Center, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand;
| | - Jaroon Jakmunee
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; (T.S.); (J.U.)
- Center of Advanced Materials of Printed Electronics and Sensors, Materials Science Research Center, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand;
- Center of Excellence for Innovation in Chemistry and Research Center on Chemistry for Development of Health Promoting Products from Northern Resources, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand
| |
Collapse
|
34
|
A highly sensitive non-enzymatic glucose sensor based on CuS nanosheets modified Cu2O/CuO nanowire arrays. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.135630] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
35
|
Xu H, Han F, Xia C, Wang S, Zhuiykov S, Zheng G. Spinel sub-stoichiometric CuxCoyO4 nano-wire framework thin-film electrode for enhanced electrochemical non-enzymatic sensing of glucose. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2019.135295] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
36
|
Dewetted Gold Nanostructures onto Exfoliated Graphene Paper as High Efficient Glucose Sensor. NANOMATERIALS 2019; 9:nano9121794. [PMID: 31888252 PMCID: PMC6955950 DOI: 10.3390/nano9121794] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Revised: 12/09/2019] [Accepted: 12/13/2019] [Indexed: 11/17/2022]
Abstract
Non-enzymatic electrochemical glucose sensing was obtained by gold nanostructures on graphene paper, produced by laser or thermal dewetting of 1.6 and 8 nm-thick Au layers, respectively. Nanosecond laser annealing produces spherical nanoparticles (AuNPs) through the molten-phase dewetting of the gold layer and simultaneous exfoliation of the graphene paper. The resulting composite electrodes were characterized by X-ray photoelectron spectroscopy, cyclic voltammetry, scanning electron microscopy, micro Raman spectroscopy and Rutherford back-scattering spectrometry. Laser dewetted electrode presents graphene nanoplatelets covered by spherical AuNPs. The sizes of AuNPs are in the range of 10-150 nm. A chemical shift in the XPS Au4f core-level of 0.25-0.3 eV suggests the occurrence of AuNPs oxidation, which are characterized by high stability under the electrochemical test. Thermal dewetting leads to electrodes characterized by faceted not oxidized gold structures. Glucose was detected in alkali media at potential of 0.15-0.17 V vs. saturated calomel electrode (SCE), in the concentration range of 2.5μM-30 mM, exploiting the peak corresponding to the oxidation of two electrons. Sensitivity of 1240 µA mM-1 cm-2, detection limit of 2.5 μM and quantifications limit of 20 μM were obtained with 8 nm gold equivalent thickness. The analytical performances are very promising and comparable to the actual state of art concerning gold based electrodes.
Collapse
|
37
|
Zhai Z, Leng B, Yang N, Yang B, Liu L, Huang N, Jiang X. Rational Construction of 3D-Networked Carbon Nanowalls/Diamond Supporting CuO Architecture for High-Performance Electrochemical Biosensors. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1901527. [PMID: 31074930 DOI: 10.1002/smll.201901527] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2019] [Revised: 04/24/2019] [Indexed: 05/27/2023]
Abstract
Tremendous demands for highly sensitive and selective nonenzymatic electrochemical biosensors have motivated intensive research on advanced electrode materials with high electrocatalytic activity. Herein, the 3D-networked CuO@carbon nanowalls/diamond (C/D) architecture is rationally designed, and it demonstrates wide linear range (0.5 × 10-6 -4 × 10-3 m), high sensitivity (1650 µA cm-2 mm-1 ), and low detection limit (0.5 × 10-6 m), together with high selectivity, great long-term stability, and good reproducibility in glucose determination. The outstanding performance of the CuO@C/D electrode can be ascribed to the synergistic effect coming from high-electrocatalytic-activity CuO nanoparticles and 3D-networked conductive C/D film. The C/D film is composed of carbon nanowalls and diamond nanoplatelets; and owing to the large surface area, accessible open surfaces, and high electrical conduction, it works as an excellent transducer, greatly accelerating the mass- and charge-transport kinetics of electrocatalytic reaction on the CuO biorecognition element. Besides, the vertical aligned diamond nanoplatelet scaffolds could improve structural and mechanical stability of the designed electrode in long-term performance. The excellent CuO@C/D electrode promises potential application in practical glucose detection, and the strategy proposed here can also be extended to construct other biorecognition elements on the 3D-networked conductive C/D transducer for various high-performance nonenzymatic electrochemical biosensors.
Collapse
Affiliation(s)
- Zhaofeng Zhai
- Shenyang National Laboratory for Materials Science (SYNL), Institute of Metal Research (IMR), Chinese Academy of Sciences (CAS), No.72 Wenhua Road, Shenyang, 110016, China
- School of Materials Science and Engineering, University of Science and Technology of China, No.72 Wenhua Road, Shenyang, 110016, China
| | - Bing Leng
- Department of Plastic Surgery, The First Affiliated Hospital of China Medical University, No.155 North Nanjing Street, Shenyang, 110001, China
| | - Nianjun Yang
- Institute of Materials Engineering, University of Siegen, No.9-11 Paul-Bonatz-Str., Siegen, 57076, Germany
| | - Bing Yang
- Shenyang National Laboratory for Materials Science (SYNL), Institute of Metal Research (IMR), Chinese Academy of Sciences (CAS), No.72 Wenhua Road, Shenyang, 110016, China
| | - Lusheng Liu
- Shenyang National Laboratory for Materials Science (SYNL), Institute of Metal Research (IMR), Chinese Academy of Sciences (CAS), No.72 Wenhua Road, Shenyang, 110016, China
| | - Nan Huang
- Shenyang National Laboratory for Materials Science (SYNL), Institute of Metal Research (IMR), Chinese Academy of Sciences (CAS), No.72 Wenhua Road, Shenyang, 110016, China
| | - Xin Jiang
- Shenyang National Laboratory for Materials Science (SYNL), Institute of Metal Research (IMR), Chinese Academy of Sciences (CAS), No.72 Wenhua Road, Shenyang, 110016, China
- Institute of Materials Engineering, University of Siegen, No.9-11 Paul-Bonatz-Str., Siegen, 57076, Germany
| |
Collapse
|
38
|
Viswanathan P, Park J, Kang DK, Hong JD. Polydopamine-wrapped Cu/Cu(II) nano-heterostructures: An efficient electrocatalyst for non-enzymatic glucose detection. Colloids Surf A Physicochem Eng Asp 2019. [DOI: 10.1016/j.colsurfa.2019.123689] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
39
|
Wang T, Li L, Tian X, Jin H, Tang K, Hou S, Zhou H, Yu X. 3D-printed interdigitated graphene framework as superior support of metal oxide nanostructures for remarkable micro-pseudocapacitors. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2019.06.163] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
40
|
Dat PV, Viet NX. Facile synthesis of novel areca flower like Cu2O nanowire on copper foil for a highly sensitive enzyme-free glucose sensor. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 103:109758. [DOI: 10.1016/j.msec.2019.109758] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2019] [Revised: 05/10/2019] [Accepted: 05/14/2019] [Indexed: 01/01/2023]
|
41
|
Cheng S, Gao X, DelaCruz S, Chen C, Tang Z, Shi T, Carraro C, Maboudian R. In situ formation of metal-organic framework derived CuO polyhedrons on carbon cloth for highly sensitive non-enzymatic glucose sensing. J Mater Chem B 2019; 7:4990-4996. [PMID: 31411623 DOI: 10.1016/j.snb.2019.126860] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Metal-organic frameworks (MOFs) are considered promising templates for the fabrication of nanostructured materials with high porosities and high surface areas, which are important parameters for enhanced performance in sensing applications. Here, a facile in situ synthetic strategy to construct MOF-derived porous CuO polyhedrons on carbon cloth (CC) is reported. Uniform Cu(OH)2 nanorods are first synthesized on carbon cloth, followed by the conversion of Cu(OH)2 nanorods into porous CuO polyhedrons via a copper-based MOF, Cu-BTC, as the intermediate species. When evaluated as a glucose sensing electrode, the as-fabricated CuO polyhedrons/CC composite exhibits a high sensitivity of 13 575 μA mM-1 cm-2 with a fast response time (t90) of 2.3 s and a low detection limit of 0.46 μM. This work exemplifies the rational fabrication of porous nanostructures on conductive substrates for enhanced performance in glucose detection.
Collapse
Affiliation(s)
- Siyi Cheng
- Berkeley Sensor & Actuator Center, University of California, Berkeley, California 94720, USA. and Department of Chemical and Biomolecular Engineering, University of California, Berkeley, California 94720, USA and State Key Laboratory of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Xiang Gao
- Berkeley Sensor & Actuator Center, University of California, Berkeley, California 94720, USA. and Department of Chemical and Biomolecular Engineering, University of California, Berkeley, California 94720, USA
| | - Steven DelaCruz
- Berkeley Sensor & Actuator Center, University of California, Berkeley, California 94720, USA. and Department of Chemical and Biomolecular Engineering, University of California, Berkeley, California 94720, USA
| | - Chen Chen
- State Key Laboratory of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Zirong Tang
- State Key Laboratory of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Tielin Shi
- State Key Laboratory of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Carlo Carraro
- Berkeley Sensor & Actuator Center, University of California, Berkeley, California 94720, USA. and Department of Chemical and Biomolecular Engineering, University of California, Berkeley, California 94720, USA
| | - Roya Maboudian
- Berkeley Sensor & Actuator Center, University of California, Berkeley, California 94720, USA. and Department of Chemical and Biomolecular Engineering, University of California, Berkeley, California 94720, USA
| |
Collapse
|
42
|
Le HT, Tran DT, Luyen Doan TL, Kim NH, Lee JH. Hierarchical Cu@CuxO nanowires arrays-coated gold nanodots as a highly sensitive self-supported electrocatalyst for L-cysteine oxidation. Biosens Bioelectron 2019; 139:111327. [DOI: 10.1016/j.bios.2019.111327] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Revised: 04/29/2019] [Accepted: 05/14/2019] [Indexed: 10/26/2022]
|
43
|
Sandwich nanoporous framework decorated with vertical CuO nanowire arrays for electrochemical glucose sensing. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2019.01.033] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
44
|
Zhang SY, Zhu HL, Zheng YQ. Surface modification of CuO nanoflake with Co3O4 nanowire for oxygen evolution reaction and electrocatalytic reduction of CO2 in water to syngas. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2018.12.183] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
45
|
Muthurasu A, Kim HY. Fabrication of Hierarchically Structured MOF‐Co
3
O
4
on Well‐aligned CuO Nanowire with an Enhanced Electrocatalytic Property. ELECTROANAL 2019. [DOI: 10.1002/elan.201800823] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Alagan Muthurasu
- Department of BIN Convergence TechnologyChonbuk National University Republic Korea
| | - Hak Yong Kim
- Department of BIN Convergence TechnologyChonbuk National University Republic Korea
- Department of Organic Materials and Fiber EngineeringChonbuk National University Jeonju 561-756 Republic of Korea
| |
Collapse
|
46
|
Long L, Liu X, Chen L, Li D, Jia J. A hollow CuOx/NiOy nanocomposite for amperometric and non-enzymatic sensing of glucose and hydrogen peroxide. Mikrochim Acta 2019; 186:74. [DOI: 10.1007/s00604-018-3183-x] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Accepted: 12/14/2018] [Indexed: 01/06/2023]
|
47
|
Amin BG, Masud J, Nath M. A non-enzymatic glucose sensor based on a CoNi2Se4/rGO nanocomposite with ultrahigh sensitivity at low working potential. J Mater Chem B 2019; 7:2338-2348. [DOI: 10.1039/c9tb00104b] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
A CoNi2Se4–rGO nanocomposite fabricated on Ni foam shows excellent efficiency for non-enzymatic glucose sensing at low applied potential.
Collapse
Affiliation(s)
| | - Jahangir Masud
- Department of Chemistry
- Missouri University of Science & Technology
- Rolla
- USA
| | - Manashi Nath
- Department of Chemistry
- Missouri University of Science & Technology
- Rolla
- USA
| |
Collapse
|
48
|
Wang F, Niu X, Wang W, Jing W, Huang Y, Zhang J. Green synthesis of Pd nanoparticles via extracted polysaccharide applied to glucose detection. J Taiwan Inst Chem Eng 2018. [DOI: 10.1016/j.jtice.2018.08.022] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
49
|
Huang M, He D, Wang M, Jiang P. NiMoO4 nanosheet arrays anchored on carbon cloth as 3D open electrode for enzyme-free glucose sensing with improved electrocatalytic activity. Anal Bioanal Chem 2018; 410:7921-7929. [DOI: 10.1007/s00216-018-1413-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Revised: 08/25/2018] [Accepted: 10/01/2018] [Indexed: 02/07/2023]
|
50
|
Guo T, Gao J, Qin X, Zhang X, Xue H. A Novel Glucose Biosensor Based on Hierarchically Porous Block Copolymer Film. Polymers (Basel) 2018; 10:E723. [PMID: 30960648 PMCID: PMC6403682 DOI: 10.3390/polym10070723] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2018] [Revised: 06/27/2018] [Accepted: 06/28/2018] [Indexed: 11/16/2022] Open
Abstract
Enzymatic biosensors are widely used in clinical diagnostics, and electrode materials are essential for both the efficient immobilization of enzyme and the fast electron transfer between the active sites of enzyme and electrode surface. Electrode materials with a hierarchically porous structure can not only increase the specific surface area but also promote the electron transfer, facilitating the catalysis reaction. Block copolymer is a good candidate for preparation of film with a hierarchically porous structure due to its unique characteristics of self-assembly and phase separation. In the current work, hierarchically porous block copolymer film containing both micropores and nanopores was prepared by spinodal decomposition induced phase separation. The resultant copolymer film was adopted as the electrode material to immobilize glucose oxidase (GOx) for construction of an enzyme biosensor. Scanning electron microscopy (SEM), contact angle (CA) measurements, and Fourier-transform infrared (FTIR) and electrochemical impendence spectroscopy (EIS) were adopted to investigate the microstructure of the as-developed biosensor. Results demonstrated that the hierarchically porous block copolymer film offered a favorable and biocompatible microenvironment for proteins. These as-prepared glucose biosensors possessed a wide linear range (10⁻4500 μM), a low detection limit (0.05 μM), quick response (2 s), excellent stability, and selectivity. This work demonstrates that hierarchically porous block copolymer film is a good matrix candidate for the immobilization of the enzyme and provides a potential electrode material to construct novel biosensors with excellent performance.
Collapse
Affiliation(s)
- Teng Guo
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, China.
| | - Jiefeng Gao
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, China.
| | - Xiang Qin
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, China.
| | - Xu Zhang
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, China. -
| | - Huaiguo Xue
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, China.
| |
Collapse
|