1
|
Huang M, Ye L, Yu L, Zhang Y, Zeng T, Yang J, Tian F, Wu Z, Zhang X, Hu C, Yang N. Incorporation of laser-induced graphene with hierarchical NiCo layered double hydroxide nanosheets for electrochemical determination of glucose in food and serum. Anal Chim Acta 2024; 1329:343194. [PMID: 39396284 DOI: 10.1016/j.aca.2024.343194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2024] [Revised: 08/07/2024] [Accepted: 09/02/2024] [Indexed: 10/15/2024]
Abstract
Dependable and sensitive glucose (Glu) testing in foodstuff and blood serum is highly desirable to prevent and treat diabetes. Electrochemical quantification of Glu has attracted great interests due to the advantages, including simple operation, higher sensitivity, easy miniaturization, ease of on-site and wearable detection as well as fast response. High costs and environmental dependence of enzymes pose a challenge to the electrochemical enzymatic biosensors. Nonenzymatic electrochemical Glu sensors are urgently needed to aid the Glu detection in human serum and food samples. To fabricate flexible Glu electrochemical sensors, designing suitable electrode substrate and efficient electrocatalyst is of paramount significance. Herein, the porous patterned laser-induced graphene (LIG) was fabricated on polyimide substrates through an efficient laser-inducing technology, and then used directly as the electrode substrate. Electrochemical deposition of NiCo layered double hydroxide (LDH) nanoflakes on the LIG surface was then conducted to achieve NiCo-LDH/LIG electrode as a Glu sensor. Under optimal conditions, this sensor displays a low detection limit of 0.05 μM. Two sets of broad detection linear ranges were found to be from 0.5 to 270 μM and from 0.27 to 3.6 mM, with high sensitivities of 9.750 μA μM-1 cm-2 and 3.760 μA μM-1 cm-2, respectively. The enhanced performance was ascribed to the cooperative action of NiCo-LDH and LIG, in which porous LIG provides extraordinary electroconductibility and a high surface area, while NiCo-LDH offers numerous exposed active sites and outstanding electrocatalytic performance. Practical application was further verified during the Glu detection in human serum and food samples. This research confirms that the NiCo-LDH/LIG composite is a prospective electrode for high-performance Glu sensor and provides a way of developing nonenzymatic electrochemical sensors to analyze the Glu in human serum and food samples, opening new avenues in electrochemical sensing.
Collapse
Affiliation(s)
- Man Huang
- School of Chemistry and Environmental Engineering, School of Materials Science and Engineering, Key Laboratory of Green Chemical Engineering Process of Ministry of Education, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430205, China
| | - Lei Ye
- School of Chemistry and Environmental Engineering, School of Materials Science and Engineering, Key Laboratory of Green Chemical Engineering Process of Ministry of Education, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430205, China
| | - Liwen Yu
- School of Chemistry and Environmental Engineering, School of Materials Science and Engineering, Key Laboratory of Green Chemical Engineering Process of Ministry of Education, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430205, China
| | - Yuanyuan Zhang
- School of Chemistry and Environmental Engineering, School of Materials Science and Engineering, Key Laboratory of Green Chemical Engineering Process of Ministry of Education, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430205, China.
| | - Ting Zeng
- School of Chemistry and Environmental Engineering, School of Materials Science and Engineering, Key Laboratory of Green Chemical Engineering Process of Ministry of Education, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430205, China
| | - Juan Yang
- School of Chemistry and Environmental Engineering, School of Materials Science and Engineering, Key Laboratory of Green Chemical Engineering Process of Ministry of Education, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430205, China
| | - Fan Tian
- School of Chemistry and Environmental Engineering, School of Materials Science and Engineering, Key Laboratory of Green Chemical Engineering Process of Ministry of Education, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430205, China
| | - Zhen Wu
- Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials, Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, China
| | - Xiuhua Zhang
- Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials, Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, China
| | - Chengguo Hu
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Nianjun Yang
- Department of Chemistry & IMO-IMOMEC, Hasselt University Diepenbeek, 3590, Belgium
| |
Collapse
|
2
|
Jing X, Liu JM, Wang S. Emerging Nano/Microporous Architectures for Food Hazards: New Strategies for Precise Inspection and New Principles for Controllable Regulation. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2024; 72:18794-18808. [PMID: 39160142 DOI: 10.1021/acs.jafc.4c05300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/21/2024]
Abstract
The big progress of materials science along with chemical engineering and biotechnology has significantly promoted interdisciplinary development, achieving advanced analytical methodologies, improved inspection performance, as well as promising regulation principles for food safety. The very recent progress on nano/microporous architectures for agri-food science, including new strategies for precise inspection and new principles for controllable regulation of food hazards, are summarized and discussed. Major attention is paid to the newly emerged porous architectures with their derivative nano/microstructures contributing to food safety through their instinctive advantages including special material surface, extraordinary porous structure, ease-of-modification, and excellent diversity and variability. This review clearly and logically displays the research road maps and development trends for current food safety issues and give suggestive directions for future outlook as well as the bottleneck problems to be solved, not only smart inspection and analysis but also elimination and control of ever-emerging food hazards.
Collapse
Affiliation(s)
- Xu Jing
- College of Food Science and Engineering, Shanxi Agricultural University, Taigu, Shanxi 030801, Peoples R China
| | - Jing-Min Liu
- Tianjin Key Laboratory of Food Science and Health, School of Medicine, Nankai University, Tianjin 300071, Peoples R China
| | - Shuo Wang
- College of Food Science and Engineering, Shanxi Agricultural University, Taigu, Shanxi 030801, Peoples R China
- Tianjin Key Laboratory of Food Science and Health, School of Medicine, Nankai University, Tianjin 300071, Peoples R China
| |
Collapse
|
3
|
Zhang S, Wang M, Wang X, Song J, Yang X. Electrocatalysis in MOF Films for Flexible Electrochemical Sensing: A Comprehensive Review. BIOSENSORS 2024; 14:420. [PMID: 39329795 PMCID: PMC11430114 DOI: 10.3390/bios14090420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2024] [Revised: 08/25/2024] [Accepted: 08/26/2024] [Indexed: 09/28/2024]
Abstract
Flexible electrochemical sensors can adhere to any bendable surface with conformal contact, enabling continuous data monitoring without compromising the surface's dynamics. Among various materials that have been explored for flexible electronics, metal-organic frameworks (MOFs) exhibit dynamic responses to physical and chemical signals, offering new opportunities for flexible electrochemical sensing technologies. This review aims to explore the role of electrocatalysis in MOF films specifically designed for flexible electrochemical sensing applications, with a focus on their design, fabrication techniques, and applications. We systematically categorize the design and fabrication techniques used in preparing MOF films, including in situ growth, layer-by-layer assembly, and polymer-assisted strategies. The implications of MOF-based flexible electrochemical sensors are examined in the context of wearable devices, environmental monitoring, and healthcare diagnostics. Future research is anticipated to shift from traditional microcrystalline powder synthesis to MOF thin-film deposition, which is expected to not only enhance the performance of MOFs in flexible electronics but also improve sensing efficiency and reliability, paving the way for more robust and versatile sensor technologies.
Collapse
Affiliation(s)
- Suyuan Zhang
- Sinopec (Shanghai) Research Institute of Petrochemical Technology Co., Ltd., Shanghai 201210, China
| | - Min Wang
- School of Life Sciences, Shanghai University, Shanghai 200444, China
| | - Xusheng Wang
- School of Materials Science and Engineering, Zhejiang Sci-Tech University, Hangzhou 310018, China
| | - Jun Song
- School of Life Sciences, Shanghai University, Shanghai 200444, China
| | - Xue Yang
- School of Life Sciences, Shanghai University, Shanghai 200444, China
| |
Collapse
|
4
|
Angizi S, Rahmati R, Hatamie A, Nobakht V, Simchi A. Two-Dimensional Nanorod-Shaped Co(II) Coordination Polymer on Three-Dimensional Metallic Foam: A Hybrid Platform for Electrochemical Oxidation of Glucose. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:17689-17698. [PMID: 39161300 DOI: 10.1021/acs.langmuir.4c02084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/21/2024]
Abstract
This study unveils a novel electrochemical biosensor for monitoring glucose in biological fluids by employing nanorods of a cobalt-bispyridyl/dicarboxylate framework grown in a layer-by-layer manner on a highly porous nickel substrate. The hybrid microporous system has a bicatalytic effect on glucose oxidation due to the synergistic catalytic impact of the nickel and cobalt ions with varying oxidation states as electroactive sites. In addition, the controlled growth of inorganic-organic frameworks changes the mechanism of electron transfer from a diffusion-controlled process to an adsorption-controlled process, thus yielding a low onset oxidation potential (∼0.21 V/Ag-AgCl) and a high current intensity (∼1 mA) for the oxidation of glucose in alkaline media. A fast response time (∼2 s) and a reasonably high sensitivity (0.14 μA μM-1) within a broad linear range (40-360 μM) have determined the suitability and superiority of the hybrid electrode for glucose monitoring compared to many metal-organic-based biosensors. The facile fabrication process of the Co(II) coordination polymer/Ni substrate with a large surface area that benefits from the synergetic catalytic activity of nickel-cobalt hybrids may pave the way for the development of novel hybrid electrodes for biosensors and direct glucose fuel cells.
Collapse
Affiliation(s)
- Shayan Angizi
- Department of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S4M1, Canada
| | - Reza Rahmati
- Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, Ontario M5S 3G8, Canada
| | - Amir Hatamie
- Department of Chemistry, Institute for Advanced Studies in Basic Science (IASBS), No. 444, Prof. Yousef Sobouti Boulevard, Zanjan 45137-66731, Iran
- University of Gothenburg, Department of Chemistry and Molecular Biology, Kemivägen 10, 412 96 Gothenburg, Sweden
| | - Valiollah Nobakht
- Department of Chemistry, Faculty of Science, Shahid Chamran University of Ahvaz, Ahvaz 6135743135, Iran
| | - Abdolreza Simchi
- Fraunhofer Institute for Manufacturing Technology and Advanced Materials, 28359 Bremen, Germany
| |
Collapse
|
5
|
Jin Y, Yuan X, Ou L, Wu J, Hu J, Xue K, Xiong X. In situ fast self-assembled preparation of dandelion-like Cu(OH) 2@Cu 3(HHTP) 2 with core-shell heterostructure arrays for electrochemical sensing of formaldehyde in food samples. Food Chem 2024; 447:139013. [PMID: 38507950 DOI: 10.1016/j.foodchem.2024.139013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 02/05/2024] [Accepted: 03/10/2024] [Indexed: 03/22/2024]
Abstract
Formaldehyde is known to harm the respiratory, nervous, and digestive systems of people. In this paper, a novel dandelion-like electrocatalyst with core-shell heterostructure arrays were fast self-assembled prepared in situ using copper foam (CF) as support substrate and 2,3,6,7,10,11 hexahydroxy-triphenyl (HHTP) as ligand (Cu(OH)2@Cu3(HHTP)2/CF) by a simple two-step hydrothermal reaction. The 1D Cu(OH)2 nanorods "core" and the 2D π-conjugated conducting metal-organic frameworks (Cu3(HHTP)2cMOF) "shell" with remote delocalized electrons give the dandelion-like heterogeneous catalysts excellent electrochemical activity such as a large specific surface area, high conductivity and a fast electron transfer rate. The Cu(OH)2@Cu3(HHTP)2/CF exhibited excellent electrocatalytic performance for formaldehyde under alkaline conditions with a linear range of 0.2 μmol/L - 125 μmol/L and 125 μmol/L - 8 mmol/L, a detection limit as low as 15.9 nmol/L (S/N = 3), as well as good accuracy, consistency, and durability, and it effectively identified FA in food.
Collapse
Affiliation(s)
- Yao Jin
- College of Chemistry and Material Science, Key Laboratory of the Evaluation and Monitoring of Southwest Land Resources (Ministry of Education), Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Xiangwei Yuan
- College of Chemistry and Material Science, Key Laboratory of the Evaluation and Monitoring of Southwest Land Resources (Ministry of Education), Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Lian Ou
- College of Chemistry and Material Science, Key Laboratory of the Evaluation and Monitoring of Southwest Land Resources (Ministry of Education), Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Jiaying Wu
- College of Chemistry and Material Science, Key Laboratory of the Evaluation and Monitoring of Southwest Land Resources (Ministry of Education), Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Jiangtao Hu
- Technology Center of Chengdu Customs, Chengdu 610041, Sichuan, China; Food Safety Detection Key Laboratory of Sichuan Province, Chengdu 610041, Sichuan, China
| | - Kang Xue
- Technology Center of Chengdu Customs, Chengdu 610041, Sichuan, China; Food Safety Detection Key Laboratory of Sichuan Province, Chengdu 610041, Sichuan, China.
| | - Xiaoli Xiong
- College of Chemistry and Material Science, Key Laboratory of the Evaluation and Monitoring of Southwest Land Resources (Ministry of Education), Sichuan Normal University, Chengdu, Sichuan 610068, China.
| |
Collapse
|
6
|
Shubhangi, Divya, Rai SK, Chandra P. Shifting paradigm in electrochemical biosensing matrices comprising metal organic frameworks and their composites in disease diagnosis. WILEY INTERDISCIPLINARY REVIEWS. NANOMEDICINE AND NANOBIOTECHNOLOGY 2024; 16:e1980. [PMID: 38973017 DOI: 10.1002/wnan.1980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Revised: 05/15/2024] [Accepted: 05/22/2024] [Indexed: 07/09/2024]
Abstract
Metal Organic Frameworks (MOFs) are an evolving category of crystalline microporous materials that have grabbed the research interest for quite some time due to their admirable physio-chemical properties and easy fabrication methods. Their enormous surface area can be a working ground for innumerable molecular adhesions and site for potential sensor matrices. They have been explored in the last decade for incorporation in electrochemical sensor matrices as diagnostic solutions for a plethora of diseases. This review emphasizes on some of the recent advancements in the area of MOF-based electrochemical biosensors with focus on various important diseases and their significance in upgrading the sensor performance. It summarizes MOF-based biosensors for monitoring biomarkers relevant to diabetes, viral and bacterial sepsis infections, neurological disorders, cardiovascular diseases, and cancer in a wide range of real matrices. The discussion has been supplemented with extensive tables elaborating recent trends in the field of MOF-composite probe fabrication strategies with their respective sensing parameters. The article sums up the future scope of these materials in the field of biosensors and enlightens the reader with recent trends for future research scope. This article is categorized under: Diagnostic Tools > Biosensing Diagnostic Tools > Diagnostic Nanodevices.
Collapse
Affiliation(s)
- Shubhangi
- School of Biomedical Engineering, Indian Institute of Technology Laboratory (BHU) Varanasi, Varanasi, Uttar Pradesh, India
- Laboratory of Bio-Physio Sensors and Nanobioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| | - Divya
- Laboratory of Bio-Physio Sensors and Nanobioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| | - Sanjay K Rai
- School of Biomedical Engineering, Indian Institute of Technology Laboratory (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| | - Pranjal Chandra
- Laboratory of Bio-Physio Sensors and Nanobioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| |
Collapse
|
7
|
Wang F, Hu J, Wu X, Yuan G, Su Y, Fan Z, Xue H, Pang H. Streamlined synthesis of superstructure Ni-benzimidazole MOFs: Glucose electrochemical analysis. J Colloid Interface Sci 2024; 665:764-771. [PMID: 38554466 DOI: 10.1016/j.jcis.2024.03.174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Revised: 03/12/2024] [Accepted: 03/26/2024] [Indexed: 04/01/2024]
Abstract
The design and synthesis of efficient electrochemical sensors are crucial transformation technologies in electrochemistry. We successfully synthesize a three-dimensional Ni-metal-organic framework (MOF) nanostructured material with a superior architecture using benzimidazole and nickel nitrate as precursors at room temperature which is being applied in glucose electrochemical sensors. The reaction mechanism of M-6 during glucose detection is thoroughly studied using various characterization techniques, such as in situ Raman spectroscopy, in situ ultraviolet-visible spectrophotometry, synchrotron radiography, X-ray diffraction, X-ray photoelectron spectroscopy, and scanning electron microscopy. The research findings demonstrate that the M-6 material exhibits high sensitivity for glucose detection, with a sensitivity of 2199.88 mA M-1 cm-2. This study provides an important reference for designing more efficient electrochemical reaction systems and optimizing material performance. Furthermore, the superstructural design offers new ideas and possibilities for the development and application of similar materials.
Collapse
Affiliation(s)
- Fang Wang
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225009, Jiangsu, PR China; School of Chemical Engineering, Yangzhou Polytechnology Institute, Yangzhou 225127, PR China
| | - Jinliang Hu
- Science and Technology Innovation Center, Institution Jiangsu Yangnong Chemical Group Co. Ltd., Yangzhou 225009, PR China
| | - Xiaohui Wu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225009, Jiangsu, PR China
| | - Guoqiang Yuan
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225009, Jiangsu, PR China
| | - Yichun Su
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225009, Jiangsu, PR China
| | - Ziheng Fan
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225009, Jiangsu, PR China
| | - Huaiguo Xue
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225009, Jiangsu, PR China
| | - Huan Pang
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225009, Jiangsu, PR China.
| |
Collapse
|
8
|
Cheng L, Zheng W, Zhang YN, Li X, Zhao Y. In Situ Measurement of Urea Concentration With an In-Fiber SPR-MZI Sensor. IEEE Trans Nanobioscience 2024; 23:403-409. [PMID: 38722715 DOI: 10.1109/tnb.2024.3398807] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/02/2024]
Abstract
A fiber-optic urea sensor based on surface plasmon resonance (SPR) and Mach-Zehnder interference (MZI) combined principle was designed and implemented. By plating gold film on the single-mode-no-core-thin-core-single-mode fiber structure, we successfully excited both SPR and MZI, and constructed two parallel detection channels for simultaneously measurement of urea concentration and temperature. Urease was immobilized on the gold film by metal-organic zeolite skeleton (ZIF-8), which can not only fix a large number of urease to improve measurement sensitivity of urea, but also protect urease activity to ensure the sensor stability. Experimental results indicate that the designed urea sensor with temperature compensation function can detect urea solution with concentration of 1-9 mM, and the sensitivity is 1.4 nm/mM. The proposed measurement method provides a new choice for monitoring urea concentration in the field of medical diagnosis and human health monitoring.
Collapse
|
9
|
Zhu R, Song Y, Hu J, Zhu K, Liu L, Jiang Y, Xie L, Pang H. Conductive Metal-Organic Framework Grown on the Nickel-Based Hydroxide to Realize High-Performance Electrochemical Glucose Sensing. Chemistry 2024; 30:e202400982. [PMID: 38533890 DOI: 10.1002/chem.202400982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2024] [Revised: 03/27/2024] [Accepted: 03/27/2024] [Indexed: 03/28/2024]
Abstract
Glucose holds significant importance in disease diagnosis as well as beverage quality monitoring. The high-efficiency electrochemical sensor plays a crucial role in the electrochemical conversion technology. Ni(OH)2 nanosheets are provided with high specific surface area and redox activity that are widely used in electrochemistry. Conductive metal-organic frameworks (cMOFs) perfectly combine the structural controllability of organic materials with the long-range ordering of inorganic materials that possess the characteristic of high electron mobility. Based on the above considerations, the combination of Ni(OH)2 and Ni-HHTP (HHTP=2,3,6,7,10,11-hexahydroxytriphenylene) as an electrode modification material is designed to enhance electrochemical performance. In this work, to improve glucose detection, a sequence of Ni(OH)2@NiCo-HHTP and NiM-LDH@Ni-HHTP (M=Co2+, Mn2+, Cu2+, LDH=layered double hydroxide) are successfully synthesised by doping metals into Ni-HHTP and Ni(OH)2, respectively. As a result, NiCu-LDH@Ni-HHTP showed the best excellent glucose detection sensitivity.
Collapse
Affiliation(s)
- Rongmei Zhu
- School of Chemistry and Chemical Engineering, Institute for Innovative Materials and Energy, Yangzhou University, Yangzhou, Jiangsu 225009, P. R. China
| | - Yongzhen Song
- School of Chemistry and Chemical Engineering, Institute for Innovative Materials and Energy, Yangzhou University, Yangzhou, Jiangsu 225009, P. R. China
| | - Jinliang Hu
- Jiangsu Yangnong Chemical Group Co. Ltd., Yangzhou, 225009, P. R. China
| | - Keda Zhu
- School of Chemistry and Chemical Engineering, Institute for Innovative Materials and Energy, Yangzhou University, Yangzhou, Jiangsu 225009, P. R. China
| | - Limei Liu
- School of Chemistry and Chemical Engineering, Institute for Innovative Materials and Energy, Yangzhou University, Yangzhou, Jiangsu 225009, P. R. China
| | - Yuxuan Jiang
- School of Chemistry and Chemical Engineering, Institute for Innovative Materials and Energy, Yangzhou University, Yangzhou, Jiangsu 225009, P. R. China
| | - Liru Xie
- School of Chemistry and Chemical Engineering, Institute for Innovative Materials and Energy, Yangzhou University, Yangzhou, Jiangsu 225009, P. R. China
| | - Huan Pang
- School of Chemistry and Chemical Engineering, Institute for Innovative Materials and Energy, Yangzhou University, Yangzhou, Jiangsu 225009, P. R. China
| |
Collapse
|
10
|
Li B, Xie X, Meng T, Guo X, Li Q, Yang Y, Jin H, Jin C, Meng X, Pang H. Recent advance of nanomaterials modified electrochemical sensors in the detection of heavy metal ions in food and water. Food Chem 2024; 440:138213. [PMID: 38134834 DOI: 10.1016/j.foodchem.2023.138213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Revised: 12/10/2023] [Accepted: 12/12/2023] [Indexed: 12/24/2023]
Abstract
As one of the main pollutants, heavy metal ions can accumulate in the human body and cause a cascade of damage. Electrochemical sensors provide great prospects for tracing heavy metal ions because of their properties of high sensitivity, low detection limits and fast response. Electrode surface modification materials play a key role in enhancing the performance of electrochemical sensors. Herein, we summarize in detail the recent work on electrochemical sensors modified by carbon nanomaterials (graphene and its derivatives, carbon nanofibers and carbon nanotubes), metal nanomaterials (gold, silver, bismuth and iron), complexes (MOFs, ZIFs and MXenes) and their composites for the detection of heavy metal ions (mainly include Cd(II), Hg(II), Pb(II), As(III), Cu(II) and Zn(II)) in food and water. The synthetic strategies, mechanisms, innovations, advantages, challenges and prospects of various electrode modification nanomaterials for the detection of heavy metal ions in food and water are discussed.
Collapse
Affiliation(s)
- Bing Li
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China; College of Food Science and Engineering, Yangzhou University, Yangzhou 225127, Jiangsu, PR China.
| | - Xiaomei Xie
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China
| | - Tonghui Meng
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China
| | - Xiaotian Guo
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China
| | - Qingzheng Li
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China
| | - Yuting Yang
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China
| | - Haixia Jin
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China
| | - Changhai Jin
- College of Food Science and Engineering, Yangzhou University, Yangzhou 225127, Jiangsu, PR China
| | - Xiangren Meng
- College of Tourism and Culinary Science, Yangzhou University, Jiangsu 225127, PR China.
| | - Huan Pang
- College of Chemistry and Chemical Engineering, Yangzhou University, Jiangsu, 225002, PR China.
| |
Collapse
|
11
|
He L, Su J, You T, Xiao S, Huang P, He D, Jiang P. Rapid and facile preparation of NiFe-layered double hydroxide nanosheets as self-supported electrode for glucose detection in drink sample. Food Chem 2024; 439:138163. [PMID: 38091783 DOI: 10.1016/j.foodchem.2023.138163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 12/01/2023] [Accepted: 12/05/2023] [Indexed: 01/10/2024]
Abstract
Layered double hydroxides have been widely used for electrochemical glucose detection due to their layered structure with more active sites, but they suffer from lower electrical conductivity and long-time hydrothermal preparation. In this paper, NiFe-layered double hydroxide nanosheets supported on nickel foam (NiFe-LDH NSs/NF) was prepared using an ultrafast and facile method via in-situ corroding foam nickel in FeCl3 solution under room temperature, and the whole synthetic process can be accomplished within several minutes. The as-fabricated NiFe-LDH NSs/NF shows significant catalytic activity in the glucose oxidation, showing its great promise in glucose detection. As a self-supported electrode, NiFe-LDH NSs/NF is favorable for glucose detection, with a sensitivity of 9.79 and 3.29 mA mM-1 cm-2 within the linear range of 0.001 to 1.16 mM and 1.16 to 4.67 mM, respectively. Moreover, NiFe-LDH NSs/NF is also selective and reliable towards glucose detection in drink sample.
Collapse
Affiliation(s)
- Liu He
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Jiangyu Su
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Teng You
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Shuang Xiao
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Ping Huang
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Daiping He
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Ping Jiang
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China.
| |
Collapse
|
12
|
Tian Y, Xie L, Liu X, Geng Y, Wang J, Ma M. In situ synthesis of self-supporting conductive CuCo-based bimetal organic framework for sensitive nonenzymatic glucose sensing in serum and beverage. Food Chem 2024; 437:137875. [PMID: 37918160 DOI: 10.1016/j.foodchem.2023.137875] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 10/20/2023] [Accepted: 10/25/2023] [Indexed: 11/04/2023]
Abstract
Most MOFs are associated with the inherent defect of low conductivity, limiting their further application in electrochemical sensing. Herein, a self-supporting conductive CuCo-based bimetal organic framework with HHTP as the organic ligand was in situ synthesized on carbon cloth via a one-step hydrothermal method, namely CuCo-MOF/CC. Benefiting from the advantages of electrical conductivity and bimetallic synergies, CuCo-MOF/CC exhibited remarkable electrocatalytic performance toward glucose. Consequently, the prepared sensor demonstrated an outstanding sensitivity of 9317 μA mM-1 cm-2, a wide range of 0.25-2374.5 μM, a low determination limit (0.27 μM), and a rapid response time (1.6 s). The reproducibility, stability, and selectivity were also proved to be satisfactory. Furthermore, the remarkable feasibility of proposed sensor was confirmed in serum and beverages. With the convenience of the one-step hydrothermal method and portability of self-supporting electrode, CuCo-MOF/CC has emerged as a promising candidate for commercial glucose sensors.
Collapse
Affiliation(s)
- Yujie Tian
- College of Food Science and Engineering, Northwest A&F University, 22 Xinong Road, Yangling, 712100, Shaanxi, China
| | - Linxuan Xie
- College of Food Science and Engineering, Northwest A&F University, 22 Xinong Road, Yangling, 712100, Shaanxi, China
| | - Xin Liu
- College of Food Science and Engineering, Northwest A&F University, 22 Xinong Road, Yangling, 712100, Shaanxi, China
| | - Yanfei Geng
- College of Food Science and Engineering, Northwest A&F University, 22 Xinong Road, Yangling, 712100, Shaanxi, China
| | - Jianlong Wang
- College of Food Science and Engineering, Northwest A&F University, 22 Xinong Road, Yangling, 712100, Shaanxi, China
| | - Min Ma
- College of Food Science and Engineering, Northwest A&F University, 22 Xinong Road, Yangling, 712100, Shaanxi, China.
| |
Collapse
|
13
|
Cao W, Guo T, Wang J, Ding Y, Fan B, Liu D. Hierarchical N-doped porous carbon scaffold Cu/Co-oxide with enhanced electrochemical sensing properties for the detection of glucose in beverages and ascorbic acid in vitamin C tablets. Food Chem 2024; 436:137750. [PMID: 37862993 DOI: 10.1016/j.foodchem.2023.137750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 10/07/2023] [Accepted: 10/11/2023] [Indexed: 10/22/2023]
Abstract
This research focuses on the development of a highly efficient electrocatalyst, CuxO/NPC@Co3O4/NPC-10-7, for detecting glucose and ascorbic acid. In a 0.1 M NaOH solution, the modified electrode exhibits a sensitivity of 3314.29 μA mM-1 cm-2 for glucose detection. The linear range for ascorbic acid sensing is 0.5 μM - 23.332 mM, with a detection limit as low as 0.24 μM. In a 0.1 M PBS solution, the linear range for ascorbic acid detection extends to 43.328 mM, which represents the best performance reported to date by chronoamperometry. Moreover, the electrode demonstrates high accuracy, with a recovery rate of 96.80 % - 103.60 % for glucose detection and a recovery rate of 95.25 % - 104.83 % for ascorbic acid detection. These results suggest that the CuxO/NPC@Co3O4/NPC-10-7 modified electrode shows significant potential for practical applications in food detection.
Collapse
Affiliation(s)
- Wenbin Cao
- School of Chemistry and Environmental Engineering, Hubei Key Laboratory of Novel Reactor and Green Chemistry Technology, Wuhan Institute of Technology, Wuhan 430205, PR China
| | - Tong Guo
- School of Chemistry and Environmental Engineering, Hubei Key Laboratory of Novel Reactor and Green Chemistry Technology, Wuhan Institute of Technology, Wuhan 430205, PR China
| | - Jialiang Wang
- School of Chemistry and Environmental Engineering, Hubei Key Laboratory of Novel Reactor and Green Chemistry Technology, Wuhan Institute of Technology, Wuhan 430205, PR China
| | - Yigang Ding
- School of Chemistry and Environmental Engineering, Hubei Key Laboratory of Novel Reactor and Green Chemistry Technology, Wuhan Institute of Technology, Wuhan 430205, PR China
| | - Baoming Fan
- School of Materials and Mechanical Engineering, Key Laboratory of Processing and Quality Evaluation Technology of Green Plastics of China National Light Industry Council, Beijing Technology and Business University, Beijing 100048, PR China
| | - Dong Liu
- School of Chemistry and Environmental Engineering, Hubei Key Laboratory of Novel Reactor and Green Chemistry Technology, Wuhan Institute of Technology, Wuhan 430205, PR China; School of Materials and Mechanical Engineering, Key Laboratory of Processing and Quality Evaluation Technology of Green Plastics of China National Light Industry Council, Beijing Technology and Business University, Beijing 100048, PR China.
| |
Collapse
|
14
|
Zhu C, Ren C, Jiang W, Liu D, Huang Y, Wang W, Chang K, Zhu L, Wang Q. A versatile SERS platform based on conductive MOF-enforced carbon paper for rapidly and sensitively monitoring diazepam in aquatic products. Food Chem 2024; 435:137608. [PMID: 37788540 DOI: 10.1016/j.foodchem.2023.137608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 09/06/2023] [Accepted: 09/25/2023] [Indexed: 10/05/2023]
Abstract
Herein, a versatile surface enhanced Raman scattering (SERS) platform was firstly constructed by integrating conductive metal organic framework (CMOF) with controlled electrodeposition of Au nanoparticles (Au NPs) on flexible carbon paper (CP-CMOF@Au) for sensitively recognizing diazepam (DZP) in aquatic products. The CMOF not only provided a pre-concentration effect for boosting sensitivity, but also dramatically improved the intrinsic electrical conductivity contributing to homogeneous distribution of Au NPs and forming SERS-active "hot spot" with superior stability and reproducibility. Based on CP-CMOF@Au chip, DZP can be sensitively detected with low limit of detection of 0.64 ng mL-1 and wide linear detection range from 0.001 to 10 μg mL-1. Also, DZP in aquatic products can be collected and recognized using multiple approaches (drip coating, soaking and wiping) with excellent reusability and satisfactory recovery of 85.8-103.3%. This method would provide an ingenious SERS strategy for rapidly monitoring DZP in aquatic products with good practical applicability.
Collapse
Affiliation(s)
- Chengke Zhu
- Key Laboratory of Freshwater Fish Reproduction and Development (Ministry of Education), Key Laboratory of Aquatic Science of Chongqing, College of Fisheries, Southwest University, Chongqing 400715, China
| | - Chaoying Ren
- Key Laboratory of Freshwater Fish Reproduction and Development (Ministry of Education), Key Laboratory of Aquatic Science of Chongqing, College of Fisheries, Southwest University, Chongqing 400715, China
| | - Wenshan Jiang
- Key Laboratory of Food Nutrition and Healthy in Universities of Shandong, College of Food Science and Engineering, Shandong Agricultural University, Tai'an, Shandong 271018, China
| | - Dan Liu
- Key Laboratory of Freshwater Fish Reproduction and Development (Ministry of Education), Key Laboratory of Aquatic Science of Chongqing, College of Fisheries, Southwest University, Chongqing 400715, China
| | - Yiyang Huang
- Key Laboratory of Freshwater Fish Reproduction and Development (Ministry of Education), Key Laboratory of Aquatic Science of Chongqing, College of Fisheries, Southwest University, Chongqing 400715, China
| | - Wenjie Wang
- Key Laboratory of Freshwater Fish Reproduction and Development (Ministry of Education), Key Laboratory of Aquatic Science of Chongqing, College of Fisheries, Southwest University, Chongqing 400715, China
| | - Kuan Chang
- Key Laboratory of Food Nutrition and Healthy in Universities of Shandong, College of Food Science and Engineering, Shandong Agricultural University, Tai'an, Shandong 271018, China
| | - Long Zhu
- College of Marine Science and Fisheries, Jiangsu Ocean University, Lianyungang, Jiangsu 222005, China
| | - Qinzhi Wang
- Key Laboratory of Food Nutrition and Healthy in Universities of Shandong, College of Food Science and Engineering, Shandong Agricultural University, Tai'an, Shandong 271018, China.
| |
Collapse
|
15
|
Xu Y, Ben Y, Sun L, Su J, Guo H, Zhou R, Wei Y, Wei Y, Lu Y, Sun Y, Zhang X. Sensing platform for the highly sensitive detection of catechol based on composite coupling with conductive Ni 3(HITP) 2 and nanosilvers. Phys Chem Chem Phys 2024; 26:2951-2962. [PMID: 38214187 DOI: 10.1039/d3cp05391a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2024]
Abstract
Catechol, which has a high toxicity and low degradability, poses significant risks to both human health and the environment. Tracking of catechol residues is essential to protect human health and to assess the safety of the environment. We constructed sensing platforms to detect catechol based on the conductive metal-organic frameworks [Ni3(HITP)2] and their nanosilver composites. The reduction process of catechol at the Ni3(HITP)2/AgNP electrode is chemically irreversible as a result of the difference in compatibility of the oxidation stability and conductivity between the Ni3(HITP)2/AgNS and Ni3(HITP)2/AgNP electrodes. The electrochemical results show that the Ni3(HITP)2/AgNS electrode presents a lower detection limit of 0.053 μM and better sensitivity, reproducibility and repeatability than the Ni3(HITP)2/AgNP electrode. The kinetic mechanism of the catechol electrooxidation at the surface of the electrode is controlled by diffusion through a 2H+/2e- process. The transfer coefficient is the key factor used to illustrate this process. During the electrochemical conversion of phenol to ketone, more than half of ΔG is used to change the activation energy. We also studied the stability, anti-interference and reproducibility of these electrode systems.
Collapse
Affiliation(s)
- Yuandong Xu
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China.
| | - Yingying Ben
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China.
| | - Lili Sun
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China.
| | - Jishan Su
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China.
| | - Hui Guo
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China.
| | - Rongjia Zhou
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China.
| | - Yaqing Wei
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China.
| | - Yajun Wei
- School of Chemical Engineering, Northwest Minzu University, Lanzhou 730030, China
| | - Yongjuan Lu
- School of Chemical Engineering, Northwest Minzu University, Lanzhou 730030, China
| | - Yizhan Sun
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China.
| | - Xia Zhang
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou 450001, China.
| |
Collapse
|
16
|
Gao F, Zhao Y, Dai X, Xu W, Zhan F, Liu Y, Wang Q. Aptamer tuned nanozyme activity of nickel-metal-organic framework for sensitive electrochemical aptasensing of tetracycline residue. Food Chem 2024; 430:137041. [PMID: 37527574 DOI: 10.1016/j.foodchem.2023.137041] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 07/18/2023] [Accepted: 07/26/2023] [Indexed: 08/03/2023]
Abstract
It is urgently needed to develop high-performance method for tetracycline (TC) analysis to meet the growing concerns about food safety. Herein, a MOF of Ni2+-2,3,6,7,10,11-hexahydroxytriphenylene (Ni-HHTP) with peroxidase activity has been prepared and coated on a screen printing electrode, followed by non-covalent adsorption of tetracycline aptamer (TC-Apt) through the π-stacking. The spectroscopic and electrochemical assays show that TC-Apt can effectively enhance the nanozyme activity of Ni-HHTP using 3,3',5,5'-tetramethylbenzidine (TMB)/H2O2 as the probe. Upon binding with TC, the configuration of TC-Apt is changed and desorbs from the Ni-HHTP, resulting in the decrease of the nanozyme activity of aptasensor. Based on this principle, the target TC can be analyzed in concentrations ranging from 10 pM to 1.0 μM, with a detection limit of 1.9 pM. The aptsensor is also applicable for TC analysis in fresh Ctenopharyngodon idella meat and milk, which provides a new approach for TC residue monitoring in food.
Collapse
Affiliation(s)
- Feng Gao
- The Department of Chemistry and Environment Science, Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, Minnan Normal University, Zhangzhou 363000, China
| | - Yanan Zhao
- The Department of Chemistry and Environment Science, Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, Minnan Normal University, Zhangzhou 363000, China
| | - Xiaohui Dai
- Zhangzhou Products Quality Supervision Institute, Zhangzhou 363000, China
| | - Wenjing Xu
- The Department of Chemistry and Environment Science, Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, Minnan Normal University, Zhangzhou 363000, China
| | - Fengping Zhan
- The Department of Chemistry and Environment Science, Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, Minnan Normal University, Zhangzhou 363000, China
| | - Yibin Liu
- Zhangzhou Products Quality Supervision Institute, Zhangzhou 363000, China
| | - Qingxiang Wang
- The Department of Chemistry and Environment Science, Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, Minnan Normal University, Zhangzhou 363000, China.
| |
Collapse
|
17
|
Govindaraj M, Srivastava A, Muthukumaran MK, Tsai PC, Lin YC, Raja BK, Rajendran J, Ponnusamy VK, Arockia Selvi J. Current advancements and prospects of enzymatic and non-enzymatic electrochemical glucose sensors. Int J Biol Macromol 2023; 253:126680. [PMID: 37673151 DOI: 10.1016/j.ijbiomac.2023.126680] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 08/19/2023] [Accepted: 09/01/2023] [Indexed: 09/08/2023]
Abstract
This review discusses the most current developments and future perspectives in enzymatic and non-enzymatic glucose sensors, which have notably evolved over the preceding quadrennial period. Furthermore, a thorough exploration encompassed the sensor's intricate fabrication processes, the diverse range of materials employed, the underlying principles of detection, and an in-depth assessment of the sensors' efficacy in detecting glucose levels within essential bodily fluids such as human blood serums, urine, saliva, and interstitial fluids. It is worth noting that the accurate quantification of glucose concentrations within human blood has been effectively achieved by utilizing classical enzymatic sensors harmoniously integrated with optical and electrochemical transduction mechanisms. Monitoring glucose levels in various mediums has attracted exceptional attention from industrial to academic researchers for diabetes management, food quality control, clinical medicine, and bioprocess inspection. There has been an enormous demand for the creation of novel glucose sensors over the past ten years. Research has primarily concentrated on succeeding biocompatible and enhanced sensing abilities related to the present technologies, offering innovative avenues for more effective glucose sensors. Recent developments in wearable optical and electrochemical sensors with low cost, high stability, point-of-care testing, and online tracking of glucose concentration levels in biological fluids can aid in managing and controlling diabetes globally. New nanomaterials and biomolecules that can be used in electrochemical sensor systems to identify glucose concentration levels are developed thanks to advances in nanoscience and nanotechnology. Both enzymatic and non-enzymatic glucose electrochemical sensors have garnered much interest recently and have made significant strides in detecting glucose levels. In this review, we summarise several categories of non-enzymatic glucose sensor materials, including composites, non-precious transition metals and their metal oxides, hydroxides, precious metals and their alloys, carbon-based materials, conducting polymers, metal-organic framework (MOF)-based electrocatalysts, and wearable device-based glucose sensors deeply.
Collapse
Affiliation(s)
- Muthukumar Govindaraj
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India; Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan
| | - Ananya Srivastava
- Department of Chemistry, Institute of Science, Banaras Hindu University, Varanasi 221005, India
| | - Magesh Kumar Muthukumaran
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India
| | - Pei-Chien Tsai
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan; Department of Computational Biology, Institute of Bioinformatics, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Chennai, Tamil Nadu, 602105, India
| | - Yuan-Chung Lin
- Institute of Environmental Engineering, National Sun Yat-sen University, Kaohsiung 804, Taiwan; Center for Emerging Contaminants Research, National Sun Yat-sen University, Kaohsiung 804, Taiwan.
| | - Bharathi Kannan Raja
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India
| | - Jerome Rajendran
- Department of Electrical Engineering and Computer Science, The University of California, Irvine, CA 92697, United States
| | - Vinoth Kumar Ponnusamy
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan; Center for Emerging Contaminants Research, National Sun Yat-sen University, Kaohsiung 804, Taiwan; Research Center for Precision Environmental Medicine, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan; Department of Medical Research, Kaohsiung Medical University Hospital (KMUH), Kaohsiung Medical University, Kaohsiung City 807, Taiwan; Department of Chemistry, National Sun Yat-sen University (NSYSU), Kaohsiung City 804, Taiwan.
| | - J Arockia Selvi
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India.
| |
Collapse
|
18
|
Al Murisi M, Al-Asheh S, Abdelkareem MA, Aidan A, Elsaid K, Olabi AG. In situ Growth of Zeolite Imidazole Frameworks (ZIF-67) on Carbon Cloth for the Application of Oxygen Reduction Reactions and Microbial Fuel Cells. ACS OMEGA 2023; 8:44514-44522. [PMID: 38046312 PMCID: PMC10688201 DOI: 10.1021/acsomega.3c02544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Accepted: 10/05/2023] [Indexed: 12/05/2023]
Abstract
Developing high surface area catalysts is an effective strategy to enhance the oxygen reduction reaction (ORR) in the application of microbial fuel cells (MFCs). This can be achieved by developing a catalyst based on metal-organic frameworks (MOFs) because they offer a porous active site for ORR. In this work, a novel in situ growth of 2D shell nanowires of ZIF-67 as a template for N-doped carbon (Co/NC) via a carbonization route was developed to enhance the ORR performance. The effects of different reaction times and different annealing temperatures were studied for a better ORR activity. The growth of the MOF template on the carbon cloth was confirmed using scanning electron microscopy, field emission scanning electron microscopy, transmission electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy, and Fourier transform infrared. The Co/NC-800 exhibited an enhancement in the ORR activity as evidenced by an onset potential and half-wave potential of 0.0 vs V Ag/AgCl and -0.1 vs V Ag/AgCl, respectively, with a limited current density exceeding the commercial Pt/C. Operating Co/NC-800 on MFC revealed a maximum power density of 30 ± 2.5 mW/m2, a maximum current density of 180 ± 2.5 mA/m2.
Collapse
Affiliation(s)
- Mohammed Al Murisi
- Department
of Chemical Engineering, American University
of Sharjah, P.O. Box 2666, Sharjah 26666,United Arab Emirates
| | - Sameer Al-Asheh
- Department
of Chemical Engineering, American University
of Sharjah, P.O. Box 2666, Sharjah 26666,United Arab Emirates
| | - Mohammad Ali Abdelkareem
- Department
of Sustainable and Renewable Energy Engineering, University of Sharjah, P.O. Box 27272, Sharjah27272,United Arab Emirates
| | - Ahmad Aidan
- Department
of Chemical Engineering, American University
of Sharjah, P.O. Box 2666, Sharjah 26666,United Arab Emirates
| | - Khaled Elsaid
- Chemical
Engineering Program, Texas A&M University
at Qatar, P.O. 23874, Doha23874,Qatar
| | - Abdul Ghani Olabi
- Department
of Sustainable and Renewable Energy Engineering, University of Sharjah, P.O. Box 27272, Sharjah27272,United Arab Emirates
| |
Collapse
|
19
|
Wang L, Guo GZ, Wang M, Ruan HY, Wu YP, Wu XQ, Zhang QC, Li DS. Ultrafast Response in Nonenzymatic Electrochemical Glucose Sensing with Ni(II)-MOFs by Dimensional Manipulation. Inorg Chem 2023; 62:16426-16434. [PMID: 37750677 DOI: 10.1021/acs.inorgchem.3c02107] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/27/2023]
Abstract
Metal-organic frameworks (MOFs) are emerging as promising candidates for electrochemical glucose sensing owing to their ordered channels, tunable chemistry, and atom-precision metal sites. Herein, the efficient nonenzymatic electrochemical glucose sensing is achieved by taking advantage of Ni(II)-based metal-organic frameworks (Ni(II)-MOFs) and acquiring the ever-reported fastest response time. Three Ni(II)-MOFs ({[Ni6L2(H2O)26]4H2O}n (CTGU-33), {Ni(bib)1/2(H2L)1/2(H2O)3}n (CTGU-34), {Ni(phen)(H2L)1/2(H2O)2}n (CTGU-35)) have been synthesized for the first time, which use benzene-1,2,3,4,5,6-hexacarboxylic acid (H6L) as an organic ligand and introduce 1,4-bis(1-imidazoly)benzene (bib) or 1,10-phenanthroline (phen) as spatially auxiliary ligands. Bib and phen convert the coordination mode of CTGU-33, affording structural dimensions from 2D of CTGU-33 to 3D of CTGU-34 or 1D of CTGU-35. By tuning the dimension of the skeleton, CTGU-34 with 3D interconnected channels exhibits an ultrafast response of less than 0.4 s, which is superior to the existing nonenzymatic electrochemical sensors. Additionally, a low detection limit of 0.12 μM (S/N = 3) and a high sensitivity of 1705 μA mM-1 cm-2 are simultaneously achieved. CTGU-34 further showcases desirable anti-interference and cycling stability, which demonstrates a promising application prospect in the real-time detection of glucose.
Collapse
Affiliation(s)
- Le Wang
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
- Hubei Three Gorges Laboratory, Yichang 443007, Hubei, P. R. China
| | - Gui-Zhi Guo
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
- Hanchuan Experimental Senior High School, Hanchuan 432300, Hubei, P. R. China
| | - Meidi Wang
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
- Hubei Three Gorges Laboratory, Yichang 443007, Hubei, P. R. China
| | - Heng-Yu Ruan
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
| | - Ya-Pan Wu
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
- Hubei Three Gorges Laboratory, Yichang 443007, Hubei, P. R. China
| | - Xue-Qian Wu
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
- Hubei Three Gorges Laboratory, Yichang 443007, Hubei, P. R. China
| | - Qi-Chun Zhang
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
| | - Dong-Sheng Li
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang 443002, Hubei, P. R. China
- Hubei Three Gorges Laboratory, Yichang 443007, Hubei, P. R. China
| |
Collapse
|
20
|
Zu S, Zhang H, Zhang T, Zhang M, Song L. Ni-Rh-based bimetallic conductive MOF as a high-performance electrocatalyst for the oxygen evolution reaction. Front Chem 2023; 11:1242672. [PMID: 37841204 PMCID: PMC10570521 DOI: 10.3389/fchem.2023.1242672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Accepted: 08/22/2023] [Indexed: 10/17/2023] Open
Abstract
Metal-organic frameworks (MOFs) have recently been considered the promising catalysts due to their merits of abundant metal sites, versatile coordination groups, and tunable porous structure. However, low electronic conductivity of most MOFs obstructs their direct application in electrocatalysis. In this work, we fabricate an Ni-Rh bimetallic conductive MOF ([Ni2.85Rh0.15(HHTP)2]n/CC) grown in situ on carbon cloth. Abundant nanopores in the conductive MOFs expose additional catalytic active sites, and the advantageous 2D π-conjugated structure helps accelerate charge transfer. Owing to the introduction of Rh, [Ni2.85Rh0.15(HHTP)2]n/CC exhibited substantially improved oxygen evolution reaction (OER) activity and exhibited only an overpotential of 320 mV to achieve the current density of 20 mA cm-2. The remarkable OER performance confirmed by the electrochemical tests could be ascribed to the synergistic effect caused by the doped Rh together with Ni in [Ni2.85Rh0.15(HHTP)2]n/CC, thereby exhibiting outstanding electrocatalytic performance.
Collapse
Affiliation(s)
| | | | | | | | - Li Song
- Jiangsu Collaborative Innovation Center of Atmospheric Environment, Jiangsu Key Laboratory of Atmospheric Environment Monitoring and Pollution Control, School of Environmental Science and Engineering, Nanjing University of Information Science and Technology, Nanjing, Jiangsu, China
| |
Collapse
|
21
|
Javanbakht S, Darvishi S, Dorchei F, Hosseini-Ghalehno M, Dehghani M, Pooresmaeil M, Suzuki Y, Ul Ain Q, Ruiz Rubio L, Shaabani A, Hayashita T, Namazi H, Heydari A. Cyclodextrin Host-Guest Recognition in Glucose-Monitoring Sensors. ACS OMEGA 2023; 8:33202-33228. [PMID: 37744789 PMCID: PMC10515351 DOI: 10.1021/acsomega.3c03746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2023] [Accepted: 08/23/2023] [Indexed: 09/26/2023]
Abstract
Diabetes mellitus is a prevalent chronic health condition that has caused millions of deaths worldwide. Monitoring blood glucose levels is crucial in diabetes management, aiding in clinical decision making and reducing the incidence of hypoglycemic episodes, thereby decreasing morbidity and mortality rates. Despite advancements in glucose monitoring (GM), the development of noninvasive, rapid, accurate, sensitive, selective, and stable systems for continuous monitoring remains a challenge. Addressing these challenges is critical to improving the clinical utility of GM technologies in diabetes management. In this concept, cyclodextrins (CDs) can be instrumental in the development of GM systems due to their high supramolecular recognition capabilities based on the host-guest interaction. The introduction of CDs into GM systems not only impacts the sensitivity, selectivity, and detection limit of the monitoring process but also improves biocompatibility and stability. These findings motivated the current review to provide a comprehensive summary of CD-based blood glucose sensors and their chemistry of glucose detection, efficiency, and accuracy. We categorize CD-based sensors into four groups based on their modification strategies, including CD-modified boronic acid, CD-modified mediators, CD-modified nanoparticles, and CD-modified functionalized polymers. These findings shed light on the potential of CD-based sensors as a promising tool for continuous GM in diabetes mellitus management.
Collapse
Affiliation(s)
- Siamak Javanbakht
- Research
Laboratory of Dendrimers and Natural Polymers, Faculty of Chemistry, University of Tabriz, P.O. Box 51666, Tabriz, Iran
| | - Sima Darvishi
- Faculty
of Chemistry, Khajeh Nasir Toosi University, Tehran, Iran
| | - Faeze Dorchei
- Polymer
Institute of the Slovak Academy of Sciences, Dúbravská cesta 9, 845 41 Bratislava, Slovakia
| | | | - Marjan Dehghani
- Department
of Chemistry, Shahid Bahonar University
of Kerman, Kerman 76169, Iran
| | - Malihe Pooresmaeil
- Research
Laboratory of Dendrimers and Natural Polymers, Faculty of Chemistry, University of Tabriz, P.O. Box 51666, Tabriz, Iran
| | - Yota Suzuki
- Department
of Materials and Life Sciences, Faculty of Science and Technology, Sophia University, 7-1, Kioi-cho, Chiyoda-ku, Tokyo 102-8554, Japan
- Graduate
School of Science and Engineering, Saitama
University, Saitama 338-8570, Japan
| | - Qurat Ul Ain
- Department
of Materials Engineering, School of Chemical and Materials Engineering, National University of Sciences and Technology, Islamabad H-12, Pakistan
| | - Leire Ruiz Rubio
- Macromolecular
Chemistry Group (LQM), Department of Physical Chemistry, Faculty of
Science and Technology, University of Basque
Country (UPV/EHU), Leioa 48940, Spain
- Basque
Centre for Materials, Applications and Nanostructures
(BCMaterials), UPV/EHU
Science Park, Leioa 48940, Spain
| | - Ahmad Shaabani
- Faculty
of Chemistry, Shahid Beheshti University, Tehran, Iran
| | - Takashi Hayashita
- Department
of Materials and Life Sciences, Faculty of Science and Technology, Sophia University, 7-1, Kioi-cho, Chiyoda-ku, Tokyo 102-8554, Japan
| | - Hassan Namazi
- Research
Laboratory of Dendrimers and Natural Polymers, Faculty of Chemistry, University of Tabriz, P.O. Box 51666, Tabriz, Iran
- Research
Center for Pharmaceutical Nanotechnology (RCPN), Tabriz University of Medical Science, Tabriz, Iran
| | - Abolfazl Heydari
- Polymer
Institute of the Slovak Academy of Sciences, Dúbravská cesta 9, 845 41 Bratislava, Slovakia
- National
Institute of Rheumatic Diseases, Nábrežie I. Krasku 4782/4, 921 12 Piešt’any, Slovakia
| |
Collapse
|
22
|
Sun G, Wei X, Zhang D, Huang L, Liu H, Fang H. Immobilization of Enzyme Electrochemical Biosensors and Their Application to Food Bioprocess Monitoring. BIOSENSORS 2023; 13:886. [PMID: 37754120 PMCID: PMC10526424 DOI: 10.3390/bios13090886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 09/07/2023] [Accepted: 09/11/2023] [Indexed: 09/28/2023]
Abstract
Electrochemical biosensors based on immobilized enzymes are among the most popular and commercially successful biosensors. The literature in this field suggests that modification of electrodes with nanomaterials is an excellent method for enzyme immobilization, which can greatly improve the stability and sensitivity of the sensor. However, the poor stability, weak reproducibility, and limited lifetime of the enzyme itself still limit the requirements for the development of enzyme electrochemical biosensors for food production process monitoring. Therefore, constructing sensing technologies based on enzyme electrochemical biosensors remains a great challenge. This article outlines the construction principles of four generations of enzyme electrochemical biosensors and discusses the applications of single-enzyme systems, multi-enzyme systems, and nano-enzyme systems developed based on these principles. The article further describes methods to improve enzyme immobilization by combining different types of nanomaterials such as metals and their oxides, graphene-related materials, metal-organic frameworks, carbon nanotubes, and conducting polymers. In addition, the article highlights the challenges and future trends of enzyme electrochemical biosensors, providing theoretical support and future perspectives for further research and development of high-performance enzyme chemical biosensors.
Collapse
Affiliation(s)
- Ganchao Sun
- School of Food Science and Engineering, Ningxia University, Yinchuan 750021, China; (G.S.); (X.W.)
| | - Xiaobo Wei
- School of Food Science and Engineering, Ningxia University, Yinchuan 750021, China; (G.S.); (X.W.)
| | - Dianping Zhang
- School of Mechanical Engineering, Ningxia University, Yinchuan 750021, China;
| | - Liben Huang
- Huichuan Technology (Zhuhai) Co., Ltd., Zhuhai 519060, China;
| | - Huiyan Liu
- School of Food Science and Engineering, Ningxia University, Yinchuan 750021, China; (G.S.); (X.W.)
| | - Haitian Fang
- School of Food Science and Engineering, Ningxia University, Yinchuan 750021, China; (G.S.); (X.W.)
| |
Collapse
|
23
|
Microplasma and quenching-induced Co doped NiMoO 4 nanorods with oxygen vacancies for electrochemical determination of glucose in food and serum. Food Chem 2023; 414:135755. [PMID: 36841101 DOI: 10.1016/j.foodchem.2023.135755] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 02/16/2023] [Accepted: 02/17/2023] [Indexed: 02/23/2023]
Abstract
In this paper, Co-doped NiMoO4 nanorods with oxygen vacancies are synthesized on carbon cloth (Co-NiMoO4 NRs/CC) via microplasma and quenching-induced method.Owing to the surface defects and metal ion doping, the electronic structure and surface properties of the catalyst are tuned.Cyclic voltammetry (CV) and amperometry are used to investigate the electrocatalytic behavior of the glucose sensor in an alkaline medium with sensitivities of 7411 and 3125 μA L mmol-1 cm-2 in the linear range 1.0 μmol L-1 to 1.0 mmol L-1 and 1.0 mmol L-1 to 7.0 mmol L-1, respectively. The detection limit is 0.079 μmol L-1 at S/N = 3. Moreover, the as-prepared catalyst electrode is also successfully used in real food and serum samples, with a recovery rate of 97.1%-107.4%.The DFT calculations show that the Co site of the catalyst significantly influenced glucose sensing performance. This idea expands the application of quenching chemistry in electrochemical sensing.
Collapse
|
24
|
Li Z, Zeng W, Li Y. Recent Progress in MOF-Based Electrochemical Sensors for Non-Enzymatic Glucose Detection. Molecules 2023; 28:4891. [PMID: 37446552 DOI: 10.3390/molecules28134891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2023] [Revised: 06/12/2023] [Accepted: 06/15/2023] [Indexed: 07/15/2023] Open
Abstract
In recent years, substantial advancements have been made in the development of enzyme-free glucose sensors utilizing pristine metal-organic frameworks (MOFs) and their combinations. This paper provides a comprehensive exploration of various MOF-based glucose sensors, encompassing monometallic MOF sensors as well as multi-metal MOF combinations. These approaches demonstrate improved glucose detection capabilities, facilitated by the augmented surface area and availability of active sites within the MOF structures. Furthermore, the paper delves into the application of MOF complexes and derivatives in enzyme-free glucose sensing. Derivatives incorporating carbon or metal components, such as carbon cloth synthesis, rGO-MOF composites, and core-shell structures incorporating noble metals, exhibit enhanced electrochemical performance. Additionally, the integration of MOFs with foams or biomolecules, such as porphyrins, enhances the electrocatalytic properties for glucose detection. Finally, this paper concludes with an outlook on the future development prospects of enzyme-free glucose MOF sensors.
Collapse
Affiliation(s)
- Ziteng Li
- College of Materials Science and Engineering, Chongqing University, Chongqing 400030, China
| | - Wen Zeng
- College of Materials Science and Engineering, Chongqing University, Chongqing 400030, China
| | - Yanqiong Li
- School of Electronic Information & Electrical Engineering, Chongqing University of Arts and Sciences, Chongqing 400030, China
| |
Collapse
|
25
|
Li P, Peng Y, Cai J, Bai Y, Li Q, Pang H. Recent Advances in Metal-Organic Frameworks (MOFs) and Their Composites for Non-Enzymatic Electrochemical Glucose Sensors. Bioengineering (Basel) 2023; 10:733. [PMID: 37370664 DOI: 10.3390/bioengineering10060733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 06/07/2023] [Accepted: 06/16/2023] [Indexed: 06/29/2023] Open
Abstract
In recent years, with pressing needs such as diabetes management, the detection of glucose in various substrates has attracted unprecedented interest from researchers in academia and industry. As a relatively new glucose sensor, non-enzymatic target detection has the characteristics of high sensitivity, good stability and simple manufacturing process. However, it is urgent to explore novel materials with low cost, high stability and excellent performance to modify electrodes. Metal-organic frameworks (MOFs) and their composites have the advantages of large surface area, high porosity and high catalytic efficiency, which can be utilized as excellent materials for electrode modification of non-enzymatic electrochemical glucose sensors. However, MOFs and their composites still face various challenges and difficulties that limit their further commercialization. This review introduces the applications and the challenges of MOFs and their composites in non-enzymatic electrochemical glucose sensors. Finally, an outlook on the development of MOFs and their composites is also presented.
Collapse
Affiliation(s)
- Panpan Li
- Guangling College, Yangzhou University, Yangzhou 225009, China
| | - Yi Peng
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225009, China
| | - Jinpeng Cai
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225009, China
| | - Yang Bai
- School of Pharmacy, Changzhou University, Changzhou 213164, China
- State Key Laboratory of Coordination Chemistry, Nanjing University, Nanjing 210008, China
| | - Qing Li
- Guangling College, Yangzhou University, Yangzhou 225009, China
| | - Huan Pang
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225009, China
| |
Collapse
|
26
|
Ma Y, Leng Y, Huo D, Zhao D, Zheng J, Yang H, Zhao P, Li F, Hou C. A sensitive enzyme-free electrochemical sensor based on a rod-shaped bimetallic MOF anchored on graphene oxide nanosheets for determination of glucose in huangshui. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:2417-2426. [PMID: 37183489 DOI: 10.1039/d2ay01977a] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
In this work, we propose a bimetallic Ni-Co based MOF attached to graphene oxide (GO) by a one-step hydrothermal approach which may be employed as an electrochemical enzyme-free glucose sensor. Due to the obvious synergistic catalysis of Ni and Co, as well as the combination of NiCo-MOF and GO, NiCo-MOF/GO not only enhances energy transfer and electrocatalytic performance but also provides a larger surface area and more active sites. Electrochemical studies show that NiCo-MOF/GO exhibits outstanding electrochemical activity, with a sensitivity of 11 177 μA mM-1 cm-2 and 4492 μA mM-1 cm-2 in the linear ranges of 1-497 μM and 597-3997 μM, a detection limit of 0.23 μM, and a response time of 2 seconds. More importantly, the newly fabricated sensor is successfully applied for glucose determination in huangshui. This method provides a novel strategy for the controlled fermentation process and product quality of Chinese baijiu.
Collapse
Affiliation(s)
- Yi Ma
- College of Biological Engineering, Sichuan University of Science and Engineering, 188 University Town, Yibin, China.
| | - Yinjiang Leng
- College of Biological Engineering, Sichuan University of Science and Engineering, 188 University Town, Yibin, China.
| | - Danqun Huo
- Chongqing Univ, Bioengn Coll, State & Local Joint Engn Lab Vasc Implants, Minist Educ, Key Lab Biorheol Sci & Technol, Chongqing, China.
| | - Dong Zhao
- Wuliangye Yibin Co., Ltd, Yibin, Sichuan, China
| | - Jia Zheng
- Wuliangye Yibin Co., Ltd, Yibin, Sichuan, China
| | - Huisi Yang
- Chongqing Univ, Bioengn Coll, State & Local Joint Engn Lab Vasc Implants, Minist Educ, Key Lab Biorheol Sci & Technol, Chongqing, China.
| | - Peng Zhao
- Chongqing Univ, Bioengn Coll, State & Local Joint Engn Lab Vasc Implants, Minist Educ, Key Lab Biorheol Sci & Technol, Chongqing, China.
| | - Feifeng Li
- College of Biological Engineering, Sichuan University of Science and Engineering, 188 University Town, Yibin, China.
| | - Changjun Hou
- College of Biological Engineering, Sichuan University of Science and Engineering, 188 University Town, Yibin, China.
- Chongqing Univ, Bioengn Coll, State & Local Joint Engn Lab Vasc Implants, Minist Educ, Key Lab Biorheol Sci & Technol, Chongqing, China.
| |
Collapse
|
27
|
Dong Q, Ling C, Zhao S, Tang X, Zhang Y, Xing Y, Yu H, Huang K, Zou Z, Xiong X. One-step rapid synthesis of Ni 0.5Co 0.5-CPO-27 nanorod array with oxygen vacancies based on DBD microplasma: As an effective non-enzymatic glucose sensor for beverage and human serum. Food Chem 2023; 407:135144. [PMID: 36493474 DOI: 10.1016/j.foodchem.2022.135144] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 11/26/2022] [Accepted: 11/30/2022] [Indexed: 12/03/2022]
Abstract
The rational design of high-efficiency catalysts for non-enzymatic glucose sensing is extremely important for the timely and effective monitoring of glucose content in beverages and human blood. A 3D bimetallic organic framework (Coordination Polymer of Oslo, CPO) nanorod array with oxygen vacancies was green fabricated on carbon cloth (Ni0.5Co0.5-CPO-27 NRA/CC) using dielectric barrier discharge (DBD) microplasma for the first time. Density functional theory (DFT) calculations demonstrated that the oxygen vacancy of Ni0.5Co0.5-CPO-27 can be effectively induced under DBD microplasma conditions. Based on the 3D nanorod arrays with rich oxygen vacancies and bimetallic synergistic effects, as a non-enzyme glucose sensor, the Ni0.5Co0.5-CPO-27 electrode exhibited a sensitivity of 8499.5 μA L/mmol cm-2 and 3239.2 μA L/mmol cm-2 and a limit of detection (LOD) of 0.16 μmol/L (S/N = 3). It has been successfully applied to the determination of glucose levels in real samples such as cola, green tea and human serum.
Collapse
Affiliation(s)
- Qiaoyan Dong
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Chengshuang Ling
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Shan Zhao
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Xin Tang
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Yu Zhang
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Yun Xing
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Huimin Yu
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Ke Huang
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Zhirong Zou
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China.
| | - Xiaoli Xiong
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, China.
| |
Collapse
|
28
|
Mao Y, Chen T, Hu Y, Son K. Ultra-thin 2D bimetallic MOF nanosheets for highly sensitive and stable detection of glucose in sweat for dancer. DISCOVER NANO 2023; 18:62. [PMID: 37382700 PMCID: PMC10409940 DOI: 10.1186/s11671-023-03838-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 03/27/2023] [Indexed: 06/30/2023]
Abstract
The measurement of glucose concentration in sweat is expected to replace the existing blood glucose detection, which realize the effective way of non-invasive monitoring of human glucose concentration in dancing. High precision glucose detection can be achieved by adjusting the electrode material of the sensor. Thus, in this work, the bimetallic organic frameworks (bi-MOFs) materials containing Mn and Ni ions (NiMn-MOF) with ultrathin nanosheets have been exquisitely designed. The ultrathin nanosheet and heterogeneous metal ions in the structure optimize the electronic structure, which improves the electrical conductivity of MOFs. The success of the preparation strategy leads the good electrocatalytic performance of NiMn-MOF for glucose detection. Detailedly, NiMn-MOF shows high sensitivity of 1576 μA mM-1 cm-2 in the linear range from 0 to 0.205 mM and the wide linear region of 0.255-2.655 mM and 3.655-5.655 mM were also observed. In addition, the high repeatability, reproductivity, long-term stability and ultra-low limited of detection (LOD, 0.28 μM, S/N = 3) provide foundation for the practical sensor application of this NiMn-MOF nanosheets. Remarkably, as designed NiMn-MOF sensor can accurately measure glucose in sweat showing great potential in the field of wearable glucose monitoring during dancing.
Collapse
Affiliation(s)
- Yufei Mao
- Department of Dance, Hanyang University, Seoul, 04763, Korea
| | - Tangchun Chen
- Department of Dance, Sichuan Conservatory of Music, Chengdu, 610500, China
| | - Yifan Hu
- Department of Music, Changshu Institute of Technology, Changshu, 215500, China
| | - KwanJung Son
- Department of Dance, Hanyang University, Seoul, 04763, Korea.
- Department of Dance, Sichuan Conservatory of Music, Chengdu, 610500, China.
- Department of Music, Changshu Institute of Technology, Changshu, 215500, China.
| |
Collapse
|
29
|
Liu M, Gao T, Li H, Xie B, Hu C, Guo Y, Xiao D. Preparation of amorphous Ni/Co bimetallic nanoparticles to enhance the electrochemical sensing of glucose. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/09/2023]
|
30
|
Sobahi N, Imran M, Khan ME, Mohammad A, Alam MM, Yoon T, Mehedi IM, Hussain MA, Abdulaal MJ, Jiman AA. Electrochemical Sensing of H 2O 2 by Employing a Flexible Fe 3O 4/Graphene/Carbon Cloth as Working Electrode. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2770. [PMID: 37049064 PMCID: PMC10096334 DOI: 10.3390/ma16072770] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 03/14/2023] [Accepted: 03/15/2023] [Indexed: 06/19/2023]
Abstract
We report the synthesis of Fe3O4/graphene (Fe3O4/Gr) nanocomposite for highly selective and highly sensitive peroxide sensor application. The nanocomposites were produced by a modified co-precipitation method. Further, structural, chemical, and morphological characterization of the Fe3O4/Gr was investigated by standard characterization techniques, such as X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscope (TEM) and high-resolution TEM (HRTEM), Fourier transform infrared (FTIR), and X-ray photoelectron spectroscopy (XPS). The average crystal size of Fe3O4 nanoparticles was calculated as 14.5 nm. Moreover, nanocomposite (Fe3O4/Gr) was employed to fabricate the flexible electrode using polymeric carbon fiber cloth or carbon cloth (pCFC or CC) as support. The electrochemical performance of as-fabricated Fe3O4/Gr/CC was evaluated toward H2O2 with excellent electrocatalytic activity. It was found that Fe3O4/Gr/CC-based electrodes show a good linear range, high sensitivity, and a low detection limit for H2O2 detection. The linear range for the optimized sensor was found to be in the range of 10-110 μM and limit of detection was calculated as 4.79 μM with a sensitivity of 0.037 µA μM-1 cm-2. The cost-effective materials used in this work as compared to noble metals provide satisfactory results. As well as showing high stability, the proposed biosensor is also highly reproducible.
Collapse
Affiliation(s)
- Nebras Sobahi
- Department of Electrical & Computer Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia; (M.M.A.)
| | - Mohd Imran
- Department of Chemical Engineering, College of Engineering, Jazan University, Jazan 45142, Saudi Arabia
| | - Mohammad Ehtisham Khan
- Department of Chemical Engineering Technology, College of Applied Industrial Technology (CAIT), Jazan University, Jazan 45142, Saudi Arabia
| | - Akbar Mohammad
- School of Chemical Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea;
| | - Md. Mottahir Alam
- Department of Electrical & Computer Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia; (M.M.A.)
| | - Taeho Yoon
- School of Chemical Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea;
| | - Ibrahim M. Mehedi
- Department of Electrical & Computer Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia; (M.M.A.)
- Center of Excellence in Intelligent Engineering Systems (CEIES), King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Mohammad A. Hussain
- Department of Electrical & Computer Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia; (M.M.A.)
| | - Mohammed J. Abdulaal
- Department of Electrical & Computer Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia; (M.M.A.)
| | - Ahmad A. Jiman
- Department of Electrical & Computer Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia; (M.M.A.)
| |
Collapse
|
31
|
Zhuang L, You Q, Su X, Chang Z, Ge M, Mei Q, Yang L, Dong W, Li L. High-Performance Detection of Exosomes Based on Synergistic Amplification of Amino-Functionalized Fe 3O 4 Nanoparticles and Two-Dimensional MXene Nanosheets. SENSORS (BASEL, SWITZERLAND) 2023; 23:3508. [PMID: 37050576 PMCID: PMC10099274 DOI: 10.3390/s23073508] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/14/2023] [Accepted: 03/20/2023] [Indexed: 06/19/2023]
Abstract
Exosomes derived from cancer cells have been recognized as a promising biomarker for minimally invasive liquid biopsy. Herein, a novel sandwich-type biosensor was fabricated for highly sensitive detection of exosomes. Amino-functionalized Fe3O4 nanoparticles were synthesized as a sensing interface with a large surface area and rapid enrichment capacity, while two-dimensional MXene nanosheets were used as signal amplifiers with excellent electrical properties. Specifically, CD63 aptamer attached Fe3O4 nanoprobes capture the target exosomes. MXene nanosheets modified with epithelial cell adhesion molecule (EpCAM) aptamer were tethered on the electrode surface to enhance the quantification of exosomes captured with the detection of remaining protein sites. With such a design, the proposed biosensor showed a wide linear range from 102 particles μL-1 to 107 particles μL-1 for sensing 4T1 exosomes, with a low detection limit of 43 particles μL-1. In addition, this sensing platform can determine four different tumor cell types (4T1, Hela, HepG2, and A549) using surface proteins corresponding to aptamers 1 and 2 (CD63 and EpCAM) and showcases good specificity in serum samples. These preliminary results demonstrate the feasibility of establishing a sensitive, accurate, and inexpensive electrochemical sensor for detecting exosome concentrations and species. Moreover, they provide a significant reference for exosome applications in clinical settings, such as liquid biopsy and early cancer diagnosis.
Collapse
Affiliation(s)
- Linlin Zhuang
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
- Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Qiannan You
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
- Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Xue Su
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
- Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Zhimin Chang
- Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Mingfeng Ge
- Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Qian Mei
- Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Li Yang
- Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China
| | - Wenfei Dong
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
- Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Li Li
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
- Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| |
Collapse
|
32
|
Sohrabi H, Maleki F, Khaaki P, Kadhom M, Kudaibergenov N, Khataee A. Electrochemical-Based Sensing Platforms for Detection of Glucose and H 2O 2 by Porous Metal-Organic Frameworks: A Review of Status and Prospects. BIOSENSORS 2023; 13:347. [PMID: 36979559 PMCID: PMC10046199 DOI: 10.3390/bios13030347] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 03/01/2023] [Accepted: 03/02/2023] [Indexed: 06/18/2023]
Abstract
Establishing enzyme-free sensing assays with great selectivity and sensitivity for glucose and H2O2 detection has been highly required in biological science. In particular, the exploitation of nanomaterials by using noble metals of high conductivity and surface area has been widely investigated to act as selective catalytic agents for molecular recognition in sensing platforms. Several approaches for a straightforward, speedy, selective, and sensitive recognition of glucose and H2O2 were requested. This paper reviews the current progress in electrochemical detection using metal-organic frameworks (MOFs) for H2O2 and glucose recognition. We have reviewed the latest electrochemical sensing assays for in-place detection with priorities including straightforward procedure and manipulation, high sensitivity, varied linear range, and economic prospects. The mentioned sensing assays apply electrochemical systems through a rapid detection time that enables real-time recognition. In profitable fields, the obstacles that have been associated with sample preparation and tool expense can be solved by applying these sensing means. Some parameters, including the impedance, intensity, and potential difference measurement methods have permitted low limit of detections (LODs) and noticeable durations in agricultural, water, and foodstuff samples with high levels of glucose and H2O2.
Collapse
Affiliation(s)
- Hessamaddin Sohrabi
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 51666-16471, Iran
| | - Fatemeh Maleki
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 51666-16471, Iran
| | - Pegah Khaaki
- Department of Biology, Tabriz Branch, Islamic Azad University, Tabriz 51666-16471, Iran
| | - Mohammed Kadhom
- Department of Environmental Science, College of Energy and Environmental Science, Alkarkh University of Science, Baghdad 10081, Iraq
| | - Nurbolat Kudaibergenov
- Department of Chemistry and Chemical Technology, Al-Farabi Kazakh National University, Al-Farabi 71, Almaty 050038, Kazakhstan
| | - Alireza Khataee
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 51666-16471, Iran
- Department of Environmental Engineering, Faculty of Engineering, Gebze Technical University, 41400 Gebze, Turkey
| |
Collapse
|
33
|
Wei C, Wang Z, Li S, Li T, Du X, Wang H, Liu Q, Yu Z. Hierarchical copper-based metal-organic frameworks nanosheet assemblies for electrochemical ascorbic acid sensing. Colloids Surf B Biointerfaces 2023; 223:113149. [PMID: 36706480 DOI: 10.1016/j.colsurfb.2023.113149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 01/07/2023] [Accepted: 01/15/2023] [Indexed: 01/18/2023]
Abstract
Noninvasive human health monitoring requires the development of efficient electrochemical sensors for the quantitative analysis of infinitesimal biomolecules. In this work, we reported a novel hierarchical nanosheet assemblies (HSA) of copper-based metal-organic frameworks (MOFs) as an electrochemical sensor for ascorbic acid (AA) detection. Copper 1,4-benzenedicarboxylate (CuBDC) HSA was constructed by three steps of in situ growth on stone paper, including hydrolysis, anion exchange, and heteroepitaxy growth. The monodispersed two-dimensional MOFs nanosheet units were aligned in an orderly manner and arranged into three-dimensional hierarchical assemblies. The CuBDC HSA-based AA sensor displayed a high sensitivity of 396.8 μA mM-1 cm-2 and a low detection limit of 0.1 μM. Excellent selectivity, stability and reproducibility were also obtained. Benefiting from the advantages of ultrathin nanosheets and nature-inspired hierarchy, this unique architecture facilitated reactant dispersion and maximized the accessible active sites and charge-transport capability and thus had superior catalytic ability for the electro-oxidation of ascorbic acid compared to bulk MOFs. Moreover, the CuBDC HSA sensor performed AA level detection in juice samples with acceptable accuracy and verified the feasibility for sweat AA sensing. This novel MOFs architecture holds great potential as an electrochemical sensor to detect AA for noninvasive human health monitoring in the future.
Collapse
Affiliation(s)
- Chenhuinan Wei
- Hubei Provincial Key Laboratory of Green Materials for Light Industry, School of Materials and Chemical Engineering, Hubei University of Technology, Wuhan 430068, PR China; New Materials and Green Manufacturing Talent Introduction and Innovation Demonstration Base, Hubei University of Technology, Wuhan, PR China.
| | - Zhuo Wang
- Hubei Provincial Key Laboratory of Green Materials for Light Industry, School of Materials and Chemical Engineering, Hubei University of Technology, Wuhan 430068, PR China
| | - Shanyu Li
- Hubei Provincial Key Laboratory of Green Materials for Light Industry, School of Materials and Chemical Engineering, Hubei University of Technology, Wuhan 430068, PR China
| | - Tao Li
- Hubei Provincial Key Laboratory of Green Materials for Light Industry, School of Materials and Chemical Engineering, Hubei University of Technology, Wuhan 430068, PR China
| | - Xinran Du
- Hubei Provincial Key Laboratory of Green Materials for Light Industry, School of Materials and Chemical Engineering, Hubei University of Technology, Wuhan 430068, PR China
| | - Huihu Wang
- Hubei Provincial Key Laboratory of Green Materials for Light Industry, School of Materials and Chemical Engineering, Hubei University of Technology, Wuhan 430068, PR China; New Materials and Green Manufacturing Talent Introduction and Innovation Demonstration Base, Hubei University of Technology, Wuhan, PR China
| | - Qiming Liu
- Key Laboratory of Ariticial Micro, and Nano-structures of Ministry of Education, School of Physics and Technology, Wuhan University, Wuhan 430072, PR China
| | - Ziyang Yu
- Hubei Key Laboratory of Optical Information and Pattern Recognition, School of Optical Information and Energy Engineering, Wuhan Institute of Technology, Wuhan 430205, PR China.
| |
Collapse
|
34
|
Wu CW, Chiang MH, Lee CL. Pd@Au Core-Shell Octahedral, Truncated Octahedral, and Cubic Nanocrystals as Nonenzymatic Glucose Sensors for Drinks. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023]
|
35
|
Dey B, Sarkhel G, Choudhury A. Facile synthesis of copper MOF/carbon nanofiber nanocomposite paper for electrochemical detection of toxic 4-nitrophenol. JOURNAL OF MACROMOLECULAR SCIENCE PART A-PURE AND APPLIED CHEMISTRY 2023. [DOI: 10.1080/10601325.2023.2177169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
Affiliation(s)
- Baban Dey
- Department of Chemical Engineering, Birla Institute of Technology, Ranchi, India
| | - Gautam Sarkhel
- Department of Chemical Engineering, Birla Institute of Technology, Ranchi, India
| | - Arup Choudhury
- Department of Chemical Engineering, Birla Institute of Technology, Ranchi, India
| |
Collapse
|
36
|
Wei Y, Hui Y, Lu X, Liu C, Zhang Y, Fan Y, Chen W. One-pot preparation of NiMn layered double hydroxide-MOF material for highly sensitive electrochemical sensing of glucose. J Electroanal Chem (Lausanne) 2023. [DOI: 10.1016/j.jelechem.2023.117276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
|
37
|
Alameri AA, Sanaan Jabbar H, Altimari US, Sultonov MM, Mahdi AB, Solanki R, Shaker Shafik S, Sivaraman R, Aravindhan S, Hadi JM, Mahmood Saleh M, Mustafa YF. Advances in Biosensing of Chemical Food Contaminants Based on the MOFs-Graphene Nanohybrids. Crit Rev Anal Chem 2022; 54:2166-2182. [PMID: 36580293 DOI: 10.1080/10408347.2022.2160923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Food safety issue is becoming an international challenge for human health owing to the presence of contaminants. In this context, reliable, rapid, and sensitive detecting technology is extremely demanded to establish food safety assurance systems. MOFs (Metal-organic frameworks) are a new type of porous crystalline material with particular physical and chemical characteristics presented in food safety requirements. (Bio)sensors driven MOF materials have emerged as a promising alternative and complementary analytical techniques, owing to their great specific area, high porosity, and uniform and fine-tunable pore buildings. Nevertheless, the insufficient stability and electrical conductivity of classical MOFs limit their utilization. Employing graphene-derived nanomaterials with high functional elements as patterns for the MOF materials not only improves the structural instability and poor conductivity but also impedes the restacking and aggregation between graphene layers, thus significantly extending the MOFs application. A review of MOFs-graphene-based material used in food contamination detection is urgently needed for encouraging the advance of this field. Herein, this paper systematically outlines current breakthroughs in MOF-graphene-based nanoprobes, outlines their principles, and illustrates their employments in identifying mycotoxins, heavy metal ions, pathogens, antibiotics, and pesticides, referring to their multiplexing and sensitivity ability. The challenges and limitations of applying MOF-graphene composite for precise and efficient assessment of food were also debated. This paper would maybe offer some inspired concepts for an upcoming study on MOF-based composites in the food security context.
Collapse
Affiliation(s)
- Ameer A Alameri
- Department of Chemistry, Faculty of Science, University of Babylon, Babylon, Iraq
| | - Hijran Sanaan Jabbar
- Department of Chemistry, College of Science, Salahaddin University-Erbil, Iraq
- Department of Medical Laboratory Science, College of Health Sciences, Lebanese French University, Erbil, Kurdistan Region, Iraq
| | | | - Marat Mirzaevich Sultonov
- Jizzakh State Pedagogical Institute, Department of Chemistry and Teaching Methods, Jizzakh, Uzbekistan
| | - Ahmed B Mahdi
- Anesthesia Techniques Department, Al-Mustaqbal University College, Babylon, Iraq
| | - Reena Solanki
- Department of Chemistry, Dr APJ Abdul Kalam University, Indore, India
| | - Shafik Shaker Shafik
- Experimental Nuclear Radiation Group, Scientific Research Center, Al-Ayen University, Nasiriyah, Iraq
| | - R Sivaraman
- Dwaraka Doss Goverdhan Doss Vaishnav College, University of Madras, Chennai, India
| | - Surendar Aravindhan
- Department of Pharmacology, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Chennai, India
| | - Jihad M Hadi
- Nursing Department, College of Nursing, University of Human Development, Kurdistan Regional Government, Sulaimani, Iraq
| | - Marwan Mahmood Saleh
- Department of Biophysics, College of Applied Sciences, University of Anbar, Iraq
| | - Yasser Fakri Mustafa
- Department of Pharmaceutical Chemistry, College of Pharmacy, University of Mosul, Mosul, Iraq
| |
Collapse
|
38
|
Ultrafast construction of 3D ultrathin NiCo-LDH@Cu heteronanosheet array by plasma magnetron sputtering for non-enzymatic glucose sensing in beverage and human serum. Food Chem 2022; 393:133399. [PMID: 35679705 DOI: 10.1016/j.foodchem.2022.133399] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Revised: 05/08/2022] [Accepted: 06/02/2022] [Indexed: 11/21/2022]
Abstract
In this work, a 3D ultra-thin NiCo-LDH nanosheet array coated Cu nanoparticles on carbon cloth (NiCo-LDH@Cu NSA/CC) was ultrafast synthesized by plasma magnetron sputtering for the first time. This method has low toxicity and is easy to operate. As a durable and efficient 3D heteronanoarray electrocatalyst for glucose detection, NiCo-LDH@Cu NSA/CC has higher stable conductivity and faster electron transport rate than NiCo-LDH NSA/CC and Cu nanoparticles, which work through synergistic effect to form a high-performance sensing platform. The NiCo-LDH@Cu NSA/CC heteronanosheet structure has good electrocatalytic performance for glucose oxidation, with the sensitivity of the two linear ranges (0.001-1 mmol L-1 and 1-6 mmol L-1) being 9710 μA L mmol-1 cm-2 and 4870 μA L mmol-1 cm-2, respectively, and the detection limit (LOD) is 157 nmol L-1 (S/N = 3). The sensor has been successfully applied to detect glucose in beverages and serum.
Collapse
|
39
|
Wang Z, Zhang M, Song Z, Yaseen M, Huang Z, Wang A, Guisheng Z, Shao S. Synergistic catalytic enhancement of metal-organic framework derived nanoarchitectures decorated on graphene as a high-efficiency bifunctional electrocatalyst for methanol oxidation and oxygen reduction. J Colloid Interface Sci 2022; 624:88-99. [PMID: 35660914 DOI: 10.1016/j.jcis.2022.05.094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Revised: 05/15/2022] [Accepted: 05/16/2022] [Indexed: 10/18/2022]
Abstract
Designing highly efficient, long-lasting, and cost-effective cathodic and anodic functional materials as a bifunctional electrocatalyst is essential for overcoming the bottleneck in fuel cell development. Herein, a novel two-step synthesis strategy is developed to synthesize metal-organic framework (MOF) derived nitrogen-doped carbon (NC) with improved spatial isolation and a higher loading amount of cobalt (Co) and nickel carbide (Ni3C) nanocrystal decorated on graphene (denoted as Co@NC-Ni3C/G). Benefiting from multiple active sites of high N-doping level, uniform dispersion of Co and Ni3C nanocrystals, and a large active area of graphene, the Co@NC-Ni3C/G hybrids exhibit excellent methanol oxidation reaction (MOR) and oxygen reduction reaction (ORR) efficiency in an alkaline environment. For MOR, the optimized Co@NC-Ni3C/G-350 catalyst achieved a current density of 44.8 mA cm-2 at an applied potential of 1.47 V (V vs. RHE), which is significantly higher than Co@NC-Ni3C (42.07 mA cm-2) and Co@NC (24.1 mA cm-2) in 0.5 M methanol + 1.0 M KOH solutions. In addition, during the CO retention test, the Co@NC-Ni3C/G-350 catalyst exhibits excellent CO tolerance capacity. Excitingly, the as-prepared Co@NC-Ni3C/G-350 hybrid exhibits significantly improved ORR catalytic efficiency in terms of positive onset and half-wave potential (Eonset = 0.90 V, E1/2 = 0.830 V vs. RHE), small Tafel slope (34 mV dec-1) and excellent durability (only reduced 0.016 V after 5000 s test). This work provides new insights into MOF-derived functional nanomaterials for anode and cathode co-catalysts for methanol fuel cells.
Collapse
Affiliation(s)
- Zhuokai Wang
- School of Chemistry and Chemical Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China
| | - Mingmei Zhang
- School of Chemistry and Chemical Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China.
| | - Zixiang Song
- School of Chemistry and Chemical Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China
| | - Maria Yaseen
- School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Zhiye Huang
- School of Chemistry and Chemical Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China
| | - An Wang
- School of Chemistry and Chemical Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China
| | - Zhu Guisheng
- School of Chemistry and Chemical Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China
| | - Shouyan Shao
- School of Chemistry and Chemical Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China
| |
Collapse
|
40
|
Lang X, Chu D, Wang Y, Ge D, Chen X. Defect Surface Engineering of Hollow NiCo 2S 4 Nanoprisms towards Performance-Enhanced Non-Enzymatic Glucose Oxidation. BIOSENSORS 2022; 12:823. [PMID: 36290962 PMCID: PMC9599600 DOI: 10.3390/bios12100823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 09/25/2022] [Accepted: 10/03/2022] [Indexed: 06/16/2023]
Abstract
Transition metal sulfides have been explored as electrode materials for non-enzymatic detection. In this work, we investigated the effects of phosphorus doping on the electrochemical performances of NiCo2S4 electrodes (P-NiCo2S4) towards glucose oxidation. The fabricated non-enzymatic biosensor displayed better sensing performances than pristine NiCo2S4, with a good sensitivity of 250 µA mM-1 cm-2, a low detection limit (LOD) of 0.46 µM (S/N = 3), a wide linear range of 0.001 to 5.2 mM, and high selectivity. Moreover, P-NiCo2S4 demonstrated its feasibility for glucose determination for practical sample testing. This is due to the fact that the synergetic effects between Ni and Co species, and the partial substitution of S vacancies with P can help to increase electronic conductivity, enrich binary electroactive sites, and facilitate surface electroactivity. Thus, it is found that the incorporation of dopants into NiCo2S4 is an effective strategy to improve the electrochemical activity of host materials.
Collapse
Affiliation(s)
- Xiaomin Lang
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing 211800, China
| | - Dandan Chu
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing 211800, China
| | - Yan Wang
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing 211800, China
| | - Danhua Ge
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing 211800, China
| | - Xiaojun Chen
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing 211800, China
- Jiangsu Key Laboratory of Molecular Biology for Skin Diseases and STIs, Nanjing 210042, China
| |
Collapse
|
41
|
Chu D, Wang Y, Li D, Chu XQ, Ge D, Chen X. Prism-like bimetallic (Ni-Co) alkaline carboxylate-based non-enzymatic sensor capable of exceptionally high catalytic activity towards glucose. Dalton Trans 2022; 51:15354-15360. [PMID: 36148531 DOI: 10.1039/d2dt02424a] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
In this study, we fabricated a novel non-enzymatic glucose sensor based on prism-like bimetallic alkaline carboxylate (CoNi-MIM). The morphology and structure of CoNi-MIM were carefully investigated by scanning electron microscopy (SEM), transmission electron microscopy (TEM), powder X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). The electrochemical glucose oxidation of the synthesized sensor was then explored by cyclic voltammetry (CV) and chronoamperometry in alkaline medium. It was found that CoNi-MIM is the optimal choice with a remarkably high sensitivity of 5024.4 μA mM-1 cm-2, low detection limit of 56.1 nM (S/N = 3), linear response of up to 14.3 mM and excellent selectivity compared to Co-MIM, CoFe-MIM and CoMn-MIM. Furthermore, the as-fabricated sensor demonstrated appreciable practicality for the determination of glucose in real samples. These results indicate that CoNi-MIM holds a good application prospect in non-enzymatic glucose sensing.
Collapse
Affiliation(s)
- Dandan Chu
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, P.R. China.
| | - Yan Wang
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, P.R. China.
| | - Dong Li
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, P.R. China.
| | - Xue-Qiang Chu
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, P.R. China.
| | - Danhua Ge
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, P.R. China.
| | - Xiaojun Chen
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, P.R. China. .,Jiangsu Key Laboratory of Molecular Biology for Skin Diseases and STIs, Nanjing, 210042, P.R. China
| |
Collapse
|
42
|
Liu J, Yang S, Shen J, Fa H, Hou C, Yang M. Conductive metal-organic framework based label-free electrochemical detection of circulating tumor DNA. Mikrochim Acta 2022; 189:391. [PMID: 36138259 DOI: 10.1007/s00604-022-05482-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 08/29/2022] [Indexed: 11/29/2022]
Abstract
An ultrasensitive electrochemical biosensor was designed for the rapid label-free detection of circulating tumor DNA (ctDNA, EGFR 19 Dels for non-small cell lung cancer, NSCLC). We linked the highly conjugated tricatecholate, 2,3,6,7,10,11-hexahydroxytriphenylene (HHTP) with Ni(II) ions into the two-dimensional porous conductive metal-organic frameworks (MOFs), which is termed Ni-catecholates (Ni-CAT). Then, the AuNPs/Ni-catecholates/carbon black/polarized pencil graphite electrode (AuNPs/Ni-CAT/CB/PPGE) was obtained by electrodeposition of AuNPs on the surface of PPGE modified with Ni-CAT/CB composite materials. The AuNPs/Ni-CAT/CB/PPGE were used for label-less detection of ctDNA, with a total detection time of only 30 min. Under optimal detection conditions, the AuNPs/Ni-CAT/CB/PPGE sensor exhibited excellent detection performance with good linear response to ctDNA over a wide concentration range and the detection limit down to the femtomolar level. The sensor was applied to the determination of ctDNA in serum samples with high sensitivity. This simple, efficient, and expeditious method has practical value in liquid biopsy of ctDNA and has potential for development in early detection, treatment, and prognosis of tumors. Herein, an ultrasensitive electrochemical biosensor was designed for the rapid label-free detection of ctDNA (EGFR 19 Dels for non-small cell lung cancer, NSCLC). We linked the highly conjugated tricatecholate, 2,3,6,7,10,11-hexahydroxytriphenylene (HHTP) with Ni(II) ions into the two-dimensional porous conductive metal-organic frameworks (MOFs), which is termed as Ni-catecholates (Ni-CAT). Then, the AuNPs/Ni-catecholates/carbon black/polarized pencil graphite electrode (AuNPs/Ni-CAT/CB/PPGE) was obtained by electrodeposition of AuNPs on the surface of PPGE modified with Ni-CAT/CB composite materials. The AuNPs/Ni-CAT/CB/PPGEs were used for label-less detection of ctDNA, with a total detection time of only 30 min. Under optimal detection conditions, the AuNPs/Ni-CAT/CB/PPGE sensor exhibited excellent detection performance with good linear response to ctDNA in the concentration range of 1 × 10-15 M to 1 × 10-6 M and with a detection limit as low as 0.32 fM. The sensor was applied for determination of ctDNA in serum samples and gave high sensitivity. This simple, efficient and expeditious method has practical value in liquid biopsy of ctDNA and has potential for development in early detection, treatment and prognosis of tumors.
Collapse
Affiliation(s)
- Juan Liu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, People's Republic of China
| | - Siyi Yang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, People's Republic of China
| | - Jinhui Shen
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, People's Republic of China
| | - Huanbao Fa
- College of Chemistry and Chemical Engineering, Chongqing University, Chongqing, 400044, People's Republic of China
| | - Changjun Hou
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, People's Republic of China. .,College of Bioengineering, Chongqing University, Chongqing, 400044, People's Republic of China.
| | - Mei Yang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, People's Republic of China. .,College of Bioengineering, Chongqing University, Chongqing, 400044, People's Republic of China.
| |
Collapse
|
43
|
Bimetallic FeMn@C derived from Prussian blue analogue as efficient nanozyme for glucose detection. Anal Bioanal Chem 2022; 414:7773-7782. [PMID: 36066578 DOI: 10.1007/s00216-022-04310-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Accepted: 08/29/2022] [Indexed: 11/01/2022]
Abstract
In recent decades, nanomaterial-based artificial enzymes called nanozymes have received more and more attention and have been applied in biological, chemical, medical, and other fields. In this work, bimetallic FeMn@C was synthesized by calcination from the Prussian blue analogue. The synthesized bimetallic FeMn@C exhibits efficient peroxidase-like activity. The effect of Mn doping amount, catalytic kinetics, and mechanism of FeMn@C nanozyme was further studied in detail. The results show that the peroxidase-like activity of bimetallic FeMn@C is nearly 16 times higher than that of single-metal Fe@C. The peroxidase-like activity of FeMn@C originates from its production of radicals. Compared with natural enzymes, FeMn@C nanozyme has a better affinity for the substrates. Besides, FeMn@C nanozyme has better stability than natural enzymes. Because of its strong magnetism, FeMn@C nanozyme can be recycled easily and exhibits excellent recycling performance. Based on the good affinity of FeMn@C for H2O2, a rapid and selective colorimetric assay for glucose detection is constructed, with a wide linear range of 0.01-0.75 mM and low detection limit of 4.28 µM. This sensor has been successfully applied to the determination of glucose in fruit juice, showing good selectivity and accuracy. The synthesis of bimetallic FeMn@C provides a feasible way to design nanozymes with excellent catalytic activity, high stability, and easy separation.
Collapse
|
44
|
Wang Z, Liu Y, Cheng Y, Men YL, Liu P, Zhang L, Dai B, Pan YX. Fast and efficient electrocatalytic oxidation of glucose triggered by Cu2O-CuO nanoparticles supported on carbon nanotubes. Front Chem 2022; 10:998812. [PMID: 36118309 PMCID: PMC9475138 DOI: 10.3389/fchem.2022.998812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Accepted: 08/05/2022] [Indexed: 12/03/2022] Open
Abstract
Electrocatalytic glucose oxidation reaction (GOR) is the key to construct sophisticated devices for fast and accurately detecting trace glucose in blood and food. Herein, a noble-metal-free Cu/C-60 catalyst is fabricated by supporting Cu2O-CuO nanoparticles on carbon nanotubes through a novel discharge process. For GOR, Cu/C-60 shows a sensitivity as high as 532 μA mM−1 cm−2, a detection limit as low as 1 μM and a steady-state response time of only 5.5 s. Moreover, Cu/C-60 has outstanding stability and anti-interference ability to impurities. The synergistic effect of Cu2O-CuO could improve the adsorption and conversion of glucose, thus enhancing GOR performance. By using Cu/C-60, we fabricate a three-electrode chip. A portable and compact electrochemical system is constructed by connecting the three-electrode chip with Cu/C-60 to an integrated circuit board and a mobile phone for recording and displaying data. The portable and compact electrochemical system results in a GOR sensitivity of 501 μA mM−1 cm−2, which is close to the data measured on the bloated electrochemical workstation. The detection limit of the portable and compact electrochemical system in GOR is 50 μM. This is higher than those obtained on the bloated electrochemical workstation, but is much lower than the common blood glucose concentration of human body (>3 mM). This demonstrates the accuracy, reasonability and applicability of the portable and compact electrochemical system. The results of the present work are helpful for fabricating fast, efficient and portable devices for detecting trace amount of glucose in blood and food.
Collapse
Affiliation(s)
- Zhongting Wang
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yi Liu
- Department of Chemical Engineering, School of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yongxi Cheng
- Beijing Institute of Aerospace Testing Technology, Beijing, China
| | - Yu-Long Men
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Peng Liu
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Lei Zhang
- Department of Vascular Surgery, Changhai Hospital, Naval Medical University, Shanghai, China
- *Correspondence: Yun-Xiang Pan, ; Bin Dai, ; Lei Zhang,
| | - Bin Dai
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
- *Correspondence: Yun-Xiang Pan, ; Bin Dai, ; Lei Zhang,
| | - Yun-Xiang Pan
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Department of Chemical Engineering, School of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, Shanghai, China
- *Correspondence: Yun-Xiang Pan, ; Bin Dai, ; Lei Zhang,
| |
Collapse
|
45
|
Li JJ, Yin L, Wang ZF, Jing YC, Jiang ZL, Ding Y, Wang HS. Enzyme-immobilized metal-organic frameworks: From preparation to application. Chem Asian J 2022; 17:e202200751. [PMID: 36029234 DOI: 10.1002/asia.202200751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 08/27/2022] [Indexed: 11/09/2022]
Abstract
As a class of widely used biocatalysts, enzymes possess advantages including high catalytic efficiency, strong specificity and mild reaction condition. However, most free enzymes have high requirements on the reaction environment and are easy to deactivate. Immobilization of enzymes on nanomaterial-based substrates is a good way to solve this problem. Metal-organic framework (MOFs), with ultra-high specific surface area and adjustable porosity, can provide a large space to carry enzymes. And the tightly surrounded protective layer of MOFs can stabilize the enzyme structure to a great extent. In addition, the unique porous network structure enables selective mass transfer of substrates and facilitates catalytic processes. Therefore, these enzyme-immobilized MOFs have been widely used in various research fields, such as molecule/biomolecule sensing and imaging, disease treatment, energy and environment protection. In this review, the preparation strategies and applications of enzymes-immobilized MOFs are illustrated and the prospects and current challenges are discussed.
Collapse
Affiliation(s)
- Jia-Jing Li
- China Pharmaceutical University, Pharmaceutical analysis, CHINA
| | - Li Yin
- China Pharmaceutical University, Pharmaceutical analysis, CHINA
| | - Zi-Fan Wang
- China Pharmaceutical University, Pharmaceutical analysis, CHINA
| | - Yi-Chen Jing
- China Pharmaceutical University, Pharmaceutical analysis, CHINA
| | - Zhuo-Lin Jiang
- China Pharmaceutical University, Pharmaceutical analysis, CHINA
| | - Ya Ding
- China Pharmaceutical University, Pharmaceutical analysis, CHINA
| | - Huai-Song Wang
- China Parmaceutical University, Pharmaceutical analysis, Department of Pharmaceutical Analysis, China Pharmaceutical University, Nanjing Jiangsu, CHINA
| |
Collapse
|
46
|
Zha X, Yang W, Shi L, Li Y, Zeng Q, Xu J, Yang Y. Morphology Control Strategy of Bimetallic MOF Nanosheets for Upgrading the Sensitivity of Noninvasive Glucose Detection. ACS APPLIED MATERIALS & INTERFACES 2022; 14:37843-37852. [PMID: 35947783 DOI: 10.1021/acsami.2c10760] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The precise measurement of glucose level is significant for the health management of the human body. However, the existing sensitive materials and detection methods for glucose are less satisfying for practical applications. Herein, an ultrathin reticular two-dimensional nanosheets array composed of trimesic acid (H3BTC)-based bimetal metal-organic frameworks (MOFs) and carbon cloth (CC), which is constructed through a morphology control strategy, is reported for glucose sensing. Meanwhile, this nonmoving sweat glucose sensor based on a NiCo-BTC/CC electrode has been successfully prepared by a screen printing method. Benefiting from the regular and ultrathin nanosheets array, the NiCo-BTC/CC electrode has an excellent sensitivity of 2701.29 μA mM-1 cm-2, which is about 2.4 times that of its unregulated counterpart (1127.85 μA mM-1 cm-2) in the linear range 5-205 μM. In addition, an ultralow detection limit (0.09 μM, S/N = 3) and good selectivity of NiCo-BTC/CC were also obtained. The high sensitivity of the glucose sensor based on NiCo-BTC/CC electrode is 0.174 μA μM-1 (50-1000 μM). Remarkably, the preciously designed sensor is used to detect glucose concentration in sweat with a noninvasive mode, and the results are basically consistent with those of a commercial glucose device with an invasive mode. This research exhibits potential methodology for the morphology design of bimetallic MOFs nanosheets to achieve a high accuracy rate and noninvasive and timeless measurement of a glucose sensor.
Collapse
Affiliation(s)
- Xiaoting Zha
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
| | - Wenyao Yang
- Chongqing Engineering Research Center of New Energy Storage Devices and Applications, Chongqing University of Arts and Sciences, Chongqing 402160, China
| | - Liuwei Shi
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
| | - Yi Li
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
| | - Qi Zeng
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
| | - Jianhua Xu
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
| | - Yajie Yang
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
- Yangtze Delta Region Institute (Huzhou), University of Electronic Science and Technology of China, Huzhou 313001, China
| |
Collapse
|
47
|
Chen J, Huang X, Ye R, Huang D, Wang Y, Chen S. Fabrication of a novel electrochemical sensor using conductive MOF Cu-CAT anchored on reduced graphene oxide for BPA detection. J APPL ELECTROCHEM 2022. [DOI: 10.1007/s10800-022-01735-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
|
48
|
Shu H, Peng S, Lai T, Cui X, Ren J, Chen T, Xiao X, Wang Y. Nickel foam electrode decorated with Fe-CdIn2O4 nanoparticles as an effective electrochemical sensor for non-enzymatic glucose detection. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
49
|
Chen T, Zhao P, Li J, Sun Z, Huang W. Construction of a novel Co-based coordination polymer and its study of non-enzymatic glucose sensors. J SOLID STATE CHEM 2022. [DOI: 10.1016/j.jssc.2022.123115] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
50
|
Cheng L, Wu RJ, Li YM, Ren H, Ji CY, Li WJ. Single-chain polymer nanoparticles-encapsulated chiral bifunctional metal-organic frameworks for asymmetric sequential reactions. INORG CHEM COMMUN 2022. [DOI: 10.1016/j.inoche.2022.109577] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|